Air Cooled Single Screw Chiller/ Heat Pump

Size: px
Start display at page:

Download "Air Cooled Single Screw Chiller/ Heat Pump"

Transcription

1 Technical Manual MHS - F Air Cooled Single Screw Chiller/ Heat Pump Models: MCS F MHS F Cooling Capacity: 169kW-1370kW Heating Capacity: 179kW-1439kW Refrigerant: R22/R407C Engineered for flexibility and performance. TM

2 Contents Literature No.: TM-MHS(F)-1401A Supersedes: TM-MHS(F)-1301A Part No.: M Features Features Intelligent Network Controller Single Screw Compressor Nomenclature... 9 Nomenclature (R22, R407C) Accessories Standard accessories (supplied on basic unit) Optional accessories (on request) Safety devices and measures Operation Limits Operation Limits System Water Volume Water flow range Specifications MHS/MCS 050.1FST~MHS/MCS380.2FST[R22 ] MHS/MCS050.1FST~MHS/MCS350.2FST[R407C] MHS/MCS050.1FLN~MHS/MCS350.2FLN[R22] MHS/MCS050.1FLN~MCS350.2FLN[R407C] Correction Capacity Tables Cooling Capacity Tables MHS/MCS050.1FST~MHS/MCS380.2FST[R22] MHS050.1FST~MHS350.2FST[R407C] MHS050.1FLN~MHS350.2FLN[R22] Heating Capacity Table MHS050.1FST2-MHS380.1FST MHS050.1FST4-MHS380.2FST MHS050.1FLN2-MHS380.2FLN MHS050.1FLN4-MHS380.2FLN Pressure Drop Through Evaporator Dimensions MCS050~060 / MHS050~ MCS050~060 / MHS050~ MCS070~080 / MHS070~ MCS100~185 / MHS100~

3 MCS200~380 / MHS200~ MCS100~185 / MHS100~ MCS200~380 / MHS200~ Foundation MCS050~060 / MHS050~ MCS070~080 / MHS070~ MCS100 / MHS MCS120 / MHS MCS135 / MHS MCS150~170 / MHS150~ MCS185 / MHS MCS200 / MHS MCS220~235 / MHS220~ MCS260 / MHS MCS285~310/MHS285~ MCS330~380/MHS330~ Sound Level ST Overall Sound Level and Octave Band Level LN Overall Sound Level and Octave Band Level Electric Characteristics Wiring Diagram MCS050/060/070/080/100/120/135/150/170/185.1FST2(4) MCS200/220/235/260/285/310/330/350/380.2FST2(4) MHS050/060/070/080/100/120/135/150/170/185.1FST2(4) MHS200/220/235/260/285/310/330/350/380.2FST2(4) Electrical Data System Diagram Cooling System Heating pump system Installation Location of Water Circulating Pump Moving and Lifting Please perform the following checks before lifting Lifting method Refer to the following items if the units are installed where there s plenty of snow: Don t install the unit under the eaves... 88

4 Correct way to lift Don t install unit at places where snow will be accumulated When two or more units are positioned side by side, it s recommended that follow the below figure to do the installation: Hydraulic System Installation Guide Specifications Note: Installation and maintenance are to be performed only by qualified personnel who are familiar with local codes and regulations, and experienced with this type of equipment. Caution: Sharp edges and coil surfaces are a potential injury hazard. Avoid contact with them. Warning: Moving machinery and electrical power hazard. May cause severe personal injury or death. Disconnect and lock off power before servicing equipment. McQuay is a registered trademark of McQuay International. All rights reserved throughout the world McQuay International Bulletin illustrations cover the general appearance of McQuay International products at the time of publication and we reserve the right to make changes in design and construction at any time without notice.

5 1. Features 1.1 Features The air cooled chiller is a central air conditioning unit, using air as cooling heat source and water as cooling supply medium, which can meet the air conditioning requirement of buildings around the year. The unit can be mounted outside, therefore, no need for equipment room, cooling tower and related water piping system. The entire chiller is complete with simple structure and easy application. Our chiller can be applied in different application, such as department stores, hospitals, restaurants, factories, office building and so on. High resistance against corrosion The cabinet is coated to provide a high resistance. The unit can be applied under different environment conditions. The rejected heat from exchanger doesn t bring any pollution and meets the ecology requirement. Low noise and low vibration As the compact structure, the unit basement bears the loads of compressor, condenser, evaporator, oil separator and the weight of all related refrigerant piping. As our standard features, units are equipped with spring absorber. No vibration is expected from our unique type of F4 single screw compressor. The condenser fan is compete with high efficiency propeller fan, direct drive with low noise. The compressor sound insulation enclosure is provided as standard to decrease the compressor s operation noise effectively. Stepless modulation high efficiency and saving energy McQuay s unique newest single screw compressor brings high EER. Multiple circuits design, each unit is configured with one or two compressors and each compressor is configured with an independent refrigerant system, which can meet the load requirements. The cooling capacity can be steles ranging from 12.5% to 100% by micro-processor control. Easy to install and simple to maintain Once power supplies, water piping and water pump provided, no further equipment are needed. The chiller is fully equipped with the necessary electrical components. Our controller monitor the unit operation permanently. In case abnormity happens, the system can perform audio-video alarm and display the fault s cause to ease the maintenance. Exact control and reliable operation With most advanced electric expansion valve, the unit can control the refrigerant flow as various conditions. Chilled water leaving temperature is controlled to ±0.2. In addition, various sensors can transmit the signals and data to the controller, so the unit components are timely checked in order to keep reliable unit operation. Multiple protections ensure the safety operation of the unit. Three-level password protection prevents non-professional personnel from errors and ensures a safety operation. The compressor start one by one, so the electric current is low to reduce the impact to electric network. 5

6 1.2 Intelligent Network Controller The controller integrates the experience and technology, applying McQuay air cooled heat pump since last 30 years. It is equipped with forecast logical programming software to perform the best combination of compressor and fan at higher EER. The controller can check the parameters and settings and then act accordingly to improve the energy efficiency and maximum reliability. Main functions Multi protection,ensure unit high efficient and stable running. Unit cooling load auto adjusted based on evaporator outlet water temperature. Outlet water temperature controlled by PID, precision ±0.2 C. Compressor On/Off controlled according to average wear. Both Chinese and English are available. Unit operation status/temperature/pressure data etc dispaly. Fault alarm and fault history display. Three-level password protection. Auto re-start after power failure (option). Timing switch on/off function (option). Building management system control (option), Modbus, LonWorks, BACnet are available. Main components (Inner controller) 1. Main controller MicroTech Control type: PLC programming Software class: Class A Effective memory: Flash is 2+2MB, and static is 512KB Working condition: Temperature is between -25 C to 70 C, and relative humidity is 90% 2. PGD (Display) Language: Chinese or English Interface display: Large LCD, 4-line English or 2-line Chinese Working condition: Temperature is between -20 C to 60 C, and relative humidity is 92% 3. IO Expansion board No programming, Set the special address is available. 4. EVD200 No programming, Set the special address is available. Building Management system control (optional) Modbus/LonWorks/BACnet protocol interfaces are available to meet centralized and building auto control. 6

7 1.3 Single Screw Compressor Air Cooled Single Screw Chiller With leading technology, McQuay s semi-hermetic single screw compressor has such features as highefficiency, saving energy, stability, quietness, few operation components and long durability. Few operation components The single screw compressor is equipped with only five moving components: a screw, two gate rotors and two loading slide valve. The screw rotor outside is special treated, and the gate rotor is equipped with eleven-tooth high strength compound material. Liquid durability and high reliability With an equalizing compression, the single screw reduces the bearing load extending the bearing life span. The gate rotor, which is made of high flexibility synthetic material, can keep exact and minimum clearance to ensure no friction can happen, which can improve unit s efficiency. The oil ejection and liquid ejection design to the compressor avoid the overheat gas decrease to a minimum, eliminating to decompose the oil and refrigerant, keeping the good properties of the oil and refrigerant. Easy to maintain The gate rotor is accessible through a removing cover plate, making an easy maintenance. Bearing durability The bearing durability of the single screw compressor is up to 5 times or more, compared to twin-screw compressor. Low noise and low vibration The single screw compressor performs a complete balance load in operation, so its vibration is near to zero and its noise level reaches the minimum of the industry standard. It does not contact metal to metal in compression, which eliminates high frequency noise. Special design discharge chamber eliminates discharge noise. Rate rotor and rotors The single screw compressor, with excellent unique design and special gate-rotor material, and no need for metal hermetic requirement between the gate-rotor and rotors, reaches zero-interval. The liquid refrigerant brings more effects as hermetic, lubricant and cooling material when the compressor rotors operate. What s more, its interval of the teeth is very little and the resistance is very low, which can improve the unit s efficiency. High-efficiency oil separator The system is equipped with a high efficiency oil separator up to 99.7% efficiency. This improved the reliability and one more improvement to compression operation. 7

8 Compression principles Suction Gas flows through the suction port into open ends of available grooves. As the screw rotates, gate-rotor teeth enter the seal grooves in sequence, refrigerant gas in chambers defined by three sides of the grooves, the compressor casing and the gate-rotor tooth surface. Compression Volume in each tooth chamber decreases as the screw rotates. Gas is continuously compressed until the groove leading edge passes the discharge port. Discharge Release of gas into the discharge chamber ends the compression cycle. Gas continues to be discharged until the gate-rotor reduces groove volume to zero. With two gate-rotors equalized on opposite sides of the screw, this process occurs twice with each screw revolution, doubling the compressor capacity of the unit. Axial force balance With opposing and equal suction pressure at both ends of the screw member, the huge thrust loads of twinscrew compressor design are eliminated. Radial force balance Gate rotors on both sides of the screw member compressing simultaneously completely balanced radial loading on the rotating screw, nearly eliminates bearing wear. This is a sharp contrast with twin-screw designs whose bearing size is limited and higher loads directly impact bearing life. Twin-screw is with unbalance loading Without balance compression, the twinscrew increases axial loads and radial loads, and it increases abrasion, which affects the bearing life. Axial force balance Radial force balance Balanced stress with the single screw Unbalanced stress with the dual screws 8

9 2. Nomenclature Nomenclature (R22, R407C) MCS F ST 4 - F DA E Export Product Specifications Power Supply Refrigerant : 2---R R407C Unit : ST: standard LN: low noise Compressor Series Compressor Qty. Cooling Capacity: 235 USRT MCS: McQuay Single Screw Chiller MHS: McQuay Single Screw Heat Pump 9

10 3. Accessories 3.1 Standard accessories (supplied on basic unit) Star Delta Compressors starter For low inrush current and reduced starting torque. Compressor thermal overload relays Safety devices against compressor motor overloading in addition to the normal protection related to the electrical windings. Fan thermal overload relays Safety devices against fan motor overloading in addition to the normal protection related to the electrical windings. Phase protector The phase monitor with under/over voltage protection controls the phases sequence is correct and controls phase loss and ensure power supply voltage is corrrect. Evaporator electric heater Electric heater controlled by a thermostat to protect the evaporator from freezing. Victaulic evaporator water connection Hydraulic joint with gasket for an easy and quick water connection. General fault protection Contactor for alarm warning. Discharge line shut off valves Installed on the discharge port of the compressor. Suction line shut off valve Suction shut-off valve installed on the suction port of the compressor to facilitate maintenance operation (Only for MCS050/MCS060/MCS080). Flow switch Supplied separately to be wired and installed on the evaporator water piping (by the customer). Spring type vibration mounts Supplied separately, these have to be positioned under the base of the unit during installation. Ideal for dampening vibrations on roofs installation and metallic structures. 3.2 Optional accessories (on request) Glycol version Set-point can go down to -8 C. Speed control Continuous fan speed modulation on the first fan of each circuit. It allows the unit working with air temperature down to -15 C. Condenser coil guards Metal protection guards fixed on all the external surface of the condenser coils. Cu-Cu condenser coils To give better protection against corrosion by aggressive environments. Blue fin / Gold Fin Fins are protected by a special acrylic paint with a high resistance to corrosion. High pressure guages Low pressure guages Soft starter Electronic starting device to reduce inrush current and to start compressors gradually, with very low mechanical stress. BMS (Building Management System) protocol Modbus, LonWorks, BACnet 50/100Pa high static pressure fan Note: These options should be factory mounted. Field modifications are not available. 3.3 Safety devices and measures High pressure (pressure switch) Low pressure (pressure sensor) Compressor thermal Condensation fan thermal High compressor discharge temperature sensor Phase monitor Star/Delta transition failed Low-pressure ratio High oil pressure drop Low oil pressure Freeze protection Load stepless adjust Trouble record 10

11 4. Operation Limits 4.1 Operation Limits OPERATION LIMIT(COOL) OPERATION LIMIT(HEAT) OUTDOOR TEMP ( D.B.) Added Glycol Added fan speed controller OUTDOOR TEMP ( D.B.) Running range LEAVING CHILLED WATER TEMP( ) LEAVING HEATED WATER TEMP( ) NOTE: 1 At standard water flow rate; 2 Using ethylene glycol,lwt can reach to -8 ; 3 The range of relative humidity is below 90%. Unload area Recommended area 4.2 System Water Volume It is important to have adequate water volume in the system to provide an opportunity for the chiller to sense a load change, adjust to the change and stabilize. As the expected load change becomes more rapid, a greater water volume is needed. The system water volume is the total amount of water in the evaporator, air handling products and associated piping. If the water volume is too low, operational problems can occur including rapid compressor cycling, rapid loading and unloading of compressors, erratic refrigerant flow in the chiller, improper motor cooling, shortened equipment life and other undesirable occurrences. For normal comfort cooling applications where the cooling load changes relatively slowly, we recommend a minimum system volume. Calculation of the water volume (m 3 ) is as below: L = P where: L = minimum water volume (m 3 ) P = nominal cooling capacity (kw) 4.3 Water flow range Model MHS/MCS Water Flow Rate Range m 3 /h 25~40 25~48 32~56 34~66 43~85 51~99 55~107 63~124 75~147 78~153 Model Water Flow Rate Range m 3 /h 87~169 95~ ~ ~ ~ ~ ~ ~ ~321 11

12 5. Specifications 5.1 MHS/MCS 050.1FST~MHS/MCS380.2FST[R22 ] MHS/MCS kw *1 Normal Cooling Capacity USRT kcal/h 146, , , , ,600 Btu/h 580, , , ,900 1,229,000 kw *2 Normal Heating Capacity 10 4 kcal/h 153, , , , , Btu/h 610, , ,000 1,003,000 1,290,000 Capacity Steps 25 ~ 100% Power Supply V/3N/50Hz Semi-hermetic Single-screw Compressor No. Model Motor Power Input Cooling kw Motor Power Input Heating kw Refrigerant Oil Model LPT68 Charge L High-efficiency Shell and Tube Evaporator Flow Rate L/min Pressure Drop kpa Cross Fin and Tube Condenser Rows Stages FPI 14 Face Area m Propeller (Direct Drive) Qty Fan m 3 /min. 1,467 1,467 2,200 2,200 2,933 Air Flow Rate cfm 51,773 51,773 77,660 77, ,547 Motor Input kw R22 Refrigerant No. of Circuits Control Electronic Expansion Valve Water Piping Connection inch 5 Compressor Acoustic Insulation Material Polyurethane Foaming Unit Power Input kw L mm Unit W mm 2260 Dimensions H mm 2290 MCS Shipping Weight kg Weight MCS Operation Weight kg MHS Shipping Weight kg MHS Operation Weight kg Standard Accessories Unit Operation Instructions, Conformity Certificate, Warranty Application Form, Spring Damper, Water Flow Switch. Notes: *1. Cooling capacity is based on the following conditions: Entering chilled water temp. 12 C, Leaving chilled water temp. 7 C, ambient temp. 35 C DB *2. Heating capacity is based on the following conditions: Entering chilled water temp. 40 C, Leaving chilled water temp. 45 C, ambient temp. 7 C DB Conversion Formulae kcal/h=kw 860 Btu/h=kW 3414 cfm=m³/min

13 MHS/MCS kw *1 Normal Cooling Capacity USRT kcal/h 362, , , , ,400 Btu/h 1,440,700 1,553,400 1,792,400 2,133,800 2,232,800 kw *2 Normal Heating Capacity 10 4 kcal/h 380, , , , , Btu/h 1,512,000 1,631,000 1,881,000 2,239,000 2,345,000 Capacity Steps 25 ~ 100% Power Supply V/3N/50Hz Semi-hermetic Single-screw Compressor No. Model Motor Power Input Cooling kw Motor Power Input Heating kw Refrigerant Model LPT68 Oil Charge L High-efficiency Shell and Tube Evaporator Flow Rate L/min Pressure Drop kpa Cross Fin and Tube Condenser Rows Stages FPI 14 Face Area m Propeller (Direct Drive) No Fan m 3 /min. 2,933 2,933 3,667 3,667 4,400 Air Flow Rate cfm 103, , , , ,320 Motor Input kw R22 Refrigerant No. of Circuits Control Electronic Expansion Valve Water Piping Connection inch 8 Compressor Acoustic Insulation Material Polyurethane Foaming Unit Power Input kw L mm Unit W mm 2260 Dimensions H mm MCS Shipping Weight kg Weight MCS Operation Weight kg MHS Shipping Weight kg MHS Operation Weight kg Standard Accessories Unit Operation Instructions, Conformity Certificate, Warranty Application Form, Spring Damper, Water Flow Switch. Notes: *1. Cooling capacity is based on the following conditions: Entering chilled water temp. 12 C, Leaving chilled water temp. 7 C, ambient temp. 35 C DB *2. Heating capacity is based on the following conditions: Entering chilled water temp. 40 C, Leaving chilled water temp. 45 C, ambient temp. 7 C DB Conversion Formulae kcal/h=kw 860 Btu/h=kW 3414 cfm=m³/min

14 MHS/MCS kw *1 Normal Cooling Capacity USRT kcal/h 619, , , , ,000 Btu/h 2,458,100 2,669,800 2,867,800 3,243,300 3,414,000 kw *2 Normal Heating Capacity 10 4 kcal/h 650, , , , , Btu/h 2,580,000 2,802,000 3,010,000 3,406,000 3,584,000 Capacity Steps 12.5 ~ 100% Power Supply V/3N/50Hz Semi-hermetic Single-screw No. Model Compressor Motor Power Input Cooling kw Motor Power Input Heating kw Refrigerant Model LPT68 Oil Charge L High-efficiency Shell and Tube Evaporator Flow Rate L/min Pressure Drop kpa Cross Fin and Tube Condenser Rows Stages FPI 14 Face Area m Propeller (Direct Drive) Qty Fan m 3 /min. 5,133 5,500 5,867 5,867 6,233 Air Flow Rate cfm 181, , , , ,037 Motor Input kw R22 Refrigerant No. of Circuits Control Electronic Expansion Valve Water Piping Connection inch 8 Compressor Acoustic Insulation Material Polyurethane Foaming Unit Power Input kw Unit Dimensions Weight Standard Accessories L mm W mm 2260 H mm 2330 MCS Shipping Weight kg MCS Operation Weight kg MHS Shipping Weight kg MHS Operation Weight kg Unit Operation Instructions, Conformity Certificate, Warranty Application Form, Spring Damper, Water Flow Switch. Notes: *1. Cooling capacity is based on the following conditions: Entering chilled water temp. 12 C, Leaving chilled water temp. 7 C, ambient temp. 35 C DB *2. Heating capacity is based on the following conditions: Entering chilled water temp. 40 C, Leaving chilled water temp. 45 C, ambient temp. 7 C DB Conversion Formulae kcal/h=kw 860 Btu/h=kW 3414 cfm=m³/min

15 MHS/MCS kw *1 Normal Cooling Capacity USRT kcal/h 920,200 1,000,200 1,118,000 1,178,200 Btu/h 3,653,000 3,970,500 4,438,200 4,677,200 kw *2 Normal Heating Capacity 10 4 kcal/h 966,000 1,049,816 1,174,000 1,237, Btu/h 3,836,178 4,167,000 4,659,000 4,911,000 Capacity Steps 12.5 ~ 100% Power Supply V/3N/50Hz Semi-hermetic Single-screw Compressor No. Model Motor Power Input Cooling kw Motor Power Input Heating kw Refrigerant Oil Model LPT68 Charge L High-efficiency Shell and Tube Evaporator Flow Rate L/min Pressure Drop kpa Cross Fin and Tube Condenser Rows Stages FPI 14 Face Area m Propeller (Direct Drive) Qty Fan m 3 /min. 6,600 6,967 7,333 7,333 Air Flow Rate cfm 232, , , ,867 Motor Input kw R22 Refrigerant No. of Circuits Control Electronic Expansion Valve Water Piping Connection inch 8 Compressor Acoustic Insulation Material Polyurethane Foaming Unit Power Input kw Unit Dimensions Weight Standard Accessories L mm W mm 2260 H mm 2330 MCS Shipping Weight kg MCS Operation Weight kg MHS Shipping Weight kg MHS Operation Weight kg Unit Operation Instructions, Conformity Certificate, Warranty Application Form, Spring Damper, Water Flow Switch. Notes: *1. Cooling capacity is based on the following conditions: Entering chilled water temp. 12 C, Leaving chilled water temp. 7 C, ambient temp. 35 C DB *2. Heating capacity is based on the following conditions: Entering chilled water temp. 40 C, Leaving chilled water temp. 45 C, ambient temp. 7 C DB Conversion Formulae kcal/h=kw 860 Btu/h=kW 3414 cfm=m³/min

16 5.2 MHS/MCS050.1FST~MHS/MCS350.2FST[R407C] MHS/MCS kw *1 Normal Cooling Capacity USRT kcal/h 141, , , , ,800 Btu/h 560, , , ,500 1,186,000 kw *2 Normal Heating Capacity 10 4 kcal/h 153, , , , , Btu/h 611, , ,000 1,003,413 1,290,000 Capacity Steps 25 ~ 100% Power Supply V/3N/50Hz Semi-hermetic Single-screw Compressor No. Model Motor Power Input Cooling kw Motor Power Input Heating kw Refrigerant Model RL68H Oil Charge L High-efficiency Shell and Tube Evaporator Flow Rate L/min Pressure Drop kpa Cross Fin and Tube Condenser Rows Stages FPI 14 Face Area m Propeller (Direct Drive) Qty Fan m 3 /min. 1,467 1,467 2,200 2,200 2,933 Air Flow Rate cfm 51,773 51,773 77,660 77, ,547 Motor Input kw R407C Refrigerant No. of Circuits Control Electronic Expansion Valve Water Piping Connection inch 5 Compressor Acoustic Insulation Material Polyurethane Foaming Unit Power Input kw L mm Unit W mm 2260 Dimensions H mm 2290 MCS Shipping Weight kg Weight MCS Operation Weight kg MHS Shipping Weight kg MHS Operation Weight kg Standard Accessories Unit Operation Instructions, Conformity Certificate, Warranty Application Form, Spring Damper, Water Flow Switch. Notes: *1. Cooling capacity is based on the following conditions: Entering chilled water temp. 12 C, Leaving chilled water temp. 7 C, ambient temp. 35 C DB *2. Heating capacity is based on the following conditions: Entering chilled water temp. 40 C, Leaving chilled water temp. 45 C, ambient temp. 7 C DB Conversion Formulae kcal/h=kw 860 Btu/h=kW 3414 cfm=m³/min

17 MHS/MCS kw *1 Normal Cooling Capacity USRT kcal/h 350, , , , ,800 Btu/h 1,390,300 1,499,000 1,729,600 2,059,100 2,154,600 kw *2 Normal Heating Capacity 10 4 kcal/h 381, , , , , Btu/h 1,512,000 1,631,400 1,880,600 2,239,000 2,344,800 Capacity Steps 25 ~ 100% Power Supply V/3N/50Hz Semi-hermetic Single-screw Compressor No. Model Motor Power Input Cooling kw Motor Power Input Heating kw Refrigerant Oil Model RL68H Charge L High-efficiency Shell and Tube Evaporator Flow Rate L/min Pressure Drop kpa Cross Fin and Tube Condenser Rows Stages FPI 14 Face Area m Propeller (Direct Drive) Qty Fan m 3 /min. 2,933 2,933 3,667 3,667 4,400 Air Flow Rate cfm 103, , , , ,320 Motor Input kw R407C Refrigerant No. of Circuits Control Electronic Expansion Valve Water Piping Connection inch 8 Compressor Acoustic Insulation Material Polyurethane Foaming Unit Power Input kw Unit Dimensions Weight Standard Accessories L mm W mm 2260 H mm MCS Shipping Weight kg MCS Operation Weight kg MHS Shipping Weight kg MHS Operation Weight kg Unit Operation Instructions, Conformity Certificate, Warranty Application Form, Spring Damper, Water Flow Switch. Notes: *1. Cooling capacity is based on the following conditions: Entering chilled water temp. 12 C, Leaving chilled water temp. 7 C, ambient temp. 35 C DB *2. Heating capacity is based on the following conditions: Entering chilled water temp. 40 C, Leaving chilled water temp. 45 C, ambient temp. 7 C DB Conversion Formulae kcal/h=kw 860 Btu/h=kW 3414 cfm=m³/min

18 MHS/MCS kw *1 Normal Cooling Capacity USRT kcal/h 597, , , , ,900 Btu/h 2,372,000 2,576,300 2,767,400 3,129,800 3,294,500 kw *2 Normal Heating Capacity 10 4 kcal/h 650, , , , , Btu/h 2,580,000 2,802,000 3,010,240 3,406,000 3,584,000 Capacity Steps 12.5 ~ 100% Power Supply V/3N/50Hz Semi-hermetic Single-screw No. Model Compressor Motor Power Input Cooling kw Motor Power Input Heating kw Refrigerant Model RL68H Oil Charge L High-efficiency Shell and Tube Evaporator Flow Rate L/min Pressure Drop kpa Cross Fin and Tube Condenser Rows Stages FPI 14 Face Area m Propeller (Direct Drive) Qty Fan m 3 /min. 5,133 5,500 5,867 5,867 6,233 Air Flow Rate cfm 181, , , , ,037 Motor Input kw R407C Refrigerant No. of Circuits Control Electronic Expansion Valve Water Piping Connection inch 8 Compressor Acoustic Insulation Material Polyurethane Foaming Unit Power Input kw Unit Dimensions Weight Standard Accessories L mm W mm 2260 H mm 2330 MCS Shipping Weight kg MCS Operation Weight kg MHS Shipping Weight kg MHS Operation Weight kg Unit Operation Instructions, Conformity Certificate, Warranty Application Form, Spring Damper, Water Flow Switch. Notes: *1. Cooling capacity is based on the following conditions: Entering chilled water temp. 12 C, Leaving chilled water temp. 7 C, ambient temp. 35 C DB *2. Heating capacity is based on the following conditions: Entering chilled water temp. 40 C, Leaving chilled water temp. 45 C, ambient temp. 7 C DB Conversion Formulae kcal/h=kw 860 Btu/h=kW 3414 cfm=m³/min

19 MHS/MCS kw *1 Normal Cooling Capacity USRT kcal/h 888, ,200 1,078,900 Btu/h 3,525,100 3,831,500 4,282,900 kw *2 Normal Heating Capacity 10 4 kcal/h 966,400 1,049,900 1,173, Btu/h 3,836,000 4,167,000 4,659,000 Capacity Steps 12.5 ~ 100% Power Supply V/3N/50Hz Semi-hermetic Single-screw Compressor No. Model Motor Power Input Cooling kw Motor Power Input Heating kw Refrigerant Model RL68H Oil Charge L High-efficiency Shell and Tube Evaporator Flow Rate L/min Pressure Drop kpa Cross Fin and Tube Condenser Rows Stages FPI 14 Face Area m Propeller (Direct Drive) Qty Fan m 3 /min. 6,600 6,967 7,333 Air Flow Rate cfm 232, , ,867 Motor Input kw R407C Refrigerant No. of Circuits Control Electronic Expansion Valve Water Piping Connection inch 8 Compressor Acoustic Insulation Material Polyurethane Foaming Unit Power Input kw L mm Unit W mm 2260 Dimensions H mm 2330 MCS Shipping Weight kg Weight MCS Operation Weight kg MHS Shipping Weight kg MHS Operation Weight kg Standard Accessories Unit Operation Instructions, Conformity Certificate, Warranty Application Form, Spring Damper, Water Flow Switch. Notes: *1. Cooling capacity is based on the following conditions: Entering chilled water temp. 12 C, Leaving chilled water temp. 7 C, ambient temp. 35 C DB *2. Heating capacity is based on the following conditions: Entering chilled water temp. 40 C, Leaving chilled water temp. 45 C, ambient temp. 7 C DB Conversion Formulae kcal/h=kw 860 Btu/h=kW 3414 cfm=m³/min

20 5.3 MHS/MCS050.1FLN~MHS/MCS350.2FLN[R22] MHS/MCS kw *1 Normal Cooling Capacity USRT kcal/h 140, , , , ,000 Btu/h 570, , , ,000 1,200,000 kw *2 Normal Heating Capacity 10 4 kcal/h Btu/h Capacity Steps 25 ~ 100% Power Supply V/3N/50Hz Semi-hermetic Single-screw Compressor No. Model Motor Power Input Cooling kw Motor Power Input Heating kw Refrigerant Model LPT68 Oil Charge L High-efficiency Shell and Tube Evaporator Flow Rate L/min Pressure Drop kpa Cross Fin and Tube Condenser Rows Stages FPI 14 Face Area m Propeller (Direct Drive) Qty Fan m 3 /min. 1,200 1,200 1,800 1,800 2,400 Air Flow Rate cfm 42,360 42,360 63,540 63,540 84,720 Motor Input kw R22 Refrigerant No. of Circuits Control Electronic Expansion Valve Water Piping Connection inch 5 Compressor Acoustic Insulation Material Polyurethane Foaming Unit Power Input kw Unit Dimensions Weight Standard Accessories L mm W mm 2260 H mm 2290 MCS Shipping Weight kg MCS Operation Weight kg MHS Shipping Weight kg MHS Operation Weight kg Unit Operation Instructions, Conformity Certificate, Warranty Application Form, Spring Damper, Water Flow Switch. Notes: *1. Cooling capacity is based on the following conditions: Entering chilled water temp. 12 C, Leaving chilled water temp. 7 C, ambient temp. 35 C DB *2. Heating capacity is based on the following conditions: Entering chilled water temp. 40 C, Leaving chilled water temp. 45 C, ambient temp. 7 C DB Conversion Formulae kcal/h=kw 860 Btu/h=kW 3414 cfm=m³/min

21 MHS/MCS kw *1 Normal Cooling Capacity USRT kcal/h 360, , , , ,000 Btu/h 1,410,000 1,520,000 1,760,000 2,09,000 2,190,000 kw *2 Normal Heating Capacity 10 4 kcal/h Btu/h Capacity Steps 25 ~ 100% Power Supply V/3N/50Hz Semi-hermetic Single-screw Compressor No. Model Motor Power Input Cooling kw Motor Power Input Heating kw Refrigerant Model LPT68 Oil Charge L High-efficiency Shell and Tube Evaporator Flow Rate L/min Pressure Drop kpa Cross Fin and Tube Condenser Rows Stages FPI 14 Face Area m Propeller (Direct Drive) Qty Fan m 3 /min. 2,400 2,400 3,000 3,000 3,600 Air Flow Rate cfm 84,720 84, , , ,080 Motor Input kw R22 Refrigerant No. of Circuits Control Electronic Expansion Valve Water Piping Connection inch 8 Compressor Acoustic Insulation Material Polyurethane Foaming Unit Power Input kw Unit Dimensions Weight Standard Accessories L mm W mm 2260 H mm MCS Shipping Weight kg MCS Operation Weight kg MHS Shipping Weight kg MHS Operation Weight kg Unit Operation Instructions, Conformity Certificate, Warranty Application Form, Spring Damper, Water Flow Switch. Notes: *1. Cooling capacity is based on the following conditions: Entering chilled water temp. 12 C, Leaving chilled water temp. 7 C, ambient temp. 35 C DB *2. Heating capacity is based on the following conditions: Entering chilled water temp. 40 C, Leaving chilled water temp. 45 C, ambient temp. 7 C DB Conversion Formulae kcal/h=kw 860 Btu/h=kW 3414 cfm=m³/min

22 MHS/MCS kw *1 Normal Cooling Capacity USRT kcal/h 610, , , , ,000 Btu/h 2,410,000 2,610,000 2,850,000 3,180,000 3,340,000 kw *2 Normal Heating Capacity 10 4 kcal/h Btu/h Capacity Steps 12.5 ~ 100% Power Supply V/3N/50Hz Semi-hermetic Single-screw No. Model Compressor Motor Power Input Cooling kw Motor Power Input Heating kw Refrigerant Model LPT68 Oil Charge L High-efficiency Shell and Tube Evaporator Flow Rate L/min Pressure Drop kpa Cross Fin and Tube Condenser Rows Stages FPI 14 Face Area m Propeller (Direct Drive) Qty Fan m 3 /min. 4,200 4,500 4,800 4,800 5,100 Air Flow Rate cfm 148, , , , ,030 Motor Input kw R22 Refrigerant No. of Circuits Control Electronic Expansion Valve Water Piping Connection inch 8 Compressor Acoustic Insulation Material Polyurethane Foaming Unit Power Input kw Unit Dimensions Weight Standard Accessories L mm W mm 2260 H mm 2330 MCS Shipping Weight kg MCS Operation Weight kg MHS Shipping Weight kg MHS Operation Weight kg Unit Operation Instructions, Conformity Certificate, Warranty Application Form, Spring Damper, Water Flow Switch. Notes: *1. Cooling capacity is based on the following conditions: Entering chilled water temp. 12 C, Leaving chilled water temp. 7 C, ambient temp. 35 C DB *2. Heating capacity is based on the following conditions: Entering chilled water temp. 40 C, Leaving chilled water temp. 45 C, ambient temp. 7 C DB Conversion Formulae kcal/h=kw 860 Btu/h=kW 3414 cfm=m³/min

23 MHS/MCS kw *1 Normal Cooling Capacity USRT kcal/h 900, ,200 1,100,000 Btu/h 3,580,000 3,890,000 4,350,000 kw *2 Normal Heating Capacity 10 4 kcal/h Btu/h Capacity Steps 12.5 ~ 100% Power Supply V/3N/50Hz Semi-hermetic Single-screw Compressor No. Model Motor Power Input Cooling kw Motor Power Input Heating kw Refrigerant Oil Model LPT68 Charge L High-efficiency Shell and Tube Evaporator Flow Rate L/min Pressure Drop kpa Cross Fin and Tube Condenser Rows Stages FPI 14 Face Area m Propeller (Direct Drive) Qty Fan m 3 /min. 5,400 5,700 6,000 Air Flow Rate cfm 190, , ,800 Motor Input kw R22 Refrigerant No. of Circuits Control Electronic Expansion Valve Water Piping Connection inch 8 Compressor Acoustic Insulation Material Polyurethane Foaming Unit Power Input kw Unit Dimensions Weight Standard Accessories L mm W mm 2260 H mm 2330 MCS Shipping Weight kg MCS Operation Weight kg MHS Shipping Weight kg MHS Operation Weight kg Unit Operation Instructions, Conformity Certificate, Warranty Application Form, Spring Damper, Water Flow Switch. Notes: *1. Cooling capacity is based on the following conditions: Entering chilled water temp. 12 C, Leaving chilled water temp. 7 C, ambient temp. 35 C DB *2. Heating capacity is based on the following conditions: Entering chilled water temp. 40 C, Leaving chilled water temp. 45 C, ambient temp. 7 C DB Conversion Formulae kcal/h=kw 860 Btu/h=kW 3414 cfm=m³/min

24 5.4 MHS/MCS050.1FLN~MCS350.2FLN[R407C] MHS/MCS kw *1 Normal Cooling Capacity USRT kcal/h 140, , , , ,000 Btu/h 550, , , ,000 1,160,000 kw *2 Normal Heating Capacity 10 4 kcal/h Btu/h Capacity Steps 25 ~ 100% Power Supply V/3N/50Hz Semi-hermetic Single-screw Compressor No. Model Motor Power Input Cooling kw Motor Power Input Heating kw Refrigerant Model RL68H Oil Charge L High-efficiency Shell and Tube Evaporator Flow Rate L/min Pressure Drop kpa Cross Fin and Tube Condenser Rows Stages FPI 14 Face Area m Propeller (Direct Drive) Qty Fan m 3 /min. 1,200 1,200 1,800 1,800 2,400 Air Flow Rate cfm 42,360 42,360 63,540 63,540 84,720 Motor Input kw R407C Refrigerant No. of Circuits Control Electronic Expansion Valve Water Piping Connection inch 5 Compressor Acoustic Insulation Material Polyurethane Foaming Unit Power Input kw Unit Dimensions Weight Standard Accessories L mm W mm 2260 H mm 2290 MCS Shipping Weight kg MCS Operation Weight kg MHS Shipping Weight kg MHS Operation Weight kg Unit Operation Instructions, Conformity Certificate, Warranty Application Form, Spring Damper, Water Flow Switch. Notes: *1. Cooling capacity is based on the following conditions: Entering chilled water temp. 12 C, Leaving chilled water temp. 7 C, ambient temp. 35 C DB *2. Heating capacity is based on the following conditions: Entering chilled water temp. 40 C, Leaving chilled water temp. 45 C, ambient temp. 7 C DB Conversion Formulae kcal/h=kw 860 Btu/h=kW 3414 cfm=m³/min

25 MHS/MCS kw *1 Normal Cooling Capacity USRT kcal/h 340, , , , ,000 Btu/h 1,360,000 1,470,000 1,690,000 2,020,000 2,110,000 kw *2 Normal Heating Capacity 10 4 kcal/h Btu/h Capacity Steps 25 ~ 100% Power Supply V/3N/50Hz Semi-hermetic Single-screw Compressor No. Model Motor Power Input Cooling kw Motor Power Input Heating kw Refrigerant Oil Model RL68H Charge L High-efficiency Shell and Tube Evaporator Flow Rate L/min Pressure Drop kpa Cross Fin and Tube Condenser Rows Stages FPI 14 Face Area m Propeller (Direct Drive) Qty Fan m 3 /min. 2,400 2,400 3,667 3,000 3,600 Air Flow Rate cfm 84,720 84, , , ,080 Motor Input kw R407C Refrigerant No. of Circuits Control Electronic Expansion Valve Water Piping Connection inch 8 Compressor Acoustic Insulation Material Polyurethane Foaming Unit Power Input kw Unit Dimensions Weight Standard Accessories L mm W mm 2260 H mm MCS Shipping Weight kg MCS Operation Weight kg MHS Shipping Weight kg MHS Operation Weight kg Unit Operation Instructions, Conformity Certificate, Warranty Application Form, Spring Damper, Water Flow Switch. Notes: *1. Cooling capacity is based on the following conditions: Entering chilled water temp. 12 C, Leaving chilled water temp. 7 C, ambient temp. 35 C DB *2. Heating capacity is based on the following conditions: Entering chilled water temp. 40 C, Leaving chilled water temp. 45 C, ambient temp. 7 C DB Conversion Formulae kcal/h=kw 860 Btu/h=kW 3414 cfm=m³/min

26 MHS/MCS kw *1 Normal Cooling Capacity USRT kcal/h 590, , , , ,000 Btu/h 2,320,000 2,520,000 2,710,000 3,070,000 3,230,000 kw *2 Normal Heating Capacity 10 4 kcal/h Btu/h Capacity Steps 12.5 ~ 100% Power Supply V/3N/50Hz Semi-hermetic Single-screw No. Model Compressor Motor Power Input Cooling kw Motor Power Input Heating kw Refrigerant Model RL68H Oil Charge L High-efficiency Shell and Tube Evaporator Flow Rate L/min Pressure Drop kpa Cross Fin and Tube Condenser Rows Stages FPI 14 Face Area m Propeller (Direct Drive) Qty Fan m 3 /min. 4,200 4,500 4,800 4,800 5,100 Air Flow Rate cfm 148, , , , ,030 Motor Input kw R407C Refrigerant No. of Circuits Control Electronic Expansion Valve Water Piping Connection inch 8 Compressor Acoustic Insulation Material Polyurethane Foaming Unit Power Input kw Unit Dimensions Weight Standard Accessories L mm W mm 2260 H mm 2330 MCS Shipping Weight kg MCS Operation Weight kg MHS Shipping Weight kg MHS Operation Weight kg Unit Operation Instructions, Conformity Certificate, Warranty Application Form, Spring Damper, Water Flow Switch. Notes: *1. Cooling capacity is based on the following conditions: Entering chilled water temp. 12 C, Leaving chilled water temp. 7 C, ambient temp. 35 C DB * 2. Heating capacity is based on the following conditions: Entering chilled water temp. 40 C, Leaving chilled water temp. 45 C, ambient temp. 7 C DB Conversion Formulae kcal/h=kw 860 Btu/h=kW 3414 cfm=m³/min

27 MHS/MCS kw *1 Normal Cooling Capacity USRT kcal/h 870, ,000 1,060,000 Btu/h 3,450,000 3,750,000 4,190,000 kw *2 Normal Heating Capacity 10 4 kcal/h Btu/h Capacity Steps 12.5 ~ 100% Power Supply V/3N/50Hz Semi-hermetic Single-screw Compressor No. Model Motor Power Input Cooling kw Motor Power Input Heating kw Refrigerant Model RL68H Oil Charge L High-efficiency Shell and Tube Evaporator Flow Rate L/min Pressure Drop kpa Cross Fin and Tube Condenser Rows Stages FPI 14 Face Area m Propeller (Direct Drive) Qty. 18 TFE TFE TFE Fan m 3 /min. 5,400 5,700 6,000 Air Flow Rate cfm 190, , ,800 Motor Input kw R407C Refrigerant No. of Circuits Control Electronic Expansion Valve Water Piping Connection inch 8 Compressor Acoustic Insulation Material Polyurethane Foaming Unit Power Input kw L mm Unit W mm 2260 Dimensions H mm 2330 MCS Shipping Weight kg Weight MCS Operation Weight kg MHS Shipping Weight kg MHS Operation Weight kg Standard Accessories Unit Operation Instructions, Conformity Certificate, Warranty Application Form, Spring Damper, Water Flow Switch. Notes: *1. Cooling capacity is based on the following conditions: Entering chilled water temp. 12 C, Leaving chilled water temp. 7 C, ambient temp. 35 C DB *2. Heating capacity is based on the following conditions: Entering chilled water temp. 40 C, Leaving chilled water temp. 45 C, ambient temp. 7 C DB Conversion Formulae kcal/h=kw 860 Btu/h=kW 3414 cfm=m³/min

28 6. Correction Fouling factors (water side heat exchanger) Fouling factor (m 2 C/kw) Cooling capacity correction Power correction COP correction Altitude correction factors Elevation above sea level (m) Barometric pressure (bar) Cooling capacity correction factor Power input correction factor Ethylene glycol correction factors % Of ethylene glycol by weight Cooling capacity correction factor Power input correction factor Water flow rate correction factor Water pressure drops correction factor Low temperature operation performance factors Ethylene glycol leaving water temperature of chilled water ( C) Max. ambient temperature ( C) Cooling capacity correction factor Power input of compressor correction factor Min. % of ethylene glycol Notes: Average sound pressure level is according to ISO 3744, semispheric free field conditions. Sound pressure levels are referred to units furnished without hydraulic kit. Measuring location is at 1m from the unit in semispheric free field (rif Pa). 28

29 7. Capacity Tables 7.1 Cooling Capacity Tables MHS/MCS050.1FST~MHS/MCS380.2FST[R22] Model MHS050.1 MHS060.1 MHS070.1 MHS080.1 MHS100.1 MHS120.1 MHS135.1 MHS150.1 MHS170.1 LWT C NOTES: CAP: cooling capacity (kw) PI: power input (kw) Ambient temperature ( C) CAP PI CAP PI CAP PI CAP PI CAP PI CAP PI kw

30 Model MHS185.1 MHS200.2 MHS220.2 MHS235.2 MHS260.2 MHS285.2 MHS310.2 MHS330.2 MHS350.2 MHS380.2 LWT C Ambient temperature ( C) CAP PI CAP PI CAP PI CAP PI CAP PI CAP PI kw NOTES: CAP: cooling capacity (kw) PI: power input (kw) 30

31 7.1.2 MHS050.1FST~MHS350.2FST[R407C] Model MHS050.1 MHS060.1 MHS070.1 MHS080.1 MHS100.1 MHS120.1 MHS135.1 MHS150.1 MHS170.1 LWT C Ambient temperature ( C) CAP PI CAP PI CAP PI CAP PI CAP PI CAP PI kw NOTES: CAP: cooling capacity (kw) PI: power input (kw) 31

32 Model MHS185.1 MHS200.2 MHS220.2 MHS235.2 MHS260.2 MHS285.2 MHS310.2 MHS330.2 MHS350.2 LWT C Ambient temperature ( C) CAP PI CAP PI CAP PI CAP PI CAP PI CAP PI kw NOTES: CAP: cooling capacity (kw) PI: power input (kw) 32

33 7.1.3 MHS050.1FLN~MHS350.2FLN[R22] Model MHS050.1 MHS060.1 MHS070.1 MHS080.1 MHS100.1 MHS120.1 MHS135.1 MHS150.1 MHS170.1 LWT C Ambient temperature ( C) CAP PI CAP PI CAP PI CAP PI CAP PI kw NOTES: CAP: cooling capacity (kw) PI: power input (kw) 33

34 Model MHS185.1 MHS200.2 MHS220.2 MHS235.2 MHS260.2 MHS285.2 MHS310.2 MHS330.2 MHS350.2 LWT C Ambient temperature ( C) CAP PI CAP PI CAP PI CAP PI CAP PI kw NOTES: CAP: cooling capacity (kw) PI: power input (kw) 34

35 Model MHS050.1 MHS060.1 MHS070.1 MHS080.1 MHS100.1 MHS120.1 MHS135.1 MHS150.1 MHS170.1 LWT C Ambient temperature ( C) CAP PI CAP PI CAP PI CAP PI CAP PI kw NOTES: CAP: cooling capacity (kw) PI: power input (kw) 35

36 Model MHS185.1 MHS200.2 MHS220.2 MHS235.2 MHS260.2 MHS285.2 MHS310.2 MHS330.2 MHS350.2 LWT C Ambient temperature ( C) CAP PI CAP PI CAP PI CAP PI CAP PI kw NOTES: CAP: cooling capacity (kw) PI: power input (kw) 36

37 7.2 Heating Capacity Table MHS050.1FST2-MHS380.1FST2 Model MHS050.1 MHS060.1 MHS070.1 MHS080.1 MHS100.1 MHS120.1 MHS135.1 MHS150.1 MHS170.1 MHS185.1 MHS200.2 MHS220.2 MHS235.2 MHS260.2 MHS285.2 MHS310.2 Ambient temperature ( C) LWT C CAP PI CAP PI CAP PI CAP PI CAP PI CAP PI CAP PI CAP PI kw

38 Ambient temperature ( C) Model MHS330.2 MHS350.2 MHS LWT C CAP PI CAP PI CAP PI CAP PI CAP PI CAP PI CAP PI CAP PI kw

39 7.2.2 MHS050.1FST4-MHS380.2FST4 Ambient temperature ( C) Model MHS050.1 MHS060.1 MHS070.1 MHS080.1 MHS100.1 MHS120.1 MHS135.1 MHS150.1 MHS170.1 MHS185.1 MHS200.2 MHS220.2 MHS235.2 MHS260.2 MHS285.2 MHS LWT C CAP PI CAP PI CAP PI CAP PI CAP PI CAP PI CAP PI CAP PI kw

40 Model MHS330.2 MHS350.2 Ambient temperature ( C) LWT C CAP PI CAP PI CAP PI CAP PI CAP PI CAP PI CAP PI CAP PI kw

41 7.2.3 MHS050.1FLN2-MHS380.2FLN2 Ambient temperature ( C) Model LWT C CAP PI CAP PI CAP PI CAP PI CAP PI CAP PI CAP PI CAP PI MHS050.1 MHS060.1 MHS070.1 MHS080.1 MHS100.1 MHS120.1 MHS135.1 MHS150.1 MHS170.1 MHS185.1 MHS200.2 MHS220.2 MHS235.2 MHS260.2 MHS285.2 MHS310.2 k

42 Model Ambient temperature ( C) LWT C CAP PI CAP PI CAP PI CAP PI CAP PI CAP PI CAP PI CAP PI MHS330.2 MHS

43 7.2.4 MHS050.1FLN4-MHS380.2FLN4 Ambient temperature ( C) Model LWT C CAP PI CAP PI CAP PI CAP PI CAP PI CAP PI CAP PI CAP PI MHS050.1 MHS060.1 MHS070.1 MHS080.1 MHS100.1 MHS120.1 MHS135.1 MHS150.1 MHS170.1 MHS185.1 MHS200.2 MHS220.2 MHS235.2 MHS260.2 MHS285.2 MHS310.2 kw

44 Ambient temperature ( C) Model LWT C CAP PI CAP PI CAP PI CAP PI CAP PI CAP PI CAP PI CAP PI MHS330.2 MHS350.2 kw

45 8. Pressure Drop Through Evaporator Pressure drop (KPa) Water flow rate (L/S) 45

46 9. Dimensions MCS050~060 / MHS050~ "(OD139.7) 5"(OD139.7) Condensor 2 Evaporator 3 Evaporator water inlet 4 Evaporator water outlet 5 Control box 6 Fans unit: mm

47 MCS050~060 / MHS050~060 : 47

48 MCS070~080 / MHS070~080 : 48

49 MCS100~185 / MHS100~185 : ) ) ) ) ) 49

50 MCS200~380 / MHS200~380 ) ) ) ) : 50

51 MCS100~185 / MHS100~185 H C 4 A B unit: mm D Note: Fans No.could be found from the technical param eters. E MODEL MCS(MHS)100.1F MCS(MHS)120.1F MCS(MHS)135.1F MCS(MHS)150/170.1F MCS(MHS)185.1F L Dimension/mm A B C D E H L Water connections 5"(OD139.7) 8"(OD219.1) 8"(OD219.1) 8"(OD219.1) 8"(OD219.1) 1 Condensor 2 Evaporator Fans Evaporator water outlet Evaporator water intlet Control box 51

52 MCS200~380 / MHS200~380 H L 2 3 C B A Dimension/mm A B C D E Note: Fans No.could be found from the technical param eters H L Water connections 8"(OD219.1) 8"(OD219.1) 8"(OD219.1) 8"(OD219.1) Condensor Evaporator Evaporator water outlet Evaporator water intlet Control box 6 Fans unit: mm D E MODEL MCS(MHS)200.2F MCS(MHS)220/235/260.2F MCS(MHS)285/310.2F MCS(MHS)330/350/380.2F 52

53 10. Foundation MCS050~060 / MHS050~060 Installation base Unit base Control box A B Distribution of shock absorber A B Load of spring shock absorber (kg) Unit model A B MCS 050.1/ MHS 050.1/ Unit: mm MCS070~080 / MHS070~080 Installation base Unit base Control box A B Distribution of shock absorber A B Load of spring shock absorber (kg) Unit model A B MCS 070.1/ MHS 070.1/ Unit: mm 53

54 MCS100 / MHS100 Installation base Unit base A B C Control box Distribution of shock absorber A B C Load of spring shock absorber (kg) Unit model A B C MCS MHS Unit: mm MCS120 / MHS120 Installation base Unit base A B C Control box Distribution of shock absorber A B C Load of spring shock absorber (kg) Unit model A B C MCS MHS Unit: mm 54

55 MCS135 / MHS135 Installation base Unit base A B C Control box Distribution of shock absorber A B C Load of spring shock absorber (kg) Unit model A B C MCS MHS Unit: mm MCS150~170 / MHS150~170 Installation base Unit base A B C Control box Distribution of shock absorber A B C Load of spring shock absorber (kg) Unit model A B C MCS150.1/ MHS150.1/ Unit: mm 55

56 MCS185 / MHS185 Installation base Unit base A B C Control box Distribution of shock absorber A B C Load of spring shock absorber (kg) Unit model A B C MCS MHS Unit: mm MCS200 / MHS200 Installation base Unit base A B C D Control box Distribution of shock absorber A B C D Load of spring shock absorber (kg) Unit model A B C D MCS MHS Unit: mm 56

57 MCS220~235 / MHS220~235 Installation base Unit base A B C D Control box Distribution of shock absorber A B C D Load of spring shock absorber (kg) Unit model A B C D MCS MHS MCS MHS Unit: mm MCS260 / MHS260 Installation base Unit base A B C D Control box Distribution of shock absorber A B C D Load of spring shock absorber (kg) Unit model A B C D MCS MHS Unit: mm 57

58 MCS285~310/MHS285~310 Installation base Unit base A B C D Control box Distribution of shock absorber A B C D Unit: mm Load of spring shock absorber (kg) Unit model A B C D MCS MHS MCS MHS MCS330~380/MHS330~380 Installation base Unit base Control box Distribution of shock absorber A B C D E A B C D E Unit: mm Load of spring shock absorber (kg) Unit model A B C D E MCS MHS MCS MHS MCS MHS Note: The unit should be set on a horizontal flat foundation, ground floor or building roof capable of supporting the operating weight of the entire equipment. See Specifications for the operating weight. Levelness of ground base 0.1%. A drainage ditch shall be set around the earth base to prevent water logging, and the foundation shall have smooth edge. The foundation shall have enough strength to support the operating weight of the entire unit (the water piping having counted on the support). A spring damper shall be installed between the unit and the ground base. Set bolts shall not be pre-buried. The model of shock absorber shall be chosen according to the load to be carried, and cannot be exchanged. 58

59 11. Sound Level 11.1 ST Overall Sound Level and Octave Band Level Model MHS/MCS Octave band level Hz Overall dba 050.1FST 060.1FST 070.1FST 080.1FST 100.1FST 120.1FST 135.1FST 150.1FST 170.1FST 185.1FST 200.2FST 220.2FST 235.2FST 260.2FST 285.2FST 310.2FST 330.2FST 350.2FST 380.2FST Notes: Average sound pressure level is according to ISO 3744, semispheric free field conditions. Sound pressure levels are referred to units furnished without hydraulic kit. Measuring location is at 1m from the unit in semispheric free field (rif Pa). 59

60 11.2 LN Overall Sound Level and Octave Band Level Model MHS/MCS Octave band level Hz Overall dba 050.1FLN 060.1FLN 070.1FLN 080.1FLN 100.1FLN 120.1FLN 135.1FLN 150.1FLN 170.1FLN 185.1FLN 200.2FLN 220.2FLN 235.2FLN 260.2FLN 285.2FLN 310.2FLN 330.2FLN 350.2FLN Notes: Average sound pressure level is according to JB/T , semispheric free field conditions. Sound pressure levels are referred to units furnished without hydraulic kit. Measuring location is at 1m from the unit in semispheric free field (rif Pa). 60

61 12. Electric Characteristics 12.1 Wiring Diagram MCS050/060/070/080/100/120/135/150/170/185.1FST2(4) COMPRESSOR POWER SUPPLY FAN POWER SUPPLY 61

62 FAN POWER SUPPLY FAN POWER SUPPLY 62

63 UNIT CONTROL CIRCUIT POWER SUPPLY ELECTRONIC EXPANSION VALVE WIRING DIAGRAM 63

64 CONTROL CIRCUIT WIRING DIAGRAN CONTROL CIRCUIT WIRING DIAGRAN 64

65 CONTROL CIRCUIT WIRING DIAGRAN SYMBOL DESCRIPTION SHEET 65

66 MCS200/220/235/260/285/310/330/350/380.2FST2(4) COMPRESSOR POWER SUPPLY FAN POWER SUPPLY(SYS.1) 66

67 FAN POWER SUPPLY(SYS.2) FAN POWER SUPPLY(SYS.1) 67

68 FAN POWER SUPPLY(SYS.2) UNIT CONTROL CIRCUIT POWER SUPPLY 68

69 ELECTRONIC EXPANSION VALVE WIRING DIAGRAM CONTROL CIRCUIT WIRING DIAGRAM 69

70 CONTROL CIRCUIT WIRING DIAGRAM CONTROL CIRCUIT WIRING DIAGRAM 70

71 SYMBOL DESCRIPTION SHEET 71

72 MHS050/060/070/080/100/120/135/150/170/185.1FST2(4) COMPRESSOR POWER SUPPLY FAN POWER SUPPLY 72

73 FAN POWER SUPPLY FAN POWER SUPPLY 73

74 UNIT CONTROL CIRCUIT POWER SUPPLY ELECTRONIC EXPANSION VALVE WIRING DIAGRAM 74

75 CONTROL CIRCUIT WIRING DIAGRAM CONTROL CIRCUIT WIRING DIAGRAM 75

76 CONTROL CIRCUIT WIRING DIAGRAM CONTROL CIRCUIT WIRING DIAGRAM 76

77 SYMBOL DESCRIPTION SHEET 77

78 MHS200/220/235/260/285/310/330/350/380.2FST2(4) COMPRESSOR POWER SUPPLY FAN POWER SUPPLY(SYS.1) 78

79 FAN POWER SUPPLY(SYS.2) FAN POWER SUPPLY(SYS.1) 79

80 FAN POWER SUPPLY(SYS.2) UNIT CONTROL CIRCUIT POWER SUPPLY 80

81 ELECTRONIC EXPANSION VALVE WIRING DIAGRAM CONTROL CIRCUIT WIRING DIAGRAM 81

82 CONTROL CIRCUIT WIRING DIAGRAM CONTROL CIRCUIT WIRING DIAGRAM 82

83 CONTROL CIRCUIT WIRING DIAGRAM SYMBOL DESCRIPTION SHEET 83

84 12.2 Electrical Data Model MHS/MCS Unit Volts-Ph-Hz Voltage range Starting Comp.(each) Fan motor(each) Unit Qty. LRA MFA Qty. kw FLA MRA RLA Inrush Amps 050.1FST2/ FST FST2/ FST FST2/ FST FST2/ FST FST2/ FST FST2/ FST FST2/ FST FST2/ FST FST2/ FST FST2/ FST FST2/ FST FST2/ FST FST2/ FST FST2/ FST FST2/ FST FST2/ FST FST2/ FST FST2/ FST /3N/50Hz Max.440V Min.342V Star-Delta 380.2FST Notes: LRA -- Locked rotor Amps in Delta for each compressor. MFA -- Max. Fuse Amps for each compressor. FLA -- Full Load Amps for each fan motor. MRA -- Max. Running Amps for unit (based on outdoor temp. 44 C) leaving water temp.15 C. RLA -- Rated load Amps for unit (based on outdoor temp. 35 C) leaving water temp.15 C. Inrush Amps -- Single System: Compressor inrush current + Control circuit current. Dual System: Inrush current of Max. size compressor running current of small size compressor (based on outdoor temp. 44 C) + Fan current + Control circuit current. The size of power cable and breaker is recommended larger than MRA, ensuring the breaker doesn't trip off while the chiller is starting. 84

85 13. System Diagram 13.1 Cooling System 13.2 Heating pump system 85

86 14. Installation 14.1 Location of Water Circulating Pump If locations of a pump and an expansion tank are wrong, air is intermixed into the chilled water system, which may reduce capacity of the water chiller and cause abnormal noise. Be sure to install the pump on. 86

87 Air Cooled Single Screw Chiller 14.2 Moving and Lifting Please perform the following checks before lifting No. Check items and requirements Treatment when not conformed 1 Lifting safety measure must in compliance with local laws and regulations. Add the proper safety measure as required. 2 Lifting must be performed in accordance with this Manual. Do it as required. 3 Avoid bumping and/or jolting during unloading from the lorry and moving Add more equipment to avoid bumping. the machine. 4 Prohibit staying under the crane or machine during lifting. Follow the lifting regulations. 5 Add some insulation between the lifting ropes and machine to avoid Add more equipment to avoid scraping. scraping Lifting method Use proper Lifting method: Please use spreader bar and the lifting holes of the machine when lifting to avoid damage to the equipments. The hoisting belt (such as tight wire, nylon)should be twice and not shorter than ten meters(or four not shorter than five meters),and both sides of pole should be extended over 100mm out of unit in order to prevent the hoisting belt from damaging unit. (Refer to the figure) MHS/MCS050~200 lifting figure The increase of length and weight of MHS220~380 units bring a lot of difficulties to hoisting work. The number of lifting ropes and holes which used for units can be according to actual needs. (Refer to the figure) MHS/MCS220~380 lifting figure It is necessary that the unit maintain a level when being hoisted. Tilt angle should be less than 15 degrees, otherwise the unit may be overturned. 87

88 14.3 Refer to the following items if the units are installed where there s plenty of snow: Don t install the unit under the eaves. Incorrect Correct Correct way to lift Elevate the installation height of the unit( unit base is recommended 1m higher than the highest accumulated snow.) Snow accumulation size Snow accumulation size Incorrect Correct Don t install unit at places where snow will be accumulated. Incorrect 88

89 14.4 When two or more units are positioned side by side, it s recommended that follow the below figure to do the installation: Lateral layout Lengthways layout

90 14.5 Hydraulic System Installation After the unit installation, the piping installation begins. It s advised to follow the installation regulation so that installation of hydraulic system is efficient. There should be no dust in the piping. All the piping should follow the local regulation and rules. Since the bends, three-way joints and valves will affect the performance of water pump, all piping should be as straight and simple as possible; It is recommended to apply manual shut-off valve on all piping for maintenance; Draining pipe should be installed at the lowest point of water circuit in order to drain out the evaporator and pipeline; Air relief valve should be installed at the highest point of water circuit in order to remove the air from hydraulic system. Thermal insulation is not needed for draining pipe and air relief valve for easy service; According to the requirement of the project, the design of evaporator should follow the items below: 1) The outlet of the pump should be connected with the inlet of the evaporator. The inlet of the pump should be entering water tube, not evaporator 2) A more than 25 meshes strainer must be installed at the inlet of evaporator. 3) The chilled water pipe must be cleaned completely by bypass. It s prohibited to use shell and tube evaporator to clean the pipe. 4) It is recommended that thermometer and pressure gauge be installed at the inlet and outlet of water exchangers for easy service. 5) Chilled water pipe outdoor should be covered with electric heater, and with heat insulation to prevent freezing or dew under low temperature. 6) A flow switch must be applied at the outlet of evaporator. The minimum length of straight pipeline on both sides of flow switch should be more than five times of pipe diameter. Warning: Water flow can't be used for Switch ON/OFF. It s a safety switch. 90

91 15. Guide Specifications General Before shipment a full test will be held to avoid any losses. Chiller will be delivered to the job site completely assembled and charged with refrigerant and oil. Comply with the manufacturer instructions for rigging and handling equipment. The unit will be able to start up and operate as standard at full load and outside air temperature from C to C with an evaporator leaving fluid temperature between C and 15 C. Performance Number of unit: Cooling capacity for single air-cooled water chiller: kw Power input for single air-cooled water chiller: kw Evaporator entering water temperature: C Evaporator leaving water temperature: C Evaporator water flow: L/min Outside working ambient temperature: C The unit should work with electricity at V ±10%, 3ph, 50Hz without neutral and shall only have one power connection point. The control circuit voltage shall be 24V maximum, supplied by a factoryinstalled transformer. The electrical power absorbed should not exceed kw Unit description Each chiller consists of multiple semi-hermetic rotary screw compressor, direct expansion shell & tube evaporator, air-cooled condenser section, control system and all components necessary for safety. The units will have 2 independent refrigerant circuits, and the respective electronic microprocessor will allow the starting of the compressors. Each chiller will be factory assembled on a robust base-frame made of zinc coated steel, protected by an epoxy paint. Noise level and vibrations Sound pressure level at 1 meter distance in free field, semispheric conditions, shall not exceed db(a). The sound pressure levels must be rated in accordance to ISO Other types of rating are unacceptable. Vibration level should not exceed 2mm/s. Dimensions Unit dimensions shall not exceed following indications: Unit length mm Unit width mm Unit height mm Compressors The compressors shall be field serviceable, semi-hermetic, single-screw type with one main helical rotor meshing with gate-rotor. The gate-rotor will be constructed of a carbon impregnated engineered composite material. The gate-rotor supports will be constructed of cast iron. The compressor shall be provided with an automatic spring return of capacity control valve to the minimum load position to ensure compressor starting always at minimum motor load, with minimum inrush current. The oil injection shall be used in order to get high EER (Energy Efficiency Ratio) also at any load conditions. Refrigerant system differential pressure shall provide oil flow through service replaceable, and cartridge type oil filter internal to compressor. Refrigerant system differential pressure shall provide oil injection on all moving compressor parts to correctly lubricate them. The compressor's oil cooling must be realized, when necessary, by liquid injection. External dedicated heat exchanger and additional piping to carry the oil from the compressor to heat exchanger and vice versa will be not accepted. The compressor shall be provided with an integrated, high efficiency, cyclonic type oil separator and with built-in oil filter. The compressor shall be direct electrical drive ( Hz), without gear transmission between 91

92 the screw and the electrical motor. The motor's compressor shall be provided with star/delta start (D/Y) as standard. The compressor casing shall be provided with ports to realize refrigerant economizer actions. Shall be present two thermal protections realized by temperature sensors: one is to protect motor temperature and the other against high discharge gas temperature. The compressor shall be equipped with an electric oil-crankcase heater. Regulation of cooling capacity Each unit will have a microprocessor for the control of compressor slide valve's position. The capacity control shall modulate slide valve's capacity from 100% to 25% for each compressor (from 100% down to 12,5% of full load for unit with 2 compressors). The chiller shall be capable of stable operation to a minimum of 12,5% of full load, without hot gas bypass. Step unloading unacceptable because of evaporator leaving water temperature fluctuation and low compressor's efficiency at partial load. The system shall stage the unit based on the leaving evaporator water temperature that shall be controlled by a PID (Proportional Integral Derivative) loop. Evaporator The units shall be supplied with shell and tubes counter-flow evaporator with single pass refrigerant. It will be refrigerant direct expansion type with refrigerant inside the tubes and water outside (shell side). It will include carbon steel tube sheets, with straight copper tubes internally wound for higher efficiencies, expanded on the tube plates. The external shell shall be linked with an electrical heater to prevent freezing down to -15 C ambient temperature, commanded by a thermostat and shall be insulated with flexible, closed cell polyurethane insulation material (20mm thick). The evaporator will have 2 circuits, one for each compressor and shall be single refrigerant pass. The water connections shall be VICTAULIC type connections as standard to ensure quick mechanical disconnection between the unit and the hydraulic network. Condenser coil The condenser coils are constructed with internally finned seamless copper tubes of a "W" shape and arranged in a staggered row pattern and mechanically expanded into lanced and rippled aluminum fins with full fin collars for higher efficiencies. The space between the fins are given by a collar that will increase the surface area in connection with the tubes, protecting them from ambient corrosion. The coils will have an integral sub cooler circuit that provides sufficient sub cooling to effectively eliminate the possibility of liquid flashing and increase the unit's efficiency of 5-7% without increasing in power absorption. The condenser coil shall be leak-tested and submitted to a pressure test with dry air. The total coil surface area will be designed in order to have an air velocity not higher than 3.05m/sec. Condenser fans The fans used in conjunction with the condenser coils, shall be helical type with aerofoil blades for higher efficiencies and lower noise. Each fan shall be protected by a fan guard. The air discharge shall be vertical and each fan must be coupled to the electrical motor, supplied as standard to IP54 and capable to work to ambient temperatures of -40 C to +55 C. They shall have individual overload protection via a disconnect switch. Refrigerant circuit The unit must have refrigerant circuits completely independent of each other with one compressor per circuit. Each circuit shall include: thermostatic expansion device, compressor discharge shut-off valve, a liquid line shut-off valve with charging connection, replaceable core filter-drier, sight glass with moisture indicator and insulated suction line. Suction line shut-off valve should be available as option. 92

93 Condensing pressure control The units will be provided with an automatic control for condensing pressure, ensuring a proper condensing pressurethe. Fan speed control, allows unit's operation with very low ambient temperature down to -15 C. Automatic compressor unloading, prevents the shutdown of the refrigerant circuit (shutdown of the unit) due to a high-pressure fault. Control panel Unit control system should be centrally located in an electric panel (IP 54). Power and controls should be separated and operating in different compartments of the same panel. Compressor contactor sequence will be star/delta type. Power and starting controls should include fuses and contactors for each compressor motor coil and fan motors. Operating and safety controls should include energy saving control; emergency stop switch; overload protection for compressor motor; high and low pressure cutout switch (for each refrigerant circuit); anti-freeze thermostat; shut off switch for each compressor. All of the information regarding the unit will be reported on a display and with the internal built-in calendar and clock that will switch the unit ON/OFF during day time all year long. The following features and functions shall be included: Chilled water temperature reset, controlled from the return water temperature or through a remote 4-20 ma DC signal or external ambient temperature; Soft load function to prevent the system from operating at full load during the chilled fluid pull down period; Password protection of critical parameters; Start-to-start and stop-to-star timers to provide minimum compressor off-time with maximum motor protection; Communication capability with a PC or remote monitoring; Discharge pressure control through intelligent cycling of condenser fans; Lead-lag selection by manual or automatically by circuit based on run hours; Double set point for glycol unit version; Scheduling via internal time clock to allow programming of a yearly start-stop schedule accommodating weekends and holidays. Display Capabilities The controller as a minimum shall be capable of monitoring and displaying the following data: No. Analogue Inputs (AI) No. Digital Inputs (DI) 1 E ntering Evaporator fluid Temp. 1 Control switch one per comp. 2 Leaving Evaporator fluid Temp. 2 Evaporator water flow switch 3 Outside Air Temp. 3 Phase monitor 4 Not used 4 Double Set point (Ice Mode) 5 Discharge Press., one per comp. 5 High Press. Switch, one per compressor 6 Discharge Press., one per comp. 6 High Press. Switch, one per compressor 7 S etpoint Override (Set point Reset) 7 Low Press. Switch, one per compressor 8 Demand Limit or Current Limit (Site Selectable) 8 Oil Press. Switch, one per compressor 9 % Capacity Signal, one per comp. 9 Transition Fault, one per compressor 10 % Capacity Signal, one per comp. 10 Discharge Temp. Sensor, one per comp. 11 External Alarm 93

94 2014 McQuay International +1 (800) While utmost care is taken in ensuring that all details in the publication are correct at the time of going to press, we are constantly striving for improvement and therefore reserve the right to alter model specifications and equipment without notice. Details of specifications and equipment are also subject to change to suit local conditions and requirements and not all models are available in every market.

Inverter air to water heat pumps

Inverter air to water heat pumps Product Manual 504 B 07/07 A EN Date: July 2007 Supersedes: none Inverter air to water heat pumps McEnergy HPI 067.2 104.2 Cooling capacity from 249 to 385 kw Heating capacity from 274 to 412 kw Refrigerant:

More information

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw Air-to-Water Reverse Cycle Heat Pumps SLH 1202 to 3804 With Screw Compressors 261 to 775 kw 287 to 853 kw Technical Brochure TM SLH-A.2GB Date : November 2004 Supersedes : TM SLH-A.1GB/05.04 Design Features

More information

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw Air-to-Water Reverse Cycle Heat Pumps VLH 504 to 1204 126 to 294 kw 133 to 307 kw Technical Brochure TM VLH-N.3GB Date : June 2005 Supersedes : TM VLH-N.2GB/07.04 Specifications Advantages Range extension

More information

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75.

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75. Chiller AQL/ to 75 Air Cooled Water Chillers Only and Heat Pump Engineering Data Manual.0 to 75.8 kw 39.9 to 77.2 kw Outstanding Strength Points R410A Refrigerant. New simpler refrigerant circuit layout.

More information

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07. Air Cooled Water Chillers CLS 182 to 602 41 to 150 kw Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.04 R Specifications General characteristics The CLS air cooled water

More information

Chiller. SWS/SWR 1602 to Water Cooled Chillers Cooling Only and Condenserless Versions Engineering Data Manual.

Chiller. SWS/SWR 1602 to Water Cooled Chillers Cooling Only and Condenserless Versions Engineering Data Manual. Chiller SWS/SWR 1602 to 4802 Water Cooled Chillers Only and Condenserless Versions Engineering Data Manual 272 to 1118 kw Specifications General The SWS water cooled screw chillers are equipped with high

More information

PRK PREVIEW. System. OZONE FRIENDLY R-407C Series. Inverter Heat Pump Series Heat Recovery Series PLUS Series (Heat Pump)

PRK PREVIEW. System. OZONE FRIENDLY R-407C Series. Inverter Heat Pump Series Heat Recovery Series PLUS Series (Heat Pump) PRK 00-04 PREVIEW System OZONE FRIENDLY R-407C Series Inverter Heat Pump Series Heat Recovery Series PLUS Series (Heat Pump) 3DUW#4 2XWGRRU#8QLWV 111111111111111111111111111111111111111111111111111111111111111111111

More information

CONTINUOUS CAPACITY CONTROL MODELS

CONTINUOUS CAPACITY CONTROL MODELS This series of air-cooled water chillers up to 400HP has been developed for various requirements of air conditioning systems and industrial chilled water systems, where these equipments are operated under

More information

SeasonPak Packaged Air-Cooled Water Chiller

SeasonPak Packaged Air-Cooled Water Chiller Installation Manual IM 676 Group: Chiller Part Number: 594920Y Date: July 1996 Supersedes: None SeasonPak Packaged Air-Cooled Water Chiller Models ALR 032E Through 185E 1996 McQuay International Table

More information

VLS (Cooling Only) VLH (Heat Pump Version) VLR (Total Heat Recovery Version)

VLS (Cooling Only) VLH (Heat Pump Version) VLR (Total Heat Recovery Version) R u Air Cooled Water Chillers VLS (Cooling Only) VLH (Heat Pump Version) VLR (Total Heat Recovery Version) Models 524 to 1204 137 to 308 kw 150 to 336 kw Engineering Data Manual EDM VL410-W.2GB Date :

More information

McQuay International WMC New Water Cooled Chiller with oil free centrifugal compressors

McQuay International WMC New Water Cooled Chiller with oil free centrifugal compressors McQuay International WMC New Water Cooled Chiller with oil free centrifugal compressors Applied Systems - Strategic Marketing Contents 1. Introducing WMC 1.1 Product Overview 2010 1.2 Range 2. Technical

More information

AIR COOLED CHILLERS WATER COOLED CHILLERS

AIR COOLED CHILLERS WATER COOLED CHILLERS AIR COOLED CHILLERS WATER COOLED CHILLERS STANDARD UNIT SPECIFICATIONS OF COMMERCIAL AIR COOLED CHILLERS General Description & Assembly Air Cooled Chillers are commercial packaged systems complete with

More information

Air-Cooled Liquid Chiller with integrated hydraulic module

Air-Cooled Liquid Chiller with integrated hydraulic module Air-Cooled Liquid Chiller with integrated hydraulic module Cooling only: CGAN 200-250 - 300-400 - 450-490 - 500-600 - 700-800 - 900-925 Reversible: CXAN 200-250 - 300-400 - 450-490 - 500-600 - 700-800

More information

Index Features and advantages... 3 General characteristics... 5 Nomenclature Technical specifications... 11

Index Features and advantages... 3 General characteristics... 5 Nomenclature Technical specifications... 11 Index Features and advantages... 3 Low operating cost... 3 Low operating sound levels... 3 Excellent serviceability... 3 Proven reliability... 3 Infinite capacity control... 3 Superior control logic...

More information

Chiller. AQSL 2612 to Air Cooled Chillers With or without total heat recovery Engineering Data Manual. 602 to 908 kw

Chiller. AQSL 2612 to Air Cooled Chillers With or without total heat recovery Engineering Data Manual. 602 to 908 kw Chiller AQSL 2612 to 4212 Air Cooled Chillers With or without total heat recovery Engineering Data Manual 602 to 908 kw Features & Strength Points Sturdy structure, vibration tests and FEM structural analysis.

More information

Reversible air-to-water scroll heat pumps

Reversible air-to-water scroll heat pumps Reversible air-to-water scroll heat pumps Model CXAO 120 to 290 Cooling capacity: 420-1030 kw Heating capacity: 475-1175 kw CG-PRC027A-GB Table of Contents Model number description...4 Technical specifications...5

More information

Chiller. VLC 524 to Air Cooled Condensing Units Engineering Data Manual. 154 to 347 kw

Chiller. VLC 524 to Air Cooled Condensing Units Engineering Data Manual. 154 to 347 kw Chiller VLC 524 to 1204 Air Cooled Condensing Units Engineering Data Manual 154 to 347 kw Outstanding Strength Points Units with R410A refrigerant (it will be the real replacement of R22). As near azeotropic

More information

SCROLL - AIR COOLED PACKAGED & SPLIT SYSTEM ICE CHILLERS

SCROLL - AIR COOLED PACKAGED & SPLIT SYSTEM ICE CHILLERS SCROLL - AIR COOLED PACKAGED & SPLIT SYSTEM ICE CHILLERS 1 to 40 Nominal Tons Rev-01 TABLE OF CONTENTS Page: Description 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Product Nomenclature Air Cooled Chiller

More information

AQWL/AQWH/AQWR 1404 to 2406

AQWL/AQWH/AQWR 1404 to 2406 Chiller AQWL/AQWH/AQWR 1404 to 2406 Air Cooled Water Chillers Only, Heat Pump and Total Heat Recovery Engineering Data Manual 380 to 634 kw 418 to 702 kw Features & Strength Points A more "slim and light"

More information

AQVSL/AQVSH STAR 85 to 140

AQVSL/AQVSH STAR 85 to 140 Chiller QVSL/ STR 85 to 140 ir Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual 82 to 157 kw 83 to 168 kw Outstanding Strength Points Units with R410 refrigerant (it will be the

More information

Chillers. EWAD-C- 620~1860 kw. Air-cooled R-134a. » Wide capacity range (620 kw kw) » Multiple efficiency and sound versions

Chillers. EWAD-C- 620~1860 kw. Air-cooled R-134a. » Wide capacity range (620 kw kw) » Multiple efficiency and sound versions Chillers Air-cooled R-134a» Wide capacity range (620 kw - 1860 kw)» Multiple efficiency and sound versions» Unique single screw compressor» Best-in-class energy efficiency (EER up to 3.70 and ESEER up

More information

Air-Cooled Rotary Screw Chillers

Air-Cooled Rotary Screw Chillers Product Manual PM ALS-4 Group: Chiller Date: January, 2001 Supersedes: PM ALS-3 Air-Cooled Rotary Screw Chillers Models ALS 141C to ALS 420C 120 to 420 Tons, 420 to 1470 kw HCFC-22 60 Hz Table of Contents

More information

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO technical sales guide - 60Hz Taurus R Ducted Split Units UPTO HIGH AMBIENT OPERATION 52 O C Page CONTENTS Nomenclature.. 2 Description. 3 Features.. 3 Product Data. 4 Condensing Unit Cooling Performance

More information

Air-Cooled Screw Compressor Chiller

Air-Cooled Screw Compressor Chiller Installation, Operation and Maintenance Manual IOMM ALS Group: Chiller Part Number: 070774401 Date: February 1998 Supersedes: IM 548-3 Air-Cooled Screw Compressor Chiller ALS 070A through 425A 60 Hertz

More information

HYDROCIAT LW. Use. Range. Water-cooled chillers. Screw compressors CIAT shell and tubes direct expansion evaporator HPS (High Power System) equipment

HYDROCIAT LW. Use. Range. Water-cooled chillers. Screw compressors CIAT shell and tubes direct expansion evaporator HPS (High Power System) equipment Screw compressors CIAT shell and tubes direct expansion evaporator (High Power System) equipment Cooling capacity: 370 to 1 170 kw Heating capacity: 500 to 1 400 kw Heating Cooling Heat recovery Use The

More information

TWA S/K/P. Incorporating. R410A Air cooled water chillers with axial fans and scroll compressors from 189 kw to 1007 kw

TWA S/K/P. Incorporating. R410A Air cooled water chillers with axial fans and scroll compressors from 189 kw to 1007 kw TWA 212-1102 S/K/P Incorporating R410A Air cooled water chillers with axial fans and scroll compressors from 189 kw to 1007 kw The complete solution to all your cooling needs TWA 212-1102 S/K/P Index

More information

Product Catalog TSE Series Scroll Central Chillers

Product Catalog TSE Series Scroll Central Chillers Product Catalog TSE Series Scroll Central Chillers Contents Features...1 Available Options...3 Hot Gas Bypass Valve... 3 Rotary Non-Fused Disconnect Switch... 3 Integral Reservoir and Pumping System...

More information

UMXCA/UMXCBA ECVA/ECVBA

UMXCA/UMXCBA ECVA/ECVBA OUTDOOR UNITS Models: 801.1 1001.1 1201.1 1501.1 1602.2 2002.2 2402.2 3002.2 3502.2 4002.2 4502.2 Cooling Capacities: from 25,9 kw to 134,7 kw Heating Capacities: from 27,3 kw to 142,4 kw INDOOR UNITS

More information

technical catalogue tetris KW Chiller and heat pumps air/water

technical catalogue tetris KW Chiller and heat pumps air/water technical catalogue tetris 110 930 KW Chiller and heat pumps air/water > TETRIS Water chiller > TETRIS /HP Reversible heat pump > TETRIS /ST Water chiller with storage tank and pumps > TETRIS /DC Unit

More information

Twin Screw Compressor Type HITACHI Water Cooled Water Chillers [H] SERIES

Twin Screw Compressor Type HITACHI Water Cooled Water Chillers [H] SERIES Twin Screw Compressor Type HITACHI Water Cooled Water Chillers [H] SERIES Nominal Cooling Capacity Range R22: 139.5 kw 1825 kw 119,970kcal/h 1,569,500kcal/h 39.7 RT 519.1 RT R407C: 130 kw 1755 kw 111,800kcal/h

More information

Concealed Ducted Split Series R22

Concealed Ducted Split Series R22 Concealed Ducted Split Series R22 24-60 MBH Ducted Split with Hermetic Compressor Tropical 50 Hz For more technical information please visit Table of Contents INTRODUCTION 2 NOMENCLATURE 2 UNIT RATING

More information

Product Catalog TSE Series Scroll Central Chillers

Product Catalog TSE Series Scroll Central Chillers Product Catalog TSE Series Scroll Central Chillers Contents Features...1 Hot Gas Bypass Valve... 2 Rotary Non-Fused Disconnect Switch... 2 Integral Reservoir and Pumping System... 3 Remote Condenser Coil

More information

AQVL (Cooling Only Version) AQVH (Heat Pump Version)

AQVL (Cooling Only Version) AQVH (Heat Pump Version) R u Air Cooled Water Chillers (Cooling Only Version) (Heat ump Version) Models 85 to 140 84 to 137 kw 92 to 146 kw Engineering Data Manual EDM AQV-W.1GB Date : November 2009 Supersedes : None High erformance

More information

SARAVEL PACKAGED AIR-COOLED CONDENSING UNIT

SARAVEL PACKAGED AIR-COOLED CONDENSING UNIT CAT--2006(0) SARAVEL PACKAGED AIR-COOLED CONDENSING UNIT 10 TO 100 TONS ( 35 TO 350 kw ) TABLE OF CONTENTS 2 Introduction... 3 Specifications 4 Examples.... 6 Physical Data.... 8 Rating Tables....... 10

More information

Section 5 AIR - COOLED CONDENSING UNITS MODEL PC 05Z TO PC NOMINAL COOLING CAPACITY RANGE 56.6 TO 772 MBH

Section 5 AIR - COOLED CONDENSING UNITS MODEL PC 05Z TO PC NOMINAL COOLING CAPACITY RANGE 56.6 TO 772 MBH AIR - COOLED CONDENSING UNITS MODEL PC 05Z TO PC 80-01 NOMINAL COOLING CAPACITY RANGE 56.6 TO 772 MBH 14 FEATURES MODEL PC 05Z TO PC 30-02 CABINET: Cabinets are constructed of heavily zinc coated galvanized

More information

ACPSE-P Series 50Hz 410A. Rooftop Units Cooling Capacity : 26 to 1388 MBH (8 to 407 kw) Heating Capacity : 28 to 1298 MBH (8 to 380 kw)

ACPSE-P Series 50Hz 410A. Rooftop Units Cooling Capacity : 26 to 1388 MBH (8 to 407 kw) Heating Capacity : 28 to 1298 MBH (8 to 380 kw) -P Series 50Hz Rooftop Units Cooling Capacity : to 388 MBH (8 to 407 kw) Heating Capacity : 8 to 98 MBH (8 to 380 kw) 40A Products that perform...by people who care NOMENCLATURE AC P S E 435 P HP G Q Air

More information

PACKAGED LIQUID CHILLER 6. HUMIDIFIER SECTIONS. C Member. Liquid Chiller. nowlc And noalc Series

PACKAGED LIQUID CHILLER 6. HUMIDIFIER SECTIONS. C Member. Liquid Chiller. nowlc And noalc Series 6. HUMIDIFIER SECTIONS Liquid Chiller nowlc And noalc Series C Member 1 Features and Benefits OMRAN cold generator reciprocating Liquid chiller are designed and built to provide reliable,efficient performance

More information

Product Catalog. NQ Series. Portable and Remote Air-Cooled Condenser Chillers 4 to 43 Tons

Product Catalog. NQ Series. Portable and Remote Air-Cooled Condenser Chillers 4 to 43 Tons Product Catalog NQ Series Portable and Remote Air-Cooled Condenser Chillers 4 to 43 Tons Page Intentionally Blank Contents Standard Features...1 Available Options...3 Oversized Pumps... 3 High Flow Unit

More information

Table of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10

Table of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10 Table of Contents Page No. 1. Model Designation And Unit Models 1 2. Features 2 3. Guide Specifications 4 4. Standard Unit Components 5 5. Technical Data 6 6. Performance Data 10 7. Electrical Data 19

More information

D M S 760 C01 A A 1 1

D M S 760 C01 A A 1 1 CONTENTS Description Features Options Available Selection Method Product Data Cooling Performance Data (85 F Ambient Cooling Performance Data (95 F Ambient) Cooling Performance Data (105 F Ambient)..............................

More information

High efficiency industrial type semi-hermetic twin helical screw compressor.

High efficiency industrial type semi-hermetic twin helical screw compressor. YCAS AIR COOLED SCREW CHILLER R407C REFRIGERANT COOLING CAPACITIES 260 kw to 1194 kw The YCAS range of chillers are designed for water or water-glycol cooling. Models are available with 2, 3 and 4 refrigerant

More information

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Single stage cooling capacity control on all 0 241 models Two stage cooling capacity control on

More information

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS 550.13-TG1Y(98) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS HCA300, 360, 80 & 600 5 THRU 50 NOMINAL TONS HCA80 DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece

More information

HYDROCIAT LW R134a. Water cooled chillers USE RANGE

HYDROCIAT LW R134a. Water cooled chillers USE RANGE Screw compressors CIAT direct expansion shell and tubes evaporator equipment (High Power System) Cooling or heating Heat recovery ENVIRONMENTALLY HFC R134a PROTECTION DE FRIENDLY L'ENVIRONNEMENT Cooling

More information

Compresseur scroll. Refrigerant R410A SYSAQUAC. Air Cooled Condensing Units Models 25 to to 136.0kW

Compresseur scroll. Refrigerant R410A SYSAQUAC. Air Cooled Condensing Units Models 25 to to 136.0kW Compresseur scroll Refrigerant R410A SYSAQUAC Air Cooled Condensing Units Models 25 to 125 32.0 to 136.0kW SYSAQUA Condensation 1 Key Points R410A refrigerant, Units are optimized for partial load operation,

More information

CATÁLOGO TÉCNICO COMERCIAL

CATÁLOGO TÉCNICO COMERCIAL CATÁLOGO TÉCNICO COMERCIAL ENFRIADORAS DE AGUA CONDENSADAS POR AIRE Series LCAEX De 350 a 1600 Kw. Compresor de tornillo R-134A Index Identification code Identification code and index... pag. 2 General

More information

CGA CXA VGA VXA CG-PRC006-E4

CGA CXA VGA VXA CG-PRC006-E4 Cooling Only or Reversible Air Cooled Water Chiller CGA 075-100-120-150-200-240 CXA 075-100-120-150-200-240 VGA 075-100-120-150-200-240 VXA 075-100-120-150-200-240 Designed with your needs in mind TRANE

More information

HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM

HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM 1 Lmf Clima 216 FERRARO GROUP HPR Heat recovery units HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM from 7 to 23. m³/h Supporting structure in extruded aluminium profiles and curtain

More information

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS R FORM NO: MS0305F Products That Perform...By People Who Care AIR - COOLED SPLIT SYSTEM AIR CONDITIONERS WITH SCROLL COMPRESSORS 50 Hz COOLING CAPACITY- 60 MBH TO 1360 MBH ACCS SERIES HEB-D, EB-D SERIES

More information

30GX AIR-COOLED LIQUID CHILLER

30GX AIR-COOLED LIQUID CHILLER 30GX-4SB 30GX080-265 AIR-COOLED LIQUID CHILLER PERFORMANCE DATA FIELD WIRING DIAGRAM 1997 Carrier Corporation Syracuse, New York 13221 Form 30GX-4SB Supersedes 30GX-3SB Printed in U.S.A. 12-97 Catalog

More information

CWP-CO / CWP-RC / CWP-HP 02 to 35

CWP-CO / CWP-RC / CWP-HP 02 to 35 Water Cooled Water Chillers Cooling Only, Condenserless and Heat Pump Versions - / - / - 02 to 35 8 to 136 9 to 164 Technical Brochure TM -N.4GB Date : March 2006 Supersedes : TM -N.3GB/05.04 Technical

More information

PRODUCT CATALOGUE CHILLER ECOMAX

PRODUCT CATALOGUE CHILLER ECOMAX PRODUCT CATALOGUE CHILLER ECOMAX English/02-2005 AIR COOLED CHILLER INTRODUCTION TO THE RANGE The simple and robust design of the Ecomax range brings real benefits in terms of savings in investment, operation

More information

30GX AIR-COOLED LIQUID CHILLER

30GX AIR-COOLED LIQUID CHILLER 30GX-5SB 30GX080-265 AIR-COOLED LIQUID CHILLER PERFORMANCE DATA FIELD WIRING DIAGRAM 1998 Carrier Corporation Syracuse, New York 13221 Form 30GX-5SB Supersedes 30GX-4SB Printed in U.S.A. 5-98 Catalog No.

More information

10AC DIPLOMAT SERIES RFC SYSTEMS

10AC DIPLOMAT SERIES RFC SYSTEMS 10AC DIPLOMAT SERIES CONDENSING UNITS RFC SYSTEMS 10.05 to 10.55 SEER *11,100 to 60,000 Btuh (3.3 to 17.6 ) 1 thru 5 Tons (3.5 to 17.6 ) *ARI and DOE Certified Ratings CONDENSING ENGINEERING UNITS DATA

More information

CWP. Cooling Only Version (CO) Condenserless Version (RC) Heat Pump Version (HP) Models 02 to 35. Engineering Data Manual. Water Cooled Water Chillers

CWP. Cooling Only Version (CO) Condenserless Version (RC) Heat Pump Version (HP) Models 02 to 35. Engineering Data Manual. Water Cooled Water Chillers Engineering Data Manual Water Cooled Water Chillers Cooling Only Version () Condenserless Version () Heat Pump Version () Models 02 to 35 8 to 136 9 to 164 N IRWELL GROUP MPNY Specifications General The

More information

OMEGA V ECHOS Water/water cooled chillers and heat pumps kw

OMEGA V ECHOS Water/water cooled chillers and heat pumps kw Water/water cooled chillers and heat pumps 172 1527 kw General information Water-cooled water chillers with hermetic screw compressors and tube bundle heat exchangers. Designed for installation indoors.

More information

Air Cooled CAPACITY: TR CHILLER PRODUCT DATA BOOK

Air Cooled CAPACITY: TR CHILLER PRODUCT DATA BOOK Air Cooled CHILLER CAPACITY: 25-206 TR 2 Company Business Awal Gulf Manufacturing, located at Bahrain is the one of the leading manufacturers of air conditioning and refrigeration products in Middle East

More information

HS18 HS18 SERIES CONDENSING UNITS EXPANSION VALVE AIR CONDITIONING SYSTEM. 3.6 to 16.0 kw ( to Btuh) Cooling Capacity ENGINEERING DATA

HS18 HS18 SERIES CONDENSING UNITS EXPANSION VALVE AIR CONDITIONING SYSTEM. 3.6 to 16.0 kw ( to Btuh) Cooling Capacity ENGINEERING DATA ENGINEERING DATA ENGINEERING DATA MATCHED CONDENSING REMOTE SYSTEMS UNITS 50hz HS18 SERIES CONDENSING UNITS EXPANSION VALVE AIR CONDITIONING SYSTEM 3.6 to 16.0 kw (12 200 to 54 700 Btuh) HS18 Bulletin

More information

ROGERS MACHINERY COMPANY, INC

ROGERS MACHINERY COMPANY, INC KOBELCO KNW SERIES Sample Specifications AIR-COOLED, OIL-FREE AIR COMPRESSOR Frame 0, 1, 2 50 500 HP ROGERS 2110_KA.doc Effective: 03-24-17 Supersedes: 04-06-15 Page 1 of 9 1. SPECIFICATIONS SCOPE 1.1

More information

Product Data. Features/Benefits. 30GUN,GUR Air-Cooled Reciprocating Liquid Chillers (HFC-134a) with ComfortLink Controls 50/60 Hz

Product Data. Features/Benefits. 30GUN,GUR Air-Cooled Reciprocating Liquid Chillers (HFC-134a) with ComfortLink Controls 50/60 Hz Product Data 30GUN,GUR Air-Cooled Reciprocating Liquid Chillers (HFC-134a) with ComfortLink Controls 50/60 Hz Nominal Capacities: 25 to 280 Tons 88 to 985 kw Features/Benefits ComfortLink control Your

More information

Remote Air Cooled Condenser

Remote Air Cooled Condenser Catalog KM-KDS-0313A UniCon Remote Air Cooled Condenser Kramer s Remote Air Cooled Condensers are designed to provide a wide array of solutions focusing on performance, energy efficiency, reduced sound

More information

ROGERS MACHINERY COMPANY, INC

ROGERS MACHINERY COMPANY, INC KOBELCO KNW SERIES Sample Specifications ROGERS MACHINERY COMPANY, INC WATER-COOLED, OIL-FREE AIR COMPRESSOR Frame 00 20-50 HP 2110_00.doc Effective: 03/24/17 Supersedes: 10-11-13 Page 1 of 8 1. SPECIFICATION

More information

R-22, 13 SEER 60 Hertz

R-22, 13 SEER 60 Hertz TECHNICAL GUIDE R-22, 13 SEER 60 Hertz Description These UPG packaged cooling/heating air conditioners are designed for outdoor installation. Only utility and duct connections are required at the point

More information

WQL/WQH/WQRC 524 to 1204

WQL/WQH/WQRC 524 to 1204 Chiller / Close control / Water terminals WQL/WQH/WQRC 524 to 1204 Water Cooled Water Chillers Cooling Only, Heat Pump and Condenserless Versions Engineering Data Manual 155 to 30 kw 170 to 370 kw Features

More information

Liebert CSU3000 DISCONTINUED PRODUCT. CSI Mainframe Cooling Systems. CT(Three Module) Model 20, 30 & 37 ton Mainframe Chiller

Liebert CSU3000 DISCONTINUED PRODUCT. CSI Mainframe Cooling Systems. CT(Three Module) Model 20, 30 & 37 ton Mainframe Chiller DISCONTINUED PRODUCT CSI 15621 - Mainframe Cooling Systems 1.1 SUMMARY Liebert CSU3000 CT(Three Module) Model 20, 30 & 37 ton Mainframe Chiller GUIDE SPECIFICATIONS 1.0 GENERAL These specifications describe

More information

QUOTATION BLADE 7 LX. Product code GEAL6S2BAA

QUOTATION BLADE 7 LX. Product code GEAL6S2BAA 1 of 10 Mattei rotary vane compressors are the result of 90 years of investments in research and development to improve performance and lessen the impact on the environment. Designed for industrial continuous

More information

Product Data. Features/Benefits. 30GTN,GTR Air-Cooled Reciprocating Liquid Chillers with ComfortLink controls 50/60 Hz

Product Data. Features/Benefits. 30GTN,GTR Air-Cooled Reciprocating Liquid Chillers with ComfortLink controls 50/60 Hz Product Data Air-Cooled Reciprocating Liquid Chillers with ComfortLink controls 50/60 Hz Nominal Capacities: 36 to 410 Tons 127 to 1445 Features/Benefits ComfortLink control Your link to a world of simple

More information

ENR Incorporating

ENR Incorporating ENR 002-480 Incorporating R410A Refrigerant Air cooled water chillers with scroll compressors and axial fans, 2.2-480kW ENR 002-100 models inc. self-cleaning coaxial evaporators ENR 130-480 models inc.

More information

kW. Ultima Screw Chiller Range kW. > Ultima Screw Chiller Range. Includes Ultima FreeCool Chiller Range

kW. Ultima Screw Chiller Range kW. > Ultima Screw Chiller Range.   Includes Ultima FreeCool Chiller Range 200-750kW 00-750kW > Ultima Screw Chiller Range Includes Ultima FreeCool Chiller Range Typical Applications > Close Control Cooling > Comfort Cooling > Process Cooling www.airedale.com Designed for a better

More information

CHP

CHP Packaged Unit Heat Pump CHP16-024-030-036-048-060 2-5 Ton Cooling 23,000-57,500 Btuh Heating 12,800-85,300 Btuh (5-25 kw) Optional Electric Heating FEATURES Designed for outdoor rooftop or ground level

More information

ACS Screw Water Chiller R-134a

ACS Screw Water Chiller R-134a ACS Screw Water Chiller R-134a 45-430 TR 158-1512 kw COMMERCIAL AND INDUSTRIAL AIR COOLED SCREW CHILLER 50 Hz For more technical information please visit Table of Contents INTRODUCTION NOMENCLATURE OUT

More information

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C PH120 R410a Refrigerant Rooftop Packaged INDOOR COIL ENTERING AIR TEMP 0 c DB WB 21 23 25 27 29 31 PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C 30 35 40 45 Cap Cap Cap Cap 17 115.3 70.7 11.5

More information

next dx next dx rcgroupairconditioning NEXT DX: Direct expansion close control air conditioners equipped with scroll compressors and Plug-fans.

next dx next dx rcgroupairconditioning NEXT DX: Direct expansion close control air conditioners equipped with scroll compressors and Plug-fans. NEXT DX: Direct expansion close control air conditioners equipped with scroll compressors and Plug-fans. Cooling Capacity: 6,4 97,4 next dx C rcgroupairconditioning R410 E C UP FLOW DOWN FLOW MIN FETURES

More information

JT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency Heat Pump 14 SEER Residential System 1.

JT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency Heat Pump 14 SEER Residential System 1. TECHNICAL SPECIFICATIONS JT4BE Series High Efficiency Heat Pump 14 SEER Residential System 1.5 5 Ton Capacity The JT4BE Series of heat pumps offers exceptional performance. The unit, when combined with

More information

AZURA. Air/water multifunctional chiller&heat pump, kw

AZURA. Air/water multifunctional chiller&heat pump, kw AZURA STM Air/water multifunctional chiller&heat pump, 31-211 kw General Air/water unit with indipendent production of chilled water and hot water equipped with axial fans and hermetic scroll compressors.

More information

Standard features. Optional features

Standard features. Optional features FABRIQUÉ AU CANADA MADEIN CANADA Standard features 3/8 inch inner grooved copper tubing up to 5 fan long units. Reduced refrigerant charge with high heat-transfer. Tube sheets with oversized holes and

More information

JT4BD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 13 SEER Residential System Ton Capacity WARRANTY

JT4BD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 13 SEER Residential System Ton Capacity WARRANTY TECHNICAL SPECIFICATIONS JT4BD Series R-410A High Efficiency Heat Pump 13 SEER Residential System 1.5 5 Ton Capacity The JT4BD Series now offers the choice of a heat pump that uses a more efficient and

More information

SINGLE PACKAGE HEAT PUMPS

SINGLE PACKAGE HEAT PUMPS SINGLE PACKAGE HEAT PUMPS HPP024 THRU 060 2 THRU 5 NOMINAL TONS 13 SEER FACTORY MOUNTED TXV DESCRIPTION These packaged heat pumps are designed for outdoor installation. Only utility and duct connections

More information

S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant

S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant TECHNICAL SPECIFICATIONS S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant The S3BN Series of air conditioners offers exceptional performance from

More information

ROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh

ROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh ROOF TOP (SERIES ) 10.8 TO 103 KW 37,000 TO 351,000 Btuh These rooftop units are complete, self contained air conditioners fully assembled, wire, charged and tested prior to shipment, each unit is delivered

More information

HS17. HS17 SERIES CONDENSING UNITS 17.6 to 65.2 kw ( to Btuh) Cooling Capacity. MATCHED REMOTE SYSTEMS 50hz ENGINEERING DATA

HS17. HS17 SERIES CONDENSING UNITS 17.6 to 65.2 kw ( to Btuh) Cooling Capacity. MATCHED REMOTE SYSTEMS 50hz ENGINEERING DATA ENGINEERING DATA ENGINEERING DATA MATCHED REMOTE SYSTEMS 50hz HS17 SERIES CONDENSING UNITS 17.6 to 65.2 kw (60 200 to 222 500 Btuh) HS17 Bulletin #490001 November 1995 Supersedes August 1994 HS17-1353

More information

Sample Specifications 2110_KA.DOC KOBELCO KNW SERIES 1 OF 10 AIR-COOLED, OIL FREE AIR COMPRESSOR Frame 0, 1, HP

Sample Specifications 2110_KA.DOC KOBELCO KNW SERIES 1 OF 10 AIR-COOLED, OIL FREE AIR COMPRESSOR Frame 0, 1, HP KOBELCO KNW SERIES 1 OF 10 1. SPECIFICATIONS SCOPE 1.1 This specification covers the requirement for supply of a packaged oil-free rotary screw air compressor, Kobelco KNW Series model. 1.2 Any and all

More information

Optional Pump Packages for

Optional Pump Packages for Installation, Operating and Maintenance Manual IOMM AGSD Pump Pkg Group: Chiller Part Number: 331376801 Part Number: 331376901 Date: June 2010 Supersedes: October 2008 Optional Pump Packages for AGS 140D

More information

Total and partial heat recovery RANGE. AQUACIAT power LD series. AQUACIAT power LDC - LDH series. AQUACIAT power ILD series

Total and partial heat recovery RANGE. AQUACIAT power LD series. AQUACIAT power LDC - LDH series. AQUACIAT power ILD series High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Self-adjusting electronic control Cooling capacity: 330 to 500 kw Heating capacity: 340 to 500 kw Cooling

More information

CXAM. Options. Accessories

CXAM. Options. Accessories CXAM Reversible air-to-water scroll heat pump Customer benefits Life cycle effectiveness Efficiency and sound level without compromise All year round operation Extreme reliability and durability Wide application

More information

AHN 064 to 304 EHN/CHN 064 to 304

AHN 064 to 304 EHN/CHN 064 to 304 u Horizontal Packaged and Split Air Conditioners AHN 64 to 34 EHN/CHN 64 to 34 6. to 29.2 kw 6.4 to 29.4 kw Engineering Data Manual EDM AECHN-A.1GB Date : June 28 Supersedes : None Technical Description

More information

YCUJ Millennium TM AIR COOLED CONDENSING UNIT

YCUJ Millennium TM AIR COOLED CONDENSING UNIT YCUJ Millennium TM AIR COOLED CONDENSING UNIT REFRIGERANT R407C COOLING CAPACITIES 348 kw to 760 kw The YCUJ range of Condensing Units are designed for direct expansion cooling and are usually used in

More information

Product Data. Features/Benefits 50JS SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS)

Product Data. Features/Benefits 50JS SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS) SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS) Product Data UNIT (50 Hz) Single-packaged Heat Pump for Residential and Light Commercial applications. Features/Benefits One-piece

More information

LSE kw. Outdoor packaged unit. Air/water chillers and heat pumps LSE PLUS

LSE kw. Outdoor packaged unit. Air/water chillers and heat pumps LSE PLUS Air/water chillers and heat pumps LSE Outdoor packaged unit LSE 60-00 kw Multi-scroll solutions for reliability and high efficiency at partial loads Scroll compressor PLUS R-0A R-0A refrigerant Cooling

More information

Copeland Screw Compressors Semi-Hermetic Compact Operating Instructions

Copeland Screw Compressors Semi-Hermetic Compact Operating Instructions Copeland Screw Compressors Semi-Hermetic Compact Operating Instructions SCH2 & SCA2 High Temperature Compressors 35-240 Horsepower 1. Introduction This series of semi-hermetic compact screw compressors

More information

Conditioning your ambient, maximising your comfort.

Conditioning your ambient, maximising your comfort. High efficiency water cooled chillers, heat pumps and evaporating units with screw compressors and R134a refrigerant gas. Cooling capacity 380 1549 kw Heating capacity 427 1740 kw Cooling capacity condenserless

More information

VT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 14 SEER Residential System Ton Capacity WARRANTY

VT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 14 SEER Residential System Ton Capacity WARRANTY TECHNICAL SPECIFICATIONS VT4BE Series R-410A High Efficiency Heat Pump 14 SEER Residential System 1.5 5 Ton Capacity The VT4BE Series now offers the choice of a heat pump that uses a more efficient and

More information

AFGP12B. Features. Efficiency: 12 SEER 80% AFUE. Warranty: 10-year limited compressor 10-year limited heat exchanger 5-year limited components

AFGP12B. Features. Efficiency: 12 SEER 80% AFUE. Warranty: 10-year limited compressor 10-year limited heat exchanger 5-year limited components AFGP12B Gas/Electric Package Unit Features Shipped for horizontal applications; easily converted to downshot Side-by-side horizontal discharge Standard thermostatic expansion valve Crimp-Tite weld-free

More information

Driving and Connecting Globally. Fan Coil Unit. Model : PHW-K Size : 510CMH~2720CMH. Made in Taiwan

Driving and Connecting Globally. Fan Coil Unit. Model : PHW-K Size : 510CMH~2720CMH. Made in Taiwan Driving and Connecting Globally Fan Coil Unit : PHW-K Size : 510CMH~2720CMH Made in Taiwan Features Superior low-height design. Stainless steel drain pan for condensate and corrosion protection. Flexibe-reverse

More information

Air-Cooled, Scroll Compressor Units

Air-Cooled, Scroll Compressor Units Catalog CAT ACZ-AGZB1-1 Air-Cooled, Scroll Compressor s ACZ 010BS ACZ 039BS, Condensing s AGZ 010BS AGZ 034BS Chillers AGZ 010BM AGZ 034BM Chillers with Remote Evaporators 10 to 40 Tons, (35 to 140 kw)

More information

Product Data. Features/Benefits. 30GXN,R ECOLOGIC Air-Cooled Chiller with ComfortLink Controls 50/60 Hz. 80 to 450 Tons (267 to 1511 kw)

Product Data. Features/Benefits. 30GXN,R ECOLOGIC Air-Cooled Chiller with ComfortLink Controls 50/60 Hz. 80 to 450 Tons (267 to 1511 kw) Product Data 30GXN,R080-450 ECOLOGIC Air-Cooled Chiller with ComfortLink Controls 50/60 Hz 80 to 450 Tons (267 to 1511 kw) ECOLOGIC 30GXN,R air-cooled chillers are designed from the ground up to meet the

More information

... RTU Technical Manual. Packaged Air Conditioning Unit...

... RTU Technical Manual. Packaged Air Conditioning Unit... ... RTU Technical Manual Packaged Air Conditioning Unit... Index. CODING AND MODELS. WORKING LIMITS. TECHNICAL SPECIFICATIONS. PERFORMANCE TABLES. TECHNICAL SPECIFICATIONS FOR OPTIONAL EQUIPMENT. ELECTRONIC

More information

Product Data PH15NB. 15SEERSplitSystemHeatPump with R---410A Refrigerant 1.5 To 5 Nominal Tons AVAILABLE SIZES:

Product Data PH15NB. 15SEERSplitSystemHeatPump with R---410A Refrigerant 1.5 To 5 Nominal Tons AVAILABLE SIZES: 15SEERSplitHeatPump with R---410A Refrigerant 1.5 To 5 Nominal Tons Product Data AVAILABLE SIZES: Nominal sizes are available from 018 through 060 to meet the needs of residential and light commercial

More information

RECOMMENDATIONS FOR USING FREQUENCY INVERTERS WITH POSITIVE DISPLACEMENT REFRIGERANT COMPRESSORS

RECOMMENDATIONS FOR USING FREQUENCY INVERTERS WITH POSITIVE DISPLACEMENT REFRIGERANT COMPRESSORS RECOMMENDATIONS FOR USING FREQUENCY INVERTERS WITH POSITIVE DISPLACEMENT REFRIGERANT COMPRESSORS Contents Page 1 Scope and purpose... 1 2 General... 1 3 Operation... 2 4 Application ranges... 5 5 Design

More information

R-134a. APCY Series Screw Chillers. SKM Compact Screw Chillers APCY Series - R-134a. Range 50 TR to 455 TR (176 kw to 1600 kw)

R-134a. APCY Series Screw Chillers. SKM Compact Screw Chillers APCY Series - R-134a. Range 50 TR to 455 TR (176 kw to 1600 kw) SKM Compact Screw Chillers APCY Series - R-34a R-34a APCY Series Screw Chillers Range 50 TR to 455 TR (76 kw to 600 kw) facebook.com/skmaircon www.skmaircon.com @skmaircon Sharjah Economic Excellence Award

More information