HEAT PUMPS UPLB- SERIES. Seven Models
|
|
- Sharleen Thompson
- 6 years ago
- Views:
Transcription
1 FORM NO. P Supersedes Form No. P Rev. 6 HEAT PUMPS UPLB- SERIES Seven Models 11 SEER with efficiencies ranging up to 12 SEER in certain matched systems. Nominal Sizes 1 1 /2 to 5 Tons [5.28 to kw] The Ruud Achiever Series High Efficiency UPLB- Heat Pump Outdoor units can provide year-round heating and cooling comfort for residential, multi-family and light commercial applications. They are designed to operate with Ruud indoor units with cooling and heating capacities certified in compliance with the ARI Certification program. The Ruud UBHC- Air Handler equipped with auxiliary heating elements for supplementary heat was designed especially for use with the UPLB- Heat Pump. Together they provide systems capable of delivering S.E.E.R. as high as 12 and s to The following additional features, plus its energy-saving characteristics, make the UPLB- Heat Pump outdoor unit an excellent choice for new construction or upgrading your present system. Full wrap-around powder-painted louvered grille protects the coil from yard hazards and weather extremes. Air is discharged upward away from bushes and shrubs. The discharge pattern of the top grille provides minimum air restriction, resulting in quiet fan operation. Exclusive Combination Grille/Motor Mount* secures the fan motor to the underside of the discharge grille. The grille protects the motor windings and bearings from rain and snow. All models meet or exceed a 1000-hour salt spray test per ASTM B117 Standard Practice for Operating Salt Spray Testing Apparatus. *Patented. ENER UIDE Seasonal Energy Efficiency Ratio - SEER THIS MODEL USES LESS ENERGY 17.0 CERTIFIED UNDER THE A.R.I. CERTIFICATION PROGRAMA.R.I. STANDARD
2 All controls and compressor are accessible for servicing by removal of the service panel. Drawn Painted Base Pan. ELAND SCROLL COMPRESSOR The Copeland scroll compressor is the key to efficiency for this Ruud model. It s the latest in high-efficiency compressor technology. The advanced scroll compressor offers low noise and vibration characteristics and features tolerance to liquid refrigerant and system contamination. The Copeland Scroll also has low start torque, eliminating start problems in the field. And its unique design enables the UPLB- Heat Pump unit to perform more efficiently. Engineering Features UPLB- Series Remote Heat Pumps 1. Scroll CompressorsIncorporate internal high temperature motor overload protection and durable insulation on the motor windings. They are externally mounted on rubber grommets to reduce vibration and noise. 2. Copper Tube/Aluminum Fin CoilsImproved heat transfer and corrosion resistance. 3. Strong, Attractive CabinetConstructed of powder painted steel providing protection to the condenser coil and a durable finish. 4. Demand Defrost ControlsProvides complete defrost when defrost is required. 5. Non-Cycling Reversing ValveEliminates discharge noises on each heating cycle. 6. Hot Gas MufflerReduces noise in heating cycle. 7. Suction Line AccumulatorProvides protection for the compressor. 8. Service Valves are standard on all models. 9. Refrigerant MeteringFlowcheck distributor. 10. Drawn, painted base pan reduces noise and vibration, and provides extra corrosion resistance. 11. Manual reset high pressure controlstandard. Accessories Low Ambient ControlAllows low temperature operation in the cooling cycle down to 0 F [-17.8 C] outdoor temperature. It is recommended that this control be installed in units to be operated for cooling at outdoor ambient temperatures under 65 F [18 C]. (Model No. RXPZ-C01) Heat Pump MonitorIndicates inefficient operation or malfunction of heat pump. (Model No. RXPM-B01) Outdoor Thermostats RXPT-A01One outdoor thermostat in box. RXPT-A02One outdoor thermostat for mounting in box for use with RXPT-A01 or A03. RXPT-A03One outdoor thermostat with emergency Heat Relay wired and mounted in box. RXPT-A04Two outdoor thermostats with emergency Heat Relay wired and mounted in box. Thermostats and SubbasesAvailable from PROSTOCK. Time Delay ControlCompressor will remain off for five minutes after power or thermostat interruption, allowing system pressures to equalize. Starting during high pressure conditions can result in shortened compressor life. (Model No. RXMD-B01) Blower Time Delay ControlRXMD-C02. Fossil Fuel KitsRXPF-01 RXPF-02 Model Number Identification U P L B 024 J A Z RUUD REMOTE HEAT PUMP HIGH EFFICIENCY (STANDARD) 2 Ruud Manufacturing Air Conditioning Company Division DESIGN SERIES B = SECOND DESIGN COOLING CAPACITY 018 = 18,000 R [5.28 kw] 024 = 24,000 R [7.03 kw] 030 = 30,000 R [8.79 kw] 036 = 3 R [10.55 kw] 042 = 42,000 R [12.31 kw] 048 = 48,000 R [14.07 kw] 060 = 60,000 R [17.58 kw] ELECTRICAL DESIGNATION J = 208/230V-1-60 VARIATIONS A = STANDARD COOLING FITTING Z = SWEAT W/SCROLL [ ] Designates Metric Conversions
3 Performance ARI Standard ConditionsSingle Phase Note: Only these combinations of indoor/outdoor units are approved and any other combinations should not be used. Outdoor Unit UPLB- 018JA 024JA 030JA RCHA-24A1 Model Numbers Coil and/or Air Handler RCBA-2457+RXCT-CHA RCBA-2457+RXCT-CHA+RXMD-C02 RCHA-24A1+RXMD-C02 UBHC-14+RCBA-2457+RXCT-CHA UBHC-14+RCBA-2457+RXCT- CHA+RXMD-C02 UBHC-14+RCHA-24A1 UBHC-14+RCHA-24A1+RXMD-C02 UBHC-15+RCBA-2457+RXCT-CHA UBHC-15+RCBA-2457+RXCT- CHA+RXMD-C02 UBHC-15+RCHA-24A1 UBHC-15+RCHA-24A1+RXMD-C02 UBHK-17+RCHA-24A1 RCBA-2457+RXCT-CHB RCBA-2457+RXCT-CHB+RXMD-C02 RCHA-24A2 ➀ RCHA-24A2+RXMD-C02 UBHC-14+RCBA-2457+RXCT-CHB UBHC-14+RCBA-2457+RXCT- CHB+RXMD-C02 UBHC-14+RCHA-24A2 UBHC-14+RCHA-24A2+RXMD-C02 UBHC-15+RCBA-2457+RXCT-CHB UBHC-15+RCBA-2457+RXCT- CHB+RXMD-C02 UBHC-15+RCHA-24A2 UBHC-15+RCHA-24A2+RXMD-C02 UBHK-17+RCHA-24A2 RCBA-3765+RXCT-CHC RCBA-3765+RXCT-CHC+RXMD-C02 RCHA-36A1 ➀ RCHA-36A1+RXMD-C02 Capacity 17, 17, 17, 17, 18,200 [5.3] 22, [6.6] 22, [6.6] 22, [6.6] 22, [6.6] 22, 22, 22, 22, 22, 22, 22, 22, 23,400 27, 27, 27, 27, ARI Cooling Performance 80 F [26.5 C] DB/67 F [19.5 C] WB Air 95 F [35 C] DB Net Net Sens. Latent EER SEER Snd. Rate 12, [3.7] 12, [3.7] 12, [3.7] 12, [3.7] 13,400 [3.9] 1 [4.7] 1 [4.7] 1 [4.7] 1 [4.7] 16, 16, 16, 16, 16, 16, 16, 16, 17,400 [5.1] 20,100 [5.9] 20,100 [5.9] 20,100 [5.9] 20,100 [5.9] 5,200 [1.5] 5,200 [1.5] 5,200 [1.5] 5,200 [1.5] 4, 4, 4, 4, 4, 4, 4, 4, 4, 6, [1.9] 6, [1.9] 6, [1.9] 6, [1.9] 7,700 [2.3] 7,700 [2.3] 7,700 [2.3] 7,700 [2.3] ARI Heating Performance (70 F [21 C] ) 17 F [ 8.5 C] DB/ 15 F [ 9.5 C] WB Low Temp. 47 F [8.5 C] DB/ 43 F [6 C] WB High Temp. ➀ Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions CFM [L/s] 19,500 19,500 19,500 19,500 18, [5.5] 24,400 24,400 24,400 24,400 23, 23, 23, 23, 23, 23, 23, 23, 23,200 [6.8] 1, ,900 1, ,900 1, ,900 1, ,900 11, 1, , , 1, , 1, , 1, , 1, , 1, , 11, 1, , ,300 [3.3] 2, , 2, , 14, 2, , , 15,300 2, ,300 2, , ,700 2, ,400 2, ,400 2, ,400 2, ,400 IV V 1, , , , ,601 1, , , , , , , , , , , , , Ruud Air Conditioning Division 3
4 Performance ARI Standard ConditionsSingle Phase (cont.) Note: Only these combinations of indoor/outdoor units are approved and any other combinations should not be used. 030JA 036JA 042JA Model Numbers Coil and/or Air Handler UBHC-17+RCBA-3765+RXCT-CHC UBHC-17+RCBA-3765+RXCT- CHC+RXMD-C02 UBHC-17+RCHA-36A1 UBHC-17+RCHA-36A1+RXMD-C02 UBHC-18+RCBA-3765+RXCT-CHC UBHC-18+RCBA-3765+RXCT- CHC+RXMD-C02 UBHC-18+RCHA-36A1 UBHC-18+RCHA-36A1+RXMD-C02 UBHK-21+RCHA-36A1 RCBA-3765+RXCT-CHK RCBA-3765+RXCT-CHK+RXMD-C02 RCHA-36A2 ➀ RCHA-36A2+RXMD-C02 UBHC-17+RCBA-3765+RXCT-CHK UBHC-17+RCBA-3765+RXCT- CHK+RXMD-C02 UBHC-17+RCHA-36A2 UBHC-17+RCHA-36A2+RXMD-C02 UBHC-18+RCBA-3765+RXCT-CHK UBHC-18+RCBA-3765+RXCT- CHK+RXMD-C02 UBHC-18+RCHA-36A2 UBHC-18+RCHA-36A2+RXMD-C02 UBHK-21+RCHA-36A2 RCBA-4882+RXCT-CHL RCBA-4882+RXCT-CHL+RXMD-C02 RCHA-48A1 ➀ RCHA-48A1+RXMD-C02 UBHC-21+RCBA-4882+RXCT-CHL Outdoor Unit UPLB- UBHC-21+RCBA-4882+RXCT- CHL+RXMD-C02 UBHC-21+RCHA-48A1 UBHC-21+RCHA-48A1+RXMD-C02 Capacity 27, 27, 27, 27, 27, 27, 27, 27, 33,200 ARI Cooling Performance 80 F [26.5 C] DB/67 F [19.5 C] WB Air 95 F [35 C] DB Net Net Sens. Latent EER SEER Snd. Rate 2 [6.2] 23, 23, 23, 23, 23,700 28,000 [8.2] 28,000 [8.2] 28,000 [8.2] 28,000 [8.2] 9,400 9,400 9,400 9,400 8, 8, 8, 8, 8, 8, 8, 8, 9,500 1 [3.2] 1 [3.2] 1 [3.2] 1 [3.2] 10, 10, 10, 10, ARI Heating Performance (70 F [21 C] ) 17 F [ 8.5 C] DB/ 15 F [ 9.5 C] WB Low Temp. 47 F [8.5 C] DB/ 43 F [6 C] WB High Temp. ➀ Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions CFM [L/s] ,400 [7.7] 34,200 [10.0] 34,200 [10.0] 34,200 [10.0] 34,200 [10.0] 34, 34, 34, 34, 34, 34, 34, 34, 33,200 18,400 2, , , , 3, , 21, 3, , , 3, , 3, , 21, 3, , , 3, , 3, , 21, 3, , , 3, [6.2] 4, , [7.5] 25, 4, [7.5] 4, , [7.5] 4, , [7.5] 3, , 3, , 3, , 3, , IV V 2,324 2, , , , , , , , , , , , Ruud Air Conditioning Division
5 Performance ARI Standard ConditionsSingle Phase (cont.) Note: Only these combinations of indoor/outdoor units are approved and any other combinations should not be used. 042JA 048JA 060JA Model Numbers Coil and/or Air Handler UBHC-22+RCBA-4882+RXCT-CHL UBHC-22+RCBA-4882+RXCT- CHL+RXMD-C02 UBHC-22+RCHA-48A1 UBHC-22+RCHA-48A1+RXMD-C02 UBHK-24+RCHA-48A1 RCBA-4882+RXCT-CHL RCBA-4882+RXCT-CHL+RXMD-C02 RCHA-48A1 ➀ RCHA-48A1+RXMD-C02 UBHC-21+RCBA-4882+RXCT-CHL UBHC-21+RCBA-4882+RXCT- CHL+RXMD-C02 UBHC-21+RCHA-48A1 UBHC-21+RCHA-48A1+RXMD-C02 UBHC-22+RCBA-4882+RXCT-CHL UBHC-22+RCBA-4882+RXCT- CHL+RXMD-C02 UBHC-22+RCHA-48A1 UBHC-22+RCHA-48A1+RXMD-C02 UBHK-24+RCHA-48A1 RCBA-6089+RXCT-CHM+RXMD-C02 RCHA-60A1+RXMD-C02 ➀ UBHC-24+RCBA-6089+RXCT-CHM UBHC-24+RCBA-6089+RXCT- CHM+RXMD-C02 UBHC-24+RCHA-60A1 UBHC-24+RCHA-60A1+RXMD-C02 UBHC-26+RCBA-6089+RXCT-CHM Outdoor Unit UPLB- UBHC-26+RCBA-6089+RXCT- CHM+RXMD-C02 UBHC-26+RCHA-60A1 UBHC-26+RCHA-60A1+RXMD-C02 UBHK-25+RCHA-60A1 Capacity 4 [13.5] 4 [13.5] 4 [13.5] 4 [13.5] 46,500 [13.6] 53,500 [15.7] 53,500 [15.7] 53,500 [15.7] 53,500 [15.7] ARI Cooling Performance 80 F [26.5 C] DB/67 F [19.5 C] WB Air 95 F [35 C] DB Net Sens. EER SEER Snd. Rate 29,400 [8.6] 32,000 [9.4] 32,000 [9.4] 32,000 [9.4] 32,000 [9.4] 33,500 40,400 [11.8] 40,400 [11.8] 40,400 [11.8] 40,400 [11.8] Net Latent 10, 10, 10, 10, 10, 13, 13, 13, 13, ARI Heating Performance (70 F [21 C] ) 17 F [ 8.5 C] DB/ 15 F [ 9.5 C] WB Low Temp. 47 F [8.5 C] DB/ 43 F [6 C] WB High Temp. ➀ Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions CFM [L/s] 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 2,000 [944] 2,000 [944] 1,925 [908] 1,925 [908] 1,925 [908] 1,925 [908] 1,825 [861] 1,825 [861] 1,825 [861] 1,825 [861] 2,000 [944] 39,500 [11.6] 5 [14.9] 5 [14.9] 5 [14.9] 5 [14.9] 49,000 [14.4] 57,000 [16.7] 57,000 [16.7] 3, , 3, , 3, , 3, , 25, 3, [7.6] 5, , 5, , 5, , 5, , 4, , 4, , 33, 4, , , 4, , 4, , 33, 4, , , 4, , [9.6] 5, ,000 [10.8] 37,000 5, [10.8] 5, , [10.7] 5, , [10.7] 5, , [10.7] 36, 5, [10.7] 36,200 5, [10.6] 5, ,200 [10.6] 5, ,200 [10.6] 5, ,200 [10.6] 4, , [10.4] IV V 3,177 4, , , , , , , , , , , , , , , , , , Ruud Air Conditioning Division 5
6 Unit Dimensions AIR DISCHARGE ALLOW [1524 mm] CLEARANCE W L H ACCESS PANEL AIR INLETS (LOUVERS) ALLOW 120 [305 mm] MIN. CLEARANCE 3 SIDES A ALLOW 240 [610 mm] ACCESS CLEARANCE LOW VOLTAGE 7/80 [22 mm] SERVICE FITTINGS HIGH VOLTAGE 1 11 /320 [34 mm] A HIGH PRESSURE CONTROL MANUAL RESET (FIELD INSTALLED ACCESSORY) VAPOR LINE 2 7 /80 [73 mm] DIA. ACCESSORY KNOCKOUTS LIQUID LINE SERVICE ACCESS TO ELECTRICAL & VALVES ALLOW 240 [610 mm] CLEARANCE ONE SIDE A Dimensions Heat Pump Model UPLB- 018, 024, , , 060 Height H (Inches) [mm] 19" 3/4[482.60] 25" [635] Length L (Inches) [mm] 40 1 /2" [ ] 44 3 /8"6 [ ] Width W (Inches) [mm] 27 5 /8" [701.67] 31 1 /2"6 [.10] Length LS of Stand (Inches) [mm] /32" [711] /32" [834.23] Length LP of Pump-Ups (Inches) [mm] 28 5 /16" [719.14] 32 1 /32" [813.59] BOTTOM VIEW SHOWING DEFROST CONDENSATE DRAIN OPENINGS (\\\\\\ SHADED AREAS). [ ] Designates Metric Conversions 6 Ruud Air Conditioning Division
7 Electrical and Physical Data Model No. UPLB- Phase Hertz Volts Compr. RLA Compr. LRA ELECTRICAL Fan Motor FLA Min. Cir. Ampacity Amps Fuse or HACR Circuit Breaker Min. Amps Max. Amps Face Area Sq. Ft. [m 2 ] Outdoor Coil PHYSICAL 018JA / /13 20/20 20/ [1.02] [1090] 72 [2041] 160 [72.6] 170 [77.1] 024JA / /18 25/25 30/ [1.02] [1090] 72 [2041] 155 [70.3] 165 [74.8] 030JA / /19 25/25 30/ [1.02] [1090] 77 [2183] 155 [70.3] 165 [74.8] 036JA / /23 30/30 40/ [1.60] [1392] 135 [3827] 200 [90.7] 210 [95.3] 042JA / /27 35/35 45/ [1.60] 1 3 [1700] 116 [3289] 205 [93.0] 215 [97.5] 048JA / /35 45/45 60/ [1.56] [1605] 192 [5443] 245 [111.1] 255 [115.7] 060JA / /38 45/45 60/ [1.56] [1605] 192 [5443] 275 [124.7] 285 [129.3] No. Rows CFM [L/s] R22 Oz. [g] Net Lbs. [kg] Weight Shipping Lbs. [kg] Refrigerant Metering Metering Device RCHA- Coils Coil Size TX Valve Metering Code A1 A2 A1 A2 A1 A1 Valve Size (Ton) 1 1 /2 [5.28] 2 [7.03] 2 1 /2 [8.79] 3 [10.55] 3 1 /2 [12.31] & 4 [14.07] 5 [17.58] Piston Size [ ] Designates Metric Conversions GENERAL TERMS OF LIMITED WARRANTY Ruud will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty. For Complete Details of the Limited Warranty, Including Applicable Terms and Conditions, See Your Local Installer or Contact the Manufacturer for a Copy. Condenser Coil leaks caused by factory defects...five (5) Years Compressor...Ten (10) Years *Any Other Part...Five (5) Years *This five year limited warranty is applicable only to single-phase products installed in residential applications on or after January 1, BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE FROM YOUR RETAILER. Ruud Air Conditioning Division 7
8 Heat Pump Refrigerant Line Size Information System Capacity Model Liquid Line Size Liquid Line Size Line Outdoor Unit Above Coil Outdoor Unit Below Coil Size LengthFeet [m] LengthFeet [m] (Inch O.D.) [mm] 25 [7.62] 50 [15.24] 75 [22.86] 100 [30.48] 125 [38.10] 150 [45.72] 25 [7.62] 50 [15.24] 75 [22.86] 100 [30.48] 125 [38.10] 150 [45.72] Vertical SeparationFeet [m] Vertical SeparationFeet [m] 1/4* [6.35] 25 [7.62] 50 [15.24] 70 [21.34] 25 [7.62] 23 [7.01] 8 [2.44] 5/16 [7.94] 36 [10] 42 [12.80] 48 [14.63] 54 [16.46] /4* [6.35] 25 [7.62] 50 [15.24] 25 [7.62] 23 [7.01] 5/16 [7.94] 24 [7.32] 34 [10.36] 44 [13.41] 54 [16.46] 64 [19.51] /4* [6.35] 25 [7.62] 50 [15.24] 25 [7.62] 23 [7.01] 5/16 [7.94] 19 [5.79] 33 [10.06] 47 [14.33] 61 [18.59] /8 [9.53] 11 [3.35] 15 [4.57] 0 5/16* [7.94] 25 [7.62] 50 [15.24] 70 [21.34] 25 [7.62] 23 [7.01] 9 [2.74] 3/8 [9.53] 34 [10.36] 40 [12.19] 46 [14.02] 52 [15.85] /16* [7.94] 25 [7.62] 50 [15.24] 75 [22.86] 25 [7.62] 23 [7.01] 9 [2.74] 3/8 [9.53] 32 [9.75] 39 [11.89] 46 [14.02] 53 [16.15] /8* [9.53] 25 [7.62] 44 [13.41] 53 [16.15] 61 [18.59] 70 [21.34] 25 [7.62] 28 [8.53] 19 [5.79] 11 [3.35] 3 [.91] 1/2 [12.7] 37 [11.28] 39 [11.89] 0 0 3/8* [9.53] 25 [7.62] 48 [14.63] 61 [18.59] 72 [21.95] 25 [7.62] 23 [7.01] 11 [3.35] 3 [.91] 1/2 [12.7] 35 [10.67] 38 [11.58] 41 [12.50] *Standard line size NOTES: ➀ This chart is applicable for heat pumps. ➁ If the separation height exceeds the table values, increase the outdoor flow-check piston two sizes plus one size for each additional 10 feet [3.05 m]. Example 1: A 5 ton [17.58 kw] heat pump with a total line length of 100 feet [30.48 m] with a vertical separation of 93 feet [28.35 m] utilizing a 3 /8" [9.53 mm] liquid line: Table = 72 feet [21.95 m] maximum vertical separation for 100 feet [30.48 m] run. Separation exceeds table by (93-72) = 21 feet [6.40 m]. Therefore, reduce the indoor coil flow-check piston = 4 sizes (For example, a #89 piston would reduce to a #85 piston). Increase the outdoor flow-check piston = 4 sizes (For example, a #56 would increase to a #60). ➂ Do not exceed 120 feet [36.58 m] maximum vertical separation. ➃ No changes are required for expansion valve coils. ➄ Do not exceed table values for capillary tube coils. ➅ Always use the smallest liquid line possible to minimize system charge. ➆ For heat pumps with vertical separation: Route liquid line outside building Do not insulate liquid line. ➇ Chart may be used to size horizontal runs. NOTES: ➀ This chart is applicable for heat pumps. Heat pumps with any vertical separation require the use of standard line sizes only, due to the possibility of charge imbalance between heating and cooling modes. Example 1: A 3 ton [10.55 kw] heat pump with a total line length of 50 feet [15.24 m] can have a maximum vertical separation of 19 feet [5.79 m]. Do not increase line size to 3 /8" [9.53 mm]. ➁ This chart may also be used to size horizontal runs. Example 2: A 1.5 ton [5.28 kw] heat pump can have a total horizontal line length of 150 feet [45.72 m] when using the 5 /16" [7.94 mm] liquid line size. No vertical separation allowed. ➂ Do not exceed vertical separation as indicated on the chart. ➃ Always use the smallest liquid line possible to minimize system charge. ➄ No changes required for flow-check pistons or expansion valve coils. UPLB Unit Vapor Line Connection Size Vapor Line RunFeet [m] 25' [7.62] 50' [15.24] 100' [30.48] 150' [45.72] Standard Standard Standard Standard Vapor Line Length/Size versus Capacity Multiplier /4" [19.05 mm] 7/8" [22.23 mm] 1 1 /8" [28.58 mm} I.D. Sweat I.D. Sweat I.D. Sweat 5/8" [15.88 mm] O.D. 3/4" [19.05 mm] O.D. 7/8" [22.23 mm] O.D. 3/4" [19.05 mm] O.D. Standard 7/8" [22.23 mm] O.D. Standard 1 1 /8" [28.58 mm] O.D. Standard 7/8" [22.23 mm] O.D. 1 1 /8" [28.58 mm] O.D. 1 3 /8" [34.94 mm] O.D. 5/8" [15.88 mm] I.D. Sweat 5/8" [15.88 mm] O.D. Standard 3/4" [19.05 mm] O.D NOTES: Capacity Multiplier x Rated Capacity = Actual Capacity. Additional compressor oil is not required for runs up to 150 feet [45.72 m]. Oil traps in vertical runs are not required for any height up to 100 feet [30.48 m]. See Liquid Line chart for Vertical Separation Requirements and Limitations [ ] Designates Metric Conversions Before proceeding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal, State, Provincial, and Local codes, regulations, and practices. RUUD AIR CONDITIONING DIVISION 5 Old Greenwood Road, Fort Smith, Arkansas In keeping with its policy of continuous progress and product improvement, Ruud reserves the right to make changes without notice. PRINTED IN U.S.A DC FORM NO. P22-755
HEAT PUMPS UPKB- SERIES. Seven Models
FORM NO. P22-754 REV. 1 Supersedes Form No. P11-729 Rev. 8 HEAT PUMPS UPKB- SERIES Seven Models 10 SEER with efficiencies ranging up to 10.30 SEER in certain matched systems. Nominal Sizes 1 1 /2 to 5
More informationHEAT PUMPS CLASSIC X HEAT PUMPS RPKA- SERIES. Nominal Sizes 1 1 /2 to 5 Tons [5.28 to kw]
FORM NO. P11-729 REV. 6 Supersedes Form No. P11-729 Rev. 5 HEAT PUMPS CLASSIC X HEAT PUMPS RPKA- SERIES Nominal Sizes 1 1 /2 to 5 Tons [5.28 to 17.58 kw] The Rheem RPKA- Heat Pump Outdoor units can provide
More informationCONDENSING UNITS RAKB- SERIES. Seven Models
FORM NO. A11-168 REV. 2 Supersedes Form No. A11-168 Rev. 1 Supersedes Form No. A11-147 Rev. 8 CONDENSING UNITS SERIES Nominal Sizes 1 1 /2 to 5 Tons [5.28 kw] to [17.58 kw] Seven Models 10 SEER with efficiencies
More informationCONDENSING UNITS CLASSIC X CONDENSING UNITS RAKA- SERIES. Seven Models. Cooling Capacities 17,000 to 56,500 BTU/HR [4.98 kw] to [16.
FORM NO. A11-147 REV. 9 Supersedes Form No. A11-147 Rev. 8 CONDENSING UNITS CLASSIC X CONDENSING UNITS Seven Models Cooling Capacities 17,000 to 56,500 BTU/HR [4.98 kw] to [16.56 kw] SERIES Nominal Sizes
More informationCONDENSING UNITS ACHIEVER 12 SUPER HIGH EFFICIENCY CONDENSING UNITS UAMA- SERIES. Seven Models
FORM NO. A22-149 REV. 6 Supersedes Form No. A22-149 Rev. 5 CONDENSING UNITS ACHIEVER 12 SUPER HIGH EFFICIENCY CONDENSING UNITS SERIES Nominal Sizes 1 1 /2 to 5 Tons [5.28 kw] to [17.58 kw] Seven Models
More informationCONDENSING UNITS UAPC- SERIES. Six Models. Cooling Capacities 23,200 to 56,500 BTU/HR [6.8 kw] to [16.6 kw]
FORM NO. A22-173 REV. 9 Supersedes Form No. A22-173 Rev. 8 CONDENSING UNITS SERIES 14 SEER Models With efficiencies up to 16 SEER in certain matched systems. Nominal Sizes 2 to 5 Tons [7.03 kw] to [17.58
More information13 SEER HEAT PUMPS Features Coils constructed with copper tubing and enhanced aluminum
FORM NO. P22-5 REV. 7 Supersedes Form No. P22-5 Rev. 6 13PJA SERIES 13 SEER HEAT PUMPS Features Coils constructed with copper tubing and enhanced aluminum fins. Strong, attractive cabinetlouvered design
More information13 SEER HEAT PUMPS Features Coils constructed with copper tubing and enhanced aluminum
FORM NO. P66-774 Supersedes Form No. P66-765 Rev. 4 Featuring Earth-Friendly R-410A Refrigerant 13PJL SERIES earth friendly refrigerant 13 SEER HEAT PUMPS Features Coils constructed with copper tubing
More information13 SEER HEAT PUMPS Features Coils constructed with copper tubing and enhanced aluminum
FORM NO. P11-5 REV. 6 Supersedes Form No. P11-5 Rev. 5 13PJA SERIES 13 SEER HEAT PUMPS Features Coils constructed with copper tubing and enhanced aluminum fins. Strong, attractive cabinetlouvered design
More information14.5 SEER HEAT PUMPS. Featuring New Industry Standard R-410A Refrigerant TZPL SERIES
FORM NO. PTZ-781 Supersedes Form No. PTZ-781 Featuring New Industry Standard R-410A Refrigerant TZPL SERIES Manufactured for Thermal Zone Philadelphia, PA (IN CERTAIN MATCHED SYSTEMS) 14.5 SEER HEAT PUMPS
More information14.5 SEER HEAT PUMPS. Featuring Industry Standard R-410A Refrigerant TZPL SERIES. Features Coils constructed with copper tubing and enhanced aluminum
FORM NO. PTZ-803 Supersedes Form No. PTZ-781 Featuring Industry Standard R-410A Refrigerant TZPL SERIES Efficiencies up to 14.5 SEER/12.00 EER/8.50 HSPF Nominal Sizes 1.5 to 5 Tons [5.28 kw] to [17.6 kw]
More informationRuud Achiever Series Heat Pumps
16.0 Heat Pumps Ruud Achiever Series Heat Pumps Efficiencies up to 15.5 S/13 /10.00 Nominal Sizes 1.5 to 5 Ton [5.28 to 17.6 kw] Proper sizing and installation of equipment is critical to achieve optimal
More information13 SEER CONDENSING UNITS
FORM NO. ATZ-218 REV. 1 Supersedes Form No. ATZ-205 Featuring Industry Standard R-410A Refrigerant 13 SEER CONDENSING UNITS Features Painted louvered steel cabinet. Easily accessible control box. Condenser
More informationRuud Achiever Series Heat Pumps
16.0 Heat Pumps Series Ruud Achiever Series Heat Pumps Series Efficiencies up to 14.50 SEER/12.00 EER/9.50 HSPF Nominal Sizes 2 to 5 Ton [7.03 to 17.6 kw] Proper sizing and installation of equipment is
More information14.5 SEER VALUE SERIES CONDENSING UNITS
FORM NO. ATZ-215 Supersedes Form No. ATZ-201 Rev. 1 14.5 SEER VALUE SERIES CONDENSING UNITS Features Painted louvered steel cabinet Easily accessible control box Condenser coils constructed with copper
More informationAIR CONDITIONERS WA14**A SERIES
FORM NO. A66-220 AIR CONDITIONERS Features Outdoor air conditioner designed for ground level or rooftop installations. These units offer comfort and dependability for single, multi-family and light commercial
More informationINDOOR COILS RCBA-/RCHJ-/RCHL- MULTIFLEX CASED OR UNCASED INDOOR COILS. AIRFLOW CAPACITIES CFM [ L/s]
FORM NO. C11-206 REV. 13 Supersedes Form No. C11-206 Rev. 12 INDOOR S RCBA-/RCHJ-/RCHL- MULTIFLEX CASED OR UNCASED INDOOR S AIRFLOW CAPACITIES 600-2000 CFM [218-944 L/s] Rheem Indoor Coils are designed
More information15 SEER HEAT PUMPS. Featuring New Industry Standard R-410A Refrigerant 15PJL SERIES
FORM NO. P11-789 REV. 1 Supersedes Form No. P11-789 Featuring New Industry Standard R-410A Refrigerant SERIES (IN CERTAIN MATCHED SYSTEMS) Visit www.rheem.com for complete details. 15 S HEAT PUMPS Features
More informationRheem Prestige Series Heat Pumps equipped with the Comfort Control System
15.5 Air Heat Pumps Rheem Prestige Series Heat Pumps equipped with the Comfort Control System Efficiencies up to 15.5 /13.0 /9.5 Nominal Sizes 1.5 to 5 Ton [5.28 to 17.6 kw] Proper sizing and installation
More informationAIR HANDLERS RBHC- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT
FORM NO. H11-517 REV. 1 Supersedes Form No. H11-509 Rev. 7 AIR HANDLERS RBHC- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT Features 1 1 /2 ton [5.3 kw] through 5 ton [17.6 kw] models are always just
More informationINDOOR COILS RCBA-/RCHJ-/RCHL- MULTIFLEX CASED OR UNCASED INDOOR COILS. AIRFLOW CAPACITIES CFM [ L/s]
FORM NO. C22-206 REV. 14 Supersedes Form No. C22-206 Rev. 13 INDOOR S RCBA-/RCHJ-/RCHL- MULTIFLEX CASED OR UNCASED INDOOR S AIRFLOW CAPACITIES 600-2000 CFM [218-944 L/s] Ruud Indoor Coils are designed
More informationHEAT PUMPS. Equipped with the Award Winning Comfort Control System RPRL- JEZ. Two-Stage Four Models
FORM NO. P-770 REV. 5 Supersedes Form No. P-770 4 HEAT PUMPS Equipped with the Award Winning Comfort Control System Increased Reliability On-Board Diagnostics Fault Recall Active Protection JEZ Two- Four
More informationDS4BD-KB Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Air Conditioner 13 SEER Residential System 1.
TECHNICAL SPECIFICATIONS DS4BD-KB Series R-410A High Efficiency Air Conditioner 13 SEER Residential System 1.5 5 Ton Capacity The DS4BD-KB Series now offers the choice of an air conditioner that uses a
More informationAIR CONDITIONERS WA16 SERIES
FORM NO. A66-222 AIR CONDITIONERS Features Outdoor air conditioner designed for ground level or rooftop installations. These units offer comfort and dependability for single, multi-family and light commercial
More informationAIR HANDLERS AIR HANDLERS. UHKA- SERIES featuring R-22 Refrigerant UHKL- SERIES featuring Earth-Friendly R-410A Refrigerant.
FORM NO. H22-523 REV. 4 Supersedes Form No. H22-523 Rev. 3 AIR HANDLERS AIR HANDLERS UHKA- SERIES featuring R-22 Refrigerant UHKL- SERIES featuring Earth-Friendly R-410A Refrigerant Features earth friendly
More informationAIR HANDLERS RBHK- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT
FORM NO. H11-516 REV. 1 Supersedes Form No. H11-516 Rev. 0 AIR HANDLERS RBHK- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT Features Versatile 4-way convertible design for upflow, downflow, horizontal
More informationRCBA- MULTIFLEX INDOOR COILS
FORM NO. C11-207 REV. 3 Supersedes Form No. C11-207 Rev. 2 RCBA- MULTIFLEX INDOOR S AIRFLOW CAPACITIES 600-2000 CFM [218-944 L/s] Rheem Value Series Indoor Coils are designed for use with Rheem Value Series
More informationVT4BF-KA/B Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Ultra High Efficiency Heat Pump 16 SEER Residential System 2-5 Ton Capacity
TECHNICAL SPECIFICATIONS VT4BF-KA/B Series Ultra High Efficiency Heat Pump 16 SEER Residential System 2-5 Ton The VT4BF-KA/B series now offers the choice of a heat pump that uses a more efficient and environmentally
More informationFS5BD-KA Series High Efficiency Air Conditioner 13+ SEER Residential System Ton Capacity
TECHNICAL SPECIFICATIONS FS5BD-KA Series High Efficiency Air Conditioner 13+ SEER Residential System 1.5-5 Ton Capacity The FS5BD Series of air conditioners offers exceptional performance. The unit, when
More informationRheem Prestige Series Heat Pumps Equipped with The Comfort Control 2. System
16.0 Air Heat Pumps Rheem Prestige Series Heat Pumps Equipped with The Comfort Control 2 System Series Efficiencies Ranging to 17 SEER/13 EER/9.5 Nominal Sizes 2 to 5 Ton [7.03 to 17.6 kw] Proper sizing
More informationJT4BD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 13 SEER Residential System Ton Capacity WARRANTY
TECHNICAL SPECIFICATIONS JT4BD Series R-410A High Efficiency Heat Pump 13 SEER Residential System 1.5 5 Ton Capacity The JT4BD Series now offers the choice of a heat pump that uses a more efficient and
More informationHEAT PUMP AIR HANDLERS AND FAN COIL UNIT
FORM NO. H66-515 Supersedes Form No. H66-5 Rev. 1 HEAT PUMP AIR HANDLERS AND FAN COIL UNIT Features 1 1 /2 ton [5 kw] through 5 ton [18 kw] models are always just 35 inches [889 mm] tall and 22 inches
More informationN4A6. Product Specifications
ENVIRONMENTALLY SOUND REFRIGERANT N4A6 Product Specifications EFFICIENT UP TO 16.5 SEER/12.2 13.0 EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/2 Volt,
More informationTECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS Model MSA(4,6)BF Series M120 Product Line Extra High Efficiency Air Conditioner 16 SEER 2-5 Ton Capacity 2 The MSA(4,6)BF Series of Maytag air conditioners offers exceptional performance.
More informationAIR HANDLERS AIR HANDLERS. RHPN- SERIES 18 SEER featuring Earth-Friendly R-410A Refrigerant. Features
FORM NO. H11-528 Supersedes Form No. H11-526 Rev. 1 AIR HANDLERS AIR HANDLERS RHPN- SERIES 18 SEER featuring Earth-Friendly R-410A Refrigerant Features earth friendly refrigerant Includes an energy efficient
More informationHCH6. Product Specifications
HCH6 Product Specifications HIGH EFFICIENCY 16 SEER TWO- STAGE HEAT PUMP WITH OBSERVERt COMMUNICATING CONTROL SYSTEM 2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Copeland
More informationET4BE Series R-410A High Efficiency Heat Pump 14 SEER Residential System 1 1/2 5 Ton Capacity
TECHNICAL SPECIFICATIONS ET4BE Series R-410A High Efficiency Heat Pump 14 SEER Residential System 1 1/2 5 Ton Capacity ET4BE Series now offers the choice of a heat pump that uses a more efficient and environmentally
More informationRheem Value Series Two-Stage Air Conditioners
16.0 Air Air Conditioners Rheem Value Series Two- Air Conditioners Series Efficiencies up to 16 SEER/13 EER Nominal Sizes 2-5 Ton [7.03 to 17.6 kw] Cooling Capacities 25,400 to 57,000 BTU/H [7.44 to 16.70
More informationVS6BF Series 2-4 Ton Capacity. VS4BF Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 5 Ton Capacity
TECHNICAL SPECIFICATIONS VS6BF Series 2-4 Ton Capacity VS4BF Series 5 Ton Capacity The VS(4,6)BF Series now offers the choice of an air conditioner that uses a more efficient and environmentally friendly
More informationTECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:
036-21323-001-B-0202 GENERAL SPECIFICATIONS OUTDOOR UNIT: Two independent refrigerant circuits Inherently protected fan motors Two independent scroll compressors V-Coil Design Exterior service port connections
More informationAIR HANDLERS UBHN- SERIES AIR HANDLERS AND FAN COIL UNIT PRELIMINARY NOT FOR DISTRIBUTION
FORM NO. H22-522 AIR HANDLERS earth friendly refrigerant PRELIMINARY NOT FOR DISTRIBUTION UBHN- SERIES AIR HANDLERS AND FAN COIL UNIT Features Versatile 3-way convertible design for upflow, horizontal
More informationS5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS
TECHNICAL SPECIFICATIONS S5BP Series Split System Air Conditioner 71/2 Ton Energy Star rated at 11.7 EER and 11.8 IEER 10 Ton rated at 11.2 EER and 11.5 IEER R-410A Refrigerant The S5BP Series of air conditioners
More informationDESCRIPTION FEATURES
SPLIT-SYSTEM AIR COOLED CONDENSING UNIT H5CE150, H5CE180 AND H5CE240 12-1/2, 15 AND 20 NOMINAL TONS (World 50Hz) DESCRIPTION These outdoor condensing units are completely assembled, piped and wired at
More informationJT4BD Series 13 SEER TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, 8.0 HSPF 3 Phase Light Commercial High Efficiency, Heat Pump
TECHNICAL SPECIFICATIONS JT4BD Series 13 SEER 13 SEER, 8.0 HSPF 3 Phase Light Commercial High Efficiency, Heat Pump 3, 4, 5 Ton Capacities The JT4BD Series heat pump, when combined with our engineered
More informationS3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant
TECHNICAL SPECIFICATIONS S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant The S3BN Series of air conditioners offers exceptional performance from
More informationVS4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Air Conditioner. 14 SEER Residential System 1.
TECHNICAL SPECIFICATIONS VS4BE Series R-410A High Efficiency Air Conditioner 14 SEER Residential System 1.5 5 Ton Capacity The VS4BE Series now offers the choice of an air conditioner that uses a more
More informationFORM NO. PTZ-806 REV. 1 HEAT PUMPS
FORM NO. PTZ-806 REV. 1 TZPLS-14 SERIES Efficiencies: 15 SEER/12.5 EER 9 HSPF Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7 kw] Manufactured for Thermal
More informationTSA6. Product Specifications. SmartComfort TXC 5600
ENVIRONMENTALLY SOUND REFRIGERANT TSA6 SmartComfort TXC 5600 Product Specifications 16 SEER SINGLE STAGE AIR CONDITIONER WITH OBSERVER COMMUNICATING CONTROL SYSTEM 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230
More informationVT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 14 SEER Residential System Ton Capacity WARRANTY
TECHNICAL SPECIFICATIONS VT4BE Series R-410A High Efficiency Heat Pump 14 SEER Residential System 1.5 5 Ton Capacity The VT4BE Series now offers the choice of a heat pump that uses a more efficient and
More informationPackage Air Conditioners
MODEL: RACA14 Package Air Conditioners FORM NO. SSC-969 REV. 1 Sure Comfort RACA14 Package Air Conditioners RACA14 14 SEER Nominal Sizes 2-5 Tons [7.0-17.6 kw] Proper sizing and installation of equipment
More informationJS6BD-K Builder's Series
TECHNICAL SPECIFICATIONS JS6BD-K Builder's Series R-410A High Efficiency Air Conditioner 13 SEER Residential System 2 5 Ton Capacity The JS6BD-K Series now offers the choice of an air conditioner that
More informationEFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER
ENVIRONMENTALLY SOUND REFRIGERANT HCA7 QuietComfort DXT+ Product Specifications HIGH EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER COMMUNICATING CONTROL SYSTEM 2 THRU 5 TONS SPLIT SYSTEM 208/230
More informationJT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 14 SEER Residential System Ton Capacity WARRANTY
TECHNICAL SPECIFICATIONS JT4BE Series R-410A High Efficiency Heat Pump 14 SEER Residential System 1.5 5 Ton Capacity The JT4BE Series now offers the choice of a heat pump that uses a more efficient and
More informationFS5BD Series High Efficiency Air Conditioner 13+ SEER Residential System Ton Capacity
TECHNICAL SPECIFICATIONS FS5BD Series High Efficiency Air Conditioner 13+ SEER Residential System 1.5-5 Ton Capacity The FS5BD Series of air conditioners offers exceptional performance. The unit, when
More informationNXA6. Product Specifications HIGH EFFICIENCY 16 SEER AIR CONDITIONER
ENVIRONMENTALLY SOUND REFRIGERANT NXA6 Performance Series Product Specifications HIGH EFFICIENCY 16 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt,
More informationJT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency Heat Pump 14 SEER Residential System 1.
TECHNICAL SPECIFICATIONS JT4BE Series High Efficiency Heat Pump 14 SEER Residential System 1.5 5 Ton Capacity The JT4BE Series of heat pumps offers exceptional performance. The unit, when combined with
More informationJS5BD-KA Series High Efficiency Air Conditioner 13+ SEER Residential System Ton Capacity
TECHNICAL SPECIFICATIONS JS5BD-KA Series High Efficiency Air Conditioner 13+ SEER Residential System 1.5-5 Ton Capacity The JS5BD Series of air conditioners offers exceptional performance. The unit, when
More informationCSA6. Product Specifications. SoftSound SXC 2600
16 SEER SINGLE STAGE AIR CONDITIONER WITH OBSERVERr COMMUNICATING CONTROL SYSTEM 1½ THRU 5 TONS SPLIT SYSTEM 208 / 2 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Copeland Scroll compressors on all models
More informationJS4BF-K(A,B) Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS
TECHNICAL SPECIFICATIONS JS4BF-K(A,B) Series R-410A Extra High Efficiency Air Conditioner 16 SEER Residential System 2-5 Ton The JS4BF-K(A,B) Series now offers the choice of an air conditioner that uses
More informationPACKAGE AIR CONDITIONERS
PACKAGE AIR CONDITIONERS FORM NO. S22-92 REV. 2 Supersedes Form No. S22-92 Rev. RLNA- SUPER HIGH EFFICIENCY SERIES NOMINAL SIZES -5 TONS [0.6-7.6 kw] *Unit shown with optional louver panels installed..0
More informationSPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS
550.13-TG1Y(98) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS HCA300, 360, 80 & 600 5 THRU 50 NOMINAL TONS HCA80 DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece
More informationGSC13 Split System Air Conditioner
Split System Air Conditioner 13 SEER / R-22 1½ to 5 Tons Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 4 AHRI Ratings... 18 Wiring Diagram... 19 Dimensions... 20 Accessories...
More informationFSH1BG Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Ultra High Efficiency Heat Pump, Up to 19 SEER Residential System 2-5 Ton Capacities
TECHNICAL SPECIFICATIONS FSH1BG Series Ultra High Efficiency Heat Pump, Up to 19 SEER Residential System 2-5 Ton Capacities The iq Drive heat pump system features modulating compressor technology and variable
More informationGSZ13. Energy-Efficient Split System Heat Pump 1½ to 5 Tons. Cooling Capacity: 17,400 to 57,000 BTU/h Heating Capacity: 17,000 to 58,000 BTU/h
Energy-Efficient Split System Heat Pump 1½ to 5 Tons Cooling Capacity: 17,400 to 57,000 BTU/h Heating Capacity: 17,000 to 58,000 BTU/h Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling
More informationSUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS
550.23-TG1Y (595) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS H4CE090 & H2CE120 & H1CE150 7-1/2, 10, & 12-1/2 NOMINAL TONS 8.9-9.5 EER SUNLINE 2000 HCE090 208/230/460 VOLT ONLY 208/230/575 VOLT ONLY DESCRIPTION
More informationTECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS Model PSA4BG Series M1200 Product Line Ultra High Efficiency Air Conditioner 20 SEER Residential System 2-5 Ton Capacities 2 The iq Drive air conditioner system features modulating
More informationTECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS Model PSH1BF Series M1200 Product Line Ultra High Efficiency Heat Pumps 16 SEER 2-5 Ton Capacity The PSH1BF Series of Maytag heat pumps offers exceptional performance as well as
More informationTECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS Model PSH4BF-KA/B Series M1200 Product Line Ultra High Efficiency Heat Pumps 16 SEER 2-5 Ton 2 The PSH4BF-KA/B Series of Maytag heat pumps offers exceptional performance as well
More informationDZ13SA. Split-System heat pump. Cooling Capacity: 17,400-55,000 BTU/h Heating Capacity: 15,200-59,000 BTU/h
Split-System heat pump Up to 14 SEER / R-410A Cooling Capacity: 17,400-55,000 BTU/h Heating Capacity: 15,200-59,000 BTU/h Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data...
More informationTSTAT0201CW (Sold Separately) Qualifying models only. Max. Fuse or Breaker
HVA9 Product Specifications HIGH EFFICIENCY UP TO 19 SEER VARIABLE SPEED AIR CONDITIONER WITH OBSERVER COMMUNICATING CONTROL SYSTEM 2 THRU 5 TONS SPLIT SYSTEM 208 230 Volt, 1 phase, 60 Hz REFRIGERATION
More informationAIR HANDLERS RBHM- SERIES AIR HANDLERS AND FAN COIL UNIT
FORM NO. H11-521 AIR HANDLERS earth friendly refrigerant RBHM- SERIES AIR HANDLERS AND FAN COIL UNIT Features Versatile 3-way convertible design for upflow, horizontal left and horizontal right. Available
More informationES5BD Series High Efficiency Air Conditioner 13+ SEER Residential System Ton Capacity
TECHNICAL SPECIFICATIONS ES5BD Series High Efficiency Air Conditioner 13+ SEER Residential System 1.5-5 Ton Capacity The ES5BD Series of air conditioners offers exceptional performance. The unit, when
More informationTECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS Model DT5BD Series M120 Product Line High Efficiency Heat Pumps 13+ SEER 1.5-5 Ton 2 12 YEAR ALL PARTS WARRANTY This product offers a 1 Year Dependability Promise to replace the
More informationR4A5. Product Specifications EFFICIENT 14 SEER/ EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT
ENVIRONMENTALLY SOUND REFRIGERANT R4A5 Product Specifications EFFICIENT 14 SEER/11.7 12.2 EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1 phase,
More informationTECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS Model PSA4BF-K(B,C) Series M1200 Product Line Extra High Efficiency Air Conditioner 16 SEER 2-5 Ton Capacity The PSA4BF-K(B,C) Series of Maytag air conditioners offers exceptional
More informationBosch BOVA Split System Heat Pump
Bosch BOVA Split System Heat Pump Condensing Units Up to 18 SEER 2-3-4-5 Ton Capacity R410A Product Specifications 2 Bosch IDS BOVA Product Specifications Data subject to change 06.2016 Bosch Thermotechnology
More informationFORM NO. HSC-543 AIR HANDLERS
FORM NO. HSC- AIR HANDLERS AH10X1 High Efficiency featuring New Industry Standard R-10A Refrigerant Features AH10X1 features the new X-1 (ECM) motor which provides enhanced SEER performance with most Sure
More informationFSH1BE Series. High Efficiency Heat Pump TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 14 SEER Residential System 1 1/2 5 Ton Capacity
TECHNICAL SPECIFICATIONS FSH1BE Series FEATURES and BENEFITS High Efficiency Heat Pump Designed Using Galvanized Steel: With a polyester urethane coat finish, it passes 9 hours of salt spray per ASTM Std.
More informationDZ14SA. Energy-Efficient Split System Heat Pump Up to 15 SEER & 9.0 HSPF. Cooling Capacity: 18,000-60,000 BTU/h Heating Capacity: 18,000-60,000 BTU/h
Cooling Capacity: 18,000-60,000 Heating Capacity: 18,000-60,000 Energy-Efficient Split System Heat Pump Up to 15 SEER & 9.0 HSPF Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling
More informationSSX14 PRODUCT SPECIFICATIONS 14 SEER / R-410A HIGH-EFFICIENCY SPLIT SYSTEM AIR CONDITIONER 1½- TO 5-TON COOLING CAPACITY 18,000 TO 56,800 BTU/H
PRODUCT SPECIFICATIONS 14 SEER / R-410A 1½- TO 5-TON COOLING CAPACITY 18,000 TO 56,800 BTU/H HIGH-EFFICIENCY SPLIT SYSTEM AIR CONDITIONER The Goodman Air Conditioner uses the environmentally friendly refrigerant
More informationSUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ DESCRIPTION FEATURES
(791) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ H1CE180 & 240 15 AND 20 NOMINAL TONS (60 HZ) 13 AND 17-1/2 NOMINAL TONS (50 HZ) SUNLINE 2000 DESCRIPTION These Sunline 2000 units are completely
More informationHS22 Bulletin # November 1992 Supersedes September 1990
ENGINEERING DATA CANADIAN EDITION FEATURES Application The HS22 series condensing units feature extra high efficiency with minimum operating sound levels. Units have seasonal energy efficiency ratings
More informationR4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT
EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 1-1/2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1- phase, 60 Hz R4A3 Product Specifications REFRIGERATION CIRCUIT S Scroll compressors
More informationSPLIT-SYSTEM AIR-COOLED CONDENSING UNITS
(1100) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS H3CE180 & 240 15 AND 20 NOMINAL TONS DESCRIPTION These outdoor condensing units are completely assembled, piped and wired at the factory to provide one-piece
More informationDT5BD Series High Efficiency Heat Pumps 13+ SEER Residential System Ton Capacity
TECHNICAL SPECIFICATIONS DT5BD Series High Efficiency Heat Pumps 13+ SEER Residential System 1.5-5 Ton The DT5BD Series of heat pumps offers exceptional performance. The heat pump, when combined with our
More informationTECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS Model MSH4BF-KA/B Series M120 Product Line R-410A Ultra High Efficiency Heat Pumps 16 SEER 2-5 Ton 2 12 YEAR ALL PARTS WARRANTY This product offers a 1 Year Dependability Promise
More informationProduct Data PH13NAZ. DUCTED HEAT PUMP Sizes 018 To To 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS
DUCTED HEAT PUMP Sizes 018 To 060 1.5 To 5 Nominal Tons Product Data A08379 INDUSTRY LEADING FEATURES / BENEFITS Energy Efficiency S Sound S Levels as low as 71 dba Design Features S New aesthetics S Small
More informationFT4BD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 13 SEER Residential System 1 1/2 5 Ton Capacity
TECHNICAL SPECIFICATIONS FT4BD Series R-410A High Efficiency Heat Pump 13 SEER Residential System 1 1/2 5 Ton Capacity The FT4BD Series now offers the choice of a heat pump that uses a more efficient and
More informationP7RE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner
TECHNICAL SPECIFICATIONS P7RE Series Single Packaged Air Conditioner P7RE 14 SEER 2 thru 5 Ton Units Cooling: 23,800 to 56,000 Btuh The P7 Series single packaged air conditioners are high efficiency self
More informationN4A4 C. Product Specifications
COASTAL 14 SEER AIR CONDITIONER 14 SEER/11.5 12.5 EER R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Scroll compressors on all models Filter drier
More informationET4BD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. ET4BD Series R-410A High Efficiency Heat Pump WARRANTY
TECHNICAL SPECIFICATIONS ET4BD Series ET4BD Series R-410A High Efficiency Heat Pump 13 SEER Residential System 1 1/2 5 Ton Capacity WARRANTY FEATURES and BENEFITS R-410A Refrigerant: Earth friendly non-ozone
More informationTECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS Model CSA4BE Series M120 Product Line High Efficiency Air Conditioner 14 SEER 1.5-5 Ton Capacity 2 The CSA4BE Series of air conditioners offers exceptional performance. The unit,
More informationLISTED TECHNICAL GUIDE STEALTH SPLIT-SYSTEM HEAT PUMP 15 SEER MODELS: E4TS030 THRU 060 (2.5 THRU 5 NOMINAL TONS) DESCRIPTION FEATURES
P G 036-21342-002 Rev. C (0902) TECHNICAL GUIDE STEALTH SPLIT-SYSTEM HEAT PUMP 15 SEER MODELS: E4TS030 THRU 060 (2.5 THRU 5 NOMINAL TONS) U R MA N U F A CT R E C E CE R T I F R T I UN I TA RY A R I F I
More informationFSH1BF Series. Extra High Efficiency Heat Pump TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 16 SEER Residential System 2-5 Ton Capacity
TECHNICAL SPECIFICATIONS FSH1BF Series FEATURES and BENEFITS Extra High Efficiency Heat Pump CoreSenseTM Compressor Protection: Control module actively monitors compressor conditions and will shut the
More informationWCA4**4. Product Specifications
WCA4**4 AIR CONDITIONER EFFICIENT 14 SEER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208/2 Volt, 1 phase, 60 Hz Use of the AHRI Certified TM Mark indicates a manufacturer s participation
More informationCOMMERCIAL H4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER
ENVIRONMENTALLY SOUND REFRIGERANT COMMERCIAL H4A3 DX 1300 Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt,
More informationS6BQ Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Split System 2-Stage Air Conditioner. 7 1/2 and 10 Ton rated at 11.2 EER and 12.
TECHNICAL SPECIFICATIONS S6BQ Series Split System 2-Stage Air Conditioner 7 1/2 and 10 Ton rated at 11.2 EER and 12.9 IEER The S6BQ Series of air conditioners offers exceptional performance. The unit,
More informationRuud High Efficiency Air Handler
Air Handlers Ruud High Efficiency Air Handler RHLL- Series X-1 (ECM) Efficiencies up to 16 SEER RHLL feature an X-1 (ECM) motor which provides enhanced SEER performance with most Ruud outdoor units. Versatile
More informationTECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS Model MSH4BE Series M120 Product Line R-410A High Efficiency Heat Pump 14 SEER 1.5-5 Ton Capacity 12 YEAR ALL PARTS WARRANTY This product offers a 1 Year Dependability Promise
More informationSUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ)
550.39-TG1YI (994) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS H5CE090 & H3CE120 7.5 AND 10 NOMINAL TONS (World 50HZ) HCE090 SUNLINE 2000 DESCRIPTION These Sunline 2000 units are completely assembled, piped
More information