1 surefire SLR OPERATORS MANUAL Single Phase Models (2VDC, 115VAC and 20VAC)

2 Index General...2 Application Safety Precautions and symbols...2 Design and Construction Principle of Operation Technical Specifications... Overall Dimensions...-5 Wiring Diagram Terminal Block Connections Installation and Commissioning Maintenance and Service... Timer settings (for use with optional timer)... Hydraulic Diagram... Troubleshooting Wiring Diagram Timer Connections Spare Parts List How To Order General Before installing this lubricator, please read this manual carefully. Failure to follow these instructions can result in damage to the product and/or serious bodily injury. The SureFire SLR lubricator meets all of the operating parameters for Bijur Single Line Resistance (SLR) centralized lubricating systems. Copyright Bijur Lubricating Corporation Bijur Lubricating Corp. reserves the right to update or improve the technical specifications for this product without prior notice. Company Headquarters and Sales/Service: Bijur Delimon International 20 Gateway Centre Blvd., Suite Morrisville, North Carolina USA Phone: (00) Fax: (1) Application This SureFire SLR lubricator is ideally suited for use in single-line centralized lubrication systems. In these systems, lubricant is being delivered in pulses and under pressure (pressure and relief cycles) through the main feed lines to resistance fittings (metering units or control units) located near the lube points of the machinery being lubricated. Every use beyond this type of application is not in accordance with the manufacturers intended purpose, and the manufacturer is not to be held responsible for any damages resulting from it. The corresponding risk is taken by the user only. Safety This Operators Manual covers fundamental concepts, which are to be observed for installation, operation and maintenance. Therefore, it is absolutely necessary that the Operators Manual be studied by the person doing the installation prior to installation and start-up. It is also necessary to have this Operators Manual nearby and available for reference in the future. The safety instructions mentioned in this Operators Manual, as well as all national operating and safety regulations for the safe operation of such equipment are to be observed. Precautions and symbols General precautions and symbols used within this manual are as follows: General safety instructions Electrical safety instructions Safety instructions which shall be considered for reasons of safe operation of the lubricator Electrical connections made to Earth ground are identified by this symbol Electrical connections made to the Neutral conductor are identified with a capital N Conditions and actions that pose potential hazards to the user are marked by this sign All safety and/or warning labels affixed to the SureFire SLR lubricator must be maintained in a completely legible condition. Also, any modifications made to the SureFire SLR lubricator (or to any of its components) must be approved by Bijur Lubricating Corp. prior to its use, otherwise the warrantee and any liability by Bijur Lubricating Corp. will be null and void. Design and Construction The basic design of the SureFire SLR lubricator is that of a motor driven gear pump, which sits in a reservoir of lubricant. The motor, gear pump and connecting driveshaft are assembled as a self-contained unit and are dropped into the reservoir through a hole in the main structural component, the Top Plate. Installing the motor and pump assembly into the reservoir from the top provides easy access to all of the motor and pump components, including the screen (if applicable) without having to disassemble the reservoir. If detaching the reservoir from the Top Plate is necessary, it can be done easily and without any tools on all models other than the 12 liter models, by loosening the external latches that are located on either side of the lubricator. On all models other than the 12 liter models, the Top Plate is mounted to the customer equipment by means of two bolts, and also provides the mounting locations for all of the other lubricator components. The 12 liter models are supported from the bottom. The motor, pump and driveshaft assembly delivers pressurized lubricant directly into a channel in the Top Plate. This channel is sealed by means of O-Rings, and gives the Top Plate two integral outlet ports, one located at each end. Therefore, the customer may connect the main line plumbing distribution network to either side of the Top Plate, or to both sides, whichever is more convenient or aesthetically pleasing. N 2

3 Principle of Operation When power is supplied to the motor (via either an on-board timer or controller or by customer-supplied power) the motor runs the gear pump. As the motor turns, the gear pump pulls lubricant in from the reservoir and delivers pressurized lubricant to the distribution network via the outlet(s) in the Top Plate. Pressurizing the distribution network forces all of the resistance fittings in the system to discharge the lubricant to the friction points. As the resistance fittings discharge, the pressure in the network continues to rise until the limit in the pressure switch is reached (pressure switch sold separately). Once this limit is reached, the pressure switch can be used to stop the motor. Once the motor stops, momentary pressure in the distribution network is greater than the pressure at the outlet side of the gear pump. This pressure differential actuates a quick dump valve which relieves the distribution line pressure back into the reservoir. In the SureFire SLR models that come equipped with an on-board timer or controller, the frequency of the cycling is programmed automatically to be either time dependent or machine event dependent (ex. triggered by a proximity switch). Also, if the pressure switch ever becomes faulty, any over-pressure situation in the distribution network is always relieved back into the reservoir by means of a pressure relief valve set at a level safe for Bijur resistance fittings. A low-lubricant level switch is standard on all SureFire SLR controller models as well, and is used to prevent operation of the lubricator once the level of lubricant in the reservoir falls below a set minimum level. In this case, the motor is prevented from running and a fault condition on the controller is generated and/or a fault light is illuminated. Also, on all SureFire SLR models that have an on-board controller, the pressure building aspect of the system is monitored to detect if there might be a possible leak in the distribution system. More specifically, the time elapsed from the motor start event to the pressure switch event is monitored, and if too much time is taken between these two events, a leak in the distribution network is assumed, the motor is subsequently prevented from running and a fault condition on the controller is generated and/or a fault light is illuminated. On all SureFire SLR models that have an on-board controller, once a fault condition is generated, it is cleared by the next successful lube cycle and pressure switch actuation. All SureFire SLR models come with an LED that illuminates when the motor shaft is actually turning, and a Momentary On/Off Switch that can be wired for manual priming if the customer so desires. For all SureFire SLR models that come with an on-board timer or controller, the Momentary On/Off Switch is pre-wired at the factory. Technical Specifications Output Volume: 115VAC, 20 VAC: 60Hz 50 Hz) 2VDC: 250cc/min Output Pressure (MAX.): 5 psi (5 bar). This is the pressure relief valve setting. Pressure Switch: Optional, closes at 20 ±5 psi (1. ±0. bar). Standard on SLR controller series. Lubricant Viscosity: Oil, cp, Light Greases, NLGI , ,000 cp Output Connection to Distribution: G1/ BSPP (minimum 6MM OD main distribution line tubing recommended) Reservoir Fill Screen: 0 mesh, removable Reservoir Volume: 1. Liters, 2. Liters, 6.0 Liters, 12.0 Liters Reservoir Material: Clear ABS Plastic for 1., 2. and 6.0L, Steel for 12.0L Motor Voltage Options: 2VDC, 115VAC 50/60 Hz, 20VAC 50/60 Hz Motor Overload Protection needs to be provided by the host machine and/or its control system. Motor Power Requirements: Approx. W Motor Duty Cycle (for 115VAC and 20VAC motors): S, 20%. This means that the maximum continuous ontime for any cycle is minutes, and if the motor continuous ontime for a cycle is X, the required minimum offtime for that same cycle is at least 5X. Each motor has an internal high temperature cutoff switch. Motor Duty Cycle (for 2VDC motor): S1 (Continuous Duty). Operating Temperature Range: +5 C through +0 C (+0 F through +5 F) Sound Pressure: 0 dba IP Rating: IP-5 Dry Weights SF2AxxB or C or D:.0 lbs/.0 Kg SFAxxB or C or D:.0 lbs/.5 Kg SF6AxxB or C or D: lbs/5. Kg SF12AxxB or C or D: 16.0 lbs/.26 Kg Current Draw and Power Consumption Rated Voltage (+/- %) 2VDC 115 & 20VAC (60 Hz, 1 Phase) Peak Starting Current (amps) 2. 2./1.1 Normal Running Current (amps) /.5 Max. Current locked rotor (amps) 5.2.0/1. Discharge (cc/min) Hz 200/200 50Hz 16/16 NOTE: 1) Peak and Starting Currents were measured with 0,000cp fluid at 50 psi. output pressure. 2) Discharge flows were measured with 0 psi output pressure. The SureFire SLR lubricator must not be used in explosive atmospheres and must not be used for pumping flammable liquids.

4 Overall Dimensions SureFire SLR 1.L, 2.L, 6.0L (2VDC, 115VAC and 20VAC models) (on board timer or controller not available with 1.L reservoir size) (all dimensions are in millimeters) (todas las dimensiones estan en milímetros) (alle Abmessungen in Millimeter) (toutes les dimensions sont en millimètres) Language Language con con N C B A Language Language con con E F G K D H Q Q J P U R L N M T S T SureFire Reference A B C D E F G H J K L M N P Q R S T U 1.L N/A 2.L L N/A N/A

5 Overall Dimensions SureFire SLR 12.0L (2VDC, 115VAC and 20VAC models) (all dimensions are in millimeters) (todas las dimensiones estan en milímetros) (alle Abmessungen in Millimeter) (toutes les dimensions sont en millimètres) 5

6 Terminal Block Connections - 115VAC Oil Version 115VAC Ground / Tierra / Erde / La terre 0 Led / Conducido / Mené 1 115VAC (+) 2 (Do not use) / (no el uso) / (nicht verwenden) / (pas l'utilisation) 115VAC (-) 5 Led / Conducido / Mené 6 Pressure switch / Interruptor de presión / Druckschalter / Mano-contact Level switch/ Interruptor de nivel/ Füllstandschalter / Commutateur de niveau Momentary "on" switch/ Interruptor momentáneo de "on" 11 Momentschalter AN / Commutateur momentané de "on" 12 White/ Blanco/ Weiß / Blanc Blue/ Azul/ Blau/ Bleu Red/ Rojo/ Rot/ Rouge M (Customer option)/ (Opción del cliente)/ (Wahl des Kunden)/ (Option de client) 1 1 ENG (5) Jumpers as shown ESP (5) puentes según lo demostrado DE (5) Überbrückungsdrähte (Verbindungsleiter) wie gezeigt FR (5) pullovers comme montré Grease Version 115VAC ENG Level switch (N.O) ESP Interruptor de nivel (N.O) DE Füllstandschalter (N.O) FR Commutateur de niveau (N.O) Ground/ Tierra/ Erde/ La terre 0 Led/ Conducido/ Mené 1 115VAC (+) 2 (Do not use)/ (no el uso)/ (nicht verwenden)/ (pas l'utilisation) 115VAC (-) 5 Led/ Conducido/ Mené 6 Pressure switch/ Interruptor de presión/ Druckschalter/ Mano-contact...0VDC (+) Output (+) 200mA...0VDC (-) Momentary "on" switch/ Interruptor momentáneo de "on" 12 Momentschalter AN / Commutateur momentané de "on" 1 (Customer option)/ (Opción del cliente)/ (Wahl des Kunden)/ (Option de client) White/ Blanco/ Weiß / Blanc Blue/ Azul/ Blau/ Bleu Red/ Rojo/ Rot/ Rouge Brown/ Marrón/ Braun/ Brun Blue/ Azul/ Blau/ Bleu L+ L- M ENG (5) Jumpers as shown ESP (5) puentes según lo demostrado DE (5) Überbrückungsdrähte (Verbindungsleiter) wie gezeigt FR (5) pullovers comme montré 6

7 Terminal Block Connections - 20VAC Oil Version 20VAC Ground / Tierra / Erde / La terre 0 Led / Conducido / Mené 1 20VAC (+) 2 (Do not use) / (no el uso) / (nicht verwenden) / (pas l'utilisation) 20VAC (-) 5 Led / Conducido / Mené 6 Pressure switch / Interruptor de presión / Druckschalter / Mano-contact Level switch/ Interruptor de nivel/ Füllstandschalter / Commutateur de niveau Momentary "on" switch/ Interruptor momentáneo de "on" 11 Momentschalter AN / Commutateur momentané de "on" 12 White/ Blanco/ Weiß / Blanc Blue/ Azul/ Blau/ Bleu Red/ Rojo/ Rot/ Rouge M (Customer option)/ (Opción del cliente)/ (Wahl des Kunden)/ (Option de client) 1 1 ENG () Jumpers as shown ESP () puentes según lo demostrado DE () Überbrückungsdrähte (Verbindungsleiter) wie gezeigt FR () pullovers comme montré Grease Version 20VAC Ground / Tierra / Erde / La terre 0 Led / Conducido / Mené 1 20VAC (+) 2 (Do not use) / (no el uso) / (nicht verwenden) / (pas l'utilisation) 20VAC (-) 5 Led / Conducido / Mené 6 Pressure switch / Interruptor de presión / Druckschalter / Mano-contact Level switch/ Interruptor de nivel/ Füllstandschalter / Commutateur de niveau Momentary "on" switch/ Interruptor momentáneo de "on" 11 Momentschalter AN / Commutateur momentané de "on" 12 White/ Blanco/ Weiß / Blanc Blue/ Azul/ Blau/ Bleu Red/ Rojo/ Rot/ Rouge M (Customer option)/ (Opción del cliente)/ (Wahl des Kunden)/ (Option de client) 1 1 ENG () Jumpers as shown ESP () puentes según lo demostrado DE () Überbrückungsdrähte (Verbindungsleiter) wie gezeigt FR () pullovers comme montré

8 Terminal Block Connections - 2VDC Oil Version 2VDC Ground / Tierra / Erde / La terre 0 Led / Conducido / Mené 1 2VDC (-) 2 (Do not use) / (no el uso) / (nicht verwenden) / (pas l'utilisation) 2VDC (+) 5 Led / Conducido / Mené 6 Pressure switch / Interruptor de presión / Druckschalter / Mano-contact Level switch/ Interruptor de nivel/ Füllstandschalter / Commutateur de niveau Momentary "on" switch/ Interruptor momentáneo de "on" 11 Momentschalter AN / Commutateur momentané de "on" 12 Orange/ Anaranjado M (Customer option)/ (Opción del cliente)/ (Wahl des Kunden)/ (Option de client) 1 1 ENG () Jumpers as shown ESP () puentes según lo demostrado DE () Überbrückungsdrähte (Verbindungsleiter) wie gezeigt FR () pullovers comme montré Grease Version 2VDC Ground/ Tierra/ Erde/ La terre 0 Led/ Conducido/ Mené 1 2VDC (-) 2 (Do not use)/ (no el uso)/ (nicht verwenden)/ (pas l'utilisation) 2VDC (+) 5 Orange/ Anaranjado M Led/ Conducido/ Mené 6 Pressure switch Interruptor de presión/ Druckschalter/ Mano-contact ENG Level switch (N.O) ESP Interruptor de nivel (N.O) DE Füllstandschalter (N.O) FR Commutateur de niveau (N.O)...0VDC (+) Output (+) 200mA...0VDC (-) 11 Brown/ Marrón/ Braun/ Brun Blue/ Azul/ Blau/ Bleu L+ L- Momentary "on" switch/ Interruptor momentáneo de "on" 12 Momentschalter AN / Commutateur momentané de "on" 1 (Customer option)/ (Opción del cliente)/ (Wahl des Kunden)/ (Option de client) 1 15 ENG () Jumpers as shown ESP () puentes según lo demostrado DE () Überbrückungsdrähte (Verbindungsleiter) wie gezeigt FR () pullovers comme montré

9 Installation and Commissioning Install the SureFire SLR Lubricator in the horizontal position ONLY. Attach the lubricator in the desired location and to the desired equipment by means of an appropriately sized bolt through each of the (2) mounting holes in the top plate. For the 1. and 2. liter models, use (2) M6 bolts. For the 6.0 liter models, use (2) M bolts. For the 12.0 liter models, support the reservoir from the bottom. Reservoir size Hortizontal distance between mounting bolts Use bolt 1. 15MM +5/ -0 M MM +5/-0, 2MM +5/-0 M MM +5/-0 M 12.0 The lubricator should be installed in a location that is easy to access, for purposes of viewing the front panels, for ease of reservoir-filling, for ease of service and for ease of attachment to the distribution network plumbing. Remember the SureFire SLR allows attachment of distribution plumbing to either (or both) sides of the top plate. If only one side is used, be sure to plug the unused outlet with a G1/ BSPP plug (one such plug is included with each lubricator). Also, the reservoir on the 1.L, 2.L and 6.0L models can be easily removed by loosening the latches located on ether side of the lubricator. However, to successfully do this, be sure to leave enough clearance underneath the lubricator to allow for the reservoir to be dropped down appropriately. Right view G 1/ BSPP (Min. 6mm O.D. main distribution line tubing recommended) Reservoir latch Two liquid tight fittings are supplied with the lubricator. Use the liquid tight fittings to secure the electrical wiring for the lubricator and to prevent ingress of fluids or dirt into the motor compartment. Typically one of the fittings is used to bring power into the motor compartment and the other fitting is used to bring signal into or out of the motor compartment. All electrical connections are to be made by a qualified technician and all local electrical codes are to be followed. When electrical connections are being made, do so before the power leads are connected and before the power is supplied. Consult the wiring diagram (located under the motor cover) for the correct wiring for your SureFire SLR lubricator. The installation should include a means of disconnecting the power supply for servicing. Such means shall allow for switching off the power during normal operation and/or in an emergency. Also, a residual current device is required to automatically disconnect the power supply in the event of a failure in basic insulation. Be sure that all plumbing distribution lines are clean, are not kinked and are free from any chips or any other impurities. Fill the reservoir through the fill cap and/or fill cap strainer with clean lubricant specified by the Original Equipment Manufacturer and that meets all of the lubricant specifications listed below. Lubricant viscosity Oil, cp Fluid grease, NLGI 000 to 00, ,000 cp Do not overfill the reservoir. Never fill past the MAX level as noted on the reservoir. Overfilling could cause damage to the electrical components located under the motor cover. Pump priming Filling the reservoir and turning on the lubricator is usually enough to prime the pump. However, in the case of a very thick lubricant, sometimes it s necessary to assist priming the pump. Upon initial startup, if no lubricant is being delivered to the pump outlet, make sure the pump is primed. Avoid all kinds of impurities as dirt particles are the most common cause of gear pump failure. If you wish to determine whether the lubricant you plan on using is approved for use with Bijur Lubricating Systems, you can consult the Customer Service Department. To prime the distribution network, plumb the entire system (mainline tubing, manifolds, junctions, air/oil blocks, resistance fittings, resistance fitting outlet tubing to bearing points, etc.). Then, remove a plug or resistance fitting at the point furthest away from the pump. Now, run the pump until bubble-free lubricant flows from this point. Replace the plug or last resistance fitting. All tubing, flexible hoses and fittings must be compatible with the lubricant, operating pressure and surrounding environment. In general, try to install the lubricator in the lowest position (vertically) with relation to the rest of the distribution network and do not allow the tubing to rise and fall when avoiding obstacles. This is in case air enters the distribution lines, the bubbles will tend to rise towards the end of the distribution lines and not get caught anywhere along the way.

10 Maintenance and Service The SureFire SLR lubricator does not require much maintenance. After initial set-up, the lubricator requires only the following maintenance: a) When filling the reservoir with oil, the lubricant must be poured through the oil-filler screen b) The oil-filler screen must be inspected after every or 5 fillings and cleaned if necessary c) If filling with a thin grease, due to the fact that SureFire SLR thin grease models omit the filter screens, be sure the grease is fresh, clean, and is not higher than 0,000 cp viscosity. d) Do not use aggressive cleaners to clean the lubricator. Use only mild cleaners or degreasers to clean the lubricator. In the event of having to replace a pressure gauge, do not remove the adapter from the top plate. Prevent the adapter from rotating with one wrench as you remove the old gauge and install the new gauge with a second wrench. Appropriate pipe thread sealant applied to the male thread of the new gauge is recommended. Troubleshooting Pre-mature wear of the gear pump and the other moving parts is usually caused by dirty or contaminated lubricant. Failure of the SLR lubricator to deliver lubricant can be caused by an incorrect commissioning sequence, resulting in either air or dirt being trapped in the distribution network. A permanently lit (red) LED, present on controller versions, is caused either by the lubricant level in the reservoir being too low, or the system not being able to build enough pressure to trigger the pressure switch, or both. In either case, the red light (fault) can be cleared by filling the reservoir and running the next pressure up/pressure relief cycle successfully. This is usually done by pressing the manual lube button. If you have any questions and need technical assistance, our Customer Service number is: Hydraulic Diagram ON/OFF Timer (optional) The ON/OFF Timer that came with your SureFire SLR Lubricator automatically controls the lubricator to be ON for the time you set and OFF for the time you set. Making the actual settings is covered below. The Timer is a very simple device and as long as power is continuously supplied, it continually cycles the motor of the lubricator ON and OFF based on the time settings you choose. Wiring The wiring diagram is shown on the next page. The Timer is wired to the lubricator motor at the factory. For the oil version, ignore positions -, and use all other positions for other lubricator functions as necessary. For the grease version, ignore positions -, and use all other positions for other lubricator functions as necessary. Also, always be sure to connect your power to terminals 1 and 2 on the Terminal Block as shown, being careful to keep in place any jumpers that were already installed at the factory. If you have a 115VAC or 20VAC model, the motor Duty Cycle is: S 20%, which means the maximum continuous ON time for any cycle is minutes, and if the motor continuous ON time is X, the required minimum OFF time for that same cycle is 5X. If you have a 2VDC model, there are no such maximum ON or minimum OFF time requirements. Time settings Making the ON and OFF settings on the Timer is very simple. The top two dials on the front face control the ON time (0.1 seconds to 0 hours), and the bottom two dials control the OFF time (0.1 seconds to 0 hours). For each pair of dials, the beige colored dial sets the time range for the setting, and the blue colored dial actually makes the setting. For example, if you desired your ON time to be seconds and your OFF time to be 5 minutes, you would set the upper beige dial to be 1- (seconds) and the upper blue dial to be, then you would set the lower beige dial to be 1- (minutes) and the lower blue dial to be 5. It s that simple. The Timer is working whenever power is supplied to it. If the power is interrupted, the Timer completely stops. Once the power is restored, the Timer begins again with whatever it s current ON time setting is. Also, to make lubricator adjustments easy, changes to the ON and OFF time settings can be made while the timer is running, and take effect at the beginning of the very next timed cycle. Please be aware of the motor duty cycle restrictions as previously noted. Bijur recommends that the lubricator be tested after making any time settings. This is to make sure the settings are correct before the pump is left to run in an unattended fashion.

11 Timer - Wiring Diagram Oil Version 115VAC (+) 20VAC (+) 2VDC (+) Ground / Tierra / Erde / La terre 0 115VAC (-) 20VAC (-) 2VDC (-) Pressure switch / Interruptor de presión / Druckschalter / Mano-contact Level switch/ Interruptor llano / Füllstandschalter / Commutateur de niveau 1 2 A1 15 Y1 5 6 Motor Wired at M Factory Momentary "on" switch/ Interruptor momentáneo de "on" Momentschalter AN / Commutateur momentané de "on" (Customer option)/ (Opción del cliente) (Wahl des Kunden)/ (Option de client) 1 16 A2 ENG (1) Jumper as shown ESP (1) puente según lo demostrado DE (1) Überbrückungsdrähte (Verbindungsleiter) wie gezeigt FR (1) pullover comme montré LED Grease Version 115VAC (+) 20VAC (+) 2VDC (+) ENG Level switch (N.O) ESP Interruptor llano (N.O) DE Füllstandschalter (N.O) FR Commutateur de niveau (N.O) Ground/ Tierra/ Erde/ La terre 0 115VAC (-) 20VAC (-) 2VDC (-) Pressure switch/ Interruptor de presión/ Druckschalter/ Mano-contact...0VDC (+) Output (+) 200mA...0VDC (-) Brown/ Marrón/ Braun/ Brun Blue/ Azul/ Blau/ Bleu A1 15 Y1 Motor Wired at Factory Momentary "on" switch/ Interruptor momentáneo de "on" Momentschalter AN / Commutateur momentané de "on" (Customer option)/ (Opción del cliente) (Wahl des Kunden)/ (Option de client) A2 ENG (1) Jumper as shown ESP (1) puente según lo demostrado DE (1) Überbrückungsdrähte (Verbindungsleiter) wie gezeigt FR (1) pullover comme montré LED 11

12 Spare Parts SureFire SLR MODEL NUMBER SF2AxxB SF2AxxC SF2AxxD SFAxxB SFAxxC SFAxxD SF6AxxB SF6AxxC SF6AxxD SF12AxxB SF12AxxC SF12AxxD PART DESCRIPTION PART # PART # PART # PART # Reservoir Reservoir Assembly Reservoir O-Ring Reservoir Gasket Reservoir Clasp 5 6 Bolts Reservoir Clasp Plate Reservoir Clasp Plate Screws Washers Reservoir Inlet Strainer Assembly (w/screws) 5150 Automotive Quick Connector Assembly - for grease applications (with O-Ring) 5151 Automotive Quick Connector Assembly - for oil applications (with O-Ring) 5152 Motor Cover Motor Cover O-Ring 1 2 Motor Cover Screw Level Switch (std. for oil) Level Switch Stem 2 position Level Switch for oil Level Switch for grease 20 Pressure Gauge 2522 Pressure Switch (optional) 255 (normally open) closes at 20psi ± 5psi ON/OFF TIMER (optional) 50 Motor (2 VDC) 262 Motor (115/20 VAC) Motor Fan How to Order 2 1. Liter (Terlu plastic) 2. Liter (Terlu plastic) Liter (Terlu plastic) Liter (Painted steel) A Restrictive/SLR N Standard oil version B Standard grease version (grease level switch, no fill screen) A Quick connect grease version (grease level switch and uick connect st le reservoir fill fitting for grease/no fill screen) C Quick connect oil version ( uick connect st le reservoir fill fitting for oil/no fill screen D Standard oil version (2 position oil level switch) (if controller t pe C is selected) A M12 B 2 VDC, 2. amps C 115 VAC, 50/60 H, 2.2 amps D 20 VAC, 50/60 H,.5 amps A Terminal block B N/ FF timer (not available on 1. liter models) C Programmable controller/monitor Example Standard versions include: float type reservoir low level switch, standard reservoir fill-cap screen, quick dump valve for PDIs, 50 psi pressure relief valve. SF 2 A N A D *Controller type A & B are CE approved. SureFire SLR lubricator, 1. Liter Reservoir, for an SLR distribution network, no options for oil, Terminal Block Version (no timer, no controller), 20VAC incoming power. 12

13 Notes

14

SUREFIRE PDI OPERATORS MANUAL. Single Phase Models (24VDC, 115VAC and 230VAC)

SUREFIRE PDI OPERATORS MANUAL. Single Phase Models (24VDC, 115VAC and 230VAC) SUREFIRE PDI OPERATORS MANUAL Single Phase Models (2VDC, 115VAC and 20VAC) Index General................................................................ 2 Application............................................................

More information

surefire PDI OPERATORS MANUAL Three Phase Models (230/480 VAC) 35027E R

surefire PDI OPERATORS MANUAL Three Phase Models (230/480 VAC) 35027E R surefire PDI OPERATORS MANUAL Three Phase Models (230/480 VAC) Index General...2 Application......................................................... 2 Safety..............................................................

More information

SUREFIRE SLR OPERATORS MANUAL Three Phase Models (230/480 VAC) 35140E r

SUREFIRE SLR OPERATORS MANUAL Three Phase Models (230/480 VAC) 35140E r SUREFIRE SLR OPERATORS MANUAL Three Phase Models (230/480 VAC) Index General...2 Application...2 Safety...2 Precautions and symbols...2 Design and Construction...2 Principle of Operation...3 Technical

More information

Operators Manual SUREFIRE II Single Phase PDI - SLR (24VDC, 115VAC & 230VAC) r#3

Operators Manual SUREFIRE II Single Phase PDI - SLR (24VDC, 115VAC & 230VAC) r#3 Operators Manual SUREFIRE II Single Phase PDI - SLR (24VDC, 115VAC & 230VAC) 36412 r#3 Contents Precautions & Symbols...2 Manufacturer s Statement...2 General...2 Features...2 Operation...3-4 Technical

More information

SureFire II Lubricator

SureFire II Lubricator SureFire II Lubricator Automatic, Oil & Fluid Grease, Single Phase General The SureFire II Lubricator is an automatic, robust and durable pump. Its compact size is designed to fit your space requirements

More information

SureFire II Lubricator

SureFire II Lubricator SureFire II Lubricator Automatic, Oil & Fluid Grease, Three Phase General The SureFire II Lubricator is an automatic, robust and durable pump. Its compact size is designed to fit your space requirements

More information

Operators Manual SUREFIRE II Single Phase PDI - SLR (24VDC, 115VAC & 230VAC) r#2

Operators Manual SUREFIRE II Single Phase PDI - SLR (24VDC, 115VAC & 230VAC) r#2 Operators Manual SUREFIRE II Single Phase PDI - SLR (24VD, 115VA & 230VA) 36412 r#2 ontents Precautions & Symbols...2 Manufacturer s Statement...2 General...2 Features...2 Operation...3-4 Technical Data...5

More information

MOTOR. The electric motor. DC - direct current voltage.

MOTOR. The electric motor. DC - direct current voltage. TMD-5 Lubricator Automatic Cyclic Before installing or operating this lubricator, please read this manual carefully. Failure to follow instructions can result in damage to the product and/or serious bodily

More information

M OTO R. The electric motor. DC - direct current voltage.

M OTO R. The electric motor. DC - direct current voltage. TMD-5 Lubricator Automatic Cyclic Before installing or operating this lubricator, please read this manual carefully. Failure to follow instructions can result in damage to the product and/or serious bodily

More information

DESCRIPTION OPERATION. Product descripption SureFire Electrical Pump

DESCRIPTION OPERATION. Product descripption SureFire Electrical Pump Product descripption SureFire Electrical Pump DESCRIPTION The SureFire centralised lubrication system is robust and durable, capable of handling oil and fluid greases. Available in four reservoir capacities

More information

Operators Manual TTN LUBRICATOR Series Progressive r#9

Operators Manual TTN LUBRICATOR Series Progressive r#9 Operators Manual TTN LUBRICATOR Series Progressive 5580 r#9 Contents Precautions & Symbols... Manufacturer s Statement... General... Application... TTN Lubricator at a Glance... Technical Data...4 ISO

More information

MultiPort Lubricator. Electric motor-driven, Grease and Oil. General. Technical Data. Motor R3 09/09

MultiPort Lubricator. Electric motor-driven, Grease and Oil. General. Technical Data. Motor R3 09/09 MultiPort Lubricator Electric motor-driven, Grease and Oil General The MultiPort Lubricator is a rugged, motor-driven, electric lubricator, equipped with fixed output pumping elements to discharge grease

More information

Fill cap with inlet strainer (40 mesh) Automatic approved quick connect inlet (no strainer)

Fill cap with inlet strainer (40 mesh) Automatic approved quick connect inlet (no strainer) GPO ubricator Motor-driven gear pump, Oil General The GPO ubricator is a motor-driven gear pump that is designed for use with single line centralized lubricating systems utilizing progressive distributors

More information

400 psi (28 bar) PDI & INJ. 100 psi (7 bar) PDI & INJ

400 psi (28 bar) PDI & INJ. 100 psi (7 bar) PDI & INJ Airmatic Lubricator Pneumatic Operation, Oil General The Airmatic lubricator is a simple economical unit with a broad range of output. It is designed to be operated with shop air. The stroke setting is

More information

Model CHASSIS LUBE ELECTRIC GREASE PUMP Series "C"

Model CHASSIS LUBE ELECTRIC GREASE PUMP Series C Model 94222 CHASSIS LUBE ELECTRIC GREASE PUMP Series "C" Indicates change MAY - 2004 FORM 403466 Section - Q3 Page - 12B 7.75" (197 mm) 12.6" (321 mm) 0.35" (9 mm) Mounting Holes 4.85" (123 mm) 8.85" (225

More information

NECO Pumping Systems

NECO Pumping Systems INSTALLATION OPERATION & MAINTENANCE INSTRUCTIONS For Your NECO Pumping Systems Fuel Oil Transfer System THIS COMPLETELY ASSEMBLED, TESTED, PACKAGED SYSTEM IS OF THE HIGHEST QUALITY AND DESIGN. TO OBTAIN

More information

Product manual Oil Streak Sensor INTRODUCTION CONSTRUCTION. Master Sensor

Product manual Oil Streak Sensor INTRODUCTION CONSTRUCTION. Master Sensor Product manual Oil Streak Sensor INTRODUCTION Oil streak sensors are designed to detect traces of oil travelling through air tubes, down to flows as low as 5mm 3 /min. The product utilizes a master and

More information

Airmatic Lubricator. Pneumatic Operation, Oil. General. Application. Operation. Technical Data

Airmatic Lubricator. Pneumatic Operation, Oil. General. Application. Operation. Technical Data Airmatic Lubricator Pneumatic Operation, Oil General The Airmatic lubricator is a simple economical unit with a broad range of output. It is designed to be operated with shop air. The stroke setting is

More information

Versa II SLR Lubricator

Versa II SLR Lubricator Versa II SLR Lubricator With Controller General The Versa II SLR Lubricator is an automatic, robust and durable pump that can handle oil. Its compact size is designed to fit your space requirements and

More information

Models CHASSIS LUBE ELECTRIC GREASE PUMP Series "C" - 13C MAY FORM Page. Section - Q3

Models CHASSIS LUBE ELECTRIC GREASE PUMP Series C - 13C MAY FORM Page. Section - Q3 Models 94422 CHASSIS LUBE ELECTRIC GREASE PUMP Series "C" MAY - 2004 FORM 403467 Section - Q3 Page - 13C 9.00" (229 mm) 13.75" (350 mm) 0.35" (9mm) Mounting Holes 4.76" (121 mm) 9.84" (250 mm) Do not use

More information

Models CHASSIS LUBE ELECTRIC GREASE PUMP Series "C" - Q3. MAY FORM Section

Models CHASSIS LUBE ELECTRIC GREASE PUMP Series C - Q3. MAY FORM Section Models 94822 CHASSIS LUBE ELECTRIC GREASE PUMP Series "C" - Q3 MAY - 2004 FORM 403468 Section Page - 14B 13.00" (330 mm) 17.72" (450 mm).35" (9 mm) Mounting Holes 4.72" (120 mm) 9.84" (250 mm) Figure 1

More information

SureFire SLR Lubricator

SureFire SLR Lubricator Sureire SR ubricator utomatic, Oil eneral he Sureire SR automatic lubricator is a robust and durable pump that can handle oil and soft greases. Its compact size is designed to fit your space requirements

More information

MultiPort Lubricator. Electric motor-driven, Grease and Oil. General. Technical Data. Motor R6 08/17

MultiPort Lubricator. Electric motor-driven, Grease and Oil. General. Technical Data. Motor R6 08/17 MultiPort Lubricator Electric motor-driven, Grease and Oil General The MultiPort Lubricator is a rugged, motor-driven, electric lubricator, equipped with fixed or adjustable output pumping elements to

More information

SUREFIRE SLR. Centralized Lubricating System. + SureFire SLR Automatic Lubricator + Resistance Fittings + Distribution Components + Accessories

SUREFIRE SLR. Centralized Lubricating System. + SureFire SLR Automatic Lubricator + Resistance Fittings + Distribution Components + Accessories SUREFIRE SLR Centralized Lubricating System + SureFire SLR Automatic Lubricator + Resistance Fittings + Distribution Components + Accessories Contents Protect Expensive Machinery... 3 SureFire SLR Lubricator...

More information

Farval. Dualine Installation System Start-Up. Bulletin DL300 BIJUR DELIMON INTERNATIONAL

Farval. Dualine Installation System Start-Up. Bulletin DL300 BIJUR DELIMON INTERNATIONAL Farval Dualine Installation System Start-Up Bulletin DL300 BIJUR DELIMON INTERNATIONAL 2685 Airport Road Kinston, NC 28504 Tel. 800-227-1063 Fax: 252-527-9232 website: www.bijurdelimon.com DC1-1 SECTION

More information

MultiPort Lubricator. Electric motor-driven, Grease and Oil. General. Technical Data. Motor R8 08/18

MultiPort Lubricator. Electric motor-driven, Grease and Oil. General. Technical Data. Motor R8 08/18 MultiPort Lubricator Electric motor-driven, Grease and Oil General The MultiPort Lubricator is a rugged, motor-driven, electric lubricator, equipped with fixed or adjustable output pumping elements to

More information

Oil Streak Air-Oil Generating Unit

Oil Streak Air-Oil Generating Unit Oil Streak Air-Oil Generating Unit GENERAL The Air-Oil Generating system delivers high efficiency lubrication for high-speed spindles and other applications requiring accurate oil deliveries, in combination

More information

Use Type C control units. Viscosity range is 100 to 10,000 SSU at operating temperature. See Bijur Engineering Manual for system limitations.

Use Type C control units. Viscosity range is 100 to 10,000 SSU at operating temperature. See Bijur Engineering Manual for system limitations. V5W Lubricator Automatic Continuous Operation The V5W Lubricator consists of a motor-driven gear pump, with a controlled bypass valve. (constant volume or constant pressure models) The fully automatic

More information

ProFlo FatBoy

ProFlo FatBoy The Standard For Professional Grade Diaphragm Pumps. ProFlo 3300 5500 FatBoy Operational and Installation Guidelines, Repair & Parts Contents 3300 5500 Fatboy Operational and Installation Guidelines...2

More information

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS Model 31801 and 31800 Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS INDUSTRIAL DIAPHRAGM PUMPS FEATURES Run Dry Ability Self-Priming Thermal Overload Protected Motor Easy Installation Low Amp Draw Compact

More information

To ensure proper installation, digital pictures with contact information to before startup.

To ensure proper installation,  digital pictures with contact information to before startup. Check List for Optimal Filter Performance [ ] There should be no back-pressure on the flush line. A 1 valve should have a 2 waste line, and 2 valve should have a 3 waste line. Do not use rubber hosing

More information

4.2 Component Identification

4.2 Component Identification Digital Control Panels Deep Sea Electronics 5220 4.1 General 4.2 Component Identification 4.3 The YML5220 Controller 4.4 Description of Controls 4.5 Navigation 4.5.1 General Navigation 4.5.2 The Event

More information

SHURFLO HIGH FLOW SYSTEM II 10.0 GPM MARINE FRESH WATER SYSTEM PRODUCT TECHNICAL DATA SHEET

SHURFLO HIGH FLOW SYSTEM II 10.0 GPM MARINE FRESH WATER SYSTEM PRODUCT TECHNICAL DATA SHEET SHURFLO HIGH FLOW SYSTEM II 10.0 GPM MARINE FRESH WATER SYSTEM PRODUCT TECHNICAL DATA SHEET OEM: AFTERMARKET: 4558-153-E75 4558-153-E75 APPLICATION: Multi-fixture Marine fresh water system installation.

More information

THE REVOLUTIONARY P653S ELECTRIC CENTRO-MATIC PUMP

THE REVOLUTIONARY P653S ELECTRIC CENTRO-MATIC PUMP Lincoln The Industry Leader Since 1910 The Heart of a Centro-Matic Automated Lubrication System The P653S is the central pump station that automatically delivers lubricant through a single supply line

More information

FLEX VANE IMPELLER MODEL 3000-XXX Replacement Parts Kit Instructions

FLEX VANE IMPELLER MODEL 3000-XXX Replacement Parts Kit Instructions FLEX VANE IMPELLER MODEL 3000-XXX Replacement Parts Kit Instructions WARNING:Do not pump flammable liquids! Model 3000 pumps (Buna impeller) are suitable for non-potable water, automotive oil, automatic

More information

Medium and high pressure pumps

Medium and high pressure pumps Screw pumps Medium and high pressure pumps Installation and Start-up Instruction This instruction is valid for all standard high pressure pumps: E4, D4 and D6 Contents Page Pump identification 2 Installation

More information

Installation Instructions

Installation Instructions ``````````````````````` Wolf cdn een n en Installation Instructions SDS SPRINGLESS DOOR SYSTEM 230VAC 1PH Date: 23.03.2016 Version: II-SDS-001-01 1 1 1. SAFETY DIRECTIONS Basic Directions This system has

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Universal Air Series!! NOTE!! Covers the following model: 6000 Series 85-0100B-AZ Rev 0 5/07 To ensure that the system is installed properly, provide your electrician with these

More information

MODELS 9917, , 9946P and 9989 High Pressure Lubrigun Series A

MODELS 9917, , 9946P and 9989 High Pressure Lubrigun Series A MODELS 9917, 9917-57, 9946P and 9989 Series A NOTE: Pails and Drums shown for illustration only. not included with models. MAR - 2007 Section - A5 Page - 84 DESCRIPTION Models 9917, 9917-57, 9946P, and

More information

3 FT CORD UL/NEC Models , , , FT CORD w/gfci UL Models , , ,

3 FT CORD UL/NEC Models , , , FT CORD w/gfci UL Models , , , POWERLINE XP I Swimming Pool Pump (Light Oak color model) 3 FT CORD UL/NEC Models 0-1295-206, 0-1296-206, 0-1297-206, 0-1298-206 25 FT CORD w/gfci UL Models 0-1295-200, 0-1296-200, 0-1297-200, 0-1298-200

More information

A system of lubricant dispensing devices (oil or grease) connected by piping to a central pumping unit that is operated automatically or manually.

A system of lubricant dispensing devices (oil or grease) connected by piping to a central pumping unit that is operated automatically or manually. Air/Oil Systems: A lubrication system in which small measured quantities of oil are introduced into an air/oil mixing device which is connected to a lube line that terminates at a bearing, or other lubrication

More information

POND PUMP Model Nos:SPP3 & SPP6 0200

POND PUMP Model Nos:SPP3 & SPP6 0200 OPERATING & MAINTENANCE INSTRUCTIONS POND PUMP Model Nos:SPP3 & SPP6 0200 Thank you for purchasing this CLARKE Water Pump, which is particularly suitable for the filtration of small to medium size swimming

More information

AIR/HYDRAULIC INJECTION GUN MODEL INSTRUCTIONS

AIR/HYDRAULIC INJECTION GUN MODEL INSTRUCTIONS I. OPERATION & DESCRIPTION The Air / Hydraulic Injection Gun is a high-pressure tool that should be used with caution and according to these instructions. IMPORTANT: The Gun is 0,000 psi rated. Do not

More information

Click Here for Printable PDF File. CHAPTER 3 - BASIC INFORMATION for PERFORMING HYDRAULIC SYSTEM MAINTENANCE

Click Here for Printable PDF File. CHAPTER 3 - BASIC INFORMATION for PERFORMING HYDRAULIC SYSTEM MAINTENANCE HWH Online Technical School Lesson 1: Introduction to Hydraulics Chapter 3 - "BASIC INFORMATION for PERFORMING HYDRAULIC SYSTEM MAINTENANCE" (Filename: ML57000-012-CH3.DOC Revised: 22APR16) Click Here

More information

Tekleen LPF USERS AUTOMATIC FILTERS, INC. MANUAL

Tekleen LPF USERS AUTOMATIC FILTERS, INC. MANUAL AUTOMATIC FILTERS, INC. 2672 S. LA CIENEGA BLVD. LOS ANGELES, CA 90034 310 839 2828 800 336 1942 FAX 310 839 6878 www.tekleen.com info@tekleen.com Tekleen LPF USERS MANUAL Table of Contents SECTION I INTRODUCTION

More information

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited. SERVICE MANUAL ELECTRIC BRAISING PANS (30 & 40 GALLON) VE30 VE40 ML-126849 ML-126850 VE40 SHOWN - NOTICE - This Manual is prepared for the use of trained Vulcan Service Technicians and should not be used

More information

MODEL NUMBER: MEDIUM DUTY ONBOARD AIR SYSTEM

MODEL NUMBER: MEDIUM DUTY ONBOARD AIR SYSTEM MODEL NUMBER: 10003 MEDIUM DUTY ONBOARD AIR SYSTEM IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using

More information

LEAD ACID BATTERY CHARGER

LEAD ACID BATTERY CHARGER LEAD ACID BATTERY CHARGER MODEL NO: LA4 & LA6 OPERATION & MAINTENANCE INSTRUCTIONS LS1214 INTRODUCTION Thank you for purchasing this CLARKE Battery Charger. Please read this manual thoroughly, before attempting

More information

XCITE Owner s Manual. Reso-not TM Damping System XCITE 1502C HYDRAULIC POWER SUPPLY

XCITE Owner s Manual. Reso-not TM Damping System XCITE 1502C HYDRAULIC POWER SUPPLY Reso-not TM Damping System XCITE Owner s Manual 1502C HYDRAULIC POWER SUPPLY Xcite Systems Corporation 675 Cincinnati RDS Batavia - 1 Pike Cincinnati, Ohio 45245 Tel: (239) 980-9093 Fax: (239) 985-0074

More information

To ensure proper installation, digital pictures with contact information to before startup.

To ensure proper installation,  digital pictures with contact information to before startup. Check List for Optimal Filter Performance? There should be no back-pressure on the flush line. A 1 valve should have a 2 waste line, and 2 valve should have a 3 waste line. Do not use rubber hosing or

More information

3 FT CORD Models , , , FT CORD W/GFCI Models , , ,

3 FT CORD Models , , , FT CORD W/GFCI Models , , , POWERLINE XP II Swimming Pool Pump (Light Oak color model) With Automatic Timer 3 FT CORD Models 0-1395-226, 0-1396-226, 0-1397-226, 0-1398-226 25 FT CORD W/GFCI Models 0-1395-220, 0-1396-220, 0-1397-220,

More information

DCE 100 Series Dust Filter

DCE 100 Series Dust Filter Installation, Operation and Maintenance Manual DCE 100 Series Dust Filter Publication 2638B (GB) 0702 1419-8000A Donaldson Torit DCE reserve the right to alter design without notice. Freedom from patent

More information

M Installation Guide. PRECISION Manifold Series. Introduction. A. Assemble Manifold Components

M Installation Guide. PRECISION Manifold Series. Introduction. A. Assemble Manifold Components Page 1 Introduction The M-8200 Precision Manifolds are designed for use in Hydronic radiant panel heating and cooling applications. They are available in various sizes, configurations, and options with

More information

Oil-free piston compressors KK and piston vacuum pumps KV

Oil-free piston compressors KK and piston vacuum pumps KV Oil-free piston compressors KK and piston vacuum pumps KV Installation and Operating Instructions 0678106030L02 1707V003 Contents Important information 1 About this document 2 1.1 Warnings and symbols

More information

Operating Instructions & Parts Manual

Operating Instructions & Parts Manual Operating Instructions & Parts Manual Grainger Model No. 36NE14 Bucher Hydraulics Model No. M-4509-0217 Please read the instructions carefully and always operate this equipment in a safe manner. Unit Description:

More information

Type 6213 EV, 6281 EV

Type 6213 EV, 6281 EV Type 6213 EV, 6281 EV 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 OPERATING INSTRUCTIONS The operating instructions

More information

WALKIE HIGH LIFT HYDRAULIC SYSTEM

WALKIE HIGH LIFT HYDRAULIC SYSTEM WALKIE HIGH LIFT HYDRAULIC SYSTEM W30-40ZA [B453]; W20-30ZR [B455]; W25-30-40ZC [B454] PART NO. 1524251 2000 SRM 1025 SAFETY PRECAUTIONS MAINTENANCE AND REPAIR When lifting parts or assemblies, make sure

More information

50:1 Grease Pump Kits

50:1 Grease Pump Kits TM INS680A Published: 6/0/00 Revised 7/8/06 50: Grease Pump Kits Models L680A Read the following precautions and instructions before you begin assembly or using. Failure to comply with these instructions

More information

Operating and Installation Instructions

Operating and Installation Instructions Model Number 40401-c (-sp) Electronic Fuel Pump Operating and Installation Instructions This Product is Patent Pending. Application available upon request CAUTION! This product is to be installed only

More information

INSTRUCTION MANUAL. I/P Converter DSG BXXY3Z DSG BXXY4Z

INSTRUCTION MANUAL. I/P Converter DSG BXXY3Z DSG BXXY4Z INSTRUCTION MANUAL I/P Converter DSG BXXY3Z DSG BXXY4Z Revision 2.0 3.626 016136 en Page 1/15 Should you have any questions concerning the I/P converter, please contact the Service Department of the Product

More information

Operating instructions Form no safety definitions

Operating instructions Form no safety definitions Operating instructions Form no. 1000437 safety definitions safety symbols are used to identify any action or lack of action that can cause personal injury. Your reading and understanding of these safety

More information

SKF Electro-pneumatic Barrel Pump EPB-Pump-ECO (Original operating and maintenance instructions according to EU Directive 2006/42/EC)

SKF Electro-pneumatic Barrel Pump EPB-Pump-ECO (Original operating and maintenance instructions according to EU Directive 2006/42/EC) SKF Electro-pneumatic Barrel Pump EPB-Pump-ECO (Original operating and maintenance instructions according to EU Directive 2006/42/EC) TABLE OF CONTENTS 1 EC Declaration of incorporation...1 2 General description...2

More information

ELECTRIC HYDRAULIC GEAR PUMP

ELECTRIC HYDRAULIC GEAR PUMP ELECTRIC HYDRAULIC GEAR PUMP 46169 ASSEMBLY AND OPERATING INSTRUCTIONS 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our Web site at http://www.harborfreight.com Copyright 2001 by Harbor Freight Tools.

More information

Type 5411, Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type 5411, Operating Instructions. Bedienungsanleitung Manuel d utilisation Type 5411, 5413 3/2 or 4/2 way solenoid valve 3/2 oder 4/2-Wege-Magnetventil Électrovanne 3/2 ou 4/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 THE OPERATING INSTRUCTIONS The

More information

Troubleshooting of the LubeTech Grease System

Troubleshooting of the LubeTech Grease System Troubleshooting of the LubeTech Grease System February 2009 The LubeTech grease system is designed to be a preventative maintenance system that will extend the life of your bearings that are connected

More information

DIESEL Engine Fire Pump Controllers Features

DIESEL Engine Fire Pump Controllers Features 1-1 Printer / Recorder The industrial grade thermal printer is housed in a rugged steel enclosure within the controller. The on/off switch, feed and reset buttons are front accessible. A bi-color status

More information

H.S. MACHINERY RING COMPRESSORS

H.S. MACHINERY RING COMPRESSORS OPERATION & PARTS MANUAL Thank you for purchasing an H.S Machinery Limited Regenerative Blower. This product is manufactured under strict ISO-9001-2000 quality control guidelines to ensure your satisfaction.

More information

USER MANUAL. Copyright 2006, PowerStation, LLC All rights reserved MODEL: PS5000M

USER MANUAL. Copyright 2006, PowerStation, LLC All rights reserved MODEL: PS5000M USER MANUAL Copyright 2006, PowerStation, LLC All rights reserved MODEL: PS5000M CONTENTS Warning Information 1 3 Introduction 4 Features 4 Getting to know your PS5000M 5-6 Operation 7 Charging before

More information

M-8100EP. Installation Guide ENGINEERED PLASTIC MANIFOLD SERIES. Introduction. A. Assemble Manifold Components

M-8100EP. Installation Guide ENGINEERED PLASTIC MANIFOLD SERIES. Introduction. A. Assemble Manifold Components Introduction The Pro Manifolds with Integrated adaptor are designed for use in Hydronic radiant panel heating and cooling applications. They are available in various sizes, configurations, and options

More information

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION VQ400M SERIES PRODUCT HANDBOOK APPLICATION The VQ400M Series class A safety combination valves are used for control and regulation of gaseous fluids in gas power burners, atmospheric gas boilers, melting

More information

WALKIE HYDRAULIC SYSTEMS

WALKIE HYDRAULIC SYSTEMS WALKIE HYDRAULIC SYSTEMS B60Z [A230]; B80Z [A233]; C60Z [A478]; C80Z [A479]; W60Z [A231]; W65Z [A229]; W80Z [A234]; B60Z AC [B230]; B80Z AC [B233]; C60Z AC [B478]; C80Z AC [B479] PART NO. 1500201 1900

More information

Assembly instructions

Assembly instructions Assembly instructions CP-Lube kit RX4,RX8,RX22,RX25,RX29,RX45,RX53 CP-Lube kit RX 4 CP-Lube kit RX 8 CP-Lube kit RX 22 CP-Lube kit RX 25 CP-Lube kit RX 29 CP-Lube kit RX 45 CP-Lube kit RX 53 Valid from

More information

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN SYMBOL LEGEND DANGER THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN WARNING THIS WARNS THAT MATERIALS MAY BE DAMAGED IF APPROPRIATE PRECAUTIONS ARE NOT

More information

Operating Instructions & Parts Manual

Operating Instructions & Parts Manual Operating Instructions & Parts Manual Grainger Part No. 36NE08 Bucher Hydraulics Part No. M-3504-0239 Please read the instructions carefully and always operate this equipment in a safe manner. Unit Description:

More information

OCTOPUS SELECTION & INSTALLATION GUIDE Rev. C CRA SERIES CONTINUOUS RUNNING PUMPSET

OCTOPUS SELECTION & INSTALLATION GUIDE Rev. C CRA SERIES CONTINUOUS RUNNING PUMPSET A. GENERAL DESCRIPTION: OCTOPUS SELECTION & INSTALLATION GUIDE Rev. C CRA SERIES CONTINUOUS RUNNING PUMPSET Octopus CRA continuous running pumps are very reliable quiet and efficient devices which will

More information

Installation Manual. Q Series Quadplex Grinder Systems. Contents

Installation Manual. Q Series Quadplex Grinder Systems. Contents Installation Manual 7759000A Q4800 - Series Quadplex Grinder Systems Features: 48 Diameter Fiberglass Tank Available in 84, 96, and 120 heights LSG Single or LSGX 2 Stage 2 HP Grinder Pumps Factory Installed

More information

Battery Power Inverters

Battery Power Inverters Battery Power Inverters Renogy 500W 1000W 2000W Pure Sine Wave Inverter Manual 2775 E. Philadelphia St., Ontario, CA 91761 1-800-330-8678 1 Version 1.4 Important Safety Instructions Please save these instructions.

More information

Air / Hydraulic Pump

Air / Hydraulic Pump Form No. 538016 Parts List & Operating Instructions for: 2510A Original Instructions Air / Hydraulic Pump Maximum Capacity: 690 bar (10,000 psi) Description: The 2510A air/hydraulic pump is designed to

More information

OPERATOR S MANUAL A

OPERATOR S MANUAL A OPERATOR S MANUAL 670144-A INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED: 12-18-15 1/4" DIAPHRAGM PUMP 1:1 RATIO (NON-METALLIC) (REV: A) 67 0144-A READ THIS MANUAL CAREFULLY BEFORE INSTALLING,

More information

MultiPort II Lubricator

MultiPort II Lubricator MultiPort II Lubricator Mobile, PDI, Grease General The MultiPort II Lubricator is an electrically driven multiple outlet lubrication unit designed primarily for use with positive displacement injector(pdi)

More information

SALDET SALES & SERVICE, INC. CLINTON TOWNSHIP, MICHIGAN

SALDET SALES & SERVICE, INC. CLINTON TOWNSHIP, MICHIGAN Form 1254 BRAKETRON Electronic Motor Brake Instructions SALDET SALES & SERVICE, INC. CLINTON TOWNSHIP, MICHIGAN TABLE OF CONTENTS SECTION TITLE PAGE I. Introduction 1 II. Specifications 1 III. Principles

More information

OWNER/OPERATOR MANUAL. Airmotor effective dia. in. 2.5

OWNER/OPERATOR MANUAL. Airmotor effective dia. in. 2.5 MODELS 282050, 282716 & 283513 AIR OPERATED CHASSIS PUMP SERIES A OWNER/OPERATOR MANUAL SPECIFICATIONS Airmotor effective dia. in. 2.5 Airinlet Material outlet 1/4 NPTF 1/4 NPTF Liquid to Air Pressure

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Type 5282 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 OPERATING INSTRUCTIONS The operating instructions contain

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Type 5404 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation Contents 1 Operating instructions...2 2 Intended use...3 3

More information

FL7M-A Series. Aluminum-chip Immunity DC 2-wire Type Cylindrical Proximity Sensors. Specifications. click FEATURES ORDER GUIDE

FL7M-A Series. Aluminum-chip Immunity DC 2-wire Type Cylindrical Proximity Sensors. Specifications. click FEATURES ORDER GUIDE 6 FL7M-A Series FEATURES Workpieces Reliably Sensed Even if Aluminum or Cast Iron Chips Accumulate on the Sensing Head. This DC 2-wire type proximity sensor can be directly connected to programmable controllers

More information

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1 INLINE Flow sensor for hazardous area II G/D - II D - II GD - I M Type SE0 Ex can be combined with... Flow meter with NAMUR or NPN/PNP output signal Mounting, dismounting of electronics by a Quarter-Turn

More information

Instruction Manual. Maximum Operating Pressure 700 bar

Instruction Manual. Maximum Operating Pressure 700 bar Remote Hydraulic Cutter Model HC-120R Maximum Operating Pressure 700 bar ABSOLUTE EQUIPMENT PTY LTD 2/186 Granite Street, GEEBUNG QLD 4034 Australia sales@absoluteequipment.com.au Phone: +61 7 3865 4006

More information

Service Guide: Power Supply Model

Service Guide: Power Supply Model Service Guide: Power Supply Model 153808 The Power Supply, converts, regulates and distributes electric power from the electrical mains supply to components installed on Midmark Dental Chairs. Contents:

More information

Portable Filter Carts Models 5MF and 10MF

Portable Filter Carts Models 5MF and 10MF s Models 5MF and 10MF 161 Applications for Parker Filter Carts Filtering new fluid before putting into service Transferring fluid from drums or storage tanks to system reservoirs Conditioning fluid that

More information

230V DIESEL FUEL TRANSFER PUMP MODEL NO: DFT230

230V DIESEL FUEL TRANSFER PUMP MODEL NO: DFT230 230V DIESEL FUEL TRANSFER PUMP MODEL NO: DFT230 PART NO: 7160050 OPERATION & MAINTENANCE INSTRUCTIONS GC0816 INTRODUCTION Thank you for purchasing this CLARKE Pump. The DFTP230 pump is a self-priming rotary

More information

Maxum II Modular Oven Automatic Purge Control Unit Product Update PU-002

Maxum II Modular Oven Automatic Purge Control Unit Product Update PU-002 Maxum II Modular Oven Automatic Purge Control Unit Product Update PU-002 Revision History Issue Date Reason 001 6/15/2016 Initial Issue 002 11/17/2016 Correct relay labels Copyright Siemens AG 2015 All

More information

CXL2 Injectors & Manifolds

CXL2 Injectors & Manifolds CXL2 Injectors & Manifolds Premium Single Line Grease Systems General Designed for use in single line high pressure automatic grease systems, CXL2 Injectors deliver precise volumes of lubricant at predetermined

More information

DuraMAC LIGHT COMMERCIAL & IRRIGATION WATER PRESSURE BOOSTER SYSTEM INSTALLATION INSTRUCTIONS

DuraMAC LIGHT COMMERCIAL & IRRIGATION WATER PRESSURE BOOSTER SYSTEM INSTALLATION INSTRUCTIONS DuraMAC LIGHT COMMERCIAL & IRRIGATION WATER PRESSURE BOOSTER SYSTEM INSTALLATION INSTRUCTIONS The DuraMAC TM Water Pressure Booster System is the first booster pump of its kind to be designed for virtually

More information

USER S MANUAL. Installation, Operation, & Maintenance

USER S MANUAL. Installation, Operation, & Maintenance 1-800-899-0553 assuredautomation.com SM Series Motorized Ball Valves On/Off & Modulating Electric Actuators USER S MANUAL Installation, Operation, & Maintenance Assured Automation 263 Cox Street, Roselle,

More information

Model &

Model & PumpAgents.com - Click here for Pricing/Ordering Model 31765-0092 & 31765-0094 Dual Sensor Max VSD WATER PRESSURE SYSTEM AUTOMATIC TWO STAGE WATER SYSTEM WITH PUMPGARD STRAINERS IDEAL FOR PLEASURE AND

More information

MultiPort II Lubricator

MultiPort II Lubricator MultiPort II Lubricator Mobile, Progressive, Grease General The MultiPort II Lubricator is an electrically driven multiple outlet lubrication unit designed primarily for use with progressive divider valve

More information

Manifold Isolation Valves

Manifold Isolation Valves 300 N. Opdyke Rd. Introduction The Stainless Manifolds are designed for use in Hydronic radiant panel heating and cooling applications. They are available in various sizes, configurations, and options

More information

Instruction Manual. 08 Series Auto 2 Speed Electric Power Units Model PEM8414 & PEM8424. Maximum Operating Pressure 700 bar

Instruction Manual. 08 Series Auto 2 Speed Electric Power Units Model PEM8414 & PEM8424. Maximum Operating Pressure 700 bar 08 Series Auto 2 Speed Electric Power Units Model PEM8414 & PEM8424 PEM8414 PEM8424 Maximum Operating Pressure 700 bar ABSOLUTE EQUIPMENT PTY LTD 2/186 Granite Street, GEEBUNG QLD 4034 Australia sales@absoluteequipment.com.au

More information

SUBMERSIBLE WATER PUMPS

SUBMERSIBLE WATER PUMPS SUBMERSIBLE WATER PUMPS Model Nos. CS85S - CS85SA CS120S - CS120SA CS185S - CS185SA CS240S - CS240SA CS305S - CS305SA OPERATING & MAINTENANCE INSTRUCTIONS 1000 CONTENTS Warranty conditions... 3 Safety

More information

Agxcel GX12i Chemical Injection System

Agxcel GX12i Chemical Injection System Agxcel GX12i Chemical Injection System Table of Contents System Contents... 3 Specifications... 4 Safety Precautions and Tips... 5 Operations... 6 Installation... 7 Maintenance... 8-9 Troubleshooting...

More information