CONTRACTOR/CM: DISTRIBUTION PANELBOARDS

Size: px
Start display at page:

Download "CONTRACTOR/CM: DISTRIBUTION PANELBOARDS"

Transcription

1 SUBMITTAL TRANSMITTAL OCPS CLAY SPRINGS ES SUBMITTAL NUMBER: SUBMITTAL DETAILS: SUBJECT: CONTRACTOR/CM: DISTRIBUTION PANELBOARDS : WILLIAMS COMPANY : BRAD KUBIN 30 SILVER STAR RD. ORLANDO, FL, 3809 (407) FAX:(407) BUILDING REFERENCE: DATE RECIEVED: DISCIPLINE: PRIORITY STATUS: SPECIFICATION REF: Oct 09, 04 Electrical -STANDARD REVIEWER DUE DATE: 0//04 DATE RETURNED TO CM: 0/0/04 DWG REF. NONE DWG TITLE: RETURNED ITEMS: NO OF ITEMS: ITEM DESCRIPTI Product Literature(s) REVIEW STATUS: REJECTED REVIEWERS: COMMENTS: PRIMARY: TAD RIVENBARK MATERN ENGINEERING PHN: (407) FAX: (407) trivenbark@matern.net SECONDARY: PLEASE SEE A/E COMMENTS KEVIN KING MATERN ENGINEERING PHN: (407) FAX: (407) kking@matern.net REVIEWED Rhodes+Brito Architects, Inc. Rhodes+Brito Architects, Inc. have reviewed and acknowledge this document as reviewed/responded to by Consultant/EOR. This review is only for general conformance with the design concept and the information given in the Contract Documents. By: Rick Dunn Date: 0/0/4 cc: OWNER : CALVIN WOOLFOLK 650 MAGIC WAY, BLDG. 00 ORLANDO, FL, 3809 (407) FAX:(407) R+B FILE: : X6 RHODES + BRITO ARCHITECTS INC. : 605 E. ROBINSON STREET, SUITE 750 : ORLANDO, FL. : 380 : : FAX PAGE OF

2 SHOP DRAWING COMMENTS Date: October 0, 04 Project: OCPS Clay Springs E.S. By: Tad Rivenbark Proj. No: 03-4 Submittal: Distribution Panelboards THE FOLLOWING COMMENTS SHALL BE CONSIDERED AN INTEGRAL PART OF THE SHOP DRAWING AND/OR PRODUCT DATA SUBMITTAL. ACTION CODE KEY A B C D E N No exceptions taken. Make corrections noted. Revise and Resubmit. Submit Specified Item. Rejected. Review not required : Rejected. A preliminary copy of the Power System Study has not been submitted. The gear will not be reviewed without the study. Per Specification A, a summary of the short circuit analysis shall be submitted at the time shop drawings for all new equipment is submitted for approval. Per Specification B, the final selection of all protective devices shall be based on preliminary draft of the coordination study, which shall be submitted with the equipment shop drawings for review. END OF SHOP DRAWING COMMENTS Page of Corporate Office: 30 Candace Drive, Maitland, Florida Phone: Orlando Fort Myers Jacksonville Tampa Registered: FLORIDA * GEORGIA* LOUISIANA * NORTH CAROLINA * SOUTH CAROLINA * TEXAS * TENNESSEE * VIRGINIA

3 SUBMITTAL ASSIGNMENT MEMO OCPS CLAY SPRINGS ES SUBMITTAL NUMBER: SUBMITTAL DETAILS: SUBJECT: REVIEWERS: DISTRIBUTION PANELBOARDS PRIMARY: TAD RIVENBARK MATERN ENGINEERING PHN: (407) FAX: (407) DATE RFI RECIEVED: Oct 09, 04 DISCIPLINE: Electrical PRIORITY STATUS: -STANDARD SPECIFICATION REF: REVIEWER DUE DATE: 0//04 DWG REF. NONE DWG TITLE: SECONDARY: KEVIN KING MATERN ENGINEERING PHN: (407) FAX: (407) kking@matern.net SUBMITTAL CONTENTS: NO OF ITEMS: ITEM DESCRIPTION PRODUCT LITERATURE(S) REVIEW STATUS: REVIEWED FURNISHED AS MARKED REVISE AND RESUBMIT THIS SUBMITTAL IS ISSUED TO YOU FOR YOUR REVIEW. PLEASE RESPOND AND RETURN...WITH THIS COMPLETED SAM TRANSMITTAL...TO MICHELE BUDAY-URDANETA NO LATER THAN: 0//04. PLEASE COMPLETE REVIEW STATUS AT RIGHT RE-SUBMIT WITH ITEMS NOT REVIEWED REJECTED COMMENTS: THIS SUBMITTAL WAS REVIEWED BY : (please print) cc: OWNER : CALVIN WOOLFOLK 650 MAGIC WAY, BLDG. 00 ORLANDO, FL, 3809 CONTR/CM: : WILLIAMS COMPANY : BRAD KUBIN 30 SILVER STAR RD. R+B FILE: : X6

4 430 West Drive Altamonte Springs, Florida 374 EC Phone: (407) //4 CLAY SPRINGS ELEMENTARY SCHOOL TCE JOB #00707 OWNER: Orange County Public Schools Design & Construction Bldg. 00, 650 Magic Way Orlando, FL 3809 GENERAL CONTRACTOR: Williams Company 30 Silver Star Road Orlando, FL 3804 ARCHITECT: Rhodes + Brito Architects 605 E. Robinson Street, Suite 750 Orlando, FL 380 ENGINEER: Matern Professional Engineering, Inc. 30 Candace Drive Maitland, FL 375 SUBCONTRACTOR: Tri-City Electrical Contractors, Inc. 430 West Drive Altamonte Springs, FL 374 Specification Section: Distribution Panelboards Submittal Cover.doc ABC ACCREDITED QUALITY CONTRACTOR EC

5 Clay Springs ES Submittal for Approval Negotiation Number OR85070X4K Volume of Equipment: Distribution Panelboards Date: 8/5/04 03 Eaton Corporation, All Rights Reserved

6 Main Table of Contents.0 Distribution Panelboards. Technical Documents 3 7

7

8 Detail Bill of Material Project Name: General Order No: Item No. Qty Product Panelboards Description 8Circuits, 400A, Series Rated, 480Y/77V 3Ph 4W, Copper Bus, 65k AIC, 400A, HKD 3P Main Breaker[Bottom Fed], Surface Mounted Catalog No Designation Qty 6 Item No. Qty Product Panelboards Qty 6 6 Qty P3D400BB4CH0 HDPC List of Materials 400A, HKD 3P Main Breaker 90A, 3P EHD Branch Breaker 00A, 3P EHD Branch Breaker 0A, P EHD Branch Breaker 60A, 3P EHD Branch Breaker Copper Main Bus, 400 Amps Std. Bolted Cu Ground Bar (Cu Cable Only) Panel Nameplate - Orange with White Letters Type Enclosure: EZB07R EZ Trim, Door in Door, Concealed Hardware: EZT07S Description 4Circuits, 400A, Series Rated, 480Y/77V 3Ph 4W, Copper Bus, 65k AIC, 400A, HKD 3P Main Breaker[Bottom Fed], Surface Mounted Catalog No Designation Item No. Clay Springs ES Product Panelboards P3D400BB3CH0 HDPA List of Materials 400A, HKD 3P Main Breaker 70A, 3P EHD Branch Breaker 40A, 3P FD Branch Breaker 75A, 3P FD Branch Breaker 50A, 3P FD Branch Breaker P EHD Branch Provision Only 0A, P EHD Branch Breaker Copper Main Bus, 400 Amps Std. Bolted Cu Ground Bar (Cu Cable Only) Panel Nameplate - Orange with White Letters Type Enclosure: EZB07R EZ Trim, Door in Door, Concealed Hardware: EZT07S Description 30Circuits, 800A, Fully Rated, 480Y/77V 3Ph 4W, Copper Bus, 65k AIC, 800A, Main Lugs Only[Bottom Fed], Surface Mounted Catalog No Designation Qty 3 6 P4D800LB4CH0 HDPB List of Materials 800A, Main Lugs Only Padlockable Hasp Lockoff Device Padlockable Hasp Lockoff Device Padlockable Hasp Lockoff Device 00A, 3P HFD Branch Breaker Negotiation No: Alternate No: Page of 3 OR85070X4K 0007

9 Detail Bill of Material Project Name: General Order No: Qty 6 9 Item No. Qty Product Panelboards Qty Qty List of Materials 0A, P HFD Branch Breaker 0A, 3P HFD Branch Breaker 50A, 3P HJD Branch Breaker 400A, 3P HKD Branch Breaker 50A, 3P HFD Branch Breaker P HFD Branch Provision Only Copper Main Bus, 800 Amps Std. Bolted Cu Ground Bar (Cu Cable Only) Painted Box - ANSI 6 Device Nameplate Panel Nameplate - Orange with White Letters Type Enclosure: BX473P Standard Covers Description 4Circuits, 800A, Fully Rated, 480Y/77V 3Ph 4W, Copper Bus, 65k AIC, 800A, Main Lugs Only[Bottom Fed], Surface Mounted Catalog No Designation Item No. Clay Springs ES Product Panelboards P4D800LB30CH0 HDPB List of Materials 800A, Main Lugs Only Padlockable Hasp Lockoff Device Padlockable Hasp Lockoff Device Padlockable Hasp Lockoff Device 0A, P HFD Branch Breaker 40A, 3P HFD Branch Breaker 00A, 3P HFD Branch Breaker 70A, 3P HFD Branch Breaker 500A, 3P LGH Branch Breaker P HFD Branch Provision Only Copper Main Bus, 800 Amps Std. Bolted Cu Ground Bar (Cu Cable Only) Painted Box - ANSI 6 Device Nameplate Panel Nameplate - Orange with White Letters Type Enclosure: BX3673P Standard Covers Description Multi-Section Panel:Sections, 84Circuits, 5A, Series Rated, 08Y/0V 3Ph 4W, Copper Bus, 65k AIC, 5A, 3P ED Main Breaker[Bottom Fed], Surface Mounted Catalog No Designation Qty 47 PA5BB4CH0 LA List of Materials 5A, Main Lugs Only 5A, 3P ED Main Breaker 5A, Through-Feed Lugs 35A, P BAB Branch Breaker 0A, P BAB Branch Breaker Negotiation No: Alternate No: Page of 3 OR85070X4K 0007

10 Detail Bill of Material Project Name: General Order No: Qty 5 Clay Springs ES Negotiation No: Alternate No: Page 3 of 3 OR85070X4K 0007 List of Materials P BAB Branch Provision Only 70A, 3P BAB-H Branch Breaker 5A, P BAB Branch Breaker 30A, 3P BAB-H Branch Breaker 70A, FD Sub-Feed Breaker Copper Main Bus, 5 Amps Std. Bolted Cu Ground Bar (Cu Cable Only) Panel Nameplate - Black with White Letters Type Enclosure: EZB060R EZ Trim, Door in Door, Concealed Hardware: EZT060S Eaton Selling Policy applies. All orders must be released for manufacture within 90 days of date of order entry. If approval drawings are required, drawings must be returned approved for release within 60 days of mailing. If drawings are not returned accordingly, and/or if shipment is delayed for any reason, the price of the order will increase by.0% per month or fraction there of for the time the shipment is delayed.

11 General Information (Section of ) EHD A Bus Cover 5X EHD300 00A EHD00 EHD00 EHD00 EHD00 EHD00 EHD00 EHD A EHD300 00A Neutral Service Voltage: 480Y/77V 3Ph 4W Enclosure: Type Bus Rating & Type: 400A Copper Neutral Rating: 400A Ground Bar: Std. Bolted Copper, Cu cable only S.C. Rating: 65k A.I.C. Series Rated Main Device Type: Main Terminals: Neutral Terminals: Box Catalog No.: Trim: Box Dimensions: Min. Gutter Size: Main Breaker - Bottom Cable Entry Mechanical - () /0-500 kcmil () Mechanical - () #4-500 kcmil () EZB07R EZ Trim, Door in Door, Concealed Hardware (EZT07S) Surface Mounted 7.00" [88.8mm]H x 0.00" [88.8mm]W x 5.75" [46.mm]D Top = 5.5" [39.7mm] Bottom = 5.5" [39.7mm] Left = 4" [0.6mm] Right = 4" [0.6mm] Panel ID Nameplate: () HDPC Type: Plastic, adhesive-backed () 480Y/77V 3Ph 4W Color: Orange with White Letters (3) FED FROM MDP S CKT 3 NEC Lighting & Appliance, UL CTL Trim Lock: Standard Lock & Key (Keyed WEM) Circuit Directory: Plastic Sleeve with Card Main Circuit Breaker Trip Type: Thermal-Magnetic. Main Breaker 400A HKD3400, Vert Mtd. Device Modifications: Ref # Description Branch Devices Qty Poles Trip Frame Amps kaic 3 90 EHD EHD EHD EHD Notes: The information on this document is created by Eaton Corporation. It is disclosed in confidence and it is only to be used for the purpose in which it is supplied. PREPARED BY DATE SAM FAYLO 9/9/04 Eaton APPROVED BY DATE JOB NAME DESIGNATION Clay Springs ES HDPC VERSION TYPE DRAWING TYPE.0.0. PRL3a Customer Approval NEG-ALT Number OR85070X4K-0007 REVISION DWG SIZE G.O. 0 A ITEM SHEET of

12 General Information (Section of ) Bus Cover X FD375 75A FD350 50A EHD A EHD00 EHD00 EHD00 EHD00 EHD00 EHD00 FD A PROVEHD PROVEHD PROVEHD PROVEHD PROVEHD PROVEHD Neutral Service Voltage: 480Y/77V 3Ph 4W Enclosure: Type Bus Rating & Type: 400A Copper Neutral Rating: 400A Ground Bar: Std. Bolted Copper, Cu cable only S.C. Rating: 65k A.I.C. Series Rated Main Device Type: Main Terminals: Neutral Terminals: Box Catalog No.: Trim: Box Dimensions: Min. Gutter Size: Main Breaker - Bottom Cable Entry Mechanical - () /0-500 kcmil () Mechanical - () #4-500 kcmil () EZB07R EZ Trim, Door in Door, Concealed Hardware (EZT07S) Surface Mounted 7.00" [88.8mm]H x 0.00" [88.8mm]W x 5.75" [46.mm]D Top = 5.5" [39.7mm] Bottom = 5.5" [39.7mm] Left = 4" [0.6mm] Right = 4" [0.6mm] Panel ID Nameplate: () HDPA Type: Plastic, adhesive-backed () 480Y/77V 3Ph 4W Color: Orange with White Letters (3) FED FROM MDP S CKT 4 NEC Lighting & Appliance, UL CTL Trim Lock: Standard Lock & Key (Keyed WEM) Circuit Directory: Plastic Sleeve with Card Main Circuit Breaker Trip Type: Thermal-Magnetic. Main Breaker 400A HKD3400, Vert Mtd. Device Modifications: Ref # Description Branch Devices Qty Poles Trip Frame Amps kaic 3 75 FD FD EHD FD EHD PROVEHD Notes: The information on this document is created by Eaton Corporation. It is disclosed in confidence and it is only to be used for the purpose in which it is supplied. PREPARED BY DATE SAM FAYLO 9/9/04 Eaton APPROVED BY DATE JOB NAME DESIGNATION Clay Springs ES HDPA VERSION TYPE DRAWING TYPE.0.0. PRL3a Customer Approval NEG-ALT Number OR85070X4K-0007 REVISION DWG SIZE G.O. 0 A ITEM SHEET of

13 General Information (Section of ) Bus Cover 6X HJD350 50A HFD300 00A HFD30 0A HFD350 50A HKD A HFD00 HFD00 HFD00 HFD00 HFD00 HFD00 PROVHFD PROVHFD PROVHFD PROVHFD PROVHFD PROVHFD PROVHFD PROVHFD PROVHFD Main Lugs Only 800A Service Voltage: 480Y/77V 3Ph 4W Enclosure: Type Bus Rating & Type: 800A Copper Neutral Rating: 800A Ground Bar: Std. Bolted Copper, Cu cable only S.C. Rating: 65k A.I.C. Fully Rated Main Device Type: Main Terminals: Neutral Terminals: Box Catalog No.: Trim: Box Dimensions: Min. Gutter Size: Main Lugs Only - Bottom Cable Entry Mechanical - (3) #-500 kcmil () Mechanical - (3) #-500 kcmil () BX473P Standard Covers Surface Mounted 73.50" [866.9mm]H x 4.00" [866.9mm]W x 0.4" [64.mm]D Top = 0.65" [69.9mm] Bottom = 0.65" [69.9mm] Left = 5" [7.0mm] Right = 5" [7.0mm] Panel ID Nameplate: () HDPB Type: Plastic, adhesive-backed () 480Y/77V 3Ph 4W Color: Orange with White Letters (3) FED FROM MDP S3 CKT NEC Lighting & Appliance, UL CTL Circuit Directory: Plastic Sleeve with Card Painted Box: ANSI 6 Neutral Device Modifications: These Circuits have Modifications: Ckt #:, 7, 8, 4, 9, 5, 7, 9, 3, 33, 35 See Device Specifications page for details. Branch Devices Qty Poles Trip Frame Amps kaic HKD HJD HFD HFD HFD HFD PROVHFD Notes: The information on this document is created by Eaton Corporation. It is disclosed in confidence and it is only to be used for the purpose in which it is supplied. PREPARED BY DATE SAM FAYLO 9/9/04 Eaton APPROVED BY DATE JOB NAME DESIGNATION Clay Springs ES HDPB VERSION TYPE DRAWING TYPE.0.0. PRL4 Customer Approval NEG-ALT Number OR85070X4K-0007 REVISION DWG SIZE G.O. 0 A ITEM SHEET of 3

14 Pow-R-Line4 Device Specifications Ckt #s Nameplate Device Trip Terminal Modifications Padlockable Hasp Lockoff Device,,3 PANEL HMB HJD () #4-350 kcmil () 4,5,6 7,9, PANEL LB HFD () #4-/0 () Padlockable Hasp Lockoff Device 8,0, PANEL HB HFD30 0 () #4-4/0 () Padlockable Hasp Lockoff Device 4,6,8 PANEL LCB HFD () #4-4/0 () Padlockable Hasp Lockoff Device 9,0, FUTURE PORTABLES HKD () /0-500 kcmil () Padlockable Hasp Lockoff Device,3,4 6 PROVHFD 0 None Available 8 PROVHFD 0 None Available 30 PROVHFD 0 None Available 3 PROVHFD 0 None Available 34 PROVHFD 0 None Available 36 PROVHFD 0 None Available 38 PROVHFD 0 None Available 40 PROVHFD 0 None Available 4 PROVHFD 0 None Available 35 SPARE HFD00 0 () #4-/0 () Padlockable Hasp Lockoff Device The information on this document is created by Eaton Corporation. It is disclosed in confidence and it is only to be used for the purpose in which it is supplied. PREPARED BY DATE SAM FAYLO 9/9/04 Eaton APPROVED BY DATE JOB NAME DESIGNATION Clay Springs ES HDPB VERSION TYPE DRAWING TYPE.0.0. PRL4 Customer Approval NEG-ALT Number OR85070X4K-0007 REVISION DWG SIZE G.O. 0 A ITEM SHEET of 3

15 Pow-R-Line4 Device Specifications Ckt #s Nameplate Device Trip Terminal Modifications 33 SPARE HFD00 0 () #4-/0 () Padlockable Hasp Lockoff Device 3 SPARE HFD00 0 () #4-/0 () Padlockable Hasp Lockoff Device 5 SPARE HFD00 0 () #4-/0 () Padlockable Hasp Lockoff Device 7 SPARE HFD00 0 () #4-/0 () Padlockable Hasp Lockoff Device 9 SPARE HFD00 0 () #4-/0 () Padlockable Hasp Lockoff Device Main 800A-MLO (3) #-500 kcmil () The information on this document is created by Eaton Corporation. It is disclosed in confidence and it is only to be used for the purpose in which it is supplied. PREPARED BY DATE SAM FAYLO 9/9/04 Eaton APPROVED BY DATE JOB NAME DESIGNATION Clay Springs ES HDPB VERSION TYPE DRAWING TYPE.0.0. PRL4 Customer Approval NEG-ALT Number OR85070X4K-0007 REVISION DWG SIZE G.O. 0 A ITEM SHEET 3 of 3

16 General Information (Section of ) HFD300 00A Bus Cover X HFD A HFD A HFD00 PROVHFD HFD00 PROVHFD HFD00 PROVHFD HFD00 PROVHFD HFD00 PROVHFD HFD00 PROVHFD LGH A Main Lugs Only 800A Service Voltage: 480Y/77V 3Ph 4W Enclosure: Type Bus Rating & Type: 800A Copper Neutral Rating: 800A Ground Bar: Std. Bolted Copper, Cu cable only S.C. Rating: 65k A.I.C. Fully Rated Main Device Type: Main Terminals: Neutral Terminals: Box Catalog No.: Trim: Box Dimensions: Min. Gutter Size: Main Lugs Only - Bottom Cable Entry Mechanical - (3) #-500 kcmil () Mechanical - (3) #-500 kcmil () BX3673P Standard Covers Surface Mounted 73.50" [866.9mm]H x 36.00" [866.9mm]W x 0.4" [64.mm]D Top = 0.65" [69.9mm] Bottom = 0.65" [69.9mm] Left = 6" [5.4mm] Right = 8" [03.mm] Panel ID Nameplate: () HDPB Type: Plastic, adhesive-backed () 480Y/77V 3Ph 4W Color: Orange with White Letters (3) FED FROM MDP S3 CKT NEC Lighting & Appliance, UL CTL Circuit Directory: Plastic Sleeve with Card Painted Box: ANSI 6 Neutral Device Modifications: These Circuits have Modifications: Ckt #:, 7, 8, 3, 5, 7, 9,, 3, 5 See Device Specifications page for details. Branch Devices Qty Poles Trip Frame Amps kaic LGH HFD HFD HFD HFD PROVHFD Notes: The information on this document is created by Eaton Corporation. It is disclosed in confidence and it is only to be used for the purpose in which it is supplied. PREPARED BY DATE SAM FAYLO 9/9/04 Eaton APPROVED BY DATE JOB NAME DESIGNATION Clay Springs ES HDPB VERSION TYPE DRAWING TYPE.0.0. PRL4 Customer Approval NEG-ALT Number OR85070X4K-0007 REVISION DWG SIZE G.O. 0 A ITEM SHEET of 3

17 Pow-R-Line4 Device Specifications Ckt #s Nameplate Device Trip Terminal Modifications Padlockable Hasp Lockoff Device 5,6,7 PANEL HMB LGH () #-500 kcmil () 8,9,30,4,6 PANEL HB HFD () #4-/0 () Padlockable Hasp Lockoff Device 4 PROVHFD 0 None Available 7 SPARE HFD00 0 () #4-/0 () Padlockable Hasp Lockoff Device 9 SPARE HFD00 0 () #4-/0 () Padlockable Hasp Lockoff Device SPARE HFD00 0 () #4-/0 () Padlockable Hasp Lockoff Device 8,0, PANELLB HFD () #4-/0 () Padlockable Hasp Lockoff Device 7,9, PANEL LCB HFD () #4-/0 () Padlockable Hasp Lockoff Device 3 SPARE HFD00 0 () #4-/0 () Padlockable Hasp Lockoff Device 6 PROVHFD 0 None Available 5 SPARE HFD00 0 () #4-/0 () Padlockable Hasp Lockoff Device 8 PROVHFD 0 None Available 0 PROVHFD 0 None Available 3 SPARE HFD00 0 () #4-/0 () Padlockable Hasp Lockoff Device PROVHFD 0 None Available The information on this document is created by Eaton Corporation. It is disclosed in confidence and it is only to be used for the purpose in which it is supplied. PREPARED BY DATE SAM FAYLO 9/9/04 Eaton APPROVED BY DATE JOB NAME DESIGNATION Clay Springs ES HDPB VERSION TYPE DRAWING TYPE.0.0. PRL4 Customer Approval NEG-ALT Number OR85070X4K-0007 REVISION DWG SIZE G.O. 0 A ITEM SHEET of 3

18 Pow-R-Line4 Device Specifications Ckt #s Nameplate Device Trip Terminal Modifications 4 PROVHFD 0 None Available Main 800A-MLO (3) #-500 kcmil () The information on this document is created by Eaton Corporation. It is disclosed in confidence and it is only to be used for the purpose in which it is supplied. PREPARED BY DATE SAM FAYLO 9/9/04 Eaton APPROVED BY DATE JOB NAME DESIGNATION Clay Springs ES HDPB VERSION TYPE DRAWING TYPE.0.0. PRL4 Customer Approval NEG-ALT Number OR85070X4K-0007 REVISION DWG SIZE G.O. 0 A ITEM SHEET 3 of 3

19 General Information (Section of ) Cover inches Through-Feed Lugs BAB00 BAB00 BAB00 BAB00 BAB00 BAB00 BAB00 BAB00 BAB00 BAB00 BAB00 BAB00 BAB00 BAB00 BAB00 BAB00 BAB00 BAB00 BAB00 BAB00 BAB00 BAB00 BAB00 BAB00 BAB00 BAB00 BAB00 BAB00 BAB00 BAB00 BAB035 BAB05 BAB05 BAB05 BAB00 BAB00 BAB00 BAB PROV 36 BAB3070H Main Breaker 5A ED35, Vert Mtd. Service Voltage: 08Y/0V 3Ph 4W Enclosure: Type Bus Rating & Type: 5A Copper Neutral Rating: 5A Ground Bar: Std. Bolted Copper, Cu cable only S.C. Rating: 65k A.I.C. Series Rated Main Device Type: Main Terminals: Neutral Terminals: Through-Feed Lugs: Box Catalog No.: Trim: Box Dimensions: Min. Gutter Size: Main Breaker - Bottom Cable Entry Mechanical - () #4-4/0 () Mechanical - () #6-300 kcmil () Mechanical - () #6-300 kcmil () EZB060R EZ Trim, Door in Door, Concealed Hardware (EZT060S) Surface Mounted 60.00" [54.0mm]H x 0.00" [54.0mm]W x 5.75" [46.mm]D Top = 5.5" [39.7mm] Bottom = 5.5" [39.7mm] Left = 6.0" [5.4mm] Right = 6.0" [5.4mm] Panel ID Nameplate: () LA (sec ) Type: Plastic, adhesive-backed () 08Y/0V 3Ph 4W Color: Black with White Letters (3) FED FROM MDP S CKT 7 NEC Lighting & Appliance, UL CTL Trim Lock: Standard Lock & Key (Keyed WEM) Circuit Directory: Plastic Sleeve with Card Main Circuit Breaker Trip Type: Thermal-Magnetic. ***Non-Interchangeable Main Device*** Device Modifications: Ref # Description Branch Devices Qty Poles Trip Frame Amps kaic 35 BAB BAB BAB BAB PROV Notes: The information on this document is created by Eaton Corporation. It is disclosed in confidence and it is only to be used for the purpose in which it is supplied. PREPARED BY DATE SAM FAYLO 9/9/04 Eaton APPROVED BY DATE JOB NAME DESIGNATION Clay Springs ES LA VERSION TYPE DRAWING TYPE.0.0. PRLa Customer Approval NEG-ALT Number OR85070X4K-0007 REVISION DWG SIZE G.O. 0 A ITEM SHEET of

20 General Information (Section of ) Main Lugs Only 5A BAB00 BAB00 BAB00 BAB00 BAB00 BAB00 BAB00 BAB00 BAB00 BAB00 BAB00 BAB00 BAB05 BAB05 BAB PROV 50 5 PROV 5 53 PROV PROV PROV PROV 60 BAB3030H PROV PROV PROV PROV 70 7 PROV PROV 7 73 PROV PROV PROV PROV PROV PROV PROV PROV 80 8 PROV Sub-Feed Breaker 70A FD3070 Service Voltage: 08Y/0V 3Ph 4W Enclosure: Type Bus Rating & Type: 5A Copper Neutral Rating: 5A Ground Bar: Std. Bolted Copper, Cu cable only S.C. Rating: 65k A.I.C. Series Rated Main Device Type: Main Terminals: Neutral Terminals: Sub-Feed Breaker: Box Catalog No.: Trim: Box Dimensions: Min. Gutter Size: Main Lugs Only - Top Cable Entry Mechanical - () #6-300 kcmil () Mechanical - () #6-300 kcmil () Mechanical - () #4-/0 () EZB060R EZ Trim, Door in Door, Concealed Hardware (EZT060S) Surface Mounted 60.00" [54.0mm]H x 0.00" [54.0mm]W x 5.75" [46.mm]D Top = 5.5" [39.7mm] Bottom = 5.5" [39.7mm] Left = 6.0" [5.4mm] Right = 6.0" [5.4mm] Panel ID Nameplate: () LA (sec ) Type: Plastic, adhesive-backed () 08Y/0V 3Ph 4W Color: Black with White Letters (3) FED FROM MDP S CKT 7 NEC Lighting & Appliance, UL CTL Trim Lock: Standard Lock & Key (Keyed WEM) Circuit Directory: Plastic Sleeve with Card ***Non-Interchangeable Main Device*** Cover inches Device Modifications: Ref # Description Branch Devices Qty Poles Trip Frame Amps kaic 5 BAB BAB BAB PROV Notes: The information on this document is created by Eaton Corporation. It is disclosed in confidence and it is only to be used for the purpose in which it is supplied. PREPARED BY DATE SAM FAYLO 9/9/04 Eaton APPROVED BY DATE JOB NAME DESIGNATION Clay Springs ES LA VERSION TYPE DRAWING TYPE.0.0. PRLa Customer Approval NEG-ALT Number OR85070X4K-0007 REVISION DWG SIZE G.O. 0 A ITEM SHEET of

21 Technical Documents

22 0. Panelboards and Lighting Control Introduction Panelboards and Lighting Controls Contents Description Product Selection Guide 0 Product Selection Guide Product Types Type PRLa Fusible Lighting Panelboard PRLaF Type PRLa-LX Column Type Type PRLa Fusible Lighting Panelboard PRLaF Type PRLa-LX, Column Type Bolt-On or Plug-On Circuit Breakers 40 Vac Maximum Main lugs only 400A maximum Main Circuit breaker 400A maximum Branch circuit breakers 00A maximum, Single-, two- and three-pole 40 and 480Y/77 Vac Maximum Main lugs only 400A maximum Branch overcurrent protective devices 30A maximum, Single-, two and three-pole utilizing Class CC fuses Bolt-On Circuit Breakers 40 Vac Maximum Main lugs only 5A maximum Main circuit breaker 5A maximum Branch circuit breakers 00A maximum, Single-, two- and three-pole Bolt-On Circuit Breakers 40 or 480Y/77 Vac; 5/50 Vdc Maximum Main lugs only 400A maximum Main circuit breaker 400A maximum Branch circuit breakers 00A maximum, Single-, two- and three-pole 40 and 480Y/77 Vac Maximum Main lugs only 400A maximum Branch overcurrent protective devices 30A maximum, Single-, two- and three-pole utilizing Class CC fuses Bolt-On Circuit Breakers 40 or 480Y/77 Vac; 5/50 Vdc Maximum Main lugs only 5A maximum Main circuit breaker 5A maximum Branch circuit breakers 00A maximum, Single-, two- and three-pole 35 Volume Commercial Distribution CA EDecember 00

23 Panelboards and Lighting Control Introduction 0. Product Types, continued 0 Retrofit Panelboard PRL-R and PRL-R Type PRL3a Type PRL3E Type PRL4 Type PRL5P Bolt-On Circuit Breakers 480Y/77 Vac; 40 Vac, 480Y/77 Vac Main lugs only 5A maximum Main circuit breaker 5A maximum Branch circuit breakers 00A maximum, Single-, two and three-pole Bolt-On Circuit Breakers 40, 480 or 600 Vac; 50 Vdc Maximum Main lugs only 800A maximum Main circuit breaker 600A maximum Branch circuit breakers 5A maximum, Single-, two- and three-pole Bolt-On Circuit Breakers 40, 480Y/77 or 480 Vac; 50 Vdc Maximum Main lugs only 600A maximum Main circuit breaker 600A maximum Branch circuit breakers 5A maximum, Single-, two- and three-pole Circuit Breakers or Fusible Switches 40, 480 or 600 Vac; 600 Vdc Maximum Main lugs only 00A maximum Main circuit breaker 00A maximum Main fusible switch 00A maximum Branch circuit breakers 00A maximum, Single-, two- and three-pole Plug-On Circuit Breakers 40, 480 or 600 Vac; 50 Vdc Maximum Main lugs only 00A maximum Main circuit breaker 00A maximum Branch circuit breakers 00A maximum, Single-, two- and three-pole Branch fusible switches 00A maximum, two- and three-pole Product Types, continued Pow-R-Command Metering Service Section Elevator Control Panelboard Bolt-On Circuit Breakers 40 or 480Y/77 Vac Bolt-On Circuit Breaker or Fusible Switch 40, 480 or 600 Vac Bolt-On Fusible Switches 600 Vac Maximum Main lugs only 400A maximum Main circuit breaker 400A maximum Branch circuit breakers 5A maximum, Single-, two- and three-pole Integral power switching controls Service entrance panels combining a main disconnect with a power company metering compartment A Controls for up to four elevators in a single Panelboard Main lugs only 800A maximum Branch overcurrent devices 5 00A fusible switches with Class J fuse clips maximum Designed to meet specific sections of various codes impacting elevators Volume Commercial Distribution CA EDecember

24 Panelboards and Lighting Control Pow-R-Line C Panelboards 0.3 Pow-R-Line C Panelboards 0 Product Description Lighting and Distribution Panelboards Eaton s assembled panelboards are designed for sequence phase connection of branch circuit devices. This allows complete flexibility of circuit arrangement (single-, two- or three-pole) to allow balance of the electrical load on each phase. Sturdy, rigid chassis assembly ensures accurate alignment of interior with panel front; prevents flexing and minimizes possibility of loosening or damage to current carrying parts during and after installation. Four-point in-and-out adjustment of panel interior is provided to meet critical depth dimensions on flush installations. This compensates for possible misalignment of box at installation. Main lugs are mechanical solderless type and approved for copper or aluminum conductors. Enclosures Boxes are code-gauge galvanized steel, which include a painted box finished in ANSI-6 light gray to match the trim. Standard panelboard cabinets are designed for indoor use. Alternate types are available for indoor and special purpose applications. All enclosures are furnished in accordance with Underwriters Laboratories standards and include wiring gutters with proper wire bending space. Special cabinets can be provided at an additional charge. The box dimensions shown are inside dimensions. For outside dimensions, add /4-inch (6.4 mm). Standard panelboard boxes are supplied without knockouts (blank endwalls). Fronts Fronts (trims) for all panelboards are made of code-gauge steel and have a high durability ANSI-6 light gray finish applied by a bakedon polyester powder coating paint system. The fronts for lighting and appliance branch circuit panelboards and small power distribution panelboards include a door with rounded corners and concealed hinges. A flush-type latch and lock assembly is included. All locks are keyed alike. These trims are available in both surface- and flushmounted designs. The Three-Piece Trim for Larger Power Distribution Panelboards Provides for Easy Handling and Installation Fronts for power distribution panelboards utilize a unique breaker front cover design in which each device has a dedicated bolt-on steel cover. The individual covers form a single deadfront for the panelboard that is used in conjunction with two wiring gutter covers to complete the trim. A door is not finished as part of the standard offering on these panelboards but can be provided, for an additional charge, using a deeper than standard box. EZ Trim Features Standard Door-in-Door with No Exposed Hardware or Sharp Edges (no Tools are Required for Installation) Volume Commercial Distribution CA EDecember

25 0.3 Panelboards and Lighting Control Pow-R-Line C Panelboards Application Description 0 Panelboard Selection Factors In selecting a panelboard, the following factors must be considered: Service (voltage and frequency) Interrupting capacity (fully or series rated) Ampere rating of main Ampere ratings of branches Environment Panelboard Short-Circuit Rating The short-circuit rating of Eaton s assembled panelboards are test verified by, and listed with, Underwriters Laboratories (UL). Generally, these ratings are that of the lowest interrupting rated device in the panel. Certain exceptions to this rule exist where branch devices have been UL tested in combination with specific main devices having a higher interrupting rating. Where these defined main devices and branch breaker combinations are utilized, the series short-circuit rating of the assembled panelboard will be the same as the tested rating of the approved rated main device in series with the branches. Available main and branch breaker combinations are tabulated starting on Page 366. All combinations shown are UL tested and listed. These series ratings apply to panels having main devices, or main lug only panelboards fed remotely by the device listed in the series ratings chart as the main, for which UL listed tests were conducted. Service Entrance Equipment The National Electrical Code (NEC) requires that: A panel used as service entrance equipment must be located near the point where the supply conductors enter the building A panelboard having main lugs only shall have a maximum of six service disconnects to de-energize the entire panelboard from the supply conductors. Where more than six disconnects are required, a main service disconnect must be provided A disconnectable electrical bond must be provided between the neutral and ground A service entrance type UL label must be factory installed Ground fault protection of equipment shall be provided for each service disconnect rated 000A or more if the electrical service is a solidly grounded wye system of more than 50V to ground, but not exceeding 600V phase-to-phase Note: Service entrance panels must be identified as such on the order. Panelboard Standards In 008, both the National Electrical Code (Article 408) and UL 67 were updated to remove the mandated 4-circuit limitation. Eaton offers panelboards with more than 4 circuits for those jurisdictions that have adopted the 008 NEC or later. For jurisdictions that have not adopted the 008 or later version of the National Electrical Code, the 4-circuit limitation for Lighting and Appliance Branch Panelboards remains in place. Check with your local code officials to determine specific jurisdiction status. Panelboard Installation NEC requires that the operating handle of the topmost mounted device be no more than 6 feet 7 inches (006.6 mm) above the finished floor and should be installed per NEC and manufacturer s instructions. Additional boxes and fronts are required when the components required for one panelboard exceed the standard box dimensions. Multi-Section Panelboards When two or more separate enclosures are required, separate fronts for each box are standard. A common front can be furnished at additional charge. Interconnecting Multi- Section Panelboards When a panelboard, for connection to one feeder, must be furnished in more than one section (Box), each section must be furnished with main bus and terminals of the same rating, unless a main overcurrent device is provided in each section. Sub-feed or through-feed provisions must also be included (and priced) to provide connection capability to the second section. Note: Sub-feed or through-feed lugs cannot be used on any panelboard that is not protected by a single main overcurrent device either in the panelboard or immediately upstream, i.e., service entrance panelboards with main lugs only using the six disconnect rule. 358 Volume Commercial Distribution CA EDecember 00

26 Panelboards and Lighting Control Pow-R-Line C Panelboards 0.3 Sub-Feed Lugs Sub-feed lugs (see figure below) are one means of interconnecting multi-section panels. The sub-feed (second set of) lugs are mounted directly beside the main lugs. These are required in each section except the last panel in the lineup. The feeder cables are brought into the wiring gutter of the first section and connected to the main lugs. Another set of the same size cables are connected to the sub-feed lugs (Section ) and are carried over to the main lugs of the adjacent panel. Cross connection cables are not furnished by Eaton. Sub-feed lugs are only available on main lug only panels. Through-Feed Lugs Through-feed lugs (see figure below) are another method to interconnect multi-section panelboards. The incoming feeder cables are connected to the main lugs or main breaker at the bottom of panel (Section ). Another set of lugs (through-feed) are located at the opposite end of the main bus. The interconnecting cables are connected to the throughfeed lugs in Section and are carried over to the main lugs in Section. The connection arrangement could be reversed, i.e., main lugs at top; through-feed lugs at bottom end of panel. Cross cables are not furnished by Eaton. Multiple Section PanelboardFlush Mounted Shown below is the standard method for flush mounting multiple section lighting and distribution panelboards using standard flush trims. Multiple Section Panelboard Flush Mounted Dimensions in Inches (mm) Wall Trim Top Section View 3/4 (9.) Conduit Nipple for Cross Wiring by Contractor 3/4 (9.) Trim 3/4 (9.) / (38.) 3/4 (9.) 3/4 (9.) Trim Wall Contractor to Mount Boxes -/-inch (38. mm) Apart to Allow for 3/4-inch (9. mm) Extension on Both Flush Trims Outside Edge of Box 0 Note: Sub-feed lugs may not be used on main lug only (six disconnect rule) service entrance panels. Note: Through-feed lugs may not be used on main lug only (six disconnect rule) service entrance panels. Sub-Feed Lugs Through-Feed Lugs Box Box Box Box Cross Cables Main Lugs Panel Neutral Panel Neutral Neutral Main Lugs Conduit Conduit Incoming Feeder Cables Section Section Section Section Panel Thru Feed Lugs Panel Neutral 3/4 (9.) 3/4 (9.) Two Section Panelboard (Flush Mounting) 3/4 (9.) 3/4 (9.) 3/4 (9.) rim Extends 3/4-inch (9. mm) Beyond Outside of Box on All Four Sides Overcurrent Protection The following requirements will be found in the NEC: Each lighting and appliance branch circuit panelboard shall be individually protected on the supply side by not more than two main circuit breakers or two sets of fuses having a combined rating not greater than that on the panelboard. Volume Commercial Distribution CA EDecember

27 0.3 Panelboards and Lighting Control Pow-R-Line C Panelboards 0 Branch Circuit Loading for Lighting Panels The size of mains and branches should be selected based on the following: Motor circuits: NEC Article 430 Diversity factor Provision for future loading Exception Number : Individual protection for a lighting panelboard is not required when the panelboard feeder has overcurrent protection not greater than that of the panelboard. Exception Number : For existing installations, individual protection for lighting panelboards is not required where such panelboards are used as service equipment in supplying an individual residential occupancy and where any bus supplying 5 or 0A circuits is protected on the supply side by an overcurrent device. Ambient Temperatures The primary function of an overcurrent device is to protect the conductor and its insulation against overheating. In selecting the size of the devices and conductors, consideration should be given to the ambient temperature surrounding the conductors within and external to the panelboard. Cumulative heating within the panelboard may cause premature operation of the overcurrent protective devices. Underwriters Laboratories test procedures are based, in part, on 80% loading of panelboard branch circuit devices. The NEC limits the loading of overcurrent devices in panelboards to 80% of rating where in normal operation the load will continue for three hours or more. Further derating may be required, depending on such factors as ambient temperature, duty cycle, frequency or altitude. Exception: There is one exception to this rule in both UL and NEC. It applies to assemblies and overcurrent devices that have been listed for continuous duty at 00% of its rating. Special Conditions Standard panelboards, assembled with standard components, are adequate for most applications. However, special consideration should be given to those required for application under special conditions such as: Excessive vibration or shock Frequencies above 60 cycles Altitudes above 6600 feet (0.7m) Damp environment (possible fungus growth) Compliance with federal, state and municipal electrical codes and standards Seismic Considerations The Uniform Building Code and the International Building Code, as well as local and state building codes, place an emphasis on seismic building design requirements. Electrical distribution systems are treated as attachments to the building and therefore, fall into this category. All Eaton panelboards are seismic qualified at the highest possible level, and have been tested in accordance with ANSI C37.8. This standard quantifies actual earthquake conditions, as well as equipment seismic capability. Harmonic Currents Standard panelboard neutrals are rated for 00% of the panelboard current. However, since harmonic currents can cause overheated neutrals, an option is provided for neutrals to be rated at 00% (00A maximum neutral for 600A main bus) of the panelboard phase current. Panelboards with the 00% rated neutral are UL listed as suitable for use with nonlinear loads. Prior to specifying the 00% rated neutral, Eaton recommends a harmonic survey be conducted of the distribution system, be it new or existing. Surge Protective Devices The quality of power feeding sensitive electronic loads is critical to the reliable operation of any facility. In modern offices, hospitals, and manufacturing facilities, the most frequent causes of microprocessor-based equipment downtime and damage are voltage transients and electrical noise. Electrical loads and microprocessor-based equipment are highly susceptible to both high and low energy transients. High energy transients include lightning induced surges and power company switching. These high energy transients can destroy components instantly. More frequently the electrical system experiences low energy transients and high frequency noise. The effects of continual low energy transients and high frequency noise can cause erratic equipment performance or sudden failure of electronic circuit board components. Eaton can provide protective and diagnostic systems integral to panelboards. The surge protective device (SPD) is integrated into the panelboards using a zero lead length direct bus bar connection. Pow-R-Line 4 The SPD protects sensitive electronic equipment from the damaging effects of high and low energy transients, as well as high frequency noise. Standards and Certifications Eaton s panelboards are designed to meet the following applicable industry standards, except where noted: Underwriters Laboratories: Panelboards: UL 67 Cabinets and Boxes: UL 50 Note: Only panelboards containing UL listed devices can be UL labeled. National Electrical Code NEMA Standards: PB Federal Specification W-P-5c: Circuit Breakers Type I Class I Fusible Switch Type II Class I 360 Volume Commercial Distribution CA EDecember 00

28 Panelboards and Lighting Control Pow-R-Line C Panelboards 0.3 Technical Data and Specifications Panelboard Selection Guide Panelboard Type Maximum Voltage Rating Maximum Main Rating (Amperes) Device Type AC DC MLO Main Device Branch Circuits Ampere Range AC Interrupting Capacity rms Symmetrical Amperes (ka) Sub-Feed Breaker Maximum Amperes Fully Rated Series Rated 0 PRLa Breaker PRLR Breaker PRLaF Fusible PRLa-LX Breaker PRLa Breaker Breaker 480Y/ PRLR Breaker Breaker 480Y/ PRLaF Fusible 480Y/ PRLa-LX Breaker Breaker 480Y/ PRL3a Breaker Breaker Breaker PRL3E Breaker Breaker 480Y/ Breaker PRL4B Breaker Breaker Breaker PRL4F Fusible Fusible PRL5P Breaker Breaker Breaker PRC00/50 PRC5 Breaker Breaker 480Y/ Elevator Control Fusible Fusible 480Y/ Fusible Volume Commercial Distribution CA EDecember

29 0.3 Panelboards and Lighting Control Pow-R-Line C Panelboards 0 Terminal Wire Ranges, Pressure-Type Al/Cu Terminals Except as Noted Note: All terminal sizes are based Where copper-aluminum on wire ampacities corresponding terminals are supplied on to those shown in NEC Table designated panelboard types, 30-6 under the 75 C insulation best results are obtained if a columns (75 C wire). The use of suitable joint compound is smaller size, (in circular mills), regardless of insulation applied when aluminum temperature rating, is not conductors are used. permitted. Check Eaton s standard terminal sizes versus customer requirements. In particular, 400 and 800A breakers often require nonstandard lugs. Optional 750 kcmil mechanical screw-type terminals are available upon request. Panelboard dimensions may be affected, refer to Eaton. Standard Main Lug Terminals Wire Size Ranges for Ampere Capacity Panel Type 00A 5A 50A 400A 600A 800A 00A PRLa # /0 #6 300 kcmil () #4 500 kcmil PRLa # /0 #6 300 kcmil () #4 500 kcmil PRLR # /0 #6 300 kcmil () #4 500 kcmil PRLR # /0 #6 300 kcmil () #4 500 kcmil PRLaF # /0 #6 300 kcmil () #4 500 kcmil PRLaF # /0 #6 300 kcmil () #4 500 kcmil PRL3a # /0 #6 350 kcmil () #4 500 kcmil () #4 500 kcmil (3) #4 500 kcmil PRL3E # /0 #6 350 kcmil () #4 500 kcmil () #4 500 kcmil PRL4 #4 500 kcmil () #4 500 kcmil () #4 500 kcmil (3) #4 500 kcmil (4) #4 500 kcmil PRLa-LX # /0 #6 300 kcmil PRLa-LX # /0 #6 300 kcmil PRC00/PRC50 # /0 #6 350 kcmil () #4 500 kcmil PRC5 # /0 #6 300 kcmil () #4 500 kcmil PRL5P () #/0 500 kcmil () #4 500 kcmil () # 500 kcmil (4) #4 750 kcmil or () #/0 50 kcmil or (3) # 400 kcmil Elevator Control #4 500 kcmil () #4/0 500 kcmil () #4/0 500 kcmil (3) #4/0 500 kcmil 36 Volume Commercial Distribution CA EDecember 00

30 Panelboards and Lighting Control Pow-R-Line C Panelboards 0.3 Standard Circuit Breaker Terminals Breaker Type Ampere Rating Wire Range BAB, QBHW, BABRSP, 5 70 #4 #4 HQP, QPHW #8 /0 EDB, EDS, ED, EDH, EDC 00 5 #4 4/0 or #6 300 kcmil EGB, EGE, EGS, EGH 5 50 #4 3/0 AL/CU 60 5 #6 3/0 AL/CU EHD, FDB, FD, 5 00 #4 /0 HFD, FDC, HFDDC 5 5 #4 4/0 FCL 5 00 #4 /0 GHB, HGHB, GHQ, 5 0 #4 #0 GHQRSP 5 00 #0 /0 EGB, EGS, EGH 5 50 #4 / #6 /0 JD, HJD, JDC, HJDDC #4 350 kcmil DK kcmil 400 () 3/0 50 kcmil or () 3/0 500 kcmil KD, 5 () #3 350 kcmil HKD, KDC, HKDDC, CKD, CHKD 350 () 3/0 50 kcmil or 400 () 3/0 50 kcmil or () 3/0 500 kcmil LHH # 500 kcmil () # 500 kcmil () kcmil LGE, LGH, LGC, () # 500 kcmil LGU, LHH () # 500 kcmil LD, HLD, LDC, HLDDC () kcmil CLD, CHLD 600 () kcmil MDL, HMDL, HMDLDC () # 500 kcmil CMDL, CHMDL (3) 3/0 400 kcmil ND, HND, CND, CHND, NDC, (3) 3/0 400 kcmil CNDC 00 (4) 4/0 500 kcmil LCL 5 5 () #6 350 kcmil () #4 50 kcmil and () 3/0 600 kcmil FB-P 5 00 #4 /0 LA-P 70 5 #6 350 kcmil () #4 50 kcmil and () 3/0 600 kcmil NB-P, NBDC () # 500 kcmil 800 (3) 3/0 400 kcmil FDPW Switch Terminals Ampere Rating Wire Range 30 #4 /0 60 #4 /0 00 #4 /0 00 #4 300 kcmil kcmil or () 3/0 50 kcmil 600 () #4 600 kcmil or (4) 3/0 50 kcmil 800 (3) kcmil or (6) 3/0 50 kcmil 00 (4) kcmil or (8) 3/0 50 kcmil Elevator Control Panel Feeder Terminals Ampere Rating Wire Range 30 #4 /0 60 #4 /0 00 #4 /0 00 #4 300 kcmil Notes LHH is 400A maximum. Suitable for DC applications only. 0 Volume Commercial Distribution CA EDecember

31 7.4- Molded-Case Circuit Breakers & Enclosures Circuit Breaker Selection Data Series G Selection DataLG-Frame December 03 Sheet Series G, L-Frame Electronic RMS, A* Thermal-Magnetic, A* *UL Maximum is 600A L-Frame Breaker Table Dimensions in Inches (mm), Weight in Lbs (kg) Number Width Height Depth Weight of Poles (40) 4 7. (83) Table Thermal-Magnetic Trip Rating Frame Ratings Not UL listed. 0.3 (58) 0.3 (58) Table Digitrip 30+ Electronic Trip Units Frame Ratings 4.09 (04) 4.09 (04) LG 50, 300, 350, 400, 500, 600 LG 30, 630 LG_630 LG_600 LG_400 LG_50 6 (7.3) 0 (9.) 50, 300, 35, 350, 400, 500, 600, , 300, 35, 350, 400, 450, 500, , 00, 5, 50, 300, 35, 350, , 5, 50, 60, 75, 00, 5, 50 Note: 60, 35 and 630 are IEC ratings only. LG breaker is HACR rated. Table UL 489/IEC Interrupting Capacity Ratings Circuit Number Interrupting Capacity (ka rms Symmetrical Amperes) (ka) Breaker of Poles Volts AC (50/60 Hz) Volts DC Type Icu Ics Icu Ics Icu Ics Icu Ics LGE630 LGS630 LGH630 LGC630 LGU630 LGX630 3, 4 3, 4 3, 4 3, 4 3, 4 3, DC rating applies to substantially non-inductive circuits. Two-pole circuit breaker, or two poles of three-pole circuits. IEC rating is 300 ka at 40 Vac. Table Line and Load Terminals Maximum Breaker Amperes Terminal Body Material Aluminum Aluminum Copper Copper Aluminum Aluminum Copper Copper Aluminum Copper Wire Type Cu Cu Cu Cu Cu AWG Wire Range/Number of Conductors () () () () 500 () 500 () 500 () 500 () 500 () 500 () Metric Wire Range mm () () () () () () () () () () Includes LTS3K (three-pole) or LTS4K (four-pole) terminal covers. Standard terminal included with complete breaker Number of Terminals Included Catalog Number TA63LK 4TA63LK 3T63LK 4T63LK 3TA63LK 4TA63LK 3T63LK 4T63LK TA350LK T350LK For more information, visit: CA080400E

32 7.4-8 Molded-Case Circuit Breakers & Enclosures Circuit Breaker Selection Data Series C Selection DataK-Frame December 03 Sheet Series C, K-Frame Electronic RMS, A Thermal-Magnetic, A K-Frame Breaker Table Dimensions in Inches (mm) Number Width Height Depth of Poles, (39.7) 4 7. (83.4) 0.3 (57.) 0.3 (57.) Table Thermal-Magnetic Trip Ratings Frame Ratings DK, KDB, KD, HKD, KDC, HKDDC, Table Digitrip 30+ Electronic Trip Units Frame Ratings KD, CKD, HKD, CHKD, KDC 4.06 (03.) 4.06 (03.) 00, 5, 50, 75, 00, 5, 50, 300, 350, , 60, 70, 90, 00, 0, 5, 50, 60, 75, 00, 5, 50, 300, 35, 350, 400 Table Digitrip OPTIM Electronic Trip Unit Rating Plugs Frame Rating Plugs KD, CKD, HKD, CHKD, KDC 70, 90, 00, 0, 5, 50, 75, 00, 5, 50, 300, 350, 400 Table NEMA/UL 489/CSA Interrupting Capacity Ratings Circuit Number Trip Interrupting Capacity (Symmetrical Amperes) Breaker of Poles Type Volts AC (50/60 Hz) Volts DC Type DK KDB KD HKD KDC HKDDC CKD 3 CHKD 3, 3, 3, 4, 3, 4, 3, 4, 3, 4 3 N.I.T. N.I.T. I.T. I.T. I.T. I.T. I.T. I.T. N.I.T. is non-interchangeable trip; I.T. is interchangeable trip. Two-pole circuit breaker or two outside poles of three-pole circuit breaker. Time constant is 3 milliseconds minimum at 0 ka and 8 milliseconds minimum at ka. 8 milliseconds time constant. Current limiting. 00% rated. Two poles in series. Three poles in series. Table Line and Load Terminals Maximum Breaker Amperes Terminal Body Material Wire Type Standard Pressure Terminals Aluminum Aluminum 65,000 65,000 65,000 00,000 00,000 65,000 00,000 AWG/Wire Range/Number Conductors () () 35,000 35,000 65,000 00,000 35,000 65,000 5,000 5,000 35,000 65,000 5,000 35,000 Metric Wire Range (mm ) ,000 0,000 0,000,000,000 4,000 Catalog Number TA300K TA350K 400 Aluminum 3/0 50 () 95 0 TA400K 3TA400K 4TA400K Optional Copper and Pressure Type Terminals Copper Copper Cu Cu () () T300K T350K 400 Copper Cu 3/0 50 () 95 0 T400K 3T400K 4T400K 400 Aluminum /0 50 () or /0 500 () TA40K 3TA40K 4TA40K 400 Aluminum () TA40K 3TA40K 4TA40K 400 Copper () T40K 3T40K 4T40K Individually packed. Terminal kits contain one terminal for each pole and one terminal cover. Two-pole kit. Three-pole kit. Four-pole kit. Terminal kits contain one terminal for each pole and three interphase barriers. 35,000 For more information, visit: CA080400E

33 December 03 Sheet 703 Molded-Case Circuit Breakers & Enclosures Circuit Breaker Selection Data Series C Selection DataJ-Frame Series C, J-Frame Thermal-Magnetic, 70 50A J-Frame Breaker Table Dimensions in Inches (mm) Number Width Height Depth of Poles, (04.8) (39.7) 0.00 (54.0) 0.00 (54.0) 4.06 (03.) 4.06 (03.) Table Thermal-Magnetic Trip Ratings Frame Ratings JDB, JD, HJD JDC, HJDDC 70, 90, 00, 5, 50, 75, 00, 5, 50 Table UL 489 Interrupting Capacity Ratings Circuit Number Trip Interrupting Capacity (Symmetrical Amperes) Breaker of Poles Type Volts AC (50/60 Hz) Volts DC Type JDB JD HJD JDC HJDDC, 3, 3, 4, 3, 4 N.I.T. I.T. I.T. N.I.T. is non-interchangeable trip; I.T. is interchangeable trip. Two-pole circuit breaker or two outside poles of three-pole circuit breaker. Time constant is 3 milliseconds minimum at 0 ka and 8 milliseconds minimum at ka. 8 milliseconds time constant. Current limiting. Three poles in series. Two poles in series. Table Line and Load Terminals Maximum Breaker Amperes, 3, 4 3 I.T. I.T. Terminal Body Material Standard Pressure Terminals Aluminum Stainless steel 65,000 65,000 00,000 00,000 Wire Type Cu 35,000 35,000 65,000 00,000 AWG Wire Range () #4 350 kcmil () #4 350 kcmil UL listed for use with copper or aluminum conductors as noted. 8,000 8,000 5,000 35,000 0,000 0,000,000,000 4,000 35,000 Metric Wire Range (mm ) Catalog Number TA50KB T50KB CA080400E For more information, visit:

34 7.4-6 Molded-Case Circuit Breakers & Enclosures Circuit Breaker Selection Data Series C Selection DataF-Frame December 03 Sheet Series C, F-Frame Thermal-Magnetic 0 5A Electronic RMS 5 5A F-Frame Breaker Table Dimensions in Inches (mm) Number Width Height Depth of Poles (34.8).75 (69.9) 4.3 (04.8) 5.50 (39.7) 6.00 (5.4) 6.00 (5.4) 6.00 (5.4) 6.00 (5.4) 3.38 (85.7) 3.38 (85.7) 3.38 (85.7) 3.38 (85.7) Table Thermal-Magnetic Trip Ratings Frame Ratings ED, EDH, EDC 00, 5, 50, 75, 00, 5 EHD, FDB, FD, HFD, FDC, HFDDC FD, HFD, FDC 75, 00, 5 0, 5, 0, 5, 30, 35, 40, 45, 50, 60, 70, 80, 90, 00, 0, 5, 50 Table Digitrip 30+ Electronic Trip Units Types Frame Ratings FDE, HFDE, FDCE 5 00, 0, 5, 50, 60, 75, 00, , 70, 80, 90, 00, 5, 50, , 0, 30, 40, 50, 60, 70, 80 Table UL 489 Interrupting Capacity Ratings Circuit Number Trip Interrupting Capacity (Symmetrical Amperes) Breaker of Poles Type Volts AC (50/60 Hz) Volts DC Type EDB EDS ED EDH EDC, 3, 3, 3, 3, 3 EHD, 3 N.I.T.,000 4,000 N.I.T. 65,000 00,000 00,000 N.I.T. 8,000 FDC, 3, 4 N.I.T. 00,000 00,000 35,000,000 FDCE 5,000 HFDDC 3 N.I.T. 4,000 N.I.T. is non-interchangeable trip unit. Two-pole circuit breaker, or two poles of three-pole circuit breaker. Time constant is 3 milliseconds minimum at 0 ka and 8 milliseconds minimum at ka. Current limiting. Electronics available on three-pole only. HFDDC is UL only and is not tested to other standards. Interrupting rating is 35,000A at 600 Vdc with three poles in series, for ungrounded systems only. Table Line and Load Terminals 4,000 4,000 UL listed for use with copper or aluminum conductors as noted. Not for use with ED, EDH, EDC breakers. 0,000 0,000 0,000 0,000 0,000 0,000 0,000 FDB, 3, 4 N.I.T. 8,000 4,000 4,000 0,000 FD FD FDE HFD HFD HFDE Maximum Breaker Amperes, 3, 4, 3, 4, 3, 4, 3, 4 Terminal Body Material Standard Pressure Type Terminals 0 (EHD) Steel Steel Aluminum Aluminum Optional Pressure Terminals Aluminum Aluminum Stainless Steel Aluminum N.I.T. 65,000 65,000 N.I.T. 00,000 00,000 Wire Type Cu 35,000 65,000 AWG Wire Range () #4 #0 () #4 /0 () #4 4/0 () #4 4/0 () #4 #4 () #4 /0 () #4 4/0 () #6 300 kcmil 35,000 35,000 65,000 65,000 8,000 5,000 Metric Wire Range (mm ) ,000 0,000 0,000,000 Catalog Number Package of 3 Terminals 3T0FB 3T00FB 3TA50FB 3TA5FD 3TA50FB 3TA00FD 3T50FB 3TA5FDK For more information, visit: CA080400E

35 December 03 Sheet 70 Series C, G-Frame Thermal-Magnetic, 5 00A Molded-Case Circuit Breakers & Enclosures Circuit Breaker Selection Data Series C Selection DataG-Frame GHB Breaker and G-Frame Table G-FrameDimensions in Inches (mm) Number of Poles Width Height Depth P G-Frame P G-Frame 3P G-Frame GHCGFEP GHBGFEP Table Thermal-Magnetic Trip Ratings Frame Ratings GHB, GHC GHCGFEP, GHBGFEP GHQ HGHB Table UL 489 Interrupting Capacity Ratings Circuit Number Interrupting Capacity (ka Symmetrical Amperes) Breaker of Volts AC (50/60 Hz) Volts DC Type Poles Y/ GDB GD GD GHQ GHB GHB HGHB GHC GHC HGHC, 3 3, 3, Time constant is 8 milliseconds minimum. Two poles of three-pole circuit breaker. 5 70A breakers only. Table Terminal Types Circuit Breaker Amperes (5.4).00 (50.8) 3.00 (76.).00 (50.8).00 (50.8) 4.00 (0.6) 4.00 (0.6) 4.00 (0.6) 4.88 (4.0) 4.00 (0.6).8 (7.4).8 (7.4).8 (7.4).8 (7.4).8 (7.4) 5, 0, 5, 30, 35, 40, 45, 50, 60, 70, 80, 90, 00 5, 0, 30, 40, 50, 60 5, 0 5, 0, 5, Terminal Body Material Clamp (plated steel) Pressure (aluminum body) Clamp Pressure 4 4 Wire Type UL listed for use with copper or aluminum conductors as noted AWG Wire Range () #4 0 () #0 /0 () #4 #0 AWG () #0 /0 AWG GHCGFEP, GHBGFEP77V 30 ma GF Breaker Application Notes Type GHB are bolt-on panelboard breakers while type GHC is a cable-in and cable-out breaker for stand-alone mounting typically in a control panel or separate enclosure GHCGFEP and GHBGFEP are earth leakage breakers, rated for 30 ma ground fault protection On all three-phase delta (40V) grounded B phase applications, refer to Eaton 480Y/77V, circuit breakers (Type GHB) not suitable for three-phase delta (480V) grounded B phase applications All two- and three-pole circuit breakers are of the common trip type Single-pole circuit breakers, 5 and 0A. Switching duty rated (SWD) for fluorescent lighting applications Suitable for reverse-feed applications HACR rated Terminals Line side (on GHC) and load side (on GHC and GHB) terminals are UL listed as suitable for wire type and size listed below. When used with aluminum conductors, use joint compound. Table Terminals Breaker Amperes Terminal Type Clamp Pressure Wire Type Single Wire Range #4 #0 AWG #0 /0 AWG Figure Electrical Schematic Do not ground neutral anywhere on load side of breaker CA080400E For more information, visit:

36 December 03 Sheet 7087 Molded-Case Circuit Breakers & Enclosures Circuit Breaker Selection Data Selection DataQUICKLAG Industrial Circuit Breakers 7.4- QUICKLAG Industrial Circuit Breakers 3 4 HQP, QPHW, QHPX QPHW QPGF, QPHGF, QPGFEP, QPHGFEP Table QUICKLAG Industrial Circuit Breakers Type of Breaker Mounting/Electrical Connections Plug-On Thermal-Magnetic HQP, QPHW, QHPX Thermal-Magnetic QHPW Thermal-Magnetic QPGF, QPHGF, QPGFEP, QPHGFEP Two-pole interrupting ratings based on two poles connected in series. Not UL listed. Bolt-On Thermal-Magnetic BAB, QBHW, HBAX Thermal-Magnetic HBAW Circuit Breaker RatingsContinuous Current Rating at 40 C and 0 95% Humidity (Noncondensing) Amperes Poles Volts Amperes Poles Volts Amperes Poles Volts Amperes Poles Volts Amperes Poles Volts HQP QHPW QPGF BAB HBAW /40 0/ / / QPHW QPHGF QBHW /40 0/ / QHPX QPGFEP HBAX /40 0/ / /40 0/ /40 0/ /40 0/40 40 QPHGFEP /40 Dimensions in Inches (mm) Per Single-Pole Breaker W H D W H D W H D W H D W H D.00 (5.4).94 (74.6).38 (60.3).00 (5.4).94 (74.6).38 (60.3).00 (5.4) 3.9 (8.0).38 (60.3).00 (5.4).94 (74.6).38 (60.3) (5.4) (74.6) 0/40 40 AC Interrupting RatingsUL Listed Interrupting Ratings Shown (rms Symmetrical Amperes) Volts Amps I.R. Volts Amps I.R. Volts Amps I.R. Volts Amps I.R. Volts Amps I.R. HQP QHPW QPGF, QPGFEP BAB HBAW 0/40, 40 0,000 0/40, 40 65,000 0, 0/40 0,000 0/40, 40 0,000 0/40, 40 65,000 QPHW QPHGF, QPHGFEP QBHW 0/40, 40,000 0, 0/40,000 0/40, 40,000 QHPX HBAX 0/40, 40 4,000 0/40, 40 4,000 DC Interrupting Ratings Volts Poles Amps I.R. Volts Poles Amps I.R. Volts Poles Amps I.R. Volts Poles Amps I.R. Volts Poles Amps I.R Accessories and ModificationsSee MCCB CD-ROM for Description and UL Installation Status Moisture-fungus treatment Handle lock devices Shunt trip Special calibration Shock tested Dummy breaker Optional terminals Moisture-fungus treatment Handle lock devices Shunt trip Special calibration Shock tested Dummy breaker Optional terminals Moisture-fungus treatment Bell alarm contacts Auxiliary switch contacts BAB, QBHW, HBAX Moisture-fungus treatment Handle lock devices Shunt trip Special calibration Shock tested Panelboard accessories Dummy breaker Optional terminals HBAW -.38 (60.3) Moisture-fungus treatment Handle lock devices Shunt trip Special calibration Shock tested Panelboard accessories Optional terminals CA080400E For more information, visit:

2.7. Panelboards Solar Applications. Contents Description. Product Description. Pow-R-Line C Panelboards

2.7. Panelboards Solar Applications. Contents Description. Product Description. Pow-R-Line C Panelboards Panelboards Solar Applications.7 Contents Description Introduction.............................. Product Selection Guide.................. EZ Box and EZ Trim........................ Type PRL1a...........................

More information

Electrical Notes: For PDC-1 provide a minimum of 6 spare circuits.

Electrical Notes: For PDC-1 provide a minimum of 6 spare circuits. Waynetown Water System Improvements Division A -New Water Treatment Plant Town of Waynetown, IN Submittal Review Sheet Attached is the submittal for the Switchboards and Panelboards for the Waynetown Water

More information

PROJECT MANAGEMENT Transmittal No 17D

PROJECT MANAGEMENT Transmittal No 17D GH Phipps Construction Co. 5995 Greenwood Plaza Blvd. Suite 00 Greenwood Village CO 80-470 PROJECT MANAGEMENT Transmittal No 7D5780-00 PROJECT: Thistle-Valmont Square Interior & Exterior Renovation DATE:

More information

Panelboards and Lighting Control. Types PRL1a, 2a, 3a, 3E, 4 and Column Modifications. Contents Description

Panelboards and Lighting Control. Types PRL1a, 2a, 3a, 3E, 4 and Column Modifications. Contents Description .5 Types PRL1a, 2a, a, E, 4 and Column Modifications s Types PRL1a, 2a, a, E, 4, Column Modifications Selection Guide Modifications Alphabetical Index Modification Item Contents Types PRL1a, 2a, a, E,

More information

Panelboards. Panelboards Contents

Panelboards. Panelboards Contents -1 February 7 Contents Description Page EZ Box and EZ Trim.............................................. -2 Product Selection............................................... -4 Product Description.............................................

More information

Submittal Transmittal

Submittal Transmittal Submittal Transmittal Standard St. Joe's - Sonntag Pavillion St. Joseph s Hospital 350 W. Thomas Road Phoenix, AZ 85013 Project # 5690A Tel: Fax: Kitchell Contractors Inc of AZ Date: 9/12/2011 Reference

More information

Panelboards and Lighting Controls

Panelboards and Lighting Controls Product Guide and Lighting Controls Assembled Unassembled and Lighting Controls and Lighting Control Contents 1.1 Introduction Product Selection... 1-2 1.1 EZ Box and EZ Trim Product Description... 1-4

More information

EOEM panelboard and switchboard (OPS) Program

EOEM panelboard and switchboard (OPS) Program Instructional Leaflet IL02009EN EOEM panelboard and switchboard (OPS) Program OPS Program overview The OPS Program enables EOEMs to purchase panelboard/switchboard chassis, boxes, trims, molded-case circuit

More information

3.6. Panelboards and Lighting Control. Contents Description Product Overview... Product Selection Guide... Pow-R-Command 750 Panelboard...

3.6. Panelboards and Lighting Control. Contents Description Product Overview... Product Selection Guide... Pow-R-Command 750 Panelboard... .6 Panelboards and Lighting Control PRC25 Panelboard PRC25 Panelboard Product The PRC25 panelboard is designed to meet the needs for control of lighting and small branch circuits. Used as a standalone

More information

Pow-R-Line 3E Panelboard

Pow-R-Line 3E Panelboard This is a photographic template your photograph should fit precisely within this rectangle. Pow-R-Line 3E Panelboard 2008 Eaton Corporation. All rights reserved. Pow-R-Line 3E Panelboard Design guided

More information

6.1. Low Voltage Busway. Low Voltage Busway Pow-R-Way and 100V. Features, Benefits and Functions

6.1. Low Voltage Busway. Low Voltage Busway Pow-R-Way and 100V. Features, Benefits and Functions .1 Features, Benefits and Functions Pow-R-Way III Offers a Full Line of to Meet the Needs of the Global Marketplace Eaton Corporation has combined the requirements of NEMA, UL, CSA and IEC into one design

More information

COMMENTS: PLEASE SEE A/E COMMENTS

COMMENTS: PLEASE SEE A/E COMMENTS OCPS CLAY SPRINGS ES SUBMITTAL DETAILS: BUILDING REFERENCE: SUBJECT: DISTRIBUTION SWITCHBOARDS - RESUBMITTED 1 TIME(S) DATE RECIEVED: v 07, 2014 DISCIPLINE: Electrical PRIORITY STATUS: 2-STANDARD SPECIFICATION

More information

Cutler-Hammer. Molded Case Circuit Breakers Amperes. -" Product Selection M-Frame

Cutler-Hammer. Molded Case Circuit Breakers Amperes. - Product Selection M-Frame Cutler-Hammer Vol. 1, Ref. No. [0537] 300-800 Amperes 12-71 -" Product Selection Table 12-114. Types MDL and HMDL Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units Maximum Continuous Ampere

More information

Cutler-Hammer. Molded Case Circuit Breakers Amperes January J-Frame

Cutler-Hammer. Molded Case Circuit Breakers Amperes January J-Frame 12-34 70 - Amperes Cutler-Hammer Vol. 12-2 Product Line Overview Vol. 1, Ref. No. [0468] 12 Product Line Description Cutler-Hammer Molded Case Circuit Breakers are designed to provide circuit protection

More information

SECTION PANELBOARDS

SECTION PANELBOARDS SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under

More information

Applications. Trim are flat gauge steel per code. Standard painted finish ANSI 61 gray. Directory card with plastic cover on front of trim

Applications. Trim are flat gauge steel per code. Standard painted finish ANSI 61 gray. Directory card with plastic cover on front of trim Applications The CDP panels provide protection for lightning and power distribution circuits in the commercial and industrial establishments. The circuit breakers thermomagnetic trip allows for momentary

More information

Quik-Spec Coordination Panelboard Specifications

Quik-Spec Coordination Panelboard Specifications Quik-Spec Coordination Panelboard Specifications 30A - 400A Fusible Panelboards SECTION 26 24 XX (This Specification references CSI MasterFormat 2004) FUSIBLE BRANCH CIRCUIT PANELBOARDS PART 1 1.01 SUMMARY

More information

Detail Bill of Material Page 1 of 2 Project Name: Arc Eng Exposition Negotiation No: LAEC0706X6K1 General Order

Detail Bill of Material Page 1 of 2 Project Name: Arc Eng Exposition Negotiation No: LAEC0706X6K1 General Order Detail Bill of Material Page 1 of 2 Project Name: Negotiation No: LAEC0706X6K1 General Order Alternate No: 0000 No: Item No. Qty Product Description 1 Pow-R-Line C Switchboard, Front Access/ Front and

More information

2.3. Molded Case Circuit Breakers. Contents

2.3. Molded Case Circuit Breakers. Contents .3 Molded Case Circuit Breaker Product Family Product Overview Eaton s molded case circuit breakers are designed to provide circuit protection for low voltage distribution systems. They are described by

More information

6.1. Low Voltage Busway. Low Voltage Busway Pow-R-Way and 100V. Features, Benefits and Functions

6.1. Low Voltage Busway. Low Voltage Busway Pow-R-Way and 100V. Features, Benefits and Functions .1 Features, Benefits and Functions Pow-R-Way III Offers a Full Line of to Meet the Needs of the Global Marketplace Eaton Corporation has combined the requirements of NEMA, UL, CSA and IEC into one design

More information

A. Submit manufacturer's literature and technical data before starting work.

A. Submit manufacturer's literature and technical data before starting work. SECTION 16425 SWITCHBOARD PART 1 GENERAL 1.01 SUMMARY A. Related Section: 1. 16450 - Grounding. 1.02 SUBMITTALS A. Submit manufacturer's literature and technical data before starting work. B. Submit Shop

More information

SUBMITTAL TRANSMITTAL OCPS CLAY SPRINGS ES REVIEWED SUBMITTAL NUMBER: SUBMITTAL DETAILS: CONTRACTOR/CM:

SUBMITTAL TRANSMITTAL OCPS CLAY SPRINGS ES REVIEWED SUBMITTAL NUMBER: SUBMITTAL DETAILS: CONTRACTOR/CM: OCPS CLAY SPRINGS ES SUBMITTAL DETAILS: SUBJECT: MOTOR CONTROL BUILDING REFERENCE: DATE RECIEVED: Oct 09, 204 DISCIPLINE: Electrical PRIORITY STATUS: 2-STANDARD SPECIFICATION REF: 26 29 REVIEWER DUE DATE:

More information

Molded Case. Circuit Breakers. Molded Case Circuit Breakers Contents

Molded Case. Circuit Breakers. Molded Case Circuit Breakers Contents January 2001 Vol. 1, Ref. No. [0467] -1 Molded Case Circuit Breakers Contents Description Page Product Line Overview........................................... -2 Product Line Description.......................................

More information

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards 1 General 1.1 Switchboards shall be U.L. listed and labeled. 1.2 Each switchboard shall have its own main disconnecting means unless it is located in the same room as its source of origin. In most cases

More information

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein. 16425 SWITCHBOARD ************************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 26 24 13 An optional keynote to

More information

Vintage Westinghouse panelboards

Vintage Westinghouse panelboards Supersedes February 9 PRL1-LX PRL1 / PRL2 PRL CDP, HCDP FDP Contents Description Page Procedure for identifying renewal parts................................................... 2 Distributor ordering instructions.........................................................

More information

Switchboards Instant Service

Switchboards Instant Service January 1 Vol. 1, Ref. No. [0845] Switchboards Instant Service - Accessories Table -57. Meter Compartment Doors (Meter Sockets Not Included) Door Size Dimensions Drilling Inches mm H x 32 W 381.0 H x 8.8

More information

APPENDIX E. Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection Device Specifications

APPENDIX E. Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection Device Specifications Student Resource Building University of California Santa Barbara Clement Fung Lighting Electrical Option APPENDIX E Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection

More information

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS SECTION 26 28 16 ENCLOSED SWITCHES AND PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following individually mounted, enclosed switches and circuit breakers rated 600V AC and less: 1. Fusible switches.

More information

Molded Case Circuit Breaker Selection Guide. Replacement Breakers for Eaton Panelboards

Molded Case Circuit Breaker Selection Guide. Replacement Breakers for Eaton Panelboards Molded Case Selection Guide Replacement s for Eaton Panelboards Molded Case Selection Guide Product Range in Stock and Ready to Go Range KAIC @ 240Vac KAIC @ 277Vac KAIC @ 347Vac KAIC @ 600Vac Terminals

More information

Contents. General Electric Sangamo Astra CTB JCT-10 R6B TAB, TA CSF JCM-0 R6BA TCB, AA CMF JCW-0 R6M AB

Contents. General Electric Sangamo Astra CTB JCT-10 R6B TAB, TA CSF JCM-0 R6BA TCB, AA CMF JCW-0 R6M AB Panelboards and Lighting Control Metering Service Sections.7 Metering Service Section Contents Description Metering Service Sections Page Catalog Number Selection........................ 482 Product Selection..............................

More information

Selection and application guide

Selection and application guide Selection and application guide 30A 400A fusible panelboards Coordination Panelboard www.usa.siemens.com/fusiblepanel Coordination panelboards Table of contents Subject Page Specifications 2-3 Enclosure

More information

Table Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units

Table Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units -22 2 Amperes January 1 Vol. 1, Ref. No. [0488] Table -. FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Max. Cont. Ampere Rating @ 40 C 600V AC Maximum, 0V DC 277V AC Maximum,

More information

SECTION MOTOR CONTROL

SECTION MOTOR CONTROL SECTION 26 24 19 MOTOR CONTROL PART 1 - GENERAL 1.1 SECTION INCLUDES A. Manual motor starters B. Magnetic motor starters C. Combination magnetic motor starters D. Solid-state reduced voltage motor starters

More information

6.1. Low Voltage Busway. Low Voltage Busway Pow-R-Way and 100V. Features, Benefits and Functions

6.1. Low Voltage Busway. Low Voltage Busway Pow-R-Way and 100V. Features, Benefits and Functions .1 Low Voltage Busway Features, Benefits and Functions Pow-R-Way III Offers a Full Line of Low Voltage Busway to Meet the Needs of the Global Marketplace Eaton Corporation has combined the requirements

More information

Boxes C " wide, 5 3 4" deep. C " wide, 5 3 4" deep. Branch Breaker Side Gutters. Type Breaker (inches) C1 BL, BLH, HBL C2 BQD 3.

Boxes C  wide, 5 3 4 deep. C  wide, 5 3 4 deep. Branch Breaker Side Gutters. Type Breaker (inches) C1 BL, BLH, HBL C2 BQD 3. Circuit Breaker / Column Type Type C1 240 Volts AC Mains Branch UL Short Circuit Rating 200,000 IR Branch Breaker Symmetrical Interrupting Rating Based on Underwriters Test Procedure Type C2 480Y/277 Volts

More information

Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches

Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches 2 Bulletin 1494 NEMA Disconnect Switches Section Overview Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches Open Type, Fusible 30 600 A Open Type, Non-Fusible 30 600 A Page 2-3 Bulletin

More information

Introduction. P1 Panelboards. P1 Feature Overview. Contents. Siemens Panelboards Introduction to P1 Panelboards 1. General Specifications 3

Introduction. P1 Panelboards. P1 Feature Overview. Contents. Siemens Panelboards Introduction to P1 Panelboards 1. General Specifications 3 Introduction P1 Panelboards P1 Feature Overview Key Panelboard Features Lighting and Appliance Applications Power Panelboard Applications Convertible From Top Feed to Bottom Feed and Vice Versa Change

More information

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein. 16475 OVERCURRENT PROTECTIVE DEVICES ************************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 26 28 16 An optional

More information

Typical Specification Page 4. Introduction Page 5. Description Page 5. Circuit Breakers Page 5. Fuses Page 5. Circuit Protection and Continuity Page 5

Typical Specification Page 4. Introduction Page 5. Description Page 5. Circuit Breakers Page 5. Fuses Page 5. Circuit Protection and Continuity Page 5 Index Typical Specification Page 4 Introduction Page 5 Description Page 5 Circuit Breakers Page 5 Fuses Page 5 Circuit Protection and Continuity Page 5 Overcurrent Analysis - Fully Rated Page 6 Overcurrent

More information

Application guide. Tmax Link OEM UL 891 Switchboard Program

Application guide. Tmax Link OEM UL 891 Switchboard Program Application guide Tmax Link OEM UL 891 Switchboard Program 04 Tmax Link Overview 04 Standards 04 UL File Extension Process Overview 05 Electrical Data 05 Technical Data 05 Ambient Conditions 08 Circuit

More information

Panelboards Circuit Breaker / Lighting and Distribution

Panelboards Circuit Breaker / Lighting and Distribution Circuit Breaker / Lighting and Distribution 480Y/277 Vac Maximum 600Y/ 347 Vac (CSA only) Maximum 400 Ampere Mains 400 Ampere Maximum Branch UL Short Circuit Rating 200,000 A. @ 240 Vac / 100,000 A. @

More information

Division 1 Explosionproof Panelboards

Division 1 Explosionproof Panelboards Division 1 Explosionproof Panelboards Designed for use in Class 1, Division 1 Zone 1 areas such as petroleum refineries, chemical or petrochemical facilities, the X1Pb panelboards are used to control lighting

More information

X1PB: Explosionproof Panelboards

X1PB: Explosionproof Panelboards X1PB: Explosionproof FEATURES Spring-loaded through the door circuit breaker handles for 1P, 2P, and 3P breakers Padlock provision for breaker handles Copper bus bars Aluminum hinge with stainless steel

More information

Cutler-Hammer Molded Case Circuit Breakers Amperes. January 2001 Vol. 1, Ref. No. [0477] G-Frame

Cutler-Hammer Molded Case Circuit Breakers Amperes. January 2001 Vol. 1, Ref. No. [0477] G-Frame Cutler-Hammer January 200 Vol., Ref. No. [077] s Molded Case s 5-00 Amperes 2- 2-2 Product Line Overview January 200 Vol., Ref. No. [068] 2 Product Line Description Cutler-Hammer Molded Case s are designed

More information

Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA

Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA Table of Contents TPS NQ & AQ Series Overview 2 Switchboard Technical Data 3-5 Panelboard Technical Data 5-11 1 Tier Power

More information

Integrated Equipment Ratings

Integrated Equipment Ratings 14th Edition Integrated Equipment Ratings ka X X Z Z X @t 1 Z = 0 A =,000 @t 2 Z > 0 A

More information

Amperes. F-Frame. Price U.S. $ Catalog Number. Price U.S. $ EDH2100 EDH2125 EDH2150 EDH2175 EDH2200 EDH2225

Amperes. F-Frame. Price U.S. $ Catalog Number. Price U.S. $ EDH2100 EDH2125 EDH2150 EDH2175 EDH2200 EDH2225 January 1 Vol. 1, Ref. No. [0487] 2 Amperes - Product Selection Table -33. s,, and E Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Suitable for Reverse Feed Maximum Continuous Ampere

More information

Loadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta

Loadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta . Eaton Type CH Convertible Family Overview Product Selection Guide CH Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Three-phase, three-wire, 240V corner grounded delta Short-Circuit

More information

Design Standard. Purpose: Design Standard:

Design Standard. Purpose: Design Standard: Design Standard Purpose: This design standard has the purpose of creating a consistent application of motor-control centers throughout the East Side Union High School District, therefore achieving a standard

More information

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work Section 16435 - SWITCHBOARDS Introduction Part 1 - General Related Work Section 16070 Seismic Anchorage and Restraint Section 16075 Electrical Identification Section 16080 Power Distribution Acceptance

More information

Series C, F-frame molded case circuit breaker, 125A, Three-pole, Thermal magnetic trip. Thermal magnetic

Series C, F-frame molded case circuit breaker, 125A, Three-pole, Thermal magnetic trip. Thermal magnetic 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 HFD3125 HFD3125 125A 3P CKT BRKR Eaton Corp Catalog Number Manufacturer Description Weight per unit Product Category Features

More information

Table Types LD, HLD and LDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units

Table Types LD, HLD and LDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units -1 1 Amperes July 07 Product Selection Table -191. s, H and C Thermal-Magnetic Circuit s with Interchangeable Trip Units Maximum Continuous Ampere at 40 C 2-Pole 0 0 3-Pole 0 0 4-Pole 0 0 Magnetic trip

More information

Cutler-Hammer. Molded Case Circuit Breakers Amperes F-Frame. January 2001

Cutler-Hammer. Molded Case Circuit Breakers Amperes F-Frame. January 2001 2-22 0-225 Amperes F-Frame Cutler-Hammer January 200 Vol.,Ref. 2-2 Product Line Overview January 200 Vol., Ref. No. [0468] 2 Product Line Description Cutler-Hammer Molded Case Circuit Breakers are designed

More information

2.3. Molded Case Circuit Breakers. Series C. Accessories Selection Guide and Ordering Information

2.3. Molded Case Circuit Breakers. Series C. Accessories Selection Guide and Ordering Information Molded Case Circuit s Series C.3 Accessories Selection Guide and Ordering Information Line and load terminals provide wire connecting capabilities for specific ranges of continuous current ratings and

More information

Dry-Type Transformers Mini-Power Centers

Dry-Type Transformers Mini-Power Centers Dry-Type Transformers Mini-Power Centers Product Focus Three individual components combined into a single unit to save space and costs, 3 to 30 kva Dry-Type Transformers Mini-Power Centers Significant

More information

Series C, F-frame molded case circuit breaker, 15A, Two-pole, Thermal Magnetic Trip, FD Breaker

Series C, F-frame molded case circuit breaker, 15A, Two-pole, Thermal Magnetic Trip, FD Breaker FD2015 2 Pole 15A FD Eaton Corp Catalog Number Manufacturer Description Weight per unit Product Category Features amperage rating 15 Frame Size F-frame interrupt rating 35 kaic at 480V Poles 2 Trip Type

More information

BUSWAY Low Voltage (Pow-R-Flex)

BUSWAY Low Voltage (Pow-R-Flex) BUSWAY LOW VOLTAGE (POW-R-FLEX) PART 1 GENERAL 1.01 1.02 SCOPE The Contractor shall furnish and install the busway system including all necessary fittings, hangers and accessories as specified herein and

More information

PANELBOARDS C1/C2 SECTION 6

PANELBOARDS C1/C2 SECTION 6 SECTION 6 C1/C2 PANELBOARDS Page General Specifications 6-2 Box Sizing 6-2 Gauge Steel Boxes 6-2 Fronts 6-2 Main Breaker Connectors 6-2 Main Lug Connectors 6-2 Selection 6-3 6-5 Main Lugs Only C1 and C2

More information

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 29 21 ENCLOSED SWITCHES AND CIRCUIT BREAKERS SPEC WRITE NOTE: Delete between // // if not applicable to project. Also delete any other item or paragraph not

More information

Bulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers

Bulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers Bulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers Bulletin 1494D Fixed Depth Flange Mounted Circuit Breaker Operating Mechanism Industrial rated circuit breaker operating mechansim pre-assembled

More information

D2LC Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments

D2LC Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments D2LC Series Circuit Breaker Panelboards for Harsh and Hazardous Environments IBUTI TR HA ON DIS KILLARK Z LO C Type 4X Gasket Stainless Steel Tri-Lead Cover Bolts Spare Sealed Wires Termination at Terminal

More information

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE PAGE 261116-1 SECTION 261116 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

WARREN COUNTY, N.Y. M/E REFERENCE

WARREN COUNTY, N.Y. M/E REFERENCE SECTION 262000 - ELECTRIC DISTRIBUTION PART 1 - GENERAL 1.1 DESCRIPTION A. Provide a complete secondary distribution system as indicated on the Contract Documents and as specified herein. 1.2 QUALITY ASSURANCE

More information

Fused Coordination Panelboard

Fused Coordination Panelboard Fused Coordination Panelboard SOLUTIONS GUIDE SOLUTIONS GUIDE Branch Circuit Protection Introducing Mersen s Fused Coordination Panelboard Selective Coordination is required in several locations as defined

More information

5.11. Metering Products 3 MTB 400 R C. Group Metering. Catalog Number Selection

5.11. Metering Products 3 MTB 400 R C. Group Metering. Catalog Number Selection .11 Selection Phase 1 = Single-phase 3 = Three-phase Type of Metering BTB = Main terminal box MCB = Main circuit breaker BPS = Bolted pressure switch MFS = Main fusible switch UGPB = Underground pull box

More information

Multi-Pak Group Control

Multi-Pak Group Control Multi-Pak Grouping.1 Product....................................... Application.................................... Features Enclosures........................................... V-T-2 V-T-2 V-T-2 Feeder

More information

Lighting Panelboards. P2 Panelboards

Lighting Panelboards. P2 Panelboards Lighting Panelboards P2 Panelboards Features Flexibility is the hallmark of the P2 panel. This panel offers a wide array of factory-assembled options to meet virtually any lighting panel application. The

More information

Quik-Spec Coordination Panelboard A fusible panelboards

Quik-Spec Coordination Panelboard A fusible panelboards Supersedes July 2018 Quik-Spec Coordination Panelboard 30-400 fusible panelboards Contents Description Page Specifications... 2-3 Enclosure types and voltages/systems.... 4 using, main and feed-through

More information

type P1 Lighting and Power Distribution Panelboards Overview P1 Panelboards

type P1 Lighting and Power Distribution Panelboards Overview P1 Panelboards type P Lighting and Power Distribution Panelboards Specifications Main Breaker: 400A Maximum Main Lugs only: 400A Maximum Voltages: 480Y/277V AC Maximum 250V DC Maximum 3Ø3W, 3Ø4W, Ø3W, Ø2W General P panelboards

More information

Panelboard Renewal Parts Supplement

Panelboard Renewal Parts Supplement Panelboard Renewal Parts Supplement Contents Page Page Contents Page PRL 1a and a Neutral Assemblies..................................................... 3 PRL 1a and a Ground Assemblies.......................................................

More information

Quik-Spec Coordination Panelboard A fusible panelboards

Quik-Spec Coordination Panelboard A fusible panelboards USSMNN Supersedes December 2015 SERIES Quik-Spec Coordination Panelboard 30-400 fusible panelboards Contents Description Page Specifications.... 2-3 Enclosure types and voltages/systems.... 4 using, main

More information

4.5. Switchboards. Contents Description Instant Service Switchboards Product Selection...

4.5. Switchboards. Contents Description Instant Service Switchboards Product Selection... .5 Type 1 Indoor Product Description Eaton s Instant are designed as stocked units to provide fast delivery to match the needs of the construction market. Suitable for use as service entrance equipment,

More information

Cutler-Hammer. January 2001

Cutler-Hammer. January 2001 Cutler-Hammer Vol. -2 Product Line Overview Vol. 1, Ref. No. [0468] Product Line Description Cutler-Hammer Molded Case s are designed to provide circuit protection for low voltage distribution systems.

More information

Architecture - Engineering - Planning

Architecture - Engineering - Planning rchitecture - Engineering - Planning www.mkcinc.com Mansfield, Ohio New Philadelphia, Ohio Powell, Ohio 419-525-1102 - phone 330-364-8871 - phone 740-657-3202 - phone 419-525-1428 - fax 330-343-3075 -

More information

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide. .2 Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase loadcenters 70 225A, 8 to 42

More information

Cutler-Hammer. January 2001

Cutler-Hammer. January 2001 Vol. 12-2 Product Line Overview Vol. 1, Ref. No. [0468] 12 Product Line Description Cutler-Hammer Molded Case Circuit Breakers are designed to provide circuit protection for low voltage distribution systems.

More information

Engine Generator Circuit Breakers

Engine Generator Circuit Breakers Engine Generator Circuit Breakers Product Description............................................. 2 Application Description........................................... 2 Standards and Certifications......................................

More information

100-Ampere Busway. Effective November 2005 New Information. Elbow, Busway and Cable Tap Box. Technical Data TD E

100-Ampere Busway. Effective November 2005 New Information. Elbow, Busway and Cable Tap Box. Technical Data TD E 100-Ampere Busway Technical Data TD01701002E Effective November 2005 New Information Elbow, Busway and Cable Tap Box Contents General Information.............................. 2 Connections...............................

More information

Customer Requirements Downtown Secondary Network Service

Customer Requirements Downtown Secondary Network Service Application This standard describes the limitations and requirements for receiving service from the Tacoma Power secondary network system within the City of Tacoma downtown core area. In This Standard

More information

Pow-R-Line panelboards

Pow-R-Line panelboards Price List PL01400001E Supersedes January 2008 Pow-R-Line panelboards Table 1. Catalog numbers and pricing Trim lock 1A32258H03 234.00 PRL1a connector kit 1C96608G01 412.00 1C96608G03 532.00 1C96608G05

More information

IN2 Enclosed Switches and Circuit Breakers

IN2 Enclosed Switches and Circuit Breakers Illinois Math and Science Academy DigitalCommons@IMSA Project Manuals IN2 2015 IN2 Enclosed Switches and Circuit Breakers Illinois Mathematics and Science Academy Follow this and additional works at: http://digitalcommons.imsa.edu/facility_in2_manuals

More information

Unassembled Pow-R-Stock panelboards EZE Boxes and EZ Trims

Unassembled Pow-R-Stock panelboards EZE Boxes and EZ Trims Unassembled Pow-R-Stock EZE Boxes and EZ Trims Single-Phase, -Wire 10/40 Catalog Number Interiors (Less Main Device) mpere Max. No. of Poles luminum Bus Copper Bus 0 18 PRL110X18 PRL110X18C 0 0 PRL110X0

More information

QMB Fusible Panelboards

QMB Fusible Panelboards Catalog 4620CT9601R04/09 2009 Class 4620 CONTENTS Description............................................. Page Overview.............................................. Page 3 QMB Switches..........................................

More information

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT SECTION 16400 LOW VOLTAGE DISTRIBUTION EQUIPMENT A. General 1. The University does not accept Series-Rated equipment for power distribution switchboards, distribution panels and branch circuit panelboards.

More information

Laser Service Factory-assembled Panelboards

Laser Service Factory-assembled Panelboards Factory-assembled Panelboards Price List 1600PL0701 2009 Class 1600 CONTENTS Description............................................. Page Product Overview........................................ Page

More information

PANELBOARDS SECTION 1

PANELBOARDS SECTION 1 SECTION 1 P1 PANELBOARDS Description Page General Information 1-2 Selection and Application 1-2 Application 1-3 1-6 Main Breaker Panel Size Selector 1-3 Main Breaker Selection 1-3 Main Lugs Size Selector

More information

Amperes. F-Frame. Price U.S. $ Catalog Number. Price U.S. $ EDH2100 EDH2125 EDH2150 EDH2175 EDH2200 EDH2225

Amperes. F-Frame. Price U.S. $ Catalog Number. Price U.S. $ EDH2100 EDH2125 EDH2150 EDH2175 EDH2200 EDH2225 January 1 Vol. 1, Ref. No. [0487] 2 Amperes 12- Product Selection Table 12-33. s, H, and E Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Suitable for Reverse Feed Maximum Continuous

More information

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5 DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5 1.1. APPLICABLE PUBLICATIONS 1.1.1. Publications listed below (including amendments, addenda, revisions, supplements, and errata), form a part of this

More information

Service Entrance Methods

Service Entrance Methods Service Section Typical switchboards consist of a service section, also referred to as the main section, and one or more distribution sections. The service section can be fed directly from the utility

More information

Specification Number: Product Name: GROUP MOUNTED MAIN FUSIBLE SWITCH, GROUP MOUNTED BRANCH FUSIBLE SWITCH (LONG) SECTION

Specification Number: Product Name: GROUP MOUNTED MAIN FUSIBLE SWITCH, GROUP MOUNTED BRANCH FUSIBLE SWITCH (LONG) SECTION Specification Number: 26 24 13.20 Product Name: GROUP MOUNTED MAIN FUSIBLE SWITCH, GROUP MOUNTED BRANCH FUSIBLE SWITCH (LONG) SECTION 26 24 13.20 SWITCHBOARDS (Long) Main Disconnect Group Mounted Fusible

More information

6.2. Power Pedestals. Contents

6.2. Power Pedestals. Contents Power Pedestals.2 Power Outlet Panels Contents Description Page Product Overview................................. 287 Application Description.......................... 288 Features and Benefits...........................

More information

XP Series Pre-Wired Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof System

XP Series Pre-Wired Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof System NEC/ Applications Protection and control of electrical apparatus and circuits in hazardous environments, either indoor or outdoor. Designed for Class I, Division 2 areas where flammable gases or vapors

More information

GE Energy. GE Panelboards. The right panelboard for any application. imagination at work

GE Energy. GE Panelboards. The right panelboard for any application. imagination at work GE Energy GE Panelboards The right panelboard for any application imagination at work GE Panelboards Right on design, right on manufacture, right on service From design through manufacture and delivery,

More information

DISTRIBUTION EQUIPMENT: NEC/CEC HAZARDOUS LOCATION SWITCHES. Application

DISTRIBUTION EQUIPMENT: NEC/CEC HAZARDOUS LOCATION SWITCHES. Application - and 3-Pole, Non-Interchangeable Trip. Bolted Enclosure Type. Class I, Division 1 and, Groups B, C, D Class II, Division 1 and, Groups E, F, G Application Explosionproof circuit breaker enclosures are

More information

RCS1000 Data Sheet. RCS1000 Series Controllable Circuit Breaker Panel

RCS1000 Data Sheet. RCS1000 Series Controllable Circuit Breaker Panel RCS000 Series Controllable Circuit Breaker Panel RCS000 Data Sheet Overview The RCS000 Series Controllable Circuit Breaker Panels combines the benefi ts of traditional relay based load control and the

More information

Medium Voltage Metal-Enclosed Switches

Medium Voltage Metal-Enclosed Switches Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Medium Voltage Switch MVS Product Description............................................. 2 Application Description..........................................

More information

AMENDMENT ELECTRIC SERVICE MANUAL 2014

AMENDMENT ELECTRIC SERVICE MANUAL 2014 AMENDMENT (Pages 20,43,50,72,74,,76,78,83,86,99) ELECTRIC SERVICE MANUAL 2014 Effective April 1, 2015 18-7 6.0 SERVICE AND SERVICE ENTRANCES (General), Continued Conductor Sizing It is recommended that

More information

NEC/CEC CLASS/ZONE RATED HAZARDOUS LOCATION CIRCUIT BREAKERS. Application

NEC/CEC CLASS/ZONE RATED HAZARDOUS LOCATION CIRCUIT BREAKERS. Application - and 3-Pole, Non-Interchangeable Trip. Bolted Enclosure Type. Class I, Division 1 and, Groups B, C, D Class II, Division 1 and, Groups E, F, G Distribution Equipment NEC/CEC CLASS/ZONE RATED HAZARDOUS

More information

A. Work Included: Provide low voltage switchboard work as shown, scheduled, indicated, and as specified.

A. Work Included: Provide low voltage switchboard work as shown, scheduled, indicated, and as specified. SECTION 26 24 13 LOW VOLTAGE SWITCHBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General

More information