NR2 Thermal Overload Relay. 1. General. 2. Type Designation. 3. Features. Relays. EU Germany Ukrain Russia South Africa USA

Size: px
Start display at page:

Download "NR2 Thermal Overload Relay. 1. General. 2. Type Designation. 3. Features. Relays. EU Germany Ukrain Russia South Africa USA"

Transcription

1 R Relays C US LISTED EU Germany Ukrain Russia South Africa USA NR Thermal Overload Relay. General. Certificates: CE, VDE, Ukrain, PCT, RCC, UL;. Electric ratings: AC 50/0Hz, 90V, 0.A~30A;.3 Tripping class: 0A;. Mounting version: a. Plug-in: Available for NR-.5, 5, 3, 93; b. Independent: Available for NR-50, 00, 30;.5 Standard: IEC/EN Type Designation N R - Current class Design sequence number Thermal overload relay Company code 3. Features 3. 3-phase bimetal 3. Continuously readjustable current settings 3.3 Temperature compensation 3. Tripping indicator 3.5 Test button 3. Stop button 3.7 Manual and automatic reset button 3. Electrically separated N/O plus N/C contact.5.

2 s. Technical Data. Protection properties Item Series No. I/In Operating time Tp Test condition Overload protection > h h min Start from cold status Start from heat status, right after item no. Start from heat status, right after item no. 7. s<tp 0s Start from cold status Phase failure protection 5 Any two phases.0.5 Another phase > h h Start from cold status Start from cold status Start from heat status, right after item no.5 Curves min three phase two phase cold status three phase two phase 0. heat status Multiple of rectified current..

3 Relays. Main Technical Parameters Model NR-.5 Picture Current class(a) 3 Phase failure protection function Automatic & manual reset Temperature compensation Releasing indicator Test & stop pushbutton Mounting mode Plug-in Independent No. of contacts N/O+N/C Auxiliary contacts Rated current (A) (AC-5 0V) Rated current (A) (AC-5 3V).73.5 Rated current (A) (DC-3 0V) 0. Rated operational current(a) Current setting range 0.~0. 0.~ ~ ~ ~ ~..5~ Matched fuse am(a) gg(a) Model NR-93 Picture Current class(a) 93 Phase failure protection function Automatic & manual reset Temperature compensation Releasing indicator Test & stop pushbutton Mounting mode Plug-in Independent Configuration of contacts N/O+N/C Auxiliary contacts Rated current (A) (AC-5 0/30V) Rated current (A) (AC-5 3/00V).73.5 Rated current (A) (DC-3 0/30V) 0. Rated operational current(a) Current setting range 3~3 30~0 37~50 ~5 55~70 3~ ~93 Matched fuse am(a) gg(a)

4 .. NR-5 5 N/O+N/C Current setting range.~.5.5~ 0 ~ 5.5~ 0 7~0 0 9~3 5 ~ 0 7~ NR-3 3 N/O+N/C Current setting range 3~3 0 3 ~3 0 NR-00 NR N/O+N/C Current setting range 30 N/O+N/C Current setting range ~ ~ ~ ~ ~ ~ ~ ~ NR N/O+N/C Current setting range ~ ~0 5 0~

5 Relays 5. Overall and Mounting Dimensions (mm) NR max 5max 7max NR-.5 with Mounting Block L 3L 5L /T /T /T NR-5 3./. 0.7/3. R NR-5 STOP RESET A TEST NO NC H max max T T T3 5max 9max.9.

6 R NR-5 with Mounting Block R.5 L 3 L 5 5 R NR-5 0 TEST STOP RESET A H 7max NO NC T T3 5max 00max NR R NR-3 TEST STOP RESET A H NO NC max 7max T T T3 55max 00max NR-3 with Mounting Block 0 R.5 L 3 L 5 L3 0 5 TEST NR-3 STOP RESET A H 90max NO NC T T T3 55max 00max.50.

7 R R H H Relays NR-93 7max NR-93 TEST STOP RESET A 3max NO NC T T T3 7max NR-93 with Mounting Block max L 3 L 5 NR-93 TEST STOP RESET A 7 05max NO NC T T T3 75max 5 NR max 0 37 max 70max 7max.5.

8 NR-00 M ±0. 3 L 5 L 5 0 0±0. NR-30 3 L 5 L 5 M0 /55* 7 /55* /9* 30±0. 5 /5* 50 5/30* Note: Dimension of product 00A and less / dimension of product above 00A.. Wiring Items Cross section area of conductor mm Main circuit Auxiliary circuit Single core or stranded wire Wiring screw Single core or stranded wire Wiring screw NR-.5 NR-5 NR-3 NR-93 NR-50 NR-00 NR-30 ~ M 0.5~.5 ~ M 0.5~.5 ~0 M 0.5~.5 ~ M0 0.5~.5 5~95 M/M 0.5~.5 5~95 M 0.5~.5 70~ 0 M0 0.5~.5 M3.5 M3.5 M3.5 M3.5 M3.5 M3.5 M3.5.5.

9 Relays 7. Accessories No. Description Application Mounting block for NR-.5 Incorporate with NR-.5 relay to form an independently mounted product Mounting block for NR-5 Incorporate with NR-5 relay to form an independently mounted product 3 Mounting block for NR-3 Incorporate with NR-3 relay to form an independently mounted product Mounting block for NR-93 Incorporate with NR-93 relay to form an independently mounted product. Assembly with contactor Model of overload relay Rated current (A) Recommended fuse type (RT is recommended) am gg Model of contactor 0.~ ~ ~0. 0.~ ~ ~..5~.~.5 NC-09 NC-09~.5~ 0 ~ 5.5~ 0 7~0 0 NR-.5 9~3 5 0.~ ~ ~0. 0.~0.3 NR-5 0.3~ ~..53.

10 3~3 30~0 37~50 ~5 55~70 3~ ~ NC-0 NC-50 NC-5 NC- NC-95 NC-5 NC-50 NR-93 ~5 00~0 5~ NC-5 NC-5 NC-5 NC-330 NC-00 NC-500 NC-30 NR-00 0~50 00~ 50~00 ~500 00~30 ~0 95~0 0~ NR-30 NR-5 3~3 ~ NC-3 NR-3 NC-09 NC- NC- NC-5 NC-3.5~.~.5.5~ ~ 5.5~ 7~0 9~3 ~ 7~ Model of overload relay Rated current (A) Recommended fuse type (RT is recommended) Model of contactor am gg NR-50

11 R Relays C US LISTED USA NRE Electronic Over-load Relay. General. Certificates: UL;. Electrical ratings: AC50/0Hz, 90V;.3 Standards: IEC/EN 097--, UL50. Type Designation N RE - / Mounting version (F: independent; blank: combined) Tripping class (B: 0; blank: 0A) Rated current class Design sequence number Electronic overload relay Company code 3. Features 3. Three-phase electronic type, tripping class0a and Energy saving up to % compared with bimetallic type. 3.3 Phase-failure protection. 3. Current setting continuously adjustable. 3.5 Two indicator lights available for indicating normal, overload time-delay, phase-failure and phase-failure time-delay status respectively. 3. Manual test mechanism. 3.7 Manual reset button. 3. A pair of N/C and N/O contacts. 3.9 Two mounting versions: independent or combined with a contactor.. Technical Data. Main Circuit: Rated insulation voltage: AC 90V; Rated frequency: 50/0Hz. Auxiliary Circuit: Rated insulation voltage: AC 00V; Rated frequency: 50/0Hz; See table below for other ratings. Utilization category AC-5 DC-3 Rated operational voltage Ue (V) Rated operational current Ie (A) Conventional heating current (A).3 Wiring Connection of main circuit is PVC insulation copper conductor or cable. See table below for details: 30.5 Current range (A) Cross section area (mm ) Length (m) Number of piece I <I <I 0 0<I 5 5<I 3 3<I

12 Current range (A) 50<I 5 5<I 5 5<I 5 5<I 50 50<I 75 75<I 5 5<I 50 50<I 75 75<I 0 0<I 00 00<I <I 30 Cross section area (mm ) Length (m) Number of piece Protection Characteristics.. Operation characteristic under three-phase balanced-load status as per the table below. Series No. I/In Operating time Test condition Ambient temperature ( ).05 <h non-tripping Cold status <h tripping Class 0A min Class 0 min Starts from hot status, right after item no. (0±5) 7.0 Class 0A Class 0 s<tp 0s s<tp 0s Cold status Under three-phase operation, if relay current reaches and maintains.05 times of the current setting, the green lamp flashes and red lamp does not light up, which indicates that the relay is not at over-load time-delay status, which equals to non-operation in hours in serial No. of the table above. A current tolerance for serial No. is -3%, and a current tolerance for No. is +3%. Cold status implies the status of the power re-energized of main circuit of relay 5 seconds after its power off... Operation characteristic under phase-failure status as per the table below. Series No. Any two phases I/In The third phase Operating time Tp Test condition Ambient temperature <h non-tripping Starts from cold status Starts from hot (0±5).5 0 <h tripping status, right after item No. Under phase failure operation, if relay current reaches and maintains.0 times of the current setting, the red lamp flashes and green lamp does not light up, which equals to non-operation in hours in serial No. of the table above. When current reaches and exceeds.5 times the current setting, the red lamp flashes and the green lamp lights up, which indicates that the relay is at time-delay release status. A current tolerance for serial No. is -3%, and a current tolerance for No. is +3%..5.

13 Relays.5 Tripping Curve Tripping class 0A Tripping class 0 t(s) t(s) I/Ie 0 I/Ie : Cold status : Hot status : Cold status : Hot status 5. Overall and Mounting Dimensions (mm) 5. For Combined Mounting D.5max.5 NRE-5 Overall and Mounting Dimension 0 CHINT NRE-5 3 Titp 0 5 Test Reset 95 NC 9 97 NO 9 77.max T T T3 max 5max.5 9max NRE-5/F Overall and Mounting Dimension L 3 L CHINT NRE Test Trip Reset 3 NC NO T T3.57.

14 90 95 NRE NC R Test 9 97 Trip NO RESET 9 NRE-0 Overall and Mounting Dimension max 0 CHINT NRE Test Titp Reset 5max 95 NC 9 97 NO 9 T T T3 55max NRE-0/F Overall and Mounting Dimension 55max 5 0max L 3 L 77 CHINT NRE Test Trip RESET 9max 95 NC 9 97 NO 9 T T T3 NRE-00 Overall and Mounting Dimension 0/3.5 0/3.5 0max 7. CHINT NRE Test Trip RESET./7. 95 NC 9 97 NO 9 T T T3 NRE-00 Overall and Mounting Dimension M

15 95 NRE-30 NC R Test 9 97 Trip NO RESET 9 Relays NRE-30 Overall and Mounting Dimension 5 /55* 7 /55* /9 5 /5 50. Applications K K K Manual reset Test Stop L L T T L3 T Overload relay M3~ 7. Accessories 7. Mounting base Description Application NRE-5 mounting bracket Incorporates with NRE-5 to form an independently mounted product NRE-0 mounting bracket Incorporates with NRE-5 to form an independently mounted product.59.

16 7. Assembly with contactors Thermal overload Relay Rated current (A) Current setting range (A) Model of recommended contactor Model of recommended fuse. 0.~. RT3- (NT00-)..~. ~ NC-09 RT3- (NT00-) RT3-0 (NT00-0) ~ RT3- (NT00-) 0 5~0 7~ NC- RT3-0 (NT00-0) RT3-5 (NT00-5) 0 0~0 NC-, NC-5 RT3-0 (NT00-0) NRE ~5 ~3 NC-5 RT3-50 (NT00-50) RT3- (NT00-) ~ RT3-0 (NT00-0) ~ RT3- (NT00-) 0 5~0 NC-3, NC-0 RT3-0 (NT00-0) 0 0~0 RT3-0 (NT00-0) NRE-0 0 0~0 RT3- (NT00-) 5 30~5 NC-50, NC-5 RT3-0 (NT00-0) NRE ~00 NC-, NC-95 RT3-00 (NT-00) NRE ~0 0~0 0~00 NC-5, NC-50 NC-5, NC-5 RT3-50 (NT-50) RT3- (NT-) RT3-00 (NT-00) ~50 5~ 75~00 30~500 NC-5, NC-5 NC-330, NC-00 NC-500, NC-30 RT3-500 (NT3-500) RT3-30 (NT3-30) RT3-0 (NT-0) RT3-000 (NT-000) NRE ~30 RT3-000 (NT-000).0.

Thermal Overload Relays

Thermal Overload Relays Data Sheet Thermal Overload Relays Ex9RD Series Ex9RD93 Ex9RD25 www.noarkusa.com NOARK Ex9RD Series Thermal overload relays are economic electromechanical protection devices for the main circuit. They

More information

Industrial Protection Products Edition

Industrial Protection Products Edition Industrial Protection Products 2016 Edition COMPANY PROFILE Shanghai Liangxin Electrical Co., LTD. one of the leading low-voltage electrical component manufacture in the high-end market, was established

More information

Product range Overload relay ZB up to 150 A. Phase-failure sensitivity IEC/EN 60947, VDE 0660 Part 102

Product range Overload relay ZB up to 150 A. Phase-failure sensitivity IEC/EN 60947, VDE 0660 Part 102 Overloadrelay,10-16A,1N/O+1N/C Partno. ZB12-16 Articleno. 290168 CatalogNo. XTOB016BC1 Deliveryprogramme Product range Overload relay ZB up to 150 A Frame size ZB12 Phase-failure sensitivity IEC/EN 60947,

More information

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting. DATASHEET - ZB12-2,4 Delivery program Overload relay, 1.6-2.4 A, 1N/O+1N/C Part no. ZB12-2,4 Catalog No. 278437 Eaton Catalog No. XTOB2P4BC1 EL-Nummer 0004131832 (Norway) Product range Overload relay ZB

More information

Ktec Contactors and thermal overloads

Ktec Contactors and thermal overloads Contactors and thermal overloads Techna KTEC series contactors provide a complete solution for your ac contactor requirements.the range carries TUV, UL & CSA certification, for use in Europe, North America

More information

Overload Relays. Thermal (Bimetallic) style up to 800A. Overload relay structure

Overload Relays. Thermal (Bimetallic) style up to 800A. Overload relay structure Overload Relays Thermal (Bimetallic) style up to 800A CGT type overload relays are designed for the easy mounting directly to contactors or separately by using additional bases or brackets. Relays frame

More information

Overload Relays. Thermal (Bimetallic) style up to 800A. Overload relay structure

Overload Relays. Thermal (Bimetallic) style up to 800A. Overload relay structure Overload Relays Thermal (Bimetallic) style up to 800A CGT type overload relays are designed for the easy mounting directly to contactors or separately by using additional bases or brackets. Relays frame

More information

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer DATASHEET - ZB65-65 Delivery program Overload relay, 50-65A, 1N/O+1N/C Part no. ZB65-65 Catalog No. 278460 Eaton Catalog No. XTOB065DC1 EL-Nummer 0004131855 (Norway) Product range Overload relay ZB up

More information

Overloadrelay,10-16A,1N/O+1N/C. Articleno

Overloadrelay,10-16A,1N/O+1N/C. Articleno Overloadrelay,10-16A,1N/O+1N/C Partno. ZB32-16 Articleno. 278452 CatalogNo. XTOB016CC1 Deliveryprogramme Product range Overload relay ZB up to 150 A Product range Accessories Accessories Overload relays

More information

Thermal overload relay TF140DU and TF140DU-V1000

Thermal overload relay TF140DU and TF140DU-V1000 Data sheet Thermal overload relay TF140DU and TF140DU-V1000 Thermal overload relays are economic electromechanical protection devices for the main circuit. They are used mainly to protect motors against

More information

Bulletin 193-T1 Bimetallic Overload Relays

Bulletin 193-T1 Bimetallic Overload Relays Bulletin 193T1 Bimetallic Overload Relays Overload protection trip class 10 / 10A Phase loss protection Ambient temperature compensation Auxiliary contacts (1 N.O. and 1 N.C.) Manual/automatic reset mode

More information

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5-

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5- MKING MODERN LIVING POSSIBLE Technical brochure Minicontactors CI 5- www.danfoss.com 2 IC.PD.C10.F3.02-520B4167 Danfoss /S, C-SMC, mr, 07-2010 Contents Page Minicontactor CI 5- Introduction...............................................................................4

More information

Technical Information

Technical Information -100 Controller IEC Performance Data (CSA C22.2, UL 508 No. 14 in connection with a short-circuit protection device Catalog No. -100... 25A 40A 63A 90A Maximum Short-Circuit Current 480V [ka] 65 65 42

More information

Thermal overload relay TF65 and TF96

Thermal overload relay TF65 and TF96 Data sheet Thermal overload relay TF65 and TF96 Thermal overload relays are economic electromechanical protection devices for the main circuit. They are used mainly to protect motors against overload and

More information

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427 Data sheet CI-TI TM Contactors and Motor Starters Circuit Breakers November 2002 DKACT.PD.C00.L2.02 520B1427 Introduction Circuit breakers/manual motor starters cover the power ranges 0.09-12.5 kw This

More information

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking Contactor,4kW/400V,DCoperated Partno. DILEM-10-G(24VDC) Articleno. 010213 Program Product range Contactors Subrange DILEM contactors Application Mini Contactors for Motors and Resistive Loads Description

More information

Quick selection table

Quick selection table Quick selection table Contactors... 100 to 800A Frame size 100A 15A 150A -pole Contactors s AC/DC common coil See page 46 for more details CGC-100 CGC-15 CGC-150 See page 46 for more details Ratings /

More information

Meta Solution. Contactors and Overload relays

Meta Solution. Contactors and Overload relays Meta Solution Contactors and Overload relays Meta Solution New generation of Contactors from LSIS Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol series

More information

Controls. THERMAL OVERLOAD RELAYS RW..D (up to 40A)

Controls. THERMAL OVERLOAD RELAYS RW..D (up to 40A) Controls THERMAL OVERLOAD RELAYS RW..D (up to 0A) 0800 7 9 Thermal Overload Relays RW..D (up to 0A) THERMAL OVERLOAD RELAYS RW..D (up to 0A) Summary Introduction RW7-D Thermal Overload Relay from 0.8 up

More information

Deliveryprogramme. Overloadrelay,24-40A,1N/O+1N/C. Articleno CatalogNo. XTOB040DC1. Auxiliarycontacts. Short-circuitprotection

Deliveryprogramme. Overloadrelay,24-40A,1N/O+1N/C. Articleno CatalogNo. XTOB040DC1. Auxiliarycontacts. Short-circuitprotection Deliveryprogramme Overloadrelay,24-40A,1N/O+1N/C Partno. ZB65-40 Articleno. 278458 CatalogNo. XTOB040DC1 Product range Overload relay ZB up to 150 A Frame size ZB65 Phase-failure sensitivity IEC/EN 60947,

More information

Approved Standards. Ordering Information. Thermal Overload Relay J7TKN. Model Number Legend. Thermal Overload Relay. Accessories

Approved Standards. Ordering Information. Thermal Overload Relay J7TKN. Model Number Legend. Thermal Overload Relay. Accessories Thermal Overload Relay J7TKN ) Thermal Overload Relay Direct and separate mounting Single phasing sensivity according to IEC 60947-4-1 Finger proof (BGV A2) Accessories Set for single mounting Approved

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

Deliveryprogramme. Overloadrelay,6-9A,1N/O+1N/C. Articleno CatalogNo. XTOM009AC1. Settingrange. Auxiliarycontacts. Short-circuitprotection

Deliveryprogramme. Overloadrelay,6-9A,1N/O+1N/C. Articleno CatalogNo. XTOM009AC1. Settingrange. Auxiliarycontacts. Short-circuitprotection Deliveryprogramme Overloadrelay,6-9A,1N/O+1N/C Partno. ZE-9 Articleno. 014708 CatalogNo. XTOM009AC1 Product range ZE overload relays for mini contactor relays Phase-failure sensitivity IEC/EN 60947, VDE

More information

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400 Page -2 Page -4 Page -6 FOR BG SERIES MINI-CONTACTORS Type RF9, phase failure sensitive, manual resetting Type RFA9, phase failure sensitive, automatic resetting Type RFN9, non-phase failure sensitive,

More information

Technical data. Standards: IEC/EN EN 574 EN 418. powder-coated Protection class: IP 65. Cable section: max. 1.5 mm V I the :

Technical data. Standards: IEC/EN EN 574 EN 418. powder-coated Protection class: IP 65. Cable section: max. 1.5 mm V I the : 55 Two-hand control panels SEP System components 460 240 190 30 Standards: IEC/EN 60947-5-5 EN 574 EN 418 cast aluminium, powder-coated Protection class: IP 65 Cable section: max. 1.5 mm 2 U i : 440 V

More information

SIRIUS 3RU2 Thermal Overload Relays

SIRIUS 3RU2 Thermal Overload Relays Overview 1 2 3 4 6 1 2 NSB0_0207a Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors. The overload relay can be connected directly to

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

TAE pole Contactors

TAE pole Contactors TAE9...26 3-pole Contactors d.c. operated with double-winding coil SB8033C3 Utilisation TAE9 to TAE26 contactors are a compliment to the DC control contactor range. The coils have large voltage ranges

More information

Manual Motor Starters. Meta-MEC

Manual Motor Starters. Meta-MEC Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters

More information

D509E. Manual Motor - Starters

D509E. Manual Motor - Starters D509E Manual Motor - Starters Index Page Manual Motors Starters 182 Auxilliary Contact Blocks 182 Trip Alarm Aux. Switch 182 Shunt Release 182 Under-voltage Release 183 Accessories 183 Busbar Connectors

More information

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data B6, B7, BC6, BC7, TBC7 - and 4-pole mini contactors VB6, VB7, VBC6, VBC7 - and 4-pole mini reversing contactors Main pole Utilization characteristics according to IEC Standards IEC/EN 60947-1, IEC/EN 60947-4-1

More information

Essential equipment for all your requirements

Essential equipment for all your requirements NEW CTX CONTACTORS Essential equipment for all your requirements 9 A TO 310 A THREE-POLE INDUSTRIAL CONTACTORS CTX three-pole industrial contactors, a sense of family The new range of CTX contactors provides

More information

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD. DATASHEET - DILMC9-10(24VDC) Technical data General Contactor, 3p+1N/O, 4kW/400V/AC3 Part no. DILMC9-10(24VDC) Catalog No. 277468 Eaton Catalog No. XTCEC009B10TD EL-Nummer 4110305 (Norway) Standards IEC/EN

More information

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF65, EF96 and EF146 Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays are the alternative to the thermal overload relays. An electronic overload relay offers reliable and fast protection

More information

Meta Solution. Contactors and Overload relays

Meta Solution. Contactors and Overload relays Meta Solution Contactors and Overload relays New generation of Contactors from LS Industrial Systems Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol

More information

Electronic overload relays EF205 and EF370

Electronic overload relays EF205 and EF370 Data sheet Electronic overload relays EF205 and EF370 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor

More information

Product range RMQ-Titan (drilling dimensions 22.5 mm) Description Cage Clamp is a registered trademark of Wago Kontakttechnik GmbH/ Minden, Germany

Product range RMQ-Titan (drilling dimensions 22.5 mm) Description Cage Clamp is a registered trademark of Wago Kontakttechnik GmbH/ Minden, Germany Makecontact,CageClamp,Front Partno. M22-CK10 Articleno. 216384 Deliveryprogramme Product range RMQ-Titan (drilling dimensions 22.5 mm) Basic function Accessories Standard/Approval UL/CSA, IEC Construction

More information

Technical Information

Technical Information C5 C5- C5- C5- C5- C5-550 ➊ 700 860 1000 1200 Rated Insulation Voltage U i to IEC 947-1 [V] 1000V 1000V 1000V 690V 690V UL/CS [V] 600V Rated Impulse Voltage U imp C5-550 / 700 / 860 [kv] 3.5 C5-1000 /

More information

Thermal Overload Relays - WEG RW Series, 2 Pole

Thermal Overload Relays - WEG RW Series, 2 Pole International (5) 4-07 The RW Class Thermal Overload Relays, with their extended operational service lives, are designed for use with the CWC miniature and CWM standard contactors. These relays can be

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2. Deliveryprogramme Contactorrelay,3N/O+1N/C,DCcurrent Partno. DILER-31-G-C(110VDC) Articleno. 231831 CatalogNo. XTRMC10A31E0 Product range DILER Mini-contactors Application Contactor relays Description

More information

E44653 SIEMENS AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE AMBERG, GERMANY

E44653 SIEMENS AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE AMBERG, GERMANY Issued to: SIEMENS AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG, GERMANY This is to certify that representative samples of Auxiliary Devices Type No 3RB2 followed by 0 or 1 followed

More information

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2. Deliveryprogram Contactorrelay,2N/O+2N/C,DCcurrent Partno. DILER-22-G(220VDC) Articleno. 010091 CatalogNo. XTRM10A22BD Product range DILER Mini-contactors Application Contactor relays Description with

More information

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up

More information

Industrial Contactors CTX 3 3P 185A - 800A

Industrial Contactors CTX 3 3P 185A - 800A 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Industrial Contactors CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Installation - Connection...

More information

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30 Contactors KNL KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30 Adaptable to various control requirements with ability of mounting from one to four additional auxiliary contacts. Versatile product capable

More information

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3 Introducing the New WEG Series. The was developed according to IEC 60947-3 & UL508. The compact, reliable design of the allows the operator to safely disconnect power and isolate the circuit within the

More information

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current

More information

Application Description

Application Description -14 Type, Intelligent Technologies (IT.) Soft Starters February 2007 Contents Description Page Type, Intelligent Technologies (IT.) Soft Starters Product Description....... -14 Application Description....

More information

CI-TI Contactors and motor starters Types CI 61 - CI 98

CI-TI Contactors and motor starters Types CI 61 - CI 98 Data sheet CI-TI Contactors and motor starters s CI 6 - CI 98 Contactors CI 6, CI 7, CI 86 and CI 98 switch powers of up to 0 kw, 7 kw, 45 kw and 55 kw respectively under 80 V - loads. Accessories include

More information

Overload Relays. SIRIUS 3RU2 Thermal Overload Relays 3RU2 up to 40 A for standard applications. 5/78 Siemens IC Overview

Overload Relays. SIRIUS 3RU2 Thermal Overload Relays 3RU2 up to 40 A for standard applications. 5/78 Siemens IC Overview SIRIUS 3RU2 Thermal Overload Relays 3RU2 up to 40 A Overview 1 2 3 4 6 1 2 NSB0_0207a Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors.

More information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information

CA Z-EN Overload relays, CT-operated overload relays

CA Z-EN   Overload relays, CT-operated overload relays Overload relays, CT-operated overload relays Electronic overload relays, thermistor overload relay for machine protection Setting ranges (A) (note max. current of the contactor) 0.1-12 0.1-16 0.1-38 6-75

More information

Product range RMQ-Titan (drilling dimensions 22.5 mm) Description Cage Clamp is a registered trademark of Wago Kontakttechnik GmbH/ Minden, Germany

Product range RMQ-Titan (drilling dimensions 22.5 mm) Description Cage Clamp is a registered trademark of Wago Kontakttechnik GmbH/ Minden, Germany Break,CageClamp,Front Partno. M22-CK01 Articleno. 216385 CatalogNo. M22-CK01Q Deliveryprogramme Product range RMQ-Titan (drilling dimensions 22.5 mm) Basic function Accessories Standard/Approval UL/CSA,

More information

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN Motor Contactor Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN rail) up to 45 kw Range from 4 to 110 kw (AC 3, 380/415V) Finger proof ( VBG 4) Accessoires

More information

ASL09..S 3-pole Contactors - Spring Terminals

ASL09..S 3-pole Contactors - Spring Terminals 4 kw 5 hp ASL09..S 3-pole Contactors - Spring DC Operated Description - 3-pole contactors with spring terminals, - N.C. or N.O. built-in auxiliary contact, - Low coil consumption, - Polarity on the coil

More information

4 - Miniature controls

4 - Miniature controls Index -....1.22 Selection Contactors for connection to PLCs, B6S & B7S, 3 phase...6 Contactors, Interface, B6 & B7, 3 phase...5 Contactors, features...1 Contactors, mechanically interlocked, B6 & B7, 3

More information

Thermal overload relays Type TA Class 10

Thermal overload relays Type TA Class 10 Thermal overload relays Type TA Class Thermal Overload relays Description Available for starter construction with A Line contactors and separate panel mounting Designed for close couple mounting Separate

More information

Installation Contactors RIC, RAC

Installation Contactors RIC, RAC Installation Contactors RIC, RAC 1 Characteristics Rated operational current: 20 63 A Coil voltages: UC 24, 36, 230 V / AC 400 V Hum-free (UC versions) 2 4 contacts NC or NO Extendable with auxiliary contacts

More information

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101404D0201 24/03/11-30-10-.. / Z-30-10-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

Industry Automation Control Components

Industry Automation Control Components Industry Automation Control Components SIRIUS 3RV2 Motor Starter Protectors SIRIUS 3RV21 Motor Starter Protectors can be easily and flexibly combined with other SIRIUS devices to reduce space requirements

More information

Application Mini Contactors for Motors and Resistive Loads

Application Mini Contactors for Motors and Resistive Loads Delivery program Contactor, 4p, 4kW/400V/AC3 Part no. DILEM4-G(24VDC) Catalog No. 012701 Eaton Catalog No. XTMF9A00TD Product range Contactors Application Mini Contactors for Motors and Resistive Loads

More information

SIRIUS Innovations. Technical information for ring terminals SIRIUS. Answers for industry.

SIRIUS Innovations. Technical information for ring terminals SIRIUS. Answers for industry. SIRIUS Innovations. Technical information for ring terminals SIRIUS Answers for industry. Order data Assembly up to 7.5 kw (S00) fused assembly 2 Motor Starter (Fuses, Contactor, Overload Relay) Contactor

More information

Mini Contactors CI 4-

Mini Contactors CI 4- Data sheet Mini Contactors CI 4- Introduction CI 4 minicontactors cover the power range 1.5 to 5.9 kw and are available for a.c. and d.c. coil voltages. Characteristic of the minicontactors is that they

More information

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2. Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv

More information

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5 3-pole DC Operated Ratings Rated Aux. Contacts Type Coil voltage 1) AC2 Current Built-in Additional 24 24V= DC 5 AC3 see 48 60V= DC 6 380V AC1 page 34 110 110V= DC 7 400V 660V 220 220V= DC 8 415V 690V

More information

Technical data for manual motor starters Type MS325

Technical data for manual motor starters Type MS325 for manual mor starters Type MS325 General data Rated voltage 600 V Rated current 25 A (14 setting ranges, 0.1 25A) Rated frequency 50-60 Hz Electrical and mechanical life endurance 100,000 operations

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660 Characteristics Environment Rated insulation voltage (Ui) Conforming to IEC/EN 60947-1, V 690 IEC/EN 60947-4-1, VDE 0110 gr C, CSA - n 14, UL 508.1 Conforming to standards IEC/EN 60947-1, IEC/EN 60947-4-1,

More information

DEVICE STATE/BYPASSED FAILURE OVERLOAD

DEVICE STATE/BYPASSED FAILURE OVERLOAD Technical specifications Type 5. 7. Control electronics Rated values Terminal Rated control supply voltage A1A2 V AC 115 230 115 230 Tolerance % -15+10-15+10 Rated control supply STANDBY ma 15 15 Rated

More information

CI-TI TM Contactors and Motor Starters Contactors CI 6-50

CI-TI TM Contactors and Motor Starters Contactors CI 6-50 Data sheet CI-TI TM Contactors and Motor Starters Contactors CI 6-50 Description Danfoss contactors CI 6-50 cover the power range 2.2-25 kw. CI 6 is built up as a combined contactor/control relay. CI 9

More information

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated VB6, VB7 -pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated VB7-0-10 2CDC211006F0011 Description VB6, VB7 -pole compact design reversing contactors are space optimized control

More information

Series CA5 Contactors

Series CA5 Contactors Series C5 Contactors The contactor for heavy industrial applications from 500HP to 900HP DISCONTINUED This series is being replaced by the C9 Series of contactors C5 Series contactors provide large horsepower

More information

RSB1A160B7 interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A

RSB1A160B7 interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A Characteristics interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A Stock Code: Stock - Normally stocked in distribution facility Price*: 4.20 USD Complementary Shape of pin Jul 8, 2015 Main Commercial

More information

22AF 40AF AF 150AF 225AF 400AF 800AF

22AF 40AF AF 150AF 225AF 400AF 800AF Contactors MC-Series UL508 E108780 Contactor 3 Pole Standards and Certifications UL508 IEC 60947-2 & IEC 60947-4-2 CSA C22.2 No.14 Features 8 Frame Sizes 1/2HP up to 600HP @ 480V AC Screw Terminals (Lug

More information

Electronic Circuit Breaker ESS20

Electronic Circuit Breaker ESS20 Electronic Circuit Breaker ESS20 Description Electronic circuit breaker type ESS20 is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 24 V switch-mode

More information

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00, Low-Voltage Controls and Distribution > Industrial Controls > Protection Equipment > Circuit Breakers/Motor Starter Protectors > Motor Starter Protectors SIRIUS RV up to 00 A RV0-0DA5 CIRCUIT-BREAKER,

More information

Contactor Types CI 61-98

Contactor Types CI 61-98 MKING MODERN LIVING POSSIBLE Data sheet Contactor s CI 6-98 Contactors CI 6, CI 73, CI 86 and CI 98 switch powers of up to 30 kw, 37 kw, 45 kw and 55 kw respectively under 3 380 V C-3 loads. ccessories

More information

Bimetal Overload Relays 3UA and 3UC

Bimetal Overload Relays 3UA and 3UC 32 Bimetal Overload Relays 3UA and 3UC The 3UA / 3UC thermal overload relays are suitable for customers from all industries, who want guaranteed optimum inverse time delayed protection of their electrical

More information

CI-TI Contactors and Motor Starters Type CI 6-50

CI-TI Contactors and Motor Starters Type CI 6-50 Data sheet CI-TI Contactors and Motor Starters CI 6-50 CI-TI contactors and motor starters provide trouble-free switching and maximum protection for costly motors and other electrical equipment. The components

More information

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.

More information

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E Issued to: SIEMENS AG DF CP R&D VC 2 WERNER-VON-SIEMENS-STRASSE 48 92224 AMBERG, GERMANY This is to certify that representative samples of Auxiliary Devices USL, CNL - Type No. 3RU1146 or 3RU2146 followed

More information

AE 9... AE 40 Contactors NE... Contactor Relays

AE 9... AE 40 Contactors NE... Contactor Relays Technical data AE 9... AE 0 Contactors NE... Contactor Relays AE 9... AE 0 Contactors NE.. Contactor Relays Contents AE 9... AE 0 Contactors Description... 2 Ordering Details... 3 Technical Data... Terminal

More information

UMBW-UL489 and UL1077 Listed

UMBW-UL489 and UL1077 Listed -UL489 and UL77 Listed Introducing the New WEG Series Thermal-Magnetic Miniature Breakers. This new offering includes both UL489 and UL77 approvals to provide a solution for circuit & equipment protection

More information

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866) .4 Miniature Circuit Breakers and Supplementary Protectors SPHM Supplementary Protector SPHM Supplementary Protector Product Description The SPHM Supplementary Protector is a dual rated product for both

More information

06/001. Overload Relays, Motor-Protective Relays Overview. Overload / Motor-Protective Relays. Moeller HPL /2002

06/001. Overload Relays, Motor-Protective Relays Overview. Overload / Motor-Protective Relays. Moeller HPL /2002 Overload Relays, Motor-Protective Relays Overview 06/00 Overload relays, motor-protective relays Page Technical overview 06/00 System overview 05/006 Overload relays, motor-protective relays 06/004 ZE,

More information

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP Soft Starter Three-Phase Scroll Compressor Soft Starter Types RSBD Soft starting of 3-phase scroll compressors up to 95Amp Patented auto-adaptive algorithm for optimum inrush current reduction (No user

More information

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX IEC-Contactor RSC 1 Features Rated operational current 9 63 (C-3) Coil voltages C 24, 230V 3 main contacts and auxiliary contact Extendable with auxiliary contact block Mounting position any 2 Description

More information

Data Sheet Manual Motor Starters Ex9SN Series

Data Sheet Manual Motor Starters Ex9SN Series Data Sheet Manual Motor Starters Ex9SN Series www.noarkusa.com NOARK Ex9SN Series Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors

More information

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory

More information

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 CTX 3 Control relays Cat. N (s) : 4 168 00..04/06/09..14/16/19..24/26/29 CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3.

More information

Ceramic PTC Thermistor:

Ceramic PTC Thermistor: Motor Starter In starter circuit for single-phase a.c. motor, CPTC thermistor is in series connection with starting winding of motor. When motor starts, initial resistance of CPTC thermistor is low and

More information

Electronic Circuit Breaker ESS20-0..

Electronic Circuit Breaker ESS20-0.. Electronic Circuit Breaker ES-0.. Description Electronic circuit breaker type ES-0.. is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 4 V switch-mode

More information

Motor protective circuit breakers

Motor protective circuit breakers Motor protective circuit breakers Motor protective circuit breakers MSP Description The MSP0, MSP1 motor starter protectors are compact motor starter protectors for currents up to 52 A which operate according

More information

3RT14 Contactors with 3 Main Contacts

3RT14 Contactors with 3 Main Contacts 3RT14 Contactors with 3 Main Contacts for Switching Resistive Loads Contactor Size 3RT14 46 Mechanical endurance Oper. 10 million Electrical endurance Oper. 0.5 million C-1 utilization category at I e

More information

Safety switches for hinged doors

Safety switches for hinged doors 4C Safety switches for hinged doors Selection diagram CONTACT BLOCKS 18 7 9 20 overlapped 1NO+ FD FL FC 21 22 33 34 2NO+1NC 3NC CONDUIT ENTRIES Threaded conduit entries (standard) With cable gland assembled

More information

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters

More information

NB1 Miniature Circuit Breaker

NB1 Miniature Circuit Breaker P-00 Modular DIN Rail Products MCB NB Miniature Circuit Breaker Color coded contact position indicator provides visual indication of the device status and insulation function Magnetic trip elements provide

More information

Cylindrical fuse-link

Cylindrical fuse-link Cylindrical fuse-link Technical data Rated voltage Rated current Rated frequency Rated breaking capacity Characteristics ody material 00 V AC, 00 V AC, 90 V AC CH 8 - A/00 V CH 0,- A/00 V, 0-3 A/00 V CH

More information

B Mini Contactor V Hz

B Mini Contactor V Hz ABB B7-30-10-80 Mini Contactor 220-240V 40-450Hz General Information Extended Product Type Product ID B7-30-10-80 GJL1311001R8100 EAN 4013614150197 Catalog Description Long Description B7-30-10-80 Mini

More information