ASSEMBLING THE 15 INCH FLUSH MOUNT TOUCH SCREEN DIMENSIONS OF THE 15 INCH FLUSH MOUNT TOUCH SCREEN
|
|
- Mitchell Jordan
- 5 years ago
- Views:
Transcription
1 DIMENSIONS OF THE 15 INCH FLUSH MOUNT TOUCH SCREEN 18 (457 mm) 12 39/64 (320 mm) 3 1/2 (89 mm) 1 13/32 (36 mm) 19 (483 mm) 3 5/8 (92 mm) 7/64 3 mm) 1 13/32 (36 mm) 23 53/64 (605 mm) 20 3/4 (527 mm) 12 3/4 (324 mm) 13 13/16 (351 mm) 21 7/32 (539 mm) 7/32 (6 mm) 7/32 (5 mm) 1 13/64 (30 mm) 26 13/64 (665 mm) 21 7/32 (539 mm) 2 53/64 (72 mm) 2 1/5 (64 mm) 2 1/5 (64 mm) Figure 1: Dimensions of the 15 Flush Mount Touch Screen A complete library of product information is available at: Mircom July 2015 Printed in Canada Subject to change without prior notice LT-6105 rev 1.1 Page 1 of 6
2 1 MOUNT THE ENCLOSURE 2 The surface mount enclosure mounts on the wall. Mount the enclosure right-side up (the Mircom logo on the door is on the bottom). You need: 6 fasteners appropriate for the wall that you are mounting the enclosure on. Keyhole Keyhole 1. Find a suitable location for the enclosure. You can mount the enclosure using the keyholes on the back, or the knockouts on the side, or both. 2. Using the enclosure as a template, trace an opening in the wall for the cutout with one side is aligned with the side of the wall stud. 3. Cut an opening in the wall 0.1 inch larger than the trace ensuring that one side is aligned with the wall stud or supporting structure. 4. Insert the enclosure into the wall cutout and using the side of the enclosure as a template mark the hole mounting locations (either keyholes or knockouts or both). 5. If you are using the keyholes, remove the enclosure and place 2 fasteners halfway into the wall into the marked keyhole locations. Then place the enclosure onto the top fasteners and lower it so that the fasteners fit in the narrow part of the keyholes. 6. Screw the other fasteners into the remaining holes or knockouts. 7. Tighten all fasteners into place. Figure 3: Front View Wall Frame Top Enclosure Figure 2: Location of the mounting holes Front Side View Figure 4: Side View LT-6105 rev 1.1 Page 2 of 6
3 Power Switch (on outside of door) AC or DC Door Strikes: Auxiliary Door Strike: 21 and 3 AC Door Strike or Maglock AWG 3 NO NC Jumper JW8 Jumper JW8 NO NC TS8 AC Door Strike or Magnetic Lock AC or DC Power Supply for Door Strike For a door strike: connect the jumper wire to the top pin of jumper JW8 (normally open). AC or DC Power Supply for Door Strike TS8 DC Door Strike (Output 1) 18 AWG DC Output Door Strike or Magnetic Lock TS9 4 Auxiliary Door (Output 2) 18 AWG For a maglock: connect the jumper wire to the bottom pin of jumper JW8 (normally closed). The maximum supply for the AC or DC Power Supply for Door Strike must not exceed: 28 VAC / 1 A max 30 VDC / 1 A max Alternative Wiring for Dry Contact Warning: Turn the power off before wiring. Wiring Requirements Install all power supplies outside the enclosure. Unless specified otherwise, all wiring is a maximum length of 1000 ft (304.8 m). The RS-485 wiring maximum length is 4000 ft ( m). See LT-996 for power wiring lengths. The door strike power supply depends on the door strike power requirements. On/Off Switch TS9 - + Door Strike Note: Most door strikes are nonpolarity. + - Power Supply Note: If AC power supply is used, polarity does not apply. Jumper JW8 NO NC TS8 Trigger for door operator Jumper JW8 controls whether the contact is normally open or normally closed. Contact ratings for outputs 2-4: 125 VAC / 2 A 30 VDC / 1 A LT-6105 rev 1.1 Page 3 of 6
4 Camera Supply Address 1 DIP SWITCH SETTINGS FOR RS-485 Address 2 Address 3 Address 4 ON OFF Each Touch Screen must have a unique RS-485 address. Use DIP switches 1-6 to set the RS-485 network address. See LT-969 for details. Phone Lines: 8 SW1 DIP Switches TS3 Camera Power Supply (12 VDC) Phone Lines Line 1 T R T R Line 2 (optional) P7 Guard Phone board connector P5 TX3-IP Module Connection P4 TX3-MDM Modem board connector 7 Postal Lock (Input 1) Fire Alarm Override (Input 2) Door Contact (Input 3) 22 AWG Non-configurable PBX systems are not supported. For more information, contact Mircom technical support at Warning: Turn the power off before wiring. USB connector: Connect to computer for firmware upgrade and configuration (maximum length of USB cable: 8 ft/2.4 m) Postal Lock: RS-485: On/Off Switch Camera Supply: TS5 Postal Lock Warning: Do not attach the wiring until after the postal lock is installed. Fire Panel Activation of this input Door relocks the main door Contact (Output 1). Activation of this input unlocks the main and auxiliary doors (Outputs 1 and 2). LT-6105 rev 1.1 Page 4 of 6
5 9 RS GROUND 22 AWG Maximum length: 4000 ft ( m) Panel 1 First panel on network Panel 2 Panel 3 Last panel on network 1. Make sure that the power is off. 2. Attach one end of a 16 AWG or larger wire to the ground terminal and connect the other end to the site ground (water pipe). Power Switch (on outside of door) 120 Ω 120 Ω Optional common reference connection if available Connect shield to chassis ground on one panel only Ground (16 AWG or larger) To MD VDC power supply (not polarity sensitive) Figure 5: Chassis Ground and Power LT-6105 rev 1.1 Page 5 of 6
6 11 12 MOUNTING THE MD VDC, 156 W POWER SUPPLY Overall dimensions including door: height: 7 23/32 (196 mm) width: 9 53/64 (250 mm) depth: 2 37/64 (66 mm) Knockout dimensions: 1 1/8 (29 mm) and 7/8 (22 mm) CONNECTING THE POWER 1. Connect the MD-990 load power supply wires to the Touch Screen terminal screws as shown in Figure Connect the building power supply wires to the MD- 990 line terminal screws as shown in Figure Connect the other end of the building power supply wires the line voltage terminals. 4. Turn the power on. 7 3/4 (197 mm) Screws To building power { To Touch Screen { 7 1/5 (191 mm) Figure 7: Power Supply Enclosure 9 1/5 (241 mm) 3 (76 mm) Figure 6: Power Supply Enclosure Dimensions To surface mount the power supply enclosure: 1. Find a suitable location for the power supply enclosure, such as over a wall stud. 2. Using the power supply enclosure as a template, mark the back mounting hole locations as indicated in Figure 7. Ensure that at least one side is over a wall stud. 3. Remove the power supply enclosure and place the top two screws halfway into the marked hole locations and wall stud. 4. Place the power supply enclosure onto the two screws. 5. Screw the other two screws into the remaining holes. 6. Tighten all four screws into place. The enclosure can also be mounted directly onto the drywall using anchors. Figure 8: Terminal block wiring LT-6105 rev 1.1 Page 6 of 6
Package Contents. Mounting Hardware
Securitron Magnalock Corp. www.securitron.com Tel 800.624.5625 techsupport@securitron.com M680BDCX MAGNALOCK SERIES Installation Instructions Table of Contents Specifications 2 Configuring Options 3 Installation
More informationTRAC-Station BT Installation Instructions
TRAC-Station BT Installation Instructions P/N 10103024P1 November 2011 2011 UTC Fire & Security. All rights reserved. Introduction This is the Supra TRAC-Station BT Installation Instructions. Read these
More informationACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS
II 1400-8 Features: ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS Filtered/Regulated 24 Volts DC Up to Full 2 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short Circuit
More informationRequirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING
CAUTION 80-957-00-00 (08-0) Series 570 Door Openings 85 to 0 or to 80 Adjustable Arm and Slide Track Application Maximum Hinge Side Frame Reveal to /8 (mm) Hinge (Pull) Side of Door Installation 5700 LEO
More informationAura CM-55i Flush Mount Illuminated Enclosure Installation Instructions
Aura CM-55i Flush Mount Illuminated Enclosure Installation Instructions Section General Description Camden Aura, Model CM-55i provide the Industry s st Changing State illuminated switch enclosures. They
More informationM670/M680BD MAGNALOCK SERIES Installation Instructions
Securitron www.securitron.com Tel 800.624.5625 techsupport@securitron.com M670/M680BD MAGNALOCK SERIES Installation Instructions Page 1 Rev. D, 12/14 Table of Contents Package Contents... 3 Mounting Hardware...
More information5000 SERIES POWER SUPPLY/CHARGERS INSTALLATION GUIDE
5000 SERIES POWER SUPPLY/CHARGERS INSTALLATION GUIDE MODEL# 505 ( AMP @ VDC OR 4VDC) MODEL# 5500 ( AMP @ VDC OR AMPS @ 4VDC) MODEL# 5600- (0 AMPS @ VDC) MODEL# 5600-4 (5 AMPS @ 4VDC) IMPORTANT SAFETY INSTRUCTIONS
More informationObserve all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.
Introduction OPERATING INSTRUCTIONS: MCD REMOTE OPERATOR Order Codes: 175G94 (for MCD 2) 175G361 + 175G9 (for MCD 5) 175G361 (for MCD 3) 1. Introduction 1.1. Important User Information Observe all necessary
More informationARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI
II 1400-6 ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI ACSI 1426-04-AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1092, REV. C INSTALLATION For C-UL Listed applications,
More informationInstallation Instructions for Series 3100V Low Level Indicator
Instruction Sheet P/N Installation Instructions for Series 3100V Low Level Indicator WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document
More informationRequirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING
CAUTION 80-957-00-00 (08-0) Series 570 Openings 85 to 0 or to 70 Double Lever Arm Application for Frame Reveals (76) to 7 (78mm)* Stop (Push) Side of Installation 5700 LEO Operator Installation Instructions
More informationACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS
II 1400-10 ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS Features: Up to 1.95 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short Circuit Protection Standby Battery
More informationGE Sensing & Inspection Technologies
GE Sensing & Inspection Technologies Modus Model RPM-1 Room Pressure Monitor Installation and Setup Guide 1. GENERAL The RPM-1 monitors either positive or negative room pressures (see the Datasheet for
More informationASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY
00 Series Power Operator Installation and Instruction ASSA Manual ABLOY Item No. Description Motor (00M) Cover (00COV) Control Inverter (00IN) Power Supply VDC (00PS) Track Assembly (0-) / Replacement
More informationSECURITY DOOR CONTROLS
CR4 FOUR STATION CONTROL MODULE The CR4 module operates on 12V or 24V DC and provides control of four (4) stations. Each CR4 station accepts a Dry () trigger input and provides one (1) Fused 2 Amp SPDT
More informationDoor Locking & Exit Hardware
100-00061: Bracket - Maglock Angle for M38 Maglock 100-00098: Exit Accessory - Glass Bar Mount Kit - Includes Adhesive, Mounting Brackets & Cover Plates 100-00191: Handicap Device Handicap Logo Exit Button
More informationPlacing Security In YOUR Hands
" Placing Security In YOUR Hands IVG- 400 INSTALL ATION INSTRUCTIOS Corporate Offices USA: 11 Hartom St, Jerusalem 91450, Israel PO 434, Milford, NJ 08848, USA Tel: + 972-2-535-0000, Fax: + 972-2-586-8683
More informationSEN and SEN Outdoor Air Temperature Sensors
FANs 216, 1628.3 Product/Technical Bulletin SEN-500-2, SEN-500-3 Issue Date 0996 SEN-500-2 and SEN-500-3 Outdoor Air Temperature Sensors The SEN-500-2 and SEN-500-3 Outdoor Air Temperature Sensors offer
More informationTS1 SMARTBOB REMOTE UNIT. INSTALLATION and OPERATING INSTRUCTIONS PLEASE READ CAREFULLY
TS1 SMARTBOB REMOTE UNIT INSTALLATION and OPERATING INSTRUCTIONS PLEASE READ CAREFULLY Division of Garner Industries 7201 No. 98th Street P.O. Box 29709 Lincoln, NE 68507 Lincoln, NE 68529 (402) 434-9102
More informationPower Supplies DORMA PS
Power Supplies DORMA PS DORMA PS Power Supplies Main System On/Off or Fire Panel Relay - The power supply output voltage can be controlled by the main system on/off control relay which accepts a closed
More information2904 Power Supply Installation Instructions I-EA00041
FEATURES Controls an opening with electrified locking device and automatic door operator Separate inputs for activation switch on entry and exit sides of opening Separate 24 VDC outputs for fail safe and
More informationBAPI-Stat Quantum Temperature Sensor with Display and Slider Setpoint
Product Identification and Overview The BAPI-Stat Quantum style room temperature sensor features a large format LCD and slider setpoint adjustment. Additional options include button override and communication
More informationASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY
0 Series Power Operator Installation and Instruction ASSA Manual ABLOY Item No. Description Motor (00M) Cover (00COV) Control Inverter (00IN) Power Supply VDC (00PS) / Replacement Motor Key (00KEY) Rod
More informationINSTALLATION MANUAL. Melink Corporation (513) Revision
INSTALLATION MANUAL Revision 130711 Table of Contents Step Installation Contractor Page 1 Install System Controller Electrical 4 2 Install Variable Frequency Drive Electrical 6 3 Install Touchpad Mechanical
More informationWIRELESS WALL ADJUSTER INSTALLATION, OPERATION AND MAINTENANCE
FORM 040.202 REV 106 WIRELESS WALL ADJUSTER INSTALLATION, OPERATION AND MAINTENANCE Models: ADJ-W Wireless Wall Adjuster Compatible with all Type HC, CW and C Therma-Fuser Diffusers CONTENTS ORDERING...
More informationUSERS MANUAL MCD REMOTE OPERATOR
USERS MANUAL MCD REMOTE OPERATOR Order Code: 175G9004, 175G3061 Contents Contents Introduction...2 Important User Information...2 General Description...2 Symbols Used in this Manual...2 Installation...3
More informationACSI MODEL POWER SUPPLY INSTALLATION INSTRUCTIONS
II 1400-9 ACSI MODEL 1400-6100 POWER SUPPLY INSTALLATION INSTRUCTIONS Features: Used exclusively with the ACSI Series 6100 Communicating Bath Door (Common Bath) System Two separate and identical rows of
More informationOwner s Manual. Model 9300 Vehicular Slide Gate Operator
Owner s Manual Model 9300 Vehicular Slide Gate Operator DoorKing, Inc. 120 Glasgow Avenue Inglewood, California 90301 U.S.A. Phone: 310-645-0023 Fax: 310-641-1586 www.doorking.com P/N 9300-065 Rev C 6/03
More informationblocks Interconnection fuses &
22mm DIAMETER CONTROL SWITCHES Flush Push Buttons CCTTR p17 On/Off Push Button CCTTR0 p17 Arrow Buttons CCTTRA p17 Start/Stop Push Button Start/Stop CCTTRS p18 On/Off CCTTRO p18 40mm E-Stop Key Release
More informationBAPI-Stat 4 Room Humidity Sensor (BA/ B4 -H200 Series)
Overview The BAPI-Stat 4 Style room unit is available as a humidity only sensor or as a combination temperature and humidity sensor with optional LCD display, temperature setpoint adjustment and occupant
More informationBAPI-Stat Quantum Temperature Sensor with Display, Button Setpoint, Fan or System Mode Control
Product Identification and Overview The BAPI-Stat Quantum style room temperature sensor features a large format LCD and pushbutton setpoint adjustment. Additional options include pushbutton override, fan
More informationFM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017
FM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017 Maxi-Tronic, Inc. 417 Wards Corner Road Loveland, OH 45140 513.398.2500 800.659.8250 FAX: 513.398.2536 info@maxitronic.com
More informationDycon D2430 EN54-4 Fire Alarm Power Supply Series
Dycon D2430 EN54-4 Fire Alarm Power Supply Series Technical Description Installation and Operating Manual Construction Product Regulation 0359-CPR-00434 Page 1 of 14 Contents 1. General... 3 1.1 Product
More information5600 Series Power Operator Installation and Instruction Manual
5600 Series Power Operator Installation and Instruction Manual 80-956-000-00 (08-) 5 ASSA ABLOY 6 Item No. Description Motor (5600M) Cover (5600COV) Control Inverter (5600IN) Power Supply VDC (5600PS)
More informationSMP3CTX Series Power Supply/Charger
SMP3CTX Series Power Supply/Charger Installation Guide Models Include: SMP3CTX SMP3PMCTX SMP3PMCTXX - Single Output. SMP3PMP4 - Four (4) Fuse Protected Outputs. SMP3PMP8 - Eight (8) Fuse Protected Outputs.
More information5700 Series Power Operator Hinge (Pull) Side Mount Installation and Instruction ASSA Manual ABLOY
5700 Series Power Operator Hinge (Pull) Side Mount Installation and Instruction ASSA Manual ABLOY 80-957-000-00 (06-5) Patents 5,88,97; 7,6,096; 7,8, 6 5 0 8 7 9 Item No. Description Back plate Door Closer
More informationInstallation. Part A, Section 3. This section covers the following unit configurations: 3400V 3500V Voltage 1, 2, 3 Pump Piston (E, F, G)
Part A, Section 3 Model This section covers the following unit configurations: 3100V 3400V 3500V Voltage 1, 2, 3 Pump Piston (E, F, G) Manifold Control 4-Port (A) 6-Port (B) Vista Temperature (TC) A 3-0
More informationElectrical Options Booklet. Table of Contents
*24228413* 24228413 Electrical Options Booklet Table of Contents EL Wiring... EL Troubleshooting... SD/EL 98/99 Cylinder Dogging... SS Wiring... 330, 350, RX-330 and RX-350 Push Bar Trim Mechanical Installation...
More informationonlinecomponents.com Compact Coded Magnetic Safety Interlock Switch and Control Unit
C Conforms to EN94-1, EN1088, EN60204-1 UL and C-UL listed Description R US Compact Coded Magnetic Safety Interlock Switch and Control Unit Dual channel, fully monitored system; meets Category 3 when single
More information24HR 30A SPST TM SW. Features. Long Description
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-794 Fax: 936-560-4685 ET05C 24HR 30A SPST TM SW Intermatic Inc. Catalog Number Manufacturer Description Weight per unit Product Category ET05C
More informationIMC SOLAR EAGLE 2 DIFFERENTIAL TEMPERATURE CONTROLLERS
DIFFERENTIAL TEMPERATURE CONTROLLERS MAIN FEATURES - Microprocessor programed specifically for optimal performance of WARM AIR systems - Large easy-to-read 40 character (x0) backlit LCD display showing
More informationSentinel Field Satellite Controller
WARNING HIGH VOLTAGE 115V M AP Sentinel Field Satellite Controller Installation Instructions Important: For your protection and the safety of the product user, please comply with all Caution and Warning
More informationMAPNET II Transceiver Installation Instructions
MAPNET II Transceiver Installation Instructions Introduction This publication describes the installation procedure for the following versions of the MAPNET II Transceiver card. 4120/4100-0110 MAPNET II
More informationT57 SERIES LOW ENERGY OPERATOR INTRODUCTION FEATURES BENEFITS PATENTS TABLE OF CONTENTS
INTRODUCTION A reliable ADA solution for moderate traffic applications, the T57 Low Energy Operator comprises Norton s heavy-duty 1601 door closer. The use of a hydraulic closer ensures quiet and consistently
More informationS450H 24V Hydraulic Swing Gate Operator
S450H 24V Hydraulic Swing Gate Operator UL325 - UL991 FAAC International Inc. Headquarter & East Coast Operations 3160 Murrell Road Rockledge, FL 32955 Tel. 800 221 8278 www.faacusa.com FAAC International
More information8. Do not install this product on the exterior of buildings. 9. Do not use as a doorstop. This will void warranty. Installation Instructions
INSTALLATION 8310-IQ/8320-IQ IntelliMag Electromagnetic Locks Pre-Installation Instructions 1. This product must be installed according to all applicable building and life safety codes. 2. Due to the variety
More informationMove to modern enclosed disconnect switch technology. Enclosed disconnect switches eot Manual motor controllers
Move to modern enclosed disconnect switch technology Enclosed disconnect switches eot Manual motor controllers The next generation of enclosed disconnect switches... Cutting edge design and technology
More informationINSTALLATION GUIDE. InBio Pro Series Access Control Panels. Date: Dec., 2015 Version: 1.1
INSTALLATION GUIDE InBio Pro Series Access Control Panels Date: Dec., 2015 Version: 1.1 2 3 What s in the Box CONTENT 2 Screws & Anchors 2 Screwdriver 4 Diode Contents What s in the Box...2 Optional accessories...4
More informationDycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD
Dycon D1532SM EN50131/PD6662 Grade 3, 12V 2A Power Supply Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD Tel: +44 (0)1443 471 900 Unit A Cwm Cynon Business Park Mountain
More information* * E996L Series. E996L for Rim/Vertical. E996L for Mortise CAUTION
*921297-00* 921297-00 Electric Locking Trim E996L Series Installation Instructions CAUTION Product is shipped in Fail Safe (FS) configuration. Fail Safe configuration is required by code in some applications
More informationInstallation. Part A, Section 3. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, or G)
Part A, Section 3 Model This section covers the following unit configurations. Voltage 4 3100V 3400V 3500V Pump Piston (E, F, or G) Manifold Control 4-Port (A) 6-Port (B) Vista Temperature (TC) A 3-0 A
More informationWall-Mount Server Rack with Built-in Shelf - Solid Steel - 8U
Wall-Mount Server Rack with Built-in Shelf - Solid Steel - 8U Product ID: WALLSHELF8U This wall-mount rack provides 8U of space for mounting your servers or A/V equipment to a wall. The rack also has a
More informationFES112 HIGH SECURITY ELECTRIC CUSTODIAL STRIKE INSTALLATION MANUAL
FES112 HIGH SECURITY ELECTRIC CUSTODIAL STRIKE INSTALLATION MANUAL 1 P age 1. INTRODUCTION The FES112 High Security Electric Custodial Strike was purposely designed for heavy duty high security applications
More informationINQUIRY: HYROBOTICS CORP SAM LEE ( ) 5988 MID RIVER MALL DR. ST.CHARLES MO TEL : FAX :
INQUIRY: HYROBOTICS CORP SAM LEE ( Email : hanrobotic@msn.com ) 5988 MID RIVER MALL DR. ST.CHARLES MO 63304 TEL : 1-636-578-6059 FAX : 1-866-232-5594 1. Picker Body Installation 1-1. Picker Assembly. (Step
More informationmodel ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION
MODEL: PS600 HZ: 60 A model ps600 installation and service manual for federal model ps600 FEDERAL SIGNAL CORPORATION POWER SUPPLY VOLTS: SERIES: 120VAC FEDERAL SIGNAL CORPORATION UNIVERSITY PARK, IL. U.S.A.
More informationASSA ABLOY MPI (Infinite Hold Open Range) Support Unit Models. Multi-Point Electromechanical Overhead Concealed Closer Holder Releasing Device
Overhead Concealed Closer Holder Releasing Device with Rigid Slide Arm For wood or metal doors 1-3/4 to 2-1/4" (45-57mm) thick Hung in a hollow metal frame Standard butt hinges Typical Installation One
More informationAccuPower AQU128B Installation Instructions
Tel 1.800.MAGLOCK info@securitron.com 1.800.624.5625 www.securitron.com AccuPower AQU128B Installation Instructions Recommended Tools & Additional Materials #2 Phillips Screw Driver Wire connectors Lead
More informationD-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators
Installation D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators IMPORTANT: The D- Series actuators are intended to control equipment under normal operating conditions. Where failure
More informationV1504 Vertical Platform Lift OWNER S MANUAL
V1504 Vertical Platform Lift OWNER S MANUAL (To Be Retained by Owner After Installation by Authorized Savaria Dealer) Part No. 000692 30-m06-2017 2 IMPORTANT Ensure that only an authorized Savaria Dealer
More informationSafety-door Switch D4NS. Model Number Structure. Model Number Legend
Safety-door Switch D4NS Multi-contact, Labor-saving, Environmentfriendly, Next-generation Safety-door Switch Lineup includes MBB models and three contact models with 2NC/1NC and 3NC contact forms in addition
More informationMULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers
IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when
More informationINSTALLATION INSTRUCTIONS FOR Owner's Copy FILTERED AND REGULATED POWER SUPPLY VOLTS DC INPUT: Hz.
103158 March 9, 2011 FOR INDOOR USE ONLY Detex Corporation, 302 Detex Drive, New Braunfels, Texas 78130-3045 (830)629-2900 / 1-800-729-3839 / Fax (830)620-6711 E-MAIL: detex@detex.com INTERNET: www.detex.com
More informationAC Powered. AC Powered. Model Installation/Owner s Manual. UL 325 Compliant. AC Powered Vehicular Swing Gate Operator
Installation/Owner s Manual Model 652-080 AC Powered Vehicular Swing Gate Operator Use this manual for circuit board 100-010 Revision AA or higher. EXTERNAL ENTRAPMENT PROTECTI MUST be installed or the
More informationSED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options
SED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options Product Description The SED2 Conventional Bypass (C-Bypass) Options are companion packages for the family of SED2 Variable Frequency
More informationVA-7450 Series. Electric Valve Actuators
34-636- 771, Rev. D Installation Instructions VA-7450 Series Issue Date 0216 VA-7450 Series Electric Valve Actuators Applications VA-7450 Series Electric Valve Actuators provide on/off, floating, or proportional
More informationElectric strikes. An electric strike is an electromechanical device installed on the door frame allowing an electrical opening. Installation modes
Electric strikes An electric strike is an electromechanical device installed on the door frame allowing an electrical opening. Installation modes Flush mounted electric Rim electric strike installation
More informationAC Powered. AC Powered. Model Installation/Owner s Manual. AC Powered Vehicular Swing Gate Operator. UL 325 August 2018 Standard
Installation/Owner s Manual Model 6524-380 AC Powered Vehicular Swing Gate Operator Use this manual for circuit board 4100-018 Revision A or higher. Entrapment Protection must be provided for the gate
More information24V 3A EN54 Ancillary Power Supply
24V 3A EN54 Ancillary Power Supply Normal supply - green light on Fault condition - call Engineer Control relay - activated 3A Power Supply C-TEC Manufactured in England by C-Tec EN 54-4 : 1997 INSTALLATION
More informationIMC SOLAR EAGLE 2 DIFFERENTIAL TEMPERATURE CONTROLLERS
DIFFERENTIAL TEMPERATURE CONTROLLERS MAIN FEATURES - PV POWERED from 0 V to VDC with smart power management at very low PV power levels, A must, for soft FAN start & smooth controller operation - Microprocessor
More informationTechnical specification
15. Nov. 2010 Page 1 (5) Metso Rotating Sensor part - Rotating shear force based transmitter for pulp consistency measurement in pulp and paper industry. - Sensing element selection based on pulp type
More informationLP-2500/2600. Installation and Setup Guide. Lighting Control Panels. Revision 3.1 July 1999
/2600 Lighting Control Panels Installation and Setup Guide Revision 3. July 999 Phone:770-429-3043 http://www.triateklighting.com sales@triateklighting.com Installation Guide /2600 Lighting Panels Table
More informationPatient Care Facility
ISIMET Patient Care Facility DLA Controller Individual Room Configuration Style 1 W/ Ver 4.41 pcb & Pulse Relay pcb Installation, Operations, Start-up and Maintenance Instructions Meets all Standards for
More information- 8 amp (200VA) - 8 amp (200VA) - Sixteen (16) Fuse Protected Outputs. - Sixteen (16) PTC Protected Outputs.
ALTV2416 Series CCTV ower Supplies Installation Guide Models Include: ALTV2416 ALTV2416CB - @ 8 amp (200VA) - @ 8 amp (200VA) or @ 7 amp. or @ 7 amp. - Sixteen (16) Fuse rotected Outputs. - Sixteen (16)
More informationDC CCTV Power Supplies Installation Guide
DC CCTV Power Supplies Installation Guide Models Include: Sav4D - 12VDC @ 5 amp - Four (4) Class 2 Rated PTC Protected Power-Limited Outputs. Sav9D - 12VDC @ 5 amp - Nine (9) Class 2 Rated PTC Protected
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-G V
Description Single and two pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast magnetic only or hydraulically delayed switching characteristics
More informationDrug Testing Labs. Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions
ISIMET Drug Testing Labs DLA Controller Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions Meets all Standards for Canadian Industrial Control
More informationA419 Series Electronic Temperature Controls with NEMA 1 or NEMA 4X Watertight Enclosures
Installation Instructions Issue Date April 8, 2008 A419 Series Electronic Temperature Controls with NEMA 1 or NEMA 4X Watertight Enclosures Application IMPORTANT: The A419 Series Electronic Temperature
More informationInlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00
Inlet Controller TC5-ITA USER'S MANUAL M 890-00047 rev. 02 K 895-00458 rev. 00 TABLE OF CONTENTS PRECAUTIONS... 3 FEATURES... 4 LOCATION OF THE CONTROLS... 5 Status Leds...5 Internal Switches...6 INSTALLATION
More informationPre-Installation Instructions
Pre-Installation Instructions 1. This product must be installed according to all applicable building and life safety codes. All installations must be approved by the Authority Having Jurisdiction (AHJ).
More informationCombined Ventilation Controller RVWS-T-224HA
Combined Ventilation Controller RVWS-T-224HA 8-stage Control for Power/Natural Applications 2 variable speed stages, 2 curtain winch stages, 2 fixed speed ventilation stages, 1 thermo/mister cycle stage
More informationSeries 1000 Room Temperature Sensors, 1K Ω Platinum (375α) RTD (MBC/RBC/MEC/UC)
Document No. 540-743 Series 1000 Room Temperature Sensors, 1K Ω Platinum (375α) RTD (MBC/RBC/MEC/UC) Product Description These sensors work with the Modular Building Controller (MBC), Remote Building Controller
More informationTOPAZ 24 DIMMER RACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT A)
TOPAZ 24 DIMMER RACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT-29132-1A) Contractor: Please read these instructions before starting installation. After installation, please forward this guide to the
More informationJtec 489 UL489 Branch Circuit Breaker
Jtec 489 UL489 Branch Circuit Breaker 10kA Miniature Circuit Breaker R The Jtec 489 range is UL 489 listed (File E255530). Available in trip curves Z (v. quick), B (quick), C (medium), K (motor) and D
More informationAdams rite. Exit Devices & parts exit devices series exit device parts
Adams rite Exit Devices & parts exit devices 8099 8211 8099 Active Dummy Bar with Switch Can be wired normally open or normally closed to operate maglock, alarm, etc No latching mechanism 8211 Surface
More informationOwner s Manual. Model 9310 Vehicular Slide Gate Operator
Owner s Manual Model 930 Vehicular Slide Gate Operator DoorKing, Inc. 20 Glasgow Avenue Inglewood, California 9030 U.S.A. Phone: 30-65-0023 Fax: 30-6-586 www.doorking.com P/N 930-065 Rev D 5/05 Copyright
More informationBAPI-Com, Two Wire Multifunction Sensor BA/BS4SCOM Temperature/Humidity Sensor Installation and Operating Instructions
Product Identification Fig 1. BAPI-Com Communication Output Module Fig 2. BAPI-Com Room Sensor, BA/BS4SCOM Operations Overview The BAPI-Com sensor is designed to be used in retrofit applications on just
More informationInstallation. Part A, Section 3. This section covers the following unit configurations. Voltage 1, 2, 3. Vista Standard (V) A3EN-04-[3V-A-AAXV]-11
Part A, Section 3 This section covers the following unit configurations. Model All Voltage 1, 2, 3 Pump All Manifold All Control Vista Standard (V) A 3-0 A 3-1 Section A 3 WARNING: Allow only qualified
More informationFIRE DOOR OPERATOR WARNING INSTALLATION LOGIC BOARD REPLACEMENT KIT K , K A-400 & K B-400 APPLICATION REMOVE AC AND DC POWER
APPLICATION Replacement of logic board for Models FDO and FDC operators with Rev. 400 wiring. FIRE DOOR OPERATOR LOGIC BOARD REPLACEMENT KIT K79-3493-400, K79-3493A-400 & K79-3493B-400 WARNING To prevent
More informationInstallation and Operation Instructions DLP Series
Installation and Operation Instructions DLP Series PRECAUTIONS Figure 1: DLP Dimensions and Hardware REMOVE POWER BEFORE WIRING. NEVER CONNECT OR DISCONNECT WIRING WITH THE POWER APPLIED. DO NOT ALLOW
More informationZodiac Max INSTALLATION MANUAL
Zodiac Max INSTALLATION MANUAL October 2015 Table of Contents Introduction... 4 Specifications... 5 Overview... 6 Reader Address Settings... 7 Wiring to a Wiegand Controller... 8 CLAUSB... 9 CLAUSB2...
More information!!!! ! Lock housing dimensions: 230mm L x 44mm W x 44mm D! Receptacle housing dimensions: 120m L x 44mm W x 44mm D. ! Surface mount housing for LK120
ELECTROMAGNETIC LK120 Bolt Action Lock SP (Fail Safe) Fail-Safe: Strike Plate: Bolt Stainless Steel: 200(L) x 32(W) x 40(D) mm 90(L) x 26(W) x 2(D) mm 15.5mm Diameter, 17mm Throw 12V Operation Operation
More informationFan Coil Thermostat. Specification & Installation instructions TFC54F3X1. Technical Data
Fan Coil Thermostat Feature: Selectable analog & digital output Selectable fan speed contact Selectable Fahrenheit or Celsius scale Manual Night Set Back override (programmable) Multi level lockable access
More informationINSTALLATION MANUAL FOR
MOUNTING LOCATION Reader RD- FOR RF CONTROLLER VIZIT-KTM60 R, EXIT 00M BUTTON This manual is intended as an addition to operating instructions on your access control system (ACS) units to guide through
More informationOwner s Manual. Model 9100 Vehicular Slide Gate Operator
Owner s Manual Model 9100 Vehicular Slide Gate Operator DoorKing, Inc. 120 Glasgow Avenue Inglewood, California 90301 U.S.A. Phone: 310-645-0023 Fax: 310-641-1586 www.doorking.com P/N 9100-065 REV C, 1/04
More information8. Do not install this product on the exterior of buildings. 9. Do not use as a doorstop. This will void warranty. Installation Instructions
INSTALLATI DE8310 Delayed Egress Electromagnetic Locks Pre-Installation Instructions 1. This product must be installed according to all applicable building and life safety codes. All installations must
More informationSeries BFM Bulk Flow Monitor 1A FUSE RED LED RELAY. Part Number BFM-1 BFM-2 BFM-3 BFS-1
Series Bulk Flow Monitor Specifications - Installation and Operating Instructions Bulletin FL-1-4x 3/4 CONDUIT KNOCKOUTS BFS 1A FUSE RED LED RELAY 5-9/64 [130.45] TRANSFORMER 3[76.20] GREEN LED 7 [177.80]
More informationAdjustable Torque Controls
MCS0 Adjustable Torque Control The MCS0 is an enclosed control complete with a cover and mounting provisions. A brake and clutch may be operated separately with this control or up to four units, two at
More informationRETRO SOLUTIONS PRODUCT CATALOG
RETRO SOLUTIONS PRODUCT CATALOG 4634 S. Presa Street, San Antonio, TX 78223 Phone 210-533-1231 Fax 210-533-2211 www.southernfolger.com See who we are. See all we do. T A B L E O F C O N T E N T S RETRO
More informationNMQB24-MFT, NMQX24-MFT Quick Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology
NMQB-MFT, NMQX-MFT Quick Proportional Control, Non-Spring Return, Direct Coupled, V, Multi-Function Technology Application For proportional modulation of dampers in HVAC systems. Actuator sizing should
More informationSHEAR ALIGNING MAGNALOCK MODEL SAM2-24 INSTALLATION AND OPERATING INSTRUCTIONS
Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.6.5625 techsupport@securitron.com in door opening solutions SHEAR ALIGNING MAGNALOCK MODEL SAM2- INSTALLATION AND OPERATING
More information