Digital II Pressure Control System

Size: px
Start display at page:

Download "Digital II Pressure Control System"

Transcription

1 SU64235 July 2003 Aerospace Group Conveyance Systems Division Applicable addition manuals: IN64235 IN IN64108 IN IN64802 Carter Ground Fueling Setup & Calibration Manual Digital II Pressure Control System Model 64235

2 TABLE OF CONTENTS PAGE 1.0 INTRODUCTION EQUIPMENT DESCRIPTION TABLE OF OPTIONS AND ORDERING INFORMATION QUICK REFERENCE/SUMMARY OVERVIEW OF CONTROL MODULE NAVIGATING THE MENU SYSTEM MENU TREE FUNCTIONS SETUP CALIBRATION CONFIGURATION TROUBLE SHOOTING & ERROR CODES

3 Setup & Calibration Instructions Carter Model INTRODUCTION Digital II lectronic ressure control system is the follow on to Eaton s original Model System. The digital system offered by Eaton provides the most accurate system for controlling pressure at the aircraft without the use of often difficult to setup venturis. It can be used on either a refueler or on a hydrant servicer/cart. All the normal attributes of a hydro-mechanical pressure control system are present in Digital II with greater accuracy of control including surge pressure. All of this is accomplished without the need for air pressure and its problems. 2.0 EQUIPMENT DESCRIPTION The new and improved Carte Digital II Pressure Control System combines two well-known technologies, as did the original The combination of hydro-mechanical valving and a microprocessor eliminates the need for air reference pressure, servo controls or springs to control pressure. Fuel cannot leak into the air system such as occurs regularly in the industry standard air reference system. Adjustments for pressure control, rate of flow control, opening and closing times are easily accomplished during the setup process using a hand-held device. Once the system is setup the hand-held device is unplugged from the system and stored away for future use. Only one hand-held device is required per airport location or system per vehicle (two if a vehicle has two systems). Once the calibration unit has been removed the operator cannot make any changes to the parameters previously setup. An improvement from the original system is the absence of buttons, key locks or switches on the face of the unit. The digital system eliminates the need for the use of air and all of its components, including compressors, air tanks, dryers, regulators, gauges and all the associated fittings, valves and tubing not to mention the labor needed to install them. It also eliminates the need for a venturi from the system with its confusion in adjustments. When used on a hydrant servicer only one fuel line is required from the vehicle to the coupler versus the twin hoses required on air reference systems. 3.0 TABLE OF OPTIONS AND ORDERING INFORMATION The basic part number for the Digital II System for ordering purposes is This part number provides one with the module that is mounted onto the vehicle. There are no options associated with the new Digital II. It is weather proof with improved casing and panel display covering. There are certain special test items needed as described in section 4.0 below to setup the unit and to perform the calibration. Other components that may be desired or needed are described below ** Transducer. The ** should be replaced with the length of connecting cable desired. Cable is available in lengths of 5-50 lengths in increments of 5. Specify for example for a 15 cable length Solenoid Valve Block Specify 64102A for 12 VDC or 64102B for 24 VDC applications. This is used with a digital coupler on a hydrant servicer application only Digital Coupler Used to mate to air operated API/IP Hydrant Valves. A whip hose is used to connect the coupler to the air port on the hydrant. The hose is not needed on manually operated hydrant valves. 3

4 Digital Coupler Same as except for smaller control head. Mates same hydrant valves / In-line Control Valve for refueler operation. Specify option A for 12 VDC or B for 24 VDC applications / By-pass Control Valve for refueler operation. (Option A 12 VDC, B 24 VDC applications.) 64050/ In-line Control Valve for refueler operation. (Option A 12 VDC, B 24 VDC applications.) 64060/ By-pass Control Valve for refueler operation. (Option A 12 VDC, B 24 VDC applications.) Remote Display for Digital II. This allows for display of flow rate and pressure at a place other than where the control module is mounted, e.g. a lift platform. Meter Pulser The system requires the ability to read the pulses from the meter. Carter does not provide this item but it can be obtained from any Veeder Root distributor. Carter recommends part number with its mounting kit part number Any brand pulser that produces pulses from pulses per gallon/liter can be used, however if one that produces less than 100 pulses the unit will have to be calibrated as noted herein. 4.0 QUICK REFERENCE/SUMMARY 4.1 Definition s Reset This term as used as part of the instructions refers to the resetting of the module. Turning the power off to the control module and then turning it back on may accomplish it. On most refueling equipment the power will be turned off to the control module when the refueling equipment is returned to the road condition. For example all of the nozzles stowed, the pump disengaged and the brakes released. System Reset or Power on Reset - It is possible to restore the system back to the factory or default setup, calibration and configuration settings. With the hand held unit connected to the control module and the rotary switch in the Modify position push the UP and DOWN buttons simultaneously. This will ERASE ALL PREVIOUS USER SETTINGS, and replace them with the original factory (default) setting. While this procedure will bring the unit back to a known baseline, it is NOT recommended that this unit be used to service aircraft, until the Setup, Calibration and Configuration procedures are once again performed to completion. 4.2 System Components The following components are required to setup and calibrate the system: Digital II Control Module properly installed on a refueler or hydrant servicer/cart in accordance with IN64235 Installation Instructions. This should include all components associated with the system as defined in the manual Hand-Held Device used to perform set up and calibration. This item is purchased separately and at least one unit is required for each location (airport). One such device is needed for each Digital II System on a single vehicle to be setup. Therefore if the vehicle happens to have two Digital II Systems then two handheld devices are needed Nozzle Transducer/Cable Assembly also needed for calibration of the system at the test facility Remote Display This item may or may not be present in any system at the customer s option. A pulser on the meter of the vehicle to provide the flow information to the unit. See paragraph 3.0 above for details. 5.0 OVERVIEW OF CONTROL MODULE The fro nt pa nel di splay is sho wn i n Fi gure 1 bel ow. The visible displays shown o n the p anel a re a s follows: 4

5 1. FLOW RATE The rate of flow experienced during refueling or test will be displayed in this area. 2. The indicator lights to the right of the FLOW RATE display will illuminate the unit of measure setup. The factory default is GPM. 3. PRESSURE The pressure at the aircraft (as calibrated and converted from the transducer to compensate for the system pressure loss between it and the aircraft) will be displayed here. 4. The indicator lights to the right of NOZZLE PRESSURE will illuminate the unit of measure setup. The factory default is PSI. 5. ACTIVE NOZZLE Indicator lights 1-6 will illuminate the to indicate the active nozzle (s) currently used or not stowed properly. 6. NORM The control module can be programmed to support two user selected refueling pressure settings, referred to as NORMAL and OVERRIDDEN. When illuminated this NORM indicator shows that the NORMAL refueling pressure setting is selected. 7. OVRRD This indicator, when illuminated, shows that the OVERRIDDEN refueling pressure setting is selected 8. MODIFY This lights up when the Hand-held Device is connected and is set to the Modify position. 9. SOLENOIDS The lights labeled A and B will normally flash continuously to mirror the electrical signal has been applied to operate the A and B solenoid valves on the controlling valve (in-line or by-pass) or for a coupler. 10. WATCHDOG - This light is normally off. It is there for a future addition of a new feature. 11. The amber light on the top right of the enclosure goes on in a steady fashion when the deadman is activated. It will flash when a deadman timeout is imminent. 12. This switch is used to switch between the two possible user programmed refueling pressure control settings, NORMAL or OVERRIDDEN. Pressing and holding for a couple of seconds will switch between the NORM indicator light (6) for the NORMAL setting or the OVRRD indicator light (7) for the OVERRIDEN setting. 5

6 13. The displays that are shown in either of the two panels (1) or (3) are designed to display numbers hence when letters are displayed they will be unusual in shape. The following table illustrates the various displays, both numbers and letters that one will see: 6.0 NAVIGATING THE MENU SYSTEM WARNING! Connecting the cable assembly between the Hand-Held Device and the Control Module when the power is ON can damage the Hand-Held Device and the Control Module. The Hand-Held Device has been provided in two configurations. The original one has a plastic case, a rotary switch, the connector for the transducer on the face of the unit and touch plate buttons for the arrow buttons. The later unit (serial number 200 and subsequent) has a metal case, a two-position toggle switch, button switches for the arrow keys and the connector for the transducer on the edge of the part. Both work equally well. The steps below will refer to the later design but both function in the same manner. The only difference is mainly in the switch. The rotary switch has more than two positions hence one will have to be certain that the switch is set to one of the two positions indicated and not to a dead position. Navigating the menu system is accomplished as follows: Turn off the power to the control module. If there is a master switch on the vehicle one can turn it off as well. With the power off, both display panels (1) & (3) above will be blank and all indicator lights will be out. Connect the cable furnished with the Hand-Held Device to both the handheld device and the control module (to the RS232 port on the bottom of the module). The 25 cable furnished with the Test Rig Transducer/Cable Assembly is used for this purpose. Apply power to the system. Remove one of the nozzles from its stowage point. Observe the corresponding active nozzle indicator light (5) is illuminated. The calibration to be performed in the following steps will apply to this particular nozzle/hose. Set the Toggle (or rotary) Switch on the hand-held device to the MODIFY position. This will allow one to review the menu options as noted below. Pushing the left arrow button will ALWAYS take one to the main program menu. Pushing the right arrow button will ALWAYS display the NEXT BRANCH of the menu tree. 6

7 The up arrow and down arrow are used to CHANGE the settings and on some occasions the down arrow button will be used to open a sub menu within the menu tree. Use the MENU TREE display shown in the next pages in two formats. They are setup as separate pages so they can be removed from the document and used on site. Once the calibration as noted below is completed put the toggle (or rotary) switch in the OPERATE position. Disconnect the Hand-Held Device from the system and store it along with the cable assembly away until needed. The transducer should be left installed in the test rig. 7.0 MENU TREE FUNCTIONS There are three basic functions that have to be accomplished before the system is ready to operate: SETUP The first step is used to set some of the basic functions of the system including opening and closing times, units of measure for the displays, flow limits for the nozzles and system and the deadman timer. One other function, Throttle Control is not functioning and is intended for future use only. CALIBRATION This step is used to calibrate the vehicle meter pulser to assure a proper flow rate. It is also used to calibrate the test rig and vehicle transducers and to set the pressure (s) at which the system will control. CONFIGURATION This step is important in that it assigns the various nozzles to a pulser if there is more than one pulser used on the vehicle. It also is used to assure that the system is set for either a refueler or hydrant servicer application. There are several other functions relating to use with auxiliary devices such as a remote beacon or a warning buzzer. Also some future additions that relate to monitoring the filter-separator or filter-monitor pressure differential are included but not functioning at this time. To perform the SETUP, CALIBRATION and CONFIGURATION process, connect the Hand-Held Device to the control module as outlined above. Once connected turn the power on. Turn the Hand-Held Device switch to MODIFY position. Remove the nozzle that is to be calibrated from its stowage. Observe the corresponding ACTIVE NOZZLE light on the control module is illuminated. Note that the following set-up, calibration and configuration process applies only to this nozzle. For setting any additional nozzles, the same process has to be performed on each. When performing the nozzle SETUP, CALIBRATION and CONFIGURATION process, only the nozzle that is being set should be removed from its interlock. All other nozzles are to remain in stowage. If more than one nozzle is removed from stowage, both displays will go blank and no other modifications will be allowed until the errant nozzle is stowed. 8.0 SETUP While power is required to modify any settings on the Control Module, it is not necessary to actually be connected to the flow rig nor flow fuel for the SETUP part of the complete setup. In fact when the system is in this mode it is not possible to actually flow. Use the following to setup the system: OPENING TIME Set the menu display to indicate OT (opening time). The system opening time is expressed as a percentage of a given time span. For example to speedup the opening time, change the number to a smaller number on the display. Use the up and down arrow buttons to raise or lower the value displayed. A setting of 0% = 5 7

8 seconds and 100% = 10 seconds. Factory default is 50%. Closing Time - Set the menu display to CT. As with opening time setting the closing time is a percentage of a given range, 0% = 2 seconds and 100% = 5 seconds. As before use the up or down arrow buttons to achieve the desired closing time. Factory default is 50%. FLOW UNITS Set the display to indicate FLO UNIT. This is used to select one of the three available units of measure for the flow rate display. While observing the indicator lights (2 on the front panel figure above), use the down arrow button to rotate through the available options. When the right selection is determined press the right arrow button to confirm the selection. Factory default is gpm. PRESSURE UNIT Set the menu display to indicate PRESS UNIT. This is used to select the units of measure that will display the pressure during operation. While observing the indicator lights (4 on the front panel figure above), use the down arrow button to rotate through the three options. When the proper selection is determined press the right arrow button to confirm the selection. Factory default is psi. NOZZLE FLOW LIMIT Set the display to indicate FL. This is used to set the flow limit for each nozzle. It is possible to set the flow limit for each of six nozzles. Remove the nozzle to be set from its stowage point. It is not necessary to connect the nozzle to an adapter. After the setting is complete restow the nozzle. Use the up and down arrow buttons to set the maximum rate of flow for each nozzle that is to be used. Normally in some operations two nozzles may be used simultaneously, e.g. two deck hoses. In this case, flow rate at two times the lower of the two set nozzle flow limits will be allowed to flow pass the control valve. And under all circumstances, the system would limit the total flow rate to below the SYSTEM FLOW LIMIT set in the next step. The factory default is set at 1500 gpm to make sure that there is no limitation to flow unless one desires one. SYSTEM FLOW LIMIT Set the menu display to SFL. This is used to set the CUMMULATIVE FLOW LIMIT for the system. During a refueling operation the system will use the lowest of this limit and the combined nozzle flow limit for the particular nozzle(s) in use. This function is mainly intended to be used to protect the filter elements and the meter from exceeding their recommended limits. Therefore it is recommended that the system limit be set to the limit for such devices. The individual nozzle flow limit settings can then be set for the desired limit without regard to protecting the equipment. For example, if a filter is rated for 1,000 gpm. The system limit should be set for the 1,000 gpm and each nozzle (deck hoses mainly) can be set for any flow rate desired. If they are set for 600 gpm each and are used where 1,200 gpm is possible the system setting will limit the system to the 1,000 and not the 1,200. The factory default for this function is again 1500 gpm. DEADMAN TIMER Set the menu display to DL. This is used to turn on and set the deadman timeout function. Use the up or down arrow buttons to set the number of minutes that the system will stay in operation before the operator is required to cycle the deadman. Set the display to zero if this function is not desired. If the vehicle is equipped with an overwing nozzle it is recommended that this function be set to zero. The factory default is off or zero. The deadman timeout function can be set from 0 (off) to 10 minutes for each nozzle. If different times are set for different nozzles the lowest setting will prevail. Deadman Timer is to prevent the operator from tying or otherwise keeping the deadman activated without actually holding it. Once the set time has been reached the operator will have 30 seconds to release and reactivate the deadman or the system will close. THROTTLE CONTROL The menu item is for future assignment only and is not working. 8

9 FIGURE 2 NAVIGATING THE MENU TREE 9

10 Use the right arrow button to scroll through the menu as shown in Figure 1. Use the up or down arrow buttons to change the data in any of the displays. FIGURE 2 - DIGITAL II MENU DIAGRAM Shows sampling of what will be shown in the display windows.

11 9.0 CALIBRATION In a flow vehicle which uses a dual control systems (such as an Bypass Valve for Primary and Inline Valve as Secondary), it is necessary to fail one of the systems to full open position while calibrating the other and vise versa. The system not in the process of being calibrated can be failed full open by placing it in the PULSER 1 CALIBRATION mode as below and proceed with normal calibration on the other. If the nozzle to be calibrated is equipped with an HECV (Hose End Control Valve), it is essential that the HECV is secured and fully engaged with the block out device in the calibration process. During this procedure it is required that the vehicle be connected to either a test rig or be set up to recirculate fuel. In both cases the Test Transducer/cable Assembly has to be installed in the simulated aircraft pressure port (the place one wants the system to control the pressure). This can be just downstream of the simulated aircraft adapter (the most accurate determination of pressure at the wing or in the nozzle port. In the latter case the pressure drop of the nozzle/adapter combination penalizes one. In addition the nozzle port does not provide a smooth measuring point for pressure determination. For this reason Carter recommends that the transducer be installed in a straight length of pipe either upstream of the nozzle or downstream of the recirculation adapter (the best choice). The system is designed for use with two meters simultaneously hence there are two pulser calibration steps. If only one pulser is used the second one can be skipped. Press the right arrow to CALIBRATION and then the down arrow to: PULSER 1 CALIBRATION The display will show as PLSR CAL 1. If the system has two pulsers select a nozzle that is assigned to pulser 1. Activate the deadman switch to start flow. Observe the flow meter on the test rig and time it with a stopwatch to determine the actual flow rate. To obtain the most accurate pulser calibration, use the flow control valve at the simulated aircraft adapter to adjust the flow rate to nominally used value, that is from 500 to 600 gpm. Then us the up or down arrows to adjust the flow rate being displayed to match the actual flow rate calculated. PULSER 2 CALIBRATION This step is only needed should the system have two pulsers (meters). Pushing the right arrow will move the display to PLSR CAL 2. Select a nozzle that is associated with pulser 2 and repeat the step outlined for pulser 1 above. The purpose of the next two steps is to calibrate the transducers on the rig and the vehicle. It is necessary to apply a known pressure to both of the transducers. A gauge should be installed adjacent to and upstream of the transducer in both instances. It is recommended that a ball valve be installed upstream of the transducers with a tee in the line to a gauge. In the case of the vehicle the gauge can be removed if desired and the leg of the tee plugged for operation. A pressure range of psi is recommended for the gauge. The Test Rig Transducer/ Cable is connected to the connector on the Hand-Held Device before starting this step. Static pressure can be applied to the transducers in several ways. The simplest way on a refueler is to lockup the pressure in the system and close the ball valve upstream of the transducer. To accomplish this set the Hand-Held Device toggle (or rotary) switch to the OPERATE mode. Activate the deadman and allow fuel to flow through the system. Close the valve downstream of the recirculation adapter and then release the deadman. Be sure that the pressure so trapped in the system is between 50 and 75 psi. 11

12 A similar way can be used to trap pressure in the system for a hydrant servicer by flowing, cl osing the t est rig va lve downstream of the tran sducer, relea sing the deadman and then clo sing the hyd rant coupler. Then re-place the Hand-Held Device toggle (or rotary) switch to the MODIFY mode and scroll down the calibration menu tree to the PRESSURE TRANSDUCER 1 CALIBRATION mode as follows. Note that in the pressure transducer calibration mode, no flow is possible even when the Deadman is applied. PRESSURE TRANSDUCER 1 CALIBRATION This step is used to calibrate the vehicle-mounted transducer. Set the menu to indicate PT1. Establish a system pressure as noted above or in some other manner then use the up or down arrows to adjust the value on the display to that equal to that on the gauge. If a negative pressure is indicated on the display during this test or in the one that follows, refer to section When calibrating the pressure transducers (system set for MODIFY) activating the deadman will not allow flow of fuel. This requires that the pressure be trapped prior to going to this step. Additionally a negative pressure reading may mean that there is either a faulty connection or a defective transducer. See section 11 for more on this. It might also indicate the system is improperly calibrated by the user. Re-do calibration on the transducers as required. PRESSURE TRANSDUCER 2 CALIBRATION This step is used to calibrate the test rig mounted transducer. Set the menu to indicate PT2. Repeat the step outlined above for PT1. PRESSURE TRANSDUCER 3 CALIBRATION This does not presently function. It is intended for possible future use. It can be skipped The Control Module can support six nozzles/hoses fueling individually or in combinations. It is necessary to calibrate the pulser and the pressure transducers 1, 2 and 3 as above on one nozzle or hose only. The calibration will automatically apply to these devices on all hose settings. However, the following nozzle pressure control setting must be performed on each hose individually. NOZZLE PRESSURE CONTROL SETTING (NORM) This step is used to set the control pressure for refueling. This procedure must be accomplished for each nozzle used. Hook up the nozzle to be calibrated to the recirculation or test adapter. If the nozzle has a Hose End Control Valve (HECV) it must be blocked open. On a Carter nozzle this can be accomplished by using the Block Out Device. The test rig transducer used in the previous calibration must remain connected to the Hand-Held Device. Push the right arrow to move to the nozzle (s) calibration mode. The display will scroll through a message that will ask one to press the down arrow button to begin calibration. ( TO CAL PRES PUSH DN BTN ). Activate the deadman and then press the down arrow. Establish a stable flow of fuel and then slowly throttle the valve downstream of the nozzle to create the desired back pressure or the pressure desired to refuel an aircraft as indicated on the control module. When the flow and pressure is stable and at the desired setting, release the deadman to set the pressure. The display will then indicate PSET and then show the set pressure. If the desired pressure has not been accomplished repeat this step to get the correct setting. If the setting is correct switch the Hand-Held to OPERATE to lock in the setting. 12

13 This procedure must be done for each nozzle. If one hose is used for an overwing nozzle application it is recommended that this nose/nozzle pressure setting be left at the default pressure of 35-psi. It is not possible to set a specific nozzle pressure using an overwing nozzle. This will provide adequate pressure for this operation and keep it low enough to make it easier for the operator to use the nozzle. When fueling with a combination of nozzles that are not necessarily set for the same control pressure the nozzle with the lowest set pressure will prevail. wants a pressure lower than normal to the industry. This can be accomplished by following the above procedure after first pressing and holding the button (12) on the bottom of the Control Module for at least 4- seconds. When this operation has been successful the (OVRRD) indicator light (7) on the module will be lit. Follow the above procedure for each nozzle to be used. If the OVERRIDEN pressure control is not set then the button on the bottom of the module will be inactive. To return to SETUP after completing this section of the procedure press the left arrow or to move on to the CONFIGURATION section of the menu press the right arrow twice. OVERRIDDEN (OVRRD) PRESSURE CONTROL SETTING This is a system function that allows the operator to switch fueling pressure settings from the NORMAL (NORM) settings. There may be some applications where an aircraft or customer 10.0 CONFIGURATION At present there are three active sections to the Configuration part of the setup, HOSE SELECTION, AUXILIARY OUTPUT and CGF. The FILTER selection is inactive and reserved for future use. If the vehicle is a refueler only two of these are necessary since the default setting for CGF (System Configuration) is for a refueler. Only if the vehicle is other than a refueler is it necessary to ever enter the CFG portion of the menu. AUXILIARY OUTPUT is used only if an auxiliary device, e.g. remote beacon or buzzer is installed and is operated by the system. Press the down arrow to enter the submenu of CONFIGURATION. The first setting display will be HSET. HOSE ASSIGNMENT TO PULSERS - If only one pulser (meter) is present this step can be skipped. The default setting is for one pulser. To assign a nozzle(s) to pulser one remove all nozzles to be so assigned from their stowage points and activate the deadman and hold it for a minimum of 15 seconds. Release the deadman. The nozzle indicator lights that are lit are now assigned to pulser one. Pulser 2 is not currently supported hence if the vehicle has two pulsers contact Carter at (949) for assistance. Therefore no nozzles can be assigned to pulser 2. FILTER This function is for future use only and is not active at this time. Press the right arrow to move on to the next function. AUXILIARY OUTPUT There are two selections in this section, D.FOL (deadman follower) and D.BEP (deadman beeper). D.FOL will switch the circuit to ground following the action of the deadman switch. D.BEP will provide a pulsing ground signal tied to the deadman timer function such that in the last 30- seconds of the timeout a remote beacon will flash in synch with the amber light on the module. 13

14 The maximum load on the appropriate terminals discussed in IN64235 Installation Instructions Manual is to be 28VDC at 2 amps. If a greater load is needed the appropriate relay will have to be installed. Set the display to A.OUT then press the down arrow to cycle through the two choices described above. Once the selection at D.FOL and D.BEP are set at the desired setting (YES or NO), press the right arrow to move on. CONFIGURATION (CFG) The display will indicate SYST CONF. Again if the vehicle is a refueler this step can be skipped. If it is other than a refueler then push the up or down buttons to arrive at the desired vehicle configuration. The USER and REF sections of the submenu are not currently active and are reserved for future use. Select REF (REF.T is inactive for now) for a refueler (factory default) or HYDR for a hydrant dispenser or cart using a hydrant coupler TROUBLE SHOOTING & ERROR CODESInitial Display Message 11.1 Re set When the power is turned on to the Control Module it will momentarily display the firmware version, e.g. C1.01. If this does not occur reset the unit as noted below. If this does not correct the problem contact Carter at (949) As noted above in section 4 to reset the unit turn off the power to the control module and turn it back on Reset to Factory Defaults It is possible to restore the factory defaults for all settings. Connect the Hand-Held Device, switch to MODIFY and push the up and down arrow buttons simultaneously. This will wipe out all previous customer settings but it is not to be used to service an aircraft until the unit has been properly recalibrated Erro r Codes Digital II includes self-diagnosing functions and when a problem is encountered an error code will be displayed as follows: E1.1 Processor has encountered an Invalid Instruction. (OPERATIONS STOP..!) E1.2 Interrupt from an unassigned or reserved area. (OPERATIONS STOP..!) E1.3 An unknown Interrupt has occurred. (OPERATIONS STOP..!) E1.4 A Clock Failure has occurred.. (OPERATIONS STOP..!) E1.5 A System Monitor Interrupt has occurred. (OPERATIONS STOP..!) 14 E2.1 Zero or Negative pressure calculated. (OPERATIONS CONTINUE..!) E2.2 Cv is calculated as Less than one. (OPERATIONS CONTINUE..!) E2.3 Press ure is too large to be displayed. (OPERATIONS CONTINUE..!) E2.4 Press ure is Negative. (OPERATIONS CONTINUE..!) E3.1 Control Module has lost contact with VEHICLE Pressure Transducer. E3.2 Control Module has lost contact with NOZZLE Pressure Transducer. E3.3 Control Module has lost contact with FILTER Pressure Transducer. E4.1 Invalid Display Address firmware error. E9.1 Power Supply Voltage to Control Module has dropped BELOW 10 Volts. If Error Codes 1.1 through 1.5 are displayed the problem may be resolved by completing a Power-On Reset. This will return all of the Setup, Calibration and Configuration settings to the factory default setting. Therefore, before the unit is returned to service, it MUST be subjected to the Setup, Calibration and Configuration procedures. If this does not resolve the problem, contact. Carter at (949) It is possible that during normal operation, the Error Codes 2.1 through 2.4 will appear on the display, for a very short period of

15 time. It may flash on the display or may stay on as long as two seconds, before the display returns to normal operation. If this occurs, it will not affect the operation of the unit. If any of these error codes appear for 10 seconds or longer during calibration or immediately after calibration this would indicate that the calibration is invalid. It is very important that each step of the Setup, Calibration and Configuration procedure be completed. If the nozzle is equipped with an HECV (Hose-End-Control-Valve) it is essential that the block-out device is secure and fully engaged in the HECV. The blockout device can easily back out and allow the valve to control. If this occurs the information provided during pressure calibration would be invalid, so you would be required to repeat the Setup, Calibration and Configuration procedure. If Error Codes between 3.1 and 3.3 are encountered, refer to section 10.6 for instructions to check the transducer and cable. If Error Code 9.1is encountered, conclude that the supply voltage to the control module has dropped below 10 Volts. Check to ensure that Terminal # 1, #2 and #3 are tight and the wires are secure. With a voltmeter, check the Input Voltage at Terminal # 1. If this is below 10 Volts, repair the vehicle power supply as required. If the voltage reading is above 10 volts, contact Carter at (949) N egative Pressure Reading If the pressure display indicates a negative pressure reading, this would indicate that the transducer has a faulty connection or is defective or the system is improperly calibrated. Check Terminals #11, 12 and 13 to ensure that they are tight and that the wire is secure. Inspect the cable to ensure that it has not been cut or broken. Remove the connection to the transducer and ensure that the contacts are clean and dry. To perform a continuity check on the cable the wires must be disconnected from the transducer and the control module terminal. To assure that the wires are reconnected correctly, mark the wires before disconnecting them from the terminal connector. Visually inspect the transducer. If it is bent or dented, it is likely to be defective. If the transducer appears to be in good condition, you can test the output to ensure that it is functioning properly. To test operation of the Vehicle Mounted Transducer, activate the pumping system and establish a flow of fuel. Contact the red or positive lead from a voltage meter to Terminal #11 and the black (negative) lead to Terminal #13 and measure the voltage. The voltage should be between 1 and 6 Volts DC. If it is higher or lower than that this, the transducer is certainly defective. Adjust any manually operated valve mounted down stream of the vehicle-mounted transducer in order to cause the pressure to fluctuate. Observe that the voltage also raises and lowers with the fuel pressure. If this voltage remains stable, check the operation of the test rig transducer. Exchange this device with the vehicle mounted transducer. (There are no terminals available to check the output of the Test Rig Transducer). If the pressure transducers are checked to be working properly, re-calibration of the system might be required Summary of Warnings and Cautions SINGLE NOZZLE FLOW LIMIT Only one nozzle at a time can be active. If more than one nozzle is activated the display will be blank. NEGATIVE PRESSURE INDICATION This indicates that either the pressure transducer is faulty or is not connected to the system. It might also indicate the system is improperly calibrated by the user. Re-do calibration on the transducers as required. DO NOT ATTEMPT TO ADJUST FROM A ZERO PRESSURE READING NORMAL/OVERRIDDEN CONTROL SETUP The button on the bottom of the unit is meant to be used to choose an alternate or overridden pressure control. It must be setup properly before it is usable. 15

16 HOSE/NOZZLE CALIBRATION Nozzles can be used in any combination but only one can be calibrated at a time or a blank screen will be displayed. DEADMAN TIMEOUT As with the pressure setting the deadman timeout will be the lowest set when using more than one nozzle at a time.fluid Power Group USING MULTIPLE HOSES The nozzl e pressure will be the lowest of that set by the user for multiple nozzle use. Aerospace Group Conveyance Systems Division 9650 Jeronimo Rd Irvine, CA Ph (949) Fax (949)

Digital II Pressure Control System. Model UM64135 User's Manual October 7, 2002 Applicable additional manuals: NONE.

Digital II Pressure Control System. Model UM64135 User's Manual October 7, 2002 Applicable additional manuals: NONE. Aerospace Group Conveyance Systems Divison Carter Brand Ground Fueling Equipment UM64135 User's Manual October 7, 2002 Applicable additional manuals: NONE User Manual Digital II Pressure Control System

More information

Digital III Fueling Vehicle Control System

Digital III Fueling Vehicle Control System SM64335-2 April 2005 Aerospace Group Conveyance Systems Division Carter Brand Ground Fueling Equipment Applicable additional manuals: SM64335-1 Setup & Calibration User s Manual Digital III Fueling Vehicle

More information

Digital II Pressure Control Module. Model IN64235 August Installation Instructions. Applicable addition manuals:

Digital II Pressure Control Module. Model IN64235 August Installation Instructions. Applicable addition manuals: Aerospace Group Conveyance Systems Division Carter Brand Ground Fueling Equipment IN64235 August 2009 Applicable addition manuals: IN64101 IN64108 IN64102 IN64802 SU64235 Installation Instructions Digital

More information

Inline Pressure Control Or Shutoff Valves (Non-digital) And Bypass Pressure Control Or Shutoff Valves (Non-digital)

Inline Pressure Control Or Shutoff Valves (Non-digital) And Bypass Pressure Control Or Shutoff Valves (Non-digital) IN64124 August 15, 1997 Aerospace Group Conveyance Systems Divison Carter Brand Ground Fueling Equipment Applicable additional manuals: Installation Instructions Inline Pressure Control Or Shutoff Valves

More information

Transducer/Cable Assembly. Model IN64108 August 1997 Applicable additional manuals: IN64035 INSTALLATION INSTRUCTION. Installation Instruction

Transducer/Cable Assembly. Model IN64108 August 1997 Applicable additional manuals: IN64035 INSTALLATION INSTRUCTION. Installation Instruction Aerospace Group Conveyance Systems Division Carter Brand Ground Fueling Equipment IN64108 August 1997 Applicable additional manuals: IN64035 INSTALLATION INSTRUCTION Installation Instruction Transducer/Cable

More information

MAGPOWR Spyder-Plus-S1 Tension Control

MAGPOWR Spyder-Plus-S1 Tension Control MAGPOWR TENSION CONTROL MAGPOWR Spyder-Plus-S1 Tension Control Instruction Manual Figure 1 EN MI 850A351 1 A COPYRIGHT All of the information herein is the exclusive proprietary property of Maxcess International,

More information

Solenoid Valve Manifold for use with Digital Pressure Control Coupler

Solenoid Valve Manifold for use with Digital Pressure Control Coupler Aerospace Group Conveyance Systems Division Carter Brand Ground Fueling Equipment IN64102 August 1997 Applicable additional manuals: IN64035 Installation Instruction IN64702 Installation Instruction Installation

More information

CONTROLLER DIAGNOSTIC GUIDE

CONTROLLER DIAGNOSTIC GUIDE Proprietary tice: This document contains proprietary information which not to be reproduced, transferred, to other documents, disclosed to others, used for manufacturing or any other purpose without the

More information

PF3100 TROUBLESHOOTING SOLUTIONS TO COMMON PROBLEMS. v1.1 Revised Nov 29, 2016

PF3100 TROUBLESHOOTING SOLUTIONS TO COMMON PROBLEMS. v1.1 Revised Nov 29, 2016 PF3100 TROUBLESHOOTING SOLUTIONS TO COMMON PROBLEMS v1.1 Revised Table of Contents 1 Common Alarms and Warnings... 1 2 Common Issues... 6 2.1 Communication problems... 6 2.1.1 Controller communication

More information

PCS GEAR SELECT MODULE USER GUIDE v4.0

PCS GEAR SELECT MODULE USER GUIDE v4.0 PCS GEAR SELECT MODULE USER GUIDE v4.0 Ph: 1.804.227.3023 www.powertraincontrolsolutions.com Powertrain Control Solutions 1 Introduction 1.1 Included Components 1 - GSM Cable Motor Enclosur 1 - GSM Driver

More information

PRESSURE GOVERNOR, ENGINE MONITORING, AND MASTER PRESSURE DISPLAY MODEL: TCA100

PRESSURE GOVERNOR, ENGINE MONITORING, AND MASTER PRESSURE DISPLAY MODEL: TCA100 Document Number: XE-TCA1PM-R0A TCA100 Rev0511 PRESSURE GOVERNOR, ENGINE MONITORING, AND MASTER PRESSURE DISPLAY MODEL: TCA100 FIRE RESEARCH CORPORATION www.fireresearch.com 26 Southern Blvd., Nesconset,

More information

RD712 & RD712XL Remote Displays. Model 615 / 615XL Indicator User s Manual

RD712 & RD712XL Remote Displays. Model 615 / 615XL Indicator User s Manual RD712 & RD712XL Remote Displays Model 615 / 615XL Indicator User s Manual EUROPEAN COUNTRIES WARNING This is a Class A product. In a domestic environment this product may cause radio interference in which

More information

Factory Packaged Controls. OE (AAON Part No. V12090) MODGAS-X Controller Field Technical Guide

Factory Packaged Controls. OE (AAON Part No. V12090) MODGAS-X Controller Field Technical Guide Factory Packaged Controls OE377-26-00058 (AAON Part No. V12090) MODGAS-X Controller Table of Contents GENERAL INFORMATION... 3 Overview...3 Features...3 INSTALLATION & WIRING... 4 Supply Air Temperature

More information

Digital Manifold with Digital Hydrant Control

Digital Manifold with Digital Hydrant Control IN64302 December 2008 Aerospace Group Conveyance Systems Division Carter Brand Ground Fueling Equipment Applicable additional manuals: IN64235 IN64108 IN64702 SU64235 Installation Instructions Digital

More information

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets Art. nr. 40200261 OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets WHISPERPOWER BV Kelvinlaan 82 9207 JB Drachten Netherlands Tel.: +31-512-571550 Fax.: +31-512-571599

More information

Series 20 Installation Instructions

Series 20 Installation Instructions Series 20 Installation Instructions Installation Instructions and field service checklist Read these instructions carefully. Failure to follow them could result in a fire or explosion causing property

More information

Thunder Power Tarp Kit Operation. Dual Arm Curb Side Stowing Single Arm Curb Side Stowing Flex Arm Curb Side Stowing.

Thunder Power Tarp Kit Operation. Dual Arm Curb Side Stowing Single Arm Curb Side Stowing Flex Arm Curb Side Stowing. Thunder Power Tarp Kit Operation Dual Arm Curb Side Stowing Single Arm Curb Side Stowing Flex Arm Curb Side Stowing 011-52475 Rev - 2 P a g e USE THE PROCEDURES BELOW TO OPERATE THE TARP SYSTEM Powering

More information

Digital Diesel Control Remote control panel for GENVERTER GV4 and GV7i

Digital Diesel Control Remote control panel for GENVERTER GV4 and GV7i OPERATING MANUAL Digital Diesel Control Remote control panel for GENVERTER GV4 and GV7i Art. nr. 40200801 WHISPER POWER BV ENGLISH: PAGE 1 Kelvinlaan 82 9207 JB Drachten NEDERLANDS: PAGINA 41 Netherlands

More information

Models & Inch & 4 Inch Digital Inline Pressure Control Valves SM64504

Models & Inch & 4 Inch Digital Inline Pressure Control Valves SM64504 SM64504 September 2008 Aerospace Group Conveyance Systems Division Carter Brand Ground Fueling Equipment Applicable addition manuals: None Maintenance & Repair Manual 3 Inch & 4 Inch Digital Inline Pressure

More information

FL-100-R (109) Operations and Installation Manual

FL-100-R (109) Operations and Installation Manual Page 1 of 23 All specification subject to change 2002-2005 FL-100-R (109) Operations and Installation Manual This manual is certified for use with instrument serial number ASL000000 Use of this manual

More information

PRESSURE GOVERNOR, ENGINE MONITORING, AND MASTER PRESSURE DISPLAY MODEL DDA100

PRESSURE GOVERNOR, ENGINE MONITORING, AND MASTER PRESSURE DISPLAY MODEL DDA100 PRESSURE GOVERNOR, ENGINE MONITORING, AND MASTER PRESSURE DISPLAY MODEL DDA100 1 CONTENTS Table of Contents CONTENTS... 2 INTRODUCTION... 4 Overview... 4 Features... 4 GENERAL DESCRIPTION... 5 2 List of

More information

Application Engineering Europe

Application Engineering Europe Date of last update: Feb-12 Ref: D7.8.4/0112-0212/E Application Engineering Europe CORESENSE DIAGNOSTICS FOR STREAM REFRIGERATION COMPRESSORS 1/17 1 Introduction CoreSense is an ingredient brand name for

More information

Subject Underhood G System Error Codes and Symptoms System or Parts affected

Subject Underhood G System Error Codes and Symptoms System or Parts affected System or Parts affected Index Underhood70G (V90Gxxx) System or Parts affected... 1 Overview... 1 Identifying your System... 1 Retrieving Logged Error Messages... 1 Error Messages... 3 Error Message Table...

More information

GPS AutoSteer System Installation Manual

GPS AutoSteer System Installation Manual GPS AutoSteer System Installation Manual Supported Vehicles Case IH Combines 7010 7120 8010 8120 AFX 8010 9120 PN: 602-0283-01-A LEGAL DISCLAIMER Note: Read and follow ALL instructions in this manual carefully

More information

Freeman 380/385 Hydro PTO Operator Controls and Baler Connection Instructions

Freeman 380/385 Hydro PTO Operator Controls and Baler Connection Instructions Freeman 380/385 Hydro PTO Operator Controls and Baler Connection Instructions The following pages detail how to connect and use the controls on your Hydro PTO Baler. Please consult Operators manual PB00000102

More information

SERVICE MANUAL. Kysor Instrumentation Troubleshooting Guide

SERVICE MANUAL. Kysor Instrumentation Troubleshooting Guide Kysor Instrumentation Troubleshooting Guide Troubleshooting Emergency One Commercial System The Medallion II instrumentation system is a Microprocessor based system utilizing both Sensor and Data bus information

More information

Model INTERNAL/BOTTOM LOADING VALVES SM Maintenance & Repair Manual. July Applicable addition manuals: None

Model INTERNAL/BOTTOM LOADING VALVES SM Maintenance & Repair Manual. July Applicable addition manuals: None SM64128 July 2010 Eaton Aerospace Group Conveyance Systems Division Carter Brand Ground Fueling Equipment Applicable addition manuals: None Maintenance & Repair Manual 6 INTERNAL/BOTTOM LOADING VALVES

More information

3 Phase Smart Controller

3 Phase Smart Controller 3 Phase Smart Controller Installation and Owner s Manual STP-SCIII 208-230 VAC, 60Hz, 120 Volt Coil Franklin Fueling 3760 Marsh Rd. Madison WI 53718 USA Tel: +1 608 838 8786 800 225 9787 Fax: +1 608 838

More information

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor World Leader in Modular Torque Limiters Installation and Maintenance Instructions PTM-4 Load Monitor 1304 Twin Oaks Street Wichita Falls, Texas 76302 (940) 723-7800 Fax: (940) 723-7888 E-mail: sales@brunelcorp.com

More information

The RCS-6V kit. Page of Contents. 1. This Book 1.1. Warning & safety What can I do with the RCS-kit? Tips 3

The RCS-6V kit. Page of Contents. 1. This Book 1.1. Warning & safety What can I do with the RCS-kit? Tips 3 The RCS-6V kit Page of Contents Page 1. This Book 1.1. Warning & safety 3 1.2. What can I do with the RCS-kit? 3 1.3. Tips 3 2. The principle of the system 2.1. How the load measurement system works 5

More information

Spray Height Controller

Spray Height Controller Spray Height Controller UC5 SERVICE MANUAL 2012 Printed in Canada Copyright 2012 by NORAC Systems International Inc. Reorder P/N: UC5 SERVICE MANUAL 2012 Rev B NOTICE: NORAC Systems International Inc.

More information

Owner and Operating Manual for

Owner and Operating Manual for Owner and Operating Manual for 120VAC Manual Control 12VDC Solar Battery Manual Control 120VAC Remote Control 12VDC Solar Battery Remote Control GEN2 Remote Versions Only Boat Lifts Please read this manual

More information

Quick Setup Guide for IntelliAg Model 3PYP 12 Row Single Row Air Pro

Quick Setup Guide for IntelliAg Model 3PYP 12 Row Single Row Air Pro STEP 1: Pre-Programming Preparation: Power on vehicle via ignition switch to activate Virtual Terminal (VT). Main menu will display pre-programmed default settings. If errors are detected (e.g., failed

More information

Altec LMAP. (Load Moment and Area Protection) Telescopic Boom Cranes. Calibration

Altec LMAP. (Load Moment and Area Protection) Telescopic Boom Cranes. Calibration Altec LMAP (Load Moment and Area Protection) Telescopic Boom Cranes Calibration Contents System Components...1 Anti-Two Block...1 Area Alarm...1 Boom Angle Sensor...1 Display...1 Extension Sensor...2 Function

More information

LEAK TEST PROCEDURE MRTALPCH611LDC REMOTE READY LIFTERS W/ 3 BUTTON CONTROL APPLICABLE TO LIFTERS WITH SERIAL NUMBERS GREATER THAN #

LEAK TEST PROCEDURE MRTALPCH611LDC REMOTE READY LIFTERS W/ 3 BUTTON CONTROL APPLICABLE TO LIFTERS WITH SERIAL NUMBERS GREATER THAN # LEAK TEST PROCEDURE MRTALPCH611LDC REMOTE READY LIFTERS W/ 3 BUTTON CONTROL APPLICABLE TO LIFTERS WITH SERIAL NUMBERS GREATER THAN # 20100742 TESTING AND MAINTENANCE MUST BE DONE BY A QUALIFIED PERSON

More information

WARRANTY AND DISCLAIMER

WARRANTY AND DISCLAIMER MEGA 100/200 WARRANTY AND DISCLAIMER DIGITAL DELAY INC. WARRANTS THE PRODUCTS IT MANUFACTURES AGAINST DEFECTS IN MATERIALS AND WORKMANSHIP FOR A PERIOD LIMITED TO 1 YEAR FROM THE DATE OF SHIPMENT, PROVIDED

More information

3 Inch & 4 Inch Fuel Operated Bypass Pressure Control Valves. Models & 64513

3 Inch & 4 Inch Fuel Operated Bypass Pressure Control Valves. Models & 64513 SM64503 September 2008 Aerospace Group Conveyance Systems Division Carter Brand Ground Fueling Equipment Applicable addition manuals: None Maintenance & Repair Manual 3 Inch & 4 Inch Fuel Operated Bypass

More information

CORESENSE DIAGNOSTICS FOR STREAM REFRIGERATION COMPRESSORS

CORESENSE DIAGNOSTICS FOR STREAM REFRIGERATION COMPRESSORS Date of last update: Apr-15 Ref: D7.8.4/0112-0415/E Application Engineering Europe CORESENSE DIAGNOSTICS FOR STREAM REFRIGERATION COMPRESSORS CoreSense Diagnostics for Stream Refrigeration Compressors...

More information

INSTRUCTIONS FAST TM BUMP STAGER TM (#30322) System Overview

INSTRUCTIONS FAST TM BUMP STAGER TM (#30322) System Overview 1 INSTRUCTIONS FAST TM BUMP STAGER TM (#30322) Thank you for choosing products; we are proud to be your manufacturer of choice. Please read this instruction sheet carefully before beginning installation,

More information

1014-SCR WARRANTY AND DISCLAIMER Fillmore Street Davenport, Ia

1014-SCR WARRANTY AND DISCLAIMER Fillmore Street Davenport, Ia 2036 Fillmore Street Davenport, Ia. 52804 563-324-1046 www.racedigitaldelay.com 1014-SCR WARRANTY AND DISCLAIMER DIGITAL DELAY INC. WARRANTS THE PRODUCTS IT MANUFACTURES AGAINST DEFECTS IN MATERIALS AND

More information

INSTALLATION: HOW IT WORKS: SensiStat Energy Saver Refrigeration Controller. both the holding plate temperature and refrigeration box temperature.

INSTALLATION: HOW IT WORKS: SensiStat Energy Saver Refrigeration Controller. both the holding plate temperature and refrigeration box temperature. both the holding plate temperature and refrigeration box temperature. SensiStat Energy Saver Refrigeration Controller HOW IT WORKS:...1 INSTALLATION:...1 OPERATION:...2 CUSTOMIZATION:...4 TROUBLE SHOOTING:...6

More information

Rally computer 3 Rally computer 3.GPS *

Rally computer 3 Rally computer 3.GPS * Rally computer 3 Rally computer 3.GPS * User manual. Installation and configuration instructions. (with links to video instructions online at : www.rallycomputer.com ) * Content marked applies only to

More information

Product Guide: Series III Pump Control Board Set (RoHS)

Product Guide: Series III Pump Control Board Set (RoHS) revised 04/08/10 Description: The Series III Pump Control Board Set provides motor drive and pump control for a wide assortment of pumps from Scientific Systems, Inc. The assembly consists of two circuit

More information

Instruction of connection and programming of the VECTOR controller

Instruction of connection and programming of the VECTOR controller Instruction of connection and programming of the VECTOR controller 1. Connection of wiring 1.1.VECTOR Connection diagram Fig. 1 VECTOR Diagram of connection to the vehicle wiring. 1.2.Connection of wiring

More information

DIGITAL FLOWMETER AND PRESSURE INDICATOR MODEL FPA400

DIGITAL FLOWMETER AND PRESSURE INDICATOR MODEL FPA400 Document Number: XE-FPA4PM-R0A FPA400 Rev160601 DIGITAL FLOWMETER AND PRESSURE INDICATOR MODEL FPA400 OPTIONAL BACKLIGHTING FIRE RESEARCH CORPORATION www.fireresearch.com 26 Southern Blvd., Nesconset,

More information

TECHNICAL PAPER 1002 FT. WORTH, TEXAS REPORT X ORDER

TECHNICAL PAPER 1002 FT. WORTH, TEXAS REPORT X ORDER I. REFERENCE: 1 30 [1] Snow Engineering Co. Drawing 80504 Sheet 21, Hydraulic Schematic [2] Snow Engineering Co. Drawing 60445, Sheet 21 Control Logic Flow Chart [3] Snow Engineering Co. Drawing 80577,

More information

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00 Inlet Controller TC5-ITA USER'S MANUAL M 890-00047 rev. 02 K 895-00458 rev. 00 TABLE OF CONTENTS PRECAUTIONS... 3 FEATURES... 4 LOCATION OF THE CONTROLS... 5 Status Leds...5 Internal Switches...6 INSTALLATION

More information

INSTALLATION & OPERATION MANUAL

INSTALLATION & OPERATION MANUAL INSTALLATION & OPERATION MANUAL MODEL T575N TEMPERATURE COMPENSATED TOTALIZER/PRINTER DOC#: MN-T575N SPONSLER, INC. Liquid and Gas Flow Measuring Devices and Controls LBS ON OFF TRUCK TOTALIZER MODEL T575N

More information

ITCEMS950 Idle Timer Controller - Engine Monitor Shutdown Isuzu NPR 6.0L Gasoline Engine

ITCEMS950 Idle Timer Controller - Engine Monitor Shutdown Isuzu NPR 6.0L Gasoline Engine Introduction An ISO 9001:2008 Registered Company ITCEMS950 Idle Timer Controller - Engine Monitor Shutdown 2014-2016 Isuzu NPR 6.0L Gasoline Engine Contact InterMotive for additional vehicle applications

More information

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM DSE 520 ISSUE 4 4/4/02 MR 1 TABLE OF CONTENTS Section Page INTRODUCTION... 4 CLARIFICATION OF NOTATION USED WITHIN THIS PUBLICATION.... 4 1. OPERATION...

More information

SM64155 Maintenance & Repair Manual

SM64155 Maintenance & Repair Manual SM64155 September 2011 Applicable addition manuals: Aerospace Group Conveyance Systems Division Carter Brand SM61429 Nozzle SM64349 Nozzle SM64201 Nozzle Maintenance & Repair Manual Continuity Dry Break

More information

Installation and Operations Manual

Installation and Operations Manual Excalibur Water Systems 3.0 High Capacity Superflow Series QUADPLEX Water Softener Installation and Operations Manual 142 Commerce Park Drive, Units M-O, Barrie ON L4N 8W8 www.excaliburwater.com Water

More information

The function of this Dynamic Active Probe has divided into three preferences on the screen main Menus:

The function of this Dynamic Active Probe has divided into three preferences on the screen main Menus: 1.0 Introduction: This probe is designed to provide an additional help to automotive technicians in trouble shooting of electrical circuits problems in the car. Apart from using the normal multi tester,

More information

Thunder Power Tarp Kit Operation

Thunder Power Tarp Kit Operation Thunder Power Tarp Kit Operation Dual Arm Curb Side Stowing Single Arm Curb Side Stowing 011-52476 Rev. H P a g e 2 In this booklet you will find: OPERATING INSTRUCTIONS... 3 Powering up or down the system...

More information

Idle Timer Controller - ITC Freightliner MT45 Contact InterMotive for additional vehicle applications

Idle Timer Controller - ITC Freightliner MT45 Contact InterMotive for additional vehicle applications An ISO 9001:2008 Registered Company System Operation Idle Timer Controller - ITC805 2013-2018 Freightliner MT45 Contact InterMotive for additional vehicle applications The ITC805 system shuts down idling

More information

SOLAR LIGHTING CONTROLLER SUNLIGHT MODELS INCLUDED IN THIS MANUAL SL-10 SL-10-24V SL-20 SL-20-24V

SOLAR LIGHTING CONTROLLER SUNLIGHT MODELS INCLUDED IN THIS MANUAL SL-10 SL-10-24V SL-20 SL-20-24V SOLAR LIGHTING CONTROLLER OPERATOR S MANUAL SUNLIGHT MODELS INCLUDED IN THIS MANUAL SL-10 SL-10-24V SL-20 SL-20-24V 10A / 12V 10A / 24V 20A / 12V 20A / 24V 1098 Washington Crossing Road Washington Crossing,

More information

PowerLevel s e r i e s

PowerLevel s e r i e s Owner s Manual Hydraulic Leveling CONTENTS Introduction Operation Control Panel Automatic Leveling Manual Leveling Retracting Jacks Remote Operation Care & Maintenance Troubleshooting Error Codes 1 2 2

More information

Section 55 Chapter 6

Section 55 Chapter 6 Section 55 Chapter 6 REMOTE HYDRAULICS CONTROLLER Calibration and Fault Codes 6-12880NH TABLE OF CONTENTS REMOTE HYDRAULICS CONTROLLER CALIBRATION... 55-5 Requirements For Calibration... 55-5 Aux Set Main

More information

Operations Manual. Automated Fuel Maintenance System FUEL TECHNOLOGIES INTERNATIONAL

Operations Manual. Automated Fuel Maintenance System FUEL TECHNOLOGIES INTERNATIONAL Operations Manual Automated Fuel Maintenance System FTI-10A & 20A FUEL TECHNOLOGIES INTERNATIONAL Replacement Manuals Available on Website: www.fueltechnologiesinternational.com 07/15/2015 Rev E Fuel Technologies

More information

Trouble Shooting Manual Progressive Systems

Trouble Shooting Manual Progressive Systems 1 INTRODUCTION The information contained in this manual provides insight in how a progressive grease distribution system works and how to trouble shoot a progressive system. 2 OPERATING PRINCIPLE Any pump

More information

ESCONDIDO FIRE DEPT TRAINING MANUAL Section DRIVER OPERATOR Page 1 of 13 Pumps and Accessory Equipment Revised

ESCONDIDO FIRE DEPT TRAINING MANUAL Section DRIVER OPERATOR Page 1 of 13 Pumps and Accessory Equipment Revised DRIVER OPERATOR Page 1 of 13 PUMPS AND ACCESSORY EQUIPMENT Pumps are designed for many different purposes. In order to understand the proper application and operation of a pump in a given situation, firefighters

More information

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320 Inlet Controller SB 2000 USER'S MANUAL AUTO OPEN MANUAL PUSH TO SEARCH NEXT STAG E CLOSE Aerotech, Inc. FORM: QM 1320 4215 Legion Dr. Mason, MI 48854-1036 USA Rev. 3, Sept. 1997 Ph. (517) 676-7070 Fax

More information

Do isolate the power supply from other high power systems such as Stereos and Alarms

Do isolate the power supply from other high power systems such as Stereos and Alarms Thank you for purchasing a Smart Ride Air Management System, AIRBAGIT.COM s premier flagship product. This system will meet all of your custom and utility needs and will provide you years of trouble free

More information

AgXcel GX5 Install Guide for Integration into Trimble. where precision meets the soil... PO Box 1611 Kearney, NE

AgXcel GX5 Install Guide for Integration into Trimble. where precision meets the soil... PO Box 1611 Kearney, NE where precision meets the soil... AgXcel GX5 Install Guide for Integration into Trimble PO Box 1611 Kearney, NE 68848 877.218.1981 www.agxcel.com where precision meets the soil... AgXcel Integration into

More information

TECHNICAL NOTE #4 Revised May 24, BOGART ENGINEERING Two Bar Road, Boulder Creek, CA (831)

TECHNICAL NOTE #4 Revised May 24, BOGART ENGINEERING Two Bar Road, Boulder Creek, CA (831) TECHNICAL NOTE #4 Revised May 24, 2004 BOGART ENGINEERING 19020 Two Bar Road, Boulder Creek, CA 95006 (831) 338-0616 TROUBLESHOOTING the TriMetric battery monitor Revised for the TM-2020 TriMetric What

More information

SM64052 Maintenance & Repair Manual Commercial 2" Unisex Coupling - Valved Model 64052

SM64052 Maintenance & Repair Manual Commercial 2 Unisex Coupling - Valved Model 64052 Aerospace Group Conveyance Systems Division Carter Brand Ground Fueling Equipment SM64052 July 2004 Applicable additional manuals: SM64051 Commercial 2" Unisex Coupling, Non-Valved Maintenance & Repair

More information

SensiStat Energy Saver Refrigeration Controller Revision 1.14

SensiStat Energy Saver Refrigeration Controller Revision 1.14 SensiStat Energy Saver Refrigeration Controller Revision 1.14 HOW IT WORKS:... 1 INSTALLATION:... 2 OPERATION:... 3 CUSTOMIZATION:... 5 TROUBLE SHOOTING:... 9 FACEPLATE TEMPLATE... 11 The SCAD SensiStat

More information

Deep Sea Electronics Plc

Deep Sea Electronics Plc Deep Sea Electronics Plc 5120 AUTOMATIC MAINS FAILURE MODULE OPERATING MANUAL Author: Anthony Manton Deep Sea Electronics Plc Highfield House Hunmanby North Yorkshire YO14 0PH England Tel: +44 (0) 1723

More information

Rallye VR Light. MADE IN USA

Rallye VR Light. MADE IN USA Rallye VR Light MADE IN USA www.icoracing.com Contents Introduction Overview of operation New Functions Button Symbols Page 11 2 Setup functions Functions in a race Edit Set wheel circumference Show clock/hide

More information

DIGITAL PRESSURE AND FLOW INDICATOR MODEL FPA500

DIGITAL PRESSURE AND FLOW INDICATOR MODEL FPA500 Document Number: XE-FPA5PM-R0A FPA500 Rev150728 DIGITAL PRESSURE AND FLOW INDICATOR MODEL FPA500 FIRE RESEARCH CORPORATION www.fireresearch.com 26 Southern Blvd., Nesconset, NY 11767 TEL 631.724.8888 FAX

More information

2007 Mercury Marine SmartCraft Gauges

2007 Mercury Marine SmartCraft Gauges i 27 Mercury Marine SmartCraft Gauges 9-89828315 97 ii TABLE OF CONTENTS System Tachometer/Speedometer Basic Operation and Features...1 Automatic Engine Detection Feature...1 Master Reset...2 Alarm Warnings...3

More information

Maximiser Progressive Controller

Maximiser Progressive Controller Maximiser Progressive Controller Street & Race Model Owner's Manual 44 (0) 01302 834343 www.noswizard.com Introduction Congratulations on purchasing the Maximiser for the ultimate in progressive nitrous

More information

Price Computing Scale D Series Operation Manual

Price Computing Scale D Series Operation Manual This Document is Hosted by: www.oldwillknottscales.com Price Computing Scale D Series Operation Manual Cardinal Scale Manufacturing Co. 8529-M400-O1 Rev. A PO BOX 151 WEBB CITY, MO 64870 04/13 PH (417)

More information

Installation and User Manual. with RAIN SENSOR.

Installation and User Manual. with RAIN SENSOR. with RAIN SENSOR www.solarsmartopener.com Revision..0 TABLE OF CONTENTS Features In The Box Further Items Required Basic Operation Solar Panel and Operator Installation Operator Installation Solar Panel

More information

Glow Plug for E Series Only

Glow Plug for E Series Only Charging the Battery - Do not charge the battery, with a charger using negative discharge pulses, when connected to the ECU. This will destroy the electronics of the ECU. The only method is to disconnect

More information

Interior Digital Load Scale 202-DDG-02. Installation and Operation Manual Please read carefully before installation

Interior Digital Load Scale 202-DDG-02. Installation and Operation Manual Please read carefully before installation Interior Digital Load Scale 202-DDG-02 Installation and Operation Manual Please read carefully before installation Contents Specifications:... 2 1.0 Installation and Set-up Overview... 3 2.0 Gauge Installation

More information

Product Instruction. Door Control Board: Board 1Ø4 for PM/SSC (R3)

Product Instruction. Door Control Board: Board 1Ø4 for PM/SSC (R3) Door Control Board: Board 1Ø4 for PM/SSC 61111-149 (R3) 2000-08-31 2000, 1992 KONE Inc. Unpublished work. All rights reserved. No portion of this volume may be used or reproduced in any manner without

More information

Installation & Operation Manual. IMPORTANT: This manual contains important information. READ AND KEEP FOR REFERENCE.

Installation & Operation Manual. IMPORTANT: This manual contains important information. READ AND KEEP FOR REFERENCE. Elecronic Preset Meter 2 Industrial Handheld Series Model EPM2-IND Standard Series IMPORTANT: This manual contains important information. READ AND KEEP FOR REFERENCE. IOM-139-02-EN (1-12) 53400-139 Rev.

More information

LCI Level-Up Motorhome Leveling (2013-Present) OWNER'S MANUAL. Rev: Page 1 LCILevel-Up MotorhomeLeveling (2013-Present)OwnersManual

LCI Level-Up Motorhome Leveling (2013-Present) OWNER'S MANUAL. Rev: Page 1 LCILevel-Up MotorhomeLeveling (2013-Present)OwnersManual LCI Level-Up Motorhome Leveling (2013-Present) OWNER'S MANUAL Rev: 05.23.2016 Page 1 LCILevel-Up MotorhomeLeveling (2013-Present)OwnersManual TABLE OF CONTENTS System Information 3 Prior To Operation 3

More information

Quick Setup Guide for IntelliAg Model YP40 20 Air Pro

Quick Setup Guide for IntelliAg Model YP40 20 Air Pro STEP 1: Pre-Programming Preparation: The Quick Guide assumes the Virtual Terminal, Master Switch, Working Set Master, Working Set Member, and all sensors have been connected and properly installed. Reference

More information

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide 11451 Belcher Road South, Largo, FL 33773 USA Tel +1 (727) 447-6140 Fax +1 (727) 442-5699 1054-7 / 34405 www.onicon.com sales@onicon.com

More information

6.0 SPECIFICATIONS CONTENTS. Calibration. According to factory procedureeeeeeeeeeeeeee Accuracy*

6.0 SPECIFICATIONS CONTENTS. Calibration. According to factory procedureeeeeeeeeeeeeee Accuracy* 6.0 SPECIFICATIONS Calibration According to factory procedureeeeeeeeeeeeeee Accuracy* ± 1% full scale (FS) or ± 1 graduation on scale Scale diameter 41 mm Temperature range 45 to 115 F (10-45 C) Air humidity

More information

Use the instructions in this document to troubleshoot any issue with Digital EPIC-2.

Use the instructions in this document to troubleshoot any issue with Digital EPIC-2. Use the instructions in this document to troubleshoot any issue with Digital EPIC-2. Table of contents 1. Introduction... 2 2. Calibration errors... 2 2.1 Valve close error... 3 2.2 Valve open error...

More information

Ford Gasoline Speedo-Pro Programmer. Reprogram. Power

Ford Gasoline Speedo-Pro Programmer. Reprogram. Power Ford Gasoline Speedo-Pro Programmer 4 Reprogram Power INSTALLATION INSTRUCTIONS OVERVIEW Your vehicle has an onboard computer that controls the engine and transmission. The JET programmer reprograms your

More information

1014-CTC WARRANTY AND DISCLAIMER

1014-CTC WARRANTY AND DISCLAIMER 2036 Fillmore Street Davenport, Ia. 52804 563-324-1046 www.racedigitaldelay.com 1014-CTC WARRANTY AND DISCLAIMER DIGITAL DELAY INC. WARRANTS THE PRODUCTS IT MANUFACTURES AGAINST DEFECTS IN MATERIALS AND

More information

3 Inch & 4 Inch Digital Bypass Pressure Control Valves

3 Inch & 4 Inch Digital Bypass Pressure Control Valves SM64505 September 2008 Aerospace Group Conveyance Systems Division Carter Brand Ground Fueling Applicable addition manuals: None Maintenance & Repair Manual 3 Inch & 4 Inch Digital Bypass Pressure Control

More information

Technical Instructions. SQV Series Electromotive Valve Actuators. Document No

Technical Instructions. SQV Series Electromotive Valve Actuators. Document No Document No. 155-521 (For Use with 2-1/2-Inch to 6-Inch Pressure Independent Control Valves) Features Operating voltage: AC/DC 24V Application Control signals: 3-position, DC 0 to 10V, DC 4 to 20 ma Fail-safe

More information

C.A.S.E. AIR CARRIER SECTION POLICIES AND PROCEDURES

C.A.S.E. AIR CARRIER SECTION POLICIES AND PROCEDURES INTO-PLANE AUDIT CHECKLIST Audit Date: Allocation #: Station Code: City: Vendor Name: Address: Primary Contact: Title: Phone: Fax: E-mail: Auditor: Acceptable: Conditionally Acceptable Not Acceptable Register:

More information

XC Instrumentation System Owner s Manual Revision /05/06

XC Instrumentation System Owner s Manual Revision /05/06 XC Instrumentation System Owner s Manual Revision 3.0 07/05/06 XC INSTRUMENTATION SYSTEM OWNER S MANUAL 1 Revision History Date New Revision Level Revision Description 11/08/05 1.0 Initial release 05/24/06

More information

K10 Intrinsically Safe Electro-Pneumatic Positioner Operating Manual

K10 Intrinsically Safe Electro-Pneumatic Positioner Operating Manual K0 Intrinsically Safe Electro-Pneumatic Positioner Operating Manual Pneumatic Connection Outlet Port Gauge Single Acting Actuator (Spring Return): For single acting actuators Outlet Port 2 is to be plugged.

More information

VOLUMETRIC BLENDING SYSTEM OPERATION MANUAL

VOLUMETRIC BLENDING SYSTEM OPERATION MANUAL VOLUMETRIC BLENDING SYSTEM OPERATION MANUAL 12285 E. MAIN ST. MARSHALL, IL 62441 PHONE: 217-826-6352 FAX: 217-826-8551 WEB SITE: www.yargus.com 1 OPENING SCREEN The OPENING SCREEN is the screen that the

More information

Patient Lift Scale Indicator Owner s Manual

Patient Lift Scale Indicator Owner s Manual Patient Lift Scale Indicator Owner s Manual Item # 13046 INTRODUCTION Thank you for purchasing the Model PL600DM Patient Lift Scale Indicator. It has been manufactured with quality and reliability. This

More information

Intelli-Feed Controller User s Manual Intelli-Feed Digital Tachometer and Hourmeter

Intelli-Feed Controller User s Manual Intelli-Feed Digital Tachometer and Hourmeter Intelli-Feed Controller User s Manual Intelli-Feed Digital Tachometer and Hourmeter Part #: 9047 Table of Contents: Table of Contents 2 Intelli-Feed TM User Interface 3 Equipment Diagnostic Indicators

More information

SD Bendix M-21 and M-22 AntiLock Modulator Assembly DESCRIPTION M-21 MODULATOR M-22 MODULATOR

SD Bendix M-21 and M-22 AntiLock Modulator Assembly DESCRIPTION M-21 MODULATOR M-22 MODULATOR SD-13-4793 Bendix M-21 and M-22 AntiLock Modulator Assembly CONNECTOR DELIVERY (CAST-IN ID #2) (CAST-IN ID #3) DELIVERY (CAST-IN ID #2) (CAST-IN ID #1) DELIVERY DELIVERY (CAST-IN ID #1) CONNECTOR MOUNTING

More information

CS 420RC. Solid De-icer Controller Configuration and Set-up Manual

CS 420RC. Solid De-icer Controller Configuration and Set-up Manual CS 420RC Solid De-icer Controller Configuration and Set-up Manual 2/15 Table of Contents 1 Systems Modes of Operation 3 2 System Features 4 3 System Description 5 4 System Specifications 6 4.1 CS-420RC

More information

UTV-1000 Multi Gauge for Yamaha Rhino

UTV-1000 Multi Gauge for Yamaha Rhino IMPORTANT NOTE! This gauge has an hour meter and odometer preset option available only for the first 1.0 engine hour and 10 miles (16km). See ODO/HR PRESET for instructions. UTV-1000 Multi Gauge for 2004-2006

More information

R & D SPECIALTIES ROTROL I USER'S MANUAL

R & D SPECIALTIES ROTROL I USER'S MANUAL R & D SPECIALTIES ROTROL I USER'S MANUAL TABLE OF CONTENTS INTRODUCTION...2 SPECIFICATIONS...2 CONTROLS AND INDICATORS...3 TIME DELAYS...4 INSTALLATION...5 SYSTEM OPERATION...9 TROUBLESHOOTING...13 OPTIONAL

More information

Operation Guide. Operation Guide. Winnebago Hydraulic Leveling Systems by Kwikee. Introduction. Table of Content WARNINGS

Operation Guide. Operation Guide. Winnebago Hydraulic Leveling Systems by Kwikee. Introduction. Table of Content WARNINGS Operation Guide 05/07 Kwikee #1422192 Rev. 0F Table of Content Page Introduction 1 Safety Information 1 Operation 2 Control Panel 3 Manual Leveling 3 Automatic Leveling 3 Remote Operation 4 Stabilizing

More information

I.O.M. #081 updated : 09/19/2014 INSTRUCTION MANUAL INSTALLATION OPERATION MAINTENANCE. Covers Models with HE Series Instrument.

I.O.M. #081 updated : 09/19/2014 INSTRUCTION MANUAL INSTALLATION OPERATION MAINTENANCE. Covers Models with HE Series Instrument. I.O.M. #081 updated : 09/19/2014 INSTRUCTION MANUAL INSTALLATION OPERATION MAINTENANCE Covers Models with HE Series Instrument. 525 East Stop 18 Road Greenwood, IN 46142 317-887-0729 fax: 317-881-1277

More information