IWAKI Electromagnetic Metering Pump EW-Y Series Instruction Manual

Size: px
Start display at page:

Download "IWAKI Electromagnetic Metering Pump EW-Y Series Instruction Manual"

Transcription

1 IWAKI Electromagnetic Metering Pump EW-Y Series Instruction Manual Read this manual before use of product

2 Thank you for selecting the electromagnetic metering pump EW-Y series. This instruction manual deals with Safety Section Product outline Installation Section Operation Section and Maintenance Section. Please read through this manual carefully to ensure the optimum performance, safety and service of the EK series. Contents IMPORTANT INSTRUCTION... 1 Safety Instructions... 2 Outline Unpacking & Inspection Operation Principle Identification Codes Specifications External Dimensions Main Parts & Label Installation Before Use Notes on Operation Installation, Piping, & Wiring Operation Bleeding Flow rate Adjustment Operation Maintenance Causes of Trouble & Troubleshooting Maintenance & Inspection Disassembly & Reassembly Accessories Names of Parts & Structure This instruction manual should be kept on hand by the end user for quick reference. It is recommended that each user, after reading the instruction manual thoroughly, place it in a position close to the pump system and where it may be easily accessed by any user at any time whenever necessary.

3 Important Instructions For the Safe and Correct Handling of the Pump "Safety Instruction" section mentions important details about the handling of the product. Before the use of pump, read this section carefully for the prevention of personnel injury or loss. Observe the instructions accompanied with "WARNING" or "CAUTION" in this manual. These instructions are very important for protecting pump users from the dangerous situations. The symbols on this instruction manual have the following meanings: WARNING Nonobservance or misapplication of the contents of the Warning section could lead to a serious accident which may result in death. CAUTION Nonobservance or misapplication of the contents of the Caution section could lead to the personal injury to users or serious damage to the product. Types of Symbols Indicates that Warning or Caution must be exercised. Inside this triangle, a concrete and practical image provided as a warning or caution message is depicted. Indicates a prohibited action or procedure. Inside or near this circle, a concrete and practical image of the activity to be avoided is depicted. Indicates an important action or procedure which must be performed or carried out without fail. Failure to follow the instructions herein can lead to malfunction or damage to the pump

4 Safety instructions WARNING Turn off the power supply Working without disconnecting the power supply may cause an electrical shock. Before engaging upon any working procedures involving the pump, make sure to turn the power supply switch off and to stop the pump and other related devices. Electrical Shock Terminate operation When you detect or become aware of a dangerous sign or abnormal condition during operation, terminate the operation immediately and start it from the beginning again. For specified application only The use of a pump in any application other than those clearly specified may result in injury or damage to the pump. Use the pump strictly in accordance with the pump specifications and application range. No remodeling Never remodel a pump. Otherwise, a serious accident may result. Iwaki will not be responsible for any accident or damage of any kind which is caused by the user remodeling the pump without first obtaining permission or instructions from Iwaki. Prohibited No Remodeling Wear protectors If you touch or come in contact with any type of hazardous chemical liquid, including but not limited to chemicals, you may experience a serious injury. Wear protective gear (protective mask, gloves, etc.) during the pump operation. Operating site must be free of water and humidity The pump is not designed to be water-proof or dust-proof. The use of the pump in places where water splashes or humidity is high may result in an electrical shock or short circuit. Wear protective gear Prohibited CAUTION Qualified operators only The pump operator and pump operation supervisor must not allow any operators who have little or no knowledge of the pump to run operate the pump. Pump operators must have a sound knowledge of the pump and its operation. Prohibited Specified power only Do not operate the pump on voltage which is not specified on the nameplate. Failure to do so may result in damage or fire. Only the specified power level is to be applied. Prohibited - 2 -

5 Safety instructions CAUTION Do not run the pump dry Do not run the pump dry (without liquid inside the pump). Heat generated as a result of abrasion between elements inside the pump during operation without liquid may damage the inside of the pump. Prohibited Do not wet or dampen If an electric part or wiring gets wet with the liquid spilled over accidentally, a fire or electrical shock may be caused. Install the system in a place free from liquid spillage or leakage. Do not wet or dampen Ventilate Poisoning may result during an operation which involves toxic or odorous liquid. Ventilate the operating site sufficiently. Caution Spill-out accident Protective measures should be taken against any accidental spill-out or leakage of the operating liquid as a result of unexpected damage on the pump or the related piping. Caution Damaged pump Never operate a damaged pump. A damaged pump may cause leakage or electrical shock. Prohibited Do not damage power cable Do not scratch, damage, process, or pull the power cable forcibly. An extra load onto the cable, such as heating the cable or placing something heavy on the cable, may damage the cable and finally cause a fire or an electrical shock. Caution Arrange grounding Do not operate the pump without connecting the grounding wire. Otherwise, an electrical shock may result. Make sure the grounding wire is connected with the grounding terminal. Grounding Install an earth leakage breaker The operation of a pump without using an earth leakage breaker may cause an electrical shock. Please install an optional leakage breaker in the system. Electrical Shock Handling of power cable Use of a defective or damaged power cable may result in a fire or electrical shock. Handle the power cable carefully. Electrical Shock - 3 -

6 Safety instructions CAUTION Follow the instruction manual Replace the consumable parts by following the descriptions in the instruction manual. Do not disassemble any part of the pump if the disassembling procedure for the part in question is not included in the instruction manual. Limited operating site and storage Do not install or store the pump in the following places: * Places where a flammable gas or material is used or stored. * Places where the ambient temperature is extremely high (40 C or higher) or extremely low (0 C or lower). Prohibited osal of used pump osal of used or damaged pumps must be done in accordance with the relevant local laws and regulations. (Consult a licensed industrial waste products disposing company.) Frequent stop and start of pump should be done by using STOP function (ON and OFF of STOP terminal). If you can not use STOP function and are forced to operate pump by turning OFF and ON of power source, ON and OFF of power source should be limited to six times an hour

7 Outline 1.Unpacking & Inspection Operation Principle Identification Codes Specifications External Dimensions Main Parts & Label

8 Outline 1.Unpacking & Inspection After unpacking the pump, check the following points to ascertain that the product is exactly as you ordered. If you find anything wrong, please get in touch with your dealer. [1] Do the model, discharge pressure, voltage, etc., shown on the nameplate represent what you ordered? [2] Has the pump been damaged in transit? Are the bolts and nuts loose? 2.Operation Principle The Iwaki EW-Y series electromagnetic pump is a diaphragm metering pump of the 'linear electromagnetic drive system', which means electromagnetic force drives the diaphragm directly. It consists of a pump unit, a drive unit and a control unit. Reciprocating movement is caused by the electromagnetic force produced by the pulse current sent from the control unit, and the force of a spring. The reciprocating movement is transmitted to the diaphragm directly connected to a plunger, to change the capacity of the pump chamber. The changed capacity and the functioning of the valves in the pump unit drive the pump

9 3.Identification Codes Pump Identification EW - F 11 VC - 20E P Y 2 (1) (2) (3) (4) (5) (6) (7) (8) (9) Outline (1) Series code (2) Drive unit type Code Power consumption Stroke length F 16 W 1.25 mm G 24 W 1.5 mm (3) Diaphragm diameter Code Effective diameter [mm] (4) Wet end material Code Pump head Valve Valve seat Diaphragm Gasket VC CE FKM PVC VH HC EPDM PC CE FKM GFRPP PH HC EPDM PTFE/EPDM PTFE SH SUS316 HC SUS316 TC PVDF CE FKM (5) Material PVC : Transparent polyvinyl chloride GFRPP: Glassfiber reinforced polypropylene CE: Alumina Ceramic HC: Hastelloy C 276 FKM: EPDM: PTFE: Fluoroelastomer Ethylene propylene diene methylene Polytetrafluoroethylene SUS316: Austenite stainless steel PVDF: (6) Power source voltage Polyvinylidenefluoride Code Power source Frequency (Hz) 20E AC220/230/240V 50/60-7 -

10 Outline Power cord Code No code P Cord end Crimp-style terminals With plug Controller code Y : Y type controller Connection hose Code Hose diameter 2 ø4 ø6 3 ø6 ø8 5 ø9 ø12 6 ø10 ø12 9 Rc1/4 (Female) 23 ø6 ø12 25 ø5 ø8 Special version code 4.Specifications Pump specifications <VC, VH, PC, PH> Model Max. discharge capacity L/H (ml/min) Discharge capacity/shot ml Max. discharge pressure MPa Stroke rate spm Stroke length mm EW-F ( 26) EW-F ( 42) EW-F ( 60) EW-F (150) EW-G ( 78) EW-G (165) EW-G (252) EW-G (400)

11 Outline <SH, TC> Model Max. discharge capacity L/H (ml/min) Discharge capacity/shot ml Max. discharge pressure MPa Stroke rate spm Stroke length mm EW-F ( 26) EW-F ( 40) EW-G ( 78) EW-G (165) EW-G (230) EW-G46 SH : 22.8 (380) TC : 24.0 (400) SH : TC : NOTE 1: NOTE 2: NOTE 3: NOTE 4: NOTE 5: NOTE 6: The table shows the results of tests with clear water at the rated voltage and normal temperature. The maximum flow rate is the figures at the max. discharge pressure, max. stroke frequency and at full stroke length. At a lower pressure, the discharge flow is larger than shown in the table. Liquid temperature: C (VC, VH : C) Permissible voltage fluctuation: Within ± 10% of rating Self priming height is 1m in the above mentioned operating and liquid conditions. Max. discharge pressure when pumping liquid at temperature 0 to -10 C is limited to 70% of rated max. discharge pressure shown on above table

12 Controller specifications Operation Mode lay Keypad Control function Input Output Environmental specifications (1) Ambient temperature : 0-40 C (2) Ambient humidity : 35% - 85% RH (Condensation should not be generated in the controller.) (3) Storage temperature : C Sound level MAN spm EXT DIV(Dividing) MULT(Multiply) ANA R(Analog, rigid) ANA V(Analog, variable) / , 0-20, 20-4, 20-0 ma 2points mA range 1-180spm One function can be selected among above 4 functions. LCD 14seg 5digit spm, Capacity, Alarm, etc ON Green Green lights when power is put and blinks while operating. LED Orange lights when Pre-STOP is activated, and red STOP Orange/Red when STOP is activated. OUT Red Red lights when OUT1 is activated. 5 Keys START/STOP, UP, DOWN, EXT, DISP STOP Pump keeps running when Pre-STOP is activated. Pump stops when STOP is activated. Prime Pump runs at max. spm while up and down keys are pushed. Key lock Key can be locked and unlocked. Calibration(to display by flow rate in place of spm) Counting number of shot Flow check Buffer memory Pulse Current Level sensor Flow counter Outline To show by flow rate in place of spm display, discharge capacity per shot is calculated by operating pump and by measuring pumped volume at CAL mode. (See page 50 CAL setting ) To count or clear number of shot. Usable when flow counter is connected and set to ON. Alarm indication and output are possible at the time of ERROR. ON/OFF is possible. Set at OFF when shipped. OVER is indicated while being put in memory. Max pulses are put in memory. Potential free contact or open collector, Max. 100Hz DC0-20mA (Input resistance 200 ) Potential free contact or open collector, 2-steps contact. Open collector (With DC12V power output) Mechanical relay AC250V 2A Output Pre-STOP, STOP, Count UP, Flow alarm 1 STOP is standard. One or more can be selected among above as option. Photo-MOS relay AC/DC24V 0.1A Output Pre-STOP, STOP, Synchronous with stroke, Count UP, Flow alarm, Pump operation 2 Synchronous with stroke is standard. One can be selected among above as option. NOTE: When OUT 1 and OUT2 are used at the same time, voltage is limited to AC/DC24V. The sound level of the each type of the pump is 70 db (A scale) or less at a distance of one meter

13 Outline 5.External Dimensions EW-F11,F16, F21 G21 Types (VC, VH, PC, PH, TC) (254.5) (37) OUT AIR IN (67.5) (36) 100 (160) (194) (22.5) EW-F31, G31 Types (VC, VH, PC, PH, TC) (235.5) IN OUT 10 (18) 100 (182) (67.5) 125 (24.5)

14 Outline EW-G36 Type (VC, VH, PC, PH, TC) (235) 16 (67.5) 125 EW-G46 Type (VC, VH, PC, PH, TC) (237) IN 10 (13) 100 (187) OUT IN 10 (18.5) 100 (181.5) OUT (24) (67.5) (26)

15 Outline EW-F11, F16, G21 Types (SH) (231.5) (15) Rc1/4 (9) OUT IN (67.5) (44) 100 (155) (201) (21.5) EW-G31 Type (SH) (233) 15 Rc1/4 (9) OUT IN 10 (34) 100 (167) (213) (67.5) 125 (23)

16 EW-G36 Type (SH) (233) Outline 15 Rc1/4 (9) (67.5) EW-G46 Type (SH) (235) 15 Rc1/4 (9) OUT IN 10 (27) 100 (174) (220) IN 10 (31.5) 100 (169.5) (215.5) (23) (67.5) (25)

17 Outline 6.Main Parts & Label Air vent adjusting screw Label for controller operation Driving unit Air vent port Make sure to connect a tube to return removed air hack to the suction-side tank. Control unit Discharge port Nameplate label Pump unit Operate the pump in accordance with the specifications mentioned in the label. Suction port Base Make sure to fix the base by fastening screws

18 Installation 1.Before Use Notes on Operation Installation, Piping, & Wiring

19 Installation 1.Before Use Strictly observe the following points. Operators and maintenance service staff must read the instruction manual thoroughly before using the products. Do not operate the pump system unless all of the contents in the manual are completely understood. CAUTION Turn off the power supply Working without disconnecting the power supply may cause an electrical shock. Before engaging upon any working procedures involving the pump, make sure to turn the power supply switch off and to stop the pump and other related devices. Terminate operation When you detect or become aware of a dangerous sign or abnormal condition during operation, terminate the operation immediately and start it from the beginning again. Specified power only Do not operate the pump on voltage which is not specified on the nameplate. Failure to do so may result in damage or fire. Only the specified power level is to be applied. Keep from heat or flame Do not place any dangerous materials or flammable objects near the pump for the prevention of fire or accident. Damaged pump Never operate a damaged pump. A damaged pump may cause leakage or electrical shock. 2.Notes on Operation Dropping the pump or subjecting it to strong impacts may result in faulty performance. Handle the pump with care

20 Installation The pump can be operated outdoors, as the pump employs a simple water and dust proof structure. However, when installing the pump, avoid places exposed to direct sunlight or direct rain with an ambient temperature of above 40ºC, or with a relative humidity of above 85%. Though the pump has a simple waterproof and dustproof structure, a sheltered location is recommended. Select an installation site convenient for future maintenance and inspection, and fix the pump on a level floor so that it is free of vibrations. Ventilate Ventilate the operating site sufficiently when toxic or odorous liquid is handled. Prohibited Do not wet or dampen If an electric part or wiring gets wet with the liquid spilled over accidentally, a fire or electrical shock may be caused. Install the system in a place free from liquid spillage or leakage. Install an earth leakage breaker The operation of a pump without using an earth leakage breaker may cause an electrical shock. Please install an leakage breaker in the system

21 Installation Prohibited Limited operating site and storage Do not install or store the pump in the following places: * Places where a flammable gas or material is used or stored. * Place where the ambient temperature is extremely high (40ºC or higher) or extremely low (0ºC or lower). Cleaning Wiping the pump body or the nameplate with a cloth soaked in a solvent such as benzene, thinner or kerosene may remove or change the color of the coating. Use a dry cloth or a cloth soaked in water or neutral detergent

22 3.Installation, Piping, & Wiring Installation CAUTION When you detect or become aware of a dangerous sign or abnormal condition during operation, stop the operation and restart the procedure from the beginning. Installation [1] Installation Install the pump at a site where the ambient temperature does not exceed 40ºC and the relative humidity does not exceed 85%. (There should be no dew condensation inside the control unit.) The site must be selected keeping in mind ease and efficiency for maintenance and inspection work. [2] Place the pump as close to the suction tank as possible, allowing a flooded suction system (where the pump is located lower than the suction-side tank). Caution [3] If the pump is used to feed liquid that generates air bubbles easily (sodium hypochlorite, hydrazine solution, etc.), it must be positioned in a cool, dark place away from direct sunlight. Side view of tube [4] Anchoring pump Select a level floor free of liquid splash, and use M5 screws to firmly anchor the pump so as not to allow any vibration. If the pump is inclined, the discharge volume may be decreased considerably and may lose prime. [5] Preparation of tube Before the installation of the pump, cut the ends of the tube squarely

23 Installation Tube Fitting nut Connecting port Piping <For material codes VC, VH, PC, PH, TC> [1] Piping for pump connection port Use the tube with the correct diameter and make sure the connecting section does not cause liquid leakage or air suction. CAUTION Since the fitting nut is made of plastic resin, do not fasten it too tightly. This may destroy the part. [2] Piping for air elimination process For the safety, connect a tube to the discharge port of the air vent unit so that the eliminated air can be discharged into the suction tank or like. [NOTE] The F31, G31, G36 and G46 types are not equipped with an air vent unit. Discharge port Rc 1/4 Male connector Lock nut Suction port Rc 1/4 Air vent body A <For material code SH> 1) Connection port is Rc1/4 female threads. Use proper size of pipe and securely connect pipe so that liquid can not leak or air can not be sucked in. 2) Screw the attached male connector in the bleed port. 3) Connect hose of 4 mm dia. to the male connector. Return the hose end to the tank. 4) Adjust the direction of discharge port to any desired direction. a. Turn the lock nut to left with wrench. b. Adjust the direction of discharge port. c. Holding the air vent body A by hand, turn the lock nut to right to tighten it. d. Turn the lock nut to left by one fourth turn with wrench

24 Installation CA Type Check Valve [3] Installation of check valve (Optional accessory) The check valve is used to prevent overfeeding. The check valve must be installed in any of the following cases. (1) In case the suction-side liquid level is higher than that of the discharge-side level. (Liquid level is opened to atmosphere.) (Fig. A) (2) In case the pressure on the suction side is higher than on the discharge side (Fig. B) (3) In case the discharge-side liquid level is higher than that of the suction-side and the difference of the two levels is 5 m or less (Fig. C) Suction side Fig. A Discharge side (4) In case loaded pressure (piping resistance, discharge head, etc.) applied on the pump is 0.13 MPa or less. (0.049 MPa or less for F31, G36, G46) Install the check valve at the end of the dischargeside plumbing. It must be 1 m or more away from the pump. Fig. B Fig. C CAUTION As CA type uses Hastelloy spring at wet end, CA type could not be used for chemicals (Hydrochloric acid etc) which corrode Hastelloy. Select BVC type for this application

25 Installation Wiring of external signal cord Procedure to connect the signal cord Use DIN connector of five poles and four poles. Following connectors made by Binder in Germany are recommended. Ask IWAKI for the detail of Binder connector. 5 poles : 713 series for input signal 5 poles : 715 series for flow counter 4 poles : 715 series for level sensor Following connector made by Hirschmann in Germany is recommended. Ask IWAKI for the detail of Hirschmann connector. 4 poles : GDS307 for output Following procedures are based on the connector made by Binder and Hirschmann. If a similar connector is used, the wiring should be made according to the instruction manual of the manufacturer of connector. CAUTION Only qualified operators/service staff should be in charge of the related electrical arrangement and control of the power source. Failure to observe this instruction may result in injury to person or damage to assets. Never do the wiring when the power is switched on and the pump is operating to avoid electrical shock to the person and pump damage. Precautions on wiring *Do not tie up wires for signals with power cord nor with wires for relay output. * Do not share the pump power with that of strong power equipment which generates surge voltage.otherwise pump controller may be failed. Frequent stop and start of pump should be done by using STOP function (ON and OFF of STOP terminal). If you can not use STOP function and are forced to operate pump by turning OFF and ON of power source, ON and OFF of power source should be limited to six times an hour. In case of Binder connector (1) Disassemble the connector and pass the wire through it. Cable out side diameter to be used is ø4-6. If other diameter cables are used, the connector can not seal properly. (2) Strip the wire ends and insert them to the appropriate positions and tighten them by screws. Max. allowable cross section of the wire is 0.75mm 2. (3) After the screws are tightened, tighten other parts securely. Slightly pull the cord confirm that the cord tightly secured. If the cord is loose, perfect sealing can not be obtained

26 Installation In case of Hirschmann connector (1) Disassemble the connector and pass the wire through it. Insert a minus screw driver into the place shown by LIFT and lift it up. Cable out side diameter to be used is mm dia. Other diameter cables can not seal properly. (2) Strip the wire ends and insert them to the appropriate positions and tighten them by screws. Max. allowable cross section of the wire is 0.75mm 2. (3) After the screws are tightened, tighten other parts securely. Slightly pull the cord confirm that the cord tightly secured. If the cord is loose, perfect sealing can not be obtained. Terminal position Pre-STOP OUT1 N/A STOP Pulse COM1 COM2 12V OUT2 COM3 N/A ANA 12V N/A N/A FC N/A Not Applicable Connection of level sensor The controller corresponds to two stage level sensor. Connect pre-alarm signal to Pre-STOP and alarm signal to STOP. When the pre-alarm signal comes in, orange lamp is lighted but the pump does not stop. When one contact type is used, connect wires to STOP and COM2. For open collector output level sensor Pay attention to the polarity. Pre-Stop and STOP are plus (+), and COM2 is minus (-). (Max. charged voltage 5V, Current 1.8mA) For contact output level sensor Use the one designed for electronic circuit and minimum applicable load of 1mA or less Connection inside connector 1 : STOP 2 : Pre-STOP PUMP 3 : Free 4 : COM2 Level Sensor (STOP) ON CLOSE OPEN Stop function Stop function means the function to stop the pump by external signal. Connect the wires to STOP and COM2 that is the same way as the level sensor connection. CAUTION Frequent stop and start of pump should be done by using STOP function (ON and OFF of STOP terminal). If you can not use STOP function and are forced to operate pump by turning OFF and ON of power source, ON and OFF of power source should be limited to six times an hour

27 Installation Pulse signal input Pulse signal input is used when the pump is operated with DIV or MULT function in EXT mode. DIV means dividing and MULT means multiply. In case of open collector signal Pay attention to the polarity. Pulse is plus (+), and COM1 is minus (-). (Max. charged voltage 5V, Current 1.8mA) In case of contact signal Use the one designed for electronic circuit and minimum applicable load of 1mA or less. 2 Connection inside connector: : Free 2 : Pulse 4 3 : Free 4 : 12VDC 5 : COM1 Analog signal input Analog signal input is used when the pump is operated with ANA.R or ANA.V function in EXT mode. ANA.R means analog, rigid and ANA.V means analog, variable. 2 Connection inside connector: : ANA 2 : Free 4 3 : Free 4 : Free 5 : COM1 Flow counter input Flow counter input is used when the pump is operated with FCP flow counter. When flow counter is used, setting is needed at USER mode. OUT POWER COM 2 Connection inside connector: 1 : FC 2 : 12VDC FCP : Free 4 : Free 5 : COM3-25 -

28 Installation Output signal OUT1 : Relay output Standard is STOP output: Output is activated when pump stops because of external signal which comes from level sensor or so. OUT2 : Photo MOS relay output Standard is output synchronous with stroke : Output is activated synchronous with each pump stroke. NOTE) In case both OUT1 and OUT2 are used simultaneously, both are limited to AC/DC24V or lower. OUT OUT1 Connection inside connector: 1 : OUT2 2 : OUT1 3 : OUT1 4 : OUT2 Output function of OUT1 and OUT2 can be changed by setting Surge voltage The electronic circuit of the control unit may be affected by excessively high surge voltage. So, do not operate the pump near high-power electrical equipment of 200V or above that generates high surge voltage. Under unavoidable circumstances, take either of the following measures. (1) Use a surge absorbing element (such as a varistor with surge resistance of 2000A or more) at the pump power supply connection. (2) Use a noise-cut transformer

29 Operation 1.Bleeding Flow rate Adjustment Operation

30 Operation After the installation, piping, and wiring processes are completed, operate the pump in accordance with the following steps. CAUTION Do not operate the pump with a completely closed discharge-side valve. Operating the pump with the discharge-side valve fully closed may lead to liquid leakage or pipe rupture. Make sure not to operate the pump with the discharge-side valve closed. Do not run the pump dry. A pump which has been run dry may experience liquid leakage during its liquid feeding operation. Make it sure to run the pump after supplying liquid inside the pump. * Dry operation of the pump over a long time may cause the pump to overheat and the pump unit (pump head, valve case, etc.) to become deformed or the pump head attachment to become loose, which may result in liquid leakage trouble. Keep the pump head firmly assembled. If the installation bolts on the pump head are loosened, liquid leakage may result. * Fasten the 4 hex,socket bolts tightly before starting the initial pump operation. (The bolts may be loosened during storage or transportation of the pump, depending upon the condition of each.) * Fastening torque: 2.16 N m for EW-11, 16 & 21, 2.55N m for EW-31, 2.95N m for EW- 36, 46. Tighten all the bolts fully by applying an equal amount of torque in a diagonal order among the bolts. Frequent stop and start of pump should be done by using STOP function (ON and OFF of STOP terminal). If you can not use STOP function and are forced to operate pump by turning OFF and ON of power source, ON and OFF of power source should be limited to six times an hour. 1.Bleeding Bleeding is a process undertaken to eliminate air inside the suction-side tube and the pump head. Make sure to carry out bleeding prior to the initial operation of the pump and/or after replacing the liquid in the tank. For safe bleeding, first set a pipe to the air-vent port of the air vent unit. WARNING Some liquids used in pump feeding may cause skin trouble or affect the quality of a mechanical part. Wipe off the liquid immediately when it wets your hand or a mechanical part. VC, VH, PC, PH, TC types Air vent port Air vent adjusting screw <Bleeding for EW-F11, 16, 21 and G21> [1] Start the pump. See the clause "Operation" to operate the pump. [2] Rotate the air vent adjusting screw counterclockwise (almost half a turn) to open the air vent port. [3] Operate the pump under this condition for longer than 10 minutes for a complete removal of air

31 Operation SH type Male connector Air vent adjusting screw [4] Rotate the air vent adjusting screw clockwise to close the air vent valve [5] Inspect various points for liquid leakage to complete the air elimination process. <Bleeding for EW-F30, G30, 35, 45 models> [1] Extend the tube connected with the discharge-side fitting nut of the pump to the liquid tank or something like a drain plate. Then, start pump operation. Remove the check valve if it is installed on the discharge-side. Check valve should be removed. Fitting nut To tank or drain plate Pump head [2] Adjust the stroke rate to full speed, and continue operating the pump for about 10 minutes to eliminate the air completely. [3] When the air in the pump head is completely eliminated and replaced with liquid, return the discharge-side tube to the regular piping position. [4] Finally, make sure there is no leakage in any section

32 Operation 2.Flow rate Adjustment The discharge amount can be adjusted by two methods, namely, stroke speed adjustment and stroke length adjustment, the former being used in most cases. In the event the expected discharge is not exactly obtained by the stroke speed adjustment, the stroke length adjustment is employed as a supplementary. Flow rate 100 % Fixed stroke rate 180 spm (Stroke rate fixed at 100%) 135 spm (Stroke rate fixed at 75%) 90 spm (Stroke rate fixed at 50%) [1] Procedure for flow rate adjustment Determine the appropriate stroke rate and stroke length based on pump operation conditions and liquid properties. The following method is recommended to determine the set values in consideration of pump per- 25 formance features % Stroke length adjustment (1) Set the stroke length at 100% and then adjust the stroke rate so that an approximate discharge amount is arranged. (2) Measure the discharge amount. (3) If the discharge amount actually measured is lower than required, increase the stroke rate. Then, measure the discharge amount again. (4) Adjust the stroke length, this time for the purpose of fine adjustment of the discharge amount. (5) Measure the discharge amount and check that the set amount is precisely discharged. Flow rate 100 % Fixed stroke length [2] Adjustment of stroke rate See the clause "Operation" to change stroke rate. The stroke rate per minute of the plunger is controlled by the control unit within a range of spm spm Stroke rate adjustment

33 Operation [3] Adjustment of stroke length Stroke length can be adjusted by changing the degree of plunger return. (1) Start the pump and rotate the stroke length adjusting dial while operating the pump to adjust the discharge amount. Flow rate 100 % Fixed stroke rate % Stroke length adjustment (2) The relation between discharge amount and stroke length is as shown in the graph on the left, where the discharge amount is indicated in percentage. The degree of plunger is variable in a range from 0 to 100%. Nevertheless, the usage between 40% and 100% is practical. CAUTION Do not rotate the stroke length adjusting dial when the pump stops. Notice (1) For the liquids that easily generate air bubbles (sodium hypochlorite, hydrazine solution etc.), the flow rate should be adjusted by changing the stroke rate keeping the stroke length at about 100%. If stroke length is short, desired flow rate may not be obtained. (2) If the back pressure on the discharge side is high, adjust the flow rate by changing stroke rate keeping the stroke length at about 100%. In the application of neutralization or titration etc., if the reaction is greatly influenced by the volume per shot of pump, adjust the flow rate by stroke rate adjustment keeping the short stroke length to minimize the volume per shot

34 Operation 3.Operation OPERATION FUNCTION Manual operation Set number of stroke with UP and DOWN keys, and start and stop pump with START/STOP key. Stroke rate can be adjusted either pump is running or stops. If flow rate calibration is done at CAL mode, the flow rate can be set in place of stroke rate setting. Press Press Press Start/Stop key Run Run Operation Stop Pulse dividing operation Pulse dividing operation is done by external pulse signal. Dividing ratio can be set for 9999:1 to 1:1. Max. stroke speed at pulse dividing operation is 180 spm. If pulse signals exceeding the max. number of strokes are put in, the excessive number of strokes can be put in memory up to 65,535. Dividing example / 4 EXT. Pulse Pump stroke Pulse multiply operation Pump automatically stops after it makes 1 to 9999 counts by one external pulse signal. Stroke speed is that set for manual operation. Number of strokes corresponding to the pulses which are input while multiply operation can be put in memory up to 65,535. Multiplying example 4 EXT. pulse Pump stroke

35 Operation Analog input operation 1) In case of ANA. R Mode It makes spm operation in proportion to 0~20 ma range current signal. Available are four patterns of 4-20, 20-4, 0-20 and In case 4-20 and 20-4 are selected, the disconnection detection function automatically operates to stop pump if amperage becomes less than 4 ma and DISCN sign blinks. When this function operates, check wiring. To release this function, push START/STOP key. 180 Illustration on left shows the case of setting as below. spm (4) (3) (2) (1) 4-20 ma (2) 20-4 ma (3) 0-20 ma (4) 20-0 ma (1) ma 2) In case of ANA. V Mode It makes spm operation in proportion to 0-20mA range current signal. By setting two points, it automatically draws straight line. Depending on setting, it happens it does not come to 0 spm at 0 ma. If it exceeds 180 spm, pump stroke is fixed at 180 spm spm P2 Illustration on left shows the case of setting as below. P1 = 6mA, 60spm P2 = 17mA, 160spm 60 P ma

36 Operation CONTROL PANEL lay Set value and operating condition are displayed. Mode indicator Unit indicator START/STOP key Key to start and stop pump in the manual operation mode. MAN N DIV MU LT ANA. R V P! spm UP key Key to increase the spm and to change the set value. EXT key Key to set pump for external input operation. EXT m L /h ma OVER P1 2 LOCK Er r DOWN key Key to decrease the spm and to change the set value. ON lamp Lamp lights when the power is on and blinks synchronous with pump stroke during the operation. STOP lamp Orange color lights when a Pre- STOP signal comes in from level sensor and red color lights when STOP signal comes in. ON STOP Status indicator DISP OUT DISP key To interchange spm and flow rate display. OUT lamp Lamp lights when OUT1 turns on. BASIC DISPLAY MAN spm It shows 180 spm at MAN mode. AN A. V L/h It shows flow rate during current proportional operation at EXT mode. MULT Setting number of shots for multiply operation at EXT mode. DIV spm Pump stops by STOP input at pulse dividing operation of EXT mode

37 Operation OVERVIEW OPERATING SCHEME Power on CAL mode DISP 3sec WAIT mode EXT 3sec USER mode EXT EXT EXT Set mode EXT EXT mode MAN mode OUT1 EXT OUT2 FL. CHK ANTI. C b. MEM T. C 1. means automatic transfer. When the power is switched on for the first time, it comes to WAIT mode. On and after next time, it comes to the status at which the power is switched off. 2. At MAN operation, pump starts operation by pushing START/STOP key at wait mode. Push START/STOP key again to come back to wait mode to stop pump. 3. Push EXT key at wait mode to come to EXT mode and to start operation. Push START/STOP key to return wait mode to stop pump. 4. Each setting for EXT operation can be done by pushing EXT key at EXT setting mode. After setting is finished, return to EXT mode by EXT key to execute EXT operation according to changed setting. 5. Push DISP key three seconds to change from WAIT mode to CAL mode. CAL mode enables flow rate indication in place of spm indication by inputting actually measured flow rate. 6. Push EXT three seconds to change from WAIT mode to USER mode. At USER mode you can do detailed setting such as mode selection of EXT operation and setting of output or so. For details refer to item Operation

38 Operation DISPLAY ELEMENTS a b c d e o f MAN DIV MULT ANA. R V P! spm p L /h g ma OVER P12 LOCK Err h n m l k j i a : MAN Pump is operating at MAN mode. b : DIV Pump is operating at pulse dividing operation at DIV mode EXT. c : MULT Pump is operating at multiplying operation at MULT mode EXT. d : ANA. R V It shows analog input operation. ANA.R is pre-fixed and ANA.V is free two points setting. e : Flow counter is used and it lights and blinks when pulse signal is input. f : spm It shows spm indication. g : L/h It shows liter/hour or Liter indication. h : ma It shows amperage figure at analog setting. i : It shows the controller is in setting mode. j : It lights when flow rate and spm indications can be interchanged. k : Err It lights when error happens. l : LOCK It lights when key is locked. m: P12 At ANA.V setting, it lights when two points are indicated. P1 lights for the first point and P2 lights for the second point. n : OVER It lights when stroke is fixed to 180 spm because the stroke exceeds 180 spm by the calculation for analog input operation and when it is buffered at DIV or MULTI mode when buffer memory is ON. o :! It lights as caution purpose when pump is in continuous self-priming operation. p : Operation condition and set value are shown as figures or letters

39 OPERATION Operation CAUTION Before turn on pump, check the nameplate on pump if you are putting correct power on pump. Strictly prohibited is other power than shown on pump nameplate is put on pump. Otherwise pump is failed or damaged. Turn on power spm When the power is turned on initially, the display shows the version of software and goes to wait mode. On and after the second time, it comes to the mode at which the power was turned off last time. (If power is off at setting mode, it comes to wait mode first. At wait mode, stroke speed is shown. Lamp lights. (Green) Manual operation (1) Start & stop (in manual operation) MAN spm At wait mode, push START/STOP key once to start manual operation. ON lamp blinks synchronous with pump stroke. Push again START/STOP key and ON lamp lights to come to wait mode. MAN (2) Change of stroke speed Stroke speed is adjusted by UP key and DOWN key. Figure increases by UP key and decreases by DOWN key. If you push key continuously, the figure changes quickly. Stoke speed can be changed while pump runs or stops (wait mode). MAN spm Flow rate can be set in place of stroke speed. Push DISP key to change display. To set for flow rate display, calibration in CAL mode must be done in advance. See the item CAL mode. Push again DISP key to return spm display. EXT operation spm (1) Move to wait mode Move to wait mode if it is in other mode than wait mode. Go to next step if it is in wait mode. ANA. V spm (2) Push EXT key and it comes to EXT mode and pump starts operation of the EXT function which was decided at USER mode. At the time of shipment from factory, it is set for ANA. V mode which is analog input operation. If other control function is used, change it with mode selection of USER mode. Picture on left shows ANA. V mode

40 Operation ANA. V L /h At this display you can change to flow rate display by pushing DISP key. If you push DISP key while flow rate is displayed, it changes to spm display. ON lamp blinks simultaneous with pump stroke. Push START/STOP key to come to wait mode. DIV spm (3) In DIV mode (dividing function), display shows as left. To change to dividing function, you need to change setting at USER setting. See item change of EXT mode of USER set- ting. At this display you can change to flow rate display by pushing DIV DISP key. If you push DISP key while flow rate is displayed, L /h it changes to spm display. ON lamp blinks simultaneous with pump stroke. Push START/STOP key to come to wait mode. (4) MULT mode of count control is displayed as picture on left. MULT Pre-set number of stroke is shown until start signal comes and the figure is reduced by one every time pump shots one stroke. To change to count control, setting must be changed in USER setting. See item change of EXT mode of USER setting. MULT L Remaining volume can be displayed by pushing DISP key. (Remaining volume of batch to be discharged = number of shot volume per shot) Push DISP key to change to display by number of stroke. ON lamp blinks synchronous with pump stroke. Push START/STOP key to come to wait mode. ANA. R spm (5) Picture on left is ANA. R mode (analog rigid). To change to ANA. R mode, setting must be changed in Di sp USER setting. See item EXT mode change of USER setting. ANA. R L /h Flow rate can be displayed by pushing DISP key. To change to spm display, push DISP key at flow rate display. ON lamp blinks synchronous with pump stroke. To come to wait mode, push START/STOP key

41 Operation EXT setting ANA. V mode setting ANA. V (1) It comes to ANA. V setting mode by pushing EXT key at ANA. V mode of EXT operation. P1 ma This is to explain how to set two points of electric current and stroke speed. First of all, set current value at P1. Figure increases by push- ANA. V spm ing UP key and decreases by DOWN key. If you continue to push it, figure changes quickly. Push EXT key to move to next setting. P1 (2) Set stroke speed at P1. Figure increases by pushing UP key and decreases by pushing DOWN key. If you continue to push it, figure changes quickly. ANA. V Flow rate can be displayed by pushing DISP key. L /h To change to spm display, push DISP key again. Push EXT key to move to next setting. P1 ANA. V (3) Set current at P2. Figure increases by pushing UP key and decreases by pushing DOWN key. If you continue to push it, P 2 ma figure changes quickly. Push EXT key to move to next setting. ANA. V spm (4) Set stroke speed at P2. Figure increases by pushing UP key and decreases by pushing DOWN key. If you continue to push it, figure changes quickly. P 2 ANA. V L /h P 2 Flow rate can be displayed by pushing DISP key. To change to spm display, push DISP key again. Push EXT key to memorize set value and to return to ANA. V mode operation. DIV mode setting DIV (1) It comes to DIV setting mode if you push EXT key at DIV mode of EXT operation. This is to explain how to set dividing ratio. Figure increases by pushing UP key and decreases by pushing DOWN key. If key is pushed continuously, figure changes quickly. Push EXT key to memorize set value and to return DIV function operation

42 Operation MULT mode setting MULT MULT (1) Push EXT key at MULT mode of EXT operation to come to MULT setting mode. This is to explain how to set number of strokes. Push UP key to increase figure and DOWN key to decrease figure. Figure changes quickly if key is pushed continuously. L Push DISP key to change to flow rate display. Push DISP key again to change to stroke number display. Push EXT key to memorize set value and to return to MULT control operation. ANA. R mode setting ANA.R ma (1) It comes to ANA. R setting mode by pushing EXT key at ANA. R mode of EXT operation. This is to explain how to select pattern of analog function. Push UP and DOWN key to select 4-20, 20-4, 0-20 & Push EXT key to memorize set value and to return ANA.R function operation

43 USER setting Operation Setting of each function can be changed at USER mode. Following is a operation flow. EXT 3 seconds EXT (1) DISP ANA. V ANA. R MULT DIV OUT1 (2) DISP PST-N PST-Y DISP STP-N STP-Y DISP C. UP-N C. UP-Y DISP P. RUN F. AL OUT2 (3) DISP C. UP SPM STOP PrST FL. CHK DISP C. MODE b. MODE DISP 10 (4) A. MODE OFF DISP DISP MECH DISP ST50 ST20 ANTI. C (5) DISP ELEC DISP ST05 FT04 FT02 DISP FT01 b. MEM (6) DISP MEM-N MEM-Y T. C (7) DISP

44 Operation User mode can be attained from wait mode. spm (1) Move to wait mode If it is in other mode than wait mode, move it to wait mode. If it is in wait mode, go to next. ANA. V (2) Continue to push EXT key for more than 3 seconds and it comes to USER setting mode. Items changes by pushing UP and DOWN key. Select necessary item. (1) Setting EXT functions Any one of DIV(pulse dividing), MULT(pulse multiply), ANA.R(analog, rigid) or ANA.V(analog, variable) can be selected for EXT operation mode. Initial function when shipped from factory is ANA.V. spm (1) Move to wait mode If it is in other mode than wait mode, move it to wait mode. If it is in wait mode, go to next. ANA. V (2) Continue to push EXT key for more than 3 seconds and it comes to USER setting mode. lay shows it is in EXT setting mode. (3) Push DISP key to show the mode currently set. sign lights to show that change of function setting is now possible. Illustration on left shows it is in ANA. V mode. (4) Push once DOWN key to come to ANA. R mode. Push UP or DOWN key to select desired mode. (5) Push once DOWN key to come to MULT mode. Push UP or DOWN key to select desired mode. MULT (6) If desired mode is selected, push once DISP key and it returns to EXT mode setting sign. If you wish to select EXT operation mode only, push here START/STOP key to return wait mode

45 Operation (2) Setting of output function to OUT1 (relay output) ON or OFF of PST(Pre-STOP), STP(STOP) and C.UP(count-up) can be selected. Output is activated to OUT1 when the function set here operates. Initial setting at factory shipment is ON (STP-Y) for STP and all others are OFF. PST-Y Signal is output when signal from level sensor is input to Pre-STOP terminal. STP-Y Signal is output when signal from level sensor is input to STOP terminal. C.UP-Y At MULT operation, signal is output when set number of stroke is completed. Signal is output even when pump stops. NOTE: ON and OFF of functions can be selected independently and plural functions can be set to ON(- Y), However, you can not distinguish which function operates to output. spm (1) Move to wait mode If it is in other mode than wait mode, move it to wait mode. If it is in wait mode, go to next step. ANA. V (2) Push EXT key continuously for 3 seconds or more to come to USER setting mode. lay shows it is in EXT mode. (3) Push DOWN key once and display shows OUT1. (4) Push DISP key once to come to Pre-STOP. - N means output is not activated. (5) To change setting, push UP or DOWN key. - Y means that output is activated. (6) Push DISP key to go to next setting of STOP. - Y means that output is activated. (7) To change setting, push UP or DOWN key. - N means that output is not activated

46 Operation (8) Push DISP key to go to next setting of Count-up. - N means that output is not activated. (9) To change setting, push UP or DOWN key. - Y means that output is activated. (10) Push DISP key to come out from setting and return to OUT1 display. 3) Setting of output function to OUT2 (Photo MOS relay) One function can be selected among PrST(Pre-STOP), STOP, spm (synchronous with spm), C.UP (count-up), F.AL (flow alarm) and P.RUN (pump running). When a function set here operates, output is activated to OUT2. spm is selected when shipped from factory. PrST : Output is activated when a signal from level sensor is input to Pre-STOP terminal. STOP : Output is activated when a signal from level sensor is input to STOP terminal. spm : Output is activated synchronous with pump stroke. C.UP : At MULT operation, output is activated when number of set stroke is completed. F.AL : By setting flow check, output is activated when pump stops automatically. P.RUN: Output is activated when pump is in operating condition. Output is activated when pump is running at MAN mode and EXT mode, or when pump is waiting input signal. Output is not activated when STOP function operates or when error happens. Also output is not activated in PRIME condition although pump is running. spm (1) Move to wait mode If it is in other mode than wait mode, move it to wait mode. If it is in wait mode, go to next step. ANA. V (2) Push EXT key continuously for 3 seconds or more to come to USER setting mode. lay shows it is in EXT mode. (3) Push DOWN key once and display shows OUT

IWAKI Electromagnetic Metering Pump EH-E Type Instruction Manual

IWAKI Electromagnetic Metering Pump EH-E Type Instruction Manual IWAKI Electromagnetic Metering Pump Type Instruction Manual Read this manual before use of product Thank you for selecting the electromagnetic metering pump series. This instruction manual deals with Safety

More information

IWAKI Electromagnetic Metering Pump EHN-NAE Instruction Manual

IWAKI Electromagnetic Metering Pump EHN-NAE Instruction Manual IWAKI Electromagnetic Metering Pump EHN-NAE Instruction Manual Read this instruction manual before use of product Thank you for having selected IWAKI's EHN type electromagnetic metering pump. This instruction

More information

IWAKI Electromagnetic Metering Pump EH-F series (North America) Instruction Manual

IWAKI Electromagnetic Metering Pump EH-F series (North America) Instruction Manual IWAKI Electromagnetic Metering Pump EH-F series (North America) Instruction Manual Read this manual before use of product This is patent pending product.. Thank you for having selected IWAKI magnetic metering

More information

Iwaki Electromagnetic Metering Pump EWN-R (Standard)

Iwaki Electromagnetic Metering Pump EWN-R (Standard) Iwaki Electromagnetic Metering Pump EWN-R (Standard) Instruction manual Thank you for choosing our product. Please read through this instruction manual before use. This instruction manual describes important

More information

Iwaki Electromagnetic Metering Pump EWN-R (Standard)

Iwaki Electromagnetic Metering Pump EWN-R (Standard) Iwaki Electromagnetic Metering Pump EWN-R (Standard) Instruction manual Thank you for choosing our product. Please read through this instruction manual before use. This instruction manual describes important

More information

Iwaki Electromagnetic Metering Pump EHN-R (Standard)

Iwaki Electromagnetic Metering Pump EHN-R (Standard) Iwaki Electromagnetic Metering Pump EHN-R (Standard) Instruction manual Thank you for choosing our product. Please read through this instruction manual before use. This instruction manual describes important

More information

EH Series High Viscosity Electronic Metering Pumps Instruction Manual

EH Series High Viscosity Electronic Metering Pumps Instruction Manual EH Series High Viscosity Electronic Metering Pumps Instruction Manual Five Boynton Road Hopping Brook Park Holliston, MA 01746 USA TEL 508-429-1110 FAX 508-429-7433 WEBSITE: www.iwakiamerica.com Notice

More information

IWAKI Electromagnetic Metering Pump ES-B/C Type Instruction Manual. Read this manual before use of product

IWAKI Electromagnetic Metering Pump ES-B/C Type Instruction Manual. Read this manual before use of product IWAKI Electromagnetic Metering Pump ES-B/C Type Instruction Manual Read this manual before use of product Thank you for selecting the IWAKI's electromagnetic metering pump ES series. This instruction manual

More information

CAT-E Iwaki electromagnetic metering pumps

CAT-E Iwaki electromagnetic metering pumps CAT-E 001-0 Iwaki electromagnetic metering pumps High-tech combination of pump technology and electronics technology The EH series is the latest diaphragm-type electromagnetic metering pump, combining

More information

MDT Series Instruction Manual

MDT Series Instruction Manual IWAKI Magnetic Drive Turbine Pump MDT Series Instruction Manual Read this manual before use of product Thank you for having selected IWAKI s magnetic drive turbine pump MDT Series. This instruction manual

More information

IWAKI AMERICA EHC/EHE-FF Series Electronic Metering Pump Instruction Manual

IWAKI AMERICA EHC/EHE-FF Series Electronic Metering Pump Instruction Manual IWAKI AMERICA EHC/EHE-FF Series Electronic Metering Pump Instruction Manual INSTRUCTION MANUAL Notice 2004 Iwaki America Inc. Five Boynton Road, Holliston, MA 01746 USA tel (508) 429-1440 fax (508) 429-1386

More information

IX-C series. Instruction manual. Safety instructions Overview Installation Operation Maintenance Specification. Thank you for choosing our product.

IX-C series. Instruction manual. Safety instructions Overview Installation Operation Maintenance Specification. Thank you for choosing our product. IX-C series Instruction manual Thank you for choosing our product. Please read through this instruction manual before use. This instruction manual describes important precautions and instructions for the

More information

Digital Apex Locator. ipex OPERATION MANUAL OM-E0285E

Digital Apex Locator. ipex OPERATION MANUAL OM-E0285E Digital Apex Locator ipex OPERATION MANUAL 0197 OM-E0285E The EU directive 93/42/EEC was applied in the design and production of this medical device. Thank you for purchasing the ipex. This is apex locator.

More information

- click here for pricing and ordering

- click here for pricing and ordering www.pumpagents.com - click here for pricing and ordering No. 51-038 Mar. 01, 2006 MD-40R MD-40RX MD-40RZ(-5) Item Description Q'ty Material Part No. Part No. Part No. 1 Front Casing Unit 1 GFRPP+PTFE MD0053

More information

1100W PORTABLE GENERATOR

1100W PORTABLE GENERATOR 1100W PORTABLE GENERATOR MODEL NO: G1200 PART NO: 8010110 OPERATION & MAINTENANCE INSTRUCTIONS LS0312 INTRODUCTION Thank you for purchasing this CLARKE 1100W Portable Generator. Before attempting to use

More information

GRUNDFOS PRODUCT GUIDE DMH. Dosing pumps

GRUNDFOS PRODUCT GUIDE DMH. Dosing pumps GRUNDFOS PRODUCT GUIDE Dosing pumps Contents Features and benefits 3 Performance range 4 Pump selection options 36 Pumped liquids List of pumped liquids 39 Identification Type key 7 Functions Functional

More information

IWAKI Magnet Gear Pump MDG-M4 (built-in type) Instruction Manual

IWAKI Magnet Gear Pump MDG-M4 (built-in type) Instruction Manual IWAKI Magnet Gear Pump MDG-M4 (built-in type) Instruction Manual Read this manual before use of product This instruction manual includes descriptions of the correct handling of the pump, maintenance and

More information

IWAKI Magnet Gear Pump MDG-M4 Instruction Manual

IWAKI Magnet Gear Pump MDG-M4 Instruction Manual IWAKI Magnet Gear Pump MDG-M4 Instruction Manual Read this manual before use of product This instruction manual includes descriptions of the correct handling of the pump, maintenance and inspection procedures

More information

High Vacuum Diaphragm-Type Dry Vacuum Pump

High Vacuum Diaphragm-Type Dry Vacuum Pump No 腄 26300-2-02-3 High Vacuum Diaphragm-Type Dry Vacuum Pump DTC-120 DTC-120A, 120B, 120C (According to CE) Request to Users Please read this manual thoroughly to ensure safe and effective use of the equipment.

More information

BATCHING UNITS - PUMPS SERIES ACL - AXL - DPZ INSTRUCTIONS MANUAL WARNING!

BATCHING UNITS - PUMPS SERIES ACL - AXL - DPZ INSTRUCTIONS MANUAL WARNING! BATCHING UNITS - PUMPS SERIES ACL - AXL - DPZ DOSING PUMPS SERIE ACL - AXL - DPZ STORAGE TANKS SERIE SL WATER METER SERIE CD - CW INSTRUCTIONS MANUAL WARNING! The equipment must be used only for the utilization

More information

IWAKI Gas-Liquid Transfer Pump APN-05/-10/-20/-30/-60-W (built-in type) Instruction Manual. Read this manual before use of product

IWAKI Gas-Liquid Transfer Pump APN-05/-10/-20/-30/-60-W (built-in type) Instruction Manual. Read this manual before use of product IWAKI Gas-Liquid Transfer Pump APN-05/-10/-20/-30/-60-W (built-in type) Instruction Manual Read this manual before use of product Thank you for selecting the IWAKI APN series gas-liquid transfer pump.

More information

Precision-24 Manual & Specification

Precision-24 Manual & Specification Precision-24 Manual & Specification 1 Product Introduction... - 1-1.1 Product Overview... - 1-1.2 Technical Parameter...- 2-1.2.1 General Parameter...- 2-1.2.2 Performance Parameter... - 3-1.2.3 Installation

More information

IWAKI Gas-Liquid Transfer Pump APN-085-W Instruction Manual. Read this manual before use of product

IWAKI Gas-Liquid Transfer Pump APN-085-W Instruction Manual. Read this manual before use of product IWAKI Gas-Liquid Transfer Pump APN-085-W Instruction Manual Read this manual before use of product Thank you for selecting the IWAKI APN series gas-liquid transfer pump. This instruction manual deals with

More information

DOSING UNIT WITH TIME CONTROL INSTRUCTIONS MANUAL WARNING!

DOSING UNIT WITH TIME CONTROL INSTRUCTIONS MANUAL WARNING! DOSING UNIT WITH TIME CONTROL DOSING PUMP WITH TIME CONTROL SERIE DCK STORAGE TANKS SERIE SL INSTRUCTIONS MANUAL WARNING! The equipment must be used only for the utilization for which they have been designed,

More information

IWAKI METERING PUMPS AX

IWAKI METERING PUMPS AX IWAKI METERING PUMPS The highest reliability system metering Iwaki metering pumps series are compact hydraulic diaphragm pumps designed to meet the exacting requirements of modern advanced chemical processes.

More information

SYSTEM 4000 TRIMMER DBM-400T

SYSTEM 4000 TRIMMER DBM-400T SYSTEM 4000 TRIMMER Instruction Manual DUPLO CORPORATION INTRODUCTION Thank you for your purchase. To ensure correct usage, please read this instruction manual thoroughly, especially the section Safety

More information

IWAKI Gas-Liquid Transfer Pump APN-30/-60 GD3-W Instruction Manual. Read this manual before use of product

IWAKI Gas-Liquid Transfer Pump APN-30/-60 GD3-W Instruction Manual. Read this manual before use of product IWAKI Gas-Liquid Transfer Pump APN-30/-60 GD3-W Instruction Manual Read this manual before use of product Thank you for selecting an IWAKI APN-30/-60 GD3-W gasliquid transfer pump (BLDC motor). This instruction

More information

Diaphragm Valve Type 72

Diaphragm Valve Type 72 Serial No. H-V001-E-8 Diaphragm Valve Type 72 User s Manual Contents (1) Be sure to read the following warranty clauses of our product 1 (2) General operating instructions 2 (3) General instructions for

More information

Diaphragm Valves Type 15

Diaphragm Valves Type 15 Serial No. H-V031-E-8 Diaphragm Valves Type 15 User s Manual Contents (1) Be sure to read the following warranty clauses of our product 1 (2) General operating instructions 2 (3) General instructions for

More information

Instruction Manual. Digital Panel Meter Model 3126 CAUTION. Code Type of T/C Measuring Range Display Range Accuracy

Instruction Manual. Digital Panel Meter Model 3126 CAUTION. Code Type of T/C Measuring Range Display Range Accuracy Instruction Manual Digital Panel Meter Model 3126 I-01861 1. Preface Thank you for purchasing our digital panel meter 3126 series. Before use, read this manual carefully and thoroughly, and keep this manual

More information

High-speed detection even a little liquid leak

High-speed detection even a little liquid leak 737 Leak Sensor Related Information Amplifier Built-in EX-F70 SERIES SERIES Sensor selection guide...p.11~ / P.77~ General terms and conditions...p.1 General precautions...p.986~ PHOTO PHOTO Conforming

More information

ELECTRIC ACTUATOR. Unic Series ROTARY TYPE Unic Z, 05 Unic 10 Unic 20, 40 Unic 60, 100, 150, 200 OPERATION MANUAL. Koei Industry Co., Ltd.

ELECTRIC ACTUATOR. Unic Series ROTARY TYPE Unic Z, 05 Unic 10 Unic 20, 40 Unic 60, 100, 150, 200 OPERATION MANUAL. Koei Industry Co., Ltd. ELECTRIC ACTUATOR Unic Series ROTARY TYPE Unic Z, 05 Unic 10 Unic 20, 40 Unic 60, 100, 150, 200 OPERATION MANUAL Koei Industry Co., Ltd. FOR YOUR SAFETY In order for better and safety use of the product

More information

PDF-A Electromagnetic metering pumps. EHN series

PDF-A Electromagnetic metering pumps. EHN series PDF-A 0045-03 Electromagnetic metering pumps EHN series The latest electromagnetic metering pump equipped with digital controller & multi-voltage EHN Series is the latest electromagnet drive & diaphragm

More information

3-Way Ball Valve Type 23H

3-Way Ball Valve Type 23H Serial No. H-V062-E-4 contents 3-Way Ball Valve Type 23H User s Manual (1) Be sure to read following warranty clauses of our product 1 (2) General operating instructions 2 (3) General instruction for transportation,

More information

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC) User Guide Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC) version 04/2013 Content General Information 3 Warning 3 Scope of Supply 3 Overview 3 General safety details 4 Intended use 4

More information

IWAKI Air Pump APN-085-D3 Instruction Manual. Read this manual before use of product

IWAKI Air Pump APN-085-D3 Instruction Manual. Read this manual before use of product IWAKI Air Pump APN-085-D3 Instruction Manual Read this manual before use of product Thank you for selecting an IWAKI APN-085-D3 air pump. This instruction manual deals with "Safety Instructions", "Outline",

More information

ELECTRONIC CONTROL ACTUATOR

ELECTRONIC CONTROL ACTUATOR ELECTRONIC CONTROL ACTUATOR Nucom Series LINEAR TYPE Nucom L100 OPERATION MANUAL Koei Industry Co., Ltd. FOR YOUR SAFETY In order for better and safety use of the product for a long period, please observe

More information

TOWA SEIDEN INDUSTRIAL CO., LTD.

TOWA SEIDEN INDUSTRIAL CO., LTD. INSTRUCTION MANUAL SOUNDING LEVEL METER MODEL: TLX-120AP/200AP Meanings of indications for safety used in this Instruction Manual are as follows. WARNING: Indicates that improper handling assumes the risk

More information

Sediment strainer (Type Y)

Sediment strainer (Type Y) Installation,Operation and Maintenance Manual Serial No. H-V034-E-9 Sediment strainer (Type Y) Contents (1) Be sure to read the following warranty clauses of our product 1 User s Manual (2) General operating

More information

EHE Series Electronic Metering Pump Instruction Manual

EHE Series Electronic Metering Pump Instruction Manual EHE Series Electronic Metering Pump Instruction Manual Five Boynton Road Hopping Brook Park Holliston, MA 01746 USA TEL 508-429-1110 FAX 508-429-7433 Website: www.walchem.com Notice 2007 WALCHEM Corporation

More information

IWAKI Metering Pump LK-A, B, C Models Instruction Manual

IWAKI Metering Pump LK-A, B, C Models Instruction Manual IWAKI Metering Pump LK-A, B, C Models Instruction Manual Read this manual before use of product Thank you for selecting IWAKI s diaphragm pump LK. This pump is a diaphragm type metering pump of which the

More information

Swing Check Valve ASAHI AV VALVES. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1

Swing Check Valve ASAHI AV VALVES. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1 Serial No. H-V013-E-13 Swing Check Valve User s Manual Contents (1) Be sure to read the following warranty clauses of our product 1 (2) General operating instructions 2 (3) General instructions for transportation,

More information

DIGITAL RCD(ELCB) TESTER

DIGITAL RCD(ELCB) TESTER INSTRUCTION MANUAL DIGITAL RCD(ELCB) TESTER KEW 5410 R KYORITSU ELECTRICAL INSTRUMENTS WORKS, LTD. Contents 1. Safety Warnings.... 1 2. Procedure of removing Cover. 3 2-1 Method of removing the Cover.

More information

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE 2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE For Diaphragm Dosing Pumps FEM 1.02_.55 / FEM 1.09_.55 Controller board package, without pump: ID 160536 Operating and Installation Manual It is important to

More information

I. Safety precautions

I. Safety precautions . Safety precautions The items described in these instructions and on the inverter itself are very important so that you can use the inverter safely, prevent injury to yourself and other people around

More information

Thank you for selecting the GD submersible grinder pump.

Thank you for selecting the GD submersible grinder pump. GD INDEX Introduction..PAGE. 2 Nameplate format...page. 2 Prior to Operation...PAGE. 3 Installation....PAGE. 3 Electrical Wiring...PAGE. 4 Operation. PAGE. 5 Maintenance...PAGE. 5 Construction PAGE. 6

More information

INSTRUCTION MANUAL VISCOTESTER VT-05 / VT-06 PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

INSTRUCTION MANUAL VISCOTESTER VT-05 / VT-06 PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION INSTRUCTION MANUAL VISCOTESTER VT-05 / VT-06 PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION 3, Hagavish st. Israel 58817 Tel: 972 3 5595252, Fax: 972 3 5594529 mrc@mrclab.com MRC.4.17 Organization

More information

Instruction Manual LAMI CORPORATION INC.

Instruction Manual LAMI CORPORATION INC. Instruction Manual LAMI CORPORATION INC. Preface Thank you for purchasing our. This Instruction Manual (document) includes details for safe use of this product. Please read this document thoroughly before

More information

Battery Unit BHM60PC/BHM100PC Instruction Manual

Battery Unit BHM60PC/BHM100PC Instruction Manual Battery Unit BHM60PC/BHM100PC Instruction Manual For the use of UPS BH60PCW/BH100PCW This manual contains important information regarding the safe use of the BHM60PC/BHM100PC for the Backup Power Supply

More information

DIGITAL TORQUE GAUGE MODEL BTGE-G

DIGITAL TORQUE GAUGE MODEL BTGE-G DIGITAL TORQUE GAUGE MODEL BTGE-G OPERATING INSTRUCTION BTGE-G BTGE-G Model To use this product properly and safely, please read this manual carefully before use. If you have any question about the product

More information

Diaphragm Valve Type 14 Pneumatic Actuated Type AP. User s Manual. Contents H-A065-E. Serial No.

Diaphragm Valve Type 14 Pneumatic Actuated Type AP. User s Manual. Contents H-A065-E. Serial No. Serial No. H-A065-E Diaphragm Valve Type 14 Pneumatic Actuated Type AP User s Manual Contents (1) Be sure to read the following warranty clauses of our product 1 (2) General operating instructions 2 (3)

More information

User's Manual. MV100 Rechargeable Battery Model. Yokogawa Electric Corporation. IM MV100-41E 1st Edition

User's Manual. MV100 Rechargeable Battery Model. Yokogawa Electric Corporation. IM MV100-41E 1st Edition User's Manual MV100 Rechargeable Battery Model Yokogawa Electric Corporation 1st Edition Thank you for purchasing the MV100 Rechargeable Battery Model. This user s manual describes the rechargeable batteries.

More information

Lumitester PD-20 Control Kit

Lumitester PD-20 Control Kit 日本語による取扱説明は 17 ページからとなります Lumitester PD-20 Control Kit Operation manual Thank you for purchasing the Lumitester PD-20 Control Kit. To use this kit safely and correctly, read this operation manual carefully

More information

A B 0 0 C D E 6 7 G F F H 8 9 K M O O L N I J 1

A B 0 0 C D E 6 7 G F F H 8 9 K M O O L N I J 1 1 2 1 5 4 3 2 2 1 6 3 8 7 1 9 4 C A B 5 0 0 D E 6 G 7 F F H 8 K 9 M O O I J L N 1 GENERAL OPERATIONAL PRECAUTIONS 1. Keep work area clean. Cluttered areas and benches invite accidents. 2. Avoid dangerous

More information

Air Release Valve (PDCPD) Air Release Valve for Water (PDCPD + Epoxy Resin Coating) User s manual. Air Release Valve. Air Release Valve for Water

Air Release Valve (PDCPD) Air Release Valve for Water (PDCPD + Epoxy Resin Coating) User s manual. Air Release Valve. Air Release Valve for Water Serial No. H-V035-E-3 Air Release Valve (PDCPD) Air Release Valve for Water (PDCPD + Epoxy Resin Coating) Contents (page) User s manual () Be sure to read the following warranty clauses of our product

More information

Iwaki Electromagnetic Metering Pump EWN-W (For water quality control)

Iwaki Electromagnetic Metering Pump EWN-W (For water quality control) Iwaki Electromagnetic Metering Pump EWN-W (For water quality control) Instruction manual Thank you for choosing our product. Please read through this instruction manual before use. This instruction manual

More information

EHE Series Electronic Metering Pump Instruction Manual

EHE Series Electronic Metering Pump Instruction Manual W A L C H E M IWAKI America Inc. EHE Series Metering Pumps EHE Series Electronic Metering Pump Instruction Manual Five Boynton Road Hopping Brook Park Holliston, MA 01746 USA TEL: 508-429-1110 FAX: 508-429-7433

More information

Instruction Manual. Table of Contents. Powder Clutch, Brake MODEL ZKB-AN,BN Powder Clutch ZKB-YN,XN Powder Brake

Instruction Manual. Table of Contents. Powder Clutch, Brake MODEL ZKB-AN,BN Powder Clutch ZKB-YN,XN Powder Brake ZJ-267A Powder Clutch, Brake MODEL ZKB-AN,BN Powder Clutch ZKB-YN,XN Powder Brake Instruction Manual Table of Contents Cautions on Safety - - - - - - - - - - - - - - - - - 1 1. Cautions before use - -

More information

SERVO-TOP II ELECTRONIC ACTUATOR

SERVO-TOP II ELECTRONIC ACTUATOR INSTRUCTION MANUAL SERVO-TOP II ELECTRONIC ACTUATOR (linear type) PSN1 / PSN MODEL PSN1/PSN BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received

More information

Lumitester PD-30. Instruction Manual. Table of Contents

Lumitester PD-30. Instruction Manual. Table of Contents Table of Contents Lumitester PD-30 Instruction Manual Thank you very much for purchasing the Lumitester PD-30. All of this Instruction Manual must be read before operation of this product for safe and

More information

ISP-500B. Oil-free Scroll Vacuum Pump. Instruction Manual. View our inventory. Record of Pump Information. Serial Number: Purchase date:

ISP-500B. Oil-free Scroll Vacuum Pump. Instruction Manual. View our inventory. Record of Pump Information. Serial Number: Purchase date: ISP-500B Oil-free Scroll Vacuum Pump Instruction Manual View our inventory Serial Number: Record of Pump Information Purchase date: In Service date: Dealer information: IM-500B 1/3/07 Page 1 of 26 Important

More information

EW & EK Series Electronic Metering Pump Instruction Manual

EW & EK Series Electronic Metering Pump Instruction Manual EW & EK Series Electronic Metering Pump Instruction Manual Five Boynton Road Hopping Brook Park Holliston, MA 0176 USA TEL 508-29-1110 FAX 508-29-733 WEBSITE: www.walchem.com Notice 2007 WALCHEM Corporation

More information

Main material CFRETFE IWAKI SELF-PRIMING MAGNETIC DRIVE PUMPS SMX-F PATENT JAPAN / U.S.A. / EU / CHINA / TAIWAN

Main material CFRETFE IWAKI SELF-PRIMING MAGNETIC DRIVE PUMPS SMX-F PATENT JAPAN / U.S.A. / EU / CHINA / TAIWAN Main material CFRETFE IWAKI SELF-PRIMING MAGNETIC DRIVE PUMPS PATENT JAPAN / U.S.A. / EU / CHINA / TAIWAN Chemically resistant self-priming magnetic drive pumps which can tolerate abnormal operation The

More information

The Vario motor-driven pump series from ProMinent Adaptable to a wide range of applications VARIO METERING PUMP

The Vario motor-driven pump series from ProMinent Adaptable to a wide range of applications VARIO METERING PUMP The Vario motor-driven pump series from ProMinent Adaptable to a wide range of applications VARIO METERING PUMP ProMinent Modular design allows selection of the features you need Three diaphragm sizes

More information

IU0U automatic charger Read these instructions carefully before the installation and commissioning and keep them in a safe place. Pass it on to the buyer in case of the further sale of the system. Contents

More information

MULTI FUNCTIONAL COUNT CHECKER MODEL Poka Patrol CNA-4mk3

MULTI FUNCTIONAL COUNT CHECKER MODEL Poka Patrol CNA-4mk3 MULTI FUNCTIONAL COUNT CHECKER MODEL Poka Patrol CNA-4mk3 OPERATING INSTRUCTION Poka Patrol CNA-4mk3 Poka Patrol CNA-4mk3 To use this product properly and safely, please read this manual carefully before

More information

Diaphragm Valve Type 14 Pneumatic Actuated Type AV

Diaphragm Valve Type 14 Pneumatic Actuated Type AV Serial No. H-A015-E-7 Contents (1) Be sure to read the following warranty clauses of our product 1 Diaphragm Valve Type 14 Pneumatic Actuated Type AV (2) General operating instructions 2 (3) General instructions

More information

OPERATIONS MANUAL. Mini Centrifuge Model MCF Certified

OPERATIONS MANUAL. Mini Centrifuge Model MCF Certified OPERATIONS MANUAL Mini Centrifuge Model MCF-2360 Certified Contents 1. Safety 2 2. Introduction 7 3. Package Contents 7 4. Specifications 8 5. Features 8 6. Parts of the Mini Centrifuge 9 7. Installation

More information

Contents H-V034-E-12. Serial No. (page) (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

Contents H-V034-E-12. Serial No. (page) (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2 Serial No. H-V034-E-12 Sediment strainer (Type Y) Contents (page) (1) Be sure to read the following warranty clauses of our product 1 User s Manual (2) General operating instructions 2 (3) General instructions

More information

OPERATION MANUAL OM-K

OPERATION MANUAL OM-K UltraSonic Polisher OPERATION MANUAL OM-K0517 001 1. P 2 2. P 3 3. P 4 4. P 6 5. P 7 6. P 8 7. P 9 8. P 9 9. P10 10. P11 11. P11 12. P12 13. P13 CONTENTS 1. CAUTIONS FOR HANDLING AND OPERATION P16 2. SPECIFICATIONS

More information

Submersible Mixed Flow/Axial Flow Pump Model SAM Model SPM

Submersible Mixed Flow/Axial Flow Pump Model SAM Model SPM Instruction Manual Installation Manual Submersible Mixed Flow/Axial Flow Pump Model SAM Model SPM Thank you for your purchase of the Submersible Mixed Flow/Axial Flow Pump. Teral s Submersible Mixed Flow/Axial

More information

FD 120 Card Cutter MAINTENANCE MANUAL. MyBinding.com 5500 NE Moore Court Hillsboro, OR Toll Free: Local: /2011

FD 120 Card Cutter MAINTENANCE MANUAL. MyBinding.com 5500 NE Moore Court Hillsboro, OR Toll Free: Local: /2011 FD 120 Card Cutter 5/2011 MAINTENANCE MANUAL SAFETY PRECAUTIONS Always observe the cautions and warnings given below to prevent personal injury or property damage. The degree of danger and damage that

More information

Remote Control Engine Starter System Owner s Manual

Remote Control Engine Starter System Owner s Manual Remote Control Engine Starter System Owner s Manual Introduction 1. Introduction 2 2. Features of the System 3 3. Safety Precaution 4 4. Name of each part 6 5. Display 7 6. Operating the Transmitter 8

More information

Installation,Operation and Maintenance Manual H-V016-E-10. Serial No. 目次 ( ページ ) 1. Be sure to read the following warranty clauses of our product 1

Installation,Operation and Maintenance Manual H-V016-E-10. Serial No. 目次 ( ページ ) 1. Be sure to read the following warranty clauses of our product 1 Serial No. H-V016-E-10 Gauge Valve 目次 ( ページ ) 1. Be sure to read the following warranty clauses of our product 1 2. General operating instructions 2 User s Manual 3. General instructions for transportation,

More information

EHB/C & EZ Series Electronic Metering Pump Instruction Manual

EHB/C & EZ Series Electronic Metering Pump Instruction Manual EHB/C & EZ Series Electronic Metering Pump Instruction Manual Five Boynton Road Hopping Brook Park Holliston, MA 01746 USA TEL 508-429-1110 FAX 508-429-7433 WEBSITE: www.walchem.com Notice 2002 WALCHEM

More information

GD series Submersible Grinder Pump

GD series Submersible Grinder Pump GD series Submersible Grinder Pump 60HZ STAIRS INDUSTRIAL CO., LTD. GD series-submersible Grinder Pump Model code GD - 15-30 - M A A = AUTO M = Single Phase T = Three Phase Connection dimensions Output

More information

PURE SINE WAVE DC TO AC POWER INVERTER

PURE SINE WAVE DC TO AC POWER INVERTER PURE SINE WAVE DC TO AC POWER INVERTER 60S-12A / 60S-24A 60S-12E / 60S-24E 100S-12A / 100S-24A 100S-12E / 100S-24E 150S-12A / 150S-24A 150S-12E / 150S-24E Instruction manual SINE WAVE INVERTER Please read

More information

Construction diagram Semiconductor transducer Silicone oil. Stainless steel SUS316 pressure port Hastelloy C diaphragm.

Construction diagram Semiconductor transducer Silicone oil. Stainless steel SUS316 pressure port Hastelloy C diaphragm. SERIES LED Display Anti-corrosive Digital ure Sensor DP3 ure Measurement of Corrosive Gases and Liquids Possible! Marked Conforming to EMC Directive Superior Anti-corrosive Hastelloy C Diaphragm and Stainless

More information

GATE VALVES. Type P (Standard: Plug) Type S (Soft Seal) Contents. (1) Be sure to read the following warranty clauses of our product 1

GATE VALVES. Type P (Standard: Plug) Type S (Soft Seal) Contents. (1) Be sure to read the following warranty clauses of our product 1 Serial No. H-V011-E-12 GATE VALVES Type P (Standard: Plug) Type S (Soft Seal) Contents (1) Be sure to read the following warranty clauses of our product 1 User s Manual (2) General operating instructions

More information

EX-F70 SERIES EX-F60 SERIES

EX-F70 SERIES EX-F60 SERIES 85 Leak Sensor Related Information Amplifier Built-in EX-F70 SERIES SERIES General terms and conditions... F-17 General precautions... P.105 Sensor selection guide... P.81~ Korea s S-mark... P.110 PHOTO

More information

ELECTRONIC CONTROL ACTUATOR

ELECTRONIC CONTROL ACTUATOR ELECTRONIC CONTROL ACTUATOR Nucom Series LINEAR TYPE Nucom L25 Nucom L50 OPERATION MANUAL Koei Industry Co., Ltd. FOR YOUR SAFETY In order for better and safety use of the product for a long period, please

More information

Technical Information Manual

Technical Information Manual Technical Information Manual Revision n. 4 18 June 2008 MOD. A3000NF 3-PHASE NOTCH FILTER MANUAL REV. 4 NPO: 00120/04:3000N.MUTx/04 CAEN will repair or replace any product within the guarantee period if

More information

3M TM Filter Housing 1BS-T/1BS-TW Series

3M TM Filter Housing 1BS-T/1BS-TW Series READ FIRST 3M TM Filter Housing 1BS-T/1BS-TW Series Operation Manual CONTENTS Introduction 1 For Your Safety 1,2 Attention to galling or seizure of treaded portions 2 Specifications 3 Part names 4 Installation

More information

1200W INVERTER GENERATOR

1200W INVERTER GENERATOR 1200W INVERTER GENERATOR MODEL NO: IG1200 PART NO: 8877070 OPERATION & MAINTENANCE INSTRUCTIONS LS0117 INTRODUCTION Thank you for purchasing this CLARKE 1200W Inverter Generator. Before attempting to use

More information

IWAKI PNEUMATIC-DRIVEN BELLOWS PUMP CFD-8T-B TYPE Instruction Manual. Read this manual before use of product

IWAKI PNEUMATIC-DRIVEN BELLOWS PUMP CFD-8T-B TYPE Instruction Manual. Read this manual before use of product IWAKI PNEUMATIC-DRIVEN BELLOWS PUMP CFD-8T-B TYPE Instruction Manual Read this manual before use of product Thank you for having purchased the Iwaki Bellows Pump Model: CFD-8T-B. This pump is designed

More information

Instruction Manual. Series E7 Metering Pumps. For file reference, please record the following data:

Instruction Manual. Series E7 Metering Pumps. For file reference, please record the following data: Instruction Manual Series E7 Metering Pumps For file reference, please record the following data: Model No: Serial No: Installation Date: Installation Location: When ordering replacement parts for your

More information

Differential Pressure Transmitter

Differential Pressure Transmitter Specifications/Instructions Differential Pressure Transmitter General Model PY9000D is a differential pressure transmitter that uses a ceramic cantilever sensor. Deflection of the ceramic cantilever caused

More information

1580R User s Manual. Multi-Purpose, High Speed Centrifuge. Gyrozen Co., Ltd.

1580R User s Manual. Multi-Purpose, High Speed Centrifuge. Gyrozen Co., Ltd. Multi-Purpose, High Speed Centrifuge 1580R User s Manual Gyrozen Co., Ltd. B Station, 30-12 Gyeryong-ro 141-gil, Yuseoung-gu, Daejeon 305-301, Korea Tel: +82-42-719-8200 Fax: +82-42-826-9848 www.gyrozen.com

More information

BEFORE USING THE PRODUCT

BEFORE USING THE PRODUCT HL-17015-5 BEFORE USING THE PRODUCT Thank you for purchasing an Oriental Motor product. Please read this BEFORE USING THE PRODUCT and the separate manual entitled OPERATING MANUAL thoroughly to ensure

More information

IWAKI Air Pump BAN-0510/-0505 Instruction Manual. Read this manual before use of product

IWAKI Air Pump BAN-0510/-0505 Instruction Manual. Read this manual before use of product IWAKI Air Pump BAN-0510/-0505 Instruction Manual Read this manual before use of product Thank you for selecting an IWAKI BAN-0510/-0505 air pump. This instruction manual deals with "Safety Instructions",

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS BATTERY CHARGER IR-200BC TABLE OF CONTENTS 1. SAFETY PRECAUTIONS... 2 2. GENERAL DESCRIPTION... 3 3. HANDLING PRECAUTIONS... 3 4. NOMENCLATURE AND FUNCTIONS... 4 5. CHARGING... 5

More information

Air Operated Double Diaphragm Pump. M-Pump ½ Metallic Non Metallic Pump INSTALLATION, OPERATION & MAINTENANCE MANUAL

Air Operated Double Diaphragm Pump. M-Pump ½ Metallic Non Metallic Pump INSTALLATION, OPERATION & MAINTENANCE MANUAL Air Operated Double Diaphragm Pump M-Pump ½ Metallic Non Metallic Pump INSTALLATION, OPERATION & MAINTENANCE MANUAL 0.5 I.O.M rev 05. 12/2015 INDEX Title Section Introduction.1 Safety.2 Warranty, General

More information

ProMinent Sigma/ 3 Motor Diaphragm Metering Pumps

ProMinent Sigma/ 3 Motor Diaphragm Metering Pumps Overview: Sigma/ 3 (S3Cb) The Sigma/3 motor diaphragm are produced with a high-strength metal inner housing for parts subject to load as well as an additional plastic housing to protect against corrosion.

More information

CONTENTS. 3 MAINTENANCE 3.1 Service and Maintenance Maintenance and cleaning Glass breakage Disinfection

CONTENTS. 3 MAINTENANCE 3.1 Service and Maintenance Maintenance and cleaning Glass breakage Disinfection 1 PRODUCT DESCRIPTION 1.1 Usage in accordance with safety standards 1.1.1 General Information 1.1.1.1 Hazards and precautions 1.1.1.2 Brief description 1.1.1.3 Safety standards 1.1.1.4 Included items 1.1.1.5

More information

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions Series ISE70/75/75H NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. For General Fluids For Air 2-Color Display (Green/Red) Selectable from four patterns ON Red Green Red Green

More information

Assembly and Maintenance Manual Type ASNU

Assembly and Maintenance Manual Type ASNU Assembly and Maintenance Manual Type ASNU Hatschekstr.36 69126 Heidelberg Germany Tel +49(0)6221 30470 Fax +49(0)6221 304731 info@stieber.de www.stieber.de Date of issue: 30.05.2018 GB Revision: 0 U:\EngUsers\!ProduktDoku\1AAA_Einbauerklaerung_Wartungsanleitung_Konformitaetserklaerung\1AAA_Wartungsanleitungen\Orginal_Worddatei\_ASNU.docx

More information

USE and MAINTENANCE INSTRUCTION MANUAL AZ3 HTE2 AZ3 HTE2 HVLP GRAVITY. SPRAY GUN Series. en it fr es pt de se

USE and MAINTENANCE INSTRUCTION MANUAL AZ3 HTE2 AZ3 HTE2 HVLP GRAVITY. SPRAY GUN Series. en it fr es pt de se USE and MAINTENANCE INSTRUCTION MANUAL AZ3 HTE2 AZ3 HTE2 HVLP GRAVITY SPRAY GUN Series en it fr es pt de se TECHNICAL DATA Technical AZ3 HTE2 AZ3 HTE2 HVLP 1.0 80 180 1.3 10-15HTE 140 200 240 1.5 2.0 160

More information

GENERATOR MODEL NO: FG3005 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0413

GENERATOR MODEL NO: FG3005 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0413 GENERATOR MODEL NO: FG3005 PART NO: 8857707 OPERATION & MAINTENANCE INSTRUCTIONS LS0413 INTRODUCTION Thank you for purchasing this CLARKE Generator. Before attempting to use this product, please read this

More information

DIGITAL TEMPERATURE CONTROL

DIGITAL TEMPERATURE CONTROL Fridge / Freezer / Warmer with DIGITAL TEMPERATURE CONTROL MODEL MHD13F-DM SPECIFICATION DESIGNATION OF PARTS MODEL CAPACITY OUTER DIMENSIONS INPUT RATING ( or FREEZER) (WARMER) REFRIGERANT WEIGHT MHD13F-DM

More information

EW-F & EK Series Electronic Metering Pump Instruction Manual

EW-F & EK Series Electronic Metering Pump Instruction Manual W A L C H E M IWAKI America Inc. EW-F & EK Series Metering Pumps EW-F & EK Series Electronic Metering Pump Instruction Manual Five Boynton Road Hopping Brook Park Holliston, MA 0176 USA TEL: 508-29-1110

More information