Altech UL508. Typical UL508 Application. Power Circuit of a UL508A Panel

Size: px
Start display at page:

Download "Altech UL508. Typical UL508 Application. Power Circuit of a UL508A Panel"

Transcription

1 Typical UL508 Application Power Circuit of a UL508A Panel Altech's V-EA UL508 Manual Motor Controllers are approved for Group Installations Disclaimer: This an application example. Installation should be done by a qualified electrician under the guidance of UL/NEC specifications.. Altech UL508 Altech Corp. 35 Royal Road Flemington, NJ Phone (908) FAX (908)

2 Altech UL508 V-EA Series 508 listed E37938 C22.2 No. certified LR39 UL508 Listed Manual Motor Controller Suitable as Motor Disconnect DIN Rail Mounted 7.5mm width per pole Thermal Magnetic 80Y/277V AC, 50/Hz ka Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line AC General Use AC Resistance AC Discharge Lamps (Ballast) AC Incandescent Lamps (Tungsten) Voltage Rating Short Circuit Withstand Rating (UL/CSA - Ratings) Group Short Circuit Withstand Rating (UL/CSA - Ratings) Interrupting Capacity (VDE - Ratings) Calibration Temperature Terminal Size Acceptability Terminal Torque Terminal Protection Degree Horse Power Ratings Mechanical Endurance Ratings 80Y/277VAC A: pole - 2VDC; 2 Pole - 80VDC 30-A: pole - 2VDC; 2 Pole - VDC 0.3-A (RC): ka with UL-listed RK5 back-up fuse or MCCB 0.3-A (RC): ka; 3-A (RC): 5kA no branch circuit protection required A (RC): ka 0 C ( F) Top: 8-3 AWG; Bottom: 8-2 AWG 20 lb.in. IP20 see page 3 see page 35 SHORT CIRCUIT WITHSTAND RATINGS FOR V-EA MANUAL MOTOR CONTROLLER Backup UL-Listed UL-Listed No BCP Trip Protection RK5-Fuse MCCB Required Curve Amp Range up to ka up to ka up to: all A xrc* xrc* ka min 5A, max 70A min 5A, max 70A all 2-30/32A xrc* xrc* 5kA max 25A max 25A all 0-50A xrc* xrc* 5kA max 200A max 200A all / 63A xrc* xrc* 5kA max 250A max 250A *up to nearest rated current 20 Altech Corp. 35 Royal Road Flemington, NJ Phone (908) FAX (908)

3 Seconds Time t Minutes x -2-2 x -3 Z B CG D E Time versus Current Trip Curve For the exact trip curve, please refer to pages Dimensions in mm side view 35 mm (.38 in.) mm (2.76 in.) POLE 2 POLE 3 POLE 9.5 mm (3. in.) 9.5 mm (3. in.) 9.5 mm (3. in.) Trip-Characteristics* 7.5 mm (0.69 in.) 35 mm (.38 in.) Applications 52.5 mm (2.07 in.) Characteristic Trip Boundaries Thermal Trip Must not Trip>0ms Must Trip <hr Must not Trip>0ms B-Characteristics.3xRC.5xRC 3xRC 5xRC C-Characteristics.3xRC.5xRC 5xRC xrc D-Characteristics.3xRC.5xRC xrc 6xRC E-Characteristics.05xRC.35xRC xrc 8xRC G-Characteristics Magnetic Trip Must Trip at 0ms.05xRC.35xRC 8xRC xrc Z-Characteristics.05xRC.35xRC 2xRC 3xRC Lighting Wiring Protection Control Circuits Business Equipment Appliances Transformers Power Supplies Heaters *The value of each characteristic is shown vertically beneath its corresponding heading. Warning! This information should only be used as a selection guide.the use of a Miniature Circuit Breaker/Manual Motor Controller in an application with a certaintrip-characteristic always requires prototype testing! It is the responsibility of the circuit design engineer to select the appropriate Miniature Circuit Breaker/Manual Motor Controller for his specific application. Altech Corp. 35 Royal Road Flemington, NJ Phone (908) FAX (908) General Low Inrush Motors High Inrush High Efficiency General Electronics Solenoid Semiconductors Components/ devices with low surgecurrent and short circuit withstand capabilities Reactive Load 2Altech UL508

4 Altech UL508 B-Trip Characteristic UL508 Listed E37938 Standard Pack: 2.68kg (3.7 lb.) 0A - 63A.92kg (.23 lb.) Application Examples: Business equipment, wiring protection, lighting, appliances, control circuits, some motors and some electronic applications. Relatively long thermal trip delay but low magnetic trip point..0a BU.6A BU.6 2.0A BU2 2.5A BU A BU3 3.5A BU3.5.0A BU 5.0A BU5 6.0A BU6 8.0A NA A BU 2A NA 2.5A NA 3A BU3 5A BU5 6A BU6 20A BU20 25A BU25 30A BU30 32A BU32 0A BU0 50A BU50 A BU 63A BU63 plus neutral.56kg (3. lb.) 0A - 63A.7kg (3.8 lb.).0a 2BNU.6A 2BNU.6 2.0A 2BNU2 2.5A 2BNU A 2BNU3 3.5A 2BNU3.5.0A 2BNU 5.0A 2BNU5 6.0A 2BNU6 8.0A NA A 2BNU 2A NA 2.5A NA 3A 2BNU3 5A 2BNU5 6A 2BNU6 20A 2BNU20 25A 2BNU25 30A 2BNU30 32A 2BNU32 0A 2BNU0 50A 2BNU50 A 2BNU 63A 2BNU63 Two Pole.68kg (3.7 lb.).0a 2BU.6A 2BU.6 2.0A 2BU2 2.5A 2BU A 2BU3 3.5A 2BU3.5.0A 2BU 5.0A 2BU5 6.0A 2BU6 8.0A NA A 2BU 2A NA 2.5A NA 3A 2BU3 5A 2BU5 6A 2BU6 20A 2BU20 25A 2BU25 30A 2BU30 32A 2BU32 0A 2BU0 50A 2BU50 A 2BU 63A 2BU63 Three Pole Standard Pack:.68kg (3.7 lb.).0a 3BU.6A 3BU.6 2.0A 3BU2 2.5A 3BU A 3BU3 3.5A 3BU3.5.0A 3BU 5.0A 3BU5 6.0A 3BU6 8.0A NA A 3BU 2A NA 2.5A NA 3A 3BU3 5A 3BU5 6A 3BU6 20A 3BU20 25A 3BU25 30A 3BU30 32A 3BU32 0A 3BU0 50A 3BU50 A 3BU 63A 3BU63 For ring tongue terminal version, replace U with R in part number. For example BR20 instead of BU Altech Corp. 35 Royal Road Flemington, NJ Phone (908) FAX (908)

5 C-Trip Characteristic Application Examples: Low inrush motors, lighting, wiring protection, appliances, business equipment, and control circuit applications. Relatively long thermal trip delay and medium magnetic trip point. UL508 Listed E37938 Standard Pack: 2.68kg (3.7 lb.) 0A - 63A.92kg (.23 lb.) 0.3A CU03 0.5A CU A CU075.0A CU.6A CU.6 2.0A CU2 2.5A CU A CU3 3.5A CU3.5.0A CU 5.0A CU5 6.0A CU6 8.0A CU8 A CU 2A NA 2.5A NA 3A CU3 5A CU5 6A CU6 20A CU20 25A CU25 30A CU30 32A CU32 0A CU0 50A CU50 A CU 63A CU63 plus neutral.56kg (3. lb.) 0A - 63A.7kg (3.8 lb.) 0.3A 2CNU03 0.5A 2CNU A 2CNU075.0A 2CNU.6A 2CNU.6 2.0A 2CNU2 2.5A 2CNU A 2CNU3 3.5A 2CNU3.5.0A 2CNU 5.0A 2CNU5 6.0A 2CNU6 8.0A 2CNU8 A 2CNU 2A NA 2.5A NA 3A 2CNU3 5A 2CNU5 6A 2CNU6 20A 2CNU20 25A 2CNU25 30A 2CNU30 32A 2CNU32 0A 2CNU0 50A 2CNU50 A 2CNU 63A 2CNU63 Two Pole.68kg (3.7 lb.) 0.3A 2CU03 0.5A 2CU A 2CU075.0A 2CU.6A 2CU.6 2.0A 2CU2 2.5A 2CU A 2CU3 3.5A 2CU3.5.0A 2CU 5.0A 2CU5 6.0A 2CU6 8.0A 2CU8 A 2CU 2A NA 2.5A NA 3A 2CU3 5A 2CU5 6A 2CU6 20A 2CU20 25A 2CU25 30A 2CU30 32A 2CU32 0A 2CU0 50A 2CU50 A 2CU 63A 2CU63 Three Pole Standard Pack:.68kg (3.7 lb.) For ring tongue terminal version, replace U with R in part number. For example BR20 instead of BU A 3CU03 0.5A 3CU A 3CU075.0A 3CU.6A 3CU.6 2.0A 3CU2 2.5A 3CU A 3CU3 3.5A 3CU3.5.0A 3CU 5.0A 3CU5 6.0A 3CU6 8.0A 3CU8 A 3CU 2A NA 2.5A NA 3A 3CU3 5A 3CU5 6A 3CU6 20A 3CU20 25A 3CU25 30A 3CU30 32A 3CU32 0A 3CU0 50A 3CU50 A 3CU 63A 3CU63 Altech Corp. 35 Royal Road Flemington, NJ Phone (908) FAX (908) Altech UL508

6 Altech UL508 D-Trip Characteristic UL508 Listed E37938 Standard Pack: 2.68kg (3.7 lb.) 0A - 63A.92kg (.23 lb.) Application Examples: High inrush motors, transformers, power supplies, heaters and reactive loads. Relatively long thermal trip delay and very high magnetic trip point. 0.3A DU03 0.5A DU A DU075.0A DU.6A DU.6 2.0A DU2 2.5A DU A DU3 3.5A DU3.5.0A DU 5.0A DU5 6.0A DU6 8.0A DU8 A DU 2A NA 2.5A NA 3A DU3 5A DU5 6A DU6 20A DU20 25A DU25 30A DU30 32A DU32 0A DU0 50A DU50 A DU 63A DU63 plus neutral.56kg (3. lb.) 0A - 63A.7kg (3.8 lb.) 0.3A 2DNU03 0.5A 2DNU A 2DNU075.0A 2DNU.6A 2DNU.6 2.0A 2DNU2 2.5A 2DNU A 2DNU3 3.5A 2DNU3.5.0A 2DNU 5.0A 2DNU5 6.0A 2DNU6 8.0A 2DNU8 A 2DNU 2A NA 2.5A NA 3A 2DNU3 5A 2DNU5 6A 2DNU6 20A 2DNU20 25A 2DNU25 30A 2DNU30 32A 2DNU32 0A 2DNU0 50A 2DNU50 A 2DNU 63A 2DNU63 Two Pole.68kg (3.7 lb.) 0.3A 2DU03 0.5A 2DU A 2DU075.0A 2DU.6A 2DU.6 2.0A 2DU2 2.5A 2DU A 2DU3 3.5A 2DU3.5.0A 2DU 5.0A 2DU5 6.0A 2DU6 8.0A 2DU8 A 2DU 2A NA 2.5A NA 3A 2DU3 5A 2DU5 6A 2DU6 20A 2DU20 25A 2DU25 30A 2DU30 32A 2DU32 0A 2DU0 50A 2DU50 A 2DU 63A 2DU63 Three Pole Standard Pack:.68kg (3.7 lb.) For ring tongue terminal version, replace U with R in part number. For example BR20 instead of BU A 3DU03 0.5A 3DU A 3DU075.0A 3DU.6A 3DU.6 2.0A 3DU2 2.5A 3DU A 3DU3 3.5A 3DU3.5.0A 3DU 5.0A 3DU5 6.0A 3DU6 8.0A 3DU8 A 3DU 2A NA 2.5A NA 3A 3DU3 5A 3DU5 6A 3DU6 20A 3DU20 25A 3DU25 30A 3DU30 32A 3DU32 0A 3DU0 50A 3DU50 A 3DU 63A 3DU63 2 Altech Corp. 35 Royal Road Flemington, NJ Phone (908) FAX (908)

7 E-Trip Characteristic Application Examples: High efficiency motors, which have exceedingly high inrush currents. Relatively short thermal trip delays and very high magnetic trip points. UL508 Listed E37938 Standard Pack: 2.68kg (3.7 lb.) 0A - 63A.92kg (.23 lb.) 0.3A EU03 0.5A EU A EU075.0A EU.6A EU.6 2.0A EU2 2.5A EU A EU3 3.5A EU3.5.0A EU 5.0A EU5 6.0A EU6 8.0A EU8 A EU 2A EU2 2.5A EU25 3A EU3 5A EU5 6A EU6 20A EU20 25A EU25 30A EU30 32A EU32 0A EU0 50A EU50 A EU 63A EU63 plus neutral.56kg (3. lb.) 0A - 63A.7kg (3.8 lb.) 0.3A 2ENU03 0.5A 2ENU A 2ENU075.0A 2ENU.6A 2ENU.6 2.0A 2ENU2 2.5A 2ENU A 2ENU3 3.5A 2ENU3.5.0A 2ENU 5.0A 2ENU5 6.0A 2ENU6 8.0A 2ENU8 A 2ENU 2A 2ENU2 2.5A 2ENU25 3A 2ENU3 5A 2ENU5 6A 2ENU6 20A 2ENU20 25A 2ENU25 30A 2ENU30 32A 2ENU32 0A 2ENU0 50A 2ENU50 A 2ENU 63A 2ENU63 Two Pole.68kg (3.7 lb.) 0.3A 2EU03 0.5A 2EU A 2EU075.0A 2EU.6A 2EU.6 2.0A 2EU2 2.5A 2EU A 2EU3 3.5A 2EU3.5.0A 2EU 5.0A 2EU5 6.0A 2EU6 8.0A 2EU8 A 2EU 2A 2EU2 2.5A 2EU25 3A 2EU3 5A 2EU5 6A 2EU6 20A 2EU20 25A 2EU25 30A 2EU30 32A 2EU32 0A 2EU0 50A 2EU50 A 2EU 63A 2EU63 Three Pole Standard Pack:.68kg (3.7 lb.) For ring tongue terminal version, replace U with R in part number. For example BR20 instead of BU A 3EU03 0.5A 3EU A 3EU075.0A 3EU.6A 3EU.6 2.0A 3EU2 2.5A 3EU A 3EU3 3.5A 3EU3.5.0A 3EU 5.0A 3EU5 6.0A 3EU6 8.0A 3EU8 A 3EU 2A 3EU2 2.5A 3EU25 3A 3EU3 5A 3EU5 6A 3EU6 20A 3EU20 25A 3EU25 30A 3EU30 32A 3EU32 0A 3EU0 50A 3EU50 A 3EU 63A 3EU63 Altech Corp. 35 Royal Road Flemington, NJ Phone (908) FAX (908) Altech UL508

8 Altech UL508 G-Trip Characteristic UL508 Listed E37938 Standard Pack: 2.68kg (3.7 lb.) 0A - 63A.92kg (.23 lb.) Application Examples: General industrial, including motors, some transformers, solenoids, control circuits, lighting and wiring. Meets the US trip norms with relatively short thermal trip delay and high magnetic trip point. 0.3A GU03 0.5A GU A NA 0.8A GU08.0A GU.6A GU.6 2.0A GU2 2.5A GU A GU3 3.5A GU3.5.0A GU 5.0A GU5 6.0A GU6 8.0A GU8 A GU 2A GU2 2.5A GU25 3A GU3 5A GU5 6A GU6 20A GU20 25A GU25 30A GU30 32A GU32 0A GU0 50A GU50 A GU 63A GU63 plus neutral.56kg (3. lb.) 0A - 63A.7kg (3.8 lb.) 0.3A 2GNU03 0.5A 2GNU A NA 0.8A 2GNU08.0A 2GNU.6A 2GNU.6 2.0A 2GNU2 2.5A 2GNU A 2GNU3 3.5A 2GNU3.5.0A 2GNU 5.0A 2GNU5 6.0A 2GNU6 8.0A 2GNU8 A 2GNU 2A 2GNU2 2.5A 2GNU25 3A 2GNU3 5A 2GNU5 6A 2GNU6 20A 2GNU20 25A 2GNU25 30A 2GNU30 32A 2GNU32 0A 2GNU0 50A 2GNU50 A 2GNU 63A 2GNU63 Two Pole.68kg (3.7 lb.) 0.3A 2GU03 0.5A 2GU A NA 0.8A 2GU08.0A 2GU.6A 2GU.6 2.0A 2GU2 2.5A 2GU A 2GU3 3.5A 2GU3.5.0A 2GU 5.0A 2GU5 6.0A 2GU6 8.0A 2GU8 A 2GU 2A 2GU2 2.5A 2GU25 3A 2GU3 5A 2GU5 6A 2GU6 20A 2GU20 25A 2GU25 30A 2GU30 32A 2GU32 0A 2GU0 50A 2GU50 A 2GU 63A 2GU63 Three Pole Standard Pack:.68kg (3.7 lb.) 0.3A 3GU03 0.5A 3GU A NA 0.8A 3GU08.0A 3GU.6A 3GU.6 2.0A 3GU2 2.5A 3GU A 3GU3 3.5A 3GU3.5.0A 3GU 5.0A 3GU5 6.0A 3GU6 8.0A 3GU8 A 3GU 2A 3GU2 2.5A 3GU25 3A 3GU3 5A 3GU5 6A 3GU6 20A 3GU20 25A 3GU25 30A 3GU30 32A 3GU32 0A 3GU0 50A 3GU50 A 3GU 63A 3GU63 For ring tongue terminal version, replace U with R in part number. For example BR20 instead of BU Altech Corp. 35 Royal Road Flemington, NJ Phone (908) FAX (908)

9 Z-Trip Characteristic UL508 Listed E37938 Standard Pack: 2.68kg (3.7 lb.) 0A - 63A.92kg (.23 lb.) Application Examples: Semiconductors, components which failshort (vs. fail-open), and components/devices with low surgecurrent and short circuit withstand capabilities. Relatively short thermal delay and very low magnetic trip point. 0.3A ZU03 0.5A ZU A ZU075.0A ZU.6A ZU.6 2.0A ZU2 2.5A ZU A ZU3 3.5A ZU3.5.0A ZU 5.0A ZU5 6.0A ZU6 8.0A ZU8 A ZU 2A ZU2 2.5A ZU25 3A ZU3 5A ZU5 6A ZU6 20A ZU20 25A ZU25 30A ZU30 32A ZU32 0A ZU0 * 50A ZU50 * plus neutral.56kg (3. lb.) 0A - 63A.7kg (3.8 lb.) 0.3A 2ZNU03 0.5A 2ZNU A 2ZNU075.0A 2ZNU.6A 2ZNU.6 2.0A 2ZNU2 2.5A 2ZNU A 2ZNU3 3.5A 2ZNU3.5.0A 2ZNU 5.0A 2ZNU5 6.0A 2ZNU6 8.0A 2ZNU8 A 2ZNU 2A 2ZNU2 2.5A 2ZNU25 3A 2ZNU3 5A 2ZNU5 6A 2ZNU6 20A 2ZNU20 25A 2ZNU25 30A 2ZNU30 32A 2ZNU32 0A 2ZNU0 * 50A 2ZNU50 * Two Pole.68kg (3.7 lb.) 0.3A 2ZU03 0.5A 2ZU A 2ZU075.0A 2ZU.6A 2ZU.6 2.0A 2ZU2 2.5A 2ZU A 2ZU3 3.5A 2ZU3.5.0A 2ZU 5.0A 2ZU5 6.0A 2ZU6 8.0A 2ZU8 A 2ZU 2A 2ZU2 2.5A 2ZU25 3A 2ZU3 5A 2ZU5 6A 2ZU6 20A 2ZU20 25A 2ZU25 30A 2ZU30 32A 2ZU32 0A 2ZU0 * 50A 2ZU50 * Three Pole Standard Pack:.68kg (3.7 lb.) For ring tongue terminal version, replace U with R in part number. For example BR20 instead of BU A 3ZU03 0.5A 3ZU A 3ZU075.0A 3ZU.6A 3ZU.6 2.0A 3ZU2 2.5A 3ZU A 3ZU3 3.5A 3ZU3.5.0A 3ZU 5.0A 3ZU5 6.0A 3ZU6 8.0A 3ZU8 A 3ZU 2A 3ZU2 2.5A 3ZU25 3A 3ZU3 5A 3ZU5 6A 3ZU6 20A 3ZU20 25A 3ZU25 30A 3ZU30 32A 3ZU32 0A 3ZU0 * 50A 3ZU50 * Altech UL508 Altech Corp. 35 Royal Road Flemington, NJ Phone (908) FAX (908)

10 Altech UL508 V-EA Trip Curves B Trip Curve C Trip Curve D Trip Curve V-EA-B Trip.0A Through A Rated Current.3-.5xI N x -2-2 x -3 Must Trip < hr = 5% RC Must Not Trip > hr = 3% RC V-EA-C Trip 0.3A Through A Rated Current.3-.5xI N x -2-2 x -3 Must Trip < hr = 5% RC Must Not Trip > hr = 3% RC V-EA-D Trip 0.3A Through A Rated Current.3-.5xI N x -2-2 x -3 Must Trip < hr = 5% RC Must Not Trip > hr = 3% RC V-EA-B Trip 3A Through 63A Rated Current.3-.5xI N 0 V-EA-C Trip 3A Through 63A Rated Current.3-.5xI N 0 V-EA-D Trip 3A Through 63A Rated Current.3-.5xI N x -2-2 x -3 Must Trip < hr = 5% RC Must Not Trip > hr = 3% RC 0. - x -2-2 x -3 Must Trip < hr = 5% RC Must Not Trip > hr = 3% RC 0. - x -2-2 x -3 Must Trip < hr = 5% RC Must Not Trip > hr = 3% RC B Magnetic Trip Parameters Rated current.0a to 63A.. Hold for a minimum of 0ms at surge of 3 times rated current. 2. Trip in under 0ms at 5 times rated current. C Magnetic Trip Parameters Rated current 0.3A to 63A.. Hold for a minimum of 0ms at surge of 5 times rated current. 2. Trip in under 0ms at times rated current. D Magnetic Trip Parameters Rated current 0.3A to 63A.. Hold for a minimum of 0ms at surge of times rated current. 2. Trip in under 0ms at 6 times rated current. 28 Altech Corp. 35 Royal Road Flemington, NJ Phone (908) FAX (908)

11 V-EA Trip Curves E Trip Curve G Trip Curve Z Trip Curve V-EA-E Trip 0.3A Through A Rated Current xI N 0 V-EA-G Trip 0.3A Through A Rated Current xI N 0 V-EA-Z Trip 0.3A Through A Rated Current xI N 0 Seconds Minutes 0. - x -2-2 x E0.3A-EA Must Trip < hr = 35% RC Must Not Trip > hr = 5% RC Seconds Minutes 0. - x -2-2 x -3 Must Trip = 25% Rated Current Must Not Trip < hr = 35% RC Must Not Trip > hr = 5% RC Must Not Trip = Rated Current x -2-2 x -3 Must Trip < hr = 35% RC Must Not Trip > hr = 5% RC V-EA-E Trip 2A Through A Rated Current xI N 0 V-EA-G Trip 2A Through 63A Rated Current xI N 0 V-EA-Z Trip 2.5A Through 32A Rated Current xI N 0 Seconds Minutes 0. - x -2-2 x Must Trip < hr = 35% RC Must Not Trip > hr = 5% RC E Magnetic Trip Parameters Rated Current, 0.3A to 50A ( ), /63A ( ). Magnetic Trip:. Hold for a minimum of 0ms at surge of times (A, times) rated current. 2. Trip in under 0ms at 8 times (A, times) rated current. Seconds Minutes 0. - x -2-2 x -3 Must Trip = 25% Rated Current Must Not Trip < hr = 35% RC Must Not Trip > hr = 5% RC Must Not Trip = Rated Current G Magnetic Trip Parameters Rated Current, 0.3A to 63A. Magnetic Trip:. Hold for a minimum of 0ms at surge of 8 times rated current. 2. Trip in under 0ms at times rated current x -2-2 x -3 Must Trip < hr = 35% RC Must Not Trip > hr = 5% RC Z Trip Parameters Rated Current, 0.3A to 32A. Magnetic Trip:. Hold for a minimum of 0ms at 2 times rated current. 2. Trip in under 0ms at 3 times rated current. Altech UL508 Altech Corp. 35 Royal Road Flemington, NJ Phone (908) FAX (908)

12 Altech UL508 Table HP : AMPERE RATINGS & HORSEPOWER RATING PHASE FLA & LRC CONVERTED TO TABLE HORSEPOWER (SEE NOTE #2) USE FLA & LRC RATINGS WHERE NO HP RATING IS GIVEN NOMINAL CIRCUIT VOLTAGE V-EA MOTOR MOTOR RATED NAMEPLATE NAMEPLATE VAC VAC VAC VAC VAC VAC CURRENT FLA STARTING/ (SEE NOTE #) RATING LRC RATING 0.30A 0.30A.80A 0.50A 0.50A 3.00A 0.75A 0.75A.35A 0.80A 0.80A.8A.0A.0A 6.0A.6A.6A 9.6A 2.0A 2.0A 2.0A /6hp /6hp /6hp 2.5A 2.5A 5.0A /6hp /6hp /6hp /6hp /hp 3.0A 3.0A 8.0A /6hp /6hp /hp /hp /3hp 3.5A 3.5A 2.0A /hp /hp /hp /3hp /3hp.0A.0A 2.0A /hp /3hp /3hp /3hp /3hp 5.0A 5.0A 30.0A /6hp /3hp /2hp /2hp /2hp /2hp 6.0A 6.0A 36.0A /hp /2hp /2hp /2hp 3/hp 3/hp 8.0A 8.0A 8.0A /3hp 3/hp 3/hp hp hp hp.0a.0a.0a /2hp hp hp /2hp /2hp 2hp 2.0A 2.0A 72.0A /2hp /2hp /2hp 2hp 2hp 2hp 2.5A 2.5A 75.0A /2hp /2hp /2hp 2hp 2hp 2hp 3.0A 3.0A 78.0A /2hp /2hp /2hp 2hp 2hp 2hp 5.0A 5.0A 90.0A 3/hp 2hp 2hp 2hp 3hp 3hp 6.0A 6.0A 96.0A hp 2hp 2hp 2hp 3hp 3hp 20.0A 20.0A 20.0A /2hp 3hp 3hp 3hp 3hp 3hp 25.0A 25.0A 50.0A 2hp 3hp 3hp 3hp 5hp 5hp 30.0A 30.0A 80.0A 2hp 3hp 3hp 5hp 5hp 5hp 32.0A 32.0A 92.0A 2hp 3hp 5hp 5hp 5hp 5hp 0.0A 0.0A 20.0A 3hp 5hp 7/2hp 7/2hp 7/2hp 7/2hp 50.0A 50.0A 300.0A 3hp 7/2hp hp hp hp hp.0a.0a 3.0A 5hp hp hp hp hp 5hp NOTE #: For AC motor circuit nameplate full load current, AC general-use loads, AC resistance loads, AC incandescent lamp (tungsten) loads, AC electric discharge lamp (ballast) loads. NOTE #2: Conversions per UL508 Table 5.2 and NFPA-70: National Electrical Code 2008 Tables and 30-25(A). Table HP 2: AMPERE RATING & HORSEPOWER RATING 3 PHASE & 2 PHASE - WIRE FLA & LRC RATINGS CONVERTED TO TABLE HORSEPOWER (SEE NOTE #2) USE FLA & LRC RATINGS WHERE NO HP IS LISTED V-EA MOTOR MOTOR VAC 0-80 RATED NAMEPLATE NAMEPLATE VAC VAC VAC (SEE NOTE #3) VAC CURRENT FLA STARTING/ Motor Design Motor Design Motor Design Motor Design Motor Design (SEE NOTE #) RATING LRC RATING B, C, D E B, C, D E B, C, D E B, C, D E B, C, D E 0.30A 0.30A 3.0A 0.50A 0.50A 5.0A 0.75A 0.75A 7.5A 0.80A 0.80A 8.0A.0A.0A.0A.6A.6A 6.0A /2hp /2hp 2.0A 2.0A 20.0A /2hp /2hp 3/hp 3/hp 2.5A 2.5A 25.0A /2hp /2hp /2hp /2hp /2hp /2hp hp hp 3.0A 3.0A 30.0A /2hp /2hp /2hp /2hp /2hp /2hp /2hp /2hp 3.5A 3.5A 35.0A /2hp /2hp 3/hp 3/hp 3/hp 3/hp 2hp 2hp.0A.0A 0.0A 3/hp 3/hp 3/hp 3/hp 3/hp 3/hp 2hp 2hp 5.0A 5.0A 2.0A /2hp /2hp hp hp hp hp hp hp 3hp 3hp 6.0A 6.0A 50.A /2hp /2hp hp hp hp hp /2hp /2hp 3hp 3hp 8.0A 8.0A 67.2A 3/hp 3/hp 2hp 2hp 2hp 2hp 2hp 2hp 5hp 5hp.0A.0A 8.0A hp hp 2hp 2hp 2hp 2hp 3hp 3hp 5hp 5hp 2.0A 2.0A 0.8A /2hp /2hp 3hp 3hp 3hp 3hp 3hp 3hp 7/2hp 7/2hp 2.5A 2.5A 5.0A /2hp /2hp 3hp 3hp 3hp 3hp 3hp 3hp 7/2hp 7/2hp 3.0A 3.0A 9.2A /2hp /2hp 3hp 3hp 3hp 3hp 3hp 3hp 7/2hp 7/2hp 5.0A 5.0A 26.0A 2hp 2hp 3hp 3hp 3hp 3hp 3hp 3hp hp hp 6.0A 6.0A 3.A 2hp 2hp 3hp 3hp 3hp 3hp 5hp 5hp hp hp 20.0A 20.0A 68.0A 3hp 3hp 5hp 5hp 5hp 5hp 5hp 5hp hp hp 25.0A 25.0A 2.0A 3hp 3hp 5hp 5hp 7/2hp 7/2hp 7/2hp 7/2hp 5hp 5hp 30.0A 30.0A 252.0A 5hp 5hp 5hp 5hp 7/2hp 7/2hp hp hp 20hp 20hp 32.0A 32.0A 268.8A 5hp 5hp 5hp 5hp hp hp hp hp 20hp 20hp 0.0A 0.0A 226.0A 5hp 5hp hp 7/2hp hp 7/2hp hp hp 30hp 20hp 50.0A 50.0A 282.5A 7/2hp 7/2hp 5hp hp 5hp hp 5hp hp 30hp 25hp.0A.0A 339.0A hp hp 5hp hp 20hp hp 20hp 5hp 0hp 30hp NOTE #: For AC motor circuit nameplate full load current, AC general-use loads, AC resistance loads, AC incandescent lamp (tungsten) loads, AC electric discharge lamp (ballast) loads. NOTE #2: Conversions per UL508 proposed Tables 5.2 and 5. and NFPA-70: National Electrical Code 2008 Tables 30-29, and 30-25B). 30 Altech Corp. 35 Royal Road Flemington, NJ Phone (908) FAX (908)

13 V-EA INTERNAL RESISTANCE Trip Characteristic Rated Current B C D E G Z (Amp) (Ohms) (Ohms) (Ohms) (Ohms) (Ohms) (Ohms) / / / / / Resistances listed are hot values, as opposed to cold start values. Operating voltage drop across the V-EA and power loss per pole can be approximated with basic formulas: V DROP = I OPERATING x R TABLE P LOSS P/P = I 2 OPERATING x R TABLE Voltage drops should be reviewed when V-EAs with high internal resistance are used (e.g., load voltage minimums). Power loss should be reviewed when V-EAs with high rated currents are used (e.g., enclosure heating). The listed V-EA internal resistance values should not be used in calculations of available short-circuit current downstream of the V-EA. The dynamic impedance of the V-EA under short-circuit conditions can vary significantly from internal resistance values in normal operation. LINE CURRENT FREQUENCY EFFECTS ON TRIP CURVES Frequency Effects on Magnetic Trip Curves Trip Trip Zone Trip Zone Trip Zone Trip Zone Trip Zone Curve At At At At At 6 2/3 - Hz 0 Hz 200 Hz 00 Hz DC (x RC) (x RC) (x RC) (x RC) (x RC) Z B C G D E MECHANICAL ENDURANCE RATINGS (ON/OFF OPERATIONS) The thermal trip is not affected by the frequency of the line current. The magnetic trip is within the trip zone of the characteristic curve for frequencies from 6 2/3 to Hz. At lower and higher frequencies, the magnetic trip will be delayed longer than indicated by the characteristic curve, roughly as follows: At 0Hz: Mag. Trip Current =. x curve current At 200Hz: Mag. Trip Current =.2 x curve current At 00Hz: Mag. Trip Current =. x curve current At DC: Mag. Trip Current =.5 x curve current For example, at 6 2/3 - Hz the magnetic trip zone for the G characteristic is 8 to times the rated current of the specific V-EA (i.e., hold for at least 0ms at 8 x RC, trip in less than 0ms at x RC). With a 00Hz current, a magnetic trip at x RC would be greatly delayed (thermal would likely trip first), as the magnetic trip zone is now.2 to x RC. If a quicker magnetic trip is required with 00Hz, the B or C characteristic should be considered. Application 2 x (.5 x RC) 2 x RC RC No Load Total AC General Use AC Motor Starting Across the Line AC Incandescent Lamps (Tungsten) AC Electrical Discharge Lamps (Ballast) AC Resistance Manufacturers self certification ON/OFF operations with no load Altech UL508 Altech Corp. 35 Royal Road Flemington, NJ Phone (908) FAX (908)

14 Altech UL508 MA- Series Three Phase Adjustable Trip Miniature Circuit Breakers/ Manual Motor Controllers The MA was designed to handle the high inrush loads of 3 phase transformers, power supplies, motors, etc. The MA protects wiring and equipment from damage caused by the three major classes of over-current, yet greatly reduces the number of nuisance trips in high starting and inrush current circuits. An IEC device with excellent ratings under a UL listing at 80Y/277V (including group ratings) and at 500V under international standards, the Altech/ABL Sursum MA provides short and long term cost effective circuit protection for USA and/or export applications. The short term advantages include: () adjustable thermal trip allows finalization of initial designs before procurement of the load equipment is complete; (2) snap-on mounting for readily available, internationally standardized DIN Rail saves panel layout design time as well as installation and change labor; (3) large cage-clamp terminals with screws suitable to power screwdrivers, simplifies and speeds wiring; () convenient switched disconnect during factory testing and/or initial start-up saves time and aggravation. The key long term advantage is customer satisfaction and proven over-current protection of wiring and equipment (and the lack of rework/repair costs). Type Designation MA RT (a) (b) (c) (d) (a) = MA - Manual Motor Controller (b) = Rated Current (c) = U - US Housing (d) = Blank - Standard Terminal RT - Ring-tongue Terminal Voltage Rating AIC (Interrupt Capacity) Standard Short Circuit Withstand Rating (UL/CSA Ratings) Group Short Circuit Ratings (UL/CSA Ratings) Typical Life Calibration Temperature Standard Pack and Weight Terminal Size Acceptability UL508 listed E37938 CAN/CSA-C22.2 No. certified 80Y/277VAC 0.6A-2.5A: 2kA;.0A-6A: ka; 20A-0A: ka 0.6A-2.5A: 2kA;.0A-6A: ka see above 00 on/off operations with 2xRC 25 C, +0, -5 (77 F, +0-9 ) /50g (.0 lb.) Top/Bottom: 8-3 AWG Type and Rated Current Cat. No. FLA Dial Adjustment Markings MA0.6U 5.90U 0./ 0.2/0./0.6 MA0.25U 5.902U 0.6/0.9/0.22/0.25 MA0.0U 5.903U 0.25/0.30/0.35/0.0 MA0.63U 5.90U 0.0/0.8/0.56/0.63 MA.0U 5.905U 0.63/0.75/0.87/.0 MA.6U 5.906U.0/.2/./.6 MA2.5U 5.907U.6/.9/2.2/2.5 MA.0U 5.908U 2.5/3.0/3.5/.0 MA6.3U 5.909U.0/.8/5.6/6.3 MAU 5.9U 6.3/7.5/8.7/ MA6U 5.9U /2//6 MA20U 5.92U 6/7/8.5/20 MA25U 5.93U 20/2.5/23/25 MA32U 5.9U 25/27/30/32 MA0U 5.95U 32/3/37/0 GROUP SHORT CIRCUIT RATING AT 80VAC a (and BCP size) 2kARMS symmetrical (max. 200A MCCB or RK5) karms symmetrical (max. 350A MCCB or RK5) karms symmetrical (max. 350A MCCB or RK5) 3Ø HORSEPOWER RATINGS AT NOMINAL LINE VOLTAGE (See Note for HEA Definition) -20V HP (HEA) 200V HP (HEA) 208V HP (HEA) V HP (HEA) -80V HP (HEA) Through MA2.5U, ampere rated for motor circuits having a fullload-amperage (FLA) not exceeding the MAʼs general purpose rated current (RC, equals maximum dial setting) and a locked rotor current not exceeding 6 times the MAʼs RC. /2 (.0) 3/ (3.2) 3/ (3.) (3.6) 2 (3.2) 3/ (5.6) /2 (6.0) /2 (5.7) /2 (5.2) 3 (.8) (7.2) 2 (7.8) 2 (7.5) 3 (9.6) 5 (7.6) 2 (3.6) 3 (.0) 3 (.6) 5 (5.2) (.0) 3 (9.2) 5 (7.5) 5 (6.7) 5 (5.2) (.0) 3 (9.2) 5 (7.5) 7/2 (2.2) 7/2 (22.0) 5 (2.0) 5 (30.) 7/2 (25.0) 7/2 (2.2) (28.0) 20 (27.0) 5 (30.) (32.0) (3.0) (28.0) 25 (3.0) Note: HEA - Horsepower Equivalent Amperes, the nominal amperage assigned to standard motor horsepower ratings in design guide tables such as NFPA-70 Tables 30-28, 30-29, ; UL77 Table 6.2; CSA - C22.2 No. 235-M89 Tables and 5; CSA-C22.2 No. -M9 Table 9, etc. Multiply HEA values (in parenthesis) by. if power factor is 90%, and by.2 if power factor is 80%. a The standard-circuit short-circuit rating is ka for all types. Group ratings can be used in a standard circuit (e.g., MA.0U at 2kA), but a higher standard rating cannot be used in a group circuit (e.g., MA0U at ka only in standard circuit.) 32 Altech Corp. 35 Royal Road Flemington, NJ Phone (908) FAX (908)

15 DIMENSIONS mm (.73 in.) 37.5mm (.8 in.) mm (.0 in.) 6mm (.2 in.) 7mm (.28 in.) 0 20 MA0.6U-MA6U MA 3 Phase Controller (B, C, D) Must Trip Current = 5% of Dial Setting Must Not Trip > hr = 5% of Dial Setting 89.5mm (3.52 in.) 5mm (.77 in.) 35mm (.38 in.) 5mm (.77 in.) Magnetic Trip Nominal 0% of Rated Current 7mm (.28 in.) mm (.28 in.) L MA.6 VDE 06 AC-3 500V 50-Mz 30.5mm (.20 in.) mm (.73 in.) MA/USA Manual Motor Controller ABL SURSUM T 2 2A A 68mm (2.68 in.) L2 T2 3 A 6A L3 0 C T3 52.5mm (2.07 in.) 5 20 C 6 3mm (.2 in.) Multiple of Dial Setting (Thermal) (Magnetic Trip) Rated Current = Max. Dial Setting Altech Corp. 35 Royal Road Flemington, NJ Phone (908) FAX (908) MA20U-MA0U MA 3 Phase Controller (B, C, D) Must Trip Current = 5% of Dial Setting Must Not Trip > hr = 5% of Dial Setting Magnetic Trip Nominal 0% of Rated Current Multiple of Dial Setting (Thermal) (Magnetic Trip) Rated Current = Max. Dial Setting 33Altech UL508

16 Altech UL508 V-EA and MA Circuit Breaker Accessories UL508 listed E37938 Accessories can be factory or field mounted on V-EA and MA manual motor controllers for enhanced control and monitoring capabilities. Field mounting kits include all necessary parts and instructions. Accessories can be gang mounted on a single controller (the Auxiliary Switch in the outside position). The mounting arrangement links the internal latch-pins for the tripping mechanisms, ensuring simultaneous trips. Handles are linked to simplify manual resetting. FA - Shunt Trip Trip/Coil Type/ Voltage Max. Coil Cat. No. AC or DC Current Approvals FA2U 2V.3A FA2U 2V 0.6A FA8U 8-72V 0.2A FAU V/220V 0.25A/0.5A Std.Pk.: Unit 20 grams (0.27 lb.) Width: 7.5mm (.689in.) UA - Undervoltage Trip (not UL listed) Type/ Cat. No. Line Voltage Hz* UA20 UA20 UA277 UA5 UA80 20VAC 20VAC 277VAC 5VAC 80VAC Std.Pk.: Unit 70 grams (0.6 lb.) Width: 7.5mm (.689in.) H - Auxiliary Switch For further Busbar information please see pages or our comprehensive Altech Universal Power Distribution catalog. Type/ Contact Wire Cat. No. Rating Size Approvals For Use With: HU A / 220V AC mm 2 (2 AWG) V-EA, MA 3A / V DC or pulsed A / 220V DC or pulsed Std. Pk.: Unit 5 grams (0.2 lb.) Width: 9mm (.35in.) Lock-out ** Cat. No. EASS Cooling Spacer Cat. No. 5.9 Prevent inadvertent resetting of the V-EA or MA during maintenance. Fits / pad lock. * Please consult Altech for your 50Hz application needs. ** V-EA and MA can also be locked in the on and off position by simply using a common lead or meter seal, which gets fed through the hole in the handle and a corresponding hole in the housing. 3 Altech Corp. 35 Royal Road Flemington, NJ Phone (908) FAX (908)

17 TEMPERATURE CORRECTION CURVE Ambient Temperature and Adjacent Mounting/Loading Adjustment (V-EA/MA Ambient Temperature - 25 C to 55 C, Storage Temperature -0 C to 70 C) Rated Current (%) % Calibration Temperature Ambient Temperature Adjustment 5% of RC for every C (8 F). Adjacent Mounting Temperature Adjustment 3% of RC for every additional pole above 3. Maximum 20% off RC for a total of poles or more.* up to 3 poles adjacent mounted * Cooling spacer (Part #5.9) between each group of 3 poles will eliminate these adjustments Ambient Temperature maximum 20% off RC for a total off poles or more, adjacent mounted* ( C) 9 ( F) Altech UL508 Altech Corp. 35 Royal Road Flemington, NJ Phone (908) FAX (908)

18 Altech UL508 MS-Series Three Phase Adjustable Trip Economy Manual Motor Controllers with overload and short circuit protection, phase failure sensitivity according to IEC 97--, DIN VDE 06 Part 2 C US E37938 Type Designation MS 06 (a) (b) (a) = MS - Manual Motor Controller (b) = Rated Current With its high breaking capacity and current limitation the MS Manual Motor Controllers provide optimum protection for electrical motors as well as for other consumer units up to 25 amps. They are equipped with phase failure sensitivity, isolating and main switch functions. 3 ranges cover nominal rated currents from 0. up to 25 amps. The MSʼs are temperature compensated; the trip current of the magnetic part is 2 x ln. The Manual Motor Controllers are built in accordance with IEC 97. Type/ Rated Overload Instantaneous 3Ø Horsepower Rating Cat. No. Current release setting adjustment/fla (A) (A) 5V 200V 230V 80V 0V Ampere rated for motor circuits having MS a full-load-amperage (FLA) not MS exceeding the MSʼs general purpose MS rated current and a locked rotor MS current not exceeding 6 MS /2hp /2hp times the MSʼs rated MS /hp hp current. MS /2hp /2hp hp /2hp MS /2hp 3/hp hp 2hp 3hp MS /hp /2hp /2hp 3hp 5hp MS hp 2hp 3hp 5hp 7/2hp MS hp 3hp 5hp hp hp MS hp 5hp 7/2hp 5hp MS hp 5hp 7/2hp 5hp Maximum Voltage Interrupting Capacity (UL/CSA Rating) Group Short Circuit (UL/CSA - Ratings) Interrupting Capacity (VDE - Ratings) Mechanical Endurance Standard Pack and Weight Terminal Size Acceptability Terminal Torque 0V AC (MS20 and MS25, 80V AC) 5kA 5kA A: Self protected -25A: 6kA 000 on/off operations /250g (0.55lb) - AWG.8Nm (6lb. in.) Dimensions 5mm (.77 in.) 2mm (.65 in.) 76.5mm (3.0 in.) 80mm (3.5 in.) 5mm (.77 in.) 35.5mm (.0 in.) 30mm (.8 in.) 63mm (2.8 in.) 7.5mm (2.8 in.) 75.5mm (2.97 in.) 85.5mm (3.37 in.) 36 Altech Corp. 35 Royal Road Flemington, NJ Phone (908) FAX (908)

19 Accessories MS Three Phase Adjustable Trip Economy Auxiliary contact blocks for side mounting (3.5A/230VAC; 2A/00V AC) Manual Motor Controllers Width Contacts Type/ Weight Std. mm Cat. No. g/pc. Pk. 9 2NO HMS NO + NC HMS 0 9 NO HMS NC HMS NC HMS0 35 Insulated Enclosure IP55 with integrated PE(N) terminal; top and bottom each have 2 metric knock-outs Type/ Weight Std. Cat. No. g/pc. Pk. MS.G55 20 Emergency-Stop twist or key to release, red on yellow background Release Type/ Weight Std. Type Cat. No. g/pc. Pk. Twist MS.PV 5 Key MS.PS Flush Mounting Enclosure IP55 with integrated PE(N) terminal Indicator Light with neon bulb, nominal rated voltage: V or 380-0V Busbar Type/ Weight Std. Cat. No. g/pc. Pk. MS.F55 70 Type/Cat. No. Busbar for for for for 63A 2 MS 3 MS MS 5 MS no spacing G5--2 G5--3 G5-- G5--5 with auxiliary switch (/2 pole) G5--2 G5--3 G5-- G5--5 spacing Color Type/ Weight Std. Cat. No. g/pc. Pk V 380-0V trans MS.SLW2 MS.SLW3 5 green MS.SLG2 MS.SLG3 5 red MS.SLR2 MS.SLR3 5 yellow MS.SLJ2 MS.SLJ3 5 Power Feed Block Type/ Rating Std. Cat. No. (A) Pk. GE2-63A Altech Corp. 35 Royal Road Flemington, NJ Phone (908) FAX (908) Altech UL508

E s h o r t c ir c u it Wit h s t AND r At ing s f o r r -s er ies s u ppl ement Ar y pr o t ec t o r

E s h o r t c ir c u it Wit h s t AND r At ing s f o r r -s er ies s u ppl ement Ar y pr o t ec t o r UR-Series UL077 Recognized Supplementary Protector DIN Rail Mounted 7.5mm width per pole Thermal Magnetic 80Y/277V AC, 50/Hz 0kA Short Circuit Withstand Capacity Applications (on the load side of Branch

More information

Typical UL1077 Application

Typical UL1077 Application Altech UL77 Typical UL77 Application Control Circuit of a UL508A Panel Disclaimer: This is just an example application. Installation should be done by a qualified electrician under the guidance of UL/NEC

More information

Control Circuit of a UL508A Panel. Typical UL1077 Application

Control Circuit of a UL508A Panel. Typical UL1077 Application Altech UL077 Typical UL077 Application Control Circuit of a UL508A Panel Disclaimer: This is an example application. Installation should be done by a qualified electrician under the guidance of UL/NEC

More information

Quality Commitment UL 489 UL 508 UL Equipment Breakers. Earth Leakage. Circuit Breakers

Quality Commitment UL 489 UL 508 UL Equipment Breakers. Earth Leakage. Circuit Breakers UL 89 ANNEX Since 98, Altech Corporation has grown to become a leading supplier of automation and industrial control components. Headquartered in Flemington, NJ, Altech has an experienced staff of engineering,

More information

Typical UL489 Application Power Circuit of a UL508A Panel

Typical UL489 Application Power Circuit of a UL508A Panel Altech UL489 Typical UL489 Application Power Circuit of a UL508A Panel Disclaimer: This is an application example. Installation should be done by a qualified electrician under the guidance of UL specifications..

More information

S200 UL 489 Series. Miniature circuit breakers S200. Features. Description

S200 UL 489 Series. Miniature circuit breakers S200. Features. Description UL 489 Series UL 489 Series Description The Series miniature circuit breaker offers a compact solution for protection requirements. The U AND UP devices are UL 489 tested limiting and DIN rail mounted.

More information

Miniature Circuit Breakers

Miniature Circuit Breakers S00 Series Miniature S00 Series Miniature Circuit Breakers Description The S00 Series miniature circuit breaker offers a compact solution for protection requirements. The S00 devices are UL tested limiting

More information

UMBW-UL489 and UL1077 Listed

UMBW-UL489 and UL1077 Listed -UL489 and UL77 Listed Introducing the New WEG Series Thermal-Magnetic Miniature Breakers. This new offering includes both UL489 and UL77 approvals to provide a solution for circuit & equipment protection

More information

Protection Equipment. 5/2 Introduction

Protection Equipment. 5/2 Introduction Protection Equipment /2 Introduction SIRIUS 3RV2 Motor Starter Protectors/ Circuit Breakers up to 40 A /6 General data /12 For motor protection /14 For motor protection with overload relay function /1

More information

Control Circuit Protection

Control Circuit Protection Contents 5SJ4 Branch Circuit Protectors 5SY4 Supplementary Protectors 5SY6 Supplementary Protectors 16/19 5SJ4 Page Selection and ordering data 1-pole up to 63A 16/4 1-pole, 2-pole, 16/5 3-pole, 240VAC

More information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information

KT4 Manual Motor Starter

KT4 Manual Motor Starter KT4 Manual Motor Starter Ideal for use as a manual starter The KT4 is a manual motor starter that employs the features of power switching, thermal overload protection and control circuit signaling in one

More information

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories Manual motor protectors Manual motor protectors Manual motor Protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certified

More information

Product index. 4 - Manual motor protectors. Phone: Fax: Web: -

Product index. 4 - Manual motor protectors. Phone: Fax: Web:  - Product index -....1.3 Features and benefits...1 General information Suitable applications...2 -.3 Motor ratings... Pilot duty ratings and overload trip classes...5 Ordering details Type MS116...6 Type

More information

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL ed and

More information

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers Series KTU7 UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s KTU7 series of UL Molded Case Circuit Breakers are UL489 and CE listed

More information

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00, Low-Voltage Controls and Distribution > Industrial Controls > Protection Equipment > Circuit Breakers/Motor Starter Protectors > Motor Starter Protectors SIRIUS RV up to 00 A RV0-0DA5 CIRCUIT-BREAKER,

More information

Selection Guide. Control Circuit and Load Protection

Selection Guide. Control Circuit and Load Protection Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature

More information

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certifi ed for

More information

F-Series. Circuit Breaker

F-Series. Circuit Breaker F-Series Circuit Breaker The F-Series hydraulic/magnetic high amperage circuit breakers are designed to handle high current applications in extremely hot and/or cold locations. Due to its timeproven hydraulic/magnetic

More information

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4. Product index -....1.3 Features and benefits...1 General information Suitable applications...2 -.3 Motor ratings... Pilot duty ratings and overload trip classes...5 Ordering details Type MS116...6 Type

More information

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

The breakers offer thermal-magnetic trip protection according to Z and K characteristics. Series High Performance Circuit Breakers Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific

More information

F-Series. Circuit Breaker

F-Series. Circuit Breaker F-Series Circuit Breaker The F-Series hydraulic/magnetic high amperage circuit breakers are designed to handle high current applications in extremely hot and/or cold locations. Due to its timeproven hydraulic/magnetic

More information

Bulletin 1489 Circuit Breakers. Selection Guide

Bulletin 1489 Circuit Breakers. Selection Guide Bulletin 1489 s Selection Guide Bulletin 1489-A Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable

More information

Protection Equipment

Protection Equipment Protection Equipment Price Groups 101, 102, 121, 131, 143 /2 Introduction Motor Starter Protectors/ Circuit Breakers SIRIUS 3RV2 Motor Starter Protectors up to 40 A new /7 General data /13 For motor protection

More information

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400 Page -2 Page -4 Page -6 FOR BG SERIES MINI-CONTACTORS Type RF9, phase failure sensitive, manual resetting Type RFA9, phase failure sensitive, automatic resetting Type RFN9, non-phase failure sensitive,

More information

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers Series UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s series of UL are UL489 and CE listed for global applications. The current

More information

S200 UL 1077 Series S200. Supplementary protective devices. UL 1077 Series. Miniature. circuit breakers. S200 Supplementary protective devices

S200 UL 1077 Series S200. Supplementary protective devices. UL 1077 Series. Miniature. circuit breakers. S200 Supplementary protective devices UL 077 Series Supplementary protective devices The UL 077 Series miniature supplementary protector offers a compact solution for protection requirements. The devices are DIN rail mounted. The is available

More information

S200 UL 489 Series. Miniature Circuit Breakers. Description. Features

S200 UL 489 Series. Miniature Circuit Breakers. Description. Features S200 UL 489 Series Miniature S200 UL 489 Series Miniature Circuit Breakers Description The S200 Series miniature circuit breaker offers a compact solution for protection requirements. The S200U AND S200UP

More information

Ideal for use as a manual starter

Ideal for use as a manual starter Manual Motor Starter Ideal for use as a manual starter The is a manual motor starter that employs the features of power switching, thermal overload protection and control circuit signaling in one compact

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

A302DN.40/.63A Thermal Current Motor Starter

A302DN.40/.63A Thermal Current Motor Starter 4 South Street 7964-76, TX Nacogdoches Phone: 96-69-794 Fax: 96-60-468 A0DN.40/.6A Thermal Current Motor Starter Eaton Corp A0DN Manufacturer Eaton Corp Description Manual Motor Starter, Motor Protector;

More information

G-Series. Circuit Breaker.

G-Series. Circuit Breaker. -Series Circuit Breaker Carling Technologies -Series hydraulic/magnetic circuit breakers offer the highest quality solution to your circuit protection requirements. The -Series is designed to sense over-current

More information

209 Series. Magnetic Circuit Protectors

209 Series. Magnetic Circuit Protectors 29 Series Magnetic Circuit Protectors Introduction 249 Power Selector System Multi-Pole Configurations Operating Characteristics Delay Curves Specifications Decision Tables 73 75 77 79 8 82 85 87 29/29/229/249/279

More information

Essential equipment for all your requirements

Essential equipment for all your requirements NEW CTX CONTACTORS Essential equipment for all your requirements 9 A TO 310 A THREE-POLE INDUSTRIAL CONTACTORS CTX three-pole industrial contactors, a sense of family The new range of CTX contactors provides

More information

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories Page 1 of 5 MS132-10 ABB contact for United States of America General Information Extended Product Type: Product ID: EAN: Catalog Description: Long Description: MS132-10 1SAM350000R1010 4013614400100 MS132-10

More information

Selection Guide Motor Control Device Solutions

Selection Guide Motor Control Device Solutions Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements

More information

Features 1 Phase HP/Volts 1/6 HP AT 230 V 3 Phase HP/Volts 1/2 HP AT 200/230 V, 1-1/2 HP AT 460/575 V

Features 1 Phase HP/Volts 1/6 HP AT 230 V 3 Phase HP/Volts 1/2 HP AT 200/230 V, 1-1/2 HP AT 460/575 V 804 South Street 7964-76, TX Nacogdoches Phone: 96-69-794 Fax: 96-60-468 A07NN A Man Motor Protector Eaton Corp Catalog Number A07NN Manufacturer Eaton Corp Description Manual Motor Starter, Motor Protector;

More information

Altech UL1077/508 Busbar System

Altech UL1077/508 Busbar System Altech UL1077/508 Busbar System UL1077/508 Listed Busbars The Altech Busbar System is an innovative way to jumper up to 57 poles of Manual Motor Controllers (MMC) and Supplementary Protectors (SP). The

More information

1492-CB 1492-GH 1492-GS

1492-CB 1492-GH 1492-GS 1 The Allen-Bradley Line of Devices Allen-Bradley offers 3 different lines of Circuit Breakers (Supplementary Protectors) and a line of branch circuit rated Fuse Holders. Allen-Bradley Thermal Magnetic

More information

PD-Series Ground Fault Circuit Protection

PD-Series Ground Fault Circuit Protection PD-Series Ground Fault Circuit Protection SmartGuard is an equipment ground fault protection device that functions as a standard high-quality Carling hydraulic/ magnetic circuit breaker, offering customized

More information

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866) .4 Miniature Circuit Breakers and Supplementary Protectors SPHM Supplementary Protector SPHM Supplementary Protector Product Description The SPHM Supplementary Protector is a dual rated product for both

More information

Technical data for manual motor starters Type MS325

Technical data for manual motor starters Type MS325 for manual mor starters Type MS325 General data Rated voltage 600 V Rated current 25 A (14 setting ranges, 0.1 25A) Rated frequency 50-60 Hz Electrical and mechanical life endurance 100,000 operations

More information

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control . Contents Description Relays and Timers......................... Miniature Controls......................... Contactors and Starters.................... Thermal Relays.................... C440/XT Electronic

More information

Jtec 10kA Miniature Circuit Breaker

Jtec 10kA Miniature Circuit Breaker EN 60898 Jtec 10kA Miniature Circuit Breaker Techna s JTEC range has been enthusiastically adopted by a diverse range of customers seeking a cost effective 10kA performance. Jtec MCBs are available in

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

1489-M Circuit Breakers

1489-M Circuit Breakers Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Terminal design helps prevent wiring misses Scratch- and solventresistant printing Suitable

More information

XT IEC Power Control Manual Motor Protectors

XT IEC Power Control Manual Motor Protectors May 07 Product Selection Table 7. Rotary with Screw Terminals Global Ratings and North American Ratings Type and Type 2 Coordination Motor Protective Device with Thermal and Magnetic Trip Rated Uninterrupted

More information

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction Introduction Introduction Schneider Electric offers a complete line of products for the manual control and protection of motors. This catalog covers those devices designed to meet IEC standards for protection

More information

AP/UP, AP/MIL Series Magnetic Circuit Protectors

AP/UP, AP/MIL Series Magnetic Circuit Protectors AP/UP, AP/MIL AP/UP, AP/MIL Series Magnetic Circuit Protectors Introduction 68 Single Pole 69 Multi-Pole 70 Configurations 72 Operating Characteristics 73 Delay Curves 74 Specifications 75 Decision Tables

More information

Series L9 UL-489 Miniature Circuit Breakers

Series L9 UL-489 Miniature Circuit Breakers Series UL-489 iniature Breakers Industrial Breakers for Branch up to 40 Amps Sprecher+Schuh includes a line of circuit breakers approved for branch circuit applications in the United States and Canada

More information

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E Issued to: SIEMENS AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG, GERMANY This is to certify that representative samples of Motor Controllers, Magnetic USL, CNL - Type No 3RT10, 3RT11,

More information

Technical Information

Technical Information -100 Controller IEC Performance Data (CSA C22.2, UL 508 No. 14 in connection with a short-circuit protection device Catalog No. -100... 25A 40A 63A 90A Maximum Short-Circuit Current 480V [ka] 65 65 42

More information

OTEC Transfer switch open transition

OTEC Transfer switch open transition Specification sheet OTEC Transfer switch open transition 40 1200 amp Description OTEC transfer switches are designed for operation and switching of electrical loads between primary power and Standby generator

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker -F... Description An extremely versatile range of rocker switch/thermal circuit breakers (S-type TO CBE to EN 694 with trip free mechanism) offering the choice of single

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker 20-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (Stype TO CBE to EN 6094 with trip free mechanism) offering the choice of

More information

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI . Technical Data and Specifications Ratings Frames EG, JG and LG EG JG LG Maximum rated current (amperes) 15, 160 1 50 400, 630 Breaker type 3 B B E S S H H C E S H C U X E S H C U X of poles 1, 3, 4,

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (S-type TO CBE to EN 6094 with trip free mechanism) offering the choice of single pole, double pole with single pole protection,

More information

Single Pole Circuit Protectors 55. Multi-Pole Circuit Protectors 56. Configurations 58. Operating Characteristics 59.

Single Pole Circuit Protectors 55. Multi-Pole Circuit Protectors 56. Configurations 58. Operating Characteristics 59. Single Pole Circuit Protectors 55 Multi-Pole Circuit Protectors 56 Configurations 58 Operating Characteristics 59 Delay Curves 60 Specifications 61 Decision Tables 62 SINGLE POLE CIRCUIT PROTECTORS The

More information

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Thermal-magnetic Miniature Circuit Breaker 4230-T... Thermal-magnetic Miniature Circuit Breaker 420-T... Description Single pole and multipole thermal-magnetic miniature circuit breakers (MCBs) in accordance with EN 60947-2, UL 077 and UL 489 for DIN rail

More information

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS MANUFACTURED IN THE EU EUROPEAN QUALITY 1, 2 & 3 POLE MCB s TRIPPING CURVES C & D CURRENT RATINGS 1AMP TO 63AMPS 10KA BREAKING CAPACITY

More information

DPX moulded case circuit breakers

DPX moulded case circuit breakers BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.

More information

MS General Information Extended Product Type: MS

MS General Information Extended Product Type: MS MS132-1.6 General Information Extended Product Type: MS132-1.6 Product ID: 1SAM350000R1006 EAN: 4013614400063 Catalog Description: MS132-1.6 Manual Motor Starter Long Description: The MS132-1.6 manual

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker 0-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (S-type TO CBE to EN 6094 with trip free mechanism) offering the choice of

More information

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5 3-pole DC Operated Ratings Rated Aux. Contacts Type Coil voltage 1) AC2 Current Built-in Additional 24 24V= DC 5 AC3 see 48 60V= DC 6 380V AC1 page 34 110 110V= DC 7 400V 660V 220 220V= DC 8 415V 690V

More information

Series L9 UL489 Miniature Circuit Breakers

Series L9 UL489 Miniature Circuit Breakers Series L9 UL489 iniature Circuit Breakers Industrial Circuit Breakers for Branch Circuit Protection up to 63 Amps L9 Series B Circuit Breakers Series B L9 UL489 circuit breakers offer new features, expanded

More information

BETA Switching Switches and Light Indicators

BETA Switching Switches and Light Indicators Siemens AG 2008 BETA Switching /2 Product overview /3 5TE8 control switches / 5TE4 pushbuttons /2 5TE5 light indicators /5 5TE8 ON/OFF switches /22 5TE9 busbars /24 5TE switch disconnectors Siemens ET

More information

3. Coils shall be of molded construction

3. Coils shall be of molded construction .7-4 Motor Starters & Contactors Low Voltage Enclosures General Non-Combination Starters January 00 Sheet 8 0 7 8 9 4 Non-Combination Starters Maximum hp, Volts Typical Non-Combination Starter Application

More information

209/219/229/249/279 Series Magnetic Circuit Protectors

209/219/229/249/279 Series Magnetic Circuit Protectors 29/29/229/249/279 29/29/229/249/279 Series Magnetic Circuit Protectors Introduction 65 249 Power Selector System 67 Multi-Pole 69 Configurations 7 Operating Characteristics 73 Delay Curves 74 Specifications

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker 20-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (Stype TO CBE to EN 6094 with trip free mechanism) offering the choice of

More information

Motor Controllers + Circuit Breakers

Motor Controllers + Circuit Breakers Series General...2 Series & KTA3-100 Base Units...4 Series Base Units...6 Series Base Units...8 Accessories...10 Technical Information -...20 Dimensions -...33 Technical Information - KTA3-100...39 Dimensions

More information

SD Series Non-Fused Load Switches

SD Series Non-Fused Load Switches SD Series Non-Fused Load Switches The SD1 and SD2 series of non-fused load switches are listed as Manual Motor Controllers and are designed for use in local motor isolation. The SD series of modular load

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker 20-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (S-type TO CBE to EN 6094 with trip free mechanism) offering the choice of

More information

IEC Power Control SIRIUS. Motor Starter Protectors. Revised 04/20/15. Section Overview... 1/2-1/3. Motor Starter Protectors

IEC Power Control SIRIUS. Motor Starter Protectors. Revised 04/20/15. Section Overview... 1/2-1/3. Motor Starter Protectors 04/20/15 IEC Power Control Motor Starter Protectors Contents Pages Section Overview......................... 1/2-1/3 Motor Starter Protectors 3RV20 MSP, Class 10/20.................... 1/4-1/5 3RV10 MSP,

More information

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker 20-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (Stype TO CBE to EN 6094 with trip free mechanism) offering the choice of

More information

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931 Data Bulletin 0931DB0101 July 2001 Cedar Rapids, IA, USA Ground-Censor Ground-Fault Protection System Type GC Class 931 09313063 GT Sensor Shunt Trip of Circuit Interrupter Window Area for Conductors GC

More information

Thermal-Magnetic Circuit Breaker 201/-WA

Thermal-Magnetic Circuit Breaker 201/-WA Thermal-Magnetic Circuit Breaker 0/-WA Description Single pole thermal-magnetic circuit breaker with tease-free, trip-free, snap action mechanism and two button operation (M-type TM CBE to EN 60934). Featuring

More information

4 - Miniature controls

4 - Miniature controls Index -....1.22 Selection Contactors for connection to PLCs, B6S & B7S, 3 phase...6 Contactors, Interface, B6 & B7, 3 phase...5 Contactors, features...1 Contactors, mechanically interlocked, B6 & B7, 3

More information

PB-Series. GFCI/ELCI & Panel Seal

PB-Series. GFCI/ELCI & Panel Seal PB-Series GFCI/ELCI & Panel Seal The PB-Series utilizes the hydraulic magnetic principle which provides precise operation and performance even when exposed to extremely hot and/or cold application environments.

More information

F Motor Circuit Controllers. Series KT7 Motor Circuit Controllers. KT4 Manual Motor Starters. General Description...F2

F Motor Circuit Controllers. Series KT7 Motor Circuit Controllers. KT4 Manual Motor Starters. General Description...F2 Series KT7 General...2 Series & KTA3-100 Base Units...4 Series Base Units...6 Series Base Units...8 Accessories...10 Technical Information - KT7...20 Dimensions - KT7...32 Technical Information - KTA3-100...37

More information

Siemens AG Price groups PG 14O, 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J

Siemens AG Price groups PG 14O, 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J Protection Equipment Siemens AG 2015 Click on the Article No. in the catalog PDF to access it in the Industry Mall and get all related information. Article-No. 3RA1943-2C 3RA1943-2B 3RA1953-2B 3RA1953-2N

More information

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077 Data Sheet System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077 2CDC021026S0011 2CDC021016S0012 The S 200 PR is a high-performance supplementary protector with

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance (012730_C_000) Issued to: Siemens AG DF CP R&D VC 2 WernervonSiemensStrasse 48 Amberg, 92224 GERMANY The products listed below are eligible to bear the CSA Mark shown Issued by:

More information

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489 MINIATURE CIRCUIT BREAKERS SU200M Datasheet Branch protection acc. to CSA C22.2 No.5 / UL 489 The miniature circuit breaker SU200 M is ABB s solution for UL 489 branch circuit protection up to 480 Y/277

More information

Motor Starter Protectors

Motor Starter Protectors Motor Starter Protectors Industrial Controls Product Catalog 207 Section contents Section Overview /2 - /3 Motor Starter Protectors 3RV20 MSP, Class 0/20 /4 - /5 Circuit Breakers 3RV27, 3RV28 Circuit Breaker

More information

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control Contents Description Relays and Timers......................... Miniature Controls......................... Contactors and Starters.................... Thermal Overload Relays.................... C440/XT

More information

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD. DATASHEET - DILMC9-10(24VDC) Technical data General Contactor, 3p+1N/O, 4kW/400V/AC3 Part no. DILMC9-10(24VDC) Catalog No. 277468 Eaton Catalog No. XTCEC009B10TD EL-Nummer 4110305 (Norway) Standards IEC/EN

More information

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1 Motor Contactor J7KN Range from 4 to 500 kw (AC 3, 380/415 V) AC and DC operated Integrated auxiliary contacts; integrated aux. contact of J7KN contactors up to 11kW suitable for electronic circuits Screw

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Thermal-magnetic Miniature Circuit Breaker 4230-T... Thermal-magnetic Miniature Circuit Breaker 40-T... Description Single pole and multipole thermal-magnetic miniature circuit breakers (MCBs) in accordance with EN 60947-, UL 1077 and UL 489 for DIN rail

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker 0-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (S-type TO CBE to EN 6094 with trip free mechanism) offering the choice of

More information

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489 System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU 200 M is ABB s solution for UL 489 branch

More information

Motor Starter Protectors

Motor Starter Protectors Motor Starter Protectors Industrial Controls Product Catalog 09 Section contents Section Overview / - /3 Motor Starter Protectors 3RV0 MSP, Class 0/0 /4 - / Circuit Breakers 3RV7, 3RV8 Circuit Breaker

More information

Electronic Circuit Breaker ESS20-0..

Electronic Circuit Breaker ESS20-0.. Electronic Circuit Breaker ES-0.. Description Electronic circuit breaker type ES-0.. is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 4 V switch-mode

More information

FMotor Circuit Controllers

FMotor Circuit Controllers Technical Information Motor Circuit Controller IEC Performance Data Catalog Number KTA7-25S...32S 0.16A 0.25A 0.4A 0.63A 1A 1.6A 2.5A 4A 6.3A 10A 16A 20A 25A 29A 32A Rated Operational Current, I e [A]

More information

Thermal Circuit Breaker 3120-F...

Thermal Circuit Breaker 3120-F... Description The 320 circuit breaker/switch combination is an ON/OFF switch with integral overcurrent protection (S-type TO CBE to EN/IEC 60934). The trip element is a bimetal. Type 320 is ideally suited

More information

NRA Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

NRA Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute RA Series RA Series Key features of the RA series include: Available in 5 different styles Excellent overload and short circuit protection Small size and high-efficiency Life expectancy of over 0,000 operations

More information

Thermal-Magnetic Circuit Breaker M1-...

Thermal-Magnetic Circuit Breaker M1-... Thermal-Magnetic Circuit Breaker 320-...-M-... Description Two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 6034). The addition of a magnetic tripping

More information