High-pressure In-line Pump. Movitec B. 50 Hz. Type Series Booklet

Size: px
Start display at page:

Download "High-pressure In-line Pump. Movitec B. 50 Hz. Type Series Booklet"

Transcription

1 High-pressure In-line Pump Movitec B 5 Hz Type Series Booklet

2 Legal information/copyright Type Series Booklet Movitec B KSB ktiengesellschaft ll rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited or processed for any other purpose, nor otherwise transmitted, published or made available to a third party without KSB's express written consent. Subject to technical modification without prior notice. KSB ktiengesellschaft Frankenthal

3 Contents Contents High-pressure pumps Movitec B... 5 Main applications... 5 Fluids handled... 5 Operating data...5 Designation... 5 Design details... 5 Materials...6 Coating and preservation...7 Product benefits... 7 Product Information as per Regulation No. 547/212 (for Water Pumps with a Maximum Shaft Power of 15 kw) Implementing "Ecodesign" Directive 29/125/EC... 7 cceptance tests / Warranties... 8 Selection information... 8 Notes on using the characteristic curve... 8 Fluid handled...8 Minimum/maximum flow rate... 8 Detailed designation... 9 Pressure and temperature limits Fluids handled Technical data Movitec VME, 3~23/4 V Movitec VE, 3~23/4 V...15 Movitec V, "fixed" mechanical seal, 1-23 V...15 Movitec V, "fixed" mechanical seal, 3~23/4 V, 3~4/69 V Movitec V, "easy access" mechanical seal, 3~23/4 V, 3~4/69 V...18 Movitec VF, "easy access" mechanical seal, 3~23/4 V, 3~4/69 V... 2 Movitec VCF, "easy access" mechanical seal, 3~23/4 V, 3~4/69 V Movitec VS, "easy access" mechanical seal, 3~23/4 V, 3~4/69 V Movitec VSF, "easy access" mechanical seal, 3~23/4 V, 3~4/69 V Movitec VCF 9, "easy access" mechanical seal, 3~4/69 V Movitec VF 9, "easy access" mechanical seal, 3~4/69 V Movitec VSF 9, "easy access" mechanical seal, 3~4/69 V...28 Types of connection...29 Terminal box positions...29 Selection charts... 3 Movitec B; n = 29 rpm... 3 Movitec B; n = 145 rpm Characteristic curves...31 n = 29 rpm Movitec B; 2; n = 29 rpm Movitec B; 4; n = 29 rpm Movitec B; 6; n = 29 rpm Movitec B; 1; n = 29 rpm

4 Contents Movitec B; 15; n = 29 rpm Movitec B; 25, n = 29 rpm Movitec B; 9; n = 29 rpm n = 145 rpm Movitec B; 1; n = 145 rpm Movitec B; 15; n = 145 rpm... 4 Movitec B; 25, n = 145 rpm Movitec B; 9; n = 145 rpm Dimensions Movitec B, V 2, n = 29 rpm Movitec B, V 4, n = 29 rpm Movitec B, V 6, n = 29 rpm Movitec B, V 1, n = 145 rpm...46 Movitec B, V 1, n = 29 rpm...47 Movitec B, V 15, n = 145 rpm...48 Movitec B, V 15, n = 29 rpm...49 Movitec B, V 25, n = 145 rpm...5 Movitec B, V 25, n = 29 rpm...51 Movitec B, VCF 9, V(S)F Movitec B, VCF 9, V(S)F 9, without motor Movitec B, VME 2, 4, 6, VE Notes on installation Scope of supply ccessories General assembly drawing with list of components...57 Movitec V 2 B, 4 B, 6 B Movitec V(S) 1 B, 15 B, 25 B Movitec V 9 B...6 4

5 High-pressure pumps Movitec B Operating data Operating properties Characteristic Value Flow rate Q Up to m 3 /h (31. l/s) Head H Up to 249 m Operating temperature t -2 C to +14 C 1) Operating pressure P Operating pressure up to 4 bar max. 2) Main applications Spray irrigation systems Irrigation systems Washing plants Fire-fighting systems Pressure boosting Industrial plants Water supply systems Heating, ventilation and air-conditioning systems Marine applications Fluids handled High-temperature hot water Clear water Condensate Cooling water Fire-fighting water Oil Cleaning agents nd others ( Page 12) Designation Example: Movitec VCF 9/2-1 B Key to the designation Code Movitec VC F Description Type series Design V Stainless steel/cast steel (pump casing) Stainless steel (hydraulic system of the pump) VS Stainless steel/cast steel (pump casing) Stainless steel (hydraulic system of the pump) VC Grey cast iron (pump casing) Stainless steel (hydraulic system of the pump) VM Version with close-coupled motor Type of connection - Oval flange E External thread F T Tri-clamp coupling V Victaulic coupling 9 Size, flow rate [m³/h] at Q opt 2, 4, 6, 1, 15, 25, 9 2 Number of stages -1 Number of reduced stages B Generation Design details Design High-pressure in-line pump Maximum pressure class PN 4 Centrifugal pump Single-stage or multi-stage Installation types Standard: Vertical installation Optional: Horizontal installation Drive Surface-cooled KSB squirrel-cage motor 3~23/4 V up to 2.2 kw 3~4/69 V from 3 kw 1) Standard: -2 C to +12 C. For temperatures > 12 C suitable mechanical seals are required. 2) The sum of inlet pressure and head at zero flow point must not exceed the value indicated. Movitec B 5

6 Thermal class F to IEC34-1 Efficiency class IE2 (from.75 kw) IP 55 enclosure Frequency 5 Hz Thermal class F Shaft seal The shaft seal is an uncooled, maintenance-free mechanical seal to EN Fixed design Standard-design mechanical seal, non-balanced bellowstype seal, max. 25 bar Easy ccess design Easy-to-replace, non-balanced bellows-type seal, max. 25 bar Drive lantern need not be removed to replace the seal. Motor rating 5.5 kw and above: Motor need not be removed. Cartridge design Cartridge-type seal, available in non-balanced bellowstype design (PN 25) or in special balanced PN 4 design. Drive lantern need not be removed to replace the seal. Motor rating 5.5 kw and above: Motor need not be removed. Bearings Tungsten carbide plain bearings at the hydraulic rotor Materials Overview of materials available for pump components Part No. Description VC V VS 11 Pump casing JL Stage casing ) / ) ) / ) 16 Discharge cover ) ) / ) ) / ) 1-6 Pump shroud Shaft Impeller ) / ) ) / ) 341 Drive lantern JL O-ring EPDM EPDM-WRc / CS / CS VITON / HNBR 5) 525 Spacer sleeve Bearing sleeve Tungsten carbide / aluminium oxide 89 Baseplate - JS 13 / JL 14 / ) 95 Tie bolt Nut Circlip Key to materials of pump components Material Material designation / material number Standard To STM Grey cast iron JL14 / GJL-25 EN :4B Chrome nickel steel / X5CrNi18-1 EN : QT8 / X17CrNi16-2-QT8 EN : / X5CrNiMo EN : / GX5CrNi19-1 EN :CF8 Chrome nickel molybdenum steel / X2CrNiMo EN :316L / X6CrNiMoTi EN :316 3) Movitec 2B, 4B, 6B, 1B, 15B 4) Movitec 9B 5) On model with round flange 6 Movitec B

7 Material Material designation / material number Standard To STM / X3CrNiMoN EN 188 Carbon chromium nickel molybdenum steel / GX5CrNiMo EN CF8M Material key for mechanical seal Seal code Designation to EN Contact face materials / secondary seals 13 Q1BEGG-WRc Silicon carbide / hard carbon / EPDM WRc 14 Q1BVGG Silicon carbide / hard carbon / Viton 15 U3U3X4GG Tungsten carbide / tungsten carbide / HNBR 16 U3U3VGG Tungsten carbide / tungsten carbide / Viton 18 U3BEGG Tungsten carbide / hard carbon / EPDM 2 Q1EGG Silicon carbide / hard carbon / EPDM Q1VGG Silicon carbide / hard carbon / Viton 22 Q1X4GG Silicon carbide / hard carbon / HNBR 23 Q1BEGG Silicon carbide / hard carbon / EPDM Key to mechanical seal materials Designation Description Contact face materials / secondary seals to EN Q1 Primary ring Silicon carbide (sintered without pressure) U3 Primary ring Tungsten carbide (CrNiMo binder) B Mating ring Hard carbon, resin-impregnated U3 Mating ring Tungsten carbide (CrNiMo binder) Mating ring Carbon graphite, antimony-impregnated E Elastomer EPDM (ethylene propylene rubber) V Elastomer Fluoroelastomer (Viton) X4 Elastomer HNBR G Spring CrNiMo steel G Other metal parts CrNiMo steel Coating and preservation Coating of pump components Component Coating Stainless steel components No additional coating Movitec VC: Pump casing made of grey cast Cataphoretic coating iron Movitec V/VS: Slide flanges made of grey Cataphoretic coating cast iron Drive lantern made of grey Powder coating cast iron Product benefits Reliable: product-lubricated plain bearings made of tungsten carbide, cast pump foot, torsion-resistant pump shroud and confined O-rings Long service life due to corrosion-resistant hydraulic components made of stainless steel Easy to service: Can be fitted with any standardised mechanical seal (to EN 12756) Various materials and line connection options, extended temperature and pressure range Product Information as per Regulation No. 547/212 (for Water Pumps with a Maximum Shaft Power of 15 kw) Implementing "Ecodesign" Directive 29/125/EC Minimum efficiency index: see data sheet The benchmark for most efficient water pumps is MEI.7. Year of construction: see data sheet Manufacturer s name or trade mark, commercial registration number and place of manufacture: see data sheet or order documentation Product s type and size identificator: see data sheet Hydraulic pump efficiency (%) with trimmed impeller: see data sheet Pump performance curves, including efficiency characteristics: see documented characteristic curve The efficiency of a pump with a trimmed impeller is usually lower than that of a pump with the full impeller diameter. Trimming of the impeller will adapt the pump to a fixed duty point, leading to reduced energy consumption. The minimum efficiency index (MEI) is based on the full impeller diameter. The operation of this water pump with variable duty points may be more efficient and economic when controlled, for example, by the use of a variable speed drive that matches the pump duty to the system. Information relevant for disassembly, recycling or disposal at end of life: see installation/operating manual Movitec B 7

8 Information on benchmark efficiency or benchmark efficiency graph for MEI =.7 (.4) for the pump based on the model shown in the Figure are available at: cceptance tests / Warranties Internal pressure test to EN 89 Leak test with water Materials testing Certificate of compliance with the order (corresponds to EN 124) In the certificate of compliance with the order the manufacturer confirms by way of an informal report without specifying test results that the delivery complies with the stipulations of the purchase order. Test report 2.2 on request Product inspection Inspection certificate 3.1 to EN 124 on request Hydraulic test The duty point of each pump is guaranteed according to ISO 996/2. This test is always carried out using the original motor. The NPSH and the suction lift are not measured (3.2 certificate available). Warranty Warranties are given within the scope of the valid delivery conditions. Minimum/maximum flow rate Minimum/maximum flow rate (Q) at a fluid temperature 2 C Size 2-pole Q [m³/h] 4-pole Min. Max. Min. Max. 2,2 3, ,4 6, ,6 9, ,1 6) 13,2,5 6,6 15 1,6 6) 22,5,8 11,3 25 2,8 35, 1,4 17,5 45 4,6 57, ,1 75, ,5 11, 4,3 53,9 LHS6,8 8,6 1,4 - Q [%] Minimum flow rate required as a function of fluid temperature at a fluid temperature > 2 C t [ C] Selection information Notes on using the characteristic curve NPSH: The NPSH values given in the individual characteristic curves are minimum values which correspond to the cavitation limit. safety allowance of at least.5 m must be added when selecting the pump to compensate for measuring inaccuracies. The NPSH curves reflect average values. safety allowance of.5 m must be added to the NPSH value of the characteristic curve when selecting a system. Fluid handled The actual operating conditions must always be checked (concentration, temperature, solids content). The penetration of air into the system must be avoided by all means. If the fluid handled contains solids such as steel chips or steel dust, check the permissible particle concentration with the technical or sales department. 6) For pumps with VdS certification, the minimum flow rate Q min is 5 % of the permissible flow rate. 8 Movitec B

9 Detailed designation Example: M o v i t e c V C F 9 / 2 1 B E X Name (1-7) Code Movitec Version (8-9) Description Movitec Code Description V VC 1.431/GG VM 1.431/monobloc motor VS 1.441/1.444 Line connection (1) Code Description - Oval flange E External thread F T Tri-clamp coupling V Victaulic coupling Size (11-13) Code Description 2 Size 2 4 Size 4 6 Size 6 1 Size 1 15 Size Size Size 9 Number of stages (15-16) Code Description 1 1 stage 2 2 stages 3 3 stages 4 4 stages 5 5 stages 6 6 stages 7 7 stages 8 8 stages 9 9 stages 1 1 stages stages stages stages stages stages stages stages stages stages 2 2 stages stages stages stages stages stages 3 3 stages Number of reduced stages (17) Code Description - No reduced stage 1 One reduced stage 2 Two reduced stages Generation (18) Code B Connection standard (19) Description Previous generation New generation Code Description Victaulic / no standard 1 EN SME B JIS B EN ISO SME B16.5 oval flange 6 DIN EN ISO ISO SME B16.5 round flange Material variant (2) Code Description 34 - JL 14 - JL 14 B 34 - JL C 34 - JL 14 - JS 13 D 34 - JS 13 - JL 14 E 34 - JS F JL 14 G JS 13 H K JS 13 L JL 14 M N JS 13 - JL 14 O JS P JL 14 Q R JL 14 S JS 13 T U JL 14 -JL 14 -JL 14 Seal code (21-22) Code Description 13 Q1BEGG-WRC-EPDM-WRC 14 Q1BVGG-Viton 15 U3U3X4GG-HNBR 16 U3U3VGG-Viton 18 U3BEGG-EPDM 2 Q1EGG-EPDM 21 Q1VGG-Viton 22 Q1X4GG-HNBR 23 Q1BEGG Movitec B 9

10 Design of mechanical seal (23) Code F E C Drive (24) Description "Fixed" design "Easy access" design Cartridge design Code Description P With PumpDrive TEX IEC S Standard IEC N NEM standard Without motor Motor rating and number of poles (25-28) Code Description 24,25 kw, 4-pole 32,37 kw, 2-pole 34,37 kw, 4-pole 52,55 kw, 2-pole 54,55 kw, 4-pole 56 NEM 58c 71 IEC 71 72,75 kw, 2-pole 74,75 kw, 4-pole 8 IEC 8 9 IEC 9S/L 1 IEC 1L 112 1,1 kw, 2-pole 112 IEC 112M 114 1,1 kw, 4-pole 132 1,3 kw, 2-pole 132 IEC 132S/M 143 NEM 143TC 145 NEM 145TC 152 1,5 kw, 2-pole 154 1,5 kw, 4-pole 16 IEC 16M/L 18 IEC 18M/L 182 NEM 182TC 184 NEM 184TC 192 1,85 kw, 2-pole 2 IEC 2L 215 NEM 215TC 222 2,2 kw, 2-pole 224 2,2 kw, 4-pole 225 IEC 225M 252 2,5 kw, 2-pole 256 NEM 256TC 284 NEM 284TSC 286 NEM 286TSC 32 3, kw, 2-pole 34 3, kw, 4-pole 324 NEM 324TSC 326 NEM 326TSC 352 3,3 kw, 2-pole 364 NEM 364TSC 42 4, kw, 2-pole 44 4, kw, 4-pole 462 4,6 kw, 2-pole 552 5,5 kw, 2-pole 554 5,5 kw, 4-pole 752 7,5 kw, 2-pole 754 7,5 kw, 4-pole 12 1, kw, 2-pole , kw, 2-pole Code Description ,5 kw, 2-pole , kw, 2-pole ,5 kw, 2-pole 22 2, kw, 2-pole , kw, 2-pole , kw, 2-pole , kw, 2-pole 32 3, kw, 2-pole , kw, 2-pole , kw, 2-pole , kw, 2-pole Mains frequency (29) Code Description 5 5 Hz 6 6 Hz Motor voltage (3) Code Description 23/4 V - IE1 B 4/69 V - IE1 C 23/4 V - IE2 D 4/69 V - IE2 E EXM IEC - DP F EXM IEC - TBH G EXM NEM J 4/69 V - IE 2 K EXM IEC - Movitec L 4/69 V - IE 2/PDX M 23 V - single-phase PumpMeter (31) Code W Standard (32) Code X Description With PumpMeter Without PumpMeter Description One or several non-standard components 1 Movitec B

11 Pressure and temperature limits Pressure and temperature limits Seal code Material variant Temperature of the fluid handled [ C] 7) Maximum operating Standard Optional Minimum Maximum pressure [bar] 13 14, 15, 16, 18 V / 25 8) 14 13, 15, 16, 18 VS 23 13, 14, 15, 16, 18 VC 21 - V / 25 9) 22 - VS 2 - VC 7) Subject to special application limits (see list of fluids handled) 8) Depending on line connection version 9) 12 C - 14 C: PN 16 Movitec B 11

12 Fluids handled The data refer to the chemical resistance of the materials. The relevant regulations / standards governing individual pump applications have to be complied with. The actual operating conditions must always be checked (concentration, temperature, solids content). The penetration of air into the system must be avoided by all means. If the operating conditions differ from the data given (e.g. mixed products) or if the fluids are not included in the table below, please contact KSB. Temperature ranges: Reference temperature: 2 C. For temperatures < C: contact KSB. For temperatures >5 C: check and observe the vapour pressure of the fluid handled. Max. temperature = 12 C, unless indicated otherwise. Max. concentration = 1 % unless indicated otherwise. Mechanical seal silicon carbide / carbon (Q1B): not suitable for fluids containing solid substances. This rule also covers particles developing as a result of salt crystallisation at low fluid temperatures. Mechanical seal tungsten carbide / tungsten carbide (U3U3): solids content max. 2 ppm (depending on particle size), with the exception of corrosive media. Fluids with a higher solids content are not permitted (ppm = 1 mg/kg). Caution: High temperatures will increase corrosion (reference temperature = 2 C). Under unfavourable conditions (high temperatures, deposits, long idle periods), chloride contents of more than 3 mg/l may result in localised corrosion. Fluid selection table Fluid handled Max. content [%] Max. Mechanical seal variant temperatu re [ C] lum, acid-free 1) V/VS lkaline solution, bottle rinsing, max. 2% VC/V/V - - sodium hydroxide S lcohol - Butanol - 6 VC VC/V/VS Ethanol - 6 VC VC/V/VS Propanol - 8 VC VC/V/VS Spirits (4 % ethanol) V/VS Wine (white, red) V/VS V/VS mmonium bicarbonate 1 4 VC VC/V/VS luminium sulphate, acid-free 11) V/VS - mmonium sulphate V/VS Calcium acetate, acid-free 1 6 VC VC/V/VS Calcium nitrate, acid-free V/VS - Ferric sulphate (II) V/VS - Water-oil emulsion (95 %, 5 %), free of solids VC/V/V S Ethylene glycol base anti-freeze, inhibited, 2 11 VC 12) VC/V/ VC/V/V - VC/V/VS 13) - closed system VS 12) S VC 12) VC/V/ VC/V/V - VC/V/VS 13) - VS 12) S 3 11 VC 12) VC/V/ VC/V/V - VC/V/VS 13) - VS 12) S VC 12) VC/V/ VC/V/V - VC/V/VS 13) - VS 12) S 4 11 VC 12) VC/V/ VC/V/V - VC/V/VS 13) - VS 12) S VC 12) VC/V/ VS 12) VC/V/V S - VC/V/VS 13) - 1) Movitec V up to 5 C, Movitec VS up to 8 C, not for Movitec VC 11) Movitec V up to 5 C, Movitec VS up to 6 C, not for Movitec VC 12) 1 C max. 13) 11 C max. 12 Movitec B

13 Fluid handled Ethylene glycol base anti-freeze, inhibited, open system Max. content [%] Max. Mechanical seal variant temperatu re [ C] 5 11 VC 12) VC/V/ VS 12) VC/V/V S - VC/V/VS 13) V/VS 12) V/VS - V/VS 13) V/VS 12) V/VS - V/VS 13) V/VS 12) V/VS - V/VS 13) V/VS 12) V/VS - V/VS 13) V/VS 12) V/VS - V/VS 13) V/VS 12) V/VS - V/VS 13) V/VS 12) V/VS - V/VS 13) S Glycerin 4 8 VC VC/V/VS VC/V/V Glycols (pure) Diethylene glycol - 1 VC VC/V/VS VC/V/V S Ethylene glycol - 1 VC VC/V/VS VC/V/V S Potassium hydroxide VC/V/V - - S Potassium nitrate, acid-free VC/V/V - - S Potassium sulphate, acid-free VC/V/V S Copper sulphate V/VS - - Magnesium sulphate V/VS Milk V/VS V/VS Sodium carbonate 6 6 VC VC/V/VS Sodium hydroxide VC/V/V S - - Sodium nitrate, acid-free 14) 1 6 VC VC/V/VS Sodium sulphate, acid-free V/VS Oil - Peanut oil VC/V/V S - Linseed oil, max. 3 % H 2 SO 15) V/VS Linseed oil VC/V/V S - Corn oil VC/V/V S - Rapeseed oil VC/V/V S - Soybean oil VC/V/V S Kerosene V/VS Juice (fruit and sugar juice) V/VS cid - cetic acid V/VS cetic acid V/VS Tannic acid V/VS Maleic acid V/VS Lactic acid V/VS Lactic acid V/VS Phosphoric acid V/VS Sulphuric acid VS - - Tartaric acid VS Citric acid V/VS Citric acid V/VS Fuel - Diesel oil V/VS ) Movitec V up to 6 C, Movitec VS up to 6 C, Movitec VC up to 3 C 15) Movitec V up to 2 C, Movitec VS up to 6 C, not for Movitec VC Movitec B 13

14 Fluid handled Max. content [%] Max. Mechanical seal variant temperatu re [ C] VC/V/VS 16) VC/V/VS 16) VC/V/VS 16) VC/V/VS 16) VC/V/VS 16) - Heating oil V/VS Kerosene V/VS Trisodium phosphate VC/V/V - - S Water - Deionised water (fully desalinated) V/VS 12) V/VS 16) - Dealkalised water V/VS 16) Decarbonised water V/VS 16) Permeate (osmosis) V/VS 12) V/VS 16) - Partly desalinated water V/VS 16) Fire-fighting water VC/V/V S - VC/V/VS 16) - Heating water up to max. 1 C, to VDI VC 12) VC/V/ VS 12) - Hot water treated in acc. with VdTÜV VC 12) VC/V/ VS 12) - Boiler feed water in acc. with VdTÜV VC 12) VC/V/ VS 12) - Condensate treated in acc. with VdTÜV VC 12) VC/V/ VS 12) - Vapour condensate (brewery) - 14 VC 12) VC/V/ VS 12) - Cooling water VC/V/VS - - Tap water VC/V/VS Brewing water VC/V/VS Ice water (brewery) VC/V/VS Tap water / drinking water VC/V/VS Hot water (brewery) VC/V/VS Clean water - 6 VC VC/V/VS VC/V/V S VC/V/V S VC/V/VS VC/V/VS - Brackish water VS - - Seawater VS - - Raw water VC/V/V - - S - Waste water, slightly contaminated water VC/V/V - - S - River water VC/V/V - - S - Lake water VC/V/V - - S - Dam water VC/V/V - - S - Surface water VC/V/V - - S - Fresh water VC/V/V S Barrier water VC/V/VS - - Flushing water VC/V/VS - - Rainwater, with strainer VC/V/VS - 16) 12 C max. 14 Movitec B

15 Technical data Movitec VME, 3~23/4 V "Fixed" mechanical seal, code 13, close-coupled motor IE2, external thread with integrated non-return valve (discharge side), fixed speed - 3~23/4 V Size Number of stages Motor rating Max. current [kw] [] Mat. No. [kg] 2-pole Movitec VME 2 2,37 1,64 /, Movitec VME 2 3,37 1,64 /, Movitec VME 2 4,37 1,64 /, Movitec VME 2 5,37 1,64 /, Movitec VME 2 6,55 2,31 / 1, Movitec VME 4 2,37 1,64 /, Movitec VME 4 3,55 2,31 / 1, Movitec VME 4 4,55 2,31 / 1, Movitec VME 4 5,75 2,99 / 1, Movitec VME 4 6 1,1 4,22 / 2, Movitec VME 6 2,37 1,64 /, Movitec VME 6 3,75 2,99 / 1, Movitec VME 6 4 1,1 4,22 / 2, Movitec VME 6 5 1,1 4,22 / 2, Movitec VE, 3~23/4 V "Fixed" mechanical seal, code 13, motor IE2, external thread with integrated non-return valve (discharge side), fixed speed - 3~23/4 V Size Number of stages Motor rating Max. current [kw] [] Mat. No. [kg] 2-pole Movitec VE 1 1,75 2,99 / 1, Movitec VE 1 2,75 2,99 / 1, Movitec VE 1 3 1,1 4,22 / 2, Movitec VE 1 4 1,5 5,5 / 2, Movitec VE 1 5 2,2 7,25 / 4, Movitec VE 1 6 2,2 7,25 / 4, Movitec VE 1 7 3, 5,55 / 3, Movitec VE 1 8 3, 5,55 / 3, Movitec V, "fixed" mechanical seal, 1-23 V Movitec V, "fixed" mechanical seal, with KSB standard motor IE2 17), fixed speed - 1~23 V Size Number of stages Shaft seal code Motor rating Max. current Oval flange Movitec V Movitec VF [kw] [] Mat. No. [kg] Mat. No. [kg] 2-pole Movitec V ,37 2, Movitec V ,37 2, Movitec V ,37 2, Movitec V ,37 2, Movitec V ,55 3, Movitec V ,55 3, Movitec V ,55 3, Movitec V ,75 5, Movitec V ,75 5, ) IE2 for motor ratings.75 kw Movitec B 15

16 Size Number of stages Shaft seal code Motor rating Max. current Oval flange Movitec V Movitec VF [kw] [] Mat. No. [kg] Mat. No. [kg] Movitec V ,1 6, Movitec V ,1 6, Movitec V ,1 6, Movitec V ,5 8, Movitec V ,5 8, Movitec V ,5 8, Movitec V ,2 13, Movitec V ,2 13, Movitec V ,2 13, Movitec V ,2 13, Movitec V ,2 13, Movitec V ,37 2, Movitec V ,55 3, Movitec V ,55 3, Movitec V ,75 5, Movitec V ,1 6, Movitec V ,1 6, Movitec V ,5 8, Movitec V ,5 8, Movitec V ,5 8, Movitec V ,2 13, Movitec V ,2 13, Movitec V ,2 13, Movitec V ,37 2, Movitec V ,75 5, Movitec V ,1 6, Movitec V ,1 6, Movitec V ,5 8, Movitec V ,5 8, Movitec V ,2 13, Movitec V ,2 13, Movitec V ,2 13, Movitec V ,75 5, Movitec V ,75 5, Movitec V ,1 6, Movitec V ,5 8, Movitec V ,2 13, Movitec V ,2 13, Movitec V ,1 6, Movitec V ,2 13, Movitec V, "fixed" mechanical seal, 3~23/4 V, 3~4/69 V Movitec V, "fixed" mechanical seal, with KSB standard motor IE2 18), fixed speed - 3~23/4 V up to 2.2 kw, for 3 kw and higher 3~4/69 V Size Number of stages Shaft seal code Motor rating Max. current Oval flange Movitec V Movitec VF [kw] [] Mat. No. [kg] Mat. No. [kg] 2-pole Movitec V ,37 1,64 /, Movitec V ,37 1,64 /, Movitec V ,37 1,64 /, Movitec V ,37 1,64 /, Movitec V ,55 2,31 / 1, ) IE2 for motor ratings.75 kw 16 Movitec B

17 Size Number of stages Shaft seal code Motor rating Max. current Oval flange Movitec V Movitec VF [kw] [] Mat. No. [kg] Mat. No. [kg] Movitec V ,55 2,31 / 1, Movitec V ,55 2,31 / 1, Movitec V ,75 2,99 / 1, Movitec V ,75 2,99 / 1, Movitec V ,1 4,22 / 2, Movitec V ,1 4,22 / 2, Movitec V ,1 4,22 / 2, Movitec V ,5 5,5 / 2, Movitec V ,5 5,5 / 2, Movitec V ,5 5,5 / 2, Movitec V ,2 7,25 / 4, Movitec V ,2 7,25 / 4, Movitec V ,2 7,25 / 4, Movitec V ,2 7,25 / 4, Movitec V ,2 7,25 / 4, Movitec V ,37 1,64 /, Movitec V ,55 2,31 / 1, Movitec V ,55 2,31 / 1, Movitec V ,75 2,99 / 1, Movitec V ,1 4,22 / 2, Movitec V ,1 4,22 / 2, Movitec V ,5 5,5 / 2, Movitec V ,5 5,5 / 2, Movitec V ,5 5,5 / 2, Movitec V ,2 7,25 / 4, Movitec V ,2 7,25 / 4, Movitec V ,2 7,25 / 4, Movitec V , 5,55 / 3, Movitec V , 5,55 / 3, Movitec V , 5,55 / 3, Movitec V , 7,29 / 4, Movitec V , 7,29 / 4, Movitec V , 7,29 / 4, Movitec V ,37 1,64 /, Movitec V ,75 2,99 / 1, Movitec V ,1 4,22 / 2, Movitec V ,1 4,22 / 2, Movitec V ,5 5,5 / 2, Movitec V ,5 5,5 / 2, Movitec V ,2 7,25 / 4, Movitec V ,2 7,25 / 4, Movitec V ,2 7,25 / 4, Movitec V , 5,55 / 3, Movitec V , 5,55 / 3, Movitec V , 5,55 / 3, Movitec V , 7,29 / 4, Movitec V , 7,29 / 4, Movitec V ,5 1,7 / 5, Movitec V ,5 1,7 / 5, Movitec V ,5 1,7 / 5, Movitec V ,5 1,7 / 5, Movitec V ,75 2,99 / 1, Movitec V ,75 2,99 / 1, Movitec V ,1 4,22 / 2, Movitec V ,5 5,5 / 2, Movitec V ,2 7,25 / 4, Movitec V ,2 7,25 / 4, Movitec V , 5,55 / 3, Movitec V , 5,55 / 3, Movitec B 17

18 Size Number of stages Shaft seal code Motor rating Max. current Oval flange Movitec V Movitec VF [kw] [] Mat. No. [kg] Mat. No. [kg] Movitec V , 7,25 / 4, Movitec V , 7,25 / 4, Movitec V , 7,25 / 4, Movitec V ,5 1,7 / 5, Movitec V ,5 1,7 / 5, Movitec V ,5 13,6 / 7, Movitec V ,5 13,6 / 7, Movitec V ,5 13,6 / 7, Movitec V ,1 4,22 / 2, Movitec V ,2 7,25 / 4, Movitec V , 5,55 / 3, Movitec V , 7,25 / 4, Movitec V ,5 1,7 / 5, Movitec V ,5 1,7 / 5, Movitec V ,5 13,6 / 7, Movitec V ,5 13,6 / 7, Movitec V , 19,47 / 11, Movitec V , 19,47 / 11, Movitec V , 19,47 / 11, Movitec V , 26,35 / 15, Movitec V , 26,35 / 15, Movitec V , 26,35 / 15, Movitec V, "easy access" mechanical seal, 3~23/4 V, 3~4/69 V Movitec V, "easy access" mechanical seal, with KSB standard motor IE2 19), fixed/variable speed - 3~23/4 V up to 2.2 kw, for 3 kw and higher 3~4/69 V Size Number of stages Shaft seal code Motor rating Max. current Oval flange Movitec V Fixed speed Oval flange Movitec V Variable speed [kw] [] Mat. No. [kg] Mat. No. [kg] 2-pole Movitec V ,37 1,64 /, Movitec V ,37 1,64 /, Movitec V ,37 1,64 /, Movitec V ,37 1,64 /, Movitec V ,55 2,31 / 1, Movitec V ,55 2,31 / 1, Movitec V ,55 2,31 / 1, Movitec V ,75 2,99 / 1, Movitec V ,75 2,99 / 1, Movitec V ,1 4,22 / 2, Movitec V ,1 4,22 / 2, Movitec V ,1 4,22 / 2, Movitec V ,5 5,5 / 2, Movitec V ,5 5,5 / 2, Movitec V ,37 1,64 /, Movitec V ,55 2,31 / 1, Movitec V ,55 2,31 / 1, Movitec V ,75 2,99 / 1, Movitec V ,1 4,22 / 2, Movitec V ,1 4,22 / 2, Movitec V ,5 5,5 / 2, Movitec V ,5 5,5 / 2, Movitec V ,5 5,5 / 2, Movitec V ,2 7,25 / 4, ) IE2 for motor ratings.75 kw 18 Movitec B

19 Size Number of stages Shaft seal code Motor rating Max. current Oval flange Movitec V Fixed speed Oval flange Movitec V Variable speed [kw] [] Mat. No. [kg] Mat. No. [kg] Movitec V ,2 7,25 / 4, Movitec V ,2 7,25 / 4, Movitec V , 5,55 / 3, Movitec V ,37 1,64 /, Movitec V ,75 2,99 / 1, Movitec V ,1 4,22 / 2, Movitec V ,1 4,22 / 2, Movitec V ,5 5,5 / 2, Movitec V ,5 5,5 / 2, Movitec V ,2 7,25 / 4, Movitec V ,2 7,25 / 4, Movitec V ,2 7,25 / 4, Movitec V , 5,55 / 3, Movitec V , 5,55 / 3, Movitec V , 5,55 / 3, Movitec V , 7,29 / 4, Movitec V ,75 2,99 / 1, Movitec V ,75 2,99 / 1, Movitec V ,1 4,22 / 2, Movitec V ,5 5,5 / 2, Movitec V ,2 7,25 / 4, Movitec V ,2 7,25 / 4, Movitec V , 5,55 / 3, Movitec V , 5,55 / 3, Movitec V , 7,25 / 4, Movitec V , 7,25 / 4, Movitec V , 7,25 / 4, Movitec V ,5 1,5 / 5, Movitec V ,1 4,22 / 2, Movitec V ,2 7,25 / 4, Movitec V , 5,55 / 3, Movitec V , 7,25 / 4, Movitec V ,5 1,5 / 5, Movitec V ,5 1,5 / 5, Movitec V ,5 13,6 / 7, Movitec V ,5 13,6 / 7, Movitec V , 19,47 / 11, Movitec V , 19,47 / 11, pole Movitec V ,55 2,34 / 1, Movitec V ,55 2,34 / 1, Movitec V ,55 2,34 / 1, Movitec V ,55 2,34 / 1, Movitec V ,55 2,34 / 1, Movitec V ,75 3,9 / 1, Movitec V ,75 3,9 / 1, Movitec V ,1 4,71 / 2, Movitec V ,1 4,71 / 2, Movitec V ,1 4,71 / 2, Movitec V ,5 5,61 / 3, Movitec V ,5 5,61 / 3, Movitec V ,2 8,9 / 4, Movitec V ,2 8,9 / 4, Movitec B 19

20 Movitec VF, "easy access" mechanical seal, 3~23/4 V, 3~4/69 V Movitec VF, "easy access" mechanical seal, with KSB standard motor IE2 2), fixed/variable speed - 3~23/4 V up to 2.2 kw, for 3 kw and higher 3~4/69 V Size Number of stages Shaft seal code Motor rating Max. current Movitec VF Fixed speed Movitec VF Variable speed [kw] [] Mat. No. [kg] Mat. No. [kg] 2-pole Movitec VF ,37 1,64 /, Movitec VF ,37 1,64 /, Movitec VF ,37 1,64 /, Movitec VF ,37 1,64 /, Movitec VF ,55 2,31 / 1, Movitec VF ,55 2,31 / 1, Movitec VF ,55 2,31 / 1, Movitec VF ,75 2,99 / 1, Movitec VF ,75 2,99 / 1, Movitec VF ,1 4,22 / 2, Movitec VF ,1 4,22 / 2, Movitec VF ,1 4,22 / 2, Movitec VF ,5 5,5 / 2, Movitec VF ,5 5,5 / 2, Movitec VF ,5 5,5 / 2, Movitec VF ,2 7,25 / 4, Movitec VF ,2 7,25 / 4, Movitec VF ,2 7,25 / 4, Movitec VF ,2 7,25 / 4, Movitec VF ,2 7,25 / 4, Movitec VF ,37 1,64 /, Movitec VF ,55 2,31 / 1, Movitec VF ,55 2,31 / 1, Movitec VF ,75 2,99 / 1, Movitec VF ,1 4,22 / 2, Movitec VF ,1 4,22 / 2, Movitec VF ,5 5,5 / 2, Movitec VF ,5 5,5 / 2, Movitec VF ,5 5,5 / 2, Movitec VF ,2 7,25 / 4, Movitec VF ,2 7,25 / 4, Movitec VF ,2 7,25 / 4, Movitec VF , 5,55 / 3, Movitec VF , 5,55 / 3, Movitec VF , 5,55 / 3, Movitec VF , 7,29 / 4, Movitec VF , 7,29 / 4, Movitec VF , 7,29 / 4, Movitec VF ,37 1,64 /, Movitec VF ,75 2,99 / 1, Movitec VF ,1 4,22 / 2, Movitec VF ,1 4,22 / 2, Movitec VF ,5 5,5 / 2, Movitec VF ,5 5,5 / 2, Movitec VF ,2 7,25 / 4, Movitec VF ,2 7,25 / 4, Movitec VF ,2 7,25 / 4, Movitec VF , 5,55 / 3, Movitec VF , 5,55 / 3, Movitec VF , 5,55 / 3, Movitec VF , 7,29 / 4, ) IE2 for motor ratings.75 kw 2 Movitec B

21 Size Number of stages Shaft seal code Motor rating Max. current Movitec VF Fixed speed Movitec VF Variable speed [kw] [] Mat. No. [kg] Mat. No. [kg] Movitec VF , 7,29 / 4, Movitec VF ,5 1,7 / 5, Movitec VF ,5 1,7 / 5, Movitec VF ,5 1,7 / 5, Movitec VF ,5 1,7 / 5, Movitec VF ,5 1,7 / 5, Movitec VF ,5 13,6 / 7, Movitec VF ,5 13,6 / 7, Movitec VF ,5 13,6 / 7, Movitec VF ,1 4,22 / 2, Movitec VF ,2 7,25 / 4, Movitec VF , 5,55 / 3, Movitec VF , 7,25 / 4, Movitec VF ,5 1,7 / 5, Movitec VF ,5 1,7 / 5, Movitec VF ,5 13,6 / 7, Movitec VF ,5 13,6 / 7, Movitec VF , 19,47 / 11, Movitec VF , 19,47 / 11, Movitec VF , 19,47 / 11, Movitec VF , 26,35 / 15, Movitec VF , 26,35 / 15, Movitec VF , 26,35 / 15, Movitec VF ,2 7,25 / 4, Movitec VF , 7,25 / 4, Movitec VF ,5 1,7 / 5, Movitec VF ,5 13,6 / 7, Movitec VF , 19,47 / 11, Movitec VF , 19,47 / 11, Movitec VF , 26,35 / 15, Movitec VF , 26,35 / 15, Movitec VF , 26,35 / 15, Movitec VF ,5 33,7 / 23, Movitec VF ,5 33,7 / 23, Movitec VF , 39,8 / 23, pole Movitec VF ,55 2,34 / 1, Movitec VF ,55 2,34 / 1, Movitec VF ,55 2,34 / 1, Movitec VF ,55 2,34 / 1, Movitec VF ,55 2,34 / 1, Movitec VF ,75 3,9 / 1, Movitec VF ,75 3,9 / 1, Movitec VF ,1 4,71 / 2, Movitec VF ,1 4,71 / 2, Movitec VF ,1 4,71 / 2, Movitec VF ,5 5,61 / 3, Movitec VF ,5 5,61 / 3, Movitec VF ,2 8,19 / 4, Movitec VF ,2 8,19 / 4, Movitec VF ,1 4,71 / 2, Movitec VF ,1 4,71 / 2, Movitec VF ,1 4,71 / 2, Movitec VF ,1 4,71 / 2, Movitec VF ,1 4,71 / 2, Movitec VF ,5 5,61 / 3, Movitec VF ,5 5,61 / 3, Movitec B 21

22 Size Number of stages Shaft seal code Motor rating Max. current Movitec VF Fixed speed Movitec VF Variable speed [kw] [] Mat. No. [kg] Mat. No. [kg] Movitec VF ,2 8,19 / 4, Movitec VF ,2 8,19 / 4, Movitec VF ,2 8,19 / 4, Movitec VF ,2 8,19 / 4, Movitec VF , 8,19 / 4, Movitec VCF, "easy access" mechanical seal, 3~23/4 V, 3~4/69 V Movitec VCF, "easy access" mechanical seal, with KSB standard motor IE2 21), fixed/variable speed - 3~23/4 V up to 2.2 kw, for 3 kw and higher 3~4/69 V Size Number of stages Shaft seal code Motor rating Max. current Movitec VCF Fixed speed Movitec VCF Variable speed [kw] [] Mat. No. [kg] Mat. No. [kg] 2-pole Movitec VCF ,37 1,64 /, Movitec VCF ,37 1,64 /, Movitec VCF ,37 1,64 /, Movitec VCF ,37 1,64 /, Movitec VCF ,55 2,31 / 1, Movitec VCF ,55 2,31 / 1, Movitec VCF ,55 2,31 / 1, Movitec VCF ,75 2,99 / 1, Movitec VCF ,75 2,99 / 1, Movitec VCF ,1 4,22 / 2, Movitec VCF ,1 4,22 / 2, Movitec VCF ,1 4,22 / 2, Movitec VCF ,5 5,5 / 2, Movitec VCF ,5 5,5 / 2, Movitec VCF ,5 5,5 / 2, Movitec VCF ,2 7,25 / 4, Movitec VCF ,2 7,25 / 4, Movitec VCF ,2 7,25 / 4, Movitec VCF ,2 7,25 / 4, Movitec VCF ,2 7,25 / 4, Movitec VCF ,37 1,64 /, Movitec VCF ,55 2,31 / 1, Movitec VCF ,55 2,31 / 1, Movitec VCF ,75 2,99 / 1, Movitec VCF ,1 4,22 / 2, Movitec VCF ,1 4,22 / 2, Movitec VCF ,5 5,5 / 2, Movitec VCF ,5 5,5 / 2, Movitec VCF ,5 5,5 / 2, Movitec VCF ,2 7,25 / 4, Movitec VCF ,2 7,25 / 4, Movitec VCF ,2 7,25 / 4, Movitec VCF , 5,55 / 3, Movitec VCF , 5,55 / 3, Movitec VCF , 5,55 / 3, Movitec VCF , 7,29 / 4, Movitec VCF , 7,29 / 4, Movitec VCF , 7,29 / 4, Movitec VCF ,37 1,64 /, Movitec VCF ,75 2,99 / 1, ) IE2 for motor ratings.75 kw 22 Movitec B

23 Size Number of stages Shaft seal code Motor rating Max. current Movitec VCF Fixed speed Movitec VCF Variable speed [kw] [] Mat. No. [kg] Mat. No. [kg] Movitec VCF ,1 4,22 / 2, Movitec VCF ,1 4,22 / 2, Movitec VCF ,5 5,5 / 2, Movitec VCF ,5 5,5 / 2, Movitec VCF ,2 7,25 / 4, Movitec VCF ,2 7,25 / 4, Movitec VCF ,2 7,25 / 4, Movitec VCF , 5,55 / 3, Movitec VCF , 5,55 / 3, Movitec VCF , 5,55 / 3, Movitec VCF , 7,29 / 4, Movitec VCF , 7,29 / 4, Movitec VCF ,5 1,7 / 5, Movitec VCF ,5 1,7 / 5, Movitec VCF ,5 1,7 / 5, Movitec VCF ,5 1,7 / 5, Movitec VCF ,75 2,99 / 1, Movitec VCF ,75 2,99 / 1, Movitec VCF ,1 4,22 / 2, Movitec VCF ,5 5,5 / 2, Movitec VCF ,2 7,25 / 4, Movitec VCF ,2 7,25 / 4, Movitec VCF , 5,55 / 3, Movitec VCF , 5,55 / 3, Movitec VCF , 7,25 / 4, Movitec VCF , 7,25 / 4, Movitec VCF , 7,25 / 4, Movitec VCF ,5 1,7 / 5, Movitec VCF ,5 1,7 / 5, Movitec VCF ,5 13,6 / 7, Movitec VCF ,5 13,6 / 7, Movitec VCF ,5 13,6 / 7, Movitec VCF ,1 4,22 / 2, Movitec VCF ,2 7,25 / 4, Movitec VCF , 5,55 / 3, Movitec VCF , 7,25 / 4, Movitec VCF ,5 1,7 / 5, Movitec VCF ,5 1,7 / 5, Movitec VCF ,5 13,6 / 7, Movitec VCF ,5 13,6 / 7, Movitec VCF , 19,47 / 11, Movitec VCF , 19,47 / 11, Movitec VCF , 19,47 / 11, Movitec VCF , 26,35 / 15, Movitec VCF , 26,35 / 15, Movitec VCF , 26,35 / 15, Movitec VCF ,2 7,25 / 4, Movitec VCF , 7,25 / 4, Movitec VCF ,5 1,7 / 5, Movitec VCF ,5 13,6 / 7, Movitec VCF , 19,47 / 11, Movitec VCF , 19,47 / 11, Movitec VCF , 26,35 / 15, Movitec VCF , 26,35 / 15, Movitec VCF , 26,35 / 15, Movitec VCF ,5 33,7 / 23, Movitec VCF ,5 33,7 / 23, Movitec VCF , 39,8 / 23, Movitec B 23

24 Size Number of stages Shaft seal code Motor rating Max. current Movitec VCF Fixed speed Movitec VCF Variable speed [kw] [] Mat. No. [kg] Mat. No. [kg] 4-pole Movitec VCF ,55 2,34 / 1, Movitec VCF ,55 2,34 / 1, Movitec VCF ,55 2,34 / 1, Movitec VCF ,55 2,34 / 1, Movitec VCF ,55 2,34 / 1, Movitec VCF ,75 3,9 / 1, Movitec VCF ,75 3,9 / 1, Movitec VCF ,1 4,71 / 2, Movitec VCF ,1 4,71 / 2, Movitec VCF ,1 4,71 / 2, Movitec VCF ,5 5,61 / 3, Movitec VCF ,5 5,61 / 3, Movitec VCF ,2 8,19 / 4, Movitec VCF ,2 8,19 / 4, Movitec VCF ,1 4,71 / 2, Movitec VCF ,1 4,71 / 2, Movitec VCF ,1 4,71 / 2, Movitec VCF ,1 4,71 / 2, Movitec VCF ,1 5,61 / 3, Movitec VCF ,5 5,61 / 3, Movitec VCF ,5 5,61 / 3, Movitec VCF ,2 8,19 / 4, Movitec VCF ,2 8,19 / 4, Movitec VCF ,2 8,19 / 4, Movitec VCF ,2 8,19 / 4, Movitec VCF , 8,19 / 4, Movitec VS, "easy access" mechanical seal, 3~23/4 V, 3~4/69 V Movitec VS, "easy access" mechanical seal, with KSB standard motor IE2 22), fixed/variable speed - 3~23/4 V up to 2.2 kw, for 3 kw and higher 3~4/69 V Size Number of stages Shaft seal code Motor rating Max. current Oval flange Movitec VS Fixed speed Oval flange Movitec VS Variable speed [kw] [] Mat. No. [kg] Mat. No. [kg] 2-pole Movitec VS ,37 1,64 /, Movitec VS ,37 1,64 /, Movitec VS ,37 1,64 /, Movitec VS ,37 1,64 /, Movitec VS ,55 2,31 / 1, Movitec VS ,55 2,31 / 1, Movitec VS ,55 2,31 / 1, Movitec VS ,75 2,99 / 1, Movitec VS ,75 2,99 / 1, Movitec VS ,1 4,22 / 2, Movitec VS ,1 4,22 / 2, Movitec VS ,1 4,22 / 2, Movitec VS ,5 5,5 / 2, Movitec VS ,5 5,5 / 2, Movitec VS ,37 1,64 /, Movitec VS ,55 2,31 / 1, Movitec VS ,55 2,31 / 1, Movitec VS ,75 2,99 / 1, ) IE2 for motor ratings.75 kw 24 Movitec B

25 Size Number of stages Shaft seal code Motor rating Max. current Oval flange Movitec VS Fixed speed Oval flange Movitec VS Variable speed [kw] [] Mat. No. [kg] Mat. No. [kg] Movitec VS ,1 4,22 / 2, Movitec VS ,1 4,22 / 2, Movitec VS ,5 5,5 / 2, Movitec VS ,5 5,5 / 2, Movitec VS ,5 5,5 / 2, Movitec VS ,2 7,25 / 4, Movitec VS ,2 7,25 / 4, Movitec VS ,2 7,25 / 4, Movitec VS , 5,55 / 3, Movitec VS ,37 1,64 /, Movitec VS ,75 2,99 / 1, Movitec VS ,1 4,22 / 2, Movitec VS ,1 4,22 / 2, Movitec VS ,5 5,5 / 2, Movitec VS ,5 5,5 / 2, Movitec VS ,2 7,25 / 4, Movitec VS ,2 7,25 / 4, Movitec VS ,2 7,25 / 4, Movitec VS , 5,55 / 3, Movitec VS , 5,55 / 3, Movitec VS , 5,55 / 3, Movitec VS , 7,29 / 4, Movitec VS ,75 2,99 / 1, Movitec VS ,75 2,99 / 1, Movitec VS ,1 4,22 / 2, Movitec VS ,5 5,5 / 2, Movitec VS ,2 7,25 / 4, Movitec VS ,2 7,25 / 4, Movitec VS , 5,55 / 3, Movitec VS , 5,55 / 3, Movitec VS , 7,25 / 4, Movitec VS , 7,25 / 4, Movitec VS , 7,25 / 4, Movitec VS ,5 1,7 / 5, Movitec VS ,1 4,22 / 2, Movitec VS ,2 7,25 / 4, Movitec VS , 5,55 / 3, Movitec VS , 7,25 / 4, Movitec VS ,5 1,7 / 5, Movitec VS ,5 1,7 / 5, Movitec VS ,5 13,6 / 7, Movitec VS ,5 13,6 / 7, Movitec VS , 19,47 / 11, Movitec VS , 19,47 / 11, pole Movitec VS ,55 2,34 / 1, Movitec VS ,55 2,34 / 1, Movitec VS ,55 2,34 / 1, Movitec VS ,55 2,34 / 1, Movitec VS ,55 2,34 / 1, Movitec VS ,75 3,9 / 1, Movitec VS ,75 3,9 / 1, Movitec VS ,1 4,71 / 2, Movitec VS ,1 4,71 / 2, Movitec VS ,1 4,71 / 2, Movitec VS ,5 5,61 / 3, Movitec VS ,5 5,61 / 3, Movitec B 25

26 Size Number of stages Shaft seal code Motor rating Max. current Oval flange Movitec VS Fixed speed Oval flange Movitec VS Variable speed [kw] [] Mat. No. [kg] Mat. No. [kg] Movitec VS ,2 8,19 / 4, Movitec VS ,2 8,19 / 4, Movitec VSF, "easy access" mechanical seal, 3~23/4 V, 3~4/69 V Movitec VSF, "easy access" mechanical seal, with KSB standard motor IE2 23), fixed/variable speed - 3~23/4 V up to 2.2 kw, for 3 kw and higher 3~4/69 V Size Number of stages Shaft seal code Motor rating Max. current Movitec VSF Fixed speed Movitec VSF Variable speed [kw] [] Mat. No. [kg] Mat. No. [kg] 2-pole Movitec VSF ,5 5,5 / 2, Movitec VSF ,2 7,25 / 4, Movitec VSF ,2 7,25 / 4, Movitec VSF ,2 7,25 / 4, Movitec VSF ,2 7,25 / 4, Movitec VSF ,2 7,25 / 4, Movitec VSF ,37 1,64 /, Movitec VSF ,55 2,31 / 1, Movitec VSF ,55 2,31 / 1, Movitec VSF ,75 2,99 / 1, Movitec VSF ,1 4,22 / 2, Movitec VSF ,1 4,22 / 2, Movitec VSF ,5 5,5 / 2, Movitec VSF ,5 5,5 / 2, Movitec VSF ,5 5,5 / 2, Movitec VSF ,2 7,25 / 4, Movitec VSF ,2 7,25 / 4, Movitec VSF ,2 7,25 / 4, Movitec VSF , 5,55 / 3, Movitec VSF , 5,55 / 3, Movitec VSF , 5,55 / 3, Movitec VSF , 7,29 / 4, Movitec VSF , 7,29 / 4, Movitec VSF , 7,29 / 4, Movitec VSF ,37 1,64 /, Movitec VSF ,75 2,99 / 1, Movitec VSF ,1 4,22 / 2, Movitec VSF ,1 4,22 / 2, Movitec VSF ,5 5,5 / 2, Movitec VSF ,5 5,5 / 2, Movitec VSF ,2 7,25 / 4, Movitec VSF ,2 7,25 / 4, Movitec VSF ,2 7,25 / 4, Movitec VSF , 5,55 / 3, Movitec VSF , 5,55 / 3, Movitec VSF , 5,55 / 3, Movitec VSF , 7,29 / 4, Movitec VSF , 7,29 / 4, Movitec VSF ,5 1,7 / 5, Movitec VSF ,5 1,7 / 5, Movitec VSF ,5 1,7 / 5, Movitec VSF ,5 1,7 / 5, ) IE2 for motor ratings.75 kw 26 Movitec B

27 Size Number of stages Shaft seal code Motor rating Max. current Movitec VSF Fixed speed Movitec VSF Variable speed [kw] [] Mat. No. [kg] Mat. No. [kg] Movitec VSF ,5 1,7 / 5, Movitec VSF ,5 13,6 / 7, Movitec VSF ,5 13,6 / 7, Movitec VSF ,5 13,6 / 7, Movitec VSF ,1 4,22 / 2, Movitec VSF ,2 7,25 / 4, Movitec VSF , 5,55 / 3, Movitec VSF , 7,25 / 4, Movitec VSF ,5 1,7 / 5, Movitec VSF ,5 1,7 / 5, Movitec VSF ,5 13,6 / 7, Movitec VSF ,5 13,6 / 7, Movitec VSF , 19,47 / 11, Movitec VSF , 19,47 / 11, Movitec VSF , 19,47 / 11, Movitec VSF , 26,35 / 15, Movitec VSF , 26,35 / 15, Movitec VSF , 26,35 / 15, Movitec VSF ,2 7,25 / 4, Movitec VSF , 7,25 / 4, Movitec VSF ,5 1,7 / 5, Movitec VSF ,5 13,6 / 7, Movitec VSF , 19,47 / 11, Movitec VSF , 19,47 / 11, Movitec VSF , 26,35 / 15, Movitec VSF , 26,35 / 15, Movitec VSF , 26,35 / 15, Movitec VSF ,5 33,7 / 23, Movitec VSF ,5 33,7 / 23, Movitec VSF , 39,8 / 23, pole Movitec VSF ,55 2,34 / 1, Movitec VSF ,55 2,34 / 1, Movitec VSF ,55 2,34 / 1, Movitec VSF ,55 2,34 / 1, Movitec VSF ,55 2,34 / 1, Movitec VSF ,75 3,9 / 1, Movitec VSF ,75 3,9 / 1, Movitec VSF ,1 4,71 / 2, Movitec VSF ,1 4,71 / 2, Movitec VSF ,1 4,71 / 2, Movitec VSF ,5 5,61 / 3, Movitec VSF ,5 5,61 / 3, Movitec VSF ,2 8,19 / 4, Movitec VSF ,2 8,19 / 4, Movitec VSF ,1 4,71 / 2, Movitec VSF ,1 4,71 / 2, Movitec VSF ,1 4,71 / 2, Movitec VSF ,1 4,71 / 2, Movitec VSF ,1 4,71 / 2, Movitec VSF ,5 5,61 / 3, Movitec VSF ,5 5,61 / 3, Movitec VSF ,2 8,19 / 4, Movitec VSF ,2 8,19 / 4, Movitec VSF ,2 8,19 / 4, Movitec VSF ,2 8,19 / 4, Movitec VSF , 8,19 / 4, Movitec B 27

28 Movitec VCF 9, "easy access" mechanical seal, 3~4/69 V Movitec VCF 9, "easy access" mechanical seal, fixed/variable speed - 3~4/69 V Size Number of stages Motor size Shaft seal code Motor rating Max. current Movitec VCF Fixed speed Movitec VCF Variable speed [kw] [] Mat. No. [kg] Mat. No. [kg] 2-pole Movitec VCF ,5 1,7 / 6, Movitec VCF ,5 14,3 / 8, Movitec VCF M 23 11, 2,3 / 11, Movitec VCF M 23 15, 26,7 / 15, Movitec VCF M 23 15, 26,7 / 15, Movitec VCF L 23 18,5 33,7 / 23, Movitec VCF M 23 22, 39,8 / 23, Movitec VCF M 23 22, 39,8 / 23, Movitec VCF L 23 3, 52,8 / 3, Movitec VCF L 23 3, 52,8 / 3, Movitec VCF 9 4 2L 23 3, 52,8 / 3, Movitec VCF L 23 37, 64,5 / 37, Movitec VCF L 23 37, 64,5 / 37, Movitec VCF 9 5 2L 23 37, 64,5 / 37, Movitec VCF M 23 45, 78,2 / 45, Movitec VCF M 23 45, 78,2 / 45, Movitec VCF M 23 45, 78,2 / 45, Movitec VF 9, "easy access" mechanical seal, 3~4/69 V Movitec VF 9, "easy access" mechanical seal, fixed/variable speed - 3~4/69 V Size Number of stages Motor size Shaft seal code Motor rating Max. current Movitec VF Fixed speed Movitec VF Variable speed [kw] [] Mat. No. [kg] Mat. No. [kg] 2-pole Movitec VF ,5 1,7 / 6, Movitec VF ,5 14,3 / 8, Movitec VF M 13 11, 2,3 / 11, Movitec VF M 13 15, 26,7 / 15, Movitec VF M 13 15, 26,7 / 15, Movitec VF L 13 18,5 33,7 / 19, Movitec VF M 13 22, 39,8 / 23, Movitec VF M 13 22, 39,8 / 23, Movitec VF L 13 3, 52,8 / 3, Movitec VF L 13 3, 52,8 / 3, Movitec VF 9 4 2L 13 3, 52,8 / 3, Movitec VF L 13 37, 64,5 / 37, Movitec VF L 13 37, 64,5 / 37, Movitec VF 9 5 2L 13 37, 64,5 / 37, Movitec VF M 13 45, 78,2 / 45, Movitec VF M 13 45, 78,2 / 45, Movitec VF M 13 45, 78,2 / 45, Movitec VSF 9, "easy access" mechanical seal, 3~4/69 V Movitec VSF 9, "easy access" mechanical seal, fixed/variable speed - 3~4/69 V Size Number of stages Motor size Shaft seal code Motor rating Max. current Movitec VSF Fixed speed Movitec VSF Variable speed [kw] [] Mat. No. [kg] Mat. No. [kg] 2-pole Movitec VSF ,5 1,7 / 6, Movitec VSF ,5 14,3 / 8, Movitec VSF M 14 11, 2,3 / 11, Movitec VSF M 14 15, 26,7 / 15, Movitec B

29 High-pressure pumps Size Number of Motor size stages Movitec VSF 9 Movitec VSF 9 Movitec VSF 9 Movitec VSF 9 Movitec VSF 9 Movitec VSF 9 Movitec VSF 9 Movitec VSF 9 Movitec VSF 9 Movitec VSF 9 Movitec VSF 9 Movitec VSF 9 Movitec VSF M 16L 18M 18M 2L 2L 2L 2L 2L 2L 225M 225M 225M Shaft seal code Motor rating Max. current [kw] 15, 18,5 22, 22, 3, 3, 3, 37, 37, 37, 45, 45, 45, [] 26,7 / 15,4 33,7 / 19,5 39,8 / 23, 39,8 / 23, 52,8 / 3,5 52,8 / 3,5 52,8 / 3,5 64,5 / 37,3 64,5 / 37,3 64,5 / 37,3 78,2 / 45,2 78,2 / 45,2 78,2 / 45,2 Movitec VSF Movitec VSF Fixed speed Variable speed Mat. No [kg] Mat. No [kg] Types of connection Version B Description Oval flange Movitec V Standard Movitec VS ISO 228/-1 Material Max. PN 16 pressure class Movitec VF Movitec VCF Movitec VSF EN 192-1/EN SME B 16.1 JIS JS 13 JL 14 PN External thread Movitec V(M)E Victaulic coupling Movitec VV/VMV/VSV Tri-clamp coupling Movitec VT/ VST/VMT ISO DIN JS 13 PN PN PN 16 Terminal box positions Top view of terminal box positions P3 = Position 3 Standard Movitec V/ Standard Movitec VS P6 = Position 6 Movitec B 29

30 P9 = Position 9 Standard Movitec VME P12 = Position 12 Not for Movitec VME Selection charts Movitec B; n = 29 rpm 5 [US.gpm] [IM.gpm] V(S) 2 V(S) 4 V(S) 6 V(S) 1 V(S) 15 V(S) 25 V(S) 9 VC H [m] [ft] Q [m 3 /h] [l/s] Movitec B

31 Movitec B; n = 145 rpm 5 [US.gpm] [IM.gpm] V(S) 9 VC 9 1 V(S) 1 V(S) 15 V(S) [ft] H [m] Q [m 3 /h] [l/s] Characteristic curves The characteristic curves are based on the following principles: Tolerances to ISO 996 Class 2 / nnex The characteristic curves were measured under the following conditions: Motor used: Standardised KSB motor with integrated frequency inverter Fluid properties: Deaerated water Temperature: 2 C Density: 1. kg/dm³ Kinematic viscosity: 1 mm²/s Movitec B 31

32 n = 29 rpm Movitec B; 2; n = 29 rpm Q [US.gpm] Q [IM.gpm] 8 St=3 St=28 2 St=26 St=24 6 St=22 15 St=2 St=18 St= H [m] St=14 St=12 St=11 St=1 St=9 St=8 St=7 St=6 St=5 St=4 St=3 St=2 H [ft] 2..5 Q [m³/h] NPSH R [m] 8..2 Q [l/s] NPSH R [ft] 6 Eta [%].8 P [kw].5.2 St=1..5 Q [m³/h] K952/2.1 P [hp].4 St = Number of stages The power input P is indicated per stage 32 Movitec B

33 Movitec B; 4; n = 29 rpm Q [US.gpm] Q [IM.gpm] 8 St=26 St=24 2 St=22 St= St=18 St=16 St= H [m] St=12 St=11 St=1 St=9 St=8 St=7 St=6 St=5 St=4 St=3 St=2 H [ft] Q [m³/h] Q [l/s] NPSH R [m] 8 NPSH R [ft] Eta [%].15.2 P [kw] St=1 P [hp]. 1 Q [m³/h] K954/2. St = Number of stages The power input P is indicated per stage Movitec B 33

34 Movitec B; 6; n = 29 rpm Q [US.gpm] Q [IM.gpm] 25 St=26 8 St=24 2 St=22 St=2 St= St= H [m] St=14 St=12 St=11 St=1 St=9 St=8 St=7 St=6 St=5 St=4 St=3 St=2 4 H [ft] 2 2 Q [m³/h] NPSH R [m] Q [l/s] NPSH R [ft] Eta [%] P [kw].2.5 St=1 2 Q [m³/h] K956/2.3 P [hp].1 St = Number of stages The power input P is indicated per stage 34 Movitec B

35 Movitec B; 1; n = 29 rpm Q [US.gpm] Q [IM.gpm] 8 St=21 2 St=19 St=17 6 St=15 15 St= H [m] St=11 St=1 St=9 St=8 St=7 St=6 St=5 St=4 St=3 St=2 St=1 4 H [ft] 2 2 Q [m³/h] Q [l/s] NPSH R [m] 8 NPSH R [ft] Eta [%].4 P [kw].5 P [hp].1 St=1 2 Q [m³/h] Mov1TNG29/2.2 St = Number of stages The power input P is indicated per stage Movitec B 35

36 Movitec B; 15; n = 29 rpm Q [US.gpm] Q [IM.gpm] 25 St= St=15 St= St=11 St=1 1 5 H [m] St=9 St=8 St=7 St=6 St=5 St=4 St=3 St=2 St=1 4 H [ft] 2 NPSH R [m] Q [m³/h] Q [l/s] NPSH [ft] R Eta [%] P [kw] 1.2 St=1 5 Q [m³/h] P [hp].5 Mov15TNG29/2 St = Number of stages The power input P is indicated per stage 36 Movitec B

37 Movitec B; 25, n = 29 rpm Q [US.gpm] 5 1 Q [IM.gpm] 25 St=12 8 St=11 2 St=1 St= St=8 St=7 St=6 4 1 St=5 St=4 H [ft] 5 St=3 St=2 2 H [m] St=1 5 Q [m³/h] Q [l/s] NPSH req. NPSH R [m] 1 NPSH [ft] R Eta [%] 1.8 P [kw] 2 P [hp] 1 St=1 5 Q [m³/h] Kraugot// /4 St = Number of stages The power input P is indicated per stage Movitec B 37

38 Movitec B; 9; n = 29 rpm Q [US.gpm] Q [IM.gpm] 16 St= St= St=4 3 8 St= St=2 St=1 H [ft] 1 H [m] 2 Q [m³/h] NPSH R [m] Q [l/s] NPSH R [ft] Eta [%] P [kw] 5 8 P [hp] 2 St=1 2 Q [m³/h] Mov9_29_1/ 4 St = Number of stages The power input P is indicated per stage 38 Movitec B

39 n = 145 rpm Movitec B; 1; n = 145 rpm Q [US.gpm] Q [IM.gpm] St= St=19 St= St=15 St= H [m] St=11 St=1 St=9 St=8 St=7 St=6 St=5 St=4 St=3 St=2 St=1 1 H [ft] 5 1 Q [m³/h] NPSH R [m]..5 Q [l/s] NPSH R [ft] 8 Eta [%] P [kw] St=1 1 Q [m³/h] Mov1TNG145/2 P [hp].2 St = Number of stages The power input P is indicated per stage Movitec B 39

40 Movitec B; 15; n = 145 rpm Q [US.gpm] Q [IM.gpm] 6 St= St=15 St= St=11 St=1 3 St=9 St=8 1 2 St=7 St=6 St=5 St=4 H [ft] 5 1 H [m] St=3 St=2 St=1 2 Q [m³/h] NPSH [m] 1 R.2 1 Q [l/s] NPSH R [ft] 8 Eta [%] P [kw].1.15 P [hp].2 St=1 2 Q [m³/h] Mov15TNG145/2.5 St = Number of stages The power input P is indicated per stage 4 Movitec B

41 Movitec B; 25, n = 145 rpm Q [US.gpm] Q [IM.gpm] 6 St=12 2 St=11 5 St=1 St= St=8 St=7 3 St=6 1 2 St=5 St=4 H [ft] St=3 5 1 St=2 H [m] St=1 1.5 NPSH R [m] 1 2 Q [m³/h] Q [l/s] NPSH req. 4 NPSH [ft] R Eta [%].2 P [hp] P [kw].2.1 St=1 2 Q [m³/h] Kraugot/ /3 St = Number of stages The power input P is indicated per stage Movitec B 41

42 Movitec B; 9; n = 145 rpm Q [US.gpm] Q [IM.gpm] 4 St= St=5 3 1 H [ft] H [m] Q [m³/h] Q [l/s] 1 15 NPSH R [m] 8 NPSH R [ft] Eta [%] P [kw] 5 2 St=6 St=5 1 Q [m³/h] Mov9_145_1/ 8 4 P [hp] 42 Movitec B

43 Dimensions Movitec B, V 2, n = 29 rpm E2 E1 Movitec V/ Movitec VS Oval flange Size: G x Ø13 G 1 G Movitec VV/ Movitec VSV Victaulic Size: x Ø13 Ø Ø42 F1 Movitec VT/ Movitec VST Tri-clamp Size: DN x Ø13 Ø5, Ø5,5 Ø115 Ø85 Ø7 F2 G 3/8 P Movitec VF/ Movitec VSF Size: DN x Ø x Ø13 DN 25 DN Ø115 Movitec VCF Size: DN 25 Ø85 Ø68 4x Ø14 DN 25 DN x Ø Dimensions V 2 E1 E2 P 24) Oval flange/ Tri-clamp/ Victaulic F1 F2 F1 F2 Stages V 2 E1 E2 P Oval flange/ Tri-clamp/ Victaulic F1 F2 F1 F2 Stages ) Dimensions relevant for motors > 5.5 kw Movitec B 43

44 Movitec B, V 4, n = 29 rpm E2 E1 Movitec V/ Movitec VS Oval flange Size: G x Ø13 G 1 G Movitec VV/ Movitec VSV Victaulic Size: x Ø13 Ø Ø42 F1 Movitec VT/ Movitec VST Tri-clamp Size: DN x Ø13 Ø5, Ø5,5 Ø115 Ø85 Ø7 F2 G 3/8 P Movitec VF/ Movitec VSF Size: DN x Ø x Ø13 DN 25 DN Ø115 Movitec VCF Size: DN 25 Ø85 Ø68 4x Ø14 DN 25 DN x Ø Dimensions V 4 E1 E2 P 25) ] Oval flange/ Tri-clamp/ Victaulic F1 F2 F1 F2 Stages V 4 E1 E2 P] Oval flange/ Tri-clamp/ Victaulic F1 F2 F1 F2 Stages ) Dimensions relevant for motors > 5.5 kw 44 Movitec B

45 Movitec B, V 6, n = 29 rpm E2 E1 Movitec V/ Movitec VS Oval flange Size: G 1 1 / x Ø13 G 1 G Movitec VV/ Movitec VSV Victaulic Size: x Ø13 Ø Ø42 F1 Movitec VT/ Movitec VST Tri-clamp Size: DN x Ø13 Ø5, Ø5,5 Ø115 F2 G 3/8 P Movitec VF/ Movitec VSF Size: DN 32 Movitec VCF Size: DN 32 Ø85 Ø Ø115 Ø85 Ø68 4x Ø x Ø13 4x Ø14 75 DN 25 DN DN 25 DN x Ø Dimensions V 6 E1 E2 P 26) Oval flange/ Tri-clamp/ Victaulic F1 F2 F1 F2 Stages V 6 E1 E2 P Oval flange/ Tri-clamp/ Victaulic F1 F2 F1 F2 Stages ) Dimensions relevant for motors > 5.5 kw Movitec B 45

46 Movitec B, V 1, n = 145 rpm E2 E1 Movitec V/ Movitec VS Oval flange Size: G 1 ½ Ø15 Ø11 Ø x Ø19 8 4x Ø14 DN 4 DN Movitec VV/ Movitec VSV Victaulic 215 Size: x Ø14 Ø6,3 Ø6, F1 Movitec VT/ Movitec VST Ø64 8 Tri-clamp 215 4x Ø14 13 Size: DN Ø64 Ø15 Ø11 F2 G 3/8 P Movitec VF/ Movitec VSF Size: DN 4 Ø x Ø19 DN 4 DN 4 8 4x Ø Ø15 Ø11 Ø85 Movitec VCF Size: DN x Ø19 8 4x Ø14 DN 4 DN Dimensions V 1 E1 E2 P 27) Oval flange/ Tri-clamp/ Victaulic F1 F2 F1 F2 Stages ) Dimensions relevant for motors > 5.5 kw 46 Movitec B

47 Movitec B, V 1, n = 29 rpm E2 E1 Movitec V/ Movitec VS Oval flange Size: G 1 ½ Ø15 Ø11 Ø x Ø19 8 4x Ø14 DN 4 DN Movitec VV/ Movitec VSV Victaulic 215 Size: x Ø14 Ø6,3 Ø6, F1 Movitec VT/ Movitec VST Ø64 8 Tri-clamp 215 4x Ø14 13 Size: DN Ø64 Ø15 Ø11 F2 G 3/8 P Movitec VF/ Movitec VSF Size: DN 4 Ø x Ø19 DN 4 DN 4 8 4x Ø Ø15 Ø11 Ø85 Movitec VCF Size: DN x Ø19 8 4x Ø14 DN 4 DN Dimensions V 1 E1 E2 P 28) Oval flange/ Tri-clamp/ Victaulic F1 F2 F1 F2 Stages ) Dimensions relevant for motors > 5.5 kw Movitec B 47

48 Movitec B, V 15, n = 145 rpm E2 E1 Movitec V/ Movitec VS Oval flange 1 Size: G Option 9 8 4x Ø14 G G Movitec VV/ Movitec VSV Victaulic 215 Size: x Ø14 Ø6, Ø6,3 261 F1 Movitec VT/ Ø64 Movitec VST 8 Tri-clamp 215 4x Ø14 13 Size: DN Ø165 2 Ø64 F2 G 3/8 P Movitec VF/ Movitec VSF Size: DN 5 Ø125 Ø Ø165 4x Ø19 DN 5 DN 5 8 4x Ø Movitec VCF Size: DN 5 Ø125 Ø1 4x Ø19 DN 5 DN x Ø Dimensions V 15 E1 E2 P 29) Oval flange/ Tri-clamp/ Victaulic F1 F2 F1 F2 Stages ) Dimensions relevant for motors > 5.5 kw 48 Movitec B

49 Movitec B, V 15, n = 29 rpm E2 E1 Movitec V/ Movitec VS Oval flange 1 Size: G Option 9 8 4x Ø14 G G Movitec VV/ Movitec VSV Victaulic 215 Size: x Ø14 Ø6, Ø6,3 261 F1 Movitec VT/ Ø64 Movitec VST 8 Tri-clamp 215 4x Ø14 13 Size: DN Ø165 2 Ø64 F2 G 3/8 P Movitec VF/ Movitec VSF Size: DN 5 Ø125 Ø Ø165 4x Ø19 DN 5 DN 5 8 4x Ø Movitec VCF Size: DN 5 Ø125 Ø1 4x Ø19 DN 5 DN x Ø Dimensions V 15 E1 E2 P 3) ] Oval flange/ Tri-clamp/ Victaulic F1 F2 F1 F2 Stages ) Dimensions relevant for motors > 5.5 kw Movitec B 49

50 Movitec B, V 25, n = 145 rpm E2 E1 Movitec VF/ Movitec VSF Size: DN 65 Ø185 Ø145 Ø121 8xØ19 15 DN xØ ID3351 Ø185 Ø145 Ø121 Movitec VCF Size: DN 65 8xØ19 15 DN 65 DN xØ14 17 F ID3346 G 3/8 F Motor flange version with tapped holes Dimensions Motor flange version with tapped holes V 25 E1 E2 P 31) Stages F1 F2 31) Dimensions relevant for motors > 5.5 kw 5 Movitec B

51 Movitec B, V 25, n = 29 rpm E2 E1 E2 E1 Movitec VF/ Movitec VSF Size: DN 65 Ø185 Ø145 Ø121 8xØ19 15 DN xØ ID3351 Ø185 Ø145 Ø121 F1 G 3/8 F1 Movitec VCF Size: DN 65 8xØ19 15 DN 65 DN 65 F2 P xØ ID3346 F2 G 3/ Motor flange version with tapped holes Motor flange version with throughholes Dimensions Motor flange version with tapped holes V 25 E1 E2 P Stages Dimensions Motor flange version with throughholes V 25 E1 E2 P Stages F1 F1 F2 F2 Movitec B 51

52 Movitec B, VCF 9, V(S)F 9 E2 E1 Movitec VCF PN 16 Ø23 Ø18 Ø158 8x Ø19 14 PN Ø254 Ø19 Movitec VCF PN 25/4 Ø158 8x Ø22 14 F1 F2 G 3/8 Movitec VF/ Movitec VSF PN 16 PN 25/ Ø23 Ø18 Ø158 8x Ø19 14 DN 1 DN 1 PN Ø254 Ø Movitec VF/ Movitec VSF PN 25/4 Ø158 8x Ø22 14 PN 25/ Dimensions Movitec VCF 9, V(S)F 9, 29 rpm VCF 9, V(S)F 9 E1 E2 F1 F2 Stages VCF 9, V(S)F 9 E1 E2 F1 F2 Stages Dimensions Movitec VCF 9, V(S)F 9, 145 rpm VCF 9, V(S)F 9 E1 E2 F1 F2 Stages Movitec B

53 Movitec B, VCF 9, V(S)F 9, without motor Ø23 Ø18 * Movitec VCF PN 16 Ø158 8x Ø19 14 PN 16 G 3/ Ø254 Ø19 Movitec VCF PN 25/4 Ø158 8x Ø22 14 F1 F2 PN 25/ Ø23 Ø18 Movitec VF/ Movitec VSF PN 16 Ø158 8x Ø19 14 PN Ø254 Ø19 DN 1 DN 1 Movitec VF/ Movitec VSF PN 25/4 Ø158 8x Ø22 14 PN 25/ * Optional: thrust bearing housing Dimensions Movitec VCF 9, without motor, 29 rpm VCF 9 With bearing housing Without bearing housing F1 Stages [kg] [kg] F2 VCF 9 With bearing housing Without bearing housing F1 Stages [kg] [kg] F2 Dimensions Movitec V(S)F 9, without motor, 29 rpm V(S)F 9 With bearing housing Without bearing housing F1 Stages [kg] [kg] F2 Movitec B 53

54 V(S)F 9 With bearing housing Without bearing housing F1 Stages [kg] [kg] F2 Movitec B, VME 2, 4, 6, VE 1 E1 E2 Movitec VME external thread (V 2, 4, 6) size: G 1 ½ x Ø13 G 1 1 / G 1 / 4 G 1 1 / F1 Movitec VE external thread (V 1) Size: G x Ø13 G 2 G G 3/8 Movitec VME 2 VME 2 Stages E1 E2 F Movitec VME 4 VME 4 Stages E1 E2 F Movitec VE 1 VE 1 Stages E1 E2 F Movitec VME 6 VME 6 Stages E1 E2 F Movitec B

55 Notes on installation Standard: Vertical installation ( Page 43) Optional: Horizontal installation (possible for motor ratings up to and including 7.5 kw in systems where the installation conditions do not allow vertical installation) Movitec 2B, 4B, 6B a) b) c) H B 5 D C H 5 D C H 5 D C a) Pump bracket b) kw c) kw Installation dimensions of pump bracket as a function of motor rating and line connection ( Page 5) Motor rating [kw] B C D H [kg] Mat. No. -, E, T, V F,37/,55 kw (2-pole) 1 1 F ,75/1,1 kw (2-pole) 1 1 F ,5/2,2 kw (2-pole) 1 1 F ,/4, kw (2-pole) 1 1 F ,5/7,5 kw (2-pole) 1 21 F Movitec 1B, 15B a) b) c) B H H 5 D C 5 D C a) Pump bracket b) kw c) kw Movitec B 55

56 Installation dimensions of pump bracket as a function of motor rating and line connection ( Page 5) Motor rating [kw],75/1,1 kw (2-pole),55/,75 kw (4-pole) 1,5/2,2 kw (2-pole) 1,1/1,52 kw (4-pole) 3,/4, kw (4-pole) B C D H [kg] Mat. No. -, E, F, T, V 1B F, T, V 15B -, E 15B F ,5 121, F ,5 121, F ,5 121, ,2/4, kw (4-pole) 5,5/7,5 kw (2; 4-pole) F ,5 121, Movitec 25B a) b) c) B H H 5 D C 5 D C a) Pump bracket b) kw c) kw Installation dimensions of pump bracket as a function of motor rating and line connection ( Page 5) Motor rating [kw] B C D H [kg] Mat. No. 1,5/2,5 kw (2-pole) F , ,/4, kw (2-pole) F , ,5/7,5 kw (2-pole) F , Movitec 9B a) b) c) H H B 4 D C M8 (4x) 4 D C M8 (4x) a) Pump bracket b) kw Installation dimensions of pump bracket as a function of motor rating and line connection ( Page 5) Motor rating [kw] B C D H [kg] Mat. No. -, E, F, T, V 1B F, T, V 15B -, E 15B 5,5/7,5 kw (2; 4-pole) F Scope of supply Depending on the model, the following items are included in the scope of supply: Pump Electric motor ccessories Possible accessories: Frequency inverter, see type series booklet PumpDrive (47.5) 56 Movitec B

57 General assembly drawing with list of components Movitec V 2 B, 4 B, 6 B General assembly drawing Movitec V 2, 4, 6 List of components Part No. Description Part No. Description 1-6 Pump shroud 56 Stud 11 Pump casing 681 Coupling guard 18 Stage casing 723 Flange 16 Cover 8 Motor 21 Shaft 862 Coupling 23 Impeller 89 Baseplate Movitec B 57

High-pressure In-line Pump. Movitec B. 60 Hz. Type Series Booklet

High-pressure In-line Pump. Movitec B. 60 Hz. Type Series Booklet High-pressure In-line Pump Movitec B 6 Hz Type Series Booklet Legal information/copyright Type Series Booklet Movitec B ll rights reserved. The contents provided herein must neither be distributed, copied,

More information

Movitec VCI Type Series Booklet

Movitec VCI Type Series Booklet Multistage High-pressure Immersion Centrifugal Pump Movitec VCI Type Series Booklet Legal information/copyright Type Series Booklet Movitec VCI All rights reserved. The contents provided herein must neither

More information

High-pressure In-line Pumps 60 Hz

High-pressure In-line Pumps 60 Hz Type Series Booklet Entwurf 30.8.04 1798.56-10 High-pressure In-line Pumps 60 Hz VE V LHS Fields of Application VE are employed for general water supply, sprinkling, irrigation and pressure boosting duties,

More information

High-pressure In-line Pump. Movitec. 50 Hz. Type Series

High-pressure In-line Pump. Movitec. 50 Hz. Type Series High-pressure In-line Pump 50 Hz Type Series Operating data A Characteristic Value low rate Q [m 3 /h] 8,6 Q [l/s] 2,4 Head H [m] 1 luid temperature T [ C] -15 to +120 Operating pressure p [bar] 1) B Characteristic

More information

High-pressure In-line Pumps with and without Speed Control 50 Hz

High-pressure In-line Pumps with and without Speed Control 50 Hz Type Series Booklet 1798.5/3-10 Movitec/Movitec PumpDrive High-pressure In-line Pumps with and without Speed Control 50 Hz Movitec VE Movitec V(S) Movitec LHS Movitec V PD Fields of Application Movitec

More information

Automated Globe Valves. BOA-H Mat P PN 16/25 DN Type Series Booklet

Automated Globe Valves. BOA-H Mat P PN 16/25 DN Type Series Booklet Automated Globe Valves BOA-H Mat P PN 16/25 DN 20-150 Type Series Booklet Legal information/copyright Type Series Booklet BOA-H Mat P All rights reserved. The contents provided herein must neither be distributed,

More information

Submersible Borehole Pump. UPAchrom. 4", UPAchrom 100 CC + DN 100. Type Series Booklet

Submersible Borehole Pump. UPAchrom. 4, UPAchrom 100 CC + DN 100. Type Series Booklet Submersible Borehole Pump UPAchrom 4", UPAchrom 1 CC + DN 1 Type Series Booklet Legal information/copyright Type Series Booklet UPAchrom All rights reserved. The contents provided herein must neither be

More information

Etaprime B Type Series Booklet

Etaprime B Type Series Booklet Self-priming Pump Etaprime B Type Series Booklet Legal information/copyright Type Series Booklet Etaprime B All rights reserved. The contents provided herein must neither be distributed, copied, reproduced,

More information

Etaline MN. In-line Pumps

Etaline MN. In-line Pumps Type Series Booklet 1146.51/05--EN Etaline In-line Pumps Automation products available: Hyamaster hyatronic Fields of Application F Heating systems F Air-conditioning systems F Cooling circuits F Service

More information

Strainer BOA-S PN 6/16/25 DN Type Series Booklet

Strainer BOA-S PN 6/16/25 DN Type Series Booklet Strainer PN 6/16/25 DN 15-400 Type Series Booklet Legal information/copyright Type Series Booklet All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited

More information

Technical Data 50Hz/60Hz DIN/IEC. Vertical centrifugal immersible pumps series: DPVCI Design Version B

Technical Data 50Hz/60Hz DIN/IEC. Vertical centrifugal immersible pumps series: DPVCI Design Version B Technical Data 50Hz/60Hz DIN/IEC Vertical centrifugal immersible pumps series: DPVCI 2-4 - 6-10 - 15 Design Version B 2 Table of Contents 1 Pump introduction 1.1 General... 5 1.2 Model key... 5 1.3 Operation...

More information

Closed-coupled Pump. Etachrom B. 50 Hz - 60 Hz. Type Series Booklet

Closed-coupled Pump. Etachrom B. 50 Hz - 60 Hz. Type Series Booklet Closed-coupled Pump Etachrom B 50 Hz - 60 Hz Type Series Booklet Legal information/copyright Type Series Booklet Etachrom B All rights reserved. The contents provided herein must neither be distributed,

More information

Self-priming Pump. Etaprime B. Type Series Booklet

Self-priming Pump. Etaprime B. Type Series Booklet Self-priming Pump Etaprime B Type Series Booklet Legal information/copyright Type Series Booklet Etaprime B All rights reserved. The contents provided herein must neither be distributed, copied, reproduced,

More information

Non-return Valve BOA-R. PN 6/16 DN Flanged. Type Series Booklet

Non-return Valve BOA-R. PN 6/16 DN Flanged. Type Series Booklet Non-return Valve BOA-R PN 6/16 DN 15-350 Flanged Type Series Booklet Legal information/copyright Type Series Booklet BOA-R KSB Aktiengesellschaft Pegnitz All rights reserved. Contents provided herein must

More information

Submersible Borehole Pump. UPAchrom. 4", UPAchrom 100 CC + DN 100. Type Series Booklet

Submersible Borehole Pump. UPAchrom. 4, UPAchrom 100 CC + DN 100. Type Series Booklet Submersible Borehole Pump UPAchrom 4", UPAchrom 1 CC + DN 1 Type Series Booklet Legal information/copyright Type Series Booklet UPAchrom All rights reserved. The contents provided herein must neither be

More information

BOA-Compact. Type Series Booklet

BOA-Compact. Type Series Booklet Globe Valve BOA-Compact PN 6/16 DN 15-200 Soft-seated Flanged Type Series Booklet Legal information/copyright Type Series Booklet BOA-Compact KSB Aktiengesellschaft Pegnitz All rights reserved. Contents

More information

Hygienic Pump. Vitachrom. Type Series Booklet

Hygienic Pump. Vitachrom. Type Series Booklet Vitachrom Type Series Booklet Legal information/copyright Type Series Booklet Vitachrom All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited or processed

More information

BOA-Compact EKB. Type Series Booklet

BOA-Compact EKB. Type Series Booklet Globe Valve BOA-Compact EKB PN 10/16 DN 15-200 Soft-seated Flanged Type Series Booklet Legal information/copyright Type Series Booklet BOA-Compact EKB KSB Aktiengesellschaft Pegnitz All rights reserved.

More information

Etanorm SYT Type Series Booklet

Etanorm SYT Type Series Booklet Thermal Oil / Hot Water Pump Etanorm SYT Type Series Booklet Legal information/copyright Type Series Booklet Etanorm SYT All rights reserved. The contents provided herein must neither be distributed, copied,

More information

Technical Data 50 Hz DIN/IEC. Vertical centrifugal pumps series: DPV 2, DPV 4, DPV 6, DPV 10, DPV 15, DPV 85 Design Version B

Technical Data 50 Hz DIN/IEC. Vertical centrifugal pumps series: DPV 2, DPV 4, DPV 6, DPV 10, DPV 15, DPV 85 Design Version B Technical Data 50 Hz DIN/IEC Vertical centrifugal pumps series: DPV 2, DPV 4, DPV 6, DPV 10, DPV 15, DPV 85 Design Version B 2 Table of Contents 1 Pump introduction 1.1 General... 5 1.2 Model key... 5

More information

BOA-SuperCompact. Type Series Booklet

BOA-SuperCompact. Type Series Booklet Globe Valve BOA-SuperCompact PN 6/10/16 DN 20-200 Soft-seated Alignment Lugs Type Series Booklet Legal information/copyright Type Series Booklet BOA-SuperCompact KSB Aktiengesellschaft Pegnitz All rights

More information

Standardised Water Pump. Etanorm. Type Series Booklet

Standardised Water Pump. Etanorm. Type Series Booklet Standardised Water Pump Etanorm Type Series Booklet Legal information/copyright Type Series Booklet Etanorm All rights reserved. The contents provided herein must neither be distributed, copied, reproduced,

More information

Technical Data 60 Hz DIN/IEC Vertical centrifugal pumps series: DPV2 DPV4 DPV6 DPV85 Design Version B

Technical Data 60 Hz DIN/IEC Vertical centrifugal pumps series: DPV2 DPV4 DPV6 DPV85 Design Version B Technical Data 60 Hz DIN/IEC Vertical centrifugal pumps series: DPV2 DPV4 DPV6 DPV85 Design Version B 2 Table of Contents 1 Pump introduction 1.1 General... 4 1.2 Model key... 4 1.3 Operation... 5 1.4

More information

BOA-H Mat E Type Series Booklet

BOA-H Mat E Type Series Booklet Automated Globe Valves PN 6/5 DN 0-50 Type Series Booklet Legal information/copyright Type Series Booklet All rights reserved. The contents provided herein must neither be distributed, copied, reproduced,

More information

Double Mechanical Seals

Double Mechanical Seals Double Mechanical Seals Back-to-back Arrangement With Seal Supply System Supplementary Operating Manual Legal information/copyright Supplementary Operating Manual Double Mechanical Seals Original operating

More information

Heat Transfer Fluid / Hot Water Pump HPK-L. Type Series Booklet

Heat Transfer Fluid / Hot Water Pump HPK-L. Type Series Booklet Heat Transfer Fluid / Hot Water Pump HPK-L Type Series Booklet Legal information/copyright Type Series Booklet HPK-L All rights reserved. The contents provided herein must neither be distributed, copied,

More information

'I\ "' '""---r \ ' I\ ' ::: r-- SB, SBI, SBN Series Performance range 60 Hz. H[m] Q[m7h] SB(I/N) 60 Hz

'I\ ' '---r \ ' I\ ' ::: r-- SB, SBI, SBN Series Performance range 60 Hz. H[m] Q[m7h] SB(I/N) 60 Hz SB, SB, SB Series Performance range 6 Hz H[m] 4 3 2 1 8 6 4 3 2 '\ "' 5B1 5B1 SB1 '""r.::: r \ ' \ ' '\ '\ \: r 5B3 5B3 SB3 '\ 5B5 5B5 SB5 5B1 5B1 SB1 5B15 5B15 SB15 \ ' 5B112, 5B2 5B45 5B9 5B2 5B45 5B9

More information

Technical Data 50 Hz. Vertical centrifugal pumps Series: DPVE / DPV(S) / DPVCF / DPLHS

Technical Data 50 Hz. Vertical centrifugal pumps Series: DPVE / DPV(S) / DPVCF / DPLHS Technical Data 50 Hz Vertical centrifugal pumps Series: DPVE / DPV(S) / DPVCF / DPLHS DPVE DPV(S) DPVCF DPLHS Table of Contents 1 Pump introduction 1.1 General... 5 1.2 Model key... 5 1.3 Description of

More information

BOA-Control IMS. Type Series Booklet

BOA-Control IMS. Type Series Booklet Balancing and Shut-off Valve BOA-Control IMS PN 16 DN 15-350 Flow Rate and Temperature Sensor Flanged Ends Type Series Booklet Legal information/copyright Type Series Booklet BOA-Control IMS All rights

More information

High-Pressure Multistage Centrifugal Pumps Single-head pumps

High-Pressure Multistage Centrifugal Pumps Single-head pumps Series overview Wilo-Economy MHI, Economy MHIL, Multivert MVIS Series: Wilo-Economy MHI H[m] 6 5 4 3 Wilo-Economy-MHI 5 Hz >Non self-priming pump for: Water supply and pressure boosting Commerce and industry

More information

VM, VMC, VMN. Vertical Multistage Centrifugal Pump, 60Hz

VM, VMC, VMN. Vertical Multistage Centrifugal Pump, 60Hz VM, VMC, VMN Vertical Multistage Centrifugal Pump, 60Hz Approvals CERTIFICATE IQNet and SQS hereby certify that the organisation Swiss Pump Company AG 3645 Thun-Gwatt Switzerland Whole Company Design,

More information

Globe Valve BOA-H. PN 16/25 DN Bellows Flanged. Type Series Booklet

Globe Valve BOA-H. PN 16/25 DN Bellows Flanged. Type Series Booklet Globe Valve BOA-H PN 16/25 DN 15-350 Bellows Flanged Type Series Booklet Legal information/copyright Type Series Booklet BOA-H KSB Aktiengesellschaft All rights reserved. The s provided herein must neither

More information

Technical data 50 & 60 Hz. Vertical centrifugal pumps Series: DPLHS

Technical data 50 & 60 Hz. Vertical centrifugal pumps Series: DPLHS Technical data 50 & 60 Hz Vertical centrifugal pumps Series: DPLHS 2 Table of Contents 1 Pump introduction 1.1 General... 4 1.2 Model key... 4 1.3 Description of the product... 4 1.4 Operation... 5 1.5

More information

Waste Water, Condensate and Heat Transfer Fluid Pump. Type Series Booklet

Waste Water, Condensate and Heat Transfer Fluid Pump. Type Series Booklet Waste Water, Condensate and Heat Transfer Fluid Pump Type Series Booklet Legal information/copyright Type Series Booklet All rights reserved. The contents provided herein must neither be distributed, copied,

More information

VERTICAL MULTISTAGE PUMPS HIL AND HILFLEX SEE OUR FLEXDRIVE LEAFLET FOR DRIVE DETAILS. reliable efficient quality. Pumping Technology

VERTICAL MULTISTAGE PUMPS HIL AND HILFLEX SEE OUR FLEXDRIVE LEAFLET FOR DRIVE DETAILS. reliable efficient quality. Pumping Technology TM VERTICAL MULTISTAGE PUMPS HIL AND HILFLEX SEE OUR FLEXDRIVE LEAFLET FOR DRIVE DETAILS reliable efficient quality HIL Vertical Multistage Pumps Introduction Smedegaards' range of HIL vertical multistage

More information

franklinwater.com.au 50 Hz VR SERIES Vertical Multi-Stage Pumps 1 thru 10 m 3 h

franklinwater.com.au 50 Hz VR SERIES Vertical Multi-Stage Pumps 1 thru 10 m 3 h franklinwater.com.au 5 Hz VR SERIES Vertical Multi-Stage Pumps 1 thru 1 m 3 h ii 5 HZ VR SERIES VERTICAL MULTI-STAGE PUMPS Features... 2 Applications... 2 Counter-Flange Kits... 3 Pump Specifications...

More information

Etanorm GPV-D/CPV-D Etanorm GPV-W/CPV-W

Etanorm GPV-D/CPV-D Etanorm GPV-W/CPV-W Type series booklet 1214.5/04-EN Vertical Low-Pressure Centrifugal Pumps (D) Dry Bearing - Cantilever Design (W) Wet Bearing - Plain Bearing Fields of Application Etanorm GPV/CPV pumps are used for handling

More information

Boiler Feed Booster Pump YNK. Type Series Booklet

Boiler Feed Booster Pump YNK. Type Series Booklet YNK Type Series Booklet Legal information/copyright Type Series Booklet YNK All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited or processed for any

More information

Hygienic Pump. Vitacast Bloc. Type Series Booklet

Hygienic Pump. Vitacast Bloc. Type Series Booklet Vitacast Bloc Type Series Booklet Legal information/copyright Type Series Booklet Vitacast Bloc All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited

More information

e-sv Series 1, 3, 5, 10, 15, 22, 33, 46, 66, 92, 125

e-sv Series 1, 3, 5, 10, 15, 22, 33, 46, 66, 92, 125 e-sv Series 1, 3, 5, 1, 15, 22, 33, 46, 66, 92, 125 Vertical Multistage Electric Pumps equipped with high efficiency motors 5 Hz 2 e-sv SERIES HYDRAULIC PERFORMANCE RANGE AT 5 Hz 3 4 5 6 8 1 2 3 4 5 6

More information

The e-nsc End Suction Pump Series

The e-nsc End Suction Pump Series NEW The e-nsc End Suction Pump Series Your go-to single-stage pump for heavy-duty use STANDARDIZED TO EN733, ISO 5199 AND DIRECTIVE 9/125/EC. POTABLE WATER APPROVED (ACS AND DM174). It s not your standard

More information

Waste Water, Condensate and Heat Transfer Liquid Pump. Type Series Booklet

Waste Water, Condensate and Heat Transfer Liquid Pump. Type Series Booklet Waste Water, Condensate and Heat Transfer Liquid Pump MK Type Series Booklet Legal information/copyright Type Series Booklet MK All rights reserved. The contents provided herein must neither be distributed,

More information

e-sv Series 1, 3, 5, 10, 15, 22, 33, 46, 66, 92, 125

e-sv Series 1, 3, 5, 10, 15, 22, 33, 46, 66, 92, 125 e-sv Series 1, 3, 5, 10, 15, 22, 33, 46, 66, 92, 125 Vertical Multistage Electric Pumps equipped with high efficiency motors 50 Hz e-sv SERIES HYDRAULIC PERFORMANCE RANGE AT 50 Hz WEB 07-2010 2 CONTENTS

More information

SB,SBI,SBN 1,3,5,10,15,20,32,45,64,90,120,150 series

SB,SBI,SBN 1,3,5,10,15,20,32,45,64,90,120,150 series SB,SB,SBN 1,3,5,1,15,2,32,5,6,9,12,15 series l'l!..l.' General data 2 SB, SB, SBN Performance range at 6 Hz 3 Product data Product data 5 Pump, Application 6 dentification Code, 7 data, Mechanical Seal

More information

Strainers BOA -S. PN 6/16/25 DN Flanged. Type Series Booklet

Strainers BOA -S. PN 6/16/25 DN Flanged. Type Series Booklet BOA -S PN 6/16/25 DN 15-300 Flanged Type Series Booklet Legal information/copyright Type Series Booklet BOA -S KSB Aktiengesellschaft Pegnitz All rights reserved. Contents provided herein must neither

More information

Norm-Centrifugal Pumps PN 10

Norm-Centrifugal Pumps PN 10 Norm-Centrifugal Pumps PN 10 Pump dimensions acc. to DIN EN 733 with additional sizes Technical requirements acc. to DIN ISO 9908 Application For pumping pure water, industrial water, sea water, condensate,

More information

RDLO / RDLO V Type Series Booklet

RDLO / RDLO V Type Series Booklet RDL / RDL V Type Series Booklet Legal information/copyright Type Series Booklet RDL / RDL V All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited or

More information

Grey Water and Condensate Pump. Rotex. Type Series Booklet

Grey Water and Condensate Pump. Rotex. Type Series Booklet Rotex Type Series Booklet Legal information/copyright Type Series Booklet Rotex Original operating manual All rights reserved. The contents provided herein must neither be distributed, copied, reproduced,

More information

Standardised Water Pump. Etanorm. Type Series Booklet

Standardised Water Pump. Etanorm. Type Series Booklet Standardised Water Pump Etanorm Type Series Booklet Legal information/copyright Type Series Booklet Etanorm KSB Aktiengesellschaft All rights reserved. The contents provided herein must neither be distributed,

More information

RDLO / RDLO V Type Series Booklet

RDLO / RDLO V Type Series Booklet RDL / RDL V Type Series Booklet Legal information/copyright Type Series Booklet RDL / RDL V All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited or

More information

NB /193 A-F2-A-BAQE

NB /193 A-F2-A-BAQE GRUNDFOS DATA BOOKLET NB100-200/193 A-F2-A-BAQE Grundfos Pump 98305367 Thank you for your interest in our products Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/nb000/98305367/nb-100-200-193-a-f2-a-e-baqe.html

More information

Mag-drive Pump. Magnochem-Bloc. Type Series Booklet

Mag-drive Pump. Magnochem-Bloc. Type Series Booklet Mag-drive Pump Magnochem-Bloc Type Series Booklet Legal information/copyright Type Series Booklet Magnochem-Bloc All rights reserved. The contents provided herein must neither be distributed, copied, reproduced,

More information

Process Pump RPH. Type Series Booklet

Process Pump RPH. Type Series Booklet Process Pump RPH Type Series Booklet Legal information/copyright Type Series Booklet RPH All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited or processed

More information

Designation. Accessories Drive

Designation. Accessories Drive Type Series Booklet + 60 Hz 275.5/9- G2 Etaprime L Self-priming Pumps for Pure or Contaminated Fluids Fields of Application Water supply Fire-fighting systems Sprinkling Irrigation Drainage Air-conditioning

More information

e-sv Series 1, 3, 5, 10, 15, 22 33, 46, 66, 92, 125 Lenntech 50/60 Hz Tel Fax.

e-sv Series 1, 3, 5, 10, 15, 22 33, 46, 66, 92, 125 Lenntech 50/60 Hz Tel Fax. 5/6 Hz e-sv Series 1, 3, 5, 1, 15, 22 33, 46, 66, 92, 125 SPECIAL VERSIONS Lenntech info@lenntech.com Tel. +31-152-61-9 www.lenntech.com Fax. +31-152-616-289 Cod. 191241 Rev ev.d Ed.6/212 CONTENTS INTRODUCTION

More information

ILN, ILNC. In Line vertical pumps. ILN single suction ILN double suction ILNC. 1. Fields of Application. 3. Design. 4. Designation. 2.

ILN, ILNC. In Line vertical pumps. ILN single suction ILN double suction ILNC. 1. Fields of Application. 3. Design. 4. Designation. 2. Type series booklet CTI-2600/04 [04-2017] ILN, ILNC In Line vertical pumps ILN single suction ILN double suction ILNC sizes 65/ to 250/... sizes 300/ all sizes 1. Fields of Application Suitable for a wide

More information

Close-coupled pumps Series ES04

Close-coupled pumps Series ES04 Close-coupled pumps Series ES04 www.andritz.com/pumps General Description / Application Pumps of series ES04 are extremely compact units which require very little space. They are particularly suitable

More information

SV Series SV 2, 4, 8, 16 SV 33, 46, 66, 92

SV Series SV 2, 4, 8, 16 SV 33, 46, 66, 92 SV Series SV 2, 4, 8, 16 SV 33, 46, 66, 92 Vertical Multistage Electric Pumps equipped with high efficiency PLM motors 60 Hz SV SERIES HYDRAULIC PERFORMANCE RANGE AT 60 Hz WEB 04-2008 2 CONTENTS Specifications...5

More information

Data sheet. Page: 1 / 5. ETL GGSAV11D BKSBIE3 Inline pump. Operating data. Design

Data sheet. Page: 1 / 5. ETL GGSAV11D BKSBIE3 Inline pump. Operating data. Design Data sheet Page: 1 / 5 Operating data Requested flow rate Operating data determined for maximum inlet pressure Requested developed head 15.00 m Pumped medium Ambient air temperature 20.0 C Fluid temperature

More information

Control Valve BOA-CVE H PN 16/25 DN Type Series Booklet

Control Valve BOA-CVE H PN 16/25 DN Type Series Booklet Control Valve BOA-CVE H PN 16/25 DN 20-150 Type Series Booklet Legal information/copyright Type Series Booklet BOA-CVE H All rights reserved. The contents provided herein must neither be distributed, copied,

More information

PVM/PVMI/PVMX VERTICAL MULTISTAGE CENTRIFUGAL PUMPS

PVM/PVMI/PVMX VERTICAL MULTISTAGE CENTRIFUGAL PUMPS PVM/PVMI/PVMX High hydraulic efficiency, Motor designed according to EN regulations IE3 MOTOR PVM, PVMI and PVMX are non selfpriming vertical multi-stage pumps, with Victaulic or flanged fittings with

More information

High-efficiency Drinking Water Pump. Rio-Eco Therm N. Type Series Booklet

High-efficiency Drinking Water Pump. Rio-Eco Therm N. Type Series Booklet High-efficiency Drinking Water Pump Rio-Eco Therm N Type Series Booklet Legal information/copyright Type Series Booklet Rio-Eco Therm N All rights reserved. The contents provided herein must neither be

More information

BOAX-B Mat E. Type Series Booklet

BOAX-B Mat E. Type Series Booklet Butterfly Valve with Electric Actuator BOAX-B Mat E PS 16 bar: DN 40 to 200 PS 10 bar: DN 250 and 300 Design to EN 593 and ISO 10631 Type Series Booklet Legal information/copyright Type Series Booklet

More information

Lowara. Centrifugal Electric Pumps Manufactured in AISI 316 Stainless Steel in Compliance with EN 733. SH Series. 60 Hz

Lowara. Centrifugal Electric Pumps Manufactured in AISI 316 Stainless Steel in Compliance with EN 733. SH Series. 60 Hz Centrifugal Electric Pumps Manufactured in AISI 316 Stainless Steel in Compliance with EN 733 SH Series 60 Hz SERIE SH HYDRAULIC PERFORMANCE RANGE AT 60 Hz WEB 10-2006 2 CONTENTS 5 Specifications... 6

More information

CONDA-VRC Type Series Booklet

CONDA-VRC Type Series Booklet Pressure Reducing Valve PN 16/25/40/63 DN 15-150 Type Series Booklet Legal information/copyright Type Series Booklet All rights reserved. The contents provided herein must neither be distributed, copied,

More information

TP /4-A-F-A-BUBE 400Y 50HZ

TP /4-A-F-A-BUBE 400Y 50HZ GRUNDFOS DATA BOOKLET TP 1-6/4-A-F-A-BUBE 4Y 5HZ Grundfos Pump 9642628 Thank you for your interest in our products Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/tp/9642628/tp-1-6-4-a-f-a-bube.html

More information

Lenntech. Calio S. Type Series Booklet. High-efficiency Circulator Pump. Tel Fax.

Lenntech. Calio S. Type Series Booklet. High-efficiency Circulator Pump. Tel Fax. Lenntech info@lenntech.com Tel. +--6-9 www.lenntech.com Fax. +--66-89 High-efficiency Circulator Pump Type Series Booklet Legal information/copyright Type Series Booklet All rights reserved. The contents

More information

Lowara. Centrifugal electric pumps made of AISI 316 stainless steel in compliance with EN 733. SH Series. 50 Hz

Lowara. Centrifugal electric pumps made of AISI 316 stainless steel in compliance with EN 733. SH Series. 50 Hz Centrifugal electric pumps made of AISI 316 stainless steel in compliance with EN 733 SH Series 50 Hz SERIE SH OPERATING CHARACTERISTICS AT 50 Hz PRINT 05-2007 2 CONTENTS 5 Specifications......................................................................

More information

Multistage Pumps MP, MPA, MPB, MPV SIZES DN 40 - DN 125. Jansen Pompentechniek T: +31(0) E:

Multistage Pumps MP, MPA, MPB, MPV SIZES DN 40 - DN 125. Jansen Pompentechniek T: +31(0) E: Multistage Pumps MP, MPA, MPB, MPV SIZES DN 40 - DN 125 Technical Data Performance range: m Capacities up to 340m 3 /h (1500USgpm) m Head up to 500m (1640feet) m Max. speed up to 3600rpm Multistage pumps

More information

TP 40-30/4-A-F-A-BUBE 400Y 50HZ

TP 40-30/4-A-F-A-BUBE 400Y 50HZ GRUNDFOS DATA BOOKLET TP -30/4-A-F-A-BUBE 0Y 50HZ Grundfos Pump 961883 Thank you for your interest in our products Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/tp000/961883/tp--30-4-a-f-a-bube.html

More information

EVM. VERTICAL MULTISTAGE ELECTRIC PUMPS in cast iron, AISI 304, AISI 316. Your Life, our Quality. Worldwide. 36 Commercial

EVM. VERTICAL MULTISTAGE ELECTRIC PUMPS in cast iron, AISI 304, AISI 316. Your Life, our Quality. Worldwide. 36 Commercial Vertical multistage centrifugal electric pumps available in various versions: cast iron (G), AISI 304 stainless steel (), AISI 316 stainless steel (L). APPLICATIONS Civil, industrial, agricultural and

More information

Data sheet: Wilo-Multivert MVI 805 (3~400 V, EPDM, PN 16)

Data sheet: Wilo-Multivert MVI 805 (3~400 V, EPDM, PN 16) Data sheet: Wilo-Multivert MVI 8 (~ V, EPDM, PN ) Pump curves 89 8 Wilo-Multivert-MVI 8-89 Hz Power Fluid temperature T -...+ C NPSH [m] H[m] 8 8 8 8 88 8 8 8 8 8 8 8 8 η p NPSH 8 8 [l/s] 89 η p [%] Max.

More information

NK /310A2F1AE-SBAQE

NK /310A2F1AE-SBAQE GRUNDFOS DATA BOOKLET NK15-315/31A2F1AE-SBAQE Grundfos Pump 98318632 Thank you for your interest in our products Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/nkbasis/98318632/nk-15-315-31-a2-f-a-e-baqe.html

More information

franklinwater.com 50 Hz VR SERIES Vertical Multi-Stage Pumps

franklinwater.com 50 Hz VR SERIES Vertical Multi-Stage Pumps franklinwater.com 5 Hz VR SERIES Vertical Multi-Stage Pumps 5 HZ VR SERIES VERTICAL MULTI-STAGE PUMPS Features 2 Applications 2 Pump Specifications Counter-Flange Kits Motor Specifications 4 Ordering

More information

MAMMOUTH Type Series Booklet

MAMMOUTH Type Series Booklet Butterfly Valve MAMMOUTH DN 1050-4000 PS 25 bar Type Series Booklet Legal information/copyright Type Series Booklet MAMMOUTH All rights reserved. The contents provided herein must neither be distributed,

More information

TP /2-A-F-A-BAQE 400D 50HZ

TP /2-A-F-A-BAQE 400D 50HZ GRUNDFOS DATA BOOKLET TP 32-38/2-A-F-A-BAQE 4D 5HZ Grundfos Pump 968677 Thank you for your interest in our products Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/tp/968677/tp-32-38-2-a-f-a-baqe.html

More information

ECOLINE GTC Type Series Booklet

ECOLINE GTC Type Series Booklet Gate Valve ECOLINE GTC 150-600 Class 150-600 NPS 2''-36'' Cast Steel / Stainless Steel Bolted Bonnet Flanged Ends Type Series Booklet Legal information/copyright Type Series Booklet ECOLINE GTC 150-600

More information

SV Series SV 2, 4, 8, 16 SV 33, 46, 66, 92

SV Series SV 2, 4, 8, 16 SV 33, 46, 66, 92 SV Series SV 2, 4, 8, 16 SV 33, 46, 66, 92 Vertical Multistage Electric Pumps equipped with high efficiency PLM motors 50 Hz SV SERIES HYDRAULIC PERFORMANCE RANGE AT 50 Hz WEB 06-2008 2 CONTENTS Specifications...5

More information

Multistage Pumps. Vogel Series P, PVa, MP 300

Multistage Pumps. Vogel Series P, PVa, MP 300 Multistage Pumps Vogel Series P, PVa, MP 300 Technical Data Performance range: m Capacities up to 1800m 3 /h (8800USgpm) m Head up to 300m (1000feet) m Max. speed up to 1750rpm Multistage pumps of series

More information

50 Hz. Z612, Z616, Z622 Z631, Z646, Z660 Series 6 SUBMERSIBLE ELECTRIC PUMPS. ErP 2009/125/EC

50 Hz. Z612, Z616, Z622 Z631, Z646, Z660 Series 6 SUBMERSIBLE ELECTRIC PUMPS. ErP 2009/125/EC 5 Hz Z612, Z616, Z622 Z631, Z646, Z66 Series 6 SUBMERSIBLE ELECTRIC PUMPS ErP 29/125/EC Cod. 1915991 Rev. D Ed.9/217 CONTENTS Hydraulic performance range...4 Series Specifications...5 Table of Materials...7

More information

TP /2-A-F-A-BUBE 1X230 50HZ

TP /2-A-F-A-BUBE 1X230 50HZ GRUNDFOS DATA BOOKLET TP 8-12/2-A-F-A-BUBE 1X23 5HZ Grundfos pump 9642448 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/tp/9642448/tp-8-12-2-a-f-a-bube.html

More information

Data sheet: Wilo-Multivert MVI 205 (3~400 V, EPDM, PN 16)

Data sheet: Wilo-Multivert MVI 205 (3~400 V, EPDM, PN 16) Data sheet: Wilo-Multivert MVI 5 (3~4 V, EPDM, PN 16) Pump curves 4 Wilo-Multivert-MVI - 5 Hz Power Fluid temperature T -15...+1 C 18 17 Max. ambient temperature T 4 C P [kw] NPSH [m] H[m] 14 16 14 1 1

More information

EVM. VERTICAL MULTISTAGE ELECTRIC PUMPS in cast iron, AISI 304, AISI 316. Your Life, our Quality. Worldwide. 36 Commercial

EVM. VERTICAL MULTISTAGE ELECTRIC PUMPS in cast iron, AISI 304, AISI 316. Your Life, our Quality. Worldwide. 36 Commercial Vertical multistage centrifugal electric pumps available in various versions: cast iron (G), AISI 304 stainless steel (), AISI 316 stainless steel (L). APPLICATIONS Civil, industrial, agricultural and

More information

TECHNICAL BROCHURE BeSV60 R8. e-sv. 60 Hz Technical Manual E-SV SERIES VERTICAL MULTI-STAGE PUMPS

TECHNICAL BROCHURE BeSV60 R8. e-sv. 60 Hz Technical Manual E-SV SERIES VERTICAL MULTI-STAGE PUMPS TECHNICAL BROCHURE BeSV6 R8 e-sv 6 Hz Technical Manual E-SV SERIES VERTICAL MULTI-STAGE PUMPS PAGE 2 Contents Coverage Curves.... 4 General Market Specifications.....................................................................................

More information

Data sheet: Wilo-Multivert MVI 404 (1~230 V, EPDM, PN 16)

Data sheet: Wilo-Multivert MVI 404 (1~230 V, EPDM, PN 16) Data sheet: Wilo-Multivert MVI (1~3 V, EPDM, PN 16) Pump curves Wilo-Multivert-MVI - 5 Hz Power Fluid temperature T -15...+1 C 18 16 Max. ambient temperature T C 1 1 Maximum operating pressure p max 16

More information

SVI SERIES HYDRAULIC PERFORMANCE RANGE AT 50 Hz

SVI SERIES HYDRAULIC PERFORMANCE RANGE AT 50 Hz 50 Hz SVI Series 2, 4, 8, 16, 33, 46, 66, 92 SUBMERSIBLE VERTICAL ELECTRIC PUMPS EQUIPPED WITH IE2 MOTORS COMPLYING WITH REGULATION (EC) no. 640/2009 Cod. 191002451 Rev ev.a.a Ed.01/2012 SVI SERIES HYDRAULIC

More information

NK40-160/172A1F2AE-SBAQE

NK40-160/172A1F2AE-SBAQE GRUNDFOS DATA BOOKLET NK4-16/172A1F2AE-SBAQE Grundfos pump 9782923 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/nkbasis/9782923/nk-4-16-172-a1-f-a-e-baqe.html

More information

Lenntech. Calio-Therm S. Type Series Booklet. High-efficiency Drinking Water Pump

Lenntech. Calio-Therm S. Type Series Booklet. High-efficiency Drinking Water Pump Lenntech info@lenntech.com Tel. +--6-9 www.lenntech.com Fax. +--66-89 High-efficiency Drinking Water Pump Calio-Therm S Type Series Booklet Legal information/copyright Type Series Booklet Calio-Therm S

More information

Stainless Steel Vertical Multistage Pump CONTENTS

Stainless Steel Vertical Multistage Pump CONTENTS , EVMUG/L - V ertic ca l Multistage s D ata Book 6Hz / EVMU(G)(L) CONTENTS SECTION PAGE FEATURES 2 TYPICAL APPLICATIONS 3 MODEL DESIGNATION 4 PRODUCT SPECIFICATIONS 1 2 5 EVMU(G)(L)32 - EVMU(G)(L)64 6

More information

A Series 50HZ. A - Series. Vertical Multistage Centrifugal in-line Pumps AVC/AVI/AVS ISO-9001

A Series 50HZ. A - Series. Vertical Multistage Centrifugal in-line Pumps AVC/AVI/AVS ISO-9001 A - Series A Series ISO-9 AVC/AVI/AVS HZ Evak Pump Technology Corp. No., Zhongshan Rd., Qingshui Township, Taichung County, Taiwan. Tel : +-- Fax: +--9 www.evak-pumps.com Vol. PIAV- A-Series Index Multistage

More information

NB /263 AS-F2-A-BAQE

NB /263 AS-F2-A-BAQE GRUNDFOS DATA BOOKLET NB125-25/263 AS-F2-A-BAQE Grundfos pump 9832195 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/nb/9832195/nb-125-25-263-as-f2-a-e-baqe.html

More information

SICCA SCC Type Series Booklet

SICCA SCC Type Series Booklet Swing Check Valve SICCA 150-600 SCC Class 150-600 NPS 2-24 Inches Type Series Booklet Legal information/copyright Type Series Booklet SICCA 150-600 SCC All rights reserved. The contents provided herein

More information

Pressure boosting Single pumps

Pressure boosting Single pumps Series description Wilo-Economy MHI Design Non-self-priming multistage pump Application Water supply and Commerce and industry Cooling water circulation systems Washing and sprinkling systems Type key

More information

CONDA-VLC Type Series Booklet

CONDA-VLC Type Series Booklet Level Control Valve PN 16 DN 25-300 Type Series Booklet Legal information/copyright Type Series Booklet All rights reserved. The contents provided herein must neither be distributed, copied, reproduced,

More information

BOA-CVE H. Type Series Booklet

BOA-CVE H. Type Series Booklet Control Valve BOA-CVE H PN 16/25 DN 20-150 Type Series Booklet Legal information/copyright Type Series Booklet BOA-CVE H KSB Aktiengesellschaft Pegnitz All rights reserved. Contents provided herein must

More information

TP /4-A-F-A-BQQE 400Y 50HZ

TP /4-A-F-A-BQQE 400Y 50HZ GRUNDFOS DATA BOOKLET TP 4-1/4-A-F-A-BQQE 4Y 5HZ Grundfos Pump 9686883 Thank you for your interest in our products Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/tp/9686883/tp-4-1-4-a-f-a-bqqe.html

More information

NB /438 A-F1-A-GQQE

NB /438 A-F1-A-GQQE GRUNDFOS DATA BOOKLET NB15-4/438 A-F1-A-GQQE Grundfos pump 983626 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/nb/983626/nb-15-4-438-a-f1-a-e-gqqe.html

More information

Data sheet. Page: 1 / 5 ETN GG A 11GA201502B. Operating data. Design. Requested developed head m. Efficiency 74.

Data sheet. Page: 1 / 5 ETN GG A 11GA201502B. Operating data. Design. Requested developed head m. Efficiency 74. Data sheet Page: 1 / 5 Operating data Requested flow rate 160.00 m³/h Actual flow rate 159.85 m³/h Operating data determined for maximum inlet pressure Actual developed head 20.96 m Requested developed

More information

Circulator Pumps with Continuously Variable Differential Pressure Control and I.R. Interface for Remote Control

Circulator Pumps with Continuously Variable Differential Pressure Control and I.R. Interface for Remote Control Type series booklet 1115.52/2-10 Riotec r /Riotec r Z Circulator Pumps with Continuously Variable Differential Pressure Control and I.R. Interface for Remote Control Riotec Riotec Z Energy efficiency class

More information

INVCP, INVCN. Vertical pumps for tanks. 3. Design. 1. Fields of Application. 4. Designation. 2. Operating Data

INVCP, INVCN. Vertical pumps for tanks. 3. Design. 1. Fields of Application. 4. Designation. 2. Operating Data Type series booklet CTI-0300/03 [05-2012] INVCP, INVCN Vertical pumps for tanks 1. Fields of Application INVCP pumps are used for organic and inorganic liquids in water services and different industries.

More information