FR Series Heat Exchanger Unit Heater
|
|
- Lee Lewis
- 5 years ago
- Views:
Transcription
1 FR Series Heat Exchanger Unit Heater FR Unit Heaters are extra heavy duty (including heavy gauge steel construction) to meet the most demanding service and long life requirements for rugged industrial applications. The FR Series heaters are specifically designed for steam applications that may be subject to freezing conditions, and are of particular value for outdoor applications. Explosion-proof models suitable for hazardous locations are available on custom order. Engineered for ease of maintenance, all parts are easily removed. All fasteners are plated capscrews; no sheet metal screws are used. Heat exchanger cores are of steel construction with tension wound, close fitting aluminium fins. They are resistant to corrosive agents (including hydrogen sulfide). All units are equipped with a narrow-gap, epoxy coated fan guard. Choose from several optional UL listed and/or CSA approved motors with various voltages, phases and frequencies. All FR models have Canadian CRN approvals and are CSA certified for hazardous locations: Class I, Division 1 & 2, Groups C & D; Class II, Division 1 & 2, Groups E, F, & G; Class III, Division 1 & 2; Temperature Code T3B 329 F (165 C) on applicable models only. Epoxy coated 14-gauge steel cabinet construction connections allow for easy core removal. Optional: 2" (50 mm) 300# Flanges* or 2" NPT Male Connections* Choose from several types of motor, general purpose or explosion proof. UL listed and/or CSA approved. 50 or 60 Hz motors. Tension wound close fitting aluminium finned tubes Heresite is a registered trademark of Heresite Protective Coatings Inc. *2" 300# Flanges and 2" NPT Male Connections increase difficulty in core removal. Figure 29 Full-enclosure fan guard featuring narrow spacing FR Series Unit Heater 63
2 Model Coding FR A1 - A1-1A - D Model Series 12 12" 16 16" 20 20" Model & Size Fan Size 24 24" 30 30" 36 36" A Epoxy powder coated carbon steel B Heresite phenolic coated carbon steel Fan Size 1 Pass FR1 FR1 12 THRU FR1 36 C Stainless steel Exchanger Coatings 1 Heat resistant aluminum paint 2 Heresite phenolic coating Heater Certifi cation 1 purpose 2 Explosion proof, Groups C, D, E, F, & G Connections A 3 CSA certifed heater 1 5/8" (16 mm) diameter x 0.065" (1.7 mm) steel tubes Tension wound aluminum fi ns at 10 fi ns/inch Rows: 3 B 2" NPT Male, SCH. 80 C 2" 300# RF Flange Built-in Disconnect Switch Motor Electrical Specifi cations V Phase Hz A B C D E F G H I J K Unit Heater FR Series NOTEe utilizes Doerr/Emerson/Baldor as our standard motor. Specifying any other O.E.M. motor may result in longer lead times. All heat exchangers are registered to C.R.N. OH C. They are approved for use in all provinces and territories in Canada. Heresite coated exchangers and cabinets: contact factory for quote. Louvres and fan blades are also Heresite coated. Contact factory for shipping lead time. Motor designed to be used at rated voltage with tolerances of ±15%. Motor may be marked 230V, but is suitable for 208V operation phase motors are only certifi ed for groups D, F & G. Built in Disconnect only available with CSA certifi ed heaters. Not available on 36 units. 64
3 FR Single Pass The FR Series is designed for steam applications that may be subject to freezing conditions. Maximum operating pressure is to. This heater is of particular value for outdoor applications, such as on drilling rigs, where boiler failure or crew neglect may result in an accidental freeze-up of the heating system. If accidental freeze-up occurs it is highly recommended the heater be returned to Thermon Heating Systems for inspection. Figure 31 Optional Built-in Disconnect Available Figure 30 The fluid flow is divided among all tubes. This is best suited to steam and high flow rate liquid applications. The Disconnect Switch is engineered for use in the most demanding applications such as drilling rigs, utilidors and compression stations where high vibration, dirt, moisture, fluctuating power and high impact conditions exist. The built-in disconnect switch is available on all FR heaters. Table 34 Performance Data for FR1-12 Entering Steam Refer to the Ruffneck TM HP model for service above 100 psi. For 50 Hz power supply, derate output by 10% FR Series Unit Heater 65
4 Table 35 Performance Data for FR Refer to the Ruffneck TM HP model for service above 100 psi. Above figures are based on calculations at sea level and are intended as reference material only. Results may vary due to customer applications. Table 36 Performance Data for FR Unit Heater FR Series Refer to the Ruffneck TM HP model for service above 100 psi. For 50 Hz power supply, derate output by 10%
5 Table 37 Performance Data for FR Refer to the Ruffneck TM HP model for service above 100 psi. Above figures are based on calculations at sea level and are intended as reference material only. Results may vary due to customer applications. Table 38 Performance Data for FR Refer to the HP model for service above 100 psi. For 50 Hz power supply, derate output by 10%. FR Series Unit Heater 67
6 Table 39 Performance Data for FR Refer to the HP model for service above 100 psi. Above figures are based on calculations at sea level and are intended as reference material only. Results may vary due to customer applications Unit Heater FR Series 68
7 Specifications FR CFM 1147 FPM psi stream Propeller Fan 3 Wing Aluminum, 12 (305 mm) Dia. 5/8 (16 mm) Bore Motor Requirements 1/2 HP, 1725 RPM, Frame 56 1/4 (6 mm) probe will not enter. 5/8 (16 mm) NC Tap - 2 holes (2 mm) steel Net Weight 75 lbs (34 kg) * Shipping Weight 102 lbs (46.3 kg) * Figure 32 Add 12 lbs (5.4 kg) to flange units * Add 15 lbs (6.8 kg) to disconnect units FR1-16 Figure 33 * At 70 F (21 C) at sea level Add 12 lbs (5.4 kg) to flange units * Add 15 lbs (6.8 kg) to disconnect units Number of Tubes 13 Number of Rows 2 Max. Operating Temp. 80 psi for CSA Certified Steam Heaters 650 F (343 C) 1588 CFM 1069 FPM psi stream Propeller Fan 3 Wing Aluminum, 16" (406 mm) Dia. 5/8" (16 mm) Bore Motor Requirements 1/2 HP, 1725 RPM, Frame 56 1/4" (6 mm) probe will not enter " (2 mm) steel Net Weight 109 lbs (49.4 kg) * Shipping Weight 137 lbs (62.1 kg) * Number of Tubes 17 Number of Rows 2 FR Series Unit Heater 69
8 Max. Operating Temp. 572 F (300 C) FR CFM 1153 FPM psi stream Propeller Fan 3 Wing Aluminum, 20" (508 mm) Dia. 5/8" (16 mm) Bore Motor Requirements 1/2 HP, 1725 RPM, Frame 56 1/4" (6 mm) probe will not enter " (2 mm) steel Net Weight 138 lbs (62.6 kg) * Shipping Weight 161 lbs (73 kg) * Figure 34 Add 12 lbs (5.4 kg) to flange units * Add 15 lbs (6.8 kg) to disconnect units. FR1-24 Number of Tubes 21 Number of Rows 2 Max. Operating Temp. 650 F (343 C) Unit Heater FR Series * At 70 F (21 C) at sea level Figure 35 Add 12 lbs (5.4 kg) to flange units * Add 15 lbs (6.8 kg) to disconnect units 3405 CFM 981 FPM psi stream Propeller Fan 3 Wing Aluminum, 24" (610 mm) Dia. 5/8" (16 mm) Bore Motor Requirements 1/2 HP, 1725 RPM, Frame 56 7/16" (11 mm) probe will not enter " (2 mm) steel Net Weight 191 lbs (86.6 kg) * Shipping Weight 224 lbs (101.6 kg) * Number of Tubes 38 Number of Rows 3 Max. Operating Temp. 100 psi for CSA Certified Steam Heaters 650 F (343 C) 70
9 FR1-30 Figure 36 Add 12 lbs (5.4 kg) to flange units * Add 15 lbs (6.8 kg) to disconnect units 4569 CFM 814 FPM psi stream Propeller Fan 3 Wing Aluminum, 30" (762 mm) Dia. 5/8" (16 mm) Bore Motor Requirements 3/4 HP, 1140 RPM, Frame 56 7/16" (11 mm) probe will not enter " (2 mm) steel Net Weight 286 lbs (121.6 kg) * Shipping Weight 345 lbs (156.5 kg) * Number of Tubes 47 Number of Rows 3 Max. Operating Temp. 80 psi for CSA Certified Steam Heaters 650 F (343 C) FR1-36 Figure 37 Add 12 lbs (5.4 kg) to flange units * Add 15 lbs (6.8 kg) to disconnect units. Propeller Fan 7830 CFM 852 FPM psi stream 6 Wing Aluminum, 36" (914 mm) Dia. 1" (25mm) Bore Motor Requirements 1½ HP, 1725 RPM, Frame 56 Drive Pulley Driven Pulley Drive Belt Fan Speed B3.6" B9.9" B42 V-Belt 627 RPM Steel, Powder Coated Epoxy, 1/2" (13 mm) gap 0.105" (2.66 mm) steel Net Weight 534 lbs (242.2 kg) * Shipping Weight 597 lbs (270.8 kg) * Number of Tubes 59 Number of Rows 3 Max. Operating Temp. 85 psi for CSA Certified Steam Heaters 650 F (343 C) FR Series Unit Heater 71
FR Heat Exchanger Unit Heater
Unit Heater Ruffneck are extra heavy duty (including heavy gauge steel construction) to meet the most demanding service and long life requirements for rugged industrial applications. The Series heaters
More informationHP Heat Exchanger Unit Heater
Unit Heater Ruffneck are extra heavy duty (including heavy gauge steel construction) to meet the most demanding service and long life requirements for rugged industrial applications, such as space heating
More informationAH / AV. Advanced Series Unit Heaters AH / AV. Ruffneck
The Ruffneck Advanced Series heaters are designed for rugged industrial applications and are available in 37 models from 6,000 to 1,,000 Btu/hr With a maximum operating pressure and temperature rating
More informationSRH2. Steam Rig Heater. Industrial Grade Heat-Exchanger Unit Heaters. CRN: 0H C 150 psig (1034 KPa)
SRH2 EAC Ex models available. Contact factory! Steam Rig Heater CRN: 0H14931.2C 150 psig (1034 KPa) Industrial Grade Heat-Exchanger Unit Heaters www.hazlocheaters.com is a manufacturer of industrial-grade
More informationComfort. Description. Applications
Blower Heater 3-35 kw 10,236-119,420 Btuh 208, 240, 480 and 575 Volt 1 or 3 Phase Built-in Controls Description Type is designed to heat areas classified as hazardous locations to provide primary or supplementary
More informationComfort. Sewage Treatment Plants. Petrochemical Facilities, Oil Rigs. Unattended Pumping Stations. Chemical Storage and Handling Facilities
3-35 kw 10,200-119,420 Btuh 208 to 600 Volts 1 or 3 Phase Meets NEC, OSHA and UL Requirements ATEX and GOST Models Available Refer to WR-80EP in the Controls section. F-4 Description Type is designed to
More informationTubular Centrifugal Inline Fans Page Introduction... 2 Construction Features... 3 Specification and Dimension Data TCN-D (Inline Fan- Direct
Tubular Centrifugal Inline Fans Page Introduction........................................... 2 Construction Features.................................. 3 Specification and Dimension Data TCN-D (Inline Fan-
More informationC13 / C15 / C18 SOUND ATTENUATED ENCLOSURES
/ / SOUND ATTENUATED ENCLOSURES US Sourced Diesel Generator Set - 750 60 Hz Image shown may not reflect actual configuration Features Robust / Highly Corrosion Resistant Construction Factory installed
More informationC13/C15/C18 Sound Attenuated Enclosures. Features. Enclosures. U.S. Sourced Diesel Generator Set kw 60 Hz
// Sound Attenuated Enclosures U.S. Sourced Diesel Generator Set - kw 60 Hz Image shown may not reflect actual configuration Features Robust/Highly Corrosion Resistant Construction Factory installed on
More informationHigh Pressure Solenoid Valves
High Pressure Solenoid Valves Available for Quick Delivery Controls the flow of Gases & Liquids up to 15,000 PSIG Natural Gas, Hydrogen & other High Pressure Gases High Pressure Cryogenics Flammable Liquids
More informationMODEL TDB TUBEAXIAL INLINE BELT DRIVEN DUCT FAN
TUBEAXIAL INLINE BELT RIVEN UCT FAN Model Features Rated up to 75,490 CFM in static pressure applications up to 1-1/2 w.g. 12 sizes ranging from 12 to 60 propeller diameters Motor drives are located outside
More informationMODEL CTB TUBULAR CENTRIFUGAL INLINE BELT DRIVEN FAN
MODEL FEATURES Rated up to 20,000 CFM in static pressure applications up to 2-1/2 w.g. Motor drives are located outside of the airstream Ideal for applications where space is limited Belt drives permit
More informationUtility Sets Standard Design Features Standard design features common to all Class I and Class II fans
Standard Design Features Utility Sets Standard Design Features Standard design features common to all Class I and Class II fans Shaft AISI 1045, turned ground and polished for accuracy. Designed to provide
More informationList Price. Mult. Sym. C Dim. Single Phase
Single and Three Phase, Foot Mounted Explosion Proof 1/4 thru 300 48 thru 449TY Applications: Ideal for use where hazardous fumes or dust may be present. Features: U.L. and CSA approved for Class I, Group
More information1/4 thru 300 Hp NEMA 48 thru 449TY. List Price. Mult. Sym. C Dim. Single Phase
Single and Three Phase, Foot Mounted Explosion Proof 1/4 thru 300 48 thru 449TY Applications: Ideal for use where hazardous fumes or dust may be present. Features: U.L. and CSA approved for Class I, Group
More informationFluid Cooling Mobile AOHM / AOVHM Series
Fluid Cooling Mobile Series 0916 Performance Notes AO/AOVH Series with hydraulic motor Adjustable louvers (manual) High heat removal Heavy duty construction Wide flow range Heat removal up to 210,000 BTU/HR
More informationElectric Actuated Ball Valves 150# Flanged Stainless Steel, Full Port 1/2 to 4 inch Pipe
1/2 to 4 inch Pipe Features Direct mount ISO5211 Full Port stainless steel ball valve 2-piece ANSI Class 150 flanged body 275 PSI working pressure at 100 F (38 C) Highly visual dome style valve position
More informationModel LIDA. DIRECT DRIVE TUBEAXIAL FANS Model LIDA DIRECT DRIVE TUBEAXIAL FANS SECTION 12. Application. Options/Accessories
IRECT RIVE TUBEAXIAL FANS Model LIA Model LIA IRECT RIVE TUBEAXIAL FANS SECTION 12 Application Carnes Company tubeaxial fans offer one of the widest ranges of sizes, horsepower and performance in the industry.
More informationInline and Roof Mounted Fans
CV Inline and Roof Mounted Fans Page Introduction........................................... 2 Construction Features................................. 3-4 Specifications and Dimension Data CVD (Direct Drive
More informationAir-Cooled Fluid Cooler
Catalog KM-FSD-0313A FS/ FD Series Air-Cooled Fluid Cooler Consider The Possibilities Cools most any non-corrosive fl uid Closed-circuit cooling avoids contamination Cold weather economizer for interior
More informationPropeller Fan BE Series
Propeller Fan BE Series ENCLOSED BELT DRIVEN WALL EXHAUST THESE LOW PRESSURE BELT DRIVEN S ARE IDEALLY SUITED FOR VENTILATION OF UNDERGROUND GARAGES OF APARTMENT BUILDINGS, WAREHOUSES, PUBLIC BUILDINGS,
More informationElectric Actuated 3-Way Ball Valves T-Port Diverter, Stainless Steel, Full Port 1/4 to 2 NPT
T-Port Diverter, Stainless Steel, Full Port 1/4 to 2 NPT Features Full Port direct mount 316 SS ball valve Functions as a diverter valve 1000 PSI working pressure at 100 F (38 C) Visual valve position
More informationTwin City Fan & Blower
BULLETIN 600 Twin City Fan & Blower September 2009 VENTILATING SETS TYPE BCV (Backward Inclined) TYPE BCVU5 (UL 705 Listed) TYPE BCVU2 (UL 762 Listed) TYPE BCVSH (UL Smoke & Heat) TYPE BAV (Airfoil) TYPE
More informationSquare Inline Fans with Multi-Directional Discharge
SQN Square Inline Fans with Multi-Directional Discharge Page Introduction............................................2 Standard Construction Features............................ 3 Specifications and Dimension
More informationA Division of Nailor International Inc. ECONOMY AIR HANDLERS
A Division of Nailor International Inc. MODEL : ECONOMY AIR HANDLERS Thermal Model Standard Specification MODEL 800-4000 CFM AIR HANDLERS Description Model air handlers are designed for efficient and economical
More informationSUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ)
550.39-TG1YI (994) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS H5CE090 & H3CE120 7.5 AND 10 NOMINAL TONS (World 50HZ) HCE090 SUNLINE 2000 DESCRIPTION These Sunline 2000 units are completely assembled, piped
More informationCompact Electric Actuated 3-Way Ball Valves T-Port, 316 Stainless Steel, Full Port 1/4 to 3/4 NPT
Compact Electric Actuated 3-Way Ball Valves T-Port, 316 Stainless Steel, Full Port 1/4 to 3/4 NPT Features Industrial quality miniature actuator Full Port direct mount 3-way stainless steel ball valve
More informationK SERIES DIRECT DRIVE SIDEWALL PROPELLER FANS
K Series Direct Drive K SERIES DIRECT DRIVE SIDEWALL PROPELLER FANS SPECIFICATIONS Fans shall be direct drive propeller type with integral motorside OSHA style guard. Propeller construction shall be of
More informationMODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER
MODEL MODEL FEATURES Exhaust air up to 60,116 CFM in static pressure applications up to 1 w.g. Straight-through air flow design results in maximum exhaust efficiency Motor and drives are located outside
More informationUnit Heaters. Catalog MANUFACTURERS HEATING PRODUCTS. Tel: (905) Fax: (905) OF HYDRONIC.
Catalog MANUFACTURERS OF HYDRONIC HEATING PRODUCTS Tel: (905) 670-3200 Fax: (905) 670-3822 General Product Overview Sigma horizontal and vertical propeller unit heaters feature a wide performance range
More informationAir Moving Solutions. VENTILATING SETs BCV BCVU5 BCVU2 BCVSH BAV FCV
Air Moving Solutions. VENTILATING SETs BCV BCVU5 BCVU2 BCVSH BAV FCV CATALOG 600 March 2012 VentilatingSets Models BCV BCVU5 BCVU2 BCVSH BAV FCV Twin City Fan s line of utility ventilating sets is one
More informationZEPHYR CABINET. Single & Twin Unit Cabinet Fans. Moving Your Way BULLETIN ZC15 TABLE OF CONTENTS
ZEPHYR CABINET Single & Twin Unit Cabinet Fans Moving Your Way TABLE OF CONTENTS Introduction, Certifications & Listings, Features & Benefits 3 Options & Accessories 4 Typical Applications & Belt Drive
More informationCHP
Packaged Unit Heat Pump CHP16-024-030-036-048-060 2-5 Ton Cooling 23,000-57,500 Btuh Heating 12,800-85,300 Btuh (5-25 kw) Optional Electric Heating FEATURES Designed for outdoor rooftop or ground level
More information2520- EC Motor Speed Controller
2520- EC Motor Speed Controller T1 AC Line Voltage From Contactor T2 or Neutral 760-ECM ECM Motor BLACK ORANGE BLACK RED (+) Signal 24VAC (-) GND Features Motor Types: ECM (dc brushless) Motors Motor Speed:
More informationMid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter
BULLETIN NO. 220/11 (SUPERSEDES BULLETIN NO. 220/06) Mid-West Instrument Piston Type Model 220 Hazardous Locations Indicating / Non-Indicating Differential Pressure Switch or Transmitter Low cost piston
More informationEngineering Information. Solenoid Valves Principles of Operation. Solenoid Valves. Direct Acting Valves (Figures 1A, 1B)
4 Engineering Information Principles of Operation A solenoid valve is a combination of two basic functional units: A solenoid (electromagnet) with its core A valve body containing one or more orifices
More informationMODELS HRSB & HRSD HOODED PROPELLER ROOF SUPPLY FANS
MODEL FEATURES Supply air to over 56,000 CFM up to 3/4 w.g. Belt drives permit easy performance adjustments when needed Direct drive units have low sound levels and quiet operation. Filtered models available
More informationFixed Pitch Vane Axial Fan
Fixed Pitch Vane Axial Fan Page Introduction...........................................2 Construction Features...................................3 Mounting Options.......................................3
More informationAxial Propeller Panel Fans, PAF-Series
Axial Propeller Panel Fans, PAF-Series TABLE OF CONTENTS 3 Introduction 4 Certifications & Listings 4 Options & Accessories 9 Motor Availability 11 Direct Drive Dimensional & Performance Data 14 Belt Drive
More informationExplosionproof enclosures XPCJ series Cast aluminum steel control/junction box
1 TECHNICAL DATA SHEET Explosionproof enclosures XPCJ series Cast aluminum steel control/junction box XPCJ series series of explosionproof aluminum enclosures are typically used in the packaging of electrical/electronic
More informationPropeller Fan BE Series
Propeller Fan BE Series ENCLOSED BELT DRIVEN WALL EXHAUST FAN THESE LOW PRESSURE BELT DRIVEN FANS ARE IDEALLY SUITED FOR VENTILATION OF UNDERGROUND GARAGES OF APARTMENT BUILDINGS, WAREHOUSES, PUBLIC BUILDINGS,
More information10AC DIPLOMAT SERIES RFC SYSTEMS
10AC DIPLOMAT SERIES CONDENSING UNITS RFC SYSTEMS 10.05 to 10.55 SEER *11,100 to 60,000 Btuh (3.3 to 17.6 ) 1 thru 5 Tons (3.5 to 17.6 ) *ARI and DOE Certified Ratings CONDENSING ENGINEERING UNITS DATA
More informationDESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS
DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS These completely assembled units include a well-insulated cabinet, a DX cooling coil
More informationApplications. Illustrated Features
Applications For use in locations where a high degree of corrosion resistance is required. FR Series: For use in areas where high humidity or water vapor are present Typical uses include meat- or food-processing
More informationCentrifugal Utility Fans - SFD/SFB
C H F D B G E A Centrifugal Utility Fans - SFD/SFB SFB STANDARD CONSTRUCTION FEATURES HOUSING: Heavy gauge steel housing with Lock-seam construction Unit support angles with prepunched mounting holes Adjustable
More informationDESCRIPTION FEATURES
SPLIT-SYSTEM AIR COOLED CONDENSING UNIT H5CE150, H5CE180 AND H5CE240 12-1/2, 15 AND 20 NOMINAL TONS (World 50Hz) DESCRIPTION These outdoor condensing units are completely assembled, piped and wired at
More informationMODELS CSF & LSF BELT DRIVE CENTRIFUGAL FILTERED SUPPLY FANS
S CSF & LSF Model CSF Hooded Design FEATURES Supply air to over 13,000 CFM in static pressure capabilities to 2 w.g. Heavy-galvanized construction Belt drives permit easy performance adjustments when needed
More informationNH 3. Evaporator. Ammonia Applications Tons MANP
NH 3 Evaporator Ammonia Applications 12-108 Tons > > Used for medium TO large Industrial Ammonia applications Manufactured with Stainless steel tubes. The Global Leader In Heat Exchange Technology With
More informationTube Axial Fan Page Specifications & Dimension Data Performance Data
Tube Axial Fan Page Introduction........................................... 2 Construction Features................................... 3 Information........................................... 4 Specifications
More informationMODELS HREB-C & HRED-C HOODED PROPELLER ROOF EXHAUST FANS
MODEL FEATURES Exhaust air to over 40,000 CFM up to 3/4 w.g. Belt drives permit easy performance adjustments when needed Direct drive units have low sound levels and quiet operation. Reversible blades
More informationSQBI BLOWERS BACKWARD INCLINED CLASS II CLASS IIP CLASS III. OEM and Industrial Air Handling Specialist
OEM and Industrial Air Handling Specialist SQBI BLOWERS BACKWARD INCLINED CLASS II CLASS IIP CLASS III 7697 Snider Road, Mason, OH 4040-913 Telephone: 13-73-0600 Visit us at www.cincinnatifan.com for more
More informationSUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS
550.23-TG1Y (595) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS H4CE090 & H2CE120 & H1CE150 7-1/2, 10, & 12-1/2 NOMINAL TONS 8.9-9.5 EER SUNLINE 2000 HCE090 208/230/460 VOLT ONLY 208/230/575 VOLT ONLY DESCRIPTION
More informationPowertite Series Pin and Sleeve Plugs, Connectors and Receptacles
Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles Applications Designed to supply power to portable or fixed electrical equipment such as motor generator units, welders, pumps, compressors,
More informationIntegrated Control modules
.604.0 - Rev: 6, Page of Integrated Control modules QC4, QC42 and QC43 Features: - Basic actuator functions for: - Spring return applications, or - Double acting applications or, - Double acting Fail in
More informationElectric Actuated Ball Valves 3-piece Stainless Steel, Full Port 1/4 to 3 NPT
1/4 to 3 NPT Features Direct mount ISO5211 Full Port stainless steel ball valve 3-piece swing out body designed for easy maintenance 1000 PSI working pressure at 100 F (38 C) Highly visual dome style valve
More informationJ 6 Se r i e s. Pressure and Vacuum switches. features
J 6 S er i es J 6 Se r i e s Pressure and Vacuum switches features Gasketed, Die Cast Aluminum Enclosure with Epoxy Coating SPDT Switch Output Adjustable Deadband Option Sealed, Isolated Metal Bellows
More informationM-SERIES MHP4 MODEL NUMBER GUIDE 3 M HP F P 1 ELECTRIC HEAT PUMP PACKAGED UNITS REVISION CODE
ELECTRIC HEAT PUMP PACKAGED UNITS MHP4 FORM NO. MHP4-100 (10/2018) MODEL NUMBER GUIDE 3 M HP 4 11 18 1 F P 1 FACTORY INSTALLED ELECTRIC HEAT 3= 3 KW 5 = 5 KW 7 = 7 KW 10 = 10 KW M = MAGIC-PAK HP = HEAT
More informationLinear Valve Electric Actuator
Linear Valve Electric Actuator www.powervalves.nl Company Profile Company Profile Sun Yeh Electrical Ind. Co., Ltd. was founded in 1986. We always strive for technical excellence, innovation and the highest
More informationSealed Enclosure Cooling
ADVANCED COOLING TECHNOLOGIES The Thermal Management Experts Sealed Enclosure Cooling C U L US LISTED SA4469 ACT Heat Sink Cooler Series ACT Heat Pipe Cooler Series Sealed Enclosure Coolers Keep The Inside
More informationEnclosures for hazardous areas EBMX clamped enclosures. Clamped EBMX. NEMA 7 classifi ed enclosures
Enclosures for hazardous areas clamped enclosures Clamped NEMA 7 classifi ed enclosures Clamped : NEMA 7 classified enclosures Safer. Faster. Easy access, lower risk and less downtime. Creative thinking
More informationTXB Series Explosion Proof
General Characteristics of TXB Series The TXB Series is recommended for most paint spray applications because the motor is out of the air stream and not exposed to paint overspray. For Industrial and commercial
More informationElectric Actuated Butterfly Valves Ductile Iron Lug Body ASME 150# 2 to 6 Pipe
2 to 6 Pipe Features Direct mount lug butterfly valve with ISO5211 mount 3-layer epoxy coated ductile iron body with 316 SS disc Unique wave line seat reduces torque and extends seal life Visual valve
More informationJefferson Electric Class I Division 2 Transformers for hazardous locations
Class I Division 2 Jefferson Electric Class I Division 2 Transformers for hazardous locations Jefferson Electric offers a full line of Class I Division 2 transformers. Jefferson Electrics Class I Division
More informationConsider The Possibilities...
FS/FD Air-Cooled Fluid Cooler Catalog 710.1 Consider The Possibilities... Cools most any non-corrosive fluid Closed-circuit cooling avoids contamination Cold weather economizer for interior cooling loads
More informationDirect Fire Heated Make-Up Air Unit
Direct Fire Heated Make-Up Air Unit Cover1 Culture of Quality Loren Cook Company is proud to be a leader in the design and manufacturing of fans, blowers, gravity ventilators, lab exhaust systems and energy
More informationUTILITY BLOWERS. Models: BIUB / BIUBR / BIUBSH BAUB / DFC / FCUB. The Industrial Choice.
UTILITY BLOWERS Models: BIUB / BIUBR / BIUBSH BAUB / DFC / FCUB The Industrial Choice. CATALOG 760 April 2017 Utility Blowers Overview Utility Blowers Aerovent s line of utility blowers is one of the most
More information29 Series OEM Style Bronze Safety Valves for Steam, Air and Non-Hazardous Gas
Section I Power Boilers OEM Style for Steam, Air and Non-Hazardous Gas Section VIII Pressure Vessels Conbraco is ideally suited for OEM applications where compact size, dependable performance and maximum
More informationMODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER
MODEL TUB MODEL FEATURES Exhaust air up to 60,116 CFM in static pressure applications up to 1 w.g. Straight-through air flow design results in maximum exhaust efficiency Motor and drives are located outside
More informationSPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES EER 8.5 ARI RATINGS* K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS
550.13-TG11Y (0500) SPLIT-SYSTEM EVAPORATOR BLOWER K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS EER 8.5 DESCRIPTION This completely assembled dual circuit evaporator blower includes a well-insulated
More informationMAX-E1 HIGH EFFICIENCY. Severe Duty
MAX-E1 HIGH EFFICIENCY Severe Duty DESIGN FEATURES & CONSTRUCTION ALL MAX-E1 MOTORS DELIVER THESE IMPRESSIVE DESIGN FEATURES HPE - High Pulse Endurance Wire Non-hygroscopic, Class F insulation system High-grade,
More informationTURNING AIR INTO SOLUTIONS. UTILITY SETS DCV BCV BCVR BCVSH BAV DDF FCV
TURNING AIR INTO SOLUTIONS. UTILITY SETS DCV BCV BCVR BCVSH BAV DDF FCV CATALOG 600 March 2017 UTILITY SETS Model DCV Overview Utility Sets Twin City Fan s line of utility ventilating sets is one of the
More informationIndustrial Fans & Blowers
Industrial Fans & Blowers AID AXIAL IN-LINE FANS FEAURES & BENEFIS Spark resistant, cast aluminum airfoil axial impeller Factory set adjustable pitch blades Superior performance and sound characteristics
More information2005 PennBarry All rights reserved.
Fan Introduction CERTIFIED RATINGS PennBarry certifi es that the direct drive and belt drive models shown on pages 12-1, and 18-9 are licensed to bear the AMCA seal. The ratings shown are based on tests
More informationDual Discharge Evaporator (DX) Freon Applications 1-19 Tons MDN
Dual Discharge Evaporator (DX) Freon Applications 1-19 Tons MDN > > Used for small to medium Freon applications The Global Leader In Heat Exchange Technology With seven decades of experience and commitment
More informationClass I, Div. II Fluorescent Fixture - Emergency Battery Backup - Corrosion Resistant (Saltwater) -
Class I, Div. II Fluorescent Fixture - Emergency Battery Backup - Corrosion Resistant (Saltwater) - Part #: HALP-EMG-24-2L-BX Made in the USA The Larson Electronics HALP-EMG-24-2L-BX Hazardous Area Fluorescent
More informationMid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter
BULLETIN NO. 240/11 (SUPERSEDES BULLETIN NO. 240/06) Mid-West Instrument Diaphragm Type Model 240 Hazardous Locations Indicating / Non-Indicating Differential Pressure Switch or Transmitter Field wireable
More informationB BASIC HEAT TREATMENT CONSOLE
Maritime Stress PO Box 2898, 30 Estates Road Dartmouth, NS, B2W 4Y2, Canada Toll Free: 1-877-468-1781 Phone: (902) 468-7873 Fax: (902) 468-2304 Website: E-mail: info@maritimestress.com OPERATION MANUAL
More informationCode Master Incandescent Factory Sealed Luminaires Explosionproof, Dust-Ignitionproof For use with threaded metal conduit.
Applications For use in hazardous locations such as plants where plastics, paints, thinners and petrochemicals are manufactured. For use in chemical and petrochemical plants, such as manufacturers of plastics,
More informationFILTERED AIR SUPPLY FANS. Direct Drive & Belt Driven Models FSR / FSWD / FSWB / FF. Model FSWB Wall Mounted. Model FSR Roof Mounted
The Industrial Choice. Model FSWB Wall Mounted Model FSR Roof Mounted FILTERED AIR SUPPLY FANS Direct Drive & Belt Driven Models FSR / FSWD / FSWB / FF CATALOG 664 June 2013 Filtered Air Supply Fans Roof
More informationGLOBAL STANDARD COOLER
GLOBAL STANDD COOLER AKG 009 (changes and errors expected) Sales@SouthwestThermal.com p. 888-6-8 f. 80-484-0049 www.akgcoolers.com GLOBAL STANDD Rugged Environment COOLING SYSTEMS Product Information AKG
More informationMODELS GED/GSD, eged/egsd, DFE/DFS, DDE/DDS
LINE OVERVIEW Jenco s Direct Drive Sidewall Propeller line is designed to exhaust or supply large volumes of air at relatively low static pressures. With 3 types of construction, the direct drive models
More informationTwin City Fan & Blower
Twin City Fan & Blower VENTILATING SETS TYPE BCV (Backward Inclined) TYPE BCVU5 (UL 705 Listed) TYPE BCVU2 (UL 762 Listed) TYPE BCVSH (UL Smoke & Heat) TYPE BAV (Airfoil) TYPE FCV (Forward Curved) Ventilating
More informationSeries 810: 2 Way Angle Body Valves: 1/4 to 3 NPT
Series 810: 2 Way Angle Body Valves: 1/4 to 3 NPT FEATURES Compact design, high fl ow rates Visual position indicator standard For temperatures from 22 F to +430 F / -30 C to 221 C Working pressures up
More informationSurface Mount Explosion Proof, Waterproof Fluorescent Lights - T12 Very High Output - Oil Rigs - 2 L
Surface Mount Explosion Proof, Waterproof Fluorescent Lights - T12 Very High Output - Oil Rigs - 2 L Part #: EPL-48-2L-T12VHO Made in the USA The Larson Electronics EPL-48-2L-T12VHO Explosion Proof Fluorescent
More informationMODELS LCE/LCS, L2E/L2S, L3E/L3S
LINE OVERVIEW S&P s Belt Drive Sidewall Propeller line is designed to exhaust or supply large volumes of air at relatively low static pressures. With levels of construction, the belt drive models are for
More information10 S e r i e s PRESSURE SWITCH. features
10 S er i es 10 S e r i e s PRESSURE SWITCH features Tamper-Resistant Field Adjustment Adjustable Ranges from 4 to 7500 PSI (0,3 to 517,1 Bar) Choice of 7 Electrical Terminations 1-1/4" Diameter Height
More informationFeatures/Benefits INSTALL IT & FORGET IT FEATURES & BENEFITS
Features/Benefits INSTALL IT & FORGET IT The ForceMeter TM offers the same rugged design for which the Niagara Meters brand is known. The ForceMeter is ideal for applications including water, compressed
More informationStandard features. Optional features
FABRIQUÉ AU CANADA MADEIN CANADA Standard features 3/8 inch inner grooved copper tubing up to 5 fan long units. Reduced refrigerant charge with high heat-transfer. Tube sheets with oversized holes and
More informationSPECIFICATIONS SEWAGE/SUMP DUPLEX SYSTEM ZOELLER COMPANY SUBMERSIBLE SEWAGE OR DEWATERING PUMPS
Your Peace of Mind is Our Top Priority Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: P.O. BOX 16347
More informationPHB SERIES 7-1/2 and 10 TON
PHB SERIES 7-1/2 and 10 TON COMMERCIAL SINGLE PACKAGE HEAT PUMPS COMMERCIAL PACKAGE HEAT PUMP FEATURES Representative photo only, some models may vary in appearance. Rated in accordance with ARI Standard
More informationINDUSTRIES AMERICAN COOLAIR CORPORATION. Centrifugal Filtered Supply Roof Ventilators TYPE CFS - TYPE SIS
INDUSTRIES AMERICAN COOLAIR CORPORATION Centrifugal Filtered Supply Roof Ventilators TYPE CFS - TYPE SIS CFS Centrifugal Filtered Supply Fans Applications The CFS Centrifugal Filtered supply fans with
More informationMODELS LCE/LCS, L2E/L2S, L3E/L3S
ELT DRIVE SIDEWLL PROPELLER FNS LINE OVERVIEW Jenco s elt Drive Sidewall Propeller line is designed to exhaust or supply large volumes of air at relatively low static pressures. With 3 levels of construction,
More informationGenerator and Motor Coolers
Generator and Motor Coolers Enerfin Generator and Motor Coolers (RAM) are manufactured and designed to ASME codes and TEMA standards as required. Our coolers with removable covers can be manufactured using
More informationType VA Vanax Fans. Models VA, VAD, & VAB
Type VA Vanax Fans Models VA, VAD, & VAB Type VA Direct Drive Model VA Sizes 6 through 10 207 to 1,811 CFM Static Pressure to 1-1/2 Type VAB Belt Drive Model VAB Sizes 12 through 48 1,004 to 47,176 CFM
More informationGLOBAL STANDARD COOLER
GLOBAL STANDD COOLER AKG 2009 (changes and errors expected) GLOBAL STANDD Rugged Environment COOLING SYSTEMS Product Information AKG CooL-Line is a standard line of products from the market leader in high
More informationGLOBAL STANDARD COOLER
GLOBAL STANDD COOLER AKG 2009 (changes and errors expected) GLOBAL STANDD RUGGED ENVIRONMENT COOLING SYSTEMS PRODUCT INFORMATION AKG CooL-Line is a standard line of products from the market leader in high
More informationCX1 ProVector Explosion-Proof Heaters
Explosion-Proof Heaters For hazardous locations heating, rely on the for the most dependable, troublefree service available. CCI Thermal Technologies Inc. manufactures explosion-proof air heaters to satisfy
More informationINDUSTRIAL DIRECT DRIVE 14 Positive Indirect Gas Heated Air Curtain Data Sheet
For Mounting Heights To 14 (environmental separation) STANDARD CONSTRUCTION 1 hp single speed motor(s) - direct drive (Optional: two-speed) Gray powder coated exterior with mill aluminum screen and access
More informationElectric Actuated Butterfly Valves Ductile Iron Lug Body ASME 150# 2 to 6 Pipe with EPS Positioner
2 to 6 Pipe with EPS Positioner Features EPS- Electronic Positioning System with 4-20mA/0-10V input Lug body valve with ISO5211 direct mount actuator 3-layer epoxy coated ductile iron body with 316 SS
More informationLiquid Turbine Flowmeters
NUFLO Liquid Turbine Flowmeters Accurate Flow Measurement In 1957, this flowmeter was developed with a tungsten-carbide shaft and bearing to withstand the rugged conditions of the oil field. Over the years,
More information