1 SOLAR THERMAL EQUIPMENT
2 6 DIRECT FLOW CPC COLLECTOR Rhico direct flow CPC collectors are acknowledged as the market s premium product. With an extremely low heat loss and optically efficient cylindrical absorber, our vacuum tube collector range is probably the best in the world, offering a high output from a small surface area thanks to our CPC (compound parabolic concentrator), which redirects normally wasted energy back to the absorber surface increasing the collectors aperture area. Known as one of the most versatile vacuum tube collectors available, it can be installed on a tiled roof, vertical, horizontal, landscape, portrait and on a flat roof with non-penetrable roof system. years collector warranty Attributes: Impact resistant to hail Suits all applications from horizontal to vertical Non-penetrable roof system Quick and easy to install Optically efficient cylindrical absorber Highest output available from a small surface area year warranty year life expectancy Rhico Pro-Plus Range: Product Code Type Gross area Active absorber surface Aperture area Weight Join Absorber Glass Absorption Emission Max. Operating pressure Test pressure Max. Temperature Power in addition to irradiation Dimensions Width (with fittings) Height Depth 8 Tube Collector Tube Collector ST-VTC-7 Direct Flow "U" tube.m².m².88m² 6kg /" thread Cr-Al-N / Cu three layers Borosilicate. 95% 5% 6 bar 5 bar 86 C W / m² W ST-VTC-7 Direct Flow "U" tube.88m².5m².5m² 5.5kg / "thread Cr-Al-N / Cu three layers Borosilicate. 95% 5% 6 bar 5 bar 86 C W / m² 88W Dimensions 95 mm 6 mm 95 mm Dimensions 5 mm 6 mm 95 mm
3 Rhico Solar Thermal PRO PLUS 8CPC Collector Dimensions 7 PRO PLUS CPC Collector Dimensions
4 Rhico Solar Thermal Roof Mounting Options Tiled Roof Product Code: ST-RMK- 8 Flat Roof Product Code: ST-RMK-8
5 Rhico Solar Thermal Roof Mounting Options Non Penetrable Roof Collector Product Code: ST-MPRMS-S-86 9 Collectors Product Code: ST-MPRMS-D-87
6 Rhico Solar Thermal Roof Mounting Options Non Penetrable Roof Collector Product Code: ST-MPRMS-T-88 Collectors Product Code: ST-MPRMS-Q-89
7 Rhico Solar Pump Stations Vertigo VRD-9 Sliding cover to access to the buttons. VERTIGO VRD-9 is a solar station with variable flow rate - l/min. The feature that makes it unique is the installation of several digital solar controllers, regardless of their size and dimensions. In order to protect the digital solar controllers from the overheating, VERTIGO VRD-9 is equipped with an insulation that totally separates the solar station from the digital controller. The frontal covering case has an air intake that allows the right aeration of the electronic device. VERTIGO VRD-9 can also be equipped with electronic low energy pump. MAIN CHARACTERISTICS Flow rate regulator l/min. Insulation protection of the controller. Filling/draining/flushing of the system and disassembling of the pump without having to empty the system. Compact safety unit includes safety valve, manometer and connection for flexible tube for expansion vessel. Lateral hole for heat sinking pump. Modulating pumps ("A" class) can be installed. On-wall assembling or directly to the storage tank. Ball valve with thermometers and check valves. Insulation in black EPP g/l. All seals are assured by flat fittings and gaskets.
8 - + 6 C C bar 8 Rhico Solar Pump Stations Vertigo VRD-9 Pump characteristics (max. speed) - Pressure loss 9 Controller, flexible tube and expansion tank wall support bracket are supplied separately. See "Solar station accessories" P (m H O) 8 78, Grundfos UPS SOLAR , , P (kpa) 6 9, 9, 9,6 9,8 nr. Nose cone connection kit for Cu pipe Ø mm 6 8 Q (l/h) DN VERTIGO VRD-9 (without controller) Without pump With UPS Solar5-65 (without cable) Code TECHNICAL DATA Check valve opening 5 mm H O Components n. Flow rate regulator l/min with fll/drain tap/cleaning plant Flow ball valve DN VRR Return ball valve DN VRM with check valve Flow pipe with integral degasser Red handle Blue handle Thermometers Nuts Safety unit with - bar manometer, 6 bar safety valve, connection to expansion tank Wall support bracket Gaskets Pump on the return side Insulation Nose cone connection kit for Cu pipe Ø mm Nominal diameter Max pressure Max temperature Ball valve material Check valve material Insulation material Gaskets material Station height Insulation dimensions DN - ¾" 8 bar C MS 58 brass MS 58 brass EPP schwarz g/l black EPP g/l Viton - Centellen mm x6x mm Projected for Accessories SOREL STECA RESOL KROMSCHRÖDER STECA SEITRON Nose cone connection kit for Cu pipe Ø /5/8 mm, consisting of nr. tube supports for pipe Ø 5/8 mm, nr. reduction bushings Ø /5/8 mm. male joint tube supports for pipe Ø 5/8 mm reduction bushings Ø /5/8 mm copper pipe Ø /5/8 mm BRAHMA TIEMME TIEMME nut (supplied with solar station) Accessories Code Nr. nose cone connection kit for Cu pipe Ø 5 mm Transition straight fitting ¾" M 9 7 ¾" Transition straight fitting ¾" M for corrugated steel pipe.! For "VERTIGO VRD-9",it's necessary to order nose cone connections kits.
9 Rhico Solar Pump Stations Maverick VRD-9 MAVERICK VRD-9 is a forced circulation solar station where different combinations of electronic management and flow rate regulation can be installed to get a product with different characteristics. The possibility to assemble different types of flow rate regulators makes it a versatile system to satisfy small and large plants. The controller allows us to manage up to 5 different types of plants and is equipped with pictogram display. MAVERICK VRD-9 can directly be installed on the wall or on a solar tank through a fixing bracket (supplied with the kit). MAIN CHARACTERISTICS Insulation to protect of the controller. working ranges of the flow rate regulator:,5 6 l/min, 5 l/min and 5 l/min. Filling / draining / flushing of the system and disassembly of the pump without having to empty the system. Internal degasser into flow pipe. Compact safety unit includes safety valve, manometer and flexible connection for expansion tank. Lateral hole for heat sinking pump. On-wall assembling or directly to the storage tank. Flanged ball valves with thermometers on flow/return position. Insulation in black EPP g/l. All seals are assured by flat fittings and gaskets.
10 Rhico Solar Pump Stations Maverick VRD-9 6 "F "F P (m H O)7 Wilo ST5/7-6 5 Wilo ST5/6-ECO- Pump characteristics (max. speed) - Pressure loss 68, , P (kpa) 9, 9,,5 6 l/min 9, G½" 9, Q (l/h) P (m H O) 7 68,6 Wilo ST5/ P (kpa) 5 Wilo ST5/6-ECO- 9, "F "F 9, 9, 9 5 l/min 5 l/min 9,6 9,8 Controller, flexible tube and expansion tank wall support bracket are supplied separately. See "Solar station accessories" Q (l/h) DN 5 MAVERICK VRD-9 (without controller) FLOW RATE REGULATOR,5 6 l/min without pump 975 with Wilo ST 5/6-ECO- 975 with Wilo ST 5/7-975 FLOW RATE REGULATOR 5 l/min without pump 976 with Wilo ST 5/6-ECO- 976 with Wilo ST 5/7-976 FLOW RATE REGULATOR 5 l/min without pump 977 with Wilo ST 5/6-ECO- 977 with Wilo ST 5/7-977 Pumps supplied with cable in accordance with the norm L=,5 m. Components Flow rate regulator Flow ball valve DN 5 V Return ball valve DN 5 VRRS with check valve Flow pipe with integral degasser Red handle Blue handle Thermometer Nuts Safety unit with - bar manometer, 6 bar safety valve, connection to the expansion tank Wall support bracket Gaskets Insulation Return pump Universal prop for controller n TECHNICAL DATA Check valve opening: 5 mm HO Nominal diameter: DN - ¼" Pressure max.: 8 bar Max temperature: C Ball valve material: MS 58 / brass Check valve material: NORYL Insulation material: EPP schwarz/black g/l Gaskets material: Viton-Centellen Connections: ¼" F Station height: 6 mm Insulation dimensions: 6x5x8 mm 5 mm HO DN - ¼" 8 bar C MS 58 / brass NORYL EPP schwarz/black g/l Viton-Centellen ¼" F 6 mm 6x5x8 mm
11 Rhico Solar Pump Stations Big Maverick VR-9 5 Possibility to install several different controllers. BIG MAVERICK VR-9 is a forced circulation solar station with adjustable flow rate from l/min to 7 l/min. Available with different combinations of electronic management and flow rate regulation. The possibility to assemble different types of flow rate regulators makes it a versatile system to satisfy small and large plants, while the controller allows us to manage up to 5 different types of plant, and comes equipped with pictogram display. BIG MAVERICK VR-9 can directly be installed on the wall or on a solar tank through fixing bracket. MAIN CHARACTERISTICS Working range flow rate regulator: 7 l/min. Insulation to protect the controller. Filling/draining/flushing of the system and disassembling of the pump without having to empty the system. Available flow-return and return version. Compact safety unit includes safety valve, manometer and connection with flexible tube for expansion tank; Lateral hole for heat sinking pump. Assembling on the wall or on the storage tank. Flanged ball valves with thermometers on flow/return position. Insulation in black EPP g/l. All seals are assured by flat fittings and gaskets.
12 6 C 8 5 bar 6 C bar 6 C Rhico Solar Pump Stations Big Maverick VR-9 6 ¼"F P (m H O) Pump characteristics (max. speed) - Pressure loss Wilo-TOP-S / 7,6 7,8 98, P (kpa) 6 ¼"F , 78, 7 68,6 6 Grundfos UPS -8 58,8 5 Wilo Star RS /8-9, 6 9, 5 VR-9 9, 9,6 9, Q (l/h) ¼"F 9 ¼"F Controller, flexible tube and expansion tank wall support bracket are supplied separately. See "Solar station accessories" DN BIG MAVERICK VR-9 ( without controller) without pump with Wilo Star RS /8- with Wilo TOP-S / with Grundfos UPS -8 Pumps supplied without cable. Code Components n Flow rate regulator 7 l/min Flow ball valve DN V Return ball valve DN VRRS with check valve and ½" M fill/drain/flush valve Flow pipe Red handle Blue handle Thermometer Nuts Safety unit with - bar manometer, 6 bar safety valve, connection to expansion tank, ½" M fill/drain/flush valve Wall support bracket Gaskets Insulation Pump on the return side Universal prop for controller TECHNICAL DATA Check valve opening: 5 mm HO Nominal diameter: DN - ¼" Pressure max.: 8 bar Max temperature: C Ball valve material: MS 58 / brass Check valve material: NORYL Insulation material: EPP schwarz/black g/l Gaskets material: Viton-Centellen Connections: ¼" F Station height: 6 mm Insulation dimensions: 6x5x8 mm 5 mm HO DN - ¼" 8 bar C MS 58 / brass NORYL EPP schwarz/black g/l Viton-Centellen ¼" F 6 mm 6x5x8 mm
13 Rhico Controllers TR sc Controller Solar Thermal Controller Product Code: ST-SC-6 7 The Rhico TR sc solar thermal controller is used for monitoring and controlling solar thermal systems with a single collector array and one cylinder / buffer tank. An animated graphic display visualizes the operational status of the system and the pictograms help make the controller easy to operate. The controller also has monitoring and safety functions to ensure safe operation of the entire system. The extra additional functions of the Rhico TR sc also include a maximum cylinder / buffer temperature, vacuum tube collector function, anti-freeze function, holiday and cylinder / buffer cool function as well as a choice of temperature indications in either degrees Celsius ( C) or Fahrenheit ( F). The safety of the system is supported by a fault diagnosis program. The LCD back light ensures quick and safe attention to occurring errors. Example of application PRODUCT FEATURES Compact unit Electronic pump speed control Maximum cylinder / buffer tank temperature Safety through fault diagnosis Data logging of min. and max. temperatures Temperature display C / F Collector over temperature function Hours-of-operation data logger Tank target temperature Easy installation DISPLAY LCD display with back lighting Animated system operating states OPERATION Menu navigation Side switch for manual, auto, off FUNCTION Holiday (storage tank recooling) Interval / tube collector Anti-freeze Display storage tank top
14 Rhico Controllers TR 6mc Controller Solar Thermal Controller 8 Product Code: ST-SC-6 The Rhico TR 6mc solar thermal controller stores the systems operational data on a SD card. The pre-programmed control boasts systems and extra additional functions allowing control over primary and secondary heat sources. The large display shows the desired systems circuits and allows you to view the operating status of each. The Rhico TR6mc has six inputs for recording temperatures or pulse values, as well as an extra Grundfos Direct Sensors for combined temperature and flow rate measurement. Pumps and switching valves are controlled using three outputs, which can be speed controlled. FUNCTION Example of application Data logger SD card. Reduction of stagnation phases. Holiday (storage tank recooling). Circulation (controlled by temperature / time / pulse). Back-up heating boiler. Solid fuel boiler. Storage tank quick charge. Bypass. Thermostat. Differential thermostat. Timer. Interval / tube collector. Anti-freeze. Anti-legionella cyclical storage tank heating. Display storage tank BMS Alarm output. Two loading zones. PRODUCT FEATURES Compact, Electronic speed control. safety fault diagnosis. Hours-of-operation logger. Software update possible. Storage tank target temperature Seasonal systems (loading of pool / storage tank according to the time of the year). Daily pump start. Modular extensions are possible with heating circuit controllers and expansion modules. Easy installation. DISPLAY OPERATION LCD display with back lighting Animated system operating states Menu navigation Side switch for manual, auto, off
Product range Solex Technical data and dimensioning. 5 Years
Qualität made in Germany Product range Solex Technical data and dimensioning Quality made in Germany 5 Years Handwerkergarantie m anufacturer s warranty Product range Solex Dimensioning High-Flow system
More informationProduct Catalog Evacuated tube collectors CPC OEM CPC w OEM
Product Catalog 2004 Evacuated tube collectors CPC OEM CPC w OEM Table of Contents Development/design Production Outgoing goods warehouse Table of Contents Page Evacuated tube collectors CPC 6 OEM, CPC
More informationDS Series Solar System
DS Series Solar System Permit information Consol 30-58-1800 Collector Flat mount on Colorsteel Plumdeck roofing Valve vent, Open loop http:// www.consolsolar.co.nz 21 Page 1 of This system is an evacuated
More informationInstallation instruction
1 Safety Before installing the device, please read this manual carefully. Please note that the installation must be executed according to relevant technical rules. The installation must also be adapted
More informationKS Pump Stations. Engineering Submittal Sheet. Installation Sets for Collectors
Engineering Submittal Sheet Installation Sets for Collectors Layout legend S Supply from collector to storage R Return from storage to collector 1 Ball valve with thermometer and integrated gravity break
More informationPump group DN 32 SA, SMT. Mounting and operating instruction
Pump group DN SA, SMT Mounting and operating instruction WOMIX ul. Sportowa 1 89-00 Szubin, Poland phone/fax +8 8 0, +8 8 1 www.womix.com.pl e-mail: export@womix.com.pl Pump group DN Insulation pump group
More informationNon-Imaging Concentrator based Solar System Operations & Maintenance Manual
Non-Imaging Concentrator based Solar System Operations & Maintenance Manual UNDP-GEF Project on Concentrated Solar Heat Ministry of New & Renewable Energy Government of India November, 2014 Prepared By:
More informationFact Sheet Sky CPC 58
Principle: The CPC 58 solar vacuum tube collector is composed of a series of borosilicate glass pipes with double air gap, welded at the end, inside which a vacuum is closed. The internal air gap is made
More informationVICTRIX PRO Wall-hung modular condensing boiler for heating only
PRO Wall-hung modular condensing boiler for heating only Wide range (5 models) High efficiency and low pollutant emissions thanks to condensing technology Modulating heat output from 10 to 100% Possible
More informationPump Stations for Heating Circuits
Pump Stations for Heating Circuits circulation pumps pump stations manifolds Regulus spol. s r.o., Czech Republic Do Koutů 897/, Praha Tel.: + 7 9, Fax: + 7 97 E-mail: sales@regulus.eu Web: www.regulus.eu
More informationBarilla Solar Ltd. Product Brochure. Barilla Solar Lmt Unit 2, Dell Buildings Milford Road Lymington SO41 0ED T:
2014 Barilla Solar Ltd Product Brochure Barilla Solar Lmt Unit 2, Dell Buildings Milford Road Lymington SO41 0ED T: 01590 671 997 www.barillasolar.co.uk Flat Plates & Mounting Systems Barilla F22AR Solar
More informationSOLAR THERMAL Forced circulation solar thermal system with selective flat plate collectors SELECTIVE SLIM
Forced circulation solar thermal system with selective flat plate collectors SEETIVE SIM SEETIVE 2.0 V flat plate collector vertical arrangement SEETIVE 2.0 O flat plate collector horizontal arrangement
More informationDISTRIBUTION GROUP WITH THERMOSTATIC REGULATION. Upper connections G1 F Without fittings Fittings with running connection* Without pump
Description This preassembled pump group is part of the arberi trolli HEATING line. This distribution group allows the circulation of the thermal fluid, coming from the primary circuit and it maintains
More informationCOMPONENTS FOR SOLAR THERMAL SYSTEMS
COMPONENTS FOR SOLAR THERMAL SYSTEMS 2012 2 The CALEFFI SOLAR product range has been specially developed for use in solar thermal systems, where high temperatures can normally be reached and where, depending
More informationPump group DN 25 SA, SMTC, SMT. Mounting and operating instruction
Pump group DN SA, SMTC, SMT Mounting and operating instruction WOMIX ul. Sportowa 1 89-00 Szubin, Poland phone/fax +8 8 0, +8 8 1 www.womix.com.pl e-mail: export@womix.com.pl Pump group DN Insulation pump
More informationCatalogue Solar stations DN 20. Solar thermal solutions. Valid for the UK
Catalogue 01 2016 Solar stations DN 20 Solar thermal solutions Valid for the UK Overview product range SolarBloC Solar stations Performance data SolarBloC midi Premium SolarBloC maxi Premium SolarBloC
More informationSolar Thermal. Grant Solar Pump Station Installation & Servicing Instructions
Solar Thermal Grant Solar Pump Station Installation & Servicing Instructions Part No. DOC 96. Rev 02. October 2012 Important Note Important Note for Installers The Pump Station supplied with your Grant
More informationMANUAL. Collector FK7300. Mounting parallel roof bracket attachment system
MANUAL Mounting parallel roof bracket attachment system For horizontal positioning of the collectors, the assembly instructions apply accordingly! Collector FK7300 6 9 0 x x x x / version 2006.12 Contents
More informationSonoMeter 30 Energy Meters
SonoMeter 30 Energy Meters Description MID examination certificate no.: LT-1621-MI004-020 The Danfoss SonoMeter 30 is a range of ultrasonic, compact energy meters intended for measuring energy consumption
More informationSchüco Premium Collectors Outstanding quality, performance and design
Schüco Premium Collectors Outstanding quality, performance and design 2 Schüco Premium collectors Schüco Premium line collectors - The next generation Since its entry into the solar thermal sector, Schüco
More informationValves, controls + systems Valves and controls for solar installations Regusol-180
The Oventrop Quality Management System is certified to DIN-EN-ISO 9001 Application: The Oventrop programme for solar installations allows the connection of the collector to the storage cylinder within
More informationMetering systems 0578EN January 2014 Thermal energy meters, ultrasounds type for use in a boiler room GE552-1 series
Version A Version B GE552-1 Description The GE552-2 meters are thermal energy meters with double register and ultrasound,. They enable the measurement of energy used for heating and air-conditioning. They
More informationCIRCO5SolarCirculationUnit
TECHNICAL INFORMATION / INSTALLATION MANUAL CIRCO5SolarCirculationUnit Wagner& Co CIRCO 5 Solar Circulation Unit the reliable pump station for efficient circulation of the heating fluid in combination
More informationSOLAR AEROLINE. fast simple reliable. The perfect connection technology for solar hot water
SOLAR The perfect connection technology for solar hot water Pipe systems for solar, heating, heat pumps and air-conditioning technology fast simple reliable Assembly options Applications: On-roof, in-roof
More informationEvacuated tube collectors
Evacuated tube collectors Evacuated tube collectors The overall performance of ecological heating systems based on solar thermal energy is significantly dependent on how efficiently the solar collector
More informationPRESSURE CONTROL VALVES SABS 198
PRESSURE CONTROL VALVES SABS 198 1 CALVALVE DOUBLE BLOCK Pressure control combined pressure reducing valve and expansion relief valve, copper by copper compression ends. DZR alloy body. Replaceable cartridge
More informationVZD / VZP and DFM Consumption measurement
CONTOIL VZD / VZP and DFM Consumption measurement Applications Fuel consumption measurement for trucks, buses, trains, construction and agricultural machinery, small boats and generators. Features Quick
More informationSHARKY 775 COMPACT ENERGY METER ULTRASONIC
APPLICATION The ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. FEATURES 4 Approval for ultrasonic meter with dynamic
More informationTemperature differential controller
Temperature differential controller 5 inputs, 2 outputs Installation and operating instructions EN 742.114 Z01 12.17 Subject to change due to technical improvements! Contents 1 General safety instructions...3
More informationK35 HeatBloC with 3-temperature mixing valve
PAW GmbH & Co. KG Böcklerstr. 11, D-31789 Hameln, Germany Phone: +49-5151-9856-0, Fax: +49-5151-9856-98 E-mail: info@paw.eu, Web: www.paw.eu Installation and Operation Instructions K35 HeatBloC with 3-temperature
More informationZone manifold DN 25, DN 32, DN 50. Mounting and operating instructions
Zone manifold DN 25, DN 32, DN 50 Mounting and operating instructions WOMIX Sportowa 31 89-200 Szubin, Poland phone/fax +48 52 382 44 50, +48 52 382 44 51 www.womix.com.pl e-mail: export@womix.com.pl Central
More informationFloor heating manifold with automatic flow control
dynacon Floor heating manifold with automatic flow control Pressurisation & Water Quality Balancing & Control Thermostatic Control EnGInEERInG advantage dynacon adjusts the flow rate in the individual
More informationSonoMeter 30 Energy Meters
SonoMeter 30 Energy Meters Description The Danfoss SonoMeter 30 is a range of ultrasonic, compact energy meters intended for measuring energy consumption in heating and cooling applications for billing
More informationGASOKOL vacutube. GASOKOL GmbH, vacutube_de 1 von 5
Principle: Because of the warming up the fluid into the absorber pipe converts into steam, the vacuum into the circuit supports this process. The steam rises by its own incentive. The fluid liquefies into
More informationHYDRUS ULTRASONIC METER
APPLICATION Static ultrasonic water meter for accurate measuring and recording for all applications of water supply. FEATURES 4 Real data communication, open metering telegram 4 Long-term stability under
More informationPowertech/Apricus TM AP Solar Collector Specifications
Powertech/Apricus TM AP Solar Collector Specifications Via a Powertech Thermal Store, this new home in Salisbury also uses the 88 tube solar energy array (two on the east side) to heat the pool once the
More informationPRODUCTS FOR HEATING AND TAP WATER SYSTEMS. Product Catalogue
PRODUCTS FOR HEATING AND TAP WATER SYSTEMS Product Catalogue Table of Contents LK Armatur - A One-Stop Supplier...5 LK 811 ThermoMat - Simple and precise... 8 Loading Units... 9 LK 810 ThermoMat 2.0 G
More informationDynacon. Floor Heating Manifolds Floor heating manifold with automatic flow control
Dynacon Automatic Flow Control Floor Heating Manifolds Floor heating manifold with automatic flow control IMI HEIMEIER / Floor Heating Control / Dynacon Dynacon Dynacon adjusts the flow rate in the individual
More informationManual CPK 7210 N. Flate plate collector. Mounting parallel bench srew mountingsystem x x x x / version
Manual Mounting parallel bench srew mountingsystem Flate plate collector CPK 7210 N 6 9 0 x x x x / version 2008.03 Contents Safety information...3 Transport note...4 Assembly instructions - Collector...5
More informationCOMPONENTS FOR SOLAR THERMAL SYSTEMS
COMPONENTS FOR SOLAR THERMAL SYSTEMS The Caleffi Solar product range has been specially developed for use in solar thermal systems, where high temperatures can normally be reached and where, depending
More informationHYDRUS ULTRASONIC METER
HYDRUS APPLICATION Static ultrasonic water meter for accurate measuring and recording for all applications of water supply. FEATURES 4 Ultrasonic water meter with long-term stability under difficult conditions
More informationAV 23 Balancing valves SETTER Inline
AV Balancing valves SETTER Inline Application Direct reading and balancing valve with visual flow indication. Correct balancing of circuits ensure optimum efficiency of the system and can therefore help
More informationCEGA SYSTEMS BY GREGGERSEN
CEGA SYSTEMS BY GREGGERSEN PRODUCT CATALOG SWITCHOVER SYSTEMS SWITCHOVER SYSTEMS MediControl switchover system INTRODUCTION Overview APPLICATION EXAMPLES Care and caution are advised when handling compressed
More informationSolar Collector Product Specifications
Solar Collector Product Specifications AP-10 / AP-22 / AP-30 Overall Dimensions Model AP-10 AP-22 AP-30 Number of tubes 10 22 30 Overall Length (inches) 78 78 78 Overall Width (inches) 31.3 67.5 86.4 Overall
More informationLAUDA Integral. Process thermostats for professional external thermostating across a wide temperature range from -90 up to 320 C
LAUDA Integral Process thermostats for professional external thermostating across a wide temperature range from -9 up to C Application examples Process technology Process engineering Production Research
More informationComponents for central heating
01 01 Components for central heating Booster units and spare parts 18 Hydraulic separator and spare parts 21 Dirt separators - Deaerators 23 By-Pass differential valve - Air separator units 32 Filling
More informationHERZ PUMPFIX HERZ PUMPFIX. Datasheet 1 45XX XX, Issue Table of contents. Page 1. General information about HERZ PUMPFIX pump groups...
Datasheet 1 45XX XX, Issue 0216 Table of contents General information about pump groups...2 Direct (1 4510 XX)...4 DN 20 DN 25 DN 32 Mix (1 4511 XX)...6 DN 20 DN 25 DN 32 Mix with bypass (1 4511 XX)...10
More informationenviko solar product brochure
enviko solar product brochure commercial & residential applications www.enviko.com Solar Thermal Evacuated Tube Collectors Top of the range, maximum efficiency solar evacuated tubes. Features These new
More informationBoost-A-Break - Break Tank & Booster Sets
Boost-A-Break - Break Tank & Booster Sets BTAB Fixed and Variable Speeds Overview Datasheet Page 1 of 9 Overview Break Tank assembly with Fluid Category 5 protection by virtue of the integral Type AB air
More informationU Q He y ys. UniPlate. Solar Collectors
U Q He y ys UniPlate Solar Collectors Solar Collector UNIPLATE MODEL - SOLAR COLLECTOR Full plate high performance absorber High transmission tempered safety glass Optimal insulation Aluminium casing Easy
More informationInstallation and Operation Instructions HeatBloC K31 - DN 25
PAW GmbH & Co. KG Böcklerstr. 11, D-31789 Hameln Phone: +49-5151-9856-0, Fax: +49-5151-9856-98 E-mail: info@paw.eu, Web: www.paw.eu Installation and Operation Instructions HeatBloC K31 - DN 25 2015/03
More informationSOLAR HEATING SYSTEM
SECTION 13600 SOLAR HEATING SYSTEM PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 07600 - Flashing and Sheet Metal. 2. 07900 - Joint Sealers. 3. 15260 - Thermal Insulation (Plumbing). 4. 15410 - Piping
More informationLK Manifold Shunt VS2
LK Manifold Shunt VS2 Design LK Manifold Shunt VS2 is a shunt unit with a two way control valve used in systems with a primary pump. The shunt unit is mountable from both the left and right of LK Manifolds.
More informationThe next generation of controllers and valves
The next generation of controllers and valves Vexve - The next generation of controllers and valves When you want to ensure the heating in your home is energy-efficient, it is crucial to find the right
More informationHeat pumps for swimming pools
Heat pumps for swimming pools Full range of heat pumps for indoor and outdoor swimming i pools The best heating for your pool Reliable and effective Made in Europe www.certikinpoolsindia.net THE CHALLENGE:
More informationIsoTherm FlowGuards Mini Ball Valves Gauges Aquastats Unions
82 IsoTherm FlowGuards Mini Ball Valves Gauges Aquastats Unions 83 Adjustment knob (sets supply temperature) Mixing Valve 1 Male BSP Threads Mixing Point Supply Inlet from Boiler Temperature Gauge (indicates
More informationSBS Manual for the specialised craftsman. Filling and flushing station. Connection Operation. en Manual
SBS 2000 Filling and flushing station Manual for the specialised craftsman Connection Operation Thank you for buying this RESOL product. Please read this manual carefully to get the best performance from
More informationCross Flow Heat Exchanger H352
Cross Flow Heat Exchanger H352 H352 Cross Flow Heat Exchanger Shown With Optional Plain Tube of H352A fitted. Allows Investigation Of Plain And Finned Cross Flow Heat Exchangers. Expandable Free & Forced
More informationMANIFOLDS AND DISTRIBUTION EQUIPMENT
MANIFOLDS AND DISTRIBUTION EQUIPMENT - Radiators distribution equipment... 52 - Components for radiators... 57 - Underfloor heating/cooling distribution equipment... 58 - Modular manifolds... 60 - Components
More informationTECHNICAL CHARACTERISTICS: Structure : upright type, realized in sheet steel epoxy coated white colour both in- and outside or in stainless steel
TECHNICAL CHARACTERISTICS: Structure : upright type, realized in sheet steel epoxy coated white colour both in- and outside or in stainless steel 18/10 AISI 304 both in- and outside. All the internal corners
More informationInstallation and Operation Instructions K38 HeatBloC - DN 32
PAW GmbH & Co. KG Böcklerstr. 11, D-31789 Hameln, Germany Phone: +49-5151-9856-0, Fax: +49-5151-9856-98 E-mail: info@paw.eu, Web: www.paw.eu Installation and Operation Instructions K38 HeatBloC - DN 32
More informationECONOPLATE BV SERIES HOT WATER SERVICE PACKAGED HEAT EXCHANGERS WITH THERMAL STORES
ECONOPLATE BV SERIES HOT WATER SERVICE PACKAGED HEAT EXCHANGERS WITH THERMAL STORES TECHNICAL AND INSTALLATION DOCUMENTATION STOKVIS ENERGY SYSTEMS UNIT 34 CENTRAL PARK ESTATE 34 CENTRAL PARK ESTATE WEST
More informationInstallation and Operation Manual for a Solar System with KPW Collectors
Installation and Operation Manual for a Solar System with KPW Collectors EN v. 1.0 CONTENTS General Installation and Operation Instructions... 3 Collector Technical Data....... 4 1 Delivery of Mounting
More informationCORONA E ELECTRONIC METER MULTI-JET
APPLICATION Fully electronic compact water meter with impeller scanning for recording volume. Highly accurate recording of all billing data at medium temperatures up to 90 C. FEATURES 4 Electronic sensor
More informationPRODUCT CATALOGUE SOLAR THERMAL ENERGY
PRODUCT CATALOGUE SOLAR THERMAL ENERGY 1 solar energy SOLAR ENERGY, STAR ENERGY Why solar energy? The high price of energy, an increasingly widespread environmental awareness, new legislation on energy
More informationINSTALLATION AND COMMISSIONING MANUAL CONTENTS. Function. Important Product range Technical specifications
28237 www.caleffi.com Circulation units for solar thermal systems Copyright 204 Caleffi 278-279 series INSTALLATION AND COMMISSIONING MANUAL CONTENTS Function Important Product range Technical specifications
More informationInstallation and Commissioning Instructions High Temperature Zone Module F31-1" (DN 25)
PAW GmbH & Co. KG Böcklerstr. 11, D-31789 Hameln, Germany Tel.: +49-5151-9856-0, Fax: +49-5151-9856-98 Email: info@paw.eu, Web: www.paw.eu Installation and Commissioning Instructions High Temperature Zone
More informationDifferential Temperature Controller
3 337 Synco 100 Differential emperature Controller R27 Differential temperature controller for solar storage systems. Compact design with two 2-position control output AC 24 230 V. Use Plant types: Solar
More informationPreassembled fixed-point control, distribution and pumping unit for radiant panel heating systems DOMORADIANT Series
95-0055-UK-Rev1.qxd 4-09-2007 10:31 Pagina 1 Preassembled fixed-point control, distribution and pumping unit for radiant panel heating systems DOMORADIANT Series Main features DOMORADIANT, is a preassembled
More informationTechnical Product Submittal
1. General Specifications 1.01 Certifications 1) SRCC OG-100 Technical Product Submittal Oventrop evacuated tube solar thermal collector OVSOL 5-8, 8 tube collector and OVSOL 5-16, 16 tube collector SRCC
More informationdynacon floor heating manifold with automatic flow control
dynacon floor heating manifold with automatic flow control Pressurisation & Water Quality Balancing & Control Thermostatic Control EnGInEERInG advantage Dynacon Description HEIMEIER Dynacon floor heating
More informationhydro unit booster systems
hydro unit booster systems dp pumps technical data INDEX In general 01 Features 04 Controls DPC, MC 06 Controls HU1, MCF, MCJ 07 Controls Pico, Palm 08 Model key 09 Technical data Eco Hydro 10 HU1 11 HU2/3
More informationOPERATION AND INSTALLATION
OPERATION AND INSTALLATION RESIDENTIAL SOLAR PUMP STATION» SE FLOWSTAR PUMP STATION Table of Contents 1 For your safety 1.1 About this manual 1.2 Designated use 1.3 Qualification of the installer 1.4 Hand-over
More informationSUNRAIN SOLAR HEAT PIPE COLLECTOR TZ58/1800- R SERIES
SUNRAIN SOLAR HEAT PIPE COLLECTOR TZ58/1800- R SERIES Welcome to the SUNRAIN Vaccum Tube Solar Collector! Vacuum tube solar collectors are amongst the most efficient and most costly types of solar collectors.
More informationLSC500S3. Powered by Cummins 50HZ. Water-cooled. Three Phase. Diesel KVA 500 KW 400. Standby Power
LSC500S3 Powered by Cummins 50HZ Water-cooled Three Phase Diesel Model LSC500S3 Standby Power KVA 500 KW 400 Prime Power KVA 450 KW 360 Frequency Hz 50 Voltage V 230/400 Rated speed rpm 1500 Cummins has
More informationPent-A-Boost Compact Domestic Booster Sets
Pent-A-Boost Compact Domestic Booster Sets Model BTAF With Integral Automatic Bypass Valve - Overview Datasheet Page 1 of 8 Overview Compact booster pump set designed to boost pressure for tall buildings
More informationAutomatic filter AF 113 G
Automatic filter AF 113 G Cast design with internal pressure cleaning and integrated cyclone effect Connection sizes: G2, screw in flange DN 50 and DN 65 1 Short description MAHLE automatic backflush filters
More informationCompact Static Heat Meter of High-Tech Composite
Compact Static Heat Meter of High-Tech Composite Application The Superstatic 789 is a lightweight and robust compact heat meter consisting of a high-tech composite flow meter, a detachable integrator with
More informationtechnical catalogue tetris KW Chiller and heat pumps air/water
technical catalogue tetris 110 930 KW Chiller and heat pumps air/water > TETRIS Water chiller > TETRIS /HP Reversible heat pump > TETRIS /ST Water chiller with storage tank and pumps > TETRIS /DC Unit
More informationINSTALLATION AND COMMISSIONING MANUAL CONTENTS. Function. Product range. Technical specifications. Characteristic components
7EN www.caleffi.com Circulation units for solar thermal systems Copyright Caleffi 7HE - 79HE series INSTALLATION AND COMMISSIONING MANUAL CONTENTS Function Product range Technical specifications Characteristic
More informationHeating oven with mechanical control
ED series 23 Drying ovens / Heating ovens Heating oven with mechanical control The strength of the BINDER ED series heating oven: routine drying and sterilization applications up to 300 C. Thanks to the
More informationInstallation and Operation Manual for a Solar System with KPC1-BP Collectors
Installation and Operation Manual for a Solar System with KPC1-BP Collectors EN v. 1.3 CONTENTS General Installation and Operation Instructions... 3 Collector Technical Data....... 4 1 Delivery of Mounting
More informationBASTONE (dual) fancoil Units
BASTONE (dual) fancoil Units Technical information manual Western Airconditioning B.V. Tel. +31 (0) 33 247 78 00 www.western.nl 1-INTRODUCTION..3 2- WORKING CONDITION LIMITS...3 3- COANDA EFFECT 3 4- KEY
More informationthree-way mixing valve
three-way mixing valve with or without presetting, for heating and cooling systems. Pressurisation & Water Quality alancing & Control Thermostatic Control engineering avantage Three-way mixing valve, with
More informationThe ecohouse evacuated solar collector
The ecohouse evacuated solar collector all weather...all year round Technology The Solar Tube The Reflector The Solar Collector How It Works Special Features Reasons To Choose Call free now and speak with
More informationIndustrial Diesel Generator Set KD3300-F 50 Hz Fuel Consumption Optimized
RATINGS 400 V - 50 Hz Standby kva 3300 KWe 2640 Prime kva 3000 KWe 2400 Benefits & features premium quality provides one source responsibility for the generating system and accessories The generator set,
More informationHERZ-Motorised flow controler
HERZ-Motorised flow controler Control and regulating valve Data sheet 4006 SMART, Issue 0516 Dimensions in mm 4006 M 4006 R M R Order number DN G L L1 B B1 H without Actuator H with Actuator H1 1 4006
More informationfor Solar Systems with KTU R Collectors
Installation and Operation Manual for Solar Systems with KTU R Collectors EN v. 1.7 CONTENTS General Installation and Operation Instructions... 3 Collector Technical Data... 4 1. Mounting System Delivery...
More informationCIRCULATION PUMPS FOR HEATING SYSTEMS AND AIR-CONDITIONING SYSTEMS VORTEX HEATING PUMPS
VORTEX HEATING PUMPS FOR HEATING SYSTEMS AND AIR-CONDITIONING SYSTEMS 90 C 80 C 70 C 60 C 50 C 40 C 30 C 20 C Pumps Technical structure Technical data Fitting kits Replacement overview 2 TECHNICAL STRUCTURE
More informationFluidic Oscillation Compact Heat Meter
Fluidic Oscillation Compact Heat Meter Application The Superstatic 749 is an autonomous compact thermal energy meter consisting of a flow meter a detachable integrator with a wide range of communications
More informationInstallation and Operation Instructions K31 HeatBloC - DN 50
PAW GmbH & Co. KG Böcklerstr. 11, 31789 Hameln, Germany Phone: +49-5151-9856-0, Fax: +49-5151-9856-98 Email: info@paw.eu, Web: www.paw.eu Installation and Operation Instructions K31 HeatBloC - DN 50 2013/05
More informationELIOS 25 DIGITAL CONTROL UNIT WITH LCD DISPLAY FOR THERMAL SOLAR SYSTEMS TDS 006 M00 0SE A
ELIOS 25 DIGITAL CONTROL UNIT WITH LCD DISPLAY FOR THERMAL SOLAR SYSTEMS TDS 006 M00 0SE 012945A0 040906 1 MAIN FEATURES Power supply 230V~ ±10% 50Hz Backlit alphanumeric LCD display Management of 5 output
More informationDESCRIPTION 9.4 G 3/4"M
DESCRIPTION Six-way ballvalve for HVAC 4 pipes applications to automatically carry out the winter-summer change-over or, potentially, to manage radiant ceilings, fan coils and chilled beams. DIMENSIONS
More informationAir Master BCP. Pool air handling units. Optimized energy consumption Electronic control. Description. Principle schemes
Cooling capacity: Heating capacity: 92,1 to 179,9 kw 69, to 148,7 kw Heating and dehumidification of covered pools Optimized energy consumption Electronic control Description Principle schemes The range
More informationLSE kw. Outdoor packaged unit. Air/water chillers and heat pumps LSE PLUS
Air/water chillers and heat pumps LSE Outdoor packaged unit LSE 60-00 kw Multi-scroll solutions for reliability and high efficiency at partial loads Scroll compressor PLUS R-0A R-0A refrigerant Cooling
More informationTrailer Systems (Gas, Water,& Electric) System View Point
Trailer Systems (Gas, Water,& Electric) Presented At The WBCCI International, Sedalia 2012 Page 1 Look at System View Point Use, Source, Storage, Distribution, Use, Waste Consider Safety System Configuration
More informationRVD120 RVD G2510. Installation. Place of installation. Electrical installation. Permissible cable lengths
en Installation Instructions District heating and d.h.w. controller 74 39 68 G25 RVD2 RVD4 Keep these instructions with the controller! Installation Place of installation In a dry room, e.g. the heat exchanger
More informationCBU144. Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717. Product specification sheet
CBU144 Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717 Product specification sheet Version The Compact Booster Unit consists of the following modules, that
More informationComposite PEX-AL-PEX Tubing
04/01/11 page 1.1 Composite PEX-AL-PEX Tubing List Per Foot 40190F ½ Composite Tubing x 200.62 40190 ½ Composite Tubing x 250.62 40190A ½ Composite Tubing x 300.62 40190B ½ Composite Tubing x 1000.62 40192
More informationBALL VALVES FILTERS TEST POINTS 8
BALL VALVES FILTERS TEST POINTS 8 8 PRODUCT CATALOGUE 357 HYDROSCAND BALL VALVES, FILTERS TEST POINTS TABLE OF CONTENTS BALL VALVES PAGE BALL VALVES The ball valves are mainly used as shut-down valves