1
2
3
4 CONTENTS Part I Intelligent Air Circuit Breaker(ACB) 01 UEW5 series Intelligent Air Circuit Breaker 02 Part II Molded Case Circuit Breaker(MCCB) 07 UEM5 series Molded Case Circuit Breakers 08 UEM5L series Molded Case Circuit Breaker with residual current protection 12 UEM5Z1 series electronic Molded Case Circuit Breaker s 13 Part III Automatic Transfer Switch(ATS) 14 UEQ5 Series automatic transfer switch 15 Part IV Terminal Circuit Breaker 18 UEB-63(H)series Miniature Circult breaker 19 UEHB-40 Miniature Circult breaker 25 UEBLM-40 series Electro-magnetic RCBO 29 UELM-100 series Electro-magnetic RCCB 32 UEBL-63(H)series RCBO 29 UEBL-40 series RCBO 43 UEB-100 series Miniature Circult breaker 46 UEB-63(100)Smart meters Dedicated Miniature Circult breakers 48 UES5 Series Surge Protective Device 52
5 1
6 UEW5 SERIES AIR CIRCUIT BREAKER UEW5 SERIES AIR CIRCUIT BREAKER UEW5 series intelligent air circuit breakers are applicable to the power distribution circuit under the condition of AC50Hz, rated working voltage 400V or 690V, rated current 630~6300A, this circuit breakers with high breaking capacity and Zero Flashover take the role of distributing power and protecting wires and equipments from being damaged by overload, under-voltage, short circuit and ground fault etc. The circuit breakers provide intelligent protection function and precise selective protection which will improve reliability and safety of power supply to avoid unnecessary power failure. Internal structure 1. Secondary circuit terminal(fixed) 5. Secondary circuit terminal (moving) 9. Operating mechanism 2. Safety clapboard 6. Shunt release 10. Motor-driven mechanism 3. Draw-out socket 7. Under-voltage release 11. Intelligent release 4. Auxiliary switch 8. Closing electromagnet 12. Enclosure 2
7 UEW5 SERIES AIR CIRCUIT BREAKER Type and meaning Intelligent air Design code Number of poles: Inteligent release: See Table 1 circuit breaker 3P,4P L,M,H,3M,3H UE W / M - Draw out - Accessories Manufacturer code: Frame current: Rated current Installation type: Xiamen Hongfa Electrical 2000,3200, (Refer to table2) Fixed,Draw-out Safety & Controls 4000,6300A Table 1 Required Accessories Optional accessories Intelligent release power supply Shunt release; Closing electromagnet Motor-driven mechanism Under-voltage release Auxiliary contact Opening lock Mechanical interlocking Frame Clapboard Hook Button locking equipment (user prepare the lock Power module (For intelligent controller) ST power module (For ST201 Relay module) ST201 Relay module AC400V,230V;DC220V,110V (Suitable power module is needed under DC con ) AC380V,220V;DC220V,110V AC380V,220V;Undervoltage instantaneous release (1S 3S 5S for option) 4 groups of transfer Switchings(Normal) 2NO,6NC 6 groups of transfer Switchings(Normal) 4NO,4NC 1 lock 1 key,2 locks 1 key,3 locks 2 keys Horizontal interlock, vertical interlock Provided along with breaker Installed in breaker before leaving factory DC220V,110V AC380V,220V;Output DC24V,Max 9.6W AC380V,220V(It's needed to meet function of remote control) 3
8 Table 2 main specification UEW5 SERIES AIR CIRCUIT BREAKER Type UEW Rated frame current Inm(A) 2000 Rated current In(A) Rated working voltage Ue(V) AC400 AC690 Rated insulation voltage Ui(V) AC690 AC1000 Number of poles Rated current of N pole IN(A) 50% or 100% In Rated ultimate short-circuit AC400V 80/85 80/85 80/85 80/85 80/85 80/85 breaking capacity Icu(kA) (effective value) AC690V 50/65 50/65 50/65 50/65 50/65 50/65 Rated service short-circuit AC400V 50/85 50/85 50/85 50/85 50/85 50/85 breaking capacity Ics(kA) (effective value) AC690V 50/65 50/65 50/65 50/65 50/65 50/65 Rated short circuit making AC400V 176/ / / / / /187 capacity Icm(kA) (peak value) AC690V 105/ / / / / /145 Rated short time withstand AC400V 50/85 50/85 50/85 50/85 50/85 50/85 current (1s)Icw(kA) (effective value) AC690V 40/65 40/65 40/65 40/65 40/65 40/65 Full breaking time (without additional delay) (ms) 25~30 Closing time(ms) 70 at maximum Basic Multi-functio Intelligent controller nal Communicati on Dielectric performance 50Hz AC 2500V 1min AC400V Electrical life AC690V Operational Non-mainten performance Mechanical life ance Maintenance Connection pattern horizontal horizontal horizontal horizontal horizontal horizontal vertical vertical vertical vertical vertical vertical Pattern Externality dimensions HxWxL(mm) Draw-out Fixed Fixed 3P 395x362x323 Fixed 4P 395x457x323 Draw-out 3P 433x375x420 Draw-out 4P 430x470x420 4
9 Table 2 main specification UEW5 SERIES AIR CIRCUIT BREAKER Type Rated frame current Inm(A) Rated current In(A) Rated working voltage Ue(V) Rated insulation voltage Ui(V) Number of poles Rated current of N pole IN(A) Rated ultimate short-circuit breaking capacity Icu(kA) (effective value) Rated service short-circuit breaking capacity Ics(kA) (effective value) Rated short circuit making capacity Icm(kA) (peak value) Rated short time withstand current (1s) Icw(kA) (effective value) AC400V AC690V AC400V AC690V AC400V AC690V AC400V AC690V Full breaking time (without additional delay) (ms) Intelligent controller Operational performance Closing time(ms) Dielectric performance Electrical life Mechanical life Pattern Basic Multi-functional Communication 50Hz AC400V AC690V Non-maintenance Maintenance Connection pattern Externality dimensions HxWxL (mm) Draw-out Fixed Fixed 3P Fixed 4P Draw-out 3P Draw-out 4P UEW AC400 AC690 AC690 AC % or 100% In 100/ / / /110 65/85 65/85 65/85 65/85 80/100 80/100 80/100 80/100 65/85 65/85 65/85 65/85 220/ / / / / / / /187 80/100 80/100 80/100 80/100 50/85 50/85 50/85 50/85 25~30 70 at maximum AC 2500V 1min horizontal vertical horizontal vertical horizontal vertical horizontal vertical 395x422x x544x x435x x550x420 5
10 Table 2 main specification UEW5 SERIES AIR CIRCUIT BREAKER Type Rated frame current Inm(A) Rated current In(A) Rated working voltage Ue(V) Rated insulation voltage Ui(V) Number of poles Rated current of N pole IN(A) Rated ultimate short-circuit breaking capacity Icu(kA) (effective value) Rated service short-circuit breaking capacity Ics(kA) (effective value) Rated short circuit making capacity Icm(kA) (peak value) Rated short time withstand current (1s)Icw(kA) (effective value) AC400V AC690V AC400V AC690V AC400V AC690V AC400V AC690V Full breaking time (without additional delay) (ms) Closing time(ms) Operational performanc e Basic Multi-functional Intelligent controller Communication Dielectric performance 50Hz Electrical AC400V life AC690V Mechanical Non-maintenance life Maintenance Connection pattern Pattern Externality dimensions HxWxL(mm) Draw-out Fixed Fixed 3P Fixed 4P Draw-out 3P Draw-out 4P UEW UEW AC400 AC690 AC690 AC % or 100% In 110/ / / / / /135 75/85 75/85 75/85 75/100 75/100 75/100 85/120 85/120 85/ / / /135 65/85 65/85 65/85 65/100 65/100 65/ / / / / / / / / / / / /220 85/120 85/120 85/ / / /135 65/85 65/85 65/85 65/100 65/100 65/100 25~30 Max.70 AC 2500V 1min horizont horizont horizont horizontal horizontal horizontal al al al 433x550x x788x x930(813)x x930x486 6
11 7
12 UEM5 SERIES MOLDED CASE CIRCUIT BREAKERS UEM5 SERIES MOLDED CASE CIRCUIT BREAKERS UEM5Series Molded Case Circuit Breakers (MCCB for short below) are applicable to the electrical network under the condition of AC50Hz, rated working current 10A - 800A, rated insulation voltage 800V and rated working voltage 400V or below. MCCB has overload, short-circuit and under-voltage protection performances, among which the UEM5L series residual current circuit breakers can be used to protect human body and equipment from electric shock and residual current, as well as to prevent from fire danger due to earth-fault current which is caused by equipment insulation damage. Normally, the circuit breakers also take the role of infrequent turn-on or turn-off and infrequent motor starting-up. The series circuit breaker with isolation function, it's corresponding symbol is ". 8
13 UEM5 SERIES MOLDED CASE CIRCUIT BREAKERS Product feature The casing like base and cover, which is made of the USA IDI company s thermosetting material, has high quality in strength and insulation, so as to ensure the breakers performance reliably. Advanced design of operation mechanism, rapid breaking and slight tripping force. Adopting the Double-way breaking system, not only reducing the circuit breaker s cubage, but greatly improving the short circuit breaking capacity as well. The contact system adopts the principle of electromagnetic repulsion. Once there is fault current, the electromagnetic repulsion can separate the moving and stationary contacts rapidly, and increases the spacing, so as to achieve current limiting and improve the breaking capacity. The circuit breakers of the same rated current frame and different breaking capacity share the absolutely identical dimensions of externality and installation, which can extremely improve the interchangeability. The design of cassette-type accessories (including shunt release, under-voltage release, auxiliary contact and alarm contact) insures the flexibility of control function. The user can install them without opening the cover, and need not any adjustment. Since adopting design of the insulation box, the operation security has been improved. The UEM5L series residual MCCB have reliable low-voltage protection, which have insured the residual current protection to work normally even with the line voltage low to 50V. For one product, not only the residual operating current can be adjusted, but operating time s non-delay and delay can be adjustable as well, furthermore, can open or close the residual current protection based on customers requirements, which have improved the operation flexibility. The rated insulation voltage up to 800V, rated impulse withstands voltage up to 8000V, which can meet the application requirement of switch cabinet. Using the world's most advanced alloy material movement contacts to ensure high mechanical life and electrical life. The full range of products has two invention patents, nine utility model patents and three appearance patents,which make products novelty, aesthetics, reliability, and security. 9
14 Type and meaning Derivative Code No code: Thermal & magnetic compound over-current release, without residual current protection. L: Thermal & magnetic compound over-current release, with residual current protection. Short circuit breakers capacity L: Standard M: Relatively high breaking H: High breaking R: Conditional current Number of poles 3:3 poles 4:4poles Application code No code: power distribution protection 2: motor protection No code: Front fix (no connect board) Q:Front fix (with connect board) H: Back fix R: Plug in Z1: intelligent over-current release, without residual current protection. UEM5 L L P / A H Manufacturer code: Xiamen Hongfa Electrical Safety & Controls Co., Ltd. Rated Frame Current: Operation Pattern No code: Handle operation P:motor-driven Z:turning handle Rated current Code for release pattern and internal accessories 200- electromagnetic protection 300- compound protection Refer to the release pattern and internal accessories codes in detail The N-pole of the four-pole products has four types: A, B, C and D. Type A: N-pole without over-current release, it has been connected all along, and does not act with other three poles. Type B: N-pole without over-current release, it could act with other three poles. Type C: N-pole fixed with over-current release, it could act with other three poles. Type D: N-pole fixed with over-current release, it has been connected all along, and does not act with other three poles 10
15 UEM5 SERIES MOLDED CASE CIRCUIT BREAKERS Main technical parameter With a modular design, we can organically combine Thermal & magnetic, electronic and residual current operated protection, to form UEM5 molded case circuit breaker, UEM5L residual current circuit breaker, UEM5Z1 electronic molded case circuit breaker. UEM5 series MCCB Rated frame current (A) Type Rated current In(A) L M H R L M H R L M H R L M H R L M H R Pole number 3 / / / 4 3 / 4 3 / 4 3 / 4 Rated insulation voltage Ui (V) AC800 AC800 AC800 AC800 AC800 AC800 Rated working voltage Ue (V) AC400 AC400 AC400 AC400 AC400 AC400 Rated impulse withstand voltage Uimp (V) Arc-over distance (mm) Use category A A A A A A Pollution grade Rated ultimate short-circuit breaking capacity Icu(kA) AC400V Rated short-circui breaking capacityi (ka) Dimension(mm) a 90 / / / / / / 280 b Wirin g Matho d Acces sories c d Front fix Back fix Plug in Shunt release Under-voltage release Auxiliary contact Alarm contact Motor-driven Turning handle Back fix accessories Protection function over-current release device Weight(kg) Overload, short circuit Thermal & magnetic 1.3/2.2 Overload, short circuit Thermal & magnetic L:1.3 M H R:1.6/2.5 Overload, short circuit Thermal & magnetic L:1.5 M H R:2.0/2.9 Overload, short circuit Thermal & magnetic Overload, short circuit Thermal & magnetic Overload, short circuit Thermal & magnetic 6.2/8 7.2/ /
16 UEM5 SERIES MOLDED CASE CIRCUIT BREAKERS UEM5L series MCCB Rated frame current (A) Type M H R M H R M H R M H R M H R Rated current In(A) Pole number 3 / 4 3 / 4 3 / 4 3 / 4 3 / 4 Nondelay Rated residual operating current I n (ma) 30/100/300 Adjustable 30/100/300 Adjustable 100/300/500Adj ustable 300/500/1000 Adjustable 5I n Max.Disconnect time (s) Rated residual operating current I n (ma) 30/100/300 Adjustable 30/100/300 Adjustable 100/300/500 Adjustable 300/500/1000 Adjustable Delay 2I n Max. disconnect time (s) I n Limiting non-actuating time t(s) Residual current indication button Button Button Button Button Button Rated insulation voltage Ui(V) AC800 AC800 AC800 AC800 AC800 Rated working voltage Ue(V) AC400 AC400 AC400 AC400 AC400 Rated impulse withstand voltage Uimp (V) Arc-over distance (mm) Use category A A A A A Pollution grade Rated ultimate short-circuit breaking capacity Icu (ka) Rated working short-circuit breaking capacity I (ka) AC400V a 90 / / / / / 280 b Dimension(mm) c d Front fix Wiring Mathod Accessories Back fix Plug in Shunt release Under-voltage release Auxiliary contact Alarm contact Motor-driven Turning handle Back fix accessories Overload, short Overload, short Overload, short Overload, short Overload, short Protection function circuit, residual circuit, residual circuit, residual circuit, residual circuit, residual current current current current current over-current release device Thermal & Thermal & Thermal & Thermal & Thermal & magnetic magnetic magnetic magnetic magnetic Operating characteristic AC AC AC AC AC 12
17 UEM5 SERIES MOLDED CASE CIRCUIT BREAKERS UEM5Z1 series electronic molded case circuit breakers Rated Frame Current (A) Type M H R M H R M H R M H R Rated current In(A) 16-32(Adjustabl e) (Adjusta ble) (Adj ustable) (Ad justable) (Adjustable) Pole number 3/4 3/4 3 / 4 3 / 4 Rated insulation voltage Ui(V) AC800 AC800 AC800 AC800 Rated working voltage Ue(V) AC400 AC400 AC400 AC400 Rated impulse withstand voltage Uimp (V) Arc-over distance (mm) Use category A A B B Pollution grade Rated ultimate short-circuit breaking capacity Icu (ka) AC400V Rated working short-circuit breakin capacity Ics(kA) Rated short-time withstand currenticw(ka/s) Dimensio(mm) a 90/ / / / 280 Wiring Mathod Accessories Protection function b c d Front fix Back fix Plug in Shunt release Under-voltage release Auxiliary contact Alarm contact Motor-driven Turning handle Back fix accessories over-current release device Overload, short-circuit short delay, instantaneous short circuit current Electronic type(adjustable) Overload, short-circuit short delay, instantaneous short circuit current Electronic type(adjustable ) Overload, short-circuit short delay, instantaneous short circuit current Electronic type(adjustable ) Overload, short-circuit short delay, instantaneous short circuit current Electronic type(adjustable) Operating characteristic 1.6/ / / /
18 14
19 UEQ5 SERIES AUTOMATIC TRANSFER SWITCH UEQ5 SERIES AUTOMATIC TRANSFER SWITCH UEQ5 Series automatic transfer switching is applicable to the double-circuit power supply (power distribution to power distribution, or power distribution to generator), rated frequency 50HZ, and rated voltage 400V. The power is shifted automatically when one power breaks down, which ensures the reliability and safety of the power supply and makes the power switch to achieve the intelligent unmanned operation and remote control. This device adopts a motor-driven operation mechanism with patent technique, providing with multifunctional intelligent controllers to meet various market demands. This device conforms to GB/T standard. 15
20 Type and meaning Rated Frame Current: Switch rating: 2,3,4 Current type: A:Grid(Defauld) B:Grid-Generator Non-standard components: X:Fire function T:Communication 300B:Release UEQ5-100 M / Y A R (X) Manufacturer code: Xiamen Hongfa Electrical Safety & Controls Co., Ltd. Short-circuit breaking capacity level is M (Default) H Rated Current(A): 6-63, , , , Controller: Y-Seperated body F- Divided body Working method : R: Automatic change and automatic recovery S:Automatic change and not automatic recovery UEQ5 Note: Switch rating:2 poles(only for frame of UEQ5-63 ) Power type: Grid-grid(Defauld) Working type: Automatic change and automatic recovery device. Implementation of circuit breaker:300b(default);differnt releases for option. Non-standard components: X:Fire function Fire fighting linkage function,input voltage:14vac/24vdc T:Communication UEQ5-63: Only with one-body structure(y) grid-grid function(a). 16
21 UEQ5 SERIES AUTOMATIC TRANSFER SWITCH Main technical parameter Automatic transfer switch Type UEQ5-63 UEQ5-100 UEQ5-250 Implementation of circuit breaker XMB0-63 UEM5-100 UEM5-250 Rated insulation voltage Ui (V) Rated operating voltage Ue (V) 230/ Rated impulse withstand voltage voltage Uimp (kv Rated current In (A) Number of poles Rated short circuit making capacity Icm (ka) / /105 Rated short-circuit breaking capacity Icn (ka) 5 75/50 75/50 Conversion time (without delay settings) s <2s Mechanical life (times) Overload protection Short-circuit protection Optional* With Implementation of circuit breaker UEM5-400 UEM5-800 Rated insulation voltage Ui (V) 800 Rated operating voltage Ue (V) 400 Rated impulse withstand voltage voltage Uimp (kv 8 Rated current In (A) Number of poles 3 4 Rated short circuit making capacity Icm (ka) 220/ /105 Rated short-circuit breaking capacity Icn (ka) 100/50 100/50 Conversion time (without delay settings) s <2.5s Mechanical life (times) 5000 Overload protection Short-circuit protection Optional* With 17
22 18
23 UEB-63 (H) SERIES RCBO UEB-63 (H) SERIES RCBO UEB-63 (H) series miniature circuit breaker (MCB) mainly used in the circuit of AC 50/60Hz, rated voltage 230V/400V, rated current under 63A, to protect the circuit and electric equipments of building and the similar places from over current and short circuit, it s also applicable for the infrequent switch-on and switch-off operation. The breaking capacity up to 10kA, which is of good current limit for short circuit, to avoid and reduce the damage of short circuit current on circuit and equipment. Technical parameter Type UEB-63 UEB-63H Standard IEC60898 Number of poles 1, 2, 3, 4 Tripping characteristic B,C,D Breaking capacity Icu 6kA 10kA Rated current In 1A~63A Rated voltage AC one pole Un 230V/400V AC multi pole Un 400V Frequency Hz Mechanical life (cycles) Electrical life (cycles) Rated insulation Ui 500V Rated impulse withstand voltage (1.2/50)Uimp 6000V Power-frequency dielectric strength 2kV Protection class Terminal IP20 Other parts IP40 Ambient temperature Operation temp. -25~+55 Storage temp. -40~+70 Humidity Constant humidity 23/83,40/93,55/20 Relative humidity 25/95,40/95 Wiring mm² Torque Nm
24 UEB-63 (H) SERIES RCBO Tripping characteristic Type and meaning Products:MCB Interruptive capacity, H for 10kA, no code for 6kA Rated Current: 1A, 2A, 3A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A UE B - 63 (H) B 16 / 1P Manufacturer code: Xiamen Hongfa Electrical Maximum rated current Tripping characteristic: Type B, C, D Number of poles: 1P, 2P, 3P, 4P Safety & Controls Co., Ltd. 20
25 UEB-63 (H) SERIES RCBO Feature Conform to IEC standard with isolated feature The current limit is better than standard EN60898 requirement class Ⅲ New appearance, handle with anti-sliding arc design Malfunction display window, easy for maintenance personnel check the cause of malfunction. Dimensions (mm) Products selection table UEB-63 series Number of poles Type B Type C Type D Rated current Breaking capacity UEB-63 B1/1P UEB-63 C1/1P UEB-63 D1/1P 1A UEB-63 B2/1P UEB-63 C2/1P UEB-63 D2/1P 2A UEB-63 B3/1P UEB-63 C3/1P UEB-63 D3/1P 3A UEB-63 B4/1P UEB-63 C4/1P UEB-63 D4/1P 4A UEB-63 B6/1P UEB-63 C6/1P UEB-63 D6/1P 6A 1P UEB-63 B10/1P UEB-63 C10/1P UEB-63 D10/1P 10A UEB-63 B16/1P UEB-63 C16/1P UEB-63 D16/1P 16A 6kA UEB-63 B20/1P UEB-63 C20/1P UEB-63 D20/1P 20A UEB-63 B25/1P UEB-63 C25/1P UEB-63 D25/1P 25A UEB-63 B32/1P UEB-63 C32/1P UEB-63 D32/1P 32A UEB-63 B40/1P UEB-63 C40/1P UEB-63 D40/1P 40A UEB-63 B50/1P UEB-63 C50/1P UEB-63 D50/1P 50A UEB-63 B63/1P UEB-63 C63/1P UEB-63 D63/1P 63A 21
26 UEB-63 (H) SERIES RCBO Products selection table UEB-63 series Number of poles Type B Type C Type D Rated current Breaking capacity UEB-63 B1/2P UEB-63 C1/2P UEB-63 D1/2P 1A UEB-63 B2/2P UEB-63 C2/2P UEB-63 D2/2P 2A UEB-63 B3/2P UEB-63 C3/2P UEB-63 D3/2P 3A UEB-63 B4/2P UEB-63 C4/2P UEB-63 D4/2P 4A UEB-63 B6/2P UEB-63 C6/2P UEB-63 D6/2P 6A 2P UEB-63 B10/2P UEB-63 C10/2P UEB-63 D10/2P 10A UEB-63 B16/2P UEB-63 C16/2P UEB-63 D16/2P 16A 6kA UEB-63 B20/2P UEB-63 C20/2P UEB-63 D20/2P 20A UEB-63 B25/2P UEB-63 C25/2P UEB-63 D25/2P 25A UEB-63 B32/2P UEB-63 C32/2P UEB-63 D32/2P 32A UEB-63 B40/2P UEB-63 C40/2P UEB-63 D40/2P 40A UEB-63 B50/2P UEB-63 C50/2P UEB-63 D50/2P 50A UEB-63 B63/2P UEB-63 C63/2P UEB-63 D63/2P 63A UEB-63 B1/3P UEB-63 C1/3P UEB-63 D1/3P 1A UEB-63 B2/3P UEB-63 C2/3P UEB-63 D2/3P 2A UEB-63 B3/3P UEB-63 C3/3P UEB-63 D3/3P 3A UEB-63 B4/3P UEB-63 C4/3P UEB-63 D4/3P 4A UEB-63 B6/3P UEB-63 C6/3P UEB-63 D6/3P 6A 3P UEB-63 B10/3P UEB-63 C10/3P UEB-63 D10/3P 10A UEB-63 B16/3P UEB-63 C16/3P UEB-63 D16/3P 16A 6kA UEB-63 B20/3P UEB-63 C20/3P UEB-63 D20/3P 20A UEB-63 B25/3P UEB-63 C25/3P UEB-63 D25/3P 25A UEB-63 B32/3P UEB-63 C32/3P UEB-63 D32/3P 32A UEB-63 B40/3P UEB-63 C40/3P UEB-63 D40/3P 40A UEB-63 B50/3P UEB-63 C50/3P UEB-63 D50/3P 50A UEB-63 B63/3P UEB-63 C63/3P UEB-63 D63/3P 63A UEB-63 B1/4P UEB-63 C1/4P UEB-63 D1/4P 1A UEB-63 B2/4P UEB-63 C2/4P UEB-63 D2/4P 2A UEB-63 B3/4P UEB-63 C3/4P UEB-63 D3/4P 3A UEB-63 B4/4P UEB-63 C4/4P UEB-63 D4/4P 4A UEB-63 B6/4P UEB-63 C6/4P UEB-63 D6/4P 6A UEB-63 B10/4P UEB-63 C10/4P UEB-63 D10/4P 10A 4P UEB-63 B16/4P UEB-63 C16/4P UEB-63 D16/4P 16A 6kA UEB-63 B20/4P UEB-63 C20/4P UEB-63 D20/4P 20A UEB-63 B25/4P UEB-63 C25/4P UEB-63 D25/4P 25A UEB-63 B32/4P UEB-63 C32/4P UEB-63 D32/4P 32A UEB-63 B40/4P UEB-63 C40/4P UEB-63 D40/4P 40A UEB-63 B50/4P UEB-63 C50/4P UEB-63 D50/4P 50A UEB-63 B63/4P UEB-63 C63/4P UEB-63 D63/4P 63A 22
27 UEB-63 (H) SERIES RCBO UEB-63H Series Number of poles Type B Type C Type D Rated current Breaking capacity UEB-63H B1/1P UEB-63H C1/1P UEB-63H D1/1P 1A UEB-63H B2/1P UEB-63H C2/1P UEB-63H D2/1P 2A UEB-63H B3/1P UEB-63H C3/1P UEB-63H D3/1P 3A UEB-63H B4/1P UEB-63H C4/1P UEB-63H D4/1P 4A UEB-63H B6/1P UEB-63H C6/1P UEB-63H D6/1P 6A 1P UEB-63H B10/1P UEB-63H C10/1P UEB-63H D10/1P 10A UEB-63H B16/1P UEB-63H C16/1P UEB-63H D16/1P 16A 10kA UEB-63H B20/1P UEB-63H C20/1P UEB-63H D20/1P 20A UEB-63H B25/1P UEB-63H C25/1P UEB-63H D25/1P 25A UEB-63H B32/1P UEB-63H C32/1P UEB-63H D32/1P 32A UEB-63H B40/1P UEB-63H C40/1P UEB-63H D40/1P 40A UEB-63H B50/1P UEB-63H C50/1P UEB-63H D50/1P 50A UEB-63H B63/1P UEB-63H C63/1P UEB-63H D63/1P 63A UEB-63H B1/2P UEB-63H C1/2P UEB-63H D1/2P 1A UEB-63H B2/2P UEB-63H C2/2P UEB-63H D2/2P 2A UEB-63H B3/2P UEB-63H C3/2P UEB-63H D3/2P 3A UEB-63H B4/2P UEB-63H C4/2P UEB-63H D4/2P 4A UEB-63H B6/2P UEB-63H C6/2P UEB-63H D6/2P 6A 2P UEB-63H B10/2P UEB-63H C10/2P UEB-63H D10/2P 10A UEB-63H B16/2P UEB-63H C16/2P UEB-63H D16/2P 16A 10kA UEB-63H B20/2P UEB-63H C20/2P UEB-63H D20/2P 20A UEB-63H B25/2P UEB-63H C25/2P UEB-63H D25/2P 25A UEB-63H B32/2P UEB-63H C32/2P UEB-63H D32/2P 32A UEB-63H B40/2P UEB-63H C40/2P UEB-63H D40/2P 40A UEB-63H B50/2P UEB-63H C50/2P UEB-63H D50/2P 50A UEB-63H B63/2P UEB-63H C63/2P UEB-63H D63/2P 63A 23
28 UEB-63 (H) SERIES RCBO UEB-63H series Number of poles Type B Type C Type D Rated current Breaking capacity UEB-63H B1/3P UEB-63H C1/3P UEB-63H D1/3P 1A UEB-63H B2/3P UEB-63H C2/3P UEB-63H D2/3P 2A UEB-63H B3/3P UEB-63H C3/3P UEB-63H D3/3P 3A UEB-63H B4/3P UEB-63H C4/3P UEB-63H D4/3P 4A UEB-63H B6/3P UEB-63H C6/3P UEB-63H D6/3P 6A 3P UEB-63H B10/3P UEB-63H C10/3P UEB-63H D10/3P 10A UEB-63H B16/3P UEB-63H C16/3P UEB-63H D16/3P 16A 10kA UEB-63H B20/3P UEB-63H C20/3P UEB-63H D20/3P 20A UEB-63H B25/3P UEB-63H C25/3P UEB-63H D25/3P 25A UEB-63H B32/3P UEB-63H C32/3P UEB-63H D32/3P 32A UEB-63H B40/3P UEB-63H C40/3P UEB-63H D40/3P 40A UEB-63H B50/3P UEB-63H C50/3P UEB-63H D50/3P 50A UEB-63H B63/3P UEB-63H C63/3P UEB-63H D63/3P 63A UEB-63H B1/4P UEB-63H C1/4P UEB-63H D1/4P 1A UEB-63H B2/4P UEB-63H C2/4P UEB-63H D2/4P 2A UEB-63H B3/4P UEB-63H C3/4P UEB-63H D3/4P 3A UEB-63H B4/4P UEB-63H C4/4P UEB-63H D4/4P 4A UEB-63H B6/4P UEB-63H C6/4P UEB-63H D6/4P 6A 4P UEB-63H B10/4P UEB-63H C10/4P UEB-63H D10/4P 10A UEB-63H B16/4P UEB-63H C16/4P UEB-63H D16/4P 16A 10kA UEB-63H B20/4P UEB-63H C20/4P UEB-63H D20/4P 20A UEB-63H B25/4P UEB-63H C25/4P UEB-63H D25/4P 25A UEB-63H B32/4P UEB-63H C32/4P UEB-63H D32/4P 32A UEB-63H B40/4P UEB-63H C40/4P UEB-63H D40/4P 40A UEB-63H B50/4P UEB-63H C50/4P UEB-63H D50/4P 50A UEB-63H B63/4P UEB-63H C63/4P UEB-63H D63/4P 63A 24
29 UEHB-40 (H) MCB UEHB-40(H) MCB UEHB-40(H) household circuit breaker is applicable in the circuit of AC 50Hz/60Hz, rated voltage 230V,rated current to 40A,as the overload and short circuit protection, it s also applicable for the infrequent switch-on and switch-off operation. Technical parameter Type UEHB-40 UEHB-40H Standard IEC EN Number of poles 1P+N Tripping characteristic B,C Breakging capacity Icu 4.5kA 6kA Rated current In 1A ~40A Rated voltage Un 230V Frequency Hz Mechanical life(cycles) Electrical life (cycles) 6000 Rated insulation Ui 300V Rated impulse withstand voltage 4000V (1.2/50)Uimp Power-frequency dielectric strength 2kV Protection Terminal IP20 class Other parts IP40 Ambient Operation temp. -5~+55 temperature Storage temp. -25~+70 Humidity Constant humidity 23/83,40/93,55/20 Relative humidity 25/95,40/95 Wiring mm² Torque Nm
30 Type and meaning Products:MCB for household Breaking capacity, H for 6kA, no code for 4.5kA Rated Current: 1A, 2A, 3A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A UE HB - 40 (H) B 16 Manufacturer code: Xiamen Hongfa Electrical Safety & Controls Co., Ltd. Maximum rated current Tripping characteristic: Type B, C 26
31 UEHB-40 (H) MCB Feature Cut off both phase and neutral line, high safety performance, avoid the potential damage that single phase circuit breaker didn t cut off neutral line. The current limit reach to standard EN60898 requirement class Ⅲ Malfunction display window, easy for maintenance personnel check the cause of malfunction. Tripping characteristic curve Dimensions (mm) 27
32 UEHB-40 (H) MCB Products selection table UEHB-40 series Pole no. Type B Type C Rated current Breaking capacity UEHB-40 B1 UEHB-40 C1 1A UEHB-40 B2 UEHB-40 C2 2A UEHB-40 B3 UEHB-40 C3 3A UEHB-40 B4 UEHB-40 C4 4A UEHB-40 B6 UEHB-40 C6 6A 1P+N UEHB-40 B10 UEHB-40 C10 10A 4.5kA UEHB-40 B16 UEHB-40 C16 16A UEHB-40 B20 UEHB-40 C20 20A UEHB-40 B25 UEHB-40 C25 25A UEHB-40 B32 UEHB-40 C32 32A UEHB-40 B40 UEHB-40 C40 40A UEHB-40H series Pole no. Type B Type C Rated current Breaking capacity UEHB-40 B1 UEHB-40 C1 1A UEHB-40 B2 UEHB-40 C2 2A UEHB-40 B3 UEHB-40 C3 3A UEHB-40 B4 UEHB-40 C4 4A UEHB-40 B6 UEHB-40 C6 6A 1P+N UEHB-40 B10 UEHB-40 C10 10A 6kA UEHB-40 B16 UEHB-40 C16 16A UEHB-40 B20 UEHB-40 C20 20A UEHB-40 B25 UEHB-40 C25 25A UEHB-40 B32 UEHB-40 C32 32A UEHB-40 B40 UEHB-40 C40 40A 28
33 UEBLM-40 SERIES ELECTRO-MAGNETIC RCBO UEBLM-40 SERIES ELECTRO-MAGNETIC RCBO UEBLM-40 series residual current circuit breaker with overload protection (RCBO) mainly used in the circuit of AC 50/60Hz, rated voltage 230V, rated current 40A, to protect the circuit and electric equipments of building and personnel from over current, short circuit and residual current, once the residual current exceeds the specified value, the RCBO can cut off the failure power immediately to protect the safety of personnel and equipments, it s also applicable for the infrequent switch-on and switch-off operation. Technical parameter Type UEBLM-40 Standard IEC Number of poles 1P+N Tripping characteristic B,C Tripping type Electro-Magnetic Interruptive capacity Icu 6kA Rated current In 1A~40A Rated voltage Un 230V Residual operating current ma 30 Frequency Hz Rated insulation Ui 500V Rated impulse withstand voltage(1.2/50)uimp 6000V Power-frequency dielectric strength 2kV Mechanical life(cycles) Electrical life (cycles) Leakage life(cycles) 4000 Pollution degree 2 Protection class Terminal IP20 Other parts IP40 Ambient temperature Operation temp. -5~+55 Storage temp. -25~+70 Humidity Constant humidity 23/83,40/93,55/20 Relative humidity 25/95,40/95 Wiring mm Torque Nm
34 UEBLM-40 SERIES ELECTRO-MAGNETIC RCBO Type and meaning Products: Circuit breaker Maximum rated current Rated Current: 1A, 2A, 3A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A UE B - LM 40 B 16 Manufacturer code: Xiamen Hongfa Electrical Safety & Controls Co., Ltd. Electro-Magnetic residual current protection Tripping characteristic: Type B, C Feature Can provide the reliable protection when there's fault on the line voltage (such as voltage decrease or neutral line off), electromagnetic compatibility (EMC) is good, and no sensitive to over-voltage. It s of the all features of UEB-63 series. It s of the protection function of over current, short circuit and residual current. Tripping characteristic curve 30
35 Dimensions (mm) UEBLM-40 SERIES ELECTRO-MAGNETIC RCBO Products selection table UEBLM-40 series Pole no. Type B Type C Rated current Breaking capacity UEBLM-40 B1 UEBLM-40 C1 1A UEBLM-40 B2 UEBLM-40 C2 2A UEBLM-40 B3 UEBLM-40 C3 3A UEBLM-40 B4 UEBLM-40 C4 4A UEBLM-40 B6 UEBLM-40 C6 6A 1P+N UEBLM-40 B10 UEBLM-40 C10 10A 6kA UEBLM-40 B16 UEBLM-40 C16 16A UEBLM-40 B20 UEBLM-40 C20 20A UEBLM-40 B25 UEBLM-40 C25 25A UEBLM-40 B32 UEBLM-40 C32 32A UEBLM-40 B40 UEBLM-40 C40 40A 31
36 UELM-100(H) SERIES ELECTRO-MAGNETIC RCCB UELM-100(H) SERIES ELECTRO-MAGNETIC RCCB UELM-100(H) series residual current circuit breaker (RCCB) mainly used in the circuit of AC 50/60Hz, rated voltage 400V, rated current 100A, once the residual current exceeds the specified value, the RCCB can cut off the failure power immediately to protect the safety of personnel and equipments, it s also applicable for the infrequent switch-on and switch-off operation. Technical parameter Standard Number of poles Residual current tripping type Type UELM-100 UELM-100(H) IEC P, 4P AC, A Rated limited short-circuit current Inc 6kA 10kA Rated limited residual current I C 6kA 10kA SCPD short-circuit current Rated current In Rated voltage Un A 25A, 32A, 40A, 50A, 63A, 80A, 100A 230V/400V Residual operating current I n ma 30mA, 100mA, 300mA Operating time under I n Frequency Hz 0.1s 50Hz-60Hz Mechanical life(cycles) Electrical life (cycles) Leakage life(cycles) Rated insulation voltage Ui Rated impulse withstand voltage(1.2/50)uimp Power-frequency dielectric strength Pollution degree 2 Protection class Ambient temperature Humidity Terminal Other parts 500V 6 000V 2.5kV IP20 IP40 Operation temp. -5~+55 Storage temp. -25~70 Constant humidity 23/83,40/93,55/20 Relative humidity 25/95,40/95 Wiring mm Torque Nm 2.5 Installation Wiring EN60715(35mm) DIN-rail installation bus bar terminal, Tunnel pressure type connection 32
37 Feature UELM-100(H) SERIES ELECTRO-MAGNETIC RCCB Can provide the reliable protection when there's fault on the line voltage (such as voltage decrease or neutral line off), good electromagnetic compatibility (EMC), and no sensitive to over-voltage. Residual display window, easy for maintenance personnel check the cause of malfunction. Modular design, easy for installation Short-circuit limited current up to 10kA Type Designation: Products: Electro-magnetic RCCB Rated limited short-circuit current: H for 10kA, no code for 6kA Rated current: 25:25A,,32:32A,40:40A, 50:50A,63:63A, 80:80A, 100:100A Residual operational current: 30:30Ma,100:100mA, 300:300mA UE LM (H) 2P 63 A A 30 Manufacturer code: Xiamen Hongfa Electrical Safety & Controls Co., Ltd. Maximum current: 100A rated Number of poles: 2P, 4P Residual current tripping type: No code: AC type, A-A type. Dimensions (mm) 33
38 UELM-100(H) SERIES ELECTRO-MAGNETIC RCCB Products selection table UELM-100 series Pole no. 2P AC type A type Rated current UELM-100 2P 25/30 UELM-100 2P 25/A30 25A UELM-100 2P 32/30 UELM-100 2P 32/A30 32A UELM-100 2P 40/30 UELM-100 2P 40/A30 40A UELM-100 2P 50/30 UELM-100 2P 50/A30 50A UELM-100 2P 63/30 UELM-100 2P 63/A30 63A UELM-100 2P 80/30 UELM-100 2P 80/A30 80A UELM-100 2P 100/30 UELM-100 2P 100/A30 100A UELM-100 2P 25/100 UELM-100 2P 25/A100 25A UELM-100 2P 32/100 UELM-100 2P 32/A100 32A UELM-100 2P 40/100 UELM-100 2P 40/A100 40A UELM-100 2P 50/100 UELM-100 2P 50/A100 50A UELM-100 2P 63/100 UELM-100 2P 63/A100 63A UELM-100 2P 80/100 UELM-100 2P 80/A100 80A UELM-100 2P UELM-100 2P 100/A A 100/100 UELM-100 2P 25/300 UELM-100 2P 25/A300 25A UELM-100 2P 32/300 UELM-100 2P 32/A300 32A UELM-100 2P 40/300 UELM-100 2P 40/A300 40A UELM-100 2P 50/300 UELM-100 2P 50/A300 50A UELM-100 2P 63/300 UELM-100 2P 63/A300 63A UELM-100 2P 80/300 UELM-100 2P 80/A300 80A UELM-100 2P UELM-100 2P 100/A A 100/300 Residual operational current 30mA 100mA 300mA Current limited short circuit current 6kA 34
39 UELM-100(H) SERIES ELECTRO-MAGNETIC RCCB UELM-100 series Pole no. 4P AC type A type Rated current UELM-100 4P 25/30 UELM-100 4P 25/A30 25A UELM-100 4P 32/30 UELM-100 4P 32/A30 32A UELM-100 4P 40/30 UELM-100 4P 40/A30 40A UELM-100 4P 50/30 UELM-100 4P 50/A30 50A UELM-100 4P 63/30 UELM-100 4P 63/A30 63A UELM-100 4P 80/30 UELM-100 4P 80/A30 80A UELM-100 4P 100/30 UELM-100 4P 100/A30 100A UELM-100 4P 25/100 UELM-100 4P 25/A100 25A UELM-100 4P 32/100 UELM-100 4P 32/A100 32A UELM-100 4P 40/100 UELM-100 4P 40/A100 40A UELM-100 4P 50/100 UELM-100 4P 50/A100 50A UELM-100 4P 63/100 UELM-100 4P 63/A100 63A UELM-100 4P 80/100 UELM-100 4P 80/A100 80A UELM-100 4P UELM-100 4P 100/A A 100/100 UELM-100 4P 25/300 UELM-100 4P 25/A300 25A UELM-100 4P 32/300 UELM-100 4P 32/A300 32A UELM-100 4P 40/300 UELM-100 4P 40/A300 40A UELM-100 4P 50/300 UELM-100 4P 50/A300 50A UELM-100 4P 63/300 UELM-100 4P 63/A300 63A UELM-100 4P 80/300 UELM-100 4P 80/A300 80A UELM-100 4P UELM-100 4P 100/A A 100/300 Residual operational current 30mA 100mA 300mA Current limited short circuit current 10kA 35
40 UELM-100(H) SERIES ELECTRO-MAGNETIC RCCB UELM-100 H series Pole no. 2P AC type A type Rated current UELM-100H 2P 25/30 UELM-100H 2P 25/A30 25A UELM-100H 2P 32/30 UELM-100H 2P 32/A30 32A UELM-100H 2P 40/30 UELM-100H2P 40/A30 40A UELM-100H 2P 50/30 UELM-100H 2P 50/A30 50A UELM-100H 2P 63/30 UELM-100H 2P 63/A30 63A UELM-100H 2P 80/30 UELM-100H 2P 80/A30 80A UELM-100H 2P 100/30 UELM-100H 2P 100/A30 100A UELM-100H 2P 25/100 UELM-100H 2P 25/A100 25A UELM-100H 2P 32/100 UELM-100H 2P 32/A100 32A UELM-100H 2P 40/100 UELM-100H 2P 40/A100 40A UELM-100H 2P 50/100 UELM-100H 2P 50/A100 50A UELM-100H 2P 63/100 UELM-100H 2P 63/A100 63A UELM-100H 2P 80/100 UELM-100H 2P 80/A100 80A UELM-100H 2P 100/100 UELM-100H 2P 100A 100/A100 UELM-100H 2P 25/300 UELM-100H 2P 25/A300 25A UELM-100H 2P 32/300 UELM-100H 2P 32/A300 32A UELM-100H 2P 40/300 UELM-100H 2P 40/A300 40A UELM-100H 2P 50/300 UELM-100H 2P 50/A300 50A UELM-100H 2P 63/300 UELM-100H 2P 63/A300 63A UELM-100H 2P 80/300 UELM-100H 2P 80/A300 80A UELM-100H 2P 100/300 UELM-100H 2P 100A 100/A300 Residual operational current 30mA 100mA 300mA Current limited short circuit current 10kA 36
41 UELM-100(H) SERIES ELECTRO-MAGNETIC RCCB UELM-100 H series Pole no. 4P AC type A type Rated current UELM-100H 4P 25/30 UELM-100H 4P 25/A30 25A UELM-100H 4P 32/30 UELM-100H 4P 32/A30 32A UELM-100H 4P 40/30 UELM-100H 4P 40/A30 40A UELM-100H 4P 50/30 UELM-100H 4P 50/A30 50A UELM-100H 4P 63/30 UELM-100H 4P 63/A30 63A UELM-100H 4P 80/30 UELM-100H 4P 80/A30 80A UELM-100H 4P 100/30 UELM-100H 4P 100/A30 100A UELM-100H 4P 25/100 UELM-100H 4P 25/A100 25A UELM-100H 4P 32/100 UELM-100H 4P 32/A100 32A UELM-100H 4P 40/100 UELM-100H 4P 40/A100 40A UELM-100H 4P 50/100 UELM-100H 4P 50/A100 50A UELM-100H 4P 63/100 UELM-100H 4P 63/A100 63A UELM-100H 4P 80/100 UELM-100H 4P 80/A100 80A UELM-100H 4P 100/100 UELM-100H 4P 100A 100/A100 UELM-100H 4P 25/300 UELM-100H 4P 25/A300 25A UELM-100H 4P 32/300 UELM-100H 4P 32/A300 32A UELM-100H 4P 40/300 UELM-100H 4P 40/A300 40A UELM-100H 4P 50/300 UELM-100H 4P 50/A300 50A UELM-100H 4P 63/300 UELM-100H 4P 63/A300 63A UELM-100H 4P 80/300 UELM-100H 4P 80/A300 80A UELM-100H 4P 100/300 UELM-100H 4P 100A 100/A300 Residual operational current 30mA 100mA 300mA Current limited short circuit current 10kA 37
42 UEBL-63(H) SERIES RCBO UEBL-63(H) SERIES RCBO UEBL-63 (H) series residual current circuit breaker with overload protection (RCBO) mainly used in the circuit of AC 50/60Hz, rated voltage under 400V, rated current under 63A, to protect the circuit and electric equipments of building and the similar places from over current, as well as providing the protection once the over current equipment fault and the fire risk due to the ground current fault it s also applicable for the infrequent opening and closing operation. Technical parameter Type UEBL-63 UEBL-63H Standard IEC Number of poles 1P+N, 2P, 3P, 3P+N, 4P Tripping type Electrical type Tripping characteristic C,D Interruptive capacity Icu 6kA 10kA Rated current In 1A~63A Rated voltage 230V/400V Residual operating current ma 30mA Frequency Hz Mechanical life (cycles) Electrical life (cycles) Rated insulation Ui 500V Rated impulse withstand voltage (1.2/50)Uimp 6 000V Power-frequency dielectric strength 2kV Protection class Terminal IP20 Other parts IP40 Ambient temperature Operation temp. -5~+55 Storage temp. -25~70 Humidity Constant humidity 23/83,40/93,55/20 Relative humidity 25/95,40/95 Wiring mm Torque Nm
43 UEBL-63(H) SERIES RCBO Type Designation Breaking Capacity: Rated Current: Products: Circuit breaker Maximum rated current H for 10kA, no code for 6kA 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A UE B - L 63 (H) C 16 / 1P+N Manufacturer code: Electrical residual Tripping characteristic: Number of poles: Xiamen Hongfa Electrical current protection Type C, D 1P+N, 2P, 3P, Safety & Controls Co., Ltd. 3P+N, 4P Products features It s of the all features of UEB-63 (H) series MCB; Overload, short circuit and residual current protection; Protect the human from the indirect contact; Provide the supplementary protection from the direct contact; Provide the protection on insulation failure of electric equipment(such as electric fire); Manual control: handle allows two kinds of reset mode Circuit breakers and residual current operated devices reset at the same time Circuit breakers and residual current operated devices resetindividually, residual current operated device resets before the circuit breaker resets. Prevent transient overvoltage (Lightening, state grid operation) caused by the malfunction. 39
44 UEBL-63(H) SERIES RCBO Dimensions(mm) 40
45 UEBL-63(H) SERIES RCBO Products selection table UEBL-63 Series Number of poles Type C Type D Rated current Breaking capaciy UEBL-63 C6/1P+N UEBL-63 D6/1P+N 6A UEBL-63 C10/1P+N UEBL-63 D10/1P+N 10A 1P+N 2P 3P 3P+N 4P UEBL-63 C16/1P+N UEBL-63 D16/1P+N 16A UEBL-63 C20/1P+N UEBL-63 D20/1P+N 20A UEBL-63 C25/1P+N UEBL-63 D25/1P+N 25A UEBL-63 C32/1P+N UEBL-63 D32/1P+N 32A UEBL-63 C40/1P+N UEBL-63 D40/1P+N 40A UEBL-63 C50/1P+N UEBL-63 D50/1P+N 50A UEBL-63 C63/1P+N UEBL-63 D63/1P+N 63A UEBL-63 C6/2P UEBL-63 D6/2P 6A UEBL-63 C10/2P UEBL-63 D10/2P 10A UEBL-63 C16/2P UEBL-63 D16/2P 16A UEBL-63 C20/2P UEBL-63 D20/2P 20A UEBL-63 C25/2P UEBL-63 D25/2P 25A UEBL-63 C32/2P UEBL-63 D32/2P 32A UEBL-63 C40/2P UEBL-63 D40/2P 40A UEBL-63 C50/2P UEBL-63 D50/2P 50A UEBL-63 C63/2P UEBL-63 D63/2P 63A UEBL-63 C6/3P UEBL-63 D6/3P 6A UEBL-63 C10/3P UEBL-63 D10/3P 10A UEBL-63 C16/3P UEBL-63 D16/3P 16A UEBL-63 C20/3P UEBL-63 D20/3P 20A UEBL-63 C25/3P UEBL-63 D25/3P 25A UEBL-63 C32/3P UEBL-63 D32/3P 32A UEBL-63 C40/3P UEBL-63 D40/3P 40A UEBL-63 C50/3P UEBL-63 D50/3P 50A UEBL-63 C63/3P UEBL-63 D63/3P 63A UEBL-63 C6/3P+N UEBL-63 D6/3P+N 6A UEBL-63 C10/3P+N UEBL-63 D10/3P+N 10A UEBL-63 C16/3P+N UEBL-63 D16/3P+N 16A UEBL-63 C20/3P+N UEBL-63 D20/3P+N 20A UEBL-63 C25/3P+N UEBL-63 D25/3P+N 25A UEBL-63 C32/3P+N UEBL-63 D32/3P+N 32A UEBL-63 C40/3P+N UEBL-63 D40/3P+N 40A UEBL-63 C50/3P+N UEBL-63 D50/3P+N 50A UEBL-63 C63/3P+N UEBL-63 D63/3P+N 63A UEBL-63 C6/4P UEBL-63 D6/4P 6A UEBL-63 C10/4P UEBL-63 D10/4P 10A UEBL-63 C16/4P UEBL-63 D16/4P 16A UEBL-63 C20/4P UEBL-63 D20/4P 20A UEBL-63 C25/4P UEBL-63 D25/4P 25A UEBL-63 C32/4P UEBL-63 D32/4P 32A UEBL-63 C40/4P UEBL-63 D40/4P 40A UEBL-63 C50/4P UEBL-63 D50/4P 50A UEBL-63 C63/4P UEBL-63 D63/4P 63A 6kA 6kA 6kA 6kA 6kA 41
46 UEBL-63(H) SERIES RCBO UEBL-63H Series Number of poles C Type D type Rated current Breaking capaciy UEBL-63H C6/1P+N UEBL-63H D6/1P+N 6A UEBL-63H C10/1P+N UEBL-63H D10/1P+N 10A 1P+N 2P 3P 3P+N 4P UEBL-63H C16/1P+N UEBL-63H D16/1P+N 16A UEBL-63H C20/1P+N UEBL-63H D20/1P+N 20A UEBL-63H C25/1P+N UEBL-63H D25/1P+N 25A UEBL-63H C32/1P+N UEBL-63H D32/1P+N 32A UEBL-63H C40/1P+N UEBL-63H D40/1P+N 40A UEBL-63H C50/1P+N UEBL-63H D50/1P+N 50A UEBL-63H C63/1P+N UEBL-63H D63/1P+N 63A UEBL-63H C6/2P UEBL-63H D6/2P 6A UEBL-63H C10/2P UEBL-63H D10/2P 10A UEBL-63H C16/2P UEBL-63H D16/2P 16A UEBL-63H C20/2P UEBL-63H D20/2P 20A UEBL-63H C25/2P UEBL-63H D25/2P 25A UEBL-63H C32/2P UEBL-63H D32/2P 32A UEBL-63H C40/2P UEBL-63H D40/2P 40A UEBL-63H C50/2P UEBL-63H D50/2P 50A UEBL-63H C63/2P UEBL-63H D63/2P 63A UEBL-63H C6/3P UEBL-63H D6/3P 6A UEBL-63H C10/3P UEBL-63H D10/3P 10A UEBL-63H C16/3P UEBL-63H D16/3P 16A UEBL-63H C20/3P UEBL-63H D20/3P 20A UEBL-63H C25/3P UEBL-63H D25/3P 25A UEBL-63H C32/3P UEBL-63H D32/3P 32A UEBL-63H C40/3P UEBL-63H D40/3P 40A UEBL-63H C50/3P UEBL-63H D50/3P 50A UEBL-63H C63/3P UEBL-63H D63/3P 63A UEBL-63H C6/3P+N UEBL-63H D6/3P+N 6A UEBL-63H C10/3P+N UEBL-63H D10/3P+N 10A UEBL-63H C16/3P+N UEBL-63H D16/3P+N 16A UEBL-63H C20/3P+N UEBL-63H D20/3P+N 20A UEBL-63H C25/3P+N UEBL-63H D25/3P+N 25A UEBL-63H C32/3P+N UEBL-63H D32/3P+N 32A UEBL-63H C40/3P+N UEBL-63H D40/3P+N 40A UEBL-63H C50/3P+N UEBL-63H D50/3P+N 50A UEBL-63H C63/3P+N UEBL-63H D63/3P+N 63A UEBL-63H C6/4P UEBL-63H D6/4P 6A UEBL-63H C10/4P UEBL-63H D10/4P 10A UEBL-63H C16/4P UEBL-63H D16/4P 16A UEBL-63H C20/4P UEBL-63H D20/4P 20A UEBL-63H C25/4P UEBL-63H D25/4P 25A UEBL-63H C32/4P UEBL-63H D32/4P 32A UEBL-63H C40/4P UEBL-63H D40/4P 40A UEBL-63H C50/4P UEBL-63H D50/4P 50A UEBL-63H C63/4P UEBL-63H D63/4P 63A 10kA 10kA 10kA 10kA 10kA 42
47 UEBL-63(H) SERIES RCBO UEBL-40 series RCBO UEBL-40 series residual current circuit breaker with overload protection (RCBO) mainly used in the circuit of AC 50/60Hz, rated voltage under 230V, rated current under 40A, to protect the circuit and electric equipments of building and the similar places from over current, as well as providing the protection once the over current equipment fault and the fire risk due to the ground current fault it s also applicable for the infrequent opening and closing operation. Technical parameter Type UEBL-40 Standard IEC Number of poles 1P+N Tripping characteristic C, D Tripping type Electrical type Interruptive capacity Icu 8kA Rated current In 6A~40A Rated voltage Un 230V Residual operating current ma 30 Frequency Hz Rated insulation Ui 500V Rated impulse withstand voltage(1.2/50)uimp 6 000V Power-frequency dielectric strength 2kV Mechanical life(cycles) Electrical life (cycles) Leakage life(cycles) Pollution degree 2 Protection class Terminal IP20 Other parts IP40 Ambient temperature Operation temp. -5~+55 Storage temp. -25~70 Humidity Constant humidity 23/83,40/93,55/20 Relative humidity 25/95,40/95 Wiring mm Torque Nm
48 Type and meaning Products: Circuit breaker Maximum rated current Rated Current: 6A, 10A, 16A, 20A, 25A, 32A, 40A UE B - L 40 V 16 Manufacturer code: Xiamen Hongfa Electrical Safety & Controls Co., Ltd. Electrical residual Current protection Tripping characteristic: Type C, D 44
49 UEBL-40 SERIES RCBO Products features Module products, save the width up to 50%; Overload, short circuit and residual current protection; Protect the human from the indirect contact; Provide the supplementary protection from the direct contact; Provide the protection on insulation failure of electric equipment(such as electric fire); Manual control: handle allows two kinds of reset mode Circuit breakers and residual current operated devices reset at the same time Circuit breakers and residual current operated devices reset individually, residual current operated device resets before the circuit breaker resets. Prevent transient overvoltage (Lightening, state grid operation) caused by the malfunction. Dimension(mm) Products selection table UEBL-40 Series Number of poles C Type D type Rated current Breaking capaciy UEBL-40 C6 UEBL-40 D6 6A UEBL-40 C10 UEBL-40 D10 10A 1P+N UEBL-40 C16 UEBL-40 D16 16A (N Poles) UEBL-40 C20 UEBL-40 D20 20A 8kA UEBL-40 C25 UEBL-40 D25 25A UEBL-40 C32 UEBL-40 D32 32A UEBL-40 C40 UEBL-40 D40 40A 45
50 UEB-100 SERIES MINIATURE CIRCUIT BREAKER UEB-100 SERIES MINIATURE CIRCUIT BREAKER Products features Overload and short circuit protection; Use Silver graphite material, high breaking capacity, long electrical life; Use the safe wiring structure against the electrical shock; The shelf and the parts use the imported high flame and stamping resistance plastic Module structure for free combination; TH35 standard DIN rail installation; Suitable for disconnecting, symbol is. Main specification Rated voltage: AC230 / 400V; Rated current: 63A, 80A, 100A; Instantaneous tripping characteristic Type C: 5~10In, Breaking capacity: 6kA Number of poles: 1P, 2P, 3P, 4P 46
51 UEB-100 SERIES MINIATURE CIRCUIT BREAKER Type and meaning Miniature Circuit breaker Instantaneous tripping characteristic: Type C: 5-10In Number of poles 1P,2P,3P,4P UE B C 口 / 口 Manufacturer code: Xiamen Hongfa Electrical Safety & Controls Co., Ltd. Maximum rated current Rated Current: : 63,80,100 Products selection table Number of poles Type Rated current(a) Width(mm) XMB0-100 C63/1P 63 1P 2P 3P 4P XMB0-100 C80/1P 80 XMB0-100 C100/1P 100 XMB0-100 C63/2P 63 XMB0-100 C80/2P 80 XMB0-100 C100/2P 100 XMB0-100 C63/3P 63 XMB0-100 C80/3P 80 XMB0-100 C100/3P 100 XMB0-100 C63/4P 63 XMB0-100 C80/4P 80 XMB0-100 C100/4P
52 UEB-63(100) SMART METERS DEDICATED MINIATURE CIRCUIT BREAKERS UEB-63(100) SMART METERS DEDICATED MINIATURE CIRCUIT BREAKERS Feature Excellent current-limiting characteristics: superior to IEC60898 standard specifies three current limiting requirements The good performance of selective protection: breaking the fast ( 3ms) High Breaking Capacity: up to 10kA High reliability and immunity: products through rigorous electromagnetic compatibility (EMC) Test, test standards the GB Appendix F. High life: up to 10 years or more, the whole life of the product and the mechanical life of up to 20,000 times. Loss of pressure trip function (optional): less than 65% of the rated voltage control voltage not Allowing the main circuit is closed, to prevent the forced closing behavior. Isolation instructions (optional): contact position indicator and handle instructions. Main parameters and technical performance UEB-63(H)N Seires Rated working voltage Un (V): 230 (1P + N), 400 (3P + N); Releasing characteristics: C-type, tripping current 5In to 10In; Rated working current In (A): 6,10, 16,20,25,32,40,50,63; Rated control voltage Us (V): 230; Delay time of intelligent shunt release of circuit breaker :1 ~~ 2s; Rated short circuit breaking capacity Ics (A): UEB-63N: 6000, UEB-63HN: 10000; Dielectric strength: circuit breakers can withstand AC 50/60Hz,high voltage of 2000V within 1min without breakdown or flashover. Mechanical electrical life: mechanical life: Electrical Life: The shunt trip life:
53 UEB-63(100) SMART METERS DEDICATED MINIATURE CIRCUIT BREAKERS UEB-100N seires Rated working voltage Un (V): 230 (1P + N), 400 (3P + N); Releasing characteristics: C-type, tripping current 5In to 10In; Rated working current In (A): 63,80,100; Rated control voltage Us (V): 230; Delay time of intelligent shunt release of circuit breaker :1 ~~ 2s; Rated short circuit breaking capacity Ics (A): 6000; Dielectric strength: circuit breakers can withstand AC 50/60Hz, 2000V high voltage 1min without breakdown or flashover. Mechanical electrical life: mechanical life: Electrical Life: he shunt releasing life: 4000 Type and meaning Miniature Circuit breaker Frame rating AF Smart meters dedicated miniature circuit breakers Rated current: UE B - 63 (H) N 口口 / 口 Manufacturer code: Xiamen Hongfa Electrical Safety & Controls Co., Ltd. Breaking capacity: H: 10 ka NO Code: 6kA Instantaneous Tripping characteristic Number of poles: 1P+N 3P+N 49
54 UEB-63(100) SMART METERS DEDICATED MINIATURE CIRCUIT BREAKERS Products selection table UEB-63N series Pole number Type C Rated current Breaking capacity UEB-63N C6/1P+N 6A UEB-63N C10/1P+N 10A UEB-63N C16/1P+N 16A 1P+N UEB-63N C20/1P+N 20A UEB-63N C25/1P+N 25A 6kA UEB-63N C32/1P+N 32A UEB-63N C40/1P+N 40A UEB-63N C50/1P+N 50A UEB-63N C63/1P+N 63A UEB-63N C6/3P+N 6A UEB-63N C10/3P+N 10A UEB-63N C16/3P+N 16A 3P+N UEB-63N C20/3P+N 20A UEB-63N C25/3P+N 25A 6kA UEB-63N C32/3P+N 32A UEB-63N C40/3P+N 40A UEB-63N C50/3P+N 50A UEB-63N C63/3P+N 63A 50
55 UEB-63(100) SMART METERS DEDICATED MINIATURE CIRCUIT BREAKERS Products selection table UEB-63HN series Pole numbers Type C Rated current Breaking ability UEB-63HN C6/1P+N 6A UEB-63HN C10/1P+N 10A UEB-63HN C16/1P+N 16A 1P+N UEB-63HN C20/1P+N 20A UEB-63HN C25/1P+N 25A 10kA UEB-63HN C32/1P+N 32A UEB-63HN C40/1P+N 40A UEB-63HN C50/1P+N 50A UEB-63HN C63/1P+N 63A UEB-63HN C6/3P+N 6A UEB-63HN C10/3P+N 10A UEB-63HN C16/3P+N 16A 3P+N UEB-63HN C20/3P+N 20A UEB-63HN C25/3P+N 25A 10kA UEB-63HN C32/3P+N 32A UEB-63HN C40/3P+N 40A UEB-63HN C50/3P+N 50A UEB-63HN C63/3P+N 63A UEB-100N series Pole numbers Type C Rated current Breaking ability 1P+N UEB-100N C63/1P+N 63A UEB-100N C80/1P+N 80A 6kA UEB-100N C100/1P+N 100A 3P+N UEB-100N C63/3P+N 63A UEB-100N C80/3P+N 80A 6kA UEB-100N C100/3P+N 100A 51
56 UES5 SERIES SUPGE PROTECTIVE DEVICE UES5 SERIES SUPGE PROTECTIVE DEVICE Products feature UES5 series surge protective decvice (SPD for short), which conforms to standards IEC ,GB , and is applicable to various power supply systems of AC 50Hz/60Hz and rated voltage 380V. The product has a lapsing-divorcement device and a reliable operating status indication, and the function of remote communicated contact is available to achieve long-distance control; the response time is less than 25 nanoseconds, and the product adopts 35mm electrical rail with safe use and easy installation. Type and meaning Protection class B,C,D Number of poles 1P,2P,3P,4P, 1+NPE,2+NPE, Rated working current: 140,275,320, 385,420,690,1000 X:With remote signal contact, otherwise, without X 3+NPE UES5 - C/ PV - X Manufacturer code: Xiamen Hongfa Electrical Safety & Controls Co., Ltd. (Manufacturer s code) Max. discharge current Imax:10-200kA PV:For the DC PV system. witout PV: Applying to AC system 52
INTELLIGENT AIR CIRCUIT BREAKER
UEW5 SERIES INTELLIGENT AIR CIRCUIT BREAKER UEW5 Series intelligent Air Circuit Breaker(ACB) is applicable for the power distribution circuit under the condition of AC50HZ, rated working voltage 400V or
More informationUEW5 series intelligent air circuit breaker
UEW5 series intelligent air circuit breaker UEW5 series intelligent air circuit breakers are applicable to the power distribution circuit under the condition of AC50Hz/60Hz, rated working voltage 400V
More informationcor Long Run Experience
Moulded Case Circuit Breakers Moulded Case Circuit Breakers 16-1250A cor Long Run Experience cor Breaking capacity (according to IEC 947-2 at 415V) Icu 100 D160L D250L D400L D630L 70 60 DH800 50 35 30
More informationand other modular devices for low voltage installation
Technical catalogue System and other modular devices for low voltage installation 2CSC400002D0204 SUMMARY Introduction Miniature Circuit-Breakers Residual Current Devices Auxiliary elements and accessories
More informationNDM3 Series. Molded Case Circuit Breaker. Shanghai Liangxin Electrical CO., LTD.
Shanghai Liangxin Electrical CO., LTD. - Liangxin Electrical - All rights reserved Address: No. 66 eng An Road, Pu Dong New District, Shanghai Post code: 07 Tel: 6--479 Fax: 6--5675966 E-mail: client@sh-liangxin.com
More informationSpecification for 70mm pole pitch Air circuit breaker up to 1600 A
Specification for 70mm pole pitch Air circuit breaker up to 1600 A Protective device for low voltage electrical installation Last update :2011-07-08-1 - Table of contents: 1 General...3 2 Compliance with
More informationGJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector
GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................
More informationDPX moulded case circuit breakers
BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.
More informationNDM1 Series MCB Edition
NDM1 Series MCB 2016 Edition COMPANY PROFILE Shanghai Liangxin Electrical Co., LTD. one of the leading low-voltage electrical component manufacture in the high-end market, was established in 1999. Nader
More informationatalog Welcome to ATO.com! Contact us... Tel: (Toll-free) Website:
atalog Welcome to.com! Contact us... Email: sales@ato.com Tel: +1 800-585-1519 (Toll-free) Website: ZMQ2E Series Dual Power Automatic Transfer Switch (ATS) Applications ZMQ2E dual auto transfer switch
More informationInstantaneous tripping TYPE B, C, D TYPE B, C TYPE B, C, D TYPE B, C IEC RCCB TYPE C IEC61008 RCBO 25, 40, 63A. IEC61009 Isolating Switch
Features (1) All models fully comply with IEC regulations (2) Units can be mounted on a standard 35mm IEC rail (3) Residual current circuit breakers use an original Mitsubishi Electric IC securing reliable
More informationPage. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases
Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar
More informationschneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric.
K0 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads Overview K0 Circuit Breaker Technical Specification MCB RCCB K0 Circuit Breaker K0N K0H ID K Number of poles
More informationDX³ 4-pole RCBO 6000 A/10 ka
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ 4-pole RCBO CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More information01 Spectra Plus - Introduction
01 Spectra Plus - Introduction Standard features Conforming to IS13947-2/EN60947 2 Compact dimensions Available in 3P & 4P High performance microprocessor protection release Wide overload setting from
More informationDX³ RCBO 4500/6 ka Phase + Neutral, neutral on left
87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX³ RCBO 4500/6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection...
More informationMINIATURE CIRCUIT BREAKER
Technical Article MINIATURE CIRCUIT BREAKER T 146 PURCHASE he Spaceage MCB protects wires and cables automatically against overload and short-circuits in domestic, commercial and industrial installations.
More informationEKM1-63S MCB Mini Circuit Breaker
EKM1-63S MCB Mini Circuit Breaker Standard: IEC60898-1 Rated current In :1,,3,4,6,10,13,16,0,5,3,40,,63A Poles:1P, 1P+N, P, 3P, 3P+N,4P Rated voltage Ue:40/415V Insulation voltage Ui :0V Rated frequency:/60hz
More informationIndustrial Protection Products Edition
Industrial Protection Products 2016 Edition COMPANY PROFILE Shanghai Liangxin Electrical Co., LTD. one of the leading low-voltage electrical component manufacture in the high-end market, was established
More informationDPX Magnetic only
87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 5. CONFORMITY
More informationLow Voltage A GE Power Controls Company. General catalogue
Low Voltage A GE Power Controls Company General catalogue this is a blanc page Miniature circuit breakers A Miniature circuit breakers AC miniature circuit breakers Benefits of the new MCB s A 3 The AEG
More informationKM1 Series Moulded Case Circuit Breaker
KM1 KM1 Series Moulded Case Circuit Breaker 1. Application KM1 series moulded case circuit breaker is one of products developed and manufactured by adopting international advanced technology. It is supplied
More informationOffers. QOvs RCBO residual current devices. Protection Earth leakage protection. Variants
devices Offers This page must be removed before publishing The Schneider Electric residual current devices range comprises various offers (A, B, C, D) so as to be as competitive as possible in each country,
More informationMiniature Circuit Breaker
Introduction - Miniature Circuit Breaker (MCB) SALIENT FEATURES SALIENT FEATURES Standards MCBs conform to the latest standard IS 8828: 1996/IEC: 898 1995 Mid-Trip Position The Mid trip position of the
More informationGet detailed information on many digital or printed supports, or contact your Area Commercial Manager
The RX 3 and DX-E ranges provide essential functions for the protection requirements of people and property in residential and small commercial buildings Two breaking capacities, 4500 and 6000 (IEC 60898-1)
More informationBtdin RCBO 6000A up to 63A (2P)
Index Pages 1. Descripton... 2 2. Product range... 2 3. Overall dimensions... 2 4. Fixing Connection... 3 5. Generl characteristics.... 4-29 6. Compliance - Approvals... 30 7. Curves... 30-34 8.Auxiliaries-
More informationCat N 3. OVERALL DIMENSIONS
Cat N Motor driven remote control module 87045 LIMOGES Cedex - FRANCE Telephone : + 33 5 55 06 87 87 Fax: + 33 5 55 06 88 88 Cat N : : 4 062 91 CONTENTS PAGE 1. Description - Use...1 2. Product range...1
More informationCharacteristics of LV circuit breakers Releases, tripping curves, and limitation
Characteristics of LV circuit breakers Releases, tripping curves, and limitation Make, Withstand & Break Currents A circuit breaker is both a circuit-breaking device that can make, withstand and break
More informationDPX earth leakage DPX 3 -I earth leakage
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 + earth leakage Reference(s) : 420 225/ 227/ 228/229/ 255/ 257/ 258/ 259/ 285/ 287/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3.
More informationDS201 - DS202C New residual current circuit-breakers with overcurrent protection (RCBOs)
DS201 - DS202C New residual circuit-breakers with over protection (RCBOs) New residual circuit-breakers with over protection (RCBOs) - DS201 - DS202C 1P+N and 2P in two modules. Complete protection To
More informationMulti 9 TM. Catalogue 2017 Multistandard protection for OEM. schneider-electric.com
Multi 9 TM Catalogue 207 Multistandard protection for OEM schneider-electric.com Green Premium TM Endorsing industry eco-friendly products Schneider Electric s Green Premium ecolabel is committed to offering
More informationResidual Current Protective Devices / Arc Fault Detection Devices (AFDDs)
Introduction Overview Devices Page Application Standards Used in / Personnel, material and fire protection, as well as protection against direct contact. SIGRES with active condensation protection for
More informationDPX Thermal magnetic and trip-free switches DPX 3 -I 250
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 Reference(s) : 420 205/ 207/ 208/209/ 215/ 217/ 218/ 219/ 235/ 237/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.
More informationThe effective choice The benefits of a product with the highest quality standards
The effective choice The benefits of a product with the highest quality standards Compact size for easy installation in small spaces and retrofitting of already existing facilities. Terminals designed
More informationMM5 Series High Breaking Mini Circuit Breakers
MM5 Series High reaking Mini ircuit reakers M Series A Series M Series ATS Series Load-isolating Series ontrol Appliance Series Product overview MM5 mini circuit breaker has novel structure, reliable performance,
More informationDX³ RCBO 6000 A Phase + Neutral, neutral right side
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX³ RCBO 6000 A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection... 1
More informationRESIDUAL CURRENT CIRCUIT BREAKER
Quality Features Mid Trip - Different knob position to indicate whether the device is Switched OFF by a fault or Switched OFF manually Inscription Window - Ensures circuit identification and hence reduces
More informationCircuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63
Functions and characteristics Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63 NT and NW selection criteria Masterpact NT Masterpact NW NT06, NT08, NT10, NT12, NT16 NT06, NT08, NT10
More informationLEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 LEXIC MCB s DX-H 80A, 100A, 125A Curv urves B and C CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1
More informationDNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DNX 3 MCB 4500 A / 6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation
More informationPower systems Protection course
Al-Balqa Applied University Power systems Protection course Department of Electrical Energy Engineering Dr.Audih 1 Part 3 Protective Devices Fuses & Circuit Breakers 2 Introduction: Fuse Is advice used
More informationProtection components
Presentation, characteristics Presentation 1 2 3 motor circuit-breakers are 3-pole thermal-magnetic circuit-breakers standards IEC 60947-2 and IEC 60947-4-1. Connection These circuit-breakers are designed
More informationCat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. .
87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s 0090 00/01/02/06/07/11/12/13/14 0/01/02/06/07/11/12/13/14/18/19/23/24/25/26/ /18/19/23/24/25/26/45/46 45/46 0090
More informationCDM1. Standard: IEC Technical data. current A 3P,4P Rated frequency Hz V. voltage Ui V. withstand voltage Uimp V.
Function CDM1 molded case circuit breakers can be used to provide the following functions: To distribute electric power and protect circuits and equipment against overload, undervoltage, and short-circuit
More informationNew DMX 3. Efficient protection up to A AIR CIRCUIT BREAKERS PRODUCT GUIDE
New DMX 3 Efficient protection up to 4 000 A AIR CIRCUIT BREAKERS PRODUCT GUIDE NEW DMX 3 ACBs UP TO 4 000 A EFFICIENT PROTECTION AND CONTROL FOR ALL TYPE OF BUILDINGS 02 Electrical panel equipped with
More informationDPX Thermal magnetic and trip-free switches DPX 3 -I 630
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 2 6. CONFORMITY
More informationNB1 Miniature Circuit Breaker
P-00 Modular DIN Rail Products MCB NB Miniature Circuit Breaker Color coded contact position indicator provides visual indication of the device status and insulation function Magnetic trip elements provide
More informationRange 16A to 63A. Sensitivity 30mA, 100mA, 300mA, 500mA. Execution Double Pole, Four Pole. Specification IEC / IS : 2000
The flow of current through electrical facilities always involves risks. Poorly insulated equipment, faulty wires and incorrect use of an electrical devise cause currents to flow through the wrong path
More information15 16 MCCBs for Power Distribution Technical Specification Frame 100A 250A 250A 400A 400A 630A 800 / 1000 / 1250 Type C DN0-100 D DN1-250 N DN2-250 D N S H DN3B-400 DN3-400 D N D N S V DN3-630 DN4-1250
More informationMCBs and RCDs LR TM 6000
MCBs and RCDs LR TM 6000 thermal magnetic MCBs from 6 A to 63 A B and C curves residual current devices from 25 A to 63 A AC and A types ± ± ± ± MCBs Single pole 230/400 V± Single pole neutral 230 V± (1)
More informationPhase + Neutral, neutral on right side
87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX 3 MCB 6000 A / 10 ka Cat.. N (s): 4 074 67 / 68 / 69 / 70 / 71 / 72 / 73 / 74 / 75 / 76 / 77 / 78 / 79 ; 4 077 33 / 34
More informationDPX 1600 Electronic release
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 1600 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND
More informationPhase + Neutral, neutral on left side
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGE 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1
More informationDSE201 Compact design with enhanced protection
DSE201 Compact design with enhanced protection The best of safety DSE201 6 ka: the highest level of reliability The 1P+N electronic residual current circuit-breakers with overcurrent protection (RCBOs)
More information6300A 15 Optibreak B1 & B2 Optibreak B1 & B2 50/60 Hz Ue Icu [v] [ka] 415 65 690 40 4h 4i 1. Open / close Indication 2. Charge and Discharge Indicator 3. Release the reset button 4. Laser Nameplate
More informationic60a circuit breakers (curve C)
(curve ) DB9 DB98 DB99 DB88 IE/EN 097- IE/EN 0898- ountry approval pictograms PB09-0 PB09-0 bb are multi-standard circuit breakers which combine the following functions: vvcircuit protection against short-circuit
More informationDX 3 MCBs. Choice of DX 3 MCBs for capacitor banks. Technical data
Specifications IS/IEC 60898-1 2002 Number of poles SP, SPN, DP, TP, TPN, FP Characteristics C & D Curve Breaking capacity 10 ka 0.5 A to 63 A as per IS/IEC 60898-1 2002 16 ka for 0.5 A to 25 A as per IEC
More informationCircuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases
Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters
More informationTX³ RCCBs 2P up to 100 A
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 TX³ RCCBs CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationDZ47LE C45LE Residual Current Circuit Breaker with Over Current Protection
DZ47LE 1P+ DZ47LE C45LE Residual Current Circuit Breaker with Over Current Protection DZ47LE C45LE RCBO is used for the protection against electrical leakage in the circuit of 50Hz or 60Hz, rated voltage
More informationC60H-DC. C curve IEC Direct current (DC) Breaking capacity (Icu) according to IEC Type 1P 110 V 220 V 250 V 440 V 500 V
DC circuit supplementary protectors for feeders / distribution systems C60H-DC C curve DB123430 DB123525 DB405571 IEC 60947-2 PB107193-34.eps PB107194-34.eps The C60H-DC supplementary protectors are used
More informationABB STOTZ-KONTAKT GmbH
ABB STOTZ-KONTAKT GmbH MULTIPLE 89 Motijheel C/A, Lucky Chamber (3rd floor, Room #61), Dhaka-1000, Bangladesh. Tel: (02) 9559692, Fax: (02)9566596 E-mail: info@multipletrading.net PAGE : 02 The ABB Line
More information3 - Protection components Motor circuit-breakers
Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page
More informationRX 3 M.C.B A up to 63 A
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 RX 3 M.C.B. 6000 A up to 63 A Cat. N (s): 4 197 49 to 4 199 23 CONTENTS PAGES 1. Description, use... 1 2. Range... 1 3. Overall dimensions...
More informationNew DX 3 High rating & breaking capacity
New High rating & breaking capacity a new range OF MOduLar CirCuiT BrEakErs up TO 125 a T new dx³ MCBs AN ENHANCED range for HIgH-pErforMANCE INstALLAtIoNs DX³ : the new Legrand MCBs with dx³, Legrand
More informationDX³ RCBO 6000 / 10 ka Phase + Neutral, neutral on left
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX³ RCBO 6000 / 10 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection...
More informationDX³ RCBO 6000A Phase + Neutral, neutral on left
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ RCBO 6000A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection...
More informationC 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers
SPETRONI SP - Air circuit breakers Summary 2. General characteristics 3. Fixed circuit breaker 4. Withdrawable circuit breakers 5. haracteristics 6. RV23: protection and control unit 6. RV+ : protection
More informationDPX Thermal magnetic and trip-free switches DPX 3 -I 160
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 6. CONFORMITY
More information87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS
87045 LIMOGES Cedex Phone : + 33 5 55 06 87 87 Fax : + 33 5 55 06 88 88 R.C.B.O. DX 6000 A Phase + Neutral,, neutral on right side Cat. n (s) : 077 31 077 44-077 77 077 84 078 79 079 01-083 95 084 06 084
More informationR.C.B.O. SP / 1 module
87045 LIMOGES Cedex - France Telephone : (+33) 5 55 06 87 87 Fax : (+33) 5 55 06 88 88 R.C.B.O. SP / 1 module 6064 04 6064 64 05 6064 10 6064 11 6064 12 CONTENTS PAGES 1. Description, use... 1 2. Range...
More informationDPX Electronic + earth leakage
87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 DPX 3 250 Electronic + earth leakage CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. ELECTRICAL AND MECHANICAL
More informationMULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers
IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when
More information- Moulded-case Circuit Breaker
Safety Protection Catalogue 2013/2014 - MAXTRIC circuit breaker Working with the world s electric specialist together @ Cat. No. CM1 1. Application CM1 series moulded case circuit breaker is one of products
More informationData sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427
Data sheet CI-TI TM Contactors and Motor Starters Circuit Breakers November 2002 DKACT.PD.C00.L2.02 520B1427 Introduction Circuit breakers/manual motor starters cover the power ranges 0.09-12.5 kw This
More informationCOMPLETE SOLUTIONS FOR POWER PROTECTION
COMPLETE SOLUTIONS FOR POWER PROTECTION GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES Modular protection P. 8 RX 3 MCBs 63 A 4500 & 6000 P. 18 DX 3 -IS isolating switches P. 9 RX
More informationMV Air Insulated Switchgear TAP17. Technical Data TGOOD
MV Air Insulated Switchgear TAP17 Technical Data TGOOD 2017.1 Operating environmental conditions Place of installation: Indoor or outdoor Ambient temperature: 25 ~ +40 (higher or lower temperature optional)
More informationRX 3 M.C.B A up to 63 A
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 RX 3 M.C.B. 6000 A up to 63 A CONTENTS PAGES 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationBtdin-RS RCBO 2p Phase + Neutral, neutral on right
Viale Borri 231, 21100 Varese - Italy RCBO 2p CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection... 1 5. General characteristics... 2 6. Compliance
More informationSoftstarter Intelligent Controllers
Softstarter Intelligent Controllers Series Modes of Operation (Standard) Soft Start 100% Percent Voltage Initial Torque Start Run This method has the most general application. The motor is raised from
More information, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX 3 4500 A / 6 ka CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1
More informationPerfection that Matters
Perfection that Matters Switchgear Range Catalogue 2017 Contents Power Series Distribution Boards Classique Distribution Boards Miniature Circuit Breaker Isolator Residual Current Circuit Breaker Residual
More informationME 07 Air Circuit Breakers. ME 07 - Air Circuit Breakers. Low Voltage. Low Voltage. Low Voltage
Low Voltage ME 07 - Air Circuit Breakers ME 07 Air Circuit Breakers Low Voltage AEG Niederspannungstechnik GmbH & Co KG Berliner Platz 2-6 D-24534 Neumünster (Germany) Tel. +49/43211-0 Fax +49/43211-144
More informationContents. Acti 9 MCBs, RCCB. ic60h circuit breakers (curve B, C, D)... pages 2/2 to 2/4. ic60h and ic60h2 RCB0 10, 30 and 100 ma...
Contents Acti 9 MCBs, RCCB ic60h circuit breakers (curve B, C, D)... pages / to /4 ic60h and ic60h RCB0 10, 30 and 100 ma.... pages /5 to /8 Vigi ic60 add-on residual current devices.... pages /9 to /1
More informationNEW TX³ RANGE PROTECTION YOU CAN RELY ON
TX³ NEW RANGE TRUSTED PROTECTION FOR YOUR INSTALLATIONS GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES NEW TX³ RANGE PROTECTION YOU CAN RELY ON Designed to meet the requirements of
More informationElectronic circuit breaker EBU10-T
Description The electronic circuit protector type EBU10-T (Electronic Breaker Unit) provides selective overcurrent protection in AC 230 V UPS systems. It consists of an MCB approved for short circuit interruptions
More informationQUALITY ASSURANCE & DOCUMENTATION
QUALITY ASSURANCE & DOCUMENTATION RTECK IMPORTED PRODUCT STATEMENT Rteck has sourced most product from a large and reputable Chinese product manufacturer who specialise in the manufacture of modular electrical
More informationBtdin RCD Add-on modules 125A for MCBs 1,5 modules per pole
Index Pages 1. Descripton... 2 2. Product range... 2 3. Overall dimensions... 2 4. Fixing Connection... 3 5. Generl characteristics... 4 6. Compliance - Approvals... 6 7. Curves... 7 8. Auxiliares and
More informationInstantaneous tripping TYPE B, C, D TYPE B, C TYPE B, C, D TYPE B, C IEC RCCB TYPE C IEC61008 RCBO 25, 40, 63A. IEC61009 Isolating Switch
Features () All models fully comply with IEC regulations () Units can be mounted on a standard 5mm IEC rail () Residual current circuit breakers use an original Mitsubishi Electric IC securing reliable
More informationDomae. The right solution for distribution boards
Domae The right solution for distribution boards Guaranteed quality and adapted solutions Domae : SIRIM approved The quality marks prove product conformity to their reference standard. They guarantee:
More informationTechnical catalogue. System pro M. Residual current devices 2CSC420001D0201
Technical catalogue System pro M Residual current devices 2CSC42000D020 SUMMARY Residual current devices Technical details and guide to applications Overall dimensions 2 3 ABB SACE and its commitment to
More informationBREAKER. Molded Case Circuit Breaker/Earth Leakage Circuit Breaker
BREAKER Molded Case Circuit Breaker/Earth Leakage Circuit Breaker 2 BREAKER With an improved technology and agressive invesment in R&D, DAERYUK create differentiated value for each customer in order to
More informationCHINT. NM7 Moulded Case Circuit Breaker
CHINT Moulded Case Circuit Breaker Moulded Case Circuit Breaker Application Product introduction Functions and characteristics Accessories Overall and dimension Specification selection and order Page
More informationIndex. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.
Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv
More information013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS
013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS FOR OVERHEAD NETWOKS CEYLON ELECTRICITY BOARD SRI LANKA Specification for MOULDED CASE CIRCUIT BREAKERS FOR OVERHEAD NETWOKS CEB Specification
More information(1,5 modules per pole)
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 DX 3 MCB 36kA, 80A CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationPrisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter
3 Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter The easy choice for quality, value, and peace of mind Schneider Electric makes it an easy choice
More informationControl Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD
Bulletin Product Selection Open Type and Non-Combination Enclosed (IP, NEMA /) Controllers For use with Line-Connected Motors Rated Voltage [V AC] / Motor Current [A]...... Max. kw, Hz Max. Hp, Hz Control
More informationSystem pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489
System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU 200 M is ABB s solution for UL 489 branch
More informationDRX 125 Circuit breaker (not adjustable)
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 272 20/21/22/23/24/25/26/27/55/56/57/58/59/60 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (continuation) 2 4.