Thermal Overcurrent Circuit Breaker 3120-F...

Size: px
Start display at page:

Download "Thermal Overcurrent Circuit Breaker 3120-F..."

Transcription

1 Thermal Overcurrent Circuit Breaker 20-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (Stype TO CBE to EN 6094 with trip free mechanism) offering the choice of single pole, double pole with single pole protection, and double pole with protection on both poles. Designed for snap-in panel mounting with versions available for three different panel cut-out sizes. Illumination is optional and there is a range of colours and markings for the rocker. Under over conditions the rocker returns to the OFF position. 6-way frame for 20-F5 available upon request. Any one of the following additional function modules can be supplied factory fitted to the rear of the switch/circuit breaker. Under voltage release coil (for double pole versions only). Magnetic trip coil for short circuit protection. Magnetic trip coil for remote relay trip. Auxiliary contacts for status signalling. Mechanical slide interlock. Approved to CBE standard EN 6094 (IEC 6094). 20-F... Typical applications Motors, transformers, solenoids, extra low voltage wiring systems, office machines, electro-medical equipment, power supplies, communications systems, medical equipment to EN Standard current ratings and typical internal resistance values Current Internal Current Internal rating (A) resistance rating (A) resistance per pole per pole (Ω) < < < < < < 0.02 Approvals Authority Voltage ratings Current ratings VDE, Semko AC 240 V, DC 28 V A (EN 6094) DC 50 V A 2pole DC 50 V A pole BV, LRoS AC 0 V, DC 28 V A UL, CSA AC 0 V, DC 50 V A Illumination voltage/power consumption operating voltage power consumption filament/neon LED 6 V 60 ma 9 ma 2 V 20 ma 9 ma 24 V 20 ma 9 ma 48 V 20 ma.5 ma 5 V < ma < ma* 20 V < ma < ma* 45 V < ma not available * single pole version only Technical data Voltage rating Current ratings Typical life AC 240 V; DC 50 V (AC 45 V to special order) (UL: AC 0 V; DC 50 V) A (up to 0 A to special order, single pole only) 50,000 operations for I N 6A double pole 0,000 operations for I N 6A single pole, 0,000 operations for I N >6 A Ambient temperature C ( F) Insulation co-ordination rated impulse pollution (IEC and A withstand voltage degree 2.5 kv 2 reinforced insulation in operating area Dielectric strength (IEC and 60664A) test voltage operating area AC,000 V between poles (2 pole) AC,500 V Insulation resistance >00 MΩ (DC 500 V) Interrupting capacity I cn A 0 x I N A 0 A or 50 A pole Interrupting capacity I N U N 2 pole (UL 077) A AC 0 V 200 A A AC 0 V,000 A A AC 0 V 2,000 A A AC 0 V,500 A A AC 0 V 5,000 A A DC 50 V,000 A Degree of protection operating area IP40 (IEC 60529/DIN 40050) (IP54 with water splash protection) terminal area IP00 Vibration 8 g ( Hz), ±0.6 mm (0-57 Hz) to IEC , test Fc 0 frequency cycles/axis Shock 0 g ( ms) to IEC , test Ea Corrosion 96 hours at 5 % salt mist, to IEC , test Ka Humidity 240 hours at 95 % RH, to IEC , test Ca Mass approx. g (double pole) approx. 27 g (single pole) Issue G Germany (0 9 87) USA (847) UK (0296)

2 Thermal Overcurrent Circuit Breaker 20-F... Ordering information Type No. 20 rocker switch/circuit breaker Mounting F snap in frame Size of frame panel thickness to fit mounting cut-out 50.5x2.5 mm -6.5 mm ( in) 5 to fit mounting cut-out 44.5x 22 mm -4 mm ( in) 6 to fit mounting cut-out 45x.7 mm mm ( in) Number of poles 0 unprotected, switch only pole, thermally protected 2 thermally protected 5 thermally protected on one pole only (terminals,2k,2i) 6 pole, unprotected, switch only Mounting frame design collar height mm collar height 9 mm 4 collar height 2 mm with water splash protection (IP 54), not with -F6... Terminal configuration P7 blade terminals 2x2.8x0.8 mm (QC 2x.0) (terminals 2(k), 22(k),, 2), not for under voltage module, not for switch) H7 2(k), 22(k): blade terminals 2x (QC 2x.0), 2: terminal screws, not for switch N7 as P7, but including shunt terminals 2(i) and 22 (i) as blade terminals 2x2.8x0.8 mm(qc 2x.0) not for under voltage module G7 as H7, but including shunt terminals 2(i) and 22 (i) as blade terminals 2x2.8x0.8 mm(qc 2x.0) Characteristic curve T thermal,.0-.4 x I N Q switch only Actuator style W rocker U momentary switch Switch colour designation opaque translucent (for illuminated versions) 0 black 2 white 02 white 4 red 04 red 5 orange 9 green Rocker markings A B 0 AUS OFF C D E I EIN ON 0 AUS OFF F X I EIN ON X = without marking A B C D E F X Rocker illumination (optional) B filament 48V AC/DC; neon 5V AC G green LED, AC/DC Y yellow LED, AC/DC R red LED, AC/DC Illumination voltage range V (B,G,Y,R) 0-4 V (B,G,Y,R) V (B,G,Y,R) V (B) V (B) V (B,Y,R) Current ratings A 20 - F 2 - N7 T - W 4 A B 4-0 A ordering example 20 - F N7 Q -W A (switch only) N.B. Switch only versions must be specified with -N7 or -G7 terminals. Terminals 2(k) and 22(k) are not fitted. Typical time/current characteristics single or double pole 0. 2 A 0000 Trip time in seconds Trip time in seconds A times rated current times rated current +60 C +40 F +2 C +7.4 F -0 C -22 F +60 C +40 F +2 C +7.4 F -0 C -22 F The time/current characteristic curve depends on the ambient temperature prevailing. In order to eliminate nuisance tripping, please multiply the circuit breaker current ratings by the derating factor shown below. See also section 9 Technical information. Ambient temperature F C Derating factor Germany (0 9 87) USA (847) UK (0296) Issue G

3 Thermal Overcurrent Circuit Breaker 20-F... Internal connection diagrams Mounting style variants thermally protected on both poles 2 2(i) 2(k) pole, thermally protected 2(i) 2(k) 22(k) thermally protected on one pole only 2 2(i) 2(k) 2(i) unprotected 2 Style F. collar height 9 mm (.54 in.) (QC 2x.0) flat head screw M.5x5-MS ISO (i) 2(k) Dimensions Style F. collar height mm/.09 in Actuating force max. 5 N optional illumination in ON position OFF position Style F.4 collar height 2 mm (.079 in.), with water splash protection (i) 2(k) (i) 2(k) (QC 2x.0) flat head screw M.5x5-MS ISO (QC 2x.0) flat head screw ISO580 M.5x5-MS Style F Optional illumination Installation drawing When installing the circuit breaker apply pressure on bezel only operating area (QC 2x.0) flat head screw M.5x5-MS ISO580 2(i) 2(k) Dimension diagram for style F6 is available on request. 0 2(i) 2(k) mounting area Issue G Germany (0 9 87) USA (847) UK (0296)

4 Thermal Overcurrent Circuit Breaker 20-F... Accessories Insulated cover Y Rear terminal shroud black (IP64) Y Terminal adapter Y R blade terminal DIN C-Ms-S (QC 2x.0) ø8.5 Water splash cover, transparent (IP66) for style -F5.. X Spacer for 20-F... Y / ø ø Spacer for 20-F5... Y * * Y suitable for panel thickness < 2 mm (.079 in) * Y suitable for panel thickness < 4 mm (.57 in) Blanking piece in -F frame Y without bends sharp-edged way frame for 20-F5... upon request Cut-out dimensions Cut-out for mounting style -F with rocker and push button min. 2.5 min.098 max. R2 max max. R0. max.02 Cut-out for mounting style -F6 with rocker min. 2 min panel thickness max. R.5 max.059 A max. R0. max matt finish Cut-out for mounting style -F5 with rocker min. 2 min mm in. max. R0. max.02 max. R.5 max panel thickness dimension A mm , mm Edges of working parts: DIN All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved.product markings may not be exactly as the ordering codes. Errors and omissions excepted. 74 Germany (0 9 87) USA (847) UK (0296) Issue G

5 Thermal Overcurrent Circuit Breaker 20-F7.. Description E-T-A s proven type 20 in a new attractive styling (S-type TO CBE to EN 6094 with trip free mechanism) offering the choice of single pole, double pole with single pole protection, and double pole with protection on both poles. Designed for snap-in panel mounting with illumination as an option. Under over conditions the rocker returns to the OFF position. Any one of the following additional function modules can be supplied factory fitted to the rear of the switch/circuit breaker. Under voltage release coil (for double pole versions only). Magnetic trip coil for short circuit protection. Magnetic trip coil for remote relay trip. Auxiliary contacts for status signalling. Mechanical slide interlock. Approved to CBE standard EN 6094 (IEC 6094). Available accessories: water splash protection and actuator guard to prevent inadvertent operation. NEW 20-F7.. Typical applications Technical data Motors, transformers, solenoids, extra low voltage wiring systems, office machines, electro-medical equipment, power supplies, communications systems, boating. Standard current ratings and typical internal resistance values Current Internal resistance Current Internal resistance rating (A) per pole (Ω) rating (A) per pole (Ω) < < < < < < 0.02 Approvals Authority Voltage ratings Current ratings VDE, Semko AC 240 V, DC 28 V A (EN 6094) DC 50 V A 2-polig DC 50 V A -polig BV, LRoS AC 0 V, DC 28 V A UL, CSA AC 0 V, DC 50 V A Illumination voltage/power consumption operating voltage power consumption filament/neon LED 6 V 60 ma 9 ma 2 V 20 ma 9 ma 24 V 20 ma 9 ma 48 V 20 ma.5 ma 5 V < ma < ma* 20 V < ma < ma* 45 V < ma not available * single pole version only Voltage rating Current ratings Typical life AC 240 V; DC 50 V (AC 45 V to special order) (UL: AC 0 V; DC 50 V) A (up to 0 A to special order, single pole only) 50,000 operations for I N 6A double pole 0,000 operations for I N 6A single pole, 0,000 operations for I N >6 A Ambient temperature C ( F) Insulation co-ordination rated impulse pollution (IEC and A withstand voltage degree 2.5 kv 2 reinforced insulation in operating area Dielectric strength (IEC and 60664A) test voltage operating area AC,000 V between poles (2 pole) AC,500 V Insulation resistance >00 MΩ (DC 500 V) Interrupting capacity I cn A 0 x I N A 0 A or 50 A pole Interrupting capacity I N U N 2 pole (UL 077) A AC 0 V 200 A A AC 0 V,000 A A AC 0 V 2,000 A A AC 0 V,500 A A AC 0 V 5,000 A A DC 50 V,000 A Degree of protection operating area IP40 (IEC 60529/DIN 40050) (IP54 with water splash protection) terminal area IP00 Vibration 8 g ( Hz), ±0.6 mm (0-57 Hz) to IEC , test Fc 0 frequency cycles/axis Shock 0 g ( ms) to IEC , test Ea Corrosion 96 hours at 5 % salt mist, to IEC , test Ka Humidity 240 hours at 95 % RH, to IEC , test Ca Mass approx. g (double pole) approx. 27 g (single pole) Issue G Germany (0 9 87) USA (847) UK (0296)

6 Thermal Overcurrent Circuit Breaker 20-F7.. Ordering information Typical time/current characteristics Type No. 20 rocker switch/circuit breaker Mounting F snap in frame Size of frame panel thickness 7 to fit mounting cut-out 44.5x22mm(.75x.866 in) -4 mm( in) Number of poles 0 unprotected, switch only pole, thermally protected 2 thermally protected 5 thermally protected on one pole only (terminals,2k,2i) 6 pole, unprotected, switch only Mounting frame design N grey frame P snap-on actuator guard Q snap-on water splash cover Terminal configuration P7 blade terminals 2x2.8x0.8 mm (QC 2x.0) (terminals 2(k), 22(k),, 2), not for under voltage module, not for switch H7 2(k), 22(k): blade terminals 2x (QC 2x.0), 2: terminal screws, not for switch N7 as P7, but including shunt terminals 2(i) and 22 (i) as blade terminals 2x2.8x0.8 mm(qc 2x.0) not for under voltage module G7 as H7, but including shunt terminals 2(i) and 22 (i) as blade terminals 2x2.8x0.8 mm(qc 2x.0) Characteristic curve T thermal,.0-.4 x I N Q switch only Actuator style A rocker Switch colour designation 20 blue opaque 0 blue translucent Rocker markings single or double pole 0. 2 A 0000 Trip time in seconds A times rated current +60 C +40 F +2 C +7.4 F -0 C -22 F +60 C +40 F +2 C +7.4 F -0 C -22 F Q I 0 Q "I" and "0" moulded in Push button illumination (optional) B filament, AC/DC Illumination voltage range (optional) V 0-4 V V V V V Current ratings A Trip time in seconds times rated current 20 - F 7 2 N - N7 T - A 20 Q B 4-0 A ordering example 20 - F. 0 N - N7 Q -A 20 Q B 4-20 A (switch only) N.B. Switch only versions must be specified with -N7 or -G7 terminals. Terminals 2(k) and 22(k) are not fitted. The time/current characteristic curve depends on the ambient temperature prevailing. In order to eliminate nuisance tripping, please multiply the circuit breaker current ratings by the derating factor shown below. See also section 9 Technical information. Ambient temperature F C Derating factor Germany (0 9 87) USA (847) UK (0296) Issue G

7 Thermal Overcurrent Circuit Breaker 20-F7.. Dimensions Internal connection diagrams Style -F7.N ±0.2.89± LINE 2(i) 2(k) 0.8 thermally protected on both poles 2 2(i) 2(k) pole, thermally protected 22(k) thermally protected on one pole only 2 2(i) 2(k) unprotected 2 Style -F7.P (QC 2 x.0) flat head screw ISO580 M.5x5-MS (i) 2(k) Installation drawing 2(i) , When installing the circuit breaker apply pressure on bezel only. operating area LINE 2(i) 2(k) 0 LINE 2(i) 2(k) (QC 2 x.0) flat head screw ISO580 M.5x5-MS Style -F7.Q Panel cut-out LINE 2(i) 2(k) max. R.5 max.059 min. 2 min mounting area max. R0. max (QC 2 x.0) flat head screw ISO580 M.5x5-MS Edges of working parts: DIN 6784 Issue G Germany (0 9 87) USA (847) UK (0296)

8 Thermal Overcurrent Circuit Breaker 20-F7.. Accessories Insulated cover Y Translucent water splash cover (IP54) X Consisting of - Y snap-on frame with actuator guard - Y soft plastic cover Terminal adapter Y R Spacer Y blade terminal DIN C-Ms-S (QC 2x.0) Snap-on frame with actuator guard (can be snapped on as switch-on protection or switch-off protection) Y without bends sharp-edged Rear terminal shroud black (IP64) Y ø8.5 All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved.product markings may not be exactly as the ordering codes. Errors and omissions excepted. 78 Germany (0 9 87) USA (847) UK (0296) Issue G

9 Thermal Overcurrent Circuit Breaker 20-F... Description Switch/thermal trip free circuit breaker (S-type TO CBE to EN 6094) with standard isolator style two button operation. Single button press-to-reset version also available. Both types can be supplied in single pole configuration only, in double pole with single pole protection, and in double pole with protection on both poles. Designed for snap-in panel mounting. There is a choice of push button colour combinations and illumination is optional. Any one of the following additional function modules can be supplied factory fitted to the rear of the switch/circuit breaker: Under voltage release coil (for double pole versions only). Magnetic trip coil for short circuit protection. Magnetic trip coil for remote relay trip. Auxiliary contacts for status signalling. Mechanical slide interlock. Approved to CBE standard EN 6094 (IEC 6094). 20-F... Typical applications Motors, transformers, solenoids, extra low voltage wiring systems, office machines, electro-medical equipment, power supplies, communications systems, industrial controls. Standard current ratings and typical internal resistance values Current Internal resistance Current Internal resistance rating (A) per pole (Ω) rating (A) per pole (Ω) < < < < < < 0.02 Approvals Authority Voltage ratings Current ratings VDE, Semko AC 240 V, DC 28 V A (EN 6094) DC 50 V A 2-polig DC 50 V A -polig BV, LRoS AC 0 V, DC 28 V A UL, CSA AC 0 V, DC 50 V A Illumination voltage/power consumption operating voltage power consumption filament/neon LED 6 V 60 ma 9 ma 2 V 20 ma 9 ma 24 V 20 ma 9 ma 48 V 20 ma.5 ma 5 V < ma < ma* 20 V < ma < ma* 45 V < ma not available * single pole version only Technical data Voltage rating Current ratings Typical life AC 240 V; DC 50 V (AC 45 V to special order) (UL: AC 0 V; DC 50 V) A (up to 0 A to special order, single pole only) 50,000 operations for I N 6A double pole 0,000 operations for I N 6A single pole, 0,000 operations for I N >6 A Ambient temperature C ( F) Insulation co-ordination rated impulse pollution (IEC and A withstand voltage degree 2.5 kv 2 reinforced insulation in operating area Dielectric strength (IEC and 60664A) test voltage operating area AC,000 V between poles (2 pole) AC,500 V Insulation resistance >00 MΩ (DC 500 V) Interrupting capacity I cn A 0 x I N A 0 A or 50 A pole Interrupting capacity I N U N 2 pole (UL 077) A AC 0 V 200 A A AC 0 V,000 A A AC 0 V 2,000 A A AC 0 V,500 A A AC 0 V 5,000 A A DC 50 V,000 A Degree of protection operating area IP40 (IEC 60529/DIN 40050) terminal area IP00 Vibration 8 g ( Hz), ±0.6 mm (0-57 Hz) to IEC , test Fc 0 frequency cycles/axis Shock 0 g ( ms) to IEC , test Ea Corrosion 96 hours at 5 % salt mist, to IEC , test Ka Humidity 240 hours at 95 % RH, to IEC , test Ca Mass approx. g (double pole) approx. 27 g (single pole) Issue G Germany (0 9 87) USA (847) UK (0296)

10 Thermal Overcurrent Circuit Breaker 20-F... Ordering information Type No. 20 push button switch/circuit breaker Mounting F snap in frame Size of frame 2 flange mounting, special frame for fitting splash cover to fit mounting cut-out 50.5x2.5 mm (.99x8.47 in) panel thickness -6.5 mm ( in) Number of poles 0 unprotected, switch only pole, thermally protected 2 thermally protected 5 thermally protected on one pole only (terminals,2k,2i) 6 pole, unprotected, switch only Mounting frame design F with 2 push buttons G with push button (switch-on only) Terminal configuration P7 blade terminals 2x2.8x0.8mm(QC 2x.0) (terminals 2(k), 22(k),, 2), not for under voltage module, not for switch H7 2(k), 22(k): blade terminals 2x (QC 2x.0), 2: terminal screws, not for switch N7 as P7, but including shunt terminals 2(i) and 22 (i) as blade terminals 2x2.8x0.8 mm (QC 2x.0) not for under voltage module G7 as H7, but including shunt terminals 2(i) and 22 (i) as blade terminals 2x2.8x0.8 mm (QC 2x.0) Characteristic curve T thermal,.0-.4 I N Q switch only, only for N7 or G7 terminals Switch style/colour D push button (re-set only) Z push button (momentary switch) 0X black 04X red 2X white translucent 9X green translucent S 2 push buttons on/off GRX green translucent/red WRX white translucent/red WBX white translucent/black Push button illumination (optional) B filament AC/DC L neon, AC G green LED, AC/DC Y yellow LED, AC/DC R red LED, AC/DC Illumination voltage range (optional) V (B,G,Y,R) 0-4 V (B,G,Y,R) V (B,G,Y,R) V (L) V (L) V (B,Y,R) Current ratings A 20 - F 2 F - N7 T - S GRX L 4-0 A ordering example 20 - F 0 F - N7 Q - S A switch only N.B. Switch only versions must be specified with -N7 or -G7 terminals. Terminals 2(k) and 22 (k) are not fitted. Typical time/current characteristics single or double pole 0. 2 A 0000 Trip time in seconds A 0000 Trip time in seconds times rated current times rated current +60 C +40 F +2 C +7.4 F -0 C -22 F +60 C +40 F +2 C +7.4 F -0 C -22 F The time/current characteristic curve depends on the ambient temperature prevailing. In order to eliminate nuisance tripping, please multiply the circuit breaker current ratings by the derating factor shown below. See also section 9 Technical information. Ambient temperature F C Derating factor Germany (0 9 87) USA (847) UK (0296) Issue G

11 Thermal Overcurrent Circuit Breaker 20-F... Dimensions 20-F.F- -S OFF position actuating force max. 5 N optional illumination in ON position (i) 2(k) (QC 2x.0) flat head screw ISO580 M.5x5-MS F.G- -D 0 OFF position optional illumination in ON position t Internal connection diagrams thermally protected on both poles 2 2(i) 2(k) 22(k) thermally protected on one pole only 2 2(i) 2(k) pole, thermally protected unprotected 2 2(i) 2(k) Installation drawing 2(i) When installing the circuit breaker apply pressure on bezel only. operating area.0 2(i) 2(k) (QC 2x.0) flat head screw ISO580 M.5x5-MS 2(i) 2(k) Panel cut-out mounting area 20-F2.F retaining clip panel cover water splash cover (see next page) ±0. 2.6± F max. R2 max max. R0. max.02 min. 2.5 min ø.2.26 PT-screw Typ K40 ø4mm (.57 in.) (QC 2x.0) flat head screw ISO580 M.5x5-MS 2(i) 2(k) F ± R2.079 ø t: metal min. 2 mm (.079 in.) plastic min. mm (.8 in.) Edges of working parts: DIN 6784 Issue G Germany (0 9 87) USA (847) UK (0296)

12 Thermal Overcurrent Circuit Breaker 20-F... Accessories Insulated cover Y Rear terminal shroud black (IP64) Y Terminal adapter Y blade terminal DIN C-Ms-S (QC 2x.0) Spacer for 20-F... Y / R ø ø8.5 Water splash cover, transparent (IP66) for style 20-F2.F-... X consisting of - retaining clip cover Y * * Y suitable for panel thickness < 2 mm (.079 in) * Y suitable for panel thickness < 4 mm (.57 in).4.4 ø Blanking piece in -F frame Y matt finish All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved.product markings may not be exactly as the ordering codes. Errors and omissions excepted. 82 Germany (0 9 87) USA (847) UK (0296) Issue G

13 Auxiliary Contact Module X20-S for circuit breaker 20-F... Description Dimensions A module supplied factory fitted to type 20-F to provide electrically separate changeover contacts which operate as the main contacts open/close. Ideally suited to status signalling and sequence switching. Typical applications Monitoring of the switching position of the circuit breaker or any connected blade terminalsdin A Ms (QC.0) silver plated Ordering information Type No. X20 Module for type 20 and type 40 Function S auxiliary contact module Contact configuration 0 change-over contact Terminal design blade terminals 2.8 x 0.5 (QC.0), silver plated Contact rating AC DC (not approved) Voltage rating Current rating Voltage rating Current rating 2 V A 24 V A A 0 V-0 V A 60 V 0... A 0 V 0...0,5 A 220 V A B 5 V-0 V A 5 V-0 V A Supply condition M module mounted to circuit breaker X20 - S 0 A M ordering example Approvals (complete circuit breaker/module assembly) Authority Voltage ratings Current ratings VDE (EN 6094) AC 0 V, DC 28 V A UL, CSA AC 0 V A Internal connection diagram Technical data Voltage rating Current rating Typical life (i) 2(k) 22(k) AC 0 V; DC 220 V A / A 50,000 operations Module mounted Ambient temperature C ( F) Dielectric strength (IEC and 60664A) test voltage between main and auxiliary circuit AC,000 V Insulation resistance > 00 MΩ (DC 500 V) Vibration 6 g (type X20-S...A) 8 g (type X20-S...B) ( Hz), ±0.46 mm (0-57 Hz) to IEC , test Fc 0 frequency cycles/axis Shock 5 g ( ms), type X20-S...A 20 g ( ms), type X20-S...B to IEC , test Ea Corrosion 96 hours at 5 % salt mist, to IEC , test Ka Humidity 240 hours at 95 % RH to IEC , test Ca Mass approx. 8 g (complete assembly) All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved.product markings may not be exactly as the ordering codes. Errors and omissions excepted. Issue G Germany (0 9 87) USA (847) UK (0296)

14 Undervoltage Release Module X20-U...for circuit breaker 20-F... Description Dimensions A module suitable for all double pole versions of type 20-F to trip the main switch/circuit breaker mechanism in the event of loss of voltage. When the voltage is restored the rocker switch must be reset to reconnect the, thereby avoiding the safety hazards associated with automatic re-starting of machinery. Note: Basic unit H7 or -G7: screw terminals necessary..5.2 flat head screw M.5x5-MS ISO580 for mains connection Typical applications Machines such as power tools, industrial equipment and domestic appliances where automatic restart after restoration of power could be dangerous (EU Machinery Directive) terminals X20-U blade terminal 2 DIN A (QC.0) terminal X20-U0 Without terminal(s): X20-U00 Ordering information Type No. X20 Module for type 20 Function U undervoltage release module Terminal design 00 standard (without separate connections) 0 blade terminal 2.8x0.8 (QC.0) 02 2 blade terminals 2.8x0.8 (QC.0) Voltage ratings 00 AC 20/240 V 50/60 Hz 0 AC 20 V 50/60 Hz 02 AC 00 V 50/60 Hz 0 DC 24 V Assembly status M module mounted to the circuit breaker 20 X20 - U M ordering example Approvals (complete circuit breaker/module assembly) Authority VDE (EN 6094) UL, CSA Voltage ratings AC V; DC 24 V AC V; DC 24 V Internal connection diagrams X20-U00 X20-U0 X20-U02 2 2(i) 2(k) U< 22(k) Technical data Voltage ratings A 2 2(i) 2(k) U< Voltage tolerance +0%/-5% Current consumption Typical life Release values Release delay Latch-in values Ambient temperature Vibration Shock Corrosion Humidity Mass 22(k) A A2 2 2(i) 2(k) U< AC 00, 20 V, 20/240 V 50/60 Hz DC 24 V approx. 2.5 ma 20,000 operations 0.2 x U N < U < 0.7 x U N (at a rated voltage of AC 00 V the device may release at 70 V and must release at 20 V) t < 20 ms 22(k) 85 % U N C ( F) 8 g ( Hz) ±0.6 mm (0-57 Hz) to IEC , test Fc 0 frequency cycles/axis 0 g ( ms) to IEC , test Ea 48 hours at 5 % salt mist, to IEC , test Ka 240 hours at 95% RH to IEC , test Ca approx. 5 g (complete assembly) All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved.product markings may not be exactly as the ordering codes. Errors and omissions excepted. 84 Germany (0 9 87) USA (847) UK (0296) Issue G

15 Remote Trip Module X20-M... for circuit breaker 20-F... Description Dimensions A module which adds remote trip capability to all versions of type 20-F. A voltage applied across the coil, by means of an external sensor for example, will cause disconnection of the main switch/circuit breaker mechanism. 0.8 Typical applications Electrical monitoring of safety systems, remote trip. blade terminals DIN C-Ms-S (QC 2x.0) Ordering information Internal connection diagram Type No. X20 Module for type 20 Function M magnetic relay trip module Style 2 magnetic remote trip coil Terminal design P7 blade terminals 2 x 2.8 x 0.8 (QC 2x.0) tin plated Supply condition M module mounted to the circuit breaker Voltage ratings AC 2, 24, 48, 60, 20, 220, 20, 240 V DC 2, 24 V X20 - M 2 P7 M - 2 V ordering example Standard voltage ratings and typical internal resistance values Voltage Internal Voltage Internal rating resistance per rating resistance per (V) pole (Ω) (V) pole (Ω) 2 V AC/DC V AC V AC/DC. 220 V AC 2 48 V AC.9 20 V AC 2 60 V AC V AC 2 Approvals (complete circuit breaker/module assembly) Authority VDE (EN 6094) UL, CSA Voltage ratings AC V; DC V AC V; DC V Technical data Voltage ratings Power consumption Pulse operation Release delay 2 2(i) 2(k) 22(k) module mounted FA 2(n) remote trip 2 AC V; DC V approx. 200 W 20 ms < t ON <00 ms/t OFF > 0 sec t < 20 ms Typical life 50,000 operations at U N Ambient temperature C ( F) Dielectric strength (IEC and 60664A) test voltage between main circuit and trip coil circuit AC,000 V Insulation resistance >00 MΩ (DC 500 V) Vibration 8 g ( Hz) ±0.6 mm (0-57 Hz) to IEC , test Fc 0 frequency cycles/axis Shock 0 g ( ms) to IEC , test Ea Corrosion 96 hours at 5 % salt mist, to IEC , test Ka Humidity 240 hours at 95 % RH to IEC , test Ca Mass approx. 5 g (complete assembly) All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved.product markings may not be exactly as the ordering codes. Errors and omissions excepted. Issue G Germany (0 9 87) USA (847) UK (0296)

16 Mechanical Slide Interlock Module X20-V...for circuit breaker 20-F... Description Dimensions Suitable for use with all type 20-F versions, this module provides a mechanical safety interlock which, according to the option specified, prevents the main switch/circuit breaker mechanism from being reset/switched on. The actuator is intended for use with interlock systems to ensure that machinery cannot be operated without covers and safety guards in place, for instance. Typical applications custom designed part interlock version Mechanical monitoring of safety systems, e. g. for garden shredders ø4..6 Ordering information Type No. X20 Module for type 20-F Function V mechanical slide interlock module Module operation 20 can only be switched on without the interlock fitted Interlock design 00 without interlock 0 interlock version 0 (see dimension diagram) Delivery condition of interlock L interlock supplied separately with the module M module factory-fitted with the interlock in its centre position O module supplied without interlock Operating direction of interlock 0 without interlock, or interlock supplied separately interlock operated from the side near terminals, 2k, 2i of the interlock operated from the side near terminals 2, 22k, 22i of the Assembly status L module supplied separately M module mounted to the circuit breaker interlock may be moved in either direction min. 8.5 mm (.5 in.) max. 0.5 mm (.4 in.) X20 - V M ordering example All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved.product markings may not be exactly as the ordering codes. Errors and omissions excepted. 86 Germany (0 9 87) USA (847) UK (0296) Issue G

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker 20-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (Stype TO CBE to EN 6094 with trip free mechanism) offering the choice of

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker 20-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (Stype TO CBE to EN 6094 with trip free mechanism) offering the choice of

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker 20-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (S-type TO CBE to EN 6094 with trip free mechanism) offering the choice of

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (S-type TO CBE to EN 6094 with trip free mechanism) offering the choice of single pole, double pole with single pole protection,

More information

Thermal-Magnetic Circuit Breaker M1-..

Thermal-Magnetic Circuit Breaker M1-.. Thermal-Magnetic Circuit Breaker 30-...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker -F... Description An extremely versatile range of rocker switch/thermal circuit breakers (S-type TO CBE to EN 694 with trip free mechanism) offering the choice of single

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker 0-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (S-type TO CBE to EN 6094 with trip free mechanism) offering the choice of

More information

Thermal-Magnetic Circuit Breaker M1-...

Thermal-Magnetic Circuit Breaker M1-... Thermal-Magnetic Circuit Breaker 320-...-M-... Description Two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 6034). The addition of a magnetic tripping

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker 0-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (S-type TO CBE to EN 6094 with trip free mechanism) offering the choice of

More information

Thermal Overcurrent Circuit Breaker 3130

Thermal Overcurrent Circuit Breaker 3130 Thermal Overcurrent Circuit Breaker 330 Description Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting.

More information

Thermal Overcurrent Circuit Breaker 3130

Thermal Overcurrent Circuit Breaker 3130 Thermal Overcurrent Circuit Breaker 330 Description Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 609) of compact design for snap-in panel mounting. Available

More information

Thermal Overcurrent Circuit Breaker 3130

Thermal Overcurrent Circuit Breaker 3130 Description Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 609) of compact design for snap-in panel mounting. Available either with protection on one/both/all

More information

Thermal Circuit Breaker 3120-F...

Thermal Circuit Breaker 3120-F... Description The 320 circuit breaker/switch combination is an ON/OFF switch with integral overcurrent protection (S-type TO CBE to EN/IEC 60934). The trip element is a bimetal. Type 320 is ideally suited

More information

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A Thermal-Magnetic Circuit Breaker 0-S9-P9M-40033-...A Description Single pole thermal-magnetic circuit breaker with trip-free mechanism and toggle actuation. Two-chamber construction with cascade contact

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker

Magnetic and Hydraulic-Magnetic Circuit Breaker Magnetic and Hydraulic-Magnetic Circuit Breaker 845-... Description Single or multipole hydraulic-magnetic circuit breakers with trip-freemechanism and toggle actuation. A choice of switching characteristics

More information

Magnetic Overcurrent Circuit Breaker

Magnetic Overcurrent Circuit Breaker Magnetic Overcurrent Circuit Breaker 808-... Description ngle pole miniaturised magnetic circuit breakers with unique highspeed operating mechanism and push/pull on/off manual actuation. Fitted with electrically

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker

Magnetic and Hydraulic-Magnetic Circuit Breaker Magnetic and Hydraulic-Magnetic Circuit Breaker 835-... Description Single or multipole hydraulic-magnetic circuit breakers with trip-free - mechanism and toggle actuation. A choice of switching characteristics

More information

Thermal Circuit Breaker / Switch Series 3131

Thermal Circuit Breaker / Switch Series 3131 Thermal Circuit Breaker / Switch Series 33 Description Combination of single pole circuit breaker and ON/OFF switch with soft-touch rocker actuation. Contoured rockers are available with a choice of colours

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker

Magnetic and Hydraulic-Magnetic Circuit Breaker Magnetic and Hydraulic-Magnetic Circuit Breaker 835-... Description Single or multipole hydraulic-magnetic circuit breakers with trip-free - mechanism and toggle actuation. A choice of switching characteristics

More information

Thermal Circuit Breaker / Switch Series 3131

Thermal Circuit Breaker / Switch Series 3131 Description Combination of single pole circuit breaker and N/FF switch with soft-touch rocker actuation. Contoured rockers are available with a choice of colours and legends, with optional illumination.

More information

N W. Thermal Circuit Breaker / Switch Series Description. Typical applications Circuit breaker. Technical data

N W. Thermal Circuit Breaker / Switch Series Description. Typical applications Circuit breaker. Technical data Thermal Circuit Breaker / Switch Series 33 Description Combination of single pole circuit breaker and N/FF switch with soft-touch rocker actuation. Contoured rockers are available with a choice of colours

More information

Thermal Circuit Breaker / Switch Series 3131

Thermal Circuit Breaker / Switch Series 3131 Thermal Circuit Breaker / Switch Series 33 Description Combination of single pole circuit breaker and N/FF switch with soft-touch rocker actuation. Contoured rockers are available with a choice of colours

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G V

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G V Description Single and two pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast magnetic only or hydraulically delayed switching characteristics

More information

High Performance Thermal Circuit Breaker

High Performance Thermal Circuit Breaker High Performance Thermal Circuit Breaker 43-... Description Single pole high performance thermal circuit breaker with tease-free, trip-free, snap action mechanism and push/pull on/off manual actuation

More information

Thermal-Magnetic Circuit Breaker 201/-WA

Thermal-Magnetic Circuit Breaker 201/-WA Thermal-Magnetic Circuit Breaker 0/-WA Description Single pole thermal-magnetic circuit breaker with tease-free, trip-free, snap action mechanism and two button operation (M-type TM CBE to EN 60934). Featuring

More information

High Performance Thermal-Magnetic Circuit Breakers 410/520/

High Performance Thermal-Magnetic Circuit Breakers 410/520/ High Performance Thermal-Magnetic Circuit Breakers 0/0/30-... Description Single, double and three pole high performance thermal-magnetic circuit breakers with tease-free, trip-free, snap action mechanism

More information

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Thermal-magnetic Miniature Circuit Breaker 4230-T... Thermal-magnetic Miniature Circuit Breaker 420-T... Description Single pole and multipole thermal-magnetic miniature circuit breakers (MCBs) in accordance with EN 60947-2, UL 077 and UL 489 for DIN rail

More information

Electronic Circuit Breaker ESS20-0..

Electronic Circuit Breaker ESS20-0.. Electronic Circuit Breaker ES-0.. Description Electronic circuit breaker type ES-0.. is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 4 V switch-mode

More information

Electronic Circuit Breaker ESS20

Electronic Circuit Breaker ESS20 Electronic Circuit Breaker ESS20 Description Electronic circuit breaker type ESS20 is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 24 V switch-mode

More information

Simulator switch, magnetic operation

Simulator switch, magnetic operation Description Single pole, miniaturised aircraft simulator switch with extremely fast magnetic trip time. Blade, screw and wire wrap terminals. Aircraft style threadneck and push/pull button with white trip

More information

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Thermal-magnetic Miniature Circuit Breaker 4230-T... Thermal-magnetic Miniature Circuit Breaker 40-T... Description Single pole and multipole thermal-magnetic miniature circuit breakers (MCBs) in accordance with EN 60947-, UL 1077 and UL 489 for DIN rail

More information

Electronic circuit breaker EBU10-T

Electronic circuit breaker EBU10-T Description The electronic circuit protector type EBU10-T (Electronic Breaker Unit) provides selective overcurrent protection in AC 230 V UPS systems. It consists of an MCB approved for short circuit interruptions

More information

TM12 Series CIRCUIT BREAKERS FOR EQUIPMENT. Thermal magnetic release Positively trip-free Reset or manual actuation

TM12 Series CIRCUIT BREAKERS FOR EQUIPMENT. Thermal magnetic release Positively trip-free Reset or manual actuation CIRCUIT BREAKERS FOR EQUIPMENT TM Series Thermal magnetic release Positively trip-free Reset or manual actuation The TM circuit breaker for equipment (CBE) is a single pole, thermal-magnetically operated

More information

CIRCUIT BREAKERS FOR EQUIPMENT, 2 POLE, PUSH BUTTON

CIRCUIT BREAKERS FOR EQUIPMENT, 2 POLE, PUSH BUTTON CIRCUIT BREAKERS FOR EQUIPMENT, POLE, PUSH BUTTON Product description The pole, push button actuated version of the line of thermal CBE s can be used for various purposes. Basically it is a CBE for automatic

More information

TMC 91H is now TMC 60 C Series

TMC 91H is now TMC 60 C Series TMC 91H is now TMC 60 C Series The new Thermal Magnetic Circuit Breaker is once again available and better than ever! The new version is not only UL recognized with the same electrical performance as the

More information

circuit breakers circuit breakers Thermal Circuit Breaker, rocker actuated, 1-, 2- or 3-pole Description Applications

circuit breakers circuit breakers Thermal Circuit Breaker, rocker actuated, 1-, 2- or 3-pole Description Applications circuit breakers Thermal Circuit Breaker, rocker actuated, 1-, 2- or 3-pole TA3 1-pole TA3 2-pole with CZM23 cover TA3 3-pole (pending) Description Thermal circuit breaker 1-, 2- or 3-pole Supplementary

More information

circuit breakers circuit breakers Thermal Circuit Breaker, rocker actuated, 1-, 2- or 3-pole Description Applications TECHNICAL DATA

circuit breakers circuit breakers Thermal Circuit Breaker, rocker actuated, 1-, 2- or 3-pole Description Applications TECHNICAL DATA Thermal Circuit Breaker, rocker actuated, -, 2- or 3-pole TA3 -pole TA3 2-pole TA3 3-pole Description Thermal circuit breaker -, 2- or 3-pole Supplementary protector for general industrial use Positively

More information

circuit breakers circuit breakers Thermal Circuit Breaker, rocker actuated, 1-, 2- or 3-pole Description Applications TeChniCAl DATA

circuit breakers circuit breakers Thermal Circuit Breaker, rocker actuated, 1-, 2- or 3-pole Description Applications TeChniCAl DATA Thermal Circuit Breaker, rocker actuated, -, 2- or -pole TA -pole TA 2-pole TA -pole Description Thermal circuit breaker -, 2- or -pole Supplementary protector for general industrial use Positively trip-free

More information

UMBW-UL489 and UL1077 Listed

UMBW-UL489 and UL1077 Listed -UL489 and UL77 Listed Introducing the New WEG Series Thermal-Magnetic Miniature Breakers. This new offering includes both UL489 and UL77 approvals to provide a solution for circuit & equipment protection

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when

More information

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

The breakers offer thermal-magnetic trip protection according to Z and K characteristics. Series High Performance Circuit Breakers Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific

More information

circuit breakers circuit breakers Thermal Circuit Breaker, rotary knob actuation, 1-, 2- or 3-pole Description Applications

circuit breakers circuit breakers Thermal Circuit Breaker, rotary knob actuation, 1-, 2- or 3-pole Description Applications Thermal Circuit Breaker, rotary knob actuation, -, - or 3-pole -pole standard version 3-pole type without front bezel/knob standard front bezel/knob Description Thermal circuit breaker -, - or 3-pole Supplementary

More information

DD Frame - Series Circuit Breakers

DD Frame - Series Circuit Breakers The DD Frame is a compact yet very powerful circuit breaker. Using the hydraulic-magnetic technology which ensures that the breaker performance is unaffected by ambient temperature, the CI DD Frame series

More information

PB-Series. GFCI/ELCI & Panel Seal

PB-Series. GFCI/ELCI & Panel Seal PB-Series GFCI/ELCI & Panel Seal The PB-Series utilizes the hydraulic magnetic principle which provides precise operation and performance even when exposed to extremely hot and/or cold application environments.

More information

NRA Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

NRA Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute RA Series RA Series Key features of the RA series include: Available in 5 different styles Excellent overload and short circuit protection Small size and high-efficiency Life expectancy of over 0,000 operations

More information

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077 Data Sheet System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077 2CDC021026S0011 2CDC021016S0012 The S 200 PR is a high-performance supplementary protector with

More information

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489 System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU 200 M is ABB s solution for UL 489 branch

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

Section. Circuit Breakers Selection Guide...N-2. NRA Series...N-3. NRBM Series...N-13. NRC Series...

Section. Circuit Breakers   Selection Guide...N-2. NRA Series...N-3. NRBM Series...N-13. NRC Series... Section Selection Guide...-2 RA Series...-3 RBM Series...-3 RC Series...-20 General Instructions...-29 Internal Circuit Overview...-29 for more information on this product family visit www.idec.com/circuitbreaker

More information

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866) .4 Miniature Circuit Breakers and Supplementary Protectors SPHM Supplementary Protector SPHM Supplementary Protector Product Description The SPHM Supplementary Protector is a dual rated product for both

More information

Components for EEx e Panels

Components for EEx e Panels Circuit Interrupters / Motor Switches 8006/3 8543/1 8543/2 8548/2 40 A 63 A 80 A 1 160 A 500 V 660 V 500 V 01766E00 No. of poles 12 poles Isolator features Switching capacity 400 V, AC3 11 kw 22 kw 37

More information

Safety Control HR1S-AC. Safety Relay HR1S-AC

Safety Control HR1S-AC. Safety Relay HR1S-AC HRS-AC Safety Relay HRS-AC Key features: NC or 2NC safety input type, such as E-Stops or Interlock Switches EN ISO 3849- PLe, Safety Cat 3 compliant, and EN 6206 SIL 3 Fault diagnosis function with dual

More information

The specified data apply only if actuators/signal indicators are combined with contact blocks and lamp sockets within the same product range.

The specified data apply only if actuators/signal indicators are combined with contact blocks and lamp sockets within the same product range. General data QR control component range For a mounting hole diameter of.3 mm to IEC 60947 50V/10A max. Water-jet proof IP65 collar shapes The lamps of the pushbuttons can also be replaced from the front

More information

SG-B1 SERIES / SG-A1 SERIES

SG-B1 SERIES / SG-A1 SERIES 643 Door with Solenoid Interlock / Door Ultra-slim SG-B1 SERIES / SG-A1 SERIES Related Information General terms and conditions... F-7 General precautions... P.1501 PHOTO PHOTO Conforming to Machine &

More information

AR circuit breaker - Hydraulic magnetic,

AR circuit breaker - Hydraulic magnetic, AR circuit breaker - Hydraulic magnetic, Datasheet railway, small Features Description Small hydraulic magnetic circuit breaker for railway applications to protect electronic equipment and components against

More information

NRA Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

NRA Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute RA Series RA Series RAS RA Key features of the RA series include: Available in 4 different styles Excellent overload and short circuit protection Small size and high-efficiency Life expectancy of over

More information

RAFIX 22 QR. General data. Content

RAFIX 22 QR. General data. Content QR General data QR control component range For a mounting hole diameter of.3 mm to IEC 60947 50V/10A max. Water-jet proof IP65 collar shapes The lamps of the pushbuttons can also be replaced from the front

More information

max pole for t=15 ms

max pole for t=15 ms Types RI 61 RI 61N RI 61J RI 62 RI 62J RI 63 RI 63N RI 64 single-pole single-pole + neutral pole single-pole (for DC circuits) two-pole two-pole (for DC circuits) three-pole three-pole + neutral pole three-pole

More information

Circuit Breakers. DIN rail-mounted equipment protection

Circuit Breakers. DIN rail-mounted equipment protection Phoenix Contact offers a full family of modular components covering virtually all of your industrial electrical and electronic needs as well as a broad range of value-added services. CLIPLINE DIN rail-mount

More information

FR circuit breaker - hydraulic magnetic,

FR circuit breaker - hydraulic magnetic, FR circuit breaker - hydraulic magnetic, Datasheet railway, very high current Features Ideal for very high current applications Precise, temperature independent operation Panel mount Integrated auxiliary

More information

Selection Guide. Control Circuit and Load Protection

Selection Guide. Control Circuit and Load Protection Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature

More information

18-I73E CAT REF.

18-I73E CAT REF. & www.terasaki.co.jp 1-I73E CAT REF. TABLE OF CONTENTS General 1-1 Introduction 1- General 1-3 Selection Chart 1- Ratings and Specifications -1 Air Circuit Breakers for DC350V-00V - Moulded Case Circuit

More information

Indicator body single with two independent lamp bases, raised, rectangular, black plastic, screw terminals, without bezel. Part No

Indicator body single with two independent lamp bases, raised, rectangular, black plastic, screw terminals, without bezel. Part No Series 03. mm x 4. mm IP40/IP65 0 A 400 VAC Choose one component from each of the coloured sections to assemble a complete switch. For other options or further information please contact your local sales

More information

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions Accessories

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions Accessories Switching & ontrols Selection Guide... 922 1V Series... 923 Dimensions... 929 Accessories... 932 ircuit Breakers Switches & Pilot Lights Signaling Lights Relays & Sockets Timers ontactors Terminal Blocks

More information

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

RX 3 MCB 4500 A Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 RX 3 MCB 4500 A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

15-I73E CAT REF.

15-I73E CAT REF. & www.terasaki.co.jp 5-I7E CAT REF. TABLE OF CONTENTS General - Introduction - General - Selection Chart - Ratings and Specifications - Air Circuit Breakers for DC50V-00V - Moulded Case Circuit Breakers

More information

MOULDED CASE CIRCUIT BREAKERS BC160N

MOULDED CASE CIRCUIT BREAKERS BC160N D MOULDED CASE CIRCUIT BREAKERS BC160N D BC160N COMMERCIAL INFORMATION Circuit breakers...d4 Switch-disconnectors...D5 Connecting sets......d6 Mounting sets......d6 Switches...D7 Shunt trips...d7 Undervoltage

More information

PDR circuit breaker - Ground fault Datasheet

PDR circuit breaker - Ground fault Datasheet - Ground fault Datasheet protection device Features Blue housing 1-3 poles plus neutral 7-100mA Preciese, temperature independent operation Choise of time delays, terminals and actuator colours Application

More information

01 Spectra Plus - Introduction

01 Spectra Plus - Introduction 01 Spectra Plus - Introduction Standard features Conforming to IS13947-2/EN60947 2 Compact dimensions Available in 3P & 4P High performance microprocessor protection release Wide overload setting from

More information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information

Control & Signalling Devices 22.5 mm. RoHS. Compliant

Control & Signalling Devices 22.5 mm. RoHS. Compliant Control & Signalling Devices 22.5 mm RoHS Compliant Contents Characteristics General Characteristics Products Push Buttons, Selector Switches, Latching Mushroom Head Push Buttons, Pilot Lights & Illuminated

More information

SERIES SINGLE AND DOUBLE-POLE PUSHBUTTON SWITCHES

SERIES SINGLE AND DOUBLE-POLE PUSHBUTTON SWITCHES PRODUCT FEATURES Illuminated and non-illuminated pushbutton switch Proven jump contact switching system (double interrupting) Opening and closing speed independent of the actuating speed Product-dependent

More information

14-I73E CAT REF.

14-I73E CAT REF. & www.terasaki.co.jp -I7E CAT REF. TABLE OF CONTENTS General - Introduction - General - Selection Chart - Ratings and Specifications - Air Circuit Breakers for DC50V-00V - Moulded Case Circuit Breakers

More information

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries Safety Relay Unit Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries Two-pole slim models that are only 22.5 mm wide, three-pole models that are only 68 mm wide,

More information

IP20 degree of protection; IP40 degree of protection after installation in a distribution box

IP20 degree of protection; IP40 degree of protection after installation in a distribution box RI 50 RI 50 is used for the protection of installations and devices (overload and short circuit), and as a disconnector in case of electric shock Simple and quick fixing to a 35 mm mounting rail in accordance

More information

EXCEL CELL ELECTRONIC CO., LTD. NO. A S P E C I F I C A T I O N Edition 2 Page 1

EXCEL CELL ELECTRONIC CO., LTD. NO. A S P E C I F I C A T I O N Edition 2 Page 1 S P E C I F I C A T I O N Edition 2 Page 1 ECS - INDUSTRIAL CONTROL SWITCH SELECTOR 1. FEATURES Up to 5 different operations. Detachable contact block for easy installation and removal. It can meet variety

More information

FR circuit breaker - hydraulic magnetic, railway, very high current. Datasheet

FR circuit breaker - hydraulic magnetic, railway, very high current. Datasheet FR circuit breaker - hydraulic magnetic, railway, Datasheet very high current Features Ideal for very high current applications Precise, temperature independent operation Panel mount Integrated auxiliary

More information

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions...

Circuit Breakers. Switching & Controls.  Selection Guide NC1V Series Dimensions... Switching & ontrols Selection Guide... 1028 1V Series... 1029 Dimensions... 1035 www.ide.com/circuitbreaker ircuit Breakers Switches & Pilot Lights Signaling Lights Relays & Sockets Timers ontactors Terminal

More information

Technical Data Accessories MCBs Ex9B.

Technical Data Accessories MCBs Ex9B. Auxiliary and signal contact units AX31, A31, AX31 General parameters With one circuit breaker Ex9B., it can be used up to three contact units with single CO contact or up to two contact units with 2 CO

More information

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters

More information

Power consumption In operation At rest For wire sizing. Connection Motor. Auxiliary switch

Power consumption In operation At rest For wire sizing. Connection Motor. Auxiliary switch echnical data sheet actuator with emergency function for adjusting air dampers in ventilation and air conditioning systems in buildings For air dampers up to approx 4 m 2 orque 20 m ominal voltage AC/DC

More information

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches, 4 Electrics for Rolling Stock Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches, Change-Over-Switches 600 V to 3 kv Catalogue F84.en

More information

cor Long Run Experience

cor Long Run Experience Moulded Case Circuit Breakers Moulded Case Circuit Breakers 16-1250A cor Long Run Experience cor Breaking capacity (according to IEC 947-2 at 415V) Icu 100 D160L D250L D400L D630L 70 60 DH800 50 35 30

More information

3VU13, 3VU16 Circuit-Breakers

3VU13, 3VU16 Circuit-Breakers 3VU3, 3VU6 Circuit-Breakers Description The 3VU3, 3VU6 circuit-breakers are compact circuit-breakers for currents up to 80 A which operate according to the current limiting principle. The devices are used

More information

Bulletin 825 SMM Smart Motor Manager

Bulletin 825 SMM Smart Motor Manager Bulletin 825 SMM Smart Motor Manager Your order must include: Cat. no. of the Smart Motor Manager selected with supply Voltage Suffix Code, Cat. no. of Converter Module selected, and, If required, Cat.

More information

General_technical_data Series

General_technical_data Series Emergency-stop Switching system The double-break switching system can be supplied for the following switching functions: 1 Normally closed, 2 Normally closed, 1 Normally closed + 1 Normally open. The Normally

More information

MINIATURE CIRCUIT BREAKER

MINIATURE CIRCUIT BREAKER Technical Article MINIATURE CIRCUIT BREAKER T 146 PURCHASE he Spaceage MCB protects wires and cables automatically against overload and short-circuits in domestic, commercial and industrial installations.

More information

S200 UL 489 Series. Miniature circuit breakers S200. Features. Description

S200 UL 489 Series. Miniature circuit breakers S200. Features. Description UL 489 Series UL 489 Series Description The Series miniature circuit breaker offers a compact solution for protection requirements. The U AND UP devices are UL 489 tested limiting and DIN rail mounted.

More information

Phase + Neutral, neutral on right side

Phase + Neutral, neutral on right side 87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX 3 MCB 6000 A / 10 ka Cat.. N (s): 4 074 67 / 68 / 69 / 70 / 71 / 72 / 73 / 74 / 75 / 76 / 77 / 78 / 79 ; 4 077 33 / 34

More information

Essential equipment for all your requirements

Essential equipment for all your requirements NEW CTX CONTACTORS Essential equipment for all your requirements 9 A TO 310 A THREE-POLE INDUSTRIAL CONTACTORS CTX three-pole industrial contactors, a sense of family The new range of CTX contactors provides

More information

VEO. V2TF01 Art.Nr.: V2TF01P Art.Nr.: TECHNICAL DATA

VEO. V2TF01 Art.Nr.: V2TF01P Art.Nr.: TECHNICAL DATA P Temperature monitoring (PTC) Short-circuit monitoring Supply voltage 24-240 V AC/DC 1 normally open contact Width 22,5 mm Status indication LED U: Supply voltage LED TFailure: Temperature failure TECHNICAL

More information

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489 MINIATURE CIRCUIT BREAKERS SU200M Datasheet Branch protection acc. to CSA C22.2 No.5 / UL 489 The miniature circuit breaker SU200 M is ABB s solution for UL 489 branch circuit protection up to 480 Y/277

More information

Safety switches with solenoid and separate actuator

Safety switches with solenoid and separate actuator Safety switches with solenoid and separate actuator These switches are used on machines where the hazardous conditions remain for a while, even after the machines have been switched off, for example because

More information

Protection components

Protection components Presentation, characteristics Presentation 1 2 3 motor circuit-breakers are 3-pole thermal-magnetic circuit-breakers standards IEC 60947-2 and IEC 60947-4-1. Connection These circuit-breakers are designed

More information

LK Position Switches TECHNICAL DATASHEET.

LK Position Switches TECHNICAL DATASHEET. LK Position Switches Technopolymer housing, one conduit entry Protection degree IP6 according to EN 60529 contact blocks available 46 actuators available Versions with stainless steel external parts Versions

More information

7000 SERIES ROCKER AND PADDLE SWITCHES Overview

7000 SERIES ROCKER AND PADDLE SWITCHES Overview Overview 7 SERIES Number of poles Terminals 3 Single pole 4 Double pole onsult factory for three and four pole models. Blank W WW Y } Y4 } Y6 } Y7 } Z Solder lugs or straight P depending on model Right

More information

1492-CB 1492-GH 1492-GS

1492-CB 1492-GH 1492-GS 1 The Allen-Bradley Line of Devices Allen-Bradley offers 3 different lines of Circuit Breakers (Supplementary Protectors) and a line of branch circuit rated Fuse Holders. Allen-Bradley Thermal Magnetic

More information

Phase + Neutral, neutral on left side

Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGE 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information