Quality Commitment UL 489 UL 508 UL Equipment Breakers. Earth Leakage. Circuit Breakers

Size: px
Start display at page:

Download "Quality Commitment UL 489 UL 508 UL Equipment Breakers. Earth Leakage. Circuit Breakers"

Transcription

1

2 UL 89 ANNEX Since 98, Altech Corporation has grown to become a leading supplier of automation and industrial control components. Headquartered in Flemington, NJ, Altech has an experienced staff of engineering, manufacturing and sales personnel to provide the highest quality products with superior service. This is the Altech Commitment! With experienced Product Engineers and Customer Service personnel, Altech provides solutions to your most pressing application challenges. All with one thought in mind - to ensure that we solve your problem the first time! Quality Commitment Altech s control components meet diverse national and international standards such as UL, NEC, CSA, IEC, VDE and more. Altech provides superior customer service and delivery through Total Quality Management and Continuous Process Improvement. Altech is ISO 900 approved. We perform these services with honesty and integrity and are committed to achieve these goals. # Altech Corp. 35 Royal Road Flemington, NJ P F

3 Table of Contents The Altech Selection of Breakers...-5 Application Examples UL508A UL89 Miniature Molded Case UL (AC), DL (DC) Series UL89 Miniature Molded Case Circuit Breaker...0- C Trip Characteristic AC...2 D Trip Characteristic AC...3 C Trip Characteristic DC... D Trip Characteristic DC...5 Accessories for UL/DL Series...6 Trip Curves and Technical Data L (AC or DC) Series UL89 Miniature Molded Case Circuit Breaker C Trip Characteristic AC...22 D Trip Characteristic AC...23 C and D Trip Characteristics DC...2 Trip Curves and Technical Data...25 Accessories for L Series UL89 Busbar System Introduction and Ordering Information UL508 Manual Motor Controllers Suitable as Motor Disconnect UM (V-EA) Series UL508 Manual Motor Controllers Suitable as Motor Disconnect B Trip Characteristic...38 C Trip Characteristic...39 D Trip Characteristic...0 E Trip Characteristic... G Trip Characteristic...2 Z Trip Characteristic...3 Trip Curves and Technical Data...-7 MA Series Three Phase Adjustable Trip Miniature /Manual Motor Controllers Accessories V-EA/MA Series MS Series Three Phase Adjustable Trip Economy Manual Motor Controllers...52 Accessories MS Series...53 UL077 Supplementary Protectors UR Series UL077 Supplementary Protectors B Trip Characteristic...56 C Trip Characteristic...57 D Trip Characteristic...58 Accessories UR Series...59 Trip Curves and Technical Data R Series UL077 Supplementary Protectors B Trip Characteristic...6 C Trip Characteristic...65 D Trip Characteristic...66 Trip Curves and Technical Data...67 Accessories UR Series UL077 / UL508 Busbar System Introduction and Ordering Information TR Series UL077 Recognized Supplementary Protector /Circuit Breaker for Equipment RP Series RCCB Circuit Breaker Index Terms and Conditions...9 UL 89 ANNEX Altech Corp. 35 Royal Road Flemington, NJ P F

4 The Altech Selection of Breakers UL 89 The Advantages In today s very competitive marketplace you need reliability, so you need to use circuit breakers that are high quality and technically correct for your application. Altech is a US leader in DIN rail mounted breakers with ratings up to 63A. Only Altech offers DIN rail mounted breakers that meet UL89, UL508 or UL077 approvals with a short circuit interrupt capacity of up to 0kA. No other manufacturer offers this complete line. This assures you the right product for your application requirements. UL (AC), DL (DC), V-EA and UR Series Advantages L and R Series Advantages 5 Hinged terminal cover design allows easy access to terminal screws with a broad range of screwdrivers! 2 Strong thermoplast housing. ANNEX 2 3 UL (AC), DL (DC) Series UL89 Miniature Molded Case ACCESSORIES 3D25UL A B C UL 89 LISTED C.B. E32950 Auxiliary Contact, Alarm Switch Shunt Trip Neutral Pole Undervoltage Trip (not UL) Touch Protection Caps Cooling Spacer Mounting Screw 3mm Lock-out Adapter 2 Individual Part Number is shown on each circuit breaker and is legible when installed in the panel. 3 A clear-hinged cover protects designated marking area. DIN Clip can be released when necessary. 5 Flexible replaceable terminal barriers reduce the possibility of breakage if accidentally dropped! Unique Standard Dual Connection Terminals A Box terminal for solid conductors or flexible conductors with or without cable lug. B Screw terminal for forked cable lug. C Screw terminal for ring tongue connection. IEC Short Circuit Tested L Series, AC or DC UL89 Miniature Molded Case ACCESSORIES LISTED C.B. E30538 Auxiliary Contact Shunt Trip Neutral Pole Undervoltage Trip Front Mounting Kit with hardware Lock-out Adapter 2 Strong terminal barriers. 3 Spring action DIN Rail clips for both top and bottom. 5 Indicator window. 6 Trip curve (D) and amperage (5A) window display. Removable circuit identification tag. ON OFF

5 UM (V-EA) Series UL508 Manual Motor Controllers Suitable as Motor Disconnect ACCESSORIES UL508 Listed E37938 up to 25A B,C,D curve UR Series UL077 Recognized Supplementary Protector E3795 Auxiliary Contact, Alarm Switch Shunt Trip Undervoltage Trip (not UL) Neutral Pole Touch Protection Caps Cooling Spacer Mounting Screw 3mm Lock-out Adapter up to 25A B,C,D curve ACCESSORIES Auxiliary Contact, Alarm Switch Shunt Trip Undervoltage Trip (not UL) Neutral Pole Touch Protection Caps Cooling Spacer Mounting Screw 3mm Lock-out Adapter** R Series UL077 Recognized Supplementary Protector ACCESSORIES Auxiliary Contact Shunt Trip and Undervoltage Trip (not UL) Neutral Pole Lock-out Adapter E306 2 series, 5 lines, 3 UL approvals, AC and DC models and the most trip curves in the industry. Altech has the broadest offering in the industry. UL 89 ANNEX 5

6 UL 89 Typical UL508A Panel ANNEX Disclaimer: This is an application example. Installation should be done by a qualified electrician under the guidance of UL/NEC specifications. 6

7 Variation of UL508A Panel (see NEC article for reference and more information). Disclaimer: This is an application example. Installation should be done by a qualified electrician under the guidance of UL/NEC specifications. UL 89 ANNEX 7

8 UL 89 Typical Motor Group Installation (see NEC article for reference and more information). ANNEX Altech's V-EA UL508 Manual Motor Controllers are approved for Group Installations Disclaimer: This is an application example. Installation should be done by a qualified electrician under the guidance of UL/NEC specifications. 8

9 Typical Motor Group Installation (see NEC article for reference and more information). Altech's V-EA UL508 Manual Motor Controllers are approved for Group Installations UL 89 Disclaimer: This is an application example. Installation should be done by a qualified electrician under the guidance of UL/NEC specifications. ANNEX 9

10 UL 89 ANNEX UL(AC), DL(DC) Series UL89 Miniature Molded Case Available in AC and DC models DIN Rail Mounted 7.5mm width Thermal Magnetic Current Limiting (UL tested) 20V, 80Y/277V AC, 50/60Hz 25V DC ( pole); 250V DC (2 pole) 0kA Short Circuit Interrupting Capacity HACR Type 0 C Line/Load reversible Current/ Voltage Rating UL-Series DL-Series Calibration Temperature Ambient Temperature Storage Temperature Terminal Size Acceptability Terminal Torque (min/max) Electrical Life Mechanical Life Vibration Resistance Resistance to mechanical shocks Degree of protection acc. IEC/EN Mounting Orientation *One device, dual voltage ratings. Short Circuit Interrupting Capacity According to UL 89 No. Poles Type A 0-63A AC 2-3 AC 20, 20, 20, 277V 20V 20, 20, 20 80Y/277V 20V No. Poles Type A 0-63A DC 25V 25V 2 DC 250V 250V C US LISTED C.B. E32950 IEC Short Circuit Tested A/ 20V AC, A/ 80Y/277V AC* (8V DC / pole pending) A/ 25/ 250V DC 0ºC (0ºF) -25ºC to +55ºC (-3ºF to 3ºF ) -0ºC to +70ºC (-0ºF to 58ºF ) Top: 8-3 AWG; Bottom: 8-2 AWG 2 Nm (7.7 lb.in.) / 2.5Nm (22.2 lb.in) 6,000 switching cycles ON/ OFF 0,000 switching cycles ON/ OFF > 5g according to DIN EN during a load with I =.05 x I N ms IP20 In any plane Short Circuit Interrupting Capacity According to IEC , DIN EN No. Poles Type A AC 5kA@20V 5kA@20V 2-3 AC 5kA@5V 0kA@5V 0 Altech Corp. 35 Royal Road Flemington, NJ P F

11 Marking Details Rated Current Approval UL 89 Trip Characteristic Voltage Rating No. of Poles Circuit Diagram Individual Part Number is shown Approval for heating, refrigerating and air conditioning devices. Dimensions in mm 36.5 mm 36.8 mm Trip-Characteristics* Characteristic Trip Boundaries Thermal Trip Must not Trip>00ms 7.5 mm Must Trip <hr C-Characteristics AC C-Characteristics DC D-Characteristics AC.05xRC.35xRC 0xRC 6xRC D-Characteristics DC Magnetic Trip Must not Trip>00ms Must Trip at 00ms.05xRC.35xRC 5xRC 0xRC.05xRC.35xRC 7xRC xrc.05xrc.35xrc xrc 22.xRC 35 mm 52.5 mm Pole 2 Pole 3 Pole Lighting Wiring Protection Control Circuits Business Equipment Appliances Transformers Applications Power Supplies Heaters Low Inrush High Inrush *The value of each characteristic is shown vertically beneath its corresponding heading. Warning! This information should only be used as a selection guide. The use of a Miniature Circuit Breaker in an application with a certain Trip-Characteristic always requires prototype testing! It is the responsibility of the circuit design engineer to select the appropriate Miniature Circuit Breaker for his specific application mm 52.5 mm 3.5 mm.5 mm Motors 30.5 mm 5.5 mm 37.5 mm 25.5 mm mm 68. mm Reactive Load Short Circuit Rating Product Series Telecommunications/ Computer Equipment 5 mm Power Supplies ANNEX Altech Corp. 35 Royal Road Flemington, NJ P F

12 UL 89 UL - Series C-Trip Characteristic Application Examples: Low inrush motors, resistive loads, wiring protection, receptacles, lighting, and control circuit applications. Relatively short thermal trip delay and medium magnetic trip point. C LISTED C.B. US E32950 One Pole Three Pole ANNEX Standard Pack: A:.7kg (3.83lb.) 0-63A:.98kg (.37lb.) Standard Pack: A:.7kg (3.83lb.) 0-63A:.98kg (.37lb.) Rated Type/ Rated Current Cat. No. Voltage 0.3A C03UL 277V AC 0.5A C05UL 277V AC.0A CUL 277V AC.6A C.6UL 277V AC 2.0A C2UL 277V AC 3.0A C3UL 277V AC.0A CUL 277V AC 5.0A C5UL 277V AC 6.0A C6UL 277V AC 8.0A C8UL 277V AC 0A C0UL 277V AC 2A C2UL 277V AC 3A C3UL 277V AC 5A C5UL 277V AC 6A C6UL 277V AC 20A C20UL 277V AC 25A C25UL 277V AC 30A C30UL 277V AC 32A C32UL 277V AC 0A C0UL 20V AC 50A C50UL 20V AC 60A C60UL 20V AC 63A C63UL 20V AC Two Pole Rated Type/ Rated Current Cat. No. Voltage 0.3A 2C03UL 80Y/277V AC 0.5A 2C05UL 80Y/277V AC.0A 2CUL 80Y/277V AC.6A 2C.6UL 80Y/277V AC 2.0A 2C2UL 80Y/277V AC 3.0A 2C3UL 80Y/277V AC.0A 2CUL 80Y/277V AC 5.0A 2C5UL 80Y/277V AC 6.0A 2C6UL 80Y/277V AC 8.0A 2C8UL 80Y/277V AC 0A 2C0UL 80Y/277V AC 2A 2C2UL 80Y/277V AC 3A 2C3UL 80Y/277V AC 5A 2C5UL 80Y/277V AC 6A 2C6UL 80Y/277V AC 20A 2C20UL 80Y/277V AC 25A 2C25UL 80Y/277V AC 30A 2C30UL 80Y/277V AC 32A 2C32UL 80Y/277V AC 0A 2C0UL 20V AC 50A 2C50UL 20V AC 60A 2C60UL 20V AC 63A 2C63UL 20V AC Standard Pack: A:.7kg (3.83lb.) 0-63A:.98kg (.37lb.) Rated Type/ Rated Current Cat. No. Voltage 0.3A 3C03UL 80Y/277V AC 0.5A 3C05UL 80Y/277V AC.0A 3CUL 80Y/277V AC.6A 3C.6UL 80Y/277V AC 2.0A 3C2UL 80Y/277V AC 3.0A 3C3UL 80Y/277V AC.0A 3CUL 80Y/277V AC 5.0A 3C5UL 80Y/277V AC 6.0A 3C6UL 80Y/277V AC 8.0A 3C8UL 80Y/277V AC 0A 3C0UL 80Y/277V AC 2A 3C2UL 80Y/277V AC 3A 3C3UL 80Y/277V AC 5A 3C5UL 80Y/277V AC 6A 3C6UL 80Y/277V AC 20A 3C20UL 80Y/277V AC 25A 3C25UL 80Y/277V AC 30A 3C30UL 80Y/277V AC 32A 3C32UL 80Y/277V AC 0A 3C0UL 20V AC 50A 3C50UL 20V AC 60A 3C60UL 20V AC 63A 3C63UL 20V AC Add-on Neutral Pole Rated Type/ Rated Current Cat. No. Voltage A N32UL 80/277V AC 0-63A N63UL 20V AC Standard Pack: kg (2.8 lb.) Standard Dual Connection Terminal Box clamp terminals Top: 8-3 AWG; Bottom: 8-2 AWG (Line/Load reversible) Ring tongue terminals.3 mm (0. in.) 8.3 mm (0.72 in.) 5.3 mm (0.2 in.) Ring tongue max. 8-2 mm ( in.) M5 screw Box clamp * May differ by manufacturer. Top terminal ring tongue max. thickness.6mm. 2 Altech Corp. 35 Royal Road Flemington, NJ P F

13 UL - Series D-Trip Characteristic Application Examples: High inrush motors, transformers, power supplies, heaters and reactive loads. Relatively long thermal trip delay and very high magnetic trip point. UL 89 C US LISTED C.B. E32950 One Pole Three Pole Standard Pack: A:.7kg (3.83lb.) 0-63A:.98kg (.37lb.) Standard Pack: A:.7kg (3.83lb.) 0-63A:.98kg (.37lb.) Rated Type/ Rated Current Cat. No. Voltage 0.3A D03UL 277V AC 0.5A D05UL 277V AC.0A DUL 277V AC.6A D.6UL 277V AC 2.0A D2UL 277V AC 3.0A D3UL 277V AC.0A DUL 277V AC 5.0A D5UL 277V AC 6.0A D6UL 277V AC 8.0A D8UL 277V AC 0A D0UL 277V AC 2A D2UL 277V AC 3A D3UL 277V AC 5A D5UL 277V AC 6A D6UL 277V AC 20A D20UL 277V AC 25A D25UL 277V AC 30A D30UL 277V AC 32A D32UL 277V AC 0A D0UL 20V AC 50A D50UL 20V AC 60A D60UL 20V AC 63A D63UL 20V AC Two Pole Rated Type/ Rated Current Cat. No. Voltage 0.3A 2D03UL 80Y/277V AC 0.5A 2D05UL 80Y/277V AC.0A 2DUL 80Y/277V AC.6A 2D.6UL 80Y/277V AC 2.0A 2D2UL 80Y/277V AC 3.0A 2D3UL 80Y/277V AC.0A 2DUL 80Y/277V AC 5.0A 2D5UL 80Y/277V AC 6.0A 2D6UL 80Y/277V AC 8.0A 2D8UL 80Y/277V AC 0A 2D0UL 80Y/277V AC 2A 2D2UL 80Y/277V AC 3A 2D3UL 80Y/277V AC 5A 2D5UL 80Y/277V AC 6A 2D6UL 80Y/277V AC 20A 2D20UL 80Y/277V AC 25A 2D25UL 80Y/277V AC 30A 2D30UL 80Y/277V AC 32A 2D32UL 80Y/277V AC 0A 2D0UL 20V AC 50A 2D50UL 20V AC 60A 2D60UL 20V AC 63A 2D63UL 20V AC Standard Pack: A:.7kg (3.83lb.) 0-63A:.98kg (.37lb.) Rated Type/ Rated Current Cat. No. Voltage 0.3A 3D03UL 80Y/277V AC 0.5A 3D05UL 80Y/277V AC.0A 3DUL 80Y/277V AC.6A 3D.6UL 80Y/277V AC 2.0A 3D2UL 80Y/277V AC 3.0A 3D3UL 80Y/277V AC.0A 3DUL 80Y/277V AC 5.0A 3D5UL 80Y/277V AC 6.0A 3D6UL 80Y/277V AC 8.0A 3D8UL 80Y/277V AC 0A 3D0UL 80Y/277V AC 2A 3D2UL 80Y/277V AC 3A 3D3UL 80Y/277V AC 5A 3D5UL 80Y/277V AC 6A 3D6UL 80Y/277V AC 20A 3D20UL 80Y/277V AC 25A 3D25UL 80Y/277V AC 30A 3D30UL 80Y/277V AC 32A 3D32UL 80Y/277V AC 0A 3D0UL 20V AC 50A 3D50UL 20V AC 60A 3D60UL 20V AC 63A 3D63UL 20V AC Add-on Neutral Pole Rated Type/ Rated Current Cat. No. Voltage A N32UL 80/277V AC 0-63A N63UL 20V AC Standard Pack: kg (2.8 lb.) Standard Dual Connection Terminal Box clamp terminals Top: 8-3 AWG; Bottom: 8-2 AWG (Line/Load reversible) Ring tongue terminals.3 mm (0. in.) 8.3 mm (0.72 in.) 5.3 mm (0.2 in.) Ring tongue max. 8-2 mm ( in.) M5 screw Box clamp ANNEX * May differ by manufacturer. Top terminal ring tongue max. thickness.6mm. Altech Corp. 35 Royal Road Flemington, NJ P F

14 UL 89 UL - Series C-Trip (DC) Characteristic Application Examples: Telecommunication equipment, computer equipment, uninterruptable power supplies. ANNEX C US LISTED C.B. E32950 Standard Pack: A:.86kg (.lb.) 0-63A: 2.0kg (.6lb.) One Pole Rated Type/ Rated Current Cat. No. Voltage 0.3A C03DL 25V DC 0.5A C05DL 25V DC.0A CDL 25V DC.6A C.6DL 25V DC 2.0A C2DL 25V DC 3.0A C3DL 25V DC.0A CDL 25V DC 5.0A C5DL 25V DC 6.0A C6DL 25V DC 8.0A C8DL 25V DC 0A C0DL 25V DC 2A C2DL 25V DC 3A C3DL 25V DC 5A C5DL 25V DC 6A C6DL 25V DC 20A C20DL 25V DC 25A C25DL 25V DC 30A C30DL 25V DC 32A C32DL 25V DC 0A C0DL 25V DC 50A C50DL 25V DC 60A C60DL 25V DC 63A C63DL 25V DC Warning! Correct polarity must be observed when connecting the DC circuit breakers Standard Pack: A:.86kg (.lb.) 0-63A: 2.0kg (.6lb.) Two Pole Standard Dual Connection Terminal Box clamp terminals Top: 8-3 AWG; Bottom: 8-2 AWG (Line/Load reversible) Ring tongue terminals.3 mm (0. in.) 8.3 mm (0.72 in.) Rated Type/ Rated Current Cat. No. Voltage 0.3A 2C03DL 250V DC 0.5A 2C05DL 250V DC.0A 2CDL 250V DC.6A 2C.6DL 250V DC 2.0A 2C2DL 250V DC 3.0A 2C3DL 250V DC.0A 2CDL 250V DC 5.0A 2C5DL 250V DC 6.0A 2C6DL 250V DC 8.0A 2C8DL 250V DC 0A 2C0DL 250V DC 2A 2C2DL 250V DC 3A 2C3DL 250V DC 5A 2C5DL 250V DC 6A 2C6DL 250V DC 20A 2C20DL 250V DC 25A 2C25DL 250V DC 30A 2C30DL 250V DC 32A 2C32DL 250V DC 0A 2C0DL 250V DC 50A 2C50DL 250V DC 60A 2C60DL 250V DC 63A 2C63DL 250V DC 5.3 mm (0.2 in.) Ring tongue max. 8-2 mm ( in.) M5 screw Box clamp * May differ by manufacturer. Top terminal ring tongue max. thickness.6mm. Altech Corp. 35 Royal Road Flemington, NJ P F

15 UL - Series D-Trip (DC) Characteristic Application Examples: Telecommunication equipment, computer equipment, uninterruptable power supplies. UL 89 C US LISTED C.B. E32950 Standard Pack: A:.86kg (.lb.) 0-63A: 2.0kg (.6lb.) One Pole Rated Type/ Rated Current Cat. No. Voltage 0.3A D03DL 25V DC 0.5A D05DL 25V DC.0A DDL 25V DC.6A D.6DL 25V DC 2.0A D2DL 25V DC 3.0A D3DL 25V DC.0A DDL 25V DC 5.0A D5DL 25V DC 6.0A D6DL 25V DC 8.0A D8DL 25V DC 0A D0DL 25V DC 2A D2DL 25V DC 3A D3DL 25V DC 5A D5DL 25V DC 6A D6DL 25V DC 20A D20DL 25V DC 25A D25DL 25V DC 30A D30DL 25V DC 32A D32DL 25V DC 0A D0DL 25V DC 50A D50DL 25V DC 60A D60DL 25V DC 63A D63DL 25V DC Warning! Correct polarity must be observed when connecting the DC circuit breakers Standard Pack: A:.86kg (.lb.) 0-63A: 2.0kg (.6lb.) Standard Dual Connection Terminal Box clamp terminals Top: 8-3 AWG; Bottom: 8-2 AWG (Line/Load reversible) Ring tongue terminals.3 mm (0. in.) 8.3 mm (0.72 in.) Two Pole Rated Type/ Rated Current Cat. No. Voltage 0.3A 2D03DL 250V DC 0.5A 2D05DL 250V DC.0A 2DDL 250V DC.6A 2D.6DL 250V DC 2.0A 2D2DL 250V DC 3.0A 2D3DL 250V DC.0A 2DDL 250V DC 5.0A 2D5DL 250V DC 6.0A 2D6DL 250V DC 8.0A 2D8DL 250V DC 0A 2D0DL 250V DC 2A 2D2DL 250V DC 3A 2D3DL 250V DC 5A 2D5DL 250V DC 6A 2D6DL 250V DC 20A 2D20DL 250V DC 25A 2D25DL 250V DC 30A 2D30DL 250V DC 32A 2D32DL 250V DC 0A 2D0DL 250V DC 50A 2D50DL 250V DC 60A 2D60DL 250V DC 63A 2D63DL 250V DC 5.3 mm (0.2 in.) Ring tongue max. 8-2 mm ( in.) M5 screw Box clamp * May differ by manufacturer. Top terminal ring tongue max. thickness.6mm. ANNEX Altech Corp. 35 Royal Road Flemington, NJ P F

16 UL 89 C UL/DL Series Accessories US LISTED C.B. ACC. 3NY7 E Auxiliary Contact, Alarm Switch Type/ Cat No. Description Contacts Type Std Pk For mounting instructions please refer to page mm H0UL Auxiliary Contact NO 6 HUL 2 Auxiliary Contacts NO + NC 6 H2UL 3 Auxiliary Contacts NO + 2NC 6 H2UL 3 Auxiliary Contacts 2NO + NC 6 HLSL* Auxiliary/ Signal Contact CO + CO (Signal) 6 87 mm 52.7 mm 6 mm 5 mm ANNEX * UL not approved. Rated Operating Currents Minimum Contact Load Torque Wire Range: Single Wire Stranded Wire Stranded Wire with Ferrule Shunt Trip 0A@20V AC 3A@0V DC A@220V DC 2V DC max. 0.8Nm (7 lb.in).0mm² - 2.5mm² (8- AWG).0mm² -.5mm² (8-6 AWG).0mm² -.5mm² (8-6 AWG) Max. Operating Type/ Cat No. Rated Voltage U N U N Std Pk FA2UL 2V AC/DC.3A 5 FA2UL 2V AC/DC 0.6A 5 FA8UL 8-72V AC/DC 0.2A 5 FA0UL 0V 0-20V AC/DC, 20V 277V AC 277V 5 Undervoltage Trip* Type/ Cat No. Line Voltage V E Std Pk UA20UL 20V AC, 60Hz 5 Reset-Hold Voltage = 0.85 x V E Drop-Out Voltage = 0.35 ~ 0.7 x V E V E = Rated Voltage Neutral Pole Type/ Cat No. Rated Current I N Rated Voltage U N Std Pk N32UL A 80Y/277V AC 6 N63UL 0-63A 20V AC 6 Touch Protection Caps to cover the terminal screw holes on the switching devices, neutral Poles and shunt trips for increased touch protection. Type/ Cat No. Type/ Cat No. Std Pk BS.UL 00 Mounting Screw 3mm to connect the auxiliary contact and shunt trip or neutral Pole to the circuit breaker. Std Pk E Cooling Spacer Type/ Cat No. Type/ Cat No. Std Pk / Lock-out Adapter** Std Pk EASS 0 ** UL and DL series can also be locked in the on and off position by simply using a common lead or meter seal, which gets fed through the hole in the handle and a corresponding hole in the housing. 36.5mm 36.8mm 8.8 mm 2.8 mm 7.5 mm 9 mm 7.5mm 89.5 mm 88 mm 6 mm 05.3mm AWG 23 5 mm 6mm 52.5mm 3.5mm 8mm.5mm 3.6 mm 63.8 mm Dimensions HxxUL. 68. mm 3.8 mm 63.8 mm 2. mm 6 mm Dimensions HLSL. 5.5mm 37.5mm 25.5mm 68. mm Dimensions UA20UL 30.5mm 5.5mm 68.mm Dimensions NxxUL, FAxxUL ca mm 7mm 5 mm 5mm mm 6 Altech Corp. 35 Royal Road Flemington, NJ P F

17 UL Series (AC) Trip Curves C (AC) Trip Curve D (AC) Trip Curve UL xI N xI N 60 0 Tripping time t Seconds Minutes Tripping time t Seconds Minutes x x0-3 Thermal Overload Must Trip < hr = 35% RC Must Not Trip > hr = 05% RC x x0-3 Multiple of Rated Current 0.3A Through 0A Rated Current xI N 60 0 Thermal Overload Must Trip < hr = 35% RC Must Not Trip > hr = 05% RC Multiple of Rated Current 2A Through 63A Rated Current C Magnetic Trip Parameters Rated current 0.3A to 63A.. Hold for a minimum of 00ms at surge of 5 times rated current. 2. Trip in under 00ms at 0 times rated current. Tripping time t Seconds Minutes Tripping time t Seconds Minutes x x0-3 Thermal Overload Must Trip < hr = 35% RC Must Not Trip > hr = 05% RC Multiple of Rated Current xI N x x A Through 0A Rated Current Thermal Overload Must Trip < hr = 35% RC Must Not Trip > hr = 05% RC Multiple of Rated Current 2A Through 63A Rated Current D Magnetic Trip Parameters Rated current 0.3A to 63A.. Hold for a minimum of 00ms at surge of 0 times rated current. 2. Trip in under 00ms at 6 times rated current. ANNEX Altech Corp. 35 Royal Road Flemington, NJ P F

18 UL 89 UL Series (DC) Trip Curves C (DC) Trip Curve D (DC) Trip Curve xI N xI N 60 0 ANNEX Tripping time t Seconds Minutes Tripping time t Seconds Minutes x x0-3 Thermal Overload Must Trip < hr = 35% RC Must Not Trip > hr = 05% RC x0-2 x0-3 Multiple of Rated Current 0.3A Through 0A Rated Current xI N Thermal Overload Must Trip < hr = 35% RC Must Not Trip > hr = 05% RC Multiple of Rated Current 2A Through 63A Rated Current C Magnetic Trip Parameters Rated current 0.3A to 63A.. Hold for a minimum of 00ms at surge of 7 times rated current. 2. Trip in under 00ms at times rated current. Tripping time t Seconds Minutes Tripping time t Seconds Minutes x x0-3 Thermal Overload Must Trip < hr = 35% RC Must Not Trip > hr = 05% RC xI N x x0-3 Multiple of Rated Current 0.3A Through 0A Rated Current Thermal Overload Must Trip < hr = 35% RC Must Not Trip > hr = 05% RC Multiple of Rated Current 2A Through 63A Rated Current D Magnetic Trip Parameters Rated current 0.3A to 63A.. Hold for a minimum of 00ms at surge of times rated current. 2. Trip in under 00ms at 22. times rated current. 8 Altech Corp. 35 Royal Road Flemington, NJ P F

19 UL/ DL Series Internal Resistance Rated Current Trip Characteristic (A) C D (Ohm) (Ohm) / / / UL Series Let-through Energy I 2 t Diagram, D Trip pole Short Circuit Current I [ka] Time Basis: t=8.3ms For other Trip/Pole configurations use the following correction factors: C Trip pole x curve value C Trip 2 pole x curve value C Trip 3 pole x curve value D Trip pole +.00 x curve value D Trip 2 pole x curve value D Trip 3 pole +.08 x curve value UL 89 ANNEX Altech Corp. 35 Royal Road Flemington, NJ P F

20 UL 89 ANNEX L-Series AC or DC Miniature Molded Case UL89 Listed Available in AC and DC models DIN Rail Mounted 7.5mm width Thermal Magnetic 20V, 80Y/277V AC, 50/60Hz 25VDC ( pole); 250VDC (2 pole) 0kA Short Circuit Interrupting Capacity Positive Trip indicator (Green - off/tripped, Red - on) HACR Type 0 C Line/Load reversible AC Version Current/ Voltage Rating DC Version Current/ Voltage Rating Calibration Temperature Operating Temperature Storage Temperature Terminal Size Acceptability and Torque Terminal Protection Degree Electrical Life Mechanical Life Wire Connection Vibration Resistance Mounting Orientation *One device dual voltage ratings. ac - short CirCuit interrupting rating LISTED E30538 No. Poles Type A 33-63A AC 0kA@20, 20, 277V 0kA@20, 20V 2- AC 0kA@20, 20V, 80Y/277V 0kA@20, 20V A/20VAC, A/80Y/277VAC* A/25/250VDC 0 C (0 F) -25 to 60 C (-3 to 0 F) -25 to 75 C (-3 to 67 F) -3 AWG: 7.5 lb-in. (2.0 Nm) 8-6 AWG: 25 lb-in. (2.8 Nm) IP20 at front 6,000 cycles on/off 0,000 cycles on/off copper wire only 60/75 C 3g (8-50Hz) In any plane DC - short CirCuit interrupting rating No. Poles Type A 33-63A DC 0kA@25V 0kA@25V 2 DC 0kA@250V 0kA@250V 20 Altech Corp. 35 Royal Road Flemington, NJ P F

21 Seconds Time t Minutes x x PoLe.5mm (0.57 in.) 2 PoLe.5mm (0.57 in.) 3 PoLe 09mm (.29 in.) Trip-Characteristics* Type Applications Characteristic Trip Boundaries Thermal Trip Must not Trip>00ms 69mm (2.72 in.) 7.5mm (0.69 in.) C Must Trip <hr D Multiple of Rated Current Must not Trip>00ms C-Characteristics D-Characteristics Magnetic Trip Must Trip at 00ms.05xRC.3xRC 5xRC 0xRC.05xRC.3xRC 5xRC 0xRC.05xRC.3xRC 0xRC 6xRC.05xRC.3xRC 0xRC 6xRC AC DC AC DC Time versus Current Trip Curve For the exact trip curve, please refer to page 25. Lighting Wiring Protection Control Circuits Business Equipment Appliances Transformers *The value of each characteristic is shown vertically beneath its corresponding heading. 09mm (.29 in.) 69mm (2.72 in.) 7.5mm (0.69 in.) 35mm (.38 in.) Dimensions in mm side view 6.5mm (0.26 in.) mm (.73 in.) Power Supplies Heaters Low Inrush Motors High Inrush Warning! This information should only be used as a selection guide. The use of a Miniature Circuit Breaker in an application with a certain Trip-Characteristic always requires prototype testing! It is the responsibility of the circuit design engineer to select the appropriate Miniature Circuit Breaker for his specific application. 09mm (.29 in.) 69mm (2.72 in.) 7.5mm (0.69 in.) 35mm (.38 in.) 52.5mm (2.07 in.) 60mm (2.36 in.).5mm (0.57 in.) Reactive Load 5mm (.77 in.) UL 89 ANNEX Altech Corp. 35 Royal Road Flemington, NJ P F

22 UL 89 AC C-Trip Characteristics Application Examples: Low inrush motors, resistive loads, wiring protection, receptacles, lighting, and control circuit applications. Relatively short thermal trip delay and medium magnetic trip point. LISTED E30538 ANNEX One Pole Three Pole Rated Type/ Current Cat. No. 0.2A CU02L 0.5A CU05L.0A CUL.6A CU.6L 2.0A CU2L 3.0A CU3L.0A CUL 5.0A CU5L 6.0A CU6L 8.0A CU8L 0A CU0L 2A CU2L 3A CU3L 5A CU5L 6A CU6L 20A CU20L 25A CU25L 30A CU30L 32A CU32L 0A CU0L 50A CU50L 60A CU60L 63A CU63L Standard Pack: 2.7kg (3.7 lb.) Rated Type/ Current Cat. No. 0.2A 3CU02L 0.5A 3CU05L.0A 3CUL.6A 3CU.6L 2.0A 3CU2L 3.0A 3CU3L.0A 3CUL 5.0A 3CU5L 6.0A 3CU6L 8.0A 3CU8L 0A 3CU0L 2A 3CU2L 3A 3CU3L 5A 3CU5L 6A 3CU6L 20A 3CU20L 25A 3CU25L 30A 3CU30L 32A 3CU32L 0A 3CU0L 50A 3CU50L 60A 3CU60L 63A 3CU63L Standard Pack:.7kg (3.7 lb.) Two Pole Rated Type/ Current Cat. No. 0.2A 2CU02L 0.5A 2CU05L.0A 2CUL.6A 2CU.6L 2.0A 2CU2L 3.0A 2CU3L.0A 2CUL 5.0A 2CU5L 6.0A 2CU6L 8.0A 2CU8L 0A 2CU0L 2A 2CU2L 3A 2CU3L 5A 2CU5L 6A 2CU6L 20A 2CU20L 25A 2CU25L 30A 2CU30L 32A 2CU32L 0A 2CU0L 50A 2CU50L 60A 2CU60L 63A 2CU63L Standard Pack: 6.7kg (3.7 lb.) Four Pole Please contact Altech. For ring tongue terminal version, replace U with R in part number. For example CR20L instead of CU20L. 22 Altech Corp. 35 Royal Road Flemington, NJ P F

23 AC D-Trip Characteristics Application Examples: High inrush motors, transformers, power supplies, heaters and reactive loads. Relatively long thermal trip delay and very high magnetic trip point. UL 89 LISTED E30538 One Pole Three Pole Rated Type/ Current Cat. No. 0.2A DU02L 0.5A DU05L.0A DUL.6A DU.6L 2.0A DU2L 3.0A DU3L.0A DUL 5.0A DU5L 6.0A DU6L 8.0A DU8L 0A DU0L 2A DU2L 3A DU3L 5A DU5L 6A DU6L 20A DU20L 25A DU25L 30A DU30L 32A DU32L 0A DU0L 50A DU50L 60A DU60L 63A DU63L Standard Pack: 2.7kg (3.7 lb.) Rated Type/ Current Cat. No. 0.2A 3DU02L 0.5A 3DU05L.0A 3DUL.6A 3DU.6L 2.0A 3DU2L 3.0A 3DU3L.0A 3DUL 5.0A 3DU5L 6.0A 3DU6L 8.0A 3DU8L 0A 3DU0L 2A 3DU2L 3A 3DU3L 5A 3DU5L 6A 3DU6L 20A 3DU20L 25A 3DU25L 30A 3DU30L 32A 3DU32L 0A 3DU0L 50A 3DU50L 60A 3DU60L 63A 3DU63L Standard Pack:.7kg (3.7 lb.) Two Pole Rated Type/ Current Cat. No. 0.2A 2DU02L 0.5A 2DU05L.0A 2DUL.6A 2DU.6L 2.0A 2DU2L 3.0A 2DU3L.0A 2DUL 5.0A 2DU5L 6.0A 2DU6L 8.0A 2DU8L 0A 2DU0L 2A 2DU2L 3A 2DU3L 5A 2DU5L 6A 2DU6L 20A 2DU20L 25A 2DU25L 30A 2DU30L 32A 2DU32L 0A 2DU0L 50A 2DU50L 60A 2DU60L 63A 2DU63L Standard Pack: 6.7kg (3.7 lb.) Four Pole Please contact Altech. ANNEX For ring tongue terminal version, replace U with R in part number. For example CR20L instead of CU20L. Altech Corp. 35 Royal Road Flemington, NJ P F

24 UL 89 DC C- & D-Trip Characteristics Application Examples: Telecommunication equipment, computer equipment, uninterruptable power supplies. LISTED E30538 ANNEX C-Trip One Pole D-Trip One Pole Rated Type/ Current Cat. No. 0.2A DCCU02L 0.5A DCCU05L.0A DCCUL.6A DCCU.6L 2.0A DCCU2L 3.0A DCCU3L.0A DCCUL 5.0A DCCU5L 6.0A DCCU6L 8.0A DCCU8L 0A DCCU0L 2A DCCU2L 3A DCCU3L 5A DCCU5L 6A DCCU6L 20A DCCU20L 25A DCCU25L 30A DCCU30L 32A DCCU32L 0A DCCU0L 50A DCCU50L 60A DCCU60L 63A DCCU63L Standard Pack: 2.7kg (3.7 lb.) Rated Type/ Current Cat. No. 0.2A DCDU02L 0.5A DCDU05L.0A DCDUL.6A DCDU.6L 2.0A DCDU2L 3.0A DCDU3L.0A DCDUL 5.0A DCDU5L 6.0A DCDU6L 8.0A DCDU8L 0A DCDU0L 2A DCDU2L 3A DCDU3L 5A DCDU5L 6A DCDU6L 20A DCDU20L 25A DCDU25L 30A DCDU30L 32A DCDU32L 0A DCDU0L 50A DCDU50L 60A DCDU60L 63A DCDU63L Standard Pack: 2.7kg (3.7 lb.) Two Pole Two Pole Rated Type/ Current Cat. No. 0.2A DC2CU02L 0.5A DC2CU05L.0A DC2CUL.6A DC2CU.6L 2.0A DC2CU2L 3.0A DC2CU3L.0A DC2CUL 5.0A DC2CU5L 6.0A DC2CU6L 8.0A DC2CU8L 0A DC2CU0L 2A DC2CU2L 3A DC2CU3L 5A DC2CU5L 6A DC2CU6L 20A DC2CU20L 25A DC2CU25L 30A DC2CU30L 32A DC2CU32L 0A DC2CU0L 50A DC2CU50L 60A DC2CU60L 63A DC2CU63L Standard Pack: 6.7kg (3.7 lb.) Rated Type/ Current Cat. No. 0.2A DC2DU02L 0.5A DC2DU05L.0A DC2DUL.6A DC2DU.6L 2.0A DC2DU2L 3.0A DC2DU3L.0A DC2DUL 5.0A DC2DU5L 6.0A DC2DU6L 8.0A DC2DU8L 0A DC2DU0L 2A DC2DU2L 3A DC2DU3L 5A DC2DU5L 6A DC2DU6L 20A DC2DU20L 25A DC2DU25L 30A DC2DU30L 32A DC2DU32L 0A DC2DU0L 50A DC2DU50L 60A DC2DU60L 63A DC2DU63L Standard Pack: 6.7kg (3.7 lb.) For ring tongue terminal version, replace U with R in part number. For example CR20L instead of CU20L. 2 Altech Corp. 35 Royal Road Flemington, NJ P F

25 L-Series Trip Curves Rated current In (A) C and D Trip Less than 0A Tripping time t Seconds Minutes C and D Trip 0A and higher C D 0.05 C D Multiple of Rated Current Tripping time t Seconds Minutes rated current allowing forambient temperature I cor(a).05.3 Temperature and Power Loss Specifications Multiple of Rated Current Internal impedance Z(mΩ) char.b,c,d,k PowerLoss B, C, D, K P(W) UL 89 ANNEX Altech Corp. 35 Royal Road Flemington, NJ P F

26 UL 89 Accessories L-Series LISTED E30538 Accessories can be factory or field mount ed on L-Series miniature molded case circuit breakers for enhanced control and mon i tor ing capabilities. Field mounting kits include all necessary parts and in struc tions. Accessories can be gang mount ed on a single controller (the Auxiliary Switch in the outside position). The mounting arrange ment links the internal latch-pins for the tripping mechanisms, ensur ing si mul ta neous trips. Handles are linked to simplify manual resetting. ANNEX Shunt Trip Undervoltage Trip 7.5 mm 7.5 mm 7.5 mm Neutral Pole (63A/20VAC; 32A/80Y/277VAC) Description Type/ Cable Cable Torque Torque Cat. No. Max Min Max Min Neutral ALTN2L 25mm 2 2.5mm 2 2Nm.5Nm 3 AWG 2 AWG 7.5 lb-in 2 lb-in Standard Pack: 0.2kg (2.6 lb.) Shunt Trip and Undervoltage Trip Description Shunt Trip Operational Rated Undervoltage Trip* Type/Cat. No. Voltage Coil Current Type/Cat. No. AC Coil: 2V AC FA2ACL V 6A UV2ACL 2V AC FA2ACL V 2.8A UV2ACL 8V AC FA8ACL V 0.8A UV8ACL 60V AC FA60ACL 2-66V ~0.7A UV60ACL 0V AC FA0ACL 77-2V 0.5A UV0ACL 20V AC FA20ACL 8-32V ~0.5A UV20ACL 230V AC FA230ACL 6-253V 0.6A UV230ACL 277V AC FA277ACL 9-305V ~0.5A UV277ACL 00V AC FA00ACL 280-0V 0.5A UV00ACL DC Coil: 2V DC FA2DCL V ~6A UV2DCL 2V DC FA2DCL V 3A UV2DCL 8V DC FA8DCL V 2A UV8DCL 0V DC FA0DCL 77-2V 0.6A UV0DCL * Reset-Hold Voltage = 0.85 x V E ; Drop-Out Voltage = 0.2 x V E Standard Pack: 0.kg (2.3 lb.) Terminal Size - min/max Terminal Torque - min/max 2.5 mm 2 (2 AWG) / 25mm 2 (3 AWG).5 Nm (2 lb. in.) / 2 Nm (7.5 lb. in.) 26 Altech Corp. 35 Royal Road Flemington, NJ P F

27 Accessories L-Series UL 89 LISTED E mm Auxiliary Contact Description Type/ Cable Cable Torque Torque Cat. No. Max Min Max Min x CO HCOL 2 x CO H2COL x CO, Signal HSTCOL & Test Button Standard Pack: 5 0.5kg (.32 lb.) Wiring Diagram Lock-out Adapter Description Yellow HCOL Auxiliary Switch 2 Standard Pack: 0 50g (.76 oz.) (6A/20V AC; 3A/20V AC; 6A/2V DC; 0.5A/25V DC) Circuit Breaker > Type/ Cat. No. EASS2L 95 Luggage Lock 2.5mm 2 0.5mm 2 0.5Nm 0.33Nm 2 AWG 20 AWG lb-in 3 lb-in H2COL Auxiliary Switch 2 Circuit Breaker > 2 Signal Switch Front Mounting Kit with hardware Description Type/ Weight Cat. No. Pole FMAPL 0g (. oz.) 2 Pole FMA2PL 5g (.59 oz.) 3 Pole FMA3PL 50g (.76 oz.) Standard Pack: HSTCOL Regular Auxiliary Switch 2 Circuit Breaker > 2 ANNEX Altech Corp. 35 Royal Road Flemington, NJ P F

28 UL 89 Altech UL89 Busbar System UL89 recognized E30538 ANNEX UL89 Listed Busbars The Altech Busbar System is an innovative way to jumper up to 57 poles of Miniature Molded Case. The advantages of this busbar system are: 30% Installation time savings Panel space savings Reduced maintenance High electrical ratings UL89 Busbar System Universal UL89 Busbar fits most UL89 Miniature in the market! Please contact Altech for details and further information. Every pin configuration is possible by combination of existing 6, 2 and 8 pin busbars. Power Feeding: Power Feed Lug (5A), Direct Power Feed (5A) UL listed for Altech s L-Series and ABL s UL-Series of Miniature UL listed for use with most popular UL89 Miniature in the market. Technical Specifications Busbars UL89 Material of Busbar Copper Material of Insulation (Housing) Polyamide Electrical Ratings 5A/600V AC/DC Short Circuit Withstand Rating 0kA Applying Standards UL89, VDE0660 Part 00, IEC6079, DIN EN Altech Corp. 35 Royal Road Flemington, NJ P F

29 Altech UL89 Busbar System Power Feed Methods UL 89 End Feed Method P35ULT With the P35ULT Power Feed Lug as a Start/End Feeding Device a maximum input current of 5A per Phase can be achieved. P50ULB 5A per phase 2 3 With the P50ULB Modular Direct Power Feed as a Start/End Feeding Device a maximum input current of 5A per Phase can be achieved. * For complete specifications and description of Feeding Devices see page 33. 5A 5A 5A 5A 2 3 5A per phase (P35ULT) 5A (P50ULB) 5A ANNEX Altech Corp. 35 Royal Road Flemington, NJ P F

30 PHASE BUSBAR 6mm 2 for 5A UL 89 UL89 recognized E mm (3.90 in.) 5.5 mm (0.6 in.) 35 mm (.38 in.) Type/ No. of Length Cat. No. Pins [mm] P6UL3/ mm (0.20 in.) 7.6 mm (0.69 in.) 7 x 7.6 = 88 mm (3.6 in.).5 mm (0.06 in.) max..5 mm (0.06 in.) 3.5mm (0.53 in.) ANNEX UL89 recognized E mm (0.20 in.) 7.6 mm (0.69 in.) Type/ No. of Length Cat. No. Pins [mm] P6UL3/ Example for different No. of Pins eg. pins use x P6UL3/2 + 2x P6UL3/8 ACCESSORIES UL89 recognized E30538 Type/ No. of Length Cat. No. Pins [mm] P6UL3/ mm (0.20 in.) 7.6 mm (0.69 in.) Busbars backwards to one another 30.2 (2.2 in.) 7 x 7.6 = (.78 in.) P6UL3/2 P6UL3/8 P6UL3/8 overlapping No. of overlapping pins of 2 busbars must be a multiplier of the No. of phases Overlapping busbars are backwards to each other 20.6 mm (8.06 in.) 5.5 mm (0.6 in.) 7 x 7.6 = 93.6 mm (7.62 in.).5 mm (0.06 in.) max..5 mm (0.06 in.) Type/Cat. No: P35ULT P50ULB BRUL (3 per strip) Description: Power Feed Lug Modular Direct Power Feed Insulation Cap 5.5 mm (0.6 in.).5 mm (0.06 in.) max..5 mm (0.06 in.) 35 mm (.38 in.) 3.5mm (0.53 in.) 35 mm (.38 in.) 3.5mm (0.53 in.) 30 Altech Corp. 35 Royal Road Flemington, NJ P F

31 2 PHASE BUSBAR 6mm 2 for 5A UL89 recognized E mm (3.90 in.) 5.5 mm (0.6 in.) 35 mm (.38 in.) UL 89 Type/ No. of Length Cat. No. Pins [mm] 2P6UL3/ UL89 recognized E mm (0.20 in.) 7.6 mm (0.69 in.) Type/ No. of Length Cat. No. Pins [mm] 2P6UL3/ Example for different No. of Pins eg. 30 pins use 3x 2P6UL3/2 ACCESSORIES UL89 recognized E30538 Type/ No. of Length Cat. No. Pins [mm] 2P6UL3/ mm (0.20 in.) 7.6 mm (0.69 in.) Busbars backwards to one another 5 mm (0.20 in.) 7.6 mm (0.69 in.) 7 x 7.6 = 88 mm (3.6 in.) 30.2 (2.2 in.) 7 x 7.6 = (.78 in.) 2P6UL3/2 2P6UL3/2 2P6UL3/2 overlapping No. of overlapping pins of 2 busbars must be multiplier of the No. of phases Overlapping busbars are backwards to each other.5 mm (0.06 in.) max..5 mm (0.06 in.) 5.5 mm (0.6 in.).5 mm (0.06 in.) max..5 mm (0.06 in.) Type/Cat. No: P35ULT P50ULB BRUL (3 per strip) Description: Power Feed Lug Modular Direct Power Feed Insulation Cap 3.5mm (0.53 in.) 20.6 mm (8.06 in.) 5.5 mm (0.6 in.) 7 x 7.6 = 93.6 mm (7.62 in.).5 mm (0.06 in.) max..5 mm (0.06 in.) 35 mm (.38 in.) 3.5mm (0.53 in.) 35 mm (.38 in.) 3.5mm (0.53 in.) ANNEX Altech Corp. 35 Royal Road Flemington, NJ P F

32 3 PHASE BUSBAR 6mm 2 for 5A ANNEX UL 89 UL89 listed E mm (3.90 in.) 5.5 mm (0.6 in.) 35 mm (.38 in.) Type/ No. of Length Cat. No. Pins [mm] 3P6UL3/ UL89 listed E30538 Type/ No. of Length Cat. No. Pins [mm] 3P6UL3/ UL89 listed E30538 Type/ No. of Length Cat. No. Pins [mm] 3P6UL3/ ACCESSORIES 5 mm (0.20 in.) 7.6 mm (0.69 in.) 5 mm (0.20 in.) 7.6 mm (0.69 in.) 5 mm (0.20 in.) 7.6 mm (0.69 in.) Example for different No. of Pins eg. 39 pins use x 3P6UL3/2 + 2x 3P6UL3/8 Busbars backwards to one another 3P6UL3/2 3P6UL3/8 3P6UL3/8 7 x 7.6 = 88 mm (3.6 in.) 7 x 7.6 = 93.6 mm (7.62 in.).5 mm (0.06 in.) max..5 mm (0.06 in.) 3.5mm (0.53 in.) 20.6 mm (8.06 in.) 5.5 mm (0.6 in.) 30.2 (2.2 in.) 7 x 7.6 = (.78 in.) overlapping No. of overlapping pins of 2 busbars must be multiplier of the No. of phases Overlapping busbars are backwards to each other.5 mm (0.06 in.) max..5 mm (0.06 in.) Type/Cat. No: P35ULT P50ULB BRUL (3 per strip) Description: Power Feed Lug Modular Direct Power Feed Insulation Cap 5.5 mm (0.6 in.).5 mm (0.06 in.) max..5 mm (0.06 in.) 35 mm (.38 in.) 3.5mm (0.53 in.) 35 mm (.38 in.) 3.5mm (0.53 in.) 32 Altech Corp. 35 Royal Road Flemington, NJ P F

33 Power Feed Devices Easy connection of power supply wires to the busbar/mcb. Power Feed Devices ensure permanent connection. Power Feed Lug UL89 listed E30538 Modular Direct Power Feed UL89 listed E30538 UL 89 Type/Cat. No. P35ULT P50ULB Electrical Ratings 5A/600V AC/DC 5A/600V AC/DC Wire Range -2 AWG Cu - AWG Cu Wire Temperature Rating 75 C 75 C Required Torque Nm (35. lb. in.) 3.5Nm/3 lb. in. (-6AWG) Nm/35. lb. in. (-AWG) 2.5Nm/22 lb. in. Material of Lug Brass Brass Insulation Material Polyamide Polyamide For use with UL89, 2, 3 phase Busbar UL89, 2, 3 phase Busbar Dimensions Assembly Instructions 3P6UL3/2 + 3 x P35ULT Accessories 7.2 mm (2.92 in.) 8.5 mm (.9 in.) Insulation Caps 6.2 mm (0.6 in.) 6. mm (0.63 in.) 6 mm (0.2 in.) mm (0.3 in.) 2.6 mm (0.85 in.) 3.3 mm (.23 in.) 3 mm (0.2 in.) Type/Cat. No: Description: 7.75 mm (0.70 in.) Cable Side 2. mm (0.9 in.) 3P6UL3/2 + 3 x P50ULB Busbar Side Ø3.5 mm (0.53 in.) BRUL (3 per strip) Insulation Cap 3.2 mm (0.00 in.) 5.36 mm (20.22 in.) mm (0.6 in.) 6 mm (0.2 in.) 2.6 mm (0.50 in.) 7.6 mm (0.69 in.) ANNEX Altech Corp. 35 Royal Road Flemington, NJ P F

34 UL 89 ANNEX Altech UL89 Busbar Systems Configuration and Assembly of UL89 Busbars UL89 Busbars are available in 3 different Pin Configurations per Phase, (6, 2 and 8 Pins). The UL89 busbar cannot be cut, since the creepage and clearance distance requirements from UL are too stringent. Therefore, to obtain the desired No. of Pins, Busbar-Pins can be overlapped as explained below: ) Busbars are overlapped backwards to each other. Both Pins of each Busbar fit together in the terminals of the Miniature Circuit Breaker. 2 The Number of overlapping Pins of 2 Busbar must be a multiplier of the Number of Phases to keep existing Phase sequence. (Can be overlapped by more than the number of phases). 3) Any available combination of the 3 different Pin configurations is possible. ) In most cases there is more than combination possible. 5) For more possible configurations see Busbar Selection Table on page 2. Configuration Examples* Phase 2 Phase 3 Phase 6 Pins: 3 x P6UL3/6 22 Pins: 2 x 2P6UL3/2 P6UL3/6 P6UL3/6 P6UL3/6 29 Pins: x P6UL3/2 + x P6UL3/8 P6UL3/8 2P6UL3/2 2P6UL3/2 2P6UL3/8 2P6UL3/2 27 Pins: x 3P6UL3/2 + x 3P6UL3/8 3P6UL3/8 P6UL3/2 2P6UL3/2 36 Pins: 2 x 2P6UL3/2 + x 2P6UL3/8 3P6UL3/2 39 Pins: x 3P6UL3/2 + 2 x 3P6UL3/8 3P6UL3/2 3P6UL3/8 3P6UL3/8 *For Questions, other configurations and detailed information please contact Altech Corp. 3 Altech Corp. 35 Royal Road Flemington, NJ P F

35 Busbar Selection Table No. of Pins Necessary Busbars Phase System 6 x P6UL3/6 7 2x P6UL3/6 8 2x P6UL3/6 9 2x P6UL3/6 0 2x P6UL3/6 2x P6UL3/6 2 x P6UL3/2 3x P6UL3/6 3 2x P6UL3/2 3x P6UL3/6 x P6UL3/6 + x P6UL3/2 2x P6UL3/2 3x P6UL3/6 x P6UL3/6 + x P6UL3/2 5 2x P6UL3/2 3x P6UL3/6 x P6UL3/6 + x P6UL3/2 6 2x P6UL3/2 3x P6UL3/6 x P6UL3/6 + x P6UL3/2 7 2x P6UL3/2 x P6UL3/6 + x P6UL3/2 8 x P6UL3/8 2x P6UL3/2 2x P6UL3/6 + x P6UL3/2 x P6UL3/6 + 2x P6UL3/2 9 2x P6UL3/2 2x P6UL3/8 2x P6UL3/6 + x P6UL3/2 x P6UL3/6 + 2x P6UL3/2 x P6UL3/6 + x P6UL3/8 x P6UL3/2 + x P6UL3/8 20 2x P6UL3/2 2x P6UL3/8 x P6UL3/6 + 2x P6UL3/2 2x P6UL3/6 + x P6UL3/2 x P6UL3/6 + x P6UL3/8 x P6UL3/2 + x P6UL3/8 2 2x P6UL3/2 2x P6UL3/8 2x P6UL3/6 + x P6UL3/2 x P6UL3/6 + 2x P6UL3/2 x P6UL3/6 + x P6UL3/8 x P6UL3/2 + x P6UL3/8 22 2x P6UL3/2 2x P6UL3/8 2x P6UL3/6 + x P6UL3/2 x P6UL3/6 + 2x P6UL3/2 x P6UL3/6 + x P6UL3/8 x P6UL3/2 + x P6UL3/8 23 2x P6UL3/2 2x P6UL3/8 x P6UL3/6 + x P6UL3/8 x P6UL3/2 + x P6UL3/8 2 2x P6UL3/2 2x P6UL3/8 x P6UL3/2 + x P6UL3/8 2x P6UL3/6 + x P6UL3/8 3x P6UL3/2 25 2x P6UL3/2 2x P6UL3/8 x P6UL3/2 + x P6UL3/8 2x P6UL3/6 + x P6UL3/8 3x P6UL3/2 26 2x P6UL3/8 x P6UL3/2 + x P6UL3/8 2x P6UL3/6 + x P6UL3/8 3x P6UL3/2 No. of Necessary Pins Busbars 27 2x P6UL3/8 x P6UL3/2 + x P6UL3/8 2x P6UL3/6 + x P6UL3/8 3x P6UL3/2 28 2x P6UL3/8 x P6UL3/2 + x P6UL3/8 2x P6UL3/6 + x P6UL3/8 3x P6UL3/2 29 2x P6UL3/8 x P6UL3/2 + x P6UL3/8 3x P6UL3/2 30 2x P6UL3/8 3x P6UL3/2 x P6UL3/6 + x P6UL3/2 + x P6UL3/8 2x P6UL3/2 + x P6UL3/8 x P6UL3/2 + 2x P6UL3/8 3 2x P6UL3/8 3x P6UL3/2 x P6UL3/6 + x P6UL3/2 + x P6UL3/8 2x P6UL3/2 + x P6UL3/8 x P6UL3/2 + 2x P6UL3/8 32 2x P6UL3/8 3x P6UL3/2 x P6UL3/6 + x P6UL3/2 + x P6UL3/8 2x P6UL3/2 + x P6UL3/8 x P6UL3/2 + 2x P6UL3/8 33 2x P6UL3/8 3x P6UL3/2 x P6UL3/6 + x P6UL3/2 + x P6UL3/8 2x P6UL3/2 + x P6UL3/8 x P6UL3/2 + 2x P6UL3/8 x P6UL3/2 + 2x P6UL3/8 3 2x P6UL3/8 3x P6UL3/2 x P6UL3/6 + x P6UL3/2 + x P6UL3/8 2x P6UL3/2 + x P6UL3/8 x P6UL3/2 + 2x P6UL3/8 35 2x P6UL3/8 2x P6UL3/2 + x P6UL3/8 x P6UL3/2 + 2x P6UL3/8 36 x P6UL3/6 + 2x P6UL3/8 2x P6UL3/2 + x P6UL3/8 3x P6UL3/8 x P6UL3/2 + 2x P6UL3/8 37 x P6UL3/6 + 2x P6UL3/8 2x P6UL3/2 + x P6UL3/8 3x P6UL3/8 x P6UL3/2 + 2x P6UL3/8 38 x P6UL3/6 + 2x P6UL3/8 2x P6UL3/2 + x P6UL3/8 3x P6UL3/8 x P6UL3/2 + 2x P6UL3/8 39 x P6UL3/6 + 2x P6UL3/8 2x P6UL3/2 + x P6UL3/8 3x P6UL3/8 x P6UL3/2 + 2x P6UL3/8 0 x P6UL3/6 + 2x P6UL3/8 2x P6UL3/2 + x P6UL3/8 x P6UL3/2 + 2x P6UL3/8 3x P6UL3/8 x P6UL3/2 + 2x P6UL3/8 3x P6UL3/8 2 x P6UL3/2 + 2x P6UL3/8 3x P6UL3/8 No. of Necessary Pins Busbars 3 x P6UL3/2 + 2x P6UL3/8 3x P6UL3/8 x P6UL3/2 + 2x P6UL3/8 3x P6UL3/8 5 x P6UL3/2 + 2x P6UL3/8 3x P6UL3/8 6 x P6UL3/2 + 2x P6UL3/8 3x P6UL3/8 7 3x P6UL3/8 8 3x P6UL3/8 9 3x P6UL3/8 50 3x P6UL3/8 5 3x P6UL3/8 52 3x P6UL3/8 2 Phase System 6 x 2P6UL3/6 8 2x 2P6UL3/6 0 2x 2P6UL3/6 2 3x 2P6UL3/6 x 2P6UL3/2 3x 2P6UL3/6 2x 2P6UL3/2 x 2P6UL3/6 + x 2P6UL3/2 6 2x 2P6UL3/2 x 2P6UL3/6 + x 2P6UL3/2 8 x 2P6UL3/8 2x 2P6UL3/2 2x 2P6UL3/6 + x 2P6UL3/2 20 2x 2P6UL3/6 + x 2P6UL3/2 x 2P6UL3/6 + x 2P6UL3/8 2x 2P6UL3/2 2x 2P6UL3/8 x 2P6UL3/2 + x 2P6UL3/8 22 2x 2P6UL3/2 2x 2P6UL3/8 x 2P6UL3/6 + x 2P6UL3/8 x 2P6UL3/2 + x 2P6UL3/8 2 2x 2P6UL3/6 + x 2P6UL3/8 x 2P6UL3/6 + 2x 2P6UL3/2 3x 2P6UL3/2 2x 2P6UL3/8 x 2P6UL3/2 + x 2P6UL3/8 26 2x 2P6UL3/6 + x 2P6UL3/8 x 2P6UL3/6 + 2x 2P6UL3/2 3x 2P6UL3/2 2x 2P6UL3/8 x 2P6UL3/2 + x 2P6UL3/8 28 3x 2P6UL3/2 2x 2P6UL3/8 x 2P6UL3/2 + x 2P6UL3/8 30 x 2P6UL3/6 + x 2P6UL3/2 + x 2P6UL3/8 3x 2P6UL3/2 2x 2P6UL3/2 + x 2P6UL3/8 2x 2P6UL3/8 32 x 2P6UL3/6 + x 2P6UL3/2 + x 2P6UL3/8 3x 2P6UL3/2 2x 2P6UL3/2 + x 2P6UL3/8 2x 2P6UL3/8 3 x 2P6UL3/6 + x 2P6UL3/2 + x 2P6UL3/8 2x 2P6UL3/2 + x 2P6UL3/8 2x 2P6UL3/8 36 x 2P6UL3/6 + 2x 2P6UL3/8 3x 2P6UL3/8 2x 2P6UL3/2 + x 2P6UL3/8 x 2P6UL3/2 + 2x 2P6UL3/8 No. of Necessary Pins Busbars 38 x 2P6UL3/6 + 2x 2P6UL3/8 3x 2P6UL3/8 2x 2P6UL3/2 + x 2P6UL3/8 x 2P6UL3/2 + 2x 2P6UL3/8 0 3x 2P6UL3/8 x 2P6UL3/2 + 2x 2P6UL3/8 2 3x 2P6UL3/8 x 2P6UL3/2 + 2x 2P6UL3/8 3x 2P6UL3/8 x 2P6UL3/2 + 2x 2P6UL3/8 6 3x 2P6UL3/8 8 3x 2P6UL3/8 50 3x 2P6UL3/8 3 Phase System 9 2x 3P6UL3/6 2 x 3P6UL3/2 3x 3P6UL3/6 5 x 3P6UL3/6 + x 3P6UL3/2 2x 3P6UL3/2 8 x 3P6UL3/8 x 3P6UL3/2 + 2x 3P6UL3/6 2x 3P6UL3/2 2 2x 3P6UL3/2 x 3P6UL3/6 + x 3P6UL3/8 x 3P6UL3/2 + x 3P6UL3/8 2x 3P6UL3/8 2 x 3P6UL3/2 + x 3P6UL3/8 2x 3P6UL3/6 + x 3P6UL3/8 x 3P6UL3/6 + 2x 3P6UL3/2 3x 3P6UL3/2 2x 3P6UL3/8 27 x 3P6UL3/2 + x 3P6UL3/8 2x 3P6UL3/8 3x 3P6UL3/2 30 2x 3P6UL3/8 2x 3P6UL3/2 + x 3P6UL3/8 3x 3P6UL3/2 x 3P6UL3/6 + x 3P6UL3/2 + x 3P6UL3/8 33 2x 3P6UL3/8 2x 3P6UL3/2 + x 3P6UL3/8 36 x 3P6UL3/6 + 2x 3P6UL3/8 2x 3P6UL3/2 + x 3P6UL3/8 x 3P6UL3/2 + 2x 3P6UL3/8 3x 3P6UL3/8 39 x 3P6UL3/2 + 2x 3P6UL3/8 3x 3P6UL3/8 2 x 3P6UL3/2 + 2x 3P6UL3/8 3x 3P6UL3/8 5 3x 3P6UL3/8 8 3x 3P6UL3/8 Note: For detailed information and examples see page 20. UL 89 ANNEX Altech Corp. 35 Royal Road Flemington, NJ P F

36 UL 89 ANNEX UM (V-EA) Series UL508 Listed Manual Motor Controllers Suitable as Motor Disconnect DIN Rail Mounted 7.5mm width per pole Thermal Magnetic A / 80Y/277V AC, 50/60Hz 0kA Short Circuit Withstand Capacity Applications Include: AC Motor Starting, Across the Line AC General Use AC Resistance AC Discharge Lamps (Ballast) AC Incandescent Lamps (Tungsten) Current/ Voltage Rating Short Circuit Withstand Rating (UL/CSA - Ratings) Group Short Circuit Withstand Rating (UL/CSA - Ratings) Interrupting Capacity (VDE - Ratings) Calibration Temperature Operating Temperature Storage Temperature Terminal Size Acceptability Terminal Torque (min/max) Horse Power Ratings Mechanical Endurance Ratings Vibration Resistance Degree of protection acc. IEC/EN Mounting Orientation UL508 Listed E37938 up to 25A B,C,D curve up to 25A B,C,D curve A/80Y/277V AC A: pole - 2V DC; 2 Pole - 80V DC 30-60A: pole - 2V DC; 2 Pole - 60V DC A (RC): 0kA with UL-listed RK5 back-up fuse or MCCB 0.3-0A (RC): 0kA; 2-60A (RC): 5kA no branch circuit protection required A (RC): 0kA 0 C (0 F) -25 C to 55 C (-3 F to 3 F) -0 C to 70 C (-0 F to 58 F) Top: 8-3 AWG; Bottom: 8-2 AWG 2 Nm (7.7 lb.in.) / 2.5Nm (22.2 lb.in) see page 6 see page 7 > 5g according to DIN EN during a load with I =.05 x I N IP20 In any plane Short Circuit Withstand Ratings for UM (V-EA) Manual Motor Controller Backup UL-Listed UL-Listed No BCP Trip Protection RK5-Fuse MCCB Required Curve Amp Range up to 0kA up to 0kA up to: all 0.3-0A xrc* xrc* 0kA min 5A, max 70A min 5A, max 70A all 2-30/32A xrc* xrc* 5kA max 25A max 25A all 0-50A xrc* xrc* 5kA max 200A max 200A all 60 / 63A xrc* xrc* 5kA max 250A max 250A *up to nearest rated current 36 Altech Corp. 35 Royal Road Flemington, NJ P F

37 Marking Details Rated Current Approvals UL 89 Trip Characteristic Voltage Rating No. of Poles Circuit Diagram Individual Part Number is shown European Voltage Rating Conforms to European Standard Dimensions in mm 36.5 mm 36.8 mm Trip-Characteristics* Characteristic Trip Boundaries Lighting Business Power Wiring Equipment Thermal Trip Protection Transformers Supplies Magnetic Trip Control Appliances Heaters Must not Must Trip Must not Must Trip Circuits General Trip>00ms <hr Trip>00ms at 00ms B-Characteristics.3xRC.5xRC 3xRC 5xRC C-Characteristics.3xRC.5xRC 5xRC 0xRC D-Characteristics.3xRC.5xRC 0xRC 6xRC E-Characteristics.05xRC.35xRC xrc 8xRC G-Characteristics 7.5 mm Application Overview.05xRC.35xRC 8xRC 0xRC Z-Characteristics.05xRC.35xRC 2xRC 3xRC 35 mm 52.5 mm Pole 2 Pole 3 Pole *The value of each characteristic is shown vertically beneath its corresponding heading. Applications Warning! This information should only be used as a selection guide. The use of a Miniature Circuit Breaker/Manual Motor Controller in an application with a certain Trip-Characteristic always requires prototype testing! It is the responsibility of the circuit design engineer to select the appropriate Miniature Circuit Breaker/Manual Motor Controller for his specific application mm.5 mm Low Inrush 3.5 mm.5 mm Motors High Inrush mm 37.5 mm 25.5 mm mm mm High Efficiency 68. mm Short Circuit Rating European Approval Product Series General Electronics Solenoid 5 mm Semiconductors Components/ devices with Reactive low surgecurrent and Load short circuit withstand capabilities ANNEX Altech Corp. 35 Royal Road Flemington, NJ P F

38 CircuitProtection_206.QXD_CircuitProtection //6 2:22 PM Page 38 Application Examples: Business equipment, wiring protection, lighting, appliances, control circuits, some motors and some electronic applications. Relatively long thermal trip delay but low magnetic trip point. One Pole Standard Pack: 2 0.3A - 32A.75kg (3.86 lb.) 0A - 63A 2.07kg (.56 lb.) Rated Current.0A.6A 2.0A 2.5A 3.0A 3.5A.0A 5.0A 6.0A 0A 3A 5A 6A 20A 25A 30A 32A 0A 50A 60A 63A Type/ Voltage BUM B.6UM B2UM B2.5UM B3UM B3.5UM BUM B5UM B6UM B0UM B3UM B5UM B6UM B20UM B25UZ B30UM B32UM B0UM B50UM B60UM B63UM Approvals Standard Pack: 0.3A - 32A.75kg (3.86 lb.) 0A - 63A 2.07kg (.56 lb.) ANNEX 0.3A - 32A.75kg (3.86 lb.) 0A - 63A 2.07kg (.56 lb.) Rated Current.0A.6A 2.0A 2.5A 3.0A 3.5A.0A 5.0A 6.0A 0A 3A 5A 6A 20A 25A 30A 32A 0A 50A 60A 63A Type/ Cat. No. 3BUM 3B.6UM 3B2UM 3B2.5UM 3B3UM 3B3.5UM 3BUM 3B5UM 3B6UM 3B0UM 3B3UM 3B5UM 3B6UM 3B20UM 3B25UM 3B30UM 3B32UM 3B0UM 3B50UM 3B60UM 3B63UM Approvals Add-on Neutral Pole Rated Type/ Current Cat. No A/ N63UM 80Y/277V Approvals Approvals Standard Pack: kg (.7lb.) Standard Dual Connection Terminal Ring tongue Box clamp terminals Top: 8-3 AWG; Bottom: 8-2 AWG (Line/Load reversible) Box clamp Ring tongue terminals.3 mm (0. in.) 5.3 mm (0.2 in.) Standard Pack: 6 Type/ Cat. No. 2BUM 2B.6UM 2B2UM 2B2.5UM 2B3UM 2B3.5UM 2BUM 2B5UM 2B6UM 2B0UM 2B3UM 2B5UM 2B6UM 2B20UM 2B25UM 2B30UM 2B32UM 2B0UM 2B50UM 2B60UM 2B63UM upto 25A B,C,D curve Three Pole Two Pole Rated Current.0A.6A 2.0A 2.5A 3.0A 3.5A.0A 5.0A 6.0A 0A 3A 5A 6A 20A 25A 30A 32A 0A 50A 60A 63A UL508 Listed E mm (0.72 in.) max. 8-2 mm ( in.) UL 89 V-EA Series B-Trip Characteristic M5 screw * May differ by manufacturer. Top terminal ring tongue max. thickness.6mm. 38 Altech Corp. 35 Royal Road Flemington, NJ P F

39 Application Examples: Low inrush motors, lighting, wiring protection, appliances, business equipment, and control circuit applications. Relatively long thermal trip delay and medium magnetic trip point. Standard Pack: 0.3A - 32A.75kg (3.86 lb.) 0A - 63A 2.07kg (.56 lb.) Two Pole 0.3A - 32A.75kg (3.86 lb.) 0A - 63A 2.07kg (.56 lb.) Type/ Cat. No. 2C03UM 2C05UM 2C075UM 2CUM 2C.6UM 2C2UM 2C2.5UM 2C3UM 2C3.5UM 2CUM 2C5UM 2C6UM 2C8UM 2C0UM 2C3UM 2C5UM 2C6UM 2C20UM 2C25UM 2C30UM 2C32UM 2C0UM 2C50UM 2C60UM 2C63UM Approvals Type/ Cat. No. 3C03UM 3C05UM 3C075UM 3CUM 3C.6UM 3C2UM 3C2.5UM 3C3UM 3C3.5UM 3CUM 3C5UM 3C6UM 3C8UM 3C0UM 3C3UM 3C5UM 3C6UM 3C20UM 3C25UM 3C30UM 3C32UM 3C0UM 3C50UM 3C60UM 3C63UM Add-on Neutral Pole Rated Type/ Current Cat. No A/ N63UM 80Y/277V Approvals Approvals Standard Pack: kg (.7lb.) Standard Dual Connection Terminal Ring tongue Box clamp terminals Top: 8-3 AWG; Bottom: 8-2 AWG (Line/Load reversible) Box clamp Ring tongue terminals.3 mm (0. in.) 5.3 mm (0.2 in.) Standard Pack: 6 Rated Current 0.3A 0.5A 0.75A.0A.6A 2.0A 2.5A 3.0A 3.5A.0A 5.0A 6.0A 8.0A 0A 3A 5A 6A 20A 25A 30A 32A 0A 50A 60A 63A Rated Current 0.3A 0.5A 0.75A.0A.6A 2.0A 2.5A 3.0A 3.5A.0A 5.0A 6.0A 8.0A 0A 3A 5A 6A 20A 25A 30A 32A 0A 50A 60A 63A Approvals 0.3A - 32A.75kg (3.86 lb.) 0A - 63A 2.07kg (.56 lb.) Type/ Cat. No. C03UM C05UM C075UM CUM C.6UM C2UM C2.5UM C3UM C3.5UM CUM C5UM C6UM C8UM C0UM C3UM C5UM C6UM C20UM C25UM C30UM C32UM C0UM C50UM C60UM C63UM Three Pole 8.3 mm (0.72 in.) ANNEX Standard Pack: 2 Rated Current 0.3A 0.5A 0.75A.0A.6A 2.0A 2.5A 3.0A 3.5A.0A 5.0A 6.0A 8.0A 0A 3A 5A 6A 20A 25A 30A 32A 0A 50A 60A 63A upto 25A B,C,D curve One Pole UL508 Listed E37938 max. 8-2 mm ( in.) V-EA Series C-Trip Characteristic UL 89 CircuitProtection_206.QXD_CircuitProtection //6 2:22 PM Page 39 M5 screw * May differ by manufacturer. Top terminal ring tongue max. thickness.6mm. Altech Corp. 35 Royal Road Flemington, NJ P F

40 CircuitProtection_206.QXD_CircuitProtection //6 2:22 PM Page 0 Application Examples: High inrush motors, transformers, power supplies, heaters and reactive loads. Relatively long thermal trip delay and very high magnetic trip point. One Pole Standard Pack: 2 0.3A - 32A.75kg (3.86 lb.) 0A - 63A 2.07kg (.56 lb.) Rated Current 0.3A 0.5A 0.75A.0A.6A 2.0A 2.5A 3.0A 3.5A.0A 5.0A 6.0A 8.0A 0A 3A 5A 6A 20A 25A 30A 32A 0A 50A 60A 63A Type/ Cat. No. D03UM D05UM D075UM DUM D.6UM D2UM D2.5UM D3UM D3.5UM DUM D5UM D6UM D8UM D0UM D3UM D5UM D6UM D20UM D25UM D30UM D32UM D0UM D50UM D60UM D63UM Three Pole Approvals Standard Pack: 0.3A - 32A.75kg (3.86 lb.) 0A - 63A 2.07kg (.56 lb.) Two Pole ANNEX 0.3A - 32A.75kg (3.86 lb.) 0A - 63A 2.07kg (.56 lb.) Type/ Cat. No. 2D03UM 2D05UM 2D075UM 2DUM 2D.6UM 2D2UM 2D2.5UM 2D3UM 2D3.5UM 2DUM 2D5UM 2D6UM 2D8UM 2D0UM 2D3UM 2D5UM 2D6UM 2D20UM 2D25UM 2D30UM 2D32UM 2D0UM 2D50UM 2D60UM 2D63UM Rated Current 0.3A 0.5A 0.75A.0A.6A 2.0A 2.5A 3.0A 3.5A.0A 5.0A 6.0A 8.0A 0A 3A 5A 6A 20A 25A 30A 32A 0A 50A 60A 63A Type/ Cat. No. 3D03UM 3D05UM 3D075UM 3DUM 3D.6UM 3D2UM 3D2.5UM 3D3UM 3D3.5UM 3DUM 3D5UM 3D6UM 3D8UM 3D0UM 3D3UM 3D5UM 3D6UM 3D20UM 3D25UM 3D30UM 3D32UM 3D0UM 3D50UM 3D60UM 3D63UM Approvals Add-on Neutral Pole Rated Type/ Current Cat. No A/ N63UM 80Y/277V Approvals Approvals Standard Pack: kg (.7lb.) Standard Dual Connection Terminal Ring tongue Box clamp terminals Top: 8-3 AWG; Bottom: 8-2 AWG (Line/Load reversible) Box clamp Ring tongue terminals.3 mm (0. in.) 5.3 mm (0.2 in.) Standard Pack: 6 Rated Current 0.3A 0.5A 0.75A.0A.6A 2.0A 2.5A 3.0A 3.5A.0A 5.0A 6.0A 8.0A 0A 3A 5A 6A 20A 25A 30A 32A 0A 50A 60A 63A upto 25A B,C,D curve UL508 Listed E mm (0.72 in.) max. 8-2 mm ( in.) UL 89 V-EA Series D-Trip Characteristic M5 screw * May differ by manufacturer. Top terminal ring tongue max. thickness.6mm. 0 Altech Corp. 35 Royal Road Flemington, NJ P F

41 CircuitProtection_206.QXD_CircuitProtection //6 2:22 PM Page High efficiency motors, which have exceedingly high inrush currents. Relatively short thermal trip delays and very high magnetic trip points. 0.3A - 32A.75kg (3.86 lb.) 0A - 63A 2.07kg (.56 lb.) Two Pole 0.3A - 32A.75kg (3.86 lb.) 0A - 63A 2.07kg (.56 lb.) Type/ Cat. No. 2E03UM 2E05UM 2E075UM 2EUM 2E.6UM 2E2UM 2E2.5UM 2E3UM 2E3.5UM 2EUM 2E5UM 2E6UM 2E8UM 2E0UM 2E2UM 2E3UM 2E5UM 2E6UM 2E20UM 2E25UM 2E30UM 2E32UM 2E0UM 2E50UM 2E60UM 2E63UM Approvals Add-on Neutral Pole Rated Type/ Current Cat. No A/ N63UM 80Y/277V Approvals Approvals Standard Pack: kg (.7lb.) Standard Dual Connection Terminal Ring tongue Box clamp terminals Top: 8-3 AWG; Bottom: 8-2 AWG (Line/Load reversible) Box clamp Ring tongue terminals.3 mm (0. in.) 5.3 mm (0.2 in.) Standard Pack: 6 Rated Current 0.3A 0.5A 0.75A.0A.6A 2.0A 2.5A 3.0A 3.5A.0A 5.0A 6.0A 8.0A 0A 2A 3A 5A 6A 20A 25A 30A 32A 0A 50A 60A 63A Type/ Cat. No. 3E03UM 3E05UM 3E075UM 3EUM 3E.6UM 3E2UM 3E2.5UM 3E3UM 3E3.5UM 3EUM 3E5UM 3E6UM 3E8UM 3E0UM 3E2UM 3E3UM 3E5UM 3E6UM 3E20UM 3E25UM 3E30UM 3E32UM 3E0UM 3E50UM 3E60UM 3E63UM Standard Pack: Rated Current 0.3A 0.5A 0.75A.0A.6A 2.0A 2.5A 3.0A 3.5A.0A 5.0A 6.0A 8.0A 0A 2A 3A 5A 6A 20A 25A 30A 32A 0A 50A 60A 63A Approvals 0.3A - 32A.75kg (3.86 lb.) 0A - 63A 2.07kg (.56 lb.) Type/ Cat. No. E03UM E05UM E075UM EUM E.6UM E2UM E2.5UM E3UM E3.5UM EUM E5UM E6UM E8UM E0UM E2UM E3UM E5UM E6UM E20UM E25UM E30UM E32UM E0UM E50UM E60UM E63UM Three Pole 8.3 mm (0.72 in.) ANNEX Standard Pack: 2 Rated Current 0.3A 0.5A 0.75A.0A.6A 2.0A 2.5A 3.0A 3.5A.0A 5.0A 6.0A 8.0A 0A 2A 3A 5A 6A 20A 25A 30A 32A 0A 50A 60A 63A UL508 Listed E37938 One Pole UL 89 Application Examples: max. 8-2 mm ( in.) V-EA Series E-Trip Characteristic M5 screw * May differ by manufacturer. Top terminal ring tongue max. thickness.6mm. Altech Corp. 35 Royal Road Flemington, NJ P F

42 CircuitProtection_206.QXD_CircuitProtection //6 2:22 PM Page 2 Application Examples: General industrial, including motors, some transformers, solenoids, control circuits, lighting and wiring. Meets the US trip norms with relatively short thermal trip delay and high magnetic trip point. One Pole Standard Pack: 2 0.3A - 32A.75kg (3.86 lb.) 0A - 63A 2.07kg (.56 lb.) Rated Current 0.3A 0.5A 0.8A.0A.6A 2.0A 2.5A 3.0A 3.5A.0A 5.0A 6.0A 8.0A 0A 2A 3A 5A 6A 20A 25A 30A 32A 0A 50A 60A 63A Type/ Cat. No. G03UM G05UM G08UM GUM G.6UM G2UM G2.5UM G3UM G3.5UM GUM G5UM G6UM G8UM G0UM G2UM G3UM G5UM G6UM G20UM G25UM G30UM G32UM G0UM G50UM G60UM G63UM Three Pole Approvals Standard Pack: 0.3A - 32A.75kg (3.86 lb.) 0A - 63A 2.07kg (.56 lb.) Two Pole ANNEX 0.3A - 32A.75kg (3.86 lb.) 0A - 63A 2.07kg (.56 lb.) Type/ Cat. No. 2G03UM 2G05UM 2G08UM 2GUM 2G.6UM 2G2UM 2G2.5UM 2G3UM 2G3.5UM 2GUM 2G5UM 2G6UM 2G8UM 2G0UM 2G2UM 2G3UM 2G5UM 2G6UM 2G20UM 2G25UM 2G30UM 2G32UM 2G0UM 2G50UM 2G60UM 2G63UM Rated Current 0.3A 0.5A 0.8A.0A.6A 2.0A 2.5A 3.0A 3.5A.0A 5.0A 6.0A 8.0A 0A 2A 3A 5A 6A 20A 25A 30A 32A 0A 50A 60A 63A Type/ Cat. No. 3G03UM 3G05UM 3G08UM 3GUM 3G.6UM 3G2UM 3G2.5UM 3G3UM 3G3.5UM 3GUM 3G5UM 3G6UM 3G8UM 3G0UM 3G2UM 3G3UM 3G5UM 3G6UM 3G20UM 3G25UM 3G30UM 3G32UM 3G0UM 3G50UM 3G60UM 3G63UM Approvals Add-on Neutral Pole Rated Type/ Current Cat. No A/ N63UM 80Y/277V Approvals Approvals Standard Pack: kg (.7lb.) Standard Dual Connection Terminal Ring tongue Box clamp terminals Top: 8-3 AWG; Bottom: 8-2 AWG (Line/Load reversible) Box clamp Ring tongue terminals.3 mm (0. in.) 5.3 mm (0.2 in.) Standard Pack: 6 Rated Current 0.3A 0.5A 0.8A.0A.6A 2.0A 2.5A 3.0A 3.5A.0A 5.0A 6.0A 8.0A 0A 2A 3A 5A 6A 20A 25A 30A 32A 0A 50A 60A 63A UL508 Listed E mm (0.72 in.) max. 8-2 mm ( in.) UL 89 V-EA Series G-Trip Characteristic M5 screw * May differ by manufacturer. Top terminal ring tongue max. thickness.6mm. 2 Altech Corp. 35 Royal Road Flemington, NJ P F

43 CircuitProtection_206.QXD_CircuitProtection //6 2:22 PM Page 3 Semiconductors, components which fail-short (vs. fail-open), and components/devices with low surge-current and short circuit withstand capabilities. Relatively short thermal delay and very low magnetic trip point. 0.3A - 32A.75kg (3.86 lb.) 0A - 63A 2.07kg (.56 lb.) Two Pole 0.3A - 32A.75kg (3.86 lb.) 0A - 63A 2.07kg (.56 lb.) Add-on Neutral Pole Rated Type/ Current Cat. No A/ N63UM 80Y/277V Approvals Approvals Standard Pack: kg (.7lb.) Standard Dual Connection Terminal Ring tongue Box clamp terminals Top: 8-3 AWG; Bottom: 8-2 AWG (Line/Load reversible) Box clamp Ring tongue terminals.3 mm (0. in.) 5.3 mm (0.2 in.) Standard Pack: 6 Rated Type/ Current Cat. No. 0.3A 2Z03UM 0.5A 2Z05UM 0.75A 2Z075UM.0A 2ZUM.6A 2Z.6UM 2.0A 2Z2UM 2.5A 2Z2.5UM 3.0A 2Z3UM 3.5A 2Z3.5UM.0A 2ZUM 5.0A 2Z5UM 6.0A 2Z6UM 8.0A 2Z8UM 0A 2Z0UM 2A 2Z2UM 3A 2Z3UM 5A 2Z5UM 6A 2Z6UM 20A 2Z20UM 25A 2Z25UM 30A 2Z30UM 32A 2Z32UM 0A 2Z0UM 50A 2Z50UM Approvals Standard Pack: Rated Type/ Current Cat. No. 0.3A 3Z03UM 0.5A 3Z05UM 0.75A 3Z075UM.0A 3ZUM.6A 3Z.6UM 2.0A 3Z2UM 2.5A 3Z2.5UM 3.0A 3Z3UM 3.5A 3Z3.5UM.0A 3ZUM 5.0A 3Z5UM 6.0A 3Z6UM 8.0A 3Z8UM 0A 3Z0UM 2A 3Z2UM 3A 3Z3UM 5A 3Z5UM 6A 3Z6UM 20A 3Z20UM 25A 3Z25UM 30A 3Z30UM 32A 3Z32UM 0A 3Z0UM 50A 3Z50UM Approvals 0.3A - 32A.75kg (3.86 lb.) 0A - 63A 2.07kg (.56 lb.) Type/ Cat. No. Z03UM Z05UM Z075UM ZUM Z.6UM Z2UM Z2.5UM Z3UM Z3.5UM ZUM Z5UM Z6UM Z8UM Z0UM Z2UM Z3UM Z5UM Z6UM Z20UM Z25UM Z30UM Z32UM Z0UM Z50UM Three Pole 8.3 mm (0.72 in.) ANNEX Standard Pack: 2 Rated Current 0.3A 0.5A 0.75A.0A.6A 2.0A 2.5A 3.0A 3.5A.0A 5.0A 6.0A 8.0A 0A 2A 3A 5A 6A 20A 25A 30A 32A 0A 50A UL508 Listed E37938 One Pole UL 89 Application Examples: max. 8-2 mm ( in.) V-EA Series Z-Trip Characteristic M5 screw * May differ by manufacturer. Top terminal ring tongue max. thickness.6mm. Altech Corp. 35 Royal Road Flemington, NJ P F

44 UL 89 V-EA Trip Curves B Trip Curve C Trip Curve D Trip Curve.3-.5xI N xI N xI N 60 0 ANNEX Tripping time t Seconds Minutes Tripping time t Seconds Minutes x x0-3 Thermal Overload Must Trip < hr = 5% RC Must Not Trip > hr = 3% RC xI N x x0-3 Multiple of Rated Current.0A Through 0A Rated Current Thermal Overload Must Trip < hr = 5% RC Must Not Trip > hr = 3% RC Multiple of Rated Current 3A Through 63A Rated Current B Magnetic Trip Parameters Rated current.0a to 63A.. Hold for a minimum of 00ms at surge of 3 times rated current. 2. Trip in under 00ms at 5 times rated current. Tripping time t Seconds Minutes Tripping time t Seconds Minutes x x0-3 Thermal Overload Must Trip < hr = 5% RC Must Not Trip > hr = 3% RC x x0-3 Multiple of Rated Current 0.3A Through 0A Rated Current.3-.5xI N 60 0 Thermal Overload Must Trip < hr = 5% RC Must Not Trip > hr = 3% RC Multiple of Rated Current 3A Through 63A Rated Current C Magnetic Trip Parameters Rated current 0.3A to 63A.. Hold for a minimum of 00ms at surge of 5 times rated current. 2. Trip in under 00ms at 0 times rated current. Tripping time t Seconds Minutes Tripping time t Seconds Minutes x x0-3 Thermal Overload Must Trip < hr = 5% RC Must Not Trip > hr = 3% RC Multiple of Rated Current x x A Through 0A Rated Current.3-.5xI N 60 0 Thermal Overload Must Trip < hr = 5% RC Must Not Trip > hr = 3% RC Multiple of Rated Current 3A Through 63A Rated Current D Magnetic Trip Parameters Rated current 0.3A to 63A.. Hold for a minimum of 00ms at surge of 0 times rated current. 2. Trip in under 00ms at 6 times rated current. Altech Corp. 35 Royal Road Flemington, NJ P F

45 V-EA Trip Curves UL 89 E Trip Curve G Trip Curve Z Trip Curve xI N xI N xI N 60 0 Seconds Tripping time t Minutes Seconds Tripping time t Minutes x x0-3 Thermal Overload Must Trip < hr = 35% RC Must Not Trip > hr = 05% RC xI N x x Multiple of Rated Current E0.3A-E0A 0.3A Through 0A Rated Current Thermal Overload Must Trip < hr = 35% RC Must Not Trip > hr = 05% RC A 2-50 A Multiple of Rated Current 2A Through 60A Rated Current E Magnetic Trip Parameters Rated Current, 0.3A to 50A, 60/63A (dotted line). Magnetic Trip:. Hold for a minimum of 00ms at surge of times (60A, 0 times) rated current. 2. Trip in under 00ms at 8 times (60A, times) rated current. Seconds Tripping time t Minutes Seconds Tripping time t Minutes x x0-3 Thermal Overload Must Trip = 25% Rated Current Must Not Trip < hr = 35% RC Must Not Trip > hr = 05% RC Must Not Trip = Rated Current xI N x x0-3 Multiple of Rated Current 0.3A Through 0A Rated Current Thermal Overload Must Trip = 25% Rated Current Must Not Trip < hr = 35% RC Must Not Trip > hr = 05% RC Must Not Trip = Rated Current Multiple of Rated Current 2A Through 63A Rated Current G Magnetic Trip Parameters Rated Current, 0.3A to 63A. Magnetic Trip:. Hold for a minimum of 00ms at surge of 8 times rated current. 2. Trip in under 00ms at 0 times rated current. Tripping time t Seconds Minutes Tripping time t Seconds Minutes x x0-3 Thermal Overload Must Trip < hr = 35% RC Must Not Trip > hr = 05% RC x x0-3 Multiple of Rated Current 0.3A Through 0A Rated Current xI N 60 0 Thermal Overload Must Trip < hr = 35% RC Must Not Trip > hr = 05% RC Multiple of Rated Current 2A Through 50A Rated Current Z Trip Parameters Rated Current, 0.3A to 50A. Magnetic Trip:. Hold for a minimum of 00ms at 2 times rated current. 2. Trip in under 00ms at 3 times rated current. ANNEX Altech Corp. 35 Royal Road Flemington, NJ P F

46 UL 89 ANNEX FLA & LRC CONVERTED TO TABLE HORSEPOWER (SEE NOTE #2) USE FLA & LRC RATINGS WHERE NO HP RATING IS GIVEN NOMINAL CIRCUIT VOLTAGE V-EA MOTOR MOTOR RATED NAMEPLATE NAMEPLATE VAC VAC VAC VAC VAC VAC CURRENT FLA STARTING/ (SEE NOTE #) RATING LRC RATING 0.30A 0.30A.80A 0.50A 0.50A 3.00A 0.75A 0.75A.35A 0.80A 0.80A.8A.0A.0A 6.0A.6A.6A 9.6A 2.0A 2.0A 2.0A /6hp /6hp /6hp 2.5A 2.5A 5.0A /6hp /6hp /6hp /6hp /hp 3.0A 3.0A 8.0A /6hp /6hp /hp /hp /3hp 3.5A 3.5A 2.0A /hp /hp /hp /3hp /3hp.0A.0A 2.0A /hp /3hp /3hp /3hp /3hp 5.0A 5.0A 30.0A /6hp /3hp /2hp /2hp /2hp /2hp 6.0A 6.0A 36.0A /hp /2hp /2hp /2hp 3/hp 3/hp 8.0A 8.0A 8.0A /3hp 3/hp 3/hp hp hp hp 0.0A 0.0A 60.0A /2hp hp hp /2hp /2hp 2hp 2.0A 2.0A 72.0A /2hp /2hp /2hp 2hp 2hp 2hp 2.5A 2.5A 75.0A /2hp /2hp /2hp 2hp 2hp 2hp 3.0A 3.0A 78.0A /2hp /2hp /2hp 2hp 2hp 2hp 5.0A 5.0A 90.0A 3/hp 2hp 2hp 2hp 3hp 3hp 6.0A 6.0A 96.0A hp 2hp 2hp 2hp 3hp 3hp 20.0A 20.0A 20.0A /2hp 3hp 3hp 3hp 3hp 3hp 25.0A 25.0A 50.0A 2hp 3hp 3hp 3hp 5hp 5hp 30.0A 30.0A 80.0A 2hp 3hp 3hp 5hp 5hp 5hp 32.0A 32.0A 92.0A 2hp 3hp 5hp 5hp 5hp 5hp 0.0A 0.0A 20.0A 3hp 5hp 7/2hp 7/2hp 7/2hp 7/2hp 50.0A 50.0A 300.0A 3hp 7/2hp 0hp 0hp 0hp 0hp 60.0A 60.0A 360.0A 5hp 0hp 0hp 0hp 0hp 5hp NOTE #: For AC motor circuit nameplate full load current, AC general-use loads, AC resistance loads, AC incandescent lamp (tungsten) loads, AC electric discharge lamp (ballast) loads. NOTE #2: Conversions per UL508 Table 5.2 and NFPA-70: National Electrical Code 20 Tables and 30-25(A). FLA & LRC RATINGS CONVERTED TO TABLE HORSEPOWER (SEE NOTE #2) USE FLA & LRC RATINGS WHERE NO HP IS LISTED V-EA MOTOR MOTOR VAC 0-80 RATED NAMEPLATE NAMEPLATE VAC VAC VAC (SEE NOTE #3) VAC CURRENT FLA STARTING/ Motor Design Motor Design Motor Design Motor Design Motor Design (SEE NOTE #) RATING LRC RATING B, C, D E B, C, D E B, C, D E B, C, D E B, C, D E 0.30A 0.30A 3.0A 0.50A 0.50A 5.0A 0.75A 0.75A 7.5A 0.80A 0.80A 8.0A.0A.0A 0.0A.6A.6A 6.0A /2hp /2hp 2.0A 2.0A 20.0A /2hp /2hp 3/hp 3/hp 2.5A 2.5A 25.0A /2hp /2hp /2hp /2hp /2hp /2hp hp hp 3.0A 3.0A 30.0A /2hp /2hp /2hp /2hp /2hp /2hp /2hp /2hp 3.5A 3.5A 35.0A /2hp /2hp 3/hp 3/hp 3/hp 3/hp 2hp 2hp.0A.0A 0.0A 3/hp 3/hp 3/hp 3/hp 3/hp 3/hp 2hp 2hp 5.0A 5.0A 2.0A /2hp /2hp hp hp hp hp hp hp 3hp 3hp 6.0A 6.0A 50.A /2hp /2hp hp hp hp hp /2hp /2hp 3hp 3hp 8.0A 8.0A 67.2A 3/hp 3/hp 2hp 2hp 2hp 2hp 2hp 2hp 5hp 5hp 0.0A 0.0A 8.0A hp hp 2hp 2hp 2hp 2hp 3hp 3hp 5hp 5hp 2.0A 2.0A 00.8A /2hp /2hp 3hp 3hp 3hp 3hp 3hp 3hp 7/2hp 7/2hp 2.5A 2.5A 05.0A /2hp /2hp 3hp 3hp 3hp 3hp 3hp 3hp 7/2hp 7/2hp 3.0A 3.0A 09.2A /2hp /2hp 3hp 3hp 3hp 3hp 3hp 3hp 7/2hp 7/2hp 5.0A 5.0A 26.0A 2hp 2hp 3hp 3hp 3hp 3hp 3hp 3hp 0hp 0hp 6.0A 6.0A 3.A 2hp 2hp 3hp 3hp 3hp 3hp 5hp 5hp 0hp 0hp 20.0A 20.0A 68.0A 3hp 3hp 5hp 5hp 5hp 5hp 5hp 5hp 0hp 0hp 25.0A 25.0A 20.0A 3hp 3hp 5hp 5hp 7/2hp 7/2hp 7/2hp 7/2hp 5hp 5hp 30.0A 30.0A 252.0A 5hp 5hp 5hp 5hp 7/2hp 7/2hp 0hp 0hp 20hp 20hp 32.0A 32.0A 268.8A 5hp 5hp 5hp 5hp 0hp 0hp 0hp 0hp 20hp 20hp 0.0A 0.0A 226.0A 5hp 5hp 0hp 7/2hp 0hp 7/2hp 0hp 0hp 30hp 20hp 50.0A 50.0A 282.5A 7/2hp 7/2hp 5hp 0hp 5hp 0hp 5hp 0hp 30hp 25hp 60.0A 60.0A 339.0A 0hp 0hp 5hp 0hp 20hp 0hp 20hp 5hp 0hp 30hp NOTE #: NOTE #2: Table HP : AMPERE RATINGS & HORSEPOWER RATING PHASE TABLE HP 2: AMPERE RATING & HORSEPOWER RATING 3 PHASE & 2 PHASE - WIRE For AC motor circuit nameplate full load current, AC general-use loads, AC resistance loads, AC incandescent lamp (tungsten) loads, AC electric discharge lamp (ballast) loads. Conversions per UL508 proposed Tables 5.2 and 5. and NFPA-70: National Electrical Code 20 Tables 30-29, and 30-25(B). 6 Altech Corp. 35 Royal Road Flemington, NJ P F

47 V-EA INTERNAL RESISTANCE Trip Characteristic Rated Current B C D E G Z (Amp) (Ohms) (Ohms) (Ohms) (Ohms) (Ohms) (Ohms) / / / / / LINE CURRENT FREQUENCY EF FECTS ON TRIP CURVES Frequency Effects on Magnetic Trip Curves Trip Trip Zone Trip Zone Trip Zone Trip Zone Trip Zone Curve At At At At At 6 2/3-60Hz 00 Hz 200 Hz 00 Hz DC (x RC) (x RC) (x RC) (x RC) (x RC) Z B C G D E Resistances listed are hot values, as opposed to cold start values. Operating voltage drop across the V-EA and power loss per pole can be approximated with basic formulas: V DROP = I OPERATING x R TABLE P LOSS P/P = I 2 OPERATING x R TABLE Voltage drops should be reviewed when V-EAs with high internal resistance are used (e.g., load voltage minimums). Power loss should be reviewed when V-EAs with high rated currents are used (e.g., enclosure heating). The listed V-EA internal resistance values should not be used in calculations of available shortcircuit current downstream of the V-EA. The dynamic impedance of the V-EA under short-circuit conditions can vary significantly from internal resistance values in normal operation. The thermal trip is not affected by the frequency of the line current. The magnetic trip is within the trip zone of the characteristic curve for frequencies from 6 2/3 to 60Hz. At lower and higher frequencies, the magnetic trip will be delayed longer than in di cat ed by the char ac ter is tic curve, roughly as follows: At 00Hz: Mag. Trip Current =. x curve current At 200Hz: Mag. Trip Current =.2 x curve current At 00Hz: Mag. Trip Current =. x curve current At DC: Mag. Trip Current =.5 x curve current For ex am ple, at 6 2/3-60 Hz the mag net ic trip zone for the G char ac ter is tic is 8 to 0 times the rated current of the specific V-EA (i.e., hold for at least 00ms at 8 x RC, trip in less than 00ms at 0 x RC). With a 00Hz current, a magnetic trip at 0 x RC would be greatly delayed (thermal would likely trip first), as the magnetic trip zone is now.2 to x RC. If a quicker magnetic trip is required with 00Hz, the B or C characteristic should be considered. MECHANICAL ENDURANCE RATINGS (ON/OFF OPERATIONS) Application 2 x (.5 x RC) 2 x RC RC No Load Total AC General Use 6,000,000 0,000 AC Motor Starting Across the Line,000 5,000,000 0,000 AC Incandescent Lamps (Tungsten) 6,000,000 0,000 AC Electrical Discharge Lamps (Ballast) 6,000,000 0,000 AC Resistance 6,000,000 0,000 Manufacturers self certification ON/OFF operations with no load UL 89 ANNEX Altech Corp. 35 Royal Road Flemington, NJ P F

48 UL 89 MA- Series Three Phase Adjustable Trip Miniature / Manual Motor Controllers UL508 listed E37938 CAN/CSA-C22.2 No. certified ANNEX The MA was designed to handle the high inrush loads of 3 phase trans form ers, power sup plies, motors, etc. The MA protects wir ing and equip ment from damage caused by the three major classes of over-cur rent, yet greatly re duc - es the number of nui sance trips in high start ing and inrush current cir cuits. An IEC device with excellent rat ings under a UL listing at 80Y/277V (in clud ing group ratings) and at 500V under international standards, the Altech/ABL Sursum MA pro vides short and long term cost ef fec tive circuit protec tion for USA and/or export applications. The short term ad van tag es include: () ad just able ther mal trip al lows final iza tion of initial de signs be fore procurement of the load equip ment is complete; (2) snap-on mount ing for readily available, in ter na tion al ly stan dard ized DIN Rail saves panel layout design time as well as in stal la tion and change la bor; (3) large cage-clamp ter mi nals with screws suit able to power screw driv ers, sim pli fies and speeds wiring; () convenient switched dis con nect during fac to ry test ing and/or initial start-up saves time and ag gra va tion. The key long term advantage is cus tom er sat is fac tion and proven over-cur rent pro - tec tion of wiring and equip ment (and the lack of rework/re pair costs). Cat. No. Rated Current FLA Dial Adjustment Markings MA06UM 0.6A 0./ 0.2/0./0.6 MA025UM 0.25A 0.6/0.9/0.22/0.25 MA00UM 0.0A 0.25/0.30/0.35/0.0 MA063UM 0.63A 0.0/0.8/0.56/0.63 MA.0UM.0A 0.63/0.75/0.87/.0 MA.6UM.6A.0/.2/./.6 MA2.5UM 2.5A.6/.9/2.2/2.5 MA.0UM.0A 2.5/3.0/3.5/.0 MA6.3UM 6.3A.0/.8/5.6/6.3 MA0UM 0A 6.3/7.5/8.7/0 MA6UM 6A 0/2//6 MA20UM 20A 6/7/8.5/20 MA25UM 25A 20/2.5/23/25 MA32UM 32A 25/27/30/32 MA0UM 0A 32/3/37/0 Type Designation MA 6 U M (a) (b) (c) (d) (a) (b) (c) (d) = MA - Manual Motor Controller = Rated Current = U - US Housing = R - US Housing + Ring Tongue = M - Part No. Designation Voltage Rating AIC (Interrupt Capacity) Standard Short Circuit Withstand Rating (UL/CSA Ratings) Group Short Circuit Ratings (UL/CSA Ratings) Typical Life Calibration Temperature Standard Pack and Weight Terminal Size Acceptability Terminal Torque (min/max) GROUP SHORT CIRCUIT RATING AT 80VAC a (and BCP size) 2kArMs symmetrical (max. 200A MCCB or RK5) karms symmetrical (max. 350A MCCB or RK5) 0kARMS symmetrical (max. 350A MCCB or RK5) 3Ø HORSEPOWER RATINGS AT NOMINAL LINE VOLTAGE (See Note for HEA Definition) 0-20V HP (HEA) 80Y/277V AC 0.6A-2.5A: 2kA;.0A-6A: ka; 20A-0A: 0kA 0.6A-2.5A: 2kA;.0A-6A: ka; 20A-0A: 0kA see above 6,000 on/off operations with 2xRC 25 C, +0, -5 (77 F, +0-9 ) /50g (.0 lb.) Top/Bottom: 8-3 AWG 2 Nm (7.7 lb.in.) / 2.5Nm (22.2 lb.in) 200V HP (HEA) 208V HP (HEA) V HP (HEA) 60-80V HP (HEA) Through MA2.5U, ampere rated for motor circuits having a fullload-amperage (FLA) not exceeding the MA s general purpose rated current (RC, equals maximum dial setting) and a locked rotor current not exceeding 6 times the MA s RC. /2 (.0) 3/ (3.2) 3/ (3.) (3.6) 2 (3.2) 3/ (5.6) /2 (6.0) /2 (5.7) /2 (5.2) 3 (.8) (7.2) 2 (7.8) 2 (7.5) 3 (9.6) 5 (7.6) 2 (3.6) 3 (.0) 3 (0.6) 5 (5.2) 0 (.0) 3 (9.2) 5 (7.5) 5 (6.7) 5 (5.2) 0 (.0) 3 (9.2) 5 (7.5) 7/2 (2.2) 7/2 (22.0) 5 (2.0) 5 (30.) 7/2 (25.0) 7/2 (2.2) 0 (28.0) 20 (27.0) 5 (30.) 0 (32.0) 0 (3.0) 0 (28.0) 25 (3.0) Note: HEA - Horsepower Equivalent Amperes, the nominal amperage assigned to standard motor horsepower ratings in design guide tables such as NFPA-70 Tables 30-28, 30-29, ; UL077 Table 6.2; CSA - C22.2 No. 235-M89 Tables and 5; CSA-C22.2 No. -M9 Table 9, etc. Multiply HEA values (in parenthesis) by. if power factor is 90%, and by.2 if power factor is 80%. a The standard-circuit short-circuit rating is ka for all types. Group ratings can be used in a standard circuit (e.g., MA.0U at 2kA), but a higher standard rating cannot be used in a group circuit (e.g., MA0U at ka only in standard circuit.) 8 Altech Corp. 35 Royal Road Flemington, NJ P F

49 Dimensions in mm 3.8 mm 37.5 mm 25.5 mm UL mm MA- Series Trip Curves 89.5 mm.5 mm 35 mm mm mm 3.8 mm 70. mm 5 mm ANNEX MA/USA Manual Motor Con trol ler Altech Corp. 35 Royal Road Flemington, NJ P F

50 UL 89 UM (V-EA) and MA Accessories For mounting instructions please refer to page 3. Auxiliary Contact, Alarm Switch C US UL Listed E37938 ANNEX * Not UL approved. Type/ Cat No. Description Contacts Type Std Pk H0UM Auxiliary Contact NO 6 HUM 2 Auxiliary Contacts NO + NC 6 H2UM 3 Auxiliary Contacts NO + 2NC 6 H2UM 3 Auxiliary Contacts 2NO + NC 6 HLSM* Auxiliary/ Signal Contacts CO + CO (Signal) 6 Rated Operating Currents Minimum Contact Load Torque Wire Range: Single Wire Stranded Wire Stranded Wire with Ferrule Shunt Trip 0A@20V AC 3A@0V DC A@220V DC 2V DC max. 0.8Nm (7 lb.in).0mm² - 2.5mm² (8- AWG).0mm² -.5mm² (8-6 AWG).0mm² -.5mm² (8-6 AWG) Max. Operating Type/ Cat No. Rated Voltage U N U N Std Pk FA2UM 2V AC/DC.3A 5 FA2UM 2V AC/DC 0.6A 5 FA8UM 8-72V AC/DC 0.2A 5 0V FA0UM 0-20V AC/DC, 20V 5 277V AC 277V Undervoltage Trip* Type/ Cat No. Line Voltage V E Std Pk UA20UM 20V AC, 60Hz 5 Reset-Hold Voltage = 0.85 x V E Drop-Out Voltage = 0.35 ~ 0.7 x V E V E = Rated Voltage ** UM (V-EA) and MA can also be locked in the on and off position by simply using a common lead or meter seal, which gets fed through the hole in the handle and a corresponding hole in the housing. 87 mm 52.7 mm 8.8 mm 2.8 mm 7.5 mm 9 mm 89.5 mm 7.7 mm 6 mm 88 mm 6 mm AWG 23 5 mm 3.6 mm 63.8 mm Dimensions HxxUM. 68. mm 3.8 mm 63.8 mm 2. mm 6 mm Dimensions HLSM. 68. mm Dimensions UA20UM. ca mm 5 mm 5 mm 50 Altech Corp. 35 Royal Road Flemington, NJ P F

51 UM (V-EA) and MA Accessories For mounting instructions please refer to page 3. C US UL Listed E37938 UL 89 Neutral Pole Type/ Cat No. Rated Current I N Rated Voltage U N Std Pk N63UM A 80Y/277V AC 6 Type/ Cat No. Type/ Cat No. 7.5 mm 89.3 mm.5 mm 3.5 mm mm 37.5 mm 25.5 mm 6 mm 7 mm 8 mm mm.5 mm Std Pk E mm mm 68. mm Dimensions N63UM, FAxxUM. Touch Protection Caps to cover the terminal screw holes on the switching devices, neutral Poles and shunt trips for increased touch protection. Std Pk BS.UL 00 Mounting Screw 3mm to connect the auxiliary contact and shunt trip or neutral Pole to the circuit breaker. 5 mm Cooling Spacer Type/ Cat No. Type/ Cat No. Std Pk / Lock-out Adapter** Std Pk EASS 0 ANNEX Altech Corp. 35 Royal Road Flemington, NJ P F

52 UL 89 ANNEX MS-Series Three Phase Adjustable Trip Economy Manual Motor Controllers with overload and short circuit protection, phase failure sensitivity according to IEC 97--, DIN VDE 0660 Part 02 C US E37938 Type Designation MS 06 (a) (b) (a) = MS - Manual Motor Controller (b) = Rated Current Maximum Voltage Short Circuit Withstanding Rating (UL/CSA Rating) Group Short Circuit Withstanding Rating (UL/CSA Rating) Interrupting Capacity (VDE - Ratings) Mechanical Endurance Standard Pack and Weight Terminal Size Acceptability Terminal Torque Dimensions With its high breaking capacity and current limitation the MS Manual Motor Controllers provide optimum protection for electrical motors as well as for other consumer units up to 25 amps. They are equipped with phase failure sensitivity, isolating and main switch functions. 3 ranges cover nominal rated currents from 0. up to 25 amps. The MS s are temperature compensated; the trip current of the magnetic part is 2 x ln. The Manual Motor Controllers are built in accordance with IEC 97. Type/ Rated Overload Instantaneous 3Ø Horsepower Rating Cat. No. Current release setting adjustment/fla (A) (A) 5V 200V 230V 80V 600V Ampere rated for motor circuits having MS a full-load-amperage (FLA) not MS exceeding the MS s general purpose MS rated current and a locked rotor current not exceeding 6 MS times the MS s rated MS current. /2hp /2hp MS /hp hp MS /2hp /2hp hp /2hp MS /2hp 3/hp hp 2hp 3hp MS /hp /2hp /2hp 3hp 5hp MS hp 2hp 3hp 5hp 7/2hp MS hp 3hp 5hp 0hp 0hp MS hp 5hp 7/2hp 5hp MS hp 5hp 7/2hp 5hp 30mm (.8 in.) 76.5mm (3.0 in.) 80mm (3.5 in.) 5mm (.77 in.) 600V AC (MS20 and MS25, 80V AC) 5kA 5kA A: Self protected 0-25A: 6kA 0,000 on/off operations /250g (0.55lb) -0 AWG.8Nm (6lb. in.) 5mm (.77 in.) 63mm (2.8 in.) 35.5mm (.0 in.) 2mm (.65 in.) 7.5mm (2.8 in.) 75.5mm (2.97 in.) 85.5mm (3.37 in.) 52 Altech Corp. 35 Royal Road Flemington, NJ P F

53 Accessories MS Three Phase Adjustable Trip Economy Auxiliary contact blocks for side mounting (3.5A/230V AC; 2A/00V AC) Manual Motor Controllers Width Contacts Type/ Weight Std. mm Cat. No. g/pc. Pk. UL NO HMS Busbar Insulated Enclosure IP55 with integrated PE(N) terminal; top and bottom each have 2 metric knock-outs Type/ Weight Std. Cat. No. g/pc. Pk. MS.G55 20 Flush Mounting Enclosure IP55 with integrated PE(N) terminal Type/ Weight Std. Cat. No. g/pc. Pk. MS.F55 70 Type/Cat. No. Busbar for for for for 63A 2 MS 3 MS MS 5 MS no spacing G5--2 G5--3 G5-- G5--5 with auxiliary switch (/2 pole) G5--2 G5--3 G5-- G5--5 spacing 9 NO + NC HMS NO HMS NC HMS NC HMS Emergency-Stop twist or key to release, red on yellow background Release Type/ Weight Std. Type Cat. No. g/pc. Pk. Twist MS.PV 60 5 Key MS.PS Indicator Light with neon bulb, nominal rated voltage: V or 380-0V Color Type/ Weight Std. Cat. No. g/pc. Pk V 380-0V trans MS.SLW2 MS.SLW3 0 5 green MS.SLG2 MS.SLG3 0 5 red MS.SLR2 MS.SLR3 0 5 yellow MS.SLJ2 MS.SLJ3 0 5 Power Feed Block Type/ Rating Std. Cat. No. (A) Pk. GE2-63A ANNEX Altech Corp. 35 Royal Road Flemington, NJ P F

54 UL 89 ANNEX UR Series UL077 Recognized Supplementary Protector DIN Rail Mounted 7.5mm width per pole Thermal Magnetic A / 80Y/277V AC, 50/60Hz 0kA Short Circuit Withstand Capacity Applications (on the load side of Branch Circuit Protection) include: Sensitive Electronics, Power Supplies, Appliance circuits, etc. UR - Series Voltage Rating Short Circuit Withstand Rating Calibration Temperature Ambient Temperature Storage Temperature Terminal Torque (min/max) Electrical Life Mechanical Life Vibration Resistance Resistance to mechanical shocks Degree of protection acc. IEC/EN Mounting Orientation A / 80Y/277V AC 0.5-0A (RC): 0 ka with no back-up fuse 8-63A (RC): 0 ka with UL-listed Class J back-up fuse; 5 ka with no back-up fuse 30ºC (86ºF) -25ºC to +55ºC (-3ºF to 3ºF ) -0ºC to +70ºC (-0ºF to 58ºF ) 2 Nm (7.7 lb.in.) / 2.5Nm (22.2 lb.in) 6,000 switching cycles ON/ OFF 0,000 switching cycles ON/ OFF > 5g according to DIN EN during a load with.05 x I N ms IP20 In any plane Short Circuit Withstand Ratings for R-Series Supplementary Protector Backup Protection Trip Amp UL-Listed No Backup Fuse Curve Range Class J Fuse Required up to 0kA up to: All 0.5-0A 70A 0kA All 2-60A xrc* 5kA *up to nearest rated current E Altech Corp. 35 Royal Road Flemington, NJ P F

55 Marking Details UL 89 Rated Current Trip Characteristic Approval Voltage Rating No. of Poles Individual Part Number is shown Short Circuit Withstand Rating Dimensions in mm Trip-Characteristics* Characteristic Trip Boundaries Thermal Trip Must not Trip>00ms 36.5 mm 36.8 mm Must Trip <hr 7.5 mm Application Overview Must not Must Trip Trip>00ms at 00ms B-Characteristics.3xRC.5xRC 3xRC 5xRC C-Characteristics.3xRC.5xRC 5xRC 0xRC D-Characteristics Magnetic Trip.3xRC.5xRC 0xRC 20xRC 35 mm 52.5 mm Pole 2 Pole 3 Pole Lighting Wiring Protection Control Circuits Business Equipment Appliances Applications Control Transformers *The value of each characteristic is shown vertically beneath its corresponding heading..5 mm Power Supplies 30.5 mm 68. mm General Electronics Reactive Load Warning! This information should only be used as a selection guide. The use of a Miniature Circuit Breaker/Supplementary Protector in an application with a certain Trip-Characteristic always requires prototype testing! It is the responsibility of the circuit design engineer to select the appropriate Miniature Circuit Breaker/Supplementary Protector for his specific application mm.5 mm 3.5 mm mm 37.5 mm 25.5 mm mm Circuit Diagram Product Series 5 mm ANNEX 55

56 UL 89 UR - Series B-Trip Characteristic Application Examples: Business equipment, wiring protection, lighting, appliances, control circuits, some motors and some electronic applications. Relatively long thermal trip delay but low magnetic trip point. C US UL Recognized E3795 One Pole Three Pole ANNEX Standard Pack: 2 0.3A - 32A.75kg (3.86 lb.) 0A - 63A 2.07kg (.56 lb.) Standard Pack: 6 0.3A - 32A.75kg (3.86 lb.) 0A - 63A 2.07kg (.56 lb.) Rated Type/ Rated Current Cat. No. Voltage 0.5A B05UR 277V AC.0A BUR 277V AC 2.0A B2UR 277V AC 3.0A B3UR 277V AC.0A BUR 277V AC 5.0A B5UR 277V AC 6.0A B6UR 277V AC 8.0A B8UR 277V AC 0A B0UR 277V AC 2A B2UR 277V AC 3A B3UR 277V AC 5A B5UR 277V AC 6A B6UR 277V AC 20A B20UR 277V AC 25A B25UR 277V AC 30A B30UR 277V AC 32A B32UR 277V AC 0A B0UR 277V AC 50A B50UR 277V AC 60A B60UR 277V AC 63A* B63UR 277V AC Two Pole Rated Type/ Rated Current Cat. No. Voltage 0.5A 2B05UR 80Y/277V AC.0A 2BUR 80Y/277V AC 2.0A 2B2UR 80Y/277V AC 3.0A 2B3UR 80Y/277V AC.0A 2BUR 80Y/277V AC 5.0A 2B5UR 80Y/277V AC 6.0A 2B6UR 80Y/277V AC 8.0A 2B8UR 80Y/277V AC 0A 2B0UR 80Y/277V AC 2A 2B2UR 80Y/277V AC 3A 2B3UR 80Y/277V AC 5A 2B5UR 80Y/277V AC 6A 2B6UR 80Y/277V AC 20A 2B20UR 80Y/277V AC 25A 2B25UR 80Y/277V AC 30A 2B30UR 80Y/277V AC 32A 2B32UR 80Y/277V AC 0A 2B0UR 80Y/277V AC 50A 2B50UR 80Y/277V AC 60A 2B60UR 80Y/277V AC 63A* 2B63UR 80Y/277V AC *63A is not UL Recognized. Standard Pack: 0.3A - 32A.75kg (3.86 lb.) 0A - 63A 2.07kg (.56 lb.) Rated Type/ Rated Current Cat. No. Voltage 0.5A 3B05UR 80Y/277V AC.0A 3BUR 80Y/277V AC 2.0A 3B2UR 80Y/277V AC 3.0A 3B3UR 80Y/277V AC.0A 3BUR 80Y/277V AC 5.0A 3B5UR 80Y/277V AC 6.0A 3B6UR 80Y/277V AC 8.0A 3B8UR 80Y/277V AC 0A 3B0UR 80Y/277V AC 2A 3B2UR 80Y/277V AC 3A 3B3UR 80Y/277V AC 5A 3B5UR 80Y/277V AC 6A 3B6UR 80Y/277V AC 20A 3B20UR 80Y/277V AC 25A 3B25UR 80Y/277V AC 30A 3B30UR 80Y/277V AC 32A 3B32UR 80Y/277V AC 0A 3B0UR 80Y/277V AC 50A 3B50UR 80Y/277V AC 60A 3B60UR 80Y/277V AC 63A* 3B63UR 80Y/277V AC Standard Dual Connection Terminal Box clamp terminals Top: 8-3 AWG; Bottom: 8-2 AWG (Line/Load reversible) Ring tongue terminals.3 mm (0. in.) Add-on Neutral Pole Rated Type/ Rated Current Cat. No. Voltage A N63UM 80/277V AC 8.3 mm (0.72 in.) Standard Pack: kg (.7) 5.3 mm (0.2 in.) Ring tongue max. 8-2 mm ( in.) M5 screw Box clamp * May differ by manufacturer. Top terminal ring tongue max. thickness.6mm. 56 Altech Corp. 35 Royal Road Flemington, NJ P F

57 UR - Series C-Trip Characteristic Application Examples: Low inrush motors, lighting, wiring protection, appliances, business equipment, and control circuit applications. Relatively long thermal trip delay and medium magnetic trip point. C US UL Recognized E3795 UL 89 One Pole Three Pole Standard Pack: 2 0.3A - 32A.75kg (3.86 lb.) 0A - 63A 2.07kg (.56 lb.) Standard Pack: 6 0.3A - 32A.75kg (3.86 lb.) 0A - 63A 2.07kg (.56 lb.) Rated Type/ Rated Current Cat. No. Voltage 0.5A C05UR 277V AC.0A CUR 277V AC 2.0A C2UR 277V AC 3.0A C3UR 277V AC.0A CUR 277V AC 5.0A C5UR 277V AC 6.0A C6UR 277V AC 8.0A C8UR 277V AC 0A C0UR 277V AC 2A C2UR 277V AC 3A C3UR 277V AC 5A C5UR 277V AC 6A C6UR 277V AC 20A C20UR 277V AC 25A C25UR 277V AC 30A C30UR 277V AC 32A C32UR 277V AC 0A C0UR 277V AC 50A C50UR 277V AC 60A C60UR 277V AC 63A* C63UR 277V AC Two Pole Rated Type/ Rated Current Cat. No. Voltage 0.5A 2C05UR 80Y/277V AC.0A 2CUR 80Y/277V AC 2.0A 2C2UR 80Y/277V AC 3.0A 2C3UR 80Y/277V AC.0A 2CUR 80Y/277V AC 5.0A 2C5UR 80Y/277V AC 6.0A 2C6UR 80Y/277V AC 8.0A 2C8UR 80Y/277V AC 0A 2C0UR 80Y/277V AC 2A 2C2UR 80Y/277V AC 3A 2C3UR 80Y/277V AC 5A 2C5UR 80Y/277V AC 6A 2C6UR 80Y/277V AC 20A 2C20UR 80Y/277V AC 25A 2C25UR 80Y/277V AC 30A 2C30UR 80Y/277V AC 32A 2C32UR 80Y/277V AC 0A 2C0UR 80Y/277V AC 50A 2C50UR 80Y/277V AC 60A 2C60UR 80Y/277V AC 63A* 2C63UR 80Y/277V AC *63A is not UL Recognized. Standard Pack: 0.3A - 32A.75kg (3.86 lb.) 0A - 63A 2.07kg (.56 lb.) Standard Dual Connection Terminal Box clamp terminals Top: 8-3 AWG; Bottom: 8-2 AWG (Line/Load reversible) Ring tongue terminals.3 mm (0. in.) 8.3 mm (0.72 in.) Rated Type/ Rated Current Cat. No. Voltage 0.5A 3C05UR 80Y/277V AC.0A 3CUR 80Y/277V AC 2.0A 3C2UR 80Y/277V AC 3.0A 3C3UR 80Y/277V AC.0A 3CUR 80Y/277V AC 5.0A 3C5UR 80Y/277V AC 6.0A 3C6UR 80Y/277V AC 8.0A 3C8UR 80Y/277V AC 0A 3C0UR 80Y/277V AC 2A 3C2UR 80Y/277V AC 3A 3C3UR 80Y/277V AC 5A 3C5UR 80Y/277V AC 6A 3C6UR 80Y/277V AC 20A 3C20UR 80Y/277V AC 25A 3C25UR 80Y/277V AC 30A 3C30UR 80Y/277V AC 32A 3C32UR 80Y/277V AC 0A 3C0UR 80Y/277V AC 50A 3C50UR 80Y/277V AC 60A 3C60UR 80Y/277V AC 63A* 3C63UR 80Y/277V AC Add-on Neutral Pole Rated Type/ Rated Current Cat. No. Voltage A N63UM 80/277V AC Standard Pack: kg (.7) 5.3 mm (0.2 in.) Ring tongue max. 8-2 mm ( in.) M5 screw Box clamp * May differ by manufacturer. Top terminal ring tongue max. thickness.6mm. ANNEX 57

58 UL 89 UR - Series D-Trip Characteristic Application Examples: Control transformers, power supplies, reactive loads. Relatively long thermal trip delay and very high magnetic trip point. C US UL Recognized E3795 One Pole Three Pole ANNEX Standard Pack: 2 0.3A - 32A.75kg (3.86 lb.) 0A - 63A 2.07kg (.56 lb.) Standard Pack: 6 0.3A - 32A.75kg (3.86 lb.) 0A - 63A 2.07kg (.56 lb.) Rated Type/ Rated Current Cat. No. Voltage 0.5A D05UR 277V AC.0A DUR 277V AC 2.0A D2UR 277V AC 3.0A D3UR 277V AC.0A DUR 277V AC 5.0A D5UR 277V AC 6.0A D6UR 277V AC 8.0A D8UR 277V AC 0A D0UR 277V AC 2A D2UR 277V AC 3A D3UR 277V AC 5A D5UR 277V AC 6A D6UR 277V AC 20A D20UR 277V AC 25A D25UR 277V AC 30A D30UR 277V AC 32A D32UR 277V AC 0A D0UR 277V AC 50A D50UR 277V AC 60A D60UR 277V AC 63A* D63UR 277V AC Two Pole Rated Type/ Rated Current Cat. No. Voltage 0.5A 2D05UR 80Y/277V AC.0A 2DUR 80Y/277V AC 2.0A 2D2UR 80Y/277V AC 3.0A 2D3UR 80Y/277V AC.0A 2DUR 80Y/277V AC 5.0A 2D5UR 80Y/277V AC 6.0A 2D6UR 80Y/277V AC 8.0A 2D8UR 80Y/277V AC 0A 2D0UR 80Y/277V AC 2A 2D2UR 80Y/277V AC 3A 2D3UR 80Y/277V AC 5A 2D5UR 80Y/277V AC 6A 2D6UR 80Y/277V AC 20A 2D20UR 80Y/277V AC 25A 2D25UR 80Y/277V AC 30A 2D30UR 80Y/277V AC 32A 2D32UR 80Y/277V AC 0A 2D0UR 80Y/277V AC 50A 2D50UR 80Y/277V AC 60A 2D60UR 80Y/277V AC 63A* 2D63UR 80Y/277V AC *63A is not UL Recognized. Standard Pack: 0.3A - 32A.75kg (3.86 lb.) 0A - 63A 2.07kg (.56 lb.) Rated Type/ Rated Current Cat. No. Voltage 0.5A 3D05UR 80Y/277V AC.0A 3DUR 80Y/277V AC 2.0A 3D2UR 80Y/277V AC 3.0A 3D3UR 80Y/277V AC.0A 3DUR 80Y/277V AC 5.0A 3D5UR 80Y/277V AC 6.0A 3D6UR 80Y/277V AC 8.0A 3D8UR 80Y/277V AC 0A 3D0UR 80Y/277V AC 2A 3D2UR 80Y/277V AC 3A 3D3UR 80Y/277V AC 5A 3D5UR 80Y/277V AC 6A 3D6UR 80Y/277V AC 20A 3D20UR 80Y/277V AC 25A 3D25UR 80Y/277V AC 30A 3D30UR 80Y/277V AC 32A 3D32UR 80Y/277V AC 0A 3D0UR 80Y/277V AC 50A 3D50UR 80Y/277V AC 60A 3D60UR 80Y/277V AC 63A* 3D63UR 80Y/277V AC Standard Dual Connection Terminal Box clamp terminals Top: 8-3 AWG; Bottom: 8-2 AWG (Line/Load reversible) Ring tongue terminals.3 mm (0. in.) 8.3 mm (0.72 in.) Add-on Neutral Pole Rated Type/ Rated Current Cat. No. Voltage A N63UM 80/277V AC Standard Pack: kg (.7) 5.3 mm (0.2 in.) Ring tongue max. 8-2 mm ( in.) M5 screw Box clamp * May differ by manufacturer. Top terminal ring tongue max. thickness.6mm. 58 Altech Corp. 35 Royal Road Flemington, NJ P F

59 * Not UL approved. UR Series Accessories For mounting instructions please refer to page 3. Auxiliary Contact, Alarm Switch Type/ Cat No. Description Contacts Type Std Pk H0UM Auxiliary Contact NO 6 HUM 2 Auxiliary Contacts NO + NC 6 H2UM 3 Auxiliary Contacts NO + 2NC 6 H2UM 3 Auxiliary Contacts 2NO + NC 6 HLSM* Auxiliary/ CO + CO (Signal) 6 Signal Contacts Rated Operating Currents Minimum Contact Load Torque Wire Range: Single Wire Stranded Wire Stranded Wire with Ferrule Shunt Trip 0A@20V AC 3A@0V DC A@220V DC 2V DC max. 0.8Nm (7 lb.in).0mm² - 2.5mm² (8- AWG).0mm² -.5mm² (8-6 AWG).0mm² -.5mm² (8-6 AWG) Max. Operating Type/ Cat No. Rated Voltage U N U N Std Pk FA2UM 2V AC/DC.3A 5 FA2UM 2V AC/DC 0.6A 5 FA8UM 8-72V AC/DC 0.2A 5 0V FA0UM 0-20 V AC/DC, 20V 5 277V AC 277V Undervoltage Trip* Type/ Cat No. Line Voltage V E Std Pk UA20UM 20V AC, 60Hz 5 Reset-Hold Voltage = 0.85 x V E Drop-Out Voltage = 0.35 ~ 0.7 x V E V E = Rated Voltage Neutral Pole UL Listed E37938 Type/ Cat No. Rated Current I N Rated Voltage U N Std Pk N63UM A 80Y/277V AC 6 Touch Protection Caps to cover the terminal screw holes on the switching devices, neutral Poles and shunt trips for increased touch protection. Type/ Cat No. Type/ Cat No. Std Pk BS.UL 00 Mounting Screw 3mm to connect the auxiliary contact and shunt trip or neutral Pole to the circuit breaker. Std Pk E Cooling Spacer C Type/ Cat No. Type/ Cat No. US Std Pk / Lock-out Adapter** Std Pk EASS 0 ** UR series can also be locked in the on and off position by simply using a common lead or meter seal, which gets fed through the hole in the handle and a corresponding hole in the housing. 87 mm 52.7 mm 7.5 mm 8.8 mm 2.8 mm 7.5 mm 89.3 mm 7.7 mm 6 mm 9 mm 89.5 mm.5 mm 88 mm 6 mm 3.5 mm AWG 23 5 mm 63.8 mm Dimensions HxxUM. mm 37.5 mm 25.5 mm 3.6 mm 6 mm 7 mm 8 mm mm.5 mm 30.5 mm mm 68. mm 3.8 mm 63.8 mm 2. mm 6 mm Dimensions HLSM. 68. mm Dimensions UA20UM. 68. mm ca Dimensions N63UM, FAxxUM. 5 mm 5 mm 5 mm 5 mm UL 89 ANNEX 59

60 UL 89 ANNEX UR Series Trip Curves B Trip Curve C Trip Curve D Trip Curve Tripping time t Seconds Minutes Tripping time t Seconds Minutes.3-.5xI N x x0-3 Thermal Overload Must Trip < hr = 5% RC Must Not Trip > hr = 3% RC xI N x x0-3 Multiple of Rated Current 0.5A Through 0A Rated Current Thermal Overload Must Trip < hr = 5% RC Must Not Trip > hr = 3% RC Multiple of Rated Current 2A Through 63A Rated Current B Magnetic Trip Parameters Rated current 0.5A to 63A.. Hold for a minimum of 00ms at surge of 3 times rated current. 2. Trip in under 00ms at 5 times rated current. Tripping time t Seconds Minutes Tripping time t Seconds Minutes UR Series Internal Resistance.3-.5xI N x x0-3 Thermal Overload Must Trip < hr = 5% RC Must Not Trip > hr = 3% RC x x0-3 Multiple of Rated Current 0.5A Through 0A Rated Current.3-.5xI N 60 0 Thermal Overload Must Trip < hr = 5% RC Must Not Trip > hr = 3% RC Multiple of Rated Current 2A Through 63A Rated Current C Magnetic Trip Parameters Rated current 0.5A to 63A.. Hold for a minimum of 00ms at surge of 5 times rated current. 2. Trip in under 00ms at 0 times rated current. Tripping time t Seconds Minutes Tripping time t Seconds Minutes.3-.5xI N x x0-3 Thermal Overload Must Trip < hr = 5% RC Must Not Trip > hr = 3% RC Multiple of Rated Current x x A Through 0A Rated Current.3-.5xI N 60 0 Thermal Overload Must Trip < hr = 5% RC Must Not Trip > hr = 3% RC Multiple of Rated Current 2A Through 63A Rated Current D Magnetic Trip Parameters Rated current 0.5A to 63A.. Hold for a minimum of 00ms at surge of 0 times rated current. 2. Trip in under 00ms at 6 times rated current. Rated Current Trip Characteristic (A) B C D (Ohm) (Ohm) (Ohm) / / / / 63* Altech Corp. 35 Royal Road Flemington, NJ P F

61 Temperature Correction Curve (UL, DL, V-EA, MA and UR series) Rated Current (%) % Cooling spacer (Part #5.960) between each group of 3 poles will eliminate these adjustments Calibration Temperature Ambient Temperature up to 3 poles adjacent mounted maximum 20% off RC for a total off 0 poles or more, adjacent mounted* 0 0 Ambient Temperature Adjustment 5% of RC for every 0 C (8 F). Adjacent Mounting Temperature Adjustment 3% of RC for every additional pole above 3. Maximum 20% off RC for a total of 0 poles or more.* Accessory Mounting Instructions (UL, V-EA and UR series) Neutral / Shunt Trip + Auxiliary Contact Ambient Temperature and Adjacent Mounting/ Loading Adjustment Ambient Temperature 25 C to 55 C, Storage Temperature - 0 C to 70 C 90 ( C) 9 ( F) Neutral Poles N63UM, N32UL, N63UL or Shunt Trips FA..UM, FA..UL can be mounted on the right or left side of the circuit protection device.. Turn handle to off position. 2. Remove gray cover from the circuit protection device and accessory. 3. Insert linkage component between circuit protection device and neutral pole (N63UM, N32UL, N63UL) or shunt trip (FA..UM, FA..UL).. Insert connecting pin into handle. 5. Assemble circuit protection device and neutral pole (N63UM, N32UL, N63UL) or shunt trip (FA..UM, FL..UL). 6. The auxiliary contact (H..UM, H..UL) can also be mounted on the right side by using a different screw (E9839; see accessory pages, 32 or ). After final assembly check operation by moving the handle to the ON/OFF position several times. Auxiliary Contact. 2 mm. Switching Device Neutral Switch/ Shunt Trip 7mm Auxiliary Contact. Switching Device 90 Neutral Switch/ Shunt Trip Auxiliary Contact Auxiliary contact can be mounted on the right side of the circuit protection device only.. Turn handles to OFF position. 2. Remove gray cover from switching device. 3. Combine circuit protection device and auxiliary contact (H...UM, H...UL).. Insert mounting screws and connect the two devices by turning the screws 90 clockwise. After final assembly check operation by moving the handle to the ON/OFF position several times Mounting screw 3mm UL 89 ANNEX 6

62 UL 89 ANNEX R-Series UL077 Recognized Supplementary Protector DIN Rail Mounted 7.5mm width per pole Thermal Magnetic 80Y/277V AC, 50/60Hz 0kA Short Circuit Withstand Capacity Positive Trip indicator (Green - off/tripped, Red - on) Applications (on the load side of Branch Circuit Protection) include: Sensitive Electronics, Power Supplies, Appliance circuits, etc. Voltage Rating Short Circuit Withstand Rating (UL - Ratings) Interrupting Capacity (IEC/EN60898/6097-2) Calibration Temperature Operating Temperature Storage Temperature Terminal Size Acceptability and Torque Terminal Protection Degree Electrical Life Mechanical Life Wire Connection Vibration Resistance Mounting Orientation 80Y/277VAC 0.5-6A (RC): 0kA with no back-up fuse 8-63A (RC): 0kA with UL-listed Class J back-up fuse; 5kA with no back-up fuse A (RC): 0kA 30 C (86 F) -25 to 60 C (-3 to 0 F) -25 to 75 C (-3 to 67 F) -3 AWG: 7.5 lb-in. (2.0 Nm) 8-6 AWG: 25 lb-in. (2.8 Nm) IP20 at front 6,000 cycles on/off 0,000 cycles on/off copper wire only 60/75 C 3g (8-50Hz) In any plane short CirCuit WithstanD ratings for r-series supplementary protector Backup Protection Trip Amp UL-Listed No Backup Fuse Curve Range Class J Fuse Required up to 0kA up to: All 0.5-6A xrc* 0kA All 8-63A xrc* 5kA *up to nearest rated current DC voltage rating: 8 VDC (self-certified). E306 Indicator window Trip curve and amperage window display. ON OFF 62 Altech Corp. 35 Royal Road Flemington, NJ P F

63 Seconds Time t Minutes x x B C D Multiple of Rated Current Time versus Current Trip Curve 96. (3.80 in.) 85.5 (3.37 in.) 6.5 (0.26 in.) (.73 in.) 60 (2.36 in.) 77 (3.03 in.) 7.5 (0.69 in.) 35 (.38 in.) 52.5 (2.07 in.) Trip-Characteristics* Characteristic Trip Boundaries Thermal Trip Must not Trip>00ms Must Trip <hr B-Characteristics.3xRC.5xRC 3xRC 5xRC C-Characteristics D-Characteristics Magnetic Trip Must not Trip>00ms Must Trip at 00ms.3xRC.5xRC 5xRC 0xRC.3xRC.5xRC 0xRC 20xRC For the exact trip curve, please refer to page 67. Lighting Business Wiring Equipment Protection Control Appliances Circuits Dimensions in mm side view POlE 2 POlE 3 POlE Applications Control Transformers Power Supplies *The value of each characteristic is shown vertically beneath its corresponding heading. General Electronics Reactive Load 5 (.77 in.) Warning! This information should only be used as a selection guide. The use of a Miniature Circuit Breaker/Supplementary Protector in an application with a certain Trip-Characteristic always requires prototype testing! It is the responsibility of the circuit design engineer to select the appropriate Miniature Circuit Breaker/Supplementary Protector for his specific application. UL 89 ANNEX Altech Corp. 35 Royal Road Flemington, NJ P F

64 UL 89 B-Trip Characteristic Application Examples: Business equipment, wiring protection, lighting, appliances, control circuits and some electronic applications. Relatively long thermal trip delay but low magnetic trip point. E306 ANNEX One Pole Three Pole Rated Type/ Current Cat. No. 0.5A BU05R.0A BUR 2.0A BU2R 3.0A BU3R.0A BUR 5.0A BU5R 6.0A BU6R 8.0A BU8R 0A BU0R 2A BU2R 3A BU3R 5A BU5R 6A BU6R 20A BU20R 25A BU25R 30A BU30R 32A BU32R 0A BU0R 50A BU50R 60A BU60R 63A BU63R Standard Pack: 2 0.5A - 63A:.6kg (3.5 lb.) Rated Type/ Current Cat. No. 0.5A 3BU05R.0A 3BUR 2.0A 3BU2R 3.0A 3BU3R.0A 3BUR 5.0A 3BU5R 6.0A 3BU6R 8.0A 3BU8R 0A 3BU0R 2A 3BU2R 3A 3BU3R 5A 3BU5R 6A 3BU6R 20A 3BU20R 25A 3BU25R 30A 3BU30R 32A 3BU32R 0A 3BU0R 50A 3BU50R 60A 3BU60R 63A 3BU63R Standard Pack: 0.5A - 63A:.66kg (3.67 lb.) Two Pole Rated Type/ Current Cat. No. 0.5A 2BU05R.0A 2BUR 2.0A 2BU2R 3.0A 2BU3R.0A 2BUR 5.0A 2BU5R 6.0A 2BU6R 8.0A 2BU8R 0A 2BU0R 2A 2BU2R 3A 2BU3R 5A 2BU5R 6A 2BU6R 20A 2BU20R 25A 2BU25R 30A 2BU30R 32A 2BU32R 0A 2BU0R 50A 2BU50R 60A 2BU60R 63A 2BU63R Standard Pack: 6 0.5A - 63A:.6kg (3.5 lb.) Four Pole Please contact Altech. Non-standard current ratings available. Minimum quantities may apply. Please contact Altech for further details. 6 Altech Corp. 35 Royal Road Flemington, NJ P F

65 C-Trip Characteristic Application Examples: Lighting, wiring protection, appliances, business equipment, and control circuit applications. Relatively long thermal trip delay and medium magnetic trip point. E306 UL 89 One Pole Three Pole Rated Type/ Current Cat. No. 0.5A CU05R.0A CUR 2.0A CU2R 3.0A CU3R.0A CUR 5.0A CU5R 6.0A CU6R 8.0A CU8R 0A CU0R 2A CU2R 3A CU3R 5A CU5R 6A CU6R 20A CU20R 25A CU25R 30A CU30R 32A CU32R 0A CU0R 50A CU50R 60A CU60R 63A CU63R Standard Pack: 2 0.5A - 63A:.6kg (3.5 lb.) Rated Type/ Current Cat. No. 0.5A 3CU05R.0A 3CUR 2.0A 3CU2R 3.0A 3CU3R.0A 3CUR 5.0A 3CU5R 6.0A 3CU6R 8.0A 3CU8R 0A 3CU0R 2A 3CU2R 3A 3CU3R 5A 3CU5R 6A 3CU6R 20A 3CU20R 25A 3CU25R 30A 3CU30R 32A 3CU32R 0A 3CU0R 50A 3CU50R 60A 3CU60R 63A 3CU63R Standard Pack: 0.5A - 63A:.66kg (3.67 lb.) Two Pole Rated Type/ Current Cat. No. 0.5A 2CU05R.0A 2CUR 2.0A 2CU2R 3.0A 2CU3R.0A 2CUR 5.0A 2CU5R 6.0A 2CU6R 8.0A 2CU8R 0A 2CU0R 2A 2CU2R 3A 2CU3R 5A 2CU5R 6A 2CU6R 20A 2CU20R 25A 2CU25R 30A 2CU30R 32A 2CU32R 0A 2CU0R 50A 2CU50R 60A 2CU60R 63A 2CU63R Standard Pack: 6 0.5A - 63A:.6kg (3.5 lb.) Four Pole Please contact Altech. Non-standard current ratings available. Minimum quantities may apply. Please contact Altech for further details. ANNEX Altech Corp. 35 Royal Road Flemington, NJ P F

66 UL 89 D-Trip Characteristic Application Examples: Control transformers, power supplies and reactive loads. Relatively long thermal trip delay and very high magnetic trip point. E306 ANNEX One Pole Three Pole Rated Type/ Current Cat. No. 0.5A DU05R.0A DUR 2.0A DU2R 3.0A DU3R.0A DUR 5.0A DU5R 6.0A DU6R 8.0A DU8R 0A DU0R 2A DU2R 3A DU3R 5A DU5R 6A DU6R 20A DU20R 25A DU25R 30A DU30R 32A DU32R 0A DU0R 50A DU50R 60A DU60R 63A DU63R Standard Pack: 2 0.5A - 63A:.6kg (3.5 lb.) Rated Type/ Current Cat. No. 0.5A 3DU05R.0A 3DUR 2.0A 3DU2R 3.0A 3DU3R.0A 3DUR 5.0A 3DU5R 6.0A 3DU6R 8.0A 3DU8R 0A 3DU0R 2A 3DU2R 3A 3DU3R 5A 3DU5R 6A 3DU6R 20A 3DU20R 25A 3DU25R 30A 3DU30R 32A 3DU32R 0A 3DU0R 50A 3DU50R 60A 3DU60R 63A 3DU63R Standard Pack: 0.5A - 63A:.66kg (3.67 lb.) Two Pole Rated Type/ Current Cat. No. 0.5A 2DU05R.0A 2DUR 2.0A 2DU2R 3.0A 2DU3R.0A 2DUR 5.0A 2DU5R 6.0A 2DU6R 8.0A 2DU8R 0A 2DU0R 2A 2DU2R 3A 2DU3R 5A 2DU5R 6A 2DU6R 20A 2DU20R 25A 2DU25R 30A 2DU30R 32A 2DU32R 0A 2DU0R 50A 2DU50R 60A 2DU60R 63A 2DU63R Standard Pack: 6 0.5A - 63A:.6kg (3.5 lb.) Four Pole Please contact Altech. Non-standard current ratings available. Minimum quantities may apply. Please contact Altech for further details. 66 Altech Corp. 35 Royal Road Flemington, NJ P F

67 R-Series Trip Curves B, C and D Trip Less than 0A Tripping time t Seconds Minutes Rated current of MCB.3.5 B, C and D Trip 0A and higher B C D 0.05 B C D Multiple of Rated Current Temperature and Power Loss Specifications I n (A) Internal Impedances & Power Loss Internal impedance Power loss on CB Maximum allowable impedance of breakdown loop (0.2/0.s) Tripping time t Seconds Minutes Multiple of Rated Current MCB Temperature Compensation Effective rated current allowing for ambient temperature. Z (m Ω) P (W) Z s ( Ω) I cor (A) Char. B,C,D Char. Ambient Temperature B,C,D Char.B Char.C Char.D -20 C -0 C 0 C 0 C 20 C 30 C 0 C 50 C 60 C UL 89 ANNEX Altech Corp. 35 Royal Road Flemington, NJ P F

68 UL 89 Accessories R-Series Supplementary Protector Accessories can be factory or field mount ed on R-Series supplementary protectors for enhanced control and mon i tor ing capabilities. Field mounting kits include all necessary parts and in struc - tions. Accessories can be gang mount ed on a single controller (the Auxiliary Switch in the outside position). The mounting arrange ment links the internal latch-pins for the tripping mechanisms, ensur ing si mul ta neous trips. Handles are linked to simplify manual resetting. E306 ANNEX Shunt Trip Undervoltage Trip Neutral Pole (63A/80Y/277 VAC) Description Type/ Cable Cable Torque Torque Cat. No. Max Min Max Min Neutral ALTN2 25mm 2 2.5mm 2 2Nm.5Nm AWG 3 Standard Pack: 0 AWG lb-in 2 lb-in.25kg (2.77 lb.) Shunt Trip and Undervoltage Trip Description Shunt Trip Operational Rated Undervoltage Trip* Type/Cat. No. Voltage Coil Current Type/Cat. No. AC Coil: 2V AC FA2ACR V 6A UV2ACR 2V AC FA2ACR V 2.8A UV2ACR 8V AC FA8ACR V 0.8A UV8ACR 60V AC FA60ACR 2-66V ~0.7A UV60ACR 0V AC FA0ACR 77-2V 0.5A UV0ACR 20V AC FA20ACR 8-32V ~0.5A UV20ACR 230V AC FA230ACR 6-253V 0.6A UV230ACR 277V AC FA277ACR 9-305V ~0.5A UV277ACR 00V AC FA00ACR 280-0V 0.5A UV00ACR DC Coil: 2V DC FA2DCR V ~6A UV2DCR 2V DC FA2DCR V 3A UV2DCR 8V DC FA8DCR V 2A UV8DCR 0V DC FA0DCR 77-2V 0.6A UV0DCR * Reset-Hold Voltage = 0.85 x V E ; Drop-Out Voltage = 0.2 x V E Standard Pack: 0.kg (2.3 lb.) Terminal Size - min/max Terminal Torque - min/max 2.5 mm 2 (2 AWG) / 25mm 2 (3 AWG).5 Nm (2 lb. in.) / 2 Nm (7.5 lb. in.) 68 Altech Corp. 35 Royal Road Flemington, NJ P F

69 UL 89 Auxiliary Contact Description Type/ Cable Cable Torque Torque Cat. No. Max Min Max Min x CO HCOR 2 x CO H2COR x CO, Signal HSTCOR & Test Button Standard Pack: 5 HCOR: 0.5kg (.32 lb.); H2COR, HSTCOR: 0.72kg (.59 lb.) Wiring Diagram Auxiliary Switch 2 Lock-out Adapter Description Yellow HCOR Standard Pack: 0 50g (.76 oz.) (A/230 VAC) Supplementary Protector > Type/ Cat. No. EASS2 95 luggage lock H2COR Auxiliary Switch 2.5mm 2 0.5mm 2 0.5Nm 0.33Nm AWG 2 AWG 20 lb-in 3 lb-in 2 Supplementary Protector > 2 Signal Switch HSTCOR Regular Auxiliary Switch 2 Supplementary Protector > 2 ANNEX Altech Corp. 35 Royal Road Flemington, NJ P F

70 UL 89 Altech UL077/508 Busbar System Without Altech Busbar System UL508 listed E2052 ANNEX UL077/508 Listed Busbars The Altech Busbar System is an innovative way to jumper up to 57 poles of Manual Motor Controllers (MMC) and Supplementary Protectors (SP). The advantages of this busbar system are: 30% Installation time savings Panel space savings Reduced maintenance High electrical ratings UL077/508 Busbar System With Altech Busbar System Universal UL077/508 Busbar fits most Supplementary Protectors and Manual Motor Controllers in the market! Please contact Altech for details and further information. -57 different pin configurations /2 pole spacing (auxiliary switch) available Power Feeding: Power Feed Lugs (5A), Direct Power Feed (5A), Power Feed Block (200A) UL recognized and listed for Altech s R-Series, ABL s UR, V-EA and MA Series of Manual Motor Controllers and Supplementary Protectors UL recognized and listed for use with most popular UL077 supplementary protectors and UL508 Manual Motor Controllers in the market. Customers can cut the Busbar without losing the UL approval Line/Load reversible Technical Specifications Busbars UL077/ 508 Material of Busbar Copper Material of Insulation (Housing) Polyamide Electrical Ratings 8mm 2 : 80A/600V AC/DC* 25mm 2 : 00A/600V AC/DC* Short Circuit Withstand Rating 0kA Applying Standards UL508, VDE0660 Part 00 and 502, VDE 0606, VDE 0659 * 000VDC ratings can be achieved by using all poles at the same voltage and polarity. 70 Altech Corp. 35 Royal Road Flemington, NJ P F

71 Altech UL077/508 Busbar System Power Feed Methods UL 89 ) Start/ End Feed Method P50UT* / P50UB* 80A/00A per phase 2 3 (P50UT) With the P50UT Power Feed Lug or the P50UB Modular Direct Power Feed as a Start/End Feeding Device a maximum input current of 80A/00A per Phase can be achieved. 80A with 8mm² Busbar and 00A with 25mm² Busbar. 2) Center/ Middle Feed Method P50UT* / P50UB* With the P50UT Power Feed Lug or the P50UB Modular Direct Power Feed as a Center/Middle Feeding Device a maximum input current of 5A per Phase can be achieved. (8mm²: 80A + 35A; 25mm²: 00A + 5A) P95UB* With the P95UB Power Feed Block as a Center/Middle Feeding Device a maximum input current of 60A/200A per Phase can be achieved (60A with 8mm² Busbar and 200A with 25mm² Busbar). Note: The Power Feed Block can only be used with a standard spacing 3 Phase UL077/508 Busbar A/00A per phase 35A/5A 35A/5A 35A/5A 35A/5A 35A/5A 35A/5A 80/00A 80/00A 80/00A * For complete specifications and description of Feeding Devices see page A/00A 80A/00A80A/00A 80A/00A 80A/00A80A/00A (P50UB) 5A per phase A per phase A/200A per phase (P50UT) 80A/00A 80A/00A 80A/00A 80A/00A 80A/00A 80A/00A (P50UB) 80/00A 80/00A 80/00A (P95UB) ANNEX Altech Corp. 35 Royal Road Flemington, NJ P F

72 UL 89 PHASE BUSBAR - standard spacing 8mm 2 for 80A UL508 listed E mm 5.5 mm x7.8 = 95.8 mm 8mm².5 mm 5.9 mm 25mm² 2 mm 5.9 mm 5.8 mm 7.6 mm 5.8 mm 7.6 mm ANNEX 8mm 2 for 80A* Type/ No. of Length Cat. No. Pins [mm] P8U/ P8U/3 3 5 P8U/ 79 P8U/ P8U/ P8U/ P8U/8 8 0 P8U/ P8U/ P8U/ 95 P8U/ P8U/ P8U/ 28 P8U/ P8U/ P8U/ P8U/ P8U/ P8U/ P8U/ P8U/ P8U/ P8U/ P8U/ P8U/ P8U/ P8U/ P8U/ ACCESSORIES 22 mm 8mm 2 for 80A* Type/ No. of Length Cat. No. Pins [mm] P8U/ P8U/ P8U/ P8U/ P8U/ P8U/ P8U/ P8U/ P8U/ P8U/ P8U/ P8U/ 728 P8U/ P8U/ P8U/ 782 P8U/ P8U/ P8U/ P8U/ P8U/ P8U/ P8U/ P8U/ P8U/ P8U/ P8U/ P8U/ P8U/ Type/Cat. No: P50UT-LP P50UB BRB5W 8/25CAPP Description: Power Feed Lug Modular Direct Power Feed Insulation Cap End Cap * 25mm 2 version for 00A available upon request. shown: P8U/2 72 Altech Corp. 35 Royal Road Flemington, NJ P F

73 PHASE BUSBAR - /2 pole spacing 8mm 2 for 80A UL 89 UL508 listed E mm 3.5 mm x27 = 297 mm.5 mm 8mm² 5.9 mm 2 mm 25mm² 5.9 mm 5.8 mm 7.6 mm 5.8 mm 7.6 mm 8mm 2 for 80A* Type/ No. of Length Cat. No. Pins [mm] P8UH/2 2 0 P8UH/ P8UH/ 95 P8UH/ P8UH/ P8UH/ P8UH/ P8UH/ P8UH/ P8UH/ 28 P8UH/ P8UH/ P8UH/ 365 P8UH/ P8UH/ P8UH/7 7 6 P8UH/8 8 7 P8UH/ ACCESSORIES 36 mm 8mm 2 for 80A* Type/ No. of Length Cat. No. Pins [mm] P8UH/ P8UH/ P8UH/ P8UH/ P8UH/ P8UH/ P8UH/ P8UH/ P8UH/ P8UH/ P8UH/ P8UH/ P8UH/ P8UH/ P8UH/ P8UH/ P8UH/ Type/Cat. No: P50UT-LP P50UB BRB5W 8/25CAPP Description: Power Feed Lug Modular Direct Power Feed Insulation Cap End Cap * 25mm 2 version for 00A available upon request. shown: P8UH/2 ANNEX Altech Corp. 35 Royal Road Flemington, NJ P F

74 UL 89 2 PHASE BUSBAR - standard spacing 8mm 2 for 80A / 25mm 2 for 00A 7.8 mm 6 mm x7.8 = 95.8 mm.5 mm 8mm² 2 mm 25mm² UL508 listed E mm 36.5 mm 2 mm 36.5 mm 2.6 mm 2.6 mm ANNEX 8mm 2 for 80A Type/ No. of Length Cat. No. Pins [mm] 2P8U3/ 69 2P8U3/ P8U3/ P8U3/ P8U3/ P8U3/ 29 2P8U3/ P8U3/ P8U3/ P8U3/ P8U3/ P8U3/ P8U3/ P8U3/ P8U3/ P8U3/ P8U3/ P8U3/ P8U3/ P8U3/ P8U3/ 782 2P8U3/ P8U3/ P8U3/ P8U3/ P8U3/ P8U3/ ACCESSORIES 2 mm 25mm 2 for 00A shown: 2P8U3/2 Type/ No. of Length Cat. No. Pins [mm] 2P25U3/ 69 2P25U3/ P25U3/ P25U3/ P25U3/ P25U3/ 29 2P25U3/ P25U3/ P25U3/ P25U3/ P25U3/ P25U3/ P25U3/ P25U3/ P25U3/ P25U3/ P25U3/ P25U3/ P25U3/ P25U3/ P25U3/ 782 2P25U3/ P25U3/ P25U3/ P25U3/ P25U3/ P25U3/ Type/Cat. No: P50UT P50UB BRB5W 8/25CAP3P Description: Power Feed Lug Modular Direct Power Feed Insulation Cap End Cap 7 Altech Corp. 35 Royal Road Flemington, NJ P F

75 2 PHASE BUSBAR - /2 pole spacing 8mm 2 for 80A / 25mm 2 for 00A UL 89 UL508 listed E mm 6 mm.5 mm 5x.5 = mm 8mm².5 mm 2 mm 36.5 mm 25mm² 2 mm 2 mm 36.5 mm 2.6 mm 2.6 mm 8mm 2 for 80A Type/ No. of Length Cat. No. Pins [mm] 2P8U3H/ 78 2P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ 302 2P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ 968 2P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ ACCESSORIES mm 25mm 2 for 00A shown: 2P8U3H/2 Type/ No. of Length Cat. No. Pins [mm] 2P25U3H/ 78 2P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ 302 2P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ 968 2P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ Type/Cat. No: P50UT P50UB BRB5W 8/25CAP3P Description: Power Feed Lug Modular Direct Power Feed Insulation Cap End Cap ANNEX Altech Corp. 35 Royal Road Flemington, NJ P F

76 UL 89 3 PHASE BUSBAR - standard spacing 8mm 2 for 80A / 25mm 2 for 00A UL508 listed E mm 6 mm x7.8 = 95.8 mm 8mm².5 mm 2 mm 36.5 mm 25mm² 2 mm 2 mm 36.5 mm 2.6 mm 2.6 mm ANNEX 8mm 2 for 80A Type/ No. of Length Cat. No. Pins [mm] 3P8U3/ P8U3/ P8U3/ P8U3/ P8U3/ P8U3/ P8U3/ P8U3/ P8U3/ P8U3/ P8U3/ P8U3/ P8U3/ P8U3/ P8U3/ P8U3/ P8U3/ P8U3/ ACCESSORIES 2 mm 25mm 2 for 00A Type/ No. of Length Cat. No. Pins [mm] 3P25U3/ P25U3/ P25U3/ P25U3/ P25U3/ P25U3/ P25U3/ P25U3/ P25U3/ P25U3/ P25U3/ P25U3/ P25U3/ P25U3/ P25U3/ P25U3/ P25U3/ P25U3/ Type/Cat. No: P50UT P50UB P95UB Description: Power Feed Lug Modular Direct Power Feed Power Feed Block Type/Cat. No: BRB5W 8/25CAP3P Description: Insulation Cap End Cap shown: 3P8U3/2 76 Altech Corp. 35 Royal Road Flemington, NJ P F

77 3 PHASE BUSBAR - /2 pole spacing 8mm 2 for 80A / 25mm 2 for 00A UL508 listed E mm 6 mm 62.3 mm 3x62.3 = 86.9 mm 2x7.8 = 35.6 mm 8mm² 25mm².5 mm 2 mm 2 mm 36.5 mm 36.5 mm 2 mm UL mm 2.6 mm 8mm 2 for 80A Type/ No. of Length Cat. No. Pins [mm] 3P8U3H/6 6 3P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ ACCESSORIES mm 25mm 2 for 00A Type/ No. of Length Cat. No. Pins [mm] 3P25U3H/6 6 3P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ Type/Cat. No: P50UT P50UB Description: Power Feed Lug Modular Direct Power Feed Type/Cat. No: BRB5W 8/25CAP3P Description: Insulation Cap End Cap shown: 3P8U3H/2 ANNEX Altech Corp. 35 Royal Road Flemington, NJ P F

78 UL 89 Power Feed Devices Easy connection of power supply wires to the busbar/mcb. Power Feed Devices ensure permanent connection. Power Feed Lug Power Feed Lug Modular Direct Power Feed ANNEX Type/Cat. No. P50UT-LP P50UT P50UB Electrical Ratings 5A/000V AC/DC 5A/000V AC/DC 5A/000V AC/DC Wire Range 0-/0 AWG Cu 0-/0 AWG Cu - AWG Cu Wire Temperature Rating 60 C 60 C 75 C Recommended/ Required Torque 5.6Nm (50lb. in.) 5.6Nm (50lb. in.) Material of Lug/ Terminal Brass Brass Brass Insulation Material Polyamide Polyamide Polyamide For use with UL077/508 8 and 25mm 2 UL077/508 8 and 25mm 2 UL077/508 8 and 25mm 2 phase busbars 2, 3 phase busbars, 2, 3 phase busbars Dimensions 37.6 mm 6 mm Ø Assembly Instructions UL508 listed E2052 The power feed lugs (Cat. # P50UT) fit together with the lugs of the busbar in the terminals of the connected device. 2 mm 6. mm 28.5 mm 3.9 mm 3 mm 3P8U3/XX + 3 x P50UT 59 mm 6.3 mm Ø 6.2 mm 8.5 mm 2 mm UL508 listed E mm 3 mm Cable Side Busbar Side 7.75 mm 0. mm mm UL508 listed E Nm/3 lb. in. (-6AWG) Nm/35. lb. in. (-AWG) 2.5Nm/22 lb. in mm 29.8 mm 2.3 mm 0 mm 3P8U3/XX + 3 x P50UB 7.75 mm 78 Altech Corp. 35 Royal Road Flemington, NJ P F

79 Power Feed Block Dimensions UL 89 UL508 listed E mm Type/Cat. No. P95UB Electrical Ratings 200A/ 600V AC/DC Wire Range -/0 AWG Cu Wire Temperature Rating 75 C Recommended/ Required Torque Material of Lug/ Terminal 9.5Nm (75lb. in.) Brass Insulation Material Polyamide For use with UL077/508 8 and 25mm 2 3 phase busbars (standard spacing only) Assembly Instructions Miscellaneous Accessories 8/25CAPP Type/Cat. No: For use with: Type/Cat. No: For use with: End Caps 8/25CAP3P 8/25CAPP 8/25mm 2 phase Busbar 8/25CAP3P 8/25mm 2 2, 3 phase Busbar 3.6 mm 3.6 mm 35.6 mm 88.3 mm 35.6 mm Phase Pin Phase Phase 2 Phase 3 Insulation Caps 62.5 mm NOTE: The Power Feed Block uses the space of 5 Pins of the standard spacing Busbar (see drawing below). Phase connects to Pin, Phase 2 to Pin 3 and Phase 3 to Pin 5. Pin 2 and are not in use. Pin 6 should be covered with an insulation cap if phase sequence stays the same. Therefore, the Power Feed Block covers 6 pins to connect to the three phases. Type/Cat. No: BRB5W (5 per strip) For use with: 8/25mm 2, 2, 3 phase Busbar 63 mm ANNEX Altech Corp. 35 Royal Road Flemington, NJ P F

80 UL 89 ANNEX TR Series UL077 Recognized Supplementary Protector/ Circuit Breaker for Equipment Applications: Protection of Control Transformers, UPS, Power strips, Solenoids etc., against damage due to overload conditions. Current Rating (A) A Standard Current Rating (A) 0., 0.25, 0.5, 0.9,.0,.2,.5,.8, 2.0, 2.2, 2.5, 2.7, 3.0, 3.3,.0, 5.0, 6.0, 6.5, 7.0, 8.0, 9.0, 0.0, 2.0, 5.0, 6.0 Rated Voltage 20V AC, 50/60Hz, 50V DC / 2V DC (VDE) Initial insulation resistance (500V DC) > 00 M ohms. (As per EN 6093) Dielectric strength Overload Switching Capacity.5 KV for One minute. 6 I n - AC up to 9.0A (As per EN 6093) I n - DC up to 2.0A (As per EN 6093) 60A AC/DC Max. - from 0.0A to 2.0A Maximum Breaking Capacity 8x I n AC/DC for <6.0A 60A AC/DC MAX. for > 6.0A Power Loss - 2 Watts Operating Temperature Maximum 60 C Ambient Operational Life at 2xI n 000 Cycles Rated Conditional Short Circuit 000 Amps PC,20V AC, 2V DC, Ref.: EN6093 Current Capacity I nc (PC) SC: KA, C, 20V AC 50V DC Ref.: EN6093 Ref.: CSA22.2 No.235-0, UL-077 Tripping Current Code TC TC 2Ref.: CSA22.2 No Overload Rating OL0 20V AC, 50V DC, Ref.: CSA22.2 No Application Type General Industrial Ref.: CSA22.2 No Method of Tripping Thermal TO Trip Free Type of Actuation Reset Type R Application Standards CSA 22.2 No , UL-077, EN 6093 Weight aprox. g Approvals ORDERING INSTRUCTIONS PRODUCT TYPE A 20V AC 50V DC CURRENT RATING 0. TO 6.0A MOUNTING NUT A 20V AC 2V DC E (min) Trip time 0 5 (S) Operating Characteristic up to 2 Amps Multiple of Rated Current Rated current Ambient Temperature * SPECIAL ORDER ONLY. Contact Altech for more details. TR-C Series stocked; contact Altech for availability. PCB Mounting and additional Shunt Terminal available, please contact Altech. < 6 A > 6 A 23 C Time Current Characteristics: The standard characteristic is valid for ambient temperatures of +23 C. If the device is to be used in an ambient temperature other than +23 C, allowances must be made when selecting the current rating according to the following guidelines: 0 Ambient temp. C Correction Factor Example: Normal Continuous Current.8A Ambient Temperature 0 C Correction Factor.2 Recommended Current Rating.8 x.2 = 2.06 Select the nearest 2.0A 80 Altech Corp. 35 Royal Road Flemington, NJ P F

81 TR- Dimensions & Mounting Options Central Mounting UL 89 Wing Clips Snap Fitting Body Mounting Slider Printing for Current Rating Accessories PCB Mounting Wing Clip Types Slider Color with Trip Band ANNEX Dimensions in mm (to convert to inches multiply by ) Altech Corp. 35 Royal Road Flemington, NJ P F

82 TR- Dimensions & Mounting Options Central Mounting UL 89 Wing Clips Snap Fitting Body Mounting Slider Printing for Current Rating Accessories PCB Mounting Wing Clip Types Slider Color with Trip Band ANNEX Dimensions in mm (to convert to inches multiply by ) 8

83 UL 89 ANNEX TR20 Series UL077 Recognized Supplementary Protector/ Circuit Breaker for Equipment Applications: Protection of Control Transformers, UPS, Power strips, Solenoids etc., against damage due to overload conditions. Application Type General Industrial Ref. CSA22.2 No Function SPST Standard Current Rating (A) 3,, 5, 6, 7, 8, 0, 2, 5, 6 & 20 AC-Inductive, DC-Resistive Rated Voltage 25/25V AC, 50/60 Hz, 50V DC Method of tripping Thermol TO, Cycling trip - free Type of Actuation Reset Type R Initial insulation resistance > 00 M ohms. (DC500V) Dielectric strength.500 KV for minute Impulse withstand voltage 2.5kV Ref.: EN 6093 Contact Gap Micro disconnection(μ) Ref.: EN6093 Housing Material Thermoplastic / Thermoset Slider Material Thermoset Contact Material Silver alloy Terminal Material Copper alloy Fixing By a nut or snap fitting Resettable overload capacity 0 times the rated current Overload capacity 2 times rated current for 50 switching cycles min. Ref.: Rated Short Circuit Capacity I cn Ref.: EN6093 Min 6 times the rated current (6 In ) for 250V AC (Inductive) Min times the rated current ( In ) for 50V DC (Resistive) Rated Conditional Short Circuit Current Capacity I nc (PC) Ref.: EN Amps 25/250V AC, 50V DC SC: ka, C, 25/250V AC, 50V AC Ref.: CSA22.2 No.235-0, UL-077 Tripping Current Code TC TC 2Ref.: CSA22.2 No Overload Rating OLO 25/250V AC, 50V DC, Ref.: CSA 22.2 No Weight aprox. 7g Application Standards, CSA 22.2 No , EN 6093 Approvals ORDERING INSTRUCTIONS PRODUCT TYPE TR20 C 63 S B A 7.0A 2 TERMINAL CONFIGURATION SLIDER COLOR White with trip indication 0 None White, Vertical 2 Black, Vertical 3 White, Horizontal Black, Horizontal CURRENT RATING 3A, A, 5A, 6A, 7A, 8A, 0A, 2A, 5A, 0A & 20A MOUNTING NUT INDICATOR PLATE * SPECIAL ORDER ONLY. Contact Altech for more details. PCB Mounting and additional Shunt Terminal available, please contact Altech. E Ambient temp. C Multiplication Factor 3A to A Multiplication Factor 5A to 20A Example: Normal Continuous Current Ambient Temperature Multiplication Factor Selected rated current at +0 C Ambient temperature up to 2 Amps Operating Characteristic Time Current Characteristics: The standard characteristic is valid for ambient temperatures of +25 C. If the device is to be used in an ambient temperature other than +25 C, allowances must be made when selecting the current rating according to the following guidelines: A 0 C. 5 x. = A (nearest) 82 Altech Corp. 35 Royal Road Flemington, NJ P F

84 TR-20 Dimensions & Mounting Options Central Mounting Wing Clips UL 89 Slider Printing for Current Rating Accessories Dimensions in mm (to convert to inches multiply by ) Terminal Options ANNEX Altech Corp. 35 Royal Road Flemington, NJ P F

85 UL 89 ANNEX TR30 Series UL077 Recognized Supplementary Protector/ Circuit Breaker for Equipment Applications: Protection of Control Transformers, UPS, Power strips, Solenoids etc., against damage due to overload conditions. Application Type Function Standard Current Rating (A) Rated Voltage Method of tripping Type of Actuation Initial insulation resistance Dielectric strength Impulse withstand voltage Contact Gap Housing Material Slider Material Contact Material Terminal Material Fixing Resettable overload capacity General Industrial Ref. CSA22.2 No SPST 5A-25A 5A, 6A, 7A, 0A, 2A, 5A, 20A, 25A, 30A & 35A 25/25V AC, 50/60 Hz, 50V DC Thermol TO, Cycling trip - free Reset Type R Rated Short Circuit Capacity I cn Min 6 times the rated current (6 In ) for 250V AC (Inductive) Ref.: EN6093 Min times the rated current ( In ) for 50V DC (Resistive) Rated Conditional Short Circuit ka, 5 to 5A, 250V AC, 2kA, 20 to 35A, 250V AC, Current Capacity I nc (PC) ka, 5 to 35A, 50V DC As per EN6093 ka, C, 50V Dc, -(5-35A); 500A, U3, 25V AC, -(20-35A); As per CSA 22.2 No & ka, Ua, 25V AC, -(5-35A); 2kA, C, 25V AC, -(5-35A); ka, C, 250V AC, -(5-5A); 2kA, C, 250V AC, -(20-35A) Tripping Current Code TC TC 3 Ref.: CSA22.2 No Overload Rating 5-35A - OL0 25/250V AC, 50V DC; As per CSA 22.2 No A - OL 25V AC; 5-35A - OL 250V AC Weight aprox. 25g Application Standards, CSA 22.2 No , EN 6093, UL 500 Approvals Ignition Protected > 00 M ohms. (DC500V).500 KV for minute 2.5kV Ref.: EN 6093 Micro disconnection(μ) Ref.: EN6093 Thermoset - UL9-V0 flammability class Thermoset - UL9-V0 flammability class Silver alloy Copper alloy By a nut or snap fitting 0 times the rated current ORDERING INSTRUCTIONS PRODUCT TYPE TERMINAL CONFIGURATION Compliant as per UL 500 (Standard for safety for Ignition protection test for Marine products) TR30 C 63 S W A 7.0A 2 SLIDER COLOR CURRENT RATING 5A, 6A, 7A, 0A, 2A, 5A, 20A, 25A, 30A & 35A MOUNTING NUT Note: Color of marking is standard. On red / black slider -white marking white slider -black marking. INDICATOR PLATE * SPECIAL ORDER ONLY. Contact Altech for more details. PCB Mounting and additional Shunt Terminal available, please contact Altech. E up to 2 Amps Ambient temp. C Multiplication Factor 5A Multiplication Factor 56A to 30A Multiplication Factor 35A Example: Operating Characteristic Time Current Characteristics: The standard characteristic is valid for ambient temperatures of +25 C. If the device is to be used in an ambient temperature other than +25 C, allowances must be made when selecting the current rating according to the following guidelines: Normal Continuous Current Ambient Temperature Multiplication Factor Selected rated current at +0 C ambient temperature 5.0A 0 C.5 5 x.5 = A (nearest) 8 Altech Corp. 35 Royal Road Flemington, NJ P F

86 TR-30 Dimensions & Mounting Options Central Mounting UL 89 Wing Clips Slider Printing for Current Rating Accessories Dimensions in mm (to convert to inches multiply by ) Terminal Options ANNEX Altech Corp. 35 Royal Road Flemington, NJ P F

87 UL 89 ANNEX RP - Series RCCB RCCB Series compact Earth Leakage Circuit Break ers de tect and in ter rupt earth (ground) faults. They are VDE approved for the Eu - ro pe an system of pro tect ing peo - ple, animals, equipment and prop - er ty from danger ous line-to-ground and shock haz ard cur rents. US applications include groundfault pro tec tion of equip ment (GFPE) using the 0mA and 30mA fault current rat ings, es pe cial ly when high distributed ca pac i tance or other leakag es cause ex ces sive nui sance trips at lower fault cur - rents. Applications for the 300mA and 500mA ratings are equip ment protection and fire preven tion, lim - it ing the energy of a fault to less than the minimum ignition en er gy for many materials. Type Designation RP (a) (b) (c) (a) = 2-2 pole; - pole (b) = -6A; 2-25A; 3-0A; -63A; 5-80A; 6-00A; 7-25A (c) = 0-0mA = 03-30mA = mA = mA Voltage Rating (maximum) Short Circuit Withstand Rating Fault Trip Current Calibration Typical Life Standard Pack and Weight Terminal Size Acceptability Terminal Torque a For 2-Phase applications, terminal 5 and 6 (next to Neutral terminals) must be connected to one phase for the test circuit to be operable. b For voltage systems without a neutral conductor. Please use jumper from or 3 to top N terminal. This will assure proper functioning of the test circuit. Note: If the power system has a marked conductor, it must connect through the FI and not be grounded at any point downstream. RP2 Maximum Rated Fault Line Trip Current Current Cat. No. 6A 0mA RP20 25A 30mA RP A 300mA RP A 0A 30mA RP2303 0A 300mA RP2330 0A 63A 30mA RP203 63A 300mA RP230 63A 500mA RP250 80A 80A 80A 00A 00A 00A 25A 25A 25A Stock items are shown in BOLD. 230V AC, 50Hz /N Fault Trip Current 30mA 300mA 500mA 30mA 300mA 500mA 30mA 300mA 500mA 30mA 300mA 500mA 30mA 300mA 500mA 30mA 300mA 500mA 00Y/230V AC, 50Hz RP /N RH - Auxiliary Contact and Signal Switch (switchable) (C.O./N.C.) Cat. No. RP203 RP230 RP250 RP303 RP330 RP350 RP03 RP30 RP50 RP503 RP530 RP550 RP603 RP630 RP650 RP703 RP730 RP750 No back-up fuse: Rated current (RC) 6/25/0A: 500A; RC 63/80A: 800A; RC 00A: 000A; RC 25A- 250A. With back-up fuse: 0kA; Size of fuse: (2 pole version): RC 25/0/63: 00A; ( pole version): RC 25/0/63A: 00A; RC 80/00/25A: 25A FI trips are calibrated at less than fault trip current for ensured safety (Typical trip range between % fault trip current, e.g., typical trip at 20-25mA for fault RC of 30mA) Fully functional after 5,000 operations to DIN/VDE 066T0, IEC and 2000 additional fault current trips. /230g (0.6 lb.) /20-60g (0.9 lb.-.0 lb.).5-50mm 2 (6- AWG).5-50mm 2 (6- AWG) 3Nm (26.5 lb.in.) 3Nm (26.5 lb.in.) Circuit Diagram Contact Wire Rating Size Torque Cat. No. Circuit Diagram 6A / 230V AC -.5mm 2 (6 AWG) max. 0.8Nm (7lb.in.) RH A / 0V DC Std. Pk.: Unit 5 grams (0.2 lb.) Width: 9mm (.35in.) 2 22 a, b 2 86 Altech Corp. 35 Royal Road Flemington, NJ P F

88 Dimensions in mm ANNEX UL 89 Temperature Range Fluctuating Climate Conditions Electrical Shock Protection Impact/Shock Protection Vibration/Seismic Resistance Protection Class Non-Sinusoidal Fault Insulation Category RP2 RP RP2 and RP Environmental Information marked with Snowflake approval for -25 C to 0 C (-3 F to 0 F) ambient temperature. (Temperature effect on RC: for every 0 C temperature rise above 0 C decrease RC by 7%.) According to IEC : heat (25 C~55 C), relative humidity (93%~95%) Uninsulated electrically live parts within 30mm of the operating handle are finger safe (terminal screw heads) and uninsulated live parts within 00mm of the operating handle are back-ofhand safe (terminals). 20g with impact force half-cycle sinusoidal and 20ms duration, 8 impacts total with 6 on each principal axis (3 impacts each face). FI is DIN Rail mounted during the test, and electrically loaded with 25% of Fault RC. Successful testing required no trip during the test, no damage and no loosened parts. 5g, at frequency of 80Hz, applied for 30 minutes along each of the three principal axes, plus 5 minutes of application at every established critical resonant frequency. FI is DIN Rail mounted during the test, and loaded with 25% Fault RC. To pass, the FI did not trip at 25% Fault RC, but did trip between each of the principal axis tests when the fault current was raised to 25% Fault RC, and there was no damage and no loosened parts. Suitable for machinery and mobile vehicle applications. IP20; higher protection Class is dependent on housing. The FI is tested and approval stamped for tripping sensitivity to non-sinusoidal fault currents, which become zero or almost zero within one cycle of the line frequency. Waveforms and allowed trip-current ranges are as follows:. AC Sinusoidal Fault times Fault RC 2a. Pulsating DC Fault; Positive and Negative Half-Waves times Fault RC 2b. Phased Half-Wave, times Fault RC Phased Half-Wave, times Fault RC 3. Pulsating DC on 6mA DC (continuous) Base - Max.. times Fault RC + 6mA At VDE rated voltage, suitable for Class C environments with relatively high dust and moisture levels and little HVAC control, e.g., industrial, commercial, agricultural; on machine tools, hoists, warehouse equipment, etc.; in boiler rooms, unheated storage, covered shipping/receiving, open workshops, etc. Altech Corp. 35 Royal Road Flemington, NJ P F

89 UL 89 ANNEX Index Part No. Page Part No. Page Part No. Page Part No. Page Part No. Page Part No. Page /25CAPP /25CAP3P...79 B05UR...56 B.6UM...38 B0UM...38 B0UR...56 B2UR...56 B3UM...38 B3UR...56 B5UM...38 B5UR...56 B6UM...38 B6UR...56 BUM...38 BUR...56 B2.5UM...38 B20UM...38 B20UR...56 B25UR...56 B25UZ...38 B2UM...38 B2UR...56 B3.5UM...38 B30UM...38 B30UR...56 B32UM...38 B32UR...56 B3UM...38 B3UR...56 B0UM...38 B0UR...56 BUM...38 BUR...56 B50UM...38 B50UR...56 B5UM...38 B5UR...56 B60UM...38 B60UR...56 B63UM...38 B63UR...56 B6UM...38 B6UR...56 B8UR...56 BU05R...6 BU0R...6 BU2R...6 BU3R...6 BU5R...6 BU6R...6 BUR...6 BU20R...6 BU25R...6 BU2R...6 BU30R...6 BU32R...6 BU3R...6 BU0R...6 BUR...6 BU50R...6 BU5R...6 BU60R...6 BU63R...6 BU6R...6 BU8R...6 C03DL... C03UL...2 C03UM...39 C05DL... C05UL...2 C05UM...39 C05UR...57 C075UM...39 C.6DL... C.6UL...2 C.6UM...39 C0DL... C0UL...2 C0UM...39 C0UR...57 C2DL... C2UL...2 C2UR...57 C3DL... C3UL...2 C3UM...39 C3UR...57 C5DL... C5UL...2 C5UM...39 C5UR...57 C6DL... C6UL...2 C6UM...39 C6UR...57 CDL... CUL...2 CUM...39 CUR...57 C2.5UM...39 C20DL... C20UL...2 C20UM...39 C20UR...57 C25DL... C25UL...2 C25UM...39 C25UR...57 C2DL... C2UL...2 C2UM...39 C2UR...57 C3.5UM...39 C30DL... C30UL...2 C30UM...39 C30UR...57 C32DL... C32UL...2 C32UM...39 C32UR...57 C3DL... C3UL...2 C3UM...39 C3UR...57 C0DL... C0UL...2 C0UM...39 C0UR...57 CDL... CUL...2 CUM...39 CUR...57 C50DL... C50UL...2 C50UM...39 C50UR...57 C5DL... C5UL...2 C5UM...39 C5UR...57 C60DL... C60UL...2 C60UM...39 C60UR...57 C63DL... C63UL...2 C63UM...39 C63UR...57 C6DL... C6UL...2 C6UM...39 C6UR...57 C8DL... C8UL...2 C8UM...39 C8UR...57 CU02L...22 CU05L...22 CU05R...65 CU.6L...22 CU0L...22 CU0R...65 CU2L...22 CU2R...65 CU3L...22 CU3R...65 CU5L...22 CU5R...65 CU6L...22 CU6R...65 CUL...22 CUR...65 CU20L...22 CU20R...65 CU25L...22 CU25R...65 CU2L...22 CU2R...65 CU30L...22 CU30R...65 CU32L...22 CU32R...65 CU3L...22 CU3R...65 CU0L...22 CU0R...65 CUL...22 CUR...65 CU50L...22 CU50R...65 CU5L...22 CU5R...65 CU60L...22 CU60R...65 CU63L...22 CU63R...65 CU6L...22 CU6R...65 CU8L...22 CU8R...65 D03DL...5 D03UL...3 D03UM...0 D05DL...5 D05UL...3 D05UM...0 D05UR...58 D075UM...0 D.6DL...5 D.6UL...3 D.6UM...0 D0DL...5 D0UL...3 D0UM...0 D0UR...58 D2DL...5 D2UL...3 D2UR...58 D3DL...5 D3UL...3 D3UM...0 D3UR...58 D5DL...5 D5UL...3 D5UM...0 D5UR...58 D6DL...5 D6UL...3 D6UM...0 D6UR...58 DDL...5 DUL...3 DUM...0 DUR...58 D2.5UM...0 D20DL...5 D20UL...3 D20UM...0 D20UR...58 D25DL...5 D25UL...3 D25UM...0 D25UR...58 D2DL...5 D2UL...3 D2UM...0 D2UR...58 D3.5UM...0 D30DL...5 D30UL...3 D30UM...0 D30UR...58 D32DL...5 D32UL...3 D32UM...0 D32UR...58 D3DL...5 D3UL...3 D3UM...0 D3UR...58 D0DL...5 D0UL...3 D0UM...0 D0UR...58 DDL...5 DUL...3 DUM...0 DUR...58 D50DL...5 D50UL...3 D50UM...0 D50UR...58 D5DL...5 D5UL...3 D5UM...0 D5UR...58 D60DL...5 D60UL...3 D60UM...0 D60UR...58 D63DL...5 D63UL...3 D63UM...0 D63UR...58 D6DL...5 D6UL...3 D6UM...0 D6UR...58 D8DL...5 D8UL...3 D8UM Altech Corp. 35 Royal Road Flemington, NJ P F

90 Index Part No. Page Part No. Page Part No. Page Part No. Page Part No. Page Part No. Page D8UR...58 DU02L...23 DU05L...23 DU05R...66 DU.6L...23 DU0L...23 DU0R...66 DU2L...23 DU2R...66 DU3L...23 DU3R...66 DU5L...23 DU5R...66 DU6L...23 DU6R...66 DUL...23 DUR...66 DU20L...23 DU20R...66 DU25L...23 DU25R...66 DU2L...23 DU2R...66 DU30L...23 DU30R...66 DU32L...23 DU32R...66 DU3L...23 DU3R...66 DU0L...23 DU0R...66 DUL...23 DUR...66 DU50L...23 DU50R...66 DU5L...23 DU5R...66 DU60L...23 DU60R...66 DU63L...23 DU63R...66 DU6L...23 DU6R...66 DU8L...23 DU8R...66 E03UM... E05UM... E075UM... E.6UM... E0UM... E2UM... E3UM... E5UM... E6UM... EUM... E2.5UM... E20UM... E25UM... E2UM... E3.5UM... E30UM... E32UM... E3UM... E0UM... EUM... E50UM... E5UM... E60UM... E63UM... E6UM... E8UM... G03UM...2 G05UM...2 G08UM...2 G.6UM...2 G0UM...2 G2UM...2 G3UM...2 G5UM...2 G6UM...2 GUM...2 G2.5UM...2 G20UM...2 G25UM...2 G2UM...2 G3.5UM...2 G30UM...2 G32UM...2 G3UM...2 G0UM...2 GUM...2 G50UM...2 G5UM...2 G60UM...2 G63UM...2 G6UM...2 G8UM...2 P6UL3/ P6UL3/ P6UL3/ P8U/ P8U/...72 P8U/ P8U/ P8U/...72 P8U/ P8U/ P8U/ P8U/ P8U/ P8U/ P8U/ P8U/ P8U/ P8U/ P8U/ P8U/ P8U/ P8U/ P8U/ P8U/ P8U/ P8U/ P8U/ P8U/ P8U/ P8U/ P8U/ P8U/ P8U/ P8U/ P8U/ P8U/...72 P8U/ P8U/...72 P8U/ P8U/ P8U/...72 P8U/ P8U/ P8U/ P8U/ P8U/ P8U/ P8U/ P8U/ P8U/ P8U/ P8U/ P8U/ P8U/ P8U/ P8U/ P8U/ P8U/ P8U/ P8UH/ P8UH/...73 P8UH/ P8UH/ P8UH/...73 P8UH/ P8UH/ P8UH/ P8UH/ P8UH/ P8UH/ P8UH/ P8UH/ P8UH/ P8UH/ P8UH/ P8UH/ P8UH/ P8UH/ P8UH/ P8UH/ P8UH/ P8UH/ P8UH/ P8UH/ P8UH/ P8UH/ P8UH/ P8UH/ P8UH/...73 P8UH/ P8UH/ P8UH/ P8UH/ P8UH/ Z03UM...3 Z05UM...3 Z075UM...3 Z.6UM...3 Z0UM...3 Z2UM...3 Z3UM...3 Z5UM...3 Z6UM...3 ZUM...3 Z2.5UM...3 Z20UM...3 Z25UM...3 Z2UM...3 Z3.5UM...3 Z30UM...3 Z32UM...3 Z3UM...3 Z0UM...3 ZUM...3 Z50UM...3 Z5UM...3 Z6UM...3 Z8UM...3 2B05UR B.6UM B0UM B0UR B2UR B3UM B3UR B5UM B5UR B6UM B6UR BUM BUR B2.5UM B20UM B20UR B25UM B25UR B2UM B2UR B3.5UM B30UM B30UR B32UM B32UR B3UM B3UR B0UM B0UR BUM BUR B50UM B50UR B5UM B5UR B60UM B60UR B63UM B63UR B6UM B6UR B8UR BU05R...6 2BU0R...6 2BU2R...6 2BU3R...6 2BU5R...6 2BU6R...6 2BUR...6 2BU20R...6 2BU25R...6 2BU2R...6 2BU30R...6 2BU32R...6 2BU3R...6 2BU0R...6 2BUR...6 2BU50R...6 2BU5R...6 2BU60R...6 2BU63R...6 2BU6R...6 2BU8R...6 2C03DL... 2C03UL...2 2C03UM C05DL... 2C05UL...2 2C05UM C05UR C075UM C.6DL... 2C.6UL...2 2C.6UM C0DL... 2C0UL...2 2C0UM C0UR C2DL... UL 89 ANNEX Altech Corp. 35 Royal Road Flemington, NJ P F

91 UL 89 ANNEX Index Part No. Page Part No. Page Part No. Page Part No. Page Part No. Page Part No. Page 2C2UL...2 2C2UR C3DL... 2C3UL...2 2C3UM C3UR C5DL... 2C5UL...2 2C5UM C5UR C6DL... 2C6UL...2 2C6UM C6UR CDL... 2CUL...2 2CUM CUR C2.5UM C20DL... 2C20UL...2 2C20UM C20UR C25DL... 2C25UL...2 2C25UM C25UR C2DL... 2C2UL...2 2C2UM C2UR C3.5UM C30DL... 2C30UL...2 2C30UM C30UR C32DL... 2C32UL...2 2C32UM C32UR C3DL... 2C3UL...2 2C3UM C3UR C0DL... 2C0UL...2 2C0UM C0UR CDL... 2CUL...2 2CUM CUR C50DL... 2C50UL...2 2C50UM C50UR C5DL... 2C5UL...2 2C5UM C5UR C60DL... 2C60UL...2 2C60UM C60UR C63DL... 2C63UL...2 2C63UM C63UR C6DL... 2C6UL...2 2C6UM C6UR C8DL... 2C8UL...2 2C8UM C8UR CU02L CU05L CU05R CU.6L CU0L CU0R CU2L CU2R CU3L CU3R CU5L CU5R CU6L CU6R CUL CUR CU20L CU20R CU25L CU25R CU2L CU2R CU30L CU30R CU32L CU32R CU3L CU3R CU0L CU0R CUL CUR CU50L CU50R CU5L CU5R CU60L CU60R CU63L CU63R CU6L CU6R CU8L CU8R D03DL...5 2D03UL...3 2D03UM...0 2D05DL...5 2D05UL...3 2D05UM...0 2D05UR D075UM...0 2D.6DL...5 2D.6UL...3 2D.6UM...0 2D0DL...5 2D0UL...3 2D0UM...0 2D0UR D2DL...5 2D2UL...3 2D2UR D3DL...5 2D3UL...3 2D3UM...0 2D3UR D5DL...5 2D5UL...3 2D5UM...0 2D5UR D6DL...5 2D6UL...3 2D6UM...0 2D6UR DDL...5 2DUL...3 2DUM...0 2DUR D2.5UM...0 2D20DL...5 2D20UL...3 2D20UM...0 2D20UR D25DL...5 2D25UL...3 2D25UM...0 2D25UR D2DL...5 2D2UL...3 2D2UM...0 2D2UR D3.5UM...0 2D30DL...5 2D30UL...3 2D30UM...0 2D30UR D32DL...5 2D32UL...3 2D32UM...0 2D32UR D3DL...5 2D3UL...3 2D3UM...0 2D3UR D0DL...5 2D0UL...3 2D0UM...0 2D0UR DDL...5 2DUL...3 2DUM...0 2DUR D50DL...5 2D50UL...3 2D50UM...0 2D50UR D5DL...5 2D5UL...3 2D5UM...0 2D5UR D60DL...5 2D60UL...3 2D60UM...0 2D60UR D63DL...5 2D63UL...3 2D63UM...0 2D63UR D6DL...5 2D6UL...3 2D6UM...0 2D6UR D8DL...5 2D8UL...3 2D8UM...0 2D8UR DU02L DU05L DU05R DU.6L DU0L DU0R DU2L DU2R DU3L DU3R DU5L DU5R DU6L DU6R DUL DUR DU20L DU20R DU25L DU25R DU2L DU2R DU30L DU30R DU32L DU32R DU3L DU3R DU0L DU0R DUL DUR DU50L DU50R DU5L DU5R DU60L DU60R DU63L DU63R DU6L DU6R DU8L DU8R E03UM... 2E05UM... 2E075UM... 2E.6UM... 2E0UM... 2E2UM... 2E3UM... 2E5UM... 2E6UM... 2EUM... 2E2.5UM... 2E20UM... 2E25UM... 2E2UM... 2E3.5UM... 2E30UM... 2E32UM... 2E3UM... 2E0UM... 2EUM... 2E50UM... 2E5UM... 2E60UM... 2E63UM... 2E6UM... 2E8UM... 2G03UM...2 2G05UM...2 2G08UM...2 2G.6UM...2 2G0UM...2 2G2UM...2 2G3UM...2 2G5UM...2 2G6UM...2 2GUM...2 2G2.5UM...2 2G20UM Altech Corp. 35 Royal Road Flemington, NJ P F

92 Index Part No. Page Part No. Page Part No. Page Part No. Page Part No. Page Part No. Page 2G25UM...2 2G2UM...2 2G3.5UM...2 2G30UM...2 2G32UM...2 2G3UM...2 2G0UM...2 2GUM...2 2G50UM...2 2G5UM...2 2G60UM...2 2G63UM...2 2G6UM...2 2G8UM...2 2P6UL3/ P6UL3/ P6UL3/ P8U3/ P8U3/ P8U3/...7 2P8U3/ P8U3/ P8U3/ P8U3/ P8U3/ P8U3/ P8U3/ P8U3/ P8U3/ P8U3/ P8U3/ P8U3/ P8U3/...7 2P8U3/ P8U3/ P8U3/...7 2P8U3/ P8U3/ P8U3/ P8U3/ P8U3/ P8U3/ P8U3/ P8U3/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ P25U3/ P25U3/ P25U3/...7 2P25U3/ P25U3/ P25U3/ P25U3/ P25U3/ P25U3/ P25U3/ P25U3/ P25U3/ P25U3/ P25U3/ P25U3/ P25U3/...7 2P25U3/ P25U3/ P25U3/...7 2P25U3/ P25U3/ P25U3/ P25U3/ P25U3/ P25U3/ P25U3/ P25U3/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ Z03UM...3 2Z05UM...3 2Z075UM...3 2Z.6UM...3 2Z0UM...3 2Z2UM...3 2Z3UM...3 2Z5UM...3 2Z6UM...3 2ZUM...3 2Z2.5UM...3 2Z20UM...3 2Z25UM...3 2Z2UM...3 2Z3.5UM...3 2Z30UM...3 2Z32UM...3 2Z3UM...3 2Z0UM...3 2ZUM...3 2Z50UM...3 2Z5UM...3 2Z6UM...3 2Z8UM...3 3B05UR B.6UM B0UM B0UR B2UR B3UM B3UR B5UM B5UR B6UM B6UR BUM BUR B2.5UM B20UM B20UR B25UM B25UR B2UM B2UR B3.5UM B30UM B30UR B32UM B32UR B3UM B3UR B0UM B0UR BUM BUR B50UM B50UR B5UM B5UR B60UM B60UR B63UM B63UR B6UM B6UR B8UR BU05R...6 3BU0R...6 3BU2R...6 3BU3R...6 3BU5R...6 3BU6R...6 3BUR...6 3BU20R...6 3BU25R...6 3BU2R...6 3BU30R...6 3BU32R...6 3BU3R...6 3BU0R...6 3BUR...6 3BU50R...6 3BU5R...6 3BU60R...6 3BU63R...6 3BU6R...6 3BU8R...6 3C03UL...2 3C03UM C05UL...2 3C05UM C05UR C075UM C.6UL...2 3C.6UM C0UL...2 3C0UM C0UR C2UL...2 3C2UR C3UL...2 3C3UM C3UR C5UL...2 3C5UM C5UR C6UL...2 3C6UM C6UR CUL...2 3CUM CUR C2.5UM C20UL...2 3C20UM C20UR C25UL...2 3C25UM C25UR C2UL...2 3C2UM C2UR C3.5UM C30UL...2 3C30UM C30UR C32UL...2 3C32UM C32UR C3UL...2 3C3UM C3UR C0UL...2 3C0UM C0UR CUL...2 3CUM CUR C50UL...2 3C50UM C50UR C5UL...2 3C5UM C5UR C60UL...2 3C60UM C60UR C63UL...2 3C63UM C63UR C6UL...2 3C6UM C6UR C8UL...2 3C8UM C8UR CU02L CU05L CU05R CU.6L CU0L CU0R CU2L CU2R CU3L CU3R CU5L CU5R CU6L...22 UL 89 ANNEX Altech Corp. 35 Royal Road Flemington, NJ P F

93 UL 89 ANNEX Index Part No. Page Part No. Page Part No. Page Part No. Page Part No. Page Part No. Page 3CU6R CUL CUR CU20L CU20R CU25L CU25R CU2L CU2R CU30L CU30R CU32L CU32R CU3L CU3R CU0L CU0R CUL CUR CU50L CU50R CU5L CU5R CU60L CU60R CU63L CU63R CU6L CU6R CU8L CU8R D03UL...3 3D03UM...0 3D05UL...3 3D05UM...0 3D05UR D075UM...0 3D.6UL...3 3D.6UM...0 3D0UL...3 3D0UM...0 3D0UR D2UL...3 3D2UR D3UL...3 3D3UM...0 3D3UR D5UL...3 3D5UM...0 3D5UR D6UL...3 3D6UM...0 3D6UR DUL...3 3DUM...0 3DUR D2.5UM...0 3D20UL...3 3D20UM...0 3D20UR D25UL...3 3D25UM...0 3D25UR D2UL...3 3D2UM...0 3D2UR D3.5UM...0 3D30UL...3 3D30UM...0 3D30UR D32UL...3 3D32UM...0 3D32UR D3UL...3 3D3UM...0 3D3UR D0UL...3 3D0UM...0 3D0UR DUL...3 3DUM...0 3DUR D50UL...3 3D50UM...0 3D50UR D5UL...3 3D5UM...0 3D5UR D60UL...3 3D60UM...0 3D60UR D63UL...3 3D63UM...0 3D63UR D6UL...3 3D6UM...0 3D6UR D8UL...3 3D8UM...0 3D8UR DU02L DU05L DU05R DU.6L DU0L DU0R DU2L DU2R DU3L DU3R DU5L DU5R DU6L DU6R DUL DUR DU20L DU20R DU25L DU25R DU2L DU2R DU30L DU30R DU32L DU32R DU3L DU3R DU0L DU0R DUL DUR DU50L DU50R DU5L DU5R DU60L DU60R DU63L DU63R DU6L DU6R DU8L DU8R E03UM... 3E05UM... 3E075UM... 3E.6UM... 3E0UM... 3E2UM... 3E3UM... 3E5UM... 3E6UM... 3EUM... 3E2.5UM... 3E20UM... 3E25UM... 3E2UM... 3E3.5UM... 3E30UM... 3E32UM... 3E3UM... 3E0UM... 3EUM... 3E50UM... 3E5UM... 3E60UM... 3E63UM... 3E6UM... 3E8UM... 3G03UM...2 3G05UM...2 3G08UM...2 3G.6UM...2 3G0UM...2 3G2UM...2 3G3UM...2 3G5UM...2 3G6UM...2 3GUM...2 3G2.5UM...2 3G20UM...2 3G25UM...2 3G2UM...2 3G3.5UM...2 3G30UM...2 3G32UM...2 3G3UM...2 3G0UM...2 3GUM...2 3G50UM...2 3G5UM...2 3G60UM...2 3G63UM...2 3G6UM...2 3G8UM...2 3P6UL3/ P6UL3/ P6UL3/ P8U3/ P8U3/ P8U3/ P8U3/ P8U3/ P8U3/ P8U3/ P8U3/ P8U3/ P8U3/ P8U3/ P8U3/ P8U3/ P8U3/ P8U3/ P8U3/ P8U3/ P8U3/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ P8U3H/ P25U3/ P25U3/ P25U3/ P25U3/ P25U3/ P25U3/ P25U3/ P25U3/ P25U3/ P25U3/ P25U3/ P25U3/ P25U3/ P25U3/ P25U3/ P25U3/ P25U3/ P25U3/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ P25U3H/ Z03UM...3 3Z05UM...3 3Z075UM...3 3Z.6UM...3 3Z0UM...3 3Z2UM...3 3Z3UM...3 3Z5UM...3 3Z6UM...3 3ZUM...3 3Z2.5UM...3 3Z20UM...3 3Z25UM...3 3Z2UM...3 3Z3.5UM...3 3Z30UM...3 3Z32UM...3 3Z3UM...3 3Z0UM...3 3ZUM...3 3Z50UM...3 3Z5UM...3 3Z6UM Altech Corp. 35 Royal Road Flemington, NJ P F

94 Index Part No. Page Part No. Page Part No. Page Part No. Page Part No. Page Part No. Page 3Z8UM...3 ALTN ALTN2L...26 BRB5W...79 BS.UL...6 BS.UL...59 DCCU02L...2 DCCU05L...2 DCCU.6L...2 DCCU0L...2 DCCU2L...2 DCCU3L...2 DCCU5L...2 DCCU6L...2 DCCUL...2 DCCU20L...2 DCCU25L...2 DCCU2L...2 DCCU30L...2 DCCU32L...2 DCCU3L...2 DCCU0L...2 DCCUL...2 DCCU50L...2 DCCU5L...2 DCCU60L...2 DCCU63L...2 DCCU6L...2 DCCU8L...2 DCDU02L...2 DCDU05L...2 DCDU.6L...2 DCDU0L...2 DCDU2L...2 DCDU3L...2 DCDU5L...2 DCDU6L...2 DCDUL...2 DCDU20L...2 DCDU25L...2 DCDU2L...2 DCDU30L...2 DCDU32L...2 DCDU3L...2 DCDU0L...2 DCDUL...2 DCDU50L...2 DCDU5L...2 DCDU60L...2 DCDU63L...2 DCDU6L...2 DCDU8L...2 DC2CU02L...2 DC2CU05L...2 DC2CU.6L...2 DC2CU0L...2 DC2CU2L...2 DC2CU3L...2 DC2CU5L...2 DC2CU6L...2 DC2CUL...2 DC2CU20L...2 DC2CU25L...2 DC2CU2L...2 DC2CU30L...2 DC2CU32L...2 DC2CU3L...2 DC2CU0L...2 DC2CUL...2 DC2CU50L...2 DC2CU5L...2 DC2CU60L...2 DC2CU63L...2 DC2CU6L...2 DC2CU8L...2 DC2DU02L...2 DC2DU05L...2 DC2DU.6L...2 DC2DU0L...2 DC2DU2L...2 DC2DU3L...2 DC2DU5L...2 DC2DU6L...2 DC2DUL...2 DC2DU20L...2 DC2DU25L...2 DC2DU2L...2 DC2DU30L...2 DC2DU32L...2 DC2DU3L...2 DC2DU0L...2 DC2DUL...2 DC2DU50L...2 DC2DU5L...2 DC2DU60L...2 DC2DU63L...2 DC2DU6L...2 DC2DU8L...2 E E EASS...6 EASS...59 EASS EASS2L...27 FA0ACL...26 FA0ACR...68 FA0DCL...26 FA0DCR...68 FA0UL...6 FA0UM...50 FA0UM...59 FA20ACL...26 FA20ACR...68 FA2ACL...26 FA2ACR...68 FA2DCL...26 FA2DCR...68 FA2UL...6 FA2UM...50 FA2UM...59 FA230ACL...26 FA230ACR...68 FA2ACL...26 FA2ACR...68 FA2DCL...26 FA2DCR...68 FA2UL...6 FA2UM...50 FA2UM...59 FA277ACL...26 FA277ACR...68 FA00ACL...26 FA00ACR...68 FA8ACL...26 FA8ACR...68 FA8DCL...26 FA8DCR...68 FA8UL...6 FA8UM...50 FA8UM...59 FA60ACL...26 FA60ACR...68 FMAPL...27 FMA2PL...27 FMA3PL...27 G G G G G G G G GE H0UL...6 H0UM...50 H0UM...59 HUL...6 HUM...50 HUM...59 H2UL...6 H2UM...50 H2UM...59 HCOL...27 HCOR...69 H2UL...6 H2UM...50 H2UM...59 H2COL...27 H2COR...69 HLSL*...6 HLSM...59 HLSM*...50 HMS HMS HMS HMS...53 HMS HSTCOL...27 HSTCOR...69 MA06UM...8 MA025UM...8 MA00UM...8 MA063UM...8 MA.0UM...8 MA.6UM...8 MA0UM...8 MA6UM...8 MA2.5UM...8 MA20UM...8 MA25UM...8 MA32UM...8 MA.0UM...8 MA0UM...8 MA6.3UM...8 MS.F MS.G MS.PS MS.PV...53 MS.SLG MS.SLG MS.SLJ MS.SLJ MS.SLR MS.SLR MS.SLW MS.SLW MS MS MS MS MS...52 MS MS MS MS MS MS MS...52 MS N32UL...6 N63UL...6 N63UM...59 P35ULT...33 P50UB...78 P50ULB...33 P50UT...78 P50UT-LP...78 P95UB...79 RP RP RP RP RP RP RP RP RP RP RP RP RP RP RP RP RP RP RP RP RP RP RP RP RP RP TR-xx...80 TR20-xx...82 TR30-xx...8 UA20UL...6 UA20UM...50 UA20UM...59 UV0ACL...26 UV0ACR...68 UV0DCL...26 UV0DCR...68 UV20ACL...26 UV20ACR...68 UV2ACL...26 UV2ACR...68 UV2DCL...26 UV2DCR...68 UV230ACL...26 UV230ACR...68 UV2ACL...26 UV2ACR...68 UV2DCL...26 UV2DCR...68 UV277ACL...26 UV277ACR...68 UV00ACL...26 UV00ACR...68 UV8ACL...26 UV8ACR...68 UV8DCL...26 UV8DCR...68 UV60ACL...26 UV60ACR...68 UL 89 ANNEX Altech Corp. 35 Royal Road Flemington, NJ P F

95 UL 89 ANNEX Terms & Conditions TITLE - Title to the products of ALTECH shall remain with ALTECH until payment is made in full by Customer. Such reservation of title is for the purpose of securing the purchase price and shall not relieve Customer of the duty to inspect the products upon receipt, to notify ALTECH of any deficiencies or defects, and to exercise due care in the use, installation, operation, and maintenance of the products when on the premise of the Customer or under the control of the Customer. Notwithstanding any reservation of title by ALTECH, risk of loss shall pass to customer at any time of shipment. SHIPMENT AND DELIVERY - All orders for destination in the mainland United States (less Hawaii, Alaska and non-continental United States possessions) will be shipped F.O.B. Flemington, N.J. All destination, shipping and other charges shall be paid by the Customer in accordance with ALTECH s then current shipping and billing practices. Delivery dates given in the acceptance of any order are approximate. ALTECH shall not be liable for delays in delivery or in performance due to causes beyond its reasonable control including acts of God, acts of Customer, acts of civil or military authority, fires, strikes or other labor disturbances, war, riot or delays in transportation. In the event of such delay, the date of delivery or performance shall be extended for a period equal to the time lost by reason of the delay. PRICE - PRICES in any ALTECH publication are subject to change without prior notification. Catalog prices are based on prices published in the current price list. All written quotations are valid for thirty (30) days from the date of quotation. Customer shall pay all sales, use, excise or similar taxes whenever ALTECH must itself pay and/or collect such tax from Customer arising out of the sale. PAYMENT - Customer agrees to make payment within thirty (30) days of date of the invoice from ALTECH. Customer agrees to pay a late payment charge of one and one-half percent (.5% per month, or the maximum late payment charge permitted by applicable law, whichever is less, on any unpaid amount for each calendar month (or fraction thereof) that such payment is in default. Orders amounting to less than $00.00 will be billed at $00.00 plus freight. Full carton purchases are required. In the event of referral to an attorney for collection, reasonable attorney s fees for collection of the overdue amount shall be paid by Customer. In the event payment is not received within 30 days from the date of invoice, any discount shall be cancelled and the full list price will be due. LIMITED WARRANTY - ALTECH warrants to Customer that the equipment purchases shall be free from defects in material and workmanship under normal use and service for a period of one year from shipment. Written notice as an explanation of the circumstances of any claim that the equipment has proved defective in material or workmanship shall be given promptly by the Customer to ALTECH. ALTECH will not be liable for any misuse, improper operations, improper installation, improper maintenance, alteration, modification, accident or unusual degradation of the equipment or parts due to an unsuitable installation environment. No representation of other affirmation of facts, including but not limited to statements regarding capacity, suitability for use or performance of the equipment, shall be or be deemed to be a warranty or representation by ALTECH for any purpose, nor give rise to any liability or obligation of ALTECH whatsoever. Customer s sole and exclusive remedy in the event of breach of warranty, as set forth herein, is expressly limited to () the correction of the defect by adjustment, repair, modification, or replacement, or (2) issuance of a credit or refund of the purchase price for the defective equipment at ALTECH s election and sole expense. EXCEPT AS SPECIFICALLY PROVIDED IN THIS AGREEMENT, THERE ARE NO OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. THIS WARRANTY EXTENDS ONLY TO THE CUSTOMER FROM ALTECH OR ITS AUTHORIZED DISTRIBUTOR. LIMITATION OF LIABILITY - IN NO EVENT, SHALL ALTECH BE LIABLE FOR LOSS OF PROFITS, INDIRECT, SPECIAL, CONSEQUENTIAL OR OTHER SIMILAR DAMAGES ARISING OUT OF ANY BREACH OF THIS AGREEMENT OR OBLIGATIONS UNDER THE AGREEMENT. ALTECH SHALL NOT BE LIABLE FOR ANY DAMAGES CAUSED BY DELAY IN SHIPMENT, INSTALLATION OR FURNISHING OF EQUIPMENT OR SERVICES UNDER THIS AGREEMENT. No action arising out of any claimed breach of this Agreement may be brought by either party more than two (2) years after the cause of action has accrued. PATENT INDEMNITY - ALTECH shall defend or settle any suit or proceeding brought against Customer based on a claim that any equipment made to ALTECH design and furnished hereunder constitutes an infringement of any existing United States patent, provided (ALTECH) is notified promptly in writing and is given complete authorization and information required for the defense, and ALTECH shall pay all damages and costs awarded against Customer, but shall not be responsible for any costs, expense or compromise incurred or made by Customer without ALTECH s prior written consent. If any equipment is in ALTECH s opinion likely to or does become the subject of a claim for patent infringement, ALTECH may at its option and expense procure for Customer the right to continue using the device, modify it to become non-infringing, but in the event ALTECH is not reasonably able to modify, substitute, or otherwise procure for Customer the right to continue using it, ALTECH will remove such equipment and refund to Customer the amount paid in excess of a reasonable rental for past use. ALTECH shall not be liable for any infringement or claim based upon use of the equipment in combination with other equipment not supplied by ALTECH or with modifications made by Customer. The foregoing states the entire liability of ALTECH to Customer arising from patent infringement. SELLER S REMEDIES - Should Customer fail to make any payment within ten (0) days of its due date, or fail to perform any other of the Customer s obligation hereunder upon thirty (30) days written notice, or should Customer be or become insolvent or be a party to any bankruptcy receivership proceeding prior to full payment of all amounts payable hereunder, ALTECH may: (a) with or without demand or notice to customer declare the entire amount unpaid immediately due and payable; (b) enter upon the premises where the equipment may be found and remove it (Customer shall assemble the equipment and make it available to ALTECH at a place reasonably convenient to both parties and shall permit and assist ALTECH in effecting the retaking and removal of the equipment); and (c) sell any or all the equipment as permitted under applicable law, applying the proceeds of the sale to payment of the expenses of retaking, repairing and selling the equipment, reasonable attorney fees and to the satisfaction of all indebtedness then due and unpaid under this Agreement. Any surplus shall be paid to Customer and any deficiency shall be paid to ALTECH by Customer. The remedies provided herein shall be cumulative and in addition to all other remedies provided by law or equity or under the Uniform Commercial Code. GOVERNING LAW - This agreement will be governed by the Laws of the State of New Jersey. GENERAL - This Agreement shall only become effective and binding when either (a) it has been accepted and executed by an authorized representative of ALTECH, or (b) the equipment has been shipped to Customer, with or without acceptance in writing hereon. Notice of acceptance is hereby waived by Customer. Customer hereby acknowledges receipt of a true and complete copy hereof. No addition to or modification of any of the Terms and Conditions of Sale as they appear herein shall be binding upon ALTECH unless signed in writing by duly authorized representative of ALTECH in Flemington, N.J. Typographical and clerical errors in quotations, orders and acknowledgments are subject to correction. This Agreement is not assignable without the prior written consent of ALTECH. Any attempt to assign any of the rights, duties or obligations of this Agreement without such consent is void. If any provision or provisions of this Agreement shall be held to be invalid, illegal or unenforceable, the validity, legality and enforceability, of the remaining provisions shall not in any way be affected or impaired thereby. ALTECH is not responsible for failure to fulfill its obligation under this Agreement due to causes beyond its control, or except as agreed herein. THE CUSTOMER ACKNOWLEDGES THAT HE HAS READ THE AGREEMENT, UNDERSTANDS IT, AND AGREES TO BE BOUND BY ITS TERMS AND CONDITIONS. FURTHERMORE, THE CUSTOMER AGREES THAT IT IS THE COMPLETE AND EXCLUSIVE STATEMENT OF THE AGREEMENT BETWEEN THE PARTIES, WHICH SUPERSEDES ALL PROPOSALS OR PRIOR AGREEMENTS, ORAL OR WRITTEN, EXPRESSED OR IMPLIED, AND ALL OTHER COMMUNICATIONS BETWEEN THE PARTIES RELATING TO THE SUBJECT MATTER OF THIS AGREEMENT. 9 Altech Corp. 35 Royal Road Flemington, NJ P F

96 Here are other great products available from Altech! Smart Relays and Digital Timers supports up to 8 i/os (32 digital inputs & 6 digital outputs). DsT feature Available. Backlit lcd screen for display & modification of pre-selected parameters of functional blocks, viewing i/o status and programming on the device. PC software for programming, online & offline simulation, documentation & printing. Designed for use in automation for commercial & industrial sectors. modbus Communication. ul 508 (ul file No. E352868), iec and iec ~. 250 lines of ladder programming. 6 soft text messages, Time switches, Compare Counters, Timers, Counters & 2 analog functions. Contactors, Mini Contactors, Overload Relays and Manual Motor Starters Industrial Enclosures DIN Rail Power Supplies Contactors UL508 CSA C22.2 No. IEC & IEC /2HP up to 80V AC Direct Mounting Overload Relays Full line of accessories UL508 Type E Manual Motor Starters UL508 (Type E self-protected Manual Motor Controller) CSA C22.2 No. IEC & IEC Type F combination Manual Motor Controller (with MC-Series Contactor) Altech offers a broad selection of nonmetallic and aluminum Industrial Enclosures to meet your diverse design requirements. Sizes range from.97 x 2.05 x.38 to 35.3 x.8 x 5.59 inches. Materials include polycarbonate, polystyrene, polypropylene, ABS or aluminum. Polycarbonate and aluminum series have been recently expanded. Protection up to IP67 (NEMA, X). Smooth sidewalls or sidewalls with knockouts. Enclosures can be mounted directly onto a panel, frame or other mounting surfaces. EMI / RFI Coating is available. Competitive cover printing is available. Hinge Kits. Customization available. Altech DiN rail mountable power supplies have universal AC input. They are suitable for industrial and automation applications. ul508 listed or ul recognized. single and Three phases up to 960W. Outputs of 5V, 2V, 5V, 2V and 8V. Class 2 devices are available. installed on DiN rail Ts35/ 7.5 or 5. Protections of short circuit / Overload / Overvoltage / Over temperature. Cooling by free air convection. All-in-One DCuPs, battery based. ultra Capacitor DCuPs, no battery required. Worldwide approvals. 3 year warranty. Interface Modules and Power Supplies Altech offers a wide range of DIN Rail or panel mount cable interface modules, relay interface modules, power supplies, carrier modules, and custom designed modules. Cable to connector models include: D-Sub connectors, ribbon cable connectors, and Dip socket connectors to terminals. Standard relay modules from to 6 channels, and safety relay modules from to 6 channels and up to 0 poles are included. The catalog also contains switching power supplies, linear power supplies, and custom designed interface modules. Terminal Blocks Liquid Tight Strain Reliefs Altech offers a NEW Terminal Block catalog with the most competitively priced blocks in the industry. We feature screw and spring clamp models for DIN rail and panel mount applications. This advanced line of wire termination products will increase your design options and help to get the job done more efficiently. Our line of blocks include feedthrough (single, double or triple level), distribution, ground, fuse, disconnect, thermocouple, surge suppressor and indicator. A wide variety of accessories, tools and ferrules are available. This 6-page catalog introduces Altech s full line Liquid Tight Strain Reliefs (Cord Grips) which are used to seal cable entries, keep contaminant s from entering enclosures, provide strain relief and thus reduce stress on components and termination points inside enclosures. Available in standard, highperformance, and economy versions, functions include Straight-Through, Increased Strain Relief, Bend Protection, Pull/Bend Protection, Multi-conductor, Flat Cable and EMI/RFI. They can be used with almost any type of cable, cord or conductor - solid, stranded, flat, shielded, high temperature, etc. Motor Disconnect Switches Altech s line of Motor Disconnect Switches are listed as Manual Motor Controllers for AC Motor Starting Across-the-line and AC General use. This new 6 page catalog includes the 3 different handle designs, which are all available in gray/black or yellow/red housings. Electrical ratings are 25-50A / 600V. The switches are non-fused DIN Rail mountable. Neat features include: snap-on auxiliary switches, door mounting kit and a retrofit 30A fuse holder. Also featured are Enclosed Motor Disconnect Switches & Fused Enclosed Motor Disconnect Switch (30A) in plastic or stainless housings. UL 89 ANNEX Altech Corp. 35 Royal Road Flemington, NJ P F

Typical UL489 Application Power Circuit of a UL508A Panel

Typical UL489 Application Power Circuit of a UL508A Panel Altech UL489 Typical UL489 Application Power Circuit of a UL508A Panel Disclaimer: This is an application example. Installation should be done by a qualified electrician under the guidance of UL specifications..

More information

E s h o r t c ir c u it Wit h s t AND r At ing s f o r r -s er ies s u ppl ement Ar y pr o t ec t o r

E s h o r t c ir c u it Wit h s t AND r At ing s f o r r -s er ies s u ppl ement Ar y pr o t ec t o r UR-Series UL077 Recognized Supplementary Protector DIN Rail Mounted 7.5mm width per pole Thermal Magnetic 80Y/277V AC, 50/Hz 0kA Short Circuit Withstand Capacity Applications (on the load side of Branch

More information

Typical UL1077 Application

Typical UL1077 Application Altech UL77 Typical UL77 Application Control Circuit of a UL508A Panel Disclaimer: This is just an example application. Installation should be done by a qualified electrician under the guidance of UL/NEC

More information

Control Circuit of a UL508A Panel. Typical UL1077 Application

Control Circuit of a UL508A Panel. Typical UL1077 Application Altech UL077 Typical UL077 Application Control Circuit of a UL508A Panel Disclaimer: This is an example application. Installation should be done by a qualified electrician under the guidance of UL/NEC

More information

Altech UL508. Typical UL508 Application. Power Circuit of a UL508A Panel

Altech UL508. Typical UL508 Application. Power Circuit of a UL508A Panel Typical UL508 Application Power Circuit of a UL508A Panel Altech's V-EA UL508 Manual Motor Controllers are approved for Group Installations Disclaimer: This an application example. Installation should

More information

Altech UL1077/508 Busbar System

Altech UL1077/508 Busbar System Altech UL1077/508 Busbar System UL1077/508 Listed Busbars The Altech Busbar System is an innovative way to jumper up to 57 poles of Manual Motor Controllers (MMC) and Supplementary Protectors (SP). The

More information

Control Circuit Protection

Control Circuit Protection Contents 5SJ4 Branch Circuit Protectors 5SY4 Supplementary Protectors 5SY6 Supplementary Protectors 16/19 5SJ4 Page Selection and ordering data 1-pole up to 63A 16/4 1-pole, 2-pole, 16/5 3-pole, 240VAC

More information

UMBW-UL489 and UL1077 Listed

UMBW-UL489 and UL1077 Listed -UL489 and UL77 Listed Introducing the New WEG Series Thermal-Magnetic Miniature Breakers. This new offering includes both UL489 and UL77 approvals to provide a solution for circuit & equipment protection

More information

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers Series KTU7 UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s KTU7 series of UL Molded Case Circuit Breakers are UL489 and CE listed

More information

Series L9 UL489 Miniature Circuit Breakers

Series L9 UL489 Miniature Circuit Breakers Series L9 UL489 iniature Circuit Breakers Industrial Circuit Breakers for Branch Circuit Protection up to 63 Amps L9 Series B Circuit Breakers Series B L9 UL489 circuit breakers offer new features, expanded

More information

Protection Equipment. 5/2 Introduction

Protection Equipment. 5/2 Introduction Protection Equipment /2 Introduction SIRIUS 3RV2 Motor Starter Protectors/ Circuit Breakers up to 40 A /6 General data /12 For motor protection /14 For motor protection with overload relay function /1

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers Series UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s series of UL are UL489 and CE listed for global applications. The current

More information

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI . Technical Data and Specifications Ratings Frames EG, JG and LG EG JG LG Maximum rated current (amperes) 15, 160 1 50 400, 630 Breaker type 3 B B E S S H H C E S H C U X E S H C U X of poles 1, 3, 4,

More information

max pole for t=15 ms

max pole for t=15 ms Types RI 61 RI 61N RI 61J RI 62 RI 62J RI 63 RI 63N RI 64 single-pole single-pole + neutral pole single-pole (for DC circuits) two-pole two-pole (for DC circuits) three-pole three-pole + neutral pole three-pole

More information

1489-M Circuit Breakers

1489-M Circuit Breakers Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Terminal design helps prevent wiring misses Scratch- and solventresistant printing Suitable

More information

Selection Guide. Control Circuit and Load Protection

Selection Guide. Control Circuit and Load Protection Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866) .4 Miniature Circuit Breakers and Supplementary Protectors SPHM Supplementary Protector SPHM Supplementary Protector Product Description The SPHM Supplementary Protector is a dual rated product for both

More information

S200 UL 489 Series. Miniature circuit breakers S200. Features. Description

S200 UL 489 Series. Miniature circuit breakers S200. Features. Description UL 489 Series UL 489 Series Description The Series miniature circuit breaker offers a compact solution for protection requirements. The U AND UP devices are UL 489 tested limiting and DIN rail mounted.

More information

Thermal-Magnetic Circuit Breaker 201/-WA

Thermal-Magnetic Circuit Breaker 201/-WA Thermal-Magnetic Circuit Breaker 0/-WA Description Single pole thermal-magnetic circuit breaker with tease-free, trip-free, snap action mechanism and two button operation (M-type TM CBE to EN 60934). Featuring

More information

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

The breakers offer thermal-magnetic trip protection according to Z and K characteristics. Series High Performance Circuit Breakers Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific

More information

Bulletin 1489 Circuit Breakers. Selection Guide

Bulletin 1489 Circuit Breakers. Selection Guide Bulletin 1489 s Selection Guide Bulletin 1489-A Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable

More information

Series L9 UL-489 Miniature Circuit Breakers

Series L9 UL-489 Miniature Circuit Breakers Series UL-489 iniature Breakers Industrial Breakers for Branch up to 40 Amps Sprecher+Schuh includes a line of circuit breakers approved for branch circuit applications in the United States and Canada

More information

S200 UL 489 Series. Miniature Circuit Breakers. Description. Features

S200 UL 489 Series. Miniature Circuit Breakers. Description. Features S200 UL 489 Series Miniature S200 UL 489 Series Miniature Circuit Breakers Description The S200 Series miniature circuit breaker offers a compact solution for protection requirements. The S200U AND S200UP

More information

S200 UL 1077 Series S200. Supplementary protective devices. UL 1077 Series. Miniature. circuit breakers. S200 Supplementary protective devices

S200 UL 1077 Series S200. Supplementary protective devices. UL 1077 Series. Miniature. circuit breakers. S200 Supplementary protective devices UL 077 Series Supplementary protective devices The UL 077 Series miniature supplementary protector offers a compact solution for protection requirements. The devices are DIN rail mounted. The is available

More information

Product index. 4 - Manual motor protectors. Phone: Fax: Web: -

Product index. 4 - Manual motor protectors. Phone: Fax: Web:  - Product index -....1.3 Features and benefits...1 General information Suitable applications...2 -.3 Motor ratings... Pilot duty ratings and overload trip classes...5 Ordering details Type MS116...6 Type

More information

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077 Data Sheet System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077 2CDC021026S0011 2CDC021016S0012 The S 200 PR is a high-performance supplementary protector with

More information

Electronic Circuit Breaker ESS20-0..

Electronic Circuit Breaker ESS20-0.. Electronic Circuit Breaker ES-0.. Description Electronic circuit breaker type ES-0.. is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 4 V switch-mode

More information

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory

More information

PRICING. Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products. Class 600. October 2004

PRICING. Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products. Class 600. October 2004 PRICING October 2004 Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products Class 600 CONTENTS Description Page Multi 9 Supplementary Protectors and Miniature Circuit Breakers.............3

More information

and other modular devices for low voltage installation

and other modular devices for low voltage installation Technical catalogue System and other modular devices for low voltage installation 2CSC400002D0204 SUMMARY Introduction Miniature Circuit-Breakers Residual Current Devices Auxiliary elements and accessories

More information

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.

More information

Jtec 10kA Miniature Circuit Breaker

Jtec 10kA Miniature Circuit Breaker EN 60898 Jtec 10kA Miniature Circuit Breaker Techna s JTEC range has been enthusiastically adopted by a diverse range of customers seeking a cost effective 10kA performance. Jtec MCBs are available in

More information

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters

More information

Protection Equipment

Protection Equipment Protection Equipment Price Groups 101, 102, 121, 131, 143 /2 Introduction Motor Starter Protectors/ Circuit Breakers SIRIUS 3RV2 Motor Starter Protectors up to 40 A new /7 General data /13 For motor protection

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS MANUFACTURED IN THE EU EUROPEAN QUALITY 1, 2 & 3 POLE MCB s TRIPPING CURVES C & D CURRENT RATINGS 1AMP TO 63AMPS 10KA BREAKING CAPACITY

More information

Short form catalogue. Motor protection & control

Short form catalogue. Motor protection & control Short form catalogue Star Series Motor protection & control Motor Protection and Control up to 25 HP / 600 VAC Overview...2 Contactors and Overload Relays...11 4-pole Contactors...41 Control Relays...59

More information

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4. Product index -....1.3 Features and benefits...1 General information Suitable applications...2 -.3 Motor ratings... Pilot duty ratings and overload trip classes...5 Ordering details Type MS116...6 Type

More information

US CATALOG. Miniature circuit breakers

US CATALOG. Miniature circuit breakers US CATALOG Miniature circuit breakers Table of contents 004 024 S(U)200 series miniature circuit breakers UL 489 series 025 048 S200 series miniature circuit breakers UL 1077 series 049 056 Application

More information

1492-CB 1492-GH 1492-GS

1492-CB 1492-GH 1492-GS 1 The Allen-Bradley Line of Devices Allen-Bradley offers 3 different lines of Circuit Breakers (Supplementary Protectors) and a line of branch circuit rated Fuse Holders. Allen-Bradley Thermal Magnetic

More information

Jtec 489 UL489 Branch Circuit Breaker

Jtec 489 UL489 Branch Circuit Breaker Jtec 489 UL489 Branch Circuit Breaker 10kA Miniature Circuit Breaker R The Jtec 489 range is UL 489 listed (File E255530). Available in trip curves Z (v. quick), B (quick), C (medium), K (motor) and D

More information

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up

More information

Motor Circuit Breakers C4

Motor Circuit Breakers C4 Motor protection rating up to 100 Amps Short circuit breaking capacity up to 100kA Phase failure protection DIN rail mounting Wide range of accessories Options and ordering codes Model C4/32T Setting Short

More information

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when

More information

22AF 40AF AF 150AF 225AF 400AF 800AF

22AF 40AF AF 150AF 225AF 400AF 800AF Contactors MC-Series UL508 E108780 Contactor 3 Pole Standards and Certifications UL508 IEC 60947-2 & IEC 60947-4-2 CSA C22.2 No.14 Features 8 Frame Sizes 1/2HP up to 600HP @ 480V AC Screw Terminals (Lug

More information

Circuit Protection. Circiut Protection

Circuit Protection. Circiut Protection Circuit Protection Series L8 UL1077 Supplementary Protectors...2 Selection Guide - Trip Curve "B"...4 Selection Guide - Trip Curve "C"...5 Selection Guide - Trip Curve "D"...6 Accessories...7 Technical

More information

F-Series. Circuit Breaker

F-Series. Circuit Breaker F-Series Circuit Breaker The F-Series hydraulic/magnetic high amperage circuit breakers are designed to handle high current applications in extremely hot and/or cold locations. Due to its timeproven hydraulic/magnetic

More information

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD. DATASHEET - DILMC9-10(24VDC) Technical data General Contactor, 3p+1N/O, 4kW/400V/AC3 Part no. DILMC9-10(24VDC) Catalog No. 277468 Eaton Catalog No. XTCEC009B10TD EL-Nummer 4110305 (Norway) Standards IEC/EN

More information

ASL09..S 3-pole Contactors - Spring Terminals

ASL09..S 3-pole Contactors - Spring Terminals 4 kw 5 hp ASL09..S 3-pole Contactors - Spring DC Operated Description - 3-pole contactors with spring terminals, - N.C. or N.O. built-in auxiliary contact, - Low coil consumption, - Polarity on the coil

More information

G-Series. Circuit Breaker.

G-Series. Circuit Breaker. -Series Circuit Breaker Carling Technologies -Series hydraulic/magnetic circuit breakers offer the highest quality solution to your circuit protection requirements. The -Series is designed to sense over-current

More information

MCBs and accessories are certified under CSA C22.2 No. 235 per File LR Tripping characteristics

MCBs and accessories are certified under CSA C22.2 No. 235 per File LR Tripping characteristics Miniature circuit breakers General information General information Miniature circuit breakers (MCBs) are used throughout the world in all types of electrical installations. ABB MCBs are recognized for

More information

F-Series. Circuit Breaker

F-Series. Circuit Breaker F-Series Circuit Breaker The F-Series hydraulic/magnetic high amperage circuit breakers are designed to handle high current applications in extremely hot and/or cold locations. Due to its timeproven hydraulic/magnetic

More information

Magnetic Overcurrent Circuit Breaker

Magnetic Overcurrent Circuit Breaker Magnetic Overcurrent Circuit Breaker 808-... Description ngle pole miniaturised magnetic circuit breakers with unique highspeed operating mechanism and push/pull on/off manual actuation. Fitted with electrically

More information

Pro M Miniature Circuit Breakers S260, S270, S280, S290. System Pro M. Description

Pro M Miniature Circuit Breakers S260, S270, S280, S290. System Pro M. Description Miniature Circuit Breakers S260, S270, S280, S290 Description The S2 Series of miniature circuit breakers offer a compact solution to protection requirements. The breakers are recognized under standard

More information

US CATALOG. Miniature Circuit Breakers

US CATALOG. Miniature Circuit Breakers US CATALOG Miniature Circuit Breakers Miniature circuit breakers Table of contents S(U)200 series miniature circuit breakers UL 489 series Description and features 2 SU200M-C 3 SU200M-K 4 SU200M-Z 5 SU200MR-K

More information

TMC 91H is now TMC 60 C Series

TMC 91H is now TMC 60 C Series TMC 91H is now TMC 60 C Series The new Thermal Magnetic Circuit Breaker is once again available and better than ever! The new version is not only UL recognized with the same electrical performance as the

More information

Siemens AG Price groups PG 14O, 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J

Siemens AG Price groups PG 14O, 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J Protection Equipment Siemens AG 2015 Click on the Article No. in the catalog PDF to access it in the Industry Mall and get all related information. Article-No. 3RA1943-2C 3RA1943-2B 3RA1953-2B 3RA1953-2N

More information

Miniature Circuit-Breakers (MCBs)

Miniature Circuit-Breakers (MCBs) Product Overview Miniature Circuit-Breakers (MCBs) Design Tripping characteristics Rated current I n Rated breaking capacity Power supply company product range 5SP3 E 16 - A Standard product range 5SQ2

More information

4 - Miniature controls

4 - Miniature controls Index -....1.22 Selection Contactors for connection to PLCs, B6S & B7S, 3 phase...6 Contactors, Interface, B6 & B7, 3 phase...5 Contactors, features...1 Contactors, mechanically interlocked, B6 & B7, 3

More information

The Widest Range of Altech Products Available

The Widest Range of Altech Products Available } 1 The Widest Range of Altech Products Available thinkallied.com 1.800.433.5700 } Make Allied your one-stop shop for complete industrial automation solutions from Altech Powerful Solutions for Industrial

More information

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories Manual motor protectors Manual motor protectors Manual motor Protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certified

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G V

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G V Description Single and two pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast magnetic only or hydraulically delayed switching characteristics

More information

BETA Switching Switches and Light Indicators

BETA Switching Switches and Light Indicators Siemens AG 2008 BETA Switching /2 Product overview /3 5TE8 control switches / 5TE4 pushbuttons /2 5TE5 light indicators /5 5TE8 ON/OFF switches /22 5TE9 busbars /24 5TE switch disconnectors Siemens ET

More information

DX³ RCCBs - ID 4P up to 100 A

DX³ RCCBs - ID 4P up to 100 A 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ s - ID CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

Miniature Circuit Breakers

Miniature Circuit Breakers S00 Series Miniature S00 Series Miniature Circuit Breakers Description The S00 Series miniature circuit breaker offers a compact solution for protection requirements. The S00 devices are UL tested limiting

More information

...at Altech, of course!

...at Altech, of course! FANTASTIC approved FERRULES...at Altech, of course! Approved for the US & Canadian Market Other great Altech CSA approved products: Miniature Circuit Breakers / Manual Motor Controllers DIN Rail and Panel

More information

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101404D0201 24/03/11-30-10-.. / Z-30-10-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

IP20 degree of protection; IP40 degree of protection after installation in a distribution box

IP20 degree of protection; IP40 degree of protection after installation in a distribution box RI 50 RI 50 is used for the protection of installations and devices (overload and short circuit), and as a disconnector in case of electric shock Simple and quick fixing to a 35 mm mounting rail in accordance

More information

Meta Solution. Contactors and Overload relays

Meta Solution. Contactors and Overload relays Meta Solution Contactors and Overload relays Meta Solution New generation of Contactors from LSIS Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol series

More information

MCBs S260 S290. Pro M Miniature Circuit Breakers S260, S270, S280, S290. System Pro M. Description. Features

MCBs S260 S290. Pro M Miniature Circuit Breakers S260, S270, S280, S290. System Pro M. Description. Features Miniature Circuit Breakers S260, S270, S280, S290 S260 S290 MCBs Description The S2 Series of miniature circuit breakers offer a compact solution to protection requirements. The breakers are recognized

More information

209 Series. Magnetic Circuit Protectors

209 Series. Magnetic Circuit Protectors 29 Series Magnetic Circuit Protectors Introduction 249 Power Selector System Multi-Pole Configurations Operating Characteristics Delay Curves Specifications Decision Tables 73 75 77 79 8 82 85 87 29/29/229/249/279

More information

Selection Guide Motor Control Device Solutions

Selection Guide Motor Control Device Solutions Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements

More information

DC-UPS INTRODUCTION SOME OF THE MANY APPLICATIONS:

DC-UPS INTRODUCTION SOME OF THE MANY APPLICATIONS: Since 984, Altech Corporation has grown to become a leading supplier of automation and industrial control components. Headquartered in Flemington, NJ, Altech has an experienced staff of engineering, manufacturing

More information

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data B6, B7, BC6, BC7, TBC7 - and 4-pole mini contactors VB6, VB7, VBC6, VBC7 - and 4-pole mini reversing contactors Main pole Utilization characteristics according to IEC Standards IEC/EN 60947-1, IEC/EN 60947-4-1

More information

Essential equipment for all your requirements

Essential equipment for all your requirements NEW CTX CONTACTORS Essential equipment for all your requirements 9 A TO 310 A THREE-POLE INDUSTRIAL CONTACTORS CTX three-pole industrial contactors, a sense of family The new range of CTX contactors provides

More information

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated VB6, VB7 -pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated VB7-0-10 2CDC211006F0011 Description VB6, VB7 -pole compact design reversing contactors are space optimized control

More information

209/219/229/249/279 Series Magnetic Circuit Protectors

209/219/229/249/279 Series Magnetic Circuit Protectors 29/29/229/249/279 29/29/229/249/279 Series Magnetic Circuit Protectors Introduction 65 249 Power Selector System 67 Multi-Pole 69 Configurations 7 Operating Characteristics 73 Delay Curves 74 Specifications

More information

Product Line Overview. The Most Logically Designed Contact Assembly

Product Line Overview. The Most Logically Designed Contact Assembly Circuit Breakers & Supplementary Protectors 15 00 Amperes for UL, CSA & IEC Applications Product Line Overview -3 General Information Cutler-Hammer Series G Molded Case Circuit Breakers provide increased

More information

AP/UP, AP/MIL Series Magnetic Circuit Protectors

AP/UP, AP/MIL Series Magnetic Circuit Protectors AP/UP, AP/MIL AP/UP, AP/MIL Series Magnetic Circuit Protectors Introduction 68 Single Pole 69 Multi-Pole 70 Configurations 72 Operating Characteristics 73 Delay Curves 74 Specifications 75 Decision Tables

More information

DX³ 4-pole RCBO 6000 A/10 ka

DX³ 4-pole RCBO 6000 A/10 ka 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ 4-pole RCBO CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

Controls. CONTACTORS CWB Line (up to 40A)

Controls. CONTACTORS CWB Line (up to 40A) Controls CONTACTORS CWB Line (up to 40A) 0800 367 934 Contactors CWB Line (up to 40A) CONTACTORS CWB Line (up to 40A) Summary New WEG CWB Contactors 4 The Technology Within 6 Energy Savings 7 Easy Panel

More information

Thermal Circuit Breaker 3120-F...

Thermal Circuit Breaker 3120-F... Description The 320 circuit breaker/switch combination is an ON/OFF switch with integral overcurrent protection (S-type TO CBE to EN/IEC 60934). The trip element is a bimetal. Type 320 is ideally suited

More information

ELFA E90S MINI BREAKERS

ELFA E90S MINI BREAKERS ELFA E90S MINI BREAKERS ELFA E90S SERIES UL Approved (UL1077) 10KA INTERUPTION CAPACITY OPTIONS FIELD KITS Auxiliary Contacts Alarm Contact Shunt Trip UV Trip Current Limiting Design (Class 3) 3 Different

More information

Basic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors

Basic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors MOTOR STARTERS SM Basic function Switching and protection of motors up to A Protection against short-circuit and protection against overload The device responds to phase failure The device is provided

More information

Star Series Motor protection & control

Star Series Motor protection & control Contact us ABB Inc. Low Voltage Control Products 16250 W. Glendale Drive New Berlin, WI 53151 Phone: 888-385-1221 Fax: 800-726-41 USA Technical support & Customer Service: 888-385-1221, Option 4 7:30AM

More information

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certifi ed for

More information

Data Sheet Molded Case Circuit Breakers Molded Case Motor Circuit Protectors Molded Case Switches Ex9 Series - M

Data Sheet Molded Case Circuit Breakers Molded Case Motor Circuit Protectors Molded Case Switches Ex9 Series - M Data Sheet Molded Case Circuit Breakers Molded Case Motor Circuit Protectors Molded Case Switches Ex9 Series - M MS50T3L M2N200T3L na.noark-electric.com NOARK Ex9 Series - M Features Molded Case Circuit

More information

FMotor Circuit Controllers

FMotor Circuit Controllers Technical Information Motor Circuit Controller IEC Performance Data Catalog Number KTA7-25S...32S 0.16A 0.25A 0.4A 0.63A 1A 1.6A 2.5A 4A 6.3A 10A 16A 20A 25A 29A 32A Rated Operational Current, I e [A]

More information

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP Soft Starter Three-Phase Scroll Compressor Soft Starter Types RSBD Soft starting of 3-phase scroll compressors up to 95Amp Patented auto-adaptive algorithm for optimum inrush current reduction (No user

More information

Phone: Fax: Web: -

Phone: Fax: Web:  - HK1-11 HKF1-11 HK-11 HKS-20 uxiliary contacts Mounting uxiliary contacts position Pilot duty rating Instantaneous Lagging / leading / max. 116 132 5x 9x quantity ac dc NO NC NO NC 2 - - - HK1-20 Right

More information

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals NSL..S 4-pole / 8-pole Contactor Relays - Spring DC Operated Description - 1-stack contactor relays: 4-pole, - 2-stack contactor relays: 8-pole, - Mechanically linked contact elements available, - Low

More information

Technical Data. Miniature circuit-breakers for branch circuit protection according to UL 489, CSA C 22.2 No. 5

Technical Data. Miniature circuit-breakers for branch circuit protection according to UL 489, CSA C 22.2 No. 5 Technical Data Miniature circuit-breakers for branch circuit protection according to UL 489, CSA C 22.2 No. 5 When connecting aluminum conductors, ensure that the contact surfaces of the conductors are

More information

Miniature Circuit Breaker

Miniature Circuit Breaker Introduction - Miniature Circuit Breaker (MCB) SALIENT FEATURES SALIENT FEATURES Standards MCBs conform to the latest standard IS 8828: 1996/IEC: 898 1995 Mid-Trip Position The Mid trip position of the

More information

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489 MINIATURE CIRCUIT BREAKERS SU200M Datasheet Branch protection acc. to CSA C22.2 No.5 / UL 489 The miniature circuit breaker SU200 M is ABB s solution for UL 489 branch circuit protection up to 480 Y/277

More information

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Thermal-magnetic Miniature Circuit Breaker 4230-T... Thermal-magnetic Miniature Circuit Breaker 40-T... Description Single pole and multipole thermal-magnetic miniature circuit breakers (MCBs) in accordance with EN 60947-, UL 1077 and UL 489 for DIN rail

More information

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL ed and

More information

Thermal-Magnetic Circuit Breaker M1-...

Thermal-Magnetic Circuit Breaker M1-... Thermal-Magnetic Circuit Breaker 320-...-M-... Description Two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 6034). The addition of a magnetic tripping

More information

3VU13, 3VU16 Circuit-Breakers

3VU13, 3VU16 Circuit-Breakers 3VU3, 3VU6 Circuit-Breakers Description The 3VU3, 3VU6 circuit-breakers are compact circuit-breakers for currents up to 80 A which operate according to the current limiting principle. The devices are used

More information