Installation Instructions for Slide Mount Magnetic Locks
|
|
- Marcus Skinner
- 5 years ago
- Views:
Transcription
1 ROFU For Outswing Doors Installation Instructions for Slide Mount Magnetic Locks 8606, 8608 and 8612 Series *See page 2 for model specifications R Find the paper installation template included with the magnet (you will need this). Fold it on the dotted line. The rubber washer helps the armature plate to pivot s it should NOT be tightened all the way to door. Place the folded template in the proper position on the door/jamb and mark the holes you will cut for your magnet and armature plate. (Using tape will help) Adjustable Attach the mounting plate with the provided Phillips screws. Then the position of the mounting plate should still be adjustable. (Sample drawing as 8612 series mounting plate) Drill the holes according to the marks you made. Wiring 4 (Check Twice! Drill Once!).. Install the armature plate as shown in the drawing to the left. Attach the mounting plate to the jamb with included mounting Phillips screws as shown. (Sample drawing as 8612 series magnet & mounting plate) The actual dimensions of the holes are illustrated below. Hollow Metal Door Solid Door Use the Allen wrench and thru-bolts to tighten the magnet to the mounting plate. 1 7/16 Allen Wrench 1/2 5/16 1/2 5/16 Drill a 5/16 (8mm) hole through the door for the armature side. For the sexnut side (secure side), enlarge the hole to 1/2 (12.7mm) for the width of the sexnut. On wood doors the depth of the sexnut is 1 7/16 (36mm). Outswing Door Connect the power and test the holding force. Add washers if there is still a gap between the magnet and armature plate. Wires (Sample drawings above as 8612 series magnet & mounting plate) (1) Pass the wiring through the mounting plate and into the wiring hole at the top of the magnet and into the PCB area. (2) Slide the magnet onto the mounting plate. (3) Once into proper position, tighten the thru-bolts from the bottom of the magnet into the mounting plate using the included Allen wrench. Allen Wrench 1
2 ROFU Z-bracket for Inswing Doors Find the correct mounting position on the door jamb for the L-bracket. Ensure that the door still closes with it in position. Use the thru-bolt to install the magnet onto the L-bracket. Assemble the Z-bracket, but not too tight as it needs to remain adjustable for now. Insert the roll pins into the armature plate Finish Outdoor Outdoor Attach the armature plate and washers to the Z-bracket assembly. Specifications Close the door and connect the power. Voltage: 12/24 VDC Selectable Current Draw: 500 ma /12VDC, 250 ma / 24VDC Holding Force: 600 lbs, 600lbs, 800lbs, 800lbs, 1200 lbs, 1200 lbs Dimensions: 8606-B/BD: (600 lbs) Magnet: 9 13/16" 13/16" " ( mm) : 7 1/4" 1/2" /2" (185 x 38 2mm) BD: (600 lbs ) Magnet: 19 11/16" 13/16" " ( mm) s (each side): 7 1/4" 1/2" /2" (185 x 38 2mm) 8608-LC/B/BD: (800 lbs) Magnet: 10 7/16" 1/16" 1/8" ( mm) : 7 1/4" 3/4" x 9/16" ( mm) B/BD: (800 lbs ) Magnet: 20 7/8" 1/16" 1/8" ( mm) s (each side): 7 1/4" 3/4" x 9/16" ( mm) 8612-LC/B/BD (1200 lbs) Magnet: 10 1/2" 13/16 " 9/16" (267 x 71 0mm) : 7 1/4" 3/8" /8" (185 x 616mm) B/BD: (1200 lbs ) Magnet: 21" 13/16" 9/16" (533 x 71 0mm) s (each side): 7 1/4" 3/8" /8" (185 x 616mm) After the magnet engages the armature plate, you can now adjust the Z-bracket, and attach to the door. Ensure all screws of Z-bracket are tighten to door. We encourage the use of thread locker (LocTite). Model Changes to ROFU ic Locking Devices 86 XX (LC/BD/B) - (US28/40)(12/24) Holding Force: 06 = 600 lbs (Mini) 08 = 800 lbs (Midi) 12 = 1200 lbs (Standard) Functions: LC = Low cost (NO MONITORING) BD = Bond sensor, LED & Door status B = Bond sensor & LED only 2 = Double Magnet OR NOTHING THERE 6 = Slide mounting plate magnetic lock series MAGLOCK SERIES 12/24: 12/24 VDC Selectable Finish: US28 Satin Aluminum or US40 Duronatic / Dark Anodized Bronze (Limited Availability for US40) 8600 Series Diagrams of Magnets & Mounting s 8606-B, 8606-BD 8608-LC, 8608-B, 8608-BD 8612-LC, 8612-B, 8612-BD (600 lbs.) (800 lbs.) (1200 lbs.) BD B, BD B, BD (600 lbs. ) (800 lbs. ) (1200 lbs. ) 2
3 Wiring Diagram for 8606 and 8608 Series Single Magnet Models Supply PB contact output: Open / Not bonding status. contact output: Locked / Bonded status. Keypad/Reader Orange: White: Brown: Indicates the door is in and open or closed status. Reed switch rated 0.2A/12VDC supply Input For 8608-LC Wiring Wiring Diagram for 8612 Series Single Magnet Models supply PB Keypad/Reader contact output: Open / Not bonding status. contact output: Locked / Bonded status. Indicates the door is in and open or closed status. Reed switch rated 0.2A/12VDC Orange: White: Brown: supply For 8612-LC Wiring Input Voltage Selection Jumpers - ROFU recommends a good maintenance schedule! - Please ensure all armature bolts and mounting bolts are checked quarterly. - ROFU recommends using Loctite (Thread locker) on ALL bolts during installation. - Current Draw: 500 ma /12VDC, 250 ma / 24VDC per block 3
4 Wiring Diagram for BD and BD Double Magnet Models Supply PB contact output: Open / Not bonding status. contact output: Locked / Bonded status. Keypad/Reader Orange: White: Brown: Indicates the door is in and open or closed status. Reed switch rated 0.2A/12VDC Orange: White: Brown: Wiring Diagram for B/BD Double Magnet Models Supply PB Keypad/Reader contact output: Open / Not bonding status. contact output: Locked / Bonded status. Orange: White: Brown: Indicates the door is in and open or closed status. Reed switch rated 0.2A/12VDC Orange: White: Brown: 4
5 Installation Diagram & Screw Pack Components (Sample drawings of 8606-B & B magnet & assemblies) Mounting Mounting Cover Screw Screw Mounting Screw Mounting Screw Cover Components 8606-B 8608-B 8612-B 8608-LC 8612-LC B B Thru-s (5/32"5/32") (1/4" 21/32") (1/4" 21/32") Phillips Flat Head Screws (5/32" ") (11/32" 9/32"/32") (11/32" 9/32"/32") 0 0 Allen Flat Head Screw (5/16" 3/8") (5/16" ") (5/16" 3/8") (5/16" ") (5/16" 3/8") Hexagon Key (Allen Wrench) (1/8") (1/2" 9/16") (1/2" 9/16") 5
6 Installation Diagram & Screw Pack Components (Sample drawings of 8606-BD & BD magnet & assemblies) Mounting Mounting Cover Screw Screw Screw Mounting Screw Cover Mounting Holder Holder Holder Components 8606-BD 8608-BD 8612-BD BD BD BD Thru-s Phillips Flat Head Screws (5/32"5/32") (1/4" 21/32") (5/32" 5/32") (1/4" 21/32") (5/32" ") x 6 (11/32" 9/32"/32") (9/16" 3/16" /32") (5/32" ") 2 (11/32" 9/32" /32") (9/16" 3/16" /32") Allen Flat Head Screw (5/16" 3/8") (5/16" ") (5/16" 3/8") (5/16" 3/8") (5/16" ") (5/16" 3/8") Hexagon Key (Allen Wrench) (1/8") (1/8") (1/2 9/16 ) (1/2 9/16 ) 6
Installation Instructions for ROFU Key Hole Mount Magnetic Locks
ROFU For Outswing Doors Installation Instructions for ROFU Key Hole Mount Magnetic Locks 808-LC, 808-B, 8-LC, 8-B, 8--LC, 8--B, 8-099 *See page for model specifications 009 S. Tacoma Way, E- -800--768
More informationSTANDARD / DOUBLE STANDARD MAGNETIC LOCK
STANDARD / DOUBLE STANDARD MAGNETIC LOCK INSTALLATION MANUAL INDOOR ELECTROMAGNETIC LOCK SERIES Spec/Model GEM-300 Single GEM-600 GEM-800 GEM-1200 Double GEM-D600 GEM-D800 GEM-D1200 Holding Force 300lbs
More informationMODEL 600LB 600 POUND SINGLE MAGNETIC LOCK WITH LED, BOND SENSOR & DOOR STATUS SENSOR SPECIFICATIONS
MODEL 600LB 600 POUND SINGLE MAGNETIC LOCK WITH LED, BOND SENSOR & STATUS SENSOR SPECIFICATIONS U.L. LISTED, LISTING NUMBER R16759 600 POUND MINIMUM HOLDING FORCE MAGNET SIZE 9-7/8 L x 1-11/16 H x1 W SIZE
More informationINSTALLATION INSTRUCTIONS E300 SERIES MAGNETIC CABINET/DISPLAY CASE LOCK
801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS E300 SERIES MAGNETIC CABINET/DISPLAY CASE LOCK The E300 Series magnetic
More informationMODEL 1200S MAGNETIC LOCK
MODEL 1200S MAGNETIC LOCK SPECIFICATIONS U.L. LISTED, LISTING NUMBER R16759 1200 POUND MINIMUM HOLDING FORCE MAGNET SIZE 10-1/2 L x 2-7/8 H x1-1/2 W 12 OR 24 VOLT DC OPERATION, JUMPER SELECTABLE CURRENT
More informationMODEL 1200S MAGNETIC LOCK
MODEL 1200S MAGNETIC LOCK SPECIFICATIONS U.L. LISTED, LISTING NUMBER R16759 1200 POUND MINIMUM HOLDING FORCE MAGNET SIZE 10-1/2 L x 2-7/8 H x1-1/2 W 12 OR 24 VOLT DC OPERATION, JUMPER SELECTABLE CURRENT
More informationMODEL 600S 600 POUND SINGLE MAGNETIC LOCK SPECIFICATIONS
MODEL 600S 600 POUND SINGLE MAGNETIC LOCK SPECIFICATIONS U.L. LISTED, LISTING NUMBER R16759 600 POUND MINIMUM HOLDING FORCE MAGNET SIZE 9-7/8 L x 1-11/16 H x1 W SIZE 5-1/2 L x 1-1/4 W x 7/16 D 12 OR 24
More informationMODEL 600LB 600 POUND SINGLE MAGNETIC LOCK WITH LED, BOND SENSOR & DOOR STATUS SENSOR SPECIFICATIONS
MODEL 600LB 600 POUND SINGLE MAGNETIC LOCK WITH LED, BOND SENSOR & STATUS SENSOR SPECIFICATIONS U.L. LISTED, LISTING NUMBER R16759 600 POUND MINIMUM HOLDING FORCE MAGNET SIZE 9-7/8 L x 1-11/16 H x1 W SIZE
More information8. Do not install this product on the exterior of buildings. 9. Do not use as a doorstop. This will void warranty. Installation Instructions
INSTALLATION 8310-IQ/8320-IQ IntelliMag Electromagnetic Locks Pre-Installation Instructions 1. This product must be installed according to all applicable building and life safety codes. 2. Due to the variety
More informationWith LED, Bond Sensor E-941SA-600PQ 600-lb. (272kg) E-941SA-1K2PQ 1200-lb. (545kg) Weatherproof E-941SA lb.
Electromagnetic Lock E-941SA-600 600-lb. (272kg) E-941SA-1200 1200-lb. (545kg) With LED, Bond Sensor E-941SA-600PQ 600-lb. (272kg) E-941SA-1K2PQ 1200-lb. (545kg) Weatherproof E-941SA-300 300-lb. (136kg)*
More informationPre-Installation Instructions
BML-8371 and BML-8372 Electromagnetic Locks Spanish and French translations are available on www.bestaccess.com Traducciones al español y francés están disponibles en www.bestaccess.com Des traductions
More informationInstallation Instructions
I N S T A L L A T I O N 8310/8320 8330/8340 Electromagnetic Locks Pre-Installation Instructions 1. This product must be installed according to all applicable building and life safety codes. 2. Due to the
More informationV2M1200/1290 Series Maglock Installation Instructions
Securitron Phoenix, AZ 85044 Tel: 1-800-624-5625 Mon-Fri: 6:00am - 4:00pm PDT Fax: 1-800-232-7329 www.securitron.com V2M1200/1290 Series Maglock Installation Instructions 1 Table of Contents Product Information...
More information1-3/4" MOUNTING INSTRUCTIONS: 1150 SERIES SURFACE MOUNTED 1500 LB. ELECTROMAGNETIC LOCK
MOUNTING INSTRUCTIONS: 1150 SERIES SURFACE MOUNTED 1500 LB. ELECTROMAGNETIC LOCK FULL WIDTH STOP WITH SURFACE MOUNT ARMATURE Model Numbers: 1150, 1152 & 1155 READ THOROUGHLY BEFORE INSTALLING HEADER STOP
More informationMAGNETIC LOCKS SERIES OPTIONS (ADD TO LOCK): xl. ADD 1 LED (BICOLOR RED / GREEN) xd. ADD SPDT DOOR POSITION SWITCH (SINGLE) x2d
1100 SERIES OPTIONAL MAGNETIC LOCK FEATURES 1100 SERIES OPTIONS (ADD TO LOCK): xl ADD 1 LED (BICOLOR RED / GREEN) xd ADD SPDT DOOR POSITION SWITCH (SINGLE) x2d ADD 2 SPDT DOOR POSITION SWITCHES (1115/1120/1152/1155)
More informationINSTALLATION 8310/8320
INSTALLATION 8310/8320 Electromagnetic Locks Pre-Installation Instructions 1. This product must be installed according to all applicable building and life safety codes. 2. Due to the variety of mounting
More informationInstructions For PG-1200RC Magnetic Locking Devices
Instructions For PG-1200RC Magnetic Locking Devices (Remote control distance up to 10 meters) Ver. 18.1 Please Read Carefully Before Installing Magnetic Lock A. Carefully for handling to prevent damage
More informationExcel Series Value Engineered Access Hardware
Excel Series Value Engineered Access Hardware Excel E1200 Economically Priced Alternative to Low Cost Imports Quality and Flexibility for Commercial Applications. The Excel product line is designed for
More informationM670/M680BD MAGNALOCK SERIES Installation Instructions
Securitron www.securitron.com Tel 800.624.5625 techsupport@securitron.com M670/M680BD MAGNALOCK SERIES Installation Instructions Page 1 Rev. D, 12/14 Table of Contents Package Contents... 3 Mounting Hardware...
More informationMODEL 3002xTJ32 ELECTROMAGNETIC LOCK INSTALLATION INSTRUCTIONS
The Series 3002xTJ32 is a 1500 pound holding force top jamb mounted electromagnetic lock designed to secure a double inswing door. The lock requires both installation procedures as described herein and
More informationMODEL 1200LB 1200 POUND MAGNETIC LOCK WITH LED, BOND SENSOR & DOOR STATUS SENSOR
MODEL 1200LB 1200 POUND IC LOCK WITH LED, BOND SENSOR & STATUS SENSOR U.L. LISTED, LISTING NUMBER R16756 1200 POUND MINIMUM HOLDING FORCE SIZE: 10-1/2 L x 2-7/8 H x 1-1/2 W SIZE: 7-3/8 L x 2-3/8 W x 9/16
More informationElectromagnetic Locking Solutions
Electric Mortice Locks ing Solutions Z Series Single Non Monitored EML 52 Z Series Single Monitored EML 54 Z Series Double Non Monitored EML 56 Z Series Double Monitored EML 58 Z Series Recessed EML 60
More informationcel SECURITY DOOR CONTROLS Value Engineered Access Hardware sdcsecurity.com Power Supplies Exit Switches
Security Door Controls cel TM Value Engineered Access Hardware Excel E1200 Excel E600 Excel E300 Excel Series Value Engineered Access Hardware from SDC Economically Priced Alternative to Low Cost Imports
More informationPackage Contents. Mounting Hardware
Securitron Magnalock Corp. www.securitron.com Tel 800.624.5625 techsupport@securitron.com M680BDCX MAGNALOCK SERIES Installation Instructions Table of Contents Specifications 2 Configuring Options 3 Installation
More informationLOCKNETICS MagForce+ Series. Locknetics MagForce Traffic Control Magnet MEA
Locknetics MagForce+ Locknetics new MagForce Plus generation of electromagnetic locks is the evolution of the industry leading 390 Series.The MagForce Plus family consists of the 390+ with 1650 lbs of
More information280+ SHEARLOCK INSTALLATION AND WIRING MODELS: 280+ and 280+TRD TRD
INSTALLATION AND WIRING MODELS: 280+ and 280+TRD 280+ Standard model is a concealed electromagnetic shear lock designed to fit standard hollow metal doors and frames. In cases where the top of the door
More informationE-941SA-300RQ. Manual. 300-lb Single-Door Electromagnetic Lock with Reversible Magnet
E-941SA-300RQ 300-lb Single-Door Electromagnetic Lock with Reversible Magnet Manual Reversible magnet for left or right-swing doors. Perfect for cabinets, small enclosures, or pedestrian gates. Selectable
More informationINSTALLATION EML375. Pre-Installation Instructions. Electromagnetic Locks
INSTALLATION EML375 Electromagnetic Locks Pre-Installation Instructions PLEASE DELIVER ALL INSTALLATION INSTRUCTIONS TO THE END-USER UPON COMPLETION OF THE INSTALLATION. 1. This product must be installed
More informationMagForce+ The Positive Force in Electromagnetic Locks
MagForce+ The Positive Force in Electromagnetic Locks 390+ 320+ 350+ The MagForce+ Family 390+ 320+ 350+ MADE IN THE USA MEA 11-95-E Locknetics new MagForce Plus generation of electromagnetic locks is
More informationINSTALLATION DESCRIPTION
The Series 2011xTJ20 / 3000LCxTJ20 is a 1200 pound holding force top jamb-mounted electromagnetic lock designed to secure a single-inswinging door. The lock requires both installation procedures as described
More information8. Do not install this product on the exterior of buildings. 9. Do not use as a doorstop. This will void warranty.
INSTALLATION 8375 Surface MicroMag Electromagnetic Lock Pre-Installation Instructions 1. This product must be installed according to all applicable building and life safety codes. 2. Due to the variety
More informationR F O U PRICE LIST 2016
ROFU PRICE LIST 2016 ROFU ELECTROMAGNETS... 4 ELECTRIC STRIKES... 13 EXIT DEVICES... 19 MISC. ACCESS CONTROL... 23 TERMS & CONDITIONS... 25 TABLE OF CONTENTS ELECTROMAGNETS 8000 SERIES SHEAR LOCKS ROFU
More informationElectromagnetic locks - Single Doors
ELECTRONIC LOCKING further information section 8 Electromagnetic locks - Single Doors 3 General Description Face to face magnetic locks surface mount on the underside of the head frame, with the armature
More informationASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY
00 Series Power Operator Installation and Instruction ASSA Manual ABLOY Item No. Description Motor (00M) Cover (00COV) Control Inverter (00IN) Power Supply VDC (00PS) Track Assembly (0-) / Replacement
More information5600 Series Power Operator Installation and Instruction Manual
5600 Series Power Operator Installation and Instruction Manual 80-956-000-00 (08-) 5 ASSA ABLOY 6 Item No. Description Motor (5600M) Cover (5600COV) Control Inverter (5600IN) Power Supply VDC (5600PS)
More informationFIRE/LIFE SAFETY CLOSERS/HOLDERS SERIES
FIRE/LIFE SAFETY CLOSERS/HOLDERS SERIES PRODUCT SELECTION GUIDE SENTRONIC Series LCN closer/holders combine heavy duty closers with electrically controlled hold-open functions to control fire and smoke
More informationAccessories 286 SDC SECURITY DOOR CONTROLS
8 Security Door Controls From wireless remote controls to durable door holding & release devices, to REX sensors, timers, ball and magnetic switches, and from concealed contact to universal mounting enclosure
More informationEMLock 1500 Series. MEA Listed
EMLock 1500 Series SDC s patented EMLock design represents the pinnacle of magnetic lock evolution. The modular EMLock assembly makes them easy to stock, install, upgrade and maintain. Patented SDC 1500
More informationStandard Auxiliary L-Brackets & LZ-Brackets
L/LZ-Brackets Standard Auxiliary & LZ-Brackets L-Bracket L-Bracket Armature Z-Bracket Frame What is L- Bracket? L- Bracket is used as an extension on narrow door frames to provide adequate mounting surface
More informationARCHITECTURAL DOOR HARDWARE DOOR STOPS & HOLDERS THRESHOLDS & GASKETING CATALOG
ARCHITECTURAL DOOR HARDWARE DOOR STOPS & HOLDERS THRESHOLDS & GASKETING CATALOG January 1, 2017 v3 West Coast Office (800) 544-4422 East Coast Office (800) 225-6737 intldoorclosers.com Index DOOR STOPS
More informationELECTRONIC ACCESS CONTROL PRODUCT CATALOG
ELECTRONIC ACCESS CONTROL PRODUCT CATALOG Rutherford Controls Int l is a member of the dormakaba Group, one of the top 3 providers for access and security solutions in the global market. ELECTROMAGNETIC
More information!!!! ! Lock housing dimensions: 230mm L x 44mm W x 44mm D! Receptacle housing dimensions: 120m L x 44mm W x 44mm D. ! Surface mount housing for LK120
ELECTROMAGNETIC LK120 Bolt Action Lock SP (Fail Safe) Fail-Safe: Strike Plate: Bolt Stainless Steel: 200(L) x 32(W) x 40(D) mm 90(L) x 26(W) x 2(D) mm 15.5mm Diameter, 17mm Throw 12V Operation Operation
More informationROFU International Corporation
ROFU International Corporation Suggested List Prices & Mini Catalog Prices Effective April 01, 2013 Replaces All Previous Pricelists (updated May 2014) Still your obvious choice for Electric Strikes, Magnetic
More informationTrine-Electric Strikes & Accessories
001 - Elecrtic Strike For use in new or replacement installations in wood and metal jambs. For use with locksets having up to 5/8 throw.* FACE PLATE 1-1/4 X 5-7/8 SATIN CHROME US26D VOLTAGE CURRENT AMPS
More informationElectromagnetic Locks Indoor GEM Series
Electromagnetic Locks Indoor GEM Series New Style Mounting Plate Design and Patented GEM NF S -937 The GEM series electromagnetic locks use a new style mounting plate and patented. The mounting plate is
More informationFIRE/LIFE SAFETY SERIES PRODUCT SELECTION GUIDE
FIRE/LIFE SAFETY SERIES PRODUCT SELECTION GUIDE SENTRONIC Series LCN closer/holders combine heavy duty closers with electrically controlled hold-open functions to control fire and smoke barrier doors.
More informationInstallation and Service Manual
RESIDENTIAL PLATFORM LIFTS RPL400 / RPL600 Installation and Service Manual WARNING! STRICT ADHERENCE TO THESE INSTALLATION INSTRUCTIONS IS REQUIRED to promote the safety of those installing this product,
More informationSecurity Door Controls
Security Door Controls 801 Avenida Acaso, Camarillo, ca. 930 (805) 494-0622 Fax: (805) 494-8861 www.sdcsecurity.com E-mail: service@sdcsecurity.com 1575-1576 EMLOCK R INSTALLATION INSTRUCTIONS During installation,
More informationFitting Instructions. Armlock 1354 Mini Electro-Shearmagnet (Surface) Contents
Fitting Instructions Armlock 1354 Mini Electro-Shearmagnet (Surface) Contents Before You Start...page 1 Installation instructions for wood, aluminium and glass...page 2 Wiring Diagram...page 3 Wiring and
More information4000 Series mounted closers
4000 mounted closers APPLICATIONS n For aluminum, hollow metal, or wood swinging doors and frames. n Can be used with hinge or pivot mounted door. n Adapter plates and other installation accessories available
More informationElectromagnetic Locks Weatherproof Series
Electromagnetic Locks The Ultimate in GE Electromagnetic Locks for Indoor/Outdoor Security The GE family of Weatherproof series electromagnetic locks are specifically designed for high profile openings
More information* * M400 Series. Features. Models. Trims. UL Requirements. Single Electromagnetic Locks: M420, M450, M490. Installation Instructions
*44487296* M400 Series 44487296 Single Electromagnetic Locks: M420, M450, M490 Installation Instructions M420/M450 Armature plate assembly M490 Armature plate assembly Features Automatic Voltage Selection
More informationASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY
0 Series Power Operator Installation and Instruction ASSA Manual ABLOY Item No. Description Motor (00M) Cover (00COV) Control Inverter (00IN) Power Supply VDC (00PS) / Replacement Motor Key (00KEY) Rod
More informationRequirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING
CAUTION 80-957-00-00 (08-0) Series 570 Openings 85 to 0 or to 70 Double Lever Arm Application for Frame Reveals (76) to 7 (78mm)* Stop (Push) Side of Installation 5700 LEO Operator Installation Instructions
More informationlkm7001 key override module Installation Instructions Converting The LKM7000 to The LKM7003
lkm7001 Instructions Converting The LKM7000 to The LKM7003 key override module In A Single Motion, We ll Change The Way You Think About Security Read Instructions thoroughly prior to installation Base
More informationHANDLING MECHANICAL INSTALLATION
2 INSTALLATION DESCRIPTION The and 2 Delay Egress Systems are 1500 pound holding force (holding force not evaluated by UL) per leaf electromagnetic locks, electronically controlled to provide a 15 or 30
More information12V / 24V Magnetic Gate Lock 1200lbs with Brackets
1200lbs with Brackets Electro-magnetic door locks are the most convenient and effective way to achieve secure access control. This lock is rated at 1200 pounds holding force with a door sensor and is supplied
More informationINSTALLATION INSTRUCTIONS MINI EXIT CHECK DELAYED EGRESS EMLOCK 1581S
SECURITY DOOR CONTROLS 3580 Willow Lane, Westlake Village, CA 91361-4921 (805) 494-0622 Fax: (805) 494-8861 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS MINI EXIT CHECK
More informationElectromagnetic Lock Reference Chart
Electromagnetic Lock Reference Chart INTELLIGENT LOCKS SPECIAL APPLICATION LOCKS MODEL 101+ 390DEL 390PIR 280+ 320M 390G+ GF3000 MAGFORCE MAGFORCE MAGFORCE SHEAR LOCK MINILINE GATE LOCK SHEAR LOCK DELAYED
More information99-03 V6 "Shaker" System Instructions. *03 Model requires new hood Contents w/ Kit. Tool List For Appliqué:
99-03 V6 "Shaker" System Instructions *03 Model requires new hood Contents w/ Kit 1 - Hood Appliqué 1 - Aluminum Shaker Scoop 1 - Lower Air Box w/drain tube fittings (2) 1 - Upper Air Box w/cdc nameplate
More informationWORX RACING YAMAHA STEERING STEM PART # - WR06030
WORX RACING YAMAHA STEERING STEM PART # - WR06030 MODELS: All YAMAHA FX Models 2012+ INSTALLATION INSTRUCTIONS IMPORTANT: READ ALL INSTRUCTIONS BEFORE PROCEEDING WITH INSTALLATION 1- Make sure ski is secure
More informationSEM SERIES FEATURES SEM 7820 MAGNET SEM FEATURES
SEM 7820 MAGNET Die Cast, Floor mounted. SEM 7820 Total Projection = 6-3/4 (171 mm) SEM SERIES The Sentronic SEM 7800 Series are heavy duty, electrically controlled door holding magnets. Magnets are fail
More informationJACKSON CORPORATION Series
Introduction The Jackson Grade 2 Overhead Concealed Closer has been the leader in the industry for over 35 years.the closer is manufactured in the U.S.A. under strict ISO 9000 guidelines and is designed
More informationPre-Installation Instructions
Pre-Installation Instructions 1. This product must be installed according to all applicable building and life safety codes. All installations must be approved by the Authority Having Jurisdiction (AHJ).
More informationCM5100 COMPUTER MANAGED CYLINDRICAL LOCK HARD-WIRED (FSE/FSA) INSTALLATION MANUAL
The 5100 series lock is a stand-alone, microprocessor controlled, electromechanical locking system. The 5100 employs a heavy-duty mechanical design which is easy to install and highly reliable. The FSE
More information2965 Magnetic Shear Lock Installation Instructions
MAGNETIC SHEAR LOCK 2965 INSTALLATION INSTRUCTIONS REFER TO THE PROPER TEMPLATE ACCORDING TO THE TYPE OF DOOR AND FRAME APPLICATION. READ THESE INSTRUCTIONS AND STUDY THE TEMPLATE THOROUGHLY BEFORE BEGINNING
More informationIK - Installation Kit. The complete IK and IK2 kits offer substantial savings over purchasing the same items separately
IK - Installation Kit Securitron s original Installation Kit includes the following: SDG-1 Heavy Duty Drill Guide BPT-2 Blind Nut Placement Tool SB-1 Sex Bolt - 32/62/82 SD-375 T-Handle Hex Wrench SEP-1
More informationS (8.0) (5.15).551 (14.0) .275 (7.0) S100
Normally Closed & Normally Open S99.315 (8.0) 2.134 (54.2).203 (5.15) 2.134 (54.2).203 (5.15).535 (13.6).203 (5.15).551 (14.0).067 (1.7).787 (20.0).157 (4.0) Type Circuitry Action Actuator 54 627 SPDT
More informationElectrified Products TABLE OF CONTENTS. P Power Supply Power Transfers Pressure Sense Bars Proximity Cards & Keys...
TABLE OF CONTENTS A Adjustable Angle Bracket (2941/2942)... 6 Angle Brackets (2950 Series)... 9 Armature Mounting Plates (2950 Series)...7-8 C Coordinator Mounting Bracket (2950 Series)... 8 Concealed
More informationElectrified Products TABLE OF CONTENTS. P Power Supply Power Transfers Pressure Sense Bars Proximity Cards & Keys...
TABLE OF CONTENTS A Adjustable Angle Bracket (2941/2942)... 6 Angle Brackets (2950 Series)... 9 Armature Mounting Plates (2950 Series)...7-8 C Coordinator Mounting Bracket (2950 Series)... 8 Concealed
More informationReplacement Door Bottom for Pease style doors MD /16 Beige 6 $13.20
Triple fin vinyl seal Superior for uneven floors Triple Fin Aluminum & Vinyl Door Sweep MD05090 05090 36 Aluminum 6 $8.00 MD05173 05173 36 Dark Bronze 6 $10.20 Rigid vinyl with soft vinyl sweep Sticks
More informationLCN 9740 SERIES SINGLE DOOR, SURFACE MOUNT (PUSH) OFFSET PIVOT/BUTT HINGE
SINGLE DOOR, SURFACE MOUNT (PUSH) OFFSET PIVOT/BUTT HINGE 9740 series operator is shipped with motor gearbox, control box, regular arm, header, and mounting hardware. Actuators available separately, see
More informationRequirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING
CAUTION 80-957-00-00 (08-0) Series 570 Door Openings 85 to 0 or to 80 Adjustable Arm and Slide Track Application Maximum Hinge Side Frame Reveal to /8 (mm) Hinge (Pull) Side of Door Installation 5700 LEO
More informationLegacy Installation Manual
Staying Home Corporation 1503 Vine Street P.O. Box 37 Harrisonville, MO 64701 816.380.2427 www.stayinghome.com A. INSTALLATION SITE REQUIREMENTS Legacy Installation Manual I. PRELIMINARY CHECKS 115 VAC,
More informationElectric Strikes for Adams Rite Deadlatches and Cylindrical Locks
7100 Series for Adams Rite Deadlatches and Cylindrical Locks 7100 Series 111 Designed for use with Adams Rite deadlatches or cylindrical locksets with 1/2" [12.7 mm] to 5/8" [15.9 mm] latchbolt projection.
More informationElectric Dropbolts. Secure and Intelligent Bolts. Fail-Safe Series Functions. DPS & BSS Outputs. Fail-Secure Series Functions
Secure and Intelligent Bolts are mortise mounted and available in fail-safe and fail-secure mode. The Electric Dropbolt Fail-safe series electric dropbolts can be mounted horizontally or vertically and
More informationELECTROMAGNETIC LOCKS
Ahlra offers a complete range of access control devices and accessories, including electromagnetic locks, electric drop bolt, Wireless Electric Drop bolt, electric strikes, shear locks, electromechanical
More informationROTON CONTINUOUS GEARED HINGES TABLE OF CONTENTS. L Length Specifications B Bearing at Top...4 Bearing on Top...4 Bearing Replacement Kit...
TABLE OF CONTENTS B Bearing at Top...4 Bearing on Top...4 Bearing Replacement Kit... 10 C Center Punches... 10 Concealed Electric Monitoring... 5, 7 Concealed Electric Through-Wire... 5, 7 Concealed Electric
More information9540 SERIES FEATURES SINGLE DOOR, SURFACE MOUNT (PUSH) OFFSET PIVOT/BUTT HINGE
SINGLE DOOR, SURFACE MOUNT (PUSH) OFFSET PIVOT/BUTT HINGE 9540 SERIES The 9540 SENIOR SWING by LCN is an ADA door operator that is a two-in-one swing door operator. SENIOR SWING operators when activated,
More informationElectromechanical Door Solutions
We take the worry out of protecting what s valuable to you. Lockwood: no worries www.lockweb.com.au Padde joins Lockwood ASSA ABLOY has recently repositioned Padde by Lockwood into the Lockwood range with
More informationProduct Drive Cameron Park, CA PH: PRO LAUNCH INSTALLATION INSTRUCTIONS
12-228 4130 Product Drive Cameron Park, CA 95682 PH: 1.530.642.9488 VIEW INSTALLATION VIDEO AT www.worksconnection.com/prolaunch/ 12-228 PRO LAUNCH INSTALLATION INSTRUCTIONS We at Works Connection Inc.
More informationElectromagnetic Locks DORMA EML
Electromagnetic Locks DORMA EML DORMA EML-1000M Electromagnetic Lock The DORMA EML-1000M Series Grade 1 electromagnetic locks secure the most demanding openings with 1650 lb of holding force. This lock
More information1. Gently pry off the interior door trim. Clean out and remove any insulation from the original prehung system.
Before you can order your door system, you'll need to understand common ordering specifications including proper measurement techniques, door swing and handing as well as machining for specific hardware
More information8. Do not install this product on the exterior of buildings. 9. Do not use as a doorstop. This will void warranty. Installation Instructions
INSTALLATI DE8310 Delayed Egress Electromagnetic Locks Pre-Installation Instructions 1. This product must be installed according to all applicable building and life safety codes. All installations must
More informationLocking Devices. Electromagnetic Locks. Security Door Controls 8 SECURITY DOOR CONTROLS
1 Locking Devices Security Door Controls Locking Devices SDC s approach to effective Access and Egress Solutions for the control of door openings begins with wide-ranging product lines of Locking Devices,
More informationLCN SEM SERIES FEATURES. SEM 7820 MAGNET Die Cast, Floor mounted. SEM 7870 MAGNET Die Cast, Dual Sided Floor mounted. SEM FEATURES
SEM 7820 Die Cast, Floor mounted. SEM 7820 The Sentronic SEM 7800 Series are heavy duty, electrically controlled door holding magnets. FEATURES Magnets are fail safe and hold until the current is interrupted.
More informationVM300 Series. Electromagnetic Lock BRACKETS SPECS VM300
VM300 10027 S 51st St, Ste 102 Phoenix, AZ 85044 623.582.4626 www.securitron.com/vista Real value and reliability, at an economical price Proven quality and convenience from the market leader Versatility
More information2300 OPERATING/APPLICATION/INSTALLATION INSTRUCTIONS
2300 OPERATING/APPLICATION/INSTALLATION INSTRUCTIONS GENERAL The POWER ACCESS Model 2300 is an automatic door opener designed for opening and closing side hinged residential doors - both exterior and interior.
More informationLCN 9540 SERIES SINGLE DOOR, SURFACE MOUNT (PUSH) OFFSET PIVOT/BUTT HINGE
SINGLE DOOR, SURFACE MOUNT (PUSH) OFFSET PIVOT/BUTT HINGE The 9540 SENIOR SWING by LCN is an ADA door operator that is a two-inone swing door operator. SENIOR SWING operators when activated, opens doors
More informationELECTROMAGNETIC LOCKS
safety 17 18 SAFETY ELECTROMAGNETIC LOCKS 12500 Electromagnetic lock Micro series Version: for mortice fixing body in stainless steel protected against humidity Dimensions of the body (mm): 170 x 32 x
More informationLegacy Installation Manual
Staying Home Corporation 1503 Vine Street P.O. Box 37 3823 Harrisonville, MO 64701 816.380.2427 Asheville Hwy. Hendersonville, www.stayinghome.com NC 28791 Precision Stairlifts Mailing Address: 306 Number
More informationDynaLock 705 Emmett Street Bristol, CT Phone:(860) Fax:(860)
ELECTROMAGNETIC GATELOCK INSTALLATION INSTRUCTIONS PLEASE READ BEFORE INSTALLATION Familiarize yourself with the gate and post conditions prior to installation. The lock must rigidly mount to the gate
More informationHMD v Power Feed with Coolant HMD v Type I plug, Power Feed with Coolant
0925202 HMD925 20v Power Feed with Coolant 0925302 HMD925 20v Type I plug, Power Feed with Coolant b a 5 HOOKS TO COOLANT INDUCER 8 7 9 29 3 0b 0a 0 36 23 8 7 3 2b 2a 2 a 7 Part / Serial Number Label 33
More informationRECESSED MAGNALOCK MODEL M34R SERIES INSTALLATION AND OPERATING INSTRUCTIONS
Securitron Magnalock orp. www.securitron.com ASSA ABLOY, the global leader Tel 800.6.5625 techsupport@securitron.com in door opening solutions REESSED MAGNALOK MODEL M34R SERIES INSTALLATION AND OPERATING
More informationLIST PRICING Component & Part Options
Component & Part Options UPS Shipment Charges Standard Package $15 Net Oversized Package (over 3 ) $40 Net SureFit Shim Unit Kit 6/8 and 7/0 Unit Composite Shims $8 8/0 Unit Composite Shims $9 Jamb Only:
More information9140 SERIES FEATURES SINGLE DOOR, SURFACE MOUNT (PUSH) OFFSET PIVOT/BUTT HINGE
SINGLE, SURFACE MOUNT (PUSH) OFFSET PIVOT/BUTT HINGE 9140 SERIES The 9140 BENCHMARK by LCN is an electrically powered low-energy operator. It provides easy access for people with disabilities, or the elderly.
More informationSIGNETMARINE. Livewell Bait Pump Alarm. No Dead Bait.
B A I T WAT C H SIGNETMARINE Livewell Bait Pump Alarm No Dead Bait. The SIGNETMARINE BaitWatch System alerts you to a livewell pump problem before your fishing trip turns into one. The loud alarm and dual-color
More informationEURO VISTA FOLD. Approved for use in Miami-Dade HVHZ Zones Florida Building Code Approved Product Approval FL FOLDING SLIDING STACKING PIVOT
EURO VISTA FOLD IMPACT RATED Aluminum FOLDING Doors Approved for use in Miami-Dade HVHZ Zones Florida Building Code Approved Product Approval FL 17838 www.euro-wall.com 888.989.EURO (3876) FOLDING SLIDING
More informationArchiTech by Networx
ArchiTech by Networx FOR CYLINDRICAL LOCKS USING SURFACE-MOUNTED NETWORX CONTROL UNITS MOUNTING AND INSTALLATION INSTRUCTIONS NAPCO Security Technologies, Inc. 2014 WI2104 08/14 DESCRIPTION These instructions
More informationUser Guide. Asset Guard PW INSTALLATION GUIDE. Table of Contents GETTING STARTED... 2 HARDWARE MOUNTING... 3 DEVICE CONNECTIONS...
User Guide Asset Guard PW INSTALLATION GUIDE Table of Contents GETTING STARTED... 2 HARDWARE MOUNTING... 3 DEVICE CONNECTIONS... 4 1 GETTING STARTED Asset Guard PW Overview The Verizon Networkfleet Asset
More information