1 Rectangular Door L-VAT with pneumatic actuator double acting This manual is valid for the products: U A character option code Size x x 336 Actuator without solenoid with solenoid x x x x 420 Body material x x x x 420 0X... misc. A... aluminum H... aluminum hard anodized E... stainless steel Flange type U... Actuator mounted on same surface as opening V... Mounting surface for actuator and opening are perpendicular C... Body without bonnet flange, gate maintenance through body opening on rear The respective product identification is marked on each door in the following or similar way : made in Switzerland Fabrication No.:.. patented /.. A /15

2 Explanation of symbols: Read declaration carefully before you start any other action! Keep body parts and objects away from the valve opening! Attention! Hot surfaces; do not touch! Product is in conformity with EC guidelines, if applicable! Loaded springs and/or air cushions are potential hazards! Disconnect electrical power and compressed air lines. Do not touch parts under voltage! Wear gloves! Read these «Installation, Operating & Maintenance Instructions» and the enclosed «General Safety Instructions» carefully before you start any other action! 2/15

3 Imprint: Manufacturer Website Phone Fax Publisher Editor Print Copyright VAT Vakuumventile AG 2008 No part of these Instructions may be reproduced in any way (photocopies, microfilms or any other reproduction processes) nor may it be manipulated with electronic systems, duplicated or distributed without written permission from VAT. Offenders are liable to pay damages. The original VAT firmware and updated state of the art versions of the VAT firmware are intended for use with VAT products. The VAT firmware contains a limited, time unlimited user license. The VAT firmware may not be used for purposes other than those intended nor is it permitted to make copies of the VAT firmware. In particular, it is strictly forbidden to give copies of the VAT firmware to other people. The use of trade names, brand names, trademarks, etc. in these Instructions does not entitle third parties to consider these names to be unprotected and to use them freely. This is in accordance with the meaning of the laws and acts covering brand names and trademarks. 3/15

4 Intended Use of Product Use product for vacuum applications under the conditions indicated in chapter «Technical data» only! Other applications are only allowed with the written permission of VAT. Technical specifications are defined in the Product data sheet Dimensions are defined in the corresponding dimensional drawings for each product Installation Leave the door in the sealed plastic bag as long as possible in order to protect it from dust and particles. The door and seals must not be cleaned before installation. The door is assembled at VAT in a clean environment and sealed in a plastic bag. Attach the door to a clean system only. Connect compressed air and electrical power only if door is installed into the vacuum system moving parts cannot be touched Do not touch electrical parts under voltage. Admissible forces The dimensions and tolerances specified on the dimensional drawing must be met under all operating conditions. Compressed air connection Compressed air pressure (min. - max. overpressure) : Connections: 4-7 bar / psi Use only clean, dry or slightly oiled air. quick connect fittings for pneumatic tubing O.D. 4 mm without solenoid : connections open (blue) and P (black) on actuator body with solenoid : connection IN for air supply on solenoid mounting block connection EX for exhaust on solenoid mounting block IMPORTANT NOTE: OPEN port must be vented while door is closed and P port must be always pressurized with CDA to endure closing of valve. After installation and after compressed air failure, door command must be set to open before the first closing for proper function of the door. 4/15

5 Pneumatic and electrical connection Socket for solenoid is supplied with door, if equipped with solenoid (ordering code ). Solenoid wiring diagram see label attached to product. Verify that control voltage matches voltage indicated on solenoid. Pneumatic connection Position indicator Subminiatur D connector, 9 pin, male NOTE: Doors without solenoid: wiring is not part of the VAT product and must be setup in customer's system. Doors with solenoid: wiring is part of the VAT product. Recommended flow rate for the solenoid valve is > 150 l/min (at 6 bar). Lo = position indicator open Lg = position indicator close Solenoid for impulse actuation Electrical power may only be connected by an authorized expert! Do not touch parts under voltage! Connect solenoid only when - valve is installed into the vacuum system - moving parts cannot be touched Sockets for solenoid are supplied with the valve. Verify that control voltage matches voltage indicated on the solenoid. Wiring diagram: Solenoid for impulse actuation MV = coil of solenoid Min. pulse duration: 50 ms Pin assignment on the connectors: 5/15

6 Connections on Solenoid for impulse actuation Solenoid Valve to OPEN Solenoid Valve to CLOSE EX Port for Air Connection 1/8 ISO/NPT IN Port for Air Connection 1/8 ISO/NPT Operation Normal operation Door with pneumatic actuator : Door is opened and closed pneumatically. Admissible temperature See chapter «Technical data». Compressed air failure Door closed: Door remains closed for 72 h (integrated check valve). NOTE: Proper check valve function depends on fast air pressure decrease in the pneumatic supply line to the actuator port marked with "P". Slow pressure drop in this line will not trigger the check valve and the door position is undefined at compressed air failure. The check valve only works properly if the following conditions are met for the pneumatic supply line to port "P" between actuator port and T connection as shown in the wiring diagram (see chapter "Pneumatic and electrical connection"): Tubing O.D. Length of pneumatic supply line "P" 4 mm 1.5 m 6 mm 6.0 m Door open: Mounting position actuator downward and sideward: Door remains open. Mounting position actuator upward: undefined IMPORTANT NOTE: After installation and after compressed air failure, door command must be set to open before the first closing for proper function of the door. 6/15

7 Power failure Door supplied with pneumatic connection (ordering code ): Door position depends on applied solenoid valve. VAT recommends to operate all transfer doors with impulse actuated solenoids. Door supplied with impulse solenoid (ordering code ): Door closed: Door remains closed Door open: Door remains open; an already started movement will be completed Emergency operation at power failure In case of power failure, door can be actuated if compressed air is available. To actuate door in case of power failure: To open door: Press push-button on side of port "EX" To close door: Press push-button on side of port "IN" open close Preventive Maintenance The italicized numbers refer to the detail drawings in this chapter and to the drawings in chapter «Spare parts». Under clean operating conditions, the door does not require any maintenance during the specified cycle life (see chapter «Technical data»). Preventive maintenance actions include replacement of the gate seal (or complete gate in case of bonded gate seal) as well as replacement and relubrication of the pneumatic seals according to the detail instruction below. Also, all outer surfaces on the complete door are cleaned. Other parts are checked and replaced if necessary. For repair or case of emergency, VAT recommends to keep at least the following spare parts on site : 1 pc. L-VAT Gate 1 pc. Actuator Service Kit Lubrication of Door Gaskets in the vacuum area are not lubricated. Small amounts of a suitable high vacuum grease (VAT high performance vacuum grease) may be used to lubricate the gate seal Lubricate pneumatic cylinder and piston seals with VAT high temperature pneumatic grease; other lubricants may not meet the VAT cycle life specification Lubricate screws outside the vacuum with Molykote 321R or equivalent; Screws supplied by VAT are lubricated 7/15

8 Cleaning or Replacing L-VAT Gate 1. Vent chambers and command door to the open position 2. Disconnect door from compressed air and electrical supply 3. Remove the 4 set screws 68 on the back of the pressure plate 4. While withdrawing the pressure plate from the shafts make sure that the 2 O-rings 70 stay on the shaft or put them back in position right after removing the plate 5. Loosen the 3 screws 75, and remove L-VAT gate. Never use the old screws again. Attention! Never use the old, used screws 75 again. If a screw is removed it has to be exchanged by a new one with fresh safety coating, otherwise no safe lock is guaranteed. 6. Clean or replace L-VAT gate 7. Use only the new screws supplied with the spare gate or ordered separately (part# ) to reassemble the gate. 8. Before reassembling the L-VAT gate to the pressure plate make sure that all the pistons and washers are at the correct position according to the assembly drawing 9. Tighten the 3 screws 75 with a torque of 9 Nm 10. Before putting the pressure plate back onto the shafts make sure that the 2 O-rings 70 are in the correct position. 11. Tighten the 4 set screws 68 with a torque of 4.5 Nm; These 4 screws have to be tighten step by step, crosswise to similar torque at a step. Make sure that the tips of the set screws fit into the 90 countersunks in the shafts. Recommendation! During system maintenance it is advised to check if the 3 screws 75 are still tightened properly according point 9. 8/15

9 Replacing of actuator pneumatic seals 1. Vent chambers and command door to the open position 2. Disconnect door from compressed air and electrical supply 3. Remove the 4 set screws 68 on the back of the pressure plate (see on page 11) 4. Remove pressure plate assembly from the actuator shafts, also remove the 2 O-rings 70 from the actuator shafts; place these parts in an area where they are protected from contamination and damage 5. Loosen the fixation screws 99 and remove the actuator assembly from the system 6. Remove the 4 roll pins (2 per actuator shaft) and pull the bushing out of the actuator body (see drawing below) Note : Make sue that the bushings do not get damaged during this action. 7. Remove the actuator shafts from the actuator body 8. Remove seals 10, 11, 12, 14, 15, 18 from their position, see drawing below for details 9. Clean and relubricate all grooves for the with step 8 removed seals 10. Put new seals 10, 11, 12, 14, 15, 18 from the Actuator Service Kit in the respective positions 11. Clean and relubricate the pneumatic cylinder walls in the actuator body 12. Reassemble the door in reverse direction Note : Make sure that the 2 O-rings 70 are in the correct position before reassembly of the pressure plate to the actuator shafts 13. Tighten the 3 (Type U) or 4 (Type V) set screws 99 with 6Nm Replacing the position indicator 1. Loosen the two fixation screws which hold the position indicator 42 (see on page 11). 2. Replace the position indicator. 3. Take the two fixation screws to attach the position indicator and tighten them properly. 9/15

10 10/15

11 Spare Parts Attention! VAT has released a retrofit kit in order to provide proper function and safety with the product. This retrofit kit contains 3 pcs. of coated screws (75) and 3 pcs. of washers (61) 4mm thick. Never use old or used screws (75) again. If a screw is removed it has to be exchanged by a new one with fresh safety coating, otherwise no safe lock is guaranteed. If your product is already equipped with washers (61) of 4mm thickness you need to exchange the gate fixation screws (75) with every gate exchange only. Lubricants Description VAT high temperature pneumatic grease (for piston), 12g Ordering no. N Retrofit Kit with spare screws with washers for gate fixation. Description Ordering no. Retrofit kit: contains 3 pcs. coated screws (75) and 3 pcs. washers (61) of 4mm thickness Spare screws for gate fixation Description Countersunk head screw with safety coating (75) Note: 3pcs. are required for 1 valve Ordering no. N Spare gates with vulcanized Viton seal DN Description Ordering No. (Aluminum) Ordering No. (Stainless Steel) 46 x 236 Gate with vulcanized Viton seal x 336 Gate with vulcanized Viton seal Please refer to attention note above! Not indicated sizes, materials, and surface treatments on request Spare gates with assembled O-ring DN Description Ordering No. (Aluminum) Ordering No. (Stainless Steel) 46 x 236 Gate with assembled Viton O-ring x 336 Gate with assembled Viton O-ring Please refer to attention note above! Not indicated sizes, materials, and surface treatments on request Spare O-ring for gate seal DN Description Ordering No. 46 x 236 O-ring Viton N x 236 O-ring Chemraz N x 336 O-ring Viton /15

12 Solenoid Item Description Qty Ordering No. - Solenoid kit (consisting of all parts according to drawing) Specify voltage! Adapter plate Solenoid 24 V/DC (other voltages on request) 1 N Screw (hollow) 2 N Screw 2 N Sealing 2 N Sealing 2 N Actuator assembly, without position indicator and solenoid The item number refers to the drawing on page 13 Item Description Qty. Ordering no. 26 Actuator assembly Position indicator Item Description Qty. Ordering no. 42 Position indicator Position indicator with mounting screws (complete kit) Pressure plate assembly The item numbers refer to the drawing on page 13. Item Description Qty. Ordering no. 60 Pressure plate Washer with countersink Piston shaft Piston Piston 3 N Hex-socket set-screw 4 N O-ring seamless 3 N Countersunk head screw 3 N Actuator installation parts Item Description Qty. Ordering no. 90 O-ring Viton, Type V only 2 N Installation kit, Type U R1 99 Installation kit, Type V R1 12/15

13 Type U Type V 13/15

14 Trouble Shooting Door does not close / open : Power available? Check voltage. Compressed air available? Check air pressure. Solenoid defective? Check solenoid (manual emergency operation). Leak at gate : Dirty? Clean door seat sealing surface and gate. Gate or gate seal damaged? Replace gate O-ring assembly or O-ring if damaged. Seal compression weak? Check air pressure and replace O-ring if necessary. Gate slides along chamber wall: Installation and initial command The correct installation is as follows: 1) move the door into open position 2) attach the door to the chamber 3) connect the air tubing to the "OPEN" port only 4) bend the tubing for the "P" port so that the tube is locked and no CDA (compressed dry air) can leave this tube 5) command the solenoid valve switch to the open position and apply CDA to the "OPEN" port only 6) connect air tubing to the "P" port 7) open the tube for the "P" port and apply CDA to this port 8) command the solenoid valve switch to the close position Compressed air? Check the pressure of the compressed air to be between 4 and 7 bars (55 95 psi). Air tubing? Check the correct length and diameter of the tubing for air supply. See details in chapter Compressed air failure. Air connection? Verify pneumatic connection between solenoid valve and actuator and the correct type of solenoid. Refer to chapter Pneumatic and electronic connection. Repairs Contact VAT for repairs or maintenance. Please advise the serial No. ( /.... ) marked on the actuator. It is individually decided whether the repair can be performed by the customer or has to be carried out by VAT. Disconnect all supplies (e. g. compressed air, electrical power) for removal/installation of the door from/into the system before doing any repair. Even with disconnected supply, loaded springs and/or air cushions in cylinders are potential hazards. Keep fingers and objects away from the door openings! Products returned to VAT for repair have to be free of harmful substances such as e.g. toxic, caustic or micro-biological ones. For radioactive contaminated products fill in the VAT form «Contamination and Radiation Report» and send it with the product. The form is available at VAT. The maximum permissible values indicated in the form must not be exceeded. 14/15

15 Warranty Each product sold by VAT Vakuumventile AG (VAT) is warranted to be free from the manufacturing defects that adversely affect the normal functioning thereof during the one-year period immediately following delivery thereof by VAT, provided that the same is properly operated under conditions of normal use and that regular, periodic maintenance and service is performed or replacements made, in accordance with the instructions provided by VAT. The foregoing warranty shall not apply to any product or component that has been repaired or altered by anyone other than an authorized VAT representative or that has been subject to improper installation or abuse, misuse, negligence or accident. VAT shall not be liable for any damage, loss, or expense, whether consequential, special, incidental, direct or otherwise, caused by, arising out of or connected with the manufacture, delivery (including any delay in or failure to deliver), packaging, storage or use of any product sold or delivered by VAT shall fail to conform to the foregoing warranty or to the description thereof contained herein, the purchaser thereof, as its exclusive remedy, shall upon prompt notice to VAT of any such defect or failure and upon the return of the product, part or component in question to VAT at its factory, with transportation charges prepaid, and upon VAT's inspection confirming the existence of any defect inconsistent with said warranty or any such failure, be entitled to have such defect or failure cured at VAT's factory and at no charge therefor, by replacement or repair of said product, as VAT may elect. VAT MAKES NO WARRANTY OR REPRESENTATION OF ANY KIND, EXPRESS OR IMPLIED, (INCLUDING NO WARRANTY OR MERCHANTABILITY), EXCEPT FOR THE FOREGOING WARRANTY AND THE WARRANTY THAT EACH PRODUCT SHALL CONFORM TO THE DESCRIPTION THEREOF CONTAINED HEREIN, and no warranty shall be implied by law. Furthermore, the «Terms of sale» at the back of the price list are applicable. 15/15

Installation, Operating & Maintenance Instructions. Series 081, DN (I.D. 2½" - 4") Hot surfaces; do not touch!

Installation, Operating & Maintenance Instructions. Series 081, DN (I.D. 2½ - 4) Hot surfaces; do not touch! Vacuum Gate Valve This manual is valid for the valve ordering number(s): 08136-FA14/24/34/44 08138-FA14/24/34/44 08140-FA14/24/34/44 The fabrication number is indicated on each product as per the label

More information

Mini UHV gate valve with manual actuator with pneumatic actuator

Mini UHV gate valve with manual actuator with pneumatic actuator Mini UHV gate valve with manual actuator with pneumatic actuator This manual is valid for the valve ordering numbers: 004/8/3/34-. E0/08 004/8/3/34-. E//3/4 004/8/3/34-. E//3/4 004/8/3/34-. E4/4/34/44

More information

UHV Angle valve (Series 284) with pneumatic actuator, single acting with closing spring (NC)

UHV Angle valve (Series 284) with pneumatic actuator, single acting with closing spring (NC) UHV Angle valve (Series 84) with pneumatic actuator, single acting with closing spring (NC) This manual is valid for the valve ordering number(s): 84 85 The fabrication number is indicated on each product

More information

Installation, Operating & Maintenance Instructions. Hot surfaces; do not touch!

Installation, Operating & Maintenance Instructions. Hot surfaces; do not touch! HV Angle valve (Series 263/265) with manual actuator This manual is valid for the valve ordering number(s): 263/26540-QA/H/E01 263/26544-QA/H/E01 The fabrication number is indicated on each product as

More information

HV Angle valve (Series 264) HV Inline valve (Series 265) with pneumatic actuator, single acting with closing spring (NC)

HV Angle valve (Series 264) HV Inline valve (Series 265) with pneumatic actuator, single acting with closing spring (NC) HV Angle valve (Series 64) HV Inline valve (Series 65) with pneumatic actuator, single acting with closing spring (NC) This manual is valid for the valve ordering number(s): 64 65 The fabrication number

More information

HV-Angle Valve (Series 264) HV-InlineValve (Series 265) with electromagnetic actuator single acting with closing spring (NC)

HV-Angle Valve (Series 264) HV-InlineValve (Series 265) with electromagnetic actuator single acting with closing spring (NC) HV-Angle Valve (Series 264) HV-InlineValve (Series 265) with electromagnetic actuator single acting with closing spring (NC) This manual is valid for the valve ordering number(s): 26... 26428 -K A 61 A..

More information

Control Gate Valve with stepper motor actuator

Control Gate Valve with stepper motor actuator Control Gate Valve with stepper motor actuator This manual is valid for the valve ordering numbers: 64036-.E52 and 64040-.E52 The respective product identification is given on each valve in the following

More information

HV Gate Valve with pneumatic actuator

HV Gate Valve with pneumatic actuator HV Gate Valve with pneumatic actuator This manual is valid for the valve ordering number(s): 09134-_E14/24/34/44 09136-_E14/24/34/44 09138-_E14/24/34/44 09140-_E14/24/34/44 09144-_E14/24/34/44 The fabrication

More information

This manual is valid for the valve ordering numbers: E01/ E01/ E01/ E01/08

This manual is valid for the valve ordering numbers: E01/ E01/ E01/ E01/08 8+9*DWH9DOYH ZLWKPDQXDODFWXDWRU This manual is valid for the valve ordering numbers: 10836-. E01/08 10840-. E01/08 10844-. E01/08 10846-. E01/08 The respective product identification is given on each valve

More information

Installation, Operating & Maintenance Instructions. HV angle valve with pneumatic actuator single acting with closing spring (NC)

Installation, Operating & Maintenance Instructions. HV angle valve with pneumatic actuator single acting with closing spring (NC) Installation, Operating & Maintenance Instructions HV angle valve with pneumatic actuator single acting with closing spring (NC) Series 264 DN 10 50 mm (I. D. ⅜" 2") HV inline valve with pneumatic actuator

More information

HV angle valve with single acting pneumatic actuator and closing spring (NC)

HV angle valve with single acting pneumatic actuator and closing spring (NC) Installation, Operating & Maintenance Instructions HV angle valve with single acting pneumatic actuator and closing spring (NC) Series 264 DN 100 160 mm (I. D. 4 6 ) This manual is valid for the following

More information

Installation, Operating & Maintenance Instructions. UHV gate valve with pneumatic actuator. Series 108 DN mm (I. D. 2½ 8 )

Installation, Operating & Maintenance Instructions. UHV gate valve with pneumatic actuator. Series 108 DN mm (I. D. 2½ 8 ) Installation, Operating & Maintenance Instructions UHV gate valve with pneumatic actuator Series 108 DN 63 200 mm (I. D. 2½ 8 ) This manual is valid for the following product ordering numbers: 108.. -.

More information

Installation, Operating & Maintenance Instructions. HV gate valve with pneumatic actuator. Series 110 DN mm (I. D.

Installation, Operating & Maintenance Instructions. HV gate valve with pneumatic actuator. Series 110 DN mm (I. D. Installation, Operating & Maintenance Instructions HV gate valve with pneumatic actuator Series 110 DN 250 320 mm (I. D. 10" 12") This manual is valid for the following product ordering numbers: 11048-.

More information

Installation, Operating & Maintenance Instructions. All-metal gate valve with compact or extended pneumatic actuator

Installation, Operating & Maintenance Instructions. All-metal gate valve with compact or extended pneumatic actuator Installation, Operating & Maintenance Instructions All-metal gate valve with compact or extended pneumatic actuator Series 48 DN 16 320 mm (I.D. ⅝" 12") This manual is valid for the following product ordering

More information

Installation, Operating & Maintenance Instructions

Installation, Operating & Maintenance Instructions Installation, Operating & Maintenance Instructions Variable leak valve DN 16 (5/8") with integrated controller with Logic interface Series 590 DN 16 mm (I.D. 5/8") This manual is valid for the following

More information

Read this entire manual before operation begins.

Read this entire manual before operation begins. Read this entire manual before operation begins. Record below the following information which is located on the serial number data plate. Serial No. Model No. Date of Installation Contents Specifications.............

More information

Lubricator Gun: 10,000 psi (700 bar) Maximum Delivery Pressure when disconnected from Dispenser

Lubricator Gun: 10,000 psi (700 bar) Maximum Delivery Pressure when disconnected from Dispenser INSTRUCTIONS-PARTS LIST 30 455 INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. Rev. C Supercedes B Hand-Operated Portable Grease Dispenser Buckshot Luber

More information

Power Float Manifold. Installation and Operations Manual Module 11A

Power Float Manifold. Installation and Operations Manual Module 11A Power Float Manifold Installation and Operations Manual Module 11A 2/14 Table of Contents 1 Features 3 2 Functional Purpose 3 3 4 Specifications System Installation 3 4 4.1 Hydraulic Connection 4 4.2 Electric

More information

LUBRICATOR GUN INSTRUCTIONS-PARTS LIST. 10,000 psi (700 bar) Maximum Delivery Pressure. Detachable-type

LUBRICATOR GUN INSTRUCTIONS-PARTS LIST. 10,000 psi (700 bar) Maximum Delivery Pressure. Detachable-type INSTRUCTIONS-PARTS LIST 306 460 INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. Rev. E Supercedes D Detachable-type LUBRICATOR GUN 10,000 psi (700 bar)

More information

Read this entire manual before operation begins.

Read this entire manual before operation begins. Read this entire manual before operation begins. Record below the following information which is located on the serial number data plate. Serial No. Model No. Date of Installation Contents Specifications.............

More information

Single-Position Detent Clutch DC Series. (i) MTY (81) MEX (55) QRO (442)

Single-Position Detent Clutch DC Series. (i) MTY (81) MEX (55) QRO (442) Single-Position Detent Clutch DC Series (i) FORM NO. L-2017-A-001 In accordance with Nexen s established policy of constant product improvement, the specifications contained in this manual are subject

More information

- C8. SINGLE AND MANIFOLD TYPE INJECTORS for dispensing fluid lubricants and greases not exceeding Lincoln ventmeter viscosity of 600 psi.

- C8. SINGLE AND MANIFOLD TYPE INJECTORS for dispensing fluid lubricants and greases not exceeding Lincoln ventmeter viscosity of 600 psi. SINGLE AND MANIFOLD TYPE INJECTORS for dispensing fluid lubricants and greases not exceeding Lincoln ventmeter viscosity of 600 psi. SPECIFICATIONS Minimum operating pressure 1850 psi [128 bar] Maximum

More information

Straight-Bore Clutch LSCC-32, 44, 54

Straight-Bore Clutch LSCC-32, 44, 54 Straight-Bore Clutch LSCC-32, 44, 54 1 In accordance with Nexen s established policy of constant product improvement, the specifications contained in this manual are subject to change without notice. Technical

More information

INSTALLATION AND MAINTENANCE MANUAL FORM #PM-126 REV A 12/09

INSTALLATION AND MAINTENANCE MANUAL FORM #PM-126 REV A 12/09 HAND CRANK & MOTORIZED POWER CORD REELS: SERIES 1125PC SERIES: 1125PC HAND CRANK SERIES: 1125PC MOTORIZED COXREELS The technical data and images which appear in this manual are for informational purposes

More information

Pneumatic Single Disc and Dual Disc Brakes P250 and P620

Pneumatic Single Disc and Dual Disc Brakes P250 and P620 P-208-WE SM318-gb-02/09 Pneumatic Single Disc and Dual Disc Brakes P20 and P20 Service Manual We, WARNER ELECTRIC EUROPE,, rue Champfleur, B.P. 2009, F-49182 St Barthélemy d Anjou Cedex declare that the

More information

Model CP470. Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual

Model CP470. Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual Model Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual CP470 Updated 06/17 Contents: Installation Instructions: page 2 Pump Specifications: page 3 Exploded View: page 4 Part

More information

INSTALLATION AND MAINTENANCE MANUAL FORM #PM-122 REV A 12/09

INSTALLATION AND MAINTENANCE MANUAL FORM #PM-122 REV A 12/09 HAND CRANK WELDING CABLE REEL: SERIES 100WC COXREELS The technical data and images which appear in this manual are for informational purposes only. NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WARRANTIES

More information

p.t.o. Slip clutch Read this material before using this product. Failure to do so can result in serious injury. Save this manual.

p.t.o. Slip clutch Read this material before using this product. Failure to do so can result in serious injury. Save this manual. p.t.o. Slip clutch 65517 Installation Instructions Distributed exclusively by Harbor Freight Tools. 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our website at: http://www.harborfreight.com Read

More information

MODEL 5120 Tire Repair Station

MODEL 5120 Tire Repair Station MODEL 5120 Tire Repair Station 00-0049 Installation, Operation & Repair Parts Information Branick Industries, Inc. 4245 Main Avenue P.O. Box 1937 Fargo, North Dakota 58103 REV01182017 P/N: 81-0058G CAUTION

More information

PUSH BUTTON KEY CABINET

PUSH BUTTON KEY CABINET PUSH BUTTON KEY CABINET Model 95689 INSTALLATION And Operation Instructions Due to continuing improvements, actual product may differ slightly from the product described herein. 3491 Mission Oaks Blvd.,

More information

DeZURIK 2-24 (50-600mm) KGN-RSB BI-DIRECTIONAL CAST STAINLESS STEEL KNIFE GATE VALVES

DeZURIK 2-24 (50-600mm) KGN-RSB BI-DIRECTIONAL CAST STAINLESS STEEL KNIFE GATE VALVES 2-24 (50-600mm) KGN-RSB BI-DIRECTIONAL CAST STAINLESS STEEL KNIFE GATE VALVES Instruction D11023 October 2016 Instructions These instructions provide information about KGN-RSB Knife Gate Valves. They are

More information

4-Ton Electric Log Splitter

4-Ton Electric Log Splitter 4-Ton Electric Log Splitter Questions: Support@Powrkraft.com PK65556 2 18ga. @ 20ft, 16ga. @ 50ft, 14 ga. @ 75ft. 12ga @ 100ft, 10ga @ 200ft These are minimum cord requirements. 13-16 Model Number 65556

More information

Butterfly control & isolation valve with extended control range with Logic interface

Butterfly control & isolation valve with extended control range with Logic interface Butterfly control & isolation valve with extended control range with Logic interface This manual is valid for the valve ordering number(s): 615.. -.. GC -.... (1 sensor input) 615.. -.. GE -.... (2 sensor

More information

DAP-625S and DAP-875S

DAP-625S and DAP-875S AIR CHAMP PRODUCTS DAP-625S and DAP-875S (i) FORM NO. L-20078-B-0501 In accordance with Nexen s established policy of constant product improvement, the specifications contained in this manual are subject

More information

Owner s Manual & Safety Instructions

Owner s Manual & Safety Instructions Owner s Manual & Safety Instructions Save Save This This Manual Keep Keep this this manual manual for for the the safety safety warnings warnings and and precautions, assembly, assembly, operating, inspection,

More information

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

CLEAN ROOM DEVICES, LLC WHERE TUBING AND FITTINGS COME TOGETHER CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER" CRD400 Fitting Inserter OPERATIONS MANUAL VERSION 3.1 LAST EDITED 03.08.11 DOCUMENT NUMBER 001 cleanroomdevices.com 1 Table of Contents

More information

OWNER S GUIDE 8A DURALIFT II 13,200 LB. CAPACITY. Link Mfg. Ltd th St. N.E. Sioux Center, IA USA

OWNER S GUIDE 8A DURALIFT II 13,200 LB. CAPACITY. Link Mfg. Ltd th St. N.E. Sioux Center, IA USA OWNER S GUIDE 8A000715 DURALIFT II 13,200 LB. CAPACITY Link Mfg. Ltd. 223 15th St. N.E. Sioux Center, IA USA 51250-2120 www.linkmfg.com QUESTIONS? CALL CUSTOMER SERVICE 1-800-222-6283 DEALER / INSTALLER:

More information

Through-Shaft Clutch-Brake LSCB-32HT, LSCB-32HT, LSCB-44, LSCB-44HT, LSCB-54HT FORM NO. L D-0606 MEX (55) QRO (442)

Through-Shaft Clutch-Brake LSCB-32HT, LSCB-32HT, LSCB-44, LSCB-44HT, LSCB-54HT FORM NO. L D-0606 MEX (55) QRO (442) Through-Shaft Clutch-Brake LSCB-HT, LSCB-HT, LSCB-, LSCB-HT, LSCB-5HT In accordance with Nexen s established policy of constant product improvement, the specifications contained in this manual are subject

More information

Owner s Manual & Safety Instructions

Owner s Manual & Safety Instructions Owner s Manual & Safety Instructions Save This Manual Keep this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and cleaning procedures. Write the product s

More information

CRD600 Automatic Fitting Inserter

CRD600 Automatic Fitting Inserter CRD600 Automatic Fitting Inserter OPERATIONS MANUAL VERSION 2.3 LAST EDITED 12.07.2018 cleanroomdevices.com 1 Table of Contents Title Page.. 1 Table of Contents. 2 1.0 General Product & Safety Information...3

More information

Model No , -2, -3, -4, -5, , , -2, -3, -4, -5, and SL-V INJECTOR Series A

Model No , -2, -3, -4, -5, , , -2, -3, -4, -5, and SL-V INJECTOR Series A 8578 and 85782 Series A SINGLE AND MANIFOLD TYPE INJECTORS for dispensing fluid lubricants and greases not exceeding Lincoln ventmeter viscosity of 600 psi. SPECIFICATIONS Minimum operating pressure 850

More information

Manufacturing Facility is ISO9001:2000. Welded Steel Pipe Conform to ASTM A53. Threads Conform to ASME B1.20.1

Manufacturing Facility is ISO9001:2000. Welded Steel Pipe Conform to ASTM A53. Threads Conform to ASME B1.20.1 STEEL NIPPLES S40 & S80 Steel Nipple Product Specifications Manufacturing Facility is ISO9001:2000 Welded Steel Pipe Conform to ASTM A53 Threads Conform to ASME B1.20.1 800-678-2544 800-678-0857 www.msi-products.com

More information

DeZURIK 2 20" BOS BUTTERFLY VALVES

DeZURIK 2 20 BOS BUTTERFLY VALVES 2 20" BOS BUTTERFLY VALVES Instruction D10459 October 2013 2-20 BOS Butterfly Valves Instructions These instructions provide information about BOS Butterfly Valves. They are for use by personnel who are

More information

IMPORTANT SAFETY INFORMATION

IMPORTANT SAFETY INFORMATION Specifications Tricycle Height 26 Front Wheel 5/8 Axle Diameter, 13 Pneumatic Knobby Tire Back Wheels 5/8 Axle Diameter, 10 Pneumatic Knobby Tire Age Range 5 and up Weight Capacity 150 lb. IMPORTANT SAFETY

More information

Read this entire manual before operation begins.

Read this entire manual before operation begins. Read this entire manual before operation begins. Record below the following information which is located on the serial number data plate. Serial No. Model No. Date of Installation Contents Specifications.............

More information

1.0 Introduction Mounting Procedure Verifying Calibration Accuracy Specifications Tension Ranges...

1.0 Introduction Mounting Procedure Verifying Calibration Accuracy Specifications Tension Ranges... 5.0 WARRANTY ELECTROMATIC Equipment Co., Inc. (ELECTROMATIC) warrants to the original purchaser that this product is of merchantable quality and confirms in kind and quality with the descriptions and specifications

More information

STAINLESS STEEL FORGED FITTINGS 3000lb 304/304L & 316/316L Forged Stainless Steel Fittings Product Specifications

STAINLESS STEEL FORGED FITTINGS 3000lb 304/304L & 316/316L Forged Stainless Steel Fittings Product Specifications STAINLESS STEEL FORGED FITTINGS 3000lb 304/304L & 316/316L Forged Stainless Steel Fittings Product Specifications Manufactured in ISO9000:2000 Facility Manufactured to ASTM/ASME A182/SA182 Items conform

More information

CRD610 Automatic Fitting Inserter

CRD610 Automatic Fitting Inserter CRD610 Automatic Fitting Inserter OPERATIONS MANUAL VERSION 1.2 LAST EDITED 12.12.2018 cleanroomdevices.com 1 Table of Contents Title Page. 1 Table of Contents...2 1.0 General Product & Safety Information....3

More information

TK08 TUNING KIT TECHNICAL MANUAL FOR 16/26/27/28 SERIES SHOCKS Revised 6/25/14 Tech Line: (952) Fax (952)

TK08 TUNING KIT TECHNICAL MANUAL FOR 16/26/27/28 SERIES SHOCKS Revised 6/25/14 Tech Line: (952) Fax (952) Tech Line: (952) 985-5675 Fax (952) 985-5679 21730 Hanover Ave. Lakeville, MN 55044 www.qa1.net www.facebook.com/qa1motorsports TK08 TUNING KIT TECHNICAL MANUAL CONTENTS UNDER PRESSURE! USE EXTREME CAUTION

More information

BC Brake Caliper. (i) MEX (55) QRO (442) MTY (81) DIST. AUTORIZADO

BC Brake Caliper. (i) MEX (55) QRO (442) MTY (81) DIST. AUTORIZADO MEX (55) 5 6 QRO (44) 95 7 60 MTY () 54 0 BC Brake Caliper (i) FORM NO. L-0066-B-040 In accordance with Nexen s established policy of constant product improvement, the specifications contained in this

More information

CAUTION 7.0 WARRANTY CONTENTS. 1.0 Overview... 2

CAUTION 7.0 WARRANTY CONTENTS. 1.0 Overview... 2 7.0 WARRANTY ELECTROMATIC Equipment Co., Inc. (ELECTROMATIC) warrants to the original purchaser that this product is of merchantable quality and confirms in kind and quality with the descriptions and specifications

More information

PLEASE ENSURE THE JUMP STARTER IS FULLY CHARGED PRIOR TO FIRST USE.

PLEASE ENSURE THE JUMP STARTER IS FULLY CHARGED PRIOR TO FIRST USE. PLEASE ENSURE THE JUMP STARTER IS FULLY CHARGED PRIOR TO FIRST USE.. (1) RG1000 EMERGENCY JUMP STARTER PORTABLE POWER SUPPLY (1) 3-IN-1 USB CABLE (1) RG1000 EMERGENCY JUMP STARTER PORTABLE POWER SUPPLY

More information

Model AS-FM64 Wall Mount. Full Motion Television Wall Mount

Model AS-FM64 Wall Mount. Full Motion Television Wall Mount Model AS-FM64 Wall Mount Full Motion Television Wall Mount Getting Started Introduction Congratulations on the purchase of your new Audio Solutions AS-FM64 Television Wall Mount. For maximum benefit, please

More information

MULTIPOSITION AIR CYLINDER

MULTIPOSITION AIR CYLINDER MULTIPOSITION AIR CYLINDER CAST ALUMINUM FOUR-POSITION - ALL AIR SERVICE INFORMATION MOUNTING! Devices should be mounted and positioned in such a manner that they cannot be accidentally operated. INSTALLATION

More information

Elgin Hydraulic Clutch-Brake ECB-240, Product Number FORM NO. L F FORM NO. L F-0704

Elgin Hydraulic Clutch-Brake ECB-240, Product Number FORM NO. L F FORM NO. L F-0704 Elgin Hydraulic Clutch-Brake ECB-20, Product Number 96225 FORM NO. L-20283-F-070 1 FORM NO. L-20283-F-070 In accordance with Nexen s established policy of constant product improvement, the specifications

More information

DRVRMDMOTL Motorized Linear Drive. DRVMDMOTLR Motorized Linear and Rotary Drive. Instruction Manual

DRVRMDMOTL Motorized Linear Drive. DRVMDMOTLR Motorized Linear and Rotary Drive. Instruction Manual DRVRMDMOTL Motorized Linear Drive DRVMDMOTLR Motorized Linear and Rotary Drive Instruction Manual Version 1.1 07 November 2016 Thurgauerstr. 72, CH-8050 Zürich, Switzerland TEL. +41 44 273 16 38, FAX.

More information

CAMBELT TENSION GAUGE

CAMBELT TENSION GAUGE CAMBELT TENSION GAUGE Model 96557 Operating Instructions Diagrams within this manual may not be drawn proportionally. Due to continuing improvements, actual product may differ slightly from the product

More information

Nor East. Instructions Safety Messages. Inspection. Parts. DeZURIK Service. Type 05 Pneumatic Actuator Used With Globe Valves

Nor East. Instructions Safety Messages. Inspection. Parts. DeZURIK Service. Type 05 Pneumatic Actuator Used With Globe Valves Instructions Safety Messages These instructions are intended for personnel who are responsible for installation, operation and maintenance of your DeZURIK Actuator. All safety messages in the instructions

More information

Smoke Leak Locator. User Manual. For Models: Pro S 25, Pro S 75, Pro S 500T, Pro S 600T, Pro S 1000HD. Ceramic Heating Technology

Smoke Leak Locator. User Manual. For Models: Pro S 25, Pro S 75, Pro S 500T, Pro S 600T, Pro S 1000HD. Ceramic Heating Technology Smoke Leak Locator User Manual For Models: Pro S 25, Pro S 75, Pro S 500T, Pro S 600T, Pro S 1000HD Ceramic Heating Technology www.proflex-plus.com All models come with a User Manual, Quick Start Guide,

More information

Swing Arm Magnifying Lamp

Swing Arm Magnifying Lamp Owner s Manual & Safety Instructions Save This Manual Keep this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and cleaning procedures. Write the product s

More information

Model FM2642 Wall Mount. Full Motion Television Wall Mount

Model FM2642 Wall Mount. Full Motion Television Wall Mount Model FM2642 Wall Mount Full Motion Television Wall Mount Getting Started Introduction Congratulations on the purchase of your new Audio Solutions FM2642 Television Wall Mount. For maximum benefit, please

More information

END USER TERMS OF USE

END USER TERMS OF USE END USER TERMS OF USE The following is the End Users Terms of Use as it currently appears in the Mobileye User Manual and Warranty information. This is here for your review and information; it is subject

More information

6.0 SPECIFICATIONS CONTENTS. Calibration. According to factory procedureeeeeeeeeeeeeee Accuracy*

6.0 SPECIFICATIONS CONTENTS. Calibration. According to factory procedureeeeeeeeeeeeeee Accuracy* 6.0 SPECIFICATIONS Calibration According to factory procedureeeeeeeeeeeeeee Accuracy* ± 1% full scale (FS) or ± 1 graduation on scale Scale diameter 41 mm Temperature range 45 to 115 F (10-45 C) Air humidity

More information

Model:M5B/M5W/M5N. Installation Guide. Specifications Desktop Weight Capacity Keyboard Tray Weight Capacity Height Adjustable Range

Model:M5B/M5W/M5N. Installation Guide. Specifications Desktop Weight Capacity Keyboard Tray Weight Capacity Height Adjustable Range Model:M5B/M5W/M5N Installation Guide Website: www.flexispot.com Tel: 1-855-421-2808 Specifications Desktop Weight Capacity Keyboard Tray Weight Capacity Height Adjustable Range 33 Ibs (15 KG) 4.4 Ibs (2

More information

TK08 TUNING KIT TECHNICAL MANUAL FOR 16/26/27/28 SERIES SHOCKS Revised 6/17/14

TK08 TUNING KIT TECHNICAL MANUAL FOR 16/26/27/28 SERIES SHOCKS Revised 6/17/14 Tech Line: (952) 985-5675 Fax (952) 985-5679 21730 Hanover Ave. Lakeville, MN 55044 www.qa1.net www.facebook.com/qa1motorsports TK08 TUNING KIT TECHNICAL MANUAL CONTENTS UNDER PRESSURE! USE EXTREME CAUTION

More information

6 OFF ROAD LIGHT BAR

6 OFF ROAD LIGHT BAR 6 OFF ROAD LIGHT BAR LOUD speaker Model 95953 Set up And Operating Instructions Diagrams within this manual may not be drawn proportionally. Due to continuing improvements, actual product may differ slightly

More information

SeeDOS Product User Manual Seed Slider

SeeDOS Product User Manual Seed Slider Seed Slider Table of Contents Subject Page General Precautions... 2 Customer Responsibility... 2 Features & Specifications... 3 Description... 3 Operation... 4 Maintenance... 7 Service... 7 Parts and Accessories...

More information

<< FEATURES AND BENEFITS >>

<< FEATURES AND BENEFITS >> PISTOL SLIDE MANUAL TABLE OF CONTENTS FEATURES AND BENEFITS... 2 ASSEMBLY AND INSTALLATION...3-4 INSTALLING TRIJICON RMR PLATE... 5 IMPORTANT SAFETY INFORMATION... 6 LIMITED WARRANTY... 7-10

More information

Model AS-RC3260 TV Cart. Rolling Cart for Audio Mount System & Flat Panel TVs

Model AS-RC3260 TV Cart. Rolling Cart for Audio Mount System & Flat Panel TVs Model AS-RC3260 TV Cart Rolling Cart for Audio Mount System & Flat Panel TVs GETTING STARTED Introduction Congratulations on the purchase of your new Helios AS-RC3260 Rolling Cart. For maximum benefit,

More information

Read this entire manual before operation begins.

Read this entire manual before operation begins. Read this entire manual before operation begins. Record below the following information which is located on the serial number data plate. Serial No. Model No. Date of Installation Contents Specifications.............

More information

iqpc912 PARTS MANUAL PC912PM v1

iqpc912 PARTS MANUAL PC912PM v1 iqpc912 PARTS MANUAL PC912PM v1 See Page 10 See Page 6 & See Page 12 See Page 2 See Page 16 See Page 1 See Page 1 See Page See Page 22 See Page 20 See Page 2 See Page 26 3 16 19 1 17 1 1 11 13 12 10 9

More information

Model T2642 Wall Mount. Television Wall Mount with Tilt Option

Model T2642 Wall Mount. Television Wall Mount with Tilt Option Model T2642 Wall Mount Television Wall Mount with Tilt Option Getting Started Introduction Congratulations on the purchase of your new Audio Solutions T2642 Television Wall Mount. For maximum benefit,

More information

Gen 2 Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB

Gen 2 Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB Gen 2 Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB P-273-8 819-0531 Installation Instructions Vented Enclosed Version Optional An Altra Industrial Motion Company Warner Electric s

More information

Adjustable Shop Stool with Backrest

Adjustable Shop Stool with Backrest Adjustable Shop Stool with Backrest Owner s Manual WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety

More information

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

CLEAN ROOM DEVICES, LLC WHERE TUBING AND FITTINGS COME TOGETHER CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER" CRD600 Automatic Fitting Inserter OPERATIONS MANUAL VERSION 2.1 LAST EDITED 7.25.14 DOCUMENT NUMBER 001 cleanroomdevices.com 1 Table of

More information

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES Instruction D12043 June 2016 DeZURIK Instructions These instructions provide installation, operation and maintenance information for APCO CRF-100A Rubber

More information

CRD400 Fitting Inserter OPERATIONS MANUAL

CRD400 Fitting Inserter OPERATIONS MANUAL CRD400 Fitting Inserter OPERATIONS MANUAL ORIGINAL INSTRUCTIONS VERSION 3.4 LAST EDITED 01.07.2019 www.cleanroomdevices.com 1 Table of Contents Title Page.. 1 Table of Contents... 2 1.0 General Product

More information

Spin Klin 3"-4" Apollo Angle

Spin Klin 3-4 Apollo Angle Spin Klin 3"-4" Apollo Angle w w w. a r k a l - f i l t e r s. c o m 3"-4" Spin Klin Angle Apollo Battery Service & Maintenance Manual Table of Contents Subject Page No. 1. Introduction... 3 2. Safety

More information

1250 LB. CAPACITY MECHANICAL WHEEL DOLLY

1250 LB. CAPACITY MECHANICAL WHEEL DOLLY 1250 LB. CAPACITY MECHANICAL WHEEL DOLLY 67287 SET-UP AND OPERATING INSTRUCTIONS Visit our website at: http://www.harborfreight.com Read this material before using this product. Failure to do so can result

More information

HP30 Slab Saw Owner s Manual and Operating Instructions

HP30 Slab Saw Owner s Manual and Operating Instructions HP30 Slab Saw Owner s Manual and Operating Instructions MADE IN USA Revision 07 09.0 Manual Part No. 67 Caution: Read all safety and operating instructions before using this equipment. This manual MUST

More information

203 TRANSFER CASE CONVERSION

203 TRANSFER CASE CONVERSION 203 TRANSFER CASE CONVERSION PN:501 OUR FOUR TRANSFER CASE WEDGES REPLACE THE SPIDER GEARS AND CONNECT THE PLANETARY GEAR AND REAR OUTPUT SHAFT MAKING ONE UNIT. SIMILAR IN DESIGN & FUNCTION TO THE BEST

More information

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES APCO ASR-400/450 SEWAGE AIR RELEASE VALVES Instruction D12005 December 2012 Instructions These instructions provide installation, operation and maintenance information for the APCO ASR- 400/450 Sewage

More information

Operating Instructions and Parts Manual SLT-330F Scissor Lift Table

Operating Instructions and Parts Manual SLT-330F Scissor Lift Table Operating Instructions and Parts Manual SLT-330F Scissor Lift Table For serial no. 17020001 and higher JET 427 New Sanford Road LaVergne, Tennessee 37086 Part No. M-140771 Ph.: 800-274-6848 Revision C

More information

SFA275 USER MANUAL PLEASE READ THIS USER MANUAL COMPLETELY BEFORE OPERATING THIS UNIT AND RETAIN THIS BOOKLET FOR FUTURE REFERENCE

SFA275 USER MANUAL PLEASE READ THIS USER MANUAL COMPLETELY BEFORE OPERATING THIS UNIT AND RETAIN THIS BOOKLET FOR FUTURE REFERENCE Parking Alert Sensor SFA275 USER MANUAL PLEASE READ THIS USER MANUAL COMPLETELY BEFORE OPERATING THIS UNIT AND RETAIN THIS BOOKLET FOR FUTURE REFERENCE COMPLIANCE WITH FCC REGULATIONS This device complies

More information

Pro Shot Grease Dispense Valve

Pro Shot Grease Dispense Valve Instructions Parts List Pro Shot Grease Dispense Valve 309032J For high pressure grease dispense. 8000 psi (55 MPa, 552 bar) Maximum Working Pressure Model No. 242055, Series B, 1/4 npt Fluid Inlet Model

More information

Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB Size 50, 100, 180

Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB Size 50, 100, 180 Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB Size 50, 100, 180 P-273-8-WE 819-0531 Installation Instructions Vented Enclosed Version Optional Warner Electric s MBFB series of Electrically

More information

4" Spin Klin Twin Apollo Battery. Service & Maintenance Manual

4 Spin Klin Twin Apollo Battery. Service & Maintenance Manual 4" Spin Klin Twin Apollo Battery Service & Maintenance Manual Table of Contents Subject Page No. 1. Introduction... 3 2. Safety Instructions... 3 3. Description and Operation... 4 4. Technical Data...

More information

Spin Klin 4" Apollo Twin

Spin Klin 4 Apollo Twin Spin Klin 4" Apollo Twin w w w. a r k a l - f i l t e r s. c o m 4" Spin Klin Twin Apollo Battery Service & Maintenance Manual Table of Contents Subject Page No. 1. Introduction... 3 2. Safety Instructions...

More information

LU27 Series Quick Start

LU27 Series Quick Start Ultrasonic Liquid Level Transmitter LU27 Series Quick Start 2016 Flowline, Inc. All Rights Reserved Made in USA Flowline, Inc. 10500 Humbolt Street, Los Alamitos, CA 90720 p 562.598.3015 f 562.431.8507

More information

ORIGINAL INSTRUCTIONS G715A. Pneumatic-hydraulic Riveter E. Warner Ave Santa Ana, CA

ORIGINAL INSTRUCTIONS G715A. Pneumatic-hydraulic Riveter E. Warner Ave Santa Ana, CA ORIGINAL INSTRUCTIONS G715A Pneumatic-hydraulic Riveter 1224 E. Warner Ave Santa Ana, CA 92705 www.cherryaerospace.com DESCRIPTION The Cherry G715A Pneumatic-Hydraulic Riveter is designed specifically

More information

DeZURIK KUL KNIFE GATE VALVES

DeZURIK KUL KNIFE GATE VALVES KUL KNIFE GATE VALVES Instruction D11025 September 2013 Instructions These instructions are intended for personnel who are responsible for the installation, operation and maintenance of your KUL knife

More information

Atlas PV-9WP Addendum

Atlas PV-9WP Addendum Atlas PV-9WP Addendum 9,000 lb. Capacity Two-Post Overhead Lift The Atlas PV-9WP above ground hoist is 6 inches wider than the Atlas PV-9P, giving it an overall width of 141 (11 9 ) and a drive thru width

More information

7.3L POWERSTROKE BANJO BOLT KIT Fits L Powerstroke Diesel. Installation Guide

7.3L POWERSTROKE BANJO BOLT KIT Fits L Powerstroke Diesel. Installation Guide 7.3L POWERSTROKE BANJO BOLT KIT Fits 94-03 7.3L Powerstroke Diesel Installation Guide INSPECT CONTENTS OF THIS KIT THOROUGHLY BEFORE STARTING THE INSTALLATION PROCESS! IF YOU FIND A PROBLEM WITH YOUR PACKAGE:

More information

CAUTION CONTENTS 5.0 WARRANTY

CAUTION CONTENTS 5.0 WARRANTY 5.0 WARRANTY ELECTROMATIC Equipment Co., Inc. (ELECTROMATIC) warrants to the original purchaser that this product is of merchantable quality and confirms in kind and quality with the descriptions and specifications

More information

Read this entire manual before operation begins.

Read this entire manual before operation begins. Read this entire manual before operation begins. Record below the following information which is located on the serial number data plate. Serial No. Model No. Date of Installation Contents Specifications.............

More information

Owner s Manual Supplement. Liquefied Petroleum Gas (LPG) Fuel System for 1998 GM Medium Duty Chassis (C-60/C-70) with 6.0L and 7.

Owner s Manual Supplement. Liquefied Petroleum Gas (LPG) Fuel System for 1998 GM Medium Duty Chassis (C-60/C-70) with 6.0L and 7. Owner s Manual Supplement Liquefied Petroleum Gas (LPG) Fuel System for 1998 GM Medium Duty Chassis (C-60/C-70) with 6.0L and 7.0L V8 OWNERS MANUAL SUPPLEMENT Table of Contents Refueling Your Vehicle...1

More information

PCC O P E R A T I O N S. Pump Cycle Counter M A N U A L. Environmental Systems

PCC O P E R A T I O N S. Pump Cycle Counter M A N U A L. Environmental Systems O P E R A T I O N S Environmental Systems PCC Pump Cycle Counter M A N U A L PO Box 3726 Ann Arbor, Michigan 48106-3726 (800) 624-2026 North America Only (734) 995-2547 Tele. (734) 995-1170 Fax info@qedenv.com

More information

JD-2 TOLL FREE UG August /2011

JD-2 TOLL FREE UG August /2011 Instructions Manual Office Phone: 1-800-503-7534 / 305-868-1603 Fax: 305-866-2704 sales@skyfood.us - www.skyfood.us Warehouse Phone: 1-800-445-6601 / 973-482-5070 Fax: 973-482-0725 Juice Dispenser Model

More information

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables PVI 1800/PVI 2500 WARRANTY MANUAL Residential/Commercial Grid-Tied Photovoltaic Inverter 2009, Solectria Renewables Subject to Change REV 10.09 1 Product Warranty & RMA Policy 1.1 Warranty Policy The Solectria

More information

JOHN DEERE 9970 COTTON PICKERS

JOHN DEERE 9970 COTTON PICKERS PARTS CATALOG FOR Mud Hog System II Rear Wheel Drive FOR JOHN DEERE 9970 COTTON PICKERS Mud Hog Model Numbers Tread Center OEM Aftermarket JD40005 JD47655 82, 90, 94, 106 TUTHILL Drive Systems 9098 West

More information