RESIDENTIAL & LIGHT COMMERCIAL AIR CONDITIONING

Size: px
Start display at page:

Download "RESIDENTIAL & LIGHT COMMERCIAL AIR CONDITIONING"

Transcription

1 RESIDENTIAL & LIGHT COMMERCIAL AIR CONDITIONING

2 Panasonic Air Conditioning Designed To Care For Your Projects Since the sale of Panasonic s room air conditioner in 1958, we have worked towards providing products and solutions that create comfortable and healthy living spaces for users. In addition to comfort, we have always championed in the consideration of installation ease, diversity of installation environments, and the needs of all stakeholders. Consequently, Panasonic has developed smart control management solutions allowing you to synergistically control and monitor the systems energy consumptions, hence removing the restrictions of traditional systems. 2

3 Outdoor Unit P. 6-9 CONTENTS Product Line-up 4-5 Outdoor Unit Splittable Ducted The new model debuts with R32 refrigerant. Its compact body allows installation even in narrow spaces. Splittable Ducted P Indoor Unit High Static Pressure Splittable Ducted High Static Pressure Ducted Mid Static Pressure Ducted Way Cassette Under Ceiling Wall Mounted Products for Small Sized Project The new High Static Pressure design splits the unit into 3 components f Smart Control Management Solutions PAC/VRF Smart Connectivity Panasonic AC Smart Cloud Controllers Smart Control Management Solutions P Panasonic s Smart Control Management Solutions allow multiple sites to be monitored simultaneously. Control each sites Indoor Air Quality and power consumption all from your portable devices. 3

4 Product Line-up Cooling Capacity Ducted High Static Pressure Model Page for 6.0kW -16.0kW ECONAVI ready Splittable Ducted High Static Pressure Model Page for 18kW kW For Medium Sized Project Indoor Unit Ducted Mid Static Pressure Model Page Way Cassette * Panel is provided as an option (CZ-KPU3/CZ-KPU3A) Page Under Ceiling Page ECONAVI ready ECONAVI ready ECONAVI ready Wall Mounted Page ECONAVI ready R410A Deluxe Model Page 6-9 Outdoor Unit R32 Compact Model Page 6-9 Cooling Capacity 2.5/2.6 kw 3.4/3.7 kw 4.8/5.0 kw Ultra Slim Ducted Page CS-E9SD3RW CS-E12SD3RW CS-E18SD3RW For Small Sized Project Indoor Unit Bulkhead Ducted Page Mini Cassette Page CS-E9QD3RW CS-E9SB4RW CS-E12QD3RW CS-E12QB4RW CS-E18QD3RW CS-E18QB4RW Outdoor Unit R410A Model Page CU-E9SD3R CU-E9QD3R CU-E9SB4R CU-E12SD3R CU-E12QD3R CU-E12QB4R CU-E18SD3R CU-E18QD3R CU-E18QB4R 4

5 6.0kW 7.1kW 10.0kW 12.5kW 14.0kW 16.0kW 18.0kW 20.0kW 22.4kW S-60PE1R5B S-71PE1R5B S-100PE1R5B S-125PE1R5B S-140PE1R5B S-160PE1R5A S-180PE3R5 S-200PE3R5 S-224PE3R5 S-60PF1E5B S-71PF1E5B S-100PF1E5B S-125PF1E5B S-140PF1E5B S-60PU2E5B S-71PU2E5B S-100PU2E5B S-125PU2E5B S-140PU2E5B S-60PT2E5B S-71PT2E5B S-100PT2E5B S-125PT2E5B S-140PT2E5B S-100PK2E5B U-160PE2R8A* U-180PE2R8A* U-200PE2R8A* U-224PE2R8A* * 3 phase U-60PZ2R5 U-71PZ2R5 U-100PZ2R5 U-100PZ2R8* U-125PZ2R5 U-125PZ2R8* U-140PZ2R5 U-140PZ2R8* * 3 phase 5

6 Outdoor Unit The Panasonic outdoor unit has been designed with all stakeholders front of mind. The new R32 compact unit has been intuitively designed with a single fan body, allowing prodigiously powerful performance to be installed in even the tightest of spaces. R32 Compact Model Compact Design Whilst maintaining its powerful performance, the new R32 compact unit is even smaller. This enables them to be installed in a vast variety of even tighter places. Industry-leading Small Body with All 1-fan Models* Panasonic s ingeniously designed R32 outdoor units are compact in size to fit into any space and layout. This makes them easy to install even in the tightest of places. *Up to 14.0kW kW Model Conventional Model R32 Compact 6.0/7.1kW Model 2018 Model 695mm Conventional Model Approx. 40% * Volume Decrease 996mm 2018 Model Approx. 20% * Volume Decrease 875mm 320mm 980mm 370mm Height 996mm 695mm 301 mm Shorter Height 1,416mm 996 mm 420 mm Shorter Weight 68kg 44kg 24kg Lighter * Comparison between U-60PZ2R5 and U-60PE1R5A Weight 98kg 90kg 8kg Lighter * Comparison between U-100PZ2R5 and U-100PE1R5A 6

7 Outdoor Unit Features Precise Temperature Control Constant Comfort Air Conditioning Another advantage of Panasonic Premium Inverter technology includes its ability to ensure precise temperature control and offer a wider power output range to perform in even the most extreme conditions in Australia, ensuring constant comfort. R32 Compact Low Room Temp. Mid Room Temp. High Room Temp. Panasonic Comfort Comfort 3.0kW 11.5kW Up to 15% Greater Performance Brand X Over Cooling 5.0kW 10.0kW Under Cooling 0.0kW 5.0kW 10.0kW 15.0kW Graph shows each models 10.0kW Inverter High Static Pressure Ducted systems performance range during cooling. Energy Saving Technology High EER and COP Value The use of energy saving design for the structure of fans, fan motors, compressors and heat exchangers resulted in high EER and COP value which ranked as one the top class in the industry. R32 Compact Cooling (EER) Heating (COP) PU PU kW 7.1kW 10.0kW 12.5kW 14.0kW 0 6.0kW 7.1kW 10.0kW 12.5kW 14.0kW * The graph shows 4-way cassette R32 models values 7

8 Other Advanced Technology Increased Piping Length for Greater Design Flexibility Adaptable to various building types and sizes Max. piping length : 40m (6.0kW, 7.1kW), 50m (10.0kW-14.0kW), 50m (16.0kW-22.4kW) R32 Compact R410A Deluxe Product Quality and Safety R32 Compact R410A Deluxe All Panasonic air conditioners undergo strict quality and safety tests before sale. This rigorous process includes obtaining all necessary Safety Approvals, to ensure that all air conditioners we sell are not only built to the highest market standards, but are also completely safe. Height difference 30m* *15m if the outdoor unit is below the indoor unit Quiet Mode Quiet mode reduces outdoor operating sound by 2dB. External input signal is also available. * 14.0kW or smaller capacity unit R32 Compact R410A Deluxe Demand Response Compliant R32 Compact R410A Deluxe Panasonic air conditioners are equipped with a Demand Response Enabling Device (DRED) which complies to both AS 4755 and AS Panasonic continues to design and develop products that are tailored to local needs and requirements. The Equipment Energy Ef iency (E3) program has been supporting the development of DRED standards for air-conditioners which should comply with AS The functionality will be required for all installations in the very near future. DRM1 DRM2 DRM3 Terminal block C Demand controller Outdoor unit Demand control terminal is available to control % of capacities. Outdoor Unit Dimensions R32 Compact Model Dimensions (6.0kW 7.1kW) (25) 695 8

9 Outdoor Unit Features R32 Compact Model Dimensions (10.0kW 14.0kW) 1) Mounting hole (4-R6.5), anchor bolt : M10 2) Refrigerant tubing (liquid tube), red connection (Ø9.52) 3) Refrigerant tubing (gas tube), red connection (Ø15.88) 4) Refrigerant tubing port 5) Electrical wiring port (ø13) 6) Electrical wiring port (ø22) 7) Electrical wiring port (ø27) 8) Electrical wiring port (ø35) (10) Air intake Unit: mm (18) (24) 49 (56) Ø32 holes (holes for drain) When using a drain pipe, install the drain socket (field supply) on to the drain port.seal the other drain port with the rubber cap. 36 Air discharge A VIEW A VIEW Air discharge Air intake Z VIEW Z VIEW 74 4 R410A Deluxe Model Dimensions (16.0kW 22.4kW) Mounting hole (4-R6.5), anchor bolt : M10 Refrigerant tubing (liquid tube), flared connection (ø12.7) Refrigerant tubing (gas tube), flared connection (ø19.05)* Refrigerant tubing port Electrical wiring port (ø13) Electrical wiring port (ø22) Electrical wiring port (ø27) Electrical wiring port (ø35) Specifi cation for pipe connecting indoor unit to outdoor unit. *1 (Gas piping connection) While the main gas side pipe is ø25.4, since connecting the outdoor unit's 3-way valve requires a ø19. flare, please be sure to use standard accessories joint piping B or A for connection (brazing), and connect as follows. (10) Air intake Air-discharge holes (holes for drain) A Enlarged view A Air-discharge Air intake B Enlarged view B

10 Splittable Ducted Create comfort faster. The newly designed high static pressure ducted model is improved for a more flexible installation. By dividing the unit into 3 components, the burden of installation is reduced. * In the case of the S-180PE3R5, S-200PE3R5, and S-224PE3R5. Powerful Air for Quick Comfort Providing powerful air, Panasonic s splittable ducted temperature control. 16% * Greater Performance Previous Model 1,200 l/s New Model 1,400* l/s * Comparison between S-224PE3R5 and S-224PE2R5B Max.200Pa Static Pressure Setting A maximum static pressure setting of a powerful 200Pa enables the use of long ducts for installation in a wide range of spaces. Ideal for large-scale houses, nd restaurants. 3-step Static Pressure Set Up You can select between the three Static Pressure modes of 200Pa / 130Pa / 75Pa for extra installation exibility. 75Pa* Factory Setting 130Pa* 200Pa* * In case of S-224PE3R5 * In case of S-224PE3R5 10

11 Splittable Ducted Easy Installation Design Fits the Roof-space and Your Needs The newly designed high static pressure ducted consists of 3 components, the heat exchanger, the fan and the fan casing. For easy installation, the unit has been designed to be lifted into the roof via return air grille, separated, and easily reassembled when in position. Heat Exchanger Fan Fan Casing S-180PE3R5 916mm New 486mm Ducted Model Key Factors Bell Shaped Keyhole for Weight Compared Support to conventional models, the new Panasonic splittable ducted weighs in at approximately 10%* lighter. This notion is further emphasised by the unit s ability to split into three components, 1,456mm Part of the keyhole is newly the heaviest of which totals at 48kg. designed with a bell shape * Comparison between S-180PE3R5 and S-180PE2R5B to reduce the burden of installation. It also enables temporary attachment. 2 Wire Connectors for Easy Installation With only 2 wire connectors, installation has become much easier and faster. 12 Bolts & Screws for Easy Assembly Only 12 screws and bolts need to be attached, allowing for a shorter installation time. Easy Assembly Steps Assembly takes three easy steps, even in limited spaces. Easy Assembly Steps Assembly takes three easy steps, even in limited spaces. Install the fan to the heat exchanger and tighten the Assemble the connectors. 2 screws and bolts. 1 3 Install the chassis and tighten the screws and bolts. 11

12 Indoor Unit High Static Pressure Splittable Ducted High static and large airflow ducted for exceptional installation flexibility. DC motor Self-diagnosing Function Automatic Fan Operation Mild dry Automatic Restart Function DC Motor Technical focus Easy installation with splittable chassis design Maximum 200Pa static pressure setting* Design exibility thanks to high static pressure and large air volume Low power input Accurate temperature control to reduce cold drafts during operation DC motor equipped * In case of S-224PE3R5 HIGH STATIC PRESSURE SPLITTABLE DUCTED Dimensions (18.0kW 22.4kW) 1 Refrigerant liquid tubing (Flare) Type 180 : ø9.52 Type 200/224 : ø Refrigerant gas tubing (Brazing) ø19.05 (Type 200/224 (30-50m) : Connection tubing ø Power supply port 4 Communication port 5 Drain port 25A ø25.4) hole (Suspension bolt pitch) hol e hol e (Suspension bolt pitch) pitch = pitch = (Suspension bolt pitch) (Suspension bolt pitch) Electrical component box unit: mm

13 High Static Pressure Splittable Ducted CZ-RTC5B CZ-RTC4 S-180PE3R5 S-200PE3R5 S-224PE3R5 Capacity 18.0kW 20.0kW 22.4kW Model Name Indoor Unit S-180PE3R5 S-200PE3R5 S-224PE3R5 Outdoor Unit U-180PE2R8A U-200PE2R8A U-224PE2R8A Cooling capacity : Heating capacity kw BTU/h 18.0 ( ) 20.0 ( ) 61,400 (18,400-68,200) 68,200 (19,100-76,400) 20.0 ( ) 22.4 ( ) 68,200 (21,500-76,400) 76,400 (24,200-85,300) 22.4 ( ) 25.0 ( ) 76,400 (21,500-85,300) 85,300 ( ,500) EER : COP W/W 3.02 : : : : : : 3.52 Total power input Cooling : Heating kw 5.96 : : : 7.10 Indoor Unit Power source Phase/Hz 1 Phase/ 50Hz 1 Phase/ 50Hz 1 Phase/ 50Hz V 230V 240V 230V 240V 230V 240V Current Cooling : Heating A 3.10 : : : : : : 4.10 Dimensions H W D mm 486 x 1456 x x 1456 x x 1456 x 916 Heat exchanger H W D mm 486 x 1,456 x x 1,456 x x 1,456 x 558 Fan H W D mm 377 x 1,150 x x 1,150 x x 1,150 x 427 Case H W D mm 434 x 1,178 x x 1,178 x x 1,178 x 360 Net weight kg Air volume Cooling : Heating L/s 1,200 / 1,050 / 883 : 1,200 / 1,050 / 883 1,200 / 1,050 / 883 : 1,200 / 1,050 / 883 1,400 / 1,200 / 983 : 1,400 / 1,200 / 983 External static pressure Pa 60 (Max.150) 75 (Max.180) 75 (Max.200) Sound pressure level (H/M/L) Sound power level (H/M/L) Cooling : Heating db(a) 46 / 44 / 41 : 46 / 44 / / 44 / 41 : 46 / 44 / / 45 / 42 : 47 / 45 / 42 Cooling : Heating db(a) 78 / 76 / 73 : 78 / 76 / / 76 / 73 : 78 / 76 / / 77 / 74 : 79 / 77 / 74 Number of fan speeds Drain pipe size mm VP-25 VP-25 VP-25 Outdoor Unit Power source Phase/Hz 3 Phase/ 50Hz 3 Phase/ 50Hz 3 Phase/ 50Hz V 400V 415V 400V 415V 400V 415V Current Cooling : Heating A 8.55 : : : : : : 9.50 Dimensions H W D mm 1500 x 980 x x 980 x x 980 x 370 Net weight kg Air volume Cooling : Heating L/s 2,733 : 2,733 2,666 : 2,666 2,666 : 2,666 Sound pressure level (Silent mode) Sound power level (Silent mode) Cooling : Heating db(a) 59 (57) : 61 (59) 60 (58) : 62 (60) 60 (58) : 62 (60) Cooling : Heating db(a) 77 (75) : 79 (77) 79 (77) : 81 (79) 79 (77) : 81 (79) Piping connections Liquid/Gas m Ø9.52 / Ø19.05 Ø12.7 / Ø19.05 Ø12.7 / Ø19.05 Pipe length min. - max. m Elevation difference (OU located lower, OU located higher) Maximum chargeless length Refrigerant at shipping, Additional gas amount m 30, 30 30, 30 30, 30 m g R410A, 5,600, 50 (g/m) R410A, 6,400, 80 (g/m) R410A, 6,400, 80 (g/m) Operation ranges Cooling : Heating C -15 to 46 : -20 to to 46 : -20 to to 46 : -20 to 24 13

14 14

15 High Static Pressure Ducted Indoor Unit High Static Pressure Ducted High static and large airflow ducted for exceptional installation flexibility. S-60PE1R5B S-71PE1R5B S-100PE1R5B CZ-CENSC1 ECONAVI ready CZ-RTC5B Self-diagnosing Function Automatic Fan Operation Mild dry Automatic Restart Function S-125PE1R5B S-140PE1R5B S-160PE1R5A CZ-RTC4 Compact Body Size Hidden in the ceiling, ideal when interior decor is an important consideration such as in residences with many rooms and light commercial buildings. 1, , mm (S-60PE1R5B) 360mm (S-71PE1R5B, S-100PER5B) S-60PE1R5B S-71PE1R5B S-100PE1R5B S-125PE1R5B S-140PE1R5B S-160PE1R5A System Example An inspection port (450mm x 450mm or more) is required at the control-box side of the indoor unit body. Rectangle duct Inspection port (450 x 450mm or more) Canvas duct Intake grille Cold Drafts Reduced During Heating Operation Accurate temperature measurement by E1/E2 sensor to reduce cold drafts during heating operation. intake Air sensor E2 sensor E1 sensor 15

16 Capacity 6.0kW 7.1kW 10.0kW Model Name Cooling capacity : Heating capacity Indoor Unit S-60PE1R5B S-71PE1R5B S-100PE1R5B Outdoor Unit U-60PZ2R5 U-71PZ2R5 U-100PZ2R5 kw BTU/h 6.0 ( ) 6.0 ( ) 20,500 (6,800-24,200) 20,500 (6,100-25,900) 7.1 ( ) 7.1 ( ) 24,200 (6,800-27,300) 24,200 (6,100-29,300) 10.0 ( ) 10.0 ( ) 34,100 (10,200-39,200) 34,100 (10,200-47,800) EER : COP W/W 3.23 : : : : : : 3.89 Total power input Cooling : Heating kw 1.86 : : : 2.57 Indoor Unit Power source Phase/Hz 1 Phase/ 50Hz 1 Phase/ 50Hz 1 Phase/ 50Hz V 230V 240V 230V 240V 230V 240V Current Cooling : Heating A 0.85 : : : : : : 1.74 Dimensions H W D mm 290 1,100 (+100) ,100 (+100) ,100(+100) 700 Net weight kg Air volume Cooling : Heating L/s 366 : : : 666 External static pressure Pa 70 (10-100) 100 (10-150) 100 (10-150) Sound pressure level (H/M/L) Cooling : Heating db(a) 43 / 41 / 40 : 43 / 41 / / 44 / 43 : 45 / 44 / / 46 / 44 : 48 / 46 / 44 Sound power level (H/M/L) Cooling : Heating db(a) 60 / 58 / 57 : 60 / 58 / / 61 / 60 : 62 / 61 / / 68 / 66 : 70 / 68 / 66 Number of fan speeds Drain pipe size mm VP-25 VP-25 VP-25 Outdoor Unit Power source Phase/Hz 1 Phase/ 50Hz 1 Phase/ 50Hz 1 Phase/ 50Hz V 230V 240V 230V 240V 230V 240V Current Cooling : Heating A 8.05 : : : : : : 9.50 Dimensions H W D mm 695 x 875 x x 875 x x 980 x 370 Net weight kg Air volume Cooling : Heating L/s 750 : : 750 1,285 : 1,169 Sound pressure level (Silent mode) Cooling : Heating db(a) 46 (44) : 48 (46) 49 (47) : 49 (47) 52 (50) : 52 (50) Sound power level (Silent mode) Cooling : Heating db(a) 65 (63) : 66 (64) 67 (65) : 67 (65) 68 (66) : 67 (65) Piping connections Liquid/Gas m Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Pipe length min. - max. m Elevation difference (OU located lower, OU located higher) m 15, 30 15, 30 15, 30 Maximum chargeless length m Refrigerant at shipping, Additional gas amount g R32, 1,450, 35 (g/m) R32, 1,450, 35 (g/m) R32, 2,600, 45 (g/m) Operation ranges Cooling : Heating C -10 to 43 : -15 to to 43 : -15 to to 43 : -15 to 24 HIGH STATIC PRESSURE DUCTED Dimensions (6.0kW 16.0kW) 2.Gas side (O.D.ø15.88 FLARE, ø19.05 FLARE*) *Only for 16.0kW 3.Drain pipe size (O.D.ø32) 1.Liquid side (O.D.ø9.52 FLARE) model A B C D S-60PE1R5B S-71PE1R5B S-100PE1R5B unit: mm S-125PE1R5B S-140PE1R5B S-160PE1R5A 16

17 High Static Pressure Ducted 12.5kW 14.0kW S-100PE1R5B S-125PE1R5B S-125PE1R5B S-140PE1R5B S-140PE1R5B U-100PZ2R8 U-125PZ2R5 U-125PZ2R8 U-140PZ2R5 U-140PZ2R ( ) 10.0 ( ) 34,100 (10,200-39,200) 34,100 (10,200-47,800) 12.5 ( ) 12.5 ( ) 42,700 (10,900-46,100) 42,700 (11,300-51,200) 12.5 ( ) 12.5 ( ) 42,700 (10,900-46,100) 42,700 (11,300-51,200) 14.0 ( ) 14.0 ( ) 47,800 (11,300-51,200) 47,800 (11,600-54,600) 14.0 ( ) 14.0 ( ) 47,800 (11,300-51,200) 47,800 (11,600-54,600) 3.33 : : : : : : : : : : : : : : : Phase/ 50Hz 1 Phase/ 50Hz 1 Phase/ 50Hz 1 Phase/ 50Hz 1 Phase/ 50Hz 230V 240V 230V 240V 230V 240V 230V 240V 230V 240V 1.72 : : : : : : : : : : ,100(+100) ,100(+100) ,100(+100) ,100(+100) ,100(+100) : : : 833 1,000 : 1,000 1,000 : 1, (10-150) 100 (10-150) 100 (10-150) 100 (10-150) 100 (10-150) 48 / 46 / 44 : 48 / 46 / / 47 / 45 : 49 / 47 / / 47 / 45 : 49 / 47 / / 49 / 47 : 51 / 49 / / 49 / 47 : 51 / 49 / / 68 / 66 : 70 / 68 / / 69 / 67 : 71 / 69 / / 69 / 67 : 71 / 69 / / 71 / 69 : 73 / 71 / / 71 / 69 : 73 / 71 / VP-25 VP-25 VP-25 VP-25 VP-25 3 Phase/ 50Hz 1 Phase/ 50Hz 3 Phase/ 50Hz 1 Phase/ 50Hz 3 Phase/ 50Hz 400V 415V 230V 240V 400V 415V 230V 240V 400V 415V 3.90 : : : : : : : : : : x 980 x x 980 x x 980 x x 980 x x 980 x ,285 : 1,169 1,436 : 1,302 1,436 : 1,302 1,486 : 1,386 1,486 : 1, (50) : 52 (50) 55 (53) : 55 (53) 55 (53) : 55 (53) 56 (54) : 56 (54) 56 (54) : 56 (54) 68 (66) : 67 (65) 70 (68) : 70 (68) 70 (68) : 70 (68) 71 (69) : 71 (69) 71 (69) : 71 (69) Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Ø9.52 / Ø , 30 15, 30 15, 30 15, 30 15, R32, 2,600, 45 (g/m) R32, 2,980, 45 (g/m) R32, 2,980, 45 (g/m) R32, 2,980, 45 (g/m) R32, 2,980, 45 (g/m) -10 to 43 : -15 to to 43 : -15 to to 43 : -15 to to 43 : -15 to to 43 : -15 to 24 HIGH STATIC PRESSURE SPLITTABLE DUCTED Dimensions (18.0kW 22.4kW) 1 Refrigerant liquid tubing (Flare) Type 180 : ø9.52 Type 200/224 : ø Refrigerant gas tubing (Brazing) ø19.05 (Type 200/224 (30-50m) : Connection tubing ø Power supply port 4 Communication port 5 Drain port 25A ø25.4) hole (Suspension bolt pitch) hol e hol e (Suspension bolt pitch) pitch = pitch = (Suspension bolt pitch) (Suspension bolt pitch) Electrical component box unit: mm

18 Indoor Unit Mid Static Pressure Ducted Control all aspects of your environment with exceptional performance and quiet operation. A perfect solution when ceiling heights are restricted. ECONAVI ready DC motor Self-diagnosing Function Automatic Fan Operation Mild dry Automatic Restart Function Built-in Drain Pump DC Motor Technical focus Space saving 290mm height DC fan motor for variable external static pressure control Easy to install and maintain Variable external static pressure control Optimal airflow set-up is possible for different ducting design and conditions. Optimal Control by DC Motor For short ducting such as hotels 10Pa 150Pa For long ducting or for usage with high density filter * Please refer to technical documents for detail. System example An inspection port (450 mm x 450mm or larger) is required at the lower side of the indoor unit body. Rectangle duct Canvas duct Inspection port (450 x 450mm or more) Intake grille More powerful drain pump Using a high-lift built-in drain pump, drain piping can be elevated up to 702mm from the base of the unit. Up to 300mm Up to 500mm 202mm 18

19 Mid Static Pressure Ducted ECONAVI ready S-60PF1E5B S-71PF1E5B CZ-CENSC1 CZ-RTC5B CZ-RTC4 S-100PF1E5B S-125PF1E5B S-140PF1E5B Built-in Drain pump (DC motor pump) External electrical equipment box makes maintenance easy Space saving height of 290mm for all models 290mm standardised height provides easy and uniform installation for models with different capacities, especially when ceiling heights are restricted. Built-in filter Side removable filter V-shaped heat exchanger To improve heat exchange ef ciency, an original V-shaped heat exchanger was developed incorporating a conventional high-ef ciency fan and high-ef ciency grooved heat transfer tubes. This increases the heat exchange surface area. Increases surface area 19

20 Capacity 6.0KW 7.1KW 10.0KW Model Name Cooling capacity : Heating capacity Indoor Unit S-60PF1E5B S-71PF1E5B S-100PF1E5B Outdoor Unit U-60PZ2R5 U-71PZ2R5 U-100PZ2R5 kw BTU/h 6.0 ( ) 6.0 ( ) 20,500 (6,800-24,200) 20,500 (6,100-25,900) 7.1 ( ) 7.1 ( ) 24,200 (6,800-27,300) 24,200 (6,100-29,300) 10.0 ( ) 10.0 ( ) 34,100 (10,200-39,200) 34,100 (10,200-47,800) EER : COP W/W 3.80 : : : : : 4.31 Total power input Cooling : Heating kw 1.58 : : : 2.32 Indoor Unit Power source Phase/Hz 1 Phase/ 50Hz 1 Phase/ 50Hz 1 Phase/ 50Hz V 230V 240V 230V 240V 230V 240V Current Cooling : Heating A 0.89 : : : : : : 1.29 Dimensions H W D mm 290 1, , , Net weight kg Air volume Cooling : Heating L/s 350 : : : 533 External static pressure Pa 70 (10-150) 70 (10-150) 100 (10-150) Sound pressure level (H/M/L) Cooling : Heating db(a) 35 / 32 / 26 : 35 / 32 / / 32 / 26 : 35 / 32 / / 34 / 31 : 38 / 34 / 31 Sound power level (H/M/L) Cooling : Heating db(a) 57 / 54 / 48 : 57 / 54 / / 54 / 48 : 57 / 54 / / 56 / 53 : 60 / 56 / 53 Number of fan speeds Drain piping mm VP-25 VP-25 VP-25 Outdoor Unit Power source Phase/Hz 1 Phase/ 50Hz 1 Phase/ 50Hz 1 Phase/ 50Hz V 230V 240V 230V 240V 230V 240V Current Cooling : Heating A 7.05 : : : : : : 9.30 Dimensions H W D mm 695 x 875 x x 875 x x 980 x 370 Net weight kg Air volume Cooling : Heating L/s 750 : : 750 1,285 : 1,169 Sound pressure level Cooling : Heating db(a) 46 (44) : 48 (46) 49 (47) : 49 (47) 52 (50) : 52 (50) Sound power level Cooling : Heating db(a) 65 (63) : 66 (64) 67 (65) : 67 (65) 68 (66) : 67 (65) Piping connections Liquid / Gas m Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Pipe length min. - max. m Elevation difference (OU located lower, OU located higher) m 15, 30 15, 30 15, 30 Maximum chargeless length m Refrigerant at shipping, Additional gas amount g R32, 1,450, 35 (g/m) R32, 1,450, 35 (g/m) R32, 2,600, 45 (g/m) Operation ranges Cooling : Heating C -10 to 43 : -15 to to 43 : -15 to to 43 : -15 to 24 MID STATIC PRESSURE DUCTED Dimensions (6.0kW 7.1kW) 1 Refrigerant piping joint (liquid tube) Ø9.52 Flare 2 Refrigerant piping joint (gas tube) Ø15.88 Flare 3 Upper drain port VP25 (O.D. Ø32 mm) 200 hose supplied 4 Bottom drain port VP25 (O.D. Ø32 mm) 5 Suspension lug ( mm) 6 Power supply outlet 7 Fresh air intake port (Ø150 mm) 8 Flange for air outlet duct Electrical component box min Indoor unit Min.400 Min.250 Electrical component box Inspection access Refrigerant tubing Min ø3holes x 5 = Filter 1067(Suspension bolt pitch) (Flange O.D.) (150) (75) Inspection access 450 x 450 (Field supply) unit: mm

21 Mid Static Pressure Ducted 12.5KW 14.0KW S-100PF1E5B S-125PF1E5B S-125PF1E5B S-140PF1E5B S-140PF1E5B U-100PZ2R8 U-125PZ2R5 U-125PZ2R8 U-140PZ2R5 U-140PZ2R ( ) 10.0 ( ) 34,100 (10,200-39,200) 34,100 (10,200-47,800) 12.5 ( ) 12.5 ( ) 42,700 (10,900-46,100) 42,700 (11,300-51,200) 12.5 ( ) 12.5 ( ) 42,700 (10,900-46,100) 42,700 (11,300-51,200) 14.0 ( ) 14.0 ( ) 47,800 (11,300-51,200) 47,800 (11,600-54,600) 14.0 ( ) 14.0 ( ) 3.66 : : : : : : : : : : ,800 (11,300-51,200) 47,800 (11,600-54,600) 1 Phase/ 50Hz 1 Phase/ 50Hz 1 Phase/ 50Hz 1 Phase/ 50Hz 1 Phase/ 50Hz 230V 240V 230V 240V 230V 240V 230V 240V 230V 240V 1.30 : : : : : : : : : : , , , , , : : : : : (10-150) 100 (10-150) 100 (10-150) 100 (10-150) 100 (10-150) 38 / 34 / 31 : 38 / 34 / / 35 / 32 : 39 / 35 / / 35 / 32 : 39 / 35 / / 36 / 33 : 40 / 36 / / 36 / 33 : 40 / 36 / / 56 / 53 : 60 / 56 / / 57 / 54 : 61 / 57 / / 57 / 54 : 61 / 57 / / 58 / 55 : 62 / 58 / / 58 / 55 : 62 / 58 / VP-25 VP-25 VP-25 VP-25 VP-25 3 Phase/ 50Hz 1 Phase/ 50Hz 3 Phase/ 50Hz 1 Phase/ 50Hz 3 Phase/ 50Hz 400V 415V 230V 240V 400V 415V 230V 240V 400V 415V 3.95 : : : : : : : : : : x 980 x x 980 x x 980 x x 980 x x 980 x ,285 : 1,169 1,436 : 1,302 1,436 : 1,302 1,486 : 1,386 1,486 : 1, (50) : 52 (50) 55 (53) : 55 (53) 55 (53) : 55 (53) 56 (54) : 56 (54) 56 (54) : 56 (54) 68 (66) : 67 (65) 70 (68) : 70 (68) 70 (68) : 70 (68) 71 (69) : 71 (69) 71 (69) : 71 (69) Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Ø9.52 / Ø , 30 15, 30 15, 30 15, 30 15, R32, 2,600, 45 (g/m) R32, 2,980, 45 (g/m) R32, 2,980, 45 (g/m) R32, 2,980, 45 (g/m) R32, 2,980, 45 (g/m) -10 to 43 : -15 to to 43 : -15 to to 43 : -15 to to 43 : -15 to to 43 : -15 to 24 Dimensions (10.0kW 14.0kW) 1 Refrigerant piping joint (liquid tube) Ø9.52 Flare 2 Refrigerant piping joint (gas tube) Ø15.88 Flare 3 Upper drain port VP25 (O.D. Ø32 mm) 200 hose supplied 4 Bottom drain port VP25 (O.D. Ø32 mm) 5 Suspension lug ( mm) 6 Power supply outlet 7 Fresh air intake port (Ø150 mm) 8 Flange for air outlet duct 9 Electrical component box 172 Min Electrical component box Filter 20-ø3holes x 7 = (Suspension bolt pitch) (150) (Flange O.D.) (75) Inspection access 450 x 450 (Field supply) unit: mm min Indoor unit Min.400 Inspection access Refrigerant tubing Min

22 Indoor Unit 4-WAY Cassette Featuring uniform cooling, easy installation, and with a sleek exterior, this unit is the perfect match for your modern home. nanoe X ready DC motor ECONAVI ready Self-diagnosing Function Automatic Fan Operation Mild dry Intelligent Auto Swing Automatic Restart Function Auto Swing (Auto Flap Control) Built-in Drain Pump DC Motor Technical focus Compact design Low sound levels DC fan motor for increased efficiency Powerful drain pump gives 850mm lift Lightweight design Fresh air knockout Branch duct connection Optional air-intake plenum CZ-FDU3 360 Wide & Comfortable Airfl ow Our design features wide-angle outlets and flaps that were designed through expert mechanics and prototype tests. Air from the centre is sent farther and the air blown out of the larger, side flaps, spreads throughout the room. The air comes from all for sides of the unit and expands gently in a circle centred on the indoor unit. Ample airflow: 600 l/s Industry s leading in the 140PU class. Comfort/Quiet Temperature distribution by thermograph (cooling operation) Simulation conditions: P140 4-way ceiling-mounted cassette type in cooling mode / Floor area of 225m 2/ Ceiling height of 3m 360 Wide 1m Wide Flap Adding a sub flap and widening the main flap have reduced turbulence and increased airflow. Also, setting the jetting port at a wider angle allows the airflow to reach the corners of the room more quickly. 3D Turbo Fan Using a twisted 3D blade made the unit slimmer and more compact, while also increasing the airflow. A 5-Speed mode allows the airflow to be adjusted in 5 steps to suit the situation. Conventional New Model Conventional New Model Previous flap Width 48mm Airflow turbulence is generated New flap Width 70mm Airflow turbulence is reduced Sub Flap Φ490 φ485 5 Speed Mode 3 5 * Panasonic in-house data Twisted 3D Blade Airflow increased 9.5%* 22

23 4-Way Cassette AIR INTAKE CHAMBER 1 PANEL (CZ-KPU3/3A) 2 1 Air intake flange (ø100) (field supply). 2 Air intake box CZ-ATU2* for Air intake plenum. 3 Air intake plenum CZ-FDU3 * When using Air intake box (CZ-ATU2), Air intake plenum (CZ-FDU3) required. 3 CZ-CENSC1 Nomal Panel : CZ-KPU3 ECONAVI Panel : CZ-KPU3A CZ-RTC5B CZ-RTC4 OPTIONAL nanoe X KIT CZ-CNEXU1 (CZ-RTC5B is required) S-60PU2E5B S-71PU2E5B S-100PU2E5B S-125PU2E5B S-140PU2E5B High-Ceiling Installation (Up to 5m for 10.0kW+ models) The units can be installed in rooms with high ceilings, where they provide ample floor-level heating in the winter. (See ceiling height guidelines below.) High Ceiling (Factory settings) New model 3.0m 3.6m Capacity S-60PU2E5B, S-71PU2E5B S-100PU2E5B, S-125PU2E5B, S-140PU2E5B Industry s top-class S-100PU2E5B - S-140PU2E5B 4.5m 4.7m 5m Capacity 4-way discharge high ceiling settings2 3-way discharge with the optional air-blocking materials 2-way discharge with the optional air-blocking materials Ceiling height guidelines Indoor unit * 1 settings 4-way discharge High Factory settings 1 ceiling setting 1 High ceiling setting 2 3-way discharge 2-way (optional airblocking materials) discharge (optional air-blocking materials) * 2 60PU-71PU PU, 125PU, 140PU

24 Air Purification by nanoe Technology nanoe is Panasonic s unique air purifying technology. Introduced in 2003, nanoe has brought comfortable, clean air to a wide variety of living environments. By conducting further research & development, Panasonic has now succeeded in developing nanoe X, with dramatically increased performance. nanoe X Improves Air Quality Panasonic s unique nanoe X has an outstanding effect on various air pollutants, including allergens, viruses and bacteria, as well as cigarette and other household odours. It takes reliable air on performance another step forward. Deodorises unpleasant Inhibits *1 *2 *3 odours bacteria and *4 *5 *6 *7 *8 virus Cigarette Food Garbage Sweat Bacteria Virus nanoe X works on the substances responsible for odours to deodorise them. nanoe X suppresses airborne particles including bacteria, viruses and mould. *1 Adhering odour of cigarette [Effectiveness]: Decrease by 1.7 level [Testing Institute]: Gunma Research Center [Test Report No]: No [Result]: Decrease in odour intensity by 0.7 level after 2 hour of operation. *2 Floating odour of cigarette [Effectiveness]: Decrease by 0.8level [Test Lab Size]:136.5m3 [Testing Institute]: Panasonic Corporation Product Analysis Center [Test Report No]: 4AA A01 [Result]: Decrease in odour intensity by 0.8 level after 2 hour of operation. *3 Adhering odour of Meat Grilling [Effectiveness]: Decrease by 0.9 level [Test Lab Size]:67.7m3 [Testing Institute]: Panasonic Corporation Product Analysis Center [Test Report No]: 4AA A03 [Result]: Decrease in odour intensity by 0.9 level after 2 hour of operation. *4 Mould [Effectiveness]: Inhibit Mould Growth [Testing Institute]: Japan Food Research Laboratories [Test Report No]: [Result]: The growth of the subject was inhibited after 8-hour nanoe operation. *5 Bacteria [Effectiveness]: 99% [Testing Institute]: Kitasato Research Center for Environmental Science [Test Report No]: KRCES-Env. Test Report 24_0301_1 [Result]: 99% of deactivation after 4-hour nanoe operation. *6 Bacteria [Effectiveness]: 99% [Testing Institute]: Japan Food Research Laboratories [Test Report No]: [Result]: The growth of the subject was inhibited after 8-hour nanoe operation. *7 Viruses [Effectiveness]: 99% [Testing Institute]: Kitasato Research Center for Environmental Science [Test Report No]: KRCES-Env. Test Report 24_0300_1 [Result]: 99% of deactivation after 6-hour nanoe operation. *8 Viruses [Effectiveness]: 99% [Testing Institute]: Japan Food Research Laboratories [Test Report No]: [Result]: 99% of deactivation after 8-hour nanoe operation. 26 4

25 nanoe X nanoe X Mechanism The amount of OH radicals increases without increasing amount of ozone, leading to improved effectiveness! Generation Mechanism Structure nanoe X is generated from moisture in the air Atomisation electrode OH radical Electron Water Multi-Leader 5-20nm 4.8 trillion *1 *2 *3 How to Deodorise Odour How to Inhibit Bacteria, Virus *4 *5 *6 *7 *8 and Mould 1 nanoe particles reach odours deep inside fabrics 2 OH radicals decompose odour-causing substances 3 Odours are deodorised 1 nanoe particles precisely reach allergens 2 OH radicals degenerate allergen proteins 3 Allergens are inhibited Also Cleans the Air When Not Air Conditioning You can also use nanoe X in Fan mode when you re not cooling or heating the room. For example, you can use nanoe X to effectively suppress bacteria and odours without using excessive electricity when the of e is empty or after business hours in a restaurant. Business Time Simulated image Closed Time Simulated image AC Mode + FAN Mode + nanoe X es the room while maintaining the comfort temperature when people are in presence. After closing shops and facilities, nanoe X can perform air cation while they are not in use. Case Examples of nanoe Office Restaurant Gym Residence 25

26 Capacity 6.0kW 7.1kW 10.0kW Model Name Cooling capacity Heating capacity Indoor Unit S-60PU2E5B S-71PU2E5B S-100PU2E5B Outdoor Unit U-60PZ2R5 U-71PZ2R5 U-100PZ2R5 Panel kw BTU/h Standard type:cz-kpu3:econavi type:cz-kpu3a 6.0 ( ) 6.0 ( ) 20,500 (6,800-24,200) 20,500 (6,100-25,900) Standard type:cz-kpu3:econavi type:cz-kpu3a 7.1 ( ) 7.1 ( ) 24,200 (6,800-27,300) 24,200 (6,100-29,300) Standard type:cz-kpu3:econavi type:cz-kpu3a 10.0 ( ) 10.0 ( ) 34,100 (10,200-39,200) 34,100 (10,200-47,800) EER : COP Cooling : Heating W/W 4.05 : : : : : : 4.93 Total power input Cooling : Heating kw 1.48 : : : 2.03 Indoor Unit Power source Phase/Hz 1 Phase/ 50Hz 1 Phase/ 50Hz 1 Phase/ 50Hz V 230V 240V 230V 240V 230V 240V Current Cooling : Heating A 0.35 : : : : : : 0.75 Dimensions H W D Indoor mm Panel mm 33.5 x 950 x x 950 x x 950 x 950 Net weight Indoor kg Panel kg Air volume Cooling : Heating L/s 350 / 266 / 216 : 350 / 266 / / 266 / 216 : 366 / 266 / / 433 / 300 : 600 / 433 / 300 Sound pressure level (H/M/L) Cooling : Heating db(a) 36 / 31 / 28 : 36 / 31 / / 31 / 28 : 37 / 31 / / 38 / 32 : 45 / 38 / 32 Sound power level (H/M/L) Cooling : Heating db(a) 51 / 46 / 43 : 51 / 46 / / 46 / 43 : 52 / 46 / / 53 / 47 : 60 / 53 / 47 Number of fan speeds 5* 5* 5* Drain pipe size mm VP-25 VP-25 VP-25 Outdoor Unit Power source Phase/Hz 1 Phase/ 50Hz 1 Phase/ 50Hz 1 Phase/ 50Hz V 230V 240V 230V 240V 230V 240V Current Cooling : Heating A 6.95 : : : : : : 8.50 Dimensions H W D mm 695 x 875 x x 875 x x 980 x 370 Net weight kg Air volume Cooling : Heating L/s 750 : : 750 1,285 : 1,169 Sound pressure level (Silent mode) Cooling : Heating db(a) 46 (44) : 48 (46) 49 (47) : 49 (47) 52 (50) : 52 (50) Sound power level (Silent mode) Cooling : Heating db(a) 65 (63) : 66 (64) 67 (65) : 67 (65) 68 (66) : 67 (65) Piping connections m Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Pipe length min. - max. m Elevation difference (OU located lower, OU located higher) m 15, 30 15, 30 15, 30 Maximum chargeless length m Refrigerant at shipping, Additional gas amount g R32, 1,450, 35 (g/m) R32, 1,450, 35 (g/m) R32, 2,600, 45 (g/m) Operation ranges Cooling : Heating C -10 to 43 : -15 to to 43 : -15 to to 43 : -15 to 24 * When using CZ-RTC5B, the number of fan speed will be 3 for other controller. 4-WAY CASSETTE Dimensions (6.0kW 14.0kW) unit: mm A 6.0 ~7.1kW B 10.0 ~14.5kW 700 (Suspension bolt pitch) 418 X 860~910 (Ceiling opening dimensions) 780 (Suspension bolt pitch) (390) XX (410) 860~910 (Ceiling opening dimensions) 1 Air intake 2 Discharge outlet 3 Refrigerant tubing (liquid tube) ø9.52 red) / type ø9.52 red) 4 Refrigerant tubing (gas tube) ø15.88 red) / type ø15.88 red) 5 Drain tube connection port VP25 (outer dia. ø32) 6 Power supply port 7 Discharge duct connection port (ø150) 8 Suspension bolt hole ( elongated hole) 9 Fresh air intake duct connection port (ø100)* 10 ECONAVI sensor (Only CZ-KPU3A) * Necessary to attach duct connecting supplied). 143 Less than Less than 300 Less than Less than Over Less than 35 Over A 256 B (Air intake) 2 (Air intake) <Filter dimension> 520 x 520 x View X Z Y (192) 192 A 124 B Detailed view Y M4 Tapping screw holes M4 Tapping screw holes Drain up View XX Detailed view Z 26 * Adjust the suspension bolt length so that the gap from the lower ceiling surface becomes 30 mm or more (18 mm or more from the lower surface of the body) as shown in the re. When the suspension bolt length is long, it hits the ceiling panel and installation is not possible.

27 4-Way Cassette 12.5kW 14.0kW S-100PU2E5B S-125PU2E5B S-125PU2E5B S-140PU2E5B S-140PU2E5B U-100PZ2R8 U-125PZ2R5 U-125PZ2R8 U-140PZ2R5 U-140PZ2R8 Standard type:cz-kpu3:econavi type:cz-kpu3a 10.0 ( ) 10.0 ( ) 34,100 (10,200-39,200) 34,100 (10,200-47,800) Standard type:cz-kpu3:econavi type:cz-kpu3a 12.5 ( ) 12.5 ( ) 42,700 (10,900-46,100) 42,700 (11,300-51,200) Standard type:cz-kpu3:econavi type:cz-kpu3a 12.5 ( ) 12.5 ( ) 42,700 (10,900-46,100) 42,700 (11,300-51,200) Standard type:cz-kpu3:econavi type:cz-kpu3a 14.0 ( ) 14.0 ( ) 47,800 (11,300-51,200) 47,800 (11,600-54,600) Standard type:cz-kpu3:econavi type:cz-kpu3a 14.0 ( ) 14.0 ( ) 47,800 (11,300-51,200) 47,800 (11,600-54,600) 3.82 : : : : : : : : : : : : : : : Phase/ 50Hz 1 Phase/ 50Hz 1 Phase/ 50Hz 1 Phase/ 50Hz 1 Phase/ 50Hz 230V 240V 230V 240V 230V 240V 230V 240V 230V 240V 0.79 : : : : : : : : : : x 950 x x 950 x x 950 x x 950 x x 950 x / 433 / 300 : 600 / 433 / / 450 / 316 : 616 / 450 / / 450 / 316 : 616 / 450 / / 483 / 333 : 633 / 483 / / 483 / 333 : 633 / 483 / / 38 / 32 : 45 / 38 / / 39 / 33 : 45 / 39 / / 39 / 33 : 45 / 39 / / 40 / 34 : 47 / 40 / / 40 / 34 : 47 / 40 / / 53 / 47 : 60 / 53 / / 54 / 48 : 61 / 54 / / 54 / 48 : 61 / 54 / / 55 / 49 : 62 / 55 / / 55 / 49 : 62 / 55 / 49 5* 5* 5* 5* 5* VP-25 VP-25 VP-25 VP-25 VP-25 3 Phase/ 50Hz 1 Phase/ 50Hz 3 Phase/ 50Hz 1 Phase/ 50Hz 3 Phase/ 50Hz 400V 415V 230V 240V 400V 415V 230V 240V 400V 415V 3.90 : : : : : : : : : : x 980 x x 980 x x 980 x x 980 x x 980 x ,285 : 1,169 1,436 : 1,302 1,436 : 1,302 1,486 : 1,386 1,486 : 1, (50) : 52 (50) 55 (53) : 55 (53) 55 (53) : 55 (53) 56 (54) : 56 (54) 56 (54) : 56 (54) 68 (66) : 67 (65) 70 (68) : 70 (68) 70 (68) : 70 (68) 71 (69) : 71 (69) 71 (69) : 71 (69) Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Ø9.52 / Ø , 30 15, 30 15, 30 15, 30 15, R32, 2,600, 45 (g/m) R32, 2,980, 45 (g/m) R32, 2,980, 45 (g/m) R32, 2,980, 45 (g/m) R32, 2,980, 45 (g/m) -10 to 43 : -15 to to 43 : -15 to to 43 : -15 to to 43 : -15 to to 43 : -15 to 24 27

28 Indoor Unit Under Ceiling Providing outstanding energy-saving performance, comfort and long-distance airflow distribution, these units are perfect for retail stores and schools. ECONAVI ready DC motor Self-diagnosing Function Automatic Fan Operation Automatic Restart Function DC Motor Compact Looking, Stylish, One-Motion Design With its streamlined, one-motion form, the unit looks thin and compact when installed for a neat appearance in any room. When not operating, the louver closes to provide an elegant look while also keeping the unit clean. Energy-Saving Technology Top Class Energy Saving Optimisation of the shape of the casing and fan assures bigger air ow and higher ef Energy-saving performance is top class in the industry. iency. New DC fan motor Large Diagonal Air Flow Fan DC motor Fan diameter φ

29 Under Ceiling S-60PT2E5B S-71PT2E5B S-100PT2E5B S-125PT2E5B S-140PT2E5B ECONAVI ready CZ-CENSC1 CZ-RTC5B CZ-RTC4 Comfortable, Long-Distance Airflow Distribution The shape of the outlet has been optimised to provide long-distance air ow distribution. Even in long rooms, air w reaches every corner for exceptionally comfortable air conditioning. High Ceiling Setting *Setting by remote control Air fl ow distance m 12m 13m 13m *Results are based on specific testing conditions 29

30 Capacity 6.0kW 7.1kW 10.0kW Model Name Indoor Unit S-60PT2E5B S-71PT2E5B S-100PT2E5B Outdoor Unit U-60PZ2R5 U-71PZ2R5 U-100PZ2R5 Cooling capacity : Heating capacity kw BTU/h 6.0( ) 6.0( ) 20,500 (6,800-24,200) 20,500 (6,100-25,900) 7.1( ) 7.1( ) 24,200 (6,800-27,300) 24,200 (6,800-29,300) 10.0 ( ) 10.0 ( ) 34,100 (10,200-39,200)) 34,100 (10,200-47,800) EER : COP W/W 4.05 : : : : : : 4.24 Total power input Cooling : Heating kw 1.48 : : : 2.36 Indoor Unit Power source Phase/Hz 1 Phase/ 50Hz 1 Phase/ 50Hz 1 Phase/ 50Hz V 230V 240V 230V 240V 230V 240V Current Cooling : Heating A 0.41 : : : : : : 0.65 Dimensions H W D mm 235 1, x 1,275 x , Net weight kg Air volume Cooling : Heating L/s 333 : : : 500 Sound pressure level (H/M/L) Cooling : Heating db(a) 38 / 34 / 30 : 38 / 34 / / 35 / 31 : 39 / 35 / / 37 / 35 : 42 / 37 / 35 Sound power level (H/M/L) Cooling : Heating db(a) 56 / 52 / 48 : 56 / 52 / / 53 / 49 : 57 / 53 / / 55 / 53 : 60 / 55 / 53 Number of fan speeds Drain pipe size mm VP-20 VP-20 VP-20 Outdoor Unit Power source Phase/Hz 1 Phase/ 50Hz 1 Phase/ 50Hz 1 Phase/ 50Hz V 230V 240V 230V 240V 230V 240V Current Cooling : Heating A 6.90 : : : : : : 10.0 Dimensions H W D mm 695 x 875 x x 875 x x 980 x 370 Net weight kg Air volume Cooling : Heating L/s 750 : : 750 1,285 : 1,169 Sound pressure level Cooling : Heating db(a) 46 (44) : 48 (46) 49 (47) : 49 (47) 52 (50) : 52 (50) Sound power level Cooling : Heating db(a) 65 (63) : 66 (64) 67 (65) : 67 (65) 68 (66) : 67 (65) Piping connections Liquid/Gas m Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Pipe length min. - max. m Elevation difference (OU located lower, OU located higher) m 15, 30 15, 30 15, 30 Maximum chargeless length m Refrigerant at shipping, Additional gas amount g R32, 1,450, 35 (g/m) R32, 1,450, 35 (g/m) R32, 2,600, 45 (g/m) Operation ranges Cooling : Heating C -10 to 43 : -15 to to 43 : -15 to to 43 : -15 to 24 CEILING Dimensions (6.0kW 14.0kW) 1 Drain port VP20 (inside diameter ø26mm, drain hose supplied) 2 Left drain position 3 Refrigerant liquid tubing (ø9.52mm, re connection) 4 Refrigerant gas tubing (ø15.88mm, re connection) 5 Left side drain hose outlet port (cutout) 6 Tubing hole on wall surface (ø100mm) 7 Upper side tubing port 8 Right side drain hose outlet port (cutout) 9 Wireless remote controller receiver installation location (Suspension bolt pitch) Indoor Units: S-60PT2E5B S-71PT2E5B 1226 (Suspension bolt pitch) Approx. 2 5 Air intake Minimum 50cm Air discharge Over 250 Service space 1275 Over 250 Service space Tubing hole position on wall surface (Figure shows view from front) (Left drain position) (Closed with rubber stopper at time of shipment.) (Gas tubing) 70 (Liquid tubing) 90 (Right drain position) 30

31 Under Ceiling 12.5kW 14.0kW S-100PT2E5B S-125PT2E5B S-125PT2E5B S-140PT2E5B S-140PT2E5B U-100PZ2R8 U-125PZ2R5 U-125PZ2R8 U-140PZ2R5 U-140PZ2R ( ) 10.0 ( ) 34,100 (10,200-39,200) 34,100 (10,200-47,800) 12.5 ( ) 12.5 ( ) 42,700 (10,900-46,100) 42,700 (11,300-51,200) 12.5 ( ) 12.5 ( ) 42,700 (10,900-46,100) 42,700 (11,300-51,200) 13.6 ( ) 14.0 ( ) 46,400 (11,300-51,200) 47,800 (11,600-54,600) 13.6 ( ) 14.0 ( ) 46,400 (11,300-51,200) 47,800 (11,600-54,600) 3.64 : : : : : : : : : : : : : : : Phase/ 50Hz 1 Phase/ 50Hz 1 Phase/ 50Hz 1 Phase/ 50Hz 1 Phase/ 50Hz 230V 240V 230V 240V 230V 240V 230V 240V 230V 240V 0.67 : : : : : : : : : : , , , , , : : : : : / 37 / 35 : 42 / 37 / / 40 / 36 : 46 / 40 / / 40 / 36 : 46 / 40 / / 41 / 37 : 47 / 41 / / 41 / 37 : 47 / 41 / / 55 / 53 : 60 / 55 / / 58 / 54 : 64 / 58 / / 58 / 54 : 64 / 58 / / 59 / 55 : 65 / 59 / / 59 / 55 : 65 / 59 / VP-20 VP-20 VP-20 VP-20 VP-20 3 Phase/ 50Hz 1 Phase/ 50Hz 3 Phase/ 50Hz 1 Phase/ 50Hz 3 Phase/ 50Hz 400V 415V 230V 240V 400V 415V 230V 240V 400V 415V 4.15 : : : : : : : : : : x 980 x x 980 x x 980 x x 980 x x 980 x ,285 : 1,169 1,436 : 1,302 1,436 : 1,302 1,486 : 1,386 1,486 : 1, (50) : 52 (50) 55 (53) : 55 (53) 55 (53) : 55 (53) 56 (54) : 56 (54) 56 (54) : 56 (54) 68 (66) : 67 (65) 70 (68) : 70 (68) 70 (68) : 70 (68) 71 (69) : 71 (69) 71 (69) : 71 (69) Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Ø9.52 / Ø , 30 15, 30 15, 30 15, 30 15, R32, 2,600, 45 (g/m) R32, 2,980, 45 (g/m) R32, 2,980, 45 (g/m) R32, 2,980, 45 (g/m) R32, 2,980, 45 (g/m) -10 to 43 : -15 to to 43 : -15 to to 43 : -15 to to 43 : -15 to to 43 : -15 to Indoor Units: (Suspension bolt pitch) 114 S-100PT2E5B S-125PT2E5B S-140PT2E5B (Suspension bolt pitch) Approx. 2 5 Air intake Minimum 50cm Air discharge Over 250 Service space 1590 Over 250 Service space Tubing hole position on wall surface (Figure shows view from front) (Left drain position) (Closed with rubber stopper at time of shipment.) (Gas tubing) 70 (Liquid tubing) 90 (Right drain position) 31

32 Wall Mounted Providing small, lightweight and low noise level design, it is ideal for small offices and other commercial applications. It also has a stylish smooth design with a washable front panel. ECONAVI ready DC motor Self-diagnosing Function Automatic Fan Operation Mild dry Intelligent Auto Swing Automatic Restart Function Auto Swing (Auto Flap Control) Technical focus Closed discharge port when not in use Lighter and smaller units make installation easy Quiet operation Smooth and durable design Piping outlet in six directions Washable front panel Air distribution is automatically altered depending on the operational mode of the unit Closed discharge port When the unit is turned off, the ap closes completely to prevent entry of dust into the unit and to keep the equipment clean. Quiet operation Low operating noise level makes these units ideal for hotels and hospital applications. Piping outlet in six directions Piping outlet is possible in the six directions of right, right rear, right bottom, left, left rear, left bottom, making installation easier. Washable front panel The indoor unit s front panel can be easily cleaned for trouble-free maintenance. Air distribution is automatically adjusted depending on the operational mode of the unit Air outlet angle is automatically adjusted for cooling and heating operation. F1 F2 F3 F4 F5 Heating: F1 to F5 Cooling: F1 to F3 32

33 Wall Mounted ECONAVI ready CZ-CENSC1 CZ-RTC5B CZ-RTC4 S-100PK2E5B Capacity Model Name Cooling capacity : Heating capacity 9.0kW Indoor Unit S-100PK2E5B S-100PK2E5B Outdoor Unit U-100PZ2R5 U-100PZ2R8 kw BTU/h 9.0 ( ) 9.0 ( ) 30,700 (10,200-33,100) 30,700 (10,200-35,800) 9.0 ( ) 9.0 ( ) 30,700 (10,200-33,100) 30,700 (10,200-35,800) EER : COP W/W 3.47 : : 3.93 Total power input Cooling : Heating kw 2.59 : : 2.29 Indoor Unit Power source Phase/Hz 1 Phase/ 50Hz 1 Phase/ 50Hz V 230V 240V 230V 240V Current Cooling : Heating A 0.68 : : : : 0.66 Dimensions H W D mm 302 x 1,120 x x 1,120 x 236 Net weight kg Air volume Cooling : Heating L/s 367 / 308 / 250 : 367 / 308 / / 308 / 250 : 367 / 308 / 250 Sound pressure level (H/M/L) Sound power level (H/M/L) Cooling : Heating db(a) 49 / 45 / 41 : 49 / 45 / / 45 / 41 : 49 / 45 / 41 Cooling : Heating db(a) 65 / 61 / 57 : 65 / 61 / / 61 / 57 : 65 / 61 / 57 Number of fan speeds 5 5 Drain pipe size mm VP-16 VP-16 Outdoor Unit Power source Phase/Hz 1 Phase/ 50Hz 3 Phase/ 50Hz V 230V 240V 400V 415V Current Cooling : Heating A 11.5 : : : : 3.30 Dimensions H W D mm 996 x 980 x x 980 x 370 Net weight kg Air volume Cooling : Heating L/s 1,285 : 1,169 1,285 : 1,169 Sound pressure level (Silent mode) Sound power level (Silent mode) Cooling : Heating db(a) 52 (50) : 52 (50) 52 (50) : 52 (50) Cooling : Heating db(a) 68 (66) : 67 (65) 68 (66) : 67 (65) Piping connections Liquid/Gas m Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Pipe length min. - max. m Elevation difference (OU located lower, OU located higher) m 15, 30 15, 30 Maximum chargeless length m Refrigerant at shipping, Additional gas amount g R32, 2,600, 45 (g/m) R32, 2,600, 45 (g/m) Operation ranges Cooling : Heating C -10 to 43 : -15 to to 43 : -15 to 24 WALL MOUNTED Dimensions (10.0kW) 236 Symmetry A 30 (415) (570) Minimum space requirements for installation +2 Ø Exterior view of main unit VIEW A (50) 18.5 Detailed view B B Ø Ø5.3 hole C Ø10.5 Ø80 6 (223.5) Liquid connecting tube (400) Gas connecting tube (450) Cutting position when tubing from left side (Right side tubing hole) Ø80 6 Detailed view C unit: mm 33

34 Products for Small Sized Project Product line-up suitable for light to medium commercial and residential applications. Ultra Slim Ducted Technical focus Market-leading Energy Efficiency Only 200mm High Rear or Bottom Return Air Built-in Drain Pump (500mm lift*) -15 C to +46 C Operating Range Bulkhead Ducted Technical focus Market-leading Energy Efficiency Only 370mm Deep Easy Installation Built-in Drain Pump (200mm lift*) -15 C to +46 C Operating Range * Refer to Technical Documents for more details * Refer to Technical Documents for more details Ultra Slim Ducted Capacity 2.60KW 3.70KW 5.00KW Model Name Indoor Unit CS-E9SD3RW CS-E12SD3RW CS-E18SD3RW Outdoor Unit CU-E9SD3R CU-E12SD3R CU-E18SD3R Cooling capacity : Heating capacity kw BTU/h 2.6 ( ) 3.30 ( ) 8,870 (2,900-10,900) 11,300 (2,900-15,300) 3.70 ( ) 4.20 ( ) 12,600 (2,900-13,600) 14,300 (2,900-17,400) 5.00 ( ) 6.10 ( ) 17,100 (3,070-19,400) 20,800 (3,070-24,200) EER : COP W/W 4.19 : : : 3.59 Total power input Cooling : Heating kw 0.62 ( ) : 0.84 ( ) 1.03 ( ) : 1.10 ( ) 1.50 ( ) : 1.70 ( ) Indoor Unit Power source Phase/Hz 1 Phase/ 50Hz 1 Phase/ 50Hz 1 Phase/ 50Hz V 240V 240V 240V Current Cooling : Heating A 2.8 : : : 7.4 Dimensions H W D mm 200 x 750 x x 750 x x 750 x 640 Net weight kg Air volume Cooling : Heating L/s 231 : : : 293 External static pressure Pa Sound pressure level (H/M/L) Cooling : Heating db(a) 32 / 27 / 24 : 34 / 28 / / 27 / 24 : 35 / 28 / / 30 / 27 : 41 / 32 / 29 Sound power level (H/M/L) Cooling : Heating db(a) 48 / 43 / 40 : 50 / 44 / / 43 / 40 : 51 / 44 / / 46 / 43 : 57 / 48 / 45 Outdoor Unit Power source Phase/Hz 1 Phase / 50Hz 1 Phase / 50Hz 1 Phase / 50Hz V 240V 240V 240V Dimensions H W D mm 619 x 824 x x 824 x x 875 x 320 Net weight kg Piping connections Liquid / Gas m Ø6.35 (1/4) / Ø9.52 (3/8) Ø6.35 (1/4) / Ø12.70 (1/2) Ø6.35 (1/4) / Ø12.70 (1/2) Pipe length min. - max. m Elevation difference (OU located lower, OU located higher) m Operation ranges Cooling : Heating C 5-46 : : : * These products are not supported by PAC/VRF Smart Connectivity and Panasonic AC Smart Cloud. 34

35 Products for Small Sized Project CS-E9SD3RW CS-E12SD3RW CS-E18SD3RW CS-E9QD3RW CS-E12QD3RW CS-E18QD3RW CS-E9SB4RW CS-E12QB4RW CS-E18QB4RW Panel CZ-BT20E CU-E9SD3R/CU-E9QD3R/CU-E9SB4R CU-E12SD3R/CU-E12QD3R/CU-E12QB4R CU-E18SD3R/CU-E18QD3R/CU-E18QB4R CZ-RD52CP 4-Way Mini Cassette Technical focus Market-leading Energy Efficiency Compact Design (260mm High) Easy Installation Built-in Drain Pump (600mm lift*) -15 C to +46 C Operating Range * Refer to Technical Documents for more details Bulkhead Ducted Mini Cassette 2.50KW 3.40KW 5.00KW 2.50KW 3.40KW 4.80KW CS-E9QD3RW CS-E12QD3RW CS-E18QD3RW CS-E9SB4RW CS-E12QB4RW CS-E18QB4RW CU-E9QD3R CU-E12QD3R CU-E18QD3R CU-E9SB4R CU-E12QB4R CU-E18QB4R 2.50 ( ) 3.20 ( ) 8,530 (2,900-10,600) 10,900 (2,900-15,000) 3.40 ( ) 4.00 ( ) 11,600 (2,900-13,600) 13,600 (2,900-17,400) 5.00 ( ) 6.10 ( ) 17,100 (3,070-19,400) 20,800 (3,070-24,200) 2.50 ( ) 3.20 ( ) 8,530 (2,900-10,900) 10,900 (2,900-16,000) 3.40 ( ) 4.00 ( ) 11,600 (2,900-13,600) 13,600 (2,900-18,400) 4.80 ( ) 5.00 ( ) 16,400(3,070-19,400) 17,100 (3,070-20,400) 3.85 : : : : : : ( ) : 0.88 ( ) 0.95 ( ) : 1.18 ( ) 1.54 ( ) : 1.85 ( ) 0.55 ( ) : 0.78 ( ) 0.88 ( ) : 1.05 ( ) ) : 1.51 ( ) 1 Phase/ 50Hz 1 Phase/ 50Hz 1 Phase/ 50Hz 1 Phase/ 50Hz 1 Phase/ 50Hz 1 Phase/ 50Hz 240V 240V 240V 240V 240V 240V 3.0 : : : : : : x 750 x x 750 x x 750 x x 575 x x 575 x x 575 x : : : : : : / 27 / 24 : 34 / 28 / / 27 / 24 : 35 / 28 / / 30 / 27 : 42 / 32 / / 26 / 23 : 35 / 28 / / 26 / 23 : 37 / 28 / / 28 / 25 : 39 / 29 / / 43 / 40 : 50 / 44 / / 43 / 40 : 51 / 44 / / 46 / 43 : 48 / 48 / / 42 / 39 : 51 / 44 / / 42 / 39 : 53 / 44 / / 44 / 41 : 55 / 45 / 42 1 Phase / 50Hz 1 Phase / 50Hz 1 Phase / 50Hz 1 Phase / 50Hz 1 Phase / 50Hz 1 Phase / 50Hz 240V 240V 240V 240V 240V 240V 619 x 824 x x 824 x x 875 x x 824 x x 824 x x 875 x Ø6.35 (1/4) / Ø9.52 (3/8) Ø6.35 (1/4) / Ø12.70 (1/2) Ø6.35 (1/4) / Ø12.70 (1/2) Ø6.35 (1/4) / Ø9.52 (3/8) Ø6.35 (1/4) / Ø12.70 (1/2) Ø6.35 (1/4) / Ø12.70 (1/2) : : : : : :

36 OUTDOOR UNIT Dimensions (2.5kW 3.7kW) Dimensions (4.8kW 5.0kW) 36

37 Small Sized Project Dimensions ULTRA SLIM DUCTED Dimensions (2.5kW 5.0kW) <Front View> (AIR OUTLET DUCT FLANGE) 692 (AIR OUTLET DUCT FLANGE) 145 <Top View> 96 <Side View> <Side View> Ø 3.1 HOLE = Ø 3.1 HOLE WATER INLET DRAIN PORT (UPPER & LOWER) (AIR INLET) 126 AIR FILTER 680 (AIR INLET) <Back View> Unit: mm 37

38 BULKHEAD DUCTED Dimensions (2.5kW 3.4kW) Dimensions (5.0kW) 4-WAY MINI CASSETTE Dimensions (2.5kW 5.0kW) 38

39 Small Sized Project Dimensions 39

40 Smart Control Management Solutions Panasonic has developed the latest range of smart control management solutions offering streamlined approaches for each unique need. From individual remote control for residential split systems, up to the newest cloud based technology, allowing you to control each of your buildings around the world, all from your portable device. PAC/VRF Smart Connectivity Through thorough energy management, Panasonic s PAC/VRF Smart Connectivity is a completely new, state-of-the-art solution providing energy saving and comfort as well as simple installation, operating and running. 40

41 Smart Control Management Solutions Centralised Control System This integrated control system is ideal for largescale spaces, and achieves more ef cient operation. Individual Controllers A remote control solution to optimise the temperature in each room. With a simple click, all your units from several locations, receive status updates in real-time reducing the chance of breakdowns and optimising costs. 41

42 PAC/VRF Smart Connectivity Through thorough energy management, Panasonic s PAC/ VRF Smart Connectivity is a completely new, state-of-theart solution providing energy saving and comfort as well as simple installation, operation and running. PAC/VRF Smart Connectivity PAC/VRF Smart Connectivity offers ef nt energy management and a new air conditioning control solution with high IAQ. Energy Management System for Rooms Management System for the Entire Building Each room is monitored by high-precision sensors, making it possible to make every room s temperature comfortable without wasting energy. A Building Energy Management System (BEMS) can also be connected for Plug & Play centralised control of the building s entire energy consumption. Advantages Dramatic Reduction of OpEx with Outstanding IAQ. 3 Built-in sensors: Temperature, RH and Light (PIR Optional) ZigBee wireless sensors: CO2, window/ door, human presence. User-/Owner-friendly. Colour touch screen Ease and simply of use 20 Languages Easy-to-understand error description Ultimate Customisation. Background colour customisable Custom display/icons, messages Programmable logic (also stand alone) Easy Design and Plug and Play to Reduce CapEx. Simple Plug & Play PAC/VRF connection to Building Energy Management System (BEMS) Stand alone or BEMS connected Easy Installation of Zigbee Sensors 42

43 PAC/VRF Smart Connectivity Energy Management System for Rooms By installing a ceiling motion sensor, wall motion temperature sensor, window/door sensor, and CO2 sensor in the room, ideal, waste-free air conditioning is achieved. VRF OR PAC Wired Connection SER8150 Ceiling motion sensor Wall motion temperature sensor Window / Door sensor CO2 sensor Sensing Technology Using sensors from Schneider Electric, high-quality occupancy control and automatic IAQ control were realised. The sensors detect the presence or absence of occupants, and the opening and closing of doors and windows to achieve the most efficient energy management for exceptional air-conditioned comfort. Flexible installation is possible to match different applications and building features such as walls, ceilings and proximity to doors and windows. No wiring means extra installation versatility. Window sensor (option) Room controller Built in PIR, Humidity Ceiling motion sensor (option) Door sensor (Option) CO 2 sensor (option) Wall motion temperature sensor (option) Batteries last for up to five years and are easy to install and replace. SED-WMS-P-5045 Window / Door sensor SED-CMS-P-5045 Ceiling motion sensor SED-WMS-P-5045 Wall motion temperature sensor SED-CO2-G-5045 CO2 sensor * Specifications are subject to change. Built-in PIR Sensor Control Built-in occupancy sensors detect the presence or absence of people in each room for optimum control. This creates an environment of high productivity and efficiency. Humidity Sensor Control Humidity sensors enable automatic dehumidification for the optimum IAQ regardless of climatic conditions. * Except for products for small sized project (Ultra Slim Ducted, Bulkhead Ducted, 4-Way Mini Cassette) 43

44 Management System for the Entire Building The smarter solution to simplify energy management, Plug and Play BEMS connection. With the SER8150 connection to BEMS is extremely easy. Better still, a remote controller is all that s needed to enable use as a stand-alone system. In addition to dramatically reducing the burden on system integrators, this cuts costs. Panasonic PAC&VRF PAC VRF GHP A Ceiling motion Wall motion temp. sensor Room controller Window / Door sensor CO2 sensor Multi-purpose Manager (MPM) SEC-TE Smart Terminal Controller B A B SER8150 smart controller with direct hub to ZigBee Pro sensors. Great Occupancy and IAQ control. Ex: Hotel room occupancy check by PIR sensor, IAQ by CO2 sensor, Door / Window contacts. BACnet MS/TP or Modbus RTU direct connection can be assigned a device address by room scale. C * * Also available Modbus RTU. With VRF dedicated GUI BEMS Widget (Exclusive) C For Schneider Electric BEMS connection, Panasonic VRF widgets enable easy Plug and Play. * Graphic shows combination of products from Panasonic, Schneider Electric and others. Currently, some products might not available in Australia, please consult authorised dealer for more details. 44

45 PAC/VRF Smart Connectivity Smart Management Solutions 1 Hotels Room Key Cardless Solution with Programmable Controller The SER8150 and Zigbee Sensor automatic detection function offer optimal air conditioning regardless of whether there is a hotel room key or not. Sensors detect the presence or absence of occupants and the opening and closing of doors and windows for the optimum air-conditioned environment guests expect. Automatic control ensures the most ef ient operation when guests are away or when windows are open. This contributes to an appreciable reduction in operation costs. System Example 1. If a guest s presence is detected and the window is closed, the air-conditioner can be operated. 2. If the room is empty and RH is over 60%, dry mode is automatically selected. * System integration may be required. A truly comfortable experience for guests Easy-to-understand, re ned on-screen images enable display of hotel logos and original welcoming messages. Colour and design can also be customised for different facilities to create an even more comfortable environment for guests. 2 Small and Medium Of s 3 Super Markets CO2 sensors (option) and Humidity sensors CO2 sensors (option) take measurements in units of ppm, and humidity sensors enable e air quality control. This creates the most comfortable space for occupants while contributing to improved employee satisfaction. Humidity sensors Humidity sensors enable automatic dehumidi cation for the optimum IAQ regardless of climatic conditions. This creates an even more comfortable environment for customers, employees, and products themselves. * Except for products for small sized project (Ultra Slim Ducted, Bulkhead Ducted, 4-Way Mini Cassette) 45

46 Innovative and Unrivalled Advantages Colour and Design to Match Of Interiors Colour combinations and design can be set to match different facilities. Easy-to-Understand Error Description Error description during an emergency is easy to understand, enabling staff to respond quickly. Customisation in 20 Languages Possible The display can be customised to match the native languages of guests to enable smooth, stress-free communication for hospitality at its nest. *Currently 6. More languages scheduled for a late 2018 release. Programmable Logic Full customisation of remote control logic possible, and updating to match conditions. Smart Connectivity Devices SED-WDS-P-5045 Window / Door sensor SED-CMS-P-5045 Ceiling motion sensor Schneider Electric brand - SER8150 SED-WMS-P-5045 Wall motion temperature sensor SED-CO2-G-5045 CO 2 sensor Features Up to 5-year battery life, batteries included Battery level is a point Sensor points visible in SBO when SER8150 is integrated via BACnet MS/TP Sensor status and battery level visible in SBE when SER8150 is integrated via ZigBee Pro Integration to SBE only recommended when each MPM is connected to Ethernet and set as a ZigBee Coordinator node Remote Controller SER8150R0B1194 SER8150R5B1194 Interface VCM8000V5094P VCM8000R94BOX * VCM8000V5094G * Description Panasonic Net Con, RH, No PIR, R1/R2 (Wired) Panasonic Net Con, RH, PIR, R1/R2 (Wired) Description Panasonic wireless Zigbee Pro Com.card Panasonic R1/R2 (Wired) to Zigbee adaptor box No Brand Wireless Zigbee Pro / Green Com card 1. VCM8000V5094P : Required in case wired solution connecting with Zigbee Sensors. 2. VCM8000V5094G : Required in case wired solution need to do MPM connection. 3. As for the products marked with*, the time of release will be announced later. 4. are subject to change. Sensor SED-WMS-P-5045 SED-WDS-P-5045 SED-CMS-P-5045 SED-CO2-G-5045 * Fascia FAS-00 FAS-01 FAS-03 FAS-05 FAS-06 FAS-07 FAS-10 Description SED SEN OCC WALL ZP SED SW DOR/WIN ZP SED SEN OCC CEIL ZP Wireless Zigbee Green CO2 sensor Description Silver White Translucent White Light Tan Wood Brown Wood Dark Brown Wood Brushed Steel 46

47 PAC/VRF Smart Connectivity PAC/VRF Smart Connectivity controller external dimensions Room Controller SER Dimensions & Wiring & Specifications 6 120mm (4.72 ) 25mm (0.99 ) 86mm (3.37 ) R1R RS RS RS-485 REF BACnet MS/TP or Modbus Dimensions Height: 12cm/4.72in Width: 8.6cm/3.39in Depth: 2.7cm/1.06in Power Requirements 16 Vdc from Panasonic R-R IDU connectors 50/60 Hz, 4VA, Class 2 Supply Range from Indoor Unit Recommended 500ft (150 m) Operating Conditions 0 C to 50 C (32 F to122 F) 0% to 95% R.H. non-condensing Storage Conditions -30 C to 50 C (-22 F to 122 F) 0% to 95% R.H. non-condensing Temperature Sensor Local 10 K NTC type 2 thermistor Temperature Sensor Resolution ± 0.1 C (± 0.2 F) Temperature Sensor Accuracy ± 0.5 C (± 0.9 F 21 C (70 F) typical calibrated Humidity Sensor and Calibration Single point calibrated bulk polymer type sensor Humidity Sensor Precision Reading range from 10 to 90 % R.H. noncondensing 10 to 20% precision: 10% 20% to 80% precision: 5% 80% to 90% precision: 10% Humidity Sensor Stability Less than 1.0 % yearly (typical drift) Wiring Maximum wire length between last indoor unit to SER8150RxB1194 equals 490ft (150m) with AWG #18 wire (0.82 mm 2 ). Refer to Panasonic VRF guidelines Wiring System Diagram for Remote Controller for this limitation. Approximate Shipping Weight 0.34 kg (0.75 lb) Safety Standards All Models LVD Directive 2006/95/EC EN :2006/A2:2013 UL 873 CSA C22.2 No EMC Standards All Models EMC Directive 2004/108/EC IEC :2005 FCC 15 Subpart B ICES-003 Radio Standards (Wireless Models) R&TTE Directive 1999/5/EC IEC :2005 EN V1.9.2 EN V1.8.1 FCC 15 Subpart C, Class A RSS 210 THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFER - ENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. Check with your local government for instruction on disposal of these products. Ceiling Motion Sensor SED-CMS-P Dimensions & Wiring & Specifications 0 Dimensions 65mm H x 29mm W x 25mm D (2.56in H x 1.14in W x 0.99in D) Color White Weight 30g (1.06oz) with battery Dimensions 75mm diameter x 20mm thick (2.94in diameter x 0.75in thick) Colour White Dimensions Weight 75mm diameter 50g (1.8oz) x 20mm with batteries thick (2.94in diameter x 0.75in thick) Colour White Weight Communication 50g (1.8oz) ZigBee, with HA1.2 batteries Compatible Communication Range Up to 40ft (12m), open field 300ft (100m) Communication Detection Range Communication Range ZigBee, Maximum: HA1.2 Compatible 90 deg cone, 16.5ft (5m) Up to 40ft Recommended: (12m), open field 45 deg, 300ft 12ft (100m) (3.6m) Detection Range Maximum: 90 deg cone, 16.5ft (5m) 3 Battery Voltage Recommended: 1.5VDC Alkaline 45 deg, 12ft (3.6m) Battery Cell 2 x AAA (recommended Panasonic LR03XWA) Battery Battery Voltage Life 1.5VDC Up Alkaline to 5 years Battery Ambient Cell Temperature 2 x AAA -10 (recommended o C to +50 o C Panasonic (+14 o F to LR03XWA) +122 o F) Battery Life Up to 5 years Ambient Temperature -10 o C to +50 o C (+14 o F to +122 o F) Certification Certification Check with your local government for instruction on disposal of these products. Check with your local government for instruction on disposal of these products. Communication ZigBee, HA1.2 Compatible Communication Range Up to 40ft (12m) open field 300ft (100m) Detection Range Maximum: 90 deg cone, 16.5ft (5m) Recommended: 47 deg, 16ft (5m) Certification 3 Battery Voltage 3.0VDC Lithium Battery Cell CR2 (recommended Panasonic CR15H270) Check with your local government for Wall Battery Motion Life Sensor Up to 5 years SED-WMS-P Dimensions & Wiring & Specifications instruction on disposal of these products. Ambient Temperature -10 o C to +50 o C (+14 o F to +122 o F) Dimensions 65mm H x 29mm W x 25mm D (2.56in H x 1.14in W x 0.99in D) Color White Weight 30g (1.06oz) with battery Communication ZigBee, HA1.2 Compatible Communication Range Up to 40ft (12m) open field 300ft (100m) Detection Range Maximum: 90 deg cone, 16.5ft (5m) Recommended: 47 deg, 16ft (5m) Certification 3 Battery Voltage 3.0VDC Lithium Battery Cell CR2 (recommended Panasonic CR15H270) Battery Life Up to 5 years Ambient Temperature -10 o C to +50 o C (+14 o F to +122 o F) Check with your local government for instruction on disposal of these products. Sensor Dimensions 32mm wide x 30mm high x 11mm thick (1.26in wide x 1.16in high x 0.43in thick) Magnet Dimensions 15mm wide x 32mm high x 6mm thick (0.59 wide x 1.26 high x 0.24 thick) Color White Weight 11g (0.38oz) with battery Communication ZigBee, HA1.2 Compatible Communication Range Up to 40ft (12m) open field 300ft (100m) Certification Battery Voltage 3.0VDC Lithium Door/Window Battery Cell CR2032 (recommended Contact Panasonic CR2032) SED-WDS-P-5045 Check with your local government for - Dimensions & Wiring & Specifications Battery Life Up to 5 years Ambient Temperature -10 o C to +50 o C (+14 o F to +122 o F) instruction on disposal of these products. 3 Sensor Dimensions 32mm wide x 30mm high x 11mm thick (1.26in wide x 1.16in high x 0.43in thick) Magnet Dimensions 15mm wide x 32mm high x 6mm thick (0.59 wide x 1.26 high x 0.24 thick) Color White Weight 11g (0.38oz) with battery Communication ZigBee, HA1.2 Compatible Communication Range Up to 40ft (12m) open field 300ft (100m) Certification Battery Voltage 3.0VDC Lithium Battery Cell CR2032 (recommended Panasonic CR2032) Battery Life Up to 5 years Ambient Temperature -10 o C to +50 o C (+14 o F to +122 o F) Check with your local government for instruction on disposal of these products. *Except for products for small sized project (Ultra Slim Ducted, Bulkhead Ducted, 4-way Mini Cassette) 47

48 Panasonic AC Smart Cloud The new Panasonic AC Smart Cloud system allows you to have complete control of all your installations. With a simple click, all your units from several locations, receive status updates in real-time reducing the chance of breakdowns and optimising costs. What is AC Smart Cloud? Using a cloud computing system, AC Smart Cloud lets you monitor and manage the energy consumption of multiple locations from anywhere, anytime. Site A AC Smart Cloud Site B Site C AC Smart Cloud is suitable for various facilities Retail School Hotel Hospital 48

49 Panasonic AC Smart Cloud Flexible and Scalable Solution Energy monitoring Anytime, Anywhere Site(s) management Centralise control of your business premises, from wherever you are, 24/7/365. It doesn t matter how many sites you have, or where they are! The AC Smart Cloud system from Panasonic allows you to have complete control of all your installations, from your tablet or your computer. In a simple click, receive status updates in real-time of all your installations, preventing breakdowns and optimising costs. Anytime Small to large Flexible solution for your business. Anywhere 1 to multi sites Multi-platform Scalable solution for your business. Upgrade features* Internet browser Multi PAC/VRF * Customised to meet user demand / Upgraded new functions / Upgraded by new products / IT smart management. Key Functions and Uniqueness Multi site monitoring. It doesn t matter how many sites you have, easy to manage, operate, compare per sites, locations, rooms. Powerful statistics for energy savings. Power consumption, capacity, ef y level can be compared according to variable parameters (Yearly / monthly / weekly/ daily bases) Schedule setting. Weekly / holiday timer setting as you want One setting can be copied to other sites Maintenance noti cation. Error ion by and with r layout Maintenance of PAC / VRF outdoor units User customisation. Site administrator can create users as desired and assign customised pro es. Facility manager: A Energy optimisation Multisite monitoring Schedule management Maintenance noti cation Owner of Hotels Administrator has a full access Facility manager: B Energy optimisation Multisite monitoring Schedule management Maintenance noti cation Facility manager: C Energy optimisation Multisite monitoring Schedule management Maintenance noti cation 3 Steps to Set Up AC Smart Cloud Panasonic AC Smart Cloud is very easy to install on existing and new installations. The communication adaptor (CZ-CFUSCC1) is connected to the Panasonic bus and the Ethernet. Then in only 3 steps, the cloud system is running. * Except for products for small sized project (Ultra Slim Ducted, Bulkhead Ducted, 4-Way Mini Cassette) 49

50 Controllers A wide variety of control options to meet the requirements of different applications. OPERATION SYSTEM INDIVIDUAL CONTROL SYSTEMS Requirements High-spec operation Normal operation Operation from anywhere in the room External appearance Deluxe Wired Remote Controller Timer Remote Controller (Wired) Wireless Remote Controller Type, model name CZ-RTC5B CZ-RTC4 CZ-RWSU3 CZ-RWST3N CZ-RWSK2 + CZ-RWSC3 Built-in thermostat ECONAVI on/off control Number of indoor units which can be controlled 1 group, 8 units 1 group, 8 units 1 group, 8 units Up to 2 controllers can be connected per group (When Up to 2 controllers can be connected per group. Up to 2 controllers can be connected per group. Use limitations using ECONAVI sensor, only one remote controller is possible to connect at indoor unit) (When using ECONAVI sensor, only one remote controller is possible to connect at indoor unit) Function ON/OFF Mode setting Fan speed setting Temperature setting Air direction Permit/Prohibit switching Weekly program 1. Setting is not possible when a remote control unit is present. (Use the remote controller for setting.) All subject to change without notice. 50

51 Controllers CENTRALISED CONTROL SYSTEMS Normal operation Operation with various function from centre station Only ON/OFF operation from centre station load distribution ratio (LDR) for each tenant Touch screen panel Connection with 3rd Party Controller Seri-Para I/O unit for outdoor unit CZ-CAPDC2 Wired Remote Controller System Controller ON/OFF Controller Intelligent Controller Interface adaptor CZ-RD52CP CZ-64ESMC3 CZ-ANC3 CZ-256ESMC3 (CZ-CFUNC2) CZ-CAPC3 Seri-Para I/O unit for each indoor unit 1 64 groups, max. 64 units 16 groups, max. 64 units 64 units x 4 links, max. 256 units CZ-CAPBC2 Only 1 controller for 1 Up to 10 controllers, can be indoor unit. connected to one system. Main unit/sub unit (1 main unit + 1 sub unit) connection is possible. Use without remote controller is possible. Up to 8 controllers (4 main units + 4 sub units) can be connected to one system. Use without remote controller is impossible. A communication adaptor (CZ-CFUNC2) must be installed for three or more links. Communication Adaptor CZ-CFUNC2 LonWorks Interface CZ-CLNC2 ¹ ¹ 51

52 Individual Control Systems Control contents Part name, model No. Quantity Standard Control Control of the various operations of the indoor unit by wired or wireless remote controller. Cooling or heating mode of the outdoor unit is decided by the priority of the remote controller. Switching between remote controller sensor and body sensor is possible. Wired remoted controller CZ-RTC4 / CZ-RTC5B Wireless remote controller CZ-RWSU3 / CZ-RWST3N / CZ-RWSK2 + CZ-RWSC3 1 unit each (1) Group control Batch remote control on all indoor units. Operation of all indoor cells in the same mode. Up to 8 units can be connected. The sensor is the body sensor, and thermostat ON/OFF setting in regard to the temperature set by the remote controller is possible for each indoor unit. Wired remoted controller CZ-RTC4 / CZ-RTC5B Wireless remote controller CZ-RWSU3 / CZ-RWST3N / CZ-RWSK2 + CZ-RWSC3 As required (2) Main/sub remote control Max 2 remote controllers per indoor unit. (Main remote controller can be connected) The button pressed last has priority. Timer setting is possible even with the sub remote controller. When using ECONAVI sensor, only one remote controller is possible to connect at indoor unit. Main or sub Wired remoted controller CZ-RTC4 / CZ-RTC5B Wireless remote controller CZ-RWSU3 / CZ-RWST3N / CZ-RWSK2 + CZ-RWSC3 As required SYSTEM EXAMPLE Remote controller Main Sub Main Sub Standard control (2) Main/sub remote control (1) Group control 52

53 Controllers Deluxe wired remote controller (CZ-RTC5B) Energy Saving ECONAVI on/ off* Temperature Auto Return Temperature Setting Range Auto Shutoff Schedule peak cut Repeat off timer Dimensions H 120 x W 120 x D 16 mm Backup control by using CZ-RTC5B Group wiring of 2 systems of PAC can do auto individual control Rotation operation Backup operation Support operation Basic Operation Individual Louver Control (Lock individual ap for 4-way cassette) ON/ OFF timer Weekly Timer Filter information* Outing function Quiet operation mode* Power consumption monitor* Energy saving* Initial settings Ventilation Maintenance Function Outdoor unit error data Service Contact address RC setting mode Test Run Sensor Information* Service check Simple/ Detailed Settings Auto address * Subject to the connected model Timer remote controller (CZ-RTC4) Weekly Programme Function A maximum of 6 settings/day and 42 settings/week can be programmed. Outing Function This function can prevent the room temperature from dropping or rising when the occupants are out for a long time. Dimensions H 120 x W 120 x D 20 mm Basic remote controller ON/OFF Operation mode changeover (Cooling, Heating, Dry, Auto, Fan). Temperature setting (Cooling/Dry: 18-30º Heating: 16-30º). Fan speed setting H/ M/ L and Auto. Air w direction adjustment. ECONAVI on/ off* Sleeping Function This function controls the room temperature for comfortable sleeping. Maximum 8 indoor units can be controlled from one remote controller Remote control by main remote controller and sub controller is possible Maximum 2 remote controllers (main remote controller and sub controller) can be installed for one indoor unit. * Depending on the model, some menus cannot be used. Time Function 24 hours real time clock Day of the week indicator. 53

54 Wireless remote controller Remote control by main remote controller and sub controller is possible Maximum 2 remote controllers (main remote controller and sub controller) can be installed for one indoor unit. For 4-Way cassette type CZ-RWSU3 When CZ-RWSC3+CZ-RWSK2 is used, wireless control becomes possible for all indoor units When a separate receiver is set up in a different room, control from that room also becomes possible. Automatic operation by means of the emergency operation button is possible even when the remote controller has been lost or the batteries have been exhausted. In addition, there are other functions such as temperature setting, operation switching, wind direction/fan speed setting, etc For all Ducted types CZ-RWSC3 +CZ-RWSK2 Ventilation independent operation is possible When commercial ventilation fans or heat-exchange ventilation fans have been installed, they can be operated with this remote control (interlocked operation with the indoor unit or independent ventilation ON/OFF). For under ceiling type CZ-RWST3N Wired remote controller (CZ-RD52CP) 54

55 Controllers T10 Terminal for External Control (Digital Connection) Connecting an indoor unit to an external device is easy. The T10 Terminal featured in the electronic circuit board of all indoor units enables digital connection to external devices. (T10:CN061 at indoor unit PCB) Control items 1-2 (pulse input) : 1. Start/stop input 2. Remote controller prohibit input 3. Start signal output 4. Alarm signal output 300msec. or more Example of wiring T10 (yellow) COM COM V (output) Unit condition O N +12 OFF NOTE: The wire length from indoor unit to the Relay must be within 2.0m. Pulse signal changeable to static with JP cutting. (Refer to JP001) ON Condition (Pulse input): Unit ON/OFF condition switching with a pulse signal. (1 pulse signal: shortage status more than 300msec.or more) (Static input): Open/ Operation with Remote is permitted.(normal condition) Close/ Remote controller is prohibited (Static output): 12V output during the unit ON. / No output at OFF (Static output): 12V output when some errors occur / No output at normal. 2. Usage Example Forced OFF control Condition 1-2 (Static input): Close/ Operation with Remote is permitted. (Normal condition) Open/ Unit is forcibly OFF and Remote controller operation is prohibited. Example of wiring T10 (YEL) Indoor unit control PCB Relay (Field supply) POWER External contact (Card switch box, etc.: field supply) The contact in the figure is a state where the card is pulled out. NOTE: The wire length from indoor unit to the Relay must be within 2.0m Operation ON/OFF signal output Condition 4-5 (Static output): 12V output during the unit ON / No output at OFF Example of wiring T10 (YEL) Indoor unit control PCB Relay (Field supply) 2 m Central control NOTE: The wire length from indoor unit to the Relay must be within 2.0m Pulse signal changeable to static with JP cutting. (Refer to JP001) 55

56 Providing outstanding energy-saving performance, Panasonic s large capacity air conditioners can be connected to ECONAVI to detect when energy is being wasted. ECONAVI senses the presence or absence of people and the level of activity in each area of a room. When unnecessary heating or cooling is detected, indoor units are individually controlled to match room conditions for energy-saving operation. 4-way Cassette Under Ceiling Mid Static Duct ECONAVI Sensor CZ-CENSC1 Applicable to all 5-types of indoor units* * Except kW models High Static Duct Wall Mounted How 2 sensors work for human detection Detection of the level of activity enables optimum power saving Presence or absence of people and the level of activity in the room are detected in real time. Set temperature is automatically adjusted to optimise the power consumption. Case study at coffee shop In the morning Reduced cooling when there are fewer people. Sensors are remotely located to maximise the energysaving effect When sensors are built into the indoor unit, pillars, walls, cabinets and other can obstruct the sensors, reducing the area of detection and lowering the energy-saving effect. Panasonic sensors can be located any where in the room which enables the optimum layout for sensors in any location. Wide detection area In the afternoon Thorough cooling when there is a high level of activity. At night Automatic Thermo Off depending on conditions at the end of the day. A sensor is remotely set to maximise the detection area. Installation flexibility for indoor unit layout changes. 56

57 Controllers Remote Controller External Dimensions DELUXE WIRED REMOTE CONTROLLER (CZ-RTC5B) TIMER REMOTE CONTROLLER (CZ-RTC4) WIRELESS REMOTE CONTROLLER SEPARATE RECEIVER FOR WIRELESS REMOTE CONTROLLER (CZ-RWSC3) REMOTE SENSOR (CZ-CSRC3) ECONAVI SENSOR (CZ-CENSC1) Unit: mm SYSTEM CONTROLLER (CZ-64ESMC3) System Controller Switch Box R mm mm 57

58 Remote Controller External Dimensions COMMUNICATION ADAPTOR (CZ-CFUNC2) INTELLIGENT CONTROLLER (CZ-256ESMC3) Power indicator Illuminates at power-on R ø (mm) 8 R 5 Storage door Push lightly to open or close USB terminal (mm) ON/OFF CONTROLLER (CZ-ANC3) 116 SERI-PARA I/O UNIT FOR EACH INDOOR UNIT (CZ-CAPBC2) (6) (6) LONWORKS INTERFACE (CZ-CLNC2) SERI-PARA I /O UNIT FOR OUTDOOR UNIT (CZ-CAPDC2) 4 - Ø 5 hole Potbellied hole (4 locations) 3 - Ø 30 hole Detail of the potbellied hole Magnified view WIRED REMOTE CONTROLLER FOR RESIDENTIAL MODEL (CZ-RD52CP) 58

59

RESIDENTIAL & LIGHT COMMERCIAL AIR CONDITIONERS 2015 / 2016 EVERY BUILDING MATTERS

RESIDENTIAL & LIGHT COMMERCIAL AIR CONDITIONERS 2015 / 2016 EVERY BUILDING MATTERS RESIDENTIAL & LIGHT COMMERCIAL AIR CONDITIONERS 2015 / 2016 EVERY BUILDING MATTERS A Better Life, A Better World As we move towards our Centenary in 2018, our new brand slogan encapsulates Panasonic s

More information

PREMIUM INVERTER DUCTED AIR CONDITIONING

PREMIUM INVERTER DUCTED AIR CONDITIONING PREMIUM INVERTER DUCTED AIR CONDITIONING PANASONIC LEADS THE WAY Ducted Air Conditioning Specialists With more than 30 years of experience, exporting to more than 120 countries around the world, Panasonic

More information

DUCTED AIR CONDITIONING YEAR ROUND COMFORT FOR YOUR HOME

DUCTED AIR CONDITIONING YEAR ROUND COMFORT FOR YOUR HOME DUCTED AIR CONDITIONING YEAR ROUND COMFORT FOR YOUR HOME PANASONIC LEADS THE WAY Ducted Air Conditioning Specialists With more than 30 years of experience, exporting to more than 120 countries around the

More information

LARGE CAPACITY AIR CONDITIONERS 2012 / EVERy BUILDING MATTERS

LARGE CAPACITY AIR CONDITIONERS 2012 / EVERy BUILDING MATTERS LARGE CAPACITY AIR CONDITIONERS 2012 / 2013 EVERy BUILDING MATTERS Panasonic Air Conditioning Designed To Care For Your Projects With more than 30 years of experience, exporting to more than 120 countries

More information

M1 TYPE SLIM VARIABLE STATIC PRESSURE HIDE AWAY CONCEALED DUCT

M1 TYPE SLIM VARIABLE STATIC PRESSURE HIDE AWAY CONCEALED DUCT VRF SYSTEMS M TYPE SIM VARIABE STATIC PRESSURE IDE AWAY CONCEAED DUCT The ultra slim M type is one of the leading products of its type in the industry. With a depth of only mm it provides greater flexibility

More information

WELCOME TO THE COMMERCIAL RANGE. NEW PACi TECHNOLOGY

WELCOME TO THE COMMERCIAL RANGE. NEW PACi TECHNOLOGY WELCOME TO THE COMMERCIAL RANGE NEW PACi TECHNOLOGY 128 NEW / COMMERCIAL Here are some of your new air conditioner s major features. Panasonic has developed an impressive range of highly efficient Commercial

More information

DUCTED AIR CONDITIONING YEAR ROUND COMFORT FOR YOUR HOME

DUCTED AIR CONDITIONING YEAR ROUND COMFORT FOR YOUR HOME CONDITIONING YEAR ROUND COMFORT FOR YOUR HOME Ducted Air Conditioning Specialists With ore than 0 years of experience, exporting to ore than 120 countries around the world, Panasonic is unquestionably

More information

COMMERCIAL // HEATING AND COOLING SYSTEMS EVERY OFFICE MATTERS

COMMERCIAL // HEATING AND COOLING SYSTEMS EVERY OFFICE MATTERS 2010 COMMERCIAL // HEATING AND COOLING SYSTEMS EVERY OFFICE MATTERS COMMERCIAL WELCOME TO COMMERCIAL RANGE Welcome to Commercial range. Welcome to healthier air. A range which confi rms its commitment

More information

INVERTER DUCTED SYSTEMS

INVERTER DUCTED SYSTEMS INVERTER DUCTED SYSTEMS What you ll find inside: DC Twin-Rotary Compressor Inverter Ducted advantages Controllers Product specifications Energy Efficient Powerful Operation Flexible Application 1 About

More information

Hitachi Multizone Heat Pump Air Conditioning

Hitachi Multizone Heat Pump Air Conditioning Cooling 1.5 13.2 Heating 1.5 14.4 Hitachi Heat Pump Air Conditioning Giving you complete control Zone control that s fast, efficient and clean Imagine being able to rapidly adjust the comfort levels in

More information

DC INVERTER VRF SYSTEMS C-VRF

DC INVERTER VRF SYSTEMS C-VRF DC INVERTER VRF SYSTEMS C-VRF Index VRF System Overview 4 C-VRF 9 Advantages 10 Benefits For Users 14 Benefits For Installers 18 C-VRF MINI 27 Advantages 28 Indoor Units 33 Indoor Units Line Up 34 Indoor

More information

DC INVERTER DUCTED AIR CONDITIONERS

DC INVERTER DUCTED AIR CONDITIONERS DC INVERTER DUCTED AIR CONDITIONERS DC Inverter Ducted Air Conditioners Technology. With over 5% of revenue invested in research and development programs, Hitachi has developed world leading technologies

More information

R410A TECHNICAL MANUAL. Inverter Single Split Series Air Conditioner. FTK-J, FTXN-J Series. Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2

R410A TECHNICAL MANUAL. Inverter Single Split Series Air Conditioner. FTK-J, FTXN-J Series. Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2 R410A TECHNICAL MANUAL Inverter Single Split Series Air Conditioner FTK-J, FTXN-J Series Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2 Table of Contents Table of Contents Nomenclature...1 Indoor...1 Outdoor...1

More information

VRF. For Commercial and Light Commercial

VRF. For Commercial and Light Commercial 118 VRF For Commercial and Light Commercial 119 SOLUTIONS SMALL OFFICES Fujitsu General provides perfect total air conditioning systems that take into account energy saving, low noise, comfortable airflow,

More information

Residential range. When technology meets comfort

Residential range. When technology meets comfort Residential range When technology meets comfort Index Inverter technology 4 Indoor air quality 6 Design and control 8 Matching tables 10 Super Daiseikai 11 Suzumi 12 GKHP Fixed speed indoor units 13 Multi-split

More information

FULL DC INVERTER SYSTEMS INDIVIDUAL AND MODULAR CONSTRUCTION FLEXIBLE COMBINATIONS AIR CONDITIONING COMMERCIAL AIR CONDITIONERS SDV4 2014

FULL DC INVERTER SYSTEMS INDIVIDUAL AND MODULAR CONSTRUCTION FLEXIBLE COMBINATIONS AIR CONDITIONING COMMERCIAL AIR CONDITIONERS SDV4 2014 FULL DC INVERTER SYSTEMS INDIDUAL AND MODULAR CONSTRUCTION FLEXIBLE COMBINATIONS COMMERCIAL AIR CONDITIONERS SDV4 2014 AIR CONDITIONING 1 WELCOME TO THE WORLD OF SINCLAIR AIR CONDITIONERS Company operation

More information

Product Catalog. Variable Refrigerant Flow (VRF) VRF-PRC026A-EN. Mid-Static Concealed (Ducted) Indoor Units. November 2015

Product Catalog. Variable Refrigerant Flow (VRF) VRF-PRC026A-EN. Mid-Static Concealed (Ducted) Indoor Units. November 2015 Product Catalog Variable Refrigerant Flow (VRF) Mid-Static Concealed (Ducted) Indoor Units Indoor Unit Model number: 4TVD****C***** November 2015 VRF-PRC026A-EN Introduction Trane variable refrigerant

More information

Multi-Split Air Conditioners 2016/2017

Multi-Split Air Conditioners 2016/2017 Multi-Split Air Conditioners 2016/2017 Do not add replace refrigerant other than the specified type. Manufacturer is not responsible f the damage and deteriation in safety due to usage of other refrigerant.

More information

40KQV. Direct expansion split system Inverter Cassette. Nominal Cooling capacity: 4,85-12,40 kw Nominal Heating capacity: 5,10-13,00 kw

40KQV. Direct expansion split system Inverter Cassette. Nominal Cooling capacity: 4,85-12,40 kw Nominal Heating capacity: 5,10-13,00 kw LLOYD'S REGISTER QUALITY ASSURANCE Direct expansion split system Inverter Cassette I S O 9 00 1 40KQV Nominal Cooling capacity: 4,85-12,40 kw Nominal Heating capacity: 5,10-13,00 kw 40KQV cassette belongs

More information

modular multi intelligent, environmental and versatile

modular multi intelligent, environmental and versatile modular multi intelligent, environmental and versatile system overview 2-pipe R407C heat pump VRF system From 8 to 46 HP in one piping system (19 steps) Active leak detection system option Up to 40 indoor

More information

Midea VRFs/ Midea V5X. Timothy Huang Senior Engineer

Midea VRFs/ Midea V5X. Timothy Huang Senior Engineer Midea VRFs/ Midea V5X Timothy Huang Senior Engineer VRF Product Overview General Features V5X Key Technologies V5X VRF product strategy VRF line-up Fresh air solutions Selection software Unique Innovations

More information

AIR CONDITIONING SYSTEMS. Debuting the New Multi System MXZ-5A100VA. Maximum comfort for 5 rooms, using 1 outdoor unit

AIR CONDITIONING SYSTEMS. Debuting the New Multi System MXZ-5A100VA. Maximum comfort for 5 rooms, using 1 outdoor unit AIR CONDITIONING SYSTEMS Debuting the New Multi System Maximum comfort for 5 rooms, using 1 outdoor unit Debut of the New Multi System Built to Serve up to Five Rooms in All! N e w One Outdoor Unit Handling

More information

Hitachi Inverter Wall Split Air Conditioning

Hitachi Inverter Wall Split Air Conditioning Cooling Capacity 2.5kW - 8.0kW Heating Capacity 3.2kW - 9.0kW Hitachi Air Conditioning Giving you complete control Water-cooled Units Hitachi and Temperzone: Combining to offer Australia and New Zealand

More information

Now there s a sleek new profile in heat pumps

Now there s a sleek new profile in heat pumps New RELEASE Now there s a sleek new profile in heat pumps The Mitsubishi Electric Designer Series has been awarded the if Product Design award for its simple and elegant design. The clean, flat surfaces

More information

LG MULTI SPLIT SYSTEM

LG MULTI SPLIT SYSTEM 50Hz LG MULTI SPLIT SYSTEM Unlike traditional multitype units, it is a nextgeneration multitype airconditioner designed to be installed under any circumstance. LG Multi Split System Why? LG Multi World

More information

Indoor Console. Slim Design This is only 199mm thick, the slimmest on the market. Its slim design easily integrates the unit into your décor.

Indoor Console. Slim Design This is only 199mm thick, the slimmest on the market. Its slim design easily integrates the unit into your décor. Indoor Console Slim Design This is only 199mm thick, the slimmest on the market. Its slim design easily integrates the unit into your décor. Black Display Functional art, the touch screen display is elegant

More information

MSP Duct S Specifications

MSP Duct S Specifications MSP Duct S Specifications Model Name AM022FNMDEH AM028FNMDEH AM036HNMPKH AM045HNMPKH AM056HNMPKH Capacity *2) 2.2 2.8 3.6 4.5 5.6 *3) 2.5 3.2 4.0 5.0 6.3 Perfomance (Total) *5) kw 1.8 2.3 2.9 3.7 4.6 VRF

More information

LG Multi Split Air Conditioners

LG Multi Split Air Conditioners AUS-MUF111 New South Wales / Head Office 2 Wonderland Drive EASTERN CREEK NSW 266 PH : 02-8805-4000 FAX : 02-8805- Queensland 23 Terrace Place MURARRIE QLD 4 PH : 0-8-000 FAX : 0--41 Victoria 3 John Deere

More information

PRICE LIST

PRICE LIST PRICE LIST 2014-2015 100% PRODUCTION 100% PANASONIC TESTING AND QUALITY ASSURANCE RESEARCH & DEVELOPMENT AND DESIGN SERVICE PROVIDER PRO Club: the professional website of Panasonic Panasonic has an impressive

More information

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432K VRF HEAT PUMP

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432K VRF HEAT PUMP VEP075N432K Job Name: Location: Schedule No.: System Designation: Engineer: Architect: Date: For: Reference Approval Review Construction FEATURES Two-pipe heat pump Hinged electrical box for ease of maintenance

More information

Hi-Wall Inverter Split System. Cooling and heating, exactly where and when you need it

Hi-Wall Inverter Split System. Cooling and heating, exactly where and when you need it Hi-Wall Inverter Split System Cooling and heating, exactly where and when you need it Save on Running Costs 2.6kW & 3.2kW 4.2kW & 5.0kW 7.0kW & 8.0kW High Efficiency Along with running cost savings due

More information

Product Brochure 2018

Product Brochure 2018 Product Brochure 2018 2018 Brand Story - 2 - HEALTH Air Filter COMFORT Auto mode heating or cooling. and other materials. Wi-Fi Control Compatible to the Internet Evaporator self-cleaning ENERGY DRED Soft

More information

Ductless. MRV-S (Mini VRF) Product Brochure. Higher Comfort, Haier Living. rev 01/01/2018

Ductless. MRV-S (Mini VRF) Product Brochure. Higher Comfort, Haier Living. rev 01/01/2018 Higher Comfort, Haier Living 2018 MRV-S (Mini VRF) Product Brochure rev 01012018 Ductless HAIER MRV MILESTONES MRV-S KEY FEATURES Haier is one of the leading producers of HVAC products, having the capacity

More information

ceiling wall AWYZ14LB/18LB With the world's first self-cleaning filter system

ceiling wall AWYZ14LB/18LB With the world's first self-cleaning filter system ceiling wall Large and wide airflow High efficiency Low noise Large centre display Easy maintenance Inverter options Automatic filter cleaning options Easy-to-use remote controller AWYZ14LB/18LB With the

More information

SINGLE. Technical Data Book. Big Duct for Europe (R410A, 50Hz, H/P) Model : AC180JNHPKH/EU AC180JXAPNH/EU AC200JNHPKH/EU AC200JXAPNH/EU

SINGLE. Technical Data Book. Big Duct for Europe (R410A, 50Hz, H/P) Model : AC180JNHPKH/EU AC180JXAPNH/EU AC200JNHPKH/EU AC200JXAPNH/EU SINGLE Technical Data Book Big Duct for Europe (R410A, 50Hz, H/P) Model : AC180JNHPKH/EU AC180JXAPNH/EU AC200JNHPKH/EU AC200JXAPNH/EU History Version Modification Date Remark Ver.1.0 Release SINGLE Big

More information

MULTI SPLIT SYSTEM AIR CONDITIONERS

MULTI SPLIT SYSTEM AIR CONDITIONERS MULTI SPLIT SYSTEM AIR CONDITIONERS Come home to comfort with LG The Total HVAC and Energy Solution Provider Ever since manufacturing orea s first homegrown air conditioner in 1968, L has remained at the

More information

Ductless Split Systems

Ductless Split Systems Ductless Split s Right Product for the Right Application September 2014 Ductless Split s Right Product for the Right Application Single-Zone s Multi-Zone s (up to five rooms) High Wall High Wall, Cassette,

More information

Technical Service Manual

Technical Service Manual Technical Service Manual 60 Hz Low/Mid Pressure Duct Units 7 48 MBH Units 96 MBH Unit June 2009 VRF-SVM21A-EN Low and Mid Pressure Duct Units 1. Features......... 2 2. Specifications......... 3 3. Dimensions.........

More information

Hitachi Inverter Wall Split Air Conditioning

Hitachi Inverter Wall Split Air Conditioning Cooling Capacity 2.5kW - 8.0kW Heating Capacity 3.2kW - 9.0kW Hitachi Inverter Wall Split Air Conditioning Giving you complete control Water-cooled Units Hitachi and Temperzone: Combining to offer Australia

More information

ISO E5

ISO E5 R410 2013 13P01E Line up Hyper Inverter 1.5 2 2.5 3 4 5 6 8 10 - - HP Our new advanced technology has realized high efficiency, strong heating and long piping. This contributes to the environmental protection

More information

Four-Way Ceiling Cassette

Four-Way Ceiling Cassette Benefits of Multi F Systems Individual zone control Operating ranges of 14 F to 118 F in cooling and 0 F to 64 F in heating Quiet and comfortable environment Safer and easier installation with Cost efficient

More information

New ECOi Electric 2 and 3 pipe VRF systems. 2006/7 Range. All round air conditioning by

New ECOi Electric 2 and 3 pipe VRF systems. 2006/7 Range. All round air conditioning by New ECOi Electric 2 and 3 pipe VRF systems 2006/7 Range 1 All round air conditioning by ECOi the next generation of 2 and 3 pipe electric SANYO is justifi ably proud of being renowned for developing unique

More information

Hitachi Inverter Wall Split Air Conditioning

Hitachi Inverter Wall Split Air Conditioning Cooling Capacity 2.5kW - 8.0kW Heating Capacity 3.2kW - 9.0kW Hitachi Inverter Wall Split Air Conditioning Giving you complete control Water-cooled Units Hitachi and Temperzone: Combining to offer New

More information

42GW. Hydronic Cassette Fan Coil Units PRODUCT SELECTION DATA INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS EASY INSTALLATION

42GW. Hydronic Cassette Fan Coil Units PRODUCT SELECTION DATA INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS EASY INSTALLATION PRODUCT SELECTION DATA EASY INSTALLATION INSTALLATION, OPERATION AND CENTRAL AIR DIFFUSION MAINTENANCE INSTRUCTIONS LOW ENERGY CONSUMPTION IMPROVED COMFORT ELEGANT AIR INLET GRILLE EXTREMELY QUIET OPERATION

More information

Ductless Split Systems

Ductless Split Systems Ductless Split s Right Product for the Right Application Ductless Split s Right Product for the Right Application 1:1 2:1 to 5:1 9-24K High Walls 18-24/6/42/60K High Walls, Cassette, Underceiling 2:1 to

More information

PRODUCT LINEUP VRF For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL

PRODUCT LINEUP VRF For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL IRSTGE Systems can be designed to create an air conditioning solution to suit most buildings requirements. IRSTGE Systems can be designed to effectively provide an air conditioning solution from a large

More information

CEILING CONCEALED SPLIT SYSTEM C SERIES

CEILING CONCEALED SPLIT SYSTEM C SERIES CEILING CONCEALED SPLIT SYSTEM C SERIES Microprocessor Controlled ith the microprocessor controlling the operation, the ACC model can offer comfortable room conditions according to the needs of the user.

More information

Ductless Split Systems

Ductless Split Systems Ductless Split s Right Product for the Right Application Ductless Split s Right Product for the Right Application 1:1 2:1 to 5:1 High Wall High Wall, Cassette, Underceiling 2:1 to 5:1 High Wall Up to 23.0

More information

Fan Coil Units. Technical Data

Fan Coil Units. Technical Data Fan Coil Units Technical Data F a n c o i l u n i t s E E D E N 1 1-4 0 0 Fan Coil Units Technical Data F a n c o i l u n i t s E E D E N 1 1-4 0 0 Table of Contents Table of Contents 3 Round Flow Cassette...

More information

Hi-Wall Inverter Split System. Efficient, effective and comfortable cooling and heating where you need it

Hi-Wall Inverter Split System. Efficient, effective and comfortable cooling and heating where you need it Hi-Wall Inverter Split System Efficient, effective and comfortable cooling and heating where you need it The Convenient Solution Feature Packed The Brivis Hi-Wall Inverter Split System has a pleasing,

More information

Product Data. Features/Benefits. 38HDL Cooling Only Condensing Unit. 1 1 / 2 to 5 Nominal Tons

Product Data. Features/Benefits. 38HDL Cooling Only Condensing Unit. 1 1 / 2 to 5 Nominal Tons Product Data 38HDL018-060 Cooling Only Condensing Unit 1 1 / 2 to 5 Nominal Tons The 38HDL energy-efficient condensing unit incorporates innovative technology to provide reliable cooling performance. Built

More information

VRF Indoor Unit 50Hz. Type: Wall Mounted M Series Wall Mounted S Series

VRF Indoor Unit 50Hz. Type: Wall Mounted M Series Wall Mounted S Series VRF Indoor Unit 50Hz Type: Wall Mounted M Series Wall Mounted S Series Contents 01 Wall Mounted M Series 20 Wall Mounted S Series MCAC-VTSM-2016-05 Wall Mounted M Series Wall Mounted M Series 1. Features...

More information

COMFORT FOR LIFE DUCTLESS WALL & FLOOR MOUNTED HIGH-EFFICIENCY HEAT PUMP 20 SEER UP TO 12.5 HSPF UP TO 13 EER INVERTER, VARIABLE-SPEED COMPRESSOR

COMFORT FOR LIFE DUCTLESS WALL & FLOOR MOUNTED HIGH-EFFICIENCY HEAT PUMP 20 SEER UP TO 12.5 HSPF UP TO 13 EER INVERTER, VARIABLE-SPEED COMPRESSOR 20 SERIES - ENHANCED CAPACITY DUCTLESS WALL & FLOOR MOUNTED HIGH-EFFICIENCY HEAT PUMP 20 SEER UP TO 12.5 HSPF UP TO 13 EER INVERTER, VARIABLE-SPEED COMPRESSOR COMFORT FOR LIFE www.daikincomfort.com "I'm

More information

technical data air conditioning systems Round Flow Cassette FXFQ-P9VEB

technical data air conditioning systems Round Flow Cassette FXFQ-P9VEB technical data Round Flow Cassette FXFQ-P9VEB air conditioning systems technical data Round Flow Cassette FXFQ-P9VEB air conditioning systems TABLE OF CONTENTS FXFQ-P9VEB 1 Specifications.......................................................

More information

Version Modification Date Remark

Version Modification Date Remark Version Modification Date Remark Products 1 Nomenclature... 2 Line-up... 3 Accessory... 1 Nomenclature 1-1. Nomenclature Model name AM RVX 45 1 HF TN T4 FD EE EH / EU 1 (Buyer) Classification AM DVM

More information

Space Saving. Comprehensive Product Range. Independent Circuit. Reliable & Efficient Rotary Compressor. Z - ODP (Zero Ozone Depletion Potential)

Space Saving. Comprehensive Product Range. Independent Circuit. Reliable & Efficient Rotary Compressor. Z - ODP (Zero Ozone Depletion Potential) MULTI SPLIT SYSTEMS Space Saving Only 1 outdoor is needed to couple with 2 or more indoors. Thus, this has effectively improved the floor space utilisation. The Multi-Split models are especially popular

More information

Multi-Room Ductless heat-pump systems Submittal Data: MULTI56HP230V1AO 56,000 BTUH Super +Multi-port Heat Pump System Job Name Location Date

Multi-Room Ductless heat-pump systems Submittal Data: MULTI56HP230V1AO 56,000 BTUH Super +Multi-port Heat Pump System Job Name Location Date Multi-Room Ductless heat-pump systems Submittal Data: 56,000 BTUH Super +Multi-port Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Reference Approval Construction Unit Designation

More information

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO technical sales guide - 60Hz Taurus R Ducted Split Units UPTO HIGH AMBIENT OPERATION 52 O C Page CONTENTS Nomenclature.. 2 Description. 3 Features.. 3 Product Data. 4 Condensing Unit Cooling Performance

More information

R22 TECHNICAL MANUAL. Split Unit Air Conditioner Ceiling Cassette C & E Series FF-C, FHC-E, FFY-C, FHYC-E. Cooling only & Heatpump [50Hz]

R22 TECHNICAL MANUAL. Split Unit Air Conditioner Ceiling Cassette C & E Series FF-C, FHC-E, FFY-C, FHYC-E. Cooling only & Heatpump [50Hz] R22 TECHNICAL MANUAL Split Unit Air Conditioner Ceiling Cassette C & E Series FF-C, FHC-E, FFY-C, FHYC-E Cooling only & Heatpump [50Hz] Table of Contents Table of Contents Nomenclature...1 Indoor...1

More information

Fan coil units. Why choose Daikin fan coil units? 540 Products overview 542. Options & accessories 560. Round flow cassette 544 FWC-BT/BF 544

Fan coil units. Why choose Daikin fan coil units? 540 Products overview 542. Options & accessories 560. Round flow cassette 544 FWC-BT/BF 544 Fan coil units Why choose Daikin fan coil units? 540 Products overview 542 Round flow cassette 544 FWC-BT/BF 544 4-way blow ceiling mounted cassettes 545 FWG-AT/AF 545 FWF-BT/BF 546 FWF-CT 547 Floor standing

More information

1. Features Specifications Dimensions Service Spaces Piping Diagrams Wiring Diagrams...

1. Features Specifications Dimensions Service Spaces Piping Diagrams Wiring Diagrams... MCAC-VTSM-2013-08 1. Features... 264 2. Specifications... 265 3. Dimensions... 268 4. Service Spaces... 272 5. Piping Diagrams... 273 6. Wiring Diagrams... 274 7. Capacity Tables... 276 8. Electrical Characteristics...

More information

Four steps static pressure set-up Easy to combine with different types of air diffusers R22 & R407c replacement technology

Four steps static pressure set-up Easy to combine with different types of air diffusers R22 & R407c replacement technology Slim Ducted Systems Two choices of selection for the air inlet flow Natural drain discharge port and drain pump (up to 850 mm) Cleanable pre-filter included Slim Ducted Systems Digital Inverter Four steps

More information

Cooling Compressor Type DC Inverter Driven Rotary Rated Capacity 48,000 BTU/H RLA 23.0 A

Cooling Compressor Type DC Inverter Driven Rotary Rated Capacity 48,000 BTU/H RLA 23.0 A Submittal Data: Multi-Room Ductless heat-pump systems 48,000 BTUH Super +Multi-port Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES

More information

Unique solutions FLEXY MATCH FLEXY MATCH FLEXY MATCH R410A FLUID AUTO AUTO CLEAN/DRY SLEEP MODE LOW BATTERY INDICATION WIRED CONTROL OPTION

Unique solutions FLEXY MATCH FLEXY MATCH FLEXY MATCH R410A FLUID AUTO AUTO CLEAN/DRY SLEEP MODE LOW BATTERY INDICATION WIRED CONTROL OPTION 2013 Catalogue Monosplit DCI HJD Unique solutions FLEXY MATCH ADVANCED CONTROL OPTIONS HIGH WALL MONO & PREMIUM MULTI FLEXY MATCH STERIONIZER q High wall line available in capacities 2.5 up to 7.5 kw.

More information

Technical Service Manual. TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph

Technical Service Manual. TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph Technical Service Manual TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor 220-240V/50-60Hz/1ph August 20 Medium Static Pressure Duct Unit With DC Fan Motor 1. Features...2 2. Specifications...4

More information

DOMESTIC // HEATING AND COOLING SYSTEMS EVERY ROOM MATTERS

DOMESTIC // HEATING AND COOLING SYSTEMS EVERY ROOM MATTERS 2010 DOMESTIC // HEATING AND COOLING SYSTEMS EVERY ROOM MATTERS WELCOME TO NEW DOMESTIC RANGE More than ever before, Panasonic has developed a range of products designed for you and your clients. The main

More information

V33B High Efficiency 360 Cassette Indoor Models - 60HZ

V33B High Efficiency 360 Cassette Indoor Models - 60HZ PRODUCT SPECIFICATIONS Low-sound, high efficiency cassette, encased in galvanized steel offers 360 airflow for immediate, equal distribution of wide-range cooling and heating. Cassette has motor-driven

More information

R410A DC Inverter Individual V4 Plus 50Hz 2012

R410A DC Inverter Individual V4 Plus 50Hz 2012 MCAC-2012-05 R410A DC Inverter Individual V4 Plus 50Hz 2012 Commercial Air Conditioner Business Units Midea Air Conditioning and Refrigeration Sector Add: West region of Midea commercial air conditioner

More information

SINGLE. Technical Data Book. 4Way Cassette S for Nordic (R410A, 50Hz) Model : AC***JN4CEH/EU (ODU: AC***JXSC*H/EU)

SINGLE. Technical Data Book. 4Way Cassette S for Nordic (R410A, 50Hz) Model : AC***JN4CEH/EU (ODU: AC***JXSC*H/EU) SINGLE Technical Data Book 4Way Cassette S for Nordic (R4A, 5Hz) Model : AC***JN4CEH/EU (ODU: AC***JXSC*H/EU) History Version Modification Date Remark Ver.1. Released SINGLE for Nordic TDB 15.3.. Ver.1.1

More information

2010 Duct-Free Splits Line Card

2010 Duct-Free Splits Line Card 2010 Duct-Free Splits Line Card Right Product for the Right Application 2010 Duct-Free Splits Right Product for the Right Application 1:1 2:1 to 4:1 9-24K High Walls 18-24/6/42/60K High Wall, Cassette,

More information

Cool with the sun and save 60% of your power

Cool with the sun and save 60% of your power Cool with the sun and save 60% of your power Saves up to 60% of your electrical power Same prices as non solar systems (incl. panel!) Top technology with attractive indoor units Heat pump for cooling and

More information

HEATING AND COOLING SOLUTIONS VRV-S RESIDENTIAL SYSTEMS PCVSAU1117

HEATING AND COOLING SOLUTIONS VRV-S RESIDENTIAL SYSTEMS PCVSAU1117 HEATING AND COOLING SOLUTIONS VRV-S RESIDENTIAL SYSTEMS PCVSAU1117 With the emerging trend towards double storey homes on smaller blocks, the compact size and horizontal discharge design of Daikin's VRV-S

More information

Braemar Air Conditioning Options. Get started

Braemar Air Conditioning Options. Get started Braemar Air Conditioning Options Get started Braemar airconditioning options Braemar by Seeley International offers a range of heating and cooling products for all types of applications, from single spaces

More information

PERFECTLY EVEN COOLING CIRCULAR DESIGN 360 CASSETTE. The World s First Circular Cassette. Circular LED Display Window. 360 Air Flow Blade-less

PERFECTLY EVEN COOLING CIRCULAR DESIGN 360 CASSETTE. The World s First Circular Cassette. Circular LED Display Window. 360 Air Flow Blade-less Air Conditioning Solutions 2016 360 CASSETTE CIRCULAR DESIGN Its full-circle design allows it to be placed beautifully in any setting. PERFECTLY EVEN COOLING Innovative 360 degree airflow ensures optimal

More information

Product Data. Features/Benefits 50JS SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS)

Product Data. Features/Benefits 50JS SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS) SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS) Product Data UNIT (50 Hz) Single-packaged Heat Pump for Residential and Light Commercial applications. Features/Benefits One-piece

More information

SUBMITTAL DATA: MXZ-5C42NAHZ MULTI-INDOOR INVERTER HEAT PUMP SYSTEM. Power Supply Voltage, Phase, Hertz 208 / 230V, 1-Phase, 60 Hz

SUBMITTAL DATA: MXZ-5C42NAHZ MULTI-INDOOR INVERTER HEAT PUMP SYSTEM. Power Supply Voltage, Phase, Hertz 208 / 230V, 1-Phase, 60 Hz M-SERIES SUBMITTAL DATA: MXZ-5C42NAHZ MULTI-INDOOR INVERTER HEAT PUMP SYSTEM Job Name: System Reference: Date: Outdoor Unit: MXZ-5C42NAHZ ACCESSORIES Three-port Branch Box (PAC-MKA30BC) Five-port Branch

More information

PRODUCT LINEUP MULTI SPLIT

PRODUCT LINEUP MULTI SPLIT 068 PRODUCT LINEUP Energy saving design to provide a comfortable indoor environment while being environment-friendly. An air conditioner that is people-friendly is also environment friendly. Fujitsu General

More information

Ductless Split Systems

Ductless Split Systems Ductless Split s Right Product for the Right Application Ductless Split s Right Product for the Right Application 1:1 2:1 to 4:1 9-24K High Walls 18-24/6/42/60K High Wall, Cassette, Underceiling 2:1 to

More information

VMDA Concealed Medium Static Ducted Indoor Models - 60HZ

VMDA Concealed Medium Static Ducted Indoor Models - 60HZ VARIABLE REFRIGERANT FLOW SYSTEMS VRF VMDA Concealed Medium Static Ducted Indoor Models - 60HZ PRODUCT ECIFICATIONS Slim, compact design for limited space requirements. Installs out of sight between the

More information

VRF Mini Series 50Hz. Commercial Air Conditioners Commercial Air Conditioner Division Midea Group

VRF Mini Series 50Hz. Commercial Air Conditioners Commercial Air Conditioner Division Midea Group Coercial Air Conditioners 16 VRF Mini Series 50Hz Midea CAC After-service Application Midea CAC News Application Coercial Air Conditioner Division Midea Group Add.: West Region of Midea Coercial Air Conditioner

More information

EFFICIENT SOLUTIONS PRICE LIST 2017 / 2018

EFFICIENT SOLUTIONS PRICE LIST 2017 / 2018 PRODUCTS 2017 2018 EFFICIENT SOLUTIONS PRICE LIST 2017 / 2018 PANASONIC PANASONIC: ECO & SMART IDEAS FOR A SUSTAINABLE LIFESTYLE Panasonic Green Innovation Company. We will make the environment central

More information

FFQN-C, FCRN-E, FFRN-C

FFQN-C, FCRN-E, FFRN-C R410A TECHNICAL MANUAL Split Unit Air Conditioner Ceiling Cassette C & E Series FCQN-E, FFQN-C, FCRN-E, FFRN-C Cooling only & Heatpump [50Hz] DAIKIN_FFRN.indb i 12/27/2012 9:28:06 AM DAIKIN_FFRN.indb ii

More information

Chiller, Close control and Water terminals. Air Conditioning. Light Commercial, Commercial and Industrial

Chiller, Close control and Water terminals. Air Conditioning. Light Commercial, Commercial and Industrial Chiller, Close control and Water terminals Air Conditioning Light Commercial, Commercial and Industrial Water Terminals 133 Water Terminals Fan coils & Cassette Centrifugal fan-coil SYSCOIL Ductable fan-coil

More information

VRV-S RESIDENTIAL SYSTEMS PCVSAU0616 HEATING & COOLING SOLUTIONS

VRV-S RESIDENTIAL SYSTEMS PCVSAU0616 HEATING & COOLING SOLUTIONS VRV-S RESIDENTIAL SYSTEMS PCVSAU0616 HEATING & COOLING SOLUTIONS BRINGING INNOVATION TO YOUR HOME With the emerging trend towards double storey homes on smaller blocks, the compact size and horizontal

More information

BAC / BHC Product Specifications

BAC / BHC Product Specifications COMMERCIAL AIR HANDLERS (3 PHASE) 6 to 20 TON / Product Specifications REFRIGERATION CIRCUIT Standard factory-installed thermostatic expansion valves (TXVs) on units; units include TXVs and check valves

More information

HIGH-EFFICIENCY MINI-SPLIT AIR CONDITIONERS AND HEAT PUMPS

HIGH-EFFICIENCY MINI-SPLIT AIR CONDITIONERS AND HEAT PUMPS UP TO 20 SEER PERFORMANCE HIGH-EFFICIENCY MINI-SPLIT AIR CONDITIONERS AND HEAT PUMPS Energy Star ratings are dependent upon conditions beyond equipment installation. To make certain your HVAC equipment

More information

Engineering Data Book. High Static Duct 8, 10HP Digital Inverter. Indoor Unit. Outdoor Unit

Engineering Data Book. High Static Duct 8, 10HP Digital Inverter. Indoor Unit. Outdoor Unit E10-1 High Static Duct 8, 10HP Digital Inverter Engineering Data Book Indoor Unit RAV-SM2242DT-E RAV-SM2802DT-E RAV-SM2242DT-TR RAV-SM2802DT-TR Outdoor Unit RAV-SM2244AT8-E RAV-SM2804AT8-E Contents 1 Specifications..............................................................

More information

Landmark Rooftop Packaged Units

Landmark Rooftop Packaged Units Landmark Rooftop Packaged Units Engineered for superior performance and reliability Exclusively distributed by AUS - 13 23 50 www.lennoxaus.com.au NZ - 0800 653 330 www.lennoxnz.co.nz 1 Landmark Rooftop

More information

Ductless Systems. Right product for the right application. Fall 2015 Edition

Ductless Systems. Right product for the right application. Fall 2015 Edition Ductless Systems Right product for the right application Fall 2015 Edition Right Product for the Right Application Single Zone - Residential Single Zone - Light Commercial Multi-Zone RAV-**KRT System High

More information

Multizone Multi Split systems

Multizone Multi Split systems 19 Multizone Multi Split systems Features and Benefits 2 Room 3 Room 4 Room 5 Room 6 Room RAM-36NP2A RAM-53NP2A RAM-53NP3A RAM-68NP3A RAM-70NP4A RAM-90NP5A RAM-130NP6A Nominal Cooling Capacity (kw) 3.6

More information

M-SERIES MHP4 MODEL NUMBER GUIDE 3 M HP F P 1 ELECTRIC HEAT PUMP PACKAGED UNITS REVISION CODE

M-SERIES MHP4 MODEL NUMBER GUIDE 3 M HP F P 1 ELECTRIC HEAT PUMP PACKAGED UNITS REVISION CODE ELECTRIC HEAT PUMP PACKAGED UNITS MHP4 FORM NO. MHP4-100 (10/2018) MODEL NUMBER GUIDE 3 M HP 4 11 18 1 F P 1 FACTORY INSTALLED ELECTRIC HEAT 3= 3 KW 5 = 5 KW 7 = 7 KW 10 = 10 KW M = MAGIC-PAK HP = HEAT

More information

Cooling Compressor Type DC Inverter Driven Rotary Rated Capacity 53,000 BTU/H RLA 23.0 A

Cooling Compressor Type DC Inverter Driven Rotary Rated Capacity 53,000 BTU/H RLA 23.0 A Submittal Data: Multi-Room Ductless heat-pump systems 56,000 BTUH Super +Multi-port Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES

More information

Digital Inverter 4 series

Digital Inverter 4 series TCTC-E14-LC005-2 Digital Inverter 4 series Outdoor Unit RAV-SM304ATP-E RAV-SM304ATJP-E RAV-SM4ATP-E RAV-SM4ATJP-E I ndoor Unit RAV-SM307KRTP-E RAV-SM7KRTP-E RAV-SM7CTP-E RAV-SM304MUT-E RAV-SM4MUT-E RAV-SM304SDT-E

More information

AIR HANDLING UNITS YSE

AIR HANDLING UNITS YSE IR DIG UITS YSE YSE Series ir andling Units YORK YSE Series ir andling Units are designed to provide a comfortable environment for factories, warehouses, office and stores etc. The coils can be used to

More information

Models: 12 and 18. Models: 24 to 60

Models: 12 and 18. Models: 24 to 60 SPLIT CASSETTE TYPE MUCSR-H8 Series SCOP 4.0 Models: 12 and 18 RG57B2/BGE Included (CL 94 982) Models: 24 to 60 Design 360 Thanks to the 360 panel design, the air is more evenly distributed. Drainage pump

More information

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE. TECHNICAL SELECTION DATA PACKAGE UNIT + o C -10 o C 3 THREE PHASE SCROLL TWO STAGE CENTRIFUGAL LOUVRE LIANT SCROLL RESSOR AXIAL UNIT FEATURES SPECIFICATION SUMMARY Scroll Compressor Multiple Speed Outdoor

More information

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS R FORM NO: MS0305F Products That Perform...By People Who Care AIR - COOLED SPLIT SYSTEM AIR CONDITIONERS WITH SCROLL COMPRESSORS 50 Hz COOLING CAPACITY- 60 MBH TO 1360 MBH ACCS SERIES HEB-D, EB-D SERIES

More information

Low Static Pressure Duct(V shape evaporator)

Low Static Pressure Duct(V shape evaporator) Low Static Pressure Duct (V shape evaporator) 1. Features... 116 2. Specifications... 118 3. Dimensions... 121 4. Service Spaces... 123 5. Piping Diagrams... 124 7.Fan Performance... 126 8.Capacity Tables...

More information

VRF. Technical Data Book. Ceiling for America (R410A, 60Hz, HP) Model : AM***FNCDCH***

VRF. Technical Data Book. Ceiling for America (R410A, 60Hz, HP) Model : AM***FNCDCH*** VRF Technical Data Book Ceiling for America (R410A, 60Hz, HP) Model : AM***FNCDCH*** History Version Modification Date Remark Ver.1.0 Release Ceiling for America (R410A, 60Hz, HP) 15.11.04 - 1 Nomenclature

More information

TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS

TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS Version.MDT-2016.T3.103 TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS FEATURES AND BENEFITS COMPRESSOR: Compressors are protected with internal temperature and current overloads. An internal

More information