1 Oakland, INSTALLATION INSTRUCTIONS LIGHTPLANE 3.5 LP3.5 Suspended LED A nd Avenue, Unit 1 n CA P E TalkToUs@alwusa.com W alwusa.com

2 Safety & Warnings! 1. Read all instructions. 2. Install in accordance with national and local electrical code regulations. 3. This product is intended to be installed and serviced by a qualified, licensed electrician. 4. Turn off electrical power before installing or servicing fixture in any way. 5. Do not install in wet locations. For dry and damp use only. 6. Turn off electrical power before installing or servicing fixture in any way. 7. To reduce the risk of fire and overheating, make sure all connections are tight. 8. This product is suitable for continuous row mounting. Attention! 1. Lisez toutes les instructions. 2. Installez conformément à la réglementation du code électrique national et local. 3. Ce produit est destiné à être installé et entretenu par un électricien agréé qualifié. 4. Coupez l alimentation électrique avant d installer ou de réparer le luminaire de quelque manière que ce soit. 5. Ne pas installer à l extérieur ou dans des endroits humides. Pour une utilisation en intérieur et sec seulement. 6. Coupez l alimentation électrique avant de évoluer le système d éclairage en aucune façon. 7. Pour réduire le risque d incendie et de surchauffe, assurez-vous que toutes les connexions sont bien serrées. 8. Ce produit convient au montage en ligne continue. SHOCK HAZARD! May result in serious injury or death. Turn power OFF at circuit breaker prior to installation or servicing. LP3.5 Suspended Installation Guide 2 of IG A.0

3 Table of Contents Luminaire Overview 4 Diagrams 4 Components 4 Parts (by others) 4 Tools Required 4 Quick Specs 4 Installation 5 Prepare Ceiling 5 Standard Suspension 5 Connecting Multiple Sections 7 Troubleshooting 10 Wiring Diagrams 11 LP3.5 Suspended Installation Guide 3 of IG A.0

4 LUMINAIRE OVERVIEW To Building Power Ceiling Fitting / Suspension Bullet J-Box Canopy Power Cord Suspension Cables Cable Gripper Fixture Body Integrated LED Driver STANDARD SUSPENSION COMPONENTS Canopy Assembly Suspension Bullet Suspension Cable Ceiling Fitting Parts (by others) 4 Square or Octagonal Junction Box Wood Screws, #10, 1.5 long Tools Required Drill #2 phillips bit Wire strippers 1/8 Hex Key (for Joining) 5mm Hex Key (for Joining) Quick Specs Input Voltage / Frequency: See product label Rated Power: See product drawing Ambient Temperature: F ( C) Environment: Dry and damp locations LP3.5 Suspended Installation Guide 4 of IG A.0

5 Installation: Prepare Ceiling Installation: Standard Suspension A C L SAMPLE DRAWING 1 See Final/Record Drawings for Mounting Locations See final/record drawings for mounting locations. Install framing CHECK FOR or strut channels with consideration ELECTRICAL for WIRING: alignment of wiring and suspension mounting locations. MUST 3A Install Ceiling Fitting - Framing Ceiling Fittings may be installed directly into framing with appropriate hardware. A T C L SAMPLE DRAWING 2 Install Canopy J-Box Install 4 square or octagonal Canopy J-Box (sold separately) at power feed location per final/record drawing. CHECK FOR ELECTRICAL WIRING: 3B Install Ceiling Fitting - Toggle Bolts Ceiling Fittings may also be mounted using toggle bolts. MUST T! SHOCK HAZARD! May result in serious injury or death. Turn power OFF at circuit breaker prior to installation or servicing. DO NOT PINCH OR PUT EXCESSIVE TENSION ON WIRES while joining sections or reattaching heatsink. 3C Install Ceiling Fitting - 1/4-20 Threaded Rods Ceiling Fittings may also be mounted on 1/4-20 Threaded Rods. LP3.5 Suspended Installation Guide 5 of IG A.0

6 Installation: Standard Suspension (Cont.) 4 Route Suspension Cable and Attach to Ceiling Route Suspension Cable through Suspension Bullet. Ball end should sit in Suspension Bullet. Screw Suspension Bullet to Ceiling Fitting. 7 Raise Fixture to Suspension Cables Raise fixture to Suspension Cables, and attach fixture by inserting Suspension Cable through Cable Grippers. 6" 5 Cut Suspension Cables to Desired Length 8 Adjust Suspension Cable Length Use wire snips or shears to cut Suspension Cables to desired length. Keep an extra 6 inches of cable for adjustments. Adjust fixture until it is level and at desired height. Depress top of Cable Gripper to lower fixture. Keep fixture supported while lowering. Cut excess cable. SHOCK HAZARD! May result in serious injury or death. Turn power OFF at circuit breaker prior to installation or servicing. 6 Connecting Multiple Sections (If Necessary) Please see steps 12 through 25 for directions on connecting multiple sections. 9 Connect High Voltage Wiring Bring wiring and canopy assembly to J-box. Refer to page 11 and final/record drawing to make wiring connections. CAUTION: High Voltage Wire Ensure Power is OFF prior to connecting wiring. LP3.5 Suspended Installation Guide 6 of IG A.0

7 Installation: Standard Suspension (Cont.)! DO NOT PINCH OR PUT EXCESSIVE TENSION ON WIRES while installing canopy. Installation: Connecting Multiple Sections 10A Mount Canopy Bracket to J-Box & Secure Canopy Mount Canopy Bracket to J-Box using provided screws, then secure Canopy over J-Box with finial. CAUTION: Do not pinch wire connections. 12 Remove Lens Carefully remove lens using suction cup or similar.! DO NOT PINCH OR PUT EXCESSIVE TENSION ON WIRES while installing canopy. 10B Combo Canopy Installation Mount Canopy Bracket to J-Box using provided screws, then secure Canopy over J-Box with finial. Attach bullet (with cable) to canopy. CAUTION: Do not pinch wire connections. 13 Remove Heatsink/Reflector Screws Remove heatsink/reflector screws that attach to housing. Set aside. 11 Turn Power On Turn breaker ON and check if fixture operates as intended and that there are no loose connections. 14 Remove Heatsink/Reflector Remove heatsink/reflector and hang over side of fixture. CAUTION: Do not apply excessive tension to wires! LP3.5 Suspended Installation Guide 7 of IG A.0

8 Installation: Connecting Multiple Sections (Cont.) 15 Align and Join Sections Together Join sections together, as shown, ensuring correct alignment. See final/record drawing for more details. CAUTION: Do not pinch wires while joining! 18 Tighten Set Screws on Outer Corner Tighten set screws to secure outer corner bracket to joined section using a 1/8 hex key. Ensure each section is properly aligned and that there are no gaps between sections. 16 Tighten Joiner Screws Tighten joiner screws, as shown, using a 5mm hex key. Ensure each section is properly aligned, and that there are no gaps between sections. 19 Tighten Joiner Screws on Inner Corner Tighten joiner screws, as shown, using a 5mm hex key. Ensure each section is properly aligned, and that there are no gaps between sections. 17 Mitered Corners: Join Sections Join sections together, as shown, ensuring correct alignment. See final/record drawing for more details. CAUTION: Do not pinch wires while joining! 20 Connect Wiring Between Sections Connect wiring quick-connects between sections. Match each color, as shown. NOTE: Color combinations may vary. LP3.5 Suspended Installation Guide 8 of IG A.0

9 Installation: Connecting Multiple Sections (Cont.)! SHOCK HAZARD! May result in serious injury or death. Turn power OFF at circuit breaker prior to installation or servicing. DO NOT PINCH OR PUT EXCESSIVE TENSION ON WIRES while joining sections or reattaching heatsink. 23 Install Diffuser Shim Install Diffuser Shim at each joined location to prevent light leak between lens sections. Re-install at endcap locations, as necessary. 21 Re-install Heatsink/Reflector Re-install each heatsink/reflector section. CAUTION: Do not pinch wires while reattaching! 24 Re-install Lens Carefully re-install lens, ensuring lens sits properly within Lens Clips. 22 Re-install Heatsink/Reflector Screws Re-install heatsink/reflector screws to attach back to housing. 25 Ensure Lens Sits Properly Between Lens Clips Ensure the lens is properly installed between the Lens Clips. LP3.5 Suspended Installation Guide 9 of IG A.0

10 Troubleshooting Only a certified electrician can service and troubleshoot product field issues. Always turn main power off before servicing fixture. Full Fixture does not illuminate Ensure all wire connections are made. Ensure fixture is wired correctly and power is on. Check that circuit breaker is on and not off or tripped. LED driver may be defective. Fixture section(s) do not illuminate Possible loose low voltage DC + or - connection between LED boards or from LED driver to LED boards. Some fixtures contain multiple LED drivers. In this case, it s possible one of the drivers is defective, which will cause the LED connected to the driver not to illuminate. Call tech support. Full fixture is flickering 0-10V, DMX, and DALI Dimming Models: Ensure polarity is correct for DATA + and - connections. Swapping DATA + and - connections can cause flickering. TRIAC Dimming Models: Ensure a compatible TRIAC Forward Phase dimmer is connected to fixture. Call tech support for further information. Possible loose DATA + and - connections from fixture to 0-10V, DMX, or DALI control. Possible loose low voltage DC + or - connection from driver to LED. Call customer support. Fixture section(s) are flickering Possible loose low voltage DC + or - connection between LED boards. Fixture does not dim 0-10V, DMX, and DALI Dimming Models: Ensure polarity is correct for DATA + and - connections. Swapping DATA + and - connections can cause flickering. TEST. TRIAC Dimming Models: Ensure a compatible TRIAC Forward Phase dimmer is connected to fixture. Call tech support for further information. Possible loose DATA + and - connections from fixture to 0-10V, DMX, or DALI control. LP3.5 Suspended Installation Guide 10 of IG A.0

11 Wiring Diagrams Traditional On/Off Canopy/Power Feed L N AC 50/60Hz Line Voltage (Hot) Line Voltage (Neutral) Ground White Green 0-10V Dimming Canopy/Power Feed L N AC 50/60Hz Line Voltage (Hot) Line Voltage (Neutral) Ground White Green DIM- DIM+ 0-10VDC (Dim-) 0-10VDC (Dim+) Grey Purple DMX Canopy/Power Feed AC 50/60Hz L N Line Voltage (Hot) Line Voltage (Neutral) Ground White Green DMX In Shield DMX in - DMX in + DMX in shield DMX in - DMX in + Clear Red DMX Out Shield DMX out - DMX out + DMX out shield DMX out - DMX out + Clear White LP3.5 Suspended Installation Guide 11 of IG A.0

12 Wiring Diagrams (Cont.) DALI Canopy/Power Feed L Line Voltage (Hot) N AC 50/60Hz Line Voltage (Neutral) Ground White Green DATA + Data + Purple DATA - Data - Grey Canopy/Power Feed Lutron LDE L Line Voltage (Hot) N AC 50/60Hz Line Voltage (Neutral) Ground White Green E1 E1 Purple E2 E2 Grey LP3.5 Suspended Installation Guide 12 of IG A.0

INSTALLATION INSTRUCTIONS MOONRING 1 LP1/MR1

INSTALLATION INSTRUCTIONS MOONRING 1 LP1/MR1 INSTALLATION INSTRUCTIONS MOONRING 1 LP1/MR1 Suspended, Ceiling LED n A 1035 22nd Avenue, Unit 1 Oakland, CA 94606 P 510.489.2530 E TalkToUs@alwusa.com W alwusa.com Safety & Warnings! 1. Read all instructions.

More information

MOONRING 1.5 MOONRING 3

MOONRING 1.5 MOONRING 3 INSTALLATION INSTRUCTIONS MOONRING 1.5 MOONRING 3 MR1.5 & MR3 Suspended, Ceiling LED n A 1035 22nd Avenue, Unit 1 Oakland, CA 94606 P 510.489.2530 E TalkToUs@alwusa.com W alwusa.com Safety & Warnings!

More information

INSTALLATION INSTRUCTIONS SUPERPLANE 2.5. Suspended. A nd Avenue, Unit 1 Oakland, CA P E W alwusa.

INSTALLATION INSTRUCTIONS SUPERPLANE 2.5. Suspended. A nd Avenue, Unit 1 Oakland, CA P E W alwusa. INSTALLATION INSTRUCTIONS SUPERPLANE 2.5 Suspended A 1035 22nd Avenue, Unit 1 Oakland, CA 94606 P 510.489.2530 E TalkToUs@alwusa.com W alwusa.com SP2.5S - Safety & Warnings! 1. Read all instructions. 2.

More information

Lumination TM LED Luminaires Suspended LED Fixture (Series EP14)

Lumination TM LED Luminaires Suspended LED Fixture (Series EP14) GE Lighting Solutions Installation Guide Lumination TM LED Luminaires Suspended LED Fixture (Series EP14) Features Long life (50,000 hour rated life) 5 year warranty IP30 Dry location rated BEFORE YOU

More information

READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION

READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION UR Series LED Upgrade Kit Includes: 24" Linear Option IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following: READ AND FOLLOW ALL

More information

INSTALLATION INSTRUCTION Aether 2 Shallow Recessed Housing

INSTALLATION INSTRUCTION Aether 2 Shallow Recessed Housing SAFETY INSTRUCTIONS IMPORTANT: NEVER attempt any work without shutting off the electricity. Read all instructions before installing. System is intended for installation by a qualified electrician in accordance

More information

INSTALLATION INSTRUCTION Aether 3.5 Color Tunable LED Downlight

INSTALLATION INSTRUCTION Aether 3.5 Color Tunable LED Downlight SAFETY INSTRUCTION IMPORTANT: NEVER attempt any work without shutting off the electricity. Read all instructions before installing. System is intended for installation by a qualified electrician in accordance

More information

INSTALLATION INSTRUCTION Oculux 3.5" Architectural Downlight R3CRN-11, R3CSN-11

INSTALLATION INSTRUCTION Oculux 3.5 Architectural Downlight R3CRN-11, R3CSN-11 . INSTALLATION INSTRUCTION SAFETY INSTRUCTION IMPORTANT: NEVER attempt any work without shutting off the electricity. Read all instructions before installing. System is intended for installation by a qualified

More information

IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following:

IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following: ZR-RK Series LED Retrofit Troffer Kit Includes: ZR22RK and ZR24RK Standard and Emergency Luminaires IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed

More information

Albeo TM LED Luminaire Heavy Industrial High Bay Lighting (ABR1-Series)

Albeo TM LED Luminaire Heavy Industrial High Bay Lighting (ABR1-Series) GE Lighting Installation Guide Albeo TM LED Luminaire Heavy Industrial High Bay Lighting (ABR1-Series) Features UL 1598 Suitable for Wet Locations IP66 Rated Ingress Protection BEFORE YOU BEGIN Read these

More information

INSTALLATION INSTRUCTIONS LED RETROFIT ASSEMBLY (LRA) Rev F

INSTALLATION INSTRUCTIONS LED RETROFIT ASSEMBLY (LRA) Rev F SAFETY S IMPORTANT SAFETY INFORMATION SUITABLE FOR DRY OR DAMP LOCATIONS. NOT FOR USE WITH PHASE CUT DIMMERS. Risk of shock. Disconnect power before installation. DANGER CONVIENT AUX EMPLACEMENTS HUMIDES.

More information

Lumination TM LED Luminaires LAL Series - Continuous Run Option

Lumination TM LED Luminaires LAL Series - Continuous Run Option GE Lighting Installation Guide Lumination TM LED Luminaires LAL Series - Continuous Run Option BEFORE YOU BEGIN Read these instructions completely and carefully. WARNING/AVERTISSEMENT RISK OF ELECTRIC

More information

EMERY SKY SUSPENDED LED LUMINAIRE

EMERY SKY SUSPENDED LED LUMINAIRE EMERY SKY SUSPENDED LED LUMINAIRE IP20 DRY LOCATION 120V- 277V AC SAFETY & WARNINGS 1. READ AND FOLLOW ALL SAFETY INSTRUCTIONS 2. Install in accordance with national and local electrical code regulations.

More information

INSTALLATION INSTRUCTIONS LED Canopy Retrofit Kit

INSTALLATION INSTRUCTIONS LED Canopy Retrofit Kit INSTALLATION INSTRUCTIONS LED Canopy Retrofit Kit TRMUNV065ECxyyZ TRAUNV065ECxyyZ Installation Instructions subject to change without notice. Page 1 of 8 1.0 INSTALLATION WARNINGS 1. 2. 3. 4. 5. 6. "THIS

More information

OSQ Series IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. LED Area Light TO INSTALL:

OSQ Series IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. LED Area Light TO INSTALL: OSQ Series LED Area Light Direct Pole Mount IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following: READ AND FOLLOW ALL SAFETY

More information

Lumination TM LED Luminaire RC/LRC/RX/LRX Series - New Construction Frame

Lumination TM LED Luminaire RC/LRC/RX/LRX Series - New Construction Frame Installation Guide Lumination TM LED Luminaire RC/LRC/RX/LRX Series - New Construction Frame BEFORE YOU BEGIN Read these instructions completely and carefully. RISK OF ELECTRIC SHOCK Turn power off before

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INDIGO-CLEAN TECHNOLOGY RETROFIT KIT INSTALLATION INSTRUCTIONS 1 IMPORTANT SAFETY INFORMATION Risk of shock. Disconnect power before installation. DANGER- RISQUE DE CHOC- COUPER L ALIMENTATION AVANT L

More information

GETTING STARTED WITH IN-WALL DIMMER SWITCH

GETTING STARTED WITH IN-WALL DIMMER SWITCH GETTING STARTED WITH IN-WALL DIMMER SWITCH This document is the property of Webee L.L.C. The data contained here, in whole or in part, may not be duplicated, used or disclosed outside the recipient for

More information

Spun Bay Installation Standard Version (non dimmable), Hook Mount

Spun Bay Installation Standard Version (non dimmable), Hook Mount Spun Bay Installation Standard Version (non dimmable), Hook Mount WARNING: Make sure that all power is turned off while installing fixture. Do not turn power on until fixture is completely installed. Turn

More information

LS1 SERIES IMPORTANT: READ ALL INSTRUCTIONS THOROUGHLY AND CAREFULLY PRIOR TO INSTALLATION OF LINEAR SERIES FIXTURES AND RETAIN FOR FUTURE REFERENCE.

LS1 SERIES IMPORTANT: READ ALL INSTRUCTIONS THOROUGHLY AND CAREFULLY PRIOR TO INSTALLATION OF LINEAR SERIES FIXTURES AND RETAIN FOR FUTURE REFERENCE. The LS1 Series of commercial and industrial LED fixtures is designed to be used in utility strip applications using suspension or surface mount installation. The LS1 Series is designed for use in 120 277V,

More information

INSTALLATION INSTRUCTION Bollard Light 12V

INSTALLATION INSTRUCTION Bollard Light 12V Bollard Light 12V 6611/6621/6631/6641/6651 SAFETY INSTRUCTION IMPORTANT: NEVER attempt any work without shutting off the electricity. Read all instructions before installing. System is intended for installation

More information

Wet Rated Batten LED Luminaire

Wet Rated Batten LED Luminaire Installation Guide Wet Rated Batten LED Luminaire LED Lighting System BEFORE YOU BEGIN Read these instructions completely and carefully. WARNING / AVERTISSEMENT RISK OF ELECTRIC SHOCK Turn power off before

More information

Captivate Illuminated Mirror Light

Captivate Illuminated Mirror Light ENGLISH WARNINGS & SAFETY INFORMATION: PLEASE READ CAREFULLY FRANÇAIS MISES EN GARDE ET SÉCURITÉ: SE IL VOUS PLAÎT LIRE ATTENTIVEMENT WARNING: RISK OF FIRE OR ELECTRIC SHOCK. LUMINAIRE WIRING AND ELECTRICAL

More information

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTION Volta 4.5 - Downlight Round SAFETY INSTRUCTION IMPORTANT: NEVER attempt any work without shutting off the electricity. Read all instructions before installing. System is intended for installation by a

More information

Installation Instructions Sero / Qub Pendant RETROFIT CONSTRUCTION- INACCESSIBLE CEILING Mounting Option GP

Installation Instructions Sero / Qub Pendant RETROFIT CONSTRUCTION- INACCESSIBLE CEILING Mounting Option GP WARNINGS: Do not assemble continuous run on the ground and lift into place. Joints will distort and not create a tight fit. Joining hardware will have to be purchased and replaced. Risk of electrical shock

More information

HP-2 / HP-6 Direct Installation Instructions Overview

HP-2 / HP-6 Direct Installation Instructions Overview Overview Helpful Video 0-10V Dimming Step 1 Mounting & Suspension Page 2 Step 2 Identification & Preparation Page 3 Step 3 Mounting to Structure Page 4 NOTE Step 4 Page 5 This installation requires proper

More information

The only lighting product that is designed, approved, and patented to replace the cross members in a suspended grid ceiling system.

The only lighting product that is designed, approved, and patented to replace the cross members in a suspended grid ceiling system. by The only lighting product that is designed, approved, and patented to replace the cross members in a suspended grid ceiling system. JLC-Tech LLC Pembroke, MA - USA 781-826-8162 info@jlc-tech.com www.tbarledsmartlight.com

More information

MAXLITE RKT LED Retrofit Kit

MAXLITE RKT LED Retrofit Kit MAXLITE RKT LED Retrofit Kit Description and Intended Use The RKT LED Retrofit Kit is a high performance LED Fixture upgrade kit designed to replace the original components inside 2 x2 and 2 x4 fluorescent

More information

LAL SERIES LED LUMINAIRE

LAL SERIES LED LUMINAIRE INSTALLATION, OPERATION & MAINTENANCE DATA SHEET LAL SERIES LED LUMINAIRE CAUTION: LAL SERIES LED LUMINAIRE Before installing, make sure you are compliant with area classifications, failure to do so may

More information

MEDIA LED. Pendant Standard Mount Installation ou de montage WARNING:

MEDIA LED. Pendant Standard Mount Installation ou de montage WARNING: MEDIA LED Pendant Standard Mount WARNING: Disconnect main power at the source prior to installation! Thread gripper base onto 1 /4 20 stud, or with #8 screw. Depress gripper nozzle to insert aircraft cable.

More information

Customer service: or Upper mounting ring. Canopy

Customer service: or Upper mounting ring. Canopy Components included: Upper mounting ring Canopy Fixture base Fluorescent - 2 x 42 W 4-pin compact fluorescent lamps required (not included). Lutron recommends GE, Sylvania, or Philips lamps that are certified

More information

Specification Grade Contemporary Wall Mount/Technical Installation Data

Specification Grade Contemporary Wall Mount/Technical Installation Data AVAILABLE CONFIGURATIONS RECESSED MOUNT SURFACE MOUNT MOUNTING REQUIREMENTS A. Recessed Mount: Minimum 4-Gang Box, 1-5/8 in. Deep (72.8 Cubic Inches) with 4-Gang Box Cover (20.3 Cubic Inches) B. Surface

More information

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTION SAFETY INSTRUCTION IMPORTANT: NEVER attempt any work without shutting off the electricity. Read all instructions before installing. System is intended for installation by a qualified electrician in accordance

More information

Elle Surface Mounting Instructions

Elle Surface Mounting Instructions Step 1: Preparation, page 2 Warnings CAUTION risk of fire and this product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation

More information

Tetra minimax. LED Lighting System. BEFORE YOU BEGIN Read these instructions completely and carefully. Installation Guide

Tetra minimax. LED Lighting System. BEFORE YOU BEGIN Read these instructions completely and carefully. Installation Guide Installation Guide Volt Tetra minimax LED Lighting System GEMMRD-W, GEMMGL-W, GEMMBL-W BEFORE YOU BEGIN Read these instructions completely and carefully. WARNING/AVERTISSMENT RISK OF ELECTRIC SHOCK Turn

More information

Elle Surface Mounting Instructions

Elle Surface Mounting Instructions Step 1: Preparation, page 2 Warnings CAUTION risk of fire and this product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation

More information

LUNERA VERTICAL E26 LED FLOODLIGHT LED Replacement for E26 Medium Base Floodlights Type B Ballast Bypassed

LUNERA VERTICAL E26 LED FLOODLIGHT LED Replacement for E26 Medium Base Floodlights Type B Ballast Bypassed Installation Guide LUNERA VERTICAL E26 LED FLOODLIGHT LED Replacement for E26 Medium Base Floodlights Type B Ballast Bypassed Installation Description The LUNERA VERTICAL E26 LED FLOODLIGHT is a line driven

More information

Lumination TM LED Luminaire (IS Series)

Lumination TM LED Luminaire (IS Series) GE Lighting Installation Guide Lumination TM LED Luminaire (IS Series) There are three types of fixtures: Starter (ISSseries) Continuous (ISCseries) Independent (IS1series) Use Starter Kit in general case.

More information

Installation Instructions CRAFT M/L

Installation Instructions CRAFT M/L RISK OF FIRE AND ELECTRICAL SHOCK Contact, improper installation, or improper servicing MAY RESULT IN DEATH OR SERIOUS INJURY! Fixture must be installed by a qualifi ed electrician only. Fixture is intended

More information

Installation Instructions

Installation Instructions Installation Instructions FHEZ10A24 FHEZ17A48 Page 1 of 7 IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 1. Do not mount near gas or electric heaters. 2. Do not attempt to service the battery.

More information

ELV1abbccd-e. Color Temperature: 30 = 3000K White 35 = 3500K White 40 = 4000K White 45 = 4500K White 50 = 5000K White

ELV1abbccd-e. Color Temperature: 30 = 3000K White 35 = 3500K White 40 = 4000K White 45 = 4500K White 50 = 5000K White GE Lighting Immersion TM Elite LED Refrigerated Display Lighting End Mullion Lights for Vertical Cases Installation Guide ELV1abbccd-e Prefix: EL = Elite V = Vertical FD = French Door 1 = Generation Light

More information

960 Montage sur staff préfabriqué Mounting in prefabricated plaster

960 Montage sur staff préfabriqué Mounting in prefabricated plaster 1 Caractéristique Spot encastré orientable type cardan monté sur cadre en staff, pour lampe LED 9,8 Watts - 380 à 40 Lumens, 2700 à 5000 K IRC : 95 lentille 10 à 0. Feature Recessed gimballed low-voltage

More information

WARNING/AVERTISSEMENT. Coupez l alimentation électrique à la boîte de fusibles ou au disjoncteur avant servicing or installing product.

WARNING/AVERTISSEMENT. Coupez l alimentation électrique à la boîte de fusibles ou au disjoncteur avant servicing or installing product. Tetra Contour LS LED Lighting System GEXNLBL-1, GEXNLGL-1, GEXNLRD-1, GEXNL65-1, GEXNL32-1 Installation Guide 24 Volt BEFORE YOU BEGIN Read these instructions completely and carefully. WARNING/AVERTISSEMENT

More information

CES MOUNT SMS MOUNT EAS MOUNT PNS MOUNT LOUVER OPTION 2700K 3000K 3500K 4000K STATIC GREEN STATIC RED STATIC AMBER WHITE (4000K) - 48" FIXTURE

CES MOUNT SMS MOUNT EAS MOUNT PNS MOUNT LOUVER OPTION 2700K 3000K 3500K 4000K STATIC GREEN STATIC RED STATIC AMBER WHITE (4000K) - 48 FIXTURE CES MOUNT SMS MOUNT EAS MOUNT PNS MOUNT LOUVER ITEM LIGHT SOURCE SPECIFICATION 3.5W/FT, 6W/FT, 12W/FT OPTICS COLOR TEMPERATURES 2700K 3000K 3500K 4000K RED GREEN BLUE AMBER CRI 82 PERFORMANCE WHITE (4000K)

More information

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be

More information

INSTALLATION INSTRUCTION Bliss - Vanities & Wall Sconces WS-79622

INSTALLATION INSTRUCTION Bliss - Vanities & Wall Sconces WS-79622 WS-79622 WARNING IMPORTANT: NEVER attempt any work without shutting off the electricity. - Read all instructions before installing. - System is intended for installation by a qualified electrician in accordance

More information

WARNING / AVERTISSEMENT

WARNING / AVERTISSEMENT TM Arize LED Lighting System Lynk & Life Installation Guide BEFORE YOU BEGIN Read these instructions completely and carefully. WARNING / AVERTISSEMENT RISK OF ELECTRIC SHOCK RISQUES DE DÉCHARGES ÉLECTRIQUES

More information

CES MOUNT SMS MOUNT EAS MOUNT PNS MOUNT LOUVER OPTION 2700K 3000K 3500K 4000K STATIC GREEN STATIC RED STATIC AMBER WHITE (4000K) - 48" FIXTURE

CES MOUNT SMS MOUNT EAS MOUNT PNS MOUNT LOUVER OPTION 2700K 3000K 3500K 4000K STATIC GREEN STATIC RED STATIC AMBER WHITE (4000K) - 48 FIXTURE CES MOUNT SMS MOUNT EAS MOUNT PNS MOUNT LOUVER ITEM LIGHT SOURCE SPECIFICATION 3.5W/FT, 6W/FT, 12W/FT OPTICS COLOR TEMPERATURES 2700K 3000K 3500K 4000K RED GREEN BLUE AMBER CRI 82 PERFORMANCE WHITE (4000K)

More information

Horticulture Batten LED Luminaire

Horticulture Batten LED Luminaire GE Lighting Installation Guide Horticulture Batten LED Luminaire LED Lighting System BEFORE YOU BEGIN Read these instructions completely and carefully. WARNING/AVERTISSEMENT RISK OF ELECTRIC SHOCK Turn

More information

I. Pendant Mount Installation

I. Pendant Mount Installation LED HIGH BAY MAX Luminaires for High Bay Applications HBM SERIES IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following: 1 THIS

More information

Have a Bright Day! Nicholas Harmon President, Verilux, Inc.

Have a Bright Day! Nicholas Harmon President, Verilux, Inc. VF02 Dear Customer, Thank you for purchasing the Verilux EasyFlex Deluxe Natural Spectrum Floor Lamp. You have received a quality product, backed by a one year limited warranty. As a Verilux customer,

More information

ALL700/ALL700-CM INSTALLATION INSTRUCTIONS

ALL700/ALL700-CM INSTALLATION INSTRUCTIONS ALL700/ALL700-CM INSTALLATION INSTRUCTIONS Aladdin Light Lift, Inc. (256) 429-9700 61 Shields Road (877) 287-4601 Huntsville, AL 35811 www.aladdinlightlift.com Patent #5105349 WARNING: Disconnect power

More information

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48. support@i2systems.com www.i2systems.com Electrical Specifications PARAMETER Input Power VALUE 8 Watts* / Ft Input Voltage 120-277V AC, 50/60 Hz Max. Fixture Run Length LED Color (CCT) 8 Watts: 120VAC:

More information

INSTALLATION INSTRUCTION Vanities & Wall Sconce WS-85618

INSTALLATION INSTRUCTION Vanities & Wall Sconce WS-85618 WS-85618 WARNING IMPORTANT: NEVER attempt any work without shutting off the electricity. - Read all instructions before installing. - System is intended for installation by a qualified electrician in accordance

More information

LED Garage Light INSTALLATION INSTRUCTIONS. *Model number noted on carton label

LED Garage Light INSTALLATION INSTRUCTIONS. *Model number noted on carton label LED Garage Light *Model number noted on carton label INSTALLATION INSTRUCTIONS Model Number / Número de Modelo / Numéro des modèle SGLL 24 PIR (24 LED Garage Light) Actual Dimensions 10 W x 3-1/2 H x 24-1/2

More information

CLARA CLA SUSPENDED, WALL, SURFACE

CLARA CLA SUSPENDED, WALL, SURFACE CLARA CLA STANDARD SIZES 4.75" Hollow Lensed Body Configurable in 2ft increments (suspended mount) ADA-Compliant 2ft/4ft wall sconce LAMPING LED - 80+ CRI - 3000K/3500K/4000K Dimming down to 0% FINISH

More information

General Installation Instructions LED

General Installation Instructions LED General Installation Instructions LED To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions and other hazards, please read all warnings

More information

ALL W INSTALLATION INSTRUCTIONS

ALL W INSTALLATION INSTRUCTIONS ALL1000-3300W INSTALLATION INSTRUCTIONS Aladdin Light Lift, Inc. (256) 429-9700 61 Shields Road (877) 287-4601 Huntsville, AL 35811 www.aladdinlightlift.com Patent #5105349 WARNING: Disconnect power source

More information

97Ti, 95Ti, 93T Treadmills Assembly Instructions

97Ti, 95Ti, 93T Treadmills Assembly Instructions 97Ti, 95Ti, 9T Treadmills Assembly Instructions ongratulations... and welcome to the world of The following Parts Identification Listing and the step by step assembly procedures have been assembled to

More information

Installation Instructions

Installation Instructions Installation Instructions If you have questions, call 800-GE-CARES or visit our website at: www.monogram.com 30", 36" and 48" Professional Restaurant Style Vent Hoods Models: ZV48R ZV36R ZV30R 1 Monogram.

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS LED LIGHT ENGINE APPLICATION PROGRAM INSTALLATION INSTRUCTIONS LED Light Engine Kit Model: 9 Round Engine 120V: TRIAC DIMMING TKT120025RDxx-01 TKT120025RDxx-11 TKT120021RDxx-01 TKT120021RDxx-11 TKT120025RDxx-02

More information

Installation Instructions

Installation Instructions Installation Instructions If you have questions, call 800.GE.CARES or visit our website at: www.monogram.com 30", 36" and 48" Professional Restaurant Style Vent Hoods Models: ZV48R ZV36R ZV30R 1 Installation

More information

Installation Instructions

Installation Instructions PART NUMBER: CPLPCONV007A00 60,000---130,000 BTU/HR 2TO5TONS SMALL PACKAGED PRODUCTS GAS HEATING/ELECTRIC COOLING UNITS HIGH ALTITUDE ONLY 2001---6000 FT PROPANE CONVERSION KIT Installation Instructions

More information

Installation Instructions

Installation Instructions at :: rangehoods. com Call 1-800-667-8721 anywhere in the US and Canada - www.rangehoods.com Installation Instructions ZV950 36" Stainless Steel Vent Hood Monogram. We bring good things to life. GE Monogram

More information

ALL700RM-230V INSTALLATION INSTRUCTIONS

ALL700RM-230V INSTALLATION INSTRUCTIONS ALL700RM-230V INSTALLATION INSTRUCTIONS Aladdin Light Lift, Inc. (256) 429-9700 61 Shields Road (877) 287-4601 Huntsville, AL 35811 www.aladdinlightlift.com Patent #5105349 WARNING: Disconnect power source

More information

Installation Instructions

Installation Instructions Installation Instructions If you have questions, call 800.GE.CARES or visit our website at: www.monogram.com 30", 36" and 48" Professional Vent Hoods Models: ZV48T, ZV48S ZV36T, ZV36S ZV30T, ZV30S 1 Installation

More information

LED VaporProof Fixture

LED VaporProof Fixture ASD LED VaporProof Fixture is a modern lighting fixture widely used in different environments. Besides contemporary design, it has a row of features that makes it a perfect choice for everyone. Its main

More information

QTM-eLED INSTALLATION INSTRUCTIONS Must be installed by licensed electrician.

QTM-eLED INSTALLATION INSTRUCTIONS Must be installed by licensed electrician. INSTALLATION INSTRUCTIONS Must be installed by licensed electrician. CLASS: 3425-15 3425-95 2017.V01 is Q-Tran s interior rated electronic power supply, utilizing the Xitanium driver from Advance. Suitable

More information

LST Solid-State Starter User s Manual TB WOOD S INCORPORATED

LST Solid-State Starter User s Manual TB WOOD S INCORPORATED Form 1276A TM LST Solid-State Starter User s Manual TB WOOD S INCORPORATED Chambersburg, Pennsylvania TRADEMARK NOTICE TB Wood s and are registered trademarks of TB Wood s Incorporated. is a trademark

More information

ILLUMINA BS100 INSTALLATION INSTRUCTIONS FLUORESCENT VAPOR TIGHT

ILLUMINA BS100 INSTALLATION INSTRUCTIONS FLUORESCENT VAPOR TIGHT 082114EC ILLUMINA BS100 INSTALLATION INSTRUCTIONS FLUORESCENT VAPOR TIGHT Beghelli Canada 3900 14th Avenue Markham, Ontario L3R 4R3 Canada P: (905) 948-9500 F: (905) 948-8673 www.beghellicanada.com Beghelli

More information

Cable Cubby 1202 and 1402 Installation Guide

Cable Cubby 1202 and 1402 Installation Guide Cable Cubby 0 and 40 Installation Guide IMPORTANT: Go to www.extron.com for the complete user guide, installation instructions, and specifications. This guide provides instructions for an experienced technician

More information

MONORAIL KITS INSTALLATION INSTRUCTIONS PENDANTS

MONORAIL KITS INSTALLATION INSTRUCTIONS PENDANTS MONORAIL KITS PENDANTS JESCO Lighting Group is a UL and ETL listed company Copyright 2011 JESCO Lighting Group. All rights reserved. IMPORTANT SAFETY INSTRUCTIONS Be sure to read and unsderstand the following

More information

ALL200RM/ALL200RM-CM

ALL200RM/ALL200RM-CM ALL200RM/ALL200RM-CM INSTALLATION INSTRUCTIONS Aladdin Light Lift, Inc. (256) 429-9700 61 Shields Road (877) 287-4601 Huntsville, AL 35811 www.aladdinlightlift.com Patent #5105349 WARNING: Disconnect power

More information

MOONRING 1 LP1/MR1 Suspended, Surface LED

MOONRING 1 LP1/MR1 Suspended, Surface LED MOONRING 1 LP1/MR1 LED Find additional images and information at alwusa.com/moonring 1. BASE MODEL LP1/MR1SD 1" suspended direct LPI/MR1SI 1" suspended indirect LP1/MR1SMB 1" wall/surface back-mounted,

More information

INSTALLATION GUIDE FOR VM-3000 SERIES INTEGRATED VOICE EVACUATION SYSTEM

INSTALLATION GUIDE FOR VM-3000 SERIES INTEGRATED VOICE EVACUATION SYSTEM For Service Technicians only INSTALLATION GUIDE FOR VM-3000 SERIES INTEGRATED VOICE EVACUATION SYSTEM This manual describes works to be performed with the unit's case open. Leave all these works to a qualified

More information

MONORAIL KITS INSTALLATION INSTRUCTIONS SPOTS

MONORAIL KITS INSTALLATION INSTRUCTIONS SPOTS MONORAIL KITS INSTALLATION INSTRUCTIONS SPOTS JESCO Lighting Group is a UL and ETL listed company Copyright 2011 JESCO Lighting Group. All rights reserved. IMPORTANT SAFETY INSTRUCTIONS Be sure to read

More information

Assembly instruction. Pendant Light Toccata GENERAL REMARKS ON SAFETY: Technical data: BOM

Assembly instruction. Pendant Light Toccata GENERAL REMARKS ON SAFETY: Technical data: BOM GENERAL REMARKS ON SAFETY: Read all of these instructions before installing fixtures. Keep all of the instructions for future reference. Turn off power before installing fixture. Installation is to be

More information

M Remote Mounting Kit

M Remote Mounting Kit M9203-100 Remote Mounting Kit M9203-100 Part No. 34-636-2308, Rev. A Issued August 29, 2014 Applications IMPORTANT: Use this M9203-100 Remote Mounting Kit only to control equipment under normal operating

More information

NOVENTA NV3.5 SUSPENDED, WALL, SURFACE, RECESSED. STANDARD SIZES 3.5" Aperture corner profile Configurable in individual straight run sections

NOVENTA NV3.5 SUSPENDED, WALL, SURFACE, RECESSED. STANDARD SIZES 3.5 Aperture corner profile Configurable in individual straight run sections NOVENTA NV3.5 SUSPENDED,, SURFACE, RECESSED STANDARD SIZES 3.5" Aperture corner profile Configurable in individual straight run sections LAMPING LED - Direct or Indirect - 80/90 CRI - 3000K/3500K/4000K

More information

LIGHTPLANE 1 RECESSED - LP1R

LIGHTPLANE 1 RECESSED - LP1R INSTRUCTIONS LIGHTPLANE 1 RECESSED - LP1R Safety & Warnings! When installing or using this recessed fixture basic safety precautions should be followed: 1. Read ALL INSTRUCTIONS before installing 2. This

More information

INSTRUCTIONS. Power Panel. Installation Instructions

INSTRUCTIONS. Power Panel. Installation Instructions Overview LuXout Shade 18 Output - For use with LuXout Shades NOTICE: This power supply is built-in fan on/off control circuit. Fan automatically works according to working temperature. SHOCK HAZARD Risk

More information

MODELS. 2 & 4 Low Profile Linears

MODELS. 2 & 4 Low Profile Linears INSTALLATION AND MAINTENANCE MANUAL SAFESITE LED LINEAR FIXTURE Document No: 9100-127-2182-99 Rev D December, 2016 MODELS 2 & 4 Low Profile Linears These instructions contain important safety information,

More information

M Remote Mounting Kit

M Remote Mounting Kit M9208-250 Remote Mounting Kit Installation Instructions M9208-250 Part No. 34-636-2200, Rev. A Issued August 29, 2014 Applications IMPORTANT: Use this M9208-250 Remote Mounting Kit only to control equipment

More information

Installation Instructions If you have questions, call 800-GE-CARES or visit our website at:

Installation Instructions If you have questions, call 800-GE-CARES or visit our website at: Installation Instructions If you have questions, call 800-GE-CARES or visit our website at: www.monogram.com 30", 36" and 48" Professional Vent Hoods Models: ZV48T, ZV48S ZV36T, ZV36S ZV30T, ZV30S Monogram.

More information

UV8 & UV90 SERIES INSTALLATION INSTRUCTIONS

UV8 & UV90 SERIES INSTALLATION INSTRUCTIONS UV8 & UV90 SERIES INSTALLATION INSTRUCTIONS Important THIS SHEET CONTAINS IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS. Warning This product must be installed in accordance with National Electrical

More information

CSR COMPACT FUSED INTERLOCKED ARKTITE RECEPTACLE - 30 & 60 AMP Installation & Maintenance Information IF 1440

CSR COMPACT FUSED INTERLOCKED ARKTITE RECEPTACLE - 30 & 60 AMP Installation & Maintenance Information IF 1440 CSR COMPACT FUSED INTERLOCKED ARKTITE RECEPTACLE - 30 & 60 AMP Installation & Maintenance Information IF 1440 APPLICATION SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE CSR compact fused interlocked ARKTITE

More information

ASSEMBLY AND INSTALLATION INSTRUCTIONS

ASSEMBLY AND INSTALLATION INSTRUCTIONS ASSEMBLY AND INSTALLATION INSTRUCTIONS T0068 WARNING: BE SURE TO SHUT OFF POWER AT THE MAIN FUSE OR CIRCUIT BREAKER BOX BEFORE INSTALLING OR SERVICING THIS FIXTURE. NOTE: 1. Before installing, consult

More information

FIVE BOW FB Suspended, Surface LED

FIVE BOW FB Suspended, Surface LED FIVE BOW FB LED Find additional images and information at alwusa.com/fb 1. BASE MODEL FBD 1.75" suspended, direct FBI 1.75" suspended, indirect FBSMB 1.75" suspended, surface-mount Page 2 of 6 Type: 2.

More information

MODELS 2 & 4 Top Conduit Linears

MODELS 2 & 4 Top Conduit Linears INSTALLATION AND MAINTENANCE MANUAL SAFESITE AND DUROSITE LED LINEAR FIXTURE Document No: 9100-127-1885-99 Rev E December, 2016 MODELS 2 & 4 Top Conduit Linears These instructions contain important safety

More information

OmniAire Omnitec Design, Manufacturing Air Purification Equipment Since 1988

OmniAire Omnitec Design, Manufacturing Air Purification Equipment Since 1988 OmniAire 18000 Omnitec Design, Manufacturing Air Purification Equipment Since 1988 For your larger projects the OmniAire 18000 is the right tool. The modular design of this system allows for ease of transport

More information

Silvus TM 30 Exterior

Silvus TM 30 Exterior Components included Sconce and Mounting Plate with Locking Plate attached. Three wire connectors and one washer 30 fixture 60 fixture Marked Marked -to-module wiring cable included with (60 only) Marked

More information

Installation Instruction

Installation Instruction T F W 604.549.9379 604.549.9555 fluxwerx.com Installation Instruction DRIVER ENCLOSURE Ceiling Type Version Grid Battery Pack GRID MOUNT INSTALL OPTIONS OPTION 1: Standard Vertical Grid drivers can be

More information

SQUIGGLY Flexible LED Tape Light

SQUIGGLY Flexible LED Tape Light U isted Field Cuttable 12VDC IDOOR OY WET OCATIO SAFETY & WARIGS 1. Install in accordance with national and local electrical code regulations. 2. This product is intended to be installed and serviced by

More information

Installation Instructions

Installation Instructions at :: rangehoods. com Call 1-800-667-8721 anywhere in the US and Canada - www.rangehoods.com Installation Instructions 30", 36" and 48" Restaurant Style Vent Hoods Models: ZV48R ZV36R ZV30R Monogram. We

More information

INSTALLATION GUIDE Works in double and single ended wiring.

INSTALLATION GUIDE Works in double and single ended wiring. ISTAATIO GUIDE Works in double and single ended wiring. -1- Safety Precautions For your and others safety, please read the precaution carefully before installation: (1). Product should be installed by

More information

Have a bright day! Nicholas Harmon President, Verilux, Inc.

Have a bright day! Nicholas Harmon President, Verilux, Inc. Model: VF02 Dear Customer, Thank you for purchasing the Verilux EasyFlex Deluxe Natural Spectrum Floor Lamp. You have received a quality product, backed by a one year limited warranty. As a Verilux customer,

More information

Operation/Installation Instructions

Operation/Installation Instructions Important Information These instructions contain safety information, read and follow them carefully. Dialight will not accept any responsibility for injury, damage or loss which may occur due to incorrect

More information

Brighter lights, Softer sounds.

Brighter lights, Softer sounds. Tone 29X Brighter lights, Softer sounds. cycle + tone Tone is an add-on acoustic accessory conceived for our Cycle luminaire. It absorbs reverberated noise and helps reduce the echo of background sounds

More information

Installation Instructions

Installation Instructions Installation Instructions If you have questions, call 800.GE.CARES or visit our website at: www.monogram.com ZV950 36" Stainless Steel Vent Hood Safety Information BEFORE YOU BEGIN Read these instructions

More information

Operating Instructions

Operating Instructions CIDII & CIIDI Rated LED High Bay / Flood Light Luminaire Important Information: These instructions contain safety information; read and follow them carefully. Dialight will not accept any responsibility

More information