DWKL Double-wall stainless steel exhaust system

Size: px
Start display at page:

Download "DWKL Double-wall stainless steel exhaust system"

Transcription

1 DWKL Double-wall stainless steel exhaust system

2 INDEX JEREMIAS CONTENTS DW - Double-wall chimneys Introduction Technical specifications Installation instructions DW-KL Products Adapters Supports Straight lengths Adjustable lengths Elbows Tees Grease tees Wye tees Tee caps Increasers Reducers Flashings Terminations Accessories Offset tables Sample systems Warranty statement 2

3 INTRODUCTION JEREMIAS EXHAUST SYSTEMS Jeremias Models DWKL and SWKL are factory built stainless steel venting systems for various types of appliances. The Model DWKL is Double Wall and Model SWKL is Single Wall. The KL is derived from the original spelling of Konical, for the Conical Joint. Each may be intermixed in the same vent system assuming proper clearances and other installation guidelines are maintained for each system. All DWKL Models and variations are intended for use in exhausting various appliances to the outdoors. There are also many other applications and uses including, but not limited to the following: boiler stacks, engine exhausts, turbines, commercial kitchen exhausts, grease ducts, pizza ovens, coffee roasters, chimney liners, fireplace chimneys, laundry dryer vents, fume venting, industrial oven and process stacks, incinerator exhausts, paint booth exhausts, particle conveying, chutes, and ventilation ducts. STRONG OPEN INTERNATIONAL 40 Years of Experience Jeremias is one of the world`s leading manufacturers of flue and chimney systems for the exhaust of gases and ventilation, covering all kinds of domestic, commercial and industrial applications. Jeremias Group product range includes over fifty (50) different CE or UL certified systems covering commercial and domestic applications complimented by freestanding Industrial steel chimneys up to 10 feet in diameter. Jeremias offers its clients a wide range of high quality products, technical support for projects, and stack sizing software. With over 40 years of experience in the venting and component exhaust industries, Jeremias has seven (7) manufacturing plants in six (6) different countries worldwide. Jeremias today has more than 1,000 employees and is proud of its German engineering origins, and fortunately is now also manufactured in the USA from 100 % local materials! Here is North America, Jeremias Inc. focuses primarily on high pressure exhaust systems for commercial and industrial applications. Research and Development Jeremias has over fifty (50) CE Certified exhaust and chimney systems worldwide for domestic, commercial, and industrial applications. CE Certification is the mandatory conformity safety testing for products sold throughout Europe and other parts of the world. In North America, Jeremias employs only Underwriters Laboratories (UL) for testing, certifications, and listings to all applicable UL and ULC Standards. 3

4 INTRODUCTION JEREMIAS EXHAUST SYSTEMS Opened in 2013, the Jeremias R&D Lab in Logan, OH has the industry s most experienced lab technicians on staff and incorporates the latest equipment and technologies. This laboratory enables Jeremias to provide industry leadership with a continued focus on new factory-built exhaust applications and unique listings. Jeremias is constantly bringing new innovations to the marketplace and our Logan laboratory enables us to accomplish these changes quickly and effectively. All Stainless Steel Construction The standard 444 stainless steel (EN ) inner wall is the new standard for high temperatures and also corrosion resistant to flue gas condensation. 444 stainless steel provides a better higher temperature solution over austenitic 304 or 316 stainless steels due to lower expansion coefficient value, meaning no cracking from less expanding oxides. 444 stainless steel has very good resistance to pitting corrosion in chloride media, much better than 304 (EN ) and 316 (EN ) stainless steels, and even better than 316L (EN ) stainless steel. 444 stainless steel also has a higher minimum proof strength than 304 stainless steel in combination with lower work hardening behavior. The outer jacket is always made of stainless steel. Type 304 stainless steel with a bright annealed finish is standard. All accessories (including support plates and angle rings) are also made of stainless steel. This means there is no cross contamination in the factory from carbon steel cutting/welding. Jeremias cleans all external welds to assure the customer clearly sees the quality standard we are setting. Jeremias backs our exhaust systems with an industry s first Twenty-Five (25) Year Standard Warranty. Largest Joint Connection Surface Area Model DWKL is a cylindrical, factory-built, modular venting system that incorporates a steel to steel conical joint and clamp system for quick and easy assembly in the field. A Jeremias supplied high temperature ceramic lubricating and assembly paste is applied on the conical joint to assure the best steel to steel connection; and it is then tapped into place creating a gastight and liquid-tight seal. The conical joints have a 2.2 steel to steel surfacearea at each connection allowing greater stiffness, sealing, and durability compared to ½ flange to flange systems. For example, 6 I.D. DWKL has a square inch overlap at each joint where a ½ flanged system has only a 9.42 square inch overlap. UL Testing resulted in the industry s first 90 W.C. pressure capability after continuous 1400 F flue gas temperatures. The double wall Model DWKL is insulated with 1¼ thick compressed fiber insulation which allows the inner and outer pipes to stay aligned, without the use of additional clips or brackets. On other designs, clips or brackets act as a thermal bridge from the inner wall to outer jacket. With no additional thermal bridge at the joint there are no hot spots at pipe and fitting connections. 4

5 TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model and Part Identifications DWKL, Double Wall, universal, for all applications (5 Ø-36 Ø) Available in many thicknesses of insulation DWKL-Lt, Double Wall Light, universal, for all applications (3 Ø-18 Ø) DWKL-Rx, Double Wall, Roxul, for 1200 F Max applications (5 Ø-36 Ø) Available in many thicknesses of insulation DWKL-Vt, Double Wall Vent, Roxul Insulation, for 1200 F Max applications (3 Ø-18 Ø) Example 1: DWKL8-36L for an 8 inch diameter Model DWKL double wall, 36 inches in length Example 2: DWKL12-90BT-Vt for a 12 inch diameter Model DWKL-Vt double wall 90 degree Boot Tee Material Options and Thicknesses DWKL Inner Liner: > thick Type 444 stainless steel ; 5 Ø through 36 Ø (under 5 Ø use -Lt) Outer Jacket: > thick Type 304 stainless steel ; 5 Ø through 24 Ø > thick Type 304 stainless steel ; 26 Ø through 36 Ø Insulation: SuperWool- 1.5 blanket 8 PCF Fiber compressed to 1.25 thick (9.6 PCF net effective) Outer Jacket: > thick Type 304 stainless steel ; 3 Ø through 18 Ø Insulation: SuperWool- 1.5 blanket 8 PCF Fiber compressed to 1.25 thick (9.6 PCF net effective) DWKL- Rx Inner Liner: > thick Type 444 stainless steel ; 5 Ø through 36 Ø (under 5 Ø use -Vt) Outer Jacket: > thick Type 304 stainless steel ; 5 Ø through 24 Ø > thick Type 304 stainless steel ; 26 Ø through 36 Ø Insulation: Roxul thick cut 8 PCF Mineral Wool DWKL- Vt Inner Liner: > thick Type 444 stainless steel ; 3 Ø through 18 Ø (over 18 Ø use -Rx) Outer Jacket: > thick Type 304 stainless steel ; 3 Ø through 18 Ø Insulation: Roxul thick cut 8 PCF Mineral Wool DWKL- Lt Inner Liner: > thick Type 444 stainless steel ; 3 Ø through 18 Ø (over 18 Ø use regular DWKL) 5

6 TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Underwriters Laboratories Listings UL File Number for All Listings: MH59917 United States: DWKL & DWKL-Lt Double Wall with compressed fiber 1. UL-103 Standard, Building Heating Appliance Chimney 2. UL-103 Standard, Additional Type HT Listing 3. UL-2561 Standard, 1400F Chimney Listing 4. UL-103 & UL-2561 Standards, Additional Positive Pressure Listing to 90 WC after 1400 F 5. UL-1978 Standard, Grease Duct 6. UL-1738 Standard, Venting Systems for Gas-Burning Appliances, Categories II, III and IV 7. UL-441 Standard, Gas Vents 8. UL-641 Standard, Type L Low-Temperature Vent UL & ULC Listings Matrix: CRITERIA DWKL DWKL-Lt DWKL-Vt UL-103 Building Heating Appliance Chimney ULC/ORD-C959 Industrial Type 540 C Chimney X X X UL-1978 Grease Duct ULC-S662 Grease Duct X X UL-1738 Special Gas Vent ULC-S636 Gas Vent X X X DWKL-Vt & DWKL - RX Gas Vents with cut mineral wool insulation 1. UL-103 Standard, Building Heating Appliance Chimney 2. UL-103 Standard, Additional Positive Pressure Listing to 90 WC after 1400 F 3. UL-1738 Standard, Venting Systems for Gas-Burning Appliances, Categories II, III and IV 4. UL-441 Standard, Gas Vents 5. UL-641 Standard, Type L Low-Temperature Vent Optional 400 F UL-1738 Special Gas Vent X X X Optional Plastic (PVC, CPVC, PP) Special Gas Vent X X X UL-1777 Chimney Liner ULC-S635 Lining Systems for Existing Chimneys Notes: 1. UL only, not ULC 2. UL (gas/oil), ULC (all fuels) Operating Pressures All Jeremias Inc. models have been evaluated and Listed by UL for positive pressures up to 90 W.C. internal static pressure with exposure up to 1400 F internal continuous temperatures. 6

7 TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Code and Standards When installed per their instructions, all Jeremias Inc. models are code compliant with the following codes and standards: > NFPA 31 > NFPA 37 > NFPA 54 > NFPA 96 > NFPA 211 > UMC > CMC > CSA-B139 > CSA-B149 > IMC > IFGC > ULC-S650 The following agencies or associations produce codes, standards, or guidelines by which all Jeremias Inc. Models may be installed and used: > ASHRAE (American Society of Heating, Refrigerating and Air Conditioning Engineers) > CSA (Canadian Standards Association) > IAPMO (International Association of Plumbing and Mechanical Officials) > ICC (International Code Congress) > NFPA (National Fire Protection Association) > UL (Underwriters Laboratories, Inc.) > ULC (Underwriters Laboratories of Canada) conical joint and clamp system for quick and easy assembly in the field. A Jeremias supplied high temperature ceramic lubricating and assembly paste is applied on the inner wall conical joint to assure the best steel to steel connection. The double wall models are insulated with 1½ thick fiber (compressed to 1¼ ) or 1¼ cut mineral wool which allows the inner and outer pipes to stay aligned. Models DWKL/DWKL-Lt/DWKL-Vt Joint Assembly Detail INNER LINER 1 ¼ INSULATION OUTER JACKET LOCKING BAND (LB) STEEL TO STEEL SURFACE JOINING Operating Temperatures CRITERIA UL-103 Building Heating Appliance Chimney ULC/ORD-C959 Industrial Type 540 C Chimney UL-1978 Grease Duct UL-1738 Special Gas Vent ULC-S636 Gas Vent Optional 400 F UL-1738 Special Gas Vent Optional Plastic (PVC, CPVC, PP) Special Gas Vent UL-1777 Chimney Liner ULC-S635 Lining Systems for Existing Chimneys PERMITTED TEMPERATURES 1000 F (540 C) Continuous 1400 F (760 C) Intermittent 500 F (260 C) Continuous 2000 F (1093 C) for 30 Minutes 550 F (288 C) Continuous 400 F (204 C) Continuous 148 F (64 C) Continuous for PVC 194 F (90 C) Continuous for CPVC 248 F (120 C) Continuous for PP UL-1777: 570 F Continous ULC-S635: 650 C Continous Further features of the Jeremias double wall insulated systems include: a) Reduced clearance to combustibles b) Reduced outer pipe skin temperatures c) Reduced building heat gain d) Increased efficiencies of energy recovery systems e) Reduced noise levels caused by high velocity exhausts f) Enhanced chimney draft Sizing/Pressure Calculations Joint Detail All Jeremias Inc. models are cylindrical, factory-built, modular venting systems that incorporate a steel to steel Jeremias engineering uses its own software based upon the Chimney, Gas Vent, and Fireplace Systems chapter of the ASHRAE Handbook to assure that the exhaust and chimney system is sized in accordance with the appliance manufacturers installation instructions. 7

8 TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Pipe Weight per Foot The approximate installed weight of the DWKL exhaust system can be found using this table. This table does not include accessories such as supports and guides, nor shipping packaging or palletizing weight (LBS per foot). KL Paste KL Paste is a ceramic lubricating and assembly paste. The purpose is to help guide the pipe connections to assure the best steel to steel connection. It also seals the joint by allowing the ceramic to fill any microscopic steel imperfections. On fittings it will help the installer rotate to the correct position before tapping in place. Use 1 teaspoon of paste per 24 length of joint perimeter. Example: 10 inch diameter has 31 of perimeter length, so use about 1.3 teaspoons per each 10 inch joint connection. Below table allows for a 20% waste (About ½ wide smear). INSIDE DIAMETER DWKL, DWKL-Rx DWKL-Vt, DWKL-Lt 3 (76 mm) DNA 3.0 (4.4) 4 (102 mm) DNA 3.8 (5.7) 5 (127 mm) 5.3 (7.9) 4.4 (6.5) 6 (152 mm) 6.3 (9.3) 5.4 (8.0) 7 (178 mm) 7.2 (10.7) 6.1 (9.1) 8 (203 mm) 8.1 (12.1) 6.8 (10.1) 9 (229 mm) 9.1 (13.5) 7.6 (11.3) 10 (254 mm) 10.0 (14.9) 8.4 (12.5) 11 (249 mm) 10.9 (16.3) 9.1 (13.5) 12 (305 mm) 11.9 (17.7) 10.0 (14.9) 13 (330 mm) 12.8 (19.1) 10.7 (15.9) 14 (456 mm) 13.8 (20.5) 11.6 (17.3) 16 (406 mm) 15.6 (23.2) 13 (19.3) 18 (457 mm) 17.5 (26.0) 14.6 (21.7) 20 (508 mm) 19.4 (28.8) 16.2 (24.1) 22 (559 mm) 21.3 (31.6) 17.8 (26.5) 24 (610 mm) 23.1 (34.3) 19.2 (28.6) 26 (660mm) 23.7 (35.3) DNA 28 (711mm) 25.5 (37.9) DNA 30 (762mm) 27.2 (40.5) DNA 32 (812mm) 29.0 (43.2) DNA 34 (863mm) 30.7 (45.7) DNA 36 (914mm) 32.5 (48.4) DNA Table 1-1, No. (#) of Joints per 3.5 oz. Tube Ø # Submittal and Warranted Designs Jeremias also provides CAD layout designs that show all required accessories, including drains, supports, access panels, etc., to be in accordance with any specific appliance manufacturers installation instructions. QUICK & EASY INSTALLATION Clean the inner side of the female end and the outer side of the male end of each pipe. Apply the KL Paste to the female end. Use your hands to center both pipes in alignment. Connect both pipes and press them together as much as possible by hand. Use the wood plate (supplied with shipment) and place it on the end of the assembly. Tap 2-3 times. Make sure to press both inner and outer pipes together; the inner should not be more than 1/8 longer than the outer pipe once the male/female conical ends are engaged. Install and fix the Locking Band (LB). To ensure the connection is secure, the Locking Band must be perfectly fitted in both grooves. F inish NO SILICONE GASKET OR SEALANT USED (ONLY KL PASTE LUBRICANT)

9 ADAPTERS Raw Collar Adapter - Inside - Start / DWKLØ-RCIS Raw Collar Adapter - Inside - End / DWKLØ-RCIE Ø ØA ØB ØC Ø ØA ØB ØC Ø A Ø A Raw Collar Adapter - Outside - Start / DWKLØ-RCOS Raw Collar Adapter - Outside - End / DWKLØ-RCOE Ø ØA ØB 0.06 Thickness Ø ØA ØB 0.06 Thickness 9

10 ADAPTERS Flange Collar Adapter - Start / DWKLØ-FCS Ø ØA ØB ØC Flange Collar Adapter - End / DWKL-FCE Ø ØA ØB ØC ti/ta / Fan Plate Adapter - Start / DWKLØ-FPS Fan Plate Adapter - End / DWKLØ-FPE Ø ØA ØB ØC Ø ØA ØB ØC min Ø A + 3 min Ø A

11 ADAPTERS DWKL to SWKL Adapter / DWKLØ-D2S 125/150 Lb. ANSI Flange - Start / DWKLØ-AFS Ø ØA ØB ti/ta lb / Ø ØA ØB ØC ØD ØE n.holes Thickness 125/150 Lb. ANSI Flange - End / DWKLØ-AFE Ø ØA ØB ØC ØD ØE n.holes SWKL to DWKL Adapter / SWKLØ-S2D Ø ØA ØB t lb Thickness

12 SUPPORTS Anchor Support Plate / DWKLØ-APS Heavy Duty Base / DWKLØ-HDB Ø ØA ØB D Ø ØA ØB C B ØA+2.3 ØA+6 B ØA+2.3 ØA+6 B ØA+2.3 ØA+6 B + 6 B ØA+2.3 ØA ØA+2.3 ØA+6 B + 6 B + 6 B + 6 B Thickness ØA+2.3 ØA ØA+2.3 ØA ØA+2.3 ØA ØA+2.3 ØA Thickness B ØA+2.3 ØA+6 B ØA+2.3 ØA+6 B ØA+2.3 ØA+6 B ØA+2.3 ØA+6 B ØA+2.3 ØA+6 B ØA+2.3 ØA+6 B ØA+2.3 ØA+6 B ØA+2.3 ØA+6 B ØA+2.3 ØA+6 B ØA+2.3 ØA+6 B ØA+2.3 ØA+6 B ØA+2.3 ØA+6 B ØA+2.3 ØA+6 B ØA+2.3 ØA+6 Wall Brackets for Support / Ring / DWKLØ-WB Full Angle Ring / DWKLØ-FAR Ø A B Ø A ØA ØB ØC A+1/8 ØA+2.3 ØA A+1/8 ØA+2.3 ØA A+1/8 ØA+2.3 ØA A+1/8 ØA+2.3 ØA A+1/8 ØA+2.3 ØA A+1/8 ØA+2.3 ØA A+1/8 ØA+2.3 ØA A+1/8 ØA+2.3 ØA A+1/8 ØA+2.3 ØA A+1/8 ØA+2.3 ØA A+1/8 ØA+2.3 ØA Thickness A+1/8 ØA+2.3 ØA A+1/8 ØA+2.3 ØA A+1/8 ØA+2.3 ØA A+1/8 ØA+2.3 ØA A+1/8 ØA+2.3 ØA A+1/8 ØA+2.3 ØA A+1/8 ØA+2.3 ØA A+1/8 ØA+2.3 ØA A+1/8 ØA+2.3 ØA A+1/8 ØA+2.3 ØA A+1/8 ØA+2.3 ØA A+1/8 ØA+2.3 ØA +4 12

13 SUPPORTS Half Angle Ring / DWKLØ-HAR Light Support Band / DWKLØ-LSB Ø A ØA ØB ØC Ø ØA A+1/8 ØA+2.3 ØA A+1/8 ØA+2.3 ØA A+1/8 ØA+2.3 ØA Thickness A+1/8 ØA+2.3 ØA A+1/8 ØA+2.3 ØA A+1/8 ØA+2.3 ØA A+1/8 ØA+2.3 ØA A+1/8 ØA+2.3 ØA A+1/8 ØA+2.3 ØA A+1/8 ØA+2.3 ØA A+1/8 ØA+2.3 ØA A+1/8 ØA+2.3 ØA A+1/8 ØA+2.3 ØA A+1/8 ØA+2.3 ØA A+1/8 ØA+2.3 ØA A+1/8 ØA+2.3 ØA A+1/8 ØA+2.3 ØA A+1/8 ØA+2.3 ØA A+1/8 ØA+2.3 ØA A+1/8 ØA+2.3 ØA A+1/8 ØA+2.3 ØA A+1/8 ØA+2.3 ØA A+1/8 ØA+2.3 ØA Thickness Wire not included Guy Wires Band / DWKLØ-GWB Elbow 90 with support leg / DWKLØ-90ES Ø ØA Ø A B C D E Thickness For use with DWKLØSBP

14 SUPPORTS Support Base Plate / DWKLØSBP Ø B C

15 STRAIGHT LENGTHS 9 Fixed Length / DWKLØ-9L 12 Fixed Length / DWKLØ-12L Ø ØA ØB C D Ø ØA ØB C D Fixed Length / DWKLØ-18L 24 Fixed Length / DWKLØ-24L Ø ØA ØB C D Ø ØA ØB C D

16 STRAIGHT LENGTHS 30 Fixed Length / DWKLØ-30L 36 Fixed Length / DWKLØ-36L Ø ØA ØB C D Ø ØA ØB C D Fixed Length / DWKLØ-42L 48 Fixed Length / DWKLØ-48L Ø ØA ØB C D Ø ØA ØB C D

17 ADJUSTABLE LENGTHS 18 Adjustable Length / DWKLØ-18AL Ø ØA ØB - range 30 Adjustable Length / DWKLØ-30AL Ø ØA ØB - range 18 Adjustable Length w/gasket / DWKLØ-18AG Ø ØA ØB 30 Adjustable Length w/gasket / DWKLØ-30AG Ø ØA ØB - range (min - max) - (min - max) 17

18 ADJUSTABLE LENGTHS 18 Adjustable Length with Graphite Packing / DWKLØ-18ALG Ø ØA ØB - range (min - max) 30 Adjustable Length with Graphite Packing / DWKLØ-30ALG Ø ØA ØB - (min - max) 18 Cut Pipe Length / DWKLØ-18CL Ø ØA ØB - (min - max) Cut Pipe Length / DWKLØ-30CL Ø ØA ØB - (min - max) 18

19 ADJUSTABLE LENGTHS 18 Lined Bellows Length / DWKLØ-LBL Ø ØA ØB 19

20 ELBOWS 1.5 Elbow / DWKLØ-1.5EL Ø ØA ØB C D Elbow / DWKLØ-3EL Ø ØA ØB C D Elbow / DWKLØ-15EL Ø ØA ØB C D Elbow / DWKLØ-30EL Ø ØA ØB C D

21 ELBOWS 45 Elbow / DWKLØ-45EL Ø ØA ØB C D Elbow / DWKLØ-70EL Ø ØA ØB C D Elbow / DWKLØ-87EL Ø ØA ØB C D Elbow / DWKLØ-90EL Ø ØA ØB C D

22 ELBOWS 30 Elbow with/knock Plate / DWKLØ-30EK Ø ØA B C D E 45 Elbow with/knock Plate / DWKLØ-45EK Ø ØA B C D E F Elbow with/knock Plate / DWKLØ-70EK 87 Elbow with/knock Plate / DWKLØ-87EK Ø ØA B C D Ø A B C D

23 ELBOWS 90 Elbow with/knock Plate / DWKLØ-90EK Ø A B C Elbow 90 with support leg / DWKLØ-90ES Ø A B C D E

24 TEES 45 Tee / DWKLØ-45T 45 Reduction Tee / DWKLØ-45TØ Ø ØA ØB E F G H Ø ØA ØB ØC ØD E F G H I Customer Dimension Customer Dimension Customer Dimension Customer Dimension Customer Dimension Customer Dimension Customer Dimension Tee / DWKL-87T Ø ØA ØB C D E F 87 Reduction Tee / DWKLØ-87TØ Ø ØA ØB ØC ØD E F Customer Dimension 22.3 Costumer Dimension Costumer Dimension Customer Dimension

25 TEES 90 Tee / DWKLØ-90T Ø ØA ØB C D E 90 Reduction Tee / DWKLØ-90TØ Ø ØA ØB ØC ØD E Costumer Dimension Costumer Dimension Boot Tee / DWKLØ-87BT Ø ØA ØB C D E F G Boot Reduction Tee / DWKLØ-87BTØ Ø ØA ØB ØC ØD E F G Customer Dimension Customer Dimension Customer Dimension Customer Dimension Customer Dimension

26 TEES 90 Boot Tee / DWKLØ-90BT Ø ØA ØB ØC D E F G Boot Reduction Tee / DWKLØ-90BTØ Ø ØA ØB ØC ØD E F G H Customer Dimension Customer Dimension Customer Dimension Customer Dimension Customer Dimension Customer Dimension Double Tee / DWKLØ-45DT Ø ØA ØB ØC ØD E F G H I Customer Dimension Customer Dimension Customer Dimension Customer Dimension Customer Dimension Customer Dimension Customer Dimension 26

27 GREASE TEES 90 Grease Duct Tee / DWKLØ-90GT Ø ØA ØB C Grease Duct Tee / DWKLØ-87GT Ø ØA ØB C D E F Grease Duct Tee / DWKLØ-45GT Ø ØA ØB C D E F G Grease Duct Boot Tee / DWKLØ-90GBT Ø ØA ØB C D E F

28 GREASE TEES 87 Grease Duct Boot tee / DWKLØ-87GBT Ø ØA ØB C D E F G

29 WYE TEES 90 Wye Tee / DWKLØ-90WT 90 Reduction Wye Tee / DWKLØ-90WTØ Ø ØA ØB C D Ø ØA ØB 90 Reduction Wye Tee / DWKLØ-90WTØ Type 1 Ø ØC ØD E Reduction Wye Tee / DWKLØ-90WTØ Type 2 Ø ØC ØD E

30 WYE TEES 90 Reduction Wye Tee / DWKLØ-90WTØ Type 3 Ø ØC ØD E Reduction Wye Tee / DWKLØ-90WTØ Type 4 Ø ØC ØD E F

31 TEE CAPS Drain Tee Cap - Bottom / DWKLØ-DCB Drain Tee Cap - Side / DWKLØ-DCS Ø ØA ØB 1/2 N.P.T. Nipple Ø ØA ØB 1/2 N.P.T. Nipple Tee Cap Access / DWKLØ-TCA Ø ØA ØB 4,47 4,17 Grease Tee Cap Access / DWKLØ-GTCA Ø ØA ØB 31

32 INCREASERS Tapered Increaser / DWKLØ-TIØ Increase to next standard Ø Tapered Increaser / DWKLØ-TIØ Two standard Ø increase Ø ØA ØB ØC ØD E Ø ØA ØB ØC ØD E Tapered Increaser / DWKLØ-TIØ Three standard Ø increase Tapered Increaser / DWKLØ-TIØ Four standard Ø increase Ø ØA ØB ØC ØD E Ø ØA ØB ØC ØD E

33 INCREASERS Tapered Increaser / DWKLØ-TIØ Five standard Ø increase Tapered Eccentric Increaser / DWKLØ-TEIØ Ø ØA ØB ØC ØD E Ø ØA ØB E Tapered Eccentric Increaser / DWKLØ-TEIØ Increase to next standard Ø Tapered Eccentric Increaser / DWKLØ-TEIØ Two standard Ø increase Ø ØC ØD E Ø ØC ØD E

34 INCREASERS Tapered Eccentric Increaser / DWKLØ-TEIØ Three standard Ø increase Tapered Eccentric Increaser / DWKLØ-TEIØ Four standard Ø increase Ø ØC ØD E Ø ØC ØD E Tapered Eccentric Increaser / DWKLØ-TEIØ Five standard Ø increase Stepped Increaser / DWKLØ-SIØ Ø ØC ØD E Ø ØA ØB E

35 INCREASERS Stepped Increaser / DWKLØ-SIØ Increase to next standard Ø Stepped Increaser / DWKLØ-SIØ Two standard Ø Increase Ø ØC ØD E Ø ØC ØD E Stepped Increaser / DWKLØ-SIØ Three standard Ø Increase Stepped Increaser / DWKLØ-SIØ Four standard Ø Increase Ø ØC ØD E Ø ØC ØD E

36 INCREASERS Stepped Increaser / DWKLØ-SIØ Five standard Ø Increase Stepped Eccentric Increaser / DWKLØ-SEIØ Ø ØC ØD E Ø ØA ØB E Stepped Eccentric Increaser / DWKLØ-SEIØ Type 1 Stepped Eccentric Increaser / DWKLØ-SEIØ Type 2 Ø ØC ØD E Ø ØC ØD E

37 INCREASER Stepped Eccentric Increaser / DWKLØ-SEIØ Type 3 Stepped Eccentric Increaser / DWKLØ-SEIØ Type 4 Ø ØC ØD E Ø ØC ØD E Stepped Eccentric Increaser / DWKLØ-SEIØ Type 5 Ø ØC ØD E

38 REDUCERS Tapered Reducer / DWKLØ-TRØ Tapered Reducer / DWKLØ-TRØ Reduction to the next standard Ø Ø ØA ØB E Ø ØC ØD E Tapered Reducer / DWKLØ-TRØ Two standard Ø reduction Tapered Reducer / DWKLØ-TRØ Three standard Ø reduction Ø ØC ØD E Ø ØC ØD E

39 REDUCERS Tapered Reducer / DWKLØ-TRØ Four standard Ø reduction Tapered Reducer / DWKLØ-TRØ Five standard Ø reduction Ø ØC ØD E Ø ØC ØD E Tapered Eccentric Reducer / DWKLØ-TERØ Ø ØA ØB E 12.5 Tapered Eccentric Reducer / DWKLØ-TERØ Reduction to next standard Ø Ø ØC ØD E

40 REDUCERS Tapered Eccentric Reducer / DWKLØ-TERØ Two standard Ø reduction Ø ØC ØD E 12.5 Tapered Eccentric Reducer / DWKLØ-TERØ Three standard Ø reduction Ø ØC ØD E 12.5 Tapered Eccentric Reducer / DWKLØ-TERØ Four standard Ø reduction Ø ØC ØD E 12.5 Tapered Eccentric Reducer / DWKLØ-TERØ Five standard Ø reduction Ø ØC ØD E

41 REDUCERS Stepped Reducer / DWKLØ-SRØ Stepped Reducer / DWKLØ-SRØ Reduction to next standard Ø Ø ØA ØB E Ø ØC ØD E Stepped Reducer / DWKLØ-SRØ Two standard Ø reduction Stepped Reducer / DWKLØ-SRØ Three standard Ø reduction Ø ØC ØD E Ø ØC ØD E

42 REDUCERS Stepped Reducer / DWKLØ-SRØ Four standard Ø reduction Stepped Reducer / DWKLØ-SRØ Five standard Ø reduction Ø ØC ØD E Ø ØC ØD E Stepped Eccentric Reducer / DWKLØ-SERØ Stepped Eccentric Reducer / DWKLØ-SERØ Reduction to next standard Ø Ø ØA ØB E Ø ØA ØB E

43 REDUCERS Stepped Eccentric Reducer / DWKLØ-SERØ Two standard Ø reduction Stepped Eccentric Reducer / DWKLØ-SERØ Three standard Ø reduction Ø ØA ØB E Ø ØA ØB E Stepped Eccentric Reducer / DWKLØ-SERØ Four standard Ø reduction Stepped Eccentric Reducer / DWKLØ-SERØ Five standard Ø reduction Ø ØA ØB E Ø ØA ØB E

44 FLASHINGS Flat Roof Flashing / DWKLØ-FRF Ø ØA ØB ØC Pitched Roof Flashing / DWKLØ-PRF Ø ØA ØB ØC ß Customer Dimension Storm Collar / DWKLØ-SC Ø ØB ØC min distance Ventilated Roof Flashing / DWKL-VRF Ø ØA ØB

45 FLASHINGS Ventilated Storm Collar / DWKL-VSC Ø ØA ØB Flat Cone Flashing / DWKL-FCF Ø I.D ØB ØC Pitched Cone Flashing / DWKL-PCF Ø ØB ØC ØD ß Customer Dimension Storm Collar For Coned Flashings / DWKL-SCCF Ø ØA

46 FLASHINGS High Temperature Insulated Thimble / ØDWKL-HTT Ø ØA ØB ØC Low Temperature Thimble / DWKL-LTT Ø I.D ØA ØB ØC ØD ØE I.D I.D + 4 I.D I.D I.D

47 TERMINATIONS Transition to Round - Start / DWKLØ-TRS Ø ØA ØB ØC ØD Customer Dimension Customer Dimension Transition to Round - End / DWKLØ-TRE Ø ØA ØB C D Customer Dimension Customer Dimension Open Termination / DWKLØ-OTN Ø ØA ØB Open Termination High Temp / DWKLØ-OTNH Ø ØA ØB 47

48 TERMINATIONS Open Termination w/screen / DWKLØ-OTS Ø ØA ØB Open Termination w/screen High Temp / DWKLØ-OTSH Ø ØA ØB Exit Cone / DWKLØ-EC Ø ØA ØB C Exit Cone High Temp / DWKLØ-ECH Ø ØA ØB C

49 TERMINATIONS Flat Top Rain Cap / DWKLØ-FTN Ø ØA ØB C ØD Flat Top Rain Cap High Temp / DWKLØ-FTNH Ø ØA ØB C ØD Flat Top Rain Cap w/screen / DWKLØ-FTS Ø ØA ØB C ØD Flat Top Rain Cap w/screen High Temp / DWKLØ-FTSH Ø ØA ØB C ØD

50 TERMINATIONS High Wind Rain Cap / DWKLØ-WRC Ø ØA ØB ØC D E Stack Cap - no Screen / DWKLØ-SCN Ø ØA ØB C ØD Stack Cap - no Screen High Temperature / D-KLØ-SCNH Ø ØA ØB C ØD Stack Cap w/screen / DWKLØ-SCS Ø ØA ØB C ØD

51 TERMINATIONS Stack Cap w/screen High Temp / DWKLØ-SCSH Ø ØA ØB C ØD Miter Cut Termination w/screen / DWKLØ-MCS Ø ØA ØB Miter Cut Termination w/screen High Temp / DWKLØ-MCSH Ø ØA ØB Tee Termination w/screen / DWKLØ-TT Ø ØA ØB C

52 TERMINATIONS 90 Termination w/screen / DWKLØ-90ET Ø ØA ØB C Termination w/screen / DWKLØ-30ET Ø ØA ØB C D E Engine Flip Top / DWKLØ-EFT Ø ØA ØB Engine Flip Top High Temp / DWKLØ-EFTH Ø ØA ØB 52

53 TERMINATIONS No-Loss Weather Head / DWKLØ-NLWH Ø ØA ØB C D E F x x6 2x8 2x10 53

54 ACCESSORIES Locking Band / DWKLØ-LB Ø ØB Flange Collar Kit / DWKLØ-FCK Ø ØA ti/ta D.inner pipe Heat Shield for DWKL / HSDW Ø ØA ØB t Sq. In. Opening Standoffs Ø A Inline Access Door / DWKLØ-IAD Ø ØA ØB C D

55 ACCESSORIES Universal Drain Length / DWKLØ-UDL Ø ØA ØB Test and Nozzle Port Length / DWKLØ-TPL Ø ØA ØB 1/2 N.P.T. Nipple 1/2 N.P.T. Nipple SWKL Clamp / SWKL-KLC Balancing Baffle Length / ØDWKL-BBL Ø ØA Ø ØA ØB C D

56 ACCESSORIES Pressure Relief Valve ANSI Flange / DWKLØ-PRV Ø ØA ØB L Pressure Relive Valve with Rolled Flange / DWKLØ-PRVR Ø ØA ØB ØC L Flame Retardant Pressure Relive Valve / DWKLØ-PRVF Firestop Spacer / DWKLØ-FS Ø I.D ØA ØB t I.D

57 DWKL10-15EL DWKL10-30EL OFFSET TABLES OFFSET TABLES DWKLØ-15EL PART NUMBER DIM - A Ø DIM - B Ø DIM - C DIM - D DIM - E DIM - F INNER OUTER RISE RUN COMBINED HEIGHT COMBINED OFFSET DWKL3-15EL 3 5,5 4,5 3,2 14 1,85 DWKL4-15EL 4 6,5 4,7 3,3 14,26 1,88 DWKL5-15EL 5 7,5 4,77 3,56 14,52 1,91 DWKL6-15EL 6 8,5 4,83 3,78 14,78 1,94 DWKL7-15EL 7 9,5 4,9 3,97 15,04 1,97 DWKL8-15EL 8 10,5 4,96 4,16 15,3 2 DWKL9-15EL 9 11,5 5,03 4,36 15,56 2,03 DWKL10-15EL 10 12,5 5,09 4,55 15,82 2,06 DWKL11-15EL 11 13,5 5,16 4,74 16,08 2,09 DWKL12-15EL 12 14,5 5,23 4,94 16,34 2,12 DWKL13-15EL 13 15,5 5,29 5,13 16,6 2,15 DWKL14-15EL 14 16,5 5,35 5,32 16,86 2,18 DWKL16-15EL 16 18,5 5,42 5,71 17,38 2,24 DWKL18-15EL 18 20,5 5,56 6,09 17,9 2,3 DWKL20-15EL 20 22,5 5,59 6,48 18,42 2,36 DWKL22-15EL 22 24,5 5,82 6,87 18,94 2,42 DWKL24-15EL 24 26,5 5,95 7,25 19,46 2,48 DWKL26-15EL 26 28,5 6,21 7,64 19,98 2,56 DWKL28-15EL 28 30,5 6,35 8,02 20,5 2,6 DWKL30-15EL 30 32,5 6,48 8,41 21,02 2,66 DWKL32-15EL 32 34,5 6,61 8,8 21,54 2,72 DWKL34-15EL 34 36,5 6,74 9,18 22,06 2,78 DWKL36-15EL 36 38,5 6,84 9,57 22,58 2,84 E DWKL10-15EL F DWKLØ-15EL 2.20 DWKLØ-30EL PART NUMBER DIM - A Ø DIM - B Ø DIM - C DIM - D DIM - E DIM - F INNER OUTER RISE RUN COMBINED HEIGHT COMBINEDOFFSET DWKL3-30EL 3 5,5 5,08 2,8 14,69 3,94 DWKL4-30EL 4 6,5 5,22 2,93 15,19 4,07 DWKL5-30EL 5 7,5 5,35 3,07 15,69 4,2 DWKL6-30EL 6 8,5 5,48 3,2 16,19 4,34 DWKL7-30EL 7 9,5 5,62 3,33 16,69 4,47 DWKL8-30EL 8 10,5 5,75 3,47 17,19 4,61 DWKL9-30EL 9 11,5 5,89 3,6 17,69 4,74 DWKL10-30EL 10 12,5 6,02 3,74 18,19 4,87 DWKL11-30EL 11 13,5 4,7 4,01 18,69 5,01 DWKL12-30EL 12 14,5 6,29 4,2 19,19 5,14 DWKL13-30EL 13 15,5 4,7 4,23 19,69 5,27 DWKL14-30EL 14 16,5 6,56 4,27 20,19 5,41 DWKL16-30EL 16 18,5 6,82 4,51 21,19 5,68 DWKL18-30EL 18 20,5 7,09 4,81 22,19 5,95 DWKL20-30EL 20 22,5 7,36 5,07 23,19 6,21 DWKL22-30EL 22 24,5 7,63 5,34 24,19 6,48 DWKL24-30EL 24 26,5 7,9 5,61 25,19 6,75 DWKL26-30EL 26 28,5 8,16 5,88 26,19 7,02 DWKL28-30EL 28 30,5 8,43 6,14 27,19 7,29 DWKL30-30EL 30 32,5 8,7 6,41 28,19 7,56 DWKL32-30EL 32 34,5 8,97 6,68 29,19 7,83 DWKL34-30EL 34 36,5 9,24 6,95 30,19 8,1 DWKL36-30EL 36 38,5 9,5 7,22 31,19 8,37 E DWKL10-30EL DWKLØ-30EL F

58 DWKL10-90EL DWKL10-45EL OFFSET TABLES OFFSET TABLES DWKLØ-45EL PART NUMBER DIM - A Ø DIM - B Ø DIM - C DIM - D DIM - E DIM - F INNER OUTER RISE RUN COMBINED HEIGHT COMBINEDOFFSET DWKL3-45EL 3 5,5 5,49 3,21 14,81 6,33 DWKL4-45EL 4 6,5 5,7 3,41 15,52 6,43 DWKL5-45EL 5 7,5 5,91 3,62 16,27 6,67 DWKL6-45EL 6 8,5 6,11 3,83 16,93 7,01 DWKL7-45EL 7 9,5 6,32 4,04 17,64 7,4 DWKL8-45EL 8 10,5 6,53 4,24 18,35 7,6 DWKL9-45EL 9 11,5 6,74 4,45 19,05 7,89 DWKL10-45EL 10 12,5 6,94 4,66 19,76 8,18 DWKL11-45EL 11 13,5 7,01 4,98 20,78 8,73 DWKL12-45EL 12 14,5 7,07 5,36 21,17 8,77 DWKL13-45EL 13 15,5 7,35 5,41 21,8 9,07 DWKL14-45EL 14 16,5 7,77 5,49 22,59 9,36 DWKL16-45EL 16 18,5 8,18 5,9 24 9,94 DWKL18-45EL 18 20,5 8,6 6,31 25,42 10,53 DWKL20-45EL 20 22,5 9,01 6,73 26,83 11,11 DWKL22-45EL 22 24,5 9,43 7,14 28,24 11,7 DWKL24-45EL 24 26,5 9,84 7,56 29,66 12,29 DWKL26-45EL 26 28,5 10,33 7,97 31,08 12,88 DWKL28-45EL 28 30,5 10,75 8,38 32,5 13,47 DWKL30-45EL 30 32,5 11,16 8,8 33,92 14,06 DWKL32-45EL 32 34,5 11,58 9,21 25,34 14,65 DWKL34-45EL 34 36,5 11,99 9,63 26,76 15,24 DWKL36-45EL 36 38,5 12,41 10,04 28,18 15,83 E DWKL10-45EL DWKLØ-45EL F 2.20 DWKLØ-90EL PART NUMBER DIM - A Ø DIM - B Ø DIM - C DIM - D DIM - E DIM - F INNER OUTER RISE RUN COMBINED HEIGHT COMBINEDOFFSET DWKL3-90EL 3 5,5 8,25 5,96 14,21 14,21 DWKL4-90EL 4 6,5 8,75 6,46 15,21 15,21 DWKL5-90EL 5 7,5 9,25 6,96 16,21 16,21 DWKL6-90EL 6 8,5 9,75 7,46 17,21 17,21 DWKL7-90EL 7 9,5 10,25 7,96 18,21 18,21 DWKL8-90EL 8 10,5 10,75 8,45 19,21 19,21 DWKL9-90EL 9 11,5 11,25 8,96 20,21 20,21 DWKL10-90EL 10 12,5 11,75 9,46 21,21 21,21 DWKL11-90EL 11 13,5 12,25 9,96 22,21 22,21 DWKL12-90EL 12 14,5 12,75 10,46 23,21 23,21 DWKL13-90EL 13 15,5 13,25 10,96 24,21 24,21 DWKL14-90EL 14 16,5 13,75 11,46 25,21 25,21 DWKL16-90EL 16 18,5 14,75 12,46 27,21 27,21 DWKL18-90EL 18 20,5 15,75 13,46 29,21 29,21 DWKL20-90EL 20 22,5 16,75 14,46 31,21 31,21 DWKL22-90EL 22 24,5 17,75 15,46 33,21 33,21 DWKL24-90EL 24 26,5 18,75 16,46 35,21 35,21 DWKL26-90EL 26 28,5 19,75 17,46 37,21 37,21 DWKL28-90EL 28 30,5 20,75 18,46 39,21 39,21 DWKL30-90EL 30 32,5 21,75 19,46 41,21 41,21 DWKL32-90EL 32 34,5 22,75 20,46 43,21 43,21 DWKL34-90EL 34 36,5 23,75 21,46 45,21 45,21 DWKL36-90EL 36 38,5 24,75 22,46 47,21 47,21 E DWKL10-90EL F DWKLØ-90EL

59 SAMPLE SYSTEMS SAMPLE 1 DWKL ENGINE EXHAUST THREE (3) 14 I.D. / 16 ½ O.D. EXHAUST SYSTEMS ENGINE FLIP TOP HIGH TEMPERATURE, DWKL14-EFTH FULL ANGLE RING WITH DWKL-HDB, HEAVY DUTY BASE BELOW, DWKL14-FAR 48 PIPE LENGTHSOR COMBINATION OF SHORTER LENGTHS, DWKL14-48L 90 DEGREE ELBOW DWKL14 APS ANCHOR PLATE SUPPORT WITH DWKL14-HDB, HEAVY DUTY BASE BELOW, DWKL14-48L 48 PIPE LENGTHSOR COMBINATION OF SHORTER LENGTHS, DWKL14-48L 90 DEGREE ELBOW, DWKL14-90EL 18 LINED BELLOWS LENGTH, DWKL14-LBL FULL ANGLE RING WITH DWKL14-HDB, HEAVY DUTY BASE BESIDE, DWKL14-FAR FULL ANGLE RING WITH DWKL14-HDB, HEAVY DUTY BASE BESIDE, DWKL14-FAR ANCHOR PLATE SUPPORT WITH DWKL14-HDB, HEAVY DUTY BASE BELOW, DWKL14-APS 90 DEGREE BOOT TEE, DWKL14-90BT 18 LINED BELLOWS LENGTH, DWKL14-LBL FULL ANGLE RING WITH DWKL14-HDB, HEAVY DUTY BASE BESIDE, DWKL14-FAR ANSI FLANGE END, DWKL14-AFE DRAIN TEE CAP BOTTOM, DWKL14-DCB ANCHOR PLATE SUPPORT WITH DWKL14-HDB, HEAVY DUTY BASE, DWKL14 APS PRESSURE RELIEF VALVE, DWKL14-PRV 45 DEGREE TEE, DWKL14-45T ANSI FLANGE START, DWKL14-AFS 90 DEGREE ELBOW, DWKL14-EL90 18 LINED BELLOWS LENGTH, DWKL14-LBL WITH DWKL14-HDB BESIDE, DWKL14-FAR 125/150 LB. ANSI FLANGE START, DWKL14-AFS 59

60 SAMPLE SYSTEMS SAMPLE 2 DWKL BOILER STACK TWO (2) 16 I.D. INTO 20 I.D. / 22 ½ O.D. STACK ENGINE FLIP TOP HIGH TEMPERATURE, DWKL14-EFTH STORM COLLAR & DWKL20-FRF, FLAT ROOF FLASHING, DWKL20-SC 48 PIPE LENGTHS OR COMBINATION OF SHORTER LENGTHS, DWKL20-48L ANCHOR PLATE SUPPORT WITH DWKL20-WB, WALL BRACKET BENEATH, DWKL20-APS 90 DEGREE ELBOW, DWKL20-90EL ANCHOR PLATE SUPPORT, DWKL20-APS ADJ. LENGTH W/ GASKET, DWKL20-18AG ANCHOR PLATE, DWKL20-APS REDUCTION 90 DEGREE BOOT TEE, DWKL20-90BT:16 TEE CAP ACCESS, DWKL20-TCA ANCHOR PLATE SUPPORT, DWKL20-APS 90 DEG. BOOT TEE, DWKL20-90BT 90 DEGREE BOOT TEE, DWKL20-90BT:16 ANCHOR PLATE SUPPORT, DWKL20-APS DRAIN TEE CAP, DWKL20-DCB ADJ. LENGTH W/ GASKET, DWKL20-18AG ANCHOR PLATE SUPPORT, DWKL20-APS 90 DEGREE ELBOW, DWKL20-90EL 30 CUT LENGTH, DWKL16-30CL FLANGE COLLAR KIT, DWKL16-FCK 60

61 SAMPLE SYSTEMS SAMPLE 3 DWKL COMMERCIAL GREASE DUCT 2X 14, INTO 20, 1X 8, INTO COMMON 24 GREASE DUCT NO LOSS WEATHER HEAD, DWKL22-NLWH TRANSITION TO ROUND, DWKL22-TRS ANSI FLANGE END, DWKL24-AFE GREASE TEE CAP, DWKL24 GTCA GREASE BOOT TEE, DWKL24-90GBT STORM COLLAR, DWKL24-SC FLAT ROOF FLASHING, DWKL24-FRF HIGH TEMP INSULATED THIMBLE, DWKL24-HTT FULL ANGLE RING, DWKL24 FAR 48 PIPE LENGTH, DWKL24-48L 48 PIPE LENGTH, DWKL24-48L FULL ANGLE RING, DWKL24 FAR ANCHOR PLATE SUPPORT, DWKL24-APS 90 DEG ELBOW, DWKL24-90EL INLINE ACCESS DOOR, DWKL24-IAD 45 DEG TEE, DWKL24-45T:8 TAPERED ECC INCREASER, DWKL20-TEI:24 90 DEG ELBOW, DWKL20-90EL LIGHT SUPPORT BAND, DWKL20-LSB INLINE ACCESS DOOR, DWKL20-IAD ANCHOR PLATE SUPPORT, DWKL20-APS 90 DEGREE BOOT TEE, DWKL20-90BT:14 TAPERED ECC INCREASER, DWKL14-TEI:20 INLINE ACCESS DOOR, DWKL14-IAD 90 DEGREE ELBOW, DWKL14-90EL 90 DEG ELBOW & DWKL8-IAD, INLINE ACCESS DOOR, DWKL8-90EL 18 CUT LENGTH, DWKL14-CL18 TRANSITION TO ROUND, DWKL14-TRS LIGHT SUPPORT BAND, DWKL8-LSB LIGHT SUPPORT BAND, DWKL8-LSB LIGHT SUPPORT BAND, DWKL8-LSB 90 DEG ELBOW, DWKL8-90EL 61

62 SAMPLE SYSTEMS SAMPLE 4 DWKL PIZZA OVEN CHIMNEY & GREASE DUCT 10 I.D. / 12½ O.D. CHIMNEY AND GREASE DUCT FAN ADAPTER END, DWKL10-FPE STORM COLLAR, DWKL10-SC FLAT ROOF FLASHING, DWKL-10-FRF HIGH TEMP INSULATED THIMBLE, DWKL10-HTT 48 PIPE LENGTH, DWKL10-48L ANCHOR PLATE SUPPORT, DWKL10-APS 36 PIPE LENGTH, DWKL10-36L LIGHT SUPPORT BAND, DWKL10-LSB 90 DEG TEE, DWKL10-90T GREASE TEE CAP ACCESS, DWKL10-GTCA ANCHOR PLATE SUPPORT, DWKL10-APS 90 DEG ELBOW, DWKL10-90EL 48 PIPE LENGTH, DWKL10-48L FLANGE COLLAR ADAPTER, DWKL10-FCS GREASE TEE CAP ACCESS, DWKL10-GTCA 90 DEG GREASE TEE, DWKL10-90GT 62

63 SAMPLE SYSTEMS SAMPLE 5 DWKL STAND-ALONE RESTAURANT EXHAUST 9 I.D. / 11½ O.D. GREASE DUCT FROM WALL MOUNTED TYPE I HOOD GREASE TEE CAP, DWKL24 GTCA GREASE TEE CAP, DWKL24 GTCA GREASE TEE CAP, DWKL24 GTCA 48 PIPE LENGTH, DWKL9-48L ANCHOR PLATE SUPPORT, DWKL9-APS 87 DEGREE ELBOW, DWKL9-87EL INLINE ACCESS DOOR, DWKL9-IAD 36 PIPE LENGTH, DWKL9-36L 30 CUT LENGTH, DWKL9-30CL 87 DEGREE ELBOW, DWKL9-87EL INLINE ACCESS DOOR, DWKL9-IAD 36 PIPE LENGTH, DWKL9-36L FLANGE COLLAR START, DWKL8-FCS 63

HPE. High Pressure Exhaust. Submittal Record. Models DWKL and SWKL. DWKL Double Wall SWKL Single Wall

HPE. High Pressure Exhaust. Submittal Record. Models DWKL and SWKL. DWKL Double Wall SWKL Single Wall Engine Exhaust Boiler Breeching/Stack Fume Venting Fireplace Chimney HPE High Pressure Exhaust Models DWKL and SWKL Submittal Record DWKL Double Wall SWKL Single Wall PROJECT: PREPARED BY: PREPARED FOR:

More information

venting systems for high efficiency appliances series

venting systems for high efficiency appliances series venting systems for high efficiency appliances series LISTINGS The Schebler event and event PLUS system are tested and listed by Underwriters Laboratories Inc. (UL) under file number MH10056 for UL 1738

More information

Models PS/IPS. Stainless Steel Double Wall Positive Pressure Piping Systems FEATURES CATALOG

Models PS/IPS. Stainless Steel Double Wall Positive Pressure Piping Systems FEATURES CATALOG CATALOG Models PS/IPS Stainless Steel Double Wall Positive Pressure Piping Systems Selkirk Commercial & Industrial Models PS and IPS are modular, prefabricated piping systems which embody flanged joints

More information

SELKIRK CORP INSTALLATION INSTRUCTION SUPPLEMENT MODEL G - CHIMNEY LINER

SELKIRK CORP INSTALLATION INSTRUCTION SUPPLEMENT MODEL G - CHIMNEY LINER SELKIRK CORP MODEL G - CHIMNEY LINER These instructions are supplemental to the General Installation Instructions for Selkirk Model G, PS, IPS and ZC Single Wall, Double Wall Air & Fiber Insulated Positive

More information

Technical and Dimensional Data. Double Wall One Inch Air Space AL 29-4C Stainless Steel Special Gas Vent

Technical and Dimensional Data. Double Wall One Inch Air Space AL 29-4C Stainless Steel Special Gas Vent $5 Technical and Dimensional Data Saf-T Vent CI Plus Double Wall One Inch Air Space AL 29-4C Stainless Steel Special Gas Vent For Venting Commercial & Industrial Appliances Condensing Appliances Category

More information

Model N. Stainless Steel Double Wall Positive Pressure Venting Systems. Special Gas Vent Applications COMMERCIAL AND INDUSTRIAL VENTING

Model N. Stainless Steel Double Wall Positive Pressure Venting Systems. Special Gas Vent Applications COMMERCIAL AND INDUSTRIAL VENTING COMMERCIL ND INDUSTRIL VENTING Model N Stainless Steel Double Wall Positive Pressure Venting Systems Special Gas Vent pplications Model N is a single wall negative, neutral, or positive pressure pre-fabricated

More information

Model VSI-I & VSI-II Positive Pressure Venting Systems

Model VSI-I & VSI-II Positive Pressure Venting Systems C O M M E R C I A L A N D I N D U S T R I A L V E N T I N G Model VSI-I & VSI-II Positive Pressure Venting Systems Ideal for discharging exhaust gases and fumes from boilers, heaters, ovens, engines, turbines

More information

Model DW Series Positive Pressure Guidelines for Engine Exhaust Systems

Model DW Series Positive Pressure Guidelines for Engine Exhaust Systems Model DW Series Positive Pressure Guidelines for Engine Exhaust Systems UL Listed Under: UL 103 / ULC ORD C959 UL 2561 / ULC ORD C959 UL 641 / ULC S609 1 Please note these instructions cover the additional

More information

Saf-T Vent EZ Seal. Technical and Dimensional Data. Single Wall AL 29-4C Stainless Steel Special Gas Vent

Saf-T Vent EZ Seal. Technical and Dimensional Data. Single Wall AL 29-4C Stainless Steel Special Gas Vent Technical and Dimensional Data Saf-T Vent EZ Seal Single Wall AL 29-4C Stainless Steel Special Gas Vent 130 Industrial Boulevard Turners Falls, MA 01376 Copyright 2001 Heat-fab, Incorporated Saf-T Vent

More information

Model DW Series Positive Pressure Guidelines for Engine Exhaust Systems

Model DW Series Positive Pressure Guidelines for Engine Exhaust Systems 1 Model DW Series Positive Pressure Guidelines for Engine Exhaust Systems UL Listed under Standard 103 for Flue Gas Temperatures up to 1400 F (759 C) Venting System for Factory-Built Chimneys For Building

More information

DuraChimney II. Air-cooled chimney system for masonry fireplaces. UL 103.

DuraChimney II. Air-cooled chimney system for masonry fireplaces. UL 103. DuraChimney II Air-cooled chimney system for masonry fireplaces. UL 103. Specifications Applications DuraChimney II is a double-wall, air-cooled chimney system for use with masonry fireplaces which burn

More information

InoxSabiana 50 Flues Stainless Steel Double Wall ENVIRONMENTAL COMFORT

InoxSabiana 50 Flues Stainless Steel Double Wall ENVIRONMENTAL COMFORT Flues Stainless Steel Double Wall ISO 9001 - Cert. n 0545/4 Unit heaters Radiant panels Fan coils Air handling units Flues ENVIRONMENTAL COMFORT Introduction and main constructional characteristics Double

More information

RECTANGULAR, 2-HOUR FIRE RATED, ZERO-CLEARANCE GREASE DUCT CO.

RECTANGULAR, 2-HOUR FIRE RATED, ZERO-CLEARANCE GREASE DUCT CO. RECTANGULAR, 2-HOUR FIRE RATED, ZERO-CLEARANCE GREASE DUCT CO. For over 75 years, Van-Packer has supplied venting products to the Commercial and Industrial heating and process markets. For the past 30

More information

Gas Venting Systems residential industrial commercial

Gas Venting Systems residential industrial commercial Gas Venting Systems residential industrial commercial AirJet Gas Vent AirJet Gas Vent is listed by Underwriters Laboratories, Standard UL-441, and accepted by FHA, VA, BOCA, ICBO and SBCted by Underwriters

More information

INSTALLATION AND MAINTENANCE INSTRUCTIONS

INSTALLATION AND MAINTENANCE INSTRUCTIONS INSTALLATION AND MAINTENANCE INSTRUCTIONS MODEL IPIC GREASE DUCT AND CHIMNEY IPIC This symbol on the nameplate means this product is listed by Underwriters Laboratories Inc. and by Underwriters Laboratories

More information

MODEL P1. Chimney and Exhaust Systems. Underwriters c. Laboratories Inc. LISTED

MODEL P1. Chimney and Exhaust Systems. Underwriters c. Laboratories Inc. LISTED MODEL P1 Chimney and Exhaust Systems UL UL Underwriters c Laboratories Inc. LISTED LISTINGS The Schebler Model P1 chimney and exhaust system is listed by Underwriters Laboratories Inc. (UL) under file

More information

MODEL P4. Chimney and Exhaust Systems. Underwriters c. Laboratories Inc. LISTED

MODEL P4. Chimney and Exhaust Systems. Underwriters c. Laboratories Inc. LISTED MODEL P4 Chimney and Exhaust Systems UL UL Underwriters c Laboratories Inc. LISTED LISTINGS The Schebler Model P4 chimney and exhaust system is listed by Underwriters Laboratories Inc. (UL) under file

More information

Modular Double-Wall Positive Pressure Chimney Boiler Breeching & Stack and Engine Exhaust Grease Duct

Modular Double-Wall Positive Pressure Chimney Boiler Breeching & Stack and Engine Exhaust Grease Duct Modular Double-Wall Positive Pressure himney oiler reeching & Stack and Engine Exhaust Grease Duct DuraStack Pro Modular Double-Wall Positive Pressure himney oiler reeching & Stack and Engine Exhaust DuraStack

More information

MODEL P2A. Chimney and Exhaust Systems. Underwriters c. Laboratories Inc. LISTED

MODEL P2A. Chimney and Exhaust Systems. Underwriters c. Laboratories Inc. LISTED MODEL P2 Chimney and Exhaust Systems UL UL Underwriters c Laboratories Inc. LISTED LISTINGS The Schebler Model P2 chimney and exhaust system is listed by Underwriters Laboratories Inc. (UL) under file

More information

Saf-T Vent EZ Seal. Technical and Dimensional Data. Single Wall AL 29-4C Stainless Steel Special Gas Vent

Saf-T Vent EZ Seal. Technical and Dimensional Data. Single Wall AL 29-4C Stainless Steel Special Gas Vent Technical and Dimensional Data Saf-T Vent EZ Seal Single Wall L 29-4 Stainless Steel Special Gas Vent Tested and Listed to UL 1738/UL S636 by Underwriters Laboratories, Inc 5030 orporate Exchange lvd Grand

More information

Saf-T Vent EZ Seal. Technical and Dimensional Data. Single Wall AL 29-4C Stainless Steel Special Gas Vent

Saf-T Vent EZ Seal. Technical and Dimensional Data. Single Wall AL 29-4C Stainless Steel Special Gas Vent Technical and Dimensional Data Saf-T Vent EZ Seal Single Wall L 29-4 Stainless Steel Special Gas Vent Tested and Listed to UL 1738/UL S636 by Underwriters Laboratories, Inc 5030 orporate Exchange lvd Grand

More information

venting systems for high efficiency appliances series

venting systems for high efficiency appliances series venting systems for high efficiency appliances series SUPERIOR SYSTEM DESIGN event DualSeal with RapidLock Connection System is a modular double wall prefabricated vent and exhaust systems used in venting

More information

Versatility in Applications

Versatility in Applications Versatility in Applications For over 60 years, Van-Packer has been supplying the Commercial and Industrial market with venting products. From our Model DW (Double Wall Stainless Steel) to Refractory Lined,

More information

MODEL PA. Chimney and Exhaust Systems. Underwriters c. Laboratories Inc. LISTED

MODEL PA. Chimney and Exhaust Systems. Underwriters c. Laboratories Inc. LISTED MODEL P Chimney and Exhaust Systems UL UL Underwriters c Laboratories Inc. LISTED LISTINGS The Schebler Model P chimney and exhaust system is listed by Underwriters Laboratories Inc. (UL) under file number

More information

INSTALLATION INSTRUCTIONS K SERIES LINER INSERT

INSTALLATION INSTRUCTIONS K SERIES LINER INSERT Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS K SERIES LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

INSTALLATION AND MAINTENANCE INSTRUCTIONS

INSTALLATION AND MAINTENANCE INSTRUCTIONS INSTALLATION AND MAINTENANCE INSTRUCTIONS MODEL PIC/IPIC CHIMNEY AND VENTS PIC IPIC This symbol on the nameplate means this product is listed by Underwriters Laboratories Inc. and by Underwriters Laboratories

More information

Saf-T Vent EZ Seal. Technical and Dimensional Data. Single Wall AL 29-4C Stainless Steel Special Gas Vent

Saf-T Vent EZ Seal. Technical and Dimensional Data. Single Wall AL 29-4C Stainless Steel Special Gas Vent Technical and Dimensional Data Saf-T Vent EZ Seal Single Wall L 29-4 Stainless Steel Special Gas Vent Tested and Listed to UL 1738/UL S636 by Underwriters Laboratories, Inc opyright 2008 Selkirk orp. Saf-T

More information

INSTALLATION INSTRUCTIONS UNDER CABINET HOOD

INSTALLATION INSTRUCTIONS UNDER CABINET HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS UNDER CABINET HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

Series. Chimney System for High Efficiency Appliances. Underwriters c. Laboratories Inc. LISTED

Series. Chimney System for High Efficiency Appliances. Underwriters c. Laboratories Inc. LISTED Series Chimney System for High Efficiency ppliances UL UL Underwriters c Laboratories Inc. LISTED LISTINGS The Schebler event and eventplus system are tested and listed by Underwriters Laboratories Inc.

More information

Our mission is to become the supplier of choice for gas venting products and solutions.

Our mission is to become the supplier of choice for gas venting products and solutions. Our mission is to become the supplier of choice for gas venting products and solutions. Company Profile Cheminée Lining started out as a sales company that provided customers with quality products and

More information

INSTALLATION INSTRUCTIONS UNDER CABINET HOOD

INSTALLATION INSTRUCTIONS UNDER CABINET HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS UNDER CABINET HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

INSTALLATION INSTRUCTIONS K-SERIES UNDER CABINET HOOD

INSTALLATION INSTRUCTIONS K-SERIES UNDER CABINET HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS K-SERIES UNDER CABINET HOOD Read All Instructions Thoroughly Before Beginning Installation

More information

INSTALLATION INSTRUCTIONS ISLAND LINER INSERT

INSTALLATION INSTRUCTIONS ISLAND LINER INSERT Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS ISLAND LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO ISLAND RANGE HOOD

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO ISLAND RANGE HOOD WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK C U L R Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO

More information

VENTING & COMBUSTION AIR GUIDE

VENTING & COMBUSTION AIR GUIDE PRE-INSTALLATION APPLICATION GUIDE VENTING & COMBUSTION AIR GUIDE Natural Gas, Propane and Dual Fuel Modulating and Condensing BOILER BODY VENT STARTER SECTION APPLIES TO MODELS: BMK 750 BMK 1000 BMK 1500

More information

RECEIVING AND INSPECTION EXAMINE ALL COMPONENTS FOR POSSIBLE SHIPPING DAMAGE PRIOR TO INSTALLATION.

RECEIVING AND INSPECTION EXAMINE ALL COMPONENTS FOR POSSIBLE SHIPPING DAMAGE PRIOR TO INSTALLATION. Non-Welded Grease Duct Systems Installation, Operation, and Maintenance Manual FOR YOUR SAFETY TWO MAJOR CAUSES OF GREASE DUCT RELATED FIRES: (1) FAILURE TO MAINTAIN REQUIRED CLEARANCE (AIR SPACE) TO COMBUSTIBLE

More information

INSTALLATION INSTRUCTIONS CWUH9 WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS CWUH9 WALL MOUNT HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS CWUH9 WALL MOUNT HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

INSTALLATION INSTRUCTIONS JCH/C2 DESIGNER SERIES WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS JCH/C2 DESIGNER SERIES WALL MOUNT HOOD WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK C U L R Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS JCH/C2 DESIGNER SERIES

More information

INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD WITH M600 OR M1200 BLOWER

INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD WITH M600 OR M1200 BLOWER WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK C U L R Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD

More information

INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD WITH M600 OR M1200 BLOWER

INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD WITH M600 OR M1200 BLOWER WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK C U L R Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD

More information

INSTALLATION INSTRUCTIONS ZTH WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS ZTH WALL MOUNT HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS ZTH WALL MOUNT HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

PRE-INSTALLATION VENTING AND COMBUSTION AIR DESIGN GUIDE

PRE-INSTALLATION VENTING AND COMBUSTION AIR DESIGN GUIDE Benchmark Series GF-2050 PRE-INSTALLATION VENTING AND COMBUSTION AIR DESIGN GUIDE Natural Gas, Propane Gas, or Dual Fuel Fired Modulating, Condensing BENCHMARK & Benchmark Platinum Gas-Fired This document

More information

INSTALLATION INSTRUCTIONS WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS WALL MOUNT HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING -

More information

Model RIS ALL FUEL, INSULATED CHIMNEY SYSTEM 10" - 24"

Model RIS ALL FUEL, INSULATED CHIMNEY SYSTEM 10 - 24 ALL FUEL, INSULATED CHIMNEY SYSTEM 10" - 24" 42 Technical Information Technical Information Certification is tested and listed by Intertek Testing Services to the following standard: UL 103HT - The standard

More information

Installation Instructions

Installation Instructions Installation Instructions Models: SLP Venting System These venting system components have been tested for use with approved HHT Direct Vent appliances. Check with your local building code agency before

More information

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK C U L R Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO

More information

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK C U L R Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO

More information

INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD

INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

RECEIVING AND INSPECTION

RECEIVING AND INSPECTION Non-Welded Grease Duct Systems Installation, Operation, and Maintenance Manual FOR YOUR SAFETY TWO MAJOR CAUSES OF GREASE DUCT RELATED FIRES: (1) FAILURE TO MAINTAIN REQUIRED CLEARANCE (AIR SPACE) TO COMBUSTIBLE

More information

INSTALLATION INSTRUCTIONS JDH/C2 DESIGNER SERIES WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS JDH/C2 DESIGNER SERIES WALL MOUNT HOOD WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK C U L R Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS JDH/C2 DESIGNER SERIES

More information

INSTALLATION INSTRUCTIONS CWEH6-K WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS CWEH6-K WALL MOUNT HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS CWEH6-K WALL MOUNT HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

All-Fuel Chimney Systems

All-Fuel Chimney Systems U.S. TECHNICAL DOCUMENTS Example: Fireplace Opening 42 W by H Chimney Height 12 Use 14 Diameter 36 42 4 FIREPLACE OPENING HEIGHT, in.,h The Selkirk All-Fuel 24 Chimney system includes a variety of components

More information

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD Read All Instructions Thoroughly Before Beginning Installation

More information

SIGRAM FLUE SYSTEMS LTD

SIGRAM FLUE SYSTEMS LTD SIGRAM FLUE SYSTEMS LTD TEL: 0161 320 1999 FAX: 0161 320 6515 E-MAIL: sales@sigram.co.uk WEB: www.sigram.co.uk FLUE SYSTEMS FOR INDUSTRIAL & COMMERCIAL APPLICATIONS SINCE 1969 PROJECT WORK SITE SURVEY

More information

INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD

INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

VENT FLASHINGS GALVANIZED STEEL

VENT FLASHINGS GALVANIZED STEEL FLASHINGS C = CARDED STANDARD ALL-PITCH PLUMBING & ELECTRICAL FLASHING 34-0010 B 1/2 F 1/2 Steel pipe 7/8 I.D. 12 34-0014 B 3/4 F 3/4 Steel pipe 1-1/8 I.D. 12 34-0018 B 1 F 1 Steel pipe or DWV 1-3/8 I.D.

More information

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO ISLAND RANGE HOOD

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO ISLAND RANGE HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO ISLAND RANGE HOOD Read All Instructions Thoroughly Before Beginning

More information

Table of Contents WARRANTY...3 APPLICATION...4 MECHANICAL...5 Joint Sealant...5 Grease Duct Standard Connection...6 Collar and Adjustable Duct

Table of Contents WARRANTY...3 APPLICATION...4 MECHANICAL...5 Joint Sealant...5 Grease Duct Standard Connection...6 Collar and Adjustable Duct Non-Welded Grease Duct Systems Installation, Operation, and Maintenance Manual FOR YOUR SAFETY TWO MAJOR CAUSES OF GREASE DUCT RELATED FIRES: () FAILURE TO MAINTAIN REQUIRED CLEARANCE (AIR SPACE) TO COMBUSTIBLE

More information

INSTALLATION INSTRUCTIONS CWSH3 WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS CWSH3 WALL MOUNT HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS CWSH3 WALL MOUNT HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

INSTALLATION INSTRUCTIONS CWEH6-K WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS CWEH6-K WALL MOUNT HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS CWEH6-K WALL MOUNT HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

Technical and Dimensional Data. Double Wall AL 29-4C Stainless Steel Special Gas Vent and Type L Vent

Technical and Dimensional Data. Double Wall AL 29-4C Stainless Steel Special Gas Vent and Type L Vent Technical and Dimensional Data Saf-T Vent I Plus Double Wall L 29-4 Stainless Steel Special Gas Vent and Type L Vent For Venting ommercial & Industrial ppliances ondensing ppliances ategory I,II,III,IV

More information

PennBarry Fan Guide Specification. Laboratory Exhaust System: Model vplume

PennBarry Fan Guide Specification. Laboratory Exhaust System: Model vplume PennBarry Fan Guide Specification Laboratory Exhaust System: Model vplume This document 2018 PennBarry vplume is a commercial lab exhaust fan that ensures a greater margin of safety by effectively dispersing

More information

NEW All Biomass Chimney components are available in matte black. Just add "B" to the end of the part numbers you are ordering.

NEW All Biomass Chimney components are available in matte black. Just add B to the end of the part numbers you are ordering. Type L iomass himney For use with biomass fuels such as pellet, corn, wheat or other grassy and woody plants as specified by appliance manufacturers. Tested and Listed to UL641 Pipe and fittings in 3 and

More information

PRODUCT INDEX PRODUCT INDEX. Item Page Item Page Item Page

PRODUCT INDEX PRODUCT INDEX. Item Page Item Page Item Page PRODUCT CATALOG PRODUCT INDEX Item Page Item Page Item Page PRODUCT INDEX 001 Flat 45 Duct Angle 11 002 Flat 90 Duct Elbow 11 003 Vertical 45 Duct Angle 11 004 Vertical 90 Duct Elbow 11 005 Duct End Cap

More information

Accessory Catalog 2017 Revision: M-ACCS July 2017

Accessory Catalog 2017 Revision: M-ACCS July 2017 www.maximsilencers.com Industrial Silencer, Heat Recovery and Catalytic Specialists Maxim Silencers Accessory Catalog 2017 July 2017 Prices are subject to change without notice. Prices are in U.S. dollars

More information

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK CENTRIFUGAL UPBLAST ROOF EXHAUSTERS COMMERCIAL KITCHEN APPLICATIONS Belt Driven Model VRBK DESIGNED AND ENGINEERED TO MEET INDUSTRY NEEDS The Carnes Company

More information

XIII. Repair Parts 106

XIII. Repair Parts 106 XIII. Repair Parts All Alpine Repair Parts may be obtained through your local authorized U.S. Boiler Company representatives or outlets. Should you require assistance in locating a U.S. Boiler Company

More information

ACCESSORIES. Adaptor for ex100 spin-on ex100 UL/ULC Spin-on filter complete 10 µm, 17 gph UL/ULC Spin-on element 10micron for EX200 UL/ULC

ACCESSORIES. Adaptor for ex100 spin-on ex100 UL/ULC Spin-on filter complete 10 µm, 17 gph UL/ULC Spin-on element 10micron for EX200 UL/ULC ACCESSORIES SPIN-ON FILTER: 10 MICRON, 17 GPH WITH NPT PIPE CONNECTIONS (40 PSI MAX) The spin-on filter helps to increase your heating system s efficiency and to protect your furnace s burner. The element

More information

PA S SI ONAT E COLLABORATIVE INNOVATIVE EMPOWERED. GT Exhaust and Silex Innovations are divisions of Nelson Global Products

PA S SI ONAT E COLLABORATIVE INNOVATIVE EMPOWERED. GT Exhaust and Silex Innovations are divisions of Nelson Global Products PA S SI ONAT E COLLABORATIVE INNOVATIVE T R U S T E D EMPOWERED EN E R G IZ E D A C C E S S O R Y C ATA L O G & S P E C I F I C AT I O N S GT Exhaust and Silex Innovations are divisions of Nelson Global

More information

HIGH CAPACITY POWER VENT KIT

HIGH CAPACITY POWER VENT KIT IMPORTANT: THESE INSTRUCTIONS ARE TO REMAIN WITH THE APPLIANCE INSTRUCTIONS These instructions are supplementary to the Installation and Operating Instructions supplied with the fi replace and should be

More information

Global Finishing Solutions Table of Contents

Global Finishing Solutions Table of Contents Global Finishing Solutions Table of Contents Spray Booths-Accessories ProClean - Open Face Filter Booths... 2 ProClean Extensions... 3 Redi-Pak TM - Bench Booths... 4 Ultra and Concept Paint Mix Rooms...

More information

Pumpsaver. Form Follows Function. W A R R A N T Y. Standard Sizes

Pumpsaver. Form Follows Function. W A R R A N T Y. Standard Sizes NEW! Pumpsaver Form Follows Function. Many believe that all braided pump connectors are the same, until you go to pick up the Pumpsaver. The Pumpsaver is manufactured with closed pitch hose making it an

More information

Aim higher. Soil & Waste System

Aim higher. Soil & Waste System Aim higher Soil & Waste System Driven by durability FACT Trend towards prefabrication In most countries the labour costs are becoming an increasing part of the total installed cost of a project. To keep

More information

Large Diameter Chimney System

Large Diameter Chimney System CATALOG Large Diameter Chimney System The Selkirk Large Diameter Chimney is a perfect fit for large custom masonry fireplaces. Selkirk offers the best selection of large diameter chimney pipe in the industry:

More information

KVR Capture Jet. KVR- Capture Jet Round Island Hood with Perimeter Jets. Round Island Hood with Perimeter Jets

KVR Capture Jet. KVR- Capture Jet Round Island Hood with Perimeter Jets. Round Island Hood with Perimeter Jets KVR Capture Jet Round Island Hood with Perimeter Jets The KVR Round Island Capture Jet hood with perimeter jets is a highly efficient kitchen ventilation hood that removes contaminated air and excess heat

More information

Good Enough Never Is. Plug Fan SERIES 12

Good Enough Never Is. Plug Fan SERIES 12 Plug Fan SERIES 12 Good Enough Never Is The Hartzell Difference Combine Hartzell QUALITY with your PRODUCT for a BETTER CHOICE for your customers! GOOD ENOUGH NEVER IS. Hartzell Air Movement is the industrial

More information

Item No. Item Description In Stock

Item No. Item Description In Stock Item No. Item Description In Stock Whse: AZFS 3PVP-06 3 X 6 STRAIGHT LENGTH PIPE 8 3PVP-12 3 X 12 STRAIGHT LENGTH PIPE 9 3PVP-12A 3 X 12ADJUSTABLE LENGTH PIPE 6 3PVP-18A 3 X 18 ADJUSTABLE LENGTH PIPE 11

More information

Ventinox kits. Ventinox VFT Kit without Tee. Ventinox VFT Kit with Tee. Ventinox VFT Extensions. Flexible Relining Ventinox

Ventinox kits. Ventinox VFT Kit without Tee. Ventinox VFT Kit with Tee. Ventinox VFT Extensions. Flexible Relining Ventinox Flexible Relining Ventinox Ventinox kits Ventinox Kit without Tee Includes Ventinox Liner, Top Plate, and Rain Cap with Storm Collar. Choose diameter and length needed. SIZE LENGTH 3 25-3K25 316013 4 25-4K25

More information

Viking Installation Guide

Viking Installation Guide Viking Installation Guide Viking Range Corporation 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 For product information, call 1-888-VIKING1 (845-4641) or visit the Viking Web site at

More information

YOUR FULL LINE SOURCE FOR PVC ELECTRICAL PRODUCT

YOUR FULL LINE SOURCE FOR PVC ELECTRICAL PRODUCT CANTEX INC. 301 Commerce Ste 2700 Fort Worth, Texas 76102 817-215-7000 Fax: 817-215-7001 Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes YOUR FULL

More information

Item No. Item Description In Stock

Item No. Item Description In Stock Item No. Item Description In Stock Whse: AZFS 3PVP-06 3 X 6 STRAIGHT LENGTH PIPE 8 3PVP-12 3 X 12 STRAIGHT LENGTH PIPE 9 3PVP-12A 3 X 12ADJUSTABLE LENGTH PIPE 6 3PVP-18A 3 X 18 ADJUSTABLE LENGTH PIPE 11

More information

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER MODEL TUB MODEL FEATURES Exhaust air up to 60,116 CFM in static pressure applications up to 1 w.g. Straight-through air flow design results in maximum exhaust efficiency Motor and drives are located outside

More information

M K. MK is a pressurized steel boiler for heating system with hot water production up 90 C. High efficiency

M K. MK is a pressurized steel boiler for heating system with hot water production up 90 C. High efficiency M K MK is a pressurized steel boiler for heating system with hot water production up 90 C. High efficiency Gas/ gas oil working Output from 44 to 291,7 (from 37.840 to 250.862 of water efficiency). Pipe

More information

Vertical Balanced Flue Kit All Internal Grant Boilers

Vertical Balanced Flue Kit All Internal Grant Boilers GENERAL Flue sections cannot be cut. Part No. DOC30 REV04 October 2008 SUPPLEMENTARY INSTALLATION INSTRUCTIONS Vertical Balanced Flue Kit All Internal Grant Boilers THIS SUPPLEMENT SHOULD BE READ IN CONJUNCTION

More information

ESR ICC Evaluation Service, Inc. Issued September 1, 2007 This report is subject to re-examination in one year.

ESR ICC Evaluation Service, Inc. Issued September 1, 2007 This report is subject to re-examination in one year. ESR-2542 Issued September 1, 2007 This report is subject to re-examination in one year. ICC Evaluation Service, Inc. www.icc-es.org Business/Regional Office # 5360 Workman Mill Road, Whittier, California

More information

Viking Installation Guide

Viking Installation Guide Viking Installation Guide Professional Series Built-In Chimney-Style Hoods Viking Range Corporation 111 Front Street Greenwood, MIssissippi 38930 USA NOTE: IF INSTALLING HOOD WITH WARMING SHELF PANEL,

More information

PRESSURIZED STEEL BOILER WITH REVERSED FLAME

PRESSURIZED STEEL BOILER WITH REVERSED FLAME smoke pipes PRESSURIZED STEEL BOILER WITH REVERSED FLAME OUTPUT RANGE from 340 to 7000 WORKING TEMPERATURE minimum return temperature 55 OPERATION WITH gas or oil fired jet burners MODELS 340 420 510 630

More information

Technical and Dimensional Data. Double Wall One Inch Air Space AL 29-4C Stainless Steel Special Gas Vent

Technical and Dimensional Data. Double Wall One Inch Air Space AL 29-4C Stainless Steel Special Gas Vent Technical and Dimensional Data Saf-T Vent I Plus Double Wall One Inch ir Space L 29-4 Stainless Steel Special Gas Vent For Venting ommercial & Industrial ppliances ondensing ppliances ategory I,II,III,IV

More information

C A HEATING CABLE GLAND KIT INSTALLATION INSTRUCTIONS

C A HEATING CABLE GLAND KIT INSTALLATION INSTRUCTIONS C75-100-A HEATING CABLE GLAND KIT INSTALLATION INSTRUCTIONS DESCRIPTION The C75-100-A is a NEMA 4X-rated gland kit used to transition heating cables into a junction box when making connections off of a

More information

Date: Project #: Engineer: Prepared By: Bid Date:

Date: Project #: Engineer: Prepared By: Bid Date: NEOTHERM Hydronic Boiler NTH Hydronic Boiler Indoor Sizes 285-850 Date: Submittal Data Project #: Engineer: Project Name: Prepared By: Location: Bid Date: Contractor: Standard Equipment High condensing

More information

MODERUSTIC Battery Operated Remote Control Electronic Safety Pilot System IPI Intermittent Pilot Light For Fire Pits or Fireplaces

MODERUSTIC Battery Operated Remote Control Electronic Safety Pilot System IPI Intermittent Pilot Light For Fire Pits or Fireplaces MODERUSTIC Battery Operated Remote Control Electronic Safety Pilot System IPI Intermittent Pilot Light For Fire Pits or Fireplaces Model: AFVK-SP-MH/L Remote flame height adjustment DC Motor Drive Hi,

More information

SUMMARY. St-jean-sur-richelieu, January 15th 2016 Client: America s heat Project: PI-20114

SUMMARY. St-jean-sur-richelieu, January 15th 2016 Client: America s heat Project: PI-20114 SUMMARY 1 Introduction... 4 1.1 General... 4 1.2 Test unit information... 4 1.3 Results... 4 1.4 Pretest information... 4 2 Summary of test results... 5 2.1 table 1A: Data Summary Part A... 5 2.2 table

More information

Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes

Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes CANTEX INC. 301 Commerce Ste 2700 Fort Worth, Texas 76102 817-215-7000 Fax: 817-215-7001 Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes YOUR FULL

More information

SECTION AXIAL HVAC FANS

SECTION AXIAL HVAC FANS SECTION 233413 - AXIAL HVAC FANS 1. PART 1 GENERAL 1.1. RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Completing Your Fume Removal System

Completing Your Fume Removal System Once a laboratory hood has been selected, the next step is to select the proper blower and ductwork. It is important that these be sized correctly depending on hood size, application, CFM, and distance

More information

HS17. HS17 SERIES CONDENSING UNITS 17.6 to 65.2 kw ( to Btuh) Cooling Capacity. MATCHED REMOTE SYSTEMS 50hz ENGINEERING DATA

HS17. HS17 SERIES CONDENSING UNITS 17.6 to 65.2 kw ( to Btuh) Cooling Capacity. MATCHED REMOTE SYSTEMS 50hz ENGINEERING DATA ENGINEERING DATA ENGINEERING DATA MATCHED REMOTE SYSTEMS 50hz HS17 SERIES CONDENSING UNITS 17.6 to 65.2 kw (60 200 to 222 500 Btuh) HS17 Bulletin #490001 November 1995 Supersedes August 1994 HS17-1353

More information

Application & Reference Data Typical Specifications. Section 914 Vertical Turbine Fire Pump

Application & Reference Data Typical Specifications. Section 914 Vertical Turbine Fire Pump Section 914 Page 101 Supersedes Section 913 Page 101 Dated November 1, 199p Application & Reference Data Typical Specifications Section 914 Section 914 Page 102 Supersedes Section 913 Page 102 Dated November

More information

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER MEL TXD Model Features Exhaust air up to 3,400 CFM in high static pressure applications up to 1-1/4 w.g. Attractive spun aluminum exterior Direct drive units have low sound levels and quiet operation Non-overloading

More information

Technical and Dimensional Data. Double Wall One Inch Air Space AL 29-4C Stainless Steel Special Gas Vent

Technical and Dimensional Data. Double Wall One Inch Air Space AL 29-4C Stainless Steel Special Gas Vent Technical and Dimensional Data Saf-T Vent I Plus Double Wall One Inch ir Space L 29-4 Stainless Steel Special Gas Vent For Venting ommercial & Industrial ppliances ondensing ppliances ategory I,II,III,IV

More information