E2C/E2C-H. Separate Amplifier Sensor with Sensitivity Adjustment. Separate Amplifier Proximity Sensor with Adjustment Potentiometer

Size: px
Start display at page:

Download "E2C/E2C-H. Separate Amplifier Sensor with Sensitivity Adjustment. Separate Amplifier Proximity Sensor with Adjustment Potentiometer"

Transcription

1 Separate mplifier Proximity with djustment Potentiometer E/E-H Separate mplifier with Sensitivity djustment ompact design with smaller Head. Heat-resistance model available for application between and. SM_E_E-H_S_E e sure to read Safety Precautions on page. Ordering Information s [Refer to imensions on page.] Standard Models ppearance Stable sensing area * Model ombination Model mplifier Units Power supply/ Output Timer function Self-diagnostic output. dia.. (.) mm E-R M. dia.. (.) mm E-R M M () mm E- M E-GE E-GF / (NPN) / (PNP) Shielded. dia. () mm E- M M. () mm E-R M E-JP M * / (NPN) Yes Yes M M M () mm () mm () mm E- M E- M E- M E-J M E-M / (NPN) / NPN PNP Yes Unshielded dia. E-M M () mm *. Values in parentheses are for the maximum sensing distances at. E-K * Self-diagnostic output, timer, and IN Track mounting. Heat-resistant Model ppearance Stable sensing area Model M. mm E-RH M Shielded M mm E-H M M mm E-H M Note: haracteristics will change if the cable length changes. o not cut or extend the cable. mplifier Unit ombination Model E-JH M E-JH M E-JEH M

2 E/E-H ccessories (Order Separately) Mounting rackets Mounting racket is not provided with the. Order a Mounting racket separately if required. [Refer to imension on page.] Name Model pplicable s Remarks Y9E-FR E-R, for. dia. Mounting rackets --- Y9E-FR E-, for. dia. onnection Sockets Socket is not provided with the mplifier Unit. Order a Socket separately if required. [Refer to imension on page.] Name Model pplicable mplifier Unit Remarks E-GE PYF E-GF Front onnection Sockets PF- E-M PF- E-K ack onnection Sockets PG- E-M PG- E-K Hold-down lips (Order Separately) PY- Sold as a set. dapters n dapter is not provided with the mplifier Unit. Order an dapter separately if required. [Refer to imension on page.] Name Model pplicable mplifier Unit Remarks Y9F- Embedded dapters Y9F- E-M/-K --- Y9F- For details on Mounting rackets, Protective overs, and Sputter Protective overs, refer to ccessories on Y9@. ---

3 Ratings and Specifications E/E-H Standard Models s Model E-R/ E-/ E-R E- E- E- E-M Item -R - Sensing distance. mm mm mm mm mm mm mm (at ) Stable sensing area mbient temperature ifferential travel to. mm to mm to. mm to mm to mm to mm to mm t to to. mm to. mm to mm to. mm to mm to mm to mm Refer to Ratings and Specifications on page for mplifier Unit specifications. etectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering ata on page.) mbient temperature range mbient humidity range Temperature influence Vibration resistance Shock resistance egree of protection onnection method * Iron, mm Iron, mm Iron, mm Iron, mm Iron, mm khz Hz Hz Hz Hz Operating/Storage: to (with no icing or condensation) Operating/Storage: % to 9% (with no condensation) % max. of sensing distance at in the temperature range of to estruction: to Hz,.-mm double amplitude for hours each in and Y directions estruction: m/s times each in and Y directions IE 9 IP, in-house standards: oil-resistant Pre-wired Models High-frequency coaxial cable (Standard cable length: m) Iron, mm Weight (packed state) pprox. g pprox. g pprox. g pprox. g pprox. g pprox. g pprox. g ase Stainless steel rass Standard sensing object Response frequency * Materials Sensing surface able S resin Polyethylene lamping nut --- rass, nickel-plated (except E-) Toothed --- rass, zinc-plated (except E-) washer ccessories --- *. The minimum value when using the solid-state control output on the mplifier Unit. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance. *. Refer to for cable lengths when combining mplifier Units and s. The characteristic impedance of the high-frequency coaxial cable is Ω.

4 E/E-H mplifier Units Item Model E-GE E-GF E-J E-JP E-M E-K Power supply voltage (operating voltage range) to V ( to V), ripple (p-p): % max. * to V (9 to V) / Hz urrent consumption Sensing distance adjustment range * ifferential travel adjustment range % min. of rated sensing distance with -turn potentiometer Response time Solidstate m max. m max. m max. m max. ifferential travel fixed (% max. of sensing distance) (Refer to the response frequency of the Proximity.) % to % of rated sensing distance with -turn potentiometer % to % of rated sensing distance Relay --- ms max. ontrol outputs Solidstate NPN Load resistance:. kω, m max. ( V max.) (Residual voltage:. V max.) PNP Load resistance:. kω, m max. ( V max.) (Residual voltage:. V max.) NPN Open-collector output m max. ( V max.) (Residual voltage:. V max.) (E-JP: V max.) NPN/PNP output Open-collector output m max. ( V max.) (Residual voltage:. V max.) Transistor/photocoupler m max. ( V max.) (Residual voltage: V max.) Relay --- Relay output, SPT at V, cosφ = (resistive load) * Indicators etection indicator (red) (OPERTI) etection indicator (red) (OPERTI) Stability indicator (green) (STILITY) etection indicator (red) (OPERTI) Stability indicator (green) (STILITY) Operation mode Self-diagnostic output hanged with NO/N switch. --- (E-JP only) Output transistor turns when open circuit or unstable sensing is detected; solid-state NPN open-collector m max. ( V max.) (Residual voltage: V max.) Timer function --- -delay: ± ms --- able length compensation between and mplifier Unit mbient temperature range mbient humidity range Temperature influence Voltage influence Insulation resistance ielectric strength Vibration resistance --- Operating/storage: to (with no icing or condensation) (E-JP only) m/ m, terminals Short-plate switching Shorted: to m Open: to m Operating/Storage: % to % (E-JP: % to 9%) (with no condensation) % max. of sensing distance at in the temperature range of to Models: ±% max. of sensing distance at rated voltage in the rated voltage ±% range Models: ±% max. of sensing distance at rated voltage in the rated voltage ±% range MΩ min. (at V) between current-carrying parts and case Models:, V, / Hz for min between current-carrying parts and case Models:, V, / Hz for min between current-carrying parts and case estruction: to Hz, -mm double amplitude for hours each in, Y, and Z directions estruction: to Hz,.-mm double amplitude for hours each in, Y, and Z directions *. full-wave rectification power supply of V ±% (average value) can be used (except for the E-GE@). *. The sensing distance range required to maintain performed is given for using the mplifier Unit in combination with the. *. Internal relay: GR- V --- Mode switched with -position switch. estruction: to Hz, -mm double amplitude for hours each in, Y, and Z directions

5 E/E-H Item Shock resistance Model E-GE E-GF estruction: m/s times each in, Y, and Z directions Life expectancy --- onnection method Terminal block E-J E-JP Pre-wired Models (Standard cable length: m) E-M Terminal block E-K Mechanical:,, operations min. Electrical:, operations min. Weight (packed state) * pprox. g E-J: pprox. g E-JP: pprox g pprox. g pprox. g ccessories Instruction manual aution labels, Mounting racket (E-J: M Phillips mounting screw), instruction manual Instruction manual *. The weight of the onnection Socket is not included. Heat-resistant Models s mplifier Units Item Model etectable object Standard sensing object Stable sensing area E-RH E-H E-H Ferrous metal (The sensing distance decreases with non-ferrous metal, refer to Engineering ata on page.) Iron, mm Iron, mm Iron, mm to. mm to mm to mm ifferential travel. mm max.. mm max. Response frequency * mbient temperature range mbient humidity range Temperature influence Vibration resistance Shock resistance egree of protection Weight (packed state) onnection method Materials ase Sensing surface able lamping nut Hz Operating/Storage: to (with no icing or condensation) Operating/Storage: % to 9% (with no condensation) ±.%/ estruction: to Hz,.-mm double amplitude for hours each in, Y, and Z directions estruction: m/s times each in, Y, and Z directions IE 9 IP * Pre-wired Models (able length: m) Heat-resistant, high-frequency coaxial cable pprox. g pprox. g pprox. g rass PEEK (polyether ether ketone) Fluorine resin rass, nickel-plated Toothed washer Iron, zinc-plated Note: Ratings and characteristic are given for % of the stable sensing area. *. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance. *. o not operate the in areas exposed to water vapor because the enclosure is not waterproof. Item Model E-JH E-JH E-JEH Power supply voltage * (operating voltage range) Sensing distance adjustment range * urrent consumption ontrol outputs Indicators Load current Residual voltage Operation mode able length compensation mbient temperature range mbient humidity range Temperature influence Voltage influence Insulation resistance ielectric strength Vibration resistance Shock resistance egree of protection onnection method Weight (packed state) ccessories to V ( to V), ripple (p-p): % max. m max. % to % of rated sensing distance -turn potentiometer NPN open collector, m max. ( V max.). V max. etection indicator (red) hanged with NO/N switch. Switched between and m. Operating/storage: to (with no icing or condensation) Operating/storage: % to % (with no condensation) ±.%/ ±% max. of sensing distance at rated voltage in the rated voltage ±% range MΩ min. (at V) between current-carrying parts and case, V, / Hz for min between current-carrying parts and case estruction: to Hz,.-mm double amplitude for hours each in, Y, and Z directions estruction: m/s times each in, Y, and Z directions IE 9 IP Pre-wired Models (able length: m) pprox. g aution labels, Mounting racket, instruction manual *. full-wave rectification power supply of V ±% (average value) can be used. *. The sensing distance range required to maintain performed is given for using the mplifier Unit in combination with the.

6 able Lengths for -mplifier Unit ombinations E/E-H Standard Models E- E- E-R E-R E- E- E- E- E- mplifier Units R M E-GE Restricted to m. E-GF E-JP to m: Short cable length terminals * to m: Open cable length terminals * E-J Restricted to m E-M E-K to m Set cable length switch to desired position. * to m Set cable length switch to desired position. * Note: The standard cable length is m. Models with -m or -m are manufactured upon order. * Refer to page for the operation of cable length switching. Heat-resistant Models mplifier Units E-RH E-H E-H E-JH E-JH Set m/ m cable length switch to desired position. E-JEH Note: The standard cable length is m. Models with -m are manufactured upon order. Self-diagnostic Function The self-diagnostic output transistor will turn in the following cases. (The output will turn for any of these conditions individually.) () open circuit: Transistor will turn the instance there is an open circuit for the (including the cable). Open ircuit onnected Sensing distance: pprox. % Set distance: % pprox. 9% Indicators Sensing object ontrol output (NO) Self-diagnostic output etection indicator (red) Stability indicator (green) () etection: The output will turn if a sensing object is within 9% to % of the sensing distance continuously for. s or longer (e.g., for sensing object position offset). () No detection: The output will turn if a sensing object is within % to % of the sensing distance continuously for. s or longer (e.g., when background is influencing detection). Indicators Present None Red Open circuit Red Open circuit eliminated Green Open circuit Open circuit eliminated Indicators ontrol output (NO). s min.. s min. Self-diagnostic * * output etection indicator (red) Stability indicator (green) Green Red Green Time Green Note: When the E- is used, 9% is 9% and % is %. * The self-diagnostic output may turn if the sensing objects moves a low speed. In actual application, include an -delay timer circuit or other suitable measure. The detection indicator lights when a sensing object approaches the sensing distance to indicate that a sensing object has been detected. The stability indicator lights when the sensing object approaches within 9% of the sensing distance or moves away from % of the sensing distance to indicate a stable sensing or non-sensing condition. Stable nonsensing area etection indicator (red) Stability indicator (green) Set distance pprox..* Set distance Stable sensing area Set distance pprox..9* * When the E- is used, % is % and 9% is 9%.

7 Engineering ata (Reference Value) E/E-H Sensing rea istance (mm)..... Y Sensing distance (variable):. to. mm %... % % Sensing Head istance Y (mm) E-/- E-R E- istance (mm)..... Y Sensing distance (variable):. to mm % istance (mm)... Y Sensing distance (variable):. to. mm % istance (mm) Y Sensing distance (variable):. to mm %. %. % %.. %. % % E- Sensing Head E- Sensing Head istance Y (mm) Sensing Head istance Y (mm) E- E- E-M istance (mm) Y Sensing distance (variable): to mm % istance (mm) Y Sensing distance (variable): to mm % istance (mm) Y Sensing Head istance Y (mm) Sensing distance (variable): to mm % % % % % % % Sensing Head istance Y (mm) Sensing Head istance Y (mm) Sensing Head E-RH + E-JH E-H + E-JH E-H + E-JEH istance (mm).. Y Sensing distance (variable):. to. mm % istance (mm) Y Sensing distance (variable):. to mm % istance (mm) Y Sensing distance (variable): to mm % istance Y (mm) % % %. % % % Sensing Head istance Y (mm) Sensing Head istance Y (mm) istance Y (mm) Sensing Head

8 E/E-H Influence of Sensing Object Size and Material istance (mm).... d d t = mm. Iron... Side length of sensing object: d (mm) E-/- E-R E- istance (mm) d d t = mm Iron Stainless steel (SUS) rass luminum istance (mm)..... d d t = mm Iron Stainless steel (SUS) luminum rass istance (mm) d d t = mm Iron Stainless steel (SUS) luminum rass Side length of sensing object: d (mm) Side length of sensing object: d (mm) E- E- E-M istance (mm) d d t = mm Iron Stainless steel (SUS) rass luminum Side length of sensing object: d (mm) istance (mm) d d t = mm Stainless steel (SUS) Side length of sensing object: d (mm) Side length of sensing object: d (mm) E-RH + E-JH E-H + E-JH E-H + E-JEH istance (mm)... d d t = mm Iron Stainless steel (SUS) rass luminum istance (mm).... d d t = mm Iron Iron rass luminum Stainless steel (SUS) rass luminum istance (mm) istance (mm) d d t = mm Iron Stainless steel (SUS) rass luminum 9 Side length of sensing object: d (mm) d d t = mm Iron Stainless steel (SUS) rass luminum Side length of sensing object: d (mm) Side length of sensing object: d (mm) Side length of sensing object: d (mm)

9 I/O ircuit iagrams E/E-H Output configuration E-GE * to V E-J, E-JH, E-JH, E-JEH NPN output Proximity main circuit. kω m max.. Ω V 9 Output * voltage output can be used if the NO/N switch on the E-GE is set to N, but an approximately -ms pulse will be generated when the power supply is turned. n initial reset will thus be required. If the E-GF (model for PNP output) is used, the initial pulse will not occur. V Proximity main circuit m max.. Ω V rown to V lack Output lue V E-JP NPN output Self-diagnosis Function etection indicator (Red) Stability indicator (Green) Proximity main circuit. Ω.9 Ω Z rown lack Output lue Load to V m max. V Z Z : VZ = V Orange Self-diagnostic output m max. E-GF to V PNP Output Proximity main circuit. kω m max. V. Ω 9 Output V E-M oth NPN and PNP outputs Proximity main circuit m max. V. Ω V. Ω to V Output (PNP) Output (NPN) V E-K Transistor/ photocoupler Relay output Proximity main circuit m max.. Ω V Output (+) Output ( ) Note: Terminals,, and are the relay contact output (SPT). 9

10 onnections between mplifier Unit and E/E-H E-J E-JP Proximity Proximity Proximity E-GE: NPN output E-GF: PNP output Line 9 to V Shield pplicable Socket: PYF Shield Line rown lack lue -delay operation terminal* to V NPN opencollector output V * -delay timer setting If the -delay operation terminals are shorted, a -ms -delay timer will start. Shield Line cable length compensation terminals* rown to V lack NPN opencollector output lue V Orange * able Length ompensation These terminals can be use to switch the cable length. Terminals shorted: to m Terminals open: to m Self-diagnostic output E-K E-M E-J@H Proximity Transistor/photocoupler output ( ) (+) Proximity Shield Line Shield Line pplicable Socket: PF- 9 Tc Ta Tb to V Relay output pplicable Socket: PF- PNP V to NPN Output V output Shield Line rown lack lue to V NPN opencollector output V Note: haracteristics will change if the cable length changes. o not cut or extend the cable.

11 Load onnections E/E-H Load Model E-J, load Relay Solenoid urrent-sinking load Programmable ontroller ontroller rown Load lack lue Voltage load (logic circuit) rown lack lue. k to V +V To next stage V Interface circuits Logic circuit Load Model E-GE load Relay Solenoid 9 Load Solid-state load Programmable ontroller ontroller mplifier Unit Voltage load (logic circuit) mplifier Unit Tr 9 I: m max. HFE: m max. VE: V min.. K ¼W.K ¼W VV : V. μ. K ¼W Interface circuits Tr to V +V To next stage V ( V) Solid-state circuit Remarks When connecting to a MOS I or TLL, provide an interface circuit as shown above and connect to the solid-state circuit in the next stage.

12 E/E-H Load Model E-K E-M load Relay Solenoid mplifier Unit Ta Tc Relay output Load Power supply or ( to V) PNP Output * Load mplifier Unit NPN output IL ( V) m max. Load * Use V maximum when connecting the load to a separate power supply. Solidstate load urrent-sinking load (photocoupler) Programmable ontroller ontroller mplifier Unit Transistor/photocoupler output m max. IL Load * For a current-sourcing load, connect to the negative side of the transistor/photocoupler output. ( to V) (PNP output) Load mplifier Unit NPN output IL ( V) m max. * For a current-sourcing load, connect the PNP output. Voltage loads (logic circuit) mplifier Unit Transistor/photocoupler output ( to V) ( to V) PNP Output mplifier Unit ( V) ( V) The E-K supports relay and transistor/photocoupler outputs, and the E-M supports both NPN and PNP open-collector output. They can be connected to a wide variety of load types and power polarities. Nomenclature and Timing harts mplifier Units E-G@ etection indicator (red) Timing hart Operation switch hanges NO/N. Sensing distance adjuster (-turn potentiometer) Operation switch NO N Sensing object Present Not present Transistor output (voltage output) etection indicator (red) E-J -delay operation terminals Stability indicator (green) Sensing distance adjuster Mounting screw etection indicator (red) Operation switch hanges NO/N. Timing hart Operation switch NO N Sensing object Present Not present Output transistor Note: Terminals shorted: -delay operation enabled. Output transistor Note: Terminals open: -delay operation disabled. etection indicator (red) ms ms

13 E/E-H E-JP able length compensation terminals Stability indicator (green) Sensing distance adjuster Timer switch : ms : No delay Mounting screw etection indicator (red) Operation switch hanges NO/N. Output transistor Operation mode selector Timing hart NO N Sensing object Present Not present Timer switch: (-delay operation enabled.) Timer switch: (-delay operation disabled.) etection indicator (red) ms ms E-JH, E-JH, E-JEH Hood mounting screw Timing hart Sensing distance adjuster etection indicator (red) NO Sensing object Present Not present Output transistor etection indicator able length compensation switch Mode selector N Sensing object Present Not present Output transistor etection indicator

14 E/E-H Operation switch hanges NO/N. able length compensation switch* ifferential travel adjuster * able Length ompensation Switching Set this switch to the proper setting depending on whether the standard cable length is being used or the cable has been cut shorter. mplifier Unit Switch Settings The detection indicator (red) indicates the detection status. (Object detected:, No object detected: ) Stability indicator (green) Indicates that the detection or non-detection level is stable. (Stable:, Unstable: ) Sensing distance adjustment (-turn potentiometer) Operation switch NO N Sensing object Present Not present Relay output (transistor output) etection indicator (red) Timing hart pplicable s E-R E-R E- E- E-R E- E- E- E-M able length to m to m to m to m to m to m to m to m to 9 m 9 to m Note:. Mutual Interference Prevention: When mounting s with the same diameter and cable length in parallel, set the IP switch to modes that differ by m in cable length. Specifications, however, may not be sufficiently met, so always check operation before actual application. This method cannot be used for the E-M.. When using the E-R + E-M (or K), set all the pins on the mplifier Unit IP switch to the left.

15 Safety Precautions Refer to Warranty and Limitations of Liability. WRNING This product is not designed or rated for ensuring safety of persons either directly or indirectly. o not use it for such purposes. E/E-H Mounting o not use excessive force when tightening the nuts on the E- and E-M. washer must be used with the nut. Precautions for orrect Use o not use the Encoder under ambient conditions that exceed the ratings. esign Influence of Surrounding Metal When mounting the within a metal panel, ensure that the clearances given in the following table are maintained. Failure to maintain these distances may cause deterioration in the performance of the. l m d dia. Influence of Surrounding Metal (Unit: mm) Model istance l d m E-R (.). E- () E- (.) E-R(H) (). E-(H) () E-(H) () E- () E-M Note: Values in parentheses for diameter d are the outer diameters of Shielded Models. Mutual Interference When installing s face-to-face or side-by-side, ensure that the minimum distances given in the following table are maintained. Mutual interference can be prevented by using the cable length compensation switch, but doing so will also change coil characteristics. Specifications such as temperature specifications and sensing distance, may not be sufficiently met, so always check operation before actual application. This method cannot be used for the E-G@, E-J, E- M. Model Torque E-.9 N m E-R(H). N m E-(H).9 N m E-(H) N m E- 9 N m E-M N m Note: The above leeways in tighten torque assume that a toothed washer is being used. Mounting Unthreaded ylindrical Models When using a set screw, tighten it to a torque of. N m max. impled end of set screw (M) to. mm Y9E-FR Mounting racket (for. dia.) (Order Separately) The Y9E-FR (for. dia.) is also sold separately. Mutual Interference (Unit: mm) Model istance E-R E- E- E-R(H) E-(H) E-(H) E- E-M Note: The above values are for a differential travel setting of %.

16 E/E-H Mounting Mounting the mplifier Unit E-J Lengthwise Mounting ()Secure the Mounting racket with the enclosed M screws. ()Loosen the M. cover screw and remove the cover. ()Slide the protrusion on the mplifier Unit into the hole on the Mounting racket. ()Using the M mounting screw inside the mplifier Unit, secure the mplifier Unit to the mounting base. ()Secure the cover to the case. M. cover screw E-@ Using PF-, PF- When aligning the mplifier Unit vertically with the Socket, consider the space required for the hooks and allow a leeway of about mm above and below the mplifier Unit. Hook uct or other object M Mounting screw Mounting racket Mounting base M screw (enclose) Panel PF- PF- Mounting Embedded in a Panel ()When using the Y9F- Embedded Mounting dapter, insert the mplifier Unit into a square hold in the panel, attach the dapter from the back and press in to reduce the gap with the panel. Then secure the dapter with the screws. M Mounting to the Side ()Loosen the M. cover screw and remove the cover. Loosen the M. cover screw and remove the cover, and remove the M screw. ()ttached the enclosed M screw to the cover and secure the cover to the case. ()Secure the mplifier Unit with M screws from the side. You must provide these screws. Panel Y9F- ()When using the Y9F- or Y9F- Embedded Mounting dapter, just press the mplifier into a square hole in the panel. If the panel coating is too thick and the hooks do not lock in place, spread the hooks from the back by pushing in the directions of the arrows. M. cover screw Insert the mplifier Unit and then spread the hooks. Panel Hook M Mounting screw M screw (enclose) M Mounting base M screws Insert the and then spread the hooks. fter completing adjustments, attach the enclosed caution label over the adjustment holes to prevent adjustment mistakes. O N 'T T O U H

17 E/E-H Removing the mplifier Unit When the mplifier Unit is mounted using the Y9F-, loosen the screws on the adapter, spread the hooks at the top and bottom, and remove the dapter. Using Y9F-, Y9F- Press in on the hooks with your thumb and forefinger and press forward on the mplifier Unit. Wiring Self-diagnostic Output When not using the self-diagnostic output, connect the orange wire to V or cut it and wrap it with insulation tape so that it does not come into contact with other terminals. Miscellaneous The sensor does not have a water-resistant structure. o not use it where it would be subjected to water or water vapor.

18 imensions Main Units E-R/-R E/E-H (Unit: mm) Tolerance class IT applies to dimensions in this data sheet unless otherwise specified.. dia. *. dia..-dia. coaxial cable ( Ω) with conductor (onductor cross section:. mm ), Standard length: m *E-R: iameter is.. E- E- 9. dia.. dia. M..-dia. coaxial cable ( Ω) with conductor (onductor cross section:. mm ), Standard length: m.-dia. coaxial cable ( Ω) with conductor (onductor cross section:. mm ), Standard length: m E-R E-RH* E- E-H* dia. dia. M.-dia. coaxial cable ( Ω) with conductor (onductor cross section:. mm ), Standard length: m (Material: Fluororesin)* M.-dia. coaxial cable ( Ω) with conductor (onductor cross section:. mm ), Standard length: m (Material: Fluororesin)* E- E-H* E- 9 dia. dia. M.-dia. coaxial cable ( Ω) with conductor (onductor cross section:. mm ), Standard length: m (Material: Fluororesin)*.-dia. coaxial cable ( Ω) with conductor (onductor cross section:. mm ), Standard length: m M. E-M dia. M.-dia. coaxial cable ( Ω) with conductors (onductor cross section:. mm ), Standard length: m Mounting Hole imensions Model F (mm) Model F (mm) Model F (mm) E-R +..-dia. E- +..-dia. E-.-dia E-R.-dia. E-R.-dia. E-.-dia E-.-dia. E-.-dia. E-M.-dia F

19 E/E-H mplifier Units E-GE E-GF. etection indicator (red).... pplicable Sockets (Sold Separately) PYF Hold-down lip PY- E-K (-pin) E-M (-pin). ().. etection indicator (red). Stability indicator (green).. pplicable Sockets (Sold Separately) For E-K (-pin) PF- PG- For E-M (-pin) PF- PG- E-J Mounting racket Installation Terminal (four, M.) M. etection indicator (red) aution Label (Provided) attachment location* () Two,. dia. Stability indicator (green) -dia. vinyl-insulated round cable with conductors (onductor cross section:. mm, Insulation diameter:. mm), Standard length: m Mounting racket (Iron). () M. ±. Mounting racket.±.. Two, R. R.. dia... R.. dia. -R ±. ± ±. E-JP ±. Mounting racket Installation etection indicator (red) M. Stability indicator (green) * fter completing adjustments, attach the caution label to prevent adjustment mistakes. Timer switch Mode selector Two.. dia. () Sensitivity adjuster aution Label (Provided) attachment location* Mounting racket (Iron) able* (.) R. ±.... Mounting racket (removable)* *. fter completing adjustments, attach the caution label to prevent adjustment mistakes. *. Not required when mounting to IN Track. *:.-dia. vinyl-insulated round cable with conductors (onductor cross section:. mm, Insulator diameter:. mm), Standard length: m. 9

20 E/E-H M. etection indicator (red) able length compensation switch Mode selector Mounting racket Two,. dia. Sensitivity adjuster () aution Label (Provided) attachment location* (.) R. ±. able*.... Mounting racket (removable)* *. fter completing adjustments, attach the caution label to prevent adjustment mistakes *. Not required when mounting to IN Track. *. -dia. vinyl-insulated round cable with conductors (onductor cross section:. mm, Insulator diameter:. mm), Standard length: m The cable can be extended up to m (separate metal conduit).

21 E/E-H ccessories (Order Separately) Mounting racket Mounting racket (for Unthreaded ylindrical Models) Y9E-FR (for. dia.) Y9E--FR (for. dia.) Y9E-FR R.. Y9E-FR R Front onnection Sockets PYF Two,. mounting holes Eight, M Sems screws. Terminal rrangement and Internal onnections (Top View) Mounting Hole imensions Two, M, M, or.-dia. holes max.. 9±. max.. max. 9 ±. Note: Track mounting is also possible. PF- Eight, M.. Sems screws.. Terminal rrangement and Internal onnections (Top View) Mounting Hole imensions Two,.-dia. or M holes max.. ±. Two,.-dia. holes Note: Track mounting is also possible. max.. max. PF- Eleven, M.. Sems screws.. Terminal rrangement and Internal onnections (Top View) Mounting Hole imensions Two,.-dia. mounting holes max.. ±. max. Two,.-dia. holes. max. 9 Note: Track mounting is also possible.

22 E/E-H ack onnection Sockets PG- dia. Terminal rrangement and Internal onnections (ottom View).9 PG- dia. Terminal rrangement and Internal onnections (ottom View) Embedded Mounting dapter (for E-K/E-M mplifier Unit) Y9F- Panel PG- ackmounting Socket Mounting Hole imensions R:. max Note. Suitable mounting panel thickness: to mm Note. heck the direction of the dapter, which depends on whether mplifier Units are arranged vertically or horizontally. Y9F- Panel Mounting Hole imensions PG- ackmounting Socket R:. max. dapter mounting holes: Two,.-dia. to ±. to ±. ±..9. Note: Suitable mounting panel thickness: to. mm Y9F- Panel PG- ackmounting Socket Mounting Hole imensions R:. max. +. ±. +. ± Note: Suitable mounting panel thickness: to. mm

23 Read and Understand This atalog Please read and understand this catalog before purchasing the products. Please consult your OMR representative if you have any questions or comments. Warranty and Limitations of Liability WRRNTY OMR's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMR. OMR MKES NO WRRNTY OR REPRESENTTI, EPRESS OR IMPLIE, REGRING N-INFRINGEMENT, MERHNTILITY, OR FITNESS FOR PRTIULR PURPOSE OF THE PROUTS. NY UYER OR USER KNOWLEGES THT THE UYER OR USER LE HS ETERMINE THT THE PROUTS WILL SUITLY MEET THE REQUIREMENTS OF THEIR INTENE USE. OMR ISLIMS LL OTHER WRRNTIES, EPRESS OR IMPLIE. LIMITTIS OF LIILITY OMR SHLL NOT E RESPSILE FOR SPEIL, INIRET, OR SEQUENTIL MGES, LOSS OF PROFITS OR OMMERIL LOSS IN NY WY NETE WITH THE PROUTS, WHETHER SUH LIM IS SE TRT, WRRNTY, NEGLIGENE, OR STRIT LIILITY. In no event shall the responsibility of OMR for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHLL OMR E RESPSILE FOR WRRNTY, REPIR, OR OTHER LIMS REGRING THE PROUTS UNLESS OMR'S NLYSIS FIRMS THT THE PROUTS WERE PROPERLY HNLE, STORE, INSTLLE, N MINTINE N NOT SUJET TO TMINTI, USE, MISUSE, OR INPPROPRITE MOIFITI OR REPIR. pplication onsiderations SUITILITY FOR USE OMR shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. t the customer's request, OMR will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PROUTS FOR N PPLITI INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THT THE SYSTEM S WHOLE HS EEN ESIGNE TO RESS THE RISKS, N THT THE OMR PROUTS RE PROPERLY RTE N INSTLLE FOR THE INTENE USE WITHIN THE OVERLL EQUIPMENT OR SYSTEM. PROGRMMLE PROUTS OMR shall not be responsible for the user's programming of a programmable product, or any consequence thereof. isclaimers HNGE IN SPEIFITIS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMR representative at any time to confirm actual specifications of purchased products. IMENSIS N WEIGHTS imensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMNE T Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMR s test conditions, and the users must correlate it to actual application requirements. ctual performance is subject to the OMR Warranty and Limitations of Liability. ERRORS N OMISSIS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. OMR orporation Industrial utomation ompany In the interest of product improvement, specifications are subject to change without notice. (c)opyright OMR orporation ll Right Reserved.

E2C/E2C-H. Separate Amplifier Sensor with Sensitivity Adjustment. Separate Amplifier Proximity Sensor with Adjustment Potentiometer

E2C/E2C-H. Separate Amplifier Sensor with Sensitivity Adjustment. Separate Amplifier Proximity Sensor with Adjustment Potentiometer Separate mplifier Proximity Sensor with djustment Potentiometer E/E-H Separate mplifier Sensor with Sensitivity djustment ompact design with smaller Sensor Head. Heat-resistance model available for application

More information

E2E2. Proximity Sensor with a Long Screw Length. Long-barrel Inductive Proximity Sensor. Ordering Information. Sensors DC 2-Wire Models

E2E2. Proximity Sensor with a Long Screw Length. Long-barrel Inductive Proximity Sensor. Ordering Information. Sensors DC 2-Wire Models Long-barrel Inductive Proximity Sensor EE CSM_EE_DS_E Proximity Sensor with a Long Screw Length Increased tightening strength. Cable protectors provided as a standard feature. Increased indicator visibility.

More information

E2E2. Proximity Sensor with a Long Screw Length. Long-barrel Inductive Proximity Sensor. Ordering Information. Sensors DC 2-Wire Models

E2E2. Proximity Sensor with a Long Screw Length. Long-barrel Inductive Proximity Sensor. Ordering Information. Sensors DC 2-Wire Models Long-barrel Inductive Proximity Sensor EE CSM_EE_DS_E Proximity Sensor with a Long Screw Length Increased tightening strength. Cable protectors provided as a standard feature. Increased indicator visibility.

More information

E2E2. Proximity Sensor with a Long Screw Length. Long-barrel Inductive Proximity Sensor. Ordering Information. Sensors DC 2-Wire Models

E2E2. Proximity Sensor with a Long Screw Length. Long-barrel Inductive Proximity Sensor. Ordering Information. Sensors DC 2-Wire Models Long-barrel Inductive Proximity Sensor E2E2 Proximity Sensor with a Long Screw Length Increased tightening strength. Cable protectors provided as a standard feature. Increased indicator visibility. A milled

More information

Digital display Pressure range ON/OFF output Linear output Model

Digital display Pressure range ON/OFF output Linear output Model Slim Digital Pressure Sensor E8CC with Built-in Microcomputer and Digital Display Withstands a pressure of 49 kpa and highly reliable. Incorporates a two-turn pressure adjuster ensuring easy pressure setting.

More information

TL-W. Standard Flat Sensors in Many Different Variations. Flat Inductive Proximity Sensor. Ordering Information

TL-W. Standard Flat Sensors in Many Different Variations. Flat Inductive Proximity Sensor. Ordering Information Flat Inductive Standard Flat s in Many Different Variations Only 6 mm thick yet provides a sensing distance of mm (MC1). Aluminum die-cast models also available. Be sure to read Safety Precautions on page

More information

Inductive Proximity Sensor

Inductive Proximity Sensor Inductive Proximity Sensor Variable Distance and Differential Travel Allow a Wide Range of Applications Various Heads available in outer diametersfrom2.0to40mm. and stability indicators (LED) in Amplifier

More information

E2EZ-X2D1-N E2EZ-X2D2-N

E2EZ-X2D1-N E2EZ-X2D2-N Chip-immune Inductive s Detects Objects without Being Influenced by Aluminum or Iron Chips Series now includes M s. s also available. CE Marking for DC -Wire and DC -Wire s. Be sure to read Safety Precautions

More information

Dimension A. Dimension B

Dimension A. Dimension B Slim Connector-Terminal lock Conversion Units CSM DS_E_2_2 New Slim Connector-Terminal lock Conversion Units. Mounting area reduced by 35% (in comparison with 40-pole XW2 Units) to contribute to downsizing

More information

DC2-Wire Cylindrical Long-Distance No-Polarity Proximity Switches

DC2-Wire Cylindrical Long-Distance No-Polarity Proximity Switches D-Wire ylindrical Long-Distance No-Polarity Proximity Switches FL7M Series Rigid structure reduces damage from collision with workpiece. Long sensing distance (M: mm, M: mm, M: 5 mm) D -wire switch with

More information

D2VW. Sealed Miniature Basic Switch Conforms to IP67 (Excluding the terminals on terminal models) Model Number Legend. Sealed Miniature Basic Switch

D2VW. Sealed Miniature Basic Switch Conforms to IP67 (Excluding the terminals on terminal models) Model Number Legend. Sealed Miniature Basic Switch Sealed Miniature Basic Switch Conforms to IP67 (Excluding the terminals on terminal models) Use of epoxy resin assures stable sealing, making this switch ideal for places subject to water spray or excessive

More information

A165S/W. Separate Construction with Cylindrical 16-dia. Body. Knob-type Selector Switch (Detachable) (Cylindrical 16-dia.

A165S/W. Separate Construction with Cylindrical 16-dia. Body. Knob-type Selector Switch (Detachable) (Cylindrical 16-dia. Knob-type Selector Switch (Detachable) (Cylindrical 16-dia.) CSM_A165S_W_DS_E_4_1 Separate Construction with Cylindrical 16-dia. Body Same separate construction as the A16-series Pushbuttons with Miniature

More information

2.5mm. Output configuration NPN. 2.5mm PNP. 2.5mm

2.5mm. Output configuration NPN. 2.5mm PNP. 2.5mm Compact Square Inductive Proximity Sensor World s Smallest Square Sensor with uilt -in Amplifier 5.5 x 5.5 mm type contributes to smaller, space-- saving machines and devices. Comprehensive range; sensing

More information

Multiple Limit Switch

Multiple Limit Switch Multiple Limit Switch CSM DS_E_1_1 A New Monoblock Multiple Limit Switch Incorporating a ead Box with a Tough ead and Ensuring igh Sealing Performance and a Mechanical Durability of 5,000,000 Operations

More information

M2S. Indicator Series with Square 40-mm Body. Indicator (Square) List of Models

M2S. Indicator Series with Square 40-mm Body. Indicator (Square) List of Models Indicator (Square) CSM DS_E_3_2 Indicator Series with Square 40-mm Body Same type of Indicator as those in the A3S-series Pushbutton Switch Easy panel mounting from the front and simple lamp replacement

More information

E2EM-X4X1 2M * E2EM-X4X2 2M Shielded E2EM-X8X1 2M * E2EM-X8X2 2M. M30 15 mm E2EM-X15C1 2M E2EM-X15C2 2M. M18 16 mm E2EM-X16MX1 2M E2EM-X16MX2 2M

E2EM-X4X1 2M * E2EM-X4X2 2M Shielded E2EM-X8X1 2M * E2EM-X8X2 2M. M30 15 mm E2EM-X15C1 2M E2EM-X15C2 2M. M18 16 mm E2EM-X16MX1 2M E2EM-X16MX2 2M Long-istance Proximity Sensor EEM CSM_EEM_DS_E_6_ Long-istance Proximity Sensor Long-istance etection at up to mm enables secure mounting with reuce problems ue to workpiece collisions. No polarity for

More information

ccessories (sold separately) Name ppearance O.D. Mounting bracket Protective cover Spatter-guarded protective cover For M12 For M18 For M30 For M12 Fo

ccessories (sold separately) Name ppearance O.D. Mounting bracket Protective cover Spatter-guarded protective cover For M12 For M18 For M30 For M12 Fo D3-Wire ylindrical Proximity Switches Model FL7M Extensive lineup includes M8 to M30 sizes, with NPN and PNP output models available for each. ompact size saves space Indicator lamp can be checked even

More information

Small-diameter Proximity Sensor

Small-diameter Proximity Sensor Small-diameter Proximity Sensor EE Ultra small size, but surprisingly easy installation! With the addition of M, 5.-dia.,.5-dia. size, unshielded, pre-wired connector model, and connector model, a total

More information

Various applications. Robust housing. The GX-4S uses a robust stainless steel housing. The tightening torque can be 0.58 N m or less.

Various applications. Robust housing. The GX-4S uses a robust stainless steel housing. The tightening torque can be 0.58 N m or less. INUCTIVE SERIES Compact Inductive Proximity Sensor Flexible cable Metal embedding type available possible Amplifier Built-in High functionality together with robust housing and flexible cable GA-/GH -N

More information

E2Q6. Rectangular Proximity Sensor. Freely Change the Sensing Direction. Ordering Information. Sensors [Refer to Dimensions on page 6] DC Models

E2Q6. Rectangular Proximity Sensor. Freely Change the Sensing Direction. Ordering Information. Sensors [Refer to Dimensions on page 6] DC Models Rectangular Freely Change the Sensing Direction Change between any of five sensing directions: front or 9 up, down, left, or right. Four indicators show the operating status of the from many directions.

More information

G3PE-Single-phase. Solid State Relays for Heaters

G3PE-Single-phase. Solid State Relays for Heaters Solid State Relays for Heaters Single-phase CSM_Single-phase_DS_E Compact, Slim-profile SSRs with Heat Sinks. s with No Zero Cross for a Wide Range of Applications. RoHS compliant. s also available with

More information

2NC (slow-action) Direct. Model. opening

2NC (slow-action) Direct. Model. opening Small Safety Limit Switch CSM DS_E_3_1 Smallest Class of Safety Limit Switches in the World Note: Contact your sales representative for details on models with safety standard certification. The world's

More information

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h) Mechatronic Analog Timer H3AM Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Refer to Warranty and

More information

2.5 mm. (0.10 in) E2S -Q25 E2S -Q26. Output configuration. 2.5 mm. End face E2S -W15 E2S -W16 End face PNP

2.5 mm. (0.10 in) E2S -Q25 E2S -Q26. Output configuration. 2.5 mm. End face E2S -W15 E2S -W16 End face PNP Subminiature Rectangular Inductive Prox World s Smallest Square Sensor with Built-in Amplifier H. x. mm type allows smaller, space-saving machines and devices H High response frequency ( khz) for fast

More information

Inductive Proximity Sensor

Inductive Proximity Sensor Inductive Proximity Sensor Subminiature Sensor Ideal for Narrow Mounting Space Grooved TL-G3D is ideal for high-speed pulse generator and high-speed revolution control. TL-Q2 and TL-Q5 save mounting space

More information

DC2-Wire Spatter-Guarded Cylindrical Proximity Sensors. Operation mode N.O. N.C. N.O. N.C. N.O. N.C. 10mm

DC2-Wire Spatter-Guarded Cylindrical Proximity Sensors. Operation mode N.O. N.C. N.O. N.C. N.O. N.C. 10mm D-Wire Spatter-Guarded ylindrical Proximity Sensors FL7MSeries variety of anti-spatter measures make these sensors the optimum for welding processes on the automotive production line. With Teflon coating

More information

Cylindrical photoelectric sensors in M18 plastic or brass housings. Performance and portfolio variety. Metal *1 90 Optics AC power supply *2

Cylindrical photoelectric sensors in M18 plastic or brass housings. Performance and portfolio variety. Metal *1 90 Optics AC power supply *2 Cylindrical photoelectric sensors in M8 plastic or brass housings Complete sensor portfolio in plastic and metal housing IP67, IP69K for highest water resistance High immunity against electro-magnetic

More information

D2MV. Highly reliable Miniature Basic Switch in spite of its Ultra-low Load action. Model Number Legend. List of Models.

D2MV. Highly reliable Miniature Basic Switch in spite of its Ultra-low Load action. Model Number Legend. List of Models. Highly reliable iniature Basic Switch in spite of its Ultra-low Load action Twin crossbar contact employed for exceptionally high contact reliability. Unique internal mechanism that ensures high contact

More information

Supply voltage 12 to 24 VDC (10 to 30 VDC), ripple (p-p) 10% max. 100 to 220 VAC (90 to 250 VAC), 50/60 Hz

Supply voltage 12 to 24 VDC (10 to 30 VDC), ripple (p-p) 10% max. 100 to 220 VAC (90 to 250 VAC), 50/60 Hz R Pancake Style Inductive Prox Long-Range Proximity Sensor Detects Metal Objects at 50 mm H Ideal for many industrial automation applications H Choose DC 3 -wire or AC 2 -wire models H Rugged die -cast

More information

Operation Key D4BS - K Head Mounting Direction F: Four mounting directions possible (front-side mounting at shipping)

Operation Key D4BS - K Head Mounting Direction F: Four mounting directions possible (front-side mounting at shipping) Safety-door Switch D4BS The Special Activates a Direct Opening Mechanism to Open the Contacts and Shut Off Control Circuits when Protective Doors Are Opened on Machine Tools or Other Equipment CSM_D4BS_DS_E_6_1

More information

E2K-L. Liquid Level Sensor. Applications. Ordering Information

E2K-L. Liquid Level Sensor. Applications. Ordering Information Liquid Level Sensor Installation on pipes. Sensing by means electrostatic capacity and is not influenced by the color of the pipe or liquid. Available in 8 to mm dia. and to mm dia. models to enable sensing

More information

DC2-Wire Regular Cylindrical Proximity Switches

DC2-Wire Regular Cylindrical Proximity Switches DC-Wire Regular Cylindrical Proximity Switches FL7M Series Rigid structure, highly waterproof DC -wire switches with improved visibility of lamps. DC -wire, for reduced wiring costs. Stable sensing area

More information

GX-5SU(B) is just 5.4 mm 0.213in in diameter, the smallest in existing DC two-wire sensors. It saves you space.

GX-5SU(B) is just 5.4 mm 0.213in in diameter, the smallest in existing DC two-wire sensors. It saves you space. DC 2-wire Cylindrical Inductive Proximity SERIES High performance & ease of use Amplifier Built-in Robust in tightening The tightening torque has been improved to approx. four times greater than that of

More information

D4NS. Safety-door Switch. Multi-contact, Labor-saving, Environment-friendly, Next-generation Safety-door Switch. Model Number Structure

D4NS. Safety-door Switch. Multi-contact, Labor-saving, Environment-friendly, Next-generation Safety-door Switch. Model Number Structure Safety-door Switch D4NS CSM_D4NS_DS_E_5_2 Multi-contact, Labor-saving, Environment-friendly, Next-generation Safety-door Switch Lineup includes three contact models with 2NC/1NO and 3NC contact forms and

More information

Model Number Structure

Model Number Structure Solid State Relays CSM OEE_DS_E_1_2 Extremely Thin Relays Integrated with Heat Sinks Downsizing achieved through optimum design of heat sink. Mounting possible via screws or via DIN track. Close mounting

More information

TL-N7MD1 7mm(0.28 in) NC. 12 mm (0.47 in)

TL-N7MD1 7mm(0.28 in) NC. 12 mm (0.47 in) R Rectangular Inductive Prox Space-Saving Sensors for a Wide Range of Applications H Switches loads up to 200 ma H Easy to install DC 2-wire models reduce wiring H DC 3-wire models available with high-flexibility

More information

Model Pressure range ON/OFF output Linear output

Model Pressure range ON/OFF output Linear output Digital Sensor Sensor with Easy-to-Read LED Display status can be checked at a glance from the red digital pressure value and analog bar displays. Measurement pressure is averaged by the chattering prevention

More information

Correction Reissue. Product Discontinuation Notices. Discontinuation Notice of Cylindrical Proximity Sensor Model E2E series.

Correction Reissue. Product Discontinuation Notices. Discontinuation Notice of Cylindrical Proximity Sensor Model E2E series. PRODUCT NEWS Correction Reissue Product Discontinuation Notices Proximity Sensors Issue Date August 4, 2014 No. 2014038CE(3) Discontinuation Notice of Cylindrical Proximity Sensor Model E2E series.

More information

Compact Inductive Proximity Sensor. onlinecomponents.com. Various Applications

Compact Inductive Proximity Sensor. onlinecomponents.com. Various Applications INUCTIVE SERIES Compact Inductive Proximity -N -U G-8H/8H G-N G-8U G-6 Miniature -S is an amplifier built-in inductive proximity sensor having a diameter of just ".8mm. -S ".8mm Various Applications The

More information

D4BS CSM_D4BS_DS_E_8_4

D4BS CSM_D4BS_DS_E_8_4 Safety-door Switch CSM DS_E_8_4 The Special Activates a Direct Opening Mechanism to Open the Contacts and Shut Off Control Circuits when Protective Doors Are Opened on Machine Tools or Other Equipment

More information

Inductive Proximity Sensor

Inductive Proximity Sensor Inductive Proximity Sensor General-purpose Type in a Basic Switch Housing Mounting pitch compatible with that of mechanical basic switch. Wide operating voltage range: 10 to 30 VDC or 90 to 250 VAC. LED

More information

A165E CSM_A165E_DS_E_11_2

A165E CSM_A165E_DS_E_11_2 Emergency Stop Switch (16-dia.) CSM DS_E_11_2 Separate Construction with Minimal Depth Direct opening mechanism to open contacts in emergencies, such as when they are welded. Conforms to EN 6947-5-5. Includes

More information

Digital display Pressure range ON/OFF output Linear output Model

Digital display Pressure range ON/OFF output Linear output Model Slim Digital Pressure Sensor E8CB/ CSM_E8CB DS_E 1 with Built-in Microcomputer and Digital Display Withstands a of 9 kpa and highly reliable. Incorporates a two-turn adjuster ensuring easy setting. Be

More information

GL-6 SERIES. Miniature Inductive Proximity Sensor. High Performance in Surprisingly Small Body. Marked. Extremely Small.

GL-6 SERIES. Miniature Inductive Proximity Sensor. High Performance in Surprisingly Small Body. Marked. Extremely Small. G- SERIES Miniature Inductive Proximity Sensor High Performance in Surprisingly Small Body Marked Conforming to EMC Directive Extremely Small Mountable in a tight space as the sensor is just 19mm in volume.

More information

How to Order 1 T Z A. r Pressure range. 05 Pressure range 0 to 0.5 MPa 10 Pressure range 0 to 1 MPa 16 Pressure range 0 to 1.6 MPa

How to Order 1 T Z A. r Pressure range. 05 Pressure range 0 to 0.5 MPa 10 Pressure range 0 to 1 MPa 16 Pressure range 0 to 1.6 MPa oolant Valve Series S External pilot solenoid S ir operated S How to Order 0 0 Y 0 0 T Z q w e r t y u i o!0!!!!! q Series S00 S00 S00 w Valve type ormally closed ormally open e Seal material R FKM r Pressure

More information

Proximity Sensor. Shield Size Sensing distance Output configuration Models Shielded M12 3 mm NO E2EQ-X3D1 E2EQ-X7D1 M30 10 mm E2EQ-X10D1

Proximity Sensor. Shield Size Sensing distance Output configuration Models Shielded M12 3 mm NO E2EQ-X3D1 E2EQ-X7D1 M30 10 mm E2EQ-X10D1 Proximity Sensor A Series of Spatter-preventing Proximity Sensors with a Teflon-coated Metal Housing Teflon*-coated metal housing endures high tightening torque. Pre-wired and plug-in models are available.

More information

A Metal Head That's. Highly Durable and Provides Long-distance Detection. mm 7(M18 Model) Proximity Sensor with All-stainless Housing E2EF NEW

A Metal Head That's. Highly Durable and Provides Long-distance Detection. mm 7(M18 Model) Proximity Sensor with All-stainless Housing E2EF NEW NEW Proximity Sensor with All-stainless Housing EEF Standard Model (Completely stainless- housing) A Metal Head That's * Highly Durable and Provides Long-distance Detection mm 7(M18 Model) *More than 0

More information

D2SW. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

D2SW. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend ealed ubminiature Basic witch ealed ubminiature Basic witch Conforming to IP67 (Excluding the terminals on terminal ) Use of epoxy resin assures stable sealing, making this switch ideal for places subject

More information

D4GS-N CSM_D4GS-N_DS_E_7_2

D4GS-N CSM_D4GS-N_DS_E_7_2 Slim Safety Door Switch D4GS-N CSM_D4GS-N_DS_E_7_2 Slim Safety Door Switches with IP67 Rating Slim design with a width of only 17 mm (three-contact models). Reversible design allowing either front or rear

More information

Ordering Information. Specifications. Motor Time Switch H2F-WM. Accessories (Order Separately) Time Specifications. Ratings

Ordering Information. Specifications. Motor Time Switch H2F-WM. Accessories (Order Separately) Time Specifications. Ratings Motor Time Switch H2F-WM CSM_H2F-WM_DS_E_2_1 Weekly ON/OFF Control in 1-h Increments The H2F-WM is a Compact Weekly Time Switch in a DIN -mm Body Equipped with Power Interruption Backup Providing Protection

More information

D2SW. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

D2SW. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend ealed ubminiature Basic witch ealed ubminiature Basic witch Conforming to IP67 (Excluding the terminals on terminal ) Use of epoxy resin assures stable sealing, making this switch ideal for places subject

More information

Tina 11A Connection block

Tina 11A Connection block Original instructions Tina 11A Connection block ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this

More information

D2D. Door Interlock Power Switch with Minimum Contact gap of 3 mm. Model Number Legend. Contact Form. List of Models. Contact Specifications.

D2D. Door Interlock Power Switch with Minimum Contact gap of 3 mm. Model Number Legend. Contact Form. List of Models. Contact Specifications. Power/oor Switch oor Interlock Power Switch with Minimum Contact gap of mm Offers the minimum contact gap of mm required for power switches as standard equipment. Safety considerations include a double

More information

Input terminals Isolation method Zero cross function Operation indicator Alarm output Applicable load (See note.) Model

Input terminals Isolation method Zero cross function Operation indicator Alarm output Applicable load (See note.) Model Solid State Relays with Built-in Current Transformer CSM DS_E_7_ A New-concept SSR with Built-in Current Transformer. Heater Burnout and SSR Shortcircuit Failure Detection. Built-in Current Transformer

More information

Anti-spatter Inductive Prox E2EQ. Ordering Information. Weld-Sputter Resistant DC 2-Wire Cylindrical Sensors. H Rugged fluoroplastic coated brass

Anti-spatter Inductive Prox E2EQ. Ordering Information. Weld-Sputter Resistant DC 2-Wire Cylindrical Sensors. H Rugged fluoroplastic coated brass R Anti-spatter Inductive Prox Weld-Sputter Resistant DC 2-Wire Cylindrical Sensors H Rugged fluoroplastic coated brass barrel withstands high tightening torque H Fluoroplastic resin face prevents weld

More information

High Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67G environment resistance

High Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67G environment resistance 11 High Accuracy ddy Current Type Sensor SRIS Related Information General terms and conditions... F-7 Glossary of terms... P.1493 Sensor selection guide... P.1055~ General precautions... P.1501 PHOTO PHOTO

More information

Ratings 1 A at 125 VAC 1 A at 30 VDC LED indicator Without indicator With indicator Without indicator With indicator Actuator

Ratings 1 A at 125 VAC 1 A at 30 VDC LED indicator Without indicator With indicator Without indicator With indicator Actuator Miniature Limit Switch CSM DS_E_3_3 Many Models Including Roller Lever Switches are Only -mm Thick with Connector New center roller lever models that enable ganged mounting of up to 6 Switches. Cable connectors

More information

Smile 11 RA/-B Smile 12 RF/-G Reset button

Smile 11 RA/-B Smile 12 RF/-G Reset button Original Instructions Smile 11 RA/-B Smile 12 RF/-G Reset button ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this User Manual Please read

More information

Tina 10A/B/C Adaptor unit

Tina 10A/B/C Adaptor unit Original instructions Tina 10A/B/C Adaptor unit ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this

More information

Model Pressure range ON/OFF output Linear output

Model Pressure range ON/OFF output Linear output Authorised Distributors:- ASH & ALAIN INDIA PV LD S-1, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-112(India) el : 11-43797575 Fax : 11-43797574 E-mail : sales@ashalain.com Digital Sensor Sensor

More information

FMC-1/2 Tina Muting unit

FMC-1/2 Tina Muting unit Original instructions FMC-1/2 Tina Muting unit ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this

More information

* E8MS-N1 is only 1-channel pressure sensor controller. E80-C2 can be used. For more details, please refer to E80 catalogue.

* E8MS-N1 is only 1-channel pressure sensor controller. E80-C2 can be used. For more details, please refer to E80 catalogue. Authorised Distributors:- ASH & ALAIN INDIA PVT LTD S-, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-(India) Tel : -7977 Fax : -7977 E-mail : sales@ashalain.com Sensor Four-Input-Channel Sensor

More information

GH-5S. 5.6 times approx. Tightening torque 0.78N m or less. Disconnection Alarm Indicator

GH-5S. 5.6 times approx. Tightening torque 0.78N m or less. Disconnection Alarm Indicator GA- SERIES Amplifier-separated Micro-size Inductive Proximity Sensor GH SERIES -N -U Slim & Small The amplifier is extremely slim, just mm thick. This results in a compact size even if several amplifiers

More information

(3) Terminals. 00: AC connector. Comparison of New and Old Molded Terminal Models. Model Location of lead outlet

(3) Terminals. 00: AC connector. Comparison of New and Old Molded Terminal Models. Model Location of lead outlet Small Sealed Switch D4E-N CSM_D4E-_N_DS_E_4_ Slim and Compact Switch with Better Seal and Ensuring Longer Service Life than D4E Flat springs with an improved lever ratio of the built-in switch ensure smooth

More information

Proximity Sensors E-1. Standard E2E/E2EG E-2 Antispatter E2EQ E-32 Chemical Resistance E2FQ E-40. Cylindrical

Proximity Sensors E-1. Standard E2E/E2EG E-2 Antispatter E2EQ E-32 Chemical Resistance E2FQ E-40. Cylindrical Proximity Sensors Cylindrical Standard EE/EEG E- Antispatter EEQ E- Chemical Resistance EFQ E-0 Rectangular Subminiature ES E- Flat TL-W E-5 Standard TL-N E-60 Capacitive Liquid Level EK-L E-68 Long Distance

More information

D4BL. Guard Lock Safety-door Switch

D4BL. Guard Lock Safety-door Switch Guard Lock Safety-door Switch D4BL CSM_D4BL_DS_E_5_1 Release Protective Cover Locks Using Controller Signals or Pushbutton Switches after the Cutting Tool Stops Moving Due to Inertia A mechanical lock

More information

Model Number Legend (Completely Assembled)... Shipped as a set which includes the Operation Unit, Lamp (lighted models only), and Switch. 4.

Model Number Legend (Completely Assembled)... Shipped as a set which includes the Operation Unit, Lamp (lighted models only), and Switch. 4. Emergency Stop Switch (-dia./5-dia.) AE CSM_AE_DS_E_7_ Install in -dia. or 5-dia. Panel Cutout Direct opening mechanism to open the circuit when the contact welds. Safety lock mechanism prevents operating

More information

Basic Switch Style Inductive Prox TL-M. Ordering Information. General-purpose Inductive Prox in a Basic Switch Housing

Basic Switch Style Inductive Prox TL-M. Ordering Information. General-purpose Inductive Prox in a Basic Switch Housing R Basic Switch Style Inductive Prox General-purpose Inductive Prox in a Basic Switch Housing H Mounting pitch compatible with that of a mechanical basic switch H Wide operating voltage range: 10 to 30

More information

Description General-purpose models Timer-function models Output NPN PNP NPN PNP Part number E3X-NH11 E3X-NH41 E3X-NH21 E3X-NH51 Appearance

Description General-purpose models Timer-function models Output NPN PNP NPN PNP Part number E3X-NH11 E3X-NH41 E3X-NH21 E3X-NH51 Appearance R High-Precision Fiber-optic Amplifier TheEmploysa16-Bit Processor as An Industry First H An Automatic Sensitivity Adjustment feature allows stable detection of objects in frequently changing environments

More information

Sensing & Safety GENERAL CATALOGUE 2004/2005

Sensing & Safety GENERAL CATALOGUE 2004/2005 GENERAL CATALOGUE 00/005 Sensing & Safety Photoelectric Sensors Displacement Sensors Vision Systems Safety Sensors Safety Switches Safety Relays Proximity Sensors Rotary Encoders Pressure Sensors Advanced

More information

GX-5SU(B) is just 5.4mm in diameter, the smallest in existing DC two-wire sensors. It saves you space. GX-12ML(B) Conventional model

GX-5SU(B) is just 5.4mm in diameter, the smallest in existing DC two-wire sensors. It saves you space. GX-12ML(B) Conventional model SERIES DC -wire Cylindrical Inductive Proximity High Performance & Ease of Use Marked Conforming to EMC Directive Robust in Tightening The tightening torque has been improved to approx. four times greater

More information

Compact Size: "5.4mm. GX-5SU(B) is just 5.4mm in diameter, the smallest in existing DC two-wire sensors. It saves you space.

Compact Size: 5.4mm. GX-5SU(B) is just 5.4mm in diameter, the smallest in existing DC two-wire sensors. It saves you space. INDUCTIVE SERIES DC -wire Cylindrical Inductive Proximity G-8H/8H G-N G-8U G-6 Robust in Tightening The tightening torque has been improved to approx. four times greater than that of conventional models

More information

Better Productivity by Standstill and Low-speed Monitoring

Better Productivity by Standstill and Low-speed Monitoring Better Productivity by Standstill and Low-speed Monitoring Standstill Monitoring Reduces Extra Waiting Time During Work Problem When a hazardous part has a long inertia, door-lock control using an off-delay

More information

EZ-LIGHT Indicators 4-Color, Multi-Function

EZ-LIGHT Indicators 4-Color, Multi-Function EZ-LIGHT Indicators -olor, Multi-Function Datasheet D-Operated Indicators with olors and Multiple Flashing Frequencies Rugged, cost-effective. and easy-to-install indicators available in K0, K0 Flat Pack,

More information

WL50S High-Intensity Work Spot Light

WL50S High-Intensity Work Spot Light Datasheet General-purpose LED work lighting For the latest technical information about this product, including specifications, dimensions, and wiring, see www.bannerengineering.com. Three lens options,

More information

Features. 2-wire type available. Max. operation distance: 1.5 mm 0.06 in (Stable sensing range 0 to 1.2 mm 0.05 in)

Features. 2-wire type available. Max. operation distance: 1.5 mm 0.06 in (Stable sensing range 0 to 1.2 mm 0.05 in) 817 Cylindrical Inductive Proximity Sensor SERIES Related Information General terms and conditions... F-3 Glossary of terms...p.1576~ guide... P.781~ General precautions... P.1579~ PHOTO PHOTO panasonic.net/id/pidsx/global

More information

PCB Terminal Blocks: Push-in SMT Terminals with 2.54mm Pitch

PCB Terminal Blocks: Push-in SMT Terminals with 2.54mm Pitch New Product XW4H/XW4K/XW4 P Terminal locks: Push-in SMT Terminals with mm Pitch Push-in Terminals to Easily omplete onnections. P Terminal locks with mm Pitch. Push-in connection method allows repeated

More information

Tina 4A Connection block

Tina 4A Connection block Original instructions Tina 4A Connection block Instructions valid for versions of the product from ver. H ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read

More information

D4BL. Guard Lock Safety-door Switch

D4BL. Guard Lock Safety-door Switch Guard Lock Safety-door Switch D4BL CSM_D4BL_DS_E_7_1 Release Protective Cover Locks Using Controller Signals or Pushbutton Switches after the Cutting Tool Stops Moving Due to Inertia A mechanical lock

More information

Rectangular-shaped Inductive Proximity Sensor.

Rectangular-shaped Inductive Proximity Sensor. 69 PHOTO PHOTO Rectangular-shaped Inductive Proximity Sensor -F/H SERIES Related Information Amplifi er General terms and conditions... P.1 Sensor selection guide...p.11~ / P.67~ Glossary of terms... P.19

More information

Features. Emergency Stop Switch A165E. Separate Construction with Smallest Class of Depth in the World. Safety Lock Prevents Misuse

Features. Emergency Stop Switch A165E. Separate Construction with Smallest Class of Depth in the World. Safety Lock Prevents Misuse Emergency Stop Switch Separate Construction with Smallest Class of Depth in the World Direct opening mechanism to open contacts in emergencies, such as when they are welded. Conforms to EN418. Includes

More information

E2E/E2EQ NEXT Series. Proximity Sensor. Long-distance Detection Prevents Unexpected Facility Stoppages. E2E/E2EQ NEXT Series Model Number Legend

E2E/E2EQ NEXT Series. Proximity Sensor. Long-distance Detection Prevents Unexpected Facility Stoppages. E2E/E2EQ NEXT Series Model Number Legend Proximity Sensor Long-distance Detection Prevents Unexpected Facility Stoppages The world's longest sensing distance* Nearly double the sensing distance of previous With high-brightness LED, the indicator

More information

GXL SERIES. High performance in micro-size design. Micro-size Inductive Proximity Sensor PROXIMITY SENSORS INDUCTIVE. Wide model variety

GXL SERIES. High performance in micro-size design. Micro-size Inductive Proximity Sensor PROXIMITY SENSORS INDUCTIVE. Wide model variety SERIES Micro-size Inductive Proximity -wire available PNP output Oil resistant Flexible cable Different freq. available available available Amplifier Built-in High performance in micro-size design GA-/GH

More information

Cylindrical Sensors CY-100 SERIES panasonic-electric-works.net/sunx. Cylindrical Inductive Proximity Sensor GX-M SERIES.

Cylindrical Sensors CY-100 SERIES panasonic-electric-works.net/sunx. Cylindrical Inductive Proximity Sensor GX-M SERIES. Cylindrical Sensors Photoelectric Sensor CY-100 SERIES Inductive Proximity Sensor GX-M SERIES Listing (2 m cable length type only) Cylindrical Inductive Proximity Sensor GX-M SERIES Cylindrical Photoelectric

More information

Sense7-series Non-contact coded safety switch

Sense7-series Non-contact coded safety switch Original instructions Sense7-series Non-contact coded safety switch ABB AB / Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please

More information

XW2R-COM. Common Terminals X W 2R - P D - COM. Space-saving and less wiring work of power supply wiring are achieved. Application Example

XW2R-COM. Common Terminals X W 2R - P D - COM. Space-saving and less wiring work of power supply wiring are achieved. Application Example Common Terminals XW2R-COM CSM_XW2R-P_M_B-COM_DS_E Space-saving and less wiring work of power supply wiring are achieved. Common wiring is already wired on the PCB, transition wiring is unnecessary. Wiring

More information

Smile 41 Push-button box with/without emergency stop

Smile 41 Push-button box with/without emergency stop Original instructions Smile 41 Push-button box with/without emergency stop ABB Jokab Safety Varlabergsvägen 11, 434 39 Kungsbacka www.abb.com/jokabsafety Read and understand this document Please read and

More information

DC2-Wire Spatter-Guarded Cylindrical Proximity Switches

DC2-Wire Spatter-Guarded Cylindrical Proximity Switches DC-Wire Spatter-Guarded Cylindrical Proximity Switches FL7M Series A variety of anti-spatter measures make these switches the optimum for welding processes on the automotive production line. With Teflon

More information

EStrong-series Emergency Stop

EStrong-series Emergency Stop Original instructions EStrong-series Emergency Stop ABB AB / Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand

More information

Safety Limit Switch

Safety Limit Switch Safety Limit Switch D4B-@N CSM_D4B-_N_DS_E_4_1 Snap-action contact with certified direct operation certification. Maintenance, seal, and resistance to shock increased and direct mechanism added. Three-conduit

More information

Ordering Information. Long Barrel Inductive Prox. E2E2 2-Wire DC. Reduce Wiring to Control Devices with 2-Wire Inductive Prox Sensors

Ordering Information. Long Barrel Inductive Prox. E2E2 2-Wire DC. Reduce Wiring to Control Devices with 2-Wire Inductive Prox Sensors R Long Barrel Inductive Prox E2E2 2-Wire DC Reduce Wiring to Control Devices with 2-Wire Inductive Prox Sensors H Thick nickel-plated brass barrel for ruggedness H Solid potted internal circuitry withstands

More information

Compact Size: "5.4mm. GX-5SU(B) is just 5.4mm in diameter, the smallest in existing DC two-wire sensors. It saves you space.

Compact Size: 5.4mm. GX-5SU(B) is just 5.4mm in diameter, the smallest in existing DC two-wire sensors. It saves you space. SERIES DC -wire Cylindrical Inductive Proximity High Performance & Ease of Use Marked Conforming to EMC Directive Robust in Tightening The tightening torque has been improved to approx. four times greater

More information

PCB Terminal Blocks: Push-in SMT Terminals with 2.54mm Pitch

PCB Terminal Blocks: Push-in SMT Terminals with 2.54mm Pitch XW4H/XW4K/XW4 P Terminal locks: Push-in SMT Terminals with mm Pitch Push-in Terminals to Easily omplete onnections. P Terminal locks with mm Pitch. Push-in connection method allows repeated repairs. Hold-down

More information

EZ-LIGHT Indicators Audible

EZ-LIGHT Indicators Audible EZ-LIGHT Indicators udible Datasheet For the latest technical information about this product, including specifications, dimensions, and wiring, see www.bannerengineering.com. QPM EURO-STYLE PIGTIL PUR

More information

Safety Guard Switching Unit G9SX-GS

Safety Guard Switching Unit G9SX-GS Enabling Grip Switch CSM DS_E_5_1 Enabling Grip Switch with Distinct Feel for Three Easily Discernible Positions The difficult task of configuring safety circuits is now easily achieved by combining the

More information

Cylindrical Inductive Proximity Sensor GX-M SERIES

Cylindrical Inductive Proximity Sensor GX-M SERIES Cylindrical Inductive Proximity Sensor GX-M SERIES Listing (2 m cable length type only) Features Wide product range Types: DC 3-wire shielded type DC 3-wire non-shielded type DC 2-wire standard type DC

More information

Sensing distance. 4mm. 4mm. 7mm. 12mm. 20mm

Sensing distance. 4mm. 4mm. 7mm. 12mm. 20mm DC2-wire Square Proximity Sensors FL2R/SSeries This DC2-wire Square Proximity sensor Can Be Directly Connected to Programmable Controllers and Units. Wide Range of Models Available. Reduced wiring costs

More information

Non-Contact Sensor for Workpiece Placement Verification

Non-Contact Sensor for Workpiece Placement Verification ir Catch Sensor Series 2 Non-Contact Sensor for Workpiece Placement Verification Stable detection of. to. mm clearance Due to the pneumatic bridge circuit and semiconductor pressure sensor, the non-contact

More information

Cylindrical Proximity Sensor

Cylindrical Proximity Sensor Cylindrical Proximity Sensor A New Series of Easy-to-use and Tough Models with a Yellow Indicator New series of TL-X2C1-GE models with improved performance over the previous TL-X-E models. Also, in addition

More information

Mechanical Style Pressure Switch. Specifications

Mechanical Style Pressure Switch. Specifications or details about certified products conforming to international standards, visit us at www.smcworld.com. Mechanical Style Pressure Switch Series IS1000 Long service life: 5 million cycles IS1000-01 IS1000-01-X202

More information