Blohm + Voss Pipe Handling Equipment VES-CL Center Latch Elevator, Manual Operated c/w Bushing Technical Documentation Original Instructions
|
|
- Amos Oliver
- 5 years ago
- Views:
Transcription
1 Blohm + Voss Pipe Handling Equipment VES-CL Center Latch Elevator, Manual Operated c/w Bushing Technical Documentation Original Instructions Manual PN Y-D Rev 003 February 2012 Blohm + Voss Oil Tools 1
2 GENERAL INFORMATION Warnings and Note WARNING: A warning indicates a definite risk of equipment damage or danger to personnel. Failure to observe and follow proper procedures could result in serious or fatal injury to personnel, significant property loss, or significant equipment damage. NOTE: A note indicates that additional information is provided about the current topics. WARNING: This technical documentation contains instructions on safety, installation, operation and maintenance for the Blohm + Voss Oil Tools tool. It must be studied before working with the tool. Improper / Unsafe Use The tool must only be used for the designated purpose. When using the tool, the rated load must never be exceeded. Intended use of this manual This manual is intended for use by field service, engineering, installation, operation, and repair personnel. Every effort has been made to ensure the accuracy of the information contained herein. Blohm + Voss Oil Tools, will not be held liable for errors in this material, or for consequences arising from misuse of this material. Anyone using service procedures or tools, whether or not recommended by Blohm + Voss Oil Tools, must be thoroughly satisfied that neither personal safety nor equipment safety will be jeopardized. Intellectual property All rights retained. No part of this document may be reproduced in any form (print, photocopy, microfilm or any other procedure) or be processed using an electronic system without written approval of Blohm + Voss Oil Tools. All information contained in this manual is based upon the latest product information available at any time of printing. Dependent on ongoing technical improvements (ISO 9001) Blohm + Voss Oil Tools reserves the right to change the design and specifications without announcement. The values specified in this manual represent the nominal values of a unit produced in series. Slight deviations in the case of the individual devices are possible. NOTE: In the event of problems that cannot be solved with the aid of this manual, please contact one of the addresses listed below. CE Marking The tool complies with the Machinery Directive 98/37/EC and 2006/42/EC For machines containing any hydraulic or pneumatic powered parts, the Directive 94/9/EC Equipment and protective systems in potentially explosive atmospheres applies. The marking is as follows: CE Ex II 2G T5 (hydraulic tools) or CE Ex II 2G T6 (pneumatic tools). Limited Warranty The warranty provided will be void if the tool is either: 1. Repaired or serviced by a service facility which was not authorised by Blohm + Voss Oil Tools. 2. Replacement parts not manufactured by Blohm + Voss Oil Tools are used. 3. Modifications were made to the tool which were not approved by Blohm + Voss Oil Tools. Manufacturer & Agents World wide Blohm + Voss Oil Tools Hermann-Blohm-Straße Hamburg Germany Phone: / /1162 Fax: / oiltools@blohmvoss.com Blohm + Voss Oil Tools, LLC 7670 Woodway, Suite 266 Houston, Texas United States of America Phone: Fax: bvot@blohmvoss.com Premier Sea & Land Pte. Ltd. 1, Scotts Road #19-12 Shaw Centre Singapore Republic of Singapore Phone: Fax: enquiries@mtqpremier.com.sg 2
3 General safety issues VES elevators WARNING: One should avoid creating ignition sources, like heat, as a result of the use of the tool with other tools or equipment. WARNING: Do not use the tool for any other purpose than given in this document within it`s specification. WARNING: Failure to conduct routine maintenance could result in equipment damage or injury to personnel. WARNING: Wear personal protection equipment while working with the equipment. WARNING: If any safety elements (like safety ropes, safety sheets, plates or washers) were disassembled due to maintenance work, do NOT re-use them. Always replace them with new safety elements. WARNING: It is not allowed to use any components which are of "non-b+v" origine, or use "non-oem" parts which are not approved by B+V. It will void any warranty and may effect the correct functioning of the tool and it's safety features. WARNING: The company operating the tool is responsible for evaluating safe and proper use of the tool in a hazard analysis. WARNING: The operating company is obligated to issue working instructions for safe use and supervise observance of these working instructions. WARNING: Every Employee, which operates, services, inspects or otherwise involved with the use of the tool in other areas has to ensure, that these actions are done by trained and Safe handling WARNING Handles/grip points are marked by green paint. During operations these grips are the only places the tool can be handled safely. In all NON-green marked places there is a risk for injury. Automatic/ remote operated tools may not have any green painted grippoints. In this case it is not allowed to touch the tool while operating. WARNING: Bushing segments must always be used with the same serial number and pipe size. Even when the bushing size is the same, bushings with different serial numbers must never be used. The elevator must never be used without bushings. WARNING: the elevator must never be used without bushings (exept 18 bore elevator). WARNING: All warning plates, signs and labels attached to the equipment must be observed. The warning plates, signs and labels must be present on the tool. Do not remove the labels. If they are missing, replacing is mandatory. WARNING: Any modification to the tool carried out without the approval of Blohm + Voss Oil Tools will void any warranty. WARNING: Using the tool with damaged or worn parts can create serious incidents. by an Blohm + Voss Oil Tools authorized personnel, and should complete regular courses of training, to ensure proper use as well as safe operation, correct maintainance and inspection. WARNING: If necessary, a reasonable, additional supervisor should be appointed during operation. WARNING: Stay away from the tool during operation. In case it is remote operated it may make movements without warning. Safe gripping points 3
4 Serialnumber Warning Signs Pipe Size Sticker Patent Number PN WARNING: The warning plates, signs and labels must be present on the tool. Do not remove the labels. If they are missing, replacing is mandatory. Serialnumber and Pipe Size Warning sign PN Warning sign PN Warning sign PN Warning sign PN Warning sign PN
5 EC-DECLARATION OF CONFORMITY We, Blohm + Voss Oil Tools Hermann-Blohm-Strasse Hamburg Phone:+49(0) Fax:+49(0) declare that the product VES CL Center Latch Elevator, manuell operated which is the subject of this declaration, is in conformity with the following standard(s) or normative documents 2006/42/EC: Machinery Directive from 31 December DIN EN ISO : Safety of machinery, part 1 and 2 DIN EN ISO : Safety of machinery, Risk assessment Directive 94/9/EC: Devices and protection systems for intended use in explosive areas DIN EN : : Non-electrical equipment for use in potentially explosive atmospheres ISO 13535:2002/API 8C: Petroleum and natural gas industries-drilling and production equipment-hoisting equipment Marking: II 2G T6 5
6 MAINTENANCE & TABLE OF CONTENTS DESCRIPTION COMMISSIONING INSTALLATION OPERATION SIZE COMPONENTS INSPECTION DRAWINGS TABLE OF CONTENTS GENERAL INFORMATION 2 Warnings and Note 2 Intended use of this manual 2 Intellectual property 2 Improper / Unsafe Use 2 Manufacturer & Agents World wide 2 CE Marking 2 Limited Warranty 2 General safety issues 3 Safe handling 3 Safety issues elevator 3 VES elevators 3 WARNING: Bushing segments must always be used with the same serial number and pipe size. Even when the bushing size is the same, bushings with different serial numbers must never be used. The elevator must never be used without bushings. 3 Warning Signs 4 EC-DECLARATION OF CONFORMITY 5 TABLE OF CONTENTS 6 1. DESCRIPTION 10 General 10 Intend of use 10 Main assembly 10 Assembly VES-CL Elevator 10 Bushing system 10 Available Pipe Size Range (Bushing System) 11 Improper / Unsafe Use 11 Identification 11 Technical Data 11 Elevator Dimensions 12 Wear Bushing (optional) 13 Intend of Use: 13 Function: COMMISSIONING 16 Commissioning VES-CL Center Latch Elevator 16 Scope of supply 16 Check and Lubrication 16 Function Test INSTALLATION 18 Lifting and transport 18 Installation 18 Installing and removing the required bushing 18 General 18 Removal of the bushings 18 Installation of the bushing 18 Installation Checklist 19 Function test OPERATIONS 22 Safety 22 Operation Running in / Tripping 22 Operation Running out / Tripping MAINTENANCE AND INSPECTION 24 General 24 Lubrication 24 Locking of screws 24 Grease quality 24 Bushing Wear Check 25 Wear of Equipment 25 How to check the bushing the correct way 25 Check of results 25 Minimum ear dimensions 26 Tool Joint Wear Data Drill Pipe 27 Inspection categories acc. to API RP 8B 28 Frequency 28 Periodic inspection 28 Non-periodic inspection 28 Inspection 28 Critical Load Inspection 29 Dismantling Inspection 29 Inspection check lists 30 Check Category I (Ongoing observation) 31 Check List Category II (Daily) 31 Check List Category III (every 6 months) 32 Check List Category IV (every year) 32 Wear data criteria 33 Critical Areas 34 Handling, storage and transport 35 Storage 35 Short term storage after use and less then 3 months 35 Long term storage over 3 months 35 Handling 35 Transport 35 Trouble shooting SIZE COMPONENTS 38 P/N BC Bushing 38 DP-Size Bore Code 38 P/N Bushing 38 DP-Size For Drill Collar with Zip Groove 38 Bore Code 38 P/N Bushing 38 For Drill Collar without Zip Groove 39 Tubing 39 Casing 40 6
7 7. DRAWINGS AND SPARE PARTS 42 P/N Y VES-CL 150 Center Latch Elevator 42 Parts list Y 43 P/N Y VES-CL 250 Center Latch Elevator 44 Parts list Y 45 Spare Parts for VES-CL 350 Center Latch Elevator 46 Parts list Y Y VES-CL 500 Center Latch Elevator 48 Parts list Y 49 P/N Y VES-CL 750 Center Latch Elevator 50 Parts list Y 51 P/N Y VES-CL 1000 Center Latch Elevator 52 Parts list Y 53 Wear Bushing 54 Parts list BC 54 Spare Parts 55 Parts list Y-RSP 55 Parts list Y-RSP 56 Parts list Y-RSP 57 Parts list Y-RSP 58 Parts list Y-RSP 59 Parts list Y-RSP 60 INSTALLATION COMMISSIONING DESCRIPTION TABLE OF CONTENTS MAINTENANCE & DRAWINGS SIZE COMPONENTS OPERATION INSPECTION 7
8 8
9 DESCRIPTION DESCRIPTION 9
10 1. DESCRIPTION General DESCRIPTION The Blohm + Voss VES-CL Elevator is designed with strength and safety factors in accordance with API Section 8C - Regulations and will be used for handling long, heavy strings drill pipe. The design of the bushing segments allows the tool to lift tubular, ensuring a safe hold while minimizing the possibility of damage to the pipe. This model is available for hydraulic power operation. Intend of use The elevator is designed to be installed into Elevator links and handle vertical pipes. WARNING The lifting of vertical pipes is to be performed carefully and must be monitored. The picking up of horizontal or tilted pipes is dangerous and not permitted by the manufacturer. WARNING If the operator considers to use the elevator for other operations than the intended use (for example handling of horizontal pipes), it is mandatory to make an additional risk analysis. Main assembly Assembly VES-CL Elevator The Elevator consist of the following main assemblies: 1. Elevator body with latch 2. Bushing system 3. Wear Bushing (optional-not shown-see page 13) 1 2 GREASE DAILY Bushing system Exchangeable bushings allow to run the elevator for different tubular and sizes, see chapter Size Components. 10
11 Improper / Unsafe Use The VES-CL Elevator must only be used for the designated purpose. When using the VES-CL Elevator, the specificated load must never be exceeded (depending on the rating). Identification DESCRIPTION The identification area clearly identifies the Elevator area (manufacturer, type, material, part number, serial number, date of manufacture). It is important to keep this information ready for the purpose of servicing and repair work. Temperature working range ambient Technical Data VES-CL 150 VES-CL 250 VES-CL 350 VES-CL 500 VES-CL 750 VES-CL C to + 80 C* - 4 F to 176 F* Load Capacity 150 sh tons 250 sh tons 350 sh tons 500 sh tons 750 sh tons 1000 sh tons Part number Y Y Y Y Y Y API test load 360 sh tons 558 sh tons 525 sh tons 1000 sh tons 1500 sh tons 2000 sh tons Weight 148 kg 225 kg 425 kg 597 kg kg 2095 kg Size O.D. 2.3/8-5.1/2 2.3/8-5.1/4 2.3/ / / /2-7 Bushings BC BC BC BC BC BC Links 1.3/4-2.3/4 150t-350t * If not otherwise stated in the databook. 2.1/4-2.3/4 250t-500t 2.1/4-3.1/2 250t-500t 3.1/2-4.3/4 500t-750t 3.1/2-4.3/4 750t 5.1/2 1000t Available Pipe Size Range (Bushing System) VES-CL 150 VES-CL 250 VES-CL 350 VES-CL 500 VES-CL 750 VES-CL 1000 Drill Pipe 2.7/ /8-6.5/8 3.1/2-6.5/8 Drill Collars 3.1/2-5.1/4 3.1/2-6.3/4 - Casing 3.1/ /2-7 - Tubing 2.3/8-4.1/2 2.3/8-5.1/2-11
12 Elevator Dimensions DESCRIPTION VES-CL 150 VES-CL 250 VES-CL 350 VES-CL 500 VES-CL 750 VES-CL 1000 Length [mm] A Width [mm] B Height [mm] C [mm] D A C D 2 Grease Daily B 12
13 Wear Bushing (optional) Intend of Use: B+V Wear Bushing for VES-CL-Bushing Elevators are designed for reducing the Wear of the Elevator and only designed for being used with B+V VES-CL Bushing Elevators. Function: The B+V Wear Bushing for Bushing Elevators have to be choosen according to the size of the Bushing and the bore code according to the list below. Before assembling the B+V Wear Bushing to the Elevator check if it is the right one. The P/N on the B+V Wear Bushing has to be checked with the P/N in this manual. For assembling the B+V Wear Bushing, you have to make sure that all parts have to be assembled in the correct order and the screws have to be tightened properly. DESCRIPTION Item 1: Elevator Body machined for Wear Bushing P/N XXXXXX-Y-WB for example: P/N Y-WB (VES-CL 350 Elevator for use with Wear Bushing, Wear Bushing is not included) Item 2: Wear Bushing Assembly P/N BC Bore code Pipe Size WB outside dia. B Wear bushing BC /8 - - BC /2 BC , BC / BC / BC /8 176 BC BC / other sizes on request
14 DESCRIPTION 14
15 COMMISSIONING COMMISSIONING COMMISIONING 15
16 2. COMMISSIONING Commissioning VES-CL Center Latch Elevator Blohm + Voss strongly recommends to accomplish the Elevator commissioning with the Blohm + Voss Commissioning. Read manual before first use! COMMISSIONING OK o Check crew is aware of all danger regarding handling the B + V tool. OK o Go through manual with crew. Prior to use of the Blohm + Voss Elevator following checks must be carried out : Scope of supply OK o Cross check all delivered parts. Check and Lubrication OK o OK o OK o Check elevator is in closed position. Apply grease to all greasing points until grease is visibly coming out of the bores. Check if elevator is installed as outlined in manual. Function Test OK o OK o OK o OK o OK o OK o OK o Check elevator opens. Check required bushings are installed before first use. Check all bushing segments are of same size and serial number. Check if bushings are fixed correctly. Check all safety / lock wire is present. Check elevator closes. Pick up a pipe. 16
17 INSTALLATION INSTALLATION 17
18 3. INSTALLATION Lifting and transport WARNING: Lift the VES-CL Elevator on the lifting ears only. WARNING: Wear your personal protection equipment at all times. Installation INSTALLATION 1. Remove the link block bolts, and allow the link block assembly to swing open. 2. Place the links in the now open elevator ears, and secure the link block by replacing the removed bolts and safety springs. 3. Close and secure the link blocks. 4. Make sure that the size of the bushing compares to the size of the Drill Pipe. Installing and removing the required bushing General A bushing consists of two segments in the elevator body. The body and the latch must be open in order to equip the elevator with the required bushing. Make sure that both bushing segments have the same size and serial number. Removal of the bushings The elevator body must be open. Remove the screws on the top of the elevator. Screw the handles into the bushing segment. Turn the segments for removal. Installation of the bushing Before installing a new bushing, the seating area in the elevator must be cleaned and lubricated. Screw the handles into the bushing segment. Turn the segment into the body. Fixate the segments with the screws on top of the elevator. Install new lock wire to secure the screws. Handling of bushings 18
19 Installation Checklist Basically the elevator has to be installed as shown in the manual. OK o Make sure the required bushings are installed before first use. OK o Make sure the bushings are fixated with the screws & lock wired. Function test OK o Close elevator. OK o Open elevator. OK o Check loose service tools are removed from the elevator. INSTALLATION 19
20 INSTALLATION 20
21 OPERATIONS OPERATIONS 21
22 4. OPERATIONS WARNING: Never open the elevator when the pipe load is still suspended by the elevator. WARNING: Observe the elevator continuously while closing to check if the elevator is properly closed. WARNING: All warning plates, signs and labels attached to the equipment must be observed. WARNING: Do never unlatch/open the elevator while a pipe is suspended in the elevator; the pipe will be lost! WARNING: Using the elevator with damaged or worn parts can create serious incidents. WARNING: The picking up of horizontal or tilted pipes is dangerous. This use is not permitted. Due to the danger it should not be performed by operating personnel. The lifting of vertical pipes is to be performed carefully and must be monitored. WARNING: Any modification to the elevator carried out without the approval of Blohm + Voss will void any warranty. Safety It is recommended to have the VES-CL Elevator operated by the driller. The driller (and or the floor man) must coordinate operation of the elevator and slips/spider so one tool is engaged around the tubular before the other is disengaged. Thus, one or both tools continuously suspend the tubular during all stages of pipe handling operations. Operation Running in / Tripping OPERATIONS 1. The VES-CL elevator is lowered around the tooljoint and elevator is closed. 2. A signal is given to the driller when the VES-CL elevator is closed. 3. The pipe is made up. 4. The driller lifts the VES-CL elevator in order to pick up the load. 5. The slips/spider is commanded to open, simultaneously, the driller picks up the elevator while the driller raises the spider/slips. 6. The driller lowers the string into the hole. 7. The driller sets the spider/slips. 8. Open the VES-CL elevator and pick up a new section of pipe. Operation Running out / Tripping 1. The VES-CL elevator is lowered around the tooljoint and the elevator is closed. 2. Raise the spider/slips. 3. Pull out the string. 4. Close the spider/slips. 5. Release the stringweight from the VES-CL Elevator by lowering it slightly. 6. Now run out the stand or joint. 7. When the pipe is running out, pick up the stand and set it back. 8. Open the VES-CL Elevator and guide pipe out. 9. Lower VES-CL Elevator and pick up the string at rigfloor. 22
23 MAINTENANCE & INSPECTION MAINTENANCE & INSPECTION 23
24 5. MAINTENANCE AND INSPECTION General Lubrication The elevator needs to be lubricated daily on the following points. Use a grease gun: Grease points: 1. The hinge pin. 2. The latch pin. 3. Springs. Locking of screws All screws are normally secured by mechanical bolt lock or with a lock wire. Check daily. Grease quality In order to achieve efficient greasing even at different environmental temperatures, we recommend the following grease types should be used (obtainable from Blohm + Voss Oil Tools): Low-Viscosity grease Type AVIATICON Grease XRF Grease Fitting Alternatively; Use EP1 gear lubricating grease for greasing non-oil tight gear trains when temp. < 0 C/32 F. Use EP2 when temp. > 0 C/32 F. MAINTENANCE & INSPECTION Grease Fitting 24
25 Bushing Wear Check Wear of Equipment Normal wear of bushings and elevator ears caused by usage will eventually reduce the load capacity of elevators. The existence of cracks or the appearance of defects can indicate severe deterioration and even failures. Prompt attention is required either to remove the elevator from service immediately or to undertake appropriate repair. A wear condition in its early stages is common. Frequently, it results in a tool joint sticking to the elevator. Elevators showing hammer marks around the top of the bore should be closely examined to determine whether it is the elevator, the tool joint or both are faulty. To indentify the conditions of the 18 Elevator taper gauges are available for all B + V Elevators (P/N ). A set of gauges consists of an 18 gauge (GOOD) and a 15 gauge (BAD). How to check the bushing the correct way 1. Fit the gauge to the inner bore of the bushing. 2. Push the gauge against the bushing and start to move the gauge downwards until the chamfer touched the 18 shoulder. 3. Check the result as follows: Check of results 1. Using the GOOD gauge: If the gauge sits directly on the bushing without showing any clearance between gauge and bushing, the bushing is OK. 2. If the gauge shows space between the gauge and the bushing, you have to check with the second gauge. 3. Using the BAD 15 gauge: If the gauge shows any clearance between gauge and bushing, the bushing is OK. 4. If the gauge sits directly on the bushing without showing any space between gauge and bushing, take the elevator out of service. WARNING: If the taper is less than 15 take the elevator out of service or exchange the bushing. If the taper is between 18 and 15, reduce the elevators load capacity to 90%. Never use the elevator without a bushing. MAINTENANCE & INSPECTION Gap or no Gap? Blohm+Voss 18 and 15 gauge (P/N ) 25
26 Minimum ear dimensions WARNING: Minimum ear dimensions are only valid when the elevator is in otherwise good condition, does not have excessive wear, cracks or other defects, or previous weld repair and has not been misused. This inspection criteria can not on their own determine the overall condition of the elevator and its suitability for continued use. A Elevator Type dimension A Partnumber Minimum [mm] VES-CL ,1 VES-CL ,1 VES-CL ,8 VES-CL ,8 VES-CL VES-CL Picture: Dimension A MAINTENANCE & INSPECTION 26
27 Tool Joint Wear Data Drill Pipe Check for wear of the Bushing/Elevator by measuring the Center Bore diameter. The maximum wear on the Center Bore is: Nominal size + 0,25 inch. The following table shows the minimum required Tool Joint diameter, depending on the Center Bore and rating of the Elevator. As soon as the Tool Joint diameter falls below the rating line, the Bushing/Elevator or the pipe has to be changed (Contact B + V or a B + V Authorized Repair Center) Minimum required Tool Joint Diamter (inches) MAINTENANCE & INSPECTION tons 750 tons 500 tons 350 tons 250 tons 150 tons 100 tons 1000 tons 750 tons 500 tons 350 tons 250 tons 150 tons 100 tons Actual 5Center Bore 6 (inches) 7 8 Tool Joint Diameter "D" Actual Center Bore "E" 27
28 Inspection categories acc. to API RP 8B MAINTENANCE & INSPECTION Category I This category involves observing the equipment during operation for indications of inadequate performance. When in use, equipment shall be visually inspected on a daily basis for cracks, loose fits or connections, elongation of part, and other signs of wear, corrosion or overloading. Any parts found to show cracks, excessive wear, etc., shall be removed from service for further examination. The equipment shall be visually inspected by a person knowledgeable in that equipment and its function. Category II This is Category I inspection plus further inspection for corrosion, deformation, loose or missing components, deterioration, proper lubrication, visible external cracks, and adjustment. Category II may involve some disassembly to access specific components and to identify wear that exceeds the allowable tolerances. Category III This is Category II inspection plus further inspection, which should include NDT of critical areas and may involve some disassembly to access specific components and to identify wear that exceeds the allowable tolerances. Prior to inspection, all foreign material such as dirt, paint, grease, oil, scale, etc. shall be removed from the concerned parts by a suitable method (e.g. paint-stripping, steam-cleaning, grit-blasting). Category IV This is Category III inspection plus further inspection for which the equipment is disassembled to the extent necessary to conduct NDT of all primary-load-carrying components. Equipment shall be: disassembled in a suitableequipped facility to the extent necessary to permit full inspection of all primary-loadcarrying components and other components that are critical to the equipment. inspected for excessive wear, cracks, flaws and deformation. Procedure: Corrections shall be made in accordance with the manufacturer s recommendations. Prior to inspection, all foreign material such as dirt, paint, grease, oil, scale, etc. shall be removed from the concerned parts by a suitable method (e.g. paintstripping, steam-cleaning, gritblasting) Frequency Periodic inspection The recommended schedule for inspection of all kind of Elevators is as follows: Ongoing: I Daily: II 6 Monthly: III 1 Year: IV The recommended frequencies apply for equipment in use during the specified period. The inspection frequencies are only recommendations. The schedule of inspection heavily depends on the following factors: environment load cycles regulatory requirements operating time testing repairs re manufacture Non-periodic inspection A complete, on-job, shut-down inspection equivalent to the periodical Category III or Category IV should be made before (if anticipated) and after critical jobs (e.g., running heavy casing / drill strings, jarring, pulling on stuck pipes and/or operating at extreme low temperatures) <-20 C (<-4 F). Inspection A thorough inspection should be carried out periodically (every 3 months) or as special circumstances may require. Before starting an inspection disconnect hydraulic/pneumatic system and remove all foreign materials (dirt, paint, grease Oil, scale, etc.) from surface by a suitable method. After a field inspection, it is advisable to record the extent of testing and testing results. Conduct the periodic or critical load inspection in the field by the crew with the supervisor. If cracks, excessive wear etc. is recognized, contact Blohm + Voss Oil Tools or an authorized service company. 28
29 Critical Load Inspection Critical loads may occur. For example: impact loads such as jarring, pulling on stuck pipe, etc. If critical loads occurred unexpectedly, conduct the inspection immediately. Dismantling Inspection Generally, when the equipment returns to base, warehouse, etc. Carry out the Tool inspection, immediately. Furthermore, control it prior to its being sent on the next job. The Tool should be dismantled and inspected in a suitably equipped facility for excessive wear, cracks, flaws or deformations. Corrections should be made in accordance with recommendations which can be obtained from Blohm + Voss Oil Tools. Weldings at the castings should be done only by Blohm + Voss Oil Tools or an authorized service company in according to Blohm + Voss welding procedure. When need is shown in a field inspection, dismantle the Tool and arrange an inspection in a suitably equipped facility. Springs should be carefully visually inspected for excessive wear and obvious weakness. MAINTENANCE & INSPECTION 29
30 Inspection check lists CHECK LIST FRONT PAGE TYPE OF EQUIPMENT SERIAL NUMBER PART NUMBER SUPERVISOR DATE OF INSPECTION INSPECTION CATEGORY PLACE OF INSPECTION MAINTENANCE & INSPECTION 30
31 Check Category I (Ongoing observation) Observe during operation for inadequate performance Check List Category II (Daily) CHECK FOR THE FOLLOWING GENERAL ISSUES (but not limited to): DESCRIPTION CHECKED SIGNATURE 1 Complete front page of check list for the records. OK 2 Check for correct size of elevator bushings. OK 3 Check state of lubrication. OK 4 Check functioning of elevator as a whole. OK Remarks CHECK FOR LOOSE ITEMS, ESPECIALLY FOR (but not limited to): DESCRIPTION CHECKED SIGNATURE 1 Hinge pins, bolts and retainers. OK 2 Fixation of bushing segments. OK 3 Screws, bolts, nuts, washers, retainers, springs and lock wire. OK 4 Link blocks. OK 5 Check presence and condition of warning plates and labels. OK Remarks CHECK FOR CRACKS, ELONGATION, DAMAGE AND CORROSION, ESPECIALLY FOR (but not limited to): DESCRIPTION CHECKED SIGNATURE 1 Elevator Body and Door. OK 2 Hing pins, bolts, nuts. OK 3 Bushing Segments. OK 4 Latch and Lug. OK Remarks MAINTENANCE & INSPECTION SUPERVISOR DATE 31
32 Check List Category III (every 6 months) GENERAL DESCRIPTION CHECKED SIGNATURE 1 Carry out an Category II inspection. OK 2 NDT (MPI) critical areas. Some disassembly may be needed to do so. OK 3 Check parts for wear according to allowable tolerances. OK Remarks Check List Category IV (every year) GENERAL DESCRIPTION CHECKED SIGNATURE 1 Carry out an Category III inspection. OK 2 NDT (MPI) critical areas and load bearing components. Strip elevator to do so. OK Remarks MAINTENANCE & INSPECTION SUPERVISOR DATE 32
33 Wear data criteria Body Hinge Pin (all data in mm) VES-CL 150 VES-CL 250 VES-CL 350 VES-CL 500 VES-CL 750 VES-CL 1000 Dimension dia. new: 54,85 64,85 79,85 89,85 99,85 119,85 Bore dia. new max: 55,08 65,07 80,07 90,07 100,09 120,09 Bore dia. worn max: 55,53 65,52 80,65 90,65 100,67 120,67 Latch Hinge Pin (all data in mm) VES-CL 150 VES-CL 250 VES-CL 350 VES-CL 500 VES-CL 750 VES-CL 1000 Dimension dia. new: 37,85 44,85 54,85 79,85 89,85 119,85 Bore dia. new max: 38,06 45,06 55,07 80,07 90,09 120,09 Bore dia. worn max: 38,51 45,54 55,52 80,65 90,67 120,67 Wear Bushing (all data in mm) VES-CL 150 / VES-CL 1000 Bore code Dimension dia. new a BF BC ,4 99,99 Bore dia. worn max a BF BC , BF BC , BF BC , BF BC , BF BC ,58 a MAINTENANCE & INSPECTION 33
34 Critical Areas Latch Latch area Critical fields throught hatching marked MAINTENANCE & INSPECTION Latch ear and nose Hinge area 34
35 Handling, storage and transport Storage Storage of the tool requires the following measures to be taken: Ensure the tool is protected from water ingress Ensure the tool is stored in such a way, that personnel cannot be wounded by moving parts or sharp edges. If needed, secure the tool with ropes or otherwise in order to protect it from sliding due to ship movements. Short term storage after use and less then 3 months Preserve the tool: Grease all blank surfaces with grease: Cylinders Preserve all other blank surfaces with Amber/Tectyl 846 Spray or equivalent Storage: Store in a dry environment with humidity max 80%. Commissioning: Not needed Long term storage over 3 months Preserve the tool: Grease all blank surfaces with grease: Cylinders Preserve all other blank surfaces with Amber/Tectyl 846 Spray or equivalent Storage: Store in a dry environment with humidity max 80% Commissioning: As per procedure in the User Manual Handling Lift the tool by its lifting ears only. Transport When the tool is in it s original crate, use a fork lift for lifting the crate only. The weight of the tool is indicated on the identification area of the tool, and also on its original transporting crate. MAINTENANCE & INSPECTION 35
36 Trouble shooting In all event where the elevator doesn't function as expected, carry out the following checks to identify the cause of the problem. 1. Check if the correct size components are installed. 2. Check if the elevator is well lubricated. MAINTENANCE & INSPECTION 36
37 SIZE COMPONENTS SiIZE SIZE COMPONENTS 37
38 6. SIZE COMPONENTS P/N BC Bushing DP-Size 18 Bore Code P/N Bushing 2.3/8 EU /8 IU /8 EU /2 IU /2 EU IU EU /2 IU+IEU /2 EU IEU / /2 IEU / / /8 IEU /8 IEU DP-Size /8 IU /8 EU /2 IU /2 EU IU /2 IU+IEU IEU /2 IEU /8 IEU mm For Drill Collar with Zip Groove Bore Code P/N Bushing 4.1/ / / / SiIZE COMPONENTS 5.1/ / / / / / / / /
39 For Drill Collar without Zip Groove 3.1/ / / / / / / / / / / / / / / / Tubing 2.3/8 P /8 U /8 P /8 U /2 P /2 U P U /2 P /2 U P U /2 P /2 U SiIZE COMPONENTS 39
40 Casing 4.1/ / / / / / All current Bore Codes are according to the size table of Page 11. SiIZE COMPONENTS 40
41 DRAWINGS & SPARE PARTS 41 DRAWINGS & SPARE PARTS
42 7. DRAWINGS AND SPARE PARTS P/N Y VES-CL 150 Center Latch Elevator Item not shown DRAWINGS & SPARE PARTS 42
43 Parts list Y Item Qty. Part No. Description Y-BF B+V Type VES-CL-150 Center Latch Elevator Latch * Latch Lock Assy Latch Pin * Latch Lock Pin * Latch Spring * Latch Lock Spring * Retaining Ring * Cotter Pin Hinge Pin * Retaining Ring Link Block Screw Nut * Cotter Pin * Grease Nipple * Protection Cap * Rivet Pin * Warning sign "GREASE DAILY" * Warning sign Blohm + Voss * Warning sign "squeeze danger" * Sticker Hotline * Screw * Fitting Key * Screw * Securing Plate * Label: Patent Number * Bowl Fitting Handle *Spare Parts DRAWINGS & SPARE PARTS 43
44 P/N Y VES-CL 250 Center Latch Elevator DRAWINGS & SPARE PARTS Item not shown 27 GREASE DAILY
45 Parts list Y Item Qty. Part No. Description BF VES- CL Latch * Latch Lock Assy Latch Pin * Latch Lock Pin * Latch Spring * Latch Lock Spring * Retaining Ring * Retaining Ring Hinge Pin * Retaining Ring Link Block Screw Nut * Cotter Pin * Grease Nipple * Dowel Pin * Screw * Fitting Key * Screw * Securing Plate * Warning sign Blohm + Voss * Label: Patent Number * Bowl Fitting Handle * Warning sign "GREASE DAILY" 28 0, * Safety Rope for Screws * Protection Cap * Warning sign "squeeze danger" * Sticker Hotline *Spare Parts DRAWINGS & SPARE PARTS 45
46 Spare Parts for VES-CL 350 Center Latch Elevator DRAWINGS & SPARE PARTS 46
47 Parts list Y Item Qty. Part No. Description Body Part Body Part Latch Latch Pin * Latch Spring * Latch Lock * Latch Lock Pin * Latch Lock Spring Hinge Pin Link Block * Dowel Pin * Holding plate * Safety sheet * Screw * Fitting Key * Washer with TAP * Screw * Cotter Pin Nut * Retaining Ring Screw * Screw * Safety sheet * Nut * Grease Nipple * Warning sign "GREASE DAILY" * Warning sign Blohm + Voss * Label: Patent Number * Sticker Hotline * Bowl Fitting Handle * Protection Cap *Spare Parts DRAWINGS & SPARE PARTS 47
48 Y VES-CL 500 Center Latch Elevator DRAWINGS & SPARE PARTS
49 Parts list Y Item Qty. Part No. Description VES-CL-500, Frame Latch * Stop Bolt * Retaining Ring * Hinge Pin * Retaining Ring * Latch Spring * Latch Lock Spring Latch Lock Latch Pin Hinge Pin * Bush * Securing Plate * Protector * Screw Screw * Washer * Dowel Pin * Holding plate * Screw Link Block Screw Nut * Cotter Pin * Label: Patent Number * Grease Nipple * Protector Ring * Bowl Fitting Handle * Warning sign "GREASE DAILY" * Warning sign Blohm + Voss * Warning sign "squeeze danger" * Protection Cap * Sticker Hotline *Spare Parts DRAWINGS & SPARE PARTS 49
50 P/N Y VES-CL 750 Center Latch Elevator DRAWINGS & SPARE PARTS Item not shown
51 Parts list Y Item Qty. Part No. Description VES-CL 750, Part VES-CL 750, Part Latch Hinge Pin * Latch Lock Latch Pin * Latch Lock Pin * Stop Bolt * Rivet Pin * Distance Bushing * Latch Lock Spring * Latch Spring * Protector Link Block Link Block 1 - CL * Protection Cap * Grease Nipple * Plate * Screw * Safety sheet * Screw * Retaining Ring Screw * Protector Ring Nut * Cotter Pin * Bowl Fitting Handle * Retaining Ring * Label: Patent Number * Sticker Hotline * Warning sign "squeeze danger" * Warning sign Blohm + Voss * Warning sign "GREASE DAILY" *Spare Parts DRAWINGS & SPARE PARTS 51
52 P/N Y VES-CL 1000 Center Latch Elevator DRAWINGS & SPARE PARTS Item not shown Bowl (optional) 52
53 Parts list Y Item Qty. Part No. Description VES-CL 1000, Part VES-CL 1000, Part Latch Hinge Pin Latch Pin * Latch Lock * Latch Lock Pin * Stop Bolt * Rivet Pin * Latch Spring * Latch Lock Spring Link Block Screw Nut * Cotter Pin * Plate * Screw * Safety sheet * Warning sign Blohm + Voss * Warning sign "squeeze danger" * Retaining Ring * Grease Nipple * Protector H* Distance Bushing * Screw * Label: Patent Number * Retaining Ring Link Block * Protector Ring * Warning sign "GREASE DAILY" * Protection Cap * Bowl Fitting Handle * Sticker Hotline *Spare Parts DRAWINGS & SPARE PARTS 53
54 Wear Bushing Parts list BC Item Qty. Description 1 1 Wear Bushing 2 6 Washer 3 6 Spring ring 4 6 Screw DRAWINGS & SPARE PARTS Bore code BC BC Wear Bushing Washer (6x) Spring Ring (6x) Screw (6x) BC BC BF BC BF BC BF BC 113 BC BF BF BC BF other sizes on request 54
55 Spare Parts Parts list Y-RSP Item Qty. Part No. Description Latch Lock Assy Latch Lock Pin Latch Spring Latch Lock Spring Retaining Ring Cotter Pin Retaining Ring Cotter Pin Grease Nipple Protection Cap Rivet Pin Warning sign "GREASE DAILY" Warning sign Blohm + Voss Warning sign "squeeze danger" Sticker Hotline Screw Fitting Key Screw Securing Plate Label: Patent Number Bowl Fitting Handle DRAWINGS & SPARE PARTS 55
56 Parts list Y-RSP Item Qty. Part No. Description Latch Lock Assy Latch Lock Pin Latch Spring Latch Lock Spring Retaining Ring Retaining Ring Retaining Ring Cotter Pin Grease Nipple Dowel Pin Screw Fitting Key Screw Securing Plate Warning sign Blohm + Voss Label: Patent Number Bowl Fitting Handle Warning sign "GREASE DAILY" Safety Rope for Screws Protection Cap Warning sign "squeeze danger" Sticker Hotline DRAWINGS & SPARE PARTS 56
57 Parts list Y-RSP Item Qty. Part No. Description Latch Spring Latch Lock Latch Lock Pin Latch Lock Spring Dowel Pin Holding plate Safety sheet Screw Fitting Key Washer with TAP Screw Cotter Pin Nut Retaining Ring Screw Screw Safety sheet Nut Grease Nipple Warning sign "GREASE DAILY" Warning sign Blohm + Voss Label: Patent Number Sticker Hotline Bowl Fitting Handle Protection Cap *Spare Parts DRAWINGS & SPARE PARTS 57
58 Parts list Y-RSP Item Qty. Part No. Description Stop Bolt Retaining Ring Hinge Pin Retaining Ring Latch Spring Latch Lock Spring Bush Securing Plate Protector Screw Washer Dowel Pin Holding plate Screw Cotter Pin Label: Patent Number Grease Nipple Protector Ring Bowl Fitting Handle Warning sign "GREASE DAILY" Warning sign Blohm + Voss Warning sign "squeeze danger" Protection Cap Sticker Hotline DRAWINGS & SPARE PARTS 58
59 Parts list Y-RSP Item Qty. Part No. Description Latch Lock Latch Lock Pin Stop Bolt Rivet Pin Distance Bushing Latch Lock Spring Latch Spring Protector Protection Cap Grease Nipple Plate Screw Safety sheet Screw Retaining Ring Protector Ring Cotter Pin Bowl Fitting Handle Retaining Ring Label: Patent Number Sticker Hotline Warning sign "squeeze danger" Warning sign Blohm + Voss Warning sign "GREASE DAILY" DRAWINGS & SPARE PARTS 59
60 Parts list Y-RSP Item Qty. Part No. Description Latch Lock Latch Lock Pin Stop Bolt Rivet Pin Latch Spring Latch Lock Spring Cotter Pin Plate Screw Safety sheet Warning sign Blohm + Voss Warning sign "squeeze danger" Retaining Ring Grease Nipple Protector H Distance Bushing Screw Label: Patent Number Retaining Ring Protector Ring Warning sign "GREASE DAILY" Protection Cap Bowl Fitting Handle Sticker Hotline DRAWINGS & SPARE PARTS 60
Blohm+Voss Pipe Handling Equipment Special Link Connector Technical Documentation Original instructions
Blohm+Voss Pipe Handling Equipment Special Link Connector Technical Documentation Original instructions Manual PN 554106-D Rev. 002, May 2012 Blohm + Voss Oil Tools 1 GENERAL INFORMATION Warnings and Note
More informationBlohm+Voss Pipe Handling Equipment Safety Clamps Type C and T Technical Documentation Original Instructions
Blohm+Voss Pipe Handling Equipment Safety Clamps Type C and T Technical Documentation Original Instructions Manual PN 88003-D Rev. 010, August 2013 Blohm + Voss is a trademark of Blohm + Voss Shipyards
More informationTECHNICAL DOCUMENTATION
Read before first use! VES-CL-1000 Elevator Hydraulically Operated Part No. 611000-Y-H Blohm + Voss Oil Tools Hermann-Blohm-Straße 2 20457 Hamburg Germany Telephone ++49 (0)40/3119-1826/1162 Fax ++49 (0)40/3119-8194
More informationBlohm + Voss Pipe Handling Equipment SDS Side Door Elevators 65, 100, 150, 250, 350 & 500 tons Technical Documentation Original Instructions
Blohm + Voss Pipe Handling Equipment SDS Side Door Elevators 65, 100, 150, 250, 350 & 500 tons Technical Documentation Original Instructions Manual PN 641020-Y-BC-D Rev 013, Mai 2013 Blohm + Voss Oil Tools
More informationBlohm + Voss Oil Tools
Blohm+Voss Pipe Handling Equipment VES-HCL 350 Elevator Hydraulically Operated Part no. 63000-Y-H-F (with closing signal) Technical Documentation Original Instructions Manual PN 63000-Y-H-F-D Rev 005 valid
More informationBlohm + Voss Oil Tools
Blohm + Voss Pipe Handling Equipment Rotary Hand Slips: RSM / RSX / LRS Drill Collar Slips: DCS / DCM / DCL Casing Slips: CSL / CSC Technical Documentation Original Instructions Manual PN 83500-D Rev 008,
More informationBlohm+Voss Pipe Handling Equipment FPS 500-AIR Flush Power Slip Technical Documentation Original Instructions
Blohm+Voss Pipe Handling Equipment FPS 500-AIR Flush Power Slip Technical Documentation Original Instructions Manual 754000-AIR-D Rev 000, October 2012 Blohm + Voss Oiltools 1 GENERAL INFORMATION Warnings
More informationBlohm + Voss Pipe Handling Equipment ABVC-200 Sliptype Elevator Technical Documentation Original Instructions
Blohm + Voss Pipe Handling Equipment ABVC-200 Sliptype Elevator Technical Documentation Original Instructions Blohm + Voss Oil Tools Manual PN 672600-Y-D Rev 003, February 2012 1 GENERAL INFORMATION Warnings
More informationBlohm + Voss Pipe Handling Equipment BVE / BVS 750 Frame 1 air operated 4.1/2 14 Technical Documentation Original Instructions
Blohm + Voss Pipe Handling Equipment BVE / BVS 750 Frame 1 air operated 4.1/2 14 Technical Documentation Original Instructions Manual PN 710000-Y-A-D Rev 004, February 2012 Blohm + Voss Oil Tools 1 GENERAL
More informationBlohm + Voss Oil Tools
Blohm+Voss Pipe Handling Equipment Hydraulic Operated Elevator/Spider BVE / BVS 500 PN 752000-Y-H-VC 4.1/2-14 Technical Documentation Original Instructions Manual PN 752000-Y-H-VC-D Rev 001, February 2012
More informationBlohm+Voss. BVE / BVS /8 7.5/8 250 metric tons
Blohm+Voss BVE / BVS 250 2.3/8 7.5/8 250 metric tons Part-No. 725000 READ THESE INSTRUCTIONS BEFORE USE! Blohm+Voss Oil Tools Hermann-Blohm-Straße 2 20457 Hamburg Germany Telephone ++49 (0)40/3119-1826/1162
More informationBlohm + Voss B+V hinged Adapter
Blohm + Voss B+V hinged Adapter 49 /2 to 37 /2 for RT National Inspection and maintenance procedure Part No. 55320 Blohm+Voss Oil Tools Hermann-Blohm-Straße 2 20457 Hamburg Germany Telephone ++49 (0)40/39-826/62
More informationBlohm+Voss BVE/S-750 Elevator/Spider 4 ½ 14 Pipe Range Diameter
Read before first use! Blohm+Voss BVE/S-750 Elevator/Spider 4 ½ 14 Pipe Range Diameter Part No. 710000-Y-H hydraulic version Blohm + Voss Oil Tools Hermann-Blohm-Straße 2 20457 Hamburg Germany Telephone
More informationBVM Corporation TYPE MS TONG 6,500 FT/LBS. TORQUE
Page 1 BVM Corporation TYPE MS TONG 6,500 FT/LBS. TORQUE Part number: Serial Number: BVM CORPORTION TYPE MS TONG 6,500 FT/LBS. TORQUE WRNING: Manual tongs which have experienced excessive wear or are found
More informationCONTROL UNIT FOR POWER SLIPS PN:
CONTROL UNIT FOR POWER SLIPS PN: 757105 Blohm + Voss Oiltools Herrmann-Blohm-Strasse 2 20457 Hamburg Germany Telephone ++49 (0)40/3119-1826/1162 Fax ++49 (0)40/3119-3305 Revision 001, February 2012 All
More informationPipe Handling Equipment
Pipe Handling Equipment Blohm+Voss Repair GmbH Oil Tool Division Hermann-Blohm-Straße 2 20457 Hamburg, Germany Phone: +49-40-31 19-81 42 Fax: +49-40-31 19-34 00 E-mail: info@blohmvoss-oiltools.com www.blohmvoss-oiltools.com
More informationBlohm + Voss Oil Tools, LLC GraySpin Mark 40 Hydraulic Drill Pipe Spinner With and without Hydraulic Lift Technical Documentation
Blohm + Voss Oil Tools, LLC GraySpin Mark 40 Hydraulic Drill Pipe Spinner With and without Hydraulic Lift Technical Documentation 1 GENERAL INFORMATION Warnings and Notes WARNING: A WARNING INDICATES A
More informationBefore equipment use, please read this operation manual carefully. Serial Number: Date Purchased:
Pushed & Geared Trolleys OPERATION MANUAL This operation manual is intended as an instruction manual for trained personnel who are in charge of installation, maintenance, repair etc. Before equipment use,
More informationTranslation of the Original operating instructions Lifting device Z 70 /...
Translation of the Original operating instructions Lifting device Z 70 /... Content 1. Lifting device / Correct use according to regulations 2. Basic principles 3. General information 4. Special remarks
More informationHST -LS Interlocking device (Translation of Original Manual)
Installation and Operating Manual for Components HST -LS Interlocking device (Translation of Original Manual) HST-LS Ident.-No.: 10268 HST-LS Ident.-No.: 10269 HST-LS, pictured Ident-Nr. 10269 The image
More informationOperating Manual TWN 0121/1. Lifting point, screw-type TWN 0122 TWN 0123 TWN 0127 TWN 1120 TWN 1830 TWN 1890
TWN 0121/1 Operating Manual Lifting point, screw-type TWN 0122 TWN 0123 TWN 0127 TWN 1120 TWN 1830 TWN 1890 THIELE GmbH & Co. KG Werkstraße 3 Tel: +49 (0)2371 / 947-0 58640 Iserlohn www.thiele.de B07905-D
More information350 Ton Elevator Links/Link Extensions Operation Manual
TECHNICAL MANUAL 350 Ton Elevator Links/Link Extensions Operation Manual 2005-2015 Texas International Oilfield Tools, LTD. Published by Texas International Oilfield Tools, LTD, Engineering 14620 Henry
More informationBlohm + Voss Oil Tools Circular Buttons, Inserts and Dies Catalog
Blohm + Voss Oil Tools Circular Buttons, Inserts and Dies Catalog A company of ThyssenKrupp Marine Systems Blohm + Voss Repair Blohm + Voss Oil Tools General Information Brochure Contents INSERTS: DIMENSIONS...
More informationSide Door Elevator SDS
Pipe-Handling-Equipment Hoisting Equipment Side Door Elevator SDS SDS / VES SDS / SDS-H Type Series Manual and hydraulic operated elevators SDS Type Series Side Door Collar Type Elevator VES SDS Type Series
More informationSafelift Overhead Runway Beams & Rolling Beam Cranes
Operation & Maintenance Instructions Instructions for Safe Use Safelift Overhead Runway Beams & Rolling Beam Cranes Certification Safelift overhead runway beams and rolling beam cranes are lifting appliances
More informationSafety Clamp Operation Manual
TECHNICAL MANUAL Safety Clamp Operation Manual 2005-2016 Texas International Oilfield Tools, LTD. Published by Texas International Oilfield Tools, LTD, Engineering 14620 Henry Road. Houston, TX 77060 www.texasinternational.com
More informationInstruction Manual. Unique 7000 Series Aseptic - Manually Operated ESE02421-ENUS Original manual
Instruction Manual Unique 7000 Series Aseptic - Manually Operated 2210-0042 ESE02421-ENUS1 2013-03 Original manual Table of contents The information herein is correct at the time of issue but may be subject
More informationRectangular Door L-VAT with pneumatic actuator double acting
Rectangular Door L-VAT with pneumatic actuator double acting This manual is valid for the products: 0 7 5 1 0 U A 2 4 0 0 0 1 4 character option code Size 10... 46 x 236 12... 50 x 336 Actuator 24... without
More informationInstructions for installation, operation and maintenance of: GATE VALVE
Instructions for installation, operation and maintenance of: GATE VALVE GEN GAC GAF/GENF TERMOVENT SC Temerin Republic of Serbia Instruction for installation, operation and maintenance: Table of Contents
More informationCENTAX-SEC Series B Assembly and operating instructions CX BFS1-LE/SE-**-B M EN Rev. 1
Assembly and operating instructions -**-B Contents 1 General remarks... 5 2 Safety... 6 2.1 Safety remarks... 6 2.1.1 Signal words... 6 2.1.2 Pictograms... 7 2.2 Qualification of deployed personnel...
More informationINSTRUCTION MANUAL. Pacific Self-locking Beam Trolleys Pacific Adjustable Angle Clamps Pacific Top Girder Clamps
INSTRUCTION MANUAL Pacific Self-locking Beam Trolleys Pacific Adjustable Angle Clamps Pacific Top Girder Clamps IMPORTANT Please read this instruction manual before using these products. This manual contains
More informationTop Drive System Installation and Commissioning Manual
TDS-1000A Top Drive System Installation and Commissioning Manual SM01040 General Information Conventions.............................. 1-3 Notes, Cautions, and Warnings......................... 1-3 Illustrations.........................................
More informationAttachment Solutions. Superlift System. Operators Manual
Attachment Solutions Superlift System Operators Manual TABLE OF CONTENTS Section I. General Information... 3 Section II. Safety... 3 Section III. Identification of Major Components... 5 Section IV. Setup...
More informationPremium Supply. Direct Push. Models PCK-3530-DP PCK DP PCK-530-DP. Operator s Manual and Installation Instructions
Direct Push Models PCK-3530-DP PCK-3530-2DP PCK-530-DP Operator s Manual and Installation Instructions Premium Supply 2038 West Interstate 30 866-934-0777 Proud members of: and June 20, 2018 Table of Contents
More informationPAGE 1 OF 5 HEALTH, SAFETY & ENVIRONMENTAL MANUAL PROCEDURE: S360 Overhead Cranes & Lifts Procedure REV 4.0 8/14/2012
PAGE 1 OF 5 PURPOSE: OVERHEAD CRANES AND LIFTS PROCEDURE The purpose of this procedure is to define the safety and training requirements for use of overhead cranes and lifts. Procedure: Definitions Designated
More informationCE Operating and Maintenance Manual
CE Operating and Maintenance Manual Demolition and Sorting Grab Type S 450-D Zijtveld Grijpers The Netherlands www.zijtveld-grijpers.nl 1 Introduction Dear User, The Demolition/Selector grab is a piece
More informationUSE AND MAINTENANCE MANUAL
LATERAL TURNOVER 360 ORIGINAL INSTRUCTIONS INTRODUCTION This manual includes instructions for assembly, maintenance (regular and extraordinary), and for possible faults with remedies. The instructions
More informationMiller Compact Manual Quick Couplers
Miller: Issue 2 Miller Compact Manual Quick Couplers For Mini Excavators (1 to 10 tonne) and Backhoe Loaders Installation Guide and Operator s Instructions IMPORTANT Keep this manual with the machine at
More information500kg HYDRAULIC TABLE LIFT
Product Code: 6007T OWNER S MANUAL PRODUCT CODE: 6007T 500kg HYDRAULIC TABLE LIFT Working Load Limit 500kg Maximum Height 1575mm Minimum Height 440mm Table Dimensions 1010x520mm Wheel Diameter 150mm Made
More informationInnovative Landing String system for ultra-deep offshore
Innovative Landing String system for ultra-deep offshore V. Flores, J.Franchi, S. Granger Vallourec Drilling Products A. Vierke, J. Grotherr Blohm+Voss Oil Tools Introduction Offshore industry trends:
More informationSerial N... MX1 Chain Driven Pipe Cutting and Bevelling Machine Parts and Operating Manual
Serial N... MX1 Chain Driven Pipe Cutting and Bevelling Machine Parts and Operating Manual Table of contents Section Description Page 1.0 General Information 2 2.0 Specification 2 2.1 General Specification
More informationPackage Contents Part A (3) I-Beam (1) Base (2) Other parts
Page 1 Installation Instructions for 81245 Adjustable Height Gantry Crane 1-Ton Capacity Table of Contents Important Safety Information pg. 2 Specific Operation Warnings pg. 2 Main Parts of Product pg.
More informationCENTAX-TEST Assembly and operating instructions 053C GB3. M EN Rev. 1
Assembly and operating instructions Contents 1 General remarks... 5 2 Safety... 6 2.1 Safety remarks... 6 2.1.1 Signal words... 6 2.1.2 Pictograms... 7 2.2 Qualification of deployed personnel... 7 2.3
More informationDC Master 24/ A
USERS MANUAL DC Master 24/12 50-60A DC-DC converter MASTERVOLT Snijdersbergweg 93, 1105 AN Amsterdam The Netherlands Tel.: +31-20-3422100 Fax.: +31-20-6971006 www.mastervolt.com ENGLISH Copyright 2015
More informationLineman s Hoist. Operating, Maintenance & Parts Manual. Follow all instructions and warnings for LMST680-2
Lineman s Hoist LMST0- Operating, Maintenance & Parts Manual Lineman s Hoist Follow all instructions and warnings for inspecting, maintaining and operating this hoist. The use of any hoist presents some
More informationOperating and Maintenance Manual. for. HADEF overhead crane. as jointed crane TA
5.52.714.00.1.0 Edition 03.2004 GB Operating and Maintenance Manual for HADEF overhead crane as jointed crane TA Subject to changes. 1 HADEF Table of Contents 1 General Page 3 2 Product description Page
More informationMG12K24T60V4 Mechanical Grapple
170 State Route 271 Attachment Solutions MG12K24T60V4 Mechanical Grapple Operators Manual KENCO Mechanical Grapple Operation Manual 1 TABLE OF CONTENTS 170 State Route 271 Section I. General Information....
More informationSafe Operating Practices & Maintenance Manual
tcamerican.com sales@tcamerican.com 763-479-7000 11110 Industrial Circle NW, Suite A, Elk River, MN 55330 Safe Operating Practices & Maintenance Manual Section Subject Page A. General 2 B. Operator Qualifications
More information580RK SERVICE GUIDELINES For coupling models: 580 & 580J
580 Coupling THE FIRST NAME IN QUALITY COUPLINGS 580RK SERVICE GUIDELINES For coupling models: 580 & 580J BEFORE GETTING STARTED: This procedure should only be performed by a qualified mechanic. Measure
More informationOPERATIONS MANUAL LEVER CHAIN HOIST
OPERATIONS MANUAL LEVER CHAIN HOIST IMPORTANT SAFETY INFORMATION Please read, understand and follow all safety information contained in these instructions prior to the use of this hoist. Retain these instructions
More informationMEYER-Rotating Fork Positioners are attachments used to transport loads and replace
This MEYER-Attachment complies in every aspect to the EC-Safety Guidelines. The Certificate of Conformation / Declaration by the Manufacturer has been delivered with the attachment. The CE-Symbol can be
More information1 Clearheart Construction Co., Inc. Mobile Crane - Onshore MOBILE CRANES Cranes and derricks
Mobile Crane - Onshore MOBILE CRANES Cranes and derricks. - 1926.550 Cranes, like all pieces of heavy equipment, if not properly operated, inspected and maintained have a potential for causing major bodily
More informationOperating manual. Custom made gearboxes
Operating manual Custom made gearboxes DSS-Nr. 100389549 DSS-Rev. 001 Datum 16.01.2018 Contents Contents 1 General information 3 1.1 Using the operating manual 3 1.2 Warnings in this operating manual 4
More informationOperation & Service Manual
Operation & Service Manual Model: 02-1248-0112 12 Ton Single Stage Jack 11/2004 Rev. 02 Includes Illustrated Parts Lists 1740 Eber Rd Tronair, Inc. Phone: (419) 866-6301 Holland, OH 43528-9794 www.tronair.com
More informationInstructions for Fitting, Operating and Maintenance Canopy Door RE / (St.: )
EN Instructions for Fitting, Operating and Maintenance Canopy Door 1 818 012 RE / (St.: 12.2010) 12.2010 ENGLISH Contents 1 Safety Instructions... 3 1.1 Qualified persons... 3 1.2 Symbols and signal words
More informationTurbocharger / VTR..0, VTR..1 Original assembly instructions English
Assembly Instructions Turbocharger / VTR..0, VTR..1 Original assembly instructions English This document is valid for the VTR..0/..1 series: VTR160, VTR200, VTR250, VTR320, VTR400 VTR161, VTR201, VTR251,
More informationInstallation Operation Maintenance. LSSN Butterfly Valve AGA Approved 50MM - 150MM. QAD#IM6055.REVA
LSSN Butterfly Valve Installation Operation Maintenance Licence Number: 5326 www.challengervalves.com.au 1 Index 1. INTRODUCTION 1.1 Design Features 3 1.2 Flange and Pipe Compatibility 4 1.3 Operating
More informationOperation and Maintenance Instructions
Hydratight Limited Bentley Road South Darlaston West Midlands WS10 8LQ United Kingdom Tel: +44 121 50 50 600 Fax: +44 121 50 50 800 E-mail: enquiry@hydratight.com Website: www.hydratight.com TOP COLLAR
More informationOperation manual Flexible pin type coupling according to KWN 22014
Operation manual Flexible pin type coupling according to KWN 22014 Author: Dipl.-Ing.. V. Hausdorf 24.01.2005 gez. V. Hausdorf Approved: Dr.-Ing. Ch. Spensberger 24.01.2005 gez. Dr.-Ing. Ch. Spensberger
More informationoperating instruction
operating instruction a.560pn #125101 DE, EN, FR, SE Table of Contents Installation... 3 Tool use...4-5 Safety precautions...6-7 Troubleshooting and maintenance... 8 Technical specification... 9 Spare
More informationOPERATION & SERVICE MANUAL DRUM (MANUAL DRUM LIFTER)
OPERATION & SERVICE MANUAL DRUM-55-36 (MANUAL DRUM LIFTER) Vestil Manufacturing Corp. 2999 North Wayne St., Angola, IN 46703 Ph: 260-665-7586. Fax: 260-665-1339 E-mail: Sales@vestil.com Website: www.vestil.com
More informationTechnical Description Edition 2007 Mounting, maintenance and repair of propshafts with flanged universal joints
Technical Description Edition 2007 Mounting, maintenance and repair of propshafts with flanged universal joints 1. Recommendations Assembly, disassembly, maintenance and repair of propshafts should be
More informationKeystone Butterfly valves ParaSeal Installation and maintenance instructions
Before installation these instructions must be fully read and understood Please read these instructions carefully Hazard potentials: disregarding of instructions improper use of product insufficiently
More informationDistributed by Tri-State Equipment Company Inc. Web: PH: FAX:
Lineman s Hoist Distributed by Tri-State Equipment Company Inc. Email: sales@tsoverheadcrane.com Web: www.tsoverheadcrane.com PH: -869-00 FAX: -869-6 LMST680 Operating, Maintenance & Parts Manual Lineman
More informationTABLE OF CONTENTS INSTALLATION & OPERATING INSTRUCTION MANUAL FOR MODEL PRC-- POWER ROLLER CONVEYOR
TABLE OF CONTENTS INSTALLATION & OPERATING INSTRUCTION MANUAL FOR MODEL PRC-- POWER ROLLER CONVEYOR 1. INSTALLATION 2 1.1. GENERAL INSTALLATION 2 1.1.1. Building Connections 3 2. OPERATION 3 2.1. GENERAL
More informationPURPOSE... 1 II. SCOPE... 2 III. REFERENCES... 2 IV. RESPONSIBILITIES...
Reed College 3203 Southeast Woodstock Blvd. Portland Oregon 97202-8199 Crane Safety Policy Effective Date: Revision Dates: February 9, 2011, June 25, 2012, July 2016 Review Dates: I. PURPOSE... 1 II. SCOPE...
More informationSpecial Purpose Overrunning Clutches ep 300 thru 1027 (less Oil Seals)
Special Purpose Overrunning Clutches ep 300 thru 1027 (less Oil Seals) P-222-30 Bulletin 4701 Service & Installation Instructions introduction EP models are special purpose ball bearing clutches suitable
More informationGreat Western Painting Crane Operator - Offshore CRANE OPERATOR - OFFSHORE
Crane Operator - Offshore CRANE OPERATOR - OFFSHORE Cranes, like all pieces of heavy equipment, if not properly operated, inspected and maintained have a potential for causing major bodily injury or property
More informationREDEXIM-BLEC BOX-GRADER 1800 / LASER- GRADER Serial number: User Manual and Parts Book. Original manual
User Manual and Parts Book REDEXIM-BLEC BOX-GRADER 1800 / LASER- GRADER 1800 Serial number: Kwekerijweg 8 3709JA Zeist The Netherlands Tel.: (31)30-6933227 Fax: (31)30-6933228 Email: verti-drain@redexim.com
More informationOperating & Maintenance Manual For Steam Conditioning Valve
For Steam Conditioning Valve 1 Table of Contents 1.0 Introduction 3 2.0 Product description 3 3.0 Safety Instruction 4 4.0 Installation and Commissioning 5 5.0 Valve Disassembly 6 6.0 Maintenance 6 7.0
More informationTension Meter. Edition FT 03.E. FT Series. Instruction Manual. Valid as of: Please keep the manual for future reference!
Tension Meter FT Series S C H M I D T c o n t r o l i n s t r u m e n t s Edition FT 03.E Model FT Instruction Manual Valid as of: 01.09.2011 Please keep the manual for future reference! Contents 1 Warranty
More informationA company of ThyssenKrupp Elevator. ThyssenKrupp Aufzugswerke. Operating Manual. Oil buffer
A company of ThyssenKrupp Elevator ThyssenKrupp Aufzugswerke Operating Manual Oil buffer OPERATING MANUAL Printer s imprint All rights reserved. Copyright by: THYSSENKRUPP AUFZUGSWERKE GMBH P.O. box 23
More informationModel 240K / 240KL Coupling
MANUFACTURING CO. THE FIRST NAME IN QUALITY COUPLINGS Installation, Inspection, Operation & Maintenance Guide Model 240K / 240KL Coupling IMPORTANT Read these instructions completely before installing,
More informationKeystone Figure 85/86 Check valves Installation and Maintenance Instructions
Please read these instructions carefully 1.3 Handling 1.3.1 Packed valves Lifting and handling of the packed valves in crates should be carried out by appropriate lifting equipment. If a fork lift truck
More informationPORTABLE LADDER SAFETY PROGRAM
PORTABLE LADDER SAFETY PROGRAM REGULATORY STANDARD: OSHA - 29 CFR 1910.25 Portable Wood Ladders* - 29 CFR 1910.26 Portable Metal Ladders* - 29 CFR 1926.1050-1060* *The above standards are intended to prescribe
More informationGunnebo Lifting Offshore programme - accessories. High consistent quality generates long durability and safety
Gunnebo Lifting Offshore programme - accessories High consistent quality generates long durability and safety DNV 2.7-1 certificate We are certified by DNV to make type approval in 271 quality (Offshore
More informationE17H RAIL WHEEL INSPECTION
E17H RAIL WHEEL INSPECTION PURPOSE AND SCOPE This Procedure applies to all items of rolling stock purchased or acquired through hiring or other means by Laing O Rourke for the railway operations they will
More informationArmon Edero. User manual
User manual Armon Edero Foreword.... 2 Symbols used 2 Intended use.... 2 About the Armon Edero... 2 Mounting options of the Edero 2 Braces. 3 How to set up the Armon Edero.. 3 How to attach the brace to
More informationTurbocharger / A100-L Original assembly instructions English
Assembly Instructions Turbocharger / A100-L Original assembly instructions English This document is valid for the A100-L series: A165-L, A170-L, A175-L, A180-L, A185-L, A190-L Purpose The assembly instructions
More informationInstallation, Operating and Maintenance Instructions. Rotating Machine Screw Actuators. With Parts List Publication Part No.
Installation, Operating and Maintenance Instructions With Parts List Publication Part No. SK-2389-R1 Rotating Machine Screw Actuators 1/4 Through 1-Ton Capacity Caution This manual contains important information
More informationHYDRAULIC PALLET TRUCK. MODEL No: PTE550 PART Nos OPERATION & MAINTENANCE INSTRUCTIONS
HYDRAULIC PALLET TRUCK MODEL No: PTE550 PART Nos 7630171 OPERATION & MAINTENANCE INSTRUCTIONS 0604 Please read these instructions carefully before operating the truck Thank you for purchasing this CLARKE
More informationLincoln Hoist. Web Hoist Operating Manual. Lincoln Hoist
Lincoln Hoist Web Hoist Operating Manual Lincoln Hoist Mfg. by Lincoln Precision Machining Company 121 Creeper Hill Road, P.O. Box 458, North Grafton, MA 01536 USA Toll Free (888) 306-7222 Phone (774)
More informationProvided by: Operating, Maintenance & Parts Manual
Provided by: www.hoistsdirect.com TB681.qxd 11/29/2004 3:04 PM Page 1 Operating, Maintenance & Parts Manual TB603 Manually Lever Operated Chain Hoist 1100 POUNDS MAXIMUM CAPACITY (500 kg) Follow all instructions
More informationAUTOMATIC AIRSPRAY GUN
INSTRUCTION MANUAL AUTOMATIC AIRSPRAY GUN Manual : 0407 573.011.212 Date : 19/07/04 Supersede : KREMLIN REXSON - Site de Stains : 150, avenue de Stalingrad 93 245 - STAINS CEDEX - FRANCE Téléphone : 33
More informationOWNER S MANUAL PRODUCT CODE: 2006T
Jul-18 Product Code: 2006T OWNER S MANUAL PRODUCT CODE: 2006T HYDRAULIC PIPE BENDER 12,000KG Model Capacity Bending Die No of Attachments 12,000kg 1/2", 3/4", 1", 1-1/4", 1-1/2", 2" 6 Made in China to
More informationTONS. Before each shift: Before operating: Before initial operation of hoist:
LEVER HOIST 0.25 9 TONS Manual Notice It is the responsibility of the owner/user to install, inspect, test, maintain, and operate these lever hoists in accordance with ASME B30.21, Safety Standard for
More informationINSTRUCTION MANUAL. I/P Converter DSG BXXY3Z DSG BXXY4Z
INSTRUCTION MANUAL I/P Converter DSG BXXY3Z DSG BXXY4Z Revision 2.0 3.626 016136 en Page 1/15 Should you have any questions concerning the I/P converter, please contact the Service Department of the Product
More informationUser Manual. T29870 Beam Clamp. Original Instructions. Rev /08//14.
User Manual T29870 Beam Clamp Original Instructions Rev 1.0-12/08//14 www.doughty-engineering.co.uk Contents Introduction... 2 Exclusion of Liability... 2 Safety Instructions... 2 Operation... 3 Maintenance...
More informationModel 6 Weld-On Drawbar Eye
MANUFACTURING CO. THE FIRST NAME IN QUALITY COUPLINGS Installation, Inspection, Operation & Maintenance Guide Model 6 Weld-On Drawbar Eye IMPORTANT Read these instructions completely before installing,
More informationBaumann Way Control Valve
Instruction Manual 24003 Valve Baumann 24003 3-Way Control Valve Contents Introduction... 1 Scope of Manual... 1 Safety Precautions... 2 Educational Services... 3 Maintenance... 3 Installation... 3 Air
More informationI. Safety Requirement WARNING. ATV/UTV Winch
1 2 ATV/UTV Winch Thank you for purchasing a COMEUP Winch. This manual covers operation and maintenance of the winch. All information in this publication is based on the latest production information available
More informationOPERATOR S MANUAL GEARED BEAM TROLLEY 1 TON THROUGH 30 TON QUICK ADJUST TROLLEY 1 TON THROUGH 10 TON
OPERATOR S MANUAL PUSH BEAM TROLLEY 0.5 TON THROUGH 10 TON GEARED BEAM TROLLEY 1 TON THROUGH 30 TON QUICK ADJUST TROLLEY 1 TON THROUGH 10 TON These products meet or exceed the following standards: CE AS1418.2
More informationCO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080
CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080 STI S.r.l has taken every care in collecting and verifying the documentation contained in this Instruction Manual. The information herein contained are
More informationService Jacks. Operating Instructions & Parts Manual. Model Number. Capacity 4 Ton 4 Ton Air/ Manual 10 Ton 10 Ton Air/ Manual HW93657/ HW93660
Service Jacks Operating Instructions & Parts Manual Model Number HW93657 HW93667 HW93660 HW93662 Capacity 4 Ton 4 Ton Air/ Manual 10 Ton 10 Ton Air/ Manual Made in North America HW93657/ HW93660 HW93667/
More informationKEYSTONE. Check valves Figure 85/86 Installation & Maintenance Instructions. Figure 85. Figure 86.
KEYSTONE Please read these instructions carefully. This symbol indicates important messages and safety instructions. Hazard potentials: disregarding of instructions improper use of product insufficiently
More informationInstallation and Operation Manual
1645 Lemonwood Dr. Santa Paula, CA 93060 USA Toll Free: 1 (800) 253-2363 Tel: 1 (805) 933-9970 rangerproducts.com Ranger Floor Jack Installation and Operation Manual Manual Revision B July 2017 Manual
More informationOperating Manual for Automatic sprayvalve KA-2 / GT
Operating Manual for Automatic sprayvalve KA-2 / GT KA-2 / GT, round spray with clamp (option) KA-2 / GT, flat spray with clamp (option) Read this manual carefully before installing, operating or servicing
More informationBLAZER 9000 LUBE LIFT OPERATOR AND PARTS MANUAL
BLAZER 9000 LUBE LIFT OPERATOR AND PARTS MANUAL Blazer 9000 Lube Lift Operator s Manual Note: Instructions must be read thoroughly before installing, operating, or maintaining the lift. Devon Lube Center
More informationUser manual Pipe notcher Type: AL 1-2E
User manual Pipe notcher Type: AL 1-2E Page 1 of 27 Table of contents 1. Foreword... 4 1.1. Name of machine... 4 1.2. Warning... 4 1.3. Target group for each chapter... 4 1.4. Symbols... 4 1.5. Re-ordering
More informationFORUM Pipe Handling Equipment
FORUM Pipe Handling Equipment General Catalog Handling Tools 11.2017 FORUM Pipe Handling Equipment Brochure Contents 1250 1750 TON EqUIPmENT... 04 LINkS / BAILS... 06 BECkETS... 11 ELEvATORS... 12 TUBING
More information