Instructions For PG-1200RC Magnetic Locking Devices

Size: px
Start display at page:

Download "Instructions For PG-1200RC Magnetic Locking Devices"

Transcription

1 Instructions For PG-1200RC Magnetic Locking Devices (Remote control distance up to 10 meters) Ver Please Read Carefully Before Installing Magnetic Lock A. Carefully for handling to prevent damage for the plate surface of magnet or armature, it may reduce locking efficiency. B. The magnet must be mounted rigidly to the door frame. Then fix the armature to the door by using the screws. If the door can not be fixed closely, you may move the armature, so that it can match with the surface of the magnet completely. C. Firmly tighten all screws. Typical Installation STEP 1 A. Fold template along dotted line. B. Place template against door and head frame. C. Drill holes as indicated on template. STEP 2 A. Mount the armature plate to door by using 1 rubber washer sandwiched between 2 steel washers. ( The rubber washer and 2 steel washer are installed on the through Hexagon screw between armature plate and door). STEP 3 A. Install the mounting plate with 2 flat head screws (the 2 M5 5 flat head screws are installed on the slotted holes for adjustment). B. Adjust the mounting plate so that it forms right angle with the armature plate. C. Using the mounting plate as a temple, drill the wire hole. D. Drill the remaining mounting screws. 1

2 STEP 4 A. Install magnet to mounting plate with 2 M4 screws supplied. STEP 5 A. Test all functions of this model (see wiring instruction). Armature Plate Mounts To The Door: *Important:Do not fix the armature plate too tightly, and make the rubber washer more flexible in order to let the armature plate automatically adjust its proper position with magnet. 12VDC Input: A. Required power 1.0Amp ( Minimum ). B. Connect the ground (-) lead from a 12VDC power source to Black line. C. Connect the positive (+) lead from a 12VDC power source to Red line. D. Check jumper for 12VDC operation. 24VDC Input: A. Required power 0.5Amp ( Minimum ). B. Connect the ground (-) lead from a 24VDC power source Black line. C. Connect the positive (+) lead from a 24VDC power source to Red line. D. Check jumper for 24VDC operation. Contacts: A. Relay dry contacts are rated as 24VDC/1.0A for safe operation. Do not exceed this rating. B. If you require a normally opened dry contacts, please connect the wires of Yellow and Orange. If you require a normally closed dry contacts, please connect the wires of Yellow and Green. 2

3 Printed Circuit Board Schematic The procedure of adding /deleting transmitter (up to 40 transmitter s ID.) 1. Adding transmitter 1.1 Adjust the JUMPER(JP) to the desired channel to receive. The communication indicator will flash. After 35 seconds; It means the programming is complete. 1.2 Pressing the learning mode button(msw1) on the PCB, the communication indicator will flash and starting learning mode. (The learning mode will be automatically closed after 35 seconds of inactivity) 1.3 According to the channel set by JUMPER (JP), press the corresponding button on the PTX-204DF to match. 1.4 After all the transmitters are matched, please power off the lock and put on the armature plate. After 3 seconds, re-power the lock and wait the lock is activated (the armature is secured), press the matched button on PTX-204DF. If the armature plate is released, that means the setting is completed. 2. Deleting transmitter If any transmitter is lost, all transmitters should be deleted and reprogrammed. Pressing the learning mode button for 10 seconds without re-power, the communication indicator will flash to complete the deleting. Important A. The product should be only supplied with UL listed power supply. B. If the power switch is not wired directly between DC voltage source and magnet, it will take time to de-energize the residual magnetism(see below). C. Please make sure your jumper pin is in the proper position. 3

4 Wiring connection with reader Dimensions: mm[inch] Q & A FOR PML series: A. Once powered, the pilot light isn t responded to ON : (1) If the voltage selection of the printed circuit board was set DC 24V, please check your power supply with at least DC 24V, 500mA. (2) Maybe the DC (+), (-) polarity is reversed. (3) Maybe the jumper was put in wrong position, please reverse it and try again. 4

5 B. Once powered, if pilot light turns on, but lacking magnetic force and magnet could not attract the armature, the reasons may be as follows: (1)Please check if the power voltage is larger than DC24V (power supply must be DC24V, 500mA+/-5% Minimum) (2)Maybe the magnet & armature do not match completely tight, please adjust the position between the magnet and armature. (3)The transformer s quality causes interference please check if the poor quality of the transformer induced the interference. If yes, please replace another one. C. Once powered, the pilot light turns on, but the magnetic force is not enough: (1) The magnet and armature cannot attract tightly, please check if there is some dust between them. (2) The magnet and armature of the lock doesn t align completely, please adjust them. (3) Maybe due to under voltage or wrongly jumped, please double check. D. Once powered, if the lock cannot attract immediately, then the reason could be as follows: (1) The time delay is too long, please shorten it by adjusting the knob counterclockwisely. (2) Maybe the time period which is controlled by the external controller (such as reader, etc..) is too long, please adjust the time period of external controller. Specifications subject to change without notice for further modification. 5 PG-1200RC

6 TEMPLATE TEMPLATE FOR FAS-PG-1200RC PLACE AGAINST HEADER (1/8") DRILL 3.2mm HOLE (2 PLACES) Drill 10mm hole for wring connection FOLD THIS DOTTED LINE L.H.R. DOOR INSTALLATION PLACE AGAINST DOOR (1/4") 6mm DIA.ARMATURE GUIDE PINS HOLE mm DEEP (1/2") R.H.R. DOOR INSTALLATION (11/16") DRILL 16mm HOLE PG-1200RC

MODEL 600LB 600 POUND SINGLE MAGNETIC LOCK WITH LED, BOND SENSOR & DOOR STATUS SENSOR SPECIFICATIONS

MODEL 600LB 600 POUND SINGLE MAGNETIC LOCK WITH LED, BOND SENSOR & DOOR STATUS SENSOR SPECIFICATIONS MODEL 600LB 600 POUND SINGLE MAGNETIC LOCK WITH LED, BOND SENSOR & STATUS SENSOR SPECIFICATIONS U.L. LISTED, LISTING NUMBER R16759 600 POUND MINIMUM HOLDING FORCE MAGNET SIZE 9-7/8 L x 1-11/16 H x1 W SIZE

More information

SL-150 Magnetic Lock for Sliding Door Installation Manual

SL-150 Magnetic Lock for Sliding Door Installation Manual SL-150 Magnetic Lock for Sliding Door Installation Manual SOCA TECHNOLOGY CO., LTD. COPYRIGHT 2003 NOV V2.0 1. Specifications: All-in-one design for easy installation. The lock itself would not have any

More information

MODEL 1200S MAGNETIC LOCK

MODEL 1200S MAGNETIC LOCK MODEL 1200S MAGNETIC LOCK SPECIFICATIONS U.L. LISTED, LISTING NUMBER R16759 1200 POUND MINIMUM HOLDING FORCE MAGNET SIZE 10-1/2 L x 2-7/8 H x1-1/2 W 12 OR 24 VOLT DC OPERATION, JUMPER SELECTABLE CURRENT

More information

* * M400 Series. Features. Models. Trims. UL Requirements. Single Electromagnetic Locks: M420, M450, M490. Installation Instructions

* * M400 Series. Features. Models. Trims. UL Requirements. Single Electromagnetic Locks: M420, M450, M490. Installation Instructions *44487296* M400 Series 44487296 Single Electromagnetic Locks: M420, M450, M490 Installation Instructions M420/M450 Armature plate assembly M490 Armature plate assembly Features Automatic Voltage Selection

More information

Shaved-B. Installation Manual & Operation Instructions

Shaved-B. Installation Manual & Operation Instructions Shaved-B Installation Manual & Operation Instructions Each Kit Contains The Following Components (1) Receiver (2) Remotes (2) Wire Harnesses Installation Instructions for SPAL Shaved Door Handle Kit Shaved-40

More information

Installation Instructions for Slide Mount Magnetic Locks

Installation Instructions for Slide Mount Magnetic Locks ROFU For Outswing Doors Installation Instructions for Slide Mount Magnetic Locks 8606, 8608 and 8612 Series *See page 2 for model specifications R Find the paper installation template included with the

More information

Security and Keyless Entry Installation Guide ca 1051

Security and Keyless Entry Installation Guide ca 1051 PROFESSIONAL SERIES Security and Keyless Entry Installation Guide ca 1051 ca1051 rev B. 2011 Audiovox Electronics Corporation. All rights reserved. 1 Table of Contents Before You Begin... 3 Wire Connection

More information

MODEL 1200S MAGNETIC LOCK

MODEL 1200S MAGNETIC LOCK MODEL 1200S MAGNETIC LOCK SPECIFICATIONS U.L. LISTED, LISTING NUMBER R16759 1200 POUND MINIMUM HOLDING FORCE MAGNET SIZE 10-1/2 L x 2-7/8 H x1-1/2 W 12 OR 24 VOLT DC OPERATION, JUMPER SELECTABLE CURRENT

More information

SHAVED-DX. Installation Manual & Operation Instructions. Trouble Shooting Reverse Polarity Wiring Problems

SHAVED-DX. Installation Manual & Operation Instructions. Trouble Shooting Reverse Polarity Wiring Problems Trouble Shooting Reverse Polarity Wiring Problems Switch doesn't work properly but the shaved kit transmitters do work Step 1 Did you purchase a switch kit designed for three switches and only use two

More information

MODEL 600S 600 POUND SINGLE MAGNETIC LOCK SPECIFICATIONS

MODEL 600S 600 POUND SINGLE MAGNETIC LOCK SPECIFICATIONS MODEL 600S 600 POUND SINGLE MAGNETIC LOCK SPECIFICATIONS U.L. LISTED, LISTING NUMBER R16759 600 POUND MINIMUM HOLDING FORCE MAGNET SIZE 9-7/8 L x 1-11/16 H x1 W SIZE 5-1/2 L x 1-1/4 W x 7/16 D 12 OR 24

More information

STANDARD / DOUBLE STANDARD MAGNETIC LOCK

STANDARD / DOUBLE STANDARD MAGNETIC LOCK STANDARD / DOUBLE STANDARD MAGNETIC LOCK INSTALLATION MANUAL INDOOR ELECTROMAGNETIC LOCK SERIES Spec/Model GEM-300 Single GEM-600 GEM-800 GEM-1200 Double GEM-D600 GEM-D800 GEM-D1200 Holding Force 300lbs

More information

MODEL 1200LB 1200 POUND MAGNETIC LOCK WITH LED, BOND SENSOR & DOOR STATUS SENSOR

MODEL 1200LB 1200 POUND MAGNETIC LOCK WITH LED, BOND SENSOR & DOOR STATUS SENSOR MODEL 1200LB 1200 POUND IC LOCK WITH LED, BOND SENSOR & STATUS SENSOR U.L. LISTED, LISTING NUMBER R16756 1200 POUND MINIMUM HOLDING FORCE SIZE: 10-1/2 L x 2-7/8 H x 1-1/2 W SIZE: 7-3/8 L x 2-3/8 W x 9/16

More information

MCC Automatic Start-Stop Microcomputer Charger Control

MCC Automatic Start-Stop Microcomputer Charger Control MCC Automatic Start-Stop Microcomputer Charger Control Installation & Operation Instructions Warning: Read ALL the instructions before starting. If anything is not clear, call your dealer or contact Arrgh!!

More information

INSTALLATION INSTRUCTIONS E300 SERIES MAGNETIC CABINET/DISPLAY CASE LOCK

INSTALLATION INSTRUCTIONS E300 SERIES MAGNETIC CABINET/DISPLAY CASE LOCK 801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS E300 SERIES MAGNETIC CABINET/DISPLAY CASE LOCK The E300 Series magnetic

More information

With LED, Bond Sensor E-941SA-600PQ 600-lb. (272kg) E-941SA-1K2PQ 1200-lb. (545kg) Weatherproof E-941SA lb.

With LED, Bond Sensor E-941SA-600PQ 600-lb. (272kg) E-941SA-1K2PQ 1200-lb. (545kg) Weatherproof E-941SA lb. Electromagnetic Lock E-941SA-600 600-lb. (272kg) E-941SA-1200 1200-lb. (545kg) With LED, Bond Sensor E-941SA-600PQ 600-lb. (272kg) E-941SA-1K2PQ 1200-lb. (545kg) Weatherproof E-941SA-300 300-lb. (136kg)*

More information

INSTALLATION/OPERATING INSTRUCTIONS TSC

INSTALLATION/OPERATING INSTRUCTIONS TSC INSTALLATION/OPERATING INSTRUCTIONS TSC Two-Stage Set Point Control with External Activation Two-Stage Heating (Rotation Included) Two-Stage Cooling (Rotation Included) Change-Over Control (Heat/Cool)

More information

Model APS-101N Installation Manual

Model APS-101N Installation Manual Programmable Features Model APS-101N Installation Manual Select By Operating Transmitter Press Lock Button Press Unlock Button Siren Indications 1 Chirp 2 Chirps Factory Default 1) Arming Method Passive

More information

ASSA ABLOY Series Multi-Point Hold Open Installation and Instruction Manual

ASSA ABLOY Series Multi-Point Hold Open Installation and Instruction Manual Pull Side Applications with Slide Track (7210, 7250) (see page 7 for template) 7200 Series Multi-Point Hold Open Installation and Instruction Manual 3 1 Push Side Applications with Double Lever Arms (7220,

More information

MODEL 600LB 600 POUND SINGLE MAGNETIC LOCK WITH LED, BOND SENSOR & DOOR STATUS SENSOR SPECIFICATIONS

MODEL 600LB 600 POUND SINGLE MAGNETIC LOCK WITH LED, BOND SENSOR & DOOR STATUS SENSOR SPECIFICATIONS MODEL 600LB 600 POUND SINGLE MAGNETIC LOCK WITH LED, BOND SENSOR & STATUS SENSOR SPECIFICATIONS U.L. LISTED, LISTING NUMBER R16759 600 POUND MINIMUM HOLDING FORCE MAGNET SIZE 9-7/8 L x 1-11/16 H x1 W SIZE

More information

IMPORTANT! Remote Control Instructions

IMPORTANT! Remote Control Instructions Remote Control Instructions FOR New Tarp Remote Control Installation Use these in place of the rocker switch and solenoid section of instructions in your roll tarp owner s manual. FOR Existing Electric

More information

Vehicle Alarm System With Channel 2 Auxiliary Output Installation Instructions

Vehicle Alarm System With Channel 2 Auxiliary Output Installation Instructions Model PRO 9842 Installation Manual Vehicle Alarm System With Channel 2 Auxiliary Output Installation Instructions This Unit Is Intended For Installation In Vehicles With 12 Volt Negative Ground Electrical

More information

INSTALLATION INSTRUCTIONS 1576DE DELAYED EGRESS EMLOCK

INSTALLATION INSTRUCTIONS 1576DE DELAYED EGRESS EMLOCK 801 Avenida Acaso, Camarillo, Ca. 930 (805) 494-0622 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 1576DE DELAYED EGRESS EMLOCK PUSH UNTIL ALARM SOUNDS. DOOR CAN BE OPENED

More information

INSTALLER MANUAL USER MANUAL. Contents

INSTALLER MANUAL USER MANUAL. Contents Installation & user manual two way Contents INSTALLER MANUAL Important information General 1. Technical data 2. Description Installation: 1. Positioning the unit 2. Connection. 3. Parts description. 4.

More information

Remote Keyless Entry Installation Guide ca 2051

Remote Keyless Entry Installation Guide ca 2051 PROFESSIONAL SERIES Remote Keyless Entry Installation Guide ca 2051 ca2051 rev B. 2011 Audiovox Electronics Corporation. All rights reserved. 1 Table of Contents Before You Begin... 3 Wire Connection Guide...

More information

YG101 SWING GATE OPENER OWNER S MANUAL

YG101 SWING GATE OPENER OWNER S MANUAL YG101 SWING GATE OPENER OWNER S MANUAL IMPORTANT SAFTEY INFORMATION Installing the YG101 Gate Opener requires wiring of standard 110V electrical lines. This should only be performed by a trained technician.

More information

Lippert Components, Inc. Informational Publication ENTRY DOOR LATCH INFORMATION - SOUTHCO

Lippert Components, Inc. Informational Publication ENTRY DOOR LATCH INFORMATION - SOUTHCO Lippert Components, Inc. Informational Publication LIP Sheet - 0182 revd ENTRY DOOR LATCH INFORMATION - SOUTHCO SOUTHCO, Inc. door latches are used in Lippert s Keyless Entry Door systems. All Southco

More information

CD3000S-1PH Thyristor Unit Analog Input version

CD3000S-1PH Thyristor Unit Analog Input version USER S MANUAL Rev. 01/2007 CD3000S-1PH Thyristor Unit Analog Input version from 15A to 110A CD Automation S.r.l. Via Picasso 34/36-20025 Legnano (MI) ITALY Tel +39 0331 577479 Fax +39 0331 579479 E-Mail:

More information

Vehicle Security System

Vehicle Security System Installation Instructions Vehicle Security System PROFESSIONAL INSTALLATION STRONGLY RECOMMENDED Installation Precautions: Roll down window to avoid locking keys in vehicle during installation Avoid mounting

More information

Model PRO 9644a Installation Manual

Model PRO 9644a Installation Manual Model PRO 9644a Installation Manual SELECTABLE FEATURES Note: The method of manual override can either be selected to operate from the valet switch operate as custom code. Be certain to place a check mark

More information

HANDLING MECHANICAL INSTALLATION

HANDLING MECHANICAL INSTALLATION 2 INSTALLATION DESCRIPTION The and 2 Delay Egress Systems are 1500 pound holding force (holding force not evaluated by UL) per leaf electromagnetic locks, electronically controlled to provide a 15 or 30

More information

Electric Actuator Instructions

Electric Actuator Instructions BAC IOM Electric Actuator Instructions E024, E025, E026, E029 & E030 TABLE OF CONTENTS Electric Actuator Specifications...2 Overview...3 Actuator Wiring Diagrams...4 VMS-35 Specifications and Wiring Diagram...5

More information

Installing the gate post bracket with the cardboard arm template

Installing the gate post bracket with the cardboard arm template ......... Installing the gate post bracket with the cardboard arm template... Installing gate posts brackets and arms for Push-to-Open or Pull-to-Open gates... Connection of Power Source 240Vac or Solar...

More information

ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI

ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI II 1400-6 ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI ACSI 1426-04-AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1092, REV. C INSTALLATION For C-UL Listed applications,

More information

Installing the gate post bracket with the cardboard arm template

Installing the gate post bracket with the cardboard arm template ......... Installing the gate post bracket with the cardboard arm template... Installing gate posts brackets and arms for Push-to-Open or Pull-to-Open gates... Connection of Power Source 240Vac or Solar...

More information

Carbon Monoxide Transmitter

Carbon Monoxide Transmitter Introduction The CO Transmitter uses an electrochemical sensor to monitor the CO level and outputs a 4-20 ma signal. The standard product features a 2- wire loop-powered output. Optionally, the device

More information

PLEASE READ ALL INSTRUCTIONS PRIOR TO INSTALLING THE ELECTROMAGNETIC LOCK.

PLEASE READ ALL INSTRUCTIONS PRIOR TO INSTALLING THE ELECTROMAGNETIC LOCK. 575 Birch Street, Forestville, CT 06010 Phone (866) 322-1237 Fax (866) 322-1233 WWW. LOCKNETICS.COM 390/390-2 DEL INSTALLATION AND PROGRAMMING 390DEL DELAYED EGRESS General Description... 2 Technical Specifications...

More information

Gas Spreader PLUS Remote Kit With Built in Clutch Relay and On/Off Switch

Gas Spreader PLUS Remote Kit With Built in Clutch Relay and On/Off Switch Gas Spreader PLUS Remote Kit With Built in Clutch Relay and On/Off Switch NOTE: Read all directions first before continuing. This wireless controller kit has been programmed and tested before shipping.

More information

Compact Low Pressure Sensor

Compact Low Pressure Sensor Overview The Low Pressure Sensor is a true differential pressure transmitter that provides ±1 inches WC (±250 Pacals) in 10 field selectable ranges (see specifications). The enclosure is designed for DIN

More information

M670/M680BD MAGNALOCK SERIES Installation Instructions

M670/M680BD MAGNALOCK SERIES Installation Instructions Securitron www.securitron.com Tel 800.624.5625 techsupport@securitron.com M670/M680BD MAGNALOCK SERIES Installation Instructions Page 1 Rev. D, 12/14 Table of Contents Package Contents... 3 Mounting Hardware...

More information

INQUIRY: HYROBOTICS CORP SAM LEE ( ) 5988 MID RIVER MALL DR. ST.CHARLES MO TEL : FAX :

INQUIRY: HYROBOTICS CORP SAM LEE (   ) 5988 MID RIVER MALL DR. ST.CHARLES MO TEL : FAX : INQUIRY: HYROBOTICS CORP SAM LEE ( Email : hanrobotic@msn.com ) 5988 MID RIVER MALL DR. ST.CHARLES MO 63304 TEL : 1-636-578-6059 FAX : 1-866-232-5594 1. Picker Body Installation 1-1. Picker Assembly. (Step

More information

Covers All 430, 440, 441 and CJ Series Advanced Security Systems.

Covers All 430, 440, 441 and CJ Series Advanced Security Systems. INSTALL GUIDE Covers All 430, 440, 441 and CJ Series Advanced Security Systems www.ultrastarters.com Technical Support: 866-698-5872 ext 0 support@ultrastarters.com FCC/ID Notice This device complies with

More information

Contacts NEMA A600, 10A thermal. Contacts NEMA Q600, 5A thermal. Wire size

Contacts NEMA A600, 10A thermal. Contacts NEMA Q600, 5A thermal. Wire size Technical data UL Pilot Devices General UL technical data Contact blocks Rated insulation voltage, UL 600V Rated thermal current 10A / 600VAC 2.5A / 600VDC Minimum rating 24VDC, 5mA Mechanical life (millions

More information

CD3000S-1PH Thyristor Unit Heater Break version

CD3000S-1PH Thyristor Unit Heater Break version USER S MANUAL Rev. 01/2007 CD3000S-1PH Thyristor Unit Heater Break version from 15A to 110A CD Automation S.r.l. Via Picasso 34/36-20025 Legnano (MI) ITALY Tel +39 0331 577479 Fax +39 0331 579479 E-Mail:

More information

MASTER SALT SAND SPREADER WIRELESS CONTROL MANUAL

MASTER SALT SAND SPREADER WIRELESS CONTROL MANUAL MASTER SALT SAND SPREADER WIRELESS CONTROL MANUAL This manual covers 1. Gas spreader wireless controllers (Standard) 2. Gas spreader wireless controllers (Plus) 3. 600DC single motor spreader wireless

More information

V2M1200/1290 Series Maglock Installation Instructions

V2M1200/1290 Series Maglock Installation Instructions Securitron Phoenix, AZ 85044 Tel: 1-800-624-5625 Mon-Fri: 6:00am - 4:00pm PDT Fax: 1-800-232-7329 www.securitron.com V2M1200/1290 Series Maglock Installation Instructions 1 Table of Contents Product Information...

More information

INSTALLATION MANUAL. Model: PLUS For Technical Assistance, please call (800) , or visit

INSTALLATION MANUAL. Model: PLUS For Technical Assistance, please call (800) , or visit R Vehicle Security INSTALLATION MANUAL Model: PLUS-4700 This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference;

More information

Security Door Controls

Security Door Controls Security Door Controls 801 Avenida Acaso, Camarillo, ca. 930 (805) 494-0622 Fax: (805) 494-8861 www.sdcsecurity.com E-mail: service@sdcsecurity.com 1575-1576 EMLOCK R INSTALLATION INSTRUCTIONS During installation,

More information

DLKEK3HN INSTALLATION INSTRUCTIONS

DLKEK3HN INSTALLATION INSTRUCTIONS DLKEK3HN INDEX: INSTALLATION INSTRUCTIONS WIRING INSTRUCTIONS... PG 2-5 LED STATUS INDICATOR... PG 6 VALET/OVERRIDE BUTTON... PG 6 SHOCK SENSOR... PG 7 PROGRAMMABLE JUMPER-PINS... PG 7 PROGRAMMING REMOTE

More information

ADA EZ Rev. H, 8/23/11

ADA EZ Rev. H, 8/23/11 Installation and Operating Instructions ADA EZ Installation and Operating Instructions EZ040 Note Changes or modifications not expressly approved by the party responsible for compliance could void the

More information

CM 5000D IN A HURRY?

CM 5000D IN A HURRY? CM 5000D Conventional and Tunnel Instructions IN A HURRY? Flip to Pages 6-13 for Wiring Diagrams 4-11. Investigate The REEL-FREE Winch Handle The REEL-FREE Winch Handle adds features to your curtain winching

More information

Signet Pressure Transmitter

Signet Pressure Transmitter Signet 80 Pressure 80.090 80.090 Rev. J 0/ English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury. Contents. Installation.

More information

2 WAY REMOTE STARTER & ALARM SYSTEM INSTALLATION GUIDE FCC ID NOTICE

2 WAY REMOTE STARTER & ALARM SYSTEM INSTALLATION GUIDE FCC ID NOTICE REV. ARS. WAY REMOTE STARTER & ALARM SYSTEM INSTALLATION GUIDE FCC ID NOTICE This device complies with Part 5 of the FCC rules. Operation is subject to the following conditions:. This device may not cause

More information

Troubleshooting Bosch Proportional Valves

Troubleshooting Bosch Proportional Valves Troubleshooting Bosch Proportional Valves An Informative Webinar Developed by GPM Hydraulic Consulting, Inc. Instructed By Copyright, 2009 GPM Hydraulic Consulting, Inc. TABLE OF CONTENTS Bosch Valves

More information

ELECTRIC ACTUATOR HVAC/BAC ELECTRIC IOM. E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS

ELECTRIC ACTUATOR HVAC/BAC ELECTRIC IOM. E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS HVAC/BAC ELECTRIC IOM ELECTRIC ACTUATOR E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS Electric Actuator Specifications... 2 Overview... 3 Actuator

More information

Sensors W2 and E2 are optional. Installation guide, 'Pickle Fork' Back-and-Forth Model Train Controller

Sensors W2 and E2 are optional. Installation guide, 'Pickle Fork' Back-and-Forth Model Train Controller Installation guide, 'Pickle Fork' Back-and-Forth Model Train Controller Azatrax model PFRR-NTO This controller can automate a single track 'back-and-forth' model train layout -- or, one train can travel

More information

Vehicle Security System

Vehicle Security System Installation Instructions Vehicle Security System PROFESSIONAL INSTALLATION STRONGLY RECOMMENDED Installation Precautions: Roll down window to avoid locking keys in vehicle during installation Avoid mounting

More information

Manual - Inside Front Cover (Blank)

Manual - Inside Front Cover (Blank) FRONT COVER Manual - Inside Front Cover (Blank) Table of Contents Important Information... 2 Recommended Installation Tools... 2 Recommended Procecures... 2 Wiring Diagram... 3 14 Pin Connector...4 Installation

More information

Signet Pressure Transmitter

Signet Pressure Transmitter Signet 8450 Pressure English 8450.090 8450.090 Rev. G /06 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury. Contents

More information

USERS GUIDE LO-21U LOCKOUT RELAY

USERS GUIDE LO-21U LOCKOUT RELAY USERS GUIDE LO-21U LOCKOUT RELAY PRODUCT DESCRIPTION The LO-21U (PN: 10LO21U) is a micro-processed lock out module designed to operate on swing door applications with BEA s Bodyguard or DK-12 overhead

More information

Contacts NEMA A600, 10A thermal. Contacts NEMA Q600, 5A thermal. Low energy contacts gold plated. Minimum PUSHBUTTON

Contacts NEMA A600, 10A thermal. Contacts NEMA Q600, 5A thermal. Low energy contacts gold plated. Minimum PUSHBUTTON Pilot Devices Technical data UL General UL technical data Contact blocks Rated insulation voltage, UL 600V Rated thermal current 10A / 600VAC 2.5A / 600VDC Minimum rating 24VDC, 5mA Mechanical life (millions

More information

ELECTRIC ACTUATOR 94OE IOM. E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS

ELECTRIC ACTUATOR 94OE IOM. E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS ELECTRIC ACTUATOR E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS 94OE IOM Electric Actuator Specifications...2 Overview...3 Actuator Wiring Diagrams...4

More information

Signet Temperature Transmitter

Signet Temperature Transmitter Signet 80 Temperature English 80.090 80.090 Rev. G /0 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury. Contents.

More information

2 Way Security and Keyless Entry Installation Guide ca 1553

2 Way Security and Keyless Entry Installation Guide ca 1553 PROFESSIONAL SERIES 2 Way Security and Keyless Entry Installation Guide ca 1553 2012 Audiovox Electronics Corporation. All rights reserved. 1 Table of Contents Before You Begin... 3 Wire Connection Guide...

More information

FM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017

FM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017 FM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017 Maxi-Tronic, Inc. 417 Wards Corner Road Loveland, OH 45140 513.398.2500 800.659.8250 FAX: 513.398.2536 info@maxitronic.com

More information

INSTALLATION/OPERATING INSTRUCTIONS MCP

INSTALLATION/OPERATING INSTRUCTIONS MCP INSTALLATION/OPERATING INSTRUCTIONS MCP Modulating Digital Set Point Control with Boiler Output and External Activation Temperature Range -30 to 250 F (-35 to 120 C) Pressure Ranges 0-30, 0-100, 0-200PSI

More information

5700 Series Power Operator Hinge (Pull) Side Mount Installation and Instruction ASSA Manual ABLOY

5700 Series Power Operator Hinge (Pull) Side Mount Installation and Instruction ASSA Manual ABLOY 5700 Series Power Operator Hinge (Pull) Side Mount Installation and Instruction ASSA Manual ABLOY 80-957-000-00 (06-5) Patents 5,88,97; 7,6,096; 7,8, 6 5 0 8 7 9 Item No. Description Back plate Door Closer

More information

CA-110 Installation Instructions

CA-110 Installation Instructions CA-110 Installation Instructions PROFESSIONAL INSTALLATION STRONGLY RECOMMENDED Installation Precautions: Roll down window to avoid locking keys in vehicle during installation Avoid mounting components

More information

DTS SECURITY P.O.BOX 3399 EDENVALE 1610 Base plate-mounting instructions TELEPHONE

DTS SECURITY P.O.BOX 3399 EDENVALE 1610 Base plate-mounting instructions TELEPHONE DTS ECO 500 SLIDING GATE MOTOR INSTALLATION MANUAL DTS SECURITY P.O.BOX 3399 EDENVALE 1610 Base plate-mounting instructions TELEPHONE 086 1000 387 Spartan +2711 392 5540 (H/O) Pretoria +2712 361 5528 Alberton

More information

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load G6C - - VDC

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load G6C - - VDC PCB Relay SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load Compact: 20 15 10 mm (L W H). Low power consumption: 200 mw. Flux protection or fully sealed construction available. Unique

More information

Fitting Instructions. Armlock 1354 Mini Electro-Shearmagnet (Surface) Contents

Fitting Instructions. Armlock 1354 Mini Electro-Shearmagnet (Surface) Contents Fitting Instructions Armlock 1354 Mini Electro-Shearmagnet (Surface) Contents Before You Start...page 1 Installation instructions for wood, aluminium and glass...page 2 Wiring Diagram...page 3 Wiring and

More information

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY 0 Series Power Operator Installation and Instruction ASSA Manual ABLOY Item No. Description Motor (00M) Cover (00COV) Control Inverter (00IN) Power Supply VDC (00PS) / Replacement Motor Key (00KEY) Rod

More information

6500DC Dual Motor Wireless Controller Kits

6500DC Dual Motor Wireless Controller Kits 6500DC Dual Motor Wireless Controller Kits READ ALL DIRECTIONS FIRST BEFORE PROCEEDING NOTE: SEE THE QUICK PROGRAM INSTRUCTIONS BEFORE OPERATING THE FIRST TIME. DO NOT REMOVE THE TRANSMITTER BATTERY Please

More information

TRAC-Station BT Installation Instructions

TRAC-Station BT Installation Instructions TRAC-Station BT Installation Instructions P/N 10103024P1 November 2011 2011 UTC Fire & Security. All rights reserved. Introduction This is the Supra TRAC-Station BT Installation Instructions. Read these

More information

GLM SERIES CONTROL Users Manual Rev:

GLM SERIES CONTROL Users Manual Rev: GLM SERIES CONTROL Users Manual Rev: 808062 Connecting Power Page 2 Motor Terminal Wiring Diagrams Page 3 Getting Started / Setup Page 4 1. Obstruction Detection Devices Page 4 2. Checking Power and Direction

More information

Installation Instructions for ROFU Key Hole Mount Magnetic Locks

Installation Instructions for ROFU Key Hole Mount Magnetic Locks ROFU For Outswing Doors Installation Instructions for ROFU Key Hole Mount Magnetic Locks 808-LC, 808-B, 8-LC, 8-B, 8--LC, 8--B, 8-099 *See page for model specifications 009 S. Tacoma Way, E- -800--768

More information

C.E. Niehoff & Co. C653/C653A and C625 Alternators Troubleshooting Guide NOTICE. Hazard Definitions. Battery Charge Volt and Amp Values

C.E. Niehoff & Co. C653/C653A and C625 Alternators Troubleshooting Guide NOTICE. Hazard Definitions. Battery Charge Volt and Amp Values C.E. Niehoff & Co. C653/C653A and C625 Alternators Troubleshooting Guide Hazard Definitions These terms are used to bring attention to presence of hazards of various risk levels or to important information

More information

HGM1780 AUTOMATIC GENERATOR MODULE CONTENT 1. SUMMARY PERFORMANCE AND CHARACTERISTICS SPECIFICATION OPERATION...

HGM1780 AUTOMATIC GENERATOR MODULE CONTENT 1. SUMMARY PERFORMANCE AND CHARACTERISTICS SPECIFICATION OPERATION... CONTENT 1. SUMMARY...4 2. PERFORMANCE AND CHARACTERISTICS...4 3. SPECIFICATION...5 4. OPERATION...6 4.1. DISPLAY PANEL...6 4.2. LCD ICON INSTRUCTION...7 4.3. DISPLAY INSTRUCTIONS...7 4.4. DISPLAY DESCRIPTION...8

More information

5002/5005 Bike Repair Guide Version 2; Date:

5002/5005 Bike Repair Guide Version 2; Date: 5002/5005 Bike Repair Guide Version 2; Date: 10-26-04 5002 recumbent bike 5005 upright bike Note: Electronics in 5002 and 5005 are basically the same, but displays differ. Unique Technical Features of

More information

ST Charger. Industrial Battery Charger

ST Charger. Industrial Battery Charger ST Charger Industrial Battery Charger Installation and Operation Manual ST_13 Table of Contents Pg# 1.0 INSTALLATION 1 1.1 Receiving 1 1.2 Location 1 1.3 Line Voltage 1 1.4 A.C. Service Requirements 2

More information

Two Channel Remote Shutdown Device

Two Channel Remote Shutdown Device Installation & Operation Standard Features: Two Channel Remote Shutdown Device I. Introduction Latched shutdown for increased safety Powerful transmitter with 300 feet range Waterproof sealed transmitter

More information

INSTALLATION GUIDE. FCC ID NOTICE

INSTALLATION GUIDE.  FCC ID NOTICE REV.5 RS. ADVANCED REMOTE STARTER INSTALLATION GUIDE www.security.soundstream.com FCC ID NOTICE This device complies with Part 5 of the FCC rules. Operation is subject to the following conditions:. This

More information

TC62D Installation Instructions

TC62D Installation Instructions TC62D Installation Instructions January 2007 This TC62D has a return water low temperature limit option. Using the low limit precludes using a room sensor because both sensors plug into the same port.

More information

Model APS-25CH Installation Manual

Model APS-25CH Installation Manual Model APS-25CH Installation Manual Note : When both Passive Arming and Voltage Sensing are selected, you must hardwire the driver s do pin switch in der to begin the passive arming sequence. RF Programmable

More information

N1233 Series Troubleshooting Guide for N Alternator

N1233 Series Troubleshooting Guide for N Alternator N1233 Series Troubleshooting Guide for N1233-2 Alternator Hazard Definitions These terms are used to bring attention to presence of hazards of various risk levels or to important information concerning

More information

EA07. Generator Automatic Voltage Regulator Operation Manual

EA07. Generator Automatic Voltage Regulator Operation Manual EA07 Generator Automatic Voltage Regulator Operation Manual Suitable for Single or Three Phase Self Excited Brushless Generator Compatible replacement for Mecc Alte SR-7 * Not a genuine Mecc Alte product.

More information

MANUAL. MiniMax V / VK

MANUAL. MiniMax V / VK MANUAL CONTROL UNIT FOR ROTATING HEAT EXCHANGER MiniMax V / VK Revised 2014-10-07 Version 1.3.1 F21037901GB Declaration of Manufacturer The manufacturer s assurance of the agreement of the product with

More information

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS II 1400-10 ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS Features: Up to 1.95 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short Circuit Protection Standby Battery

More information

IRRIGATION 810-3T-PLUS TRANSMITTER GUIDE

IRRIGATION 810-3T-PLUS TRANSMITTER GUIDE IRRIGATION 810-3T-PLUS TRANSMITTER GUIDE Pg. 2 HOT SHOT OVERVIEW 3 STANDARD OPERATION MODE 4 HOW TO CONTROL AND SHARE MULTIPLE S 5 TRANSMITTER FUNCTION SWITCH SETTINGS 6 OPERATING THE TEST BEACON 7 OPERATING

More information

Solid-State Compass with GPS Receiver

Solid-State Compass with GPS Receiver Owner s Guide & Installation Instructions Solid-State Compass with GPS Receiver Model GH2183 Record the serial number found on the sensor. Serial No. Date of Purchase 17-489-01 rev. 01 04/22/08 1 WARNING

More information

MINE CHARGER INSTALLATION AND OPERATION MANUAL MODEL NUMBERS: MSP MSQ MSR MSS

MINE CHARGER INSTALLATION AND OPERATION MANUAL MODEL NUMBERS: MSP MSQ MSR MSS MINE CHARGER INSTALLATION AND OPERATION MANUAL MODEL NUMBERS: MSP MSQ MSR MSS Sec# Table of Contents Pg# 1 INSTALLATION 1.1 Receiving 1 1.2 Location 1 1.3 Line Voltage Adjustments 2 1.4 A.C. Service Requirements

More information

Model APS-25N Installation Manual

Model APS-25N Installation Manual Model APS-25N Installation Manual Note : When both Passive Arming and Voltage Sensing are selected, you must hardwire the driver s do pin switch in der to begin the passive arming sequence. RF Programmable

More information

3 Slot Payphone Controller

3 Slot Payphone Controller S Coin Controller 2A Information on your Telephone For Your Records Manufacturer Date of Original Manufacture Drawing Reference One of the original patents --- US 2,043,201 This Telephone is Property of

More information

280+ SHEARLOCK INSTALLATION AND WIRING MODELS: 280+ and 280+TRD TRD

280+ SHEARLOCK INSTALLATION AND WIRING MODELS: 280+ and 280+TRD TRD INSTALLATION AND WIRING MODELS: 280+ and 280+TRD 280+ Standard model is a concealed electromagnetic shear lock designed to fit standard hollow metal doors and frames. In cases where the top of the door

More information

SCHEMATIC AND ROUTING DIAGRAMS

SCHEMATIC AND ROUTING DIAGRAMS 2004 ACCESSORIES & EQUIPMENT Theft Deterrent - Corvette SCHEMATIC AND ROUTING DIAGRAMS THEFT DETERRENT SYSTEM SCHEMATICS Fig. 1: Theft Deterrent Relay, Security Indicator, Lighting and Horn References

More information

4500 Series Electric Exit Devices Request to Exit (RX) Installation Instruction Grade 1 I-ED00368

4500 Series Electric Exit Devices Request to Exit (RX) Installation Instruction Grade 1 I-ED00368 4500 Series Electric Exit Devices Request to Exit (RX) Installation Instruction Grade 1 I-ED00368 DEVICES COVERED IN THESE INSTRUCTIONS: RX Request to Exit ELECTRICAL SPECIFICATIONS Note: SPDT mechanical

More information

ARC4000e 4 wheel compressor system w / 4 way Ride Pro controller

ARC4000e 4 wheel compressor system w / 4 way Ride Pro controller 350 S. St. Charles St. Jasper, In. 47546 Ph. 812.482.2932 Fax 812.634.6632 on the internet: www.ridetech.com ARC4000e 4 wheel compressor system w / 4 way Ride Pro controller 1 ARC5001 Compressor 1 CON6000

More information

SKC400U SLIDING GATE OPENER OWNER S MANUAL

SKC400U SLIDING GATE OPENER OWNER S MANUAL SKC400U SLIDING GATE OPENER OWNER S MANUAL IMPORTANT SAFTEY INFORMATION Installing the SKC400U Gate Opener requires wiring of standard 110V electrical lines. This should only be performed by a trained

More information

* * E996L Series. E996L for Rim/Vertical. E996L for Mortise CAUTION

* * E996L Series. E996L for Rim/Vertical. E996L for Mortise CAUTION *921297-00* 921297-00 Electric Locking Trim E996L Series Installation Instructions CAUTION Product is shipped in Fail Safe (FS) configuration. Fail Safe configuration is required by code in some applications

More information

6R / 5-BUTTON SERIES VEHICLE SECURITY SYSTEM

6R / 5-BUTTON SERIES VEHICLE SECURITY SYSTEM 6R / 5-BUTTON SERIES VEHICLE SECURITY SYSTEM Button 1 Button 2 Button 5 Button 3 Button 4 Standard Features: Two 5-Button Remote Transmitters Status indicator (LED) Valet / override switch Multi-tone siren

More information

Instruction Manual for the. E-SL 450 Series

Instruction Manual for the. E-SL 450 Series Instruction Manual for the E-SL 450 Series Estate Slide Summary of Functions The Estate Slide is only to be used for vehicular Slide gates in a Class I setting. Class I: A vehicular gate opener (or system)

More information