Size: px
Start display at page:

Download "KDL/EMV cable entry system"

Transcription

1 KDL/EMV cable entry system 43

2 KDL/EMV cable entry system Advantages Discharge sheath currents The KDL-EMV is a cable entry system made of plastic with a metallized surface. This plate can be used as a troublefree way to discharge sheath currents from electromagnetic cable shielding. The KDT/Z-EMV cable entry grommet uses a fitted metal braiding to achieve the connection between the cable shielding and the cable entry system. An alternative opportunity to discharge sheath currents comes through an additional discharge plate that can mounted onto the existing drilling pattern. Easy assembly Large cut-out Variable No additional parts required No extra mounting effort required 44

3 Overview Page 48 Page 49 Page 50 Cable entry system Type KDL16/x-EMV KDL metallized for cut-outs for 16-pole connectors e.g. Harting or Wieland. Cable entry system Type KDL24/x-EMV KDL metallized for cut-outs for 24-pole connectors e.g. Harting or Wieland. Cable entry system Type KDL 2/10-EMV Cable entry system metallized for 10 cable entry grommets. Page 51 Cable entry grommet Type KDT/Z-EMV KDT with metal mesh insert for cable insertion with simultaneous discharge of sheath currents. 45

4 KDL/EMV cable entry system Selection table Cable entry grommets Type KDT/Z-EMV Cable diameter inch (3-16 mm) Cable diameter inch (16-29 mm) Cable entry system Order no. Opening, small Opening, large KDL 16/2-EMV KDL 16/4-EMV KDL 24/3-EMV KDL 24/5-EMV KDL 2/10-EMV

5 Material data Type Material Min. Temperature Max. Fire classification UL 94 RoHS Compliant Halogen-free Phosphorous-free Cadmium-free Asbestos-free Lead-free Silicone-free KDL 16/x-EMV Polyamide with conductive coating -40 F 257 F VO KDL 24/x-EMV Polyamide with conductive coating -40 F 257 F VO KDL 2/10-EMV Polyamide with conductive coating -40 F 257 F VO KDT/Z-EMV Thermoplastic rubber with conductive textile tape -40 F 176 F HB ** = not certified 47

6 KDL/EMV cable entry system Cable entry system, type KDL 16/x-EMV -40 to 257 F Polyamide with conductive coating V0 The cable entry system KDL/EMV is based on the cable entry system KDL. A conductive surface allows cable sheath interference to be discharged onto the control cabinet simply and without additional aids. Field-related interferences are discharged by the metallization. Suitable for standard cut-out 16-pole connectors from Harting or Wieland, for example (51.5) 2.03 (51.5) 2.28 (58) 0.63 (16) 0.63 (16) Ø 0.22 (5.5) 1.42 (36) 4.57 (116) 3.39 (86) KDL EMV Type Order no. Color No. of openings Installation height Pack small / large inch qty KDL 16/2-EMV chrome - / KDL 16/4-EMV chrome 4 / Replacement parts: Replacement seal KDL16-EMV Matching grommets KDT/Z-EMV; ATG-EMV; BTK 17; BTG 32 Matching label plate (See ACS catalogue): Type KSS 20 x 9 or KSS 10 x 8 The right tool for cut-out production can be found in the chapter «Punching tools» 48

7 Cable entry system, type KDL 24/x-EMV -40 to 257 F Polyamide with conductive coating V0 The cable entry system KDL/EMV is based on the cable entry system KDL. A conductive surface allows cable sheath interference to be discharged onto the control cabinet simply and without additional aids. Field-related interferences are discharged by the metallization. Suitable for standard cut-out 24-pole connectors from Harting or Wieland, for example (65) 2.56 (65) 2.28 (58) 0.63 (16) 0.63 (16) Ø 0.22 (5.5) 1.42 (36) 5.75 (146) 4.41 (112) KDL EMV Type Order no. Color No. of openings Installation height Pack small / large inch qty KDL 24/3-EMV chrome 1 / KDL 24/5-EMV chrome 5 / Replacement parts: Replacement seal KDL24-EMV Matching grommets KDT/Z-EMV; ATG-EMV; BTK 17; BTG 32 Matching label plate (See ACS catalogue): Type KSS 20 x 9 or KSS 10 x 8 The right tool for cut-out production can be found in the chapter «Punching tools» 49

8 KDL/EMV cable entry system Cable entry system, type KDL 2/10-EMV -40 to 257 F Polyamide with conductive coating V0 The cable entry system KDL/EMV is based on the cable entry system KDL. A conductive surface allows cable sheath interference to be discharged onto the control cabinet simply and without additional aids. Field-related interferences are discharged by the metallization. Larger cut-outs can be used to pass through up to 10 wires with large plugs (65) 2.56 (65) 3.54 (90) 1.28 (32.5) 1.28 (32.5) Ø 0.22 (5.5) 2.17 (55) 5.75 (146) 4.41 (112) KDL 2/10-EMV Type Order no. Color No. of openings Installation height Pack small / large inch qty KDL 2/10-EMV chrome 10 / Replacement parts: Replacement seal Matching grommets: KDT/Z-EMV; BTK17 Matching label plate (See ACS catalogue): Type KSS 20 x 9 or KSS 10 x 8 The right tool for cut-out production can be found in the chapter «Punching tools» 50

9 Cable entry grommets, type KDT/Z-EMV -40 to 176 F Thermoplastic rubber with conductive textile tape HB The cable entry grommet KDT/Z-EMV is a grommet adapted to the sheath diameter with a conductive textile tape to discharge interferences to the control cabinet. Strain relief can be provided quickly and easily for cables from a diameter of 0.39 inch using cable ties. KDT/Z-EMV... Type Order no. Color for sheath of Ø for opening No. Pack inch small / large Openings qty Grommet, small KDT/Z-EMV black l / KDT/Z-EMV black l / KDT/Z-EMV black l / KDT/Z-EMV black l / KDT/Z-EMV black l / KDT/Z-EMV black l / KDT/Z-EMV black l / KDT/Z-EMV black l / KDT/Z-EMV black l / KDT/Z-EMV black l / KDT/Z-EMV black l / KDT/Z-EMV black l / KDT/Z-EMV black l / Grommet, large KDT/Z-EMV black / l 1 10 KDT/Z-EMV black / l 1 10 KDT/Z-EMV black / l 1 10 KDT/Z-EMV black / l 1 10 KDT/Z-EMV black / l 1 10 KDT/Z-EMV black / l 1 10 KDT/Z-EMV black / l 1 10 KDT/Z-EMV black / l 1 10 KDT/Z-EMV black / l 1 10 KDT/Z-EMV black / l 1 10 KDT/Z-EMV black / l 1 10 KDT/Z-EMV black / l 1 10 KDT/Z-EMV black / l

10 KDL/EMV cable entry system Cable entry grommets, type KDT/Z-EMV Type Order no. Color for sheath of Ø for opening No. Pack inch small / large Openings qty Adapter grommet ATG-EMV (adapter grommet) black - / l 1 10 Grommets match: KDL 16/xx-EMV; KDL 24/xx-EMV; KDL 2/10-EMV 52

11 Assembly Strip wire at the insertion point and lay into grommet (suitable for diameter at the shielding braid). Use cable ties for strain relief where necessary (from 0.39 inch diameter). Where required, install small sleeves into the adapter grommet. Insert grommet completely. Fill in empty spaces with dummy grommets. Join upper and lower part of frame. Fasten with the side screws. KSS 4x Position housing on cut-out and fasten. Ensure good contact between rail and control cabinet panel. 53

12 54

KDL cable entry system

KDL cable entry system 23 Advantages Assembling high-tech plugs securely in the control cabinet No need to keep cutting the plug off your cable! It is so easy to introduce preassembled plugs into the control cabinet. Cables

More information

KDL/E cable entry system

KDL/E cable entry system KDL/E cable entry system 13 KDL / E cable entry system dvantages We go at everything head first Even faster and simpler assembly of pre-fabricated conduits. The KDL/E replaces the well established KDL/N

More information

Industrial Automation Supply -- Tel: Cable entry plate KDP plastic round

Industrial Automation Supply  -- Tel: Cable entry plate KDP plastic round Cable entry plate KDP plastic round 79 Cable entry plate KDP plastic round Advantages Straight in! Now also for round cut-outs Install electric cable and pneumatic hoses with minimal effort, saving time

More information

Accessories product range

Accessories product range Accessories 199 Accessories product range Type SB/SBF (spiral tape) Spiral tapes are used to bundle cable harnesses efficiently and simply. The spiral tapes also protect the insulation of the wires. Page

More information

Cable protection conduit Murrflex closed

Cable protection conduit Murrflex closed Cable protection conduit Murrflex closed Type -4 to 266 F transient 32 F Mod. polypropylene V2 Self-extinguishing > 4. lb f /inch Suitable fittings: m-top, -tec, -fix, -jumbo, KFW, AT Self-extinguishing

More information

Type EW-PA / EWX-PA (high corrugation)

Type EW-PA / EWX-PA (high corrugation) Type / (high corrugation) -40 to 140 F transient 160 F Mod. polyamide 6 HB : > 40.00 lb f /inch : > 74.30 lb f /inch Suitable fittings: m-top, -tec, -fix, -jumbo, KFW, AT Most universal UR and CSA-listed

More information

Cable protection conduit holders

Cable protection conduit holders 161 Advantages Holder systems The various holder systems are manufactured from high-grade polyamide and polycarbonate. The new HS family offers the facility to arrange holders in rows as well as stacking

More information

Type EF (rectangular conduit)

Type EF (rectangular conduit) Type (rectangular conduit) -58 to 32 F transient 356 F Thermoplastic elastomer HB > 17.15 lb f /inch Suitable fittings: /B Rectangular cable protection conduit for medium mechanical stresses and maximum

More information

Type EW-PA-UL / EWX-PA-UL (high corrugation)

Type EW-PA-UL / EWX-PA-UL (high corrugation) Type / (high corrugation) -40 to 284 F transient 320 F Mod. polyamide 6 V0 Self-extinguishing : > 74.30 lb f /inch : > 3.800 lb f /inch Suitable fittings: m-top, -tec, -fix, -jumbo, KFW, AT Self-extinguishing

More information

FTG10OM1-0,6/1KV. 50 N/mm 2 of copper section max for fixed layings

FTG10OM1-0,6/1KV. 50 N/mm 2 of copper section max for fixed layings HEPR insulated flexible with braided shield of red copper wires and plastic sheath of halogen-free flame retardant and without emission of corrosive gases. The keeps the electrical characteristics for

More information

06. har-mik INTERFACE CONNECTORS

06. har-mik INTERFACE CONNECTORS . INTERFACE CONNECTORS Miniature D connectors are a must in various cableto-board applications where space saving and high data transfer rates are required. For the purposes of miniaturization and speed,

More information

PCS 100 SYSTEM INSTALLATION INSTRUCTIONS

PCS 100 SYSTEM INSTALLATION INSTRUCTIONS PCS 00 SYSTEM INSTALLATION INSTRUCTIONS PCS - 00 + - POWER 4VDC CW TIME LO NL 4 5 6 ON C&K SDA06 CCW HI RL WHITE BROWN BLACK NC L NC L ON C&K SDA04 4 NO M NO M RESET START 5V 4V COM (0) BLUE SCU-00 Made

More information

MultiLine MP 44. System overview. 1 Chain bracket. 2 Shelving system. Chain bracket angle. Separator TR. Chain bracket U-part

MultiLine MP 44. System overview. 1 Chain bracket. 2 Shelving system. Chain bracket angle. Separator TR. Chain bracket U-part MultiLine MP 44 System overview 1 Chain bracket 2 Shelving system Chain bracket angle Separator TR Chain bracket U-part 2 1 122 Guide channels Technical data Aluminium VAW Stainless steel VAW-E Loading

More information

Gecko Connectors Introduction

Gecko Connectors Introduction Gecko ontents Introduction Screw-Lok mm pitch High-Reliability onnectors Specifications Mating Profiles Female P onnectors Female able onnectors Male P onnectors Male able onnectors Latched mm pitch High-Reliability

More information

Flame-retardant PVC offers the protection you need.

Flame-retardant PVC offers the protection you need. Solid wall wiring duct Flame-retardant PVC offers the protection you need. Solid wall duct PVC Engineered to restrict wire access Constructed of flame-retardant PVC Improved flush sidewall and cover style

More information

Cable drag chain systems MP 3000

Cable drag chain systems MP 3000 Cable drag chain systems MP 3000 1 MULTILINE MP 3000 OPEN LOW-COST VARIANT CHAIN BRACKET WITH INTEGRATED STRAIN RELIEF TECHNICAL DATA Loading side Inside bend Available radii 50.0 300.0 Available interior

More information

Connect - Contact - Control. Circular Audio Miniature Connectors Series NF07 Series NF10 12,5 Ø max. max. cable diameter.

Connect - Contact - Control. Circular Audio Miniature Connectors Series NF07 Series NF10 12,5 Ø max. max. cable diameter. Connect - Contact - Control Ø Ø6 Ø9 Circular Audio Miniature Connectors Series NF07 Series NF0,5 Ø3. max. cable diameter 39.5 max. 4.5 A 58 e Connectors for audio technology: Series NF07 and NF0 Our well-proven

More information

Variety at OBO. Overview of junction boxes

Variety at OBO. Overview of junction boxes ariety at OBO Overview of junction boxes ariety OBO junction boxes Large or small, classic or modern, for standard or special applications variety is at home in the field of OBO junction boxes. There s

More information

20A & 30A IEC 309 Watertight pin & sleeve devices

20A & 30A IEC 309 Watertight pin & sleeve devices AH430R7W AH430C7W IP69K certified AH430P7W Product Description - North American 20A & 30A; 2-pole, 3-wire grounding; 3-pole, 4-wire grounding; 4-pole, 5-wire grounding Pin & sleeve plugs features & benefits

More information

Number of PG holes. 1 x PG 9 (Ø 15.5) 12 x PG 13.5 (Ø 21) 1 x PG 9 (Ø 15.5) /300/400/ Rittal Catalogue 32/Industrial Enclosures

Number of PG holes. 1 x PG 9 (Ø 15.5) 12 x PG 13.5 (Ø 21) 1 x PG 9 (Ø 15.5) /300/400/ Rittal Catalogue 32/Industrial Enclosures us enclosures G. us enclosures Enclosure:.38 Door:.5 IP 65 to EN 60 59/09.00, complies with NEMA. Door with l/h hinge, cam lock with double-bit insert, () support rail(s) S 35/7.5 (for G 586.). Drilled

More information

Company Switch Installation Instructions and User Manual

Company Switch Installation Instructions and User Manual Lex Products Corporation 15 Progress Drive Shelton, CT 06484 203.363.3738 203.363.3742 Fax Lex West 11847 Sheldon Street Sun Valley, CA 91352 818.768.4474 818.768.4040 Fax www.lexproducts.com info@lexproducts.com

More information

Installation Instructions (Translation) Marking. Description. Danger, warning and note symbols. Technical data. ANTARES ExtSet.

Installation Instructions (Translation) Marking. Description. Danger, warning and note symbols. Technical data. ANTARES ExtSet. Description Marking The ANTARES ExtSet makes it possible to distribute the Remote I/O ANTARES modules of an explosion-protected Remote I/O system ANTARES among a maximum of 4 metal mounting rails. For

More information

Power Connection Kit Installation Instructions. Terminator ZP-M for use with TEK and HTEK series constant watt heating cables

Power Connection Kit Installation Instructions. Terminator ZP-M for use with TEK and HTEK series constant watt heating cables Power Connection Kit Installation Instructions Terminator ZP-M for use with TEK and HTEK series constant watt heating cables For Power Connection (1 Cable), In-Line Splice Connection, or End Termination

More information

Push-in RTD Temperature Probe with Connecting Cable

Push-in RTD Temperature Probe with Connecting Cable Data Sheet 902150 Page 1/6 Push-in RTD Temperature Probe with Connecting Cable Temperature range from -50 to +400 C As single or double RTD temperature probe In 2-wire, 3-wire or 4-wire-circuit Connecting

More information

Strain relief / cable fixing plate

Strain relief / cable fixing plate Strain relief / cable fixing plate 175 Strain relief Strain relief, type ZL-fix The strain relief ZL-fi x may be used wherever cables, hoses, cords, wires or conduits must be relieved or routed in a way

More information

16A & 32A IEC 309 Watertight pin & sleeve devices

16A & 32A IEC 309 Watertight pin & sleeve devices Technical Data IEC 309 Product Description - International ; 2-pole, 3-wire grounding; 3-pole, 4-wire grounding; 4-pole, 5-wire grounding AH416R6W AH416C6W AH416P6W Pin & sleeve plugs features & benefits

More information

Cable drag chain systems MP 32

Cable drag chain systems MP 32 Cable drag chain systems MP 32 1 MP 32 OPEN PLASTIC OR ALUMINIUM VERSION FLEXIBLE CHAIN BRACKET BROAD INTERIOR LAYOUT TECHNICAL DATA Loading side Inside and outside bend MP CLASSIC Available radii 80.0

More information

Data sheet C6 A modul 24 port 180 M 1RU stainless steel

Data sheet C6 A modul 24 port 180 M 1RU stainless steel Illustrations Dimensional drawing Page 1/7 See enlarged drawings at the end of document Product specification 19 inch 1RU stainless steel module frame with 24 individual modules C6modul 180 certified to

More information

Distribution boxes with suspension hook

Distribution boxes with suspension hook Distribution boxes with suspension hook Distribution boxes with suspension hook Pegasus Page 258 Dimensions: HxWxD = 220x140x140mm Imst Page 260 Dimensions: HxWxD = 197x197x120mm Freistadt Page 262 Kombi

More information

Selection BASIC LINE BASIC LINEPLUS VARIO LINE SERIES TUBE

Selection BASIC LINE BASIC LINEPLUS VARIO LINE SERIES TUBE PLUS 324 System able carriers for movements PLUS For three-dimensional movements an be deployed on robots for swiveling and rotational movements: The same system for robot feet and arms With channel system,

More information

The patented rubber modules guarantee a quick and easily modifiable solution for routing and retrofitting cables.

The patented rubber modules guarantee a quick and easily modifiable solution for routing and retrofitting cables. Main Catalog VARIOZELL is the innovative producer of Cable entry and Strain-relief systems. Because the system allows you to modify the composition of the rubber modules to meet the needs of the immediate

More information

EPIC. Connector Accessories CONNECTOR ACCESSORIES. Glands, Seal Rings & Adapters Glands 412 EPIC SM & SP Glands, EPIC CM-M Glands

EPIC. Connector Accessories CONNECTOR ACCESSORIES. Glands, Seal Rings & Adapters Glands 412 EPIC SM & SP Glands, EPIC CM-M Glands CONNECTOR ACCESSORIES Glands, Seal Rings & Adapters Glands 412 EPIC SM & SP Glands, EPIC CM-M Glands D Series Pressure Screws 413 U Series Washers 413 Sealing Rings 413 Neoprene & Viton Concentric Sealing

More information

19" chassis F. Downloads and further important information can be found on the Internet under Overview Cabinets...

19 chassis F. Downloads and further important information can be found on the Internet under   Overview Cabinets... Overview... 0 Cabinets... 1 19" chassis Wall mounted cases... 2 Accessories for cabinets and wall mounted cases... 3 Climate control... 4 Desk-top cases... 5 02192001 Subracks/ 19" chassis... 6 ront panels,

More information

RoHS 2011/65/EU ISO 9001 ISO BS OHSAS 18001:2007 GREEN ELECTRONICS MSM. Terminal Blocks

RoHS 2011/65/EU ISO 9001 ISO BS OHSAS 18001:2007 GREEN ELECTRONICS MSM. Terminal Blocks RoHS 2011/65/EU e3 GREEN ELECTRONICS ISO 9001 ISO 14001 BS OHSAS 18001:2007 MSM Terminal Blocks Functional characteristics Dimensional class: medium RoHS 2011/65/EU Standard colour: green Height: 15.2

More information

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

RX 3 MCB 4500 A Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 RX 3 MCB 4500 A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

VD0C06N908C July 1998 Raleigh, NC, USA. Instruction Bulletin ALTIVAR 66, ALTIVAR 58, ALTIVAR 18. Dynamic Braking Resistor Kit User s Manual

VD0C06N908C July 1998 Raleigh, NC, USA. Instruction Bulletin ALTIVAR 66, ALTIVAR 58, ALTIVAR 18. Dynamic Braking Resistor Kit User s Manual Instruction Bulletin VD0C06N908C July 1998 Raleigh, NC, USA ALTIVAR 66, ALTIVAR 58, ALTIVAR 18 Dynamic Braking Resistor Kit User s Manual DANGER HAZARDOUS VOLTAGE Read and understand this bulletin in its

More information

Overview of junction boxes

Overview of junction boxes Overview of junction boxes ariety Staying young A series Classic and still youthful: The wellknown junction boxes of the A series have had a makeover. Halogen-free thermoplastic is just as much of a hallmark

More information

Club Car 1510 to Curtis 1268 Conversion

Club Car 1510 to Curtis 1268 Conversion Club Car 1510 to Curtis 1268 Conversion Installation Instructions 62-12685501CKI Rev. 05 7/18/14 Page 1 of 7 1510 to Curtis 1268 Conversion Installation Instructions Before you start turn Tow/Run switch

More information

ACS580, ACH580 and ACQ580 drive module frames R3 and R5 to R9 for cabinet installation (options +P940 and +P944) Supplement

ACS580, ACH580 and ACQ580 drive module frames R3 and R5 to R9 for cabinet installation (options +P940 and +P944) Supplement ABB GENERAL DRIVES, ABB DRIVES FOR HVAC, ABB DRIVES FOR WATER ACS580, ACH580 and ACQ580 drive module frames R3 and R5 to R9 for cabinet installation (options +P940 and +P944) Supplement Supplement ACS580,

More information

Data sheet C6 A RJ45 field plug pro

Data sheet C6 A RJ45 field plug pro Illustrations Dimensional drawing Page 1/6 See enlarged drawings at the end of document Product specification Cat.6 A class E A RJ45 plug to be assembled in the field fully shielded and multi-port capable

More information

Data sheet. E-DAT Industry RJ45 field plug PROFINET. Illustrations P/N PI EAN Product specification. Page 1/

Data sheet. E-DAT Industry RJ45 field plug PROFINET. Illustrations P/N PI EAN Product specification. Page 1/ Page 1/7 Illustrations Dimensional drawing Wiring See enlarged drawings at the end of document Product specification multi-port Cat.5 plug to be assembled in the field 100 MBit suitable according to IEEE

More information

Power Connection Kit Installation Instructions. Terminator DP-M for use with TEK and HTEK series constant watt heating cables

Power Connection Kit Installation Instructions. Terminator DP-M for use with TEK and HTEK series constant watt heating cables Power Connection Kit Installation Instructions Terminator DP-M for use with TEK and HTEK series constant watt heating cables For Power Connection (1 Cable), In-Line Splice Connection, or End Termination

More information

Directory chapter 08. InduCom Robust and EMI protected D-Sub interfaces

Directory chapter 08. InduCom Robust and EMI protected D-Sub interfaces Directory chapter 08 Robust and EMI protected D-Sub interfaces New Page General information.............................................. 08.02 Mounting details................................................

More information

partial statement 106 TITUS www.efb-elektronik.de 19 Networking cabinet TITUS S (Standard)... 108-109 19 Networking cabinet TITUS E (Enhanced)...110-111 19 Networking cabinet TITUS V (pre-assembled)...

More information

Series 3 & 4 Stainless Steel - Accessories

Series 3 & 4 Stainless Steel - Accessories - Accessories Splice Plates Standard 8-hole pattern for all steel splice plates. One pair including hardware provided with straight section. (Expansion splice quantity subtracted) Boxed in pairs with hardware.

More information

Setting New Standards. Widest Sealing Range Maximum Strain Relief Superior Protection Rating. 94 CONTA-CLIP, Inc. (732)

Setting New Standards. Widest Sealing Range Maximum Strain Relief Superior Protection Rating. 94 CONTA-CLIP, Inc. (732) Setting New Standards Widest Sealing Range Maximum Strain Relief Superior Protection Rating 94 CONTA-CLIP, Inc. (732) 564-0705 The principle benefits gland body Materials: Nickel plated brass Stainless

More information

Data sheet. E-DAT modul Cat.6A 8(8) jack, T568A. Illustrations P/N I EAN Product specification. Page 1/

Data sheet. E-DAT modul Cat.6A 8(8) jack, T568A. Illustrations P/N I EAN Product specification. Page 1/ Page 1/9 Illustrations Dimensional drawing Cut-out See enlarged drawings at the end of document Product specification modular termination unit Cat.6A, RJ45 component testing for Cat.6A to ISO/IEC 11801

More information

MultiLine MP 35. System overview. 1 Chain bracket. 2 Shelving system. Chain bracket angle. Separator TR. Chain bracket U-part. H-shaped shelf unit RE

MultiLine MP 35. System overview. 1 Chain bracket. 2 Shelving system. Chain bracket angle. Separator TR. Chain bracket U-part. H-shaped shelf unit RE System overview 1 Chain bracket 2 Shelving system Chain bracket angle Separator TR Chain bracket U-part H-shaped shelf unit RE 2 1 96 Guide channels Technical data Aluminium VAW Stainless steel VAW-E Loading

More information

Fiber Connector Shelf (CCS)

Fiber Connector Shelf (CCS) Corning Cable Systems Standard Recommended Procedure (SRP) 003-595 Issue 3, May 2007 Page 1 of 6 Fiber Connector Shelf (CCS) Table of Contents 1. General... 1 2. Precautions... 1 3. Components... 2 4.

More information

talon T3 DATA SHEET HOLD THE CABLES. HUG THE RUNG. Talon Products, LLC Conrad Anderson Hammond, Louisiana USA

talon T3 DATA SHEET HOLD THE CABLES. HUG THE RUNG. Talon Products, LLC Conrad Anderson Hammond, Louisiana USA Talon Products, LLC 47037 Conrad Anderson Hammond, Louisiana 70401 USA web: HugTheRung.com email: info1@hugtherung.com phone: +1 985 956 7600 Typical Installation in Cable Tray Talon cable cleats utilize

More information

Level indicators, screw plugs

Level indicators, screw plugs Level indicators, screw plugs 885 Product overview Level indicators, screw plugs Oil level gauges K0443 Plastic plugs K0452 Oil level gauges K0444 Page 888 Aluminium plugs K0453 Page 894 Oil level sight

More information

TO ALL OUR CUSTOMERS. Poles

TO ALL OUR CUSTOMERS. Poles Page 1 TO ALL OUR CUSTOMERS 1. NEWS: NEW 20-32-40A THERMOPLASTIC ENCLOSURES FOR THE ISOLATORS SERIES The thermoplastic ISOLATORS series offer has been expanded, introducing a range of products for 20,

More information

D-Sub adapter Cable entry protection with metric cable entries Cable entry protection with Pg cable entries

D-Sub adapter Cable entry protection with metric cable entries Cable entry protection with Pg cable entries Contents Page D-Sub adapter... 40.02 Han Split Hood... 40.04 Cable entry protection with metric cable entries... 40.06 Cable entry protection with Pg cable entries... 40.08 Coding for Hoods/Housings and

More information

Directory chapter 01

Directory chapter 01 Directory chapter 01 Miniature D connectors, 1.27 mm pitch Page I/O connectors................................................. 01.02 Pin and socket Technical characteristics........................................

More information

Terminator DL-S for use with BSX *, HTSX, KSX self-regulating, HPT power-limiting, and FP constant watt heating cables

Terminator DL-S for use with BSX *, HTSX, KSX self-regulating, HPT power-limiting, and FP constant watt heating cables Lighted Power Connection / Lighted End Termination Kit Installation Instructions Terminator DL-L for use with RSX, TSX, VSX self-regulating heating cables Terminator DL-S for use with BSX *, HTSX, KSX

More information

Luminus Series Amphenol Pcd

Luminus Series Amphenol Pcd Luminus Series Amphenol Pcd Amphenol Pcd Pcd is is one one of of the the world s leading suppliers of of interconnect products for for Military, Commercial Aerospace and and Industrial applications. Located

More information

FireBox T series The evolution of electrical function maintenance

FireBox T series The evolution of electrical function maintenance FireBox T series The evolution electrical function maintenance THINK CONNECTED. Basic principles and meaning electrical function maintenance Function Function maintenance for electrical systems Electrical

More information

ATEX/IECEx RTD temperature probe

ATEX/IECEx RTD temperature probe Page 1/8 ATEX/IECEx RTD temperature probe with connecting cable acc. to DIN EN 60751 For temperatures from -100 to +600 C As single, double, or triple RTD temperature probe In two-wire, three-wire, or

More information

Rittal CM Compact System Enclosures

Rittal CM Compact System Enclosures Rittal CM Compact System Enclosures Compact class = Top class: Infinite possibilities R Compact enclosure on the outside, Top enclosure on the inside! Index Convincing details... 3 5 Compact system enclosures

More information

Cable drag chain systems MP 35

Cable drag chain systems MP 35 Cable drag chain systems MP 35 1 MULTILINE MP 35 OPEN METAL CHAIN BRACKET LOW-COST VARIANT TECHNICAL DATA Loading side Inside bend Available radii 70.0 300.0 Available interior widths With plastic frame

More information

Installation instructions

Installation instructions Service Installation instructions Audi A4/A5 (B8 series) 2008 Engine sound system For scope of delivery 8T0.071.901* Audi Genuine Accessories Service Department. Technical Information Service Contents

More information

MODEL 8682 SUREFLOW ADAPTIVE OFFSET CONTROLLER

MODEL 8682 SUREFLOW ADAPTIVE OFFSET CONTROLLER MODEL 8682 SUREFLOW ADAPTIVE OFFSET CONTROLLER INSTALLATION INSTRUCTIONS WARNING: The Model 8682 Adaptive Offset Controller must be wired to 24 VAC only. Wiring the unit to 110 VAC will cause serious unit

More information

900 Series Buccaneer BUCCANEER BUCCANEER

900 Series Buccaneer BUCCANEER BUCCANEER Terminals Sealing Gasket Retaining Nut Panel Body Contact Insert Locking Ring Main Body Contact Insert Terminals Cable Gland Gland Cage Gland Nut IP68 rating tested at 1.054kg/sq cm (15lb/sq in) 10m depth

More information

60A & 100A IEC 309 Watertight pin & sleeve devices

60A & 100A IEC 309 Watertight pin & sleeve devices Technical Data AH560R7W AH560C9W IP69K certified AH560P9W AH560B9W Product Description - North American 60A & 100A; 2-pole, 3-wire grounding; 3-pole, 4-wire grounding; 4-pole, 5-wire grounding Pin & sleeve

More information

Pixus Technologies Catalog

Pixus Technologies Catalog The Power of Embedded Ingenuity Pixus Technologies Catalog Kaparel, Ripac, & Vario Brand Products www.pixustechnologies.com sales@pixustechnologies.com US: 916.524.8242 CAN: 519.885.5775 Individual Subrack

More information

RoHS 2011/65/EU ISO 9001 ISO BS OHSAS 18001:2007 GREEN ELECTRONICS MCM. Terminal Blocks

RoHS 2011/65/EU ISO 9001 ISO BS OHSAS 18001:2007 GREEN ELECTRONICS MCM. Terminal Blocks RoHS 2011/65/EU e3 GREEN ELECTRONICS ISO 9001 ISO 14001 BS OHSAS 18001:2007 MCM Terminal Blocks MCM Functional characteristics Dimensional class: high RoHS 2011/65/EU Standard colour: green 0 Height: 14.45

More information

Fiber optic splice closure

Fiber optic splice closure FOSC-450A I N S T A L L A T I O N I N S T R U C T I O N TC-772-IP Rev A, Mar 2017 www.commscope.com Fiber optic splice closure Content 1 Introduction 2 General 2.1 Kit content 2.2 Tools 2.3 Accessories

More information

HelaGuard. Non-Metallic Conduit & Fittings

HelaGuard. Non-Metallic Conduit & Fittings HelaGuard Non-Metallic Conduit & Fittings HelaGuard Non-Metallic Conduit Systems Page HelaGuard Overview 3 Conduit Application Overview 4 Mounting & Removing HelaGuard Non-Metallic Fittings 5 HelaGuard

More information

2: Stylebox Stylebox 15 Overview B 2_ Complete Stylebox 15 Kits B 2_ Stylebox 15 Standard Kit B 2_8

2: Stylebox Stylebox 15 Overview B 2_ Complete Stylebox 15 Kits B 2_ Stylebox 15 Standard Kit B 2_8 2.1 Stylebox 15 Overview 2_3 2.1.1 Complete Stylebox 15 Kits 2_7 2.1.2 Stylebox 15 Standard Kit 2_8 2.2 Stylebox 15 Smart 2_10 2.2.1 Width 2_11 2.2.2 Height ezel 2_11 2.2.3 Depth 2_11 2.2.4 Top Cover Panel

More information

SHIELD-CONNECTION CLIPS SAB

SHIELD-CONNECTION CLIPS SAB SHIELD-CONNECTION CLIPS SAB PRODUCT INFORMATION CONTA-ELECTRONICS Shield-connection clips SAB Overview of the product line Description of the SABK shield-connection bracket system 3 Shield-connection bracket

More information

AVN. - Zone 2, 21, 22 - Lower maintenance costs - Easy to install - Suited to ambient temperatures of up to +55 C. Ex n. Stainless steel clips

AVN. - Zone 2, 21, 22 - Lower maintenance costs - Easy to install - Suited to ambient temperatures of up to +55 C. Ex n. Stainless steel clips AVN - Zone 2, 21, 22 - Lower maintenance costs - Easy to install - Suited to ambient temperatures of up to +55 C Transparent polycarbonate diffuser Stainless steel clips Polyamide cable gland and plug

More information

Selection BASIC LINE BASIC LINE PLUS VARIO LINE SERIES TUBE

Selection BASIC LINE BASIC LINE PLUS VARIO LINE SERIES TUBE PLUS 254 06_-Line A5_NEU_GB 22.01.12 21:56 Seite 255 - able carriers for movements For three-dimensional movements an be deployed on robots for swiveling and rotational movements: The same system for robot

More information

CABLE DRAG CHAIN SYSTEMS

CABLE DRAG CHAIN SYSTEMS CABLE DRAG CHAIN SYSTEMS MP 15 murrplastik Systemtechnik GmbH Postfach 1143 D-71567 Oppenweiler Tel. +49 (0) 7191/482-0 Fax +49 (0) 7191/482-280 www.murrplastik.de info@murrplastik.de 61 Order variants

More information

Data sheet C6 A modul 6 port 180 M GB3 pearl white

Data sheet C6 A modul 6 port 180 M GB3 pearl white Illustrations Dimensional drawing Page 1/7 See enlarged drawings at the end of document Product specification termination unit for mounting in service outlets for underfloor systems suitable for underfloor

More information

Empty enclosures IEC 62208

Empty enclosures IEC 62208 374 www.hensel-electric.de/en in accordance with for customized solutions and individual applications for example for low-voltage switchgear and controlgear assemblies i n accordance with the IEC 61439-series

More information

MULTIFIX 60 Universal Bus Bar Carriers

MULTIFIX 60 Universal Bus Bar Carriers MULTIFIX MULTIFIX BUS BAR SYSTEMS COMPONENTS FOR MM SYSTEMS FEATURES & BENEFITS MULTIFIX is a system for energy distribution comprising a variety of modular combinable components. The energy distribution

More information

1.6 Accessories include tool-free snap-in technology options for air flow, cable management, shelves, power distribution units, etc.

1.6 Accessories include tool-free snap-in technology options for air flow, cable management, shelves, power distribution units, etc. Rittal TS IT Rack Guide Specifications TS IT network server enclosure 1.0 General Description 1.1 Modular Free Standing Equipment Cabinet 1.2 Various combinations of dimensions: 1.2.1 Height: 48 /1200mm,

More information

SLiC Aerial Terminal and Spiral End Seal for use with AMP* Quiet Front Terminal Blocks

SLiC Aerial Terminal and Spiral End Seal for use with AMP* Quiet Front Terminal Blocks SLiC Aerial Terminal and Spiral End Seal for use with AMP* Quiet Front Terminal Blocks Instructions June 2002 78-8130-2161-1-B 1 Contents: 1.0 General... 3 2.0 Kit Contents... 3 3.0 Cable Preparation...

More information

Mineral-Insulated RTD Temperature Probe According to DIN EN 60751

Mineral-Insulated RTD Temperature Probe According to DIN EN 60751 ata Sheet 902210 Page 1/12 Mineral-Insulated RT Temperature Probe According to IN EN 60751 For temperatures from -50 (-200) to +600 C Flexible sheath cable with vibration-resistant measuring insert As

More information

14 HH EAC/CTP CE RoHS-II conform

14 HH EAC/CTP CE RoHS-II conform Outer jacket: Pressure extruded PUR mixture Inner jacket: Pressure extruded, gusset filling PUR mixture 12 cores or more: Bundles with optimized pitch length and pitch direction Conductor: Fine-wire strand

More information

Specifications are subject to change without notice. KSA-L15015-GC

Specifications are subject to change without notice. KSA-L15015-GC A member of the TSUBAKI GROUP 3D movement nylon open style able carriers for 3D movements For three-dimensional movements an be deployed on robots for swiveling and rotational movements: The same system

More information

60A & 100A IEC 309 Watertight pin & sleeve devices

60A & 100A IEC 309 Watertight pin & sleeve devices Technical Data AH560R7W AH560C9W IP69K certified AH560P9W AH560B9W Product Description - North American 60A & 100A; 2-pole, 3-wire grounding; 3-pole, 4-wire grounding; 4-pole, 5-wire grounding Pin & sleeve

More information

Dinosaur Flexible Wiring Duct

Dinosaur Flexible Wiring Duct Dinosaur Flexible Wiring Duct Dinosaur self-adhesive flexible duct is ideal for transporting wiring to cabinet doors from control panel interiors (for that part of the cable run that leans against the

More information

Data sheet E-DAT Industry RJ45 field plug black Cat.6 Class E A

Data sheet E-DAT Industry RJ45 field plug black Cat.6 Class E A Illustrations Dimensional drawing Page 1/7 See enlarged drawings at the end of document Product specification multi-port Cat.6 class E A plug to be assembled in the field compliance with class E A to ISO/IEC

More information

CRegulatory. Compliance: UL and CE APPENDIX C IN THIS CHAPTER. Installation Instructions Installation Guidelines System Installation Techniques

CRegulatory. Compliance: UL and CE APPENDIX C IN THIS CHAPTER. Installation Instructions Installation Guidelines System Installation Techniques APPENDIX C CRegulatory Compliance: UL and CE IN THIS CHAPTER Installation Instructions Installation Guidelines System Installation Techniques Appendix C Regulatory Compliance: UL and CE 81 Regulatory Agencies

More information

PCS-250 System Installation Instructions

PCS-250 System Installation Instructions PCS-250 System Installation Instructions Made in the USA PCS-250 System Specifications Page 1 TCU-250: Control PS-1000: Power Supply (optional) Input: 24VDC, 250mA Input Voltage: 110-240VAC Relay Outputs:

More information

RoHS 2011/65/EU GREEN ELECTRONICS MSG. Terminal Blocks ISO 9001 ISO BS OHSAS 18001:2007

RoHS 2011/65/EU GREEN ELECTRONICS MSG. Terminal Blocks ISO 9001 ISO BS OHSAS 18001:2007 RoHS 2011/65/EU e3 GREEN ELECTRONICS Terminal Blocks ISO 9001 ISO 14001 BS OHSAS 18001:2007 SAURO ELECTRONIC CONNECTORS WWW.SAURO.NET Standard PRODUCTS TERMINAL BLOCKS Functional characteristics s 270

More information

EWK Surface-mounted Field Distribution Boards, IP43

EWK Surface-mounted Field Distribution Boards, IP43 VT94514 Degree of protection IP43, IK09 Protection class II, fully insulated 160 mm enclosure depth Complete with door and installation field for add-on devices Combined plug-type terminals for neutral

More information

FIBER CONNECTOR SAFETY WARNINGS

FIBER CONNECTOR SAFETY WARNINGS FIBER CONNECTOR SAFETY WARNINGS SAFETY INFORMATION 1. Always wear safety glasses. 2. Isopropyl alcohol is flammable and may cause eye irritation. In case of contact with eyes, flush with water for at least

More information

Data sheet E-DAT modul 24x8(8) 1RU patch panel Cat.6 A, stainless steel

Data sheet E-DAT modul 24x8(8) 1RU patch panel Cat.6 A, stainless steel Illustrations Dimensional drawing Wiring Page 1/7 See enlarged drawings at the end of document Product specification 19 inch 1RU stainless steel module frame with 24 individual "E-DAT modul" modules component

More information

Wiring Duct T1 Series - Slotted

Wiring Duct T1 Series - Slotted Duct T1 Series - Slotted UL file E123572 T1 Series Gray Open Slot Rigid PVC (including cover) Catalog Standard Carton Package Quantity Price Catalog Single Piece Pkg Package Quantity Price T1-0506G 20

More information

Fuse Switch Disconnectors XNH. Fuse Switch Disconnectors XNH... For fuse links NH000 to NH3. Rated operating current of 160, 250, 400 and 630A

Fuse Switch Disconnectors XNH. Fuse Switch Disconnectors XNH... For fuse links NH000 to NH3. Rated operating current of 160, 250, 400 and 630A www.eaton.eu Panel Building Accessories PIFT Plug In Fused Terminal Fuse Disconnectors Thermostats Filters and Fans Terminals Electrical Cabinet Heating Catalogue 2016 Fuse Switch Disconnectors XNH Fuse

More information

13.1. Range of Enclosures. KRONECTION Box A 2 for up to 2 pairs. Expert Knowledge. Short survey of the KRONECTION Box A 2 for up to 2 pairs

13.1. Range of Enclosures. KRONECTION Box A 2 for up to 2 pairs. Expert Knowledge. Short survey of the KRONECTION Box A 2 for up to 2 pairs KRONECTION Box A 2 for up to 2 pairs Short survey of the KRONECTION Box A 2 for up to 2 pairs The KRONECTION Box A 2, which is equipped with connection contacts on the right and left, serves as a line

More information

CONTENTS. This Product is Certified by CANADIAN STANDARDS ASSOCIATION and Bears the Mark:

CONTENTS. This Product is Certified by CANADIAN STANDARDS ASSOCIATION and Bears the Mark: This Product is Listed by UNDERWRITERS LABORATORIES INC. and Bears the Mark: This Product is Certified by CANADIAN STANDARDS ASSOCIATION and Bears the Mark: SLATER SCD Installation Instructions For Self-Contained

More information

Wiring duct systems 77594_K01_15.indd I 77594_K01_15.indd I : :58

Wiring duct systems 77594_K01_15.indd I 77594_K01_15.indd I : :58 Wiring duct systems 77594_K01_15.indd I 04.12.12 09:58 BA7A, BA7B and HA7 Features and customer benefits Fire-retardant PVC or halogen-free construction for all applications and in compliance with all relevant

More information

Install Instruc & Recommended Procedures

Install Instruc & Recommended Procedures Install allation Instruc uctions & Recommended Procedures Unlike other radar detectors and aftermarket accessories, the K40 Calibre will not interfere with the vehicle's complex electronic systems. The

More information

MICRO-CON-X 2-7 NEW PRODUCT BULLETIN C708

MICRO-CON-X 2-7 NEW PRODUCT BULLETIN C708 FEATURES & BENEFITS Up to 7 contacts in compact design IP-67 rating, at the face (when mated) IP-67 molded cable assemblies (when mated) All plastic design is light weight Variety of standard options to

More information

I n t e r n a t i o n a l

I n t e r n a t i o n a l Solar Array Interconnect System SOLAR CONNECT Version 2, Edition 1. May 2012 Advantages for the Installer Plug & play layout design Simple time saving installation Pre-engineered, pre-fabricated, pre-tested

More information

900 Series Buccaneer BUCCANEER FOR POWER. IP68 rating tested at 1.054kg/sq cm (15lb/sq in) 10m depth for 2 weeks. Trailing Neutral on 5 pole

900 Series Buccaneer BUCCANEER FOR POWER. IP68 rating tested at 1.054kg/sq cm (15lb/sq in) 10m depth for 2 weeks. Trailing Neutral on 5 pole IP68 rating tested at 1.054kg/sq cm (15lb/sq in) 10m depth for 2 weeks 32A, 600V ac/dc rating 2, 3, 4, 5, 7 and 10 pole Plug or socket connection in each body style Water and dustproof to IP68 when mated

More information

Maximum performance. Always.

Maximum performance. Always. 54 Maximum performance. Always. Rotary control devices in box A23A A3 INSTALLATION LASS, ONDITIONAL SHORT IRUIT URRENT 0,000A. THEY ALLOW DIRET ONTROL OF HIGHLY INDUTIVE LOADS. THEY ELIMINATE OSTLY MAHINE

More information