Installation and Operating Instructions

Size: px
Start display at page:

Download "Installation and Operating Instructions"

Transcription

1 ABS submersible mixer RW ABS submersible recirculation pumps RCP RCP SB-KA RW GB Installation and Operating Instructions

2 2 Installation and Operating Instructions Installation and Operating Instructions RW 300 RW 400 RW 650 RW 900 RW 400 LW RW 550 DM RW 650 LW RCP 250 RCP 400 RCP 500 RCP 800 SB 1236 KA SB 1237 KA

3 Installation and Operating Instructions 3 1 General Safety Transport and storage Product description RW 300/400/ RW 900/SB-KA RCP 400/ RCP Installation... 23

4 4 Installation and Operating Instructions Brackets RW/SB-KA Commisioning Maintenance

5 Installation and Operating Instructions 5

6 6 Installation and Operating Instructions 1 General 1.1 Introduction These Installation and Operating Instructions Safety Hints - m c g ATTENTION Appears at safety hints, the non-observance of which could damage the unit or affect its functioning. NOTE Used for important pieces of information. 1.2 Correct usage of the products - - of the installation and operating instructions and the safety hints 1.3 Application restrictions of RW/RCP/SB-KA Limitations: ATTENTION If cable length is less than 20 m/65 ft the max. immersion depth reduces accordingly. In special cases an immersion depth greater than 20 m/65 ft is possible. In order to do this you need the written approval from the manufacturer ABS.

7 g g For the operation of units as explosion-proof execution the following applies: Installation and Operating Instructions 7 ATTENTION RW/RCP with Ex d IIB T4 approval are not equipped with a DI in the oil chamber. ATTENTION RW 400/650 and RCP 400/500 with FM approval (NEC 500) can be equipped (as an option) with a special DI in the oil chamber. Due to the design this is not possible in RW 900 and RCP 800. For the operation of ex-rw/rcp applies: - For the operation of EX-RW/RCP with frequency inverter applies: 1.4 Application areas Application areas RW Application areas RCP -

8 8 Installation and Operating Instructions Application areas SB-KA - Hydraulics Motor AAA BB C D U VVV / W-XY.Z Ex EC; CR Material used Ex-version Gearbox ratio (only RW 900, RCP 800 and SB-KA) Motor size Number of poles in motor Motor power (P 2 [kw] x 10) Motor designation (e.g. A) Identity number Propeller type* Discharge size DN [cm] for RCP PropellerØ [cm] for RW/SB-KA Series 1.6 Technical data merged unit.

9 Installation and Operating Instructions Technical data RW 50 Hz Propeller Motor (50 Hz/400 V) Installation Mixer type Propeller diameter Speed Motor type Rated power input P 1 Rated power output P 2 Starting: Direct Starting: Star/Delta Rated current at 400 V Starting current at 400 V Cable type** Temperature monitoring Seal monitoring Ex d IIB T4 Total weight Total weight RW A 15/ RW A 15/ RW A 15/ RW A 28/ RW A 28/ RW A 28/ RW A 30/ RW A 30/ RW A 30/ RW A 30/ RW A 40/ RW A 40/ RW A 40/ RW A 50/ RW A 50/ RW A 50/ RW A 50/ RW A 50/ RW A 75/ RW A 75/ RW A 100/ RW A 110/ RW A 110/ RW A 110/ RW A 150/ RW A 150/ RW A 220/ RW A 220/ P 1 2 Other voltages available on request.

10 10 Installation and Operating Instructions Technical data RW 60 Hz Propeller Motor (60 Hz/460 V) Installation Mixer type Propeller diameter Speed Motor type Rated power input P 1 Rated power output P 2 Starting: Direct Starting: Star/Delta Rated current at 460 V Starting current at 460 V Cable type** Temperature monitoring Seal monitoring FM (NEC 500) Total weight Total weight RW A 17/ RW A 17/ RW A 32/ RW A 32/ RW A 35/ RW A 35/ RW A 35/ RW A 46/ RW A 46/ RW A 60/ RW A 60/ RW A 90/ RW A 90/ RW A 90/ RW A 120/ RW A 120/ RW A 130/ RW A 130/ RW A 130/ RW A 170/ RW A 170/ RW A 250/ RW A 250/ P 1 2

11 Installation and Operating Instructions Technical data RW- special executions Mixer type Propeller diameter Speed Motor type Rated power input P 1 Rated power output P 2 Starting: Direct Starting: Star/Delta Rated current Starting current Cable type** Temperature monitoring Seal monitoring Ex d IIB T4 Frequency Total weight RW 4033 LW A 40/ RW 6532 LW A 75/ RW 6533 LW A 100/ RW 5531 DM A 100/ RW 5531 DM A 120/ RW 5531 DM A 120/ P Technical data RCP 50 Hz Propeller Motor (50 Hz/400 V) RCP hydraulics type Propeller diameter Propeller speed H max Q max Motor type Rated input power P 1 Rated motor power P 2 Starting: Direct Starting: Star/Delta Rated current at 400 V Starting current at 400 V Cable type** Temperature monitoring Seal monitoring Ex d IIB T4 Total weight RCP A 15/ RCP A 28/ RCP A 28/ RCP A 40/ RCP A 40/ RCP A 40/ RCP A 40/ RCP A 40/ RCP A 40/ RCP A 50/ RCP A 75/ RCP A 75/ RCP A 75/ RCP A 100/ RCP A 100/ RCP A 150/ RCP A 220/ RCP A 220/ RCP A 220/ P 1 2

12 12 Installation and Operating Instructions Technical data RCP 60 Hz Propeller Motor (60 Hz/460 V) RCP hydraulics type Propeller diameter Propeller speed H max Q max Motor type Rated input power P 1 Rated motor power P 2 Starting: Direct Starting: Star/Delta Rated current at 460 V Starting current at 460 V Cable type** Temperature monitoring Seal monitoring FM (NEC 500) Total weight RCP A 17/ RCP A 32/ RCP A 32/ RCP A 46/ RCP A 46/ RCP A 46/ RCP A 46/ RCP A 90/ RCP A 120/ RCP A 120/ RCP A 120/ RCP A 130/ RCP A 250/ RCP A 250/ RCP A 250/ P Technical data SB-KA Propeller Motor Weight Flow booster type Propellerdurchdiameter Speed Motor type Rated input power P 1 Rated motor power P 2 Starting: Direct Starting: Star/ Delta Rated current at 400 V / 460 V Starting current 400 V / 460 V Cable type** Temperature monitoring Seal monitoring EEx dii BT4 Total weight SB 1236 KA A 30/ SB 1237 KA A 40/ SB 1236 KA A 35/ SB 1237 KA A 46/ P 1 2 NOTE Other voltages available on request.

13 Installation and Operating Instructions Dimensions and weights NOTE The weights of the units can be obtained from the nameplate of the unit or from the Dimensions RW Dimension RW 300 A15/28 A17/32 RW 400 A30/40 A35/46 RW 650 A50 A60 RW 650 A75 A90 RW 650 A100 A120 RW 900 A110/150 A130/170 RW 900 A220 A250 D 1 ø 300 ø 400 ø 650 ø 650 ø 650 ø 900 ø 900 D 2 ø 462 ø 560 ø 810 ø 810 ø 810 ø 1150 ø ø 158 ø ø ø ø ø ø h L L L L l l l

14 14 Installation and Operating Instructions Dimensions RCP 210,5 125, DN 250 Ø 52 Ø 267 X , min. 400 DN 400 min. 800 X 683

15 Installation and Operating Instructions DN500 min. 600 min X 865 (A50/12) 1005 (A75/12, A90/12, A100/12, A120/12) min. 700 DN 800 min X 1174 (A130/4, A150/4) 1274 (A220/4, A250/4)

16 16 Installation and Operating Instructions Dimensions SB-KA D C A C = 15 A B D SB 1236 KA SB 1237 KA D B C = 22 A B D SB 1236 KA SB 1237 KA C = 30 A B D SB 1236 KA SB 1237 KA Nameplate Figure File no Use with approved motor control that matches motor input in full load amperes. To reduce the risk of injury or electrical shock, disconnect the power be- fore raising or lowering and servicing this device Utiliser un Demarreur approuve covenant au courant a pleine charge du moteur This plate was supplied originally with certified pump FM APPROVED EXPLOSIONPROOF G k Ex d B T4 Do not open while energized Nicht unter Spannung öffnen Legend

17 Installation and Operating Instructions 17 NOTE In all communication please state type of the unit, item and serial number. 2 Safety Safety Hints 3 Transport and storage 3.1 Transport c m. - - m m m m 3.2 Transport securing devices Motor connection cable moisture protection ATTENTION These protective covers should only be removed immediately prior to connecting the pumps electrically. - ATTENTION NOTE These protective covers only provide protection against water spray or similar and are not a water tight seal. The ends of the cables should not be immersed in water, otherwise moisture could enter the connection chamber of the motor. If there is a possibility of water ingress then the cables should be secured so that the

18 18 Installation and Operating Instructions ATTENTION Take care not to damage the cable or its insulation when doing this! 3.3 Storage of the units sunlight, high humidity, aggressive dust emissions, mechanical damage, frost etc. The ABS original packaging with the relevant transport securing devices (where used) ensures optimum protection of the unit. If the units are exposed to tempera- tem, or other spaces. In the case of heavy frosts, the units and cable should not be moved if possible. When storing under extreme conditions, e.g. in tropical or desert conditions suitable additional protective steps should be taken. We would be glad to advise you further. NOTE 4 Product description 4.1 General description ABS units do not generally require any particular maintenance during storage. After long storage periods (after approx. one year), the transportation locking device on the motor shaft (not with all versions) should be disassembled. By rotating the shaft several times by hand, new lubricating oil or, depending on the version, a small amount of coolant (which also serves to cool or lubricate the mechanical seals) is applied to the sealing surfaces, thus ensuring perfect operation of the mechanical seals. The bearings supporting the motor shaft are maintenance-free. Motor Motor monitoring - Seal monitoring Operation with frequency inverters suitably selected Observe the EMC-Directive and the installation and operating instructions of the inverter manufacturer!

19 Installation and Operating Instructions Structural design RW/SB-KA RW 300/400/ RW 900/SB-KA

20 20 Installation and Operating Instructions Legend 1 Bracket 5 Stator 10 Propeller 13 Gear 4.3 Rinsing system for mechanical seal (Option) Z Z

21 Y Installation and Operating Instructions Structural design RCP RCP 400/ RCP

22 22 Installation and Operating Instructions Legend 6 Stator 9 Propeller 13 Gear 4.5 Operation with frequency inverters

23 Installation and Operating Instructions 23 U N [V] critical area non critical area 5 Installation m L[m] L = total length (from frequency inverter to motor) 5.1 Installation RW/SB-KA c c NOTE. We recommend that ABS installation accessories be used for the installation of the 5.2 Propeller assembly (only for RW 900 and SB-KA) position of the securing washers) and that the prescribed tightening torque is used!

24 24 Installation and Operating Instructions Legend 6 Propeller 5.3 Tightening torque Outer side of the 2 securing washers Inner side of the 2 securing washers Tightening torque for ABS stainless steel screws A4-70: Thread M6 M8 M10 M12 M16 M20 M24

25 Installation and Operating Instructions Installation examples RW/SB-KA Installation example with existing accessories Legend

26 26 Installation and Operating Instructions Legend

27 Installation and Operating Instructions Legend 8 9

28 28 Installation and Operating Instructions Installationsbeispiel SB-KA Fixed installation with vibration damper Vibration damper listing Mixer Part no. RW RW RW 650 RW 900/SB-KA RW 400/650 RW 900/SB-KA

29 Installation and Operating Instructions Brackets RW/SB-KA open closed Fitting of the open bracket with vertical swivelling (option) (2x) 9 (2x) 5 (2x) 4 (2x) 10 (2x) 2 (2x) 13 (2x) 10 (2x) 1 7 (2x) VKT (2x) 2 8 (2x) 9 (2x) 5 (2x) 4 (2x) 10 (2x) 10 (2x) 9 (2x) 10 (2x) 9 (2x) 6 (2x) 2 8 (2x) 5 (2x) 9 (2x) 4 (2x) 3 (2x) 11 (2x) 3 (2x) 1 VKT (2x) 10 (2x) 9 (2x) 10 (2x) 4 (2x) 9 (2x) 8 (2x) 5 (2x)

30 30 Installation and Operating Instructions Legend Fitting of the closed bracket with vertical swivelling (option) 2 (2x) (2x) 5 (2x) 9 (2x) 1 VKT (2x) 5 (2x) 3 (2x) 4 (2x) 9 (2x) 8 (2x) 6 (2x) (2x) 10 (2x) 11 (2x) 3 (2x) 1 VKT (2x) 9 (2x) Legend 6 Strap

31 Installation and Operating Instructions Guide tube lengths (square tube) RW/SB-KA - 3 Mixer/ Flow booster Maximum guide tube length (L) for an installation with square guide tube with push in type with separate guide tube with additional lifting unit lifting unit L L L RW 300 RW 400 RW 650

32 32 Installation and Operating Instructions 5.7 Installation RCP Installation example with ABS lifting unit

33 Installation and Operating Instructions Guide tube installation m

34 34 Installation and Operating Instructions Securing and positioning of the motor connection cables of the RCP m NOTE The cable holders described here are not supplied as part of the standard execution of the RCP c c.

35 Installation and Operating Instructions Lowering of the RCP along the guide tube m ATTENTION The power cable should be connected to the wire rope or chain in such a manner that it cannot become entangled in the propeller and that it is not subjected to any tension

36 36 Installation and Operating Instructions 5.8 Electrical connection m with regard to cross-sectional area and maximum voltage drop. The voltage stated on the nameplate of the pump must correspond to that of the mains c - on the nameplate. If you want to use other starting methods please consult the manufacturer. In the case a control panel is not supplied as standard the following applies: The unit must only be operated with a motor protection switch with overload relay and thermal sensors connected.

37 Installation and Operating Instructions Standard connection diagrams. mains voltage V at 50 Hz/460 V at 60 Hz U2 V2 U1 V1 PE U1 V Hz 60 Hz A 15/6 A 17/6 A 28/6 A 32/6 A 30/8 A 35/8 W2 M3 ~ W1 W1 F0 F1 DI U2 V2 W2 M3 ~ U1 V1 W1 PE U1 V1 W1 W2 U Hz 60 Hz A 40/8 A 46/8 A 50/12 A 60/12 A 75/12 A 90/12 A 110/4 A 120/12 A 130/4 A 170/4 V2 F0 F1 DI U2 V2 W2 M3 ~ U1 V1 W1 Cable 1 Di Di PE U1 V1 W Hz 60 Hz A 100/12 A 250/4 A 150/4 A 220/4 PE W2 U2 V2 F0 F1 Cable 2

38 38 Installation and Operating Instructions Lead designations Direct starting in star L1 L2 L W1 1 U1 4 U2 6 5 W2 V2 3 2 W1 V Direct starting in delta L1 L2 L W2 1 U W1 3 5 V2 U2 4 V12 c turer (See following table)....ac/...dc V ~/ V= AC 250 V AC cos = A AC cos = A I N 5.0 A Soft starter (Option) ATTENTION The units must be connected DOL when used with soft starters Legend PE U2 U1 U1 V2 V1 V1 W2 M3 ~ W1 W1 2 3 F0 F1 DI RW/RCP/SB-KA

39 Installation and Operating Instructions Testing and adjustment of soft starter: Test: Setting: Set to the lowest possible starting torqu Set to the longest possible starting time Checking direction of rotation m

40 40 Installation and Operating Instructions c m Start reaction NOTE If a number of units are connected to a single control panel then each unit must be individually checked. ATTENTION The mains supply in the control panel must have a clockwise sense of rotation. If the units are connected in accordance with the wiring diagram and the lead designations the direction of rotation will be correct Changing direction of rotation m c NOTE The direction of rotation measuring device monitors the direction of rotation of the mains supply or that of an emergency generator.

41 Installation and Operating Instructions Connection of the seal monitoring unit to the control panel ATTENTION If the DI-seal monitoring is activated the unit must be immediately taken out of service. Please contact your ABS service centre. MAINS MAINS 3 (DI) PE M2+ 3 (DI) PE M2+ M1- M Electrode X1 X2 Bulb 24V 2-5 W Electrode / MAINS 3 (DI) PE M2+ M1- Pump 2 Pump Electrode ATTENTION Maximum relay contact loading: 2 Ampere.

42 42 Installation and Operating Instructions 6 Commisioning m 6.1 Types of operation min. H min. 0,5 B ATTENTION ATTENTION The illustration is only an example. For the correct installation please contact ABS. Operation within the directly aerated area is not allowed! not vibrate heavily when in operation.

43 Installation and Operating Instructions 43 7 Maintenance m 7.1 General maintenance hints c NOTE g The maintenance hints given here are not designed for do-it-yourself repairs as special technical knowledge is required. - - ATTENTION The lifting tools like chains and shackles should be visually checked in regular inter- if required! NOTE ATTENTION The ABS warranty conditions are only valid provided that any repair work has been carried out in ABS approved workshops and where original ABS spare parts have been used. Regular checks are highly recommended and other checks are prescribed regula-

44 44 Installation and Operating Instructions 7.2 Maintenance RW/RCP and SB-KA m Faults - Possible causes: 7.3 Inspection and maintenance intervals for RW/RCP and SB-KA m PERIOD OF TIME: Regulation: once a month - -

45 Installation and Operating Instructions 45 PERIOD OF TIME: PERIOD OF TIME: PERIOD OF TIME: PERIOD OF TIME: Recommendation: once a month Regulation: every 3 months - Recommendation: every 6 months Recommendation: once a year

46 46 Installation and Operating Instructions Recurringchecks(at leastonceayear) Date Remarks Operating hours Signature Repaired on/by

47 Installation and Operating Instructions 47 Recurringchecks(at leastonceayear) Date Remarks Operating hours Signature Repaired on/by

48

Flow booster type ABS SB 900 to 2500

Flow booster type ABS SB 900 to 2500 Flow booster type ABS SB 900 to 2500 6005583 EN 08.2018 en EN 0580-I Installation and operating instructions Translation from original instruction www.sulzer.com Installation and operating instructions

More information

IP 900 W/KS & IP 900 D/KS

IP 900 W/KS & IP 900 D/KS B W/KS & D/KS Installation and operating instructions We reserve the right to make modifications in the interest of technical development (4) 15975178 GB 04/05 1 pplication reas The submersible waste-water

More information

ABS submersible sewage pump AFP

ABS submersible sewage pump AFP BS submersible sewage pump FP - Robust, reliable submersible pumps from. to kw for pumping wastewater and sewage from buildings and sites in private, commercial, industrial and municipal areas in accordance

More information

ABS lifting station Synconta

ABS lifting station Synconta 15975187GB (03/2006) 106800 GB Installation and Operating Instructions www.absgroup.com Installation and Operating Instructions 601 801 901 901L 902 902L Contents 1 General... 3 1.1 Application areas...

More information

Submersible Sewage Pumps Type ABS XFP

Submersible Sewage Pumps Type ABS XFP Submersible Sewage Pumps Type ABS XFP Main Applications Submersible sewage pump type ABS XFP is designed for municipal and industrial wastewater equipped with Premium Efficiency (IE3 level) motor for:

More information

No: En Revision Parts List. Matador O-RING KIT BASIC REPAIR KIT B_8106_180_expl_view

No: En Revision Parts List.  Matador O-RING KIT BASIC REPAIR KIT B_8106_180_expl_view No: 897386 En Revision 9.0 0 0 Parts List Matador 806.80 www.grindex.com O-RING KIT 80 BASIC REPAIR KIT 90 90 0086B_806_80_expl_view Parts List Matador 806.80 Overview Table of Contents This publication

More information

Submersible Mixer. Amamix. 60 Hz. Type Series Booklet

Submersible Mixer. Amamix. 60 Hz. Type Series Booklet Amamix 60 Hz Type Series Booklet egal information/copyright Type Series Booklet Amamix All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited or processed

More information

Submersible Sewage Pumps Type ABS XFP

Submersible Sewage Pumps Type ABS XFP Submersible Sewage Pumps Type ABS XFP Main Applications Submersible sewage pump type ABS XFP is designed for municipal and industrial wastewater equipped with Premium Efficiency (IE3 level) motor for:

More information

MOUNTING & MAINTENANCE INSTRUCTIONS FOR

MOUNTING & MAINTENANCE INSTRUCTIONS FOR 9 Pages / Page 1 MOUNTING & MAINTENANCE INSTRUCTIONS FOR THREEPHASE INDUCTION MOTORS - TYPES DM1 / DMA1 / DMA2 TABLE OF CONTENTS page 1 General information 2 2 Delivery 2 3 Mounting 2 4 Coupling 2 4.1.

More information

TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATION TECHNICAL SPECIFICATION Star/delta starter Description: The electromagnetic starters LT 3 Dxx series are devices designed for remote control, direct control and protection of induction motors coiled and

More information

Cooling Systems FLKS - 3S/1.0/W... FLKS - 3L/1.0/W DESCRIPTION

Cooling Systems FLKS - 3S/1.0/W... FLKS - 3L/1.0/W DESCRIPTION Cooling Systems FLKS - S/1.0/W... FLKS - L/1.0/W... 1. DESCRIPTION 1.1. APPLICATIONS Cooling circuits: Cooling of AC main drives Cooling of motor spindles on machining centres Cooling of transmission and

More information

Cooling shrouds. Applications. Cooling shroud for submersible borehole pumps UPA and S100B 50 Hz. Operating data. Design.

Cooling shrouds. Applications. Cooling shroud for submersible borehole pumps UPA and S100B 50 Hz. Operating data. Design. Type series booklet 3440.52/2-10 G2 Applications A cooling shroud will typically reduce the temperature of a submersible borehole pump motor by 10 C. We recommend to use a cooling shroud for the following

More information

Series description: Wilo-Drain MTC

Series description: Wilo-Drain MTC H/m Series description: Wilo-Drain MTC Wilo-Drain MTC 50 40 30 20 10 0 Design Submersible sewage pump with external macerator for intermittent and permanent operation, made of grey cast iron for stationary

More information

VERTICAL MULTI-STAGES CENTRIFUGAL PUMPS

VERTICAL MULTI-STAGES CENTRIFUGAL PUMPS Installation and Operating Instructions VERTICAL MULTI-STAGES CENTRIFUGAL PUMPS Models 1, 3, 5, 10, 15, 20, 32, 45, 64, 90, 120, 150 1. Model numbering and nameplate format 1.1 Model numbering Example:

More information

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Compact System NRGS 11-2 NRGS Original Installation Instructions English Compact System NRGS 11-2 NRGS 16-2 EN English Original Installation Instructions 810366-05 1 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 LV (Low Voltage) Directive

More information

Technical Data DML. Submersible Sewage Pumps with Single Channel Impeller. DML_Techdata_SS_V11 EBARA PUMPS AUSTRALIA PTY. LTD.

Technical Data DML. Submersible Sewage Pumps with Single Channel Impeller. DML_Techdata_SS_V11 EBARA PUMPS AUSTRALIA PTY. LTD. Technical Data DML Submersible Sewage s with Single Channel Impeller AUSTRALIA PTY. LTD. DML_Techdata_SS_V Contents -SPECIFICATIONS FEATURES & APPLICATIONS TYPICAL EXPLODED VIEW SPECIFICATIONS SELECTION

More information

Data sheet: Wilo-Drain TP 65 F 91/11 (1~230 V)

Data sheet: Wilo-Drain TP 65 F 91/11 (1~230 V) Data sheet: Wilo-Drain TP 65 F 91/11 (1~230 V) Pump curves Wilo-Drain TP 65 F - 50 Hz - 2900 rpm Unit Max. delivery head H max 9.5 m Max. volume flow Q max 36 m 3 /h Optimal delivery head H opt 6.0 m Optimum

More information

Service instructions. Contents AMD Hz 3~

Service instructions. Contents AMD Hz 3~ Service instructions AMD.07.18.1410.3 50 Hz 3~ Contents 1. Type identification... 2 1.1 Nameplate...2 1.2 Type key...2 2. Torques... 3 3. Service tools...4 3.1 Special tools...4 3.2 Standard tools...4

More information

Operation & Maintenance Manual

Operation & Maintenance Manual Operation & Maintenance Manual Submersible cutter pumps type DSP22 WETTERFRETTER 2.0 Explosion proof version Landustrie Sneek BV Tel. +31 515-486888 Pieter Zeemanstraat 6 Fax +31 515-412398 P. O. Box 199

More information

ECOMIX RW Compact, versatile submersible mixers with a wide range of applications including use in aggessive and abrasive liquids

ECOMIX RW Compact, versatile submersible mixers with a wide range of applications including use in aggessive and abrasive liquids ECOMIX RW 00 900 Compact, versatile submersible mixers with a wide range of applications including use in aggessive and abrasive liquids Can be used in every shape of tank Energy saving selfcleaning propeller

More information

SUBMERSIBLE PUMPS Lifting of wastewater containing little pollution 50 Hz

SUBMERSIBLE PUMPS Lifting of wastewater containing little pollution 50 Hz OPerating limits Flows rates up to : 1 m 3 /h Heads up to : m Temperature range : + 3 to 35 C Free passage : 10 mm ND of discharge orifice R1 1/ SBS--0 JETSON SUBMERSIBLE PUMPS Lifting of wastewater containing

More information

VERTICAL MULTI-STAGE CENTRIFUGAL PUMPS

VERTICAL MULTI-STAGE CENTRIFUGAL PUMPS Installation and Operating Instructions VERTICAL MULTI-STAGE CENTRIFUGAL PUMPS Models 1, 3, 5, 10, 15, 20, 32, 45, 64, 90 1. Model numbering and nameplate format 1.1 Model numbering Example: SBI / SBN

More information

SMD, SMG, SFG Mixers and flowmakers

SMD, SMG, SFG Mixers and flowmakers GRUNDFOS INSTRUCTIONS SMD, SMG, SFG Mixers and flowmakers 50 Hz Installation and operating instructions Installation and operating instructions http://net.grundfos.com/qr/i/98826058 English (GB) English

More information

AGRICULTURE AGITATORS

AGRICULTURE AGITATORS AGITATORS Our service range Tractor-driven agitator GIANTMIX For open and closed tanks - GIANTMIX Z3 / Z4 / Z5 / Z6 Z3 GIANTMIX Z3 Tube Ø 100 x 3 mm, galvanized Tube length 3.5-5.5 m Propeller Ø 480-580

More information

Operating manual Separator

Operating manual Separator Operating manual Separator Sheet no. AS/4.1.141.1.1 issue 20.08.2014 Contents Section Title Page 0 Introduction... 1 1 Intended use......1 2 Marking of the fitting... 1 3 Safety instructions... 2 4 Transport

More information

Operation & Maintenance Manual

Operation & Maintenance Manual Operation & Maintenance Manual Submersible pumps type LANDY DTP Explosion proof version Landustrie Sneek BV Tel. +31 515-486888 Pieter Zeemanstraat 6 Fax +31 515-412398 P. O. Box 199 info@landustrie.nl

More information

Operating Instructions

Operating Instructions Operating Instructions Pendant Light Fitting > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Instructions...3 4 Conformity to Standards...3 5 Intended Field of Application...3

More information

Operation & Maintenance Manual

Operation & Maintenance Manual Operation & Maintenance Manual Submersible pumps type LANDY DWP & Submersible pumps type LANDY DNP Explosion proof version Landustrie Sneek BV Tel. +31 515-486888 Pieter Zeemanstraat 6 Fax +31 515-412398

More information

Flygt /181. Parts List

Flygt /181. Parts List Flygt 057.09/8 Parts List Table of Contents Table of Contents Introduction... Purpose of this manual... Disclaimer... Data for ordering spare parts... Specially approved products... Qualification of personnel...

More information

Ebara Submersible Sewage Pumps (Single Channel Impeller)

Ebara Submersible Sewage Pumps (Single Channel Impeller) Ebara Submersible Sewage Pumps (Single Channel Impeller) Features and Applications Model DML 50Hz + Features! Non-clog single channel impeller Non-clog single channel impeller has 3 spherical passage and

More information

HAZMAT PUMPS TUP, GUP, IN EX explosion proof up to 620 l/min, up to 2.0 bar

HAZMAT PUMPS TUP, GUP, IN EX explosion proof up to 620 l/min, up to 2.0 bar HAZMAT PUMPS TUP, UP, IN EX explosion proof up to 620 l/min, up to 2.0 bar Hazmat pumps TUP acc. to DIN 14 424, protection class EEx II 2 c IIB T3 for inflammable and non-aggressive liquids TUP 2-1 TUP

More information

Series description: Wilo-Drain STS 40

Series description: Wilo-Drain STS 40 Series description: Wilo-Drain STS H/m 12 Wilo-Drain STS 1 8 6 2 2 6 8 1 12 1 16 Q/m³/h Design Submersible sewage pump Application Pumping of heavily contaminated fluids for: Domestic and site drainage

More information

Linear Valve Electric Actuator

Linear Valve Electric Actuator Linear Valve Electric Actuator www.powervalves.nl Company Profile Company Profile Sun Yeh Electrical Ind. Co., Ltd. was founded in 1986. We always strive for technical excellence, innovation and the highest

More information

HIB Enclosed Inverter User Guide

HIB Enclosed Inverter User Guide HIB Enclosed Inverter User Guide (0.75kW~22kW) V1.2.0 Contents 1 Safety information...1 2 Technical Data...2 3 Motor Connection...4 4 Operation...5 5 Single phase circuit diagram...7 6 Three phase circuit

More information

Mixer Model GF-37 INSTALLATION OPERATION AND MAINTENANCE MANUAL

Mixer Model GF-37 INSTALLATION OPERATION AND MAINTENANCE MANUAL Mixer Model GF-37 INSTALLATION OPERATION AND MAINTENANCE MANUAL Document Ref M-004 Rev 0 June 2004 Contents 1 - General Instructions GF 37 Gear Drive Portable Mixer Drawing No H-3022-1 1.1 Inspection 1.2

More information

Industrial air coolers for cooling & freezing applications Cu/Al

Industrial air coolers for cooling & freezing applications Cu/Al Goedhart VCI Industrial air coolers for cooling & freezing applications Cu/Al R404A - CO 2 engineering for a better world GEA Heat Exchangers Goedhart VCI The extensive range Goedhart VCI single discharge

More information

Installation and Operating Instructions

Installation and Operating Instructions Submersible Sewage Pump Type ABS XFP-PE4 to PE6 Submersible Mixed Flow Column Pump Type ABS AFLX-PE4 to PE6 Submersible Propeller Pump Type ABS VUPX-PE4 to PE6 2500-0001 1 597 2500 EN 03.2017 en Installation

More information

PAB Atex-certified centrifugal pumps

PAB Atex-certified centrifugal pumps 1 6036 EN PAB Atex-certified centrifugal pumps Technical data Delivery rate Q max = 305 l/min Delivery head H max = 20 m Temperature range 0 C to +60 C Quality Management DIN EN ISO 9001: 2008 Environmental

More information

Volute Casing Centrifugal Pumps in In-line Design with Magnetic Drive. Series CNI-M

Volute Casing Centrifugal Pumps in In-line Design with Magnetic Drive. Series CNI-M Volute Casing Centrifugal Pumps in In-line Design with Magnetic Drive Series CNI-M Usage For pumping toxic, volatile, explosive or other fluids harmful to the environment which call for service of hermetically

More information

- continuos running: max ±5%. - intermittent running: max ±10%. Voltage imbalance between phases: max 2%. Maximum number of starts per hour: 30.

- continuos running: max ±5%. - intermittent running: max ±10%. Voltage imbalance between phases: max 2%. Maximum number of starts per hour: 30. Submersible Electric Pumps GLS Series MARKET SECTORS RESIDENTIAL AND COMMERCIAL BUILDINGS, INDUSTRIES. APPLICATIONS Submersible pump for pumping clean water, surface water and wastewater containing solids

More information

AU DU PONT DE LUTTRE BRUSSELS BELGIUM PHONE: FAX: OPERATING MANUAL. Electric Fully Automatic Floor Saw FS 1218 EX

AU DU PONT DE LUTTRE BRUSSELS BELGIUM PHONE: FAX: OPERATING MANUAL. Electric Fully Automatic Floor Saw FS 1218 EX AU DU PONT DE LUTTRE 74-1190 BRUSSELS BELGIUM PHONE: 322 34 83 162 FAX: 322 34 83 136 OPERATING MANUAL Electric Fully Automatic Floor Saw FS 1218 EX 2 Important information before you start! When the machine

More information

Industrial air coolers for cooling & freezing applications StSt/Al

Industrial air coolers for cooling & freezing applications StSt/Al Goedhart VRB / VRZ Industrial air coolers for cooling & freezing applications StSt/Al NH 3 - CO 2 engineering for a better world GEA Heat Exchangers Goedhart VRB/VRZ The range Goedhart VRB/VRZ single discharge

More information

SUBMERSIBLE PUMPS EFFLUENT DISPOSAL RANGE 4 poles - 50 Hz

SUBMERSIBLE PUMPS EFFLUENT DISPOSAL RANGE 4 poles - 50 Hz operating limits Flow rates up to: m 3 /h Head up to: m CL Range of temperature of the liquid: +3 to C* Density of the liquid:,5 max. ph of the liquid: 3- Maximum immersion: Maximum particle size: m Ø

More information

Overload Relays. SIRIUS 3RU2 Thermal Overload Relays 3RU2 up to 40 A for standard applications. 5/78 Siemens IC Overview

Overload Relays. SIRIUS 3RU2 Thermal Overload Relays 3RU2 up to 40 A for standard applications. 5/78 Siemens IC Overview SIRIUS 3RU2 Thermal Overload Relays 3RU2 up to 40 A Overview 1 2 3 4 6 1 2 NSB0_0207a Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors.

More information

Instruction Manual. * We reserve the right to amend specification without prior notice.

Instruction Manual. * We reserve the right to amend specification without prior notice. An IS 9001:200 certified company by Instruction Manual SSW SERIES 0.7 KW / 0.5 HP to 11 KW / 15 HP INDRA HYDR TECH PUMPS PVT. LTD. 16, 1st Floor, th Cross, 4th Phase, Peenya Industrial Area, Bengaluru

More information

DRAINAGE PUMPS Type RLV

DRAINAGE PUMPS Type RLV DRAINAGE PUMPS Type RLV Owner s manual Identification Each pump has his code engraved on the nameplate. Type Serial V Pn-kW A Q l/1 O IP H mo µf RPM Hz kg Year fabriquant Type Code Serial Serial V nominal

More information

HOMA Product Range. Electric Submersible Sewage Pumps Ranges K, KX. The source for world wide pump technology. Discharge Size DN 200 up to DN 400

HOMA Product Range. Electric Submersible Sewage Pumps Ranges K, KX. The source for world wide pump technology. Discharge Size DN 200 up to DN 400 The source for world wide pump technology HOMA Product Range Electric Submersible Sewage Pumps Ranges K, KX Submersible drainage pumps Contractor pumps Drainage pumps for emergency application Deepwell

More information

Revision 1.0 Parts List Master

Revision 1.0 Parts List Master Revision.0 www.grindex.com Parts List 805.8 Master Table of Contents Table of Contents Introduction... Specially products... Product Description...3 The data plate...3 Parts... 4 Exploded view... 4 List

More information

Deepika Enterprises.

Deepika Enterprises. +91-8048572696 Deepika Enterprises https://www.deepikaenterprises.co.in/ We are prominent suppliers, traders, wholesalers and distributors of an extensive range of Electrical and Automation Products. Owing

More information

Mounting & Maintenance Instructions OMT1 & OMT2 Motors

Mounting & Maintenance Instructions OMT1 & OMT2 Motors Mounting & Maintenance Instructions OMT1 & OMT2 Motors Seite 1 von 10 Inhalt Seite 1 General information 3 2 Delivery 3 3 Mounting 3 4 Coupling 3 4.1 Direct coupling 3 4.2 Indirect coupling 4 4.2.1 Flat

More information

GRUNDFOS PRICE LIST 2017 WASTEWATER. Effective date: January 1, 2017

GRUNDFOS PRICE LIST 2017 WASTEWATER. Effective date: January 1, 2017 GRUNDFOS PRICE LIST 2017 WASTEWATER 2017 Effective date: January 1, 2017 TABLE OF CONTENTS WASTEWATER SMALL AND LARGE PUMPS, CONTROLS & ACCESSORIES WASTEWATER LARGE SEG Type Key...4-1 SEG Submersible Grinder

More information

JUNG PUMPEN MULTICUT SEWAGE PUMPS

JUNG PUMPEN MULTICUT SEWAGE PUMPS APPLICATION Centrifugal submersible sewage pumps fitted with the MultiCut cutting system are used as stationary appliances for backpressure protection of detached houses. They are suitable for pumping

More information

Instruction Manual. * We reserve the right to amend specification without prior notice.

Instruction Manual. * We reserve the right to amend specification without prior notice. An IS 9001:200 certified company by Instruction Manual SSW SERIES 0.7 KW / 0.5 HP to 11 KW / 15 HP Declaration of Conformity Company Name Indra Hydro Tech Pumps Pvt. Ltd. Address 16, 4th Phase, th Cross,

More information

Series description: Wilo-Drain TM/TMW/TMR 32

Series description: Wilo-Drain TM/TMW/TMR 32 Series description: Wilo-Drain TM/TMW/TMR 32 H[m] 10 Wilo-Drain TM /TMR /TMW 32 8 6 TM 32/7 4 TM 32/8 TMW 32/8 2 TMW 32/11 TMR 32/8 TMR 32/11 0 0 2 4 6 8 10 12 Q[m³/h] Design Basement drainage pump, water-cooled

More information

ASYNCHRONOUS MOTORS THREE-PHASE MOTORS SINGLE-PHASE MOTORS BRAKE MOTORS INSTRUCCIONES DE SERVICIO OPERATING INSTRUCTIONS 2016

ASYNCHRONOUS MOTORS THREE-PHASE MOTORS SINGLE-PHASE MOTORS BRAKE MOTORS INSTRUCCIONES DE SERVICIO OPERATING INSTRUCTIONS 2016 ASYNCHRONOUS INSTRUCCIONES DE SERVICIO MOTORS THREE-PHASE MOTORS SINGLE-PHASE MOTORS BRAKE MOTORS OPERATING INSTRUCTIONS 2016 3006/16 en Ed.02.2016 Read these Operating Instructions before you transport,

More information

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS Government Approved Test Laboratory (Previously AIA) Reg No: 1999/027771/07 Equipment: Manufacturer: Type: ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION

More information

Operating Instructions

Operating Instructions Operating Instructions Table of contents Table of contents... 1 1. Declaration... 1 2. Warranty and liability... 2 3. Gear description... 2 4. Gear types... 2 5. Safety... 3 5.1 General safety information...

More information

Industrial air cooler VCI Cooling/Freezing

Industrial air cooler VCI Cooling/Freezing Industrial air cooler VCI Cooling/Freezing Cu/Al - R404A GEA Refrigeration Goedhart Goedhart VCI The extensive range Goedhart VCI single discharge ceiling mounted industrial air coolers are available with

More information

Flygt /181. Parts List

Flygt /181. Parts List Flygt 045.091/181 Parts List Table of Contents Table of Contents Introduction... Purpose of this manual... Disclaimer... Data for ordering spare parts... Specially approved products... Qualification of

More information

Operation & Maintenance Manual

Operation & Maintenance Manual Operation & Maintenance Manual Submersible mixers type LANDY DWM & Submersible mixers type LANDY DNM Landustrie Sneek BV Tel. +31 515-486888 Pieter Zeemanstraat 6 Fax +31 515-412398 P. O. Box 199 info@landustrie.nl

More information

ROTAX Engine Type 914 F

ROTAX Engine Type 914 F AIRCRAFT ENGINES ation Manual for ROTAX Engine Type XXX WARNING Before starting with the engine installation, please, read the ation Manual completely as it contains important safety-relevant information.

More information

Operating Instructions

Operating Instructions Operating Instructions Pendant Light Fitting > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Notes Regarding Safety...3 4 Intended Area of Application...4 5 Technical Data...5

More information

G72x Series Direct Spark Ignition Controls

G72x Series Direct Spark Ignition Controls Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin G72x Issue Date 1299 G72x Series Direct Spark Ignition Controls Figure 1: G72x Direct Spark Ignition

More information

QAA 132 Operating Manual for Heat Tracing System ELSR-MA and ELSR-WA

QAA 132 Operating Manual for Heat Tracing System ELSR-MA and ELSR-WA QAA 132 Operating Manual for Heat Tracing System ELSR-MA and ELSR-WA eltherm Canada Inc. 1440 Graham s Lane, Unit 5 Burlington Ontario L7S 1W3 Canada Phone: +1 (289) 812-6631 Fax: +1 (844) 325-6750 E-Mail:

More information

SIRIUS 3RU2 Thermal Overload Relays

SIRIUS 3RU2 Thermal Overload Relays Overview 1 2 3 4 6 1 2 NSB0_0207a Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors. The overload relay can be connected directly to

More information

Flygt low-speed mixers OUTSTANDING EFFICIENCY

Flygt low-speed mixers OUTSTANDING EFFICIENCY Flygt low-speed mixers OUTSTANDING EFFICIENCY INTRODUCTION Energy-efficient mixing Advantages of Flygt low-speed mixers Rising to the mixing challenge All mixing applications require varying degrees of

More information

CENTRIFUGAL IMMERSION PUMPS

CENTRIFUGAL IMMERSION PUMPS CENTRIFUGAL IMMERSION PUMPS FLUX CENTRIFUGAL IMMERSION PUMPS QUALITY THAT SETS STANDARDS Manufactured at our main plant, these ranges of immersion pumps are the result of extensive product and process

More information

Data sheet: Wilo-Drain TP 65 F 109/22 (3~400 V)

Data sheet: Wilo-Drain TP 65 F 109/22 (3~400 V) Data sheet: Wilo-Drain TP 65 F 109/22 (3~400 V) Pump curves Wilo-Drain TP 65 F - 50 Hz - No. of poles: 2 Unit Max. delivery head H max 14.5 m Max. volume flow Q max 52.0 m 3 /h Optimal delivery head H

More information

SL1, SLV kw, 50 Hz GRUNDFOS INSTRUCTIONS. Service instructions

SL1, SLV kw, 50 Hz GRUNDFOS INSTRUCTIONS. Service instructions GRUNDFOS INSTRUCTIONS SL1, SLV 1.1-11 kw, 50 Hz Service instructions Installation and operating instructions in English and other languages for 50 Hz http://net.grundfos.com/qr/i/96771279 English (GB)

More information

No: En Revision Parts List. MINEX O-RING KIT BASIC REPAIR KIT E_8101_171_expl_view

No: En Revision Parts List.  MINEX O-RING KIT BASIC REPAIR KIT E_8101_171_expl_view No: 89850 En Revision 6.0 0 0 Parts List MINEX 80.7 www.grindex.com O-RING KIT BASIC REPAIR KIT 0008E_80_7_expl_view Parts List MINEX 80.7 Overview Table of Contents This publication contains the following

More information

For Operation in the Control Cabinet 3RW Soft Starters

For Operation in the Control Cabinet 3RW Soft Starters General Data Overview The advantages of the SIRIUS soft starters at a glance: Soft starting and smooth ramp-down 1) Stepless starting Reduction of current peaks Avoidance of mains voltage fluctuations

More information

NB NB 1511 NB NB 4031 TRUE ON-LINE DOUBLE CONVERSION UPS

NB NB 1511 NB NB 4031 TRUE ON-LINE DOUBLE CONVERSION UPS NB 0811 - NB 1511 NB 0831 - NB 4031 TRUE ON-LINE DOUBLE CONVERSION UPS LEN.MAN.UPS.069 Rev.2.00/2002 CONTENTS Safety Instructions 1 Introduction 3 2.1 FEATURE 3 2.2 UPS modules 4 How the UPS works 5 3.1

More information

Parts List. MINOR

Parts List.  MINOR No: 88600 En Revision 3.0 0 Parts List MINOR 803.80 www.grindex.com 5 8 8 6 7 8 O-RING KIT 80 BASIC REPAIR KIT 90 6-68 5 6 7 9 0 50-5 3 5 6 7 8 9 30 300 39-35 85 303 86 3 33 3 35 36 37 38 83 39 0 8 N 68

More information

Quality wins through!

Quality wins through! Components for biogas Quality wins through! Offer benefits Harvest profits with Eisele More than 25 years of experience with Biogas plants The robust and powerful pumps and submersible mixers of EISELE

More information

Type Type 1001 Transducers. I/P & E/P Transducers

Type Type 1001 Transducers. I/P & E/P Transducers Type 1001 I/P & E/P Description The Type 1001 is a patented family of electropneumatic instruments that is used to reduce a supply pressure to a regulated output pressure which is directly proportional

More information

SERVICE MANUAL SECOH AIR PUMPS

SERVICE MANUAL SECOH AIR PUMPS SERVICE MANUAL SECOH AIR PUMPS (SHOWN AT EL SERIES) MODEL: SLL-20, 30, 40 & 50 EL-60, 80-15, 80-17 & 100 EL-120W, 150 & 200-0 - This manual is not meant to be included in the scope of delivery (for this

More information

Sewage transport Submersible pumps

Sewage transport Submersible pumps Series description Wilo-Rexa FIT Available from January 2012 Construction Submersible sewage pump with cast iron hydraulics and stainless steel motor Type key Example: Wilo Rexa FIT V06DA-110/EAD1-2-T0015-540-A

More information

AEEB AEVB LOW VOLTAGE SERIES Three-Phase Squirrel Cage Induction Motor Conforming to SS530 (Occasional Use) Conforming to IE1

AEEB AEVB LOW VOLTAGE SERIES Three-Phase Squirrel Cage Induction Motor Conforming to SS530 (Occasional Use) Conforming to IE1 AEEB AEVB LOW VOLTAGE SERIES Three-Phase Squirrel Cage Induction Motor Conforming to SS530 (Occasional Use) Conforming to IE1 STANDARD AND SPECIFICATION Performance: Meet the requirement of Singapore standard

More information

Operating Instructions Flexdip CYA112

Operating Instructions Flexdip CYA112 BA00432C/07/EN/13.13 71207066 Products Solutions Services Operating Instructions Wastewater assembly About this document Safety messages The structure, signal words and safety colors of the signs comply

More information

DP A.2.50B. Grundfos pump GRUNDFOS DATA BOOKLET

DP A.2.50B. Grundfos pump GRUNDFOS DATA BOOKLET GRUNDFOS DATA BOOKLET DP10.65.26.A.2.50B Grundfos pump 96106544 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/dpfam/96106544/dp10-65-26-a-2-50b.html

More information

Parts List. MAJOR

Parts List.  MAJOR No: 8860 En Revision.0 0.0 Parts List MAJOR 80.80 www.grindex.com 5 8 8 6 7 8 O-RING KIT 80 BASIC REPAIR KIT 90 6-68 5 6 7 9 0 50-5 3 5 6 7 8 9 30 300 39-35 85 303 86 3 33 3 35 36 37 38 83 39 0 8 N 68

More information

Flygt low-speed mixers. outstanding efficiency

Flygt low-speed mixers. outstanding efficiency Flygt low-speed mixers outstanding efficiency Introduction Energy-efficient mixing Advantages of Flygt low-speed mixers Rising to the mixing challenge All mixing applications require varying degrees of

More information

No: En Revision Parts List. MAJOR MSHA A_8103_8104_081_expl_view

No: En Revision Parts List.  MAJOR MSHA A_8103_8104_081_expl_view No: 882089 En Revision 2.0 202.0 Parts List MAJOR MSHA 80.08 www.grindex.com 2 3 5 6 7 8 9 0 7 8 9 2 3 5 6 2 3 5 6 7 8 9 50 5 52 53 20 2 22 23 2 25 26 27 28 29 30 5 55 56 57 58 59 60 6 62 63 500 3 32 33

More information

Gerotor pump, fixed displacement volume

Gerotor pump, fixed displacement volume Gerotor pump, fixed displacement volume RE 10545/12.11 1/12 Type GZ Component series 1X Maximum operating pressure 15 bar Maximum displacement 140 cm³ H7572_d Table of contents Contents age eatures 1 Ordering

More information

Technical Data. Dimensions

Technical Data. Dimensions Model Number Features 40 mm flush 4-wire DC ATEX-approval for zone 2 and zone 22 S Technical Data specifications Switching element function PNP NO/NC Rated operating distance s n 40 mm Installation flush

More information

PHP-C Pressureless Expansion System Overview Description: The PHP-C balanced pressure expansion equipment is sized according to the total system volume and the boiler or chiller load. The PHP-C vessel

More information

Installation, Maintenance and Operation manual 4 Submersible sand fighter pump. Type: SSFP - Series

Installation, Maintenance and Operation manual 4 Submersible sand fighter pump. Type: SSFP - Series Installation, Maintenance and Operation manual 4 Submersible sand fighter pump Type: SSFP - Series Prakash Pump Warranty We guarantee our products, for the period of 24 months from the date of purchase.

More information

SECTION ELECTRIC MOTOR ACTUATORS FOR VALVES

SECTION ELECTRIC MOTOR ACTUATORS FOR VALVES SECTION 40 92 10 - ELECTRIC MOTOR ACTUATORS FOR VALVES PART 1 - GENERAL A. Description This section includes materials and installation of electric motor actuators for valves. B. Submittals 1. Submit shop

More information

JUNG PUMPEN US SUBMERSIBLE DRAINAGE PUMPS

JUNG PUMPEN US SUBMERSIBLE DRAINAGE PUMPS APPLICATION The centrifugal submersible drainage pumps US 62-251 can be used wherever sewage water with solids up to 10 mm particle size occurs, e.g. in collecting sumps for ground water, or in permanent

More information

SWE SERIES (IE3) WONDER ELECTRIC MOTOR (S) PTE LTD. Energy Saving Low Noise Environmental Friendly IEC Dimension Low Vibration European Design

SWE SERIES (IE3) WONDER ELECTRIC MOTOR (S) PTE LTD. Energy Saving Low Noise Environmental Friendly IEC Dimension Low Vibration European Design RANGE OF PRODUCTS Three phase asynchronous squirrel-cage & slip ring induction motors Three phase asynchronous self-braking motors Hollow shaft rotor motors Cooling tower motors High motors, (IE2) (IE3)

More information

Amaline Submersible motor recirculation pump with ECB propeller 50 Hz Applications Designation Amaline P / 74 UM G Pump design

Amaline Submersible motor recirculation pump with ECB propeller 50 Hz Applications Designation Amaline P / 74 UM G Pump design Type series booklet 1594.5/8--EN Amaline Submersible motor recirculation pump with ECB propeller Hz Applications Recirculation of activated sludge from nitrification stages into denitrification stages

More information

ACCESSORIES CATALOGUE

ACCESSORIES CATALOGUE ACCESSORIES CATALOGUE Spray technology Fluid handling Material extrusion Injection www.wiwa.com 1 WIWA ram presses and single post lifts 1.1 WIWA single and twin post ram presses WIWA holder for ram presses

More information

TPAK Series COOLANT PUMP

TPAK Series COOLANT PUMP TPAK Series COOLANT PUMP Instruction Manual ISO 9001 Certified WALRUS PUMP CO., LTD. EC Declaration of Conformity Manufacturer: Walrus Pump Co., Ltd. Address: No.83-14, Dapiantou, Sanzhi Dist., New Taipei

More information

SP A, SP. Submersible pumps Submersible motors Accessories. 50 Hz

SP A, SP. Submersible pumps Submersible motors Accessories. 50 Hz SP A, SP Submersible motors Accessories For raw water supply, irrigation systems, groundwater lowering, pressure boosting and various industrial applications. 5 Hz TM 7318 2298 Contents General data Performance

More information

Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps

Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps EI-700-008 Rev -- Table of Contents Safety Guidelines 3 Caution 4 Wiring 4 Maintenance 4 Nameplate format 4 Prior to Operation

More information

Orbipore CPS91 and CPS91D

Orbipore CPS91 and CPS91D Technical Information Orbipore CPS91 and CPS91D ph electrodes, analog or with digital Memosens technology With open aperture for heavily soiled media, optional built-in temperature sensor Application Chemical

More information

3RW Soft Starters. General data. 6/4 Siemens LV

3RW Soft Starters. General data. 6/4 Siemens LV General data Overview The advantages of the SIRIUS soft starters at a glance: Soft starting and smooth ramp-down 1) Stepless starting Reduction of peaks Avoidance of mains voltage fluctuations during starting

More information

Borehole Submersible Pumps. Installation and Operating Instructions

Borehole Submersible Pumps. Installation and Operating Instructions Borehole Submersible Pumps Installation and Operating Instructions These instructions apply to STAIRS submersible pumps, type SP. Read these instructions carefully before beginning installation 1. Delivery

More information

No: En Revision Parts List. MINETTE O-RING KIT BASIC REPAIR KIT F_8102_171_expl_view

No: En Revision Parts List.  MINETTE O-RING KIT BASIC REPAIR KIT F_8102_171_expl_view No: 89837 En Revision 6.0 202 0 Parts List MINETTE 802.7 www.grindex.com O-RING KIT BASIC REPAIR KIT 2002F_802_7_expl_view Parts List MINETTE 802.7 Overview Table of Contents This publication contains

More information

Operating instructions for PXFLOW sewage pumps

Operating instructions for PXFLOW sewage pumps Operating instructions for PXFLOW sewage pumps Standard units PAPANTONATOS S.A. Roumelis & Kapetan Zacharia (ex. Afon Ntouna) 1 13677 Acharnes Attiki - Greece Tel: (+30) 210 2431111, FAX: (+30) 210 2431601

More information