SELF-CONTAINED HEAT PUMP PACKAGE UNITS
|
|
- Ursula Wilkins
- 5 years ago
- Views:
Transcription
1 SELF-CONTAINED HEAT PUMP PACKAGE UNITS FORM NO. P REV. 2 Supersedes Form No. P Rev. 1 RQKA- STANDARD EFFICIENCY 10-SEER SERIES NOMINAL SIZES 3-4 TONS [ kw] (3 PHASE MODELS ONLY)
2 TABLE OF CONTENTS Unit Features & Benefits Model Identification Options General Data RQKA- Series...7 General Data Notes...8 Performance Data RQKA- Series Airflow Performance RQKA- Series...11 Electrical Data RQKA- Series...12 Electric Heater Kits Dimensional Data...15 Typical Installations...16 Accessories Typical Wiring...25 Limited Warranty
3 UNIT FEATURES & BENEFITSRQKA- SERIES These quality features are included in the Rheem Outdoor Package Heat Pumps 5 4 3
4 UNIT FEATURES & BENEFITSRQKA- SERIES Features Below Correspond to Photos on Page 3 1. All models feature Copeland Scroll compressors for maximum efficiency and quiet operation. 2. Louvered condenser compartment for protecting the coil against yard hazards and/or weather extremes. 3. One-piece top with a deep flange to help keep water out of the unit. 4. Supply and return air openings feature a one-inch tall flange to prevent water migration into the ductwork. 5. Access panels have weep holes and channels to further help manage water run-off. 6. Side and down discharge options available on all models. (Shipped Downflow Standard). 7. Easily accessible blower section complete with slideout blower. All units feature a system matched MultiFlex coil with low static pressure drop and excellent cooling capacities. 8. Refrigerant connections are conveniently located for easy service diagnostics. 9. Condenser and evaporator coils feature enhanced fins for better heat transfer and rifled copper tubing for greater efficiency. 10. Supplemental electric heat strips up to 15 kw are available (field or factory installed) for periods of extreme cold temperatures. Single point wiring makes installation even easier. 11. All units feature an internal trap on the condensate line eliminating the need for installing an on-site external trap. 12. Integral gasketing on the base rails is standard on those units shipped from the factory in the down-flow configuration. 13. Easily accessible control box. 4
5 MODEL IDENTIFICATIONRQKA- SERIES R Q K A A 036 C K 010 X X X Future Option Factory Installed Options (See Next Page) Heating Capacity (Factory Installed) 000 = No Resistance Heat 005 = 05 KW Resistance Heat ( ) 006 = 06 KW Resistance Heat ( ) 010 = 10 KW Resistance Heat ( ) 011 = 10 KW Resistance Heat (Canada) ( ) 015 = 15 KW Resistance Heat ( ) 016 = 15 KW Resistance Heat (Canada) ( ) Drive Package K = Direct Drive Electrical Designation C = V3PH60 Hz Cooling Capacity (BTUH) [kw] 036 = 36,000 [10.55] 042 = 42,000 [12.31] 048 = 48,000 [14.07] Future Technical Variations Design Series A = 1st Design Efficiency Designation K = 10 SEER Standard Efficiency Product Classification Q = Package Heat Pump Tradebrand R = Rheem 5
6 OPTIONSRQKA- SERIES Instructions for Factory Installed Option(s) Selection Note: Two characters following the model number will be utilized to designate a factory-installed option or combination of options. If no factory option(s) is required, nothing follows the model number. Step 1. After a basic rooftop model is selected, choose a two-character option code from the FACTORY INSTALLED OPTION SELECTION TABLE. FACTORY INSTALLED OPTION CODES Option Code AA AKA Example: RQKA-A036CK000XX (where XX is factory installed option) Example: No Options RQKA-A036CK000 Example: Options with Sideflow RQKA-A036CK000AKA Note: Factory installed economizer is not available on these models. Side Flow No Option x 6
7 NOMINAL SIZES 3-4 TONS [ kw] GENERAL DATARQKA- SERIES Model RQKA- Series A036CK A036JK A042CK A048CK Cooling Performance 1 Gross Cooling Capacity Btu [kw] 37,200 [10.9] 37,200 [10.9] 42,000 [12.3] 48,500 [1] EER/SEER 2 9.5/10 9.5/10 9.1/10 9/10 Nominal CFM/ARI Rated CFM [L/s] 1200/1200 [566/566] 1200/1200 [566/566] 1400/1400 [661/661] 1600/1500 [755/708] ARI Net Cooling Capacity Btu [kw] 36,000 [10.5] 36,000 [10.5] 40,500 [11.9] 46,500 [13.6] Net Sensible Capacity Btu [kw] 25,200 [7.4] 25,200 [7.4] 29,000 [8.5] 32,100 [9.4] Net Latent Capacity Btu [kw] 10,800 [3.2] 10,800 [3.2] 11,500 [3.4] 14,400 [] Net System kw Heating Performance (Heat Pumps) Heating Input Btu [kw] Rating 36,000 [10.5] 36,000 [10.5] 41,000 [12] 48,000 [1] System KW/COP 3.4/ / / /3.08 Low Temp. Btuh [kw] Rating 21,600 [6.3] 21,600 [6.3] 22,600 [6.6] 28,000 [8.2] System KW/COP 3.2/2 3.2/2 3.4/1.96 4/2.06 HSPF (Btu/Watts-hr) Compressor No./Type 1/Copeland Scroll 1/Copeland Scroll 1/Copeland Scroll 1/Copeland Scroll Outdoor Sound Rating (db) Outdoor CoilFin Type Louvered Louvered Louvered Louvered Tube Type Smooth Smooth Smooth Smooth Tube Size in. [mm] OD [9.5] [9.5] [9.5] [9.5] Face Area sq. ft. [sq. m] [1.15] [1.15] [1.15] [1.15] Rows / FPI [FPcm] 2 / 18 [7] 2 / 18 [7] 2 / 18 [7] 2 / 18 [7] Refrigerant Control TX Valves TX Valves TX Valves TX Valves Indoor CoilFin Type Louvered Louvered Louvered Louvered Tube Type Rifled Rifled Rifled Rifled Tube Size in. [mm] [7.9] [7.9] [7.9] [7.9] Face Area sq. ft. [sq. m] [0.94] [0.94] [0.94] [0.94] Rows / FPI [FPcm] 1 / 18 [7] 1 / 18 [7] 1 / 18 [7] 1 / 18 [7] Refrigerant Control TX Valves TX Valves TX Valves TX Valves Drain Connection No./Size in. [mm] 1/0.75 [19.05] 1/0.75 [19.05] 1/0.75 [19.05] 1/0.75 [19.05] Outdoor FanType Propeller Propeller Propeller Propeller No. Used/Diameter in. [mm] 1/22 [559] 1/22 [559] 1/22 [559] 1/22 [559] Drive Type/No. Speeds Direct/1 Direct/1 Direct/1 Direct/1 CFM [L/s] 2600 [1227] 2600 [1227] 2600 [1227] 3000 [1416] No. Motors/HP 1 at 1/5 HP 1 at 1/5 HP 1 at 1/5 HP 1 at 1/3 HP Motor RPM Indoor FanType FC Centrifugal FC Centrifugal FC Centrifugal FC Centrifugal No. Used/Diameter in. [mm] 1/10x9 [254x228.6] 1/10x9 [254x228.6] 1/10x9 [254x228.6] 1/10x9 [254x228.6] Drive Type/No. Speeds Direct/1 Direct/1 Direct/2 Direct/3 No. Motors Motor HP 1/3 1/3 1/2 3/4 Motor RPM Motor Frame Size FilterType Field Supplied Field Supplied Field Supplied Field Supplied Furnished No No No No (No.) Size Recommended in. [mm] (1)1x24x24 [25x610x610] (1)1x24x24 [25x610x610] (1)1x24x24 [25x610x610] (1)1x24x24 [25x610x610] Refrigerant Charge Oz. [g] 103 [2920] 103 [2920] 139 [3941] 138 [3912] Weights Net Weight lbs. [kg] 405 [184] 409 [186] 416 [189] 441 [200] Ship Weight lbs. [kg] 445 [202] 449 [204] 456 [207] 481 [218] See Page 8 for Notes. 7
8 GENERAL DATARQKA- SERIES NOTES: 1. Cooling Performance is rated at 95 F ambient, 80 F entering dry bulb, 67 F entering wet bulb. Gross capacity does not include the effect of fan motor heat. ARI capacity is net and includes the effect of fan motor heat. Units are suitable for operation to 20% of nominal cfm. Units are certified in accordance with the Unitary Air Conditioner Equipment certification program, which is based on ARI Standard 210/240 or EER and/or SEER are rated at ARI conditions and in accordance with DOE test procedures. 3. Outdoor Sound Rating shown is tested in accordance with ARI Standard
9 SYSTEMS PERFORMANCERQKA- SERIES GROSS SYSTEMS PERFORMANCE DATARQKA-A036 O UT D O O R D R Y B U LB T E M PE R AT U R E F [ C] 75 [23.9] 80 [26.7] 85 [29.4] 90 [32.2] 95 [35] 100 [37.8] 105 [40.6] 110 [43.3] 115 [46.1] ENTERING INDOOR 80 F [26.7 C] wbe 71 F [21.7 C] 67 F [19.4 C] 63 F [17.2 C] CFM [L/s] 1320 [623] 1200 [566] 1020 [481] 1320 [623] 1200 [566] 1020 [481] 1320 [623] 1200 [566] 1020 [481] DR ➀ [12.57] 23.4 [6.86] [12.25] 23.3 [6.83] [12.02] 23.1 [6.77] [11.78] 22.9 [6.71] [11.58] 22.5 [6.59] [11.34] 22.0 [6.45] [11.05] 21.5 [6.30] [10.67] 20.8 [6.10] 34.7 [10.17] 20.1 [5.89] [12.37] 22.2 [6.51] [12.05] 22.1 [6.48] [11.81] 21.9 [6.42] [11.58] 21.6 [6.33] [11.37] 21.3 [6.24] [11.14] 20.8 [6.10] [10.84] 20.2 [5.92] [10.46] 19.6 [5.74] 34.0 [9.96] 18.9 [5.54] [12.07] 20.4 [5.98] [11.75] 20.3 [5.95] [11.52] 20.1 [5.89] [11.28] 19.8 [5.80] [11.08] 19.4 [5.69] [10.84] 19.0 [5.57] [10.55] 18.4 [5.39] [10.17] 17.8 [5.22] 33.0 [9.67] 17.1 [5.01] [12.13] 28.2 [8.26] [11.81] 28.1 [8.24] [11.58] 27.9 [8.18] [11.37] 27.7 [8.12] [11.14] 27.3 [8.00] [10.90] 26.8 [7.85] [10.61] 26.3 [7.71] 34.9 [10.23] 25.6 [7.50] [9.76] 24.9 [7.30] [11.93] 27.0 [7.91] [11.63] 26.9 [7.88] [11.37] 26.7 [7.82] [11.17] 26.4 [7.74] [10.93] 26.1 [7.65] [10.70] 25.6 [7.50] [10.40] 25.0 [7.33] 3 [10.02] 24.4 [7.15] 32.6 [9.55] 23.7 [6.95] 4.4 GROSS SYSTEMS PERFORMANCE DATARQKA-A042 O UT D O O R D R Y B U LB T E M PE R AT U R E F [ C] 75 [23.9] 80 [26.7] 85 [29.4] 90 [32.2] 95 [35] 100 [37.8] 105 [40.6] 110 [43.3] 115 [46.1] 39.7 [11.63] 25.2 [7.39] [11.31] 25.1 [7.36] [11.08] 24.9 [7.30] [10.87] 24.6 [7.21] [10.64] 2 [7.09] [10.40] 23.8 [6.98] [10.11] 23.2 [6.80] [9.73] 22.6 [6.62] 31.6 [9.26] 21.9 [6.42] [11.63] 32.8 [9.61] [11.31] 32.7 [9.58] [11.08] 32.5 [9.52] [10.84] 32.2 [9.44] [10.64] 31.9 [9.35] [10.40] 31.4 [9.20] [10.11] 30.8 [9.03] [9.73] 30.2 [8.85] 31.5 [9.23] 29.5 [8.65] [11.43] 31.6 [9.26] [11.11] 31.5 [9.23] [10.87] 31.3 [9.17] [10.67] 31.0 [9.09] [10.43] 30.6 [8.97] [10.20] 30.2 [8.85] [9.91] 29.6 [8.67] [9.52] 29.0 [8.50] 30.9 [9.06] 28.3 [8.29] [11.14] 29.7 [8.70] [10.81] 29.7 [8.70] [10.58] 29.5 [8.65] [10.35] 29.2 [8.56] [10.14] 28.8 [8.44] [9.91] 28.4 [8.32] [9.61] 27.8 [8.15] [9.23] 27.2 [7.97] 29.8 [8.73] 26.4 [7.74] 4.3 ENTERING INDOOR 80 F [26.7 C] wbe 71 F [21.7 C] 67 F [19.4 C] 63 F [17.2 C] CFM [L/s] 1540 [727] 1400 [661] 1190 [562] 1540 [727] 1400 [661] 1190 [562] 1540 [727] 1400 [661] 1190 [562] DR ➀ DR Depression ratio dbe Entering air dry bulb wbeentering air wet bulb 48.6 [14] 27.1 [7.94] [14.07] 26.6 [7.80] [13.86] 26.3 [7.71] [13.60] 26.2 [7.68] [13.31] 26.0 [7.62] [12.98] 25.8 [7.56] 42.9 [12.57] 25.4 [7.44] [12.10] 24.8 [7.27] [11.58] 23.8 [6.98] [14.04] 25.7 [7.53] [13.83] 25.2 [7.39] [13.63] 24.9 [7.30] [13.36] 24.8 [7.27] [13.10] 24.6 [7.21] [12.75] 24.4 [7.15] 42.1 [12.34] 24.0 [7.03] [11.90] 23.4 [6.86] [11.34] 22.4 [6.56] [13.69] 23.6 [6.92] [13.51] 23.1 [6.77] [13.28] 22.9 [6.71] [13.04] 22.7 [6.65] [12.75] 22.6 [6.62] [12.40] 22.4 [6.56] 41.0 [12.02] 22.0 [6.45] [11.55] 21.3 [6.24] [11.02] 20.3 [5.95] 4.7 Total Total capacity x 1000 BTUH Sens Sensible capacity x 1000 BTUH KW input 46.1 [13.51] 32.0 [9.38] [13.33] 31.5 [9.23] [13.13] 31.2 [9.14] [12.87] 31.1 [9.11] [12.57] 30.9 [9.06] [12.25] 30.7 [9.00] 40.4 [11.84] 30.3 [8.88] [11.37] 29.7 [8.70] [10.84] 28.7 [8.41] [13.31] 30.6 [8.97] [13.10] 30.1 [8.82] [12.90] 29.9 [8.76] [12.66] 29.7 [8.70] [12.37] 29.6 [8.67] [12.02] 29.3 [8.59] 39.7 [11.63] 29.0 [8.50] [11.17] 28.3 [8.29] [10.64] 27.3 [8.00] [12.95] 28.5 [8.35] [12.78] 28.1 [8.24] [12.57] 27.8 [8.15] [12.31] 27.6 [8.09] [12.02] 27.5 [8.06] [11.69] 27.3 [8.00] 38.5 [11.28] 26.9 [7.88] 36.9 [10.81] 26.3 [7.71] [10.29] 25.3 [7.41] [12.98] 38.3 [11.22] [12.81] 37.8 [11.08] [12.60] 37.6 [11.02] [12.34] 37.4 [10.96] [12.05] 37.2 [10.90] [11.72] 37.0 [10.84] 38.6 [11.31] 36.7 [10.76] [10.84] 36.0 [10.55] [10.32] 35.0 [10.26] [12.78] 36.9 [10.81] [12.57] 36.4 [10.67] [12.37] 36.2 [10.61] [12.13] 36.0 [10.55] [11.84] 35.9 [10.52] [11.49] 35.7 [10.46] 37.9 [11.11] 35.3 [10.35] [10.64] 34.6 [10.14] [10.11] 33.6 [9.85] [12.43] 34.9 [10.23] [12.25] 34.4 [10.08] [12.05] 3 [9.99] [11.78] 33.9 [9.94] [11.49] 33.8 [9.91] [11.17] 33.6 [9.85] [10.76] 33.2 [9.73] 35.1 [10.29] 32.6 [9.55] [9.76] 31.6 [9.26] 4.6 NOTES: ➀ When the entering air dry bulb is other than 80 F [27 C], adjust the sensible capacity from the table by adding [1.10 x CFM x (1 DR) x (dbe 80)]. 9
10 SYSTEMS PERFORMANCERQKA- SERIES GROSS SYSTEMS PERFORMANCE DATARQKA-A048 O UT D O O R D R Y B U LB T E M PE R AT U R E F [ C] 75 [23.9] 80 [26.7] 85 [29.4] 90 [32.2] 95 [35] 100 [37.8] 105 [40.6] 110 [43.3] 115 [46.1] ENTERING INDOOR 80 F [26.7 C] wbe 71 F [21.7 C] 67 F [19.4 C] 63 F [17.2 C] CFM [L/s] 1650 [779] 1500 [708] 1280 [604] 1650 [779] 1500 [708] 1280 [604] 1650 [779] 1500 [708] 1280 [604] DR ➀ DR Depression ratio dbe Entering air dry bulb wbeentering air wet bulb 57.0 [16.71] 29.5 [8.65] 55.7 [16.32] 31.7 [9.29] [15.94] 32.2 [9.44] [15.59] 31.5 [9.23] [15.18] 30.1 [8.82] [14.77] 28.3 [8.29] [14.30] 26.7 [7.82] [13.80] 25.7 [7.53] [13.22] 25.8 [7.56] [16.44] 27.9 [8.18] 54.8 [16.06] 30.1 [8.82] [15.68] 30.6 [8.97] [15.33] 29.9 [8.76] [14.92] 28.5 [8.35] [14.51] 26.7 [7.82] [14.07] 25.1 [7.36] [13.54] 2 [7.06] [12.95] 2 [7.09] [16.06] 25.5 [7.47] 53.5 [15.68] 27.7 [8.12] [15.30] 28.2 [8.26] [14.95] 27.5 [8.06] [14.54] 26.1 [7.65] [13] 24.3 [7.12] [13.66] 22.7 [6.65] [13.16] 21.7 [6.36] [12.57] 21.8 [6.39] 5.6 Total Total capacity x 1000 BTUH Sens Sensible capacity x 1000 BTUH KW input 54.5 [15.97] 35.2 [10.32] 53.2 [15.59] 37.5 [10.99] [15.21] 38.0 [11.14] [14.83] 37.3 [10.93] [14.45] 35.8 [10.49] [14.04] 3 [9.99] [13.57] 32.4 [9.50] [13.04] 31.5 [9.23] [12.46] 31.6 [9.26] [15.71] 33.6 [9.85] 52.3 [15.33] 35.9 [10.52] 51.0 [14.95] 36.4 [10.67] [14.57] 35.7 [10.46] [18] 34.3 [10.05] [13.77] 32.5 [9.52] [13.31] 30.9 [9.06] [12.78] 29.9 [8.76] [12.19] 30.0 [8.79] [15.33] 31.2 [9.14] [14.95] 33.5 [9.82] 49.7 [14.57] 34.0 [9.96] [18] 33.3 [9.76] [13.80] 31.9 [9.35] [13.39] 30.1 [8.82] [12.92] 28.5 [8.35] [12.40] 27.5 [8.06] [11.81] 27.6 [8.09] [15.06] 40.4 [11.84] [14.68] 42.7 [12.51] 48.8 [14.30] 43.2 [12.66] [13.92] 42.5 [12.46] [13.54] 41.0 [12.02] [13.13] 39.2 [11.49] [12.66] 37.6 [11.02] [12.16] 36.6 [10.73] [11.58] 36.7 [10.76] [14.80] 38.8 [11.37] [14.42] 41.1 [12.05] 47.9 [14.04] 41.6 [12.19] [13.69] 40.9 [11.99] [13.28] 39.4 [11.55] [12.87] 37.6 [11.02] [12.40] 36.0 [10.55] [11.90] 35.0 [10.26] [11.31] 35.1 [10.29] [14.42] 36.4 [10.67] [14.04] 38.7 [11.34] 46.6 [13.66] 39.2 [11.49] [13.28] 38.5 [11.28] [12.90] 37.0 [10.84] [12.48] 35.2 [10.32] [12.02] 33.6 [9.85] [11.52] 32.6 [9.55] [10.93] 32.7 [9.58] 5.4 NOTES: ➀ When the entering air dry bulb is other than 80 F [27 C], adjust the sensible capacity from the table by adding [1.10 x CFM x (1 DR) x (dbe 80)]. 10
11 AIRFLOW PERFORMANCERQKA- SERIES INDOOR AIRFLOW PERFORMANCE208 VOLTS Nominal Cooling Capacity Tons [kw] Motor Speed from Factory 3.5 [12.31] High 3.0 [10.55] High 4.0 [14.07] Med Blower Size/ Motor HP [W] & # of Speeds 10 x 9 1/2 HP [373] 2 Speed Motor 10 x 9 1/3 HP [249] 1 Speed Motor 10 x 9 3/4 HP [559] 3 Speed Motor Motor Speed Med High High Low Med High CFM [L/s] Air Delivery/RPM/Watts208 Volts Side DischargeWet Coil External Static PressureInches W.C. [kpa] 0.1 [.02] 0.2 [.05] 0.3 [.07] 0.4 [.10] 0.5 [.12] 0.6 [.15] 0.7 [.17] CFM 1222 [577] 1197 [565] 1179 [556] 1162 [548] 1137 [537] 1097 [518] 1033 [488] RPM Watts CFM 1514 [715] 1461 [670] 1415 [668] 1370 [647] 1322 [624] 1266 [597] 1197 [565] RPM Watts CFM 1222 [577] 1201 [565] 1173 [556] 1137 [548] 1090 [537] 1030 [518] 954 [488] RPM Watts CFM 1179 [556] 1180 [557] 1183 [558] 1181 [557] 1169 [552] 1139 [538] 1087 [513] RPM Watts CFM 1719 [811] 1681 [793] 1634 [771] 1579 [745] 1516 [715] 1448 [683] 1373 [648] RPM Watts CFM 1954 [922] 1888 [891] 1816 [857] 1737 [820] 1655 [781] 1570 [741] 1483 [700] RPM Watts NOTES: Data reflects airflow with electric strip heat installed. WARNING: Do not operate unit in regions shown in bold (CFM greater than 1700 on 4 ton models) due to possibility of water blow-off. DOWN DISCHARGE PRESSURE DROP (ADD TO EXTERNAL STATIC PRESSURE) CFM [L/s] 600 [283] 800 [378] 1000 [472] 1200 [566] 1400 [661] Pressure DropInches W.C. [kpa] [.002].02 [.005].03 [.007].05 [.012] 1600 [775].07 [.017] 11
12 ELECTRICAL DATARQKA- SERIES Model No. RQKA- Unit Operating Voltage Range Minimum Circuit Ampacity Unit Information Minimum Overcurrent Protection Device Size Maximum Overcurrent Protection Device Size Evaporator Fan No. Volts Phase HP A036CK /21 25/25 35/ / / A042CK /20 25/25 30/ / / A048CK /30 35/35 45/ / / Amps (FLA) Amps (LRA) Model No. RQKA- Compressor Motor No. Volts Phase HP 2 RPM Amps 1 (RLA) Amps 1 (LRA) Condenser Motor No. Volts Phase HP 2 Amps 1 (FLA) A036CK 1 200/ / / / / / A042CK 1 200/ / / / / / A048CK 1 200/ / / / / Horsepower Per Compressor. 2. Amp Draw Per Motor. Multiply Value By Number of Motors to Determine Total Amps. Amps 1 (LRA) 12
13 ELECTRIC HEATER KITSRQKA- SERIES Unit Model Application Electric Heater Kit Models Country RXQJ-A10C ( volt, 3-ph, 10kW) USA & Canada RQKA-A036CK RXQJ-A12C ( volt, 3-ph, 12kW) USA Only RXQJ-A15C ( volt, 3-ph, 15kW) USA Only RXQJ-A16C ( volt, 3-ph, 15kW-Canadian) USA & Canada RXQJ-A10C ( volt, 3-ph, 10kW) USA & Canada RQKA-A042CK RXQJ-A12C ( volt, 3-ph, 12kW) USA Only RXQJ-A15C ( volt, 3-ph, 15kW) USA Only RXQJ-A16C ( volt, 3-ph, 15kW-Canadian) USA & Canada RXQJ-A10C ( volt, 3-ph, 10kW) USA & Canada RQKA-A048CK RXQJ-A12C ( volt, 3-ph, 12kW) USA Only RXQJ-A15C ( volt, 3-ph, 15kW) USA Only RXQJ-A16C ( volt, 3-ph, 15kW-Canadian) USA & Canada WARNING ONLY ELECTRIC HEATER KITS SUPPLIED BY THIS MANU- FACTURER AS DESCRIBED IN THIS PUBLICATION HAVE BEEN DESIGNED, TESTED, AND EVALUATED BY A NATION- ALLY RECOGNIZED SAFETY TESTING AGENCY FOR USE WITH THIS UNIT. USE OF ANY OTHER MANUFACTURED ELECTRIC HEATERS INSTALLED WITHIN THIS UNIT MAY CAUSE HAZARDOUS CONDITIONS RESULTING IN PROP- ERTY DAMAGE, FIRE, BODILY INJURY OR DEATH. 13
14 ELECTRIC HEATER KITSRQKA- SERIES AUXILIARY ELECTRIC HEATER KITS CHARACTERISTICS AND APPLICATION Model No. RQKA- A036C A042C A048C Heater Kit Nominal kw No Heat No Heat No Heat No. of Elements No. of Sequence Steps Volt, Single Phase and Three Phase, 60 HZ Rated Heater V 7.2/ / / / / / / / /14.4 Heater V 24.57/ / / / / / / / /49.13 Heater V 20.0/ / / / / / / / /34.7 Unit Min. Ckt V 21/21 46/50 51/56 59/65 20/20 45/49 49/54 57/63 30/30 55/59 60/64 68/73 Overcurrent Protective Device Size 208 V 25/35 50/50 60/60 60/60 25/30 45/50 50/50 60/60 35/45 60/60 60/70 70/ V 25/35 50/50 60/60 70/70 25/30 50/50 60/60 70/70 35/45 60/70 70/70 80/80 Copper Wire SizeAWG (1% Voltage Drop) SUPPLY WIRE LENGTH-FEET /0 1/0 2/0 2/0 3/0 3/0 3/0 4/0 4/0 4/0 4/ /0 1/0 2/0 2/0 2/0 3/0 3/0 3/0 4/0 4/0 4/0 4/0 4/ /0 1/0 1/0 2/0 2/0 2/0 3/0 3/0 3/0 3/0 3/0 4/0 4/0 4/ /0 1/0 1/0 1/0 2/0 2/0 2/0 2/0 2/0 3/0 3/ /0 1/0 1/0 1/ CIRCUIT AMPACITY Notes: 1. Wire size based on 60 C. type copper conductors below 100 ampacity. 2. Wire size based on 75 C. type copper conductors for 100 ampacity and above. 14
15 UNIT DIMENSIONSRQKA- SERIES UNIT DIMENSIONS SELF-CONTAINED AIR CONDITIONERS RQKA- 3-4 [ kw] TON MODELS 15
16 TYPICAL INSTALLATIONS 16
17 ACCESSORY EQUIPMENT Roofcurbs Accessory Description Model Application RQKA ACCESSORIES Accessory Model No. RXQG-AAA14 (14" [356 mm] Height) RXQG-AAA24 (24" [610 mm] Height) Supply & Return Diffusers RQKA RXRN-BD15 Economizers (Downflow Only) RQKA RXRE-CAA30 (3 Position) RXRD-CAM10 (Fully Modulating) Fresh Air Damper RQKA RXRF-FAB1 (Motorized-35%) RXRF-FAA1 (Fixed-35%) Rectangular to Round Transition (Downflow) RQKA RXMC-CA02 (16" [406 mm] Ducts) RXMC-CA03 (18" [457 mm] Ducts) Filter Kit RQKA RXRY-B01 High Pressure Control RQKA RXAB-A04 Outdoor Thermostat RQKA RXPT-A01 Monitor RQKA RXPM-B01 Low Ambient Control RQKA RXPZ-C01 or RXPZ-F01 Duct Adapter Sideflow Square to Round Transition RQKA RXMC-BA01 COMMON SUPPLY/RETURN CONCENTRIC AIR DIFFUSER SUPPLY/RETURN DIFFUSER Designed to convert a side by side or an over and under arrangement into a concentric distribution of air. The diffuser is flush mounted, completely insulated, assembled, and internally baffled to provide four way supply air distribution with a center return. To make the assembly complete and ready to fit into a 2' [0.61 m] x 4' [1.22 m] suspended ceiling grid, the diffuser includes adjustable supply louvers, hanging rings, anti-sweat gasket, and round flanges for use with flexible ducts. Model No. RXRN- BD15 Diameter Inches [mm] Shipping Wt. Lbs. [kg] 16 [406] 90 [40.82] Dimension A Inches [mm] 20 1 /2 [521] NOTE: The location of the combination supply and return diffuser should not exceed 10 feet [3.05 m] above the floor level for 1000 CFM [472 L/s] or less and 12 [3.66 m] to 14 feet [7 m] above the floor level for units with CFM greater than 1000 [472 L/s]. If the diffuser is installed with a greater distance than recommended above, the supply air may become stratified above the required comfort area causing uncomfortable conditions. AIRFLOW/PRESSURE DROP INFORMATION (INCHES W.C. [kpa]) Accessory Plenum & Supply/Return Duct Diffuser Approximate CFM [L/s]-Supply Air 1300 [614] 1575 [743] 1800 [850] 2200 [1038].07 [.017].10 [.024].09 [.022].13 [.032] SUPPLY AIR/PERFORMANCE.12 [.030].16 [.040].17 [.042].24 [.060] Economizer.06 [.015].09 [.022].11 [.027].17 [.042] Diffuser Airflow CFM [L/s] 800 [378]-1200 [566] 1600 [755]-2000 [944] Range of Throw Ft. [m] 14 [7]-16 [4.88] 18 [5.49]-28 [8.53] 17
18 ACCESSORIES DUCT ADAPTERS RECTANGULAR TO ROUND TRANSITIONS (DOWNFLOW) RXMC-CA02 RXMC-CA03 18
19 ACCESSORIES FRESH AIR DAMPER FOR USE ON RQKA- SERIES RXRF-FAA1 (Fixed %) The 0-35% manual outside Air Damper is designed to replace the unit return air duct cover. No drilling or damper assembly is required. The amount of outside air (0-35%) is controlled by simply adjusting the side damper. RXRF-FAB1 (Motorized %) The 0-35% motorized outside Air Damper is designed to replace the unit return air duct cover. No drilling or damper assembly is required. The control motor opens the adjustable slide damper when the unit blower motor is energized. ECONOMIZERS RXRE-CAA30 (3 Position) and RXRD-CAM10 (Fully Modulating) for RQKA- Series RXRE-CAA30 (3 Position) Provided with enthalpy control, and mixed air sensor. Settings include fully open, fully closed and adjustable mid point. RXRD-CAM10 (Fully Modulating) Provided with enthalpy control, mixed air sensor and minimum position potentiometer for proportioning (modulating) the amount of fresh air. 19
20 ACCESSORIES FILTER KIT INSTALLATION RXRY-B01 For use in either vertical or horizontal discharge. Model No. Minimum Airflow RQKA- 680 [321] RQKA- 850 [401] RQKA [481] RQKA [562] CFM [L/s] Nominal Airflow RQKA- 510 [241] 600 [283] 660 [311] 800 [378] 1000 [472] 1200 [566] 1400 [661] RQKA [602] 1500 [708] Maximum Airflow 880 [415] 1100 [519] 1320 [623] 1540 [727] 1650 [779] RQKA [802] 2000 [944] 2200 [1039] CFM [L/s] Airflow Pressure Drop, Inches W.C. [kpa] 1" Filter 2" Filter 500 [236].02 [.0050].03 [.0075] 600 [283].02 [.0050].03 [.0075] 700 [330].03 [.0075].04 [.0010] 800 [378].04 [.0010].05 [.0124] 900 [425].05 [.0124].06 [.0149] 1000 [472].07 [.0174].08 [.0199] 1100 [519].08 [.0199].09 [.0224] 1200 [566].10 [.0249].12 [.0299] 1300 [614].13 [.0324].15 [.0373] 1400 [661].16 [.0398].19 [.0473] 1500 [708].19 [.0473].21 [.0523] 1600 [755].20 [.0498].23 [.0572] 1700 [802].21 [.0523].24 [.0598] 1800 [850].22 [.0548].25 [.0623] 1900 [897].24 [.0598].27 [.0672] 2000 [944].26 [.0647].29 [.0722] 20
21 ACCESSORIES DUCT ADAPTER SIDEFLOW SQUARE TO ROUND TRANSITION RXMC-BA01 Adapts the side rectangular supply and return openings to 14" [356 mm] diameter round openings. Adapters provided with same finish as unit and also provided with thermal insulation. 21
22 ACCESSORIES Roofcurb (Sloped) RXQG-AAA14 & RXQG-AAA24 for RQKA- Series Heat pump models must use sloped curbs. Hinged corners make for fast, easy set-up. RXQG-AAA14 (14" [356 mm] High) RXQG-AAA24 (24" [610 mm] High) Packaged Heat Pump Roofcurb Installation (Sloped) 22
23 ROOFCURB ADAPTERS Fabricated from galvanized steel to adapt the New cabinet to the old style curb. All are furnished with a New gasket. ACCESSORIES OLD MODEL PACKAGE HEAT PUMP OLD CURB MODEL NEW MODEL TO OLD MODEL ROOFCURB ADAPTER NEW MODEL PACKAGE HEAT PUMP SMALL CABINET (1 1 /2-2 TON) [ kw] RPNC- RPND- 20 SERIES RXPA-CA20 ONLY 1 CABINET SIZE ALL MODELS MEDIUM CABINET (2 1 /2-3 TON) [ kw] RPNC- RPND- 21 SERIES RXPA-CA21 RXPX-BACCA20 RXPX-BACCA21 RXPX-BACCA23 RQKA- EXTRA LARGE CABINET (3 1 /2-5 TON) [ kw] RPNC- RPND- (1) SLOPE TYPE (2) FULL PERIMETER TYPE 23 SERIES RXPA-CA23 23
24 ACCESSORIES LIFT KITMODEL NO. RXML-A01 The lift kit is intended for temporary installation while the unit is being lifted into position. Kit includes 4 lift brackets. 24
25 WIRING SCHEMATICSRQKA- SERIES 25
26 NOTES 26
27 27 NOTES
28 BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE FROM YOUR RETAILER. GENERAL TERMS OF LIMITED WARRANTY Rheem will furnish a replacement for any part of this product which fails in normal use and service within the applicable periods stated, in accordance with the terms of the limited warranty. For Complete Details of the Limited Warranty, Including Applicable Terms and Conditions, See Your Local Installer or Contact the Manufacturer for a Copy. *Condenser Coil and Evaporator Coil leaks caused by factory defects...five (5) Years *Compressor (3 Phase models)...five (5) Years *Any Other Part...One (1) Year *All other parts and components carry a limited warranty of five years, provided they are single-phase products installed in a residential application. Before proceeding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal, State, Provincial, and Local codes, regulations, and practices. RHEEM AIR CONDITIONING DIVISION 5600 Old Greenwood Road, Fort Smith, Arkansas In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice. PRINTED IN U.S.A DC FORM NO. P REV. 2 Supersedes Form No. P Rev. 1
Package Air Conditioners
MODEL: RACA14 Package Air Conditioners FORM NO. SSC-969 REV. 1 Sure Comfort RACA14 Package Air Conditioners RACA14 14 SEER Nominal Sizes 2-5 Tons [7.0-17.6 kw] Proper sizing and installation of equipment
More informationPACKAGE AIR CONDITIONERS
PACKAGE AIR CONDITIONERS FORM NO. S22-92 REV. 2 Supersedes Form No. S22-92 Rev. RLNA- SUPER HIGH EFFICIENCY SERIES NOMINAL SIZES -5 TONS [0.6-7.6 kw] *Unit shown with optional louver panels installed..0
More informationPACKAGE GAS / ELECTRIC ROOFTOP UNITS FORM NO. EXR REV. 4 Supersedes Form No. EXR Rev. 3
PACKAGE GAS / ELECTRIC ROOFTOP UNITS FORM NO. EXR22-845 REV. 4 Supersedes Form No. EXR22-845 Rev. 3 SKKL- STANDARD EFFICIENCY SERIES NOMINAL SIZES 6 TON [21.1 kw] (50 Hz, 3 PHASE ONLY) RATED IN ACCORDANCE
More informationRheem Commercial Classic Series Package Air Conditioner
Package Air Conditioner SNL/SPL Series heem Commercial Classic Series Package Air Conditioner SNL- 13 SEE Series Nominal Sizes 2-5 Tons [7.0-17.6 kw] SPL- 14 SEE Series Nominal Sizes 2-5 Tons [7.0-17.6
More informationPACKAGE HEAT PUMP UNITS
PACKAGE HEAT PUMP UNITS FOM NO. PTZ-77 EV. Supersedes Form No. PTZ-77 ev. 2 Featuring Earth-Friendly -40A efrigerant earth friendly refrigerant TZCHC- SEE HIGH EFFICIENCY SEIES NOMINAL SIZES -5 TONS [0.6-7.6
More informationPACKAGE GAS ELECTRIC UNITS
PACKAGE GAS ELECTIC UNITS FOM NO. TZ-870 EV. 1 TZGE4 14 SEE SEIES NOMINAL SIZES 2-5 TONS [7.0-17.6 kw] TZGE5 15 SEE SEIES NOMINAL SIZES 2-5 TONS [7.0-17.6 kw] NL 1 PL 14.0 L 16.0 ATED IN ACCODANCE (15
More informationRuud Commercial Achiever Series Package Heat Pump. Package Heat Pump
Package Heat Pump QPL Series uud Commercial Achiever Series Package Heat Pump QPL- High fficiency 14-S Series Nominal Sizes 2-4 Tons [7.03-17 kw] ely on uud. FM N. P22-791 V. 5 Table of Contents QPL Series
More informationSELF-CONTAINED COOLING PACKAGE UNITS
SELF-CONTAINED COOLING PACKAGE UNITS FOM NO. S11-929 EV. 2 Supersedes Form No. S11-929 ev. 1 SKA- STANDAD EFFICIENCY 10-SEE SEIES NOMINAL SIZES 3-5 TONS [10.6-17.6 kw] (3 PHASE MODELS ONLY) TABLE OF CONTENTS
More informationGAS HEAT/ELECTRIC COOLING PACKAGE UNITS
GAS HEAT/ELECTIC COOLING PACKAGE UNITS FOM NO. 11-834 EV. 3 Supersedes Form No. 11-834 ev. 2 KA- STANDAD EFFICIENCY 10-SEE SEIES NOMINAL SIZES 3-5 TONS [10.6-17.6 kw] (3 PHASE MODELS ONLY) TABLE OF CONTENTS
More informationPACKAGE HEAT PUMPS. Featuring Earth-Friendly R-410A Refrigerant RQNL-B HIGH EFFICIENCY 13-SEER SERIES RQPL-B HIGH EFFICIENCY 14-SEER SERIES
PACKAG HAT PMPS FM N. P66-767 Featuring arth-friendly -40A efrigerant earth friendly refrigerant QNL-B HIGH FFICINCY 3-S SIS NMINAL SIZS 2-4 TNS [7.03-4.07 kw] QPL-B HIGH FFICINCY 4-S SIS NMINAL SIZS 2-4
More informationRuud Commercial Achiever Series Package Air Conditioner. Package Air Conditioner
Package Air Conditioner Ruud Commercial Achiever Series Package Air Conditioner RLKN-B Standard Efficiency Series Nominal Sizes 6 Tons [21.1 kw] (3 Phase Models Only) Rely on Ruud. FORM NO. S22-973 REV.
More informationRuud Commercial Achiever Series Package Heat Pump
Package Heat Pump Ruud Commercial Achiever Series Package Heat Pump RJNL-B High Efficiency Series Nominal Sizes 7.5 & 10 Tons [26.4 & 35.2 kw] ASHRAE 90.1-2010 Compliant Models Rely on Ruud. FORM NO. P22-794
More informationSELF-CONTAINED COOLING PACKAGE UNITS
SELF-CONTAINED COOLING PACKAGE UNITS FORM NO. S11-931 REV. 4 Supersedes Form No. S11-931 Rev. 3 RLKB- STANDARD EFFICIENCY SERIES NOMINAL SIZES 15-25 TONS [52.8-87.9 kw] ASHRAE 90.1-1989 COMPLIANT MODELS
More informationHEAT PUMPS CLASSIC X HEAT PUMPS RPKA- SERIES. Nominal Sizes 1 1 /2 to 5 Tons [5.28 to kw]
FORM NO. P11-729 REV. 6 Supersedes Form No. P11-729 Rev. 5 HEAT PUMPS CLASSIC X HEAT PUMPS RPKA- SERIES Nominal Sizes 1 1 /2 to 5 Tons [5.28 to 17.58 kw] The Rheem RPKA- Heat Pump Outdoor units can provide
More informationHEAT PUMPS UPKB- SERIES. Seven Models
FORM NO. P22-754 REV. 1 Supersedes Form No. P11-729 Rev. 8 HEAT PUMPS UPKB- SERIES Seven Models 10 SEER with efficiencies ranging up to 10.30 SEER in certain matched systems. Nominal Sizes 1 1 /2 to 5
More informationPACKAGE AIR CONDITIONERS
PACKAGE AI CNDITINES FM N. EXA-86 SSNM- HIGH EFFICIENCY 50 Hz EXPT AI CNDITINE NMINAL SIZES 2, 3-6 TN [7, 0.6-2. kw] -40A efrigerant TABLE F CNTENTS nit Features & Benefits...3-6 Model Identification ptions...7
More informationSELF-CONTAINED COOLING PACKAGE UNITS
SELF-CONTAINED COOLING PACKAGE UNITS FORM NO. STZ-957 TZCAC- STANDARD EFFICIENCY SERIES NOMINAL SIZES 15-25 TONS [52.8-87.9 kw] ASHRAE 90.1-2007 COMPLIANT MODEL Manufactured for Thermal Zone Philadelphia,
More informationCONDENSING UNITS RAKB- SERIES. Seven Models
FORM NO. A11-168 REV. 2 Supersedes Form No. A11-168 Rev. 1 Supersedes Form No. A11-147 Rev. 8 CONDENSING UNITS SERIES Nominal Sizes 1 1 /2 to 5 Tons [5.28 kw] to [17.58 kw] Seven Models 10 SEER with efficiencies
More informationRheem Commercial Value Series Package Gas Electric Unit
Package Gas Electric Rheem Commercial Value Series Package Gas Electric Unit RKKL-B Standard Efficiency Series Nominal Sizes 6 Ton [2. kw] ASHRAE 90.-200 Compliant Models Proper sizing and installation
More information13 SEER HEAT PUMPS Features Coils constructed with copper tubing and enhanced aluminum
FORM NO. P11-5 REV. 6 Supersedes Form No. P11-5 Rev. 5 13PJA SERIES 13 SEER HEAT PUMPS Features Coils constructed with copper tubing and enhanced aluminum fins. Strong, attractive cabinetlouvered design
More informationAIR HANDLERS AIR HANDLERS. RHPN- SERIES 18 SEER featuring Earth-Friendly R-410A Refrigerant. Features
FORM NO. H11-528 Supersedes Form No. H11-526 Rev. 1 AIR HANDLERS AIR HANDLERS RHPN- SERIES 18 SEER featuring Earth-Friendly R-410A Refrigerant Features earth friendly refrigerant Includes an energy efficient
More informationPACKAGE AIR CONDITIONERS
PACKAGE AI CNDITINES FM N. STZ-950 TZAH- HIGH EFFICIENCY 13-SEE SEIES NMINAL SIZES 2-5 TNS [7-17.6 kw] Table of Contents TABLE F CNTENTS nit Features & Benefits...3-6 Model Number Identification...7 General
More informationCONDENSING UNITS CLASSIC X CONDENSING UNITS RAKA- SERIES. Seven Models. Cooling Capacities 17,000 to 56,500 BTU/HR [4.98 kw] to [16.
FORM NO. A11-147 REV. 9 Supersedes Form No. A11-147 Rev. 8 CONDENSING UNITS CLASSIC X CONDENSING UNITS Seven Models Cooling Capacities 17,000 to 56,500 BTU/HR [4.98 kw] to [16.56 kw] SERIES Nominal Sizes
More informationHEAT PUMP AIR HANDLERS AND FAN COIL UNIT
FORM NO. H66-515 Supersedes Form No. H66-5 Rev. 1 HEAT PUMP AIR HANDLERS AND FAN COIL UNIT Features 1 1 /2 ton [5 kw] through 5 ton [18 kw] models are always just 35 inches [889 mm] tall and 22 inches
More informationAIR HANDLERS RBHC- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT
FORM NO. H11-517 REV. 1 Supersedes Form No. H11-509 Rev. 7 AIR HANDLERS RBHC- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT Features 1 1 /2 ton [5.3 kw] through 5 ton [17.6 kw] models are always just
More informationHEAT PUMPS UPLB- SERIES. Seven Models
FORM NO. P22-755 Supersedes Form No. P11-732 Rev. 6 HEAT PUMPS UPLB- SERIES Seven Models 11 SEER with efficiencies ranging up to 12 SEER in certain matched systems. Nominal Sizes 1 1 /2 to 5 Tons [5.28
More information13 SEER HEAT PUMPS Features Coils constructed with copper tubing and enhanced aluminum
FORM NO. P22-5 REV. 7 Supersedes Form No. P22-5 Rev. 6 13PJA SERIES 13 SEER HEAT PUMPS Features Coils constructed with copper tubing and enhanced aluminum fins. Strong, attractive cabinetlouvered design
More informationAIR HANDLERS RBHM- SERIES AIR HANDLERS AND FAN COIL UNIT
FORM NO. H11-521 AIR HANDLERS earth friendly refrigerant RBHM- SERIES AIR HANDLERS AND FAN COIL UNIT Features Versatile 3-way convertible design for upflow, horizontal left and horizontal right. Available
More information13 SEER HEAT PUMPS Features Coils constructed with copper tubing and enhanced aluminum
FORM NO. P66-774 Supersedes Form No. P66-765 Rev. 4 Featuring Earth-Friendly R-410A Refrigerant 13PJL SERIES earth friendly refrigerant 13 SEER HEAT PUMPS Features Coils constructed with copper tubing
More informationTons BTU/h S.E.E.R* E.E.R** HSPF
SOUND REFRIGERANT ENVIRONMENTALLY PHD3 Product Specifications 13 SEER, R -410A PACKAGE HEAT PUMP, 2½ to 5 TONS 3 -Phase, 208/230-3 -60 and 460-3 -60 REFRIGERATION CIRCUIT R--410A refrigerant Copper tube/aluminum
More informationAIR HANDLERS RBHK- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT
FORM NO. H11-516 REV. 1 Supersedes Form No. H11-516 Rev. 0 AIR HANDLERS RBHK- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT Features Versatile 4-way convertible design for upflow, downflow, horizontal
More informationPACKAGE GAS ELECTRIC UNITS
PACKAGE GAS ELECTIC UNITS FOM NO. TZ-838 EV. 2 Supersedes Form No. TZ-838 ev. TZGE-3**JA SUPE HIGH EFFICIENCY 3-SEE SEIES NOMINAL SIZES 2-5 TONS [7.0-7.6 kw] Manufactured for Thermal Zone Philadelphia,
More informationPACKAGE GAS / ELECTRIC ROOFTOP UNITS
PACKAGE GAS / ELECTRIC ROOFTOP UNITS FORM NO. RTZ-858 Featuring Industry Standard R-410A Refrigerant TZCGE- STANDARD EFFICIENCY SERIES NOMINAL SIZES 7.5, 10 & 12.5 TONS [26.4, 35.2 & 44.0 kw] Table of
More informationPHF SERIES THREE PHASE CONVERTIBLE SINGLE PACKAGE HEAT PUMP
PHF SERIES UNITARY AIR-CONDITIONING MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH ARI THREE PHASE EQUIPMENT STANDARD 210 Rated in accordance with ARI Standard Listed By 240. Certification applies only
More informationAIR HANDLERS UBHN- SERIES AIR HANDLERS AND FAN COIL UNIT PRELIMINARY NOT FOR DISTRIBUTION
FORM NO. H22-522 AIR HANDLERS earth friendly refrigerant PRELIMINARY NOT FOR DISTRIBUTION UBHN- SERIES AIR HANDLERS AND FAN COIL UNIT Features Versatile 3-way convertible design for upflow, horizontal
More informationQ6SP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.
TECHNICAL SPECIFICATIONS Q6SP Series 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1 These 7½ and 10 ton units are designed specifically
More information14.5 SEER HEAT PUMPS. Featuring New Industry Standard R-410A Refrigerant TZPL SERIES
FORM NO. PTZ-781 Supersedes Form No. PTZ-781 Featuring New Industry Standard R-410A Refrigerant TZPL SERIES Manufactured for Thermal Zone Philadelphia, PA (IN CERTAIN MATCHED SYSTEMS) 14.5 SEER HEAT PUMPS
More informationMODEL: RJNL-C. Package Heat Pump. With ClearControl Nominal Sizes 7.5 & 10 Ton [26.4 & 35.2 kw] ASHRAE Compliant Models
MODEL: RJNL-C Package Heat Pump FORM NO. PSC-793 Sure Comfort RJNL-C High Efficiency Package Heat Pump RJNL-C High Efficiency With ClearControl Nominal Sizes 7.5 & 10 Ton [26.4 & 35.2 kw] ASHRAE 90.1-2010
More informationRheem Commercial Classic Series Package Gas Electric Unit
Package Gas Electric Rheem Commercial Classic Series Package Gas Electric Unit RKNL-C 3 SEER Series RKPL-C 4 SEER Series With ClearControl Nominal Sizes 3-5 Tons [0.6-7.6 kw] (4 SEER ONLY) SINGLE PHASE
More informationQ6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.
TECHNICAL SPECIFICATIONS Q6SP Series Rev A 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1-2010 These 7½ and 10 ton units are designed
More informationPACKAGE AIR CONDITIONERS
PACKAGE AI CNDITINES FM N. A11-179 EV. 6 Supersedes Form No. A11-179 ev. 5 SNJ- SPE HIGH EFFICIENCY 13-SEE SEIES NMINAL SIZES 2-5 TN [7-17.6 kw] TABLE F CNTENTS nit Features & Benefits...3-6 Model Identification
More informationCONVERTIBLE SINGLE PACKAGE HEAT PUMP
PHA D SERIES UNITARY AIRCONDITIONING MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH ARI EQUIPMENT STANDARD 210 CONVERTIBLE SINGLE PACKAGE HEAT PUMP FEATURE SINGLE PACKAGE, 2 THRU 5 TON COOLING Single
More informationAIR HANDLERS AIR HANDLERS. UHKA- SERIES featuring R-22 Refrigerant UHKL- SERIES featuring Earth-Friendly R-410A Refrigerant.
FORM NO. H22-523 REV. 4 Supersedes Form No. H22-523 Rev. 3 AIR HANDLERS AIR HANDLERS UHKA- SERIES featuring R-22 Refrigerant UHKL- SERIES featuring Earth-Friendly R-410A Refrigerant Features earth friendly
More informationRuud Commercial Achiever Series Package Gas Electric Unit
Package Gas Electric Ruud Commercial Achiever Series Package Gas Electric Unit RKPN-C 14 SEER Series RKQN-C 15 SEER Series With ClearControl Nominal Sizes 3-5 Tons [10.6-17.6 kw] (14 SEER ONLY) SINGLE
More informationQ6SE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase
TECHNICAL SPECIFICATIONS Q6SE Series Single Packaged Heat Pump, Single Phase Q6SE-14 SEER, 8.0 HSPF 2-5 Ton Units Cooling: 23,000 to 58,000 Btuh Heating: 22,800 to 59,000 Btuh The Q6 Series single packaged
More informationPHR5. Product Specifications
PHR5 Product Specifications UP to 15.5 SEER, UP to 12.5 EER, PACKAGE HEAT PUMP UNITS, 2 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally balanced R
More informationCHP
Packaged Unit Heat Pump CHP16-024-030-036-048-060 2-5 Ton Cooling 23,000-57,500 Btuh Heating 12,800-85,300 Btuh (5-25 kw) Optional Electric Heating FEATURES Designed for outdoor rooftop or ground level
More informationP6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units
TECHNICAL SPECIFICATIONS P6SP Series Rev A 6, 7½ and 10 Ton Packaged Electric Cooling Units 11.2 EER Commercial System Units These units are designed specifically for retrofit applications and compatibility
More informationRuud Commercial Achiever Series Package Gas Electric Unit
Package Gas Electric RKNN-C/RKPN-C/RKQN-C Series Ruud Commercial Achiever Series Package Gas Electric Unit RKNN-C 13 SEER Series RKPN-C 14 SEER Series RKQN-C 15 SEER Series With ClearControl Nominal Sizes
More information13 SEER CONDENSING UNITS
FORM NO. ATZ-218 REV. 1 Supersedes Form No. ATZ-205 Featuring Industry Standard R-410A Refrigerant 13 SEER CONDENSING UNITS Features Painted louvered steel cabinet. Easily accessible control box. Condenser
More informationCONDENSING UNITS ACHIEVER 12 SUPER HIGH EFFICIENCY CONDENSING UNITS UAMA- SERIES. Seven Models
FORM NO. A22-149 REV. 6 Supersedes Form No. A22-149 Rev. 5 CONDENSING UNITS ACHIEVER 12 SUPER HIGH EFFICIENCY CONDENSING UNITS SERIES Nominal Sizes 1 1 /2 to 5 Tons [5.28 kw] to [17.58 kw] Seven Models
More informationQ4SD Series TECHNICAL SPECIFICATIONS. Single Packaged Heat Pump, Single Phase FEATURES AND BENEFITS
TM TECHNICAL SPECIFICATIONS Q4SD Series Single Packaged Heat Pump, Single Phase Q4SD-13 SEER 3-5 Ton Units Cooling: 30,000 to 58,000 Btuh Heating: 29,000 to 59,000 Btuh The Q4 Series single packaged heat
More information14.5 SEER HEAT PUMPS. Featuring Industry Standard R-410A Refrigerant TZPL SERIES. Features Coils constructed with copper tubing and enhanced aluminum
FORM NO. PTZ-803 Supersedes Form No. PTZ-781 Featuring Industry Standard R-410A Refrigerant TZPL SERIES Efficiencies up to 14.5 SEER/12.00 EER/8.50 HSPF Nominal Sizes 1.5 to 5 Tons [5.28 kw] to [17.6 kw]
More informationQ6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase
TECHNICAL SPECIFICATIONS Q6SD Series Single Packaged Heat Pump, Single Phase Q6SD-13 SEER, R-410A 2-5 Ton Units Cooling: 22,800 to 58,500 Btuh Heating: 22,800 to 58,500 Btuh The Q6 Series single packaged
More informationRCBA- MULTIFLEX INDOOR COILS
FORM NO. C11-207 REV. 3 Supersedes Form No. C11-207 Rev. 2 RCBA- MULTIFLEX INDOOR S AIRFLOW CAPACITIES 600-2000 CFM [218-944 L/s] Rheem Value Series Indoor Coils are designed for use with Rheem Value Series
More informationFORM NO. HSC-543 AIR HANDLERS
FORM NO. HSC- AIR HANDLERS AH10X1 High Efficiency featuring New Industry Standard R-10A Refrigerant Features AH10X1 features the new X-1 (ECM) motor which provides enhanced SEER performance with most Sure
More informationCPC Commercial. 15- & 20-Ton, Three-Phase Packaged Air Conditioner. 20-Ton Cooling Capacity: 240,000 BTU/h
CPC Commercial 15- & 20-Ton, Three-Phase Packaged Air Conditioner 15-Ton Cooling Capacity: 180,000 BTU/h 20-Ton Cooling Capacity: 240,000 BTU/h Contents Nomenclature...2 Product Features...3 Product Specifications...4
More informationZHA/ZHB SERIES WARNING
Service Literature Corp. 09-L Revised 7-08 ZHA/ZHB SERIES, 4, 5 and 6 ton 0.6 to kw ZHA/ZHB06, 048, 060, 07 The ZHA/ZHB packaged electric heat pump units are available in standard cooling efficiency (06S,
More informationRheem Air Handlers. RHLP- Standard Efficiency X-13 (ECM) Motor
Air Handlers Rheem Air Handlers RHLP- Standard Efficiency X-13 (ECM) Motor RHLP features an X-13 (ECM) motor which provides enhanced SEER performance with most Rheem outdoor units. 1 1 /2 ton [.3 kw] through
More informationP4SD Series Single Packaged Air Conditioning, 13 SEER 3, 4 and 5 Ton Units
TM TECHNICAL SPECIFICATIONS P4SD Series Single Packaged Air Conditioning, 13 SEER 3, 4 and 5 Ton Units The P4 Series single packaged air conditioners are high efficiency self contained cooling units that
More informationS5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS
TECHNICAL SPECIFICATIONS S5BP Series Split System Air Conditioner 71/2 Ton Energy Star rated at 11.7 EER and 11.8 IEER 10 Ton rated at 11.2 EER and 11.5 IEER R-410A Refrigerant The S5BP Series of air conditioners
More informationR6GI Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS
TECHNICAL SPECIFICATIONS R6GI Series Single Packaged Gas/Electric Units 20 SEER 81% AFUE Multi-Stage Cool/Two-Stage Heat 2-5 Ton Single-Phase Units The iq Drive gas/electric packaged system features modulating
More informationR6GF Series Rev B TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Gas/Electric Units Two-Stage Heat/Cool with Variable Speed Blower
TECHNICAL SPECIFICATIONS R6GF Series Rev B Single Packaged Gas/Electric Units Two-Stage Heat/Cool with Variable Speed Blower R6GF 15 SEER, 81% AFUE 2-5 Ton Units These single packaged gas/electric systems
More informationP6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioning, 13 SEER. 3, 4, 5 Ton Units
TECHNICAL SPECIFICATIONS P6SD Series Single Packaged Air Conditioning, 13 SEER 3, 4, 5 Ton Units The P6 Series single packaged air conditioners are high efficiency self contained cooling units that can
More informationPHF SERIES. THREE PHASE 50 Hz OPERATION CONVERTIBLE SINGLE PACKAGE HEAT PUMP
PHF SERIES THREE PHASE 50 Hz OPERATION CONVERTIBLE SINGLE PACKAGE HEAT PUMP 400v- 3-50 Hz FOR EXPORT USE Combination heating and cooling, self-contained for year-round comfort. Systems install on rooftop
More informationPCB COMMERCIAL SERIES
PCB COMMERCIAL SERIES 50 Hz SELF-CONTAINED PACKAGE CONDITIONER 7½, 0, AND 5 TON [6.4 kw to 5.8 kw] COOLING CAPACITY: 90,000 TO 80,000 BTU/H The PCB Commercial 50 Hz self-contained packaged air conditioner
More informationCPC Series. Submittal Data Form. 15- & 20-Ton Self-Contained. Packaged Air Conditioner. with R-410A
CPC Series 15- & 20-Ton Self-Contained Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: Packaged Air Conditioner with R-410A
More informationGPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H
H Cooling Capacity: 24,000-57,500 BTU/H 2- to 5-Ton Packaged Air Conditioner 14 SEER Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 4 Airflow Data... 16 Heater Kit Specifications...
More informationGR4GC Series Single Packaged Gas/Electric Units
TECHNICAL SPECIFICATIONS GR4GC Series Single Packaged Gas/Electric Units GR4GC 12 SEER, Three Phase 3 Ton thru 5 Ton Units The GR4GC Series single packaged gas/electrics are high efficiency self contained
More informationGPH13H PRODUCT SPECIFICATIONS 13 SEER PACKAGED HEAT PUMP 2 TO 5 TONS COOLING CAPACITY: 25,000-57,000 BTU/H HEATING CAPACITY: 24,000-54,400 BTU/H
GPH13H PACKAGED HEAT PUMP 13 SEER 2 TO 5 TONS COOLING CAPACITY: 25,000-57,000 BTU/H HEATING CAPACITY: 24,000-54,400 BTU/H The Goodman GPH13H 13 SEER Packaged Heat Pump provides energy-efficient cooling
More informationGQ4SD Series. Single Packaged Heat Pump 13 SEER TECHNICAL SPECIFICATIONS
TM TECHNICAL SPECIFICATIONS GQ4SD Series Single Packaged Heat Pump 13 SEER The GQ4 Series single packaged units are high efficiency self contained cooling and heating units that can be installed on a roof
More informationGR4GD Series. Single Packaged Gas/Electric Units TECHNICAL SPECIFICATIONS. GR4GD 13 SEER 2 Ton thru 5 Ton Units FEATURES AND BENEFITS
TECHNICAL SPECIFICATIONS GR4GD Series Single Packaged Gas/Electric Units GR4GD 13 SEER 2 Ton thru 5 Ton Units The GR4GD Series single packaged gas/electrics are high efficiency self contained cooling units
More informationPRPHP14 PRODUCT SPECIFICATIONS 14 SEER HEAT PUMP PACKAGED UNIT REFRIGERANT SYSTEM CABINET CONSTRUCTION BLOWER CONTROLS INSTALLATION ACCESSORIES
PRODUCT SPECIFICATIONS 4 SEER HEAT PUMP PACKAGED UNIT FORM NO. -00 (03/207) REFRIGERANT SYSTEM Environmentally friendly R40A refrigerant Copper tubing with enhanced fin coils Internal service gauge ports
More informationPACKAGE GAS / ELECTRIC ROOFTOP UNITS
PACKAGE GAS / ELECTRIC ROOFTOP UNITS FORM NO. R22-842 REV. 1 Supersedes Form No. R22-842 Featuring New Industry Standard R-410A Refrigerant RKNL-B STANDARD EFFICIENCY SERIES NOMINAL SIZES 15-25 TONS [52.8-87.9
More informationGQ4SD Series. Single Packaged Heat Pump 13 SEER TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS
TM TECHNICAL SPECIFICATIONS GQ4SD Series Single Packaged Heat Pump 13 SEER The GQ4 Series single packaged units are high efficiency self contained cooling and heating units that can be installed on a roof
More information14.5 SEER VALUE SERIES CONDENSING UNITS
FORM NO. ATZ-215 Supersedes Form No. ATZ-201 Rev. 1 14.5 SEER VALUE SERIES CONDENSING UNITS Features Painted louvered steel cabinet Easily accessible control box Condenser coils constructed with copper
More informationGR4GA Series Single Packaged Gas/Electric Units
TECHNICAL SPECIFICATIONS GR4GA Series Single Packaged Gas/Electric Units GR4GA 10 SEER, Three Phase, 208/230V, 460V, 575V 3 Ton thru 5 Ton Units The GR4GA Series single packaged gas/electrics are high
More informationAFGP12B. Features. Efficiency: 12 SEER 80% AFUE. Warranty: 10-year limited compressor 10-year limited heat exchanger 5-year limited components
AFGP12B Gas/Electric Package Unit Features Shipped for horizontal applications; easily converted to downshot Side-by-side horizontal discharge Standard thermostatic expansion valve Crimp-Tite weld-free
More informationR6GD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, Three Phase, Packaged Gas/ Electric Units with R-410A 3-5 Ton Units WARRANTY
TECHNICAL SPECIFICATIONS R6GD Series 13 SEER, Three Phase, Packaged Gas/ Electric Units with R-410A 3-5 Ton Units The R6GD Series packaged gas/electrics are high efficiency self contained cooling units
More informationProduct Data. Features/Benefits 50JS SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS)
SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS) Product Data UNIT (50 Hz) Single-packaged Heat Pump for Residential and Light Commercial applications. Features/Benefits One-piece
More informationAIR CONDITIONERS WA14**A SERIES
FORM NO. A66-220 AIR CONDITIONERS Features Outdoor air conditioner designed for ground level or rooftop installations. These units offer comfort and dependability for single, multi-family and light commercial
More informationGPC14H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER
Cooling Capacity: 24,000-57,500 BTU/H H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 5 Airflow Data... 18 Heater Kit
More informationQ6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER
TECHNICAL SPECIFICATIONS Q6SP Series Rev A 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1-2010 These 7½ and 10 ton units are designed specifically
More informationRheem High Efficiency Air Handler
Air Handlers Rheem High Efficiency Air Handler Constant Torque Motor (ECM) Efficiencies up to 14 SEER The RH1T feature a Constant Torque motor (ECM) and a piston refrigerant control for efficient and reliable
More informationRheem Commercial Classic Series Package Gas / Electric Rooftop Unit
Package Gas Electric Rheem Commercial Classic Series Package Gas / Electric Rooftop Unit RKNL-B Standard Efficiency Series Nominal Sizes 15-25 Tons [52.8 & 87.9 kw] ASHRAE 90.1-2007 Compliant Model Energy
More informationP8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units
TECHNICAL SPECIFICATIONS P8SE Series 14 SEER, Single Phase Packaged Air Conditioner 3, 4, 5 Ton Units The P8 Series single packaged air conditioners are high efficiency self contained cooling units that
More informationTECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW
DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW MODELS: D4HH 024 THRU 180 York horizontal ductable air conditioning packages offer a complete line of
More informationTECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS Model PPG1GD Series M1010 Product Line Single Packaged Gas/Electric Units 13 SEER 2-5 Ton Units 10 YEAR WARRANTY WORRY-FREE PERFORMANCE 5 YEAR DEPENDABILITY PROMISE The PPG1GD
More informationP8SE Series. 14 SEER, Three Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units
TECHNICAL SPECIFICATIONS P8SE Series 14 SEER, Three Phase Packaged Air Conditioner 3, 4, 5 Ton Units The P8 Series single packaged air conditioners are high efficiency self contained cooling units that
More informationGQ6SD Series. Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY
TECHNICAL SPECIFICATIONS GQ6SD Series Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units The GQ6 Series single packaged units are high efficiency self contained cooling and heating units that can
More informationCPC Commercial. 7½- to 12½-Ton Three-Phase. up to 11.5 EER. Cooling Capacity: 90, ,000 BTU/h. Packaged Air Conditioners
CPC Commercial Cooling Capacity: 90,000 118,000 BTU/h 7½- to 12½-Ton Three-Phase Packaged Air Conditioners up to 11.5 EER Standard Features R-410A chlorine-free refrigerant High-efficiency scroll compressor
More informationR6GD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, Three Phase, Packaged Gas/Electric Units 3-5 Ton Units
TECHNICAL SPECIFICATIONS R6GD Series 13 SEER, Three Phase, Packaged Gas/Electric Units 3-5 Ton Units The R6GD Series packaged gas/electrics are high efficiency self contained heating and cooling units
More informationP6SD Series Single Packaged Air Conditioning, 13 SEER - R-410A 3, 4, 5 Ton Units
TM TECHNICAL SPECIFICATIONS P6SD Series Single Packaged Air Conditioning, 13 SEER - R-410A 3, 4, 5 Ton Units The P6 Series single packaged air conditioners are high efficiency self contained cooling units
More informationPRPDF14 PRODUCT SPECIFICATIONS 14 SEER DUAL FUEL PACKAGED UNIT REFRIGERANT SYSTEM HEAT EXCHANGER CABINET CONSTRUCTION ACCESSORIES WARRANTY BLOWER
PRODUCT SPECIFICATIONS 14 SEER DUAL FUEL PACKAGED UNIT FORM NO. -100 (01/2017) REFRIGERANT SYSTEM Environmentally friendly R410A refrigerant Copper tubing with enhanced fin coils Internal service gauge
More informationPACKAGE GAS / ELECTRIC ROOFTOP UNITS
PACKAGE GAS / ELECTRIC ROOFTOP UNITS FORM NO. R11-841 REV. 2 Supersedes Form No. R11-841 Rev. 1 Featuring Industry Standard R-410A Refrigerant RKNL-B HIGH EFFICIENCY SERIES NOMINAL SIZES 6-12.5 TONS [21.1-44.0
More informationCONDENSING UNITS UAPC- SERIES. Six Models. Cooling Capacities 23,200 to 56,500 BTU/HR [6.8 kw] to [16.6 kw]
FORM NO. A22-173 REV. 9 Supersedes Form No. A22-173 Rev. 8 CONDENSING UNITS SERIES 14 SEER Models With efficiencies up to 16 SEER in certain matched systems. Nominal Sizes 2 to 5 Tons [7.03 kw] to [17.58
More informationProduct Data /4YCC3018A through 2/4YCC3060A Single Package Convertible Gas/Electric 13 SEER 1½ - 5 Ton, MBTU R-22/R-410A
Product Data 22-1784-01 2/4YCC3018A through 2/4YCC3060A Single Package Convertible Gas/Electric 13 SEER 1½ - 5 Ton, 40-120 MBTU R-22/R-410A Mar. 03, 2006 2006 American Standard inc. All Rights Reserved
More informationPHB SERIES 7-1/2 and 10 TON
PHB SERIES 7-1/2 and 10 TON COMMERCIAL SINGLE PACKAGE HEAT PUMPS COMMERCIAL PACKAGE HEAT PUMP FEATURES Representative photo only, some models may vary in appearance. Rated in accordance with ARI Standard
More informationQ6SD Series 13 SEER, Three Phase, Packaged Heat Pump with R-410A 3-5 Ton Units
TM TECHNICAL SPECIFICATIONS Q6SD Series 13 SEER, Three Phase, Packaged Heat Pump with R-410A 3-5 Ton Units The Q6SD Series packaged units are high efficiency self contained cooling and heating units that
More informationCAC SERIES 12-1/2 Thru 20 Ton
CAC SERIES 12-1/2 Thru 20 Ton SPLIT SYSTEM COMMERCIAL AIR CONDITIONER CONSTRUCTION Triple step pre--painted galvanized steal pre--coated inside and out -- using a polyester top coat, over a urethane primer
More information