AM9000 Series GENERAL FEATURES METAL TUBE VARIABLE AREA FLOWMETER
|
|
- Caren Golden
- 5 years ago
- Views:
Transcription
1 METAL TUBE VARIABLE AREA FLOWMETER AM9000 Series GENERAL The AM9000 series metal tube variable area flowmeters have the unified face-to-face dimension mm. Having developed the current well-accepted AM7000 series, the AM900 has a compact and unified construction which makes piping design simpler and saves installation space, leading to a low engineering cost. In addition to highly reliable mechanical local indicator, a variety of standard-equipped functions such as electric transmission, local flow integration and integrated flow transmission by pulse, alarm, and digital communication of these data can meet your various requirements. The AM9000 covers liquid, gas and steam measurement in various fields. FEATURES FULL LINE-UP TO MEET ALL POSSIBLE REQUIREMENTS!! All the necessary functions required for variable area flowmeter, i.e. local indication, electric transmitters, local flow integration, PROFIBUS PA & HART communication, integrator with scaled pulse output and alarm are now available from one line. COMPACT DESIGN Smaller and lighter To suit modern needs. Unified face-to-face dimension mm makes piping design easier. WIDE PRESSURE RANGE 0 lbs and 00 lbs rating are available as standard and higher pressure versions are also available as option. HART COMMUNICATION PROTOCOL AND PROFIBUS PA CORRESPONDING TO EXPLOSION PROOF CONSTRUCTION Certification: TIIS, KOSHA, NEPSI, ATEX & IECEx DUST TIGHT AND WATER IMMERSION PROOF IP7
2 MODEL CODE Basic model Material/Connection code Function Function Basic model and Function code may be indicated in the quotation. code code etc. AM9 - - / / Specifications Flow direction Bottom Top Function of indicator L E H P T R N M Local indication Electric transmitter Electric transmitter with HART communication PROFIBUS PA Communication Local integration Reed switch Proximity switch Microswitch W Dust tight, water immersion proof, non-explosionproof Explosionproof E Flameproof version S Intrinsic safety version Not applicable to local integrator with scaled pulse output Wetted material - 0 Material of main body :0SS/SCS Material of float : LSS - 0 LSS/SCS LSS J JIS 0K J JIS 0K A ANSI CLASS 0 Rating A ANSI CLASS 00 P JPI CLASS 0 P JPI CLASS 00 Z Z Others Connection R R.F. - mm (/") - 0 mm (/") - mm (") - 0 mm (-/") - 0 mm (") Connection size - mm (-/") mm (") - A 00 mm (") - B mm (") - C 0 mm (") - D 00 mm (8") - Z Others Additional function Additional function Option Special spec. Additional function Output function Explosionproof type Cleaning Painting Test Accessory Double scale Others / D U / E Electric transmitter / E Electric transmitter (intrinsically safe) / H Electric transmitter with HART communication / H Electric transmitter with HART communication (intrinsically safe) / P PROFIBUS PA communication / P PROFIBUS PA Communication (intrinsically safe) / T Local iintegrator+electric transmittert+integrator with scaled pulse (or alarm) / T H Local indication+analog current output with HARTcommunication+Integrated pulse (or alarm) / R Reed switch shows conditions of switch action. / N Proximity switch A : High alarm CLOSE(ON), B : High alarm OPEN(OFF), C : Low alarm CLOSE(ON), D : Low alarm OPEN(OFF) / M Microswitch Ex. Reed switch/-point alarm (High alarm CLOSE, OPEN ): /RAB / J E TIIS Flameproof version / K E KOSHA Flameproof version / C E NEPSI Flameproof version Not applicable to reed switch and proximity switch. See page / E E ATEX Flameproof version for details. / E E IECEx Flameproof version (Specify separately.) / J I TIIS Intrinsical safety version / K I KOSHA Intrinsical safety version Not applicable to local integrator with scaled pulse output. See / C I NEPSI Intrinsical safety version page for details. / E I ATEX Intrinsical safety version / M M0.(F) Not applicable to local integrator with scaled pulse output / G G/(F) Not applicable to local integrator with scaled pulse output / G G/(F) Applicable to local integrator with scaled pulse output / N NPT/(F) Not applicable to local integrator with scaled pulse output / N NPT/(F) Applicable to local integrator with scaled pulse output / O L Oil-free treatment / W L Water-free treatment / A P Pickling treatment / P S Special painting color / L T Airtight test / P C Waterproof connector Not applicable to flameproof version / F G Flameproof cable gland / A C Other accessories / W S Double scale, output for main scale Not applicable to alarm output / W E Double scale, output for main and sub scalels Not applicable to alarm output and local integration / Z Z Gas damper Contact us for details. TOKYO KEISO CO., LTD. TG-F0-9E
3 STANDARD SPECIFICATION FUNCTIONS AM9 AM9 /E AM9 /H AM9 /P AM9 /T AM9 /R, /N, /M Local indication Local indication Electric transmitter Local indication Electric transmitter HART communication Local indication PROFIBUS PA Local indication Electric transmitter Local integration Pulse output Alarm output Local indication Alarm output METER SIZE to 0 (Consult us for sizes of 00 or larger.) See "AVAILABLITY OF CONNECTION SIZE" for available connection sizes corresponding to meter sizes. MATERIAL 0 SS, L SS PRESSURE RATING 0lbs (0K) class, 00lbs (0K) class Consult TOKYO KEISO Co., Ltd. for higher pressure services. See "AVAILABLITY OF CONNECTION" below for the standard rating. FLUID PRESSURE. MPa at room temperature. MPa at 0 C The maximum fluid pressure differs depending on fluid temperatures. Low pressure 0lbs (0K) class Middle pressure 00lbs (0K) class Max. Fluid Temp. ( C) to 0 to 0 to 00 to 0 to 0 to 00 Max. Fluid Press. (MPa) See FLUID TEMPERATURE on page for the operating temperature range. CONNECTION Standard flange connection Low pressure Middle pressure JIS 0K RF JIS 0K RF ANSI, JPI, DIN Other type are available TG-F0-9E TOKYO KEISO CO., LTD.
4 AVAILABLITY OF CONNECTION SIZE FLUID TEMPERATURE Metallic material Notes for the following table * A JIS 0K flange is used for a JIS 0K flange with a connection size of to 0 mm. Both flanges have the same dimensions except that JIS 0K flanges are mm thicker than JIS 0K flanges. * Use stud bolts to mount the flowmeter on the pipe flanges. * These connection sizes are available. However, the face-to-face dimension becomes 0 mm longer than standard for the meter size 00 mm or smaller, and 0 mm longer than standard for the meter size mm or larger. Consult us for details. AM9 AM9 /DU Operating temperature range of fluid 0 to 00 C* 0 to 0 C * The range of 0 to C is possible as option. INDICATION ACCURACY ±. F.S. (On request ±.0 F.S., Consult factory) STANDARD SCALE LENGTH 70 mm RANGEABILITY 0: INDICATOR CONSTRUCTION Dust tight and water immersion proof IP7 PAINTING COLOR PAINTING COLOR Indicator body Indicator cover. Transmitter Jade green Light gray Munsell 7.BG/. Munsell N7. AM9 (LOCAL INDICATION) AMBIENT TEMPERATURE -0 to 80 C DIMENSION OF INDICATOR Approx. mass:.kg 77 0 TOKYO KEISO CO., LTD. TG-F0-9E
5 AM9 /E (LOCAL INDICATOR WITH ELECTRIC TRANSMITTER) AM9 /E indicates flow rate by pointer and scale plate, and outputs electric ( to 0mA DC) signal which is proportional to flow rate. In addition to the dust tight and water immersion proof type, the intrinsically safe and flame proof versions. SPECIFICATION OF TRANSMITTER Power supply voltage : 0 to 0 V DC Voltage between transmitter terminals (For Intrinsically safe version : 0 to 8 V DC/For TIIS Flameproof version: to 0 VDC) Current output : to 0 ma DC Effective output range :.0 to. ma At abnormal condition, however,.8 ma or.7 ma as an option can be output. Allowable load resistance : Less than 80Ω (80Ω or less / V DC) Determine the allowable load resistance for each supply voltage using following formula. Allowable load resistance (Power supply voltage [V] 0 ) / 0.0 [Ω] The allowable load resistance includes the one of circuit wiring. Output accuracy : ±.0%F.S. (Against flow calibration) Low cut off : 0 to 0 %F.S. (default 7 %F.S.) Damping : 0 to 0 s (default s) : Weather proof M0., G/, NPT/, Weather proof connector : Intrinsically safe & Flame proof M0., -G/, NPT/, Packing type cable gland Note : The packing type cable gland model SXC -BY made by Shimada Electric Co. shall be used for the TIIS flame proof construction. Å@Å@Å@Å@Å@Å@Å@Å@Å@Å@ The cable entry for the indicator is G / only. Construction : Dust tight and water immersion proof IP7 : Intrinsically safe Ex ia IIC T to T AM9 /E/ I The temperature class of TIIS certified products is T (Certification is under examination). : Flame proof Ex d IIC T to T AM9 /E/ E The temperature class is T for TIIS Certified products Ambient temp. : Dust tight and water immersion proof 0 to 70 C : Intrinsically safe 0 to 0 C : Flame proof 0 to C (For TIIS Certified products) 0 to 0 C (For other certified products) Insulation resistance : 0 MΩ or more / 00V DC (between batch of power supply terminal and indicator case) Withstand voltage : 00 V AC/ min (between batch of power supply terminal and indicator case) DIMENSION OF INDICATOR / TRANSMITTER 77 TERMINAL AND WIRING Power supply A + Load resistance E TG-F0-9E TOKYO KEISO CO., LTD.
6 AM9 /H (LOCAL INDICATOR WITH ELECTRIC TRANSMITTER & HART COMMUNICATION) AM9 /H indicates flow rate by pointer and scale plate, and outputs electric ( to 0mA DC) signal equipped with HART Communication complying with Multi-drop. In addition to the dust tight and water immersion proof type, the intrinsically safe and flame proof versions. SPECIFICATION OF TRANSMITTER Power supply voltage : 0 to 0 V DC Voltage between transmitter terminals (For Intrinsically safe version: 0 to 8 V DC/For TIIS Flameproof version: to 0 VDC) Current output : to 0 ma DC Effective output range :.0 to.ma At abnormal condition, however,.8ma or.7ma as an option can be output. Allowable load resistance : 0 to 80Ω (Not less than 0Ω load resistance is needed for with HART communication. ) Determine the allowable load resistance for each supply voltage using following formula. Allowable load resistance (Power supply voltage [V] 0) / 0.0 [Ω] The allowable load resistance includes the one of circuit wiring. Output accuracy : ±.0%F.S. (Against flow calibration) Low cut off : 0 to 0%F.S. (default 7% F.S.) Damping : 0 to 0s (default s) : Weather proof M0., G/, NPT/, Weather proof connector : Intrinsically safe & Flame proof M0., G/, NPT/, Packing type cable gland Note : The packing type cable gland model SXC -BY made by Shimada Electric Co. shall be used for the TIIS flame proof construction. The cable entry for the indicator is G / only. Construction : Dust tight and water immersion proof IP7 : Intrinsically safe Ex ia IIC T to T AM9 /H/ I The temperature class of TIIS certified products is T (Certification is under examination.) : Flame proof Ex d II T to T AM9 /H/ E The temperature class is T for TIIS Certified products Ambient temp. : Dust tight and water immersion proof 0 to 70 C : Intrinsically safe 0 to 0 C : Flame proof 0 to C (For TIIS Certified products) 0 to 0 C (For other certified products) Insulation resistance : 0 MΩ or more/00v DC (between batch of power supply terminal and indicator case) Withstand voltage : 00V AC/min (between batch of power supply terminal and indicator case) DIMENSION OF INDICATOR / TRANSMITTER 77 TERMINAL AND WIRING Power supply Load resistance A + E TOKYO KEISO CO., LTD. TG-F0-9E
7 AM9 /P (LOCAL INDICATOR WITH -WIRE PROFIBUS PA COMMUNICATION) AM9 /P indicates flow rate by pointer and scale plate, and PROFIBUS PA Communication for process automation. In addition to the dust tight and water immersion proof type, the intrinsically safe and flame proof versions. SPECIFICATION OF TRANSMITTER Power supply voltage : Bus power supply 0 to V DC However, the power supply for the intrinsically safe circuit with the safety barrier, and with FISCO system is 0 to V DC, and 0 to 7. V DC respectively. BUS Communication Base current : less than ma In/output signal : Manchester-coded Bus Powered (IEC 8-) Communication protocol : PROFIBUS DP-V Device profile : PROFIBUS PA Profile V.0 Function block : Analog Input for volume (or mass) flow rate Totalizer for volume (or mass) flow counter Output accuracy : ±.0 % F.S. (Against flow calibration) : Weather proof M0., G/, NPT/, Weather proof connector : Intrinsically safe & Flame proof M0., G/, NPT/, Packing type cable gland Note : The packing type cable gland model SXC -BY made by Shimada Electric Co. shall be used for the TIIS flame proof construction. The cable entry for the indicator is G / only. Construction : Dust tight and water immersion proof IP7 : Intrinsically safe Ex ia IIC T to T AM9 /P/ I : Flame proof Ex d IIC T to T AM9 /P/ E The temperature class is T for TIIS certified products Ambient temp. : Dust tight and water immersion proof 0 to 70 C : Intrinsically safe 0 to 0 C : Flame proof 0 to C (For TIIS certified products) 0 to 0 C (For other certified products) Insulation resistance : 0 MΩ or more/00 V DC (between batch of power supply terminal and indicator case) Withstand voltage : 00 V AC/ min (between batch of power supply terminal and indicator case) DIMENSION OF INDICATOR / TRANSMITTER 77 TERMINAL AND WIRING DP/PA Coupler or DP/PA Link + E TG-F0-9E TOKYO KEISO CO., LTD. 7
8 AM9 /T (LOCAL INDICATOR WITH LOCAL INTEGRATION, INTEGRATION PULSE, ELECTRIC TRANSMISSION AND HART COMMUNICATION) With local flow rate indication, AM9 /T has the functions of local flow integration, integration pulse output, to 0mA electric output and Hart communication. This series serves the custody of fl ow. The additional magnetic sensing switches to conventional push buttons are available for customers' convenience. In addition to the dust tight and water immersion proof type, and the flame proof version. SPECIFICATION OF TRANSMITTER Integration : digit red LCD (With 8 digit scaling and reset function) Count rate : Less than 0 Hz (Less than 000 c/h) Pulse or Alarm output : NPN Open collector point select output (Pulse width : 0 ms, 0 ms, 00 ms, 00 ms, 00 ms) : point alarm + pulse output, or points alarm output (Alarms are selectable from the flow rate or the integrated flow alarm.) : Max. voltage 0 V DC, max. current 0 ma (The power supply circuit and the output circuit are insulated.) Reverse-connected protection, Residual voltage when turning it on more less. V (0 ma) Integration accuracy : ±.0 %F.S. (Against flow calibration) Power supply : to 0 V DC Voltage between transmitter terminals Current consumption : Less than 0 ma Current output : to 0mA DC Effective output range :.0 to. ma At abnormal condition, however,.8 ma or.7 ma as an option can be output. Allowable load resistance : Less than 80Ω (In case of HART communication version : 0 to 80Ω) Determine the allowable load resistance for each supply voltage using following formula. Allowable load resistance (Power supply voltage [V] 0) / 0.0 [Ω] The allowable load resistance includes the one of circuit wiring. Output accuracy : ±.0 %F.S.(Against flow calibration) Low cut off : 0 to 0 %F.S. (default 7%F.S.) Damping : 0 to 0 s (default s) : G/, NPT/, Packing type cable gland Note : The packing type cable gland model SXC -BY made by Shimada Electric Co. shall be used for the TIIS flame proof construction. The cable entry for the indicator is G / only. Construction : Dust tight and water immersion proof IP7 : Flame proof Ex d IIC T to T AM9 /T / E The temperature class is T for TIIS certified products Ambient temp. : Dust tight and water immersion proof 0 to 70 C : Flame proof 0 to C (For TIIS Certified products) 0 to 0 C (For other Certified products) Insulation resistance : 0 MΩ or more/00 V DC (between batch of power supply terminal and indicator case) Withstand voltage : 00 V AC/min (between batch of power supply terminal and indicator case) DIMENSION OF INDICATOR 77 TERMINAL AND WIRING Terminal No. Terminal wiring DO+ DO DO+ DO R+ 7 R 8 PS+ 9 PS 0 FG (Attention) DO: Contact output terminals, R: 0 ma analog output terminals, PS: Power supply, FG: Grounding 8 TOKYO KEISO CO., LTD. TG-F0-9E
9 AM9 /R (LOCAL INDICATOR WITH REED SWITCH TYPE ALARM) AM9 /R indicates flow rate by pointer and outputs SPST contact at set point for flow alarm. In addition to the dust tight and water immersion proof type, and the intrinsically safe version. SPECIFICATION OF TRANSMITTER Alarm point Switch : points ( point high alarm, point low alarm or points high and low alarm) : Reed switch (a or b contact) Rating : Self-holding reed switch (SPST) 0 VA AC, 0 W DC as resistance load Max. V AC/0. A, Max. 00 V DC/0.A Setting accuracy : ±. % F.S. (Against flow calibration) Note: While switch is on, and if any other flow rate than the alarm setting value is indicated, it result in causing wrong Reset span Enclosure : Less than % F.S. (Against flow calibration) : G/ or NPT/ or others : Dust tight and water immersion proof IP7 : Intrinsically safe Ex ia IIC T...T (TIIS certified products are subject to the safety barrier. See Page for details.) Ambient temp. Insulation resistance Withstand voltage : 0 to 0 C (The intrinsically safe type is subject to the safety barrier.) : 00 MΩ or more/00 V DC (between batch of power supply terminal and indicator case) : 00 V AC/min (between batch of power supply terminal and indicator case) DIMENSION OF INDICATOR / TRANSMITTER (7) (7) Approx. mass:.8 kg TERMINAL AND WIRING High alarm Low alarm Terminal No. High alarm Terminal No. Low alarm Wiring of high alarm Wiring of low alarm Note : Terminal No. and are not used for point high alarm. Likewise, terminal No. and are not used for point low alarm. TG-F0-9E TOKYO KEISO CO., LTD. 9
10 AM9 /N (LOCAL INDICATOR WITH PROXIMITY SWITCH TYPE ALARM) With local flow rate indication, AM9 /N has a proximity switch which outputs alarm signals complying with NAMUR standard. In addition to the dust tight and water immersion proof type, the intrinsically safe version is under examination for certification. SPECIFICATION OF TRANSMITTER Alarm point Switch : points ( point high alarm, point low alarm or points high and low alarm) : Proximity switch Power supply voltage : 8 V DC Operating current Setting accuracy Reset span Enclosure : Proximity switch complying with NAMUR, ON :ma or less, OFF : ma or more : ±. % F.S. (Against flow calibration) : Less than. % F.S. (Against flow calibration) : G/ or NPT/ or others : Dust tight and water immersion proof IP7 : Intrinsically safe Ex ia IIC T...T (The temperature class of TIIS certified products is T. See Page for details.) Ambient temp. : Dust tight and water immersion proof to 80 C : Intrinsically safe 0 to 0 C subject to the safety barrier. Insulation resistance : 00 MΩ or more/00 V DC (between batch of power supply terminal and indicator case) Withstand voltage : 00 V DC/min (between batch of power supply terminal and indicator case) DIMENSION OF INDICATOR / TRANSMITTER (7) (7) Approx. mass:.8 kg TERMINAL AND WIRING Terminal No. High alarm Terminal No. Low alarm + + Note : Terminal No. and are not used for point high alarm. Likewise, terminal No. and are not used for point low alarm. 0 TOKYO KEISO CO., LTD. TG-F0-9E
11 AM9 /M (LOCAL INDICATOR WITH MICRO SWITCH TYPE ALARM) With local flow rate indication, AM9 /M has a micro switch which outputs SPDT alarm signals. In addition to the dust tight and water immersion proof type, the intrinsically safe version is available. SPECIFICATION OF TRANSMITTER Alarm point Switch Rating Setting accuracy : points ( point high alarm, point low alarm or points high and low alarm) : Micro switch (c contact) : V AC/A as resistance load : ±.% F.S. (Against flow calibration) Note: While switch is on, and if any other flow rate than the alarm setting value is indicated, it may result in causing wrong accuracy. Reset span Enclosure : Less than 0% F.S., less than 0% F.S. when alarm contacts work simultaneously. (Against flow calibration) : G/ or NPT/ or others : Dust tight and water immersion proof IP7 : Intrinsically safe Ex ia IIC T...T (TIIS certified products are subject to the safety barrier. See Page for details.) Ambient temp. : Dust tight and water immersion proof to 80 C : Intrinsically safe 0 to 0 C subject to the safety barrier. Insulation resistance Withstand voltage : 00 MΩ or more/00v DC (between batch of power supply terminal and indicator case) : 00V AC/min (between batch of power supply terminal and indicator case) DIMENSION OF INDICATOR / TRANSMITTER (7) (7) Approx. mass:.8 kg TERMINAL AND WIRING High alarm Low alarm COM COM NC. NO. NC. NO. Terminal No. High alarm Terminal No. Low alarm COM. COM. NC. NC. NO. NO. Note : Terminal No.,, are not used for point high alarm. Likewise, terminal No.,, are not used for point low alarm. TG-F0-9E TOKYO KEISO CO., LTD.
12 AM9 /M / E (FLAME PROOF) AM9 /M / E outputs an alarm signal by SPDT contacts by adding a micro switch to the local flow rate indicator. SPECIFICATION OF TRANSMITTER Alarm point Switch Rating Setting accuracy : points ( point high alarm, point low alarm or points high and low alarm) : Micro switch (c contact) : V AC/A or 0V DC/A : ±.% F.S. (Against flow calibration) Note: While switch is on, and if any other flow rate than the alarm setting value is indicated, it may result in causing wrong accuracy. Reset span Enclosure : Less than % F.S. (Against flow calibration), less than 0% F.S. when alarm contacts work simultaneously. : G/ or NPT/ or others : Dust tight and water immersion proof IP7 : Flameproof Exd IIC T to T The temperature class of the model certified by TIIS is T. See page for details. Ambient temp. : Dust tight and water immersion proof to 80 C : Flameproof 0 to C (For TIIS certified products) 0 to 0 C (For other certified products) Insulation resistance Withstand voltage : 00 MΩ or more/00v DC (between batch of power supply terminal and indicator case) : 00V AC/min (between batch of power supply terminal and indicator case) DIMENSION OF INDICATOR / TRANSMITTER TERMINAL AND WIRING High alarm Low alarm COM COM NC. NO. NC. NO. Terminal No. High alarm Terminal No. Low alarm COM. COM. NC. NC. NO. NO. Note : Terminal No.,, are not used for point high alarm. Likewise, terminal No.,, are not used for point low alarm. TOKYO KEISO CO., LTD. TG-F0-9E
13 AM9 / / E (FLAMEPROOF VERSION) II II II IIII II AM9 / / I (INTRINSICALLY SAFE VERSION) II II II II IIII INTRINSICALLY SAFE SPECIFICATION OF CURRENT TRANSMISSION AND PROFIBUS PA COMMUNICATION INTRINSICALLY SAFE SPECIFICATION OF ALARM OUTPUT II TG-F0-9E TOKYO KEISO CO., LTD.
14 ADDITIONAL FUNCTION GAS DAMPER (Model AM9 /DU) All flowmeters with their meter sizes ranging from to 00 mm for gas measurement are equipped with gas dampers as standard. Mechanical damper is integrated at the part of float guide which consists of piston and cylinder. As it is not required to install liquid damper at the bottom of flowmeters, it contributes to increase the flexibility of piping design. Also it is not required to fill damper liquid that saves maintenance labour works. Gas damper is applicable for gas and steam measurement applications and not suitable for liquids. Also chlorine gas (easy to form chemical compound) and gas containing rust, trash and oil may hinder the function of piston part. Stopring Cylinder Piston Float rod Tapered tube Float DIMENSIONS, MATERIAL, PRESSURE DROP, FLOW RATE TABLE The mass in the following tables shows the one of the type with a local indicator only. See the each item "DIMENSION INDICATOR/ TRANS- MITTER" with the individual transmitter for its dimensions and mass. Model AM9 (Flow direction Bottom to Top) Measuring fluids : Liquids Table Meter size No Table Flow rate of water Pressure loss (m /h) (kpa) 0.0 to * Description Material class Tapered tube SCS/L SS Float assembly L SS Flange 0 SS Float guide SCS/L SS Stopring SS Indicator ADC L (mm) K, Class 0 * (B) (mm) Mass (Approx.) * 0. to. m/h for the micro switch type (AM9 /M_). * The float rod comes out 0 mm during operation in the case of flowmeters with a meter size from 00 mm to 0 mm. Material class SCS/L SS L SS L SS SUS/L SS SS ADC Model AM9 /DU (Flow direction Bottom to Top with gas damper) Measuring fluids : Gases and Steam Table Meter size Flow rate of air [m /h(nor)] 0 * Pressure loss Dimension(mm) Mass (Approx.) (kpa) L B (kg)/jis0k * to 0 m/h (nor) for the micro switch type (AM9 /M_) Table No. Description Material class Tapered tube SCS/L SS Float assembly L SS/MA7 Flange 0 SS Float guide SCS/L SS Stopring SS Indicator ADC Material class SCS/L SS L SS/MA7 L SS SCS/L SS SS ADC TOKYO KEISO CO., LTD. TG-F0-9E
15 SELECTION OF FLOWMETER. LIQUID APPLICATION a. Selection of meter size The maximum flow rate of each meter size is shown in "DIMENSIONS, MATERIAL, PRESSURE DROP, FLOW RATE TABLE." These fig ures are based on water flow (Density.0g/cm and Viscosity.0MPa s). If actual fluid condition is different from such figures, a conversion calculation is required as following formula: Qw = Q.9 / (7.7/ ρ ) - Qw : Water converted flow rate (m /h) Q : Flow rate of actual fluid (m /h) ρ ; Density of actual fluid (g/cm ) Example Fluid: Alcohol Density: 0.8g/cm Flow rate: 0m /h Flowmeter to be used: AM9 Qw = 0.9 / (7.7/0.8) - = =. m /h You will find required meter size to be 80 which covers above converted flow rate from table. Please refer to "AVAILABLITY OF CON- NECTION SIZE" for the possible connection size applied for the required meter size. Consult TOKYO KEISO Co., Ltd. for high viscosity services. b. Slurry application For slurry services such as liquids containing precipitates, particles, sands, the flowmeters suitable for slurry liquids are available. Consult TOKYO KEISO Co., Ltd. for details.. GAS APPLICATION Use the flowmeter with a gas damper unless otherwise specified to avoid a hunting, model AM9 /DU. Selection of meter size The flow rate of air in table (rated flow rate table) for AM9 /DU with a gas damper is the one converted into the unit of m /h (nor) from the flow rate of air which is measured at the conditions of 0ºC and atm. If actual fluid condition is different from such figures, a conversion calculation to be performed by the following formula: QA = Q 0.0 ρ (7+t) / (0.0+p) QA : Converted flow rate in air 0C, atm [m /h(nor)] Q : Flow rate of gas to be measured [m /h(nor)] ρ : Density of gas to be measured [kg/m (nor)] p : Pressure of gas to be measured (MPa) t : Operating temperature ( C) Example Gas to be measured : Nitrogen (N) Density ( ρ ) :.kgf/m (nor) Operating pressure ( p ) : 0.MPa Operating temperature ( t ) : 0 C Flow rate of gas to be measured (Q) : 00 m /h(nor) Flowmeter with a gas damper to be used : AM9 /DU QA = (7+0) / (0.0+0.) = =. m /h (nor) You will find required meter size to be which covers above converted flow rate from table. Please refer to "AVAILABLITY OF CONNEC- TION SIZE" for the possible connection size applied for the required meter size. TG-F0-9E TOKYO KEISO CO., LTD.
16 . STEAM APPLICATION Use the flowmeter with a gas damper unless otherwise specified to avoid a hunting, model AM9 /DU. Selection of meter size Steam flow rate is to be converted into air flow rate by the following formula for size determination. QA = Qs 0.89 ρ QA : Air flow rate at 0 C, atm converted from steam [m /h(nor)] Qs : Steam flow rate (m /h) ρ : Density of steam (kg/m ) Example Fluid : Saturated steam Pressure : 0.9MPa Flow rate : t/h Flowmeter with a gas damper to be used : AM9 /DU First, density of the steam is to be obtained from Steam graph etc. In this application, density(ρ) of 0.9MPa steam is.kg/m. Saturated steam curve (by temperature) is shown in the figure below and saturated steam curve (by pressure) is on Fig. 0 for reference. Normally, flow rate of steam is described in weight unit, which is to be converted to volume unit (Qs) as follows: QA = = 9.97 = 7 m /h (nor) You will find required meter size to be 0 which covers above converted flow rate from table. Please refer to "AVAILABLITY OF CONNECTION SIZE" for the possible connection size applied for the required meter size. Density of saturated Steam(by temperature) Density of saturated Steam (by pressure) Density [kg/m ] Density [kg/m ]. Steam temp. [ C] Steam press. [MPa] TOKYO KEISO CO., LTD. TG-F0-9E
17 . SCALE GRADUATION Customers can select the scale graduations of which maximum flow rate is between maximum flow rate of the chosen meter size and the one of one-rank-smaller meter size from the following kinds of standard graduations. The range of graduations, rangeability is 0 :. Example If required scale range is 0 00 m /h (nor), the graduation on the flowmeter will be 0 0 m /h (nor) Standard scale graduation. SPECIAL ORDERS a. Low pressure drop version If standard pressure drop does not meet the requirement, Low pressure drop version from AM7000 series is available on request. Consult TOKYO KEISO Co., Ltd. for further details. b. Low temperature application If the fluid temperature is very low (i.e. liquefied gas etc.), Special arrangement to prevent frost from AM7000 series is available. Consult TOKYO KEISO Co., Ltd. for further details. c. High pressure application TOKYO KEISO Co., Ltd. has the manufacturing record of max. 9 MPa from AM7000 series. Contact us. TG-F0-9E TOKYO KEISO CO., LTD. 7
18 CAUTIONS This flowmeter transmits the displacement caused by the magnet coupling. A surrounding magnetic field might affect its performance. Avoid installation near magnetic fields. Magnetic materials including insulation covers may also affect its performance; do not bring them within 0 cm from the flowmeter. When installing two or more flowmeters, place them at least the distances shown in the figures below apart from each other to avoid mutual interference. For maintenance, ensure a clearance of at least 0 cm between the indicator of one flowmeter and the body of other flowmeters. Local indication and alarm output type Electric transmitter and PROFIBUS PA type Local integration type For a meter size of 0 or less: at least cm For a meter size of or more: at least cm For a meter size of 0 or less: at least cm For a meter size of or more: at least cm For a meter size of 0 or less: at least 0 cm For a meter size of or more: at least 0 cm At least 0 cm At least 0 cm At least 0 cm * Specification is subject to change without notice. Head Office : Shiba Toho Building, 7 Shibakoen, Minato-ku, Tokyo 0 88 Tel : +8- (KEY) ; Fax : overseas.sales@tokyokeiso.co.jp ; URL : 8 TG-F0-9E
AM-2000 series HYBRID FLOWMETER
AM- series HYBRID FLOWMETER OUTLINE AM- series is a new all metal type flowmeter. AM- series integrates formerly separate functional devices to facilitate mounting in restricted spaces. Suitable for liquid,
More informationO-1000 Series ORIFLOMETER MOST COST EFFECTIVE FLOW MEASUREMENT GENERAL STANDARD SPECIFICATIONS TYPES AND FUNCITON
MOST COST EFFECTIVE FLOW MEASUREMENT O-1000 Series ORIFLOMETER GENERAL O-1000 series ORIFLO METER is a flow meter consisting of an orifice plate and a metal tube variable area flow meter. Since the flow
More informationR-101-E GLASS TUBE FLOWMETER BEST COST PERFORMANCE GENERAL STANDARD SPECIFICTION. Max. fluid press. MPa Meter size.
BEST COST PERFORMANCE R-1-E GLASS TUBE FLOWMETER GENERAL R-1-E is a glass tube type variable area flowmeter. The flow rate is indicated by the position of float and the graduation engraved on the glass
More informationVFM4070C SWIRLMAX. Vortex Flowmeter OUTLINE FEATURES OPERATING PRINCIPLE STANDARED SPECIFICATION. General Specification. Sensor Specification
SWIRMAX VFM4070C Vortex Flowmeter OUTINE SWIRMAX is 2-wire, all-in-one type vortex flowmeter with both temperature and pressure sensors integrally mounted into the housing. It allows temperature and pressure
More informationSRT1000 Series THERMAL FLOWMETER
High-performance gas flowmeter SRT1000 Series THERMAL FLOWMETER OUTLINE Based on the long experienced know-how on the TOKYO KEISO's thermal flowmeters, SRT1000 series has enhanced its performance such
More informationO-180/780 Series ORIFLO METER COST EFECTIVE FLOW MEASUREMENT FOR LIQUIDS AND GASES GENERAL FEATURES MAIN APPLICATIONS
COST EFECTIVE FLOW MEASUREMENT FOR LIQUIDS AND GASES O-18/78 Series ORIFLO METER GENERAL O Series ORIFLO METER is a By-pass Orifice type flowmeter. Small sized variable flowmeter is installed onto measuring
More informationMetal tube variable area flowmeter for gases, liquids and steam
Metal tube variable area flowmeter for gases, liquids and steam Metallic or plastic tube with a robust construction Indication by means of magnetic coupling Scales calibrated in l/h, m 3 /h, kg/h, t/h,
More informationEGM5300C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification
MAGMAX EGM53C Compact Electromagnetic Flowmeter GENERAL MAGMAX EGM53C is a combination of EGS5 primary head with Ceramic measuring tube and high performance converter EGC3. EGM53C with high durability
More informationMASSMAX 1000 Series Straight twin tube Coriolis Mass Flowmeter
MASSMAX Series Straight twin tube Coriolis Mass Flowmeter OUTLINE MASSMAX series is the coriolis mass flowmeters developed on the theme of the straight tube model which is excellent in cost performance.
More informationEGM1100C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification
EGMC Compact Electromagnetic Flowmeter GENERA MAGMAX EGMC is the compact type electromagnetic flowmeter with a converter EGC mounted integrally on a primary head EGS lined with fluorocarbon resin PFA.
More informationFT-1000/FP-1000 FLOAT TYPE TANK GAUGES SIMPLE, RELIABLE, COST EFFECTIVE. The FT-1000 or FP-1000 series is a mechanical level gauge with a float.
SIMPLE, RELIABLE, COST EFFECTIVE FT-1000/FP-1000 FLOAT TYPE TANK GAUGES The FT-1000 or FP-1000 series is a mechanical level gauge with a float. The FT-1000 is a conventional float-tape level gauge with
More informationSTK2000/7400 Series. Flapper-type Flowmeter OUTLINE FEATURES PRINCIPLE STANDARD SPECIFICATIONS. Specifications of the metal measuring tube
STK2000/7400 Series Flapper-type Flowmeter OUTLINE The STK2000 and STK7400 are high-accuracy, high-performance, flapper-type flowmeters. The STK2000 is a local indication type, and the STK7400 is a local
More informationMetal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam
Metal tube flowmeters Variable area flowmeter for liquids, gases and steam Metallic or plastic tube with a robust construction Indication by means of magnetic coupling Scales calibrated in l/h, m 3 /h,
More informationORIFLO CONTENTS COST EFECTIVE FLOW MEASUREMENT FOR LIQUIDS AND GASES INTEGRATED ORIFICE FLOWMETERS GENERAL FEATURES MAIN APPLICATIONS
COST EFECTIVE FLOW MEASUREMENT FOR LIQUIDS AND GASES ORIFLO INTEGRATED ORIFICE FLOWMETERS GENERAL O series ORIFLO METER is a By-pass Orifice type flowmeter. Small sized variable flowmeter is installed
More informationUL6300 SONICMAX. Ultrasonic Clamp-on Flowmeter OUTLINE FEATURES STANDARD SPECIFICATION. Common specification
SONICMAX UL63 Ultrasonic Clamp-on Flowmeter OUTLINE SONICMAX UL63 is the ultrasonic flowmeter of the time flight system which combined the highly efficient converter (UFC3) with the clamp-on sensor (UFS6).
More informationUL6300 SONICMAX. Ultrasonic Clamp-on Flowmeter OUTLINE FEATURES MEASURING PRINCIPLE
SONICMAX UL63 Ultrasonic Clamp-on Flowmeter OUTLINE SONICMAX UL63 is the ultrasonic flowmeter of the time flight system which combined the highly efficient converter (UFC3) with the clamp-on sensor (UFS6).
More informationGlass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases
Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases Easy installation Local indication by means of direct reading Low pressure drop Scales directly in l/h, m 3 /h, kg/h, l/min,
More informationPlastic tube variable area flowmeter for liquids and gases
Plastic tube variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or fusion welding connections)
More informationBGN. All Metal Variable Area Flow Meter. Technical Data Sheet
All Metal Variable Area Flow Meter BGN Technical Data Sheet Extremely robust through star guiding system instead of guiding rod Flow metering of liquids, gases and steam Available up to nominal size of
More informationKDM ARMORED FLOW METER & SWITCH
KDM ARMORED FLOW METER & SWITCH Flow Pressure Level Temperature measurement monitoring control S2 Short Installation Length SS, PTFE or Hastelloy Wetted Parts Analog Output Available 110 F to + 390 F Temperature
More informationHDT1000 series ORIFLO METER. Multi-function Digital Flowmeter OUTLINE STANDARD SPECIFICATION FEATURES MAIN APPLICATIONS INDICATOR SPECIFICATION
ORIFO METER HDT series Multifunction Digital Flowmeter OUTINE HDT is a new series Oriflo meter combining orifice plate with multidigital indicator. HDT detects differential pressure exerted by flow velocity
More informationSmart Pressure Transmitter
DOC. NO.: C3100L-E16B Smart Pressure Transmitter with Diaphragm Seal MODEL APT3100L DUON System Co., Ltd. 298-29, GONDAN-RO, GUNPO-SI, GYEONGGI-DO, KOREA 15809 Tel : +82-31-3-6100 Fax : +82-31-29-7200
More informationTurbine flowmeters Series TM
Turbine flowmeters Series TM Suitable for liquids Possibility of installation in all flow directions Special design for high pressure available Excellent relationship flow range / flowmeter size Low pressure
More informationO-180/780 Series ORIFLO METER COST EFECTIVE FLOW MEASUREMENT FOR LIQUIDS AND GASES GENERAL FEATURES MAIN APPLICATIONS
COST EFECTIVE FLOW MEASUREMENT FOR LIQUIDS AND GASES O-18/78 Series ORIFLO METER GENERAL O Series ORIFLO METER is a By-pass Orifice type flowmeter. Small sized variable flowmeter is installed on measuring
More information1000 Series MASSMAX. Coriolis Mass Flowmeter Straight Twin Tube OUTLINE FEATURES STANDARD SPECIFICATIONS. Fluid Specifications
MSSMX Series Coriolis Mass Flowmeter Straight Twin Tube OUTLINE MSSMX series is the coriolis mass flowmeters developed on the theme of the straight tube model which is excellent in cost performance. The
More informationFP-4000 Series FLOAT LEVEL SWITCH OUTLINE MAIN APPLICATIONS STANDARD SPECIFICATION
FOR MULTIPOINT LEVEL ALARM ETECTION BY ONE UNIT FP- Series FLOAT LEVEL SWITC OUTLINE The FP- series is a float level switch, which is installe through the tank nozzle on tanks an/or pits. Level alarm etection
More informationOscillating piston flowmeters Series COVOL Positive displacement flowmeter for liquids
Oscillating piston flowmeters Series COVOL Positive displacement flowmeter for liquids Suitable for all kind of liquids Viscosity up to 120000 mpa s Excellent performance with changing process conditions
More informationFlowmeters with Float. Flow Measurement of Gases & Clear Liquids with Float Series 6001 & Series 6001/ Measurement Principle.
Flowmeters with Float Series 6001/ 6002 Flow Measurement of Gases & Clear Liquids with Float Series 6001 & 6002. Measurement Principle Variable area obtained by the displacement of a float in a conical,
More informationLevel Switch MPC2000 MPC2
Technical Information Level Switch MPC2000 MPC2 Displacement Type Level Switch Application MPC series level controllers are displacement type instruments for tank installation. MPC provides 1to 4 control
More informationOrifice plate flowmeters Series PR By-pass flowmeter for liquids, gases and steam
Orifice plate flowmeters Series PR By-pass flowmeter for liquids, gases and steam By-pass flowmeter with orifice plate (compact system PRC and separate system PR) for big flow ranges Flow indication by
More informationSS3 Linear / Rotary. Smart Valve Positioner. Smart performance with innovative and ever-strong coil drive even under harsh working environments
Smart Valve Positioner SS3 Linear / Rotary Smart performance with innovative and ever-strong coil drive even under harsh working environments Easy and quick auto-calibration Detecting RA (reverse acting)
More informationRosemount 3051T In-Line Pressure Transmitter
Rosemount 3051T In-Line Pressure Transmitter Rosemount 3051T In-line Pressure Transmitters are the industry standard for Gage, and Absolute pressure measurement. The in-line, compact design allows the
More informationAP ATEX AIRPOWER POSITIONERS AP2000 FEATURES AP1000 & AP1200 FEATURES OPTIONS OPTIONS
AP1000-2000 Airpower positioners are a robust range of rotary or linear valve positioners in AP1000 electro-pneumatic (4-20mA), AP1200 pneumatic (3-15 psi) or AP2000 programmable smart type. Designed to
More informationHH5 Variable Area Flow meter
HH5 Variable Area Flow meter General Information HH5 series variable area flowmeteris a kind of measuring meter which the flow rate is changing along with the area and is widely used in the process control
More informationMagnetic Level Gauges
Magnetic Level Gauges Instrumentation Division > Immediate and accurate response to level changes, giving clear and sharp legibility. > Continuous indication of liquid level. The well proven TC Fluid Control
More informationSmart Pressure Transmitter
DOC. NO.: C3500L-E16A Smart Pressure Transmitter with Diaphragm Seal MODEL APT3500L 298-29, GONDAN-RO, GUNPO-SI, GYEONGGI-DO, KOREA 15809 Tel : +82-31-3-6100 Fax : +82-31-29-7200 E-mail: autrol@duon.co.kr,
More informationMetal tube flowmeters Series M21 Variable area flowmeter for low flows of liquids, gases and steam
Metal tube flowmeters Series M21 Variable area flowmeter for low flows of liquids, gases and steam Metallic tube with a robust construction Indication by means of magnetic coupling Scales calibrated in
More informationO-100 Series GLASS TUBE TYPE ORIFLOMETER BEST COST EFFECTIVE FLOW MEASUREMENT EVEN FOR LARGE SIZE LINES GENERAL STANDARD SPECIFICATION MODEL CODE
BEST COST EFFECTIVE FLOW MESUREMENT EVEN FOR LRGE SIZE LINES O-0 Series GLSS TUBE TYPE ORIFLOMETER GENERL O-0 series ORIFLO METER is a flow meter consisting of a orifice plate and a GLSS TUBE type variable
More informationCDT1000 Series QUICK FLOW. Digital Flowmeter for Air Conditioning Application OUTLINE FEATURES STANDARD SPECIFICATION
QUICK FLOW CDT1 Series Digital Flowmeter for Air Conditioning Application OUTLINE CDT1 is a new series of flowmeter which combines a multidigital indicator with a pitot tube. CDT1 detects the differential
More informationThe EPSILON is based on the principle of measuring velocity in the pipe line, therefore the flow measurement is volumetric.
Typical Applications EPSILON Flowmeter The EPSILON flow meters measure the flow of most liquids and gases within the process industries, including chemical, petro-chemical, pharmaceutical and the power
More informationSmart Valve Positioner 700 Series with HART Communication Protocol
No. SS2-AVP702-0100 Smart Valve Positioner 700 Series with HART Communication Protocol OVERVIEW The Smart Valve Positioner 700 Series (model number: AVP7**) not only inherits the reliability of the core
More informationRosemount 3051CFA Annubar Flowmeter
December 2013 Rosemount 3051 Rosemount 3051CFA Annubar Flowmeter The Rosemount 3051CFA Annubar Flowmeter utilizes the patented T-shaped sensor design that delivers best in class accuracy and performance.
More informationJUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram
Data Sheet 403025 Page 1/10 JUMO dtrans p20 Process pressure transmitter Brief description The JUMO dtrans p20 pressure transmitter with HART interface combines maximum precision with easy operation. It
More informationSATRON VT Pressure Transmitter
SATRON VT pressure transmitter belongs to the series V-transmitters. SATRON VT is used for 0-1.4 kpa...0-100 MPa ranges. It is a 2-wire transmitter with HART standard communication. In pressure measuring
More informationSATRON VDt Differential Pressure Transmitter
SATRON VDt differential pressure transmitter belongs to V-transmitter family. The series V transmitters have both analog and smart properties. SATRON VDt is used for -,1kPa...-15 MPa ranges. It is a 2-wire
More informationSP/SF Series Flow Switches
ISO-9001:2000 certified SP/SF Series Flow Switches More than just another level measurement company. Aplus Finetek Sensor, Inc. PRODUCT INTRODUCTION SP SERIES OPERATING PRINCIPLE SP SERIES The SP Series
More informationSmart Valve Positioner 700 Series with HART Communication Protocol
No. SS2-AVP702-0100 Smart Valve Positioner 700 Series with HART Communication Protocol OVERVIEW The Smart Valve Positioner 700 Series (model number: AVP7**) not only inherits the reliability of the core
More informationHG5 Series. Metal Tube Rotameter CATALOG MAIN FEATURES TECHNICAL PARAMETERS
H5 Series Metal Tube Rotameter H5 series metal tube rotameter (also called variable area flow meter) is a kind of measuring meter which the flow rate is changing along with the area and is widely used
More informationEDR-N8A CS Intelligent Absolute Pressure Transmitter STANDARD SPECIFICATIONS. Accuracy Material Code: Standard,316L Range Accuracy Code
Intelligent Absolute Pressure Transmitter Absolute Pressure Transmitter incorporates semiconductor sensors and a microcomputer and converts measured s to 4 to 20mA DC signal with high accuracy. is suitable
More informationABB Instrumentation. 50T Series Transmitters Model 54G/A gauge/absolute pressure transmitter for sanitary use. Specification sheet
Specification sheet 50T Series Transmitters Model 54G/A gauge/absolute pressure transmitter for sanitary use Ranges : - 100 to 4000 kpa - 1 to 40 bar - 14.5 to 600 psi Base accuracy : 0.2%(BFSL) Piezoresistive
More informationDesign and application
Design and application The function of the SGM is based on the variable area float principle. In all cases where a dependable device is required for indicating instantaneous values and monitoring the flow
More informationSmart Pressure Transmitter
DOC. NO.: C3200L-E16B Smart Pressure Transmitter with Diaphragm Seal MODEL APT3200L DUON System Co., Ltd. 298-29, GONDAN-RO, GUNPO-SI, GYEONGGI-DO, KOREA 15809 Tel : +82-31-3-6100 Fax : +82-31-29-7200
More informationSTEEMCO-MAS Flowmeter for Steam
STEEMCO-MAS Flowmeter for Steam Typical Applications The STEEMCO-MAS flow meters measure the mass flow of superheated steam within the process industries, including chemical, petro-chemical, pharmaceutical
More informationVortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S) For flow rate and volume measurement of liquids, gases and steam
Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S) For flow rate and volume measurement of liquids, gases and steam Cost savings due to high accuracy Low investment cost through
More informationMagnetic Level Gauges
Magnetic Level Gauges Instrumentation Division > Immediate and accurate response to level changes, giving clear and sharp legibility. > Continuous indication of liquid level. The well proven TC Klinger
More informationK Series 3 Way Direct Acting Balanced Poppet Solenoid Valve
Ex d Ex m IP5 Series 3 Way Direct Acting Balanced Poppet Solenoid Valve DB2S-M2C \ Ex d IIC with Integral Stainless \ Steel Junction Box. \ Valve. \ Manual Override, Option M2. J77072S-M2 \ Ex m II NASS
More informationFlowmeters Selection Guide
CA2-5100 Calibration Facility for water The flow calibration rig in Kyoto has the only two-stage elevated water tank system in Japan. At a height of 35m, the tanks are also the highest in Japan. It can
More informationDifferential Pressure Gauges Cryo Gauge Model , Cu-alloy Model , Stainless Steel Series
Differential Pressure Gauges Cryo Gauge Model 712.15.160, Cu-alloy Model 732.15.160, Stainless Steel Series Mechanical Pressure Measurement WIKA Data Sheet PM 07.30 Applications Level measurement in closed
More informationSTANDARD SPECIFICATIONS
CFW1000 C C C C CFW1000 CFW1 Description Installation 2 Horizontal type 4 Vertical Indicator 1 20 C water calibration 2 7 C and 60 C water, double scale 1 Scale range 1 See right table Scale range 2 Scale
More informationAPS & APIS ATEX AIRPOWER SWITCH BOXES FEATURES DESCRIPTION
page 1 DESCRIPTION The switch boxes are suitable for rotary actuators and are the industry leader in versatility, quality and approvals gained. Models include APS standard range with a variety of outputs
More informationJUMO dtrans p20 DELTA
Data Sheet 403022 Page 1/9 JUMO dtrans p20 DELTA Differential pressure transmitter Brief description The JUMO dtrans p20 DELTA differential pressure transmitter with HART interface combines maximum precision
More informationSmart Displacement type Level Transmitter
No. SS-SLX100-0100 Smart Displacement type Level Transmitter model SLX OVERVIEW The SLX series is a complete line of highly accurate and reliable high-performance torque tube type displacement level transmitters
More informationPOSITIONERS and Controls for Complete Valve Automation
CONTROLS A Division of AT Controls Pneumatic & Electro-Pneumatic POSITIONERS and Controls for Complete Valve Automation 1 SS SERIES SS Features Easy and quick auto-calibration Detecting RA (reverse acting)
More informationUser's Manual Models SE100MJ/NJ and SE200MJ/NJ Integral Type Magnetic Flowmeter
User's Manual Models SE100MJ/NJ and SE200MJ/NJ Integral Type Magnetic Flowmeter Manual Change No. 09-001-5E Please use attached sheets for the pages listed below in (10th). Page Page 10-2 EMC Conformity
More informationMagnetic-inductive flow meter for hazardous areas
Magnetic-inductive flow meter for hazardous areas Technical Datasheet EPX / UMF3 high accuracy: 0.3 % of actual maintenance-free no pressure drop numerous lining materials numerous electrode materials
More informationVortex Flowmeters VFM 3100 F-T VFM 3100 W-T
KROHNE 10/2001 7.02313.23.00 GR/OP Vortex Flowmeters F-T W-T Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters Level measuring
More informationRCM - Direct Reading Flowmeters
Compact Design Easy to Install Horizontal or Vertical Installation Flow Rates up to 3000 GPM (Liquid) or 20000 SCFM (Gas) Low Pressure Drop Optional Alarms and Output Signals Accuracy: ± 3% of full scale
More informationST3000 Series 900 Smart Transmitter Differential Pressure Transmitters
ST3000 Series 900 Smart Transmitter Differential Pressure Transmitters Model STD910/STD920/STD930/STD960/STD921/STD931/STD961 OVERVIEW The ST3000 Smart Transmitter is a microprocessor-based smart transmitter
More informationSeries 60. New Smart Positioner. Compact design Convenient & powerful function Enhanced reliability
Series 60 New Smart Positioner Compact design Convenient & powerful function Enhanced reliability J Flow Controls, LLC 14 De Camp Cincinnati, OH 45216 Phone: 513-731-2900 Fax 513-731-6939 www.jflowcontrols.com
More informationSatellite photo of cloud vortices caused by a mountain (Courtesy of our friends at NASA) tekvorx Operation Showing Simplified Construction
Sensing the pulse of industry tekvorx TV01 Multivariable Vortex flow Sensors Vortex flow sensors derive their name from a natural phenomenon of fluid dynamics. When a gas or relatively low viscosity liquid
More informationUL350 ULTRASONIC FLOWMETER CLAMP-ON TYPE OUTLINE FEATURES MEASUREMENT PRINCIPLE
CLMP-ON TYPE UL350 ULTRSONIC FLOWMETER OUTLINE Our clamp-on type Ultrasonic Flowmeter UL350 has enabled applications to piping in various kinds by enhancing the permeation property of ultrasonic wave.
More informationMasoneilan Series
Masoneilan 12300 Series Digital Level Transmitter & Controller Specification Data CU3000 02/02 Digital Level Measurement and Control Instrumentation Table of Contents General Description...2 Principle
More informationTORRIX Magnetostrictive level sensor
TORRIX Magnetostrictive level sensor Precision Versatility Security Sensors & Systems Worldwide: www.fafnir.com FAFNIR Quality and Satisfaction Company: Based in Hamburg, Germany, FAFNIR GmbH has over
More informationProcess resistance thermometer Model TR12-B, for additional thermowell Model TR12-M, basis module
Electrical temperature measurement Process resistance thermometer Model TR12-B, for additional thermowell Model TR12-M, basis module WIKA data sheet TE 60.17 for further approvals see page 6 Applications
More informationTemperature Indicating Controller
\ KF Series Temperature Indicating Controller Model KFT OVERVIEW The KF Series instruments are field-installed type of pneumatic indicating controllers which are used to measure and control the various
More informationOptions guide. Electromagnetic flowmeters. M9xx
Options guide Electromagnetic flowmeters M9xx Ordering codes Model Description M 910 -V0 0 0 0 DN50 PN16 Example Sensor M Basic Ex Ex certified (remote version only) Transmitter 910E Economic version 910
More informationBFS-10-O G1/4: BFS-10-O G1/2: BFS-10-O G1: Contact rating: BFS-10-O G1/4
Flow Switches Index: B / 923-1838 BFS-10-N / BFS-10-O for monitoring liquids, with or without optical display Features set point continuously adjustable rugged, low hysteresis, any mounting position, high
More informationLevel Limit Switch liquiphant FTL 365 / FTL 366
Technical Information TI 86F/00/en Level Limit Switch liquiphant FTL 65 / FTL 66 Level limit switch Liquiphant II with vibrating probe. For all types of liquid. With explosionproof housing for use in hazardous
More informationWaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB
WaterMAG Electromagnetic Flowmeter for Water Applications OVERVIEW The WaterMAG is an electromagnetic flowmeter for water measurement applications based on field proven Azbil Corporation's technologies.
More informationCAPACITIVE LEVEL SWITCHES. Capacitive switch catalogue HYC-CSC01 Elect. Iss. 01
CAPACITIVE LEVEL SWITCHES Capacitive switch catalogue HYC-CSC01 Elect. Iss. 01 HYCONTROL CAPACITIVE LEVEL SWITCH RANGE Hycontrol ME capacitive level switches provide simple, accurate and reliable level
More informationResistance thermometer Model TR10-E, for additional thermowell
Electrical temperature measurement Resistance thermometer Model TR10-E, for additional thermowell WIKA data sheet TE 60.05 further approvals see page 6 Applications Chemical industry Petrochemical industry
More informationSTEEMCO Flowmeter for Steam
STEEMCO Flowmeter for Steam Typical Applications The STEEMCO flow meters measure the flow of saturated and superheated steam within the process industries, including chemical, petro-chemical, pharmaceutical
More informationVORTEX FLOW METTER DVH. Despriction. Advantages of the DVH Vortex Flow Meter
R VORTEX FLOW METTER DVH Measuring range: 3-8... 3 057-280 187 m3n/h Accuray: ± 0,7 % of reading (liquids) ± 1 % of reading (gases and steam) P m a x : 100 bar abs; tm ax : 400 C Connection: ANSI ½ up
More informationQUALITY INDUSTRIAL FLOWMETERS
QUALITY INDUSTRIAL FLOWMETERS COMPANY PROFILE Trimec Industries is an Australian owned ISO9001:2008 quality certified company specializing in the design and manufacture of a proprietary range of positive
More informationMobrey MLT100. Displacer Level Transmitter. Product Data Sheet February 2015 IP119, Rev CA. Level, contents or interface measurement transmitter
Product Data Sheet February 2015 IP119, Rev CA Displacer Level Transmitter Level, contents or interface measurement transmitter Direct or external chamber mounting 4 20 ma HART output ATEX Intrinsically
More informationSystem Electropneumatic Converters (Proportional Valves) Electronic Process Controllers Signal Converters
System 6000 Electropneumatic Converters (Proportional Valves) Electronic Process Controllers Signal Converters Edition April 2018 Information Sheet T 6000 EN Electropneumatic Converters i/p converters
More informationmass flowmeter for compressed air
mass flowmeter for compressed air VARIOMASS ECO pressure and temperature compensated easy and cost effective installation of the sensor no pressure loss caused by the sensor no moving parts, i.e. maintenance
More informationDescription. Fieldbus Optimized Through Junction Boxes
Easy and safe connection for sensors, actuators and measuring instruments to the fieldbus - Foundation TM fieldbus, PROFIBUS-PA or HART Rugged assembly for industrial and hazardous areas Reduces wiring
More informationPressure transmitter JUMO dtrans p02
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 609 Fulda, Germany Postal address: 605 Fulda, Germany Phone: +49 661 600-0 Fax: +49 661 600-607 e-mail: mail@jumo.net Internet: www.jumo.net JUMO
More informationMETAL VAREA-METER STRAIGHT THROUGH TYPE ROTAMETER
TECHNICAL INFORMATION METAL VAREA-METER STRAIGHT THROUGH TYPE ROTAMETER Electronic Transmitter INTRODUCING THE METAL TUBE VAREA-METER U.S. Filter/Wallace & Tiernan Products straight through metal tube
More informationMagneW Neo+ Two-wire Electromagnetic Flowmeter Integral type TIIS Explosion-protected Apparatus
MagneW Neo+ Two-wire Electromagnetic Flowmeter Integral type TIIS Explosion-protected Apparatus OVERVIEW The MagneW Neo+ is a high performance two wired electromagnetic flowmeter based on field proven
More informationBM 26 BASIC/ADVANCED Technical Datasheet
BM 26 BASIC/ADVANCED Technical Datasheet Magnetic bypass Level Indicator (MLI) for generalpurpose applications Best price / performance ratio Full stainless steel construction IP68 local indicator with
More informationOM004, OM006 & OM008 Oval Gear Meter
OM SERIES OM004, OM006 & OM008 Oval Gear Meter OM004 (1/8"), OM006 (1/4") and OM008 (3/8") Oval Gear Meters ACCURACY: ±1.0% OF READING Select Your Body Material: Aluminum or Stainless Steel The OM Small
More informationLevel Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd
Pointek CLS200 Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable choices liquids, solids,
More informationFlow switches Series AD/VH
Flow switches Series AD/VH Flow switch and indicator for liquids and gases Suitable for clear, opaque or turbid liquids (series AD & VH), and for gases (series AD) Flow switching by means of magnetic coupling,
More informationQUALITY INDUSTRIAL FLOWMETERS
QUALITY INDUSTRIAL FLOWMETERS COMPANY PROFILE Trimec Industries is an Australian owned ISO9001:2008 quality certified company specializing in the design and manufacture of a proprietary range of positive
More informationORIMAS Mass Flowmeter
Typical Applications ORIMAS Mass Flowmeter The ORIMAS mass flow meters measure the mass flow of most liquids and gases within the process industries, including chemical, petro-chemical, pharmaceutical
More informationINLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1
INLINE Flow sensor for hazardous area II G/D - II D - II GD - I M Type SE0 Ex can be combined with... Flow meter with NAMUR or NPN/PNP output signal Mounting, dismounting of electronics by a Quarter-Turn
More informationSensor boxes SRBE Key features and product range overview
Sensor boxes SRBE Sensor boxes SRBE Key features and product range overview Function Sensor boxes SRBE are used for electrical feedback and control of the position of process valves actuated using pneumatic
More informationLevel Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.
Pointek CLS200 Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable choices liquids, solids,
More information