FIRE DOOR OPERATOR WARNING INSTALLATION LOGIC BOARD REPLACEMENT KIT K , K A-400 & K B-400 APPLICATION REMOVE AC AND DC POWER

Size: px
Start display at page:

Download "FIRE DOOR OPERATOR WARNING INSTALLATION LOGIC BOARD REPLACEMENT KIT K , K A-400 & K B-400 APPLICATION REMOVE AC AND DC POWER"

Transcription

1 APPLICATION Replacement of logic board for Models FDO and FDC operators with Rev. 400 wiring. FIRE DOOR OPERATOR LOGIC BOARD REPLACEMENT KIT K , K A-400 & K B-400 WARNING To prevent possible SERIOUS INJURY or DEATH from electrocution, disconnect electric power to operator BEFORE installing. ALL electrical connections MUST be made by a qualified individual. INSTALLATION REMOVE AC AND DC POWER. Disconnect AC power to the operator. 2. Open operator cover. 3. Remove DC power by disconnecting the battery connection. REMOVE EXISTING BOARD. Match replacement logic board dip switch settings to the current logic board. Refer to page 7, if needed. 2. Remove all the ends of the wires connected to the existing board and neatly lay them over the side of the electrical box. Leave jumper wires located on the board connected until new logic board wiring. 3. Remove the nylon nuts (7) holding the logic board to the electrical box and hold for reassembly of new board. 4. Remove the screw holding the heat sink to the electrical box and hold for reassembly of new board. 5. Remove logic board from the box, leaving the existing standoffs in place. INSTALL NEW BOARD. Install the new logic board in the electrical box using the old standoffs. Be sure to install in the same configuration as it was removed. 2. Secure logic board in place with the nylon nuts (7) removed in step Secure the heat sink to the electrical box with the screw removed in step 4. Three Phase DC Operators Follow wiring directions on page 8. For additional help refer to the wiring diagram on page 9. Single Phase Operators, FDC Follow wiring directions on page 0. For additional help refer to the wiring diagram on page. Three Phase Operators, FDC Follow wiring directions on page 2. For additional help refer to the wiring diagram on page 3. PROGRAM SETTINGS Follow instructions on page 4 for FDO optional control settings. Follow instructions on page 5 for FDC optional control settings and installer control settings. CONTROL CONNECTIONS Follow instructions on page 20 for FDO, FDC and FDCL optional control connections. LOGIC BOARD WIRING Single Phase AC Operators Follow wiring directions on page 2. For additional help refer to the wiring diagram on page 3. Single Phase DC Operators Follow wiring directions on page 4. For additional help refer to the wiring diagram on page 5. Three Phase AC Operators Follow wiring directions on page 6. For additional help refer to the wiring diagram on page 7.

2 NOTE: For additional help with wiring refer to the wiring diagram on next page. EXISTING WIRES SINGLE PHASE AC WIRING JUMPER WIRES NOTE: Remove jumpers from original board and install them on new logic board as follows.. Connect the black wire from pin J7 to #23 on the terminal block. 2. Connect the yellow wire from pin 3 to pin Connect the blue wire from pin to pin Connect the orange wire from pin 4 to pin Connect the brown wire that runs from #6 to #20 on the terminal block. 6. Connect the original blue wire from pin J2 to #8 on the terminal block. 7. Connect the black wire from pin J30 to #24 on the terminal block. TRANSFORMER. Connect the black wire that runs from the primary on the transformer to pin Connect the white wire that runs from the primary on the transformer to pin Connect one of the brown wire that runs from the secondary on the transformer to pin J9. 4. Connect one of the brown wire that runs from the secondary on the transformer to pin J8. LIMIT SWITCHES Connect the original limit harness to the 4 pin terminal on the board marked J3 limit switch. MOTOR. Connect the original grey wire from the motor to pin J6. 2. Connect the blue wire from the motor to pin Connect the purple wire from the motor to pin J7. 4. Connect the yellow wire from the motor to pin J5. OVERLOAD. Connect one of the black wires from the overload to pin Connect one of the black wires from the overload to pin 6. NOTE: For pushbuttons, sensing devices, power wiring and other additional options refer to wiring diagram on next page. BRAKE. Connect the black wire from the brake to pin J7. 2. Connect the red wire from the brake to pin J6. 2

3 SINGLE PHASE WIRING DIAGRAM (FDO50A24V) NOTES: See owner s manual for dip switch functions and programming procedures. To reverse motor direction: Reverse purple and gray motor wires. For B2 wiring remove one end of jumper from -3 and connect to

4 NOTE: For additional help with wiring refer to the wiring diagram on next page. EXISTING WIRES SINGLE PHASE DC WIRING JUMPER WIRES NOTE: Remove jumpers from original board and install them on new logic board as follows.. Connect the original blue wire from pin J8 to pin J2. 2. Connect the original yellow wire from pin 3 to pin Connect the original blue wire from pin to pin Connect the original orange wire from pin 4 to pin Connect the original brown wire that runs from #6 to #20 on the terminal block. TRANSFORMER. Connect the original black wire that runs from the primary on the transformer to pin Connect the original white wire that runs from the primary on the transformer to pin Connect one of the original brown wire that runs from the secondary on the transformer to pin J9. 4. Connect one of the original brown wire that runs from the secondary on the transformer to pin J8. BRAKE. Connect the original black wire that runs from the brake to pin J7. 2. Connect the original red wires that runs from the brake to pin J6. LIMIT SWITCHES Connect the original limit harness to the 4 pin terminal on the board marked J3 limit switch. RPM BOARD Connect the original RPM harness to the 4 pin terminal on the board marked J4 RPM board. MOTOR. Connect the original grey wire from the motor to pin J6. 2. Connect the original blue wire from the motor to pin Connect the original purple wire from the motor to pin J7. 4. Connect the original yellow wire from the motor to pin J5. OVERLOAD. Connect one of the original black wires from the overload to pin Connect one of the original black wires from the overload to pin 6. BATTERY. Connect the original black wire from the negative battery terminal to pin J4. 2. Connect the original red wire from the positive battery terminal to pin J3. RESISTOR. Connect the original black wire from the resistor to pin J Connect the original red wire from the resistor to pin J9. NOTE: For pushbuttons, sensing devices, power wiring and other additional options refer to wiring diagram on next page. 4

5 SINGLE PHASE WIRING DIAGRAM (FDO50B24V) 935 NOTES: See owner s manual for dip switch functions and programming procedures To reverse motor direction: Reverse purple and gray motor wires. For B2 wiring remove one end of jumper from -3 and connect to -6. 5

6 THREE PHASE AC WIRING NOTE: For additional help with wiring refer to the wiring diagram on next page. EXISTING WIRES JUMPER WIRES NOTE: Remove jumpers from original board and install them on new logic board as follows.. Connect the black wire from pin J7 to #23 on the terminal block. 2. Connect the blue wire from pin 7 to pin Connect the brown wire that runs from #6 to #20 on the terminal block. 4. Connect the brown wire that runs from J2 to #8 on the terminal block. 5. Connect the black wire that runs from J30 to #24 on the terminal block. TRANSFORMER. Connect the black wire that runs from the primary on the transformer to T2 on the overload. 2. Connect the white wire that runs from the primary on the transformer to T on the overload. 3. Connect one of the brown wires that runs from the secondary on the transformer to 96 on the overload. 4. Connect one of the brown wires that runs from the secondary on the transformer to pin J8. LIMIT SWITCHES Connect the limit harness to the 4 pin terminal on the board marked J3 limit switch. MOTOR. Connect the grey wire from the motor to pin J7. 2. Connect the purple wire from the motor to pin J6. 3. Connect the yellow wire from the motor to pin J5. OVERLOAD. Connect the brown wire from 95 on the overload to pin J9. 2. Connect the black wire from T3 on the overload to pin Connect the black wire from T2 on the overload to pin Connect the black wire from T on the overload to pin. 5. Connect the black wire from L on the overload to pin Connect the black wire from L2 on the overload to pin Connect the black wire from L3 on the overload to pin 9. NOTE: For pushbuttons, sensing devices, power wiring and other additional options refer to wiring diagram on next page. BRAKE. Connect the black wire from the brake to pin J7. 2. Connect the red wire from the brake to pin J6. 6

7 THREE PHASE WIRING DIAGRAM (FDO023A34V & FDO043A24C) 936 NOTES: See owner s manual for dip switch functions and programming procedures. To reverse motor direction: Reverse purple and gray motor wires. For B2 wiring remove one end of jumper from -3 and connect to -6. MOTOR CONNECTION MOTOR CONNECTION (BN) (GY) (PU) (BN) (GY) (PU) (BN) (BN) INTERNAL MOTOR CONNECTIONS 7

8 NOTE: For additional help with wiring refer to the wiring diagram on next page. EXISTING WIRES THREE PHASE DC WIRING JUMPER WIRES NOTE: Remove jumpers from original board and install them on new logic board as follows.. Connect the original blue wire from pin J8 to pin J2. 2. Connect the original blue wire from pin 7 to pin Connect the original brown wire that runs from #6 to #20 on the TERMINAL BLOCK. 4. Connect the original brown wire that runs from J2 to #8 on the TERMINAL BLOCK. TRANSFORMER. Connect the original black wire that runs from the primary on the transformer to T2 on the overload. 2. Connect the original white wire that runs from the primary on the transformer to T on the overload. 3. Connect one of the original brown wires that runs from the secondary on the transformer to 96 on the overload. 4. Connect one of the original brown wires that runs from the secondary on the transformer to pin J8. BRAKE. Connect the original black wire that runs from the brake to pin J7. 2. Connect the original red wire that runs from the brake to pin J6. BATTERY. Connect the original black wire from the negative battery terminal to pin J4. 2. Connect the original red wire from the positive battery terminal to pin J3. RESISTOR. Connect the original black wire from the resistor to pin J Connect the original red wire from the resistor to pin J9. LIMIT SWITCHES Connect the original limit harness to the 4 pin terminal on the board marked J3 LIMIT SWITCH. RPM SENSOR a. Connect the original limit harness to the 4 pin terminal on the board marked J4 RPM SENSOR. MOTOR. Connect the original grey wire from the motor to pin J7. 2. Connect the original purple wire from the motor to pin J6. 3. Connect the original yellow wire from the motor to pin J5. OVERLOAD. Connect the original brown wire from 95 on the overload to pin J9. 2. Connect the original black wire from T3 on the overload to pin Connect the original black wire from T2 on the overload to pin Connect the original black wire from T on the overload to pin. 5. Connect the original black wire from L on the overload to pin Connect the original black wire from L2 on the overload to pin 0. Connect the original black wire from L3 on the overload to pin 9. NOTE: For pushbuttons, sensing devices, power wiring and other additional options refer to wiring diagram on next page. 8

9 THREE PHASE WIRING DIAGRAM (FDO023B24V & FDO043B24V 937 NOTES: See owner s manual for dip switch functions and programming procedures To reverse motor direction: Reverse purple and gray motor wires. For B2 Wiring Remove One End of Jumper from -3 and Connect to -6. MOTOR CONNECTION MOTOR CONNECTION (BN) (GY) (PU) (BN) (GY) (PU) (BN) (BN) INTERNAL MOTOR CONNECTIONS 9

10 NOTE: For additional help with wiring refer to the wiring diagram on next page. THREE PHASE WIRING, FDC EXISTING WIRES JUMPER WIRES NOTE: Remove jumpers from original board and install them on new logic board as follows.. Connect the original blue wire from pin J8 to pin J2. 2. Connect the original yellow wire from pin 3 to pin Connect the original blue wire from pin to pin Connect the original orange wire from pin 4 to pin Connect the original brown wire that runs from #6 to #23 on the terminal block. TRANSFORMER. Connect the original black wire that runs from the primary on the transformer to pin Connect the original white wire that runs from the primary on the transformer to pin Connect one of the original brown wire that runs from the secondary on the transformer to pin J9. 4. Connect one of the original brown wire that runs from the secondary on the transformer to pin J8. BRAKE. Connect the original white wire that runs from the brake to pin J7. 2. Connect the original white/black wires that runs from the brake to pin J6. LIMIT SWITCHES Connect the original limit harness to the 4 pin terminal on the board marked J3 LIMIT SWITCH. RPM BOARD Connect the original RPM harness to the 4 pin terminal on the board marked J4 RPM BOARD. MOTOR. Connect the original grey wire from the motor to pin J6. 2. Connect the original blue wire from the motor to pin Connect the original purple wire from the motor to pin J7. 4. Connect the original yellow wire from the motor to pin J5. OVERLOAD. Connect one of the original black wires from the overload to pin Connect one of the original black wires from the overload to pin 6. BATTERY. Connect the original black wire from the negative battery terminal to pin J4. 2. Connect the original red wire from the positive battery terminal to pin J3. RESISTOR. Connect the original black wire from the resistor to pin J Connect the original red wire from the resistor to pin J9. NOTE: For pushbuttons, sensing devices, power wiring and other additional options refer to wiring diagram on next page. 0

11 SINGLE PHASE WIRING DIAGRAM (FDC5024V, FDC50224V, FDC024V, FDC024V) 892 INTERNAL MOTOR CONNECTIONS NOTES: See owner s manual for dip switch functions and programming procedures. To reverse motor direction: Reverse purple and gray motor wires running to J6 and J7 on the board. To reverse limit switch direction: Move yellow and white wires from safety limit switch to spare auxiliary switch (see page 7). Connections shown in dotted boundaries are optional user interface. ** (K7, K8) are normally open dry contacts which are programmed to close on any alarm signal. (K6) is normally open dry contact which is programmed to close when the door is in motion or inhibited during a gravity close. (BL) (SPARE) LIMIT SWITCH SAFETY LIMIT SWITCH CLOSE LIMIT SWITCH OPEN LIMIT SWITCH - + RESISTOR CAPACITOR OUTPUTS ** 2VDC BATTERY POWER DISCONNECT J4 J5 J3 J3 RPM BOARD (GW) J4 S J30 J8 (BL) DC BRAKE COIL - + J7 (WH/BK) J6 J9 J5 4 3 MOTOR (K6) OPTIONAL MOTION STROBE (OR) J6 (GY) (K7) OPTIONAL FIRE SIREN (BL) J7 (PU) (K8) OPTIONAL FIRE STROBE 5 ALARM INPUT#2 (FACTORY JUMPER SUPPLIED) ELECTRONIC FUSE LINK AMP MAX AMP MAX +24 VAC +24 VAC +24 VDC GRD GND TB INTERNAL THERMAL SENSOR FUSE 2AMP J J9 (FACTORY JUMPER) J (WH/BK) IR'S REVERSE EDGE C NO KEY-TEST OPEN CLOSE OVERLOAD J L L2 L3 5V N 5V PH POWER IN ONLY GND ALARM INPUT# (DRY CONTACT ONLY, DO NOT INDUCE VOLTAGE!) (BL) STOP LOW BATTERY INDICATOR TRANSFORMER SECONDARY PRIMARY (SHOWN AS LEFT HAND UNIT) POWER DISCONNECT

12 NOTE: For additional help with wiring refer to the wiring diagram on next page. EXISTING WIRES THREE PHASE WIRING, FDC JUMPER WIRES NOTE: Remove jumpers from original board and install them on new logic board as follows.. Connect the original blue wire from pin J8 to pin J2. 2. Connect the original blue wire from pin 7 to pin Connect the original brown wire that runs from #6 to #23 on the terminal block. 4. Connect the original black wire from pin to pin Connect the original black wire from pin 0 to pin Connect the original black wire from pin 4 to pin 9. TRANSFORMER. Connect the original black wire that runs from the primary on the transformer to T2 on the overload. 2. Connect the original white wire that runs from the primary on the transformer to T on the overload. 3. Connect one of the original brown wires that runs from the secondary on the transformer to 96 on the overload. 4. Connect one of the original brown wires that runs from the secondary on the transformer to pin J8. BRAKE. Connect the original white wire that runs from the brake to pin J7. 2. Connect the original white/black wire that runs from the brake to pin J6. BATTERY. Connect the original black wire from the negative battery terminal to pin J4. 2. Connect the original red wire from the positive battery terminal to pin J3. RESISTOR. Connect the original black wire from the resistor to pin J Connect the original red wire from the resistor to pin J9. LIMIT SWITCHES Connect the original limit harness to the 4 pin terminal on the board marked J3 limit switch. RPM SENSOR Connect the original limit harness to the 4 pin terminal on the board marked J4 RPM sensor. MOTOR. Connect the original grey wire from the motor to pin J7. 2. Connect the original purple wire from the motor to pin J6. 3. Connect the original yellow wire from the motor to pin J5. OVERLOAD. Connect the original brown wire from 95 on the overload to pin J9. 2. Connect the original black wire from T3 on the overload to pin Connect the original black wire from T2 on the overload to pin Connect the original black wire from T on the overload to pin. 5. Connect the original black wire from L on the overload to pin Connect the original black wire from L2 on the overload to pin Connect the original black wire from L3 on the overload to pin 9. NOTE: For pushbuttons, sensing devices, power wiring and other additional options refer to wiring diagram on next page. 2

13 THREE PHASE WIRING DIAGRAM (FDC502324V, FDC504324V, FDC02324V, FDC04324V) 893 * * POWER DISCONNECT (BL) (SPARE) LIMIT SWITCH SAFETY LIMIT SWITCH CLOSE LIMIT SWITCH OPEN LIMIT SWITCH RPM BOARD (GW) - + RESISTOR CAPACITOR DC BRAKE COIL - + (WH/BK) INTERNAL MOTOR CONNECTIONS MOTOR MOTOR O/L * SEE NOTE 4 (PU) (GY) OUTPUTS * * 2VDC BATTERY J4 J5 J3 J3 J4 S J30 J8 (BL) J7 J6 J9 J5 4 3 (K6) OPTIONAL MOTION STROBE (K7) OPTIONAL FIRE SIREN (K8) OPTIONAL FIRE STROBE J6 J7 5 ALARM INPUT#2 (FACTORY JUMPER SUPPLIED) ELECTRONIC FUSE LINK GND TB FUSE 2AMP INTERNAL THERMAL SENSOR J J9 (FACTORY JUMPER) J (BL) J L L2 L3 L L2 L3 GND OVERLOAD (HP & ABOVE) L3 T3 L2 T2 L T AMP MAX AMP MAX +24 VAC +24 VAC +24 VDC GRD (WH/BK) IR'S REVERSE EDGE C NO KEY-TEST OPEN CLOSE 230/460 3PH POWER IN ALARM INPUT# (DRY CONTACT ONLY, DO NOT INDUCE VOLTAGE!) STOP POWER DISCONNECT NOTES: See owner s manual for dip switch functions and programming procedures. To reverse motor direction: Reverse purple and gray motor wires running to J6 and J7 on the board. To reverse limit switch direction: Move yellow and white wires from safety limit switch to spare auxiliary switch (see page 7). Connections shown in dotted boundaries are optional user interface. * Internal motor overload on models up to and including 3/4 HP. External overload located in electrical enclosure for HP models. ** (K7, K8) are normally open dry contacts which are programmed to close on any alarm signal. (K6) is normally open dry contact which is programmed to close when the door is in motion or inhibited during a gravity close. LOW BATTERY INDICATOR TRANSFORMER SECONDARY PRIMARY (SHOWN AS LEFT HAND UNIT) 3

14 NOTE: All functions are independent of each other and do not require other control settings to be set at any certain configuration. Switch 4 is not used but must be set in the off position in order for the operator to work properly. For dip switch location refer to illustration on next page. ALARM DELAY TO CLOSE OPTIONAL CONTROL SETTINGS-FDO Dip switches S, S - and 2 set the Alarm Delay to Close time for the operator. The Alarm Delay to Close is the length of time between an active alarm signal received by the operator and when the operator begins to close the door. Refer to illustrations below for various settings. ON ON 0 SECOND DELAY 30 SECOND DELAY OFF OFF ON ON 45 SECOND DELAY 60 SECOND DELAY OFF OFF FIRE ALARM SYSTEM Select the alarm system being used. If the alarm is a normally open system then S,3 must be off. If the alarm is a normally close system then S,3 must be on. ON N.O. ALARM ON N.C. ALARM OFF OFF 4

15 OPTIONAL CONTROL SETTINGS-FDC NOTE: All functions are independent of each other and do not require other control settings to be set at any certain configuration. For dip switch location refer to illustration on next page. All switches are factory preset to the OFF position. S- ALARM DELAY TO CLOSE - Alarm Delay to Close is the length of time between an active alarm signal received by the operator and when the operator begins to close the door S-4 INFRARED EYES STATE - The operator will support LiftMaster Safety Photo Eyes when enabled, and ignore IR inputs when disabled. ON (0 SECOND DELAY) ON (IR'S ENABLED) OFF (0 SECOND DELAY) OFF (IR'S DISABLED) CONTROL SETTINGS-FDC S-2 MODE When Fire Door Mode Type I (Factory Default) is selected (S and 2 set to the OFF position), the control station is in standard B2 wiring, momentary contact to open, close and stop. When Fire Door Mode Type II is selected (S and 2 set to the ON position), the control station is in C2 wiring, momentary contact to open and stop, constant pressure to close with no open override. In addition, when Fire Door Mode Type II is selected the door will use Gravity Close (governed decent) on alarm. S-3 ALARM STATE - The operator can accept either a normally open or normally closed dry contact alarm input. DO NOT INDUCE VOLTAGE. ON (FIRE DOOR MODE TYPE II) ON (N.C. ALARM) OFF (FIRE DOOR MODE TYPE I) OFF (N.O. ALARM) Dip Switch (S) Terminal Block (J) Terminal Block () NOTICE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 5 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense. Heat Sink 5

16 CONTROL CONNECTION DIAGRAM-FDO IMPORTANT NOTE: The 3-Button Control Station provided must be connected for operation. 3 BUTTON STATION OR 3 POSITION KEYSWITCH WITH SPRING RETURN TO CENTER AND STOP BUTTON STANDARD 2 OR MORE KEY-TEST Open Open Open Open Close Close Close Close Stop Stop Stop Stop Keyswitch SENSING DEVICE TO REVERSE OR STOP ALARM SYSTEM NO OR NC CONTACTS 5 6 Sensing Device 2 NC Contacts Must set DIP switch #3 (S,3) to ON. 2 NO Contacts Must set DIP switch #3 (S,3) to OFF. STROBE LIGHT/SPEAKER WIRING 5 7 TB Strobe Light Speaker IMPORTANT: All inputs must be contact only! This includes: Alarm Inputs, Control Inputs, Sensing Edges and Sensing Devices. For any other devices not mentioned please consult the factory. CONTROL CONNECTION DIAGRAM-FDC IMPORTANT NOTE: The 3-Button Control Station provided must be connected for operation. 3 BUTTON STATION AND SYSTEM TEST KEY-TEST Open Close 5 24 Low Battery Indicator ALARM SYSTEM NO OR NC CONTACTS 2 NC Contacts Must set DIP switch #3 (S,3) to ON. 2 NO Contacts Must set DIP switch #3 (S,3) to OFF. SENSING DEVICE TO REVERSE OR STOP Stop Keyswitch 5 6 Sensing Device STROBE LIGHT WIRING TB 2 8 Installer supplied jumper , The Chamberlain Group, Inc B All Rights Reserved 24V Strobe

FIRE DOOR OPERATOR LOGIC BOARD REPLACEMENT KIT K A-600

FIRE DOOR OPERATOR LOGIC BOARD REPLACEMENT KIT K A-600 FIRE DOOR OPERATOR LOGI BOARD REPLAEMENT KIT K79-13493A-600 APPLIATI Replacement of logic board for model FDO-AU operator with fi rmware version 600. INSTALLATI REMOVE A AND D POWER 1. Disconnect A power

More information

MODEL K B-360/-500

MODEL K B-360/-500 MODEL K79-13493B-360/-500 Logic Board Replacement Kit APPLIATI REQUIREMENTS: Model FDOB operator with charge circuit board incorporating firmware versions 06-FDOB-360 or 06-FDOB-500. FUNTI: Replacement

More information

LMPLC OWNER S MANUAL MODEL FDCL ADVANCED LOGIC INDUSTRIAL DUTY FIRE DOOR OPERATOR 2 YEAR WARRANTY LMPLC CONTROL NOT FOR RESIDENTIAL USE

LMPLC OWNER S MANUAL MODEL FDCL ADVANCED LOGIC INDUSTRIAL DUTY FIRE DOOR OPERATOR 2 YEAR WARRANTY LMPLC CONTROL NOT FOR RESIDENTIAL USE OWNER S MANUAL MODEL FDCL ADVANCED LOGIC INDUSTRIAL DUTY FIRE DOOR OPERATOR LMPLC CONTROL LMPLC CONTROL WIRED YEAR WARRANTY Serial # (located on electrical box cover) NOT FOR RESIDENTIAL USE B6 Installation

More information

LMPLC OWNER S MANUAL MODEL FDCL. B2 Wiring ADVANCED LOGIC INDUSTRIAL DUTY FIRE DOOR OPERATOR 2 YEAR WARRANTY LMPLC CONTROL NOT FOR RESIDENTIAL USE

LMPLC OWNER S MANUAL MODEL FDCL. B2 Wiring ADVANCED LOGIC INDUSTRIAL DUTY FIRE DOOR OPERATOR 2 YEAR WARRANTY LMPLC CONTROL NOT FOR RESIDENTIAL USE OWNER S MANUAL MODEL FDCL ADVANCED LOGIC INDUSTRIAL DUTY FIRE DOOR OPERATOR LMPLC CONTROL LMPLC CONTROL WIRED B Wiring YEAR WARRANTY Serial # (located on electrical box cover) NOT FOR RESIDENTIAL USE B6

More information

FUNCTION: Allows existing Logic Control Version 2.0 or 2.0 Rev. B board in field to be replaced with new Logic Control Version 2.0 Rev. B.

FUNCTION: Allows existing Logic Control Version 2.0 or 2.0 Rev. B board in field to be replaced with new Logic Control Version 2.0 Rev. B. LOGIC CTROL VER. 2.0 Rev. B PCB BOARD REPLACEMENT KIT APPLICATI REQUIREMENTS: This modification is available to models T, GT, APT, J, H, GH, SD and GSD standard door operators with Logic Control Board

More information

LMPLC COOKSON OWNER'S MANUAL FDO A & B SOLID STATE INDUSTRIAL DUTY FIRE DOOR OPERATOR. B2/C2 Wiring 2 YEAR WARRANTY FDO 1/2 HP FDO A & B

LMPLC COOKSON OWNER'S MANUAL FDO A & B SOLID STATE INDUSTRIAL DUTY FIRE DOOR OPERATOR. B2/C2 Wiring 2 YEAR WARRANTY FDO 1/2 HP FDO A & B COOKSON OWNER'S MANUAL FDO A & B SOLID STATE INDUSTRIAL DUTY FIRE DOOR OPERATOR LMPLC CONTROL LMPLC CONTROL WIRED B/C Wiring FDO / HP FDO A & B FDO HP FDO A & B YEAR WARRANTY Serial # (located on electrical

More information

LMPLC EES SERIES COMMERCIAL/INDUSTRIAL DUTY EGRESS DOOR OPERATOR. B2/C2 Wiring 2 YEAR WARRANTY LMPLC CONTROL NOT FOR RESIDENTIAL USE.

LMPLC EES SERIES COMMERCIAL/INDUSTRIAL DUTY EGRESS DOOR OPERATOR. B2/C2 Wiring 2 YEAR WARRANTY LMPLC CONTROL NOT FOR RESIDENTIAL USE. EES SERIES COMMERCIAL/INDUSTRIAL DUTY EGRESS DOOR OPERATOR LMPLC CONTROL LMPLC CONTROL WIRED B2/C2 Wiring 2 YEAR WARRANTY Serial # Box NOT FOR RESIDENTIAL USE Installation Date TABLE OF CONTENTS SAFETY

More information

FDO AU & BU LMPLC ADVANCED LOGIC COMMERCIAL/INDUSTRIAL DUTY DOOR OPERATOR. B2/C2 Wiring

FDO AU & BU LMPLC ADVANCED LOGIC COMMERCIAL/INDUSTRIAL DUTY DOOR OPERATOR. B2/C2 Wiring FDO AU & BU ADVANCED LOGIC COMMERCIAL/INDUSTRIAL DUTY DOOR OPERATOR LMPLC CONTROL LMPLC CONTROL WIRED B2/C2 Wiring THIS PRODUCT IS TO BE INSTALLED AND SERVICED BY A TRAINED DOOR SYSTEMS TECHNICIAN ONLY.

More information

FDO AU AND BU LMPLC ADVANCED LOGIC COMMERCIAL/INDUSTRIAL DUTY DOOR OPERATOR. B2/C2 Wiring

FDO AU AND BU LMPLC ADVANCED LOGIC COMMERCIAL/INDUSTRIAL DUTY DOOR OPERATOR. B2/C2 Wiring FDO AU AND BU ADVANCED LOGIC COMMERCIAL/INDUSTRIAL DUTY DOOR OPERATOR LMPLC CONTROL LMPLC CONTROL WIRED B2/C2 Wiring THIS PRODUCT IS TO BE INSTALLED AND SERVICED BY A TRAINED DOOR SYSTEMS TECHNICIAN ONLY.

More information

ADDENDUM MODEL S3 OPERATORS Models: SL/540/570/580/590 & SW420/470/490

ADDENDUM MODEL S3 OPERATORS Models: SL/540/570/580/590 & SW420/470/490 ADDENDUM MODEL S3 OPERATORS Models: SL/540/570/580/590 & SW420/470/490 This addendum is to be used in conjunction with the owner s manual included with this operator. Refer to this addendum for all programming

More information

C2 Wiring 2 YEAR WARRANTY NOT FOR RESIDENTIAL USE. Serial # Box. Installation Date. Wiring Type. See page 7 for other wiring configurations

C2 Wiring 2 YEAR WARRANTY NOT FOR RESIDENTIAL USE. Serial # Box. Installation Date. Wiring Type. See page 7 for other wiring configurations PLACE RATING LABEL HERE B6 O W N E R S M A N U A L FACTORY SET C Wiring See page 7 for other wiring configurations E G J EUREAN STYLE GEARHEAD DAMP ENVIRONMENT JACKSHAFT THE CHAMBERLAIN GROUP, INC. ELMHURST,

More information

MAPNET II Transceiver Installation Instructions

MAPNET II Transceiver Installation Instructions MAPNET II Transceiver Installation Instructions Introduction This publication describes the installation procedure for the following versions of the MAPNET II Transceiver card. 4120/4100-0110 MAPNET II

More information

IRRIGATION 810-3T-PLUS TRANSMITTER GUIDE

IRRIGATION 810-3T-PLUS TRANSMITTER GUIDE IRRIGATION 810-3T-PLUS TRANSMITTER GUIDE Pg. 2 HOT SHOT OVERVIEW 3 STANDARD OPERATION MODE 4 HOW TO CONTROL AND SHARE MULTIPLE S 5 TRANSMITTER FUNCTION SWITCH SETTINGS 6 OPERATING THE TEST BEACON 7 OPERATING

More information

Covers All 430, 440, 441 and CJ Series Advanced Security Systems.

Covers All 430, 440, 441 and CJ Series Advanced Security Systems. INSTALL GUIDE Covers All 430, 440, 441 and CJ Series Advanced Security Systems www.ultrastarters.com Technical Support: 866-698-5872 ext 0 support@ultrastarters.com FCC/ID Notice This device complies with

More information

FM SECURITY AND REMOTE START SYSTEM

FM SECURITY AND REMOTE START SYSTEM FM SECURITY AND REMOTE START SYSTEM INSTALLATION MANUAL BEFORE INSTALLING THIS PRODUCT PLEASE READ THIS INSTALLATION MANUAL THOROUGHLY!! This system is intended for installation on vehicles equipped with

More information

INSTALLATION MANUAL. Model: PLUS For Technical Assistance, please call (800) , or visit

INSTALLATION MANUAL. Model: PLUS For Technical Assistance, please call (800) , or visit R Vehicle Security INSTALLATION MANUAL Model: PLUS-4700 This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference;

More information

MEDIUM DUTY DOOR OPERATOR MODELS MT5011U & BMT5011U

MEDIUM DUTY DOOR OPERATOR MODELS MT5011U & BMT5011U MEDIUM DUTY DOOR OPERATOR MODELS MT0U & BMT0U INSTALLATION MANUAL Now with Built in Radio Receiver MHz Your model may look different than the model illustrated in this manual. YEAR WARRANTY Serial # (located

More information

HAZARDOUS (NEMA 7/9) INDUSTRIAL DUTY COMMERCIAL DOOR OPERATOR 2 YEAR WARRANTY. Serial # Box. Installation Date. Wiring Type

HAZARDOUS (NEMA 7/9) INDUSTRIAL DUTY COMMERCIAL DOOR OPERATOR 2 YEAR WARRANTY. Serial # Box. Installation Date. Wiring Type O W N E R S M A N U A L HAZARDOUS (NEMA 7/9) INDUSTRIAL DUTY COMMERCIAL DOOR OPERATOR 2 YEAR WARRANTY Serial # Box Installation Date Wiring Type TABLE OF CONTENTS SPECIFICATIONS Operator Dimensions.................................

More information

COOKSON OWNER'S MANUAL

COOKSON OWNER'S MANUAL COOKSON OWNER'S MANUAL FDO-A10 INDUSTRIAL DUTY FIRE DOOR OPERATOR R L I S T E D 3040233 US CONTROL PANEL SERIAL# OPERATOR SERIAL# 9001.DWG ECN 0959 REV 4 SPECIFICATIONS MOTOR TYPE:...INTERMITTENT HORSEPOWER:...1/8

More information

CSI-100 Installation Instructions

CSI-100 Installation Instructions CSI-100 Installation Instructions Installation Precautions: Roll down window to avoid locking keys in vehicle during installation Avoid mounting components or routing wires near hot surfaces Avoid mounting

More information

Vehicle Security System

Vehicle Security System Installation Instructions Vehicle Security System PROFESSIONAL INSTALLATION STRONGLY RECOMMENDED Installation Precautions: Roll down window to avoid locking keys in vehicle during installation Avoid mounting

More information

Security and Keyless Entry Installation Guide ca 1051

Security and Keyless Entry Installation Guide ca 1051 PROFESSIONAL SERIES Security and Keyless Entry Installation Guide ca 1051 ca1051 rev B. 2011 Audiovox Electronics Corporation. All rights reserved. 1 Table of Contents Before You Begin... 3 Wire Connection

More information

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN SYMBOL LEGEND DANGER THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN WARNING THIS WARNS THAT MATERIALS MAY BE DAMAGED IF APPROPRIATE PRECAUTIONS ARE NOT

More information

MEDIUM DUTY DOOR OPERATOR MODELS MJ5011U, MH5011U, MHS5011U, & MGJ5011U

MEDIUM DUTY DOOR OPERATOR MODELS MJ5011U, MH5011U, MHS5011U, & MGJ5011U MEDIUM DUTY DOOR OPERATOR MODELS MJ0U, MH0U, MHS0U, & MGJ0U INSTALLATION MANUAL Now with Built in Radio Receiver MHz Your model may look different than the model illustrated in this manual. YEAR WARRANTY

More information

Product Overview. Product Identification. Amps One CT Two CTs Three CTs

Product Overview. Product Identification. Amps One CT Two CTs Three CTs AH06 (optional mounting bracket for small, medium, and large CTs) DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable

More information

Digital/Analog Amplifiers Installation Instructions

Digital/Analog Amplifiers Installation Instructions Digital/Analog Amplifiers Installation Instructions Introduction This publication describes the installation procedure for the 4100U and 4100ES Fire Alarm Control Panels (FACP) family of digital and analog

More information

Installation Instructions for VTU

Installation Instructions for VTU Installation Instructions for VTU 1 Introduction This installation manual covers the installation of the Vehicle Tracking Unit (VTU). This manual is for the professional and novice installer and should

More information

Programmable Logic Controller. Mat Nor Mohamad

Programmable Logic Controller. Mat Nor Mohamad Programmable Logic Controller Mat Nor Mohamad Relays Electromagnetic Control Relays The PLC's original purpose was the replacement of electromagnetic relays with a solid-state switching system that could

More information

Audio Operator Interface Installation Instructions

Audio Operator Interface Installation Instructions Audio Operator Interface Installation Instructions Introduction This publication describes the installation procedure for the following: 4100-1243 Microphone 4100-1244 Remote Microphone 4100-1252 Audio

More information

JBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER

JBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER JBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER JBE LED Dimming Controller for 110V* & 220V/ 240V AC LED Systems Thank you for purchasing high quality

More information

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL INSTALLATION INSTRUCTIONS AND OPERATION MANUAL - 1/3, 1/2, 3/4hp UL325-2010 Compliant Commercial and Industrial Door Operator Logic Control Duty Cycle 20 Cycles per Hour IMPORTANT INSTALLATION INSTRUCTIONS

More information

2 WAY REMOTE STARTER & ALARM SYSTEM INSTALLATION GUIDE FCC ID NOTICE

2 WAY REMOTE STARTER & ALARM SYSTEM INSTALLATION GUIDE FCC ID NOTICE REV. ARS. WAY REMOTE STARTER & ALARM SYSTEM INSTALLATION GUIDE FCC ID NOTICE This device complies with Part 5 of the FCC rules. Operation is subject to the following conditions:. This device may not cause

More information

GLM SERIES CONTROL Users Manual Rev:

GLM SERIES CONTROL Users Manual Rev: GLM SERIES CONTROL Users Manual Rev: 808062 Connecting Power Page 2 Motor Terminal Wiring Diagrams Page 3 Getting Started / Setup Page 4 1. Obstruction Detection Devices Page 4 2. Checking Power and Direction

More information

Topcon X30 Display Kit Installation Manual 54VT-TC-X30

Topcon X30 Display Kit Installation Manual 54VT-TC-X30 54VT-TC-X30 Topcon X30 Display Kit Installation Manual Printed in Canada Copyright 2010 by NORAC Systems International Inc. Reorder P/N: 54VT-TC-X30-INST Rev D (Topcon X30 Display Kit) NOTICE: NORAC Systems

More information

Proper installation of this product requires the installer to have a good understanding of automotive electronics, systems and procedures.

Proper installation of this product requires the installer to have a good understanding of automotive electronics, systems and procedures. ENGINEERING COMPANY INC. 5 Winthrop Road Chester, Connecticut 0642-0684 Phone: (860) 526-9504 Fax: (860) 525-4078 Internet: www.whelen.com Sales e-mail: autosale@whelen.com Canadian Sales e-mail: autocan@whelen.com

More information

Expansion Signal (XSIG) Card Installation Instructions

Expansion Signal (XSIG) Card Installation Instructions Expansion Signal (XSIG) Card Installation Instructions Introduction This publication describes the installation procedure for the Expansion Signal (XSIG) Card (4100-5116). This product is compatible with

More information

INTERFACE PART NUMBER NOTES

INTERFACE PART NUMBER NOTES 2000 Saturn S-Series ALARM REMOTE START WIRING WIRE COLOR LOCATION 12V CONSTANT RED Ignition Harness STARTER YELLOW Ignition Harness IGNITION PINK Ignition Harness ACCESSORY ORANGE Ignition Harness SECOND

More information

APOLLO Gate Operators, Inc.

APOLLO Gate Operators, Inc. APOLLO Gate Operators, Inc. Model 3500ETL/3600ETL Commercial Swing Gate Operator INSTALLATION MANUAL 01/08 CONTENTS IMPORTANT SAFETY INSTRUCTIONS. 3 Applications... 4 Pre-Installation Checklist... 5 Parts

More information

CSI-300 Installation Instructions

CSI-300 Installation Instructions CSI-300 Installation Instructions Kit Contents Installation Precautions: Roll down window to avoid locking keys in vehicle during installation Avoid mounting components or routing wires near hot surfaces

More information

SKC400U SLIDING GATE OPENER OWNER S MANUAL

SKC400U SLIDING GATE OPENER OWNER S MANUAL SKC400U SLIDING GATE OPENER OWNER S MANUAL IMPORTANT SAFTEY INFORMATION Installing the SKC400U Gate Opener requires wiring of standard 110V electrical lines. This should only be performed by a trained

More information

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN SYMBOL LEGEND DANGER THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN WARNING THIS WARNS THAT MATERIALS MAY BE DAMAGED IF APPROPRIATE PRECAUTIONS ARE NOT

More information

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL INSTALLATION INSTRUCTIONS AND OPERATION MANUAL - 1/3, 1/2, 3/4hp UL325-2010 Compliant Commercial and Industrial Door Operator Logic Control Duty Cycle 20 Cycles per Hour IMPORTANT INSTALLATION INSTRUCTIONS

More information

CS-865RKE Series II REMOTE KEYLESS ENTRY SYSTEM

CS-865RKE Series II REMOTE KEYLESS ENTRY SYSTEM INTRODUCTION: CS-865RKE Series II REMOTE KEYLESS ENTRY SYSTEM INSTALLATION & OPERATING INSTRUCTIONS CONGRATULATIONS on your choice of a Remote Keyless Entry System by Crimestopper Security Products Inc.

More information

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL INSTALLATION INSTRUCTIONS AND OPERATION MANUAL Commercial and Industrial Fire Door Operator Logic Control Restricted Duty Fire Door Operators IMPORTANT INSTALLATION INSTRUCTIONS WARNING To reduce the risk

More information

INSTALLATION GUIDE. FCC ID NOTICE

INSTALLATION GUIDE.  FCC ID NOTICE REV.5 RS. ADVANCED REMOTE STARTER INSTALLATION GUIDE www.security.soundstream.com FCC ID NOTICE This device complies with Part 5 of the FCC rules. Operation is subject to the following conditions:. This

More information

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL INSTALLATION INSTRUCTIONS AND OPERATION MANUAL UL325-2010 Compliant Commercial and Industrial Door Operator Logic Control Continuous Duty IMPORTANT INSTALLATION INSTRUCTIONS WARNING To reduce the risk

More information

NEMA 1, NEMA 4X and Chassis Mount Adjustable Speed Controls for DC Motors

NEMA 1, NEMA 4X and Chassis Mount Adjustable Speed Controls for DC Motors Made in the U.S.A. NEMA 1, NEMA 4X and Chassis Mount Adjustable Speed Controls for DC Motors Nema Enclosed DC Control Specifications Catalog Number BC140 or Features BC138 BC139 BC140-FBR BC154 BC160 BCWD140

More information

FM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017

FM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017 FM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017 Maxi-Tronic, Inc. 417 Wards Corner Road Loveland, OH 45140 513.398.2500 800.659.8250 FAX: 513.398.2536 info@maxitronic.com

More information

Model APS-101N Installation Manual

Model APS-101N Installation Manual Programmable Features Model APS-101N Installation Manual Select By Operating Transmitter Press Lock Button Press Unlock Button Siren Indications 1 Chirp 2 Chirps Factory Default 1) Arming Method Passive

More information

MEDIUM DUTY DOOR OPERATOR MODELS MJ5011U, MH5011U, MHS5011U, & MGJ5011U

MEDIUM DUTY DOOR OPERATOR MODELS MJ5011U, MH5011U, MHS5011U, & MGJ5011U MEDIUM DUTY DOOR OPERATOR MODELS MJ0U, MH0U, MHS0U, & MGJ0U INSTALLATION MANUAL Now with Built in Radio Receiver MHz Your model may look different than the model illustrated in this manual. YEAR WARRANTY

More information

LED/Switch Modules Installation Instructions

LED/Switch Modules Installation Instructions LED/Switch Modules Installation Instructions Introduction This publication describes the installation procedure for the 4100-1288 LED/Switch Controller Card and the associated 4100-1275 to 1278, 4100-1280

More information

TC26-B Vehicle Sensor

TC26-B Vehicle Sensor Section 1 General Description The Model TC26-B is a microprocessor controlled vehicle sensor with a variable range. It is designed to trigger the operation of a traffic controller. The TC26-B will only

More information

OnCommand Troubleshooting Guide Hayward Industries

OnCommand Troubleshooting Guide Hayward Industries OnCommand Troubleshooting Guide 2010 Hayward Industries Table of Contents Safety Precautions Page 1 Overview Pages 2-5 Software Troubleshooting Page 6 Local Display Pages 7-8 Relays Pages 9-10 Heaters

More information

VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL 1. INTRODUCTION VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL This MCU controlled Step Down DC-DC Converter has a digitally adjustable output in 0.2V increments. This

More information

OWNER'S MANUAL. C2 Wiring SOLID STATE INDUSTRIAL DUTY DOOR OPERATOR 2 YEAR WARRANTY LOGIC CONTROL NOT FOR RESIDENTIAL USE

OWNER'S MANUAL. C2 Wiring SOLID STATE INDUSTRIAL DUTY DOOR OPERATOR 2 YEAR WARRANTY LOGIC CONTROL NOT FOR RESIDENTIAL USE OWNER'S MANUAL GH SOLID STATE INDUSTRIAL DUTY DOOR OPERATOR LOGIC CONTROL LFACTORY SET C Wiring See pages & for other wiring configurations YEAR WARRANTY Serial # (located on electrical box cover) NOT

More information

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL INSTALLATION INSTRUCTIONS AND OPERATION MANUAL NEMA 4X UL325-2010 Compliant Commercial and Industrial Door Operator Logic Control Continuous Duty IMPORTANT INSTALLATION INSTRUCTIONS WARNING To reduce the

More information

YG101 SWING GATE OPENER OWNER S MANUAL

YG101 SWING GATE OPENER OWNER S MANUAL YG101 SWING GATE OPENER OWNER S MANUAL IMPORTANT SAFTEY INFORMATION Installing the YG101 Gate Opener requires wiring of standard 110V electrical lines. This should only be performed by a trained technician.

More information

VEHICLE SECURITY SYSTEM INSTALLATION MANUAL

VEHICLE SECURITY SYSTEM INSTALLATION MANUAL VEHICLE SECURITY SYSTEM WITH REMOTE START & NETWORK INTERFACE INSTALLATION MANUAL BEFORE INSTALLING THIS PRODUCT PLEASE READ THIS INSTALLATION MANUAL THOROUGHLY!! Before You Begin This system is intended

More information

e-ask electronic Access Security Keyless-entry

e-ask electronic Access Security Keyless-entry e-ask electronic Access Security Keyless-entry Multiplex System Multiplex System Installation & Instructions (UM15 ~ 22272-03) Table of Contents Introduction... 1 Standard e-fob Operation and Features...

More information

MM1 Installation Instructions

MM1 Installation Instructions MM1 Installation Instructions PROFESSIONAL INSTALLATION STRONGLY RECOMMENDED Installation Precautions: Roll down window to avoid locking keys in vehicle during installation Avoid mounting components or

More information

TROUBLESHOOTING GUIDE FOR HEAT PUMP BOOSTERS MODELS: HPB11, HPB15, & HPB22

TROUBLESHOOTING GUIDE FOR HEAT PUMP BOOSTERS MODELS: HPB11, HPB15, & HPB22 V3 TROUBLESHOOTING GUIDE FOR HEAT PUMP BOOSTERS MODELS: HPB11, HPB15, & HPB22 PREFACE This guide contains instructions for troubleshooting the Steffes Corporation room heating units: Models HPB 11, HPB

More information

Service Guide: Power Supply Model

Service Guide: Power Supply Model Service Guide: Supply Model 153941 Note The Supply, converts, regulates and distributes electric power from the electrical mains supply to components installed on Midmark Dental Chairs. Contents: Accessing

More information

PM300E Voltage Regulator Instruction Manual

PM300E Voltage Regulator Instruction Manual PM300E Voltage Regulator Instruction Manual A Regal Brand 1. INTRODUCTION The PM300E voltage regulator is an encapsulated electronic voltage regulator which controls the output of a brushless AC generator

More information

Service Guide: Power Supply Model

Service Guide: Power Supply Model Service Guide: Power Supply Model 153808 The Power Supply, converts, regulates and distributes electric power from the electrical mains supply to components installed on Midmark Dental Chairs. Contents:

More information

Advanced Instructions

Advanced Instructions Advanced Instructions Detailed wiring and installation instructions Monitor Battery #1 (and power the device) Connect the long red (positive) and black (negative) leads to the main battery. Many vehicles

More information

Cruising Charger Series OWNER S MANUAL

Cruising Charger Series OWNER S MANUAL R Cruising Charger Series OWNER S MANUAL ON BOARD BATTERY CHARGERS Models DC Amperage No. Of Banks Volts 2614A 5,10 Amps 2 Bank 12/12 2614A-230 2621A 5,5,10 Amps 3 Banks 12/12/12 2621A-230 2622A 10,10

More information

Model APS-510C Installation Manual Remote Control Vehicle Security System

Model APS-510C Installation Manual Remote Control Vehicle Security System Model APS-510C Installation Manual Remote Control Vehicle Security System Table Of Contents: Before You Begin Page 2 Wire Harnesses Quick View Page 3 Mounting Of The Major Components Page 4 8 Pin Power

More information

INSTALLATION AND INSTRUCTION MANUAL MODELS: PRO-T, PRO-TB

INSTALLATION AND INSTRUCTION MANUAL MODELS: PRO-T, PRO-TB INSTALLATION AND INSTRUCTION MANUAL MODELS: PRO-T, PRO-TB AUG, 2010 2 TABLE OF CONTENTS PAGE: VERIFICATION OF OPERATOR AND HARDWARE 3 SPECIFICATIONS 4 SAFETY INSTRUCTIONS 5 INSTALLATION 6 ELECTRICAL CONNECTIONS

More information

ONE-WAY DELUXE SECURITY SYSTEM

ONE-WAY DELUXE SECURITY SYSTEM ONE-WAY DELUXE SECURITY SYSTEM CONGRATULATIONS on your choice of a CrimeStopper Remote Security System. This booklet contains all the necessary information for using, and installing your security system.

More information

2004 Scion xa. PARKING LIGHTS (+) GREEN At Harness On Top Of Fuse Box DOOR TRIGGER (-) RED/WHITE In 9-Pin On Top Of Fuse Box

2004 Scion xa. PARKING LIGHTS (+) GREEN At Harness On Top Of Fuse Box DOOR TRIGGER (-) RED/WHITE In 9-Pin On Top Of Fuse Box ALARM REMOTE START WIRING WIRE COLOR LOCATION 12V CONSTANT WIRE WHITE/BLUE and Ignition Harness WHITE/RED STARTER WIRE BLACK Ignition Harness 12V IGNITION WIRE BLACK/RED Ignition Harness SECOND IGNITION

More information

Eaton Battery Charger Module Models ASY-0652 and ASY-0675 User s Guide

Eaton Battery Charger Module Models ASY-0652 and ASY-0675 User s Guide Eaton 9170 + Battery Charger Module Models ASY-0652 and ASY-0675 User s Guide Class A EMC Statements FCC Part 15 NOTE This equipment has been tested and found to comply with the limits for a Class A digital

More information

Series BFM Bulk Flow Monitor 1A FUSE RED LED RELAY. Part Number BFM-1 BFM-2 BFM-3 BFS-1

Series BFM Bulk Flow Monitor 1A FUSE RED LED RELAY. Part Number BFM-1 BFM-2 BFM-3 BFS-1 Series Bulk Flow Monitor Specifications - Installation and Operating Instructions Bulletin FL-1-4x 3/4 CONDUIT KNOCKOUTS BFS 1A FUSE RED LED RELAY 5-9/64 [130.45] TRANSFORMER 3[76.20] GREEN LED 7 [177.80]

More information

2 Way Security and Keyless Entry Installation Guide ca 1553

2 Way Security and Keyless Entry Installation Guide ca 1553 PROFESSIONAL SERIES 2 Way Security and Keyless Entry Installation Guide ca 1553 2012 Audiovox Electronics Corporation. All rights reserved. 1 Table of Contents Before You Begin... 3 Wire Connection Guide...

More information

OWNER'S MANUAL MODEL GH

OWNER'S MANUAL MODEL GH OWNER'S MANUAL MODEL GH LOGIC CTROL (VER..0) INDUSTRIAL DUTY DOOR OPERATOR LOGIC CTROL LFACTORY SET C Wiring See pages 6 thru 8 for other wiring configurations PATENT PENDING The Maintenance Alert System

More information

Single or Double 240VAC motor control for domestic and industrial gates and doors.

Single or Double 240VAC motor control for domestic and industrial gates and doors. COBO30 Double 240V Motor Drive Controller Features For 240Volt Motors Auto Closing Open Only Security Closing and Extended Lock Pulse (user selectable) Travel Timer Push Button Input Photo Cell Input Option

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS THANK YOU FOR CHOOSING KURYAKYN! Protect yourself and others from possible injury and property damage or loss. Pay close attention to all instructions, warnings, cautions, and notices regarding the installation,

More information

User Manual. 1. Introduction

User Manual. 1. Introduction User Manual 1. Introduction The Tactile Loop Controller has been designed to provide specific logic outputs from a patented EzyLoop Systems tactile Surface Mounted Switch Pad intended primarily for pedestrian

More information

OWNER'S MANUAL. MGJ (S-Series) MODEL INDUSTRIAL DUTY DOOR OPERATOR FOR USE WITH SS90 FIRE DOOR CONTROLLER 2 YEAR WARRANTY NOT FOR RESIDENTIAL USE

OWNER'S MANUAL. MGJ (S-Series) MODEL INDUSTRIAL DUTY DOOR OPERATOR FOR USE WITH SS90 FIRE DOOR CONTROLLER 2 YEAR WARRANTY NOT FOR RESIDENTIAL USE OWNER'S MANUAL MODEL MGJ (S-Series) INDUSTRIAL DUTY DOOR OPERATOR FOR USE WITH SS90 FIRE DOOR CONTROLLER YEAR WARRANTY Serial # (located on electrical box cover) NOT FOR RESIDENTIAL USE B6 Installation

More information

FROG-D 3P. FREQUENCY READOUT OF GENERATOR THREE PHASE GENERATOR DISPLAY MODELS: FDA700 for Delta Winding FDA710 for Star Winding

FROG-D 3P. FREQUENCY READOUT OF GENERATOR THREE PHASE GENERATOR DISPLAY MODELS: FDA700 for Delta Winding FDA710 for Star Winding Document Number: XE-FDA7PM-R0A FDA700 Rev160509 FROG-D 3P FREQUENCY READOUT OF GENERATOR THREE PHASE GENERATOR DISPLAY MODELS: FDA700 for Delta Winding FDA710 for Star Winding FIRE RESEARCH CORPORATION

More information

Battery Charger Retrofit Kit Q-DCCHG1 for DC Cabinet Retrofit Manual

Battery Charger Retrofit Kit Q-DCCHG1 for DC Cabinet Retrofit Manual Battery Charger Retrofit Kit Q-DCCHG1 for DC Cabinet Retrofit Manual 25500181 Rev. A0 415 Printed in U.S.A. Copyright 2015 Federal Signal Corporation Limited Warranty The Alerting and Notification Systems

More information

Instruction Manual. Model RAM-1000 UL & RAM-5500 UL For Class I, II, III, IV Vehicular Gate Operators. No Rev

Instruction Manual. Model RAM-1000 UL & RAM-5500 UL For Class I, II, III, IV Vehicular Gate Operators. No Rev Rev 060202 Instruction Manual Model RAM-1000 UL & RAM-5500 UL For Class I, II, III, IV Vehicular Gate Operators C No. 545327 US TABLE OF CONTENTS Important Safety Requirements & Instructions.......................................1,2

More information

SECTION MOTOR CONTROL

SECTION MOTOR CONTROL SECTION 26 24 19 MOTOR CONTROL PART 1 - GENERAL 1.1 SECTION INCLUDES A. Manual motor starters B. Magnetic motor starters C. Combination magnetic motor starters D. Solid-state reduced voltage motor starters

More information

Figure 3-9. Right-Hand Port Connector Configuration. 1. Remove electrical power to the Hydraulic Control Unit.

Figure 3-9. Right-Hand Port Connector Configuration. 1. Remove electrical power to the Hydraulic Control Unit. Figure 3-9. Right-Hand Port Connector Configuration Extend and Retract Limit Switch Configuration (if required) 1. Remove electrical power to the Hydraulic Control Unit. WARNING: DO NOT REMOVE OR INSTALL

More information

MAXIGARD A2000 SPEED SWITCH. Introduction

MAXIGARD A2000 SPEED SWITCH. Introduction A107-05, Page 1 952-361-3026, INC. (Fax) 952-368-4129 327 LAKE HAZELTINE DRIVE, CHASKA, MN 55318 800-328-0738 MAXIGARD A2000 SPEED SWITCH Introduction The Maxigard A2000 Speed Switch is designed to monitor

More information

OWNER'S MANUAL MODEL GH 5HP HEAVY DUTY DOOR OPERATOR 2 YEAR WARRANTY. Serial # (located on electrical box cover) Installation Date.

OWNER'S MANUAL MODEL GH 5HP HEAVY DUTY DOOR OPERATOR 2 YEAR WARRANTY. Serial # (located on electrical box cover) Installation Date. FACTORY SET C Wiring OWNER'S MANUAL MODEL GH 5HP HEAVY DUTY DOOR OPERATOR See page 8 for other wiring configurations YEAR WARRANTY Serial # (located on electrical box cover) WARNING: This product can expose

More information

Vehicle Security System

Vehicle Security System Installation Instructions Vehicle Security System PROFESSIONAL INSTALLATION STRONGLY RECOMMENDED Installation Precautions: Roll down window to avoid locking keys in vehicle during installation Avoid mounting

More information

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL INSTALLATION INSTUCTIONS AND OPEATION MANUAL FS-50 Series olling Fire Door Operators UL325-200 Compliant estricted Duty Operators COPOATION 3-3966-02(0) BY G ECN 5 5/9/ 2/0 IMPOTANT INSTALLATION INSTUCTIONS

More information

Proper installation of this product requires the installer to have a good understanding of automotive electronics, systems and procedures.

Proper installation of this product requires the installer to have a good understanding of automotive electronics, systems and procedures. ENGINEERING COMPANY INC. Route 45, Winthrop Road, Chester, Connecticut 0642 Phone: (860) 5269504 Fax: (860) 5264078 Internet: www.whelen.com Sales email: autosale@whelen.com Canadian Sales email: autocan@whelen.com

More information

VP-4124/VP-4124-E 24/48 VOLT DC SWITCHING POWER SUPPLY

VP-4124/VP-4124-E 24/48 VOLT DC SWITCHING POWER SUPPLY Issue 5 24/48 VOLT DC SWITCHING POWER SUPPLY INTRODUCTION These instructions provide the specifications, installation and maintenance information for the VP-4124 and VP-4124-E, 24/48 Volt Power Supplies.

More information

Aldi V4 & V V1.1 5/23/2014

Aldi V4 & V V1.1 5/23/2014 Aldi V4 & V5 2012 2013 V1.1 5/23/2014 Aldi Control Techniques SK Series VFD & Hussmann MX Series MicroChannel Condenser Equipment Operation Component Orientation Control Wiring Programming and Start Up

More information

A419 Series Electronic Temperature Controls with NEMA 1 or NEMA 4X Watertight Enclosures

A419 Series Electronic Temperature Controls with NEMA 1 or NEMA 4X Watertight Enclosures Installation Instructions Issue Date April 8, 2008 A419 Series Electronic Temperature Controls with NEMA 1 or NEMA 4X Watertight Enclosures Application IMPORTANT: The A419 Series Electronic Temperature

More information

Remote Start Installation Guide ca 4552

Remote Start Installation Guide ca 4552 PROFESSIONAL SERIES Remote Start Installation Guide ca 4552 ca4552. 2011 Audiovox Electronics Corporation. All rights reserved. 1 Before You Begin... 3 Wire Connection Guide... 4 4 Pin Main Harness...

More information

Installation Instructions TRACKNET TN-4003/4004

Installation Instructions TRACKNET TN-4003/4004 Installation Instructions TRACKNET TN-4003/4004 TABLE OF CONTENTS TABLE OF CONTENTS Introduction... 2 Installation Caution and Warnings... 3 Control Module and Components... 3-4 Mounting Location...4-5

More information

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor World Leader in Modular Torque Limiters Installation and Maintenance Instructions PTM-4 Load Monitor 1304 Twin Oaks Street Wichita Falls, Texas 76302 (940) 723-7800 Fax: (940) 723-7888 E-mail: sales@brunelcorp.com

More information

Installation Instructions

Installation Instructions 00A0, 0A0-0A0 080A00 08A00 For Use With Vertical EconoMi$ert IV or EconoMi$ert Only SMALL ROOFTOP UNITS ACCESSORY VERTICAL EXHAUST GAS HEATING/ELECTRIC COOLING, ELECTRIC COOLING, AND HEAT PUMP UNITS TO5TON

More information

Programmable 8 Channel Injector Driver Module

Programmable 8 Channel Injector Driver Module Overview: Programmable 8 Channel Injector Driver Module 554-142 The 8 channel fuel injector driver module allows for an input signal from any ECU to be changed into a user selectable peak and hold current.

More information

Installation and Operating Manual

Installation and Operating Manual MOTORS AND DRIVES SIGNAL ISOLATOR Accessory for BC204 Regenerative Drive Installation and Operating Manual 4/2000 MN1387 TABLE OF CONTENTS Section Page i. Safety Warning..........................................................

More information

Visit our web site at AMR LS-3000, LS-3010 & LS-3020 BELT SLIP/SEQUENCE CONTROL INSTALLATION AND SETUP INSTRUCTIONS

Visit our web site at   AMR LS-3000, LS-3010 & LS-3020 BELT SLIP/SEQUENCE CONTROL INSTALLATION AND SETUP INSTRUCTIONS AMR INC. DESIGN & MANUFACTURING FOR MINING WORLDWIDE P.O. BOX 234, ROCKY GAP, VA 24366 PHONE (276)928-1712 FAX (276)928-1814 Email sales@americanmineresearch.com Visit our web site at www.americanmineresearch.com

More information

ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI

ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI II 1400-6 ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI ACSI 1426-04-AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1092, REV. C INSTALLATION For C-UL Listed applications,

More information

SFGH-100SC SIREN & LIGHT SYSTEM Installation & Operation

SFGH-100SC SIREN & LIGHT SYSTEM Installation & Operation SFGH-100SC SIREN & LIGHT SYSTEM Installation & Operation Rev.7/15 The SFGH-100SC is a precision built, full function 100-watt siren system that incorporates both an alternating headlight and brake light

More information