Stock Catalog HVAC Products

Size: px
Start display at page:

Download "Stock Catalog HVAC Products"

Transcription

1 Stock Catalog HVAC Products 57 Ash Circle Warminster, PA (215) Ph / (215) Fax

2 Representing and Distributing AbsolutAire, Inc. Acudor Products Broan Cerus Industrial Dynasonics, Inc. Elgen Fabric Air Fantech Direct and Indirect Make-Up Air and Handling Equipment Access Doors, Floor Hatches, Roof Hatches & Smoke Vents Ventilating Fans, Heaters & Combination Units and Hoods Starters, Disconnects & VFD's Sound Control Products, Silencers, Acoustical Louvers, Fan Housings, Acoustic Panels Flex Duct Connectors, Corners, Cleats, Vanes, Rails, Damper Hardware, Access Doors Fabric Duct Inline Duct Fans, Dryer Booster Fans & Axial Fans HEPA / ULPA, Fan Powered Filters, Gas Turbine Filters, Housings, UV Lights Filtration Group Isloation Room Containment Systems Grills, Registers & Diffusers, Terminal Units, Displacement Ventilation, Underfloor Krueger Air Distribution. Chilled Beams Round Spiral Duct (Single & Double), Flat Oval (Single & Double), Fittings Lindab Lloyd Industries Stainless Steel (Single & Double), PVC Spiral, Sound Attenuators Roof Curbs, Equipment Rails, Fire & Smoke Dampers, Dampers & Louvers Roof Exhausters, Blowers, Ceiling Fans, Inline Fans, Prop Fans, Make-Up Loren Cook Mars Sales Co. Panasonic Pate Company Pottorff Company Powered Aire Inc. Prefco Products Q-Mark Air Fans, Energy Recovery Units, Gravity Vents, Material Handling Fans Electric, Hot Water & Gas Air Curtains Ultra Quiet Bathroom Ventialtion Roof Curbs, Equipment Supports, Pipe Portals Louvers, Fire & Smoke Dampers, Control Dampers, Volume Dampers Air Doors - Direct Fired, Indirect Fired, Electrically Heated, Untempered Fire Dampers, Smoke Dampers, Combination Dampers, Backdraft Dampers Electric Baseboard, Wall & Unit Heaters Static Plate Core Energy Recovery Ventilators, Dedicated Outside Air Systems, RenewAire Select Air Systems Sunvent Industries TAMCO Thermoflex/Flexvent Ultra Quiet Energy Star Bathroom Exhaust Fans Custom Kitchen Ventilation Systems Brick Vents Thermally Insulated, Salt Water Resistant, Airfoil Control, and Multizone Dampers Flexible Duct

3 EST Table of Contents Access Doors Airtite Duct Take-Offs Bellmouth Airtite Duct Take-Offs Brick Vents Caps - Roof... 25,29,34 Caps - Wall... 25,34 Collars... 11,12 Contact List... Back Cover Dampers - Low Velocity Dampers - Round Duct... 11,12 Diffusers... 2,3 Directions... Back Cover Duct Straps Elbows - Adjustable Elbows - Spiral Fixed... 7 Engineering Notes... 39,40 Equipment Rails Fans - Ceiling... 21,23,32,33,34 Fans - Roof Mounted Down-Blast... 14,15 Fans - Roof Mounted Up-Blast... 16,17 Fans - Roof Mounted UL ,19 Fans - Wall Mounted Propeller... 26,27,28 Fans - Utility... 30,31 Fans - Inline... 19,20,22,23 Fittings - Spiral Duct... 7 Flex Duct... 35,36 Gravity Vents Grilles... 3,4,5 Gripple... 6 Pipe Portals Reducers... 7,10 Registers... 3,4,5,9 Roof Curbs Snap Pipe & Fittings... 10,11,12 Speed Controls... 24,34 Spiral Pipe & Fittings... 6,7,8,9 Starters Tape Tees... 7,11 Terms and Conditions Time Delay Switch... 24,34 Vibration Isolators

4 SUPPLY DIFFUSERS SH F22 / SH F21 SH F23 : Material: Steel Flat / Beveled Frame 1, 2, 3, 4 or Way Blow Pattern Optional Damper White Finish Removable Core : Material: Steel Louvered Face 4 Way Blow Pattern Optional Damper White Finish SURFACE MOUNT Model SH F22 / SH F21 Neck CFM Nominal Face 6 x x 11 9 x x x x x x x x 23 T-BAR LAY-IN Model SH F23 Neck CFM Nominal Face 6 x x 24 9 x x x x x x x x 24 SHR F23 : Material: Steel Louvered Face 4 Way Blow Pattern Optional Damper White Finish Square to Round Adapter Model SHR F23 - Round Neck Neck / Dia. CFM N. Face 6 x 6 / x 24 9 x 9 / x x 12 / x x 12 / x x 15 / x x 18 / x F23 : Material: Steel Full Louvered Face 360 Fixed Horizontal Airflow 4 Way Blow Pattern Optional Damper White Finish Model 1450 F23 Neck Dia. CFM Nominal Face x x x x x F23 : Material: Steel Hinged Perforated Face 1-,2-,3-,4 - Way Adj. Blow Optional Damper White Finish Inside & Out Model 6600 F23 Neck Dia. CFM Nominal Face x x x x x x 24 Note: CFM's listed with air devices are suggested capacities for normally configured commercial duct systems. Generally these were selections at approximately NC30. Call for en- 2

5 PLQ F23 : Material: Steel Plaque Face 360 Fixed Horizontal Airflow 4 Way Blow Pattern Optional Damper White Finish Model 1450 F23 Neck Dia. CFM Nominal Face 6" x 24 8" x 24 10" x 24 12" x 24 14" x 24 SUPPLY REGISTERS 880V OBD F22 : Material: Steel Frame and Blades Adjustable, Double Deflection, Vertical Front Blades, Horizontal Rear Blades Opposed Blade Damper Attached White Finish SURFACE MOUNT Model V4004SD-1 Size CFM Size CFM Size CFM 6 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x Note: CFM's listed with air devices are suggested capacities for normally configured commercial duct systems. Generally these were selections at approximately NC30. Call for en- 3

6 RETURN REGISTERS 6690/6490 F23 : Material: Steel Perforated Face Optional Damper White Finish, Inside & Out T-BAR LAY-IN Model 6690 F23 Neck CFM Nominal Face x x x x x x 24 Model 6490 F23 Neck CFM Nominal Face 22 x x F23 : Material: Steel Perforated Face White Finish Model 6490 F23 SIZE CFM Perf Screen 24 x Only EGC5 : Material: Aluminum 1/2 x 1/2 x 1/2 Core Includes Damper White Finish Model EGC-6 Egg Crate Neck CFM Nominal Face 22 x x x x x x 24 HCF23 : Material: Aluminum Permits T-Bar Lay-In devices to be installed in drywall or plaster ceilings and allows access to space above White Finish Model HCF23 - T-Bar Plaster Frame Size 12 x x x 24 Note: CFM's listed with air devices are suggested capacities for normally configured commercial duct systems. Generally these were selections at approximately NC30. Call for en- 4

7 RETURN REGISTERS S80H OBD F22 : Material: Steel Fixed Horizontal 45 Deflection Blade Includes Damper White Finish SURFACE MOUNT Model S80H OBD F22 Size CFM Size CFM 6 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x S80H F23 : Material: Steel Fixed Horizontal 45 Deflection Blade White Finish T-BAR LAY-IN Model S80H F23 Neck CFM Nominal Face 22 x x x x 24 S80H F23 FF : Material: Steel Fixed Horizontal 45 Deflection Blade Filter Holding Frame White Finish Model S80H F23 Filter Frame Neck CFM Nominal Face 22 x x 24 Note: CFM's listed with air devices are suggested capacities for normally configured commercial duct systems. Generally these were selections at approximately NC30. Call for en- 5

8 SPIRAL DUCT Lindab SPIROsafe features: IT S TIGHT Double lipped, double sealing gaskets. SPIROsafe out performs SMACNA's leakage class 3 from -20 in. WG to +12 in. WG. SPIROsafe is fully functional from -20 degree F to +212 degree F. Factory controlled dimensional tolerances to %. IT S FAST Just slip components together and secure with sheet metal screws. No caulking, no taping. Seals tight the first time. Weather independent installation. IT S ATTRACTIVE No unsightly duct sealer. Great for concealed jobs & exposed installations. IT S COST EFFECTIVE SPIROsafe installs up to 30% faster than traditional duct work. IT S GUARANTEED It comes with a 10 year factory warranty Gripple Fastener Model Length Weight Rating HF Feet 100 lbs. HF Feet 100 lbs. HF Feet 100 lbs. HF Feet 200 lbs. HF Feet 200 lbs. HF Feet 200 lbs. Gripple, Advantages & Benefits Reduced installation by up to 6 times compared to; Rod, Chain or Hanger. Fast, Strong & Lightweight solution to the task of hanging HVAC services. Allows the installer to position the hangers vertically or at an angle. Less invasive than threaded rod and other traditional methods. Available in; Loop or Stud end fixings. 6

9 SPIROsafe Self Sealing Spiral Duct System (Patented Double Lipped Gasket BSU90 Stamped BSFU90 Gored BU90 Short Radius BSU45 Stamped BSFU45 Gored SR-Spiral Duct RCU Conc. Reducer PSU 90 Saddle Tap NPU-Duct to Duct MF-Fitting to Fitting ILRU-Bellmouth Takeoff ILU Straight Takeoff Contact Elite Air Systems for quotes on other Lindab products, special sizes and special construction: stainless steel, PVC, aluminum, double wall & flat oval DSU-Bal. Damper ESU-Duct End Cap 7

10 Pipe 90 Elbows 45 Elbows Couplings Take-Offs End Cap Damper Size Diameter SR Duct 10 Ft. BSU Stamped BSFU Gored BSU Stamped BSFU Gored NPU Small End MF Large End ILRU Bell Mouth ILU Straight ESU DSU 4" x x x x x x x x 5" x 6" x x x x x x x x 7" x x x x x x x x 9" x x x x x x x x 10" x x x x x x x x 12" x x x x x x x x 14" x x x x x x x x 16" x x x x x x x x 18" x x x x x x x x 20" x x x x x x x x 22" x x x x x x 24" x x x x x x X = In Stock 6 to 24 spiral pipe is corrugated for added strength Model RCU Reducer Large End Dia. Small End Dia. Stock X = In Stock 6" 4" x 8 6" & 4" x 10" 8", 6" & 4" x 12" 10", 8" & 6" x 14" 12", 10" & 8" x 16" 14", 12" & 10" x 18" 16" & 14" x 20" 18" & 16" x 22" 20" & 18" x 24" 22" & 20" x Model PSU Saddle Taps Take-Off Dia. Main Duct Dia. Stock 4" 6" & 8" x 6" 6" thru 12" x 8" 10" thru 16" x 10" 12" thru 22" x 12" 14" thru 24" x 14" 16" thru 24" x 16" 16" thru 24" x 18" 18" thru 24" x X = In Stock Gauges per SMACNA 2005 Diameter (in) Spiral Duct Fittings 3" to 14" 28 Gauge 28 Gauge 16" to 24" 26 Gauge 26 Gauge Spiral available in smooth or corrugated finish 8

11 Lindab Galvanized Register Model RGS3 No saddle tap or grill box required Register Nominal Size (in) Register Model # RGS3 Minimum Duct Diameter (in) CFM Duct Opening A x B (in) 13" x 3" /4" x 3" 17" x 3" /4" x 3" 21" x 3" /8" x 3" 25" x 3" /8" x 3" 33" x 3" /2" x 3" 13" x 6" /4" x 6" 17" x 6" /4" x 6" 21" x 6" /8" x 6" 25" x 6" /8" x 6" 33" x 6" /2" x 6" 13" x 9" /4" x 8 7/8" 17" x 9" /4" x 8 7/8" 21" x 9" /8" x 8 7/8" 25" x 9" /8" x 8 7/8" 33" x 9" /2" x 8 7/8" Benefits of the Lindab Safe system Can be installed in all weather conditions. Double lipped gasket minimizes the risk of leakage in the event of damage. Manufactured to published tolerance standard. Smoke Developed = 5 in accordance w/ ASTM std. Factory installed gasket - no loose parts. Adjustability - fittings can be rotated 360 degree's during installation and still maintain the seal's integrity. Rolled over edges for easier installation, reduces risk of injury and adds strength. Performance rated from -20 degree F to +212 degree F. Meets SMACNA's Leakage Class 3 integrity from -20 in W.G. to +12 in W.G. Gasket U.L. classified (ratings of Flame Spread = 0 Installs up to 30% faster than traditional duct work. 9

12 Light Duct Systems Round Snap Lock Pipe Galvanized Crimped end 60" length standard 90 Elbows Galvanized Adjustable 45 Elbows Galvanized Adjustable Size Diameter 5 Foot / 26 Gauge 4 x 5 x 6 x 7 x 8 x 9 x 10 x 12 x 14 x Size Diameter 26 Gauge 4 x 5 x 6 x 7 x 8 x 9 x 10 x 12 x 14 x Size Diameter 26 Gauge 4 x 6 x 8 x 10 x 12 x 14 x Diameter (large end) Diameter (small end) 26 Gauge 4 3 x 5 3 x 5 4 x 6 3 x 6 4 x 6 5 x 7 4 x 7 5 x 7 6 x 8 4 x 8 5 x Conical Reducers Galvanized Diameter (large end) Conical Reducer (con't) Diameter (small end) 26 Gauge 8 6 x 8 7 x 9 6 x 9 7 x 9 8 x 10 5 x 10 6 x 10 7 x 10 8 x 10 9 x 12 6 x 12 7 x 12 8 x 12 9 x x 14 8 x 14 9 x x x 10

13 End Caps Galvanized Crimped end 4-14 diameter Tees Galvanized 4-14 diameter Damper Kit Galvanized 6-12 diameter X = Stock X = Stock X = Stock Diameter 26 Gauge 4 x 5 x 6 x 7 x 8 x 9 x 10 x 12 x 14 x Diameter Diameter (trunk) (branch) 26 Gauge 4 4 x 5 5 x 6 6 x 7 7 x 8 8 x x x x Size Diameter 30 Gauge 6 x 7 x 8 x 10 x 12 x Low Velocity Damper Galvanized 4-14 diameter X = Stock Size Diameter 26 Gauge 4 x 5 x 6 x 7 x 8 x 9 x 10 x 12 x 14 x Collars Spin in Galvanized 4-14 diameter (Does not include A tabs) X = Stock Size Diameter 26 Gauge 4 x 5 x 6 x 7 x 8 x 9 x 10 x 12 x 14 x 11

14 Collar Spin in w/ Damper Galvanized 4-14 diameter X = Stock Size Diameter 26 Gauge 4 x 5 x 6 x 7 x 8 x 9 x 10 x 12 x 14 x Airtight Stick on w/ Dmpr Galvanized 4-14 diameter X = Stock Size Diameter 26 Gauge 4 x 5 x 6 x 7 x 8 x 9 x 10 x 12 x 14 x TAPES & GASKETS Foil Tape Peel & Seal #440 Butyl Gasket Duct Tape FSK Tape Foil Tape available in 2" & 3" (purchase by the roll or the case) Peel & Seal available in 3" (purchase by the roll or the case) Butyl Gasket (purchase by the foot) Duct Tape available in 2" (purchase by the roll or the case) FSK Tape available in 3" (purchase by the roll or the case) 12

15 Access Doors CAD(B) Cammed Access Door Tab Style Door: 24 Ga. double panel 12x12 and smaller. 22 Ga. Double panel 14x14 and larger Frame: 24 Ga. Galvanized steel with 5/8 notched knockouts. Insulation: 1.5# density fiberglass Liner Gasket: 1/8 neoprene Latches: zinc plated, self tightening, hand operated camlock CAD(C) Cammed Access Door Stick On Style Door: 24 Ga. double panel 12x12 and smaller. 22 Ga. Double panel 14x14 and larger Frame: 24 Ga. Galvanized steel with adhesive backing. Insulation: 1.5# density fiberglass Liner Gasket: 1/8 neoprene Latches: zinc plated, self tightening, hand operated camlock CAD(A) Cammed Access Door Tab Style Door: 24 Ga. double panel 12x12 and smaller. 22 Ga. Double panel 14x14 and larger Frame: 24 Ga. galvanized steel with 5/8 notched knockouts. Insulation: 1.5# density fiberglass Liner Gasket: 1/8 neoprene Latches: zinc plated, self tightening, hand operated camlock Hinge: 2 Aluminum piano hinge with stainless steel pin CAD(H) Cammed Access Door Stick On Style Door: 24 Ga. double panel 12x12 and smaller. 22 Ga. Double panel 14x14 and larger Frame: 24 Ga. galvanized steel with adhesive backing. Insulation: 1.5# density fiberglass Liner Gasket: 1/8 neoprene Latches: zinc plated, self tightening, hand operated camlock Hinge: 2 Aluminum piano hinge with stainless steel pin Size in Stock (all styles) 6x6 14x14 8x8 16x16 10x10 18x18 12x12 24x24 13

16 ACE Downblast Centrifugal Roof Exhauster Description - Fan shall be a spun aluminum, roof mounted downblast centrifugal exhaust vent. Construction - Fan shall be of bolted and welded construction utilizing corrosion resistant fasteners. The spun aluminum structural components shall be constructed of minimum 16 gauge marine alloy aluminum, bolted to a rigid aluminum support structure. The aluminum base shall have continuously welded curb cap corners for maximum leak. The discharge baffle shall have a rolled bead for added strength. An integral conduit chase shall be provided through the curb cap and into the motor compartment to facilitate wiring connections. Motor - shall be heavy duty type with permanently lubricated sealed bearing and furnished at the specified voltage, phase and enclosure. Motor shall be a NEMA "B", class "B" insulation rated for continuous duty. Bearings - shall be designed and individually tested specifically for use in air handling applications. Construction shall be heavy duty regreasable ball type in a cast iron pillowblock housing selected for a minimum L50 life in excess of 200,000 hours ACE-D Direct Drive Dimension Data Size A B C G T Sq. Roof Opening Square Shipping Weight /4 13-5/8 13-3/ / /2 18-3/4 16-3/ / /2 18-3/ / / / / / / / / / / / /8 29-3/ /2 90 ACE-B Belt Drive Dimension Data Roof Opening Shipping Size A B C G T Sq. Square Weight /8 23-9/ / / /8 23-9/ / / /8 23-9/ / / / / / / / / / / / /8 28-7/ / / /8 29-3/ / / / / / /8 47-5/8 39-7/ / / /8 49-1/ / / /8 51-9/ /2 380 ACE-D Direct Drive Performance Data Model # HP RPM Tip Speed 0" SP.125" SP.25" SP.375" SP.50" SP.75" SP 70C15DL C15DM 1/ C15DH C15DL C15DM 1/ C15DH C15DL C15DM 1/ C15DH C17D 1/ C17D 3/ C10D 1/

17 ACE Downblast Centrifugal Roof Exhauster ACE-B Belt Drive Performance Data Model # HP RPM Tip Speed 0" SP.125" SP.25" SP.375" SP.50" SP.75" SP C3B 1/ C38 1/ C3B 1/ C3B 1/ C4B 1/ C3B 1/ C5B 1/ C3B 1/ C4B 1/ C5B 1/ C6B 3/ C3B 1/ C4B 1/ C5B 1/ C6B 3/ C3B 1/ C4B 1/ C5B 1/ C6B 3/ C7B C8B C9B C3B 1/ C4B 1/ C5B 1/ C6B 3/ C7B C8B C9B C4B 1/ C5B 1/ C6B 3/ C7B C8B C9B C10B C11B C6B 3/ C7B C8B C9B C10B C11B Performance certified is for installation Type A: free inlet, free outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories) in the airstream. The sound ratings shown are loudness values in fan sones at 5 ft. in a hemispherical free field calculated per AMCA Standard 301. All ACE-D & ACE-B Units are Stocked with Bird Screen, Prewired Disconnect & Gravity Damper 15

18 ACRU Upblast Centrifugal Roof Exhauster Description - Fan shall be a spun aluminum, roof mounted upblast centrifugal exhaust vent. Construction - Fan shall be of bolted and welded construction utilizing corrosion resistant fasteners. The spun aluminum structural components shall be constructed of minimum 16 gauge marine alloy aluminum, bolted to a rigid aluminum support structure. The aluminum base shall have continuously welded curb cap corners for maximum leak. The discharge baffle shall have a rolled bead for added strength. An integral conduit chase shall be provided through the curb cap and into the motor compartment to facilitate wiring connections. Motor - shall be heavy duty type with permanently lubricated sealed bearing and furnished at the specified voltage, phase and enclosure. Motor shall be a NEMA "B", class "B" insulation rated for continuous duty. Bearings - shall be designed and individually tested specifically for use in air handling applications. Construction shall be heavy duty regreasable ball type in a cast iron pillowblock housing selected for a minimum L50 life in excess of 200,000 hours. ACRU-D Direct Drive Dimension Data Size A B C G T Sq. Roof Opening Shipping Square Weight / / / / / / / / / / / /2 90 ACRU-B Belt Drive Dimension Data Size A B C G T Sq. Roof Opening Shipping Square Weight /6 30-3/ / / / / / / / / / / / / / / / /4 38-1/ / /2 49-1/4 41-1/ / /8 54-1/ / /2 336 ACRU-D Direct Drive Performance Data Model # HP RPM Tip Speed 0" SP.125" SP.25" SP.375" SP.50" SP.75" SP 120R11D 1/ R11D 1/ R10D 1/

19 ACRU Upblast Centrifugal Roof Exhauster ACRU-B Belt Drive Performance Data Model # HP RPM Tip Speed 0" SP.125" SP.25" SP.375" SP.50" SP.75" SP 120R3B 1/ R4B 1/ R3B 1/ R4B 1/ R5B 1/ R3B 1/ R4B 1/ R5B 1/ R6B 3/ R3B 1/ R4B 1/ R5B 1/ R6B 3/ R7B R8B R9B R3B 1/ R4B 1/ R5B 1/ R6B 3/ R7B R8B R9B R3B 1/ R4B 1/ R5B 1/ R6B 3/ R7B R8B R9B R3B 1/ R4B 1/ R5B 1/ R6B 3/ R7B R8B R9B R10B R11B Performance certified is for installation Type A: free inlet, free outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories) in the airstream. The sound ratings shown are loudness values in fan sones at 5 ft. in a hemispherical free field calculated per AMCA Standard

20 VCR Restaurant Duty Upblast Roof Exhauster Description - Fan shall be a spun aluminum, roof mounted upblast centrifugal exhaust vent. Construction - Fan shall be of bolted and welded construction utilizing corrosion resistant fasteners. The spun aluminum structural components shall be constructed of minimum 16 gauge marine alloy aluminum, bolted to a rigid aluminum support structure. The aluminum base shall have continuously welded curb cap corners for maximum leak. The discharge baffle shall have a rolled bead for added strength. An integral conduit chase shall be provided through the curb cap and into the motor compartment to facilitate wiring connections. Motor - shall be heavy duty type with permanently lubricated sealed bearing and furnished at the specified voltage, phase and enclosure. Motor shall be a NEMA "B", class "B" insulation rated for continuous duty. Bearings - shall be designed and individually tested specifically for use in air handling applications. Construction shall be heavy duty regreasable ball type in a cast iron pillowblock housing selected for a minimum L50 life in excess of 200,000 hours. Certifications - UL762 Listed for Restaurant Exhaust Applications VCR Belt Drive Dimension Data Size A B C G T Sq. Roof Opening Shipping Square Weight / / / / / / / / / /4 38-1/ / /2 49-1/4 41-1/ / /8 54-1/ / /2 336 VCR Belt Drive Performance Data Model # HP RPM Tip Speed 0" SP.125" SP.25" SP.375" SP.50" SP.75" SP 135V3B 1/ V4B 1/ V5B 1/ V3B 1/ V4B 1/ V5B 1/ V6B 3/ V3B 1/ V4B 1/ V5B 1/ V6B 3/ V7B V8B V9B V3B 1/ V4B 1/ V5B 1/ V6B 3/ V7B V8B V9B V3B 1/ V4B 1/ V5B 1/ V6B 3/ V7B V8B V9B V10B V11B

21 SQN-B Centrifugal Inline Fan Description - Fan shall be duct mounted, belt driven centrifugal square inline. Construction - The fan shall be bolted construction utilizing corrosion resistant fasteners. Housing shall be minimum 18 gauge galvanized steel with integral duct collars. Bolted access door shall be provided on three sides, sealed with closed cell neoprene gasketing. Pivoting motor plate shall utilize threaded L- bolt design for positive belt tensioning. Housing shall be pr-drilled to accommodate universal mounting feet for vertical or horizontal installation. Motor - shall be heavy duty type with permanently lubricated sealed bearing and furnished at the specified voltage, phase and enclosure. Motor shall be a NEMA "B", class "B" insulation rated for continuous duty. Bearings - shall be designed and individually tested specifically for use un air handling applications. Construction shall be heavy duty regreasable ball type in a cast iron pillowblock housing selected for a minimum L50 life in excess of 200,000 hours. SQN-B Belt Drive Dimension Data Size A B C D sq. Inlet Discharge Duct Size (ID) Shipping Weight sq sq /16 16 sq /8 23-7/ sq /8 24 sq sq SQN-B CFM OV.25" SP.50" SP.75" SP 1.0" SP RPM BHP RPM BHP RPM BHP RPM BHP SQN-B CFM OV.25" SP.50" SP.75" SP 1.0" SP RPM BHP RPM BHP RPM BHP RPM BHP

22 SQN-B Centrifugal Inline Fan 120 SQN-B CFM OV.25" SP.50" SP.75" SP 1.0" SP RPM BHP RPM BHP RPM BHP RPM BHP SQN-B CFM OV.25" SP.50" SP.75" SP 1.0" SP RPM BHP RPM BHP RPM BHP RPM BHP SQN-B CFM OV.25" SP.50" SP.75" SP 1.0" SP RPM BHP RPM BHP RPM BHP RPM BHP SQN-B CFM OV.25" SP.50" SP.75" SP 1.0" SP RPM BHP RPM BHP RPM BHP RPM BHP For extended performances please refer to your Loren Cook catalog or contact All SQN-B Inline units are stocked with a Prewired Disconnect Switch. 20

23 GC Ceiling Fans GC GC-184 Description - Fan shall be ceiling mounted, direct driven, centrifugal exhaust fan. Construction - The fan housing shall be minimum 20 gauge galvanized steel and acoustically insulated. Blower and motor assembly shall be mounted to a minimum 14 gauge reinforcing channel and shall be easily removable from the housing. Motor shall be mounted vibration isolators. Unit shall be supplied with integral wiring box and disconnect receptacle shall be standard. Discharge position shall be convertible from right angle to straight through by moving interchangeable panels. The outlet duct collar shall include a reinforced aluminum damper with continuous aluminum hinge rod and brass bushings. To accommodate different ceiling thickness, an adjustable prepunched mounting bracket shall be provided. A powder painted white steel grille shall be provided as standard. Unit shall be shipped in ISTA Certified Transit Tested Packaging. Wheel - shall be centrifugal forward curved type, injection molded of polypropylene resin on GC-120 through GC-184 and galvanized steel on GC GC-862. Wheel shall be balanced in in accordance with AMCA Standard , Balance Quality and Vibration Levels for Fans. Motor - shall be open drip proof type with permanently lubricated sealed bearings and include impedance or thermal overload protection and disconnect plug. GC Dimension Data Grille A B Material Plastic 13-1/4 " 15-1/2 " GC GC-740 Steel 13-1/2 " 15-1/2 " Aluminum 13-3/4 " 15-1/2 " Unit Size Approx. Ship-Wt 122/ # 142/ # 162/ # 182/ # GC GC-960 GC GC-960 Housing Outlet Plastic Grille Steel Grille Aluminum Grille Approx Model GC Ship Wt. L W H A B J K J K J K Lbs. 220, /8 9 3/4 9 3/ /8 14 1/ /2 13 1/4 16 3/8 320, /8 10 3/4 10 3/ /4 12 1/ /4 18 3/4 13 3/ /8 11 7/ /4 18 3/4 13 3/ , /4 18 3/4 13 3/ /8 11 7/8 10 1/2 4 3/4 720, /4 18 3/4 13 3/ , 842, /8 17 1/8 28 3/4 16 1/ /3 14 2/ , 940, /8 17 1/8 32 3/4 16 1/

24 GN Inline Fans GN GN-184 Description - Fan shall be inline mounted, direct drive, centrifugal exhaust fan. Construction - Fan housing shall be minimum 20 gauge galvanized steel and acoustically insulated. Blower and motor assembly shall be mounted to a minimum 14 gauge reinforcing channel and shall be easily removable from the housing. Motor shall be mounted on vibration isolators. Unit shall be supplied with integral wiring box and receptacle and disconnect receptacle shall be standard. Discharge position shall be convertible from right angle to straight through by moving interchangeable panels. The outlet duct collar shall include a reinforced aluminum damper with continuous aluminum hinge rod and nylon bushings. To accommodate different mounting positions, an adjustable prepunched mounting bracket shall be provided. Unit shall be shipped in ISTA Certified Transit Tested Packaging. Wheel - shall be centrifugal forward curved type, injection molded of polypropylene resin on GC-120 through GC-184 and galvanized steel on GC GC-862. Wheel shall be balanced in in accordance with AMCA Standard , Balance Quality and Vibration Levels for Fans. Motor - shall be open drip proof type with permanently lubricated sealed bearings and include impedance or thermal overload protection and disconnect plug. GN Dimension Data GN GN-740 Unit Size Approx. Ship-Wt 122/ # 142/ # 162/ # 182/ # GN GN-960 GN GC-960 Housing Outlet Inlet Collar Approx Model GN Ship Wt. L W H A B J K Lbs. 220, /8 9 3/4 9 3/ / , /8 10 3/4 10 3/ /8 11 7/ , /8 11 7/8 10 1/2 4 3/4 10 1/2 4 3/4 720, , 842, / / , 940,

25 GC Ceiling Performance Data Model GC Max Watts RPM Sones 0" SP.1" SP.125" SP.25" SP.375" SP.50" SP.75" SP CFM CFM CFM CFM CFM CFM CFM GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GC GN Inline Performance Data Model GN Max Watts Sones 0" SP.1" SP.125" SP.25" SP.375" SP.50" SP.75" SP RPM SP CFM CFM CFM CFM CFM CFM CFM GN GN GN GN GN GN GN GN GN GN GN GN GN GN GN GN GN GN GN GN GN GN BHP GN BHP GN BHP

26 Gemini Accessories Speed Controllers Cook's FSC is a variable speed controller which can offer excellent energy conservation and lower sound levels when 100 percent of a direct drive fan operating capacity is not required. The FSC employs solid state circuitry for long life dependability. The FSC is available only on 115 volt and 230 volt shaded pole or permanent split capacitor direct drive motors and is not available on 1140 RPM and 1725 RPM motors. The FSC is shipped loose for field installation. Time Delay Switches The time delay switch operates both the fan and the room light. Moving the switch to the "on" position turns the light on immediately and the exhaust fan on 15 seconds later. Both light and fan stay on until the switch is moved to the "off" position. When the switch is moved to the "off" position, power to the light is immediately ceased and the fan will power down 1 to 10 minutes dependent upon the adjustable delay. Gem Hanging Iso. Kits The Gemini Hanging Isolator Kit is used for Gemini ceiling and inline units 122 through 740. Bushings are made of resilient thermoplastic. The bushings and eyelets are sized to be used with common 1/4" x 20 all thread. Standard Gemini mounting brackets easily accommodate the isolator bushings. Flanged nusts eliminate the need for additional washers and provide for a more simplified field assembly. Rated Load = 160 lbs. Rubber In Shear Iso. Spring Isolators Ceiling Mounted RC-75 Rated for 75 lbs. Brick Vents SC-70 Rated for 70 lbs. Brick Vent Dimension Data Gemini Series Model # A B C BV-1 4-3/4 16-1/ BV-2 4-3/4 16-1/ BV-5 7-3/4 16-1/ BV All dimensions in inches. Frame and blades are constructed from.125" thick materials. Designed for maximum protection against water entering building with 4" deep frame and 45 degree blades. Vents comes standard with 24

27 Gemini Accessories Wall Caps Round Duct Round Duct Wall Cap w/ Damper Dimensions Gemini # Model # A sq. B C Dia D E WCR /2 12-3/ WCR /2 14-3/4 All dimensions in inches. Construction is aluminum w/ integral backdraft damper All stocked with bird screen and backdraft damper available (exhaust only) Wall Caps Rect Duct Wall Cap Dimension Data Gemini # Alum A B C D WCA /16 7-3/16 6-3/8 8-5/ WCA / / WCA /16 7-3/16 6-3/ / WCA / / / /16 All dimensions in inches. Construction is aluminum w/ 1/2" birdscreen Roof Caps Roof Cap Dimension Data Gemini # Model # Type A B C Throat PR8 Curb mtd. 18-1/4 10-1/ /32 PR8F Flat 18-1/4 8-1/ / PR12 Curb mtd. 28-1/4 10-5/ /2 PR12F Flat 28-1/4 8-5/ / PR16 Curb mtd. 28-1/4 12-5/ /2 PR16F Flat 28-1/4 10-5/ /2 All dims. in inches. Construction is aluminum w/ integral backdraft damper. All stocked with bird screen and backdraft damper available (exhaust only) Roof Jacks Roof Jack Dimension Data Model # A B C D E Throat RJR /4 18-3/4 10-3/8 14-1/2 6-1/2 6 Dia. RJ /4 18-3/4 10-3/8 14-1/2 6-1/2 10-3/4 sq All dims. in inches. Construction is aluminum w/ 1/2 birdscreen. Roof Curbs Roof Curb Dimension Data Roof Cap # Model # F sq. V sq. W sq. Roof Opening Height PR8 RCG /2 20-1/2 9-3/4 13-1/ PR12 RCG /2 22-1/2 11-3/4 15-1/ PR16 RCG-26 26'1/2 30-1/2 19-3/4 23-1/ PR20 RCG /2 34-1/2 23-3/4 27-1/ All dimensions in inches. Curbs are galvanized w/ damper tray and wood nailer. 25

28 XMW Belt Drive Axial Wall Fan SWD and XMW Accessories Description - Fan Shall be a wall mounted, belt driven, steel propeller exhaust fan. Construction - Construction - The fan shall be of bolted and welded construction utilizing corrosion resistant fasteners. The motor, bearings and drives shall be mounted on a minimum 14 gauge steel power assembly. The power assembly shall be bolted to a minimum 14 gauge wall panel with continuously welded corners and an integral venturi. Unit shall bear an engraved aluminum nameplate. Unit shall be shipped in ISTA Certified Transit Tested Packaging. Coating - All steel fan components shall be Lorenized with an electrostatically applied, baked polyester powder coating. Propeller - shall be a high-efficiency fabricated steel design with blades securely fastened to a minimum 7 gauge hub. Bearings - L50 life in excess of 200,000 hours. Motor - shall be heavy duty type with permanently lubricated sealed ball bearings and furnished at the specified voltage, phase and enclosure. XMW Belt Drive Dimension Data Size A B C D E Wall Opening Wt. Shipping / /16 6-3/ / / /16 6-3/ / / /16 7-3/ / / /16 7-7/ / See next page for XMW performance tables Size / Model # WO (Wall Opening) SWD XMW A B Wire Std. Fan Guard / / / / / / / / /2 30-7/ / /2 36-7/ / /2 42-7/ / /2 54-7/ /8 Typical Installation Exhaust Wall Fan with OSHA Wire Guard and Shutter Weather Hood Optional (Not a Stock Item) 26

29 XMW Belt Drive Performance Data Fan Size Model # Motor HP Max BHP RPM FA Sones CFM vs. Static Pressure 0" SP.1" SP.125" SP.25" SP.375" SP / / XMW / / / / / XMW / / / XMW / / / XMW Stocking Exhaust Units only All units are stocked with prewired disconnect, gravity shutter, wall collar and rear guard 27

30 SWD Direct Drive Axial Wall Fan SWD Direct Drive Performance Data Description - Fan shall be a wall mounted, direct driven, propeller exhaust fan. Construction - Fan shall be a bolted and welded construction utilizing corrosion resistant fasteners. The motor shall be mounted on a 12 gauge steel wire guard. The wired guard shall be bolted to a minimum 14 gauge steel panel with continuously welded corners and an integral venturi. Unit shall bear an engraved aluminum nameplate which will indicate CFM and static pressure. Unit shall be shipped in ISTA Certified Transit Tested Packaging. Coating - All steel fan components shall be Lorenized with an electrostatically applied, baked polyester powder coating. Each component shall be subject to a five stage environmentally friendly wash system, followed by a 1.5 to 2.5 mil thick baked powder finish. Propeller - shall have aluminum blades riveted to a painted steel hub. Motor - shall be 115/1/60, open drip-proof type. SWD Direct Drive Dimension Data Size A B C D E F Wall Opening /16 4-3/4 1-1/2 10-3/ /8 16-7/ /16 4-3/4 1-3/4 12-3/ / / / /16 2-1/2 16-3/ /4 20-7/ / /16 2-3/4 18-3/ /4 24-7/16 All dimensions in inches CFM vs. Static Pressure Fan Size Model # Motor HP Max BHP RPM FA Sones 0" SP.1" SP.125" SP.25" SP.375" SP S15D 1/ S15D 1/ S10D 1/ S10D 1/ All units are stocked with a prewired disconnect, gravity wall shutter, wall collar and rear guard 28

31 GI/GR Gravity Hoods Description - Unit shall be a hooded high efficiency roof mounted gravity ventilator. Construction - The unit shall be bolted and welded construction utilizing corrosion resistant fasteners. The hood shall be constructed of minimum 18 gauge aluminum, bolted to a minimum 8 gauge aluminum support structure. A radius throat must be provided for optimum performance. Lifting lugs shall be provided to help prevent damage from improper lifting. A rain gutter shall be provided to prevent rain infiltration. The base shall have continuously welded curb cap corners for maximum leak protection. Birdscreen constructed of 1/2" galvanized mesh shall be mounted in the hood. GI/GR Dimension Data Throat Hood Curb Cap Hood Ht. Shipping Wt. 12" x 12" 28" x 24" 17.5" sq. 11" 92 lbs. 18" x 18" 29" x 36" 23.5" sq. 12" 121 lbs. 24" x 24" 48" x 36" 29.5" sq. 14" 153 lbs. 30" x 30" 56" x 48" 35.5" sq. 20" 208 lbs. 36" x 36" 65" x 60" 41.5" sq. 22" 252 lbs. All dimension in inches. GI/GR Performance Data Static Pressure Drop (in W.G.) Ducted Throat Non-Ducted Hood Velocity (FPM) Throat Area (ft²) Hood Area (ft²) CFM 12" x 12" " x 18" " x 24" " x 30" " x 36" PR Gravity Roof Caps Description - Unit shall be a spun aluminum, roof mounted gravity ventilator. Construction - The unit shall be of bolted and welded construction utilizing corrosion resistant fasteners. The spun aluminum structural components shall be constructed of minimum 16 gauge marine alloy aluminum, bolted to a rigid aluminum support structure. The aluminum base shall have continuously welded curb cap corners for maximum leak protection. The spun aluminum baffle shall have a rolled bead for added strength. Bird screen constructed of 1/2" mesh. PR Dimension Data Size A Dia. B Dia. C D G T Sq. Roof Opening 8 8-1/2 18-1/4 4-5/8 3-1/ / /2 28-1/4 4-13/16 3-1/ / /2 28-1/4 5-1/8 5-1/ / /2 36-1/2 6-3/4 4-7/ /2 PR Performance Data CFM Size

32 CPS Backward Inclined Steel Vent Set Description - Fan shall be a single width, single inlet, backward inclined flat blade vent set. Construction - The fan shall be bolted and welded construction utilizing corrosion resistant fasteners. The scroll wrapper shall be minimum 14 gauge steel. The entire fan housing shall have continuously welded seams for leak proof operation. The fan housing shall be field rotatable to any one of eight discharge positions and shall have a minimum 1-1/2 inch outlet discharge flange. Bearing support shall be minimum 10 gauge welded steel. Side access inspection ports shall be provided with quick release latches for access to the motor compartment without removing the weather cover. Lifting lugs shall be provided for ease of installation. Coating - Steel fan components shall be Lorenized with an electrostatically applied, baked polyester powder coating. Wheel - shall be steel centrifugal backward inclined, non-overloading flat blade type. Bearings - shall be designed and tested specifically for use in air handling applications. Construction shall be heavy duty regreasable ball or roller type in a cast iron pillowblock housing selected for a minimum L50 life in excess of 200,000 hours. Rotation and Discharge The direction of rotation is determined from the drive side of the fan. On single inlet fans, drive side is always considered as the side opposite the fan inlet. The angle of the discharge is based on the horizontal axis of the fan and is designated in degrees (45 standard) above or below the standard reference axis. CPS Dimension Data Size A B C D E F G H J M / / / /4 12-3/4 9-3/8 25-1/ / / / /4 17-5/ / /8 9-3/ / / / / / / /4 17-5/8 10-3/8 33-9/ /8 15-1/ / / / /8 45-1/ /4 13-3/8 44-5/8 22-7/8 18-1/8 Size N P Q R S U V W X Ship Wt /8 30-3/ /16 1-1/2 8-1/16 4-1/ / /8 34-3/ /16 1-1/2 8-1/16 4-1/ / /8 43-1/ /16 9/16 1-1/2 9-1/16 4-1/ / /8 58-1/ /16 11/ /16 5-1/ /

33 CPS Performance Data 100 CPS CFM OV 1.0" SP 1.50" SP 2.0" SP 3.0" SP RPM BHP RPM BHP RPM BHP RPM BHP CPS CFM OV 1.0" SP 1.50" SP 2.0" SP 3.0" SP RPM BHP RPM BHP RPM BHP RPM BHP CPS CFM OV 1.0" SP 1.50" SP 2.0" SP 3.0" SP RPM BHP RPM BHP RPM BHP RPM BHP CPS CFM OV 1.0" SP 1.50" SP 2.0" SP 3.0" SP RPM BHP RPM BHP RPM BHP RPM BHP For extended performances please refer to your Loren Cook catalog or contact 31

34 Bathroom Fans Ultra-Quiet - High Performance Ceiling Fans Model #.1" SP.25" SP.50" SP AMPS Watts QTRE080 CFM Sones QTRE110 CFM Sones Ceiling Exhaust Fans Model Volts Amps RPM Sones SP Duct " Round Model Volts Amps RPM Sones SP Duct " Round Model # 0" SP.25" SP.375" SP AMPS Watts CFM Sones Ceiling Exhaust Fan / Light Combo Model Volts Amps RPM Sones CFM Duct " Round " Round " Round Heavy Duty Ceiling Fan / Light Combo Model # 0" SP.25" SP.50" SP AMPS Watts CFM HD80L Sones Dimensional Data Model # Width Length Height Outlet Grille Weight QTRE " 10.5" 7.625" 4" Round 13" x 14" 11.8 lbs. QTRE " 10.5" 7.625" 4" Round 13" x 14" 11.8 lbs " 7.5" 3.625" 3" Round 9" Sq. 4.0 lbs " 8.25" 5.75" 4" Round 11" Sq. 7.0 lbs " 8.25" 5.75" 4" Round 11" Sq. 6.5 lbs " 8.25" 5.75" 4" Round 11" Sq. 6.0 lbs " 8.25" 5.75" 4" Round 11" Sq. 6.5 lbs " 8.25" 5.75" 4" Round 11" Sq. 7.0 lbs. HD80 8.0" 8.25" 5.75" 4" Round 11" Sq. 7.1 lbs. 32

35 Bathroom Fans Lo-Sone Select Ceiling Fans Model # 0" SP.25" SP.50" SP AMPS Watts CFM L100 Sones Model # 0" SP.25" SP.50" SP AMPS Watts CFM L150 Sones Model # 0" SP.25" SP.50" SP AMPS Watts CFM L200 Sones Model # 0" SP.25" SP.50" SP AMPS Watts CFM L250 Sones Model # 0" SP.25" SP.50" SP AMPS Watts CFM L300 Sones Heavy Duty Ceiling Fans Model # 0" SP.25" SP.50" SP AMPS Watts CFM HD80 Sones Through Wall Fan Model Volts Amps RPM Sones CFM Duct " Round " Round Dimensional Data Model # Width Length Height Outlet Grille Weight L " 12.25" 11.75" 6" Round 14" Sq lbs L " 12.25" 11.75" 6" Round 14" Sq lbs. L " 12.25" 11.75" 8" Round 14 " Sq lbs. L " 12.25" 11.75" 8" Round 14" Sq lbs. L " 12.25" 11.75" 8" Round 14" Sq lbs. HD80 8.0" 8.25" 5.75" 4" Round 10.25" Sq. 7.2 lbs " 14.25" 14.25" " Sq. 6.9 lbs " 14.25" 14.25" " sq. 7.1 lbs. 33

36 Broan Ventilation Fans Accessories 57W Variable Speed Controller 59W 60 Minute Time Delay Switch 72W Variable Speed Controller 636 Roof Cap w/ Damper 3 & 4 Duct Model 611 Flat Roof Cap for 8 Duct Model 611CM Curb Mounted Cap 8 Duct 612 Alum Flat Roof Cap for 12 duct 612 Alum Curb Mtd. Roof Cap for 12 duct 646 White Plastic Wall Cap for 6 Duct 641 Alum. Wall Cap for 6 Duct 643 Alum Wall Cap for 8 Duct 613 Alum Wall Cap for 12 Duct 34

37 Flexible Duct The # 1 Choice in Flexible Duct! Ask almost any contractor about what brand to use and chances are that he'll name Thermaflex & Flex-Vent. Its resistance to tears and punctures, its strength and willingness to maintain shape, and its uniformity in size makes fitting to elbows and connectors fast and efficient. Elite Air Systems stocks "insulated" and "non-insulated" duct. In both the Thermaflex line and Flex-Vent line. Thermaflex Flexible Duct M-KC INSULATED Reinforced Mylar Jacket Heavy woven, coated fiberglass core 16" WG pos (4"-10"), 2" WG neg -20F UL181 Class 1 Air Duct Material Greenguard IAQ Certified Greenguard Children & Schools Certified Diameter x Length R = 4.2 6" x 25' x 7" x 25' x 8" x 25' x 10" x 25' x 12" x 25' x 14" x 25' x 16" x 25' x x = in stock M-KE INSULATED Diameter x Length R = 4.2 6" x 25' x Acoustically rated CPE core. 7" x 25' x Reinforced Mylar jacket. 8" x 25' x 6" WG pos (4"-16"), 1" WG neg - 20F 10" x 25' x UL181 Class 1 Air Duct Material 12" x 25' x Greenguard IAQ Certified 14" x 25' x Greenguard Children & Schools Certified x = in 16" x 25' x stock KP INSULATED Black Polyethylene Jacket UL181 Class 1 Air Duct Material NFPA 90A-908 Fire Code Rated Rated to +10" WC; 5000 FPM Greenguard IAQ Certified Greenguard Children & Schools Certified Diameter x Length R = 4.2 6" x 25' x x 7" x 25' x x 8" x 25' x x 10" x 25' x x 12" x 25' x x 14" x 25' x x 16" x 25' x x x = in stock 35

38 Flexible Duct KM INSULATED Metalized Silver Jacket UL181 Class 1 Air Duct Material NFPA 90A-908 Fire Code Rated Rated to +10" WC; 5000 FPM Greenguard IAQ Certified Greenguard Children & Schools Certified Diameter R = 4.2 6" x 25' x 7" x 25' x 8" x 25' x 10" x 25' x 12" x 25' x 14" x 25' x 16" x 25' x x = in stock MC UN-INSULATED Diameter Stock 6" x 25' x Metalized Polyester Film Jacket 8" x 25' x UL Class 1 Air Duct Material 10" x 25' x NFPA 90A-908 Fire Code Rated 12" x 25' x Rated to +10" WC; 5000 FPM x = in stock FLEX FLOW ELBOWS Improves Airflow Efficiency Installs in Less Than 30 One Piece Design Fits 6 to 16 Duct No Additional Tools, Sealants or Insulation Required FLEXIBLE DUCT STRAPS Available in 36 and 48 Packages of 50 36

39 Combination Magnetic HOA Starters HOA Keypad with LED status lights indicating Hand/Off/Auto modes, run and overload conditions Voltage & dry contact inputs for auto run command allows for direct wiring from the automation system, thermostat or other sensor to the starter without the use of interposing relays Fireman s Override Damper Control Interlocks damper with starter ensuring proper sequence of operation Wide Range Class 1-30 Electronic Overload Multi-tap CPT input accepts all common motor voltages with Integrated secondary protection no fuses required 5 year warranty Single Phase HP Three Phase HP 120V 230V 208V 230V NEMA Size Part Number Starters are stocked with disconnect switch and a NEMA 1 enclosure. For starters without disconnect or in NEMA 4 (outdoor use) NEMA 12 (dust tight) or NEMA 7 (explosion Proof) contact Elite Air Systems. 460 V BAS1-9/J-G BAS1-18/J-G BAS1-32/J-G-40 Single Phase Starter / Overload On/Off Disconnect Switch with Recessed Hand/Auto Modes Run Status Verification Voltage & Dry Inputs for Auto Run Command System Override Mode (Fireman s, Occupancy or Manual) Wide Range Class 10 Electronic Overload Standard Single Gang Box Installation 5-Year warranty Single Phase HP 120V 230V Part Number 1 1 BAS-1P 37

40 Roof Curbs Description - Flat Roof Curb w/ Damper Tray and Wood Nailer Construction - 18 gauge, galvanized steel - 1-1/2", 3 lbs. acoustical insulation. Curbs come standard with damper tray and wood nailer. Model OD ID Height RCG-15 15" sq. 12" sq. 12" RCG " sq. 13.5" sq. 12" RCG " sq. 15.5" sq. 12" RCG " sq. 19.5" sq. 12" RCG " sq. 23.5" sq. 12" RCG " sq. 25.5" sq. 12" RCG " sq. 31.5" sq. 12" RCG " sq. 37.5" sq. 12" * Actual height is 13.5" with std. wood nailer Equipment Rails Description - Straight sided equipment rail / support. Construction - 16 gauge galvanized steel w/ internal reinforcements, 12" centers and 1-1/2" pressure treated wood nailer w/ metal cap. Size Length Height Width 18 18" 12" 4" 24 24" 12" 4" 30 30" 12" 4" 36 36" 12" 4" 42 42" 12" 4" 48 48" 12" 4" 60 60" 12" 4" 72 72" 12" 4" Pipe Portals PCC-1 - Cap package w/ 12" high straight sided roof curb. PCC-2 - Cap package w/ 12" high straight sided roof curb. PCC-3 - Cap package w/ 12" high straight sided roof curb. PCC-4 - Cap package w/ 12" high straight sided roof curb. PCC-5 - Cap package w/ 12" high straight sided roof curb. PCC-6 - Cap package w/ 12" high straight sided roof curb. 3-1/2 diameter collars accommodate noninsulated pipes 1/2 to 2-1/2 nom. 6-1/2 diameter collars accommodate noninsulated pipes 3 to 5 nom. 12 diameter collars accommodate noninsulated pipes 6 to 10 nom. 38

41 Engineering Notes Motor Data Nominal Amps Single Phase Full Load Current HP RPM (AMPS) 115 v 230 v 1/ / / / / / / / / / HP Motor Data Three Phase Full Load Current RPM (AMPS) 230 v 460 v 1/ / / / Type of Building Suggested Air Changes Minutes per Air Change Assembly Halls... 3 to 10 Auditoriums... 4 to 15 Bakeries... 1 to 3 Banks... 3 to 10 Bars... 2 to 4 Beauty Parlors... 2 to 5 Boiler Rooms... 2 to 4 Bowling Alleys... 2 to 8 Churches... 4 to 15 Dry Cleaners... 1 to 5 Factory (general ventilation)... 5 to 10 Garages (repairs)... 2 to 10 Generator Rooms... 2 to 5 Gymnasiums... 2 to 10 Kitchens... 1 to 3 Laundries... 2 to 5 Locker Rooms... 2 to 5 Machine Shops... 3 to 5 Offices... 2 to 8 Production Rooms... 1 to 2 Projection Rooms... 1 to 3 Recreation Rooms... 2 to 8 Restaurants... 5 to 10 Retail Stores... 3 to 10 Shops (general ventilation)... 3 to 10 Stores... 5 to 10 Theaters... 3 to 8 Toilets... 2 to 5 Transformer Rooms... 1 to 5 Waiting Rooms... 8 to 10 Warehouse... 2 to 10 To determine required CFM (Cubic feet of building space / Minutes per Air Change) 39

42 Fan Troubleshooting Guide Low Capacity or Pressure Incorrect direction of rotation - Make sure the fan rotates in same direction as the arrows on the motor or drive assembly Poor fan inlet conditions - There should be a straight, clear duct at the inlet. Improper wheel alignment. Excessive Vibration and Noise Damaged or unbalanced wheel. Belts too loose; worn or oily belts. Speed too high. Incorrect direction of rotation. Make sure the fan rotates in same direct as the arrows on the motor or drive assembly. Bearings need lubrication or replacement. Fan is operating in surge region. Design Criteria for Room Loudness Overheated Motor Motor improperly wired or incorrect voltage. Incorrect direction of rotation. Make sure fan rotates in same direction as the arrows on the motor or drive assembly. Cooling air diverted or blocked. Improper inlet clearance. Incorrect fan RPM. Overheated Bearings Improper bearing lubrication. Extensive belt tension. Room Type Sones Room Type Sones Auditoriums Manufacturing Areas Concert and Opera Halls 1.0 to 3 Heavy Machinery 25 to 60 Stage Theaters 1.5 to 5 Light Machinery 12 to 36 Movie Theaters 2.0 to 6 Assembly Lines 12 to 36 Semi-Outdoor Amphitheaters 2.0 to 6 Machine Shops 15 to 50 Lecture Halls 2.0 to 6 General Storage 10 to 30 Multi-purpose 1.5 to 5 Courtooms 3.0 to 9 Offices, Hotels & Public Buildings Auditorium Lobbies 4.0 to 12 Executive 2.0 to 6 Conference Rooms 1.7 to 5 Churches, Schools & Hospitals Halls and Corridors 5.0 to 15 Sanctuaries 1.7 to 5 Lobbies 4.0 to 12 Schools and Classrooms 2.5 to 8 Banquet Rooms 8.0 to 24 Recreation Halls 4.0 to 12 Ball Rooms 3.0 to 9 Kitchens 6.0 to 18 Individual Rooms / Suites 2.0 to 6 Libraries 2.0 to 6 Kitchens and Laundries 7.0 to 12 Laboratories 4.0 to 12 Garages 6.0 to 18 Corridors and Halls 5.0 to 15 Museums 3.0 to 9 Private Rooms 1.7 to 5 Post Offices 4.0 to 12 Wards 2.5 to 8 Courthouses 4.0 to 12 Operating Rooms 2.5 to 8 Banks 4.0 to 12 Lobbies and Waiting Rooms 4.0 to 12 Lounges 5.0 to 15 Fan Laws CFM varies directly with RPM - CFM 1 / CFM 2 = RPM 1 / RPM 2 SP varies with the square of the RPM - SP 1 / SP 2 = (RPM 1 / RPM 2 ) 2 HP varies with the cube of the RPM - HP 1 / HP 2 = (RPM 1 / RPM 2 ) 3 40

43 Terms and Conditions of Sale All orders placed by customer will be subject to the terms and conditions of sale set forth below. Any additional or different terms proposed by customer are deemed to be rejected unless expressly consented to in writing signed by an officer of Orders: All orders subject to acceptance by Elite Air Systems, Inc. Possession of this wholesale catalog does not constitute the right to purchase from Elite Air Systems, Inc. Minimum order net is $ Pricing: Please contact Elite Air Systems for quotes. customer's use of any attachment, feature, or software on or in conjuction with any item, element, or component which has not been furnished by Elite Air Systems, Inc. or which has not been approved in writing signed by an officer of E.A.S. d. Customer understands and agrees that Elite Air Systems Inc., its suppliers, and the manufacturers, developers, or distributors of the items, elements, and components of the goods sold by Elite Air Systems, Inc. has no intention, obligation, or duty to warrant and or represent the quality, performance and condition of such deliverables on their behalf. Payment Terms: For customers with established credit, terms are net thirty (30) calendar days from date of our invoice. For other approved customers we accept cash, check, Visa, MasterCard & Discover. Collection Fees: Customer agrees to pay all cost of collection, including, but not limited to, an attorney's fee equal to thirty percent (30%) of all sums due and outstanding, as well as court cost, if customer fails or refuses to pay the amount due in accordance to the terms above. Sales Tax: Prices are exclusive of Pennsylvania, New Jersey or Delaware sales tax. Elite Air Systems, Inc is required to charge sales tax on orders for which sales tax exemption certificate or resale certificate has not been furnished. Delivery: All stock items are normally available for customer pick-up. Orders can be also be shipped via common carrier or via Elite Air Systems. Title of goods remain with Elite Air Systems until payment in full has been received by Warranties: a. Customer may be entitled to the benefit from certain limited warranties provided directly by the manufacturer of the goods purchased. Elite Air Systems assumes no liability for nor any responsibility under said third party warranties unless such liability shall be specifically set forth in writing signed by an officer of b. Other than any standard warranties provided by the manufacturers, there are no other warranties provided by, expressed or implied and disclaims all warranties including warranties of merchantability, fitness for a particular purpose, and non-infringement of third party rights. c. Customer acknowledges and agrees that any warranties included herein do not extend or apply to Returns: No stock items may be returned without prior written authorization. Request to return stock items must be made within sixty (60) days of purchase and must include our original invoice number. The returned goods must be new, in original undamaged packaging, and are subject to inspection. Returned goods are subject to a twenty-five percent (25%) restocking fee. Items other than shown in this catalog are special order items and are not returnable and cannot be cancelled once order is placed. Customer will be invoiced for special order items left in our warehouse beyond thirty (30) calendar days. Notice of Claim: No action by customer shall be brought at any time against unless written notice of any claim alleged to exist is delivered by customer to an officer of Elite Air Systems Inc. within sixty (60) calendar days after the event complained of first becomes known or should have become known to customer, whichever is earlier. Limitation of Liability: Elite Air Systems, Inc's liability in all events is limited to, and shall not exceed, the purchase price paid. Except as set forth herein, Elite Air Systems, Inc. shall not be liable for any loss or damages, direct, indirect, incidental or consequential. Jurisdiction: Customer hereby waives trial by jury and the right thereto in any action proceeding, arising out of, under or by reason of purchase from Elite Air System, Inc. Customer's contractual relationship with Elite Air Systems, Inc. constitutes and agreement made in Pennsylvania, New Jersey & Delaware and is governed by the laws of Pennsylvania. At Elite Air Systems, Inc's election, any action arising from such agreement may be litigated in Pennsylvania, and customer by purchasing from consents to the jurisdiction and venue of any local, state. Or federal court located in Pennsylvania. 41

44 Driving Directions From South Jersey: Take either the Tacony, Ben Franklin or Walt Whitman Bridge to I-95 North. Take I-95 North to the Street Road exit (PA-132) and take Street Road West approximately 8 miles. At Jacksonville Road make a left (PA-332) and continue.6 miles. At Bon-Air Drive make a right and then a quick left on Ash Circle. From Delaware: Take I95 North to the Street Road exit (PA-132) and take Street Road West approximately 8 miles. At Jacksonville Road make a left (PA-332) and continue.6 miles. At Bon-Air Drive make a right and then a quick left on Ash Circle. From Pennsylvania Turnpike: Take the Turnpike to the Willow Grove Exit (# 343). Take Route # 611 North to County Line Road and make a right. Take County Line Road approximately 4 miles and make a left on Jacksonville Road (PA-332) and continue for.2 miles. At Bon-Air Drive make a left and then a quick left on Ash Circle. From Philadelphia: Take I95 North to the Street Road exit (PA-132) and take Street Road West approximately 8 miles. At Jacksonville Road make a left (PA-332) and continue.6 miles. At Bon-Air Drive make a right and then a quick left on Ash Circle. Who to Contact at 57 Ash Circle Warminster, PA Ph: (215) Fx: (215) Hours (weekdays) 7:30 5:00 Owners Ext Address Customer Support Ext Address Bill Ulmer 230 bulmer@eliteairsys.com Dee Roth 221 droth@eliteairsys.com Larry O'Donnell 222 lodonnell@eliteairsys.com Jim Longstreth, Jr. 223 jlongstreth@eliteairsys.com Sales Engineers Air Distribution Mark Bartlett 224 mbartlett@eliteairsys.com Bruce Miller - Mgr. 233 bmiller@eliteairsys.com Dave Ulmer 226 dulmer@eliteairsys.com Cathy Colletta 232 ccolletta@eliteairsys.com Joe Reaney 227 jreaney@eliteairsys.com Jamie Lynskey 234 jlynskey@eliteairsys.com Randy Salvati 225 rsalvati@eliteairsys.com Andy Herrera 238 aherrera@eliteairsys.com Accounting Stanley Brachowski 223 stanley@eliteairsys.com Maggie Wilson 229 mmangino@eliteairsys.com Mike Mulholland 228 mulholland@eliteairsys.com Warehouse Manager Jim Longstreth, Sr.

Inline and Roof Mounted Fans

Inline and Roof Mounted Fans CV Inline and Roof Mounted Fans Page Introduction........................................... 2 Construction Features................................. 3-4 Specifications and Dimension Data CVD (Direct Drive

More information

Square Inline Fans with Multi-Directional Discharge

Square Inline Fans with Multi-Directional Discharge SQN Square Inline Fans with Multi-Directional Discharge Page Introduction............................................2 Standard Construction Features............................ 3 Specifications and Dimension

More information

Filtered Kitchen Supply Packaged Ventilator

Filtered Kitchen Supply Packaged Ventilator Filtered Kitchen Supply Packaged Ventilator Page Introduction........................................... 2 Information............................................ 3 Specifications and Dimension Data KD................................................

More information

Ceiling and Inline Fans

Ceiling and Inline Fans Ceiling and Inline Fans Page Introduction.....................................2 Construction Features..............................3 Specifications and Dimension Data GC 122-184....................................4

More information

Tamper Proof Downblast Centrifugal Exhaust Ventilators Page

Tamper Proof Downblast Centrifugal Exhaust Ventilators Page SRSH Tamper Proof Downblast Centrifugal Exhaust Ventilators Page Introduction....................................... 2 SRSH-D Specifications and Dimension Data............. 3 SRSH-B Specifications and

More information

Power Roof and Wall Ventilators

Power Roof and Wall Ventilators Loren Cook Company is proud to be the world leader of industrial and commercial fans and blowers. With a commitment of over 6 years, Loren Cook Company believes in superior quality and phenomenal service.

More information

Centrifugal Filtered Supply Roof Blowers

Centrifugal Filtered Supply Roof Blowers CFS Centrifugal Filtered Supply Roof Blowers Page Introduction...................................... 2 Specifications and Dimension Data................... 3 Typical Installation................................

More information

Fixed Pitch Vane Axial Fan

Fixed Pitch Vane Axial Fan Fixed Pitch Vane Axial Fan Page Introduction...........................................2 Construction Features...................................3 Mounting Options.......................................3

More information

Tube Axial Fan Page Specifications & Dimension Data Performance Data

Tube Axial Fan Page Specifications & Dimension Data Performance Data Tube Axial Fan Page Introduction........................................... 2 Construction Features................................... 3 Information........................................... 4 Specifications

More information

Tubular Centrifugal Inline Fans Page Introduction... 2 Construction Features... 3 Specification and Dimension Data TCN-D (Inline Fan- Direct

Tubular Centrifugal Inline Fans Page Introduction... 2 Construction Features... 3 Specification and Dimension Data TCN-D (Inline Fan- Direct Tubular Centrifugal Inline Fans Page Introduction........................................... 2 Construction Features.................................. 3 Specification and Dimension Data TCN-D (Inline Fan-

More information

Industry best 5 year fan housing warranty, 1 year motor warranty

Industry best 5 year fan housing warranty, 1 year motor warranty MODELS & e DIRECT DRIVE CENTRIFUGAL DOWNBLAST ROOF EXHAUSTERS MODEL - DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTER MODEL FEATURES Exhaust air up to 4,980 CFM in high static pressure applications up to 1-1/2

More information

Mixed-Flow Blowers Page Specifications and Dimension Data Performance Data Sound Data

Mixed-Flow Blowers Page Specifications and Dimension Data Performance Data Sound Data Mixed-Flow Blowers Page Introduction.......................................... 2-4 Standard Construction Features.......................... 5-7 Mixed-Flow Advantages.................................. 8

More information

MODELS STXD & STXDe DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTERS

MODELS STXD & STXDe DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTERS MODELS & e DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTERS MODEL DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTER MODEL FEATURES Exhaust air up to 4,780 CFM in high static pressure applications up to 1-1/2 w.g. Attractive

More information

Centrifugal Spun Aluminum Products

Centrifugal Spun Aluminum Products Centrifugal Spun Aluminum Products SDB SDBD STXB STXD Downblast & Upblast Centrifugal Roof Wall Exhausters Designed with Efficiency in Mind CSAP_0415 April 2015 Centrifugal Spun Aluminum Line Overview

More information

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Models VUDK and VUBK

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Models VUDK and VUBK CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Models VUDK and VUBK CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Direct and Belt Driven Models VUDK and VUBK DESIGNED AND ENGINEERED TO MEET INDUSTRY NEEDS The Carnes Company

More information

TURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS. Model TCPE

TURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS. Model TCPE TURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS Model TCPE CATALOG 4800 February 2017 PANEL FANS Overview TCPE TCPE panel fans are direct drive panel fans designed for low static pressures.

More information

TURNING AIR INTO SOLUTIONS. LOW PROFILE UPBLAST PROPELLER ROOF VENTILATORS. LUD/LUB (Standard) LUBMO (Motor Out of Airstream) LUBSH (UL Smoke & Heat)

TURNING AIR INTO SOLUTIONS. LOW PROFILE UPBLAST PROPELLER ROOF VENTILATORS. LUD/LUB (Standard) LUBMO (Motor Out of Airstream) LUBSH (UL Smoke & Heat) TURNING AIR INTO SOLUTIONS. LOW PROFILE UPBLAST ROOF VENTILATORS LUD/LUB (Standard) LUBMO (Motor Out of Airstream) LUBSH (UL Smoke & Heat) CATALOG 4870 April 17 ROOF VENTILATORS Overview Propeller Roof

More information

Industry best 5 year fan housing warranty, 1 year motor warranty

Industry best 5 year fan housing warranty, 1 year motor warranty MEL FEATURES Exhaust air up to 28,000 CFM in high static pressure applications up to 1-1/4 w.g. Attractive spun aluminum exterior Belt drives permit easy performance adjustments when needed Non-overloading

More information

CENTRIFUGAL WALL EXHAUSTERS Models VWDK and VWBK

CENTRIFUGAL WALL EXHAUSTERS Models VWDK and VWBK CENTRIFUGAL WALL EXHAUSTERS Models VWDK and VWBK CENTRIFUGAL WALL EXHAUSTERS Direct and Belt Driven Models VWDK and VWBK DESIGNED AND ENGINEERED TO MEET INDUSTRY NEEDS The Carnes Company centrifugal wall

More information

LORENIZED Fan Finish. The COOK Powder Coating Process. Free design tools. Culture of Quality. Independent Certification. Download

LORENIZED Fan Finish. The COOK Powder Coating Process. Free design tools. Culture of Quality. Independent Certification. Download CV Culture of Quality Free design tools Loren Cook Company is proud to be a leader in the design and manufacturing of fans, blowers, gravity ventilators, lab exhaust systems and energy recovery equipment.

More information

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER MEL TXD Model Features Exhaust air up to 3,400 CFM in high static pressure applications up to 1-1/4 w.g. Attractive spun aluminum exterior Direct drive units have low sound levels and quiet operation Non-overloading

More information

Roof Upblast and Sidewall Exhaust

Roof Upblast and Sidewall Exhaust XRUB, XRUD, XSEB, XSED, and XRUBS models are listed for electrical (UL/C-UL US 705) File no. E40001 and for grease removal (UL/C-UL US 762) File no. MH11745. Accurex, LLC certifies model XRUB, XRUD, XSEB,

More information

EcoWatt Products. Advancing Ventilation

EcoWatt Products. Advancing Ventilation EcoWatt Products Advancing Ventilation EcoWatt-0817 August 2017 What is EcoWatt At S&P we strive to engineer and manufacture the most efficient products in the market. In order to categorize our most energy

More information

Twin City Fan & Blower

Twin City Fan & Blower Twin City Fan & Blower BULLETIN 4810 August 2005 PROPELLER WALL S DIRECT AND BELT DRIVE TYPE WPMD/WPMB WPMD/WPMB Propeller Wall Fans Twin City Fan & Blower WPMD and WPMB Medium Duty Propeller Wall Fans

More information

Industry best 5 year fan housing warranty, 1 year motor warranty

Industry best 5 year fan housing warranty, 1 year motor warranty MODEL RED MODEL FEATURES Exhaust air up to 3,000 CFM in high static pressure applications up to 1 w.g. Attractive spun aluminum exterior Direct drive units have low sound levels and quiet operation Non-overloading

More information

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER MEL TXD MEL FEATURES Exhaust air up to 3,400 CFM in high static pressure applications up to 1-1/4 w.g. Attractive spun aluminum exterior Direct drive units have low sound levels and quiet operation Non-overloading

More information

Centrifugal Spun Aluminum Products

Centrifugal Spun Aluminum Products Centrifugal Spun Aluminum Products SDB SDBD STXB STXD Downblast & Upblast Centrifugal Roof Wall Exhausters Designed with Efficiency in Mind CSAP_0116 January 2016 Centrifugal Spun Aluminum Line Overview

More information

MODEL FF/FFC CEILING AND INLINE/CABINET VENTILATORS

MODEL FF/FFC CEILING AND INLINE/CABINET VENTILATORS R MODEL FF/FFC CEILING AND INLINE/CABINET VENTILATORS APPLICATION The extremely quiet FF and FFC ventilators are used to exhaust air from a variety of commercial and institutional applications, such as

More information

Centrifugal Spun Aluminum Products

Centrifugal Spun Aluminum Products Centrifugal Spun Aluminum Products SDB SDBD STXB STXD Downblast & Upblast Centrifugal Roof Wall Exhausters Designed with Efficiency in Mind CSAP_0317 March 2017 Centrifugal Spun Aluminum Line Overview

More information

K SERIES DIRECT DRIVE SIDEWALL PROPELLER FANS

K SERIES DIRECT DRIVE SIDEWALL PROPELLER FANS K Series Direct Drive K SERIES DIRECT DRIVE SIDEWALL PROPELLER FANS SPECIFICATIONS Fans shall be direct drive propeller type with integral motorside OSHA style guard. Propeller construction shall be of

More information

TURNING AIR INTO SOLUTIONS. CENTRIFUGAL ROOFTOP EXHAUST FANS LOW PROFILE HOODED & LOUVERED DCLH BCLH DCLP BCLP

TURNING AIR INTO SOLUTIONS. CENTRIFUGAL ROOFTOP EXHAUST FANS LOW PROFILE HOODED & LOUVERED DCLH BCLH DCLP BCLP TURNING AIR INTO SOLUTIONS. CENTRIFUGAL ROOFTOP EXHAUST FANS LOW PROFILE HOODED & LOUVERED DCLH BCLH DCLP BCLP CATALOG 4135 February 2017 PENTHOUSE ROOF VENTILATORS Overview DCLH I BCLH I DCLP I BCLP Model

More information

INLINE CENTRIFUGAL DUCT FANS Direct and Belt Driven Models ZIDK and ZIBK

INLINE CENTRIFUGAL DUCT FANS Direct and Belt Driven Models ZIDK and ZIBK INLINE CENTRIFUGAL DUCT FANS Direct and Belt Driven Models ZIDK and ZIBK DESIGNED AND ENGINEERED TO MEET INDUSTRY NEEDS Air Zoë Centrifugal Inline Duct fans have been developed to efficiently handle the

More information

The Industrial Choice. Model SCDD Direct Drive. Model SCBD Belt Driven SQUARE INLINE FANS. Direct Drive & Belt Driven Model SCDD / SCBD

The Industrial Choice. Model SCDD Direct Drive. Model SCBD Belt Driven SQUARE INLINE FANS. Direct Drive & Belt Driven Model SCDD / SCBD The Industrial Choice. Model SCDD Direct Drive Model SCBD Belt Driven SQUARE INLINE FANS Direct Drive & Belt Driven Model SCDD / SCBD BULLETIN 40 January 007 Square Inline Centrifugal Fans General Information

More information

MODELS FF & FFC CEILING AND INLINE/CABINET VENTILATORS

MODELS FF & FFC CEILING AND INLINE/CABINET VENTILATORS Model FF Model FFC Model ff Features Exhaust air up to 1500 CFM Forward curve centrifugal wheel for high static pressure capabilities to 1 w.g. Resilient mount, low RPM motor for quiet operation (except

More information

MODEL FF/FFC CEILING AND INLINE/CABINET VENTILATORS

MODEL FF/FFC CEILING AND INLINE/CABINET VENTILATORS MODEL FF/FFC CEILING AND INLINE/CABINET VENTILATORS APPLICATION The extremely quiet FF and FFC ventilators are used to exhaust air from a variety of commercial and institutional applications, such as restrooms,

More information

MODELS UBB & UBX UPBLAST PROPELLER ROOF EXHAUSTERS BELT AND DIRECT DRIVE

MODELS UBB & UBX UPBLAST PROPELLER ROOF EXHAUSTERS BELT AND DIRECT DRIVE BELT AND DIRECT DRIVE MODEL FEATURES Exhaust air up to 78,000 CFM in static pressure applications up to 1/2 w.g. Straight-through air flow design results in maximum exhaust efficiency Belt drives permit

More information

TURNING AIR INTO SOLUTIONS. LOW PROFILE HOODED PROPELLER ROOF VENTILATORS. LHD/LHB (Exhaust/Supply) LHDF/LHBF (Filtered Supply)

TURNING AIR INTO SOLUTIONS. LOW PROFILE HOODED PROPELLER ROOF VENTILATORS. LHD/LHB (Exhaust/Supply) LHDF/LHBF (Filtered Supply) TURNING AIR INTO SOLUTIONS. LOW PROFILE HOODED ROOF VENTILATORS LHD/LHB (Exhaust/Supply) LHDF/LHBF (Filtered Supply) CATALOG 4860 April 17 ROOF VENTILATORS Overview Propeller Roof Ventilators LHB with

More information

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK CENTRIFUGAL UPBLAST ROOF EXHAUSTERS COMMERCIAL KITCHEN APPLICATIONS Belt Driven Model VRBK DESIGNED AND ENGINEERED TO MEET INDUSTRY NEEDS The Carnes Company

More information

Centrifugal Exhaust Fans Series C. Roof Upblast and Sidewall

Centrifugal Exhaust Fans Series C. Roof Upblast and Sidewall Centrifugal Exhaust s Series C Roof Upblast and Sidewall April 28 Series C - Spun Aluminum Roof Upblast and Sidewall Centrifugal Exhaust s When you buy a Greenheck Series C model, you receive a fan with

More information

CEILING & INLINE/CABINET VENTILATORS

CEILING & INLINE/CABINET VENTILATORS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS CEILING & INLINE/CABINET VENTILATORS T-Series TL-Series CATALOG 4600 MARCH 2018 CEILING & INLINE VENTILATORS OVERVIEW T I TL T-Series

More information

SQUARE INLINE CENTRIFUGAL FANS

SQUARE INLINE CENTRIFUGAL FANS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS SQUARE INLINE CENTRIFUGAL FANS DSI BSI CATALOG 40 FEBRUARY 07 SQUARE INLINE CENTRIFUGAL FANS Overview DSI BSI Twin City Fan & Blower

More information

MODELS FF & FFC CEILING AND INLINE/CABINET VENTILATORS

MODELS FF & FFC CEILING AND INLINE/CABINET VENTILATORS Model FF Model FFC MODEL FF FEATURES Exhaust air up to 1500 CFM Forward curve centrifugal wheel for high static pressure capabilities to 1 w.g. Resilient mount, low RPM motor for quiet operation Speed

More information

A Fläkt Woods Company. Model PFB Panel Exhaust Fans 24" 72" Diameter Bulletin PF-1410 July 2003

A Fläkt Woods Company. Model PFB Panel Exhaust Fans 24 72 Diameter Bulletin PF-1410 July 2003 A Fläkt Woods Company PFB Panel Exhaust Fans 24" 72" Diameter Bulletin PF-1410 July 2003 Fläkt Woods Group Creative Air Fläkt Woods was created by bringing together several of the worlds leading players

More information

Sidewall Propeller Fans Direct Drive. Exhaust / Supply

Sidewall Propeller Fans Direct Drive. Exhaust / Supply Sidewall Propeller Fans Direct Drive / February 2009 Sidewall Propeller Fans Greenheck s sidewall propeller fan line is the ideal choice for factory and warehouse applications where high volumes of air

More information

2018 STOCK CATALOG. Sales Offices. Serving Upstate New York, Vermont & Western Massachusetts with Quality HVAC Products for over 50 Years

2018 STOCK CATALOG. Sales Offices. Serving Upstate New York, Vermont & Western Massachusetts with Quality HVAC Products for over 50 Years Serving Upstate New York, Vermont & Western Massachusetts with Quality HVAC Products for over 50 Years 2018 STOCK CATALOG Sales Offices ALBANY, NEW YORK BUFFALO, NEW YORK ROCHESTER, NEW YORK SYRACUSE,

More information

TURNING AIR INTO SOLUTIONS. CEILING & INLINE/CABINET VENTILATORS. T-Series TL-Series

TURNING AIR INTO SOLUTIONS. CEILING & INLINE/CABINET VENTILATORS. T-Series TL-Series TURNING AIR INTO SOLUTIONS. CEILING & INLINE/CABINET VENTILATORS T-Series TL-Series CATALOG 4600 March 2018 CEILING & INLINE VENTILATORS Overview T I TL Twin City Fan & Blower s T-Series Ceiling and TL-Series

More information

Restaurant Exhaust Ventilator

Restaurant Exhaust Ventilator Restaurant Exhaust Ventilator Page Introduction........................................... 2 Construction Features................................... 3 Specifications & Dimension Data VCRD / VCRD-HP /

More information

FILTERED AIR SUPPLY FANS. Direct Drive & Belt Driven Models FSR / FSWD / FSWB / FF. Model FSWB Wall Mounted. Model FSR Roof Mounted

FILTERED AIR SUPPLY FANS. Direct Drive & Belt Driven Models FSR / FSWD / FSWB / FF. Model FSWB Wall Mounted. Model FSR Roof Mounted The Industrial Choice. Model FSWB Wall Mounted Model FSR Roof Mounted FILTERED AIR SUPPLY FANS Direct Drive & Belt Driven Models FSR / FSWD / FSWB / FF CATALOG 664 June 2013 Filtered Air Supply Fans Roof

More information

TU-WAY ROOF VENTILATORS

TU-WAY ROOF VENTILATORS BULLETIN 615 December 2000 TU-WAY ROOF VENTILATORS Tu-WAY Roof Ventilators Aerovent has provided quality air moving and ventilation equipment for over sixty-five years and is a recognized leader in this

More information

SECTION HVAC POWER VENTILATORS

SECTION HVAC POWER VENTILATORS SECTION 233423 HVAC POWER VENTILATORS 1. PART 1 GENERAL 1.1. RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Twin City Fan & Blower

Twin City Fan & Blower Twin City Fan & Blower BULLETIN 405 April 2009 UPBLAST ROOF, WALL, & KITCHEN EXHAUSTERS TYPE DCRU / DCRUR / DCRW / DCRWR TYPE BCRU / BCRUR / BCRW / BCRWR TYPE BCRUSH (Smoke & Heat) Upblast Roof, Wall,

More information

The Industrial Choice. PROPELLER WALL FANS DIRECT DRIVE & BELT DRIVEN. Models BSDDP / BSBP

The Industrial Choice. PROPELLER WALL FANS DIRECT DRIVE & BELT DRIVEN. Models BSDDP / BSBP The Industrial Choice. WALL S DIRECT DRIVE & BELT DRIVEN Models BSDDP / BSBP CATALOG 172 June 15 Propeller Wall Fans Models BSDDP BSBP Aerovent BSDDP and BSBP Propeller Wall Fans are specifically designed

More information

SECTION AXIAL HVAC FANS

SECTION AXIAL HVAC FANS SECTION 233413 - AXIAL HVAC FANS 1. PART 1 GENERAL 1.1. RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Propeller Hooded Roof Fans

Propeller Hooded Roof Fans Propeller Hooded Roof Fans Series A - Model AE and AS Exhaust and Supply Fans August 8 Model AE and AS Propeller Fans Greenheck s models AE (axial exhaust) and AS (axial supply) spun aluminum direct drive

More information

SPUN ALUMINUM POWER ROOF AND WALL VENTILATORS

SPUN ALUMINUM POWER ROOF AND WALL VENTILATORS BULLETIN 0 January 007 SPUN ALUMINUM POWER ROOF AND WALL VENTILATORS TYPE ACX / ACXD TYPE ATD / ATDR / ATDW / ATDWR TYPE ATB / ATBR / AWX / AWXR Model ACX Model ATB Model ACXD Model ATDR Model AWX Centrifugal

More information

The Industrial Choice. Model BSHD Direct Drive LOW PROFILE HOODED PROPELLER ROOF VENTILATORS. Models BSHD / BSHB

The Industrial Choice. Model BSHD Direct Drive LOW PROFILE HOODED PROPELLER ROOF VENTILATORS. Models BSHD / BSHB The Industrial Choice. Model BSHD Direct Drive LOW PROFILE HOODED ROOF VENTILATORS Models BSHD / BSHB CATALOG 632 November 12 Hooded Roof Ventilators Models BSHD BSHB Aerovent Low Profile Hooded Roof Ventilators

More information

MODELS HRSB & HRSD HOODED PROPELLER ROOF SUPPLY FANS

MODELS HRSB & HRSD HOODED PROPELLER ROOF SUPPLY FANS MODEL FEATURES Supply air to over 56,000 CFM up to 3/4 w.g. Belt drives permit easy performance adjustments when needed Direct drive units have low sound levels and quiet operation. Filtered models available

More information

forward curved inline duct blowers

forward curved inline duct blowers Defining Innovation. forward curved inline duct blowers TYPE DBS (Single) DBT (Twin) BULLETIN 4220 January 2011 Duct Blowers General Information Twin City Fan s belt driven DBS (single) and DBT (twin)

More information

Roof Upblast and Sidewall Exhaust

Roof Upblast and Sidewall Exhaust XRUB, XRUD, XSEB, XSED, and XRUBS models are listed for electrical (UL/C-UL US 0) File no. E000 and for grease removal (UL/C-UL US ) File no. MH. Accurex, LLC certifies model XRUB, XRUD, XSEB, XSED, and

More information

Downblast Centrifugal Fans with ECM

Downblast Centrifugal Fans with ECM Downblast Centrifugal Fans with ECM Model ered Featuring Electronically Commutated Motors GC_eRED_0512 May 2012 1 Motor Up to 90% efficient, electronically commutated motor (ECM) DOWNBLAST CENTRIFUGAL

More information

COOK. Gravity Ventilation

COOK. Gravity Ventilation COOK Gravity Ventilation Gravity Vents Page Introduction........................................ 2-3 Gravity Ventilation................................... 4-5 Mechanical Ventilation..................................

More information

MODELS HREB-C & HRED-C HOODED PROPELLER ROOF EXHAUST FANS

MODELS HREB-C & HRED-C HOODED PROPELLER ROOF EXHAUST FANS MODEL FEATURES Exhaust air to over 40,000 CFM up to 3/4 w.g. Belt drives permit easy performance adjustments when needed Direct drive units have low sound levels and quiet operation. Reversible blades

More information

ceiling & inline/cabinet ventilators

ceiling & inline/cabinet ventilators Air Moving Solutions. ceiling & inline/cabinet ventilators T-Series ( T TL ) CATALOG 4600 March 2012 Ceiling&InlineVentilators T-Series T TL Twin City Fan & Blower s T Series Ceiling and TL Series Inline/Cabinet

More information

BELT DRIVEN CENTRIFUGAL ROOFTOP FILTERED SUPPLY FAN

BELT DRIVEN CENTRIFUGAL ROOFTOP FILTERED SUPPLY FAN Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS BELT DRIVEN CENTRIFUGAL ROOFTOP FILTERED SUPPLY FAN MODEL BCRFS CATALOG 4310 JUNE 2012 FILTERED SUPPLY VENTILATORS Model BCRFS Twin City

More information

Twin City Fan & Blower

Twin City Fan & Blower Twin City Fan & Blower BULLETIN 4050 November 2009 DOWNBLAST ROOF EXHAUSTERS TYPE DCRD / BCRD (Spun Aluminum Housing) TYPE BCRD-E (Endurex Polymeric Housing) Downblast Roof Exhausters Twin City Fan & Blower

More information

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VQBL

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VQBL CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VQBL CENTRIFUGAL UPBLAST ROOF EXHAUSTERS HIGH TEMPERATURE SMOKE EXHAUST APPLICATIONS Belt Driven Model VQBL DESIGNED AND ENGINEERED TO MEET INDUSTRY NEEDS SECTION

More information

Low Silhouette Power Roof Ventilator Propeller

Low Silhouette Power Roof Ventilator Propeller LOW SILHOUETTE Models LT, LG and LF Power Roof Ventilator Propeller Contemporary Styling Carnes line of low silhouette power roof ventilators are ideal for installations requiring high performance and

More information

DESIGN GUIDELINES FANS PAGE 1 of 7

DESIGN GUIDELINES FANS PAGE 1 of 7 DESIGN GUIDELINES FANS PAGE 1 of 7 1.1. REFERENCE STANDARDS 1.1.1. Publications listed below (including amendments, addenda, revisions, supplements and errata) form a part of this specification to the

More information

Advancing Ventilation

Advancing Ventilation Centrifugal oof Sidewall LPD CWD STXD STXDe SDBD SDBDe SDB STXB Direct Drive Belt Drive Centrifugal oof Sidewall Fans Advancing Ventilation centrifugal-roof--sidewall-0219 February 2019 MODEL LPD LOW POFILE

More information

Tubular Centrifugal Fans

Tubular Centrifugal Fans Tubular Centrifugal Fans Model TCB Inline - Horizontal or Vertical Roof Upblast and Roof Supply March 2007 Tubular Centrifugal Fans The TCB series of inline centrifugal fans is designed for ducted inline,

More information

VANEAXIAL FANS. DUCT FANS Capacities to 60,000 CFM Static pressures to 2 WG. TUBEAXIAL FANS Capacities to 86,000 CFM Static pressures to 3 WG

VANEAXIAL FANS. DUCT FANS Capacities to 60,000 CFM Static pressures to 2 WG. TUBEAXIAL FANS Capacities to 86,000 CFM Static pressures to 3 WG BULLETIN 671 AUGUST, 2016 VANEAXIAL FANS DUCT FANS Capacities to 60,000 Static pressures to 2 WG TUBEAXIAL FANS Capacities to 86,000 Static pressures to 3 WG Capacities to 0,000 Static pressures to 5 WG

More information

The Industrial Choice. Model VB Direct Drive. Model VBBD Belt Driven VANEAXIAL FANS. Direct Drive & Belt Driven Model VB / VBBD

The Industrial Choice. Model VB Direct Drive. Model VBBD Belt Driven VANEAXIAL FANS. Direct Drive & Belt Driven Model VB / VBBD The Industrial Choice. Model VB Direct Drive Model VBBD Belt Driven VANEAXIAL FANS Direct Drive & Belt Driven Model VB / VBBD BULLETIN 466 November 2000 Contents Construction Features Belt Driven... 3

More information

FILTERED AIR SUPPLY FANS

FILTERED AIR SUPPLY FANS BULLETIN 664-B September 2004 FILTERED AIR SUPPLY FANS Wall Mounted Roof Mounted Catalog Numbering System To identify a specific fan for ordering or engineering specification, it is necessary to show

More information

Inline Fans [ 14 ] * UL is optional and must be specified.

Inline Fans [ 14 ] * UL is optional and must be specified. XTIF, XIB and XID models are listed for electrical (UL/C-UL US 705) File no. E40001. Model XTIF is available with the UL 762 Listing (Power Ventilators for Restaurant Exhaust Appliances). Accurex, LLC

More information

Propeller Upblast Roof Fans

Propeller Upblast Roof Fans Propeller Upblast Roof Fans Models RBU, RBUMO, RDU and RGU Direct Drive, Belt Drive and Gravity April 2010 Propeller Upblast Roof Fans Greenheck upblast propeller fans are designed to discharge contaminants

More information

MODEL KSF BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN

MODEL KSF BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN R MODEL BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN APPLICATION s fans are primarily used for filtered make-up air in kitchen hood applications but may also be specified for make-up air in commercial

More information

AMCA Seal Assures rating of Sound and Air performance. 2 year fan housing warranty, 1 year motor warranty

AMCA Seal Assures rating of Sound and Air performance. 2 year fan housing warranty, 1 year motor warranty MODEL FEATURES Exhaust air up to 2,800 CFM in high static pressure applications up to 1 w.g. Direct drive units have low sound levels and quiet operation Ideal for applications where space is limited Non-overloading

More information

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER MODEL MODEL FEATURES Exhaust air up to 60,116 CFM in static pressure applications up to 1 w.g. Straight-through air flow design results in maximum exhaust efficiency Motor and drives are located outside

More information

EXHAUST FANS CUD & CUB UPBLAST FANS

EXHAUST FANS CUD & CUB UPBLAST FANS EXHAUST FANS CUD & CUB UPBLAST FANS Suitable for roof or wall mount Backward inclined, non overloading wheels Spun aluminum housing Blades & inlets fabricated from aluminum Easy access to motor compartment

More information

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved Centrifugal Roof Supply Fans Models and Forward Curved B U I L D I N G V A L U E I N A I R. April 2008 Centrifugal Filtered Roof Supply Fan When you buy a Greenheck model or, you receive a fan with the

More information

DIrect drive exhaust & supply panel fans

DIrect drive exhaust & supply panel fans Air Moving Solutions. DIrect drive exhaust & supply panel fans MODEL BULLETIN 4800 March 2012 Direct DrivePanel ans Model panel fans are direct drive panel fans designed for low static pressures. They

More information

Centrifugal Upblast Power Roof Ventilators

Centrifugal Upblast Power Roof Ventilators INDUSTRIES AMERICAN COOLAIR CORPORATION Centrifugal Upblast Power Roof Ventilators TYPE UBCA - BELT DRIVE TYPE UDCA - DIRECT DRIVE TABLE OF CONTENTS UBCA Sizes 06 to 44 Flow rates from 229 to 29,002 CFM

More information

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved Centrifugal Roof Supply Fans Models and Forward Curved April 2008 Centrifugal Filtered Roof Supply Fan When you buy a Greenheck model or, you receive a fan with the industry s best performance and durability

More information

OSU PROJECT NO PAGE 1 02 NOV 2006 SECTION DUCTWORK ACCESSORIES

OSU PROJECT NO PAGE 1 02 NOV 2006 SECTION DUCTWORK ACCESSORIES OSU PROJECT NO. 30-04-15 PAGE 1 PART 1 GENERAL 1.1 WORK INCLUDED A. Medium and low pressure duct accessories, sealants and tapes, flexible connectors, fire dampers, smoke dampers, combination smoke and

More information

BULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven

BULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven BULLETIN 456 July 1997 VANEAXIAL FANS Type W Direct Drive/Belt Driven Model VW Direct Drive Model VWBD Belt Driven Aerovent certifies that the Type W Vaneaxial Fans shown herein are licensed to bear the

More information

Centrifugal Inline Fans Models SQ and BSQ Direct and Belt Drive

Centrifugal Inline Fans Models SQ and BSQ Direct and Belt Drive Centrifugal Inline s Models SQ and BSQ Direct and Belt Drive May 21 Models SQ and BSQ Centrifugal Square Inline Duct s Table of Contents Standard Construction Features...4-5 Vari-Green Motor & Control

More information

Tube Axial Inline Fans

Tube Axial Inline Fans Tube Axial Inline Fans Models TDI & TBI-CA Level 3 with Cast Aluminum Propeller Direct & Belt Drive Clean Air or Fume Exhaust July 2011 Features Tube Axial Inline Fans Greenheck s tube axial fans are the

More information

MODEL FF50 CEILING FAN

MODEL FF50 CEILING FAN MODEL FF50 CEILING FAN SPECIFICATION SHEET Simple installation dependability make this odor moisture removing fan a real value. Matte white polymeric blends well with any decor Torsion spring grill mounting

More information

MODELS CSF & LSF BELT DRIVE CENTRIFUGAL FILTERED SUPPLY FANS

MODELS CSF & LSF BELT DRIVE CENTRIFUGAL FILTERED SUPPLY FANS S CSF & LSF Model CSF Hooded Design FEATURES Supply air to over 13,000 CFM in static pressure capabilities to 2 w.g. Heavy-galvanized construction Belt drives permit easy performance adjustments when needed

More information

FILTERED SUPPLY CENTRIFUGAL Belt Drive

FILTERED SUPPLY CENTRIFUGAL Belt Drive FILTERED SUPPLY CENTRIFUGAL Belt Drive FILTERED SUPPLY CENTRIFUGAL - BELT DRIVE SECTION 9 Carnes Models VSBB and VHBB centrifugal filtered roof supply fans are available in six sizes - 8 through 20 with

More information

Centrifugal Inline Fans Models SQ-M and BSQ-M. Direct and Belt Drive

Centrifugal Inline Fans Models SQ-M and BSQ-M. Direct and Belt Drive Centrifugal Inline s Models SQ-M and BSQ-M Direct and Belt Drive July 2010 Centrifugal Inline Duct s Greenheck's model SQ-M and BSQ-M centrifugal square inline fans feature a unique combination of installation

More information

Safety disconnect. switch is optional. Belt drive with adjustable motor pulley provides flexibility to match operating requirements.

Safety disconnect. switch is optional. Belt drive with adjustable motor pulley provides flexibility to match operating requirements. CWBA Sizes 12 to 20 711 to 5709 CFM Static Pressure to 2 AMCA Licensed Ratings for Sound and Air CWDA Sizes 06 to 20 133 to 4942 CFM Static Pressure to 1 AMCA Licensed Ratings for Sound and Air Safety

More information

The Industrial Choice. Model BD40C UPBLAST AXIAL ROOF VENTILATORS. Macheta Airfoil Design. Model BD40C

The Industrial Choice. Model BD40C UPBLAST AXIAL ROOF VENTILATORS. Macheta Airfoil Design. Model BD40C The Industrial Choice. Model BD40C UPBLAST AXIAL ROOF VENTILATORS Macheta Airfoil Design Model BD40C BULLETIN 616 July 1997 Upblast Axial Model BD40C Roof Ventilators The Model BD40C is the most versatile

More information

Need a. Bathroom Fan?

Need a. Bathroom Fan? Need a Bathroom Fan? ASX CEILING FANS Features ASX VCDD and VCDK Ceiling Ventilators have been designed to give quality conscious architects, design engineers, builders and specifiers the ultimate in heavy

More information

TURNING AIR INTO SOLUTIONS. UPBLAST ROOF, WALL & KITCHEN EXHAUSTERS DCRU DCRUR DCRW DCRWR BCRU BCRUR BCRW BCRWR BCRUSH

TURNING AIR INTO SOLUTIONS. UPBLAST ROOF, WALL & KITCHEN EXHAUSTERS DCRU DCRUR DCRW DCRWR BCRU BCRUR BCRW BCRWR BCRUSH TURNING AIR INTO SOLUTIONS. UPBLAST ROOF, WALL & KITCHEN EXHAUSTERS DCRU DCRUR DCRW DCRWR BCRU BCRUR BCRW BCRWR BCRUSH CATALOG 405 February 207 ROOF & WALL EXHAUSTERS Overview Roof & Wall Exhausters Twin

More information

INDUSTRIES AMERICAN COOLAIR CORPORATION. Centrifugal Filtered Supply Roof Ventilators TYPE CFS - TYPE SIS

INDUSTRIES AMERICAN COOLAIR CORPORATION. Centrifugal Filtered Supply Roof Ventilators TYPE CFS - TYPE SIS INDUSTRIES AMERICAN COOLAIR CORPORATION Centrifugal Filtered Supply Roof Ventilators TYPE CFS - TYPE SIS CFS Centrifugal Filtered Supply Fans Applications The CFS Centrifugal Filtered supply fans with

More information

Multi-Port Centrifugal Fans for Round Duct

Multi-Port Centrifugal Fans for Round Duct Multi-Port entrifugal Fans for Round when you need to exhaust many points to one VS Series Fantech VS Series ompact, quiet and dependable Multi-unit housing makes incredible demands on ventilation. Fantech

More information

MODEL KSF BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN

MODEL KSF BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN R BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN APPLICATION s fans are primarily used for filtered make-up air in kitchen hood applications but may also be specified for make-up air in commercial and

More information

UPBLAST ROOF, WALL & KITCHEN EXHAUSTERS

UPBLAST ROOF, WALL & KITCHEN EXHAUSTERS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS UPBLAST ROOF, WALL & KITCHEN EXHAUSTERS DCRU DCRUR DCRW DCRWR BCRU BCRUR BCRW BCRWR BCRUSH CATALOG 405 APRIL 08 ROOF & WALL EXHAUSTERS

More information

& 12" 96" / TABD CATALOG

& 12 96 / TABD CATALOG The Industrial Choice. Model TA Direct Drive Model TABD Belt Driven TUBEAXIAL S Macheta Airfoil Design Direct Drive & Belt Driven Sizes 2" through 96" Models TA / TABD CATALOG 5 August 204 Tubeaxial Fans

More information