Instantaneous tripping TYPE B, C, D TYPE B, C TYPE B, C, D TYPE B, C IEC RCCB TYPE C IEC61008 RCBO 25, 40, 63A. IEC61009 Isolating Switch

Size: px
Start display at page:

Download "Instantaneous tripping TYPE B, C, D TYPE B, C TYPE B, C, D TYPE B, C IEC RCCB TYPE C IEC61008 RCBO 25, 40, 63A. IEC61009 Isolating Switch"

Transcription

1 Features () All models fully comply with IEC regulations () Units can be mounted on a standard 5mm IEC rail () Residual current circuit breakers use an original Mitsubishi Electric IC securing reliable earthleakage protection () High currentlimiting performance (5) Compliance with IPX protection rating () All models are compatible with reverse connection (7) DC circuitcompatible model (BHD) added to product lineup Product up Model type No of poles (P) Rating Instantaneous tripping Voltage (V) ShortCircuit capacity (ka) Compliance standard BHD,,, (+N) +N 0.5A 0.50A TYPE B, C, D TYPE B, C 0/00AC 0AC IEC088 MCB BHD BHD (For DC),,, (+N) 0.5A 0.5A TYPE B, C, D TYPE B, C 0/00AC 5DC 50DC IEC088 IEC088 BHDN +N 0A TYPE C 0AC.5 IEC088 RCCB BVD (+N), (+N) 5, 0, A 0/00AC IEC08 RCBO BVDN +N 0A TYPE C 0AC.5 IEC0 Isolating Switch KBD,,, (+N),, 80A 0/00AC IEC07 Explanation of Markings (Example Model : BHD) Model type Rated voltage Standard Instantaneous tripping model type and Rated current Shortcircuit capacity Wiring diagram Technical Specifications Ambient temperature range Frequency ~ +0 50/0Hz

2 MINIATURE CIRCUIT BREAKERS,RESIDUAL CURRENT CIRCUIT BREAKERS & ISOLATING SWITCHES DIN Series Points to Note Installation Connection Standard IEC5mm rail installation is possible. Fix by attaching a slip stopper. Fig. Installation. Removal Opening, Closing and Tripping Operations At the time of wire connection, fasten the terminal screws with the torque stated in the table below. Fastening torque Screw diameter M5 M M.5 Fastening torque Nm Model type BHD, BHD, BVD, KBD SHTA0005DLS, SHTD0805DLS BHDN, BVDN AL05DLS, 05DLS, AL05DLS 05DLS Move the handle up/down to turn power On/Off. Tripping operation refers to automatic opening (breaking) of circuits. Earthleakage Test Earthleakage test steps: () Move the handle to the On position under rated voltage. () The handle will move to the Off position. () Push the yellow test button. (5) The earthleakage indication changes from white to red. () At this time, the RCCB or RCBO must be tripped within the specified time. 5 Withstand Voltage Test () () Withstand voltage test: The voltage applied to the main circuit during the withstand voltage test is,000vac (effective for min). Do not conduct a withstand voltage tests using voltages exceeding,000vac. Measurement of insulation resistance and withstand voltage test Please note the following restrictions ( and below) that apply when using earthleakage circuit breakers. Measuring insulation resistance: Do not use a 00V insulation resistance tester. Please use a 500V insulation resistance tester. The marks in the table are based on minimum insulation resistance values. Testing withstand voltage: The X marks in the table below indicate that the test voltage is not to be applied to that model. (If a test voltage is accidently applied to one of these models, do not reuse the product regardless of whether or not they were tripped.) Test Measuring position Handle position Between main circuit live part and ground BVD P BVDN On line side Between right pole (terminal symbol ) and N pole Between BVD P Between poles other than above different BVD P BVDN poles On load side Between right pole (terminal symbol ) and N pole BVD P Between poles other than above Between terminals on line side and load side Insulation resistance measurement ON OFF Withstand voltage test ON OFF Installation of Accessories (, AL, SHT) () Installation () Removal Off Hook Insert Click

3 Specifications BHD BHD BHDN MCB Image No. of poles [P] (+N) (+N) (+N) (+N) Instantaneous tripping B, C, D B, C B, C, D C Rated insulation voltage Ui [V] Rated current In [A] at ambient temperature 0: Rated shortcircuit capacity [ka] IEC088 GB. Number of operating cycles Dimensions [mm] 0.5,,.,,,,,,,, 0, 5,, 0, 50, 0.5,,.,,,,,,,, 0, 5,, 0 0.5,,.,,,,,,,, 0, 5,, 0, 50,,,, 0 AC 0V.5 0/00V 00V Without current 8,000,000 0,000 With current 8,000,000 0,000 a b c ca of overcurrent release Thermalmagnetic Thermalmagnetic Thermalmagnetic Mounting IEC5mm rail IEC5mm rail IEC5mm rail Applicable wire size to 5mm to 5mm to mm Weight [kg] Accessories (optional) a b ca c Alarm switch (AL) Auxiliary switch () Shunt trip (SHT) Terminal connection Solderless Solderless Solderless Based on standard IEC088 IEC088 IEC088 CE marking EN088 : Selfdeclaration EN088 : Selfdeclaration EN088 : Selfdeclaration CCC GB. GB. GB. : N pole is a switched neutral pole (without overcurrent release device). : B: ( In <, 5 In), C: (5 In <, In), D: ( In <, 0 In) For DC BHD Image 5 No. of poles [P] Instantaneous tripping B, C Rated insulation voltage Ui [V] 50 Rated current In [A] at ambient temperature 0: Rated shortcircuit capacity [ka] IEC088 GB. Number of operating cycles Dimensions [mm] of overcurrent release Mounting 0.5,,.,,,,,,,, 0, 5,, 0, 50, DC 5V 50V Without current 8,000 With current,000 a 8 b 87 c ca 70 Thermalmagnetic IEC5mm rail Applicable wire size to 5mm Weight [kg] Accessories (optional) Alarm switch (AL) Auxiliary switch () Shunt trip (SHT) Terminal connection Based on standard CE marking CCC a b ca c : B: (5 In <, 7 In), C: (7 In <, 5 In) Solderless IEC088 EN088 : Selfdeclaration GB.

4 Accessories Functions of Accessories Internal accessory Function AL Alarm switch Electrically indicates the trip status of the circuit breaker. Auxiliary switch SHT Shunt trip Electrically indicates the On/Off status of the circuit breaker. Electrically trips the circuit breaker from a remote location. Permissible working voltages are 70 to % of the AC rated voltage or 70 to 5% of the DC rated voltage. Equipping of Accessories Accessory Model name BHD BHD BHDN, BVDN, KBD, BVD AL SHT : Accessory equipped : Accessory not equipped Specifications AL AL+ + AL05DLS 05DLS AL05DLS 05DLS Contact Function Configuration C C C C Contact capacity 00VAC, A 0VAC, 5A 0VDC, 0.A 8VDC,.5A AL AL Connection Busbar terminal Compliance standard IEC075 GB08.5 SHTA0005DLS SHT SHTD0805DLS Cutoff switch Equipped Voltage 00VAC 8VDC Input power requirement VAC 0VA VDC 75VA 0VAC 50VA 8VDC 00VA 00VAC 750VA Operating time [ms] <0 Connection Solderless terminal Compliance standard IEC07 GB08. * Secure a sufficient input power supply so that the voltage will not drop below the permissible lower working voltage (70% of the lowest rated voltage). * The operating time denotes the time from when the rated voltage is applied to SHT until the time the main contact of the breaker starts to open. 7

5 DIN Series Accessories Combinations of Accessories AL AL Accessory connection combinations SHT +SHT AL+SHT +SHT AL+SHT Breaker AL AL AL+ + SHT Outer Dimensions AL05DLS 05DLS AL05DLS 05DLS SHTA0005DLS SHTD0805DLS AL05DLS Solderless terminal M.5 screw M.5 screw 7 7 M.5 screw 7 8 M5 screw 7 Connection of and Side AL05DLS 05DLS AL05DLS 05DLS c b a c b a 5 ALc 8 5 AL ALb 8 ALa c b a 8 5 AL 5 ALc ALb 8 ALa c b a 8

6 Characteristics and Dimensions Miniature Circuit Breakers BHD BHD BHD No. of poles [P] Instantaneous tripping IEC088 GB. AC (+N) B, C 0.5,,.,,,,,,,, 0, 5,, 0 0.5,,.,,,,,,,, 0, 5,, 0, 50, (+N) B, C, D 0 Rated current In [A] at ambient temperature 0: Rated shortcircuit capacity [ka] (+N) B, C, D Rated insulation voltage Ui [V] BHD (For DC) BHD B, C ,,.,,,,,,,, 0, 5,, 0, 50, 0.5,,.,,,,,,,, 0, 5,, 0, 50, 0V 0/00V 00V IEC088 DC 5V GB. 50V : N pole is a switched neutral pole (without overcurrent release device). noperating Characteristics h h Operating Characteristics : BHD,BH( B,C) Rated current : AC 0.5A~A Amb.temp. : 0 C h 0min 0min h Operating Characteristics : BHD,BHD( D) Rated current : AC 0.5A~A Amb.temp. : 0 C h 0min 0min min min 5min 5min 5min min 0s 0s s 5s s Min. s (0.5A~A) Max.(A~A) min Operating time min 0s 0s Max.(A~A) s 5s s Min. s 0.5s 0.s Operating time min Max. 0s 0s s 5s s 0.5s 0.s 0.s 0.s 0.05s 0.05s 0.05s 0.0s 0.0s 0.0s 0.0s s X0% of rated current nouter Dimensions X0% of rated current nambient Compensation Curve Neutral pole (+N only) Neutral pole Ambient compensation maximum 7 0 Current ratings (%) C 0.0s X0% of rated current M5 screw B Rated ambient temp Min. s 0.5s 0.s C Max. min 0.s B Operating Characteristics : BHD( B,C) Rated current : DC 0.5A~A Amb.temp. : 0 C h 0min 0min min min Operating time h h h 0 0 Solderless terminal Ambient temperature ( C) (rated ambient temp.: 0 C) P P P P

Instantaneous tripping TYPE B, C, D TYPE B, C TYPE B, C, D TYPE B, C IEC RCCB TYPE C IEC61008 RCBO 25, 40, 63A. IEC61009 Isolating Switch

Instantaneous tripping TYPE B, C, D TYPE B, C TYPE B, C, D TYPE B, C IEC RCCB TYPE C IEC61008 RCBO 25, 40, 63A. IEC61009 Isolating Switch Features (1) All models fully comply with IEC regulations (2) Units can be mounted on a standard 35mm IEC rail (3) Residual current circuit breakers use an original Mitsubishi Electric IC securing reliable

More information

Innovation That Leads the Change

Innovation That Leads the Change Innovation That Leads the Change Mitsubishi Electric s foray in the Low Voltage Switchgears segment in India marked the beginning of a series of innovations that are now gathering tremendous industry accolades..

More information

and other modular devices for low voltage installation

and other modular devices for low voltage installation Technical catalogue System and other modular devices for low voltage installation 2CSC400002D0204 SUMMARY Introduction Miniature Circuit-Breakers Residual Current Devices Auxiliary elements and accessories

More information

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

The breakers offer thermal-magnetic trip protection according to Z and K characteristics. Series High Performance Circuit Breakers Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific

More information

Jtec 10kA Miniature Circuit Breaker

Jtec 10kA Miniature Circuit Breaker EN 60898 Jtec 10kA Miniature Circuit Breaker Techna s JTEC range has been enthusiastically adopted by a diverse range of customers seeking a cost effective 10kA performance. Jtec MCBs are available in

More information

Manual Motor Starters. Meta-MEC

Manual Motor Starters. Meta-MEC Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters

More information

DRX 100 B/N/H Circuit breaker (not adjustable)

DRX 100 B/N/H Circuit breaker (not adjustable) 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (continuation) 2 4. MOUNTING 2 5. CABLING 3 6. ELECTRIC AND MECHANICAL

More information

DRX 125 Circuit breaker (not adjustable)

DRX 125 Circuit breaker (not adjustable) 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 272 20/21/22/23/24/25/26/27/55/56/57/58/59/60 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (continuation) 2 4.

More information

S200 UL 1077 Series S200. Supplementary protective devices. UL 1077 Series. Miniature. circuit breakers. S200 Supplementary protective devices

S200 UL 1077 Series S200. Supplementary protective devices. UL 1077 Series. Miniature. circuit breakers. S200 Supplementary protective devices UL 077 Series Supplementary protective devices The UL 077 Series miniature supplementary protector offers a compact solution for protection requirements. The devices are DIN rail mounted. The is available

More information

DRX 250 B/N/H Circuit breaker (not adjustable)

DRX 250 B/N/H Circuit breaker (not adjustable) 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 References rences: /18/19/20/21/22/23/24/25/26/27/28/29/ 32/33 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. MOUNTING 2 5.

More information

Miniature Circuit Breakers

Miniature Circuit Breakers S00 Series Miniature S00 Series Miniature Circuit Breakers Description The S00 Series miniature circuit breaker offers a compact solution for protection requirements. The S00 devices are UL tested limiting

More information

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories Page 1 of 5 MS132-10 ABB contact for United States of America General Information Extended Product Type: Product ID: EAN: Catalog Description: Long Description: MS132-10 1SAM350000R1010 4013614400100 MS132-10

More information

Jtec 489 UL489 Branch Circuit Breaker

Jtec 489 UL489 Branch Circuit Breaker Jtec 489 UL489 Branch Circuit Breaker 10kA Miniature Circuit Breaker R The Jtec 489 range is UL 489 listed (File E255530). Available in trip curves Z (v. quick), B (quick), C (medium), K (motor) and D

More information

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS 87045 LIMOGES Cedex Phone : + 33 5 55 06 87 87 Fax : + 33 5 55 06 88 88 R.C.B.O. DX 6000 A Phase + Neutral,, neutral on right side Cat. n (s) : 077 31 077 44-077 77 077 84 078 79 079 01-083 95 084 06 084

More information

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS MANUFACTURED IN THE EU EUROPEAN QUALITY 1, 2 & 3 POLE MCB s TRIPPING CURVES C & D CURRENT RATINGS 1AMP TO 63AMPS 10KA BREAKING CAPACITY

More information

QF(13) - Series Miniature Circuit Breakers

QF(13) - Series Miniature Circuit Breakers DIN Mount 1 pole DIN Mount 2 pole Dual Mount 3 pole Dual Mount 3 + N Features AC circuit breaker Hydraulic-magnetic technology % rating capability, independent of ambient temperature One, two, three, four

More information

S200 UL 489 Series. Miniature circuit breakers S200. Features. Description

S200 UL 489 Series. Miniature circuit breakers S200. Features. Description UL 489 Series UL 489 Series Description The Series miniature circuit breaker offers a compact solution for protection requirements. The U AND UP devices are UL 489 tested limiting and DIN rail mounted.

More information

NEW TX³ RANGE PROTECTION YOU CAN RELY ON

NEW TX³ RANGE PROTECTION YOU CAN RELY ON TX³ NEW RANGE TRUSTED PROTECTION FOR YOUR INSTALLATIONS GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES NEW TX³ RANGE PROTECTION YOU CAN RELY ON Designed to meet the requirements of

More information

max pole for t=15 ms

max pole for t=15 ms Types RI 61 RI 61N RI 61J RI 62 RI 62J RI 63 RI 63N RI 64 single-pole single-pole + neutral pole single-pole (for DC circuits) two-pole two-pole (for DC circuits) three-pole three-pole + neutral pole three-pole

More information

QF(19) - Series Miniature Circuit Breakers

QF(19) - Series Miniature Circuit Breakers Dual mount 1 pole Dual mount 2 pole Dual mount 3 pole Dual mount 3+N Features AC circuit breaker Hydraulic-magnetic technology % rating capability, independent of ambient temperature One, two, three pole,

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

DPX Magnetic only

DPX Magnetic only 87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 5. CONFORMITY

More information

W Datasheet: Residual current circuit breaker, series PRIORI, 10kA, Typ B

W Datasheet: Residual current circuit breaker, series PRIORI, 10kA, Typ B W Datasheet: Residual current circuit breaker, series PRIORI, 10kA, Typ B W SCHRACK-INFO All-current sensitive RCCB ( type B, B+ and Bfq) B+ types also meet the requirements of superior fire-protection

More information

LCIRCUIT BREAKERS. Jtec UL (Motor Disconnect) General Information...L2 Trip Curves & Dimensions...L3

LCIRCUIT BREAKERS. Jtec UL (Motor Disconnect) General Information...L2 Trip Curves & Dimensions...L3 Index L Springer Controls carries a complete line of Techna Miniature Circuit Breakers rated from 0.5 amps through 63.0 amps. Applications include usage in UL508A panels, motor group installations, motor

More information

cor Long Run Experience

cor Long Run Experience Moulded Case Circuit Breakers Moulded Case Circuit Breakers 16-1250A cor Long Run Experience cor Breaking capacity (according to IEC 947-2 at 415V) Icu 100 D160L D250L D400L D630L 70 60 DH800 50 35 30

More information

Data Sheet DIN Rail Miniature Circuit Breakers Ex9 Series - B1

Data Sheet DIN Rail Miniature Circuit Breakers Ex9 Series - B1 Data Sheet DIN Rail Miniature Circuit Breakers Ex9 Series B Ex9BE3C0 Ex9BHC6 www.noarkus.com NORK Ex9 Series B NORK Miniature Circuit Breakers offer these advantages: highperformance, small size, exemplary

More information

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when

More information

ABB STOTZ-KONTAKT GmbH

ABB STOTZ-KONTAKT GmbH ABB STOTZ-KONTAKT GmbH MULTIPLE 89 Motijheel C/A, Lucky Chamber (3rd floor, Room #61), Dhaka-1000, Bangladesh. Tel: (02) 9559692, Fax: (02)9566596 E-mail: info@multipletrading.net PAGE : 02 The ABB Line

More information

ACW Molded-Case Circuit Breaker UL 489 Listed

ACW Molded-Case Circuit Breaker UL 489 Listed Motors Automation Energy Transmission & Distribution Coatings Molded-Case Circuit Breaker UL 489 Listed Overview Introducing the WEG Series of Molded Case Circuit Breakers now available with UL489 certification.

More information

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers Series KTU7 UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s KTU7 series of UL Molded Case Circuit Breakers are UL489 and CE listed

More information

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Thermal-magnetic Miniature Circuit Breaker 4230-T... Thermal-magnetic Miniature Circuit Breaker 420-T... Description Single pole and multipole thermal-magnetic miniature circuit breakers (MCBs) in accordance with EN 60947-2, UL 077 and UL 489 for DIN rail

More information

Electronic circuit breaker EBU10-T

Electronic circuit breaker EBU10-T Description The electronic circuit protector type EBU10-T (Electronic Breaker Unit) provides selective overcurrent protection in AC 230 V UPS systems. It consists of an MCB approved for short circuit interruptions

More information

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. .

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. . 87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s 0090 00/01/02/06/07/11/12/13/14 0/01/02/06/07/11/12/13/14/18/19/23/24/25/26/ /18/19/23/24/25/26/45/46 45/46 0090

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

Data Sheet Manual Motor Starter Ex9S32 Series

Data Sheet Manual Motor Starter Ex9S32 Series Data Sheet Manual Motor Starter Ex9S32 Series na.noark-electric.com NOARK Ex9S32 Series Features Ex9S32 Manual Motor Starter provides manual isolation, manual motor control, and overcurrent protection

More information

Residual current circuit breakers with conditional shortcircuit

Residual current circuit breakers with conditional shortcircuit LFE Residual current circuit breakers RESIDUAL CURRENT CIRCUIT BREAKERS LFE Residual current circuit breakers with conditional shortcircuit current 6 ka. They react to sine-wave residual current (type

More information

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI . Technical Data and Specifications Ratings Frames EG, JG and LG EG JG LG Maximum rated current (amperes) 15, 160 1 50 400, 630 Breaker type 3 B B E S S H H C E S H C U X E S H C U X of poles 1, 3, 4,

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

DPX Thermal magnetic and trip-free switches DPX 3 -I 250 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 Reference(s) : 420 205/ 207/ 208/209/ 215/ 217/ 218/ 219/ 235/ 237/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.

More information

MCCB Accessories to suit AF

MCCB Accessories to suit AF MCCB s MCCB Accessories to suit 125-630AF Accessory fitting combinations INTERNAL General purpose types Micro-switch types Auxiliary Heavy duty types Bridge -contact types Auxiliary Shunt UVT Internal

More information

COMPLETE SOLUTIONS FOR POWER PROTECTION

COMPLETE SOLUTIONS FOR POWER PROTECTION COMPLETE SOLUTIONS FOR POWER PROTECTION GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES Modular protection P. 8 RX 3 MCBs 63 A 4500 & 6000 P. 18 DX 3 -IS isolating switches P. 9 RX

More information

schneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric.

schneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric. K0 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads Overview K0 Circuit Breaker Technical Specification MCB RCCB K0 Circuit Breaker K0N K0H ID K Number of poles

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

New DX 3 High rating & breaking capacity

New DX 3 High rating & breaking capacity New High rating & breaking capacity a new range OF MOduLar CirCuiT BrEakErs up TO 125 a T new dx³ MCBs AN ENHANCED range for HIgH-pErforMANCE INstALLAtIoNs DX³ : the new Legrand MCBs with dx³, Legrand

More information

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1. 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 LEXIC MCB s DX-H 80A, 100A, 125A Curv urves B and C CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1

More information

QF(26) - Series Miniature Circuit Breakers - Low Rating (5-63 A)

QF(26) - Series Miniature Circuit Breakers - Low Rating (5-63 A) QF(26) - Series Miniature Circuit Breakers - Low Rating (5-63 A) Dual Mount 1 pole Dual Mount 2 pole Dual Mount 3 + N Features AC circuit breaker Hydraulic-magnetic technology % rating capability, independent

More information

ACW. Molded-Case Circuit Breaker UL 489 Listed. ACW Catalog Number Sequence

ACW. Molded-Case Circuit Breaker UL 489 Listed. ACW Catalog Number Sequence rotection rotectors Contactors Overloads Relays ushbuttons Molded-Case Breaker UL 489 Listed The EG Series of Molded Case Breakers are designed to provide overload and short-circuit protection for industrial

More information

World Super Series WSS The extensive breaker series from Mitsubishi Electric

World Super Series WSS The extensive breaker series from Mitsubishi Electric MODEL PUSH TO TRIP TEST 3 P IEC60947-2 JIS C 8201-2 Ue 690VAC 00VAC 440VAC 41VAC 400VAC 380VAC 230VAC T Ir Ip Is Ts EN60947-2 40 C Icu/Ics 8/8kA 30/30kA 8/8kA MODEL POLE Ui 690VAC 0-60Hz 8kV Uimp PUSH

More information

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489 MINIATURE CIRCUIT BREAKERS SU200M Datasheet Branch protection acc. to CSA C22.2 No.5 / UL 489 The miniature circuit breaker SU200 M is ABB s solution for UL 489 branch circuit protection up to 480 Y/277

More information

CHINT. NM7 Moulded Case Circuit Breaker

CHINT. NM7 Moulded Case Circuit Breaker CHINT Moulded Case Circuit Breaker Moulded Case Circuit Breaker Application Product introduction Functions and characteristics Accessories Overall and dimension Specification selection and order Page

More information

Miniature Circuit Breaker

Miniature Circuit Breaker Introduction - Miniature Circuit Breaker (MCB) SALIENT FEATURES SALIENT FEATURES Standards MCBs conform to the latest standard IS 8828: 1996/IEC: 898 1995 Mid-Trip Position The Mid trip position of the

More information

DS201 - DS202C New residual current circuit-breakers with overcurrent protection (RCBOs)

DS201 - DS202C New residual current circuit-breakers with overcurrent protection (RCBOs) DS201 - DS202C New residual circuit-breakers with over protection (RCBOs) New residual circuit-breakers with over protection (RCBOs) - DS201 - DS202C 1P+N and 2P in two modules. Complete protection To

More information

MS General Information Extended Product Type: MS

MS General Information Extended Product Type: MS MS132-1.6 General Information Extended Product Type: MS132-1.6 Product ID: 1SAM350000R1006 EAN: 4013614400063 Catalog Description: MS132-1.6 Manual Motor Starter Long Description: The MS132-1.6 manual

More information

MINIATURE CIRCUIT BREAKER

MINIATURE CIRCUIT BREAKER Technical Article MINIATURE CIRCUIT BREAKER T 146 PURCHASE he Spaceage MCB protects wires and cables automatically against overload and short-circuits in domestic, commercial and industrial installations.

More information

Protection Equipment

Protection Equipment Protection Equipment Price Groups 101, 102, 121, 131, 143 /2 Introduction Motor Starter Protectors/ Circuit Breakers SIRIUS 3RV2 Motor Starter Protectors up to 40 A new /7 General data /13 For motor protection

More information

Cat N 3. OVERALL DIMENSIONS

Cat N 3. OVERALL DIMENSIONS Cat N Motor driven remote control module 87045 LIMOGES Cedex - FRANCE Telephone : + 33 5 55 06 87 87 Fax: + 33 5 55 06 88 88 Cat N : : 4 062 91 CONTENTS PAGE 1. Description - Use...1 2. Product range...1

More information

3VU13, 3VU16 Circuit-Breakers

3VU13, 3VU16 Circuit-Breakers 3VU3, 3VU6 Circuit-Breakers Description The 3VU3, 3VU6 circuit-breakers are compact circuit-breakers for currents up to 80 A which operate according to the current limiting principle. The devices are used

More information

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427 Data sheet CI-TI TM Contactors and Motor Starters Circuit Breakers November 2002 DKACT.PD.C00.L2.02 520B1427 Introduction Circuit breakers/manual motor starters cover the power ranges 0.09-12.5 kw This

More information

DPX earth leakage DPX 3 -I earth leakage

DPX earth leakage DPX 3 -I earth leakage 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 + earth leakage Reference(s) : 420 225/ 227/ 228/229/ 255/ 257/ 258/ 259/ 285/ 287/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3.

More information

The effective choice The benefits of a product with the highest quality standards

The effective choice The benefits of a product with the highest quality standards The effective choice The benefits of a product with the highest quality standards Compact size for easy installation in small spaces and retrofitting of already existing facilities. Terminals designed

More information

RESIDUAL CURRENT CIRCUIT BREAKERS OFE (6 ka)

RESIDUAL CURRENT CIRCUIT BREAKERS OFE (6 ka) Residual current circuit breakers RESIDUAL CURRENT CIRCUIT BREAKERS OFE ( ka) Standard type for common use in building and housing installations up to 3 A, 230/400 V a.c. They react to alternating sine-wave

More information

The new SH200 MCBs can be used in domestic, commercial and industrial applications for protection against over-current and short circuit.

The new SH200 MCBs can be used in domestic, commercial and industrial applications for protection against over-current and short circuit. s Product Overview SH200 The new SH200 s can be used in domestic, commercial and industrial applications for protection against over-current and short circuit. New Enhancement Optimized connection terminal

More information

Data Sheet DIN Rail Miniature Circuit Breakers Ex9 Series - B1NQ

Data Sheet DIN Rail Miniature Circuit Breakers Ex9 Series - B1NQ Data Sheet DIN Rail Miniature Circuit Breakers Ex9 Series - BNQ BNQD5T BNQD5 with Front Mounting Clips na.noark-electric.com NOARK Ex9 Series - BNQ Features The BNQ is compliant with UL/CSA/IEC standards

More information

Miniature Circuit-Breakers (MCBs)

Miniature Circuit-Breakers (MCBs) Product Overview Miniature Circuit-Breakers (MCBs) Design Tripping characteristics Rated current I n Rated breaking capacity Power supply company product range 5SP3 E 16 - A Standard product range 5SQ2

More information

Miniature circuit breakers

Miniature circuit breakers Miniature circuit breakers Miniature circuit breaker ETIMAT 6 Rated short-circuit capacity Rated current Tripping characteristic 6 ka 6-63 A B, C 1-pole 6 230/400 002111512 002141512 112 12/108 10 230/400

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 630

DPX Thermal magnetic and trip-free switches DPX 3 -I 630 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 2 6. CONFORMITY

More information

Get detailed information on many digital or printed supports, or contact your Area Commercial Manager

Get detailed information on many digital or printed supports, or contact your Area Commercial Manager The RX 3 and DX-E ranges provide essential functions for the protection requirements of people and property in residential and small commercial buildings Two breaking capacities, 4500 and 6000 (IEC 60898-1)

More information

UMBW-UL489 and UL1077 Listed

UMBW-UL489 and UL1077 Listed -UL489 and UL77 Listed Introducing the New WEG Series Thermal-Magnetic Miniature Breakers. This new offering includes both UL489 and UL77 approvals to provide a solution for circuit & equipment protection

More information

Data Sheet Manual Motor Starter Ex9S32 Series

Data Sheet Manual Motor Starter Ex9S32 Series Data Sheet Manual Motor Starter Ex9S32 Series na.noark-electric.com NOARK Ex9S32 Series Features Ex9S32 Manual Motor Starter provides manual isolation, manual motor control, and overcurrent protection

More information

RESIDUAL CURRENT CIRCUIT BREAKERS OFI (10 ka)

RESIDUAL CURRENT CIRCUIT BREAKERS OFI (10 ka) Residual current circuit breakers RESIDUAL CURRENT CIRCUIT BREAKERS OFI (10 ka) They react to both alternating sine-wave residual current and pulsating direct current (type A) For protection: against accidental

More information

Basic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors

Basic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors MOTOR STARTERS SM Basic function Switching and protection of motors up to A Protection against short-circuit and protection against overload The device responds to phase failure The device is provided

More information

www. ElectricalPartManuals. com Miniature Circuit Breakers Section 7

www. ElectricalPartManuals. com Miniature Circuit Breakers Section 7 EP60 Series...7-2 EP100 Series...7-4 EP100 ULH Series...7-6 EP100 UC Series (Branch Circuit Protection)...7-8 Series CA Auxiliary Switch and Bell Alarm...7-10 Series CB Auxiliary Switch and Bell Alarm...7-11

More information

Technical catalogue. System pro M. Residual current devices 2CSC420001D0201

Technical catalogue. System pro M. Residual current devices 2CSC420001D0201 Technical catalogue System pro M Residual current devices 2CSC42000D020 SUMMARY Residual current devices Technical details and guide to applications Overall dimensions 2 3 ABB SACE and its commitment to

More information

Protection components

Protection components Presentation, characteristics Presentation 1 2 3 motor circuit-breakers are 3-pole thermal-magnetic circuit-breakers standards IEC 60947-2 and IEC 60947-4-1. Connection These circuit-breakers are designed

More information

Series L9 UL-489 Miniature Circuit Breakers

Series L9 UL-489 Miniature Circuit Breakers Series UL-489 iniature Breakers Industrial Breakers for Branch up to 40 Amps Sprecher+Schuh includes a line of circuit breakers approved for branch circuit applications in the United States and Canada

More information

S200 UL 489 Series. Miniature Circuit Breakers. Description. Features

S200 UL 489 Series. Miniature Circuit Breakers. Description. Features S200 UL 489 Series Miniature S200 UL 489 Series Miniature Circuit Breakers Description The S200 Series miniature circuit breaker offers a compact solution for protection requirements. The S200U AND S200UP

More information

LOW VOLTAGE SWITCHGEAR

LOW VOLTAGE SWITCHGEAR LOW VOLTAGE SWITCHGEAR S-N Motor Control Mitsubishi Electric s S-N Series contactors are perfect for the control of 3 phase power, either for the direct control of a motor, to supply power to a drive or

More information

Low voltage moulded case circuit breaker EB2

Low voltage moulded case circuit breaker EB2 Low voltage moulded case circuit breaker EB2 Product series description unit condition Model-type Number of poles Nominal current ratings Electrical characteristics Rated operational voltage Rated insulation

More information

QUALITY ASSURANCE & DOCUMENTATION

QUALITY ASSURANCE & DOCUMENTATION QUALITY ASSURANCE & DOCUMENTATION RTECK IMPORTED PRODUCT STATEMENT Rteck has sourced most product from a large and reputable Chinese product manufacturer who specialise in the manufacture of modular electrical

More information

Phase + Neutral, neutral on left side

Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGE 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A Fuse protection The solution for > Motor load break > Protection of industrial cabinet > Electrical distribution fusom_063_b_1_cat Strong points > Tripping upon overload > High breaking capacity > Improved

More information

W DATASHEET: MINIATURE CIRCUIT BREAKER (MCB), SERIES AMPARO

W DATASHEET: MINIATURE CIRCUIT BREAKER (MCB), SERIES AMPARO W DATASHEET: MINIATURE CIRCUIT BREAKER (MCB), SERIES AMPARO W SCHRACK-INFO Lift and clamp terminals on both sides Terminal guide for secure connection Terminal cross-section: 1-25mm² Snap-on mounting for

More information

NB1 Miniature Circuit Breaker

NB1 Miniature Circuit Breaker P-00 Modular DIN Rail Products MCB NB Miniature Circuit Breaker Color coded contact position indicator provides visual indication of the device status and insulation function Magnetic trip elements provide

More information

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers Series UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s series of UL are UL489 and CE listed for global applications. The current

More information

NDM1 Series MCB Edition

NDM1 Series MCB Edition NDM1 Series MCB 2016 Edition COMPANY PROFILE Shanghai Liangxin Electrical Co., LTD. one of the leading low-voltage electrical component manufacture in the high-end market, was established in 1999. Nader

More information

Residual Current Protective Devices / Arc Fault Detection Devices (AFDDs)

Residual Current Protective Devices / Arc Fault Detection Devices (AFDDs) Introduction Overview Devices Page Application Standards Used in / Personnel, material and fire protection, as well as protection against direct contact. SIGRES with active condensation protection for

More information

MCBs and RCDs LR TM 6000

MCBs and RCDs LR TM 6000 MCBs and RCDs LR TM 6000 thermal magnetic MCBs from 6 A to 63 A B and C curves residual current devices from 25 A to 63 A AC and A types ± ± ± ± MCBs Single pole 230/400 V± Single pole neutral 230 V± (1)

More information

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

RX 3 MCB 4500 A Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 RX 3 MCB 4500 A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

MOULDED CASE CIRCUIT BREAKERS BC160N

MOULDED CASE CIRCUIT BREAKERS BC160N D MOULDED CASE CIRCUIT BREAKERS BC160N D BC160N COMMERCIAL INFORMATION Circuit breakers...d4 Switch-disconnectors...D5 Connecting sets......d6 Mounting sets......d6 Switches...D7 Shunt trips...d7 Undervoltage

More information

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DNX 3 MCB 4500 A / 6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation

More information

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489 System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU 200 M is ABB s solution for UL 489 branch

More information

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

Specification for 70mm pole pitch Air circuit breaker up to 1600 A Specification for 70mm pole pitch Air circuit breaker up to 1600 A Protective device for low voltage electrical installation Last update :2011-07-08-1 - Table of contents: 1 General...3 2 Compliance with

More information

IP20 degree of protection; IP40 degree of protection after installation in a distribution box

IP20 degree of protection; IP40 degree of protection after installation in a distribution box RI 50 RI 50 is used for the protection of installations and devices (overload and short circuit), and as a disconnector in case of electric shock Simple and quick fixing to a 35 mm mounting rail in accordance

More information

SWITCH FUSES 3KL71 from 32A to 800A Description

SWITCH FUSES 3KL71 from 32A to 800A Description from 32A to 800A Description SWITCH FUSES 3KL71 3KL71 is a range of load-break switches suitable for making and breaking on load and disconnetting low voltage electrical circuits. They are commonly used

More information

TX³ RCCBs 2P up to 100 A

TX³ RCCBs 2P up to 100 A 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 TX³ RCCBs CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

Motor Protection Circuit Breakers 3VU13 and 3VU16

Motor Protection Circuit Breakers 3VU13 and 3VU16 Motor Protection Circuit Breakers 3VU13 and 3VU16 3VU13/3VU16 is suitable for use in fuseless motor feeders upto 11KW/22KW (25A/63A) respectively. 3VU motor protection circuit breakers are used for protection

More information

Thermal-Magnetic Circuit Breaker M1-...

Thermal-Magnetic Circuit Breaker M1-... Thermal-Magnetic Circuit Breaker 320-...-M-... Description Two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 6034). The addition of a magnetic tripping

More information

DSE201 Compact design with enhanced protection

DSE201 Compact design with enhanced protection DSE201 Compact design with enhanced protection The best of safety DSE201 6 ka: the highest level of reliability The 1P+N electronic residual current circuit-breakers with overcurrent protection (RCBOs)

More information

DPX Electronic + earth leakage

DPX Electronic + earth leakage 87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 DPX 3 250 Electronic + earth leakage CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. ELECTRICAL AND MECHANICAL

More information

Product Line Overview. The Most Logically Designed Contact Assembly

Product Line Overview. The Most Logically Designed Contact Assembly Circuit Breakers & Supplementary Protectors 15 00 Amperes for UL, CSA & IEC Applications Product Line Overview -3 General Information Cutler-Hammer Series G Molded Case Circuit Breakers provide increased

More information

CONTENTS Part I Intelligent Air Circuit Breaker(ACB) 01 UEW5 series Intelligent Air Circuit Breaker Part II Molded Case Circuit Breaker(MCCB)

CONTENTS Part I Intelligent Air Circuit Breaker(ACB) 01 UEW5 series Intelligent Air Circuit Breaker Part II Molded Case Circuit Breaker(MCCB) CONTENTS Part I Intelligent Air Circuit Breaker(ACB) 01 UEW5 series Intelligent Air Circuit Breaker 02 Part II Molded Case Circuit Breaker(MCCB) 07 UEM5 series Molded Case Circuit Breakers 08 UEM5L series

More information