CWW Circular duct heaters for hot water
|
|
- Prudence Caldwell
- 5 years ago
- Views:
Transcription
1 Circular duct heaters for hot water
2 Circular duct heaters for hot water The with circular duct connections uses hot water as the energy carrier and is used for heating the ventilation air in a ventilation system. The can also be used for heating individual rooms or zones. For controlling the room or supply air temperature, the duct heater is supplemented with regulators, sensors, actuators, valves and anti-freeze protection. 15 standard sizes Circular duct connection with rubber seal Casing of Aluzinc-coated sheet steel, AZ 185 Openable cover for inspection and cleaning Hot water coil with 2 or 3 tube rows tightness class C to EN Design The casing is made of Aluzinc-coated sheet steel, AZ 185. The coil has copper tubes and tube connections, and aluminium fins. An openable cover simplifies inspection and cleaning. The duct connections are provided with rubber seals. The duct heater conforms to air tightness class C to EN Operating data Max. operating temperature: +150 C Max. operating pressure: 1,0 MPa (10 bar) The coils are pressure tested and tested for leakage. Capacity Examples of capacity for each size are given on pages 4 to 11. You can also do your own calculations using our webbased VEAB Select calculation program ( or get in touch with our sales technicians for assistance. tightness class C The duct heater conforms to air tightness class C, which ensures that the heated air will reach its destination and will not leak out of the ventilation system which saves energy and money. Installation The can be installed in a horizontal or vertical duct, with the air in either direction. Control See pages 12 to 15 for a list of regulators, sensors, valves and actuators. Page 2 Chap. 4
3 F H CIRCULAR DUCT HEATERS FOR HOT WATER Product range overview and dimensions Type D mm B mm H mm dy mm F mm G mm K mm L mm Coil inside volume l Weight kg dy D H+8 B G K G L Project design/ordering Descriptive text for VEAB type duct heater with casing made of Aluzinc-coated sheet steel, AZ 185, coil with copper tubes and tube connections, and with aluminium fins. The duct heater conforms to air tightness class C. The heater is controlled by an external regulator, sensors, valves and actuators, which must be ordered separately. Type designation (example) Size designation Number of tube rows Fin pitch, mm Specify the following for project ordering: 1. rate: - m³/h 2. Inlet air temperature: - C 3. or required output: - C or -kw 4. Duct size: - mm 5. Inlet water : - C 6. Outlet water or water : - C or - l/sec 7. Anti-freeze agent - type / % Chap. 4 Page 3
4 Capacity of ,5 in/out 80 C/60 C in/out 60 C/40 C in/out 55 C/45 C Inlet air Capacity of ,5 in/out 80 C/60 C in/out 60 C/40 C in/out 55 C/45 C Inlet air Page 4 Chap. 4
5 Capacity of ,5 in/out 80 C/60 C in/out 60 C/40 C in/out 55 C/45 C Inlet air Capacity of ,5 in/out 80 C/60 C in/out 60 C/40 C in/out 55 C/45 C Inlet air Chap. 4 Page 5
6 Capacity of ,5 in/out 80 C/60 C in/out 60 C/40 C in/out 55 C/45 C Inlet air Capacity of ,5 in/out 80 C/60 C in/out 60 C/40 C in/out 55 C/45 C Inlet air Page 6 Chap. 4
7 Capacity of ,5 in/out 80 C/60 C in/out 60 C/40 C in/out 55 C/45 C Inlet air Capacity of ,5 in/out 80 C/60 C in/out 60 C/40 C in/out 55 C/45 C Inlet air Chap. 4 Page 7
8 Capacity of ,5 in/out 80 C/60 C in/out 60 C/40 C in/out 55 C/45 C Inlet air Capacity of ,5 in/out 80 C/60 C in/out 60 C/40 C in/out 55 C/45 C Inlet air Page 8 Chap. 4
9 Capacity of ,5 in/out 80 C/60 C in/out 60 C/40 C in/out 55 C/45 C Inlet air ,0 11,3 0,14 7,2 24,1 8,4 0,10 4,2 25,6 8,7 0,21 16, ,5 41,3 10,1 0,12 5,8 27,2 7,2 0,09 3,2 28,7 7,5 0,18 12, ,4 9,0 0,11 4,6 30,1 6,1 0,07 2,3 31,7 6,4 0,16 9, ,5 47,4 7,9 0,10 3,6 32,7 5,0 0,06 1,6 34,6 5,3 0,13 6, ,2 6,8 0,08 2,7 35,1 3,9 0,05 1,0 37,3 4,3 0,10 4, ,1 16,2 0,20 14,3 16,8 12,0 0,15 8,2 18,2 12,5 0,30 33, ,5 32,2 14,5 0,18 11,6 20,7 10,3 0,13 6,2 22,1 10,8 0,26 25, ,2 12,9 0,16 9,2 24,4 8,7 0,11 4,5 26,0 9,2 0,22 18, ,5 40,0 11,3 0,14 7,1 28,0 7,1 0,09 3,1 29,7 7,7 0,19 13, ,7 9,7 0,12 5,4 31,4 5,5 0,07 1,9 33,3 6,2 0,15 8, ,3 20,1 0,25 21,4 12,4 14,8 0,18 12,2 13,8 15,5 0,38 50, ,5 26,9 18,0 0,22 17,4 16,8 12,7 0,15 9,2 18,2 13,5 0,33 38, ,3 15,9 0,20 13,8 21,1 10,7 0,13 6,7 22,5 11,5 0,28 28, ,5 35,6 14,0 0,17 10,7 25,2 8,8 0,11 4,6 26,7 9,5 0,23 19, ,8 12,0 0,15 8,0 29,2 6,9 0,08 2,9 30,8 7,7 0,19 13,1 Capacity of ,5 in/out 80 C/60 C in/out 60 C/40 C in/out 55 C/45 C Inlet air Chap. 4 Page 9
10 Capacity of ,5 in/out 80 C/60 C in/out 60 C/40 C in/out 55 C/45 C Inlet air Capacity of ,5 in/out 80 C/60 C in/out 60 C/40 C in/out 55 C/45 C Inlet air Page 10 Chap. 4
11 Capacity of ,5 in/out 80 C/60 C in/out 60 C/40 C in/out 55 C/45 C Inlet air ,8 26,6 0,33 16,9 21,8 19,7 0,24 9,5 23,2 20,4 0,50 39, ,5 38,4 23,8 0,29 13,6 25,1 17,0 0,21 7,2 26,6 17,7 0,43 29, ,8 21,1 0,26 10,8 28,3 14,3 0,17 5,2 29,9 15,1 0,37 21, ,5 45,0 18,5 0,23 8,3 31,3 11,7 0,14 3,5 33,0 12,5 0,30 15, ,1 15,9 0,20 6,2 34,0 9,1 0,11 2,2 36,0 10,1 0,24 10, ,3 37,7 0,46 33,0 14,6 27,8 0,34 18,5 16,0 29,0 0,70 77, ,5 29,6 33,7 0,41 26,7 18,8 23,9 0,29 13,9 20,2 25,2 0,61 58, ,8 29,9 0,37 21,1 22,8 20,2 0,25 10,0 24,3 21,5 0,52 43, ,5 37,9 26,2 0,32 16,3 26,7 16,5 0,20 6,8 28,2 17,9 0,43 30, ,8 22,5 0,28 12,2 30,4 12,9 0,16 4,3 32,1 14,3 0,35 19, ,7 46,4 0,57 49,4 10,5 34,1 0,41 27,5 11,8 35,8 0,87 116, ,5 24,5 41,5 0,51 39,9 15,1 29,4 0,36 20,7 16,4 31,1 0,75 88, ,1 36,8 0,45 31,5 19,6 24,8 0,30 14,9 21,0 26,5 0,64 64, ,5 33,7 32,2 0,40 24,3 24,0 20,3 0,25 10,1 25,4 22,1 0,54 45, ,1 27,7 0,34 18,2 28,2 15,9 0,19 6,3 29,8 17,7 0,43 29,6 Chap. 4 Page 11
12 REGULATORS AND ACCESSORIES Regulators AQUA24TF RC RC-DO OPTIGO OP10 AQUA Complete regulator with built-in room sensor. Floating control for controlling three-position actuators. Cascade connection with minimum limit for room temperature control. Can be equipped with external room and/or duct sensor and external setpoint adjustment. Temperature range 0-30 C, depending on the sensor employed. AQUA24TF 24V supply. The regulator has a built-in controlling antifreeze protection with two alarm relays and automatic control for heating during stoppage. REGIO MINI Complete regulator with built-in room sensor. Can be equipped with external room and/or duct sensors. Has two control outputs, e.g. for heating and cooling in sequence. RC 24V supply. 0 10V output control signal. DIP switches are used for basic C setpoint setting. The basic setting can be adjusted by ±3 C by means of the setpoint knob. RC-DO 24V supply. 0 10V output control signal. The RC-DO has a back-lit display and a temperature range of 0-50 C. OPTIGO Regulator with display. One knob for all settings. For mounting on DIN rail. Operates with PT1000 sensor in the range of -20 C to + 40 C. Started/stopped with run signal from the fan. OP5 24V supply V control signal output. Operates with one sensor (room or duct sensor). Can be reset for heating or cooling control. OP10 24V supply. Can be reset for 0 10V control signal output or 3-point control. Two control outputs, e.g. for heating and cooling in sequence. Input for two sensors and anti-freeze sensor. Supply air temperature control or room temperature control with cascade-controlled supply air. Anti-freeze control with heating during stoppage., e.g. for starting/ stopping of fans via 230V~, 5A relay. Programmable oneweek timer for controlling of both fan and heating/cooling. Terminal for external timer that extends the operating time. Can be equipped with external setpoint adjuster. OP Same functions as the OP10, but with 230V~ supply. Page 12 Chap. 4
13 REGULATORS AND ACCESSORIES Accessories for AQUA Accessories for OPTIGO and REGIO Product Range Design Duct sensor TG-K C protection IP20 Product Range Design Duct sensor TG-K3/PT C protection IP20 Room sensor TG-R430 with setpoint adjustment 0-30 C protection IP30 Room sensor TG-R5/PT C protection IP30 Room sensor TG-R C protection IP30 Room sensor TG-UH/PT C protection IP65 Room sensor TG-R C protection IP54 Direct-contact sensor TG-A C protection IP65 Delivered with clamp. Direct-contact sensor TG-A130 Delivered with clamp C protection IP65 Trafo 60 Totally enclosed transformer for wall mounting. Built-in twopole fuse on secondary side. Primary voltage 230V~ Secondary voltage 24V~ Max. rating 60 VA protection IP44 Trafo 60 Totally enclosed transformer for wall mounting. Built-in twopole fuse on secondary side. Primary voltage 230V~ Secondary voltage 24V~ Max. rating 60 VA protection IP44 Chap. 4 Page 13
14 ACTUATORS AND VALVES Actuators and valves for Kv (110 C max) Description 3-position actuator for ZTV/ZTR valves, degree of protection IP44 Actuator for V signal for ZTV/ZTR valves, degree of protection IP44 Description Kv Type 2-way ½ valve 0.25 ZTV way ½ valve 0.4 ZTV way ½ valve 0.6 ZTV way ½ valve 1.0 ZTV way ½ valve 1.6 ZTV way ¾ valve 2.0 ZTV way ¾ valve 2.5 ZTV way ¾ valve 4.0 ZTV Type RVAZ4-24 RVAZ4-24A Actuator RVAZ4-24 Valve ZTV 2-way ¾ valve 6.0 ZTV way 1 valve 8.0 ZTVB way ½ valve 0.25 ZTR way ½ valve 0.4 ZTR way ½ valve 0.6 ZTR way ½ valve 1.0 ZTR way ½ valve 1.6 ZTR way ¾ valve 2.0 ZTR way ¾ valve 2.5 ZTR way ¾ valve 4.0 ZTR way ¾ valve 6.0 ZTR way 1 valve 8.0 ZTRB25-8 Actuators and valves for Kv (max 185 C) Description 3-position actuator for MTVS/MTRS valves, degree of protection IP54 Type RVAN5-24 Valve ZTR Actuator RVAN5-24 Actuator for V signal for MTVS/MTRS valves, degree of protection IP54 Description Kv Type 2-way ½ valve 1.0 MTVS RVAN5-24A 2-way ½ valve 1.6 MTVS way ½ valve 2.1 MTVS way ½ valve 2.7 MTVS Valve MTVS 2-way ¾ valve 4.2 MTVS way ¾ valve 5.6 MTVS way 1 valve 10.0 MTVS way 1 ¼ valve 16.0 MTVS way ½ valve 0.63 MTRS way ½ valve 1.0 MTRS way ½ valve 1.6 MTRS Valve MTRS 3-way ½ valve 2.1 MTRS way ½ valve 2.7 MTRS way ¾ valve 4.2 MTRS way ¾ valve 5.6 MTRS way 1 valve 10.0 MTRS way 1 ¼ valve 16.0 MTRS32-16 Page 14 Chap. 4
15 ACTUATORS AND VALVES Guide for selection of valves and actuators for heaters 110 C max. water temperature Actuator RVAZ4-24 (3-position) or RVAZ4-24A (0 10V) can be used for all ZTV/ZTR valves. 185 C max. water temperature Actuator RVAN5-24 (3-position) or RVAN5-24A (0 10V) can be used for all MTVS/MTRS valves. Type of Valve type Kv Type of Valve type Kv , , , , , , , , , , , , , , ,5 2-way ZTV way ZTR way ZTV way ZTR way ZTV way ZTR way ZTV way ZTR way ZTV way ZTR way ZTV way ZTR way ZTV way ZTR way ZTV way ZTR way ZTV way ZTR way ZTV way ZTR way ZTV way ZTR way ZTV way ZTR way ZTV way ZTR way ZTV way ZTR way ZTV way ZTR ,5 2-way MTVS ,5 2-way MTVS ,5 2-way MTVS ,5 2-way MTVS ,5 2-way MTVS ,5 2-way MTVS ,5 2-way MTVS ,5 2-way MTVS ,5 2-way MTVS ,5 2-way MTVS way MTRS ,5 2-way MTVS way MTRS ,5 2-way MTVS way MTRS ,5 2-way MTVS way MTRS ,5 2-way MTVS way MTRS ,5 2-way MTVS way MTRS Pressure s across valves Pressure Tryckfall mvp kpa kvs 0,63 1,0 1,6 2,1 2,7 4,2 5, ,8 0,6 0,5 0,4 0,3 0, ,1 Flow Flöde 1 l/s 0,01 0,02 0,03 0,05 0,08 0,1 0,2 0,3 0,4 0,5 0, m /h 0,05 0,08 0,1 0,2 0,3 0,4 0,5 0, Chap. 4 Page 15
16 VEAB Heat Tech AB Phone: +46(0) Fax: +46(0) Sweden
CWK Circular duct coolers for cooled water
Circular duct coolers for cooled water Circular duct coolers for cooled water The with circular duct connection uses chilled water as the energy carrier and is used for cooling the ventilation air in a
More informationPGV Rectangular duct heaters for hot water
Rectangular duct heaters for hot water Rectangular duct heaters for hot water The with rectangular duct connection uses hot water as the energy carrier and is used for heating the ventilation air in a
More informationPGK Rectangular duct coolers for cooled water
Rectangular duct coolers for cooled water Rectangular duct coolers for cooled water The with rectangular duct connection uses chilled water as the energy carrier and is used for cooling the ventilation
More informationCWK Circular duct coolers for cooled water
Circular duct coolers for cooled water Circular duct coolers for cooled water duct coolers are designed for using cooled water as the cooling medium and are used for cooling the ventilation air in ventilation
More informationPrice list - September Prices in EURO. For the latest information about our products, visit
GB Price list - September 2012 Prices in EURO For the latest information about our products, visit www.veab.com Content Duct heaters - electric Modell Page 3 Circular CV -MQU / -MQEM / -MQXL Page 4 Circular
More informationZTV/ZTR. Externally threaded 2- and 3-way zone valves. Function. No leakage in closed position
Revision 12 2015 Externally threaded 2- and 3-way zone valves Valves used for control of hot and cold water in climate, heating and ventilation systems. They can also control glycol-mixed water in for
More informationRC-DO. Room controllers with display and manual forced ventilation function
revision 10 2017 RC-DO Room controllers with display and manual forced ventilation function RC-DO is a room controller from the Regio Mini series intended to control heating and cooling in a single zone.
More informationAccessories. Series REC
Accessories Series REC 5-7-9 ACCESSORIES REC Series RBA BAF RBE CV3 PC3 SRE PSD CSA GIU TPA O. REC 5 REC 5-6 - 5BT11 5BT6 1CO71 1CO73 1SE96 5PR 1KR6 5SU137 5TE1 REC 5-12 5BT12 5BT122 5BT121 1CO71 1CO73
More informationV200 V200. Control on water, proportional integral. Simplified Master / Slave operation GENERAL DESCRIPTION
Master Slave 1 Slave (n + 1) Master Slave 1 Slave (n + 1) Simplified Master / Slave operation GENERAL is a CIAT electronic control system designed to control non-independent air conditioning terminal units
More informationHeat exchanger. Type WL. For the reheating of airflows in circular ducting PD WL 1. 03/2017 DE/en
X X testregistrierung Heat exchanger Type For the reheating of airflows in circular ducting Circular hot water heat exchanger for the reheating of airflows, suitable for VAV terminal units Type TVR and
More informationVAV TERMINAL BOXES TYPE: BA BT
Installation dimensions View inlet side View outlet side C G F E ø D A 65 ø8 B 25 Side view Top view 40 150 150 L1 Application ø D 150 Size operating range q (m 3 /h) Min. Max. Nom. 125 90 150-440 500
More informationChiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75.
Chiller AQL/ to 75 Air Cooled Water Chillers Only and Heat Pump Engineering Data Manual.0 to 75.8 kw 39.9 to 77.2 kw Outstanding Strength Points R410A Refrigerant. New simpler refrigerant circuit layout.
More informationPH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C
PH120 R410a Refrigerant Rooftop Packaged INDOOR COIL ENTERING AIR TEMP 0 c DB WB 21 23 25 27 29 31 PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C 30 35 40 45 Cap Cap Cap Cap 17 115.3 70.7 11.5
More informationPGDX Rectangular duct coolers with DX coil
Rectangular duct coolers with DX coil 10,0 Rectangular duct coolers with DX COIL Rectangular duct coolers with DX coil are used for central coolg of the ventilation air ventilation systems. The is also
More informationHRS. Very high efficiency heat recovery units. from 300 to m³/h >90 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR
4 Lmf Clima 6 FERRARO GROUP HRS Very high efficiency heat recovery units WITH HIGH EFFICIENCY HEAT RECOUPERATOR from 3 to 4. m³/h Air-handling unit designed and manufactured for nonresidential applications,
More informationHRH. High efficiency heat recovery units. from 300 to m³/h >70 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR
4 Lmf Clima 6 HRH High efficiency heat recovery units WITH HIGH EFFICIENCY HEAT RECOUPERATOR from 3 to 4.3 m³/h The HRH units have been designed for non-residential applications for which a forced and
More informationCAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1
X X testregistrierung CAV controllers Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical
More information^áêëçåâ=ìåáí=åççäéêë=qvoj^ pí~åç~êç=åççäéêë=ïáíü=pí~áåäéëë=píééä=íìäáåö
^áêëçåâ=ìåáí=åççäéêë= pí~åç~êç=åççäéêë=ïáíü=pí~áåäéëë=píééä=íìäáåö O `çåíéåíë= page Model indication................................ 2 Eurovent...................................... 2 Capacities.....................................
More informationCGA CXA VGA VXA CG-PRC006-E4
Cooling Only or Reversible Air Cooled Water Chiller CGA 075-100-120-150-200-240 CXA 075-100-120-150-200-240 VGA 075-100-120-150-200-240 VXA 075-100-120-150-200-240 Designed with your needs in mind TRANE
More informationAdvantage-D. Operating Instructions and Maintenance Manual. Central Vacuum Systems (Expandable/Modular Models) (Ver.
Advantage-D Series 3 Central Vacuum Systems (Expandable/Modular Models) (Ver. 8/05) Operating Instructions and Maintenance Manual DESCRIPTION The Becker Advantage-D and Advantage-L central vacuum systems
More informationfåçìëíêá~ä=~áê=åççäéêë=qvo pí~åç~êç=åççäéêë=ïáíü=ëí~áåäéëë=ëíééä=íìäáåö
fåçìëíêá~ä=~áê=åççäéêë= pí~åç~êç=åççäéêë=ïáíü=ëí~áåäéëë=ëíééä=íìäáåö O `çåíéåíë= page Model indication..................................2 Eurovent.......................................2 Capacities......................................2
More informationVariable Air Volume Dampers
OVAV 2000 SERIES OPTIMA VAV DAMPERS Overview OPTIMA make Variable Air Volume (OVAV) box is a part of an Air Conditioning system. It is located inside the duct work. VAV Dampers are designed to control
More informationTWA S/K/P. Incorporating. R410A Air cooled water chillers with axial fans and scroll compressors from 189 kw to 1007 kw
TWA 212-1102 S/K/P Incorporating R410A Air cooled water chillers with axial fans and scroll compressors from 189 kw to 1007 kw The complete solution to all your cooling needs TWA 212-1102 S/K/P Index
More informationAir-Cooled Liquid Chiller with integrated hydraulic module
Air-Cooled Liquid Chiller with integrated hydraulic module Cooling only: CGAN 200-250 - 300-400 - 450-490 - 500-600 - 700-800 - 900-925 Reversible: CXAN 200-250 - 300-400 - 450-490 - 500-600 - 700-800
More informationPerformance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW
R410a Refrigerant SHS1 Split Ducted Model INDOOR COIL ENTERING AIR TEMP DB WB 21 23 2 27 29 31 Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE 30 3 40 4 17 14.0 9.1 9.8 13.2 8.8 9.0 12. 8. 12.9
More informationCompresseur scroll. Refrigerant R410A SYSAQUAC. Air Cooled Condensing Units Models 25 to to 136.0kW
Compresseur scroll Refrigerant R410A SYSAQUAC Air Cooled Condensing Units Models 25 to 125 32.0 to 136.0kW SYSAQUA Condensation 1 Key Points R410A refrigerant, Units are optimized for partial load operation,
More informationFans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSCOIL. Centrifugal fan coil units
Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSCOIL Centrifugal fan coil units SYSCOIL Fan coil units Compact, slim fan coil units. Available
More informationfåçìëíêá~ä=~áê=åççäéêë=qelo pí~åç~êç=åççäéêë=ïáíü=`ì=íìäáåö
= pí~åç~êç=åççäéêë=ïáíü=`ì=íìäáåö O `çåíéåíë= page Model indication..................................2 Eurovent.......................................2 Capacities......................................2
More informationAir Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.
Air Cooled Water Chillers CLS 182 to 602 41 to 150 kw Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.04 R Specifications General characteristics The CLS air cooled water
More information20 to 150 mm 2-Way Automatic Flow Balancing Control Ball Valves
VFB30 Series Issue Date February 1, 2016 20 to 150 mm 2-Way Automatic Flow Balancing Control Ball Valves Low Torque Facilitates the use of smaller, less expensive directmount rotary-motion actuators Extends
More informationPrepared By : Checked By : Approved By : Page 1 out of 6
Software Name Carrier AHU - Version 1.0, Patch R1.1X UNIT MODEL GENERAL SPECIFICATIONS GENERAL LOCATION / WEIGHT UNIT DIMENSION Configuration : Quick Selection Wizard Unit Orientation : Horizontal Box
More informationTECHNICAL MANUAL SOFFIO Ducted units
TECHNICAL MANUAL SOFFIO Ducted units Page 1 INDEX 1-INTRODUCTION... 4 2-OPERATING LIMITS... 4 3- KEY TO READING CODES... 5 4-TECHNICAL SPECS... 6 5-TECHNICAL DATA (AC motors)... 7 5.1-Unit 2 pipes with
More informationChiller, Close control and Water terminals. Air Conditioning. Light Commercial, Commercial and Industrial
Chiller, Close control and Water terminals Air Conditioning Light Commercial, Commercial and Industrial Water Terminals 133 Water Terminals Fan coils & Cassette Centrifugal fan-coil SYSCOIL Ductable fan-coil
More informationAXICIAT VA. Axial fans. Smoke extraction F200/120 and F400/120. High available pressure
Smoke extraction F200/120 and F400/120 A complete range from 1250 to 95000 m 3 /s High available pressure Blade with variable pitch on stop APPLICATION Extraction or introduction of non-loaded air in the
More informationShut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.
X X testregistrierung Shut-off dampers Type ATEX-compliant parts and units For low-leakage shut-off of volume flows in potentially explosive atmospheres (ATEX) Circular shut-off dampers for shutting off
More information30GX AIR-COOLED LIQUID CHILLER
30GX-4SB 30GX080-265 AIR-COOLED LIQUID CHILLER PERFORMANCE DATA FIELD WIRING DIAGRAM 1997 Carrier Corporation Syracuse, New York 13221 Form 30GX-4SB Supersedes 30GX-3SB Printed in U.S.A. 12-97 Catalog
More informationDIRECT-AIR ILB / ILT Series Rectangular duct fans
IN-LINE DUCT FAN Series Rectangular duct fans Range of in-line rectangular duct fan manufactured from galvanised steel sheet and provided with an inspection cover that can be removed to access the motor/impeller
More informationHS17. HS17 SERIES CONDENSING UNITS 17.6 to 65.2 kw ( to Btuh) Cooling Capacity. MATCHED REMOTE SYSTEMS 50hz ENGINEERING DATA
ENGINEERING DATA ENGINEERING DATA MATCHED REMOTE SYSTEMS 50hz HS17 SERIES CONDENSING UNITS 17.6 to 65.2 kw (60 200 to 222 500 Btuh) HS17 Bulletin #490001 November 1995 Supersedes August 1994 HS17-1353
More informationlindab comfort Regula Control er
lindab comfort Regula Controller Regula Controller Control equipment for waterborne cooling and heating systems. Use Regula Mono, Duo and Regula Lon control the cooling and heating of a room in sequence
More informationAV-8020 Series Floating Control Actuated Valve
FANs 977, 1628.3 Product/Technical Bulletin AV-8020 Issue Date 0300 AV-8020 Series Floating Control Actuated Valve The AV-8020 is an electric actuator/brass valve combination that furnishes floating control
More information30GX AIR-COOLED LIQUID CHILLER
30GX-5SB 30GX080-265 AIR-COOLED LIQUID CHILLER PERFORMANCE DATA FIELD WIRING DIAGRAM 1998 Carrier Corporation Syracuse, New York 13221 Form 30GX-5SB Supersedes 30GX-4SB Printed in U.S.A. 5-98 Catalog No.
More informationDuctable Modular Fan Coil Unit VPX. Technical Brochure TM VPX-W.2GB Date : May 2004 Supersedes : TM VPX-W.1GB/08.03
Ductable Modular Fan Coil Unit VPX Technical Brochure TM VPX-W.2GB Date : May 2004 Supersedes : TM VPX-W.1GB/08.03 Design Features Presentation The VPX fan coil unit has been specially designed to meet
More informationN/** поставка оборудования для подготовки воздуха
M/0000 Series Inline /, 5/ and 5/ Spool Valves Solenoid and Pilot Actuated G / Low power solenoids High flow Unique steel reinforced seals Light weight corrosion resistant materials Technical Data Medium:
More informationABB PTTR SPAIN. Zaragoza. The product: Cast coil transformers
ABB PTTR SPAIN Zaragoza. The product: Cast coil transformers ABB BA Transformers - 1-5/7/2007 Dry Type Vacuum Cast Coil Transformer INTRODUCTION ABB BA Transformers - 2 - Product Portfolio II Dry Type
More informationTechnote. Frese OPTIMIZER - pressure independent 4-pipe coil control unit. Application. Benefits. Features.
Page of 7 Application control unit, in conjunction with the associated hydraulic set provides a complete pressure independent balancing and control group for efficient and effective individual room or
More informationPerformance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW
R410a Refrigerant SHS25 Split Ducted Model INDOOR COIL ENTERING AIR TEMP DB WB 21 2 25 27 29 1 Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE 0 5 40 45 17 2.4 1.8 11. 22.2 1.4 11.9 21.1 12.9 12.2
More informationHERZ Electronic room thermostat analog and digital
Dimension in mm 3 F799 11-3 F799 14 HERZ Electronic room thermostat analog and digital Data sheet for F799, Issue 0317 3 F799 15 3 F799 18 Mounting plate Page 1 Technical data 3 F799 11-14 3 F799 15-18
More informationPerformance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW
R410a Refrigerant SHS35 Split Ducted Model INDOOR COIL ENTERING AIR TEMP DB WB 21 23 25 27 29 31 Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE 30 35 40 45 17 34.1 21.1 11.4 32.5 20.4 11.7 30.8
More informationInsulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit
SSR with Failure Detection Function Detects failures in SSRs used for heater temperature control and simultaneously outputs alarm signals. This product supports the safe design of heater control systems,
More informationChassis Access Fans Motors Speed Control Coils The Condensate Tray Insulation Spigots Controls Enclosure Control Valves Filters Rev A
Chassis panelwork is all In House manufactured from nominally 1.2mm Galvanised steel. Where at all possible, flanges are formed inward facing to prevent exposure to bare metal edges. Sufficient forms and
More informationENGLISH NO Fan Starter INSTRUCTION MANUAL. Fan Starter 4. 4 kw 400 V 3~(+N) 50 Hz ART. NO
ENGLISH NO. 148 317 01 2000-03-09 Fan Starter INSTRUCTION MANUAL Fan Starter 4 4 kw 400 V 3~(+N) 50 Hz ART. NO. 512337 List of contents Page CE, Declaration of conformity 3 Safety 4 Technical data 4 Accessories
More informationD M S 760 C01 A A 1 1
CONTENTS Description Features Options Available Selection Method Product Data Cooling Performance Data (85 F Ambient Cooling Performance Data (95 F Ambient) Cooling Performance Data (105 F Ambient)..............................
More informationLHA LHA A ++ High efficiency air to water heat pumps EVI EVI EVI DC. Versions
LH High efficiency air to water heat pumps ++ Inverter LH -20 C Inverter +43 C Inverter 20 EVI +60 C Inverter DC INVERTER +58 C EVI +65 C COP 4,1 EVI DC INVERTER EVI DC INVERTER DC COP 4,1 INVERTER COP
More information1. Air Handler Features Page Physical data Page Available kits Page Model nomenclature Page 5
TABLE OF CONTENTS 1. Air Handler Features Page 2 2. Physical data Page 3 3. Available kits Page 4 4. Model nomenclature Page 5 5. Air handler blower performance Page 6 6. heating capacity Page 12 7. Maximum
More informationACOUSTIC CABINET FANS CVAB / CVAT Series
Range of in-line cabinet fans, manufactured from galvanised steel sheet with double thickness side panels internally lined with 17 mm thickness of fireproof fibreglass acoustic insulation (M). All models
More informationProduct Data. Features/Benefits. 45J,M,K,N,Q,R Standard, Quiet, and Low Profile Fan Powered Variable Air Volume Terminals.
Product Data 45J,M,K,N,Q,R Standard, Quiet, and Low Profile Fan Powered Variable Air Volume Terminals 90 to 3900 Cfm 45J,M 45K,N 45Q,R The 45J,M,K,N,Q,R units were designed to maintain accurate temperatures
More informationEngineering Data Manual. New : available with EC motor. High Static Pressure Ductable Fan Coil Unit. Models 07 to to 4650 m 3 /h
Engineering Data Manual New : available with EC motor VH High Static Pressure Ductable Fan Coil Unit Models 07 to 27 800 to 4650 m 3 /h General Characteristics Presentation On model VH 07, coils have 4
More information22 POINT FULLY PROGRAMMABLE HVAC CONTROLLER
UHC 300 22 POINT FULLY PROGRAMMABLE HVAC CONTROLLER OVERVIEW The HVAC building automation controls market requires a DDC controller that provides scalable, consolidated control in a fully programmable,
More informationLK Manifold Shunt VS2
LK Manifold Shunt VS2 Design LK Manifold Shunt VS2 is a shunt unit with a two way control valve used in systems with a primary pump. The shunt unit is mountable from both the left and right of LK Manifolds.
More informationTwo temperature sensors to protect against freezing and high head pressure in both the indoor evaporator and the outdoor condenser
The ZC 107 Zone Control System was designed to provide the perfect comfort control within the home. At the same time it was designed to make an airconditioning system work more efficiently and thereby
More informationCONTROL UNITS LOCAL EXTRACTORS LOCAL EXTRACTORS. Pure advantage
CONTROL UNITS LOCAL EXTRACTORS Fumex s control unit offers a good working environment, adapted to all types of facilities. The right choice of control units is also very energy-saving and provides the
More informationCOMPONENTS FOR SOLAR THERMAL SYSTEMS
COMPONENTS FOR SOLAR THERMAL SYSTEMS 2012 2 The CALEFFI SOLAR product range has been specially developed for use in solar thermal systems, where high temperatures can normally be reached and where, depending
More informationNSGV PT-1000 PORTABLE WELDING STATION I, O & M MANUAL
APPLICATION OF DUST CONTROL EQUIPMENT: CAUTION - Warning Improper operation of dust control system may contribute to conditions in the work area or facility that could result in severe personal injury
More informationElectric Coil [Make-Up Air / Displacement Ventilation / Space Heating] System
V-Series (rev. 08/17/10) Electric Coil [Make-Up Air / Displacement Ventilation / Space Heating] System Note: Optional items and/or items requiring a choice, are shown between brackets and/or parentheses
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS TEC20 TEC20H ELECTRONIC CONTROLLER BARD MANUFACTURING COMPANY Bryan, Ohio 43506 Since 1914...Moving ahead, just as planned. Manual: 2100-306D Supersedes: 2100-306C File: Volume
More informationRemote Temperature Controllers. Quick Selection Guide
Remote Temperature Controllers Quick Selection Guide A Complete Selection For A Wide Range Of Applications Electronic Standalone Controllers T775 Provide on/off, modulating, or reset control in applications
More informationType AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)
Homepage > Products > Control units > Shut-off and restriction > Shut-Off Devices > Type AK-Ex Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX) Circular shut-off
More informationDaikin McQuay. VAV Air Terminal Unit MQ FCI6, FVI5, THI5. Replacement Parts List No Revision J 07/2017
Replacement Parts List No. 700020000 Revision J 07/2017 Daikin McQuay VAV Air Terminal Unit MQ FCI6, FVI5, THI5 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.daikinapplied.com
More informationHGM501 Gen-set Controller USER MANUAL. Smartgen Technology
HGM501 Gen-set Controller USER MANUAL Smartgen Technology Contents 1. 2. 3. 4. 5. 6. 7. 8. 9. OVERVIEW... 4 PERFORMANCE AND CHARACTERISTICS... 4 TECHNICAL DATA... 5 OPERATION... 6 4.1. BUTTON DESCRIPTION...
More informationCMTE. Tangential Fan Coil Series with Electronic Controlled Motor
Tangential Fan Coil Series with Electronic Controlled Motor Designed by Very Low Electric Energy Consumption High Efficiency Extremely Low Noise Level Infra Red Remote Control Step-less Fan Speed Control
More informationHIGH EFFICIENCY HEAT RECOVERY UNITS WITH ROTARY WHEEL RHE Series
High efficient units up to 88% with rotary wheel, plug-fans with backward curved blades and EC external-rotor motor. Pre-configured control system for easy start-up. The casing is made of 5 mm, self-supporting
More informationCONTROL UNITS VEHICLE EXHAUST GASES. Pure advantages
CONTROL UNITS VEHICLE EXHAUST GASES Movex s control s offers a good working environment, adapted to all types of facilities. The right choice of control s is energy-saving and provides the lowest possible
More informationBACnet MS/TP Networking Flow Balancing Control Valves
VFB30 Series Revision Date May 8, 2013 BACnet MS/TP Networking Flow Balancing Control Valves Establishes a flow coefficient (Cv) similar to globe valves, eliminating the need for pipe size correction tables
More information2-port and 3-port valves with T-bypass PN 16
4 854 2-port valves 3-port valve with T-bypass CVTIX 2-port and 3-port valves with T-bypass PN 16 VVP45..S VMP45..S ronze CC499K valve body DN 10 and DN 15 k vs 0.63 2.5 m 3 /h Externally threaded connections
More informationSLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw
Air-to-Water Reverse Cycle Heat Pumps SLH 1202 to 3804 With Screw Compressors 261 to 775 kw 287 to 853 kw Technical Brochure TM SLH-A.2GB Date : November 2004 Supersedes : TM SLH-A.1GB/05.04 Design Features
More informationCAV controllers. Type VFL. Volume flow limiter for insertion into ducting K
.1 X X testregistrierung CAV controllers Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical
More informationELITE SERIES R-410A Ready - Multi-Position
PRODUCT SPECIFICATIONS AIR HANDLERS CBXM ELITE SERIES R-0A Ready - Multi-Position Bulletin No. 0 October 07 Supersedes June 0 Nominal Capacity -. to Tons Optional Electric Heat -. to 0 kw MODEL NUMBER
More informationDCV-RC DCV-RC. DCV-RC Room climate control unit. Room climate control SMART DAMPERS & MEASURING UNITS. Product description.
DCV-RC Room climate control SMART DAMPERS & MEASURING UNITS DCV-RC Office landscape with DCV-RC. 1(18) Contents Page DCV-RC Introduction... 3 Functional chart... 4 Dimensions, Ordering format... 5 Accessories,
More informationM-RING 24. SF6 Insulated Ring Main Unit Metal-Enclosed (LSC2A)
M-RING 24 SF6 Insulated Ring Main Unit Metal-Enclosed (LSC2A) Contents General Description Advanced facilities and process Advanced design philosophy Definition of M-RING 24 Standards Service conditions
More informationINDEX. The technical and dimensional data reported in this manual may be modified in view of any product improvement.
Ceiling-mounted fan heaters TECHNICAL MANUAL GB INDEX 1 MAIN FEATURES... 2 2 RATED TECHNICAL DATA... 3 3 HEATING CAPACITIES... 4 3.1 Heating capacity with water operation... - 11 4 STEAM OPERATION... 12
More informationSilent centrifugal air heater hot water supply
Large range : 5 to 120 Flows : 900 to 14000 m 3 /h Numerous accessories Design integrating perfectly in public buildings USE Operation in zones ES and S Extra silent and silent Forced air heating for premises
More informationCAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1
X X testregistrierung CAV controllers Type For the precise control of constant volume flow rates Circular self-powered volume flow controllers for the control of supply air or extract air in constant air
More informationSECTION AIR TERMINAL UNITS
SECTION 23 36 00 AIR TERMINAL UNITS PART 1 - GENERAL 1.1 SUMMARY A. Section includes constant volume terminal units, variable volume terminal units, dual duct terminal units, fan powered terminal units,
More informationSPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS
550.13-TG1Y(98) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS HCA300, 360, 80 & 600 5 THRU 50 NOMINAL TONS HCA80 DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece
More information42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 300 to 1400 cfm Electric heater option
42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 0 to 10 cfm Electric heater option 42DC/ 42DCD Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 0 to 00 cfm Electric heater
More informationTechnote. Frese OPTIMA Compact DN10-DN50 - pressure independent balancing & control valve. Application. Features. Benefits.
Page of 5 Frese OPTIMA Compact DN-DN5 Application Frese OPTIMA Compact pressure independent balancing & control valve (PIBCV) is used in heating and cooling systems in applications with Fan Coil Units,
More informationRE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW
Page 1 of 6 3-Phase Panel Mount 86 and 105kW Features: Benefits: 0-10Vdc, 0-5Vdc, 4-20mA or manual via potentiometer control input Over temperature protection with auto reset Enclosed panel mounting Efficient
More informationB. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.
PART 1 - GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationCentrifugal performance characteristics with axial flow pattern: RADAX VAR
High pressure in-line mixed-flow fans RADAX VAR Centrifugal performance characteristics with axial flow pattern: RADAX VAR COMPACT PRESSURE-RESISTANT UNIVERSAL In their compact casing, the RADAX VAR impellers
More informationCoil Data Nominal Current MA Nominal VA Sealed. Coil Data Nominal Current MA Nominal VA Sealed. Single Pole Double Throw (SPDT)
14/03/08 A136 Relay - General Purpose 90-293Q Enclosed fan relays used for switching single or two speed fan motors, solenoids, relays, resistive loads, heating and cooling applications and general purpose
More informationLindabPodium. Supply air beam. lindab we simplify construction
lindab we simplify construction Lindab 03.2016 Lindab Ventilation. All forms of reproduction without written permission are forbidden. is the registered trademark of Lindab AB. Lindab's products, systems,
More informationCODE MODEL 1RC9020 REC PRO 90 S RC9021 REC PRO 90 S RC9022 REC PRO 90 S RC9023 REC PRO 90 S
REC PRO 9S High efficiency Heat Recovery Units Non residential applications EFFICIENCY 9% Comply with ErP Directive 125/29/CE and EU Regulation 1253/214. Classification: Non Residential Ventilation Unit
More informationCAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1
X X testregistrierung CAV controllers Type Adjustment scale ATEX-Zertifizierung For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) Circular, mechanical self-powered
More informationQUOTATION BLADE 7 LX. Product code GEAL6S2BAA
1 of 10 Mattei rotary vane compressors are the result of 90 years of investments in research and development to improve performance and lessen the impact on the environment. Designed for industrial continuous
More informationChiller. VLC 524 to Air Cooled Condensing Units Engineering Data Manual. 154 to 347 kw
Chiller VLC 524 to 1204 Air Cooled Condensing Units Engineering Data Manual 154 to 347 kw Outstanding Strength Points Units with R410A refrigerant (it will be the real replacement of R22). As near azeotropic
More informationENR Incorporating
ENR 002-480 Incorporating R410A Refrigerant Air cooled water chillers with scroll compressors and axial fans, 2.2-480kW ENR 002-100 models inc. self-cleaning coaxial evaporators ENR 130-480 models inc.
More informationVLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw
Air-to-Water Reverse Cycle Heat Pumps VLH 504 to 1204 126 to 294 kw 133 to 307 kw Technical Brochure TM VLH-N.3GB Date : June 2005 Supersedes : TM VLH-N.2GB/07.04 Specifications Advantages Range extension
More informationtechnical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO
technical sales guide - 60Hz Taurus R Ducted Split Units UPTO HIGH AMBIENT OPERATION 52 O C Page CONTENTS Nomenclature.. 2 Description. 3 Features.. 3 Product Data. 4 Condensing Unit Cooling Performance
More informationMotor-drive mechanism, type BUL. Technical guide
Motor-drive mechanism, type BUL Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers, access to all the technical information required
More informationHEAT-RECOVERY UNITS WITH ENTHALPY/ROTARY HEAT EXCHANGER TECHNICAL MANUAL
UT REC - R HEAT-RECOVERY UNITS WITH ENTHALPY/ROTARY HEAT EXCHANGER TECHNICAL MANUAL 1 CONTENTS GENERAL FEATURES... 3 Scope of the unit... 3 Available configurations... 3 Description of the components...
More information