1 ort Solenoid Valve ubber Seal Series SY00 Low power consumption: 0.W (Standard, Without light) (Current draw: m at V DC) Large flow capacity style:0.7w (Current draw: m at V DC) Body width: 0mm 7.8 Nl/min (Standard style).78 Nl/min (Large flow capacity style) Exceedingly long life 00 million cycles (By SMC life test data) SY SYJ VK VZ V VG VQ VQZ Vacuum pplications ossible Can be used up to -00ka Copper free No copper used for sections in contact with fluids. Bright colour tone and "state of the art" design bright grey concept has been adopted for this product to complement the surrounding operational environment. SY00/ pplication example (neumatic symbols shown are typical examples.) qvalve for blow off wvalve for vacuum eoperation for single acting cylinder roperation for air operated style fluid control valve () () N.C. () Vacuum valve () () N.O. Vacuum pad () () () tmospheric air or micro pressure for vacuum release N.C. () () () N.C. () ir operated style fluid control valve Characteristics values indicated in this catalog are not guaranteed values but typical ones..-

2 Series SY00 recautions Be sure to read before handling. efer to p.0- to 0- for Safety Instructions and common precautions. Warning Operation of Manual Override Make sure that there is no danger, since manual override operation can make any connected equipment operate. Non-locking push style [Standard style] Locking slotted style [B] ress in the direction of the arrow. Turn in the direction of arrow. wcrimping connection of and socket Strip. to.7mm of the ends, insert each stripped wire into a socket and crimp contact it using special crimping tool. Be careful that the outer insulation of the s does not interfere with the socket contact part. Use exclusive crimping tool for crimping. (Contact SMC for special crimping tool.) Core wire contact area Socket Crimping area Core wire Lead wire 0. to 0.mm Max. covered O.D.: ø.7mm Hook Insulation ush-locking slotted style [D] L 0 ush-locking lever style [E] ressing makes the valve operate. The valve can be locked in the manual override position by turning it to the direction that the arrow shows while keeping it pressed. If it is not turned, it can be used as a non-locking push style. L econnection/disconnection of socket with Connection Insert and crimped socket into square holes (indicated as, B, COM) of connector. ress the socket in fully until the hook of the socket locks into the groove of the connector housing. Confirm the locked position by lightly pulling on the. Disconnection To remove the socket from the connector, pull out lead wire while depressing the hook of the socket with a fine screw driver ( mm). If the socket is to be re-used, reposition the hook again. Socket Hook Connector housing Lead wire Caution How to Use lug Connector qconnection/disconnection of connector Connection: ush the connector straight onto the pins of the solenoid, making sure the lip of the lever securely locks into the groove of the solenoid cover. Disconnecton: ress the lever against the connector housing and pull it outward from the solenoid. Cover Groove in Caution Gently operate locking manual override styles B, D using small screwdriver. [Torque: 0.Nm or less] Cover Groove in Lever DC indicator Socket DXT70-7- lug Connector Lead Wire Length Standard length is 00mm, but the following lengths are also available. How to Order Connector ssembly For DC: Without : (Only with a connector and two sockets.) SY00 0 SY00 0 How to Order To order a valve with length of other than 00mm, indicate part numbers of the valve without connector and the required connector ass'y separately. Example: 00mm length For DC SY-LO SY Lead wire length mm 00mm 000mm 00mm 00mm 0mm 000mm 000mm Connector housing Hook Lead wire.-

3 Series SY00 Surge Voltage Suppressor <DC> Grommet, L and M plug connector Standard style (With polarity) With surge voltage suppressor ed (+) Black ( ) ed (+) Black ( ) Diode to prevent reverse connection Coil Indicator light and surge voltage suppressor ( Z) Diode to prevent reverse connection Coil Non-polar style With surge voltage suppressor (" ") ( ) (+) (+) ( ) ( ) (+) (+) ( ) lease connect correctly the s to (positive) and (negative) indications on the connector. For non-polar style, the s can be connected to either one. For DC voltages other than, V DC, incorrect wiring will cause damage to the surge voltage suppressor circuit. (Wrong polarity will cause trouble.) Solenoids, whose s have been pre-wired: positive side red and negative side black. Caution Zener diode Coil Indicator light and surge voltage suppressor (" U") Zener diode Since there is some residual voltage according to the protection device and rated voltage in case of voltage surge suppressor by zener diode, pay attention to the surge protection on the controller side. (Diode residual voltage: V) Coil Connector ssembly with rotective Cover Connector assembly with protective cover enhances dust protection. Effective in preventing possible short circuit problems due to contaminants in contact with connector section. Cover material is chloroprene rubber which has excellent weatherability and electric insulation properties. However, be careful not to allow contact with cutting oil. ound cord provides neat appearance. How to Order SY00 8 Lead wire ( L ) mm 00mm 000mm 00mm 00mm 0mm 000mm 000mm Connector ssembly with Cover/Dimension (8) (.) (0) (0) ed Black (.) L Gray How to Order Indicate part number of connector assembly with cover in addition to the solenoid valve part number without connector of the plug connector. <Example > Lead wire length: 00mm SY-LOZ-M-Q SY <Example > Lead wire length: 00mm (Standard) SY-LZ-M-Q Symbol of connector assembly with cover (.) No part numbers of connector assembly with cover are needed to be indicated in this case. (8) SY SYJ VK VZ V VG VQ VQZ.-

4 ort Direct Operated ubber Seal Series SY00 Model Body ported ctuation N.C. N.C. N.O. N.O. Model SY SY SY () SY Specifications () Style Standard Large flow capacity Standard Large flow capacity Operating pressure range (Ma) 0 to to to to 0.7 Vacuum application (Ma) Weight (g) () Effective area port port (mm ) (Nl/min) Grommet style 00ka to 0. 00ka to 0. 00ka to 0 00ka to 0 00ka to 0 00ka to 0 00ka to 0. 00ka to (7.8) 0. (.78) 0. (7.8) 0. (.78) SY (): SY (): Without sub-plate L, M lug connector SY (): SY (): Without sub-plate Note ) SY/SY and SY/SY : Supply pressure to () port and exhaust air from () port. Note ) Value for DC. Base mounted Fluid mbient and fluid temperature ( C) esponse time (ms) () Max. operating frequency (Hz) Manual override ir Max. 0 C 0ms or less Non-locking push, Locking slotted, ush-locking slotted, ush-locking lever JIS Symbol SY () SY () Order Made () () ()..- () () () Lubrication Mounting position Impact/Vibration resistance (m/s) () Enclosure Not requited Free 0/0 Dust-proof Note ) ccording to dynamic performance test JIS B87-8 (Coil temperature C, at rated voltage, without surge suppressor.) Note ) Impact resistance: No malfunction from tests using drop impact tester, to axis and right angle direction of main valve and armature, each one time when energized and de-energized. (Value in the initail stage) Vibration resistance: No malfunction from tests with 8.~00Hz sweep, to axis and right angle direction of main valve and armature, each one time when energized and de-enegized. (Value in the initial stage.) Solenoid Specifications Series Electrical entry Coil rated voltage (V) DC SY SY Grommet (G), (H), L plug connector (L), M plug connector (M),,,, llowable voltage ower consumption (W) () Surge voltage suppressor Indicator light () t rated voltage DC 0 to +0% 0.W (With light: 0.W) 0.7W (With light: 0.8W) Diode LED.-

5 0 L L Series SY00 How to Order Standard (7.8 Nl/min) Light and surge voltage suppressor S Z U Without light and surge voltage suppressor With surge voltage suppressor With light and surge voltage suppressor With light and surge voltage suppressor (Non-polar style) SY iping Bracket SYJ port For manifold type 0, Standard : Body ported (Nl/min: 7.8) ctuation Normally closed Normally open SY L : For manifold : For body ported style to,, port M -Q : Without bracket F: With bracket "" piping specification only. VK VZ V VG Standard : Base mounted (Nl/min: 7.8) SY M -Q port Sub-plate style For manifold type S ated voltage V S Order Made V DC V DC V DC V DC V DC 0V or less Contact SMC for other voltages () iping port : Without sub-plate M: With sub-plate VQ VQZ (With gasket and screw) Electrical entry V, V, V, V, V DC Grommet L plug connector M plug connector G: 00mm L: 00mm M: 00mm MN: Without Manual override : Non-locking push style D: ush-locking slotted style H: 00mm LN: Without LO: Without connector MO: Without connector B: Locking slotted style E: ush-locking lever style LN or MN option includes sockets. SY/SY, SY/SY only. rotective class class III (Mark: ).-

6 0 L L Series SY00 How to Order Large flow capacity (.78 Nl/min ) Light and surge voltage suppressor S Z U Without light and surge voltage suppressor With surge voltage suppressor With light and surge voltage suppressor With light and surge voltage suppressor (Non-polar style) port iping : For manifold : For body ported style to,, port Bracket : Without bracket F: With bracket For manifold type 0, ctuation Normally closed Normally open "" piping specification only. Large flow capacity : Body ported (.78 Nl/min) SY L M -Q Large flow capacity : Base mounted (.78 Nl/min) SY M -Q port Sub-plate style For manifold type S ated voltage V S Order Made V DC V DC V DC V DC V DC 0V or less Contact SMC for other voltages () iping port : Without sub-plate M: With sub-plate Large flow capacity (With gasket and screw) Electrical entry V, V, V, V, V DC Grommet L plug connector M plug connector G: 00mm L: 00mm M: 00mm MN: Without Manual override : Non-locking push style D: ush-locking slotted style H: 00mm LN: Without LO: Without connector MO: Without connector B: Locking slotted style E: ush-locking lever style LN or MN option includes sockets. SY/SY, SY/SY only..- rotective class class III (Mark: )

7 Series SY00 Construction SY, SY () ()() i q y e r w SY SYJ VK VZ! o u t!0 V VG VQ VQZ Component arts No. q w e r t y u i o Description Body Cover ush rod rmature ass'y Core Exhaust poppet eturn spring oppet spring Coil ass'y Material esin esin esin NB/Stainless steel Stainless steel NB Stainless steel Stainless steel Notes Gray Gray eplacement arts No.!0! Description Sub-plate Gasket art No. SY00-7--Q VJ00---Q Material Zinc die cast NB How to Order Connector ssembly For DC: SY00 0 Without : (Only with a connector and two sockets.) SY00 0 Lead wire mm 00mm 000mm 00mm 00mm 0mm 000mm 000mm.-7

8 Series SY00 Body orted G Grommet (G), (H): SY ()- H -M (-F) -Q suppressor) Manual override G, H:. G, H : M X 0. (iping port) G: 00 H: ø.8 (Mounting holes) -ø.8 (Mounting holes) L plug connector (L): SY ()- L -M (F)-Q M plug connector (M): SY ()- M -M (-F)-Q Other dimensions are same as grommet style. 00 Other dimensions are same as grommet style. 8..

9 Series SY00 Base Mounted (With Sub-plate) G Grommet (G), (H): SY ()- H -M-Q G: 00 H: 00 0 SY G, H:. G, H :.8 -M X 0. (iping port). Monual override.... SYJ VK VZ V VG + -. VQ 8 -ø. (Mounting holes) VQZ L plug connector (L): SY ()- L -M-Q M plug connector (M): SY ()- M -M-Q Other dimensions are same as grommet style. Other dimensions are same as grommet style..-

10 Series SY00 Manifold Specifications Type Manifold style (SU)/ (EXH) style Valve stations 0 () S Single base style, B mount Common SU/Common EXH to 0 stations to stations porting Location Direction Valve Top Base Side ort size, port port M X 0. M X 0.8 M X 0., M X 0.8 SY 0. (7.8) Valve effective area mm (Nl/min) () SY SY SY 0. (.78) 0. (.87) 0. (0.8) Note ) When mounted on manifold base Note ) SY () and SY () can not be mounted on the same manifold. Note ) Supply to port and exhaust from port for SY (). Note ) 0 Type is applicable only for SY and SY. iping to exhaust port is not possible. How to Order Manifold Base (Ordering Example) Example Valve (N.C.) SY-GZ-Q Stations Blank plate assembly SY Q Manifold base ( stations) SSY-S-0-M-Q SSY-S-0-M-Q... set (S type -station manifold part number) SY Q... set (Blank plate assembly part number) SY-GZ-Q... set (Valve) List part numbers of the installed valve and option in required station location separately under manifold part number. rotective class class III (Mark: ).-0

11 Series SY00 Common SU/Common EXH 0 Type How to Order SSY 0 0 F-Q Type How to Order SSY 0 S Type port M X 0. M X 0.8 port M X 0.8 port M X 0.8 port M X 0.8 port M X 0.8 port M X 0.8 How to Order Stations 0 stations stations Note ) iping to exhaust port not possible. Stations 0 stations... SSY S 0 stations Note ) SY () and SY () cannot be mounted on the same manifold. Stations 0 stations stations -Q... M port size M M -Q M X 0. M X 0.8 Note ) SY () and SY () cannot be mounted on the same manifold. pplicable solenoid valve () SY- -M-Q SY- -M-Q pplicable blank plate assembly SY Q pplicable solenoid valve () SY- -M-Q SY- -M-Q SY- -M-Q SY- -M-Q pplicable blank plate assembly SY Q pplicable solenoid valve () SY- -Q SY- -Q SY- -Q SY- -Q pplicable blank plate assenbly SY Q rotective class class III (Mark: ) SY SYJ VK VZ V VG VQ VQZ Combination with Solenoid Valve and Gasket Manifold Base Blank late ssembly Body ported Cross round head screw SY00-- (M.7 X, Matt nickel plated) Base mounted arts No.: SY Q Cross round head screw SY00-- (M.7 X 7, Mat nickel plated) Blank plate SY Q Gasket VJ00-- Gasket VJ00--0 pplicable base Sub-plate (For body ported style) SSY-0 type Manifold base SSY- type Manifold Gasket VJ00--8 pplicable base Sub-plate SSY-S type manifold base pplicable base Sub-plate SSY- 0 type SSY- type SSY- S type base.-

12 Series SY00 0 Type Manifold: Top orted/ssy-0- Station -F-Q Grommet (G), (H) (Station n) Station -ø. (Mounting holes) L G: 00 H: 00.8 (7.8) n-m X 0. ( port). Bracket M X 0.8 ( port) (itch) =0. G, H: 7. G, H : 8 Manual override ( Indicator light and surge voltage suppressor ) L plug connector (L) M plug connector (M) No bracket is assembled prior to delivery. Mount one to the appropriate position. (ttach two brackets if more than five stations.) 7.. Other dimensions are same as grommet style. Other dimensions are same as grommet style. Station L

13 Series SY00 Type Manifold: Top orted/ssy-- Station -Q Grommet (G), (H) (Station n) (Station ) SY SYJ VK G: 00 H: n-m X 0. ( port) Manual override.. (itch) = VZ V VG -M X 0.8 (/ port) G, H: 0. G, H : 0.8 -ø. (Mounting holes) L L ( Indicator light and surge voltage suppressor ) VQ VQZ L plug connector (L) M plug connector (M) Other dimensions are same as grommet style. Other dimensions are same as grommet style. Station L L

14 Series SY00 S Type Manifold: Side orted/ssy-s- Station -M/M-Q Grommet (G), (H) In case of M In case of M (Station n) (Station ) (Station n) (Station ) n-m X 0.8 (itch) n-m X 0. (itch) ( port) =0.. ( port) =0.. Manual override (itch) =0.. G: 00 H: M X 0.8 (/ port) G, H: 0. G, H : 0.8 -ø. (Mounting holes) L L L plug connector (L) M plug connector (M) Other dimensions are same as grommet style. Other dimensions are same as grommet style. Station L L

15 Series SY Made to Order (Contact SMC for further specifications, dimensions and delivery lead time.) Order Made Specifications Series Coil rated voltage (V) ower consumption (W) Inrush Holding Specifications except those mentioned above are same at standard. SY T SY T ower Saver ower consumption is decreased by / of standard product by reducing electrical power at holding. (This is effective when energizing time exceeds ms at rated voltage of V DC.) How to Order Body ported Base mounted SY SY ctuation Normally closed Nomally open Option Standard Large flow capacity style T T ated voltage V DC V DC L Z M Z, V DC M Enter in the same way as standard models. Operating principle ower consumption at holding is decreased with the below indicated circuit, for energy savings. efer to electrical power wave form shown below. Timer circuit Electrical circuit (with power saving circuit ) LED : Inrush current, : Holding current <Electrical wave form of power saving style, SY T> V 0V 0.W 0.W 0W Diode ms pplied voltage Coil Standard ower saver ed(+) Black(-) SY SYJ VK VZ V VG VQ VQZ <Electrical wave from of power saving style, SY T> pplied voltage V 0V 0.8W Large flow capacity 0.W 0W ms ower saver.-

16 .-

Series SYJ300/500/700

Series SYJ300/500/700 ort Solenoid Valve ubber Seal Series SYJ00/00/00 Low power consumption: 0.W (Without light) (Current draw: 1m at 4V DC) Completely interchangeable ilot exhaust with the previous series VJ00/00/00 and VZ00/00.

More information

3 Port Solenoid Valve

3 Port Solenoid Valve ubber Seal 3 ort Solenoid Valve Series SYJ300/00/700 SYJ VQZ V VG Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M1.7 to M. V3 Cover

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve V00 Series Rubber Seal Power consumption 0. W (with power saving circuit) Note) Refer to page 7 for details. temperature rises: C (with power saving circuit) Sonic conductance Series

More information

Specifications. Fluid Ambient and fluid temperature ( C)

Specifications. Fluid Ambient and fluid temperature ( C) Series 0-V00 Rubber seal port direct operated solenoid valve Specifications Fluid Ambient and fluid temperature ( C) Note ) Response time (DC) ms Max. operating frequency (Hz) Manual override Lubrication

More information

Series SYJ3000/5000/7000

Series SYJ3000/5000/7000 , ort Solenoid Valve ubber Seal Series SYJ000/000/7000 Low power consumption: 0.W(Without light) (Current draw: 1m at V DC) right color tone and state of the art design SY SYJ SX VK VZ VF VF V7 V Completely

More information

3 Port Solenoid Valve

3 Port Solenoid Valve 3 ort Solenoid Valve Series VKF300 ubber Seal Direct Operated oppet Type Compact yet provides a large flow capacity Body width 8 mm vailable in vacuum applications ( 0. ka) Can be used in vacuum/release

More information

Rubber seal 3 Port Pilot Solenoid Valve. Specifications. Fluid Operating pressure range MPa. Internal pilot

Rubber seal 3 Port Pilot Solenoid Valve. Specifications. Fluid Operating pressure range MPa. Internal pilot ubber seal ort ilot Solenoid Valve Series SYJ00 Specifications efer to www.smcworld.com for details of products compatible with overseas standards. Body ported Base mounted Fluid Operating pressure range

More information

2 position single 2 position double. 3 position Ambient and fluid temperature ( C) Note 1) 3 position Max. operating

2 position single 2 position double. 3 position Ambient and fluid temperature ( C) Note 1) 3 position Max. operating / ort Solenoid Valve ubber Seal Series SYJ000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Specifications JIS Symbol port port (manifold) position

More information

Series VQ Port Solenoid Valve

Series VQ Port Solenoid Valve Port Solenoid Valve Series VQ00 Outstandingly high speed, stable response, and long service life. ON:. ms, OFF: ms, Dispension accuracy ms (; supply pressure 0. MPa) 00 million cycles or more (Factors

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve Series VQ00 Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C 9080-0-Main Office: (0) 88-900-Outside Local rea: (800) 8-900-www.stevenengineering.com Outstandingly

More information

3 Port Solenoid Valve. Copper-free specifications. The fluid contacting section is copper-free and the standard style can be used as it is.

3 Port Solenoid Valve. Copper-free specifications. The fluid contacting section is copper-free and the standard style can be used as it is. Port Solenoid Valve Series VQ 00 Unprecedented high speed, stable response, and extra-long service life. ON:.ms, OFF: ms, Dispension accuracy ±ms (With indicator light and surge voltage suppressor; supply

More information

Body width of 10mm, Nl/min (49.08) 2W (Standard) Nl/min (78.52) 4W (U type: Large flow) Vacuum applications possible (up to 100kPa) 3 S.

Body width of 10mm, Nl/min (49.08) 2W (Standard) Nl/min (78.52) 4W (U type: Large flow) Vacuum applications possible (up to 100kPa) 3 S. High speed coil with stable response times ON: 4ms, OFF: 2ms, Dispersion accuracy: ±1ms (With light and surge voltage suppressor at a supply pressure of 0.5MPa, subject to clean, dry air) 4 Port Direct

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry ir VQ0/30 Series Compact and lightweight with large flow capacity [Option] VQ0 Weight (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 Series VCH VDW SX0

More information

Series SYJ Way 4 and 5 Port. Rubber Seal Solenoid Pilot Valve

Series SYJ Way 4 and 5 Port. Rubber Seal Solenoid Pilot Valve N Way and ort Series SYJ000 ubber Seal Solenoid ilot Valve ODUCTS Interchangeable with the NVJ Series Low ower Consumption: 0.W ase Mounted/ody orted Configurations Manifolds with uilt-in One-Touch Fittings

More information

Vacuum applications possible (up to 100kPa) Base mounted. Cylinder bore size (mm) Series CM2. Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 300mm

Vacuum applications possible (up to 100kPa) Base mounted. Cylinder bore size (mm) Series CM2. Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 300mm 4 Port Direct Operated Poppet Solenoid Valve Series D1000 High speed coil with stable response times ON: 4ms, OFF: 2ms, Dispersion accuracy: ±1ms (With light and surge voltage suppressor at a supply pressure

More information

4/5 Port Solenoid Valve

4/5 Port Solenoid Valve ubber Seal / ort Solenoid Valve Series 000 / 000 / 000 [Option] SJ SY SV SZ V S000 VQ VQ VQ VQC VQZ SQ VFS VF VQ Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread

More information

Example. U side. Stations SY5000

Example. U side. Stations SY5000 45 Type 5 ort Solenoid Valve ase Mounted Manifold Stacking Type/DIN ail Mounted/Individual Wiring Series SY3000/5000 How to Order Manifold How to Order Manifold ssembly (Example) SS5Y 3 45 05 U C6 Example

More information

Rubber Seal VP300/500/700

Rubber Seal VP300/500/700 Port Pilot Operated Poppet Rubber Seal 00/500/700 High flow capacity Cv1.0 (00), Cv. (500), Cv.0 (700) Low power consumption: 1.8W(DC) Possible to use as either selector valve or divider valve Changeable

More information

5 Port Solenoid Valve: Base Mounted Metal Seal/Rubber Seal. High speed & Long life. (Metal seal, with light and surge suppressor) 100 million cycles

5 Port Solenoid Valve: Base Mounted Metal Seal/Rubber Seal. High speed & Long life. (Metal seal, with light and surge suppressor) 100 million cycles ort Solenoid Valve: ase Mounted Metal Seal/Rubber Seal Series Space and capacity saving ilot valve is gathered at one side. Space saving design which does not have any protrusions. Space saving Capacity

More information

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions Port Solenoid Valve VT07 Series Direct Operated Poppet Type Power consumption 4 Standard wtype (Current product: 4.8 W) Energy-saving type.8 w (Current product: 2 W) Vacuum applications 0.2 kpa [Option]

More information

4/5 Port Solenoid Valve

4/5 Port Solenoid Valve CT.ES8 / ort Solenoid Valve Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M.7 to M2. 앬 Flow Characteristics Series Cover (stainless

More information

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry Plug-in nit Series 0 1 2 3 4 Series Type of actuation Metal Rubber 2 position single 3 position closed 3 position pressure Manifold Option How to Order Valves VQ 1 1 1 0 Y 5 LO Body type 1 0 1 Seal Metal

More information

Fluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single

Fluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single Valve Manifold Common Specifications Solenoid Valve Specifications Made to Order Specifications (For details, refer to page --08.) JIS Symbol position single solenoid position double solenoid position

More information

VQ1000. How to Order Manifold. Kit type

VQ1000. How to Order Manifold. Kit type - - ase Mounted VQ000/000 Manifold type D-sub connector ort Solenoid Valve Flat ribbon cable Connector Serial Directional Control Valves VQ000 How to Order, Manifold Options VQ000 How to Order, Manifold

More information

5 Port Solenoid Valve/Direct Poppet. Valve model VK3120. VK3120Y (Low wattage 2W DC) VK3140 VK3140Y (Low wattage 2W DC)

5 Port Solenoid Valve/Direct Poppet. Valve model VK3120. VK3120Y (Low wattage 2W DC) VK3140 VK3140Y (Low wattage 2W DC) Port Solenoid Valve/Direct Poppet Rubber seal Series VK3000 Nl/min 147 Compact/Width 18 X Length 8 (mm) Low power consumption 4W DC (Standard) 2W DC (Energy saver) Standard copper free specification All

More information

Series VP3145/3165/3185

Series VP3145/3165/3185 Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. N.C. N.C. X (P) N.O. N.O. X (P) Series VP 3 port Function plate makes it possible to

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body

More information

Power Consumption. 4/5 Port Solenoid Valve. Series SYJ3000/5000/7000. With Power Saving Circuit

Power Consumption. 4/5 Port Solenoid Valve. Series SYJ3000/5000/7000. With Power Saving Circuit CT.EUS8 UK ower Consumption / ort Solenoid Valve With ower Saving Circuit Series SYJ000/000/7000 Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced

More information

Series SV1000/2000/3000/4000

Series SV1000/2000/3000/4000 Valve/Sub-plate Type IP67 Compliant Series 000/000/000/000 How to Order C () () () () () () (E) (E) () (E) (E) () () (E) (E) () () (E) (E) () () (E) (E) Type of actuation position single position double

More information

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal Port Direct Operated Poppet Solenoid Valve, Rubber Seal Series 3000 or details about certified products conforming to international standards, visit us at www.smcworld.com. C: 0.4 dm 3 /(s bar) (Passage

More information

I N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications

I N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications I N D E VQ000 How to Order, Manifold Options VQ000 How to Order, Manifold Options VQ000/000 Model, Standard/Manifold Specifications VQ000/000 F (D-sub connector) VQ000/000 (Flat ribbon cable) VQ000/000

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body

More information

Cable Appendix. Valves. Cable Appendix. Page 16. Multi-way cables. D-sub Connector Cables. AXT100-DS Conforming to MIL-C-24308

Cable Appendix. Valves. Cable Appendix. Page 16. Multi-way cables. D-sub Connector Cables. AXT100-DS Conforming to MIL-C-24308 Cable ppendix Cable ppendix Multi-way cables The multi-pole connector cables used on SMC valves are common across several ranges. Cables are available in accordance with the MIL standard C-08 and also

More information

Series VQZ1000/2000/3000 Single Unit

Series VQZ1000/2000/3000 Single Unit +- ase Mounted lug Lead Unit ort Solenoid Valve Series VQZ// Single Unit [Option] How to Order Valve Made to Order (For details, refer to page 7.) VQZ Series VQZ body width mm VQZ body width mm VQZ body

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option. Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Body option Body

More information

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option 3 Port Solenoid Valve Direct Operated Poppet Type VT317 Series Rubber Seal [Option] Note) CE-compliant: Electrical entry is applicable only for the DIN terminal. Compact yet provides a large flow capacity

More information

4 Port Solenoid Valve

4 Port Solenoid Valve Port Solenoid Valve Rubber Seal Direct Operated Poppet Type Unprecedented high speed, with stable response times ON: ms, OFF: ms, Dispersion accuracy ±1 ms ( at a supply pressure of 0. MPa) (Use clean

More information

4 Port Solenoid Valve

4 Port Solenoid Valve Port Solenoid Valve Rubber Seal Direct Operated Poppet Type Unprecedented high speed, with stable response times ON: ms, OFF: ms, Dispersion accuracy ±1 ms ( at a supply pressure of 0. MPa) (Use clean

More information

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS Rubber Seal 3 Port Solenoid Valve Series VKF300 Direct Operated Poppet Type Compact yet provides a large flow capacity Body width 18 mm Various manifold piping directions Output port: Manifold set-up allowing

More information

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications Port Solenoid Valve Direct Operated Poppet Type 000 Series Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W

More information

3 Port Solenoid Valve Direct Operated Poppet Type

3 Port Solenoid Valve Direct Operated Poppet Type 3 Port Solenoid Valve Direct Operated Poppet Type VK300 Series Rubber Seal [Option] Universal porting Available for N.C. valve, N.O. valve, divider valve, selector valve, etc. C: 0.80 dm 3 /(s bar) (Passage

More information

5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted

5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted Metal Seal ort Solenoid Valve Series // Rubber Seal.. ower consumption:. W/. W Compact, High Flow Series Valve width (mm) (Standard) (High pressure type, High speed response type) ody ported ase mounted

More information

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option. 3 Port Solenoid Valve Direct Operated Poppet Type Series VT325 Rubber Seal [Option] Note) Applicable only for DIN terminal type. Compact yet provides a large flow capacity Dimensions (W x H x D) 55 x 118

More information

3 Port 3 Position Valve

3 Port 3 Position Valve Port Position Valve Pilot Solenoid ir Operated ohs Intermediate stopping of cylinders * up to ø15 is possible. Pilot solenoid Manifold ir operated * For VEX 4, 00 mm/s, horizontal movement Power consumption:

More information

SS5Y 3 05 U C6. Series SY3000/5000 Base Mounted Monifold Stacking Type/DIN Rail Mounted Individual Wiring

SS5Y 3 05 U C6. Series SY3000/5000 Base Mounted Monifold Stacking Type/DIN Rail Mounted Individual Wiring Type4 SY000/000 ase Mounted Monifold Stacking Type/DIN ail Mounted Individual Wiring How to Order Manifold SSY 4 0 U C6 How to Order Valve Manifold ssembly Ordering example SY000 SY000 Valve stations 02

More information

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000) 5 Port Pilot Operated Solenoid Valve Rubber Seal Series 1000/3000/5000 Large flow capacity Yet compact size. Low power consumption 1.8 W (DC) Exhausting equipment for pilot valve not required. Common exhaust

More information

3 Port Air Operated Valve. SYJA300 Series. How to Order. Nil Without sub-plate. Type of actuation. Normally closed Normally open

3 Port Air Operated Valve. SYJA300 Series. How to Order. Nil Without sub-plate. Type of actuation. Normally closed Normally open 3 ort ir Operated Valve SYJ300 Series How to Order SYJ3 M3 Bracket Nil Without bracket F With bracket *The bracket is not mounted. *The bracket cannot be retrofitted later. SYJ3 Type of actuation Normally

More information

Q1 Q2 Q3. 2 stage performance. 3 stage performance. Suction flow rate. 250% suction flow rate increase. Release flow rate adjusting needle.

Q1 Q2 Q3. 2 stage performance. 3 stage performance. Suction flow rate. 250% suction flow rate increase. Release flow rate adjusting needle. Multistage Ejector 112/212 Series Energy-saving, large flow rate, 3 stage diffuser construction Suction flow rate increased 25% and air consumption reduced 2% with 3 stage diffuser construction (ersus

More information

Compact Vacuum Ejector

Compact Vacuum Ejector Compact acuum Ejector Series ZA Total length Total width 7.9 mm 9.9 mm Total height. mm Response time 0 ms Response time for up to 0 ka Nozzle diameter: ø0.7 iping: ø/ø. x 0 mm Able to install on the moving

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve Metal Seal / Rubber Seal ower consumption:..w/..w ower consumption:. W/. W Compact, High Flow (Standard) (High pressure type, High speed response type) ody ported ase mounted Series

More information

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications Port Solenoid Valve Direct Operated Poppet Type Series 000 Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W

More information

ISO Standard Solenoid Valve. Series VQ7-6/7-8. (Size 1) (Size 2) Conforms to ISO Standard 5599/I

ISO Standard Solenoid Valve. Series VQ7-6/7-8. (Size 1) (Size 2) Conforms to ISO Standard 5599/I ISO Standard Solenoid Valve Series VQ7-6/7-8 (Size ) (Size ) Conforms to ISO Standard /I.0- Ideal for driving cylinders up to Large flow capacity ø00 (VQ7-6, Size ) ø60 (VQ7-8, Size ) Nl/min VQ7-6: 668.

More information

How to Order Valve. Body type. Symbol Body type B Base mounted with screws 10 S070 B 5 B G 10 S070 C 5 B G 32. Body type.

How to Order Valve. Body type. Symbol Body type B Base mounted with screws 10 S070 B 5 B G 10 S070 C 5 B G 32. Body type. Series -S00 ompact Direct Operated Port Solenoid Valve ontrol Valves ase mounted ody ported lean Series lean Series V S R oil voltage 24 VD VD VD VD VD Power consumption Pressure specification Flow rate

More information

3 Port Direct Operated Poppet Rubber Seal. Standard Continuous duty Energy saving Vacuum Energy saving/vacuum

3 Port Direct Operated Poppet Rubber Seal. Standard Continuous duty Energy saving Vacuum Energy saving/vacuum 3 Port Direct Operated Poppet Rubber Seal Series 307 Large Flow Capacity, yet Compact Size. Dimensions (W X H X D) 30 X 54.5 X 33 307 Nl/min 206.02 or more, 1/4 Low Power Consumption /VO307 4.8W DC/Standard

More information

13 msec (at 500 mm )/18.5 msec (at 1000 mm )

13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Vacuum / Release Unit Series VQD1000-V Rubber Seal Response speed 13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Distance from the unit to the work area [Option] Smooth detachment of a work piece without

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry Air Series VQ0/30 Compact and lightweight with large flow capacity VQ0 Mass (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 High frequency operation possible

More information

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4 Type of actuation 4 Piping 0 Side ported Bottom ported 4 Without sub-plate Large Size 5 Port Solenoid Valve Rubber Seal Series 50/4 70 Series VP 5 port solenoid valve 5 7 position single position double

More information

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry Series 0-VQ00 port solenoid valve How to Order Valves 0 VQ 0 F ir cylinder Clean series Series VQ Compact port valve Type of actuation Normally closed Note) Normally open Note) Normally open type is available

More information

Series SY3000/5000/7000

Series SY3000/5000/7000 Type20P 5 Port Solenoid Valve ody Ported Manifold ar Stock Type/Flat Ribbon Cable Series SY3000/5000/7000 How to Order Manifold How to Order Manifold ssembly (Example) SS5Y 5 20P 05 Manifold series 3 SY3000

More information

Vacuum / Release Unit

Vacuum / Release Unit Rubber Seal Vacuum / Release Unit Series VQD1000-V Response speed 13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Distance from the unit to the work area Smooth detachment of a work piece without over-blow

More information

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated. Power Valve: Regulator Valve Series Large capacity relief regulator Rapid tank internal pressure setting, air blow, constant pressure supply and driving, balance and driving, steps directional control

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal Seal ort Solenoid Valve Series VQ7-6/7-8 Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.6 VQ7-8/Manifold. Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and Size

More information

4/5 Port Air Operated Valve. SYJA3000 Series. How to Order. (Manifold use only) Type of actuation. 2 position single. 3 position closed center

4/5 Port Air Operated Valve. SYJA3000 Series. How to Order. (Manifold use only) Type of actuation. 2 position single. 3 position closed center 4/ ort ir Operated Valve SYJ000 Series How to Order ody ported SYJ M racket Nil Without bracket F With bracket *Refer to page 47 for the details of the brackets. ase mounted (4 port) SYJ 2 0 (Manifold

More information

Space Saving Vacuum Ejector/Vacuum Pump System

Space Saving Vacuum Ejector/Vacuum Pump System Space Saving acuum Ejector/acuum ump System Series Current 21.6 mm mm Width mm [Option] Weight 9 g Single unit with vacuum pressure switch and suction filter ZK2 ZR Z Z ZM ZL -X267 ZU Ejector.2 ump System.118

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve Series VQ7-6/7-8 Metal Seal Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.70 VQ7-8/Manifold.70 Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and

More information

5 Port Solenoid Valve

5 Port Solenoid Valve ort Solenoid Valve 7-6/7-8 Series Metal Seal Rubber Seal ISO Standard Size /Size 7-8/Single unit. Conforms to ISO standard /I Interface conforms to ISO standard Size (7-6) and Size (7-8). Outstanding high

More information

Base Mounted Series VQZ100/200/300. Nil. W Note) Compliant. Electrical entry. (DC speci- fication) terminal terminal. Coil voltage 24VDC

Base Mounted Series VQZ100/200/300. Nil. W Note) Compliant. Electrical entry. (DC speci- fication) terminal terminal. Coil voltage 24VDC Base Mounted Series VQZ00/00/00 VQZ00/00 / How to Order Valve Made to Order (For details, refer to page 9 and 4.) VQZ 5 5 M Series VQZ00 body width 5 mm VQZ00 body width 8 mm Type of actuation 4 N.C. N.O.

More information

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option Port Solenoid Valve Direct Operated Poppet ype Series V17 Rubber Seal [Option] Compact yet provides a large flow capacity Dimensions (W x H x D) 45 x 89.5 x 45 (Grommet) C:.6 dm /(s bar) (Passage ) Suitable

More information

Series VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non

Series VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non Table of Contents Series Port Pilot Operated Solenoid ValveRubber Seal... Series Variations... Manifold Variations... Precautions... Series 000 Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non

More information

Manifold Specifications

Manifold Specifications Series 00 Manifold Specifications Manifold Specifications Model Manifold type P(SUP)/R(EXH) Valve stations A port porting specifications Port size For internal pilot For external pilot Location Direction

More information

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve 5.0 Ma ilot Operated /3 ort Solenoid Valve & Check Valve Series VCH VCH4/4: ort VCH40: 3 ort VCHC40: Check Valve ilot Operated ort Solenoid Valve [Option] Series VCH40 Stable responsiveness Response time

More information

Terminal Block Box (Spring Type) SY3000/5000/7000 Series

Terminal Block Box (Spring Type) SY3000/5000/7000 Series INFORMATION 5 ort olenoid alve Terminal lock ox (pring Type) Y3000/5000/7000 eries Compact RoH Height 6.7 mm shorter (Approx. 9% reduction) Installation area of the terminal block box Reduced by approx.

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Rubber Seal Port Solenoid Valve Series Manifold Single Unit ase Mounted Manifold VV01 V100 ar base P.18 ody Ported P.10 ase Mounted P.10 VQD VKF VK VT VS Separable base ody Ported Manifold P.1 Stacking

More information

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector Series 0-SZ000 Port Solenoid Valve Cassette Type Manifold Series 0-SZ000 / Plug-in Type Model Manifold (P: SUP), / (R: EXH) Valve stations (With power terminal) pplicable connector Internal wiring (),

More information

Series SJ3A6. Vacuum Release Valve with Restrictor P.86 P.90. D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510

Series SJ3A6. Vacuum Release Valve with Restrictor P.86 P.90. D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510 Vacuum Release Valve with Restrictor Series SJ3A6 SJ Plug-in Type Connector Connection P.86 D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510 Non Plug-in Type Individual

More information

Series SY3000/5000 How to Order Manifold

Series SY3000/5000 How to Order Manifold Type N ort Solenoid Valve ase Mounted Manifold Stacking Type/DIN Rail Mounted/Connector ox SY/ How to Order Manifold SSY SY SY Specifications Symbol Specifications With connector box (COM spec.) N With

More information

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications For details about certified products conforming to international standards, visit us at www.smcworld.com. Series SQ000 Plug Lead Unit How to Order Manifold SSQ 0 FD D Electrical entry F kit D-sub Connector

More information

Series VP3145/3165/3185

Series VP3145/3165/3185 Large Size 3 Port Solenoid Valve Series VP345/365/385 Rubber Seal Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. Function plate makes

More information

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot 3 Port Solenoid Valve Pilot Operated Poppet Type Series VG342 Rubber Seal [Option] Low power consumption 4.8 W DC (Standard type) 2 W DC (Energy-saving type) No lubrication required Possible to use in

More information

Series SY3000/5000/7000

Series SY3000/5000/7000 Type1P Type2P 5 Port Solenoid Valve ase Mounted Manifold ar Stock Type/Flat Ribbon Cable Series /5000/000 How to Order Manifold Type 1P/Compact style SS5Y 5 1P 05 C8 Manifold series 3 5, port size Thread

More information

5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in. Standard Specifications. Fluid Operating pressure range

5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in. Standard Specifications. Fluid Operating pressure range For details about certified products conforming to international standards, visit us at www.smcworld.com. Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series VFR2 JIS Symbol type

More information

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated. Power Valve: Regulator Valve Series Large capacity relief regulator Rapid tank internal pressure setting, air blow, constant pressure supply and driving, balance and driving, steps directional control

More information

SYA3000/5000/7000. How to Order SYA3000 SYA5000. Bracket One-touch fitting for ø8 G 1 4 With foot bracket. F1 One-touch fitting for ø8 SYA7000 G 1 8

SYA3000/5000/7000. How to Order SYA3000 SYA5000. Bracket One-touch fitting for ø8 G 1 4 With foot bracket. F1 One-touch fitting for ø8 SYA7000 G 1 8 Port Air Operated Valve SYA000/000/7000 How to Order Symbol M C6 01F C6 02F C10 Without bracket A/B port size Port size Series M One-touch fitting for ø4 SYA000 One-touch fitting for ø6 G 1 8 One-touch

More information

3MA0/3MB0. Small pneumatic valve. 3 port direct acting valve CONTENTS. Space saving Valves are compactly designed with widths of 10 mm

3MA0/3MB0. Small pneumatic valve. 3 port direct acting valve CONTENTS. Space saving Valves are compactly designed with widths of 10 mm M0/MB0 Small pneumatic valve M Overview The M0 and MB0 Series port valve is a 0 mm wide miniature direct-acting poppet valve compatible with system downsizing. variety of types, including discrete and

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal seal Port Solenoid Valve Series VQ Rubber Seal Space-saving profile Clean space saving design with all pilot valves concentrated to one side with no protrusions in any direction Space-saving % less

More information

1 station. 3 Port Solenoid Valve. VV100 Series. Highly Integrated Unit Manifold

1 station. 3 Port Solenoid Valve. VV100 Series. Highly Integrated Unit Manifold Port Solenoid Valve VV00 Series Highly Integrated Unit Manifold po ted - pera irect-o d station es on rt valv ally ividu Ind wired n be ve ca val d. adde ector Con-inn connection) lug (For p ø connection

More information

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry Port Solenoid Valve Series 2-SY II 2G Ex ia IIC T4...T Gb Ta 10 C to 0 C 044 II 2G Ex ia IIC T6 Gb Ta 10 C to 4 C How to order 2 SY 1 2 0 01 F TEX category 2 7 9 Series 2-SY000 2-SY7000 2-SY9000 racket

More information

5 Port Solenoid Valve

5 Port Solenoid Valve 5 Port Solenoid Valve Series VFR//4/5/6 Rubber Seal Series Variations Series Sonic conductance C [dm /(s bar)] Type of actuation Voltage position single type Passage: 4/ 5/ (A/B EA/EB) Electrical entry

More information

Series SY3000/5000 Base Mounted Manifold Stacking Type/DIN Rail Mounted Connector Box 24V. D side D. Blanking plate assembly SX A

Series SY3000/5000 Base Mounted Manifold Stacking Type/DIN Rail Mounted Connector Box 24V. D side D. Blanking plate assembly SX A Type N SY/ ase ounted anifold Stacking Type/DIN Rail ounted Connector ox How to Order anifold SSY SY SY Specifications Symbol Specifications With connector box (CO spec.) N With connector box ( CO spec.)

More information

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry TEX Compliant Port Solenoid Valve Series 2-SY II 2G Ex ia IIC T4...T Gb Ta 10 C to 0 C 44 II 2G Ex ia IIC T6 Gb Ta 10 C to 4 C How to order 2 SY 1 2 0 01 F TEX category 2 7 9 Series 2-SY000 2-SY7000 2-SY9000

More information

5 Port Pilot Solenoid Valve Rubber Seal

5 Port Pilot Solenoid Valve Rubber Seal 5 Port Pilot Solenoid Valve Rubber Seal VF1000/3000/5000 Large flow capacity, Yet compact size. Low power consumption. 1.8WDC Exhausting equipment for pilot valve not required. Common exhaust for main

More information

(Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

(Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC 5 Port Pilot Operated Solenoid Valve Metal Seal Series VZS Series Variations Plug-in Type Base Mounted Type (With sub-plate) Non Plug-in Type Base Mounted Type (With sub-plate) Series Sonic conductance

More information

Plug Lead Unit: Flip Type

Plug Lead Unit: Flip Type Series ody orted lug Lead Unit: Flip Type For details about certified products conforming to international standards, visit us at www.smcworld.com. 0 Series Kit/Electrical entry/cable length F kit (D-sub

More information

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated. Power Valve: Regulator Valve Series 1 Large capacity relief regulator Rapid tank internal pressure setting, air blow, constant pressure supply and driving, balance and driving, steps directional control

More information

3, 5 port pilot operated valve Pneumatic valve / master valve. Discrete valve. Manifold

3, 5 port pilot operated valve Pneumatic valve / master valve. Discrete valve. Manifold K/K, pilot operated valve neumatic valve / master valve MNE0 MNE0 M MN W WG MNS0 MNS0 T L-/ S/0 S/ K/ F CONTENTS Safety precautions 776 Discrete valve ody ing (K/K to ) 868 Sub-plate ing (K to ) 87 Manifold

More information

10 mm. 7.5 mm. 40 mm. 4 Port Solenoid Valve. Series SJ2000/3000 SJ3000 SJ2000. Cassette Type Manifold. Connecter connection

10 mm. 7.5 mm. 40 mm. 4 Port Solenoid Valve. Series SJ2000/3000 SJ3000 SJ2000. Cassette Type Manifold. Connecter connection Rubber Seal Port Solenoid Valve Series SJ000/000 Cassette Type Manifold 0 mm 7. mm (SJ000) 0 mm (SJ000) Non plug-in type Individual wiring manifold SJ000 SJ000 Can be mounted together. Connecter connection

More information

S Y 3 A F NFZD

S Y 3 A F NFZD SY3000 IFM Serie SY HOW TO ORDER - VALVES S Y 3 A 0 0 5 F NFZD Series 3 SY3000 Type of actuation Manual override D: Push-turn locking type A Rated voltage 5 24VDC SPECIFICATION Fluid Air Operating pressure

More information

SOLENOID VALVES, SERIES

SOLENOID VALVES, SERIES VALVES GENERAL CATALOG SOLENOID VALVES, SERIES INDEX Features 365 Basic Models and Configuration 366 Solenoid Valve Order Codes 367 Manifold Order Codes 368 112 Series Specifications 369 Operating Principles

More information

D-sub Connector. Cassette base manifold SV1000/SV2000 Tie-rod base manifold SV1000/SV2000/SV3000/SV4000

D-sub Connector. Cassette base manifold SV1000/SV2000 Tie-rod base manifold SV1000/SV2000/SV3000/SV4000 D-sub Connector J Tie-rod base Cassette base pplicable series Cassette base manifold 000/000 Tie-rod base manifold 000/000//000 Number of connectors: pins MIL-C-08 Conforming to JIS-X-0 --6 For details

More information

SOLENOID VALVES VALVES GENERAL CATALOG SERIES INDEX

SOLENOID VALVES VALVES GENERAL CATALOG SERIES INDEX resenting our CD drawing data catalog VVES GENE CTOG SOENOID VVES SEIES INDEX Characteristics Basic Models and Configuration 1 andling Instructions and recautions Specifications Solenoid Valve Order Code

More information