AKRON. Made in the U.S.A The Akron Products Company - FLOOR-MONO112911

Size: px
Start display at page:

Download "AKRON. Made in the U.S.A The Akron Products Company - FLOOR-MONO112911"

Transcription

1 The Akron Products Company MONO POSTS FLOOR JACKS MOBILE HOME JACKS WINDOW WELLS

2 A Few Important Things That Differentiate Us From Any Other... Vertically integrated tube mills, means that we do not have to rely on outside suppliers and therefore are a more stable source now and long term. Our manufactured, adjustable columns have an ICC-ES report (#1767) and a CCMC Listing (1320-L) providing evidence of compliance with the 2009 IBC, 2009 IRC, and Canadian Standard CAN/CGSB All of our adjustable columns are powder coated which not only gives you the best available protection and finish but is also environmentally friendly and green by design Technically sophisticated for maximum productivity, consistency of quality and supply chain dependability. North American lead referral The Akron Products Company - FLOOR-MONO South Water Street Ext. Meadville, PA 1633 Phone: Fax: us: info@akronproducts.com Made in the U.S.A. 2 pg.

3 PROFESSIONALS CHOICE 11 Ga. Adjustment Range BIG MOE FLOOR JACK O.D. Lower, 2½ O.D. Upper; 16 x 4 x 6 Plates UPC Compression Load Range* Weight Unit Cube BIG MOE 4 ft. 8 in. - 8 ft. 4 in. / 6" ,000 lbs. to 20,000 lbs. 31 lbs. 0. *Compression load is testing to the point of failure. Maximum loads are obtained at minimum extension. To determine safe or allowable loads, consult a licensed engineer. Galvanized Top Swivel Plate with Positive Locating Hole Anchors Screw Adjustment Adjusting Screw - SAE Inside Tube is 11 Gauge Heavy Duty High Carbon Steel, With Adjusting Holes 3" Apart OUR STRONGEST! Flush Adjusting Steel Nut With Self Centering Pilot Into Tube Which Helps Prevent Lateral Movement Immersion Dipped for Heavy Coating Inside and Out to Prevent Corrosion Compression Load Range* 38,000 lbs. 20,000 lbs. to 8' 4" 4' 8 Extra Strength Zinc Coated Nut & Screw Heavier Gauge Professional Plates Extra Strength Zinc Coated Nut & Screw Larger Diameter Strong 11 Gauge Steel Tubing Zinc Coated Secure Bolt & Nut Connecters Corrosion Resistant Paint Inside & Out Outside Tube is 11 Gauge Heavy Duty High Carbon Steel Designed for Heavy Load Areas Galvanized Bottom Plate - Embossed to Prevent Dishing and Movement of Post Self-Centering 7 16" x¾" 6" TM Plates 4" Temporary support for room additions, remodeling projects. Can be used permanently if used as secondary support All Steel Adjustable Easy To Install South Water Street Ext. Meadville, PA 1633 Phone: Fax: us: info@akronproducts.com 3 pg.

4 FLOOR JACKS 1 Ga. C-84 C-79 C-2 C-3 C-4 C-42 (Two Pack C-4's) ) Mobile Home Jack Adjustment Range 4 ft. 8 in. - 8 ft. 4 in. / 6"-100" 4 ft. 6 in. - 7 ft. 9 in. / 4"-93" 2 ft. 10 in. - 4 ft. 7 in. / 34"-" 1 ft. 7 in. - 3 ft. 0 in. / 19"-36" 1 ft. 0 in. - 1 ft. 3 in. / 12"-1 1 ft. 0 in. - 1 ft. 3 in. / 12"-1 1 ft. 0 in. - 1 ft. 4 in. / 12"-16" 3 2½ O.D. Lower, 2¼ O.D. Upper; 32 x 4 x Plates UPC Compression Load Range* Weight Unit Cube ,000 lbs. to 9,100 lbs. 18,000 lbs. to 11,30 lbs. 18,000 lbs. to 14,000 lbs. 18,000 lbs. to 16,000 lbs. 18,000 lbs. 18,000 lbs. 18,000 lbs. 18 lbs. 16 lbs. 11 lbs. 8 lbs. 4 lbs. 8 lbs. 9 lbs Galvanized Plate - Embossed to Prevent Dishing and Movement of Post. *Compression load is testing to the point of failure. Maximum loads are obtained at minimum extension. To determine safe or allowable loads, consult a licensed engineer. DESIGNED FOR REMODELING PROJECTS For use in projects as temporary or additional support Not intended for permanent, primary support Outside Tube is Heavy Duty High Carbon Steel. Immersion Dipped for Heavy Coating Inside and Out to Prevent Corrosion. Crawl Spaces, Porches and Decks Heavy Load Areas Under Stairs Double Carriage Bolt & Nut for Added Safety! Temporary support for room addition, remodeling projects. Takes the weight of large appliances or heavy load areas. Can be used permanently if used as a secondary support. Corrects sagging floors, supports basement beams and stairwells. Not intended for permanent, primary support. Inside Tube is Heavy Duty High Carbon Steel, With Adjusting Holes 3" Apart. Flush Adjusting Steel Nut With Pilot Into Tube Which Provides Extra Safety Against Accidental Side Pressure. HOMEJACKS MOBILE Adjusts from 12 to16 Adjusting Screw - SAE Galvanized Swivel Plate - Embossed to Prevent Dishing. Stabilizes trailer when parked Stores easily, sets up quickly All Steel Adjustable Easy To Install South Water Street Ext. Meadville, PA 1633 Phone: Fax: us: info@akronproducts.com 4 pg.

5 2011 The Akron Products Company - FLOOR-MONO DESIGNED FOR REMODELING PROJECTS FLOOR JACKS All Steel Adjustable Easy To Install Heavy Load Areas Stairs Crawl Spaces, Porches and Decks Under kitchen areas with granite tops, refrigerator, heavy objects. For temporary additional support. Use for support while mending or replacing primary supports Get Your Merchandise Out FLOOR JACK FREESTANDING MERCHANDISER The4 The Most Popular Sizes! JRD02A Model #: FLOOR JACK DISPLAY/ASSORTMENT (Includes products below + Display Rack) Adjustment Thickness C-84 C-79 C-2 C to to to to Gauge 1 Gauge 1 Gauge 1 Gauge Display Merchandiser with Sign UPC Qty Made in the U.S.A South Water Street Ext. Meadville, PA 1633 Phone: Fax: us: info@akronproducts.com Where Your Customer Can See It! pg.

6 FLOOR JACKS Fig. 1 Floor Jack Installation Instructions Fig. 2 Fig Place flat side of one plate on footing. Put large diameter post on plate with holes on top. Make sure post is exactly vertical and is centered under the beam. (Fig. 1) For Model C4 (12-1 ) Jack skip steps 2 and 4 2. Insert small diameter post inside large post. For maximum height, position small diameter post with holes at bottom. Reverse for shorter applications. (Fig. 2) 3. Turn round nut to top of threads on adjustment screw. Place adjustment screw on top of small diameter post. Tapered side of nut will fit into small diameter post with the shoulder resting on top of post. (Fig. 3) 4. Lift small diameter post to highest possible position. Align holes in posts. Place two bolts through holes and secure with nuts. (Fig. 4). Place plate on top of screw with flat side up. Use adjustable wrench to complete adjustment. (Fig. ) NOTE: MAKE SURE POST IS EXACTLY VERTICAL. Secure plates with proper nails, screws, or bolts. NOTE: For best support under wooden structures place large diameter tube and plate directly under beam. (Fig. 6) To correct sagging floors,place beam under joists, hold in place with two Floor Jacks. Adjust floor jacks one-half turn each week over several weeks. Telescoping jacks should be used for additional support, not the primary means of support. When used in a lifting application, consult a licensed engineer to determine safe allowable load. Fig.4 Fig. WOODEN STRUCTURES Other uses for Floor Jacks Fig. 6 Crawl Spaces, Porches and Decks Stairs Heavy Load Areas South Water Street Ext. Meadville, PA 1633 Phone: Fax: us: info@akronproducts.com 6 pg.

7 FLOOR JACKS Instrucciones de instalación para gato de piso Fig. 1 Fig. 2 Fig Colocar la cara plana de una de las placas sobre el lugar de apoyo. Colocar el poste de diámetro grande sobre la placa, con los agujeros en la parte superior. Hacer después de que es totalmente vertical y se centra en la viga. (Fig. 1) De 12 "-1" Jack saltarse los pasos 2 y 4 2. Insertar el poste de diámetro pequeño dentro del poste grande. Para la altura máxima, posicionar el poste de diámetro pequeño con los agujeros en la parte inferior. Invertir para aplicaciones más cortas. (Fig. 2) 3. Girar la tuerca hasta el extremo de la rosca en el tornillo de ajuste. Colocar el tornillo de ajuste sobre el poste de diámetro pequeño. El lado de menor diámetro de la rosca calzará dentro del poste de diámetro pequeño y el reborde superior quedará apoyado sobre la parte superior del poste. (Fig. 3) 4. Levantar el poste de diámetro pequeño hasta la posición más alta. Alinear los agujeros en los postes. Colocar dos bulones a través de los agujeros y asegurarlos con tuercas. (Fig. 4). Colocar la placa sobre el tornillo con la cara plana hacia arriba. Utilice una llave ajustable para completar el ajuste. (Fig. ) NOTA: ASEGURARSE DE QUE LA POSICIÓN DEL POSTE SEA PERFECTAMENTE VERTICAL. Asegurar las placas con los clavos, tornillos, o bulones adecuados. NOTA: Para un mejor soporte debajo de estructuras de madera, colocar el tubo de diámetro mayor y la placa directamente debajo del tirante. (Fig. 6) Para corregir pisos hundidos, colocar un tirante debajo de las vigas, sostener en su lugar con dos gatos de piso. Ajustar los gatos de piso medio giro por semana durante varias semanas. Gatos telescópicos deben utilizarse para el apoyo adicional, no el principal medio de apoyo. Cuando se usa en una aplicación de elevación, consulte a un ingeniero con licencia para determinar la carga admisible de seguridad. Fig.4 Fig. Madera Structres Otros usos para gatos de piso Fig. 6 Espacios debajo del piso, porches y plataformas Escaleras Áreas con mucho peso South Water Street Ext. Meadville, PA 1633 Phone: Fax: us: info@akronproducts.com 7 pg.

8 FLOOR JACKS Instructions pour l'installation des crics rouleurs Fig. 1 Fig. 2 Fig Placez le côté lisse d'un plat sur le pavement. Mettez le poteau au large diamètre sur le plat avec les trous en haut. Faire message sûr, c'est exactement à la verticale et est centré sous le faisceau. (Fig. 1) Pour 12 "- 1" Jack sauter les étapes 2 et 4 2. Insérez le poteau au petit diamètre au-dedans du large poteau. Pour une hauteur maximum, placez le poteau au petit diamètre avec les trous en bas. Reverser la position pour les utilisations plus courtes. (Fig. 2) 3. Tournez autour de l'écrou au-dessus des fils de la vis de réglage. Placez la vis de réglage sur le poteau de petit diamètre. Le côté conique de l'écrou se logera dans le poteau au petit diamètre avec l'épaulement restant positionné au-dessus du poteau. (Fig. 3) 4.Soulevez le poteau de faible diamètre dans la position plus élevée possible. Alignez les trous dans des poteaux. Placez deux boulons par des trous et les fixez avec des écrous. (Fig. 4). Placez le plat sur la vis, avec le côté lisse vers le haut. Utilisez la clé réglable pour compléter l'ajustement. (Fig. ) ATTENTION: Assurez-vous QUE LE POTEAU EST EXACTEMENT VERTICAL. Sécurisez les plats avec les clous, les vis ou les boulons appropriés. NOTE: Pour un meilleur appui sous les structures en bois, placez le tube et le plat de grand diamètre directement sous le balancier. (Fig. 6) Pour corriger l'affaissement des pavements, placez le balancier sous les poutrelles et tenez-le en place à l'aide des deux crics rouleurs. Ajustez les crics rouleurs un demi-tour chaque semaine pendant plusieurs semaines. Vérins télescopiques doivent être utilisées pour un soutien supplémentaire, et non le principal moyen de soutien. Lorsqu'ils sont utilisés dans une application de levage, consultez un ingénieur agréé de déterminer la charge admissible en toute sécurité. Fig.4 Fig. Structures en bois Autres usages pour les crics rouleurs. Fig. 6 Vides Sanitaires, Vérandas et Terrasses Escaliers Surfaces surchargées South Water Street Ext. Meadville, PA 1633 Phone: Fax: us: info@akronproducts.com 8 pg.

9 MONO POSTS Fully Assembled Self-Contained Unit No Loose Parts. DESIGNEDFOR NEWHOMECONSTRUCTION Standard Series: 1Plate: 4¼"x 7½"x.120 Thick H Series: 1 Plate: 4¼"x7¼" x.120 Thick STANDARD SERIES Used with wood beams H SERIES Used with steel beams Coating Finished with corrosion resistant powder coating that exceeds ASTM-B Plates 1 Plate (Swivel) 4" x 6 x,.120 Thick, 1 Plate 4¼" x 7½" x.120 Thick 1 Tube 3" O.D., 11 Gauge (Also Available in 3 ½" and 4" Diameter) 1Screw 1¼" O.D. 7 Pitch "V" Thread With 4" Adjustment 1Nut 3" O.D. Tapped for 1¼" 7 Pitch Thread Strength Refer to Current ICC-ES Report ICC-ESR-1767 Complies with 2009 IBC and IRC Building Codes Bottom Plate 1 Plate (Swivel): 4"x6 x.120 Thick Coating Finished with corrosion resistant powder coating that exceeds ASTM-B Plates 1 Plate 4¼" x 7¼" x.120 Thick, 1 Plate (Swivel) 4" x 6 x.120 Thick 1 Tube 3" O.D., 11 Gauge (Also Available in 3½" and 4" Diameter) 1Screw 1¼" O.D. 7 Pitch "V" Thread With 4" Adjustment 1Nut 3" O.D. Tapped for 1¼" 7 Pitch Thread Strength Refer to Current ICC-ES Report One person can install in less than minutes. Adjust screw to approximate length needed between beam and footer, where the MONO-POST is to be positioned. Set MONO-POST in a perpendicular position between footer and beam. Make additional screw adjustment until the post is firmly in position. Additional adjustments may be made during construction to keep floor level. Poured concrete floor locks MONO-POST adjustment permanently. 11 gauge MONO- POSTS are available in 3, 3 ½, & 4 inch OD. The 3, 3. and 4 inch models are manufactured in 3" increments up to 12 feet. Schedule 40 MONO-POSTS are also available up to 12 feet. Tamper proof adjustment...mono-post should be positioned with adjustment nut and screw at the footer South Water Street Ext. Meadville, PA 1633 Phone: Fax: us: info@akronproducts.com 9 pg.

10 MONO POSTS Manufacturing Specifications Model: 3" O.D., 11 Gauge ft. 0 in. - 6 ft. 4 in. 6 ft. 3 in. - 6 ft. 7 in. 6 ft. 6 in. - 6 ft. 10 in. 6 ft. 9 in. - 7 ft. 1 in. 7 ft. 0 in. - 7 ft. 4 in. 7 ft. 3 in. - 7 ft. 7 in. 7 ft. 6 in. - 7 ft. 10 in. 7 ft. 9 in. - 8 ft. 1 in. 8 ft. 0 in. - 8 ft. 4 in. 8 ft. 3 in. - 8 ft. 7 in. 8 ft. 6 in. - 8 ft. 10 in. 8 ft. 9 in. - 9 ft. 1 in. 9 ft. 0 in. - 9 ft. 4 in. 9 ft. 3 in. - 9 ft. 7 in. 9 ft. 6 in. - 9 ft. 10 in. 9ft.9in.-10ft.1in. 10 ft. 0 in ft. 4 in. 10 ft. 3 in ft. 7 in. 10 ft. 6 in ft. 10 in. 10 ft. 9 in ft. 1 in. 11 ft. 0 in ft. 4 in. 11 ft. 3 in ft. 7 in. 11 ft. 6 in ft. 10 in. 11 ft. 9 in ft. 1 in. 6 ft. 0 in. - 6 ft. 4 in. 6 ft. 3 in. - 6 ft. 7 in. 6 ft. 6 in. - 6 ft. 10 in. 6 ft. 9 in. - 7 ft. 1 in. 7 ft. 0 in. - 7 ft. 4 in. 7 ft. 3 in. - 7 ft. 7 in. 7 ft. 6 in. - 7 ft. 10 in. 7 ft. 9 in. - 8 ft. 1 in. 8 ft. 0 in. - 8 ft. 4 in. 8 ft. 3 in. - 8 ft. 7 in. 8 ft. 6 in. - 8 ft. 10 in. 8 ft. 9 in. - 9 ft. 1 in. 9 ft. 0 in. - 9 ft. 4 in. 9 ft. 3 in. - 9 ft. 7 in. 9 ft. 6 in - 9 ft. 10 in. 9ft.9in.-10ft.1in. 10 ft. 0 in ft. 4 in. 10 ft. 3 in ft. 7 in. 10 ft. 6 in ft. 10 in. 10 ft. 9 in ft. 1 in. 11 ft. 0 in ft. 4 in. 11 ft. 3 in ft. 7 in. 11 ft. 6 in ft. 10 in. 11 ft. 9 in ft. 1 in. 72" - 76" 7" - 79" 78" - 82" 81" - 8" 84" - 88" 87" - 91" 90" - 94" 93" - 97" 96" - 100" 99" - 103" 102" - 106" 10" - 109" 108" - 112" 111" - 11" 114" - 118" 117" - 121" 120" - 124" 123" - 127" 126" - 130" 129" - 133" 132" - 136" 13" - 139" 138" - 142" 141" - 14" 72" - 76" 7" - 79" 78" - 82" 81" - 8" 84" - 88" 87" - 91" 90" - 94" 93" - 97" 96" - 100" 99" - 103" 102" - 106" 10" - 109" 108" - 112" 111" - 11" 114" - 118" 117" - 121" 120" - 124" 123" - 127" 126" - 130" 129" - 133" 132" - 136" 13" - 139" 138" - 142" 141" - 14" Allowable Strength Load Lbs. (ASD)* 13,00 13,300 13,000 12,700 12,400 12,100 11,800 11,00 11,200 10,900 10,600 10,200 9,900 9,600 9,300 9,000 8,700 8,300 8,000 7,700 7,400 7,100 6,800 6,600 17,000 16,800 16,00 16,300 16,000 1,700 1,00 1,200 14,900 14,600 14,300 14,000 13,700 13,400 13,100 12,800 12,400 12,100 11,800 11,00 11,200 10,800 10,00 10,200 Design Strength Load Lbs. (LRFD)* 20,300 19,900 19,00 19,100 18,600 18,200 17,700 17,300 16,800 16,300 1,900 1,400 14,900 14,400 14,000 13,00 13,000 12,00 12,100 11,600 11,100 10,700 10,200 10,000 Model # Adjustment Range UPC M Series Weight Unit Cube Model: 3½" O.D., 11 Gauge ICC-ESR Complies with 2009 IBC and IRC Building Codes New 11 gauge, carbon steel tubing, minimum yield strength of 42,000 psi. complies with ASTM A00. Meets all FHA/HUD requirements. Finished with corrosion resistant coating that exceeds ASTM-B One year limited warranty. Standard Tube End Plate: 4¼" x 7½" x.120" / H Series: 4¼ x 7¼ x.120" - Adj./Swivel End Plate 4" x 6 x.120" 2,600 2,200 24,800 24,00 24,100 23,600 23,200 22,800 22,400 21,900 21,00 21,000 20,600 20,100 19,600 19,200 18,700 18,200 17,700 17,300 16,800 16,300 1,800 1, lbs. 29 lbs. 30 lbs. 31 lbs. 32 lbs. 33 lbs. 34 lbs. 3 lbs. 3 lbs. 36 lbs. 37 lbs. 38 lbs. 39 lbs. 40 lbs. 41 lbs. 42 lbs. 43 lbs. 47 lbs. 49 lbs. 0 lbs. 1 lbs. 2 lbs. 3 lbs. 4 lbs. 33 lbs. 34 lbs. 3 lbs. 36 lbs. 37 lbs. 38 lbs. 39 lbs. 40 lbs. 41 lbs. 42 lbs. 44 lbs. 4 lbs. 46 lbs. 47 lbs. 48 lbs. 49 lbs. 0 lbs. 2 lbs. 2 lbs. 2 lbs. 3 lbs. 4 lbs. lbs. 6 lbs. *Consult a registered professional engineer for column selection based on ASD or LRFD methodologies Standard Tube End Plate: 4¼" x 7½" x.120" / H Series: 4¼ x 7¼ x.120" - Adj./Swivel End Plate 4" x 6 x.120" South Water Street Ext. Meadville, PA 1633 Phone: Fax: us: info@akronproducts.com pg. 10

11 MONO POSTS Manufacturing Specifications Model: 4" O.D., 11 Gauge Model # ICC-ESR Complies with 2009 IBC and IRC Building Codes New 11 gauge, carbon steel tubing, minimum yield strength of 42,000 psi. complies with ASTM A00. Meets all FHA/HUD requirements. Finished with corrosion resistant coating that exceeds ASTM-B One year limited warranty. Adjustment Range 6 ft. 0 in. - 6 ft. 4 in. 6 ft. 3 in. - 6 ft. 7 in. 6 ft. 6 in. - 6 ft. 10 in. 6 ft. 9 in. - 7 ft. 1 in. 7 ft. 0 in. - 7 ft. 4 in. 7 ft. 3 in. - 7 ft. 7 in. 7 ft. 6 in. - 7 ft. 10 in. 7 ft. 9 in. - 8 ft. 1 in. 8 ft. 0 in. - 8 ft. 4 in. 8 ft. 3 in. - 8 ft. 7 in. 8 ft. 6 in. - 8 ft. 10 in. 8 ft. 9 in. - 9 ft. 1 in. 9 ft. 0 in. - 9 ft. 4 in. 9 ft. 3 in. - 9 ft. 7 in. 9 ft. 6 in. - 9 ft. 10 in. 9ft.9in.-10ft.1in. 10 ft. 0 in ft. 4 in. 10 ft. 3 in ft. 7 in. 10 ft. 6 in ft. 10 in. 10 ft. 9 in ft. 1 in. 11 ft. 0 in ft. 4 in. 11 ft. 3 in ft. 7 in. 11 ft. 6 in ft. 10 in. 11ft.9in.-12ft.1in 6 ft. 0 in. - 6 ft. 4 in. 6 ft. 3 in. - 6 ft. 7 in. 6 ft. 6 in. - 6 ft. 10 in. 6 ft. 9 in. - 7 ft. 1 in. 7 ft. 0 in. - 7 ft. 4 in. 7 ft. 3 in. - 7 ft. 7 in. 7 ft. 6 in. - 7 ft. 10 in. 7 ft. 9 in. - 8 ft. 1 in. 8 ft. 0 in. - 8 ft. 4 in. 8 ft. 3 in. - 8 ft. 7 in. 8 ft. 6 in. - 8 ft. 10 in. 8 ft. 9 in. - 9 ft. 1 in. 9 ft. 0 in. - 9 ft. 4 in. 9 ft. 3 in. - 9 ft. 7 in. 9 ft. 6 in. - 9 ft. 10 in. 9ft.9in.-10ft.1in. 10 ft. 0 in ft. 4 in. 10 ft. 3 in ft. 7 in. 10 ft. 6 in ft. 10 in. 10 ft. 9 in ft. 1 in. 11 ft. 0 in ft. 4 in. 11 ft. 3 in ft. 7 in. 11 ft. 6 in ft. 10 in. 11 ft. 9 in ft. 1 in. Standard Tube End Plate: 4¼" x 7½" x.120" / H Series: 4¼ x 7¼ x.120" - Adj./Swivel End Plate 4" x 6 x.120" 72" - 76" 7" - 79" 78" - 82" 81" - 8" 84" - 88" 87" - 91" 90" - 94" 93" - 97" 96" - 100" 99" - 103" 102" - 106" 10" - 109" 108" - 112" 111" - 11" 114" - 118" 117" - 121" 120" - 124" 123" - 127" 126" - 130" 129" - 133" 132" - 136" 13" - 139" 138" - 142" 141" - 14" 72" - 76" 7" - 79" 78" - 82" 81" - 8" 84" - 88" 87" - 91" 90" - 94" 93" - 97" 96" - 100" 99" - 103" 102" - 106" 10" - 109" 108" - 112" 111" - 11" 114" - 118" 117" - 121" 120" - 124" 123" - 127" 126" - 130" 129" - 133" 132" - 136" 13" - 139" 138" - 142" 141" - 14" Allowable Strength Load Lbs. (ASD)* 20,400 20,200 20,000 19,700 19,00 19,300 19,000 18,700 18,00 18,200 17,900 17,600 17,400 17,100 16,800 16,00 16,200 1,900 1,600 1,300 14,900 14,600 14,300 14,000 29,300 28,800 28,400 27,900 27,400 26,900 26,400 2,900 2,400 24,900 24,400 23,800 23,300 22,700 22,200 21,600 21,000 20,00 19,900 19,300 18,800 18,200 17,600 17,100 Design Strength Load Lbs. (LRFD)* 30,700 30,400 30,000 29,700 29,300 28,900 28,600 28,200 27,800 27,400 26,900 26,00 26,100 2,700 2,200 24,800 24,300 23,900 23,400 22,900 22,00 22,000 21,00 21,000 UPC M Series Weight Unit Cube 44,000 43,300 42,600 41,900 41,200 40,00 39,700 39,000 38,200 37,400 36,600 3,800 3,000 34,100 33,300 32,00 31,600 30,800 29,900 29,100 28,200 27,400 26,00 2, lbs. 38 lbs. 40 lbs. 41 lbs. 42 lbs. 43 lbs. 4 lbs. 46 lbs. 47 lbs. 48 lbs. 0 lbs. 1 lbs. 2 lbs. 3 lbs. lbs. 6 lbs. 7 lbs. 8 lbs. 60 lbs. 61 lbs. 62 lbs. 63 lbs. 64 lbs. 66 lbs. Model: Schedule 40 Series Standard Tube End Plate: / H Series: 4¼ x 7¼ x - Adj./Swivel End Plate lbs. 4 lbs. 6 lbs. 8 lbs. 60 lbs. 62 lbs. 64 lbs. 6 lbs. 67 lbs. 69 lbs. 71 lbs. 73 lbs. 7 lbs. 77 lbs. 79 lbs. 81 lbs. 83 lbs. 8 lbs. 87 lbs. 89 lbs. 90 lbs. 92 lbs. 94 lbs. 96 lbs. *Consult a registered professional engineer for column selection based on ASD or LRFD methodologies ¼" x 7½" x.120".120" 4" x 6 x.120" South Water Street Ext. Meadville, PA 1633 Phone: Fax: us: info@akronproducts.com pg. 11

12 MONO POSTS Installation Instructions Fig. 1 Fig. 2 Installation Time: Approximately 1 Minutes Tools Required: None 1. Choose the correct size and strength Mono-Post for the project based on construction documents (Fig.1) 2. Adjust screw to slightly short of the length needed between footer and load carrying beam at installation location 3. Place Mono-Post vertically between footer and beam with the adjustment nut and screw on the footer (adjustable end down) 4. Adjust screw to wedge the Mono-Post between footer and beam, tighten until Mono-Post is firmly centered directly under the load carrying beam and the footer below (Fig. 2). Additional screw adjustments may be made during construction to keep floor level 6. Poured concrete basement floor permanently locks Mono-Post adjustment (Fig.3) TAMPERPROOF ADJUSTMENT: MONO-POST SHOULD BE POSITIONED WITH ADJUSTMENT NUT AND SCREW AT THE FOOTER. Note: Always consult Local Building Codes for specific installation requirements in your area. Fig South Water Street Ext. Meadville, PA 1633 Phone: Fax: us: info@akronproducts.com pg. 12

13 FIXED LENGTH COLUMNS Fully Assembled Self-Contained Unit No Loose Parts. Plate Specification 9 16" 13 x 16" Construction Features 7½" 4¼" Standard Plate Finished with corrosion resistant powder coating that exceeds ASTM-B117-8 No loose parts...columns are shipped complete with one plate welded on...one plate firmly attached to welded plate. Option - you may specify both plates welded on or both plates loose. Standard column is 3" O.D., 11 Ga. Column wall prime high carbon, heavy duty steel. Identification label clearly shows size. Any length - fixed length columns are available in custom lengths up to 12 feet to fit any need. ICC-ESR-1767 Complies with 2009 IBC and IRC Building Codes Easy to Install Measure opening to be spanned. Order length column to fit. (See product list for most popular sizes). Place column on footing, mark and cut column (if neccessary). Attach top plate, shim if necessary and secure with bolts South Water Street Ext. Meadville, PA 1633 Phone: Fax: us: info@akronproducts.com pg. 13

14 Fixed Length Columns ICC-ESR Complies with 2009 IBC and IRC Building Codes Manufacturing New 11 gauge, carbon steel tubing, minimum yield strength of 42,000 psi. complies with ASTM A00. Meets all FHA/HUD Specifications requirements. Finished with corrosion resistant coating that exceeds ASTM-B One year limited warranty. 3" Outside Diameter 11 Gauge Standard Plates ( 4¼" x 7½") Allowable Design Model # Adjustment Range UPC M Series Strength Load Strength Load Weight Unit Lbs. (ASD)* Lbs. (LRFD)* Cube ft. 0 in. (72") 6 ft. 3 in. (7 ) 6 ft. 6 in. (78") 6 ft. 9 in (81 ) 7 ft. 0 in. (84") 7 ft. 3 in. (87 ) 7 ft. 6 in. (90") 7 ft. 9 in. (93 ) 8 ft. 0 in. (96") 8 ft. 3 in. (99 ) 8 ft. 6 in. (102") 8 ft. 9 in. (10 ) 9 ft. 0 in. (108") 9 ft. 3 in. (111 ) 9 ft. 6 in. (114") 9 ft. 9 in. (117 ) 10 ft. 0 in. (120") 12 ft. 0 in. (144") 6 ft. 0 in. (72") 6 ft. 6 in. (78") 7 ft. 0 in. (84") 7 ft. 6 in. (90") 8 ft. 0 in. (96") 8 ft. 6 in. (102") 9 ft. 0 in. (108") 9 ft. 6 in. (114") 10 ft. 0 in. (120") 12 ft. 0 in. (144") 6 ft. 0 in. (72") 6 ft. 6 in. (78") 7 ft. 0 in. (84") 7 ft. 6 in. (90") 8 ft. 0 in. (96") 8 ft. 6 in. (102") 9 ft. 0 in. (108") 9 ft. 6 in. (114") 10 ft. 0 in. (120") 12 ft. 0 in. (144") ,800 18,400 17,900 17,400 16,900 16,400 1,900 1,400 14,900 14,400 13,900 13,400 12,900 12,400 11,900 11,400 11,000 7,700 24,000 23,100 22,200 21,200 20,200 19,200 18,200 17,200 16,200 12,400 29,100 28,200 27,400 26,400 2,00 24,00 23,600 22,600 21,600 17,00 28,300 27,600 26,900 26,100 2,400 24,600 23,900 23,100 22,300 21,600 20,800 20,100 19,300 18,600 17,900 17,200 16,00 11,600 36,100 34,700 33,300 31,900 30,400 28,900 27,400 2,900 24,300 18,600 43,700 42,400 41,100 39,800 38,300 36,900 3,400 33,900 32,400 26, lbs. 27 lbs. 28 lbs. 29 lbs. 30 lbs. 31 lbs. 32 lbs. 32 lbs. 33 lbs. 34 lbs. 3 lbs. 36 lbs. 37 lbs. 38 lbs. 39 lbs. 40 lbs. 41 lbs. 4 lbs. 3½ Outside Diameter 11 Gauge Standard Plates ( 4¼" x 7½") 30 lbs. 32 lbs. 34 lbs. 36 lbs. 38 lbs. 41 lbs. 43 lbs. 4 lbs. 47 lbs. 6 lbs. 4 Outside Diameter 11 Gauge Standard Plates ( 4¼" x 7½") 34 lbs. 36 lbs. 39 lbs. 41 lbs. 44 lbs. 46 lbs. 49 lbs. 1 lbs. 4 lbs. 64 lbs. *Consult a registered professional engineer for column selection based on ASD or LRFD methodologies South Water Street Ext. Meadville, PA 1633 Phone: Fax: us: info@akronproducts.com pg. 14

15 rabber The TM Made in USA Saddle Plate for Laminated (LVL) or Dimensional Lumber Beams Part No. SP " W x " H x 8" L Part No. SP3916 Some municipalities require the use of a saddle plate for dimensional lumber or LVL beams in conjunction with Adjustable Steel Columns. 3 8" W x " H x 8" L Effective April 1, 2009 if you are using a laminated (LVL) or dimensional lumber beam, you must use a saddle plate in conjunction with Adjustable Steel Columns per Wisconsin UDC (Uniform Dwelling Code). Com21.22(3)(d) Lateral restraint for all wood beams shall be provided at all columns using a saddle plate or other approved connection where the beam meets one of the following conditions: 1. The beam is not restrained at both ends. 2. The beam is more than 11¼ inches deep using actual measurement. Note: A saddle plate supports the beam on the bottom and allows for the through connection of fasteners into the side of the beam. Part No. Dimensions UPC SP716 SP " W x " H x 8" L 3 8" W x " H x 8" L Shelf Pack Wt./pc lbs. 3.7 lbs. Manufactured in the U.S.A. by The TAPCO Companies, Meadville, PA. pg. Made in the U.S.A The Akron Products Company - FLOOR-MONO

16 All Steel WINDOW WELLS Made of 22 Gauge Galvanized Steel Deep Corrugations for Extra Strength Top Fully Rolled for Rigidity and Safety Wide Pre-Punched Flat Mounting Flanges Model # Height/Style UPC Bundle Weight Unit Cube Model # Height/Style UPC Bundle Weight Unit Cube AW R12 AW R1 AW R18 AW R24 AW R30 AW R36 AW R48 12 Vent 12" Round 1" Round 18" Round 24 Round 30 Round 36 Round 48 Round 12 Round lbs. 43 lbs. 4 lbs. 9 lbs. 72 lbs. 81 lbs. 12 lbs. 3 lbs AW S12 AW S1 AW S18 AW S24 AW S30 AW S36 AW S48 12" Square 1" Square 18" Square 24 Square 30 Square 36 Square 48 Square lbs. 38 lbs. 41 lbs. 63 lbs. 74 lbs. 9 lbs. 12 lbs Round 37" wide,16" projection - accomodates 3" to 40" width Square 37" wide, 13" projection Made of 22 Gauge Galvanized Steel Deep Corrugations for Extra Strength Top Fully Rolled for Rigidity and Safety Wide Pre-Punched Flat Mounting Flanges Easily and Quickly Installed Single Piece Construction up to 36" Height No Welding on Any Models Designed to Provide More Daylight Standard Heights for Both Round & Square (approx.): 12", 1", 18", 24", 30", 36", 48". Standard package: per bundle South Water Street Ext. Meadville, PA 1633 Phone: Fax: us: info@akronproducts.com pg. 16

17

18 ESR-1766 Most Widely Accepted and Trusted Page 2 of

19 ESR-1766 Most Widely Accepted and Trusted Page 3 of

20 ESR-1766 Most Widely Accepted and Trusted Page 4 of

21 ESR-1766 Most Widely Accepted and Trusted Page of Top Plate Spot Weld Spot Weld 3", 3½" or 4" Diameter Tubing Spot Weld Spot Weld Swivel Plate ADJUSTABLE COLUMN FIXED LENGTH COLUMN 7½" 7½" SWIVEL PLATE 4 ¼" 2 ⅛" 4 ¼" STANDARD PLATE "H" PLATE NUT FIGURE 1 SCREW *These Drawings are for illustration purposes only. They are not intended for use as construction documents for the purpose of design, fabrication or erection. The Akron Products Company

INSTALLATION INSTRUCTION Bliss - Vanities & Wall Sconces WS-79622

INSTALLATION INSTRUCTION Bliss - Vanities & Wall Sconces WS-79622 WS-79622 WARNING IMPORTANT: NEVER attempt any work without shutting off the electricity. - Read all instructions before installing. - System is intended for installation by a qualified electrician in accordance

More information

Maximum Weight Capacity: Top Glass Shelf: 110 lbs. MODEL E113E ASSEMBLY INSTRUCTIONS. Important! Read all warnings before starting assembly.

Maximum Weight Capacity: Top Glass Shelf: 110 lbs. MODEL E113E ASSEMBLY INSTRUCTIONS. Important! Read all warnings before starting assembly. Maximum Weight Capacity: Top Glass Shelf: 110 lbs. MODEL E113E ASSEMBLY INSTRUCTIONS Important! Read all warnings before starting assembly. READ THIS FIRST! Read all of the warnings and cautions contained

More information

INSTALLATION INSTRUCTION Vanities & Wall Sconce WS-85618

INSTALLATION INSTRUCTION Vanities & Wall Sconce WS-85618 WS-85618 WARNING IMPORTANT: NEVER attempt any work without shutting off the electricity. - Read all instructions before installing. - System is intended for installation by a qualified electrician in accordance

More information

MODEL VW2960C ASSEMBLY INSTRUCTIONS

MODEL VW2960C ASSEMBLY INSTRUCTIONS MODEL VW2960C ASSEMBLY INSTRUCTIONS Important! Read all warnings before starting assembly. READ THIS FIRST! Read all of the warnings and cautions contained in this manual before assembly. Do not attempt

More information

INSTALLATION INSTRUCTION Bollard Light 12V

INSTALLATION INSTRUCTION Bollard Light 12V Bollard Light 12V 6611/6621/6631/6641/6651 SAFETY INSTRUCTION IMPORTANT: NEVER attempt any work without shutting off the electricity. Read all instructions before installing. System is intended for installation

More information

Assembly & operating VIDEOS online at: Les VIDÉOS d assemblage et d opération en ligne au:

Assembly & operating VIDEOS online at: Les VIDÉOS d assemblage et d opération en ligne au: Assembly & operating VIDEOS online at: Les VIDÉOS d assemblage et d opération en ligne au: http://murphycube.com 1A Parts List Liste des piéces Wood Block Block Slats Lattes x 3 Arm (Left Hand) Bras (côté

More information

INSTALLATION INSTRUCTION Aether 2 Shallow Recessed Housing

INSTALLATION INSTRUCTION Aether 2 Shallow Recessed Housing SAFETY INSTRUCTIONS IMPORTANT: NEVER attempt any work without shutting off the electricity. Read all instructions before installing. System is intended for installation by a qualified electrician in accordance

More information

INSTALLATION INSTRUCTION Aether 3.5 Color Tunable LED Downlight

INSTALLATION INSTRUCTION Aether 3.5 Color Tunable LED Downlight SAFETY INSTRUCTION IMPORTANT: NEVER attempt any work without shutting off the electricity. Read all instructions before installing. System is intended for installation by a qualified electrician in accordance

More information

ORDERING: Specify size, figure number, description, nominal pipe size or special O.D. and C-to-C dimension. C - C LOAD lb.

ORDERING: Specify size, figure number, description, nominal pipe size or special O.D. and C-to-C dimension. C - C LOAD lb. Fig. 2110 www.pipingtech.com/fig2110 Sway Strut with 4 of Adjustment Engineered spring supports option 1 option 2 ORDERING: Specify size, figure number, description, nominal pipe size or special O.D. and

More information

Spun Bay Installation Standard Version (non dimmable), Hook Mount

Spun Bay Installation Standard Version (non dimmable), Hook Mount Spun Bay Installation Standard Version (non dimmable), Hook Mount WARNING: Make sure that all power is turned off while installing fixture. Do not turn power on until fixture is completely installed. Turn

More information

Captivate Illuminated Mirror Light

Captivate Illuminated Mirror Light ENGLISH WARNINGS & SAFETY INFORMATION: PLEASE READ CAREFULLY FRANÇAIS MISES EN GARDE ET SÉCURITÉ: SE IL VOUS PLAÎT LIRE ATTENTIVEMENT WARNING: RISK OF FIRE OR ELECTRIC SHOCK. LUMINAIRE WIRING AND ELECTRICAL

More information

01 Manillas y tiradores encastrables Flush levers & sliding door pull handles Garnitures de portes coulissantes. Material: AISI 304

01 Manillas y tiradores encastrables Flush levers & sliding door pull handles Garnitures de portes coulissantes. Material: AISI 304 for doors 01 Manillas y tiradores encastrables Flush levers & sliding door pull handles Garnitures de portes coulissantes Material: i-4500 cod. backset 53105 70 1 universal design 90 R2,5 180 Incluye

More information

Specification Grade Contemporary Wall Mount/Technical Installation Data

Specification Grade Contemporary Wall Mount/Technical Installation Data AVAILABLE CONFIGURATIONS RECESSED MOUNT SURFACE MOUNT MOUNTING REQUIREMENTS A. Recessed Mount: Minimum 4-Gang Box, 1-5/8 in. Deep (72.8 Cubic Inches) with 4-Gang Box Cover (20.3 Cubic Inches) B. Surface

More information

ESR-1414 Reissued October 1, 2011 This report is subject to renewal in one year.

ESR-1414 Reissued October 1, 2011 This report is subject to renewal in one year. ICC-ES Evaluation Report www.icc-es.org (00) 23-657 (562) 699-053 ESR-11 Reissued October 1, 2011 This report is subject to renewal in one year. A Subsidiary of the International Code Council DIVISION:

More information

Index. Primary components - back sections Composantes principales - traverses ou meneaux

Index. Primary components - back sections Composantes principales - traverses ou meneaux Thermally broken Split mullion curtain wall - Capped and SSG 2 /2" (63.5mm) profile. Available in 5 /4"(33.4mm) and 6 5/8"(68.3mm) depths. Mur-rideau à meneaux en deux sections avec bris thermique.vss

More information

NOTE: THE ELSPAFOT AND ELSPAFOTH MODELS HAVE THE SAME MEASURES

NOTE: THE ELSPAFOT AND ELSPAFOTH MODELS HAVE THE SAME MEASURES TELESCOPIC ARM FOR FORKLIFT LIFTING ARM FOR FORKLIFT CUSTOM MADE BRAS TÉLÉSCOPIQUE À FIXATION SUR FOURCHES DE CHARIOT ÉLÉVATEUR Hydraulic extension for ELSPAFOTH type On demand Extension hydraulique pour

More information

FITTING INSTRUCTIONS FOR CP0404BL/WH NO-CUT AERO CRASH PROTECTORS HUSQVARNA 701 ENDURO/SUPERMOTO 2016-

FITTING INSTRUCTIONS FOR CP0404BL/WH NO-CUT AERO CRASH PROTECTORS HUSQVARNA 701 ENDURO/SUPERMOTO 2016- FITTING INSTRUCTIONS FOR BL/WH NO-CUT AERO CRASH PROTECTORS HUSQVARNA 701 ENDURO/SUPERMOTO 2016- Page 1 PICTURE A PICTURE B REAR OF BIKE FRONT OF BIKE PICTURE C THIS KIT CONTAINS THE ITEMS PICTURED AND

More information

PVC FOOT VALVE SKU: CV4674

PVC FOOT VALVE SKU: CV4674 SKU: CV4674 PVC-U Foot Check Valve Socket and BSP PVC-U Fuß Rückschlagventil Sockel und BSP PVC-U Pie válvula de retención del zócalo y BSP PVC-U pied Clapet Socket et BSP PVC Foot Check Valve - Socket

More information

KUB T120. Kitchen fans. Caisson de ventilation. Küchenabluftboxen. Extractor de cocina KITCHEN FANS

KUB T120. Kitchen fans. Caisson de ventilation. Küchenabluftboxen. Extractor de cocina KITCHEN FANS Kitchen fans Caisson de ventilation Küchenabluftboxen Extractor de cocina Kitchen exhaust units are used for installation where the air is slightly greasy or the air temperature is up to 120 C. Typical

More information

Cable Cubby 1202 and 1402 Installation Guide

Cable Cubby 1202 and 1402 Installation Guide Cable Cubby 0 and 40 Installation Guide IMPORTANT: Go to www.extron.com for the complete user guide, installation instructions, and specifications. This guide provides instructions for an experienced technician

More information

All Terrain crane 90 tons

All Terrain crane 90 tons All Terrain crane tons liebherr ltm /1 BOOM LENGTHS: to JB LENGTHS: to JB OFFSETS: - - NOTES: portland office:.8.1 seattle office: 8 Technical Data Caractéristiques techniques LTM/1 Mobile Crane Grue automotrice

More information

Mobile Crane/Grue mobile LTM

Mobile Crane/Grue mobile LTM Mobile Crane/Grue mobile LM 1090-4.2 Preliminary Préliminaire ALL-ROUNDER Ready for anything max ft 110 USt 197 ft 203 ft ft 249 ft Mobile Crane/Grue mobile LM 1090-4.2 197 ft NZK K 31 ft 52 ft m 8.4 ft

More information

DIVISION: METALS SECTION: STEEL DECKING REPORT HOLDER: CONSOLIDATED SYSTEMS, INC. (CSi )

DIVISION: METALS SECTION: STEEL DECKING REPORT HOLDER: CONSOLIDATED SYSTEMS, INC. (CSi ) 0 ICC-ES Report ICC-ES (800) 423-6587 (562) 699-0543 www.icc-es.org 000 Most Widely Accepted and Trusted ESR-2839 Reissued 05/2015 This report is subject to renewal 05/2016. DIVISION: 05 00 00 METALS SECTION:

More information

Use, Care and Installation Guide Guide d utilisation, d entretien et d installation Guía de instalación, uso y mantenimiento.

Use, Care and Installation Guide Guide d utilisation, d entretien et d installation Guía de instalación, uso y mantenimiento. Use, Care and Installation Guide Guide d utilisation, d entretien et d installation Guía de instalación, uso y mantenimiento Ceiling Hood Models SUT950 SUT951 *** BEFORE INSTALLATION *** ENSURE THERE IS

More information

FITTING INSTRUCTIONS FOR CP0393BL AERO CRASH PROTECTORS SUZUKI GSX-S

FITTING INSTRUCTIONS FOR CP0393BL AERO CRASH PROTECTORS SUZUKI GSX-S Page1 FITTING INSTRUCTIONS FOR BL AERO CRASH PROTECTORS SUZUKI GSX-S 1000 2015- PICTURE A PICTURE B REAR OF BIKE FRONT OF BIKE PICTURE C THIS KIT CONTAINS THE ITEMS PICTURED AND LABELLED BELOW. DO NOT

More information

INSTALLATION INSTRUCTIONS SUPERPLANE 2.5. Suspended. A nd Avenue, Unit 1 Oakland, CA P E W alwusa.

INSTALLATION INSTRUCTIONS SUPERPLANE 2.5. Suspended. A nd Avenue, Unit 1 Oakland, CA P E W alwusa. INSTALLATION INSTRUCTIONS SUPERPLANE 2.5 Suspended A 1035 22nd Avenue, Unit 1 Oakland, CA 94606 P 510.489.2530 E TalkToUs@alwusa.com W alwusa.com SP2.5S - Safety & Warnings! 1. Read all instructions. 2.

More information

DIVISION: METALS SECTION: COLD-FORMED METAL FRAMING REPORT HOLDER: WARE INDUSTRIES D/B/A MARINO\WARE

DIVISION: METALS SECTION: COLD-FORMED METAL FRAMING REPORT HOLDER: WARE INDUSTRIES D/B/A MARINO\WARE 0 Most Widely Accepted and Trusted ICC-ES Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-3578 Reissued 0/206 This report is subject to renewal 0/208. DIVISION: 05 00 00 METALS SECTION:

More information

western for products manufactured in White City, Oregon

western for products manufactured in White City, Oregon western VERSA-LAM SPECIFIER Guide for products manufactured in White City, Oregon Western VERSA-LAM Guide 11/29/2012 2 VERSA-LAM Products An Introduction to VERSA-LAM Products When you specify VERSA-LAM

More information

STRIKE STRIKE STRIKE. JULY 1 st 2015

STRIKE STRIKE STRIKE. JULY 1 st 2015 69 69 STRIKE STRIKE STRIKE Strike is an innovative system for creating aluminum shelves for cabinets and closets. The no tool assembly joints system allows you to build shelves in just a few minutes. Every

More information

INSTALLATION INSTRUCTIONS. Double Wall, Drain Valve, BSPT. Torque Wrench w/ 100 to 150 ft-lbs. Setting

INSTALLATION INSTRUCTIONS. Double Wall, Drain Valve, BSPT. Torque Wrench w/ 100 to 150 ft-lbs. Setting A1004EVR Spill Containment Direct Burial Application INSTALLATION INSTRUCTIONS Permanent Identification: Month/Year of Manufacture Model # Model Numbers A1004EVR-215A A1004EVR-215AB A1004EVR-215S A1004EVR-215SB

More information

HIT PRODUCTS CORPORATION

HIT PRODUCTS CORPORATION 17 15 12 10 8 6 4 PROLINE ADJUSTABLE ARC NOZZLES SPANISH Available in 4, 6, 8, 10, 12, 15 and 17 radius Adjustable from 20 to 360 degrees Matched precipitation rates Color coded for easy radius identification

More information

Trusted ICC ES. Conformity! Look. Evaluation. ICC-ES Evaluation

Trusted ICC ES. Conformity! Look. Evaluation. ICC-ES Evaluation 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.orgg ESR 3445 Reissued 10/2016 This report is subject to renewal 10/2018. DIVISION: 06 00

More information

DIVISION: METALS SECTION: STEEL DECKING SECTION: STEEL FLOOR DECKING SECTION: STEEL ROOF DECKING REPORT HOLDER:

DIVISION: METALS SECTION: STEEL DECKING SECTION: STEEL FLOOR DECKING SECTION: STEEL ROOF DECKING REPORT HOLDER: 0 ICC-ES Report ICC-ES (800) 423-6587 (562) 699-0543 www.icc-es.org 000 Most Widely Accepted and Trusted ESR-1735 Reissued 04/2015 This report is subject to renewal 03/2016 DIVISION: 05 00 00 METALS SECTION:

More information

In this kit there should be: 1 x Engine Case Cover (ECC0085) 2 x M6x28mm long button head bolts PLEASE READ THESE INSTRUCTIONS FULLY BEFORE STARTING

In this kit there should be: 1 x Engine Case Cover (ECC0085) 2 x M6x28mm long button head bolts PLEASE READ THESE INSTRUCTIONS FULLY BEFORE STARTING FITTING INSTRUCTIONS FOR ECC0085 LHS WATER PUMP COVER TO FIT ALL WATER COOLED DUCATI S REMOVE REMOVE In this kit there should be: 1 x Engine Case Cover (ECC0085) 2 x M6x28mm long button head bolts PLEASE

More information

INSTALLATION INSTRUCTIONS FOR SOLID VENT KIT PART NUMBER

INSTALLATION INSTRUCTIONS FOR SOLID VENT KIT PART NUMBER INSTALLATION INSTRUCTIONS FOR SOLID VENT KIT PART NUMBER 239-47810-00 WARNING The vent-air intake system must be properly installed. Failure to properly install the vent-air intake system could result

More information

Slot diffusers Type ALS

Slot diffusers Type ALS Slot diffusers Type Slot diffuser Slot diffuser for ceiling installation type. The frontal face of the diffuser has an attractive design with extruded aluminum sections. diffusers can be installed in rooms

More information

Innovative tools for winding equipment! 2018 Catalogue

Innovative tools for winding equipment! 2018 Catalogue Innovative tools for winding equipment! 2018 Catalogue 1 -Table of contents- Table of contents p.2 Replacement parts & Custom equipment p.3 WINDING MACHINERY p.4 Manual light duty p.4 ELD electric light

More information

An extended familly of high output projectors

An extended familly of high output projectors HOT SPOTS An extended familly of high output projectors PICO X021 PIXEL X026 NANO X033 VOXEL X064 TURBINE X045 POINT X044 Big punch Little package Robust and modern Same punch Different package Guiding

More information

Ford Fabricated Steel Products

Ford Fabricated Steel Products Ford Fabricated Steel Products Section N2 12/2000 The Ford Meter Box Co., Inc. 775 Manchester Avenue, P.O. Box 443, Wabash, Indiana, USA 46992-0443 Telephone: 219/563-3171 FAX: 1-800-826-3487 Overseas

More information

Wilo TOP-S, TOP-Z Installation and operating instructions Notice de montage et de mise en service Instrucciones de instalación y funcionamiento

Wilo TOP-S, TOP-Z Installation and operating instructions Notice de montage et de mise en service Instrucciones de instalación y funcionamiento Wilo TOP-S, TOP-Z Installation and operating instructions Notice de montage et de mise en service Instrucciones de instalación y funcionamiento 2088193-Ed.03/2011-10-DDD Fig. 1a Fig. 1b Fig. 2 Fig. 3 Fig.

More information

MOONRING 1.5 MOONRING 3

MOONRING 1.5 MOONRING 3 INSTALLATION INSTRUCTIONS MOONRING 1.5 MOONRING 3 MR1.5 & MR3 Suspended, Ceiling LED n A 1035 22nd Avenue, Unit 1 Oakland, CA 94606 P 510.489.2530 E TalkToUs@alwusa.com W alwusa.com Safety & Warnings!

More information

Simple comme bonjour!

Simple comme bonjour! SM As easy as 1 2 3! Commercial Vehicle Tech-it SM utilizes on-hand inventory pipes and parts as a fast, easy alternative to waiting for a non-stocking direct-fit part Simple comme bonjour! Le programme

More information

UB-2 2 Universal Button

UB-2 2 Universal Button UB-2 2 Universal Button UB-2/LTUL Universal Button with Latching Timer ADA Compliant For UB-2/LTUL the enclosed timer is to be used and installed per the enclosed LT-1UL installation sheet. For access

More information

ESR-1414 Reissued July 2014 This report is subject to renewal October 1, 2015.

ESR-1414 Reissued July 2014 This report is subject to renewal October 1, 2015. ICC-ES Evaluation Report www.icc-es.org (00) 23-6 (62) 699-03 ESR-11 Reissued July 201 This report is subject to renewal October 1, 201. A Subsidiary of the International Code Council DIVISION: 0 00 00

More information

INSTALLATION INSTRUCTION Magnetic Transformer

INSTALLATION INSTRUCTION Magnetic Transformer IMPORTANT: Read all instructions before installing. Read all instructions before proceeding with the installation. This power supply complies with the requirements of UL1838. This power supply should be

More information

CLUTCH-BRAKES SERIES 5.8 FRENO-EMBRAGUES SERIE 5.8

CLUTCH-BRAKES SERIES 5.8 FRENO-EMBRAGUES SERIE 5.8 CLUTCH-BRAKES SERIES 5.8 FRENO-EMBRAGUES SERIE 5.8 This series corresponds to the latest of the pneumatic clutch-brakes developed by GOIZPER. One of its main characteristics is that it obtains the maximum

More information

Installation Instructions

Installation Instructions at :: rangehoods. com Call 1-800-667-8721 anywhere in the US and Canada - www.rangehoods.com Installation Instructions ZV950 36" Stainless Steel Vent Hood Monogram. We bring good things to life. GE Monogram

More information

Installation Instructions

Installation Instructions Installation Instructions FHEZ10A24 FHEZ17A48 Page 1 of 7 IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 1. Do not mount near gas or electric heaters. 2. Do not attempt to service the battery.

More information

Notice de Montage. Assembly Instructions. Instrucciones de Montaje. Plateforme télescopique circulable pour piscine

Notice de Montage. Assembly Instructions. Instrucciones de Montaje. Plateforme télescopique circulable pour piscine Notice de Montage Plateforme télescopique circulable pour piscine Assembly Instructions walkable telescopic platform for swimming pool Instrucciones de Montaje Plataforma telescópica y transitable para

More information

97Ti, 95Ti, 93T Treadmills Assembly Instructions

97Ti, 95Ti, 93T Treadmills Assembly Instructions 97Ti, 95Ti, 9T Treadmills Assembly Instructions ongratulations... and welcome to the world of The following Parts Identification Listing and the step by step assembly procedures have been assembled to

More information

M Remote Mounting Kit

M Remote Mounting Kit M9208-250 Remote Mounting Kit Installation Instructions M9208-250 Part No. 34-636-2200, Rev. A Issued August 29, 2014 Applications IMPORTANT: Use this M9208-250 Remote Mounting Kit only to control equipment

More information

LZO Series Barrier-Free Water Coolers

LZO Series Barrier-Free Water Coolers LZO8*C, LZO8*CJO, LZO8*CJO INSTALLATION, CARE & USE MANUAL TM LZO Series Barrier-Free Water Coolers 4 9 8 9 4, 8 9 44 Uses HFC-4A refrigerant 4, 4 Sensor Eye Adjustment screw See FIG. 4 See FIG. 0 8,,

More information

LUNERA VERTICAL E26 LED FLOODLIGHT LED Replacement for E26 Medium Base Floodlights Type B Ballast Bypassed

LUNERA VERTICAL E26 LED FLOODLIGHT LED Replacement for E26 Medium Base Floodlights Type B Ballast Bypassed Installation Guide LUNERA VERTICAL E26 LED FLOODLIGHT LED Replacement for E26 Medium Base Floodlights Type B Ballast Bypassed Installation Description The LUNERA VERTICAL E26 LED FLOODLIGHT is a line driven

More information

ZAZERI 48" ZAZERI 60"

ZAZERI 48 ZAZERI 60 Installation alcôve A et installation en coin B Built-in A and corner B installation ZAZERI " ZAZERI 60" ZITTACLEAN " (5 / "~6 /6") (5mm~77mm) 60" (57 7/6"~5 5/" ) (59mm~9mm) "(9 /"~0 /") (75mm~77mm )

More information

Stealth Exhaust 2.0 & Heat Shield

Stealth Exhaust 2.0 & Heat Shield 53570 - Stealth Exhaust 2.0 & Heat Shield 18 2 1 15 9 8 7 19 20 21 16 6 10 17 5 14 4 3 13 12 11 Safety Considerations: 1. Wear gloves during installations and be careful when handling the metal pieces

More information

,000 psi Minimum Yield Strength. 70,000 psi Minimum Tensile Strength

,000 psi Minimum Yield Strength. 70,000 psi Minimum Tensile Strength Commercial Bins/Silos Total Value. Total Systems. Strongest & Heaviest Gauge Tanks in the Industry. A world leader in steel corrugated storage bin manufacturing, GSI offers the strongest and heaviest gauge

More information

Bridge Overhang Brackets

Bridge Overhang Brackets Bridge C49, C49D, C49S and C49JR Bridge Dayton Superior offers the bridge contractor four different Horizontal Length versions of the C49 Bridge Bracket, which allows for maximum adjustability to meet

More information

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTION SAFETY INSTRUCTION IMPORTANT: NEVER attempt any work without shutting off the electricity. Read all instructions before installing. System is intended for installation by a qualified electrician in accordance

More information

INSTALLATION INSTRUCTIONS MOONRING 1 LP1/MR1

INSTALLATION INSTRUCTIONS MOONRING 1 LP1/MR1 INSTALLATION INSTRUCTIONS MOONRING 1 LP1/MR1 Suspended, Ceiling LED n A 1035 22nd Avenue, Unit 1 Oakland, CA 94606 P 510.489.2530 E TalkToUs@alwusa.com W alwusa.com Safety & Warnings! 1. Read all instructions.

More information

229 B-Line series Pipe Hangers & Supports

229 B-Line series Pipe Hangers & Supports accessories offered in this section are designed to reduce installation time. wide range of types and sizes are available for various applications. Materials For maximum loading design, Carbon Steel, Forged

More information

VersaWall SlimLine 1750

VersaWall SlimLine 1750 Index Stick built curtain wall 1 3/4"(44.5mm) profile Mur rideau avec profilé de 1 3/4"(44.5mm) Capped Couvercles à enclenchement Primary components - back sections Composantes principales - traverses

More information

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTION Volta 4.5 - Downlight Round SAFETY INSTRUCTION IMPORTANT: NEVER attempt any work without shutting off the electricity. Read all instructions before installing. System is intended for installation by a

More information

RECOMMENDED TOOLS AND CHECKERS

RECOMMENDED TOOLS AND CHECKERS RECOMMENDED TOOLS AND CHECKERS Page RECOMMENDED TOOLS AND CHECKERS........... 2 4 : An impact wrench can be used with tools with this mark. As tools without this mark are meant to be operated manually,

More information

2.0E ES LVL U.S. Design Manual

2.0E ES LVL U.S. Design Manual I N T E R N A T I O N A L B E A M S 2.0E ES LVL U.S. Design Manual August 2013 2 INTERNATIONAL BEAMS, INC. Our Company At International Beams, Inc. we take pride in providing our customers with premium

More information

FLATBED CARGO CONTROL PRODUCTS

FLATBED CARGO CONTROL PRODUCTS 437 STANDARD WINCH FLATBED CARGO CONTROL PRODUCTS LOW-PROFILE WINCH PORTABLE WINCH PORTABLE WINCH For Weld-on Bottom Mounting Part No. 1010102 STANDARD SLIDING WINCH For Weld-On Side Mounting Part No.

More information

GP Lam LVL. Grade Thickness Depth , 9 1 4, 9 1 2, , , 14, 16, 18, 24 (20 and 22 by special order) 2.

GP Lam LVL. Grade Thickness Depth , 9 1 4, 9 1 2, , , 14, 16, 18, 24 (20 and 22 by special order) 2. GP Lam LVL GP Lam LVL Introduction.....................32 Bearing Details...................34 Handling and Installation..........35 Floor Beams.....................35 Window, Patio Door and Garage Door

More information

Installation Instructions

Installation Instructions Installation Instructions If you have questions, call 800.GE.CARES or visit our website at: www.monogram.com ZV950 36" Stainless Steel Vent Hood Safety Information BEFORE YOU BEGIN Read these instructions

More information

Fitting Instructions for SRG0034 Radiator Guard Radiator Guard KAWASAKI VERSYS

Fitting Instructions for SRG0034 Radiator Guard Radiator Guard KAWASAKI VERSYS Fitting Instructions for SRG0034 Radiator Guard Radiator Guard KAWASAKI VERSYS 650 2015- In This Kit There Should Be 1x Radiator Guard. 1x Spacer. 1 x M6 Bolt. 1x M6 Nut and Washer. 6 x Cable/Zip Ties.

More information

SECTION PIPE HANGERS AND SUPPORTS

SECTION PIPE HANGERS AND SUPPORTS Part I - GENERAL 1.01 SECTION INCLUDES A. The work covered under this section consists of the furnishing of all necessary labor, supervision, materials, equipment, and services to completely execute the

More information

Diagnostic Test Kit Series P Series WARNING. for Polaris Robotic Cleaners

Diagnostic Test Kit Series P Series WARNING. for Polaris Robotic Cleaners Diagnostic Test Kit for Polaris Robotic Cleaners 93 94 95 Series P825 91 Series WARNING H0510700 Rev A The Diagnostic Box and included test cables are to be used solely for diagnosing Polaris Robotic Cleaners.

More information

Brighter lights, Softer sounds.

Brighter lights, Softer sounds. Tone 29X Brighter lights, Softer sounds. cycle + tone Tone is an add-on acoustic accessory conceived for our Cycle luminaire. It absorbs reverberated noise and helps reduce the echo of background sounds

More information

Installation Instructions

Installation Instructions PART NUMBER: CPLPCONV007A00 60,000---130,000 BTU/HR 2TO5TONS SMALL PACKAGED PRODUCTS GAS HEATING/ELECTRIC COOLING UNITS HIGH ALTITUDE ONLY 2001---6000 FT PROPANE CONVERSION KIT Installation Instructions

More information

Cable Cubby 1200 and 1400 Installation Guide

Cable Cubby 1200 and 1400 Installation Guide e NT: R.com for thtion O P IM tron talla w.ex uide, ins ations. o ww Go t te user g specific nd ple com ctions, a u instr 00 and 400 Installation Guide This guide provides instructions for an experienced

More information

Quality by Design CAPACITIES FROM 75,000 TO OVER 750,000 BUSHELS VARIETY OF PEAK LOAD RATINGS LARGE ROOF DECKS

Quality by Design CAPACITIES FROM 75,000 TO OVER 750,000 BUSHELS VARIETY OF PEAK LOAD RATINGS LARGE ROOF DECKS Quality by Design CAPACITIES FROM 75,000 TO OVER 750,000 BUSHELS VARIETY OF PEAK LOAD RATINGS LARGE ROOF DECKS For nearly 80 years Behlen Mfg. Co. has focused on meeting customer needs. This is done with

More information

INSTALLATION INSTRUCTIONS LIGHTPLANE 3.5. LP3.5 Suspended LED. A nd Avenue, Unit 1. CA P E W alwusa.

INSTALLATION INSTRUCTIONS LIGHTPLANE 3.5. LP3.5 Suspended LED. A nd Avenue, Unit 1. CA P E W alwusa. Oakland, INSTALLATION INSTRUCTIONS LIGHTPLANE 3.5 LP3.5 Suspended LED A 1035 22nd Avenue, Unit 1 n CA 94606 P 510.489.2530 E TalkToUs@alwusa.com W alwusa.com Safety & Warnings! 1. Read all instructions.

More information

LVL User s Guide. Technical Data for LVL Headers, Beams, Column Applications for Residential Floor and Roof Systems

LVL User s Guide. Technical Data for LVL Headers, Beams, Column Applications for Residential Floor and Roof Systems LVL User s Guide Technical Data for LVL Headers, Beams, Column Applications for Residential Floor and Roof Systems U N I T E D S T A T E S V E R S I O N Quality Products Committed Service O U R H I S TO

More information

Lumination TM LED Luminaire RC/LRC/RX/LRX Series - New Construction Frame

Lumination TM LED Luminaire RC/LRC/RX/LRX Series - New Construction Frame Installation Guide Lumination TM LED Luminaire RC/LRC/RX/LRX Series - New Construction Frame BEFORE YOU BEGIN Read these instructions completely and carefully. RISK OF ELECTRIC SHOCK Turn power off before

More information

4.4 / MECANISMOS ELEVABLES Y ABATIBLES. Gas stay lift MINI UP / / Compás alzar gas MINI UP. Insert door/ Puerta interior

4.4 / MECANISMOS ELEVABLES Y ABATIBLES. Gas stay lift MINI UP / / Compás alzar gas MINI UP. Insert door/ Puerta interior Gas stay lift MOVE UP / / Compás alzar gas MOVE UP N 1 1 1 1 60 N steel/acero white/blanco 80 N steel/acero white/blanco 100 N steel/acero white/blanco 120 N steel/acero white/blanco 481.150.504 1 60 N

More information

Cable Cubby 500 and 700 Installation Guide

Cable Cubby 500 and 700 Installation Guide e NT: R.com for thtion O P IM tron talla w.ex uide, ins ations. o ww Go t te user g specific nd ple com ctions, a u instr 500 and 700 Installation Guide This guide provides instructions for an experienced

More information

R4040/R4040S FIGURE A / FIGURA A

R4040/R4040S FIGURE A / FIGURA A R00/R00S FIGURE A / FIGURA A 0 0 0 0 0 0 0 0 R00/R00S FIGURE A KEY P/N DESCRIPTION QTY KEY P/N DESCRIPTION QTY KEY P/N DESCRIPTION QTY 0000 Screw (M)... 0000 Splash Guard... 0000 Outer Blade Guard... 0000

More information

INSTALLATION INSTRUCTION Oculux 3.5" Architectural Downlight R3CRN-11, R3CSN-11

INSTALLATION INSTRUCTION Oculux 3.5 Architectural Downlight R3CRN-11, R3CSN-11 . INSTALLATION INSTRUCTION SAFETY INSTRUCTION IMPORTANT: NEVER attempt any work without shutting off the electricity. Read all instructions before installing. System is intended for installation by a qualified

More information

Installation and Maintenance Instructions

Installation and Maintenance Instructions Installation and Maintenance Instructions Limited One Year Warranty T&S warrants to the original purchaser (other than for purposes of resale) that such product is free from defects in material and workmanship

More information

MODEL N COMPLETE BASKETBALL SYSTEM OWNER S MANUAL COPY OWNER S MANUAL. Keep this Product ID Number and use when contacting Customer Service:

MODEL N COMPLETE BASKETBALL SYSTEM OWNER S MANUAL COPY OWNER S MANUAL. Keep this Product ID Number and use when contacting Customer Service: MODEL N 90136 COMPLETE BASKETBALL SYSTEM OWNER S MANUAL OWNER S MANUAL COPY Keep this Product ID Number and use when contacting Customer Service: REGISTER YOUR LIFETIME PRODUCT TODAY! There are benefits

More information

GP Lam LVL. Grade Thickness Depth , , , , , 149, 169, 189, 249 (209and 229 by special order) 2.

GP Lam LVL. Grade Thickness Depth , , , , , 149, 169, 189, 249 (209and 229 by special order) 2. GP Lam LVL Grade Thickness Depth 2.0E 1 3 49, 3 1 29 7 1 49, 9 1 49, 9 1 29, 11 1 49, 11 7 89, 149, 169, 189, 249 (209and 229 by special order) 1.5E 1 3 49 7 1 49, 9 1 49, 9 1 29, 11 1 49, 11 7 89, 149,

More information

Lifting height 5.5" - 72" with adapters " Height overall 165" Width between columns 122" Drive through 109" Width overall 151.

Lifting height 5.5 - 72 with adapters  Height overall 165 Width between columns 122 Drive through 109 Width overall 151. Model Number TP12KC-D Capacity 12,000 lbs. Lifting height 5.5" - 72" with adapters 79.625" Height overall 165" Width between columns 122" Drive through 109" Width overall 151.125" Arm extension 37.5" -

More information

Commercial Bins/Silos

Commercial Bins/Silos Commercial Bins/Silos Strongest & Heaviest Gauge Tanks in the Industry. A world leader in steel corrugated storage bin manufacturing, Grain Systems offers the strongest and heaviest gauge storage tanks

More information

LED VaporProof Fixture

LED VaporProof Fixture ASD LED VaporProof Fixture is a modern lighting fixture widely used in different environments. Besides contemporary design, it has a row of features that makes it a perfect choice for everyone. Its main

More information

42" 4" 42 3/4" 21" 44" 10" 44" 34"

42 4 42 3/4 21 44 10 44 34 Q99-E Toyota Corolla 4dr 2003-2008 Front: Q99-E Rear: Q31-A 67,81,109,114,144,191,197 39 5/8" 5" 39 5/8" 32" Highlander/ Highlander Hybrid 5dr 2008-2013 Front: Q99-E Rear: Q99-E 54,67,69,81,109 47" 9"

More information

Assembly Instructions Instrucciones para ensamblar Instructions de montage. Montageanleitungen Montage-instructies

Assembly Instructions Instrucciones para ensamblar Instructions de montage. Montageanleitungen Montage-instructies ssembly Instructions Instrucciones para ensamblar Instructions de montage Montageanleitungen Montage-instructies 3 1 2 4 5 x 2 6 8 7 10 12 x 2 9 11 14 18 17 15 19 16 x 2 Parts and Hardware Partes y Piezas

More information

UNE ISO RNL

UNE ISO RNL SERIE RNL UNE 166.002 ISO 14001 RNL 1063 Agrupadas según eje Grouped according to the shaft form RNL 1450 R.P.M..M. Altura () Head Altura () Head Caudal (Q) Capacity RNL 2900 R.P.M..M. Caudal (Q) Capacity

More information

ESR-2408 Reissued August 2014 This report is subject to renewal August 2015.

ESR-2408 Reissued August 2014 This report is subject to renewal August 2015. ICC-ES Evaluation Report ESR-2408 Reissued August 2014 This report is subject to renewal August 2015. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council DIVISION:

More information

LZOTL Series Versatile Bi-Level Water Coolers

LZOTL Series Versatile Bi-Level Water Coolers INSTALLATION, CARE & USE MANUAL LZOTL Series Versatile Bi-Level Water Coolers Versatile Cooler Model LZOTL8 configuration as shipped Versatile Cooler Model LZOTL8 alternate installation Page Note: Danger!

More information

GP Lam LVL. (20!and 22! by special order) 13 4! 31 2! 1.5E. Lengths: up to 60 feet. Referenced dimensions are nominal and used for design purposes.

GP Lam LVL. (20!and 22! by special order) 13 4! 31 2! 1.5E. Lengths: up to 60 feet. Referenced dimensions are nominal and used for design purposes. GP Lam LVL Grade 2.0E 1.5E Thickness Depth 13 4!, 31 2! 7 4!, 9 4!, 9 2!, 11 4!, 117 8!, 14!, 16!, 18!, 24! (20!and 22! by special order) 13 4! 7 1 4!, 9 1 4!, 9 1 2!, 111 4!, 117 8!, 14!, 16! 31 2! 45

More information

16V Cordless drill / driver PAGe 6 eng 16 Voltios taladro inalambrico PAGe 11 esp PerCeuse / tournevis à 16V PAGe 17 Fre rk2600k2

16V Cordless drill / driver PAGe 6 eng 16 Voltios taladro inalambrico PAGe 11 esp PerCeuse / tournevis à 16V PAGe 17 Fre rk2600k2 PAGe 6 ENG 16 Voltios Taladro Inalambrico PAGe 11 ESP Perceuse / Tournevis à 16V PAGE 17 FRE RK2600K2 Thank you for purchasing a ROCKWELL power tool. We are confident that you will appreciate the quality

More information

Parent s Guide. This guide contains important information. Please keep it for future reference US

Parent s Guide. This guide contains important information. Please keep it for future reference US Parent s Guide This guide contains important information. Please keep it for future reference. 91-003324-000 US INTRODUCTION The Stack & Tumble Elephant TM provides a silly twist on the classic ring stacker.

More information

Your Powersport Lighting Source! Powersport Lighting 2018 Catalog

Your Powersport Lighting Source! Powersport Lighting 2018 Catalog Your Powersport Lighting Source! LED Power Bulbs Index Street LED Headlight Power Bulbs Off-Road LED Headlight Power Bulbs LED Power Bulbs... page 3 Big Twins Lighting... page 4 Motorcycles Lighting...

More information

COMMISSION INTERNATIONALE DE KARTING - FIA

COMMISSION INTERNATIONALE DE KARTING - FIA FICHE D HOMOLOGATION HOMOLOGATION FORM Homologation N COMMISSION INTERNATIONALE DE KARTING - FIA MOTEUR / ENGINE OK Constructeur Manufacturer TM RACING S.P.A. Marque Make TM RACING Modèle Model S-SENIOR

More information

MINI. Technical Data for. PWI Joists, PWLVL Headers, Beams, and Dimension

MINI. Technical Data for. PWI Joists, PWLVL Headers, Beams, and Dimension E N G I N E E R E D W O O D MINI Technical Data for PWI s, PWLVL Headers, Beams, and Dimension P R O D U C T S S A F E T Y, H A N D L I N G & P E R F O R M A N C E 2 SAFETY & CONSTRUCTION PRECAUTIONS INSTALLATION

More information

The following excerpt are pages from the North American Product Technical Guide, Volume 1: Direct Fastening, Edition 15.

The following excerpt are pages from the North American Product Technical Guide, Volume 1: Direct Fastening, Edition 15. The following excerpt are pages from the North American Product Technical Guide, Volume 1: Direct Fastening, Edition 15. Please refer to the publication in its entirety for complete details on this product

More information

LZO Series Sensor-Operated Water Coolers

LZO Series Sensor-Operated Water Coolers LZO*G LZO*G LZO*G LZOD*D INSTALLATION, CARE & USE MANUAL LZO Series Sensor-Operated Water Coolers Model LZOL Page 00000094 (Rev. B - /) LZO*G LZO*G LZO*G LZOD*D Note: Danger! Electrical shock hazard. Disconnect

More information