EGM1100C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification
|
|
- Reginald Gray
- 5 years ago
- Views:
Transcription
1 EGMC Compact Electromagnetic Flowmeter GENERA MAGMAX EGMC is the compact type electromagnetic flowmeter with a converter EGC mounted integrally on a primary head EGS lined with fluorocarbon resin PFA. MAGMAX EGMC enjoys low cost and high performance thanks to the advanced converter, and the light weight and compact primary head. The flowmeter is equipped with empty flow detection and status monitoring functions of primary head using the enhanced self-diagnosis unit. ined with high-quality PFA and equipped with Hastelloy C for electrodes, MAGMAX EGMC has 8 sizes from mm to 5 mm. In addition to water services such as city water and waste water treatment, it is widely used for various chemical processes and utilities. FEATURES The high-quality and clear PFA reinforced by the punched plates assures the anti-corrosion, anti-erosion and anti-permeation. High accuracy of ±.5% of reading. High speed data processing for quick response. Suitable for batch process control and pulsating flow. The extendable excitation system allows applications to much fluid noise such as slurry. The CD with backlight provides to 3 lines of versatile indication. Equipped with a quick setup function to readily respond to changed flow range, pulse rate, etc. The push buttons allow you to alter the settings without removing the cover of conversion section. khz high-speed pulse output. Capable of responding to short batch processes. ized high-performance functions such as bi-directional measurement, double ranges and status outputs including flow rate alarms. STANDARD SPECIFICATION General Specification Excitation Nominal size : Square wave :, 5, 25,, 5, 8,, 5 mm Measuring range : Flow velocity Min. to.3 m/s Max. to 2 m/s Flow rate Min. to.85 m 3 /h equivalent to minimum flow rate of size mm Max. to 73 m 3 /h equivalent to maximum flow rate of size 5 mm Protection class : IP/7 (IEC 529) Materials of body Measuring tube : Stainless steel SS3 Primary head housing : Sizes to mm Cast iron * Sizes 5 to 5 mm Carbon steel * Converter housing : Aluminum alloy * Converter cover : Aluminum alloy * Indicator water protection sheet : Polyester * Finished with anti-corrosion painting. Materials of wet parts : iner : PFA Electrode : Hastelloy C22 : Stainless steel SS3 [] seal : FPM/FKM Applied only for nominal size and 5mm * 2 *2 The earth rings of flowmeters 25 mm to 5 mm have no special sealing materials. The gasket face of lining materials works as sealing. Painting : Siloxane coating Color : Grey (Primary head housing/converter housing) Jade green (Converter cover)
2 EGMC Compact Electromagnetic Flowmeter Cable entry : 2 G/2 female thread or 2 /2 NPT female thread or 2 M2 with watertight glands (Option : atertight glands for G/2) Supply voltage : to 23V AC (85 to 253V AC) 2V DC ( to 3V) Supply frequency : 8 to 3Hz (AC) Power consumption : Approx. 8 VA AC Approx. DC Ambient temp. : - to 5 C for operation when fluid temperature 2 C - to 7 C for storage Grounding : Grounding resistance must be less than Ω. Process connection : afer type, sandwiched between following flanges Flanges : JISK, 2K ASME class 5, 3 DIN PN, Note : The flowmeters can be mounted physically on JIS2K or ASME class 3 flanges. However, the maximum allowable pressure of the flowmeters is. MPa. FUID SPECIFICATION Temperature : -25 to 2 C* Pressure : Pa abs to. MPa Conductivity : μs/cm or more 2 μs/cm or more is required for water Indication and Output Specification Indicator : Dot matrix CD (ith backlight) 28 pixels (59 3mm) Indication function : Changeover (2 screens) One to three lines are displayed at one screen. Contents of indication ; Flow rate, velocity, total flow, conductivity, and coil temperature Current output : to 2mA DC (Max. 22mA at burn out error mode) Internal power supply : ess than 75ohms (oad resistance) External power supply : ess than 32V DC (External voltage) Pulse output Open collector output Rating : ess than 32V DC, 2mA ( khz) ess than ma ( Hz) Residual voltage: ess than.5 VDC at ma eak current: ess than.5 ma at 2 VDC Pulse rate 2 to 3,, pulse/h (.5Hz to khz) Pulse width One of the following selectable ) Automatic : Pulse width by which duty factor to be 5% at full scale 2) Duty factor : fixed 3) Free setting ;.5 to 2ms Status output Open collector output Rating : ess than 32V DC, ma Max. Residual voltage: ess than.5 VDC at ma eak current: ess than.5 ma at 2 VDC Contents of output One of the following selectable: ) No status output ( factory setting) 2) Identification of flow direction 3) Over range ) Error 5) Flow alarm ) Identification of range (For double range measurement) 7) Empty pipe detection Description of input and output terminal Terminal A (A, A / A) C (C, C) D (D, D) setup Current output Status output Pulse output Switchover by reprogramming Status output ow flow cutoff Current output, Pulse output, Indicator (Separate setting is possible.) Setting value :. to 2.% FS Setting value () : Current output, Pulse output ; ON %, OFF 2% FS Indicator ; ithout low flow cutoff Damping time constant Current output, Pulse output, Indicator (Separate setting is possible.) Setting value :. to.s Setting value () : Current output, Indicator ; s Pulse output ; Damping time constant Isolation of input and output Each circuit of power supply, electrode input, terminal A, terminal C, and terminal D are isolated. 2 TOKYO KEISO CO., TD. TG-F55-5E
3 EGMC Compact Electromagnetic Flowmeter Functions Customer s free measuring unit setting function Volume (or mass) and time unit in 7 characters can be created. Automatic zero adjustment function Zero adjustment is automatically conducted at "ZERO ADJUST MODE" (Subject to zero flow) Bi-directional flow measurement function A flow-direction distinction signal is outputted in state output and current. Double range measurement function Possible range setting range ratio : 2 to :.25 (Setting range of low range : 5 to 8% of high range) Range selection ; Automatic Excitation current frequency switching function mode : / of supply frequency () Special frequency mode : /5 to /2 times of supply frequency ( * 3) Self-diagnosis function The following conditions are indicated by error message; Functional diagnosis : Coil disconnection, CPU, Memory, Software, Output module, and Output connection Status diagnosis : Empty pipe detection, Over range, Counter over flow, and Power fail detection Memory save function for power fail Operation parameters and totalization figures are stored for more than years by EEPROM (Non volatile memory). Testing function Simulating output function for current, pulse output and status output are integrated. Current output test : Arbitrary output (. to 22. ma) Pulse output test : Arbitrary output (Hz to khz) Status output test : On / Off Push button setting function The push buttons allow you to alter the settings without removing the cover of conversion section. HART communication Accuracy ( * ) Indication and Pulse output For velocity m/s : ±.5% of reading For velocity < m/s : ±.% of reading velocity error ±.m/s Error ±% of reading Velocity (m/s) Current output : Additional error of ±.ma be added to the accuracy of indication or pulse output. (*) Basis condition Fluid : ater Fluid temperature : to 3ºC Conductivity : 5μS/cm or more Supply voltage : Rated voltage ±2% Ambient temperature : 8 to 28ºC Upstream / Downstream pipe length : D / 2D (D: Diameter) arm-up time : About minutes Measuring time : s FO RANGE Nominal size mm Possible setting range m 3 /h Minimum flow rate at flow velocity to.3 m/s Maximum flow rate at flow velocity to 2 m/s to.89 to to.9 to to.53 to 2.2 to.3 to to 2.3 to to 5.3 to 27 to 8.9 to to 9. to 73 (*3) It can be changed for every application, such as slurry and a pulsating flow. TG-F55-5E TOKYO KEISO CO., TD. 3
4 MAGMAX EGMC Compact Electromagnetic Flowmeter DIMENSIONS Version type Nominal size mm, 5mm Nominal size 25mm, mm Nominal size 5 mm, 8 mm, mm, 5 mm 23 Flow direction () TOKYO KEISO CO., TD. TG-F55-5E
5 MAGMAX EGMC Compact Electromagnetic Flowmeter DIMENSIONS Version 2 type Nominal size mm, 5mm Nominal size 25mm, mm Nominal size 5 mm, 8 mm, mm, 5 mm 23 Nominal size mm TG-F55-5E Dimensions mm Note The face to face dimensions of flowmeters and 5 mm include the thickness of earth rings. The earth rings are fixed to the primary head. Note 2 The face to face dimensions of flowmeters from 25 to 5 mm also include the thickness of earth rings. Insert the earth rings between the primary head and mating flanges when mounting flowmeter as the earth rings are not fixed to the primary head. The face to face dimensions of the primary head itself is "-" mm without earth rings where total thickness of 2 pieces of earth rings is "3 x 2 = " mm Approx. Mass kg TOKYO KEISO CO., TD. 5
6 EGMC Compact Electromagnetic Flowmeter EECTRICA CONNECTION N PE C C D D S A A A Pw Sp Pp la lp Mark lp la Sp Pp Pw Terminal A A A A C C D D () N () PE (FE) S Polarity () () Description Current output when power is supplied externally. Current output when power is supplied internally. Status output by open collector Pulse output by open collector AC or DC power supply The ( ) show DC power. Grounding for power supply. The (FE) shows DC power. Grounding for shielded wire Terminal type : Spring clamp terminal Applicable core size :.5 to 2.5mm 2 Mounting direction of indicator Version type () Version 2 type The flow directions can be set in the opposite direction by changing the setting data. TOKYO KEISO CO., TD. TG-F55-5E
7 EGMC Compact Electromagnetic Flowmeter MODE AND SPECIFICATION CODE Nominal size : to 5 mm Model : EGMC Primary head spec. code V N 7 Primary head code V N 7 Nominal size Process connection Type material (Seal material for earth ring) Calibration Special feature 5 8 B C E F H N 3 N 3 K 9 2 Description afer type, PFA liner, Hastelloy C22 electrodes Always Connection flange size mm 5mm 25mm mm 5mm 8mm mm 5mm or 5A 5A 25A A 5A 8A A 5A /2" /2" " -/2" 2" 3" " " afer type, sandwiched between 2 flanges Always Compact type, integrated with converter EGC Always Stainless steel SS3 (FPM/FKM seal) Stainless steel SS3 For size and 5mm For size 25 to 5mm 2 Blank Z Other Always calibration Always 2 None Involved * Converter spec. code V N 3 Converter code V N 3 Type Power supply Cable entry Housing Orientation of indicator installation Output type Special feature A Blank Z Description Converter Type :EGC Always Compact type integrated with EGC converter degree type 2V DC to 3V to 23V AC85 to 253V Always /2 NPT female thread G/2 female thread M2 with watertight gland Always Version Refer to the drawing MOUNTING DIRECTION Version 2 OF INDICATOR. Always 2 (Current output Pulse output Status output) Always None Involved * * Add code "/Z" to a series of above mentioned codes with explanation for the other requirements not mentioned above code table. Do not hesitate to consult TOKYO KEISO Co., td. before ordering for such requirements. STANDARD ACCESSORIES Parameter sheet : Instruction manual : OPTION Bolts and nuts : set [Symbol : BN] Material : Stainless steel SUS3 for JISK flange PTFE jacket gaskets for mounting on pipe 2 pieces [Symbol : FG] VAQUA No. N73 for JISK flange Note : Suitable size of bolts and gaskets matching mating flanges will be provided. Please specify the flange rating and size other than JIS K if those fittings are requested. G/2 watertight glands for cable entry : [Symbol : G] e will supply with standard data setting in case you have no request. Please set the data of flow range, pulse rate and flow direction etc. that required operating. ORDERING INSTRUCTIONS Specify the following when ordering :. Model and specification codes Example : Model : EGMC Primary head spec. code : VN7CN3K2 Converter spec. code : VN3A52 2. Full scale flow range. 3. Optional requirements will be added using above mentioned symbols if required.. Fluid name * Specification is subject to change without notice. Head Office : Shiba Toho Building, 7 2 Shibakoen, Minato-ku, Tokyo Tel : (KEY) ; Fax : overseas.sales@tokyokeiso.co.jp ; UR : TG-F55-5E TOKYO KEISO CO., TD. 7
EGM5300C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification
MAGMAX EGM53C Compact Electromagnetic Flowmeter GENERAL MAGMAX EGM53C is a combination of EGS5 primary head with Ceramic measuring tube and high performance converter EGC3. EGM53C with high durability
More informationUL6300 SONICMAX. Ultrasonic Clamp-on Flowmeter OUTLINE FEATURES STANDARD SPECIFICATION. Common specification
SONICMAX UL63 Ultrasonic Clamp-on Flowmeter OUTLINE SONICMAX UL63 is the ultrasonic flowmeter of the time flight system which combined the highly efficient converter (UFC3) with the clamp-on sensor (UFS6).
More informationUL6300 SONICMAX. Ultrasonic Clamp-on Flowmeter OUTLINE FEATURES MEASURING PRINCIPLE
SONICMAX UL63 Ultrasonic Clamp-on Flowmeter OUTLINE SONICMAX UL63 is the ultrasonic flowmeter of the time flight system which combined the highly efficient converter (UFC3) with the clamp-on sensor (UFS6).
More informationMASSMAX 1000 Series Straight twin tube Coriolis Mass Flowmeter
MASSMAX Series Straight twin tube Coriolis Mass Flowmeter OUTLINE MASSMAX series is the coriolis mass flowmeters developed on the theme of the straight tube model which is excellent in cost performance.
More informationVFM4070C SWIRLMAX. Vortex Flowmeter OUTLINE FEATURES OPERATING PRINCIPLE STANDARED SPECIFICATION. General Specification. Sensor Specification
SWIRMAX VFM4070C Vortex Flowmeter OUTINE SWIRMAX is 2-wire, all-in-one type vortex flowmeter with both temperature and pressure sensors integrally mounted into the housing. It allows temperature and pressure
More information1000 Series MASSMAX. Coriolis Mass Flowmeter Straight Twin Tube OUTLINE FEATURES STANDARD SPECIFICATIONS. Fluid Specifications
MSSMX Series Coriolis Mass Flowmeter Straight Twin Tube OUTLINE MSSMX series is the coriolis mass flowmeters developed on the theme of the straight tube model which is excellent in cost performance. The
More informationSTK2000/7400 Series. Flapper-type Flowmeter OUTLINE FEATURES PRINCIPLE STANDARD SPECIFICATIONS. Specifications of the metal measuring tube
STK2000/7400 Series Flapper-type Flowmeter OUTLINE The STK2000 and STK7400 are high-accuracy, high-performance, flapper-type flowmeters. The STK2000 is a local indication type, and the STK7400 is a local
More informationDetector (for water measurement applications)
WaterMAG Smart Electromagnetic Flowmeter Detector (for water measurement applications) Model MGW18 OVERVIEW The WaterMAG electromagnetic flowmeter detector is a high performance, highly reliable flowmeter
More informationSRT1000 Series THERMAL FLOWMETER
High-performance gas flowmeter SRT1000 Series THERMAL FLOWMETER OUTLINE Based on the long experienced know-how on the TOKYO KEISO's thermal flowmeters, SRT1000 series has enhanced its performance such
More informationWaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB
WaterMAG Electromagnetic Flowmeter for Water Applications OVERVIEW The WaterMAG is an electromagnetic flowmeter for water measurement applications based on field proven Azbil Corporation's technologies.
More informationO-1000 Series ORIFLOMETER MOST COST EFFECTIVE FLOW MEASUREMENT GENERAL STANDARD SPECIFICATIONS TYPES AND FUNCITON
MOST COST EFFECTIVE FLOW MEASUREMENT O-1000 Series ORIFLOMETER GENERAL O-1000 series ORIFLO METER is a flow meter consisting of an orifice plate and a metal tube variable area flow meter. Since the flow
More informationISTEC MAGNETIC METERS
ISTEC MAGNETIC METERS MEASURE ANY CONDUCTIVE LIQUIDS OR SLURRIES (EVEN ABRASIVE OR CORROSIVE) WITH THE NEW MICROPROCESSOR-BASED MAGNETIC METER -- A QUALITY PRODUCT - SIMPLE - RELIABLE - AT AN AFFORDABLE
More informationMagnetic-inductive flow meter EPS / UMF2. Technical data sheet
Magnetic-inductive flow meter EPS / UMF2 Technical data sheet high accuracy: 0.3 % of actual maintenance-free no pressure drop numerous lining materials numerous electrode materials low-cost grounding
More information유량계전문제조업체. Electro Magnetic FLOWMETER
유량계전문제조업체 w w w. f c k o r e a i n s. c o m Electro Magnetic FLOWMETER ELECTRO-MAGNETIC FLOW METER Contents Principle of Operation 04 Grounding Method 05~07 Piping Installation 08 CN-400 CNT-2 Flanged
More informationUL350 ULTRASONIC FLOWMETER CLAMP-ON TYPE OUTLINE FEATURES MEASUREMENT PRINCIPLE
CLMP-ON TYPE UL350 ULTRSONIC FLOWMETER OUTLINE Our clamp-on type Ultrasonic Flowmeter UL350 has enabled applications to piping in various kinds by enhancing the permeation property of ultrasonic wave.
More informationMagnetic-inductive flow meter for hazardous areas
Magnetic-inductive flow meter for hazardous areas Technical Datasheet EPX / UMF3 high accuracy: 0.3 % of actual maintenance-free no pressure drop numerous lining materials numerous electrode materials
More informationMagnetic Inductive Flowmeter EP / UMF2 (B)
Magnetic Inductive Flowmeter EP / UMF2 (B) High accuracy 0.3 % of reading No maintenance required no pressure drop different lining materials different electrode materials inexpensive earthing electrode
More informationProduct Data Sheet 2012 Rev 5 FLOWMETRIX SA SAFMAG Electromagnetic Flowmeter Doc Date
FLOWMETRIX SA Doc Date 17.07.2012 PERFORMANCE * 0,5% of rate (Standard) * 0,25% of rate (Optional) * 1000 : 1 operable flow range * Excellent repeatability * Optional Bi-directional measurement * Advanced
More informationR-101-E GLASS TUBE FLOWMETER BEST COST PERFORMANCE GENERAL STANDARD SPECIFICTION. Max. fluid press. MPa Meter size.
BEST COST PERFORMANCE R-1-E GLASS TUBE FLOWMETER GENERAL R-1-E is a glass tube type variable area flowmeter. The flow rate is indicated by the position of float and the graduation engraved on the glass
More informationElectromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids
Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids Flow rate measurement is independent of density, temperature, viscosity and pressure Pulsed coil excitation to
More informationMagneW Neo+ Two-wire Electromagnetic Flowmeter Integral type TIIS Explosion-protected Apparatus
MagneW Neo+ Two-wire Electromagnetic Flowmeter Integral type TIIS Explosion-protected Apparatus OVERVIEW The MagneW Neo+ is a high performance two wired electromagnetic flowmeter based on field proven
More informationHDT1000 series ORIFLO METER. Multi-function Digital Flowmeter OUTLINE STANDARD SPECIFICATION FEATURES MAIN APPLICATIONS INDICATOR SPECIFICATION
ORIFO METER HDT series Multifunction Digital Flowmeter OUTINE HDT is a new series Oriflo meter combining orifice plate with multidigital indicator. HDT detects differential pressure exerted by flow velocity
More informationRosemount 8750WB Magnetic Flowmeter System
Rosemount 8750WB Magnetic Flowmeter System for Utility, Water, and Wastewater Applications Product Data Sheet 00813-0200-4750 Rev AA THE 8750W MAGNETIC FLOWMETER Rosemount reliability customized for Water,
More informationRosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries
Product Data Sheet January 214 813-1-475, Rev FA Rosemount 875WA Magnetic Flowmeter System For Water and Wastewater Industries THE 875WA MAGNETIC FLOWMETER Rosemount reliability in a customized offering
More informationThe Polaris MA1 is the first liquid flow meter offered by Magnetrol, expanding the already diverse level and flow measurement portfolio that has been
The Polaris MA1 is the first liquid flow meter offered by Magnetrol, expanding the already diverse level and flow measurement portfolio that has been established over the last 80 years. The electromagnetic
More informationCDT1000 Series QUICK FLOW. Digital Flowmeter for Air Conditioning Application OUTLINE FEATURES STANDARD SPECIFICATION
QUICK FLOW CDT1 Series Digital Flowmeter for Air Conditioning Application OUTLINE CDT1 is a new series of flowmeter which combines a multidigital indicator with a pitot tube. CDT1 detects the differential
More informationAM9000 Series GENERAL FEATURES METAL TUBE VARIABLE AREA FLOWMETER
METAL TUBE VARIABLE AREA FLOWMETER AM9000 Series GENERAL The AM9000 series metal tube variable area flowmeters have the unified face-to-face dimension mm. Having developed the current well-accepted AM7000
More informationOptions guide. Electromagnetic flowmeters. M9xx
Options guide Electromagnetic flowmeters M9xx Ordering codes Model Description M 910 -V0 0 0 0 DN50 PN16 Example Sensor M Basic Ex Ex certified (remote version only) Transmitter 910E Economic version 910
More informationManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products Rev PK KMS501W & KMS502F- TW. Electromagnetic TRADEWASTE Flowmeters FEATURES:
KMS501W & KMS502F- TW FEATURES: Fitted with Sydney Water Tradewaste plugs (Sampler and ma outputs). For waste water, bore water and irrigation ( upto 10% solids). Unsurpassed accuracy to ±0.5% 0.5 m/s
More informationSTANDARD SPECIFICATIONS
CFW1000 C C C C CFW1000 CFW1 Description Installation 2 Horizontal type 4 Vertical Indicator 1 20 C water calibration 2 7 C and 60 C water, double scale 1 Scale range 1 See right table Scale range 2 Scale
More informationElectromagnetic Flowmeters. Product Overview.
Electromagnetic Flowmeters Product Overview www.lcmeter.com Premier products, premier performance Liquid Controls offers a broad selection of electromagnetic (Mag) flow meters for industrial and water
More informationPMG MAGNETIC FLOWMETER
PMG MAGNETIC FLOWMETER Flow Pressure Level Temperature measurement monitoring control Flow Ranges 0.015-0.5 Through 350-10600 GPM 1/2 to 12 Sizes Accuracy ±0.5% or ±0.25% of Reading Viscosity and Density
More informationAM-2000 series HYBRID FLOWMETER
AM- series HYBRID FLOWMETER OUTLINE AM- series is a new all metal type flowmeter. AM- series integrates formerly separate functional devices to facilitate mounting in restricted spaces. Suitable for liquid,
More informationTechnical Information Proline Promag 10L
TI00100D/06/EN/1816 71326694 Products Solutions Services Technical Information Electromagnetic flowmeter The flowmeter with a weight-optimized sensor and highly cost-effectiveness Application The measuring
More informationUCM -04A/06A RoHS compliance
Converter integrate type ultrasonic flowmeter -4A/6A RoHS compliance ULTRASONIC COMPACT METER LE The -4A/6A is the converter integrate type ultrasonic flowmeter for small flow that offers precise an stable
More informationFLOW METER ULTRASONIC-VOLTEX FLOW METER ASUSV SERIES IMPELLER FLOW METER ASIP80 SERIES IMPELLER FLOW METER ASSPX SERIES
FLOW METER P.193 P.195 P.196 P.197 P.198 P.198 P.198 P.199 P.199 P.200 P.200 P.200 P.200 ULTRASONIC-VOLTEX FLOW METER ASUSV SERIES IMPELLER FLOW METER ASIP80 SERIES IMPELLER FLOW METER ASSPX SERIES INSERTION
More informationFIELD DEVICES - FLOW PSS 1-6F9 A. Product Specifications
FIELD DEVICES - FLOW Product Specifications Logo 9100A Series Magnetic Flowtubes with Ebonite Liners 1 to 78 in (25 to 2000 mm) Nominal Flowtube Sizes The Foxboro brand 9100A Series Magnetic Flowtube together
More informationModels ADMAG AXF and ADMAG CA Sanitary 3A Compliant Integral and Remote Magnetic Flowmeters
General Specifications Models and ADMAG CA Sanitary 3A Compliant Integral and Remote Magnetic Flowmeters ADMAG and ADMAG CA 3A & FDA compliant magnetic flowmeters are dependable and reliable instruments
More informationHENRI Flowmeter for Pulp Slurry
MagneW 3000 PLUS Smart Electromagnetic Flowmeter HENRI Flowmeter for Pulp Slurry Model MGH14 (onverter) / MGH18 (Detector) OVERVIEW The MagneW 3000 PLUS HENRI (High-Energy Noise-Resistant Instrument) flowmeter
More informationLevel Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd
Pointek CLS200 Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable choices liquids, solids,
More informationRCM - Direct Reading Flowmeters
Compact Design Easy to Install Horizontal or Vertical Installation Flow Rates up to 3000 GPM (Liquid) or 20000 SCFM (Gas) Low Pressure Drop Optional Alarms and Output Signals Accuracy: ± 3% of full scale
More informationElectro-Magnetic Flowmeters Sensors MagMaster MFE
Data Sheet (US) Electro-Magnetic Flowmeters Sensors MagMaster MFE Unrivalled flow performance ±0.2% accuracy. Pulsed DC Technology Incorporates Benefits of AC Systems Operable flow range of 1000:1. Two-year
More informationField IT Electro-Magnetic Flowmeters Sensors
Data Sheet Field IT Electro-Magnetic Flowmeters Sensors MagMaster MFE Unrivalled flow performance ±0.2% accuracy. Pulsed DC Technology Incorporates Benefits of AC Systems Operable flow range of 1000:1.
More informationE M F. Description. Principle of Operation. Introduction for EMF Series of Electromagnetic Flowmeters
EMF Series ELECTROMAGNETIC FLOWMETER Description Introduction for EMF Series of Electromagnetic Flowmeters The Electromagnetic Flowmeters(EMF) can be used to accurately measure the flowrate of liquids,
More informationLevel Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.
Pointek CLS200 Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable choices liquids, solids,
More informationElectromagnetic flowmeters
02/97 Electromagnetic flowmeters Primary heads Installation instructions ECOFLUX IFS 1000 F Compact flowmeters IFM 1010 K IFM 1080 K CONTENTS Installation in the pipeline Pages 4-5 and 7-8 Grounding Pages
More informationElectromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids
Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids For use in large diameter pipes as an economical solution for flow measurement Flow rate measurement
More informationABB Instrumentation. MagMaster MFE Series Electromagnetic Sensors. Specifications. MagMaster - bringing unsurpassed flowmetering performance
Specifications MagMaster MFE Series Electromagnetic Sensors nn Unrivalled flow performance ±0.2% accuracy. nn Pulsed DC Technology Incorporates Benefits of AC Systems nn Operable flow range of 1000:1.
More informationTime Delta S Fixed Transit-Time Flow Meter System
Fixed Transit-Time Flow Meter System Key Features Dynamic flow correction Simple configuration Digital outputs Enhanced anti-bubble measurement technology (ABM) Rugged and reliable Maintenance free The
More informationF6700 ELECTROMAGNETIC METER
EETROMAGNETI FOW TRANSMITTER Special Features: F6700 Full Bore type Simple and ost effective onstruction Absolutely Maintenance free Suitable for all conductive liquids and slurries Outstanding Accuracy
More informationFrom. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951)
SPI Mag MODEL 282L SINGLE POINT INSERTION ELECTROMAGNETIC FLOW METER 2 SENSOR SUBMITTAL PACKAGE From McCROMETER, INC. 3255 WEST STETSON AVENUE HEMET, CA 92545 Phone (951) 652-6811 Toll Free (800) 220-2279
More informationInsertion magnetic inductive flowmeter
Insertion magnetic inductive flowmeter Sensor without moving parts Flowmeter with On/Off control Application related calibration by Teach-In function Clean in place (CIP) FDA-compliant materials Type 8041
More informationElectromagnetic Flow Monitor magphant
Technical Information TI 036D/06/en No. 50078457 Electromagnetic Flow Monitor magphant Monitoring and measurement Flow monitoring with selectable limit values (relay output) Flow measurement via 4...20
More informationSmart Electromagnetic Flowmeter Detector for Sanitary use
MagneW3000 PLUS Smart Electromagnetic Flowmeter Detector for Sanitary use Model MGS28U OVERVIEW The MagneW3000 PLUS Smart Electromagnetic Flowmeter for Sanitary use is a high-performance and highly-reliable
More informationModels ADMAG AXF and ADMAG CA Sanitary 3A Compliant Integral and Remote Magnetic Flowmeters
General Specifications Models and ADMAG CA Sanitary 3A Compliant Integral and Remote Magnetic Flowmeters ADMAG and ADMAG CA 3A & FDA compliant magnetic flowmeters are dependable and reliable instruments
More informationElectromagnetic Flow Meter Owner s Manual HARDWARE
Electromagnetic Flow Meter Owner s Manual HARDWARE Compact Magnetic Flowmeter (Flange Connection) Sanitary Magnetic Flowmeter (Tri clamp Connection) Part No. 910000 Rev.C Content 1. GENERAL INFORMATION...2
More informationTechnical Data Sheet IFS 4000 KC (ENVIROMAG) Electromagnetic flowmeters. ... for water and wastewater measurements
Technical Data Sheet KROHNE 05/2004 GR/PRINTO IFS 4000 KC (ENVIROMAG) Electromagnetic flowmeters... for water and wastewater measurements short inlet and outlet runs unaffected by contamination, solids,
More informationElectromagnetic Flow Monitor magphant
Technical Information TI 036D/24/ae Electromagnetic Flow Monitor magphant Flow monitoring in 1 to 80 pipes with conductive liquids Monitoring and measurement Flow monitoring with selectable limit values
More informationLevel Measurement Point level measurement - RF Capacitance switches
Pointek CLS200 - Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level and material detection switch with optional rod/cable
More informationO-180/780 Series ORIFLO METER COST EFECTIVE FLOW MEASUREMENT FOR LIQUIDS AND GASES GENERAL FEATURES MAIN APPLICATIONS
COST EFECTIVE FLOW MEASUREMENT FOR LIQUIDS AND GASES O-18/78 Series ORIFLO METER GENERAL O Series ORIFLO METER is a By-pass Orifice type flowmeter. Small sized variable flowmeter is installed onto measuring
More informationPaddle-wheel flow controller for On/Off control
Paddle-wheel flow controller for On/Off control Type 8032 can be combined with... Indication, monitoring, transmitting and On/Off control in one device Programmable outputs (transistor or relay) Automatic-calibration:
More informationElectromagnetic flowmeter EMKO E
Electromagnetic flowmeter EMKO E - Quality design - High corrosion resistance - Reliable measurement principle Doc. no.: 70, en_cat_emkoe, 8/2015 Description Electromagnetic Flowmeter EMKO E consists of
More informationSHENITECH, LLC
SHENITECH, LLC Features and Benefits 100-H Tower Office Park, Woburn, MA 01801 Mag888 Electromagnetic Flow Converter The Mag888 flow converter is used together with the Mag888 flow sensor to form a complete
More informationVortex Flowmeters VFM 3100 F-T VFM 3100 W-T
KROHNE 10/2001 7.02313.23.00 GR/OP Vortex Flowmeters F-T W-T Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters Level measuring
More informationSITRANS F M flow sensors 711/A and 711/911E
s flow sensors 711/A and 711/911E flow sensors 711/A and 711/911E Introduction Application Mode of operation, operation Mode of operation All electromagnetic flow measurements are based on Faraday s Law
More informationDigital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series
Digital Vortex meter digitalyewflo Digital Vortex meter Series Unrivaled Performance, Functionality and Ease of Use Series Standard Type / Multi-variable Type High Temperature / Cryogenic Type Reduced
More informationElectromagnetic amplifier Primo Advanced for all detectors
Electromagnetic amplifier Primo dvanced for all detectors Features ccuracy ±0,25% Flow range 0,03 12 m/s 6 2000 LC display Power supply 85 2 VC / 24 VC escription imensions The amplifier type Primo dvanced
More informationElectric Top-Guided Single-Seated Control Valves
No. SS2-AGV200-0300 CV3000 Alphaplus series Electric Top-Guided Single-Seated Control Valves Model AGVB / AGVM OVERVIEW The CV3000 Alphaplus range of top-guided single-seat control valves features a compact
More informationElectromagnetic flowmeters for water and seewage
09/97 Electromagnetic flowmeters for water and seewage Primary head Compact flowmeters Installation instructions AQUAFLUX F 0 K 020 K 080 K CONTENTS Storage and transport Pagesn 3-4 Installation in the
More informationO-100 Series GLASS TUBE TYPE ORIFLOMETER BEST COST EFFECTIVE FLOW MEASUREMENT EVEN FOR LARGE SIZE LINES GENERAL STANDARD SPECIFICATION MODEL CODE
BEST COST EFFECTIVE FLOW MESUREMENT EVEN FOR LRGE SIZE LINES O-0 Series GLSS TUBE TYPE ORIFLOMETER GENERL O-0 series ORIFLO METER is a flow meter consisting of a orifice plate and a GLSS TUBE type variable
More informationINSERTION flow sensor for continuous flow measurement
INSERTION flow sensor for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN)
More informationCDT1000 series QUICK FLOW. Digital Flowmeter for Air Conditioning Application OUTLINE FEATURES STANDARD SPECIFICATION
QUICK FLOW CDT1 series Digital Flowmeter for ir Conditioning pplication OUTLINE CDT1 is a new series of flowmeter which combines a multidigital indicator with a pitot tube. CDT1 detects the differential
More informationMEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Electromagnetic BTU Meter
MEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Features The T-MAG BTU meter is the latest addition to the SpireMag series for accurate thermal energy measurement. It utilizes a high accuracy electromagnetic
More informationmass flowmeter for compressed air
mass flowmeter for compressed air VARIOMASS ECO pressure and temperature compensated easy and cost effective installation of the sensor no pressure loss caused by the sensor no moving parts, i.e. maintenance
More informationSmart Pressure Transmitter
DOC. O.: C3700-L-E16A Smart Pressure Transmitter with Diaphragm Seal MODEL APT3700-L 298-29, GODA-RO, GUPO-SI, GYEOGGI-DO, KOREA 15809 Tel : +82-31-3-6100 Fax : +82-31-29-7200 E-mail: autrol@duon.co.kr,
More informationHG5 Series. Metal Tube Rotameter CATALOG MAIN FEATURES TECHNICAL PARAMETERS
H5 Series Metal Tube Rotameter H5 series metal tube rotameter (also called variable area flow meter) is a kind of measuring meter which the flow rate is changing along with the area and is widely used
More informationUFM 800 W, C and UFM 800 W Hot Tapping. Ultrasonic flowmeters. for water and wastewater
KROHNE 12/2006 7.02343.22.00 MAR UFM 800 W, C and UFM 800 W Hot Tapping Ultrasonic flowmeter for water and wastewater...with weld-in sensors for metal pipelines...with built-on or built-in sensors for
More informationFLS F6.60 MAGMETER FLOW SENSOR INSERTION FLOW SENSORS APPLICATIONS MAIN FEATURES
FLS F6.60 MAGMETER FLOW SENSOR The new F6.60 and F6.63 are flow meters without moving mechanical parts which can be applied for the measurement of dirty liquids so long as they are conductive and homogeneous.
More informationEPS / UMF2. Magnetic Inductive Flowmeter for Conductive Liquids
Magnetic Inductive Flowmeter for Conductive Liquids measuring monitoring analyzing EPS / UMF2 High Accuracy: 0.3 % of Actual Flow Maintenance-free No Pressure Drop Wide Variety of Lining and Electrode
More informationPressure transmitter for general purpose Type MBS 1700 and MBS 1750
MAKING MODERN LIVING POSSIBLE Data sheet Pressure transmitter for general purpose Type MBS 1700 and MBS 1750 The compact pressure transmitters MBS 1700 and MBS 1750 are designed for use as a general purpose
More informationΑΥΤΟΜΑΤΗ ΣΤΡΑΤΣΩΝΑ ΕΛΕΓΚΤΕΣ
ΑΥΤΟΜΑΤΗ ΣΤΡΑΤΣΩΝΑ ΕΛΕΓΚΤΕΣ TI-P403-52 / 4033xxB 1/5 AB Issue 3 and Blowdown Controllers Compact unit for TDS control on large or small boilers. Wall or panel mounted versions. 4 digit LED display (ppm
More informationF-2700 SERIES INSERTION VORTEX FLOW METER
F-2700 SERIES INSERTION VORTEX FLOW METER APPLICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260
More informationElectromagnetic Flowmeter for Partially-filled Pipes
Electromagnetic Flowmeter for Partially-filled Pipes LF502/LF232*F 6 to 24 (150 to 600 mm ) Introduction The LF502 electromagnetic flowmeter uses Faraday s Law of electromagnetic induction in the same
More informationThe Multivariable Air Flow Meter
The Multivariable Air Flow Meter Model MVC10A/MVC10F OVERVIEW The Multivariable Mass Flow Meter model MVC10A/ MVC10F, a compact has all function necessary to measure nitrogen (N 2 ) gas, carbon dioxcide
More informationElectromagnetic flowmeter. Descriptions. Specifications
Descriptions The EFM Series is the most economical flanged electromagnetic flowmeter on the market. It is used in 3 to 12 pipe in HVAC, municipal or industrial water, wastewater, pump stations and packaged
More informationAppendix. Clearance. Skewed profiles. Application Schematics
Appendix Application Schematics The purpose of the application schematics is to show different applications and the best sensor location for a particular application. Clearance Because the sensor will
More informationElectromagnetic Flow Measuring System PROline promag 10 W
Technical Information TI 093D/06/en 50104872 Electromagnetic Flow Measuring System PROline promag 10 W Flow measurement in water or wastewater applications Application Electromagnetic flowmeter for measuring
More informationF-1500 SERIES INSERTION TURBINE FLOW METER
F-1500 SERIES INSERTION TURBINE FLOW METER APPLICATIONS Saturated steam Hot water to 450 F (232 C) standard 850 F (454 C) optional Applications with optional pressure sensor Superheated steam to 450 F
More informationTEK-F LUX 1400A. Electromagnetic Flowmeter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys FLOW
Technology Solutions TEK-F LUX 1400A Electromagnetic Flowmeter FLOW www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Electromagnetic flowmeters are also
More informationORIFLO CONTENTS COST EFECTIVE FLOW MEASUREMENT FOR LIQUIDS AND GASES INTEGRATED ORIFICE FLOWMETERS GENERAL FEATURES MAIN APPLICATIONS
COST EFECTIVE FLOW MEASUREMENT FOR LIQUIDS AND GASES ORIFLO INTEGRATED ORIFICE FLOWMETERS GENERAL O series ORIFLO METER is a By-pass Orifice type flowmeter. Small sized variable flowmeter is installed
More informationPaddle-wheel flow controller for On/Off control
Paddle-wheel flow controller for On/Off control Type 803 can be combined with... Indication, monitoring, transmitting and On/Off control in one device Programmable s (transistor or relay) Automatic-calibration:
More informationPressure transmitter for industrial applications Type MBS 4500
MAKING MODERN LIVING POSSIBLE Data sheet Pressure transmitter for industrial applications Type MBS 4500 The high accuracy pressure transmitter MBS 4500 is designed for use in almost all industrial applications,
More informationVersaFlow Vortex 100 Vortex Flow Meter Specifications
VersaFlow Vortex 100 Vortex Flow Meter Specifications 34-VF-03-05 May 2011 The All-In-One Solution The VERSAFLOW is the only vortex flowmeter with integrated and temperature compensation in 2- wire technology.
More informationF-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)
F-1500 SERIES INSERTION TURBINE FLOW METER Insertion turbine flow meters are ideal for use in larger steam lines where downsizing the line size to improve flow measurement is not desirable. In these applications,
More informationPressure transmitter for general industrial purposes MBS 3000 and MBS 3050
Data sheet Pressure transmitter for general industrial purposes MBS 3000 and MBS 3050 The compact pressure transmitter, type MBS 3000, is designed for use in almost all industrial applications, and offers
More informationThe Multivariable Air Flow Meter
No. SS2-MVC200-0100 OVERVIEW The Multivariable Mass Flow Meter AIRcube, a compact has all function necessary to measure nitrogen (N 2 ) gas, carbon dioxcide (CO 2 ) gas and air. The model MVC10A/MVC10F
More informationAbridged Specifications: 10D1477 Electrodeless Sensor with 50XM1000 Transmitter
Abridged Specifications: 10D1477 Electrodeless Sensor with 50XM1000 Transmitter The 10D1477 electrodeless ceramic lined wafer sensors and 50XM1000 transmitters are pulsed DC magnetic flowmeters. These
More informationFP-4000 Series FLOAT LEVEL SWITCH OUTLINE MAIN APPLICATIONS STANDARD SPECIFICATION
FOR MULTIPOINT LEVEL ALARM ETECTION BY ONE UNIT FP- Series FLOAT LEVEL SWITC OUTLINE The FP- series is a float level switch, which is installe through the tank nozzle on tanks an/or pits. Level alarm etection
More informationPaddle-wheel flow controller with optical principle for On/Off control
Paddle-wheel flow controller with optical principle for On/Off control Type 8039 can be combined with... Indication, monitoring, transmitting and On/Off control in one device. Programmable s (transistor
More informationUltrasonic Flowmeter. M-1500 Plus Non-invasive Inline DSP Ultrasonic Flowmeter. Operating Principle. Features
M1500 Plus Noninvasive Inline DSP Ultrasonic Flowmeter Accuracy ± 2% of Reading All wetted parts made of PFA Contamination free from ions or particles Minute flow measurements down to 4 ml/min* Easy configuration
More information