1 Snow Melting Mats Price Sheet EFFECTIVE : 201 WarmlyYours Snow Melting Mats are available in a variety of sizes and voltages to meet your requirements. The following pricing guide has been designed to help you estimate the system expense portion of your snow melting project. Don t forget to add the cost of system installation, electrical hook-up and your choice of controls (see companion price sheet) to finalize your project pricing. 120 VOLT SNOW MELTING MATS FOR INSTALLATI IN ASPHALT, CCRETE, AND IN MORTAR UNDER PAVERS. Part #: Size (ft/cm) Voltage Area (ft 2 /m 2 ) Total Watts Amps Heated Cable Length (ft/m) WHMA ' x ' (1 x 12cm) (.9m 2 ) (1.0m) 2.9 (1. kg) $20.00 WHMA x (91 x 12cm) (1.9m 2 ) (19.1m). (2.0 kg) $2.00 WHMA x 10 (1 x 0cm) (1.m 2 ) 1,000.. (2.0m).0 (2. kg) $12.00 WHMA x 10 (91 x 0cm) (2.9m 2 ) 1, (.2m). (.0 kg) $2.00 WHMA x 1 (1 x cm) (2.9m 2 ) 1, (9.11m). (.0 kg) $2.00 WHMA x 1 (91 x cm) 120 (.1m 2 ) 2, (.1m) 9.0 (.1 kg) $ VOLT SNOW MELTING MATS FOR INSTALLATI IN ASPHALT, CCRETE, AND IN MORTAR UNDER PAVERS. Part #: Size (ft/cm) Voltage Area (ft 2 /m 2 ) Total Watts Amps Heated Cable Length (ft/m) WHMA x 10 (1 x 12cm) (1.m 2 ) 1, (2.0m). (2.0 kg) $12.00 WHMA x 1 (1 x cm) 20 0 (2.9m 2 ) 1, (9.11m). (.0 kg) $2.00 WHMA x 20 (1 x 10 cm) 20 0 (.2m 2 ) 2, (2.1m). (. kg) $1.00 WHMA x 0 (1 x 91cm) 20 0 (.m 2 ), (.22m) 11. (.2 kg) $20.00 WHMA x 0 (1 x 1219cm) 20 0 (.m 2 ), (10.29m) 1.2 (.9 kg) $.00 WHMA x 0 (1 x 12cm) (9.29m 2 ), (10.m) 19.0 (. kg) $1,0.00 WHMA x 10 (91 x 12cm) 20 0 (2.9m 2 ) 1, (.2m). (.0 kg) $2.00 WHMA x 1 (91 x cm) 20 (.1m 2 ) 2, (.1m) 9.0 (.1 kg) $0.00 WHMA x 20 (91 x 10cm) 20 0 (.m 2 ), (.m) 11. (.2 kg) $20.00 WHMA x 0 (91 x 91cm) (.m 2 ), (11.1m) 1.2 (. kg) $9.00 * Shipping weights may vary. Installation Support (00) -2
2 Snow Melting Cables Price Sheet EFFECTIVE : 201 WarmlyYours Snow and Slabheating Cables are available in a variety of sizes and voltages to meet your requirements. The following pricing guide has been designed to help you estimate the system expense portion of your project. Don t forget to add the cost of system installation, electrical hook-up and your choice of controls (see companion price sheet) to finalize your project pricing. 120 VOLT SNOW MELTING CABLES FOR INSTALLATI IN ASPHALT, CCRETE, AND IN MORTAR UNDER PAVERS. WHCA (1.0m) (1.1 kg) $21.00 WHCA (19.1m) (1. kg) $2.00 WHCA (2.0m) 120 1,000.. (1.9 kg) $22.00 WHCA (.2m) 120 1, (2. kg) $90.00 WHCA (.1m) 120 2, (.0 kg) $ VOLT SNOW MELTING CABLES FOR INSTALLATI IN ASPHALT, CCRETE, AND IN MORTAR UNDER PAVERS. WHCA (2.0m) 20 1, (1.9 kg) $22.00 WHCA (9.11m) 20 1, (2. kg) $90.00 WHCA (2.1m) 20 2, (. kg) $2.00 WHCA (.1m) 20 2, (.0 kg) $.00 WHCA (.m) 20, (.2 kg) $2.00 WHCA (10.29m) 20, (.2 kg) $.00 WHCA (11.1m) 20, (. kg) $.00 WHCA (10.m) 20, (. kg) $90.00 * Shipping weights may vary. Installation Support (00) -2
3 WarmlyYours Snow Melting Cables are available in a variety of sizes and voltages to meet your requirements. The following pricing guide has been designed to help you estimate the system expense portion of your project. Don t forget to add the cost of system installation, electrical hook-up and your choice of controls (see companion price sheet) to finalize your project pricing. 20 VOLT SNOW MELTING CABLES FOR INSTALLATI IN ASPHALT, CCRETE, AND IN MORTAR UNDER PAVERS. Coverage (Sq. Ft.) WHCA ' 20 1, $9.00 WHCA ' 20 1, $.00 WHCA ' 20 2, $1.00 WHCA ' 20 2, $.00 WHCA ' 20, $0.00 WHCA ' 20, $0.00 WHCA-20-0 ' 20, $ VOLT SNOW MELTING CABLES FOR INSTALLATI IN ASPHALT, CCRETE, AND IN MORTAR UNDER PAVERS. Coverage (Sq. Ft.) WHCA ' 2 1, $9.00 WHCA ' 2 1, $.00 WHCA ' 2 2, $1.00 WHCA ' 2 2, $.00 WHCA ' 2, $0.00 WHCA ' 2, $0.00 WHCA-2-0 ' 2, $ WHCA ' 2, $1, WHCA ' 2, $1,1.00 * Shipping weights may vary. Installation Support (00) -2
4 Ice Shield Self-Regulating Roof & Gutter Deicing Cables Price Sheet EFFECTIVE : 201 ICE SHIELD SELF-REGULATING ROOF & GUTTER DEICING CABLES PART # Voltage Watts per Foot MRSP ET-SR VAC Watts per ft dry / 9.2 Watts per ft in Ice (Dry vs. in Ice) $.00 ET-SR VAC 1-phase Watts per ft dry /.1 Watts per ft in Ice (Dry vs. in Ice) $.00 ET-SR VAC Watts per ft dry / 9.2 Watts per ft in Ice (Dry vs. in Ice) $.00 ET-SR-20 2 VAC Watts per ft dry / 10.2 Watts per ft in Ice (Dry vs. in Ice) $.00 ICE SHIELD CSTANT WATTAGE ROOF & GUTTER DEICING KITS ETC120-W-00-WY 120 VAC 0-ft. Cable Kit (-W per ft.) $.00 ETC120-W-00-WY 120 VAC 0-ft. Cable Kit (-W per ft.) $9.00 ETC120-W-00-WY 120 VAC 0-ft. Cable Kit (-W per ft.) $99.00 ETC120-W-100-WY 120 VAC 100-ft. Cable Kit (-W per ft.) $ CTROLS, SENSORS, THERMOSTATS, RELAY PANELS Premium and Advanced Control SCP-120 SCA-DUAL Snow and Ice Melting Control Premium Automatic, 120 V, adjustable timer, heater cycle switch, high temperature cut-off sensor, C-UL-US Snow and Ice Melting Automatic Control can operate at 120V, 20V, 20V, and 2V, adjustable timer, heater cycle switch, 0 amps maximum resistive load, C-UL-US $2, $00.00 AIR-SS Aerial mounted snow sensor, low voltage, detects moisture & ambient air temperature $00.00 GTR-SS Gutter mounted ice sensor, low voltage, detects moisture & ambient air temperature $90.00 RCO Remote manual override control, low voltage, single gang device $ ECOMY CTROL SCE-120 Snow and Ice Melting Control Economy, digital interface, ambient temperature and gutter sensors, CSA Certified $0.00 SCE-AMB-SS Ambient Temperature Sensor, wall mounted $0.00 SCE-GTM-SS Gutter moisture sensor, gutter or downpipe mounted $00.00 MANUAL CTROL SCM-120 Snow Melt Timer Control, 120 V, front cover timer adjustable up to 12 hours, UL Listed $0.00 THERMOSTAT AIR-STAT RELAYS Roof and Gutter Deicing Thermostat, outdoor rated, detects ambient air temperature, activates system at 0F or below, capillary style sensor, 120 V, 20 V, or 20 V, 22 amps maximum resistive load, UL/CSA $0.00 RLY-PL Indoor rated relay panel - two 2-pole 2 amp rated relays, with terminals $0.00 RLY-PL Indoor rated relay panel - four 2-pole 2 amp rated relays, with terminals $90.00 RLY-12PL Indoor rated relay panel - six 2-pole 2 amp rated relays, with terminals $0.00 ACCESSORIES SR-PWR-KIT Power Connection Kit (with End Seal Kit JSR12) $0.00 SR-PLUG-KIT Plug-in Conversion Kit with GFEP for Self-Regulating Heating Cable (Includes End-Seal Kit) $.00 ET-CL-AL-P2 Aluminum -prong clips attach to asphalt shingles and metal gutters and roofs (2) $.00 ET-VHB-PAD-P2 Double sided tape pads for CL-AL clips ( sold in pkgs of 2 ) $0.00 ET-9-PRIMER 1 Quart Primer - Adheres clips to EPDM or Rubber $90.00 Installation Support (00) -2
5 Pipe Tracing Cables Price Sheet EFFECTIVE : 201 PRO-Tect: Pipe Freeze Protection Self-Regulating Heating Cable PART # Voltage Watts per Foot MRSP (per foot) PT-SR Pipe Freeze Protection Cable (1 ft), -Watts / ft. $.00 PT-SR Pipe Freeze Protection Cable (1 ft), -Watts / ft. $.20 PT-SR Pipe Freeze Protection Cable (1 ft), 10-Watts / ft. $.0 PT-SR /20/2 Pipe Freeze Protection Cable (1 ft), -Watts / ft. $.00 PT-SR /20/2 Pipe Freeze Protection Cable (1 ft), -Watts / ft. $.20 PT-SR /20/2 Pipe Freeze Protection Cable (1 ft), 10-Watts / ft. $.0 PRO-Tect: Pipe Freeze Protection Controls SR-PLUG-KIT Plug-in Conversion Kit with GFEP for Self-Regulating Heating Cable (Includes End-Seal Kit) $.00 AIR-STAT Waterproof Outdoor Thermostat for Pipe Freeze Protection or Roof and Gutter Deicing Systems $0.00 PT-DUAL PRO-Tect: Pipe Freeze Protection Dual-Zone Control with GFEP $1,99.00 PT-SINGLE PRO-Tect: Pipe Freeze Protection Single-Zone Control with GFEP $1,19.00 PT-ECOMY PRO-Tect: Pipe Freeze Protection Economy Control with GFEP $99.00 PRO-Tect: Pipe Freeze Protection Accessories PT-END-KIT-H Pipe Freeze Protection End Seal Termination Kit (Hazardous Location Rated) $0.00 PT-LABEL-RED Pipe Freeze Protection Warning Labels - Red $1.00 PT-PWR-KIT-H Pipe Freeze Protection Power Connection Box with Heat Shrinks (Hazardous Location Rated) $20.00 PT-SPLICE-L-H Pipe Freeze Protection In-Line Splice Kit (Hazardous Location Rated) $10.00 PT-SPLICE-T-H Pipe Freeze Protection T-Splice Kit (Hazardous Location Rated) $ PT-SPLICE Pipe Freeze Protection Splice Kit (for In-Line and T-Splice) $.00 PT-TAPE-AL Pipe Freeze Protection Aluminum Tape 2 in. x 9 ft. $1.00 PT-TAPE-FG Pipe Freeze Protection Fiberglass Tape 1/2 in. x ft $.00 SR-PWR-KIT Power Connection Kit (with End Seal Kit JSR12) $0.00 Installation Support (00) -2
6 Snow Melting Controls Price Sheet EFFECTIVE : 201 WarmlyYours Snow Melting Systems are offered with a variety of Control Options to meet your needs and requirements. All controls come with easy-to-follow installation instructions. For more detailed information, contact your Account Manager at (00) -2. Illustration Description For Use With SCP-120 Premium Snow Melt Control, 120 Volt Use with AIR-SS $2, SCA-DUAL Advanced Snow Melt Control 100-2VAC Use with AIR-SS $00.00 AIR-SS Aerial-Mounted Snow Sensor, 2 Volt Use with SCP-120 and/or the SCA-DUAL $00.00 RCO Remote Manual Override 2 Volt Use with SCP-120 and/or the SCA-DUAL $ SCE-120 Economy Snow Melt Control, 120 Volt Use with SLAB-SS $0.00 SCE-SLAB-SS-KIT Snow Melting Slab Sensor Kit (ETOG- Sensor + Housing) Use with SCE-120 $19.00 SCM-120 Snow Melt Timer Control, 120 Volt Stand Alone $0.00 SCV-DUAL Value Snow Melt Control Dual Voltage, (120V / 20V) Stand Alone $0.00 RLY-PL Small Relay Panel, 120 Coil Voltage, (2) 2-Pole RLY-PL Medium Relay Panel, 120 Coil Voltage, () 2-Pole RLY-12PL Large Relay Panel, 120 Coil Voltage, () 2-Pole SMP Snow Melt Plaque Use with all Snow Melting Installations $.00 SCPM-CO-120- Power Modulator Electrical Box Operates up to zones $,00.00 SCPM-SS-120 Power Modulator Snow/Ice Aerial Sensor Power Modulator Electrical Box & $90.00 SCPM-WM-120 Power Modulator Wall-Mounting Bracket for Aerial Sensor Use with SCPM-SS-120 $ Item Number $0.00 A minimum of 1 Relay Panel is required per Snow Melting System $90.00 $0.00 Installation Support (00) -2
WarmlyYours ET-SR Series Heating Cable Installation Manual for Roof & Gutter Deicing
WarmlyYours ET-SR Series Heating Cable Installation Manual for Roof & Gutter Deicing Free Design Service 24/7 Installation Support (800) 875-5285 www.warmlyyours.com Assembly Tools Needed Utility knife
More informationPRO-Tect Pipe Freeze Protection Self-Regulating Heating Cable Install Manual (PT-Series)
PRO-Tect Pipe Freeze Protection Self-Regulating Heating Cable Install Manual () Free Design Service 24/7 Installation Support (800) 875-5285 www.warmlyyours.com Assembly Tools Needed Utility knife Wire
More information3M Self Regulating Heating Cables
2 Construction & Function 3M Self Regulating Heating Cables Introduction: 3M Canada and Thermon Manufacturing Company have entered into a strategic alliance to market the commercial line of heat tracing
More informationSelection Guide. Freeze Protection Heating Cable. Thermwire - Wrap. Thermwire - Wrap Pre-Assembled. Thermwire - Comp. Thermwire - Melt.
Thermwire Freeze Protection Heating Cable Selection Guide Thermwire - Wrap Pipe Freeze Protection Heating Cable Thermwire - Wrap Pre-Assembled Pipe Freeze Protection Heating Cable with Attached Cord &
More informationElectric Heating Product Catalog
Version #: VKAPA922 Electric Heating Product Catalog LX Electric Floor Heating, GX Snow Melting, RX Roof & Gutter De-Icing, PX Pipe Freeze Protection, TX Thermal Storage COMFORT and safety solutions for
More informationElectric Heating Product Catalog
Version #: VKAPA522 Electric Heating Product Catalog LX Electric Floor Heating, GX Snow Melting, RX Roof & Gutter De-Icing, PX Pipe Freeze Protection, TX Thermal Storage www.heating.danfoss.us Danfoss
More informationDanfoss Electric Heating Products 2012 CATALOG BRINGING WARMTH TO LIFE. Electric Floor Heating
BRINGING WARMTH TO LIFE Electric Floor Heating Electric Snow Melting Roof & Gutter De-Icing Pipe Freeze Protection Thermal Storage PG. 1 PG. 9 PG. 21 PG. 25 PG. 31 Danfoss Electric Heating Products 2012
More informationET-PWR-END-KIT Installation Instructions (part #JSR00)
(part #JSR00) Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety
More information120/240 Volts 3 Watt Floor Heating Cable System
WA-3CWC 120/240 Volts 3 Watt Floor Heating Cable System Warm Cable floor heating system combines the highest comfort levels with maximum energy efficiency. It is a proven technology that is safe, reliable
More informationDOMESTIC USE. Anti-freeze for Piping CONSTANT POWER. Anti-freeze for Ramps. Stop Ice Constant power anti-freeze kit complete with thermostat and plug
DOMESTIC USE Anti-freeze for Piping CONSTANT POWER page 190 Stop Ice Constant power anti-freeze kit complete with thermostat and plug Linus Self-adhesive thermal insulating tape Stop Ice Plus Constant
More informationCommercial Radiant HeaterRH Series
RH A 33 C 1 D E 25W F A: Series : Length C: Housing Color -lack, S-Stainless D: Lamp Quantity E: Volts A=120, =208 C=240, D=480, E=575 F: Wattage lack powder-coat aluminized steel housing Optional stainless
More informationNAMSR SELF-REGULATING CABLE FOR PIPE FREEZE PROTECTION / SPECIFICATION SHEET WSC-0930
PRODUCT CODES NAMSR-Wattage-Voltage-Length. Ex: NAMSR-8W-120-250 PRODUCT DESCRIPTION Warmup NAMSR cable is suited to prevent liquids in metal and plastic s and ducts to freeze and clog up. It is regularly
More informationNAMSR SELF-REGULATING CABLE FOR PIPE FREEZE PROTECTION / SPECIFICATION SHEET WSC-0930
PRODUCT CODES NAMSR-Wattage-Voltage-Length // eg: NAMSR-8W-120-250 PRODUCT DESCRIPTION Warmup NAMSR cable is suited to prevent liquids in metal and plastic s and ducts to freeze and clog up. It is regularly
More informationNAMSR SELF-REGULATING FREEZE PROTECTION HEATING CABLE SELECTION
Self-Regulating, Energy Efficient Cost Effective for Contractor/Construction Freeze Protection Application Industrial Grade, 16 AWG Buss Wire Standard Braid with Overjacket Circuit Lengths to 460 Feet
More informationV (For 120, 208, 277, 600 V, please call.) Output: 37 W/ft 2 and 50W/ft 2 Cold lead:
Snow Melting Mats Data Sheet GENERAL PRODUCT INFORMATION ProLine snow melting mats feature pre-spaced heat cable (3 and 4-inch spacing) in mats that can be rolled out for quick, easy installation. To make
More informationElectric Heating Product Catalog
Version #: VKAPA422 Electric Heating Product Catalog LX Electric Floor Heating, GX Snow Melting, RX Roof & Gutter De-Icing, PX Pipe Freeze Protection, TX Thermal Storage www.lx.danfoss.com Danfoss offers
More informationInstallation Instructions CONSTANT WATT (CW) AND SELF-REGULATING (SR) PIPE TRACING CABLES
Installation Instructions CONSTANT WATT (CW) AND SELF-REGULATING (SR) TRACING S CONTENTS page Constant Watt Cable Self-Regulating Cable SECTION 1. OVERVIEW 1.1 Precautions... 2 1.2 Cable and components...
More informationMODEL HSC-24 AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL
MODEL HSC-24 AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL DESCRIPTION The Snow Switch Model HSC-24, 24-volt Pavement-Mounted Snow and Ice Sensor reliably detects snow and ice conditions on pavement
More informationPower Connection Kit installation instructions
Operating instructions & Parts Manual ET00 Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and
More informationHeating Cable. Description
203312 Single Entry Connection Box NEMA 4X Entry for 1 Cable 3/4 Conduit Hub Opening Multiple Entry Connection Box NEMA 4X Entry for up to 3 Cables Power or Tee Connection 3/4 Conduit Hub Opening End Seal
More informationSnow Switch Models HSC 4 (P/N 24220) & HSC 5 (P/N 24221)
Description The Snow Switch Model HSC 4 and HSC 5 Pavement-Mounted Deicing Controllers reliably operate snow and ice melting heaters based upon pavement conditions. This ensures that deicing heaters operate
More informationType LT Self-Regulating Heater Cable For use in Ordinary (Unclassified) and Hazardous (Classified) Locations
F, G ;, Class I, Class Groups F, G; Operating Principle The parallel bus wires apply voltage along the entire length of the heater cable. The conductive core provides an infinite number of parallel conductive
More informationMODEL SIT -6E PAVEMENT-MOUNTED SNOW AND ICE SENSOR
MODEL SIT -6E PAVEMENT-MOUNTED SNOW AND ICE SENSOR DESCRIPTION The Snow Switch Model SIT 6E Pavement-Mounted Snow and Ice Sensor reliably detects snow and ice conditions on pavement surfaces when used
More informationSelf-Regulating Freeze Protection Heating Cable
D PDS SRF Self-Regulating Freeze Protection Heating Cable E C B A Output Self-Regulating, Energy Efficient Cost Effective for Contractor/Construction Freeze Protection Application Freeze Protection of
More informationInstallation Instructions Mineral Insulated (M.I.)
Installation Instructions Mineral Insulated (M.I.) trace ASSEMBLY Contents page Section 1. Overview 1.1 Precautions... 2 1.2 M.I. cable and components... 2 1.3 General accessories... 3 1.4 Tools required...
More informationSRK02 Hard Wire Power Connection Kit. Installation, Operation and Maintenance Instructions
SRK02 Hard Wire Power Connection Kit Installation, Operation and Maintenance Instructions IMPORTANT: Save These Instructions! Item Qty Description A 1 Black heat shrink tube (1/2 dia. x 1 length) B 2 Black
More informationHeating Cable. Description
203312 Single Entry Connection Box NEMA 4X Entry for 1 Cable 3/4 Conduit Hub Opening Multiple Entry Connection Box NEMA 4X Entry for up to 3 Cables Power or Tee Connection 3/4 Conduit Hub Opening End Seal
More informationSAFETY INFORMATION AND WARNINGS
SAFETY INFORMATION AND WARNINGS Abnormal Odor or Smoke In the event of smoke or a burning or abnormal odor, immediately interrupt power to the unit by unplugging the unit or by turning off the circuit
More informationElectroMelt System INSTALLATION AND OPERATION MANUAL FOR SURFACE SNOW MELTING AND ANTI-ICING SYSTEMS
ElectroMelt System INSTALLATION AND OPERATION MANUAL FOR SURFACE SNOW MELTING AND ANTI-ICING SYSTEMS THERMAl MANAGEMENT WWW.PENTAIRTHERMAl.COM Important Safeguards and Warnings WARNING: FIRE AND SHOCK
More informationNuheat WEATHER-READY HEAT TRACE PIPE FREEZE PROTECTION SYSTEM. Self-Regulating Heating Cable Installation Guide. UV Resistant Polyolefin Outer Jacket
Nuheat WEATHER-READY HEAT TRACE PIPE FREEZE PROTECTION SYSTEM Self-Regulating Heating Cable Installation Guide Tinned Copper Braid UV Resistant Polyolefin Outer Jacket 16 AWG Bus Wire Polyolefin Inner
More informationUPS packages are charged dimensional, not physical weight.
Electric Heater Packing List NOTE: All items shown in this booklet are part of our EL and TBAC price code categories. Heaters & Accessories Effective 7-1-13 All orders are subject to acceptance by Detroit
More informationSAFETY INFORMATION AND WARNINGS
This manual refers to the control panel manufactured since October 31, 2013, which uses a universal (100 277 VAC; 50/60 Hz) power supply. Older units use a voltage-specific power supply and have different
More informationFLX TM Self-Regulating Winterization/Freeze Protection INSTALLATION PROCEDURES
FLX TM Self-Regulating Winterization/Freeze Protection INSTALLATION PROCEDURES FLX TM Self-Regulating Refer to the FLX Cable Testing Report for required recording of test data and circuit information.
More informationHeating Cable. Cut to Length in Field. Description
Self-Regulating Freeze Protection D E C B A Self-Regulating, Energy Efficient Designed for Freeze Protection Max. Exposure Temp. 185 F Temperature Cost Effective for Commercial Construction Freeze Protection
More informationDanfoss LX Electric Floor Heating
Danfoss LX Electric Floor Heating Electric Floor Heating Thermostats The Danfoss LX Thermostat raises the bar for aesthetic appeal while offering industry-leading functionality. The LX electronic thermostat
More informationPictorial Index... A-14 Introduction to Heat Trace Cable Systems Installation Examples Engineering Guide Heat Loss Tables...
Pictorial Index....................... A-14 Introduction to Heat Trace Cable Systems............... 6-2 Installation Examples................... 6-3 Engineering Guide..................... 6-4 Heat Loss
More informationKompensator External Low Voltage Heating Cable System
External Low Voltage Heating Cable System LOW VOLTAGE Installation Instructions General Information Kit Contents Qty Description 1 heating cable at pre-determined length Table of Contents General Information........................
More informationType LT Self-Regulating Heater Cable For use in Ordinary and Hazardous (Classified) Locations
A, I, A, Operating Principle The parallel bus wires apply voltage along the entire length of the heater cable. The conductive core provides an infinite number of parallel conductive paths permitting the
More informationINDUSTRIAL HEAT TRACE
INDUSTRIAL HEAT TRACE INDUSTRIAL HEAT TRACE www.valin.com 800-774-5630 www.valin.com HTS-6 SERIES The HTS-6 commercial grade heater cable is designed for use in both indoor and outdoor locations as well
More informationThe advantages of the pipe tracing systems are: Sensor. Insulation Heating cable Aluminium tape. Fig. 1 Fig. 2
28 3 Pipe tracing 3.1 General information DEVI s pipe tracing systems consist of deviflex heating cables, devireg thermostats and installation accessories. The devireg thermostats with sensors ensure that
More informationMI HEATING CABLE COPPER AND HDPE JACKETED COPPER SHEATHED MI CABLE. For commercial and industrial applications. Heating cable construction
MI HEATING CABLE COPPER AND HDPE JACKETED COPPER SHEATHED MI CABLE For commercial and industrial applications Heating cable construction Insulation (magnesium oxide) Heating conductor Copper sheath HDPE
More informationPIPE FREEZE PROTECTION AND FLOW MAINTENANCE XL-TRACE SYSTEM
PIPE FREEZE PROTECTION AND FLOW MAINTENANCE XL-TRACE SYSTEM This step-by-step design guide provides the tools necessary to design a Raychem XL-Trace pipe freeze protection or flow maintenance system. For
More informationPrimaLine 3 XT 24V Wet Location LED Tape Light
PrimaLine 3 XT 24V Wet Location LED Tape Light 0.55 in. wide Field cuttable every 2 in. PrimaLine 3 XT wet location tape is a high output, dimmable LED light that supplies the perfect level of brightness
More informationPavement-Mounted Deicing Controller SNOW SWITCH MODEL HSC 24. Installation and Operation Manual
Pavement-Mounted Deicing Controller SNOW SWITCH MODEL HSC 24 MANUAL We Manage Heat Installation and Operation Manual Environmental Technology, Inc. 1850 N Sheridan Street South Bend, Indiana 46628 (574)
More informationINSTALLATION GUIDELINES. Design system and make a layout. For guidance, see attached layout and wiring diagram.
INSTALLATION GUIDELINES 1. Plan Design system and make a layout. For guidance, see attached layout and wiring diagram. Heating elements should be placed on top of the ice and water shield. Between the
More informationProduct Catalog. Just because it s in the floor doesn t mean it s INFLOOR.
Product Catalog Just because it s in the floor doesn t mean it s INFLOOR www.infloor.com TABLE OF CONTENTS Tubing New Style Brass Manifolds & Related Components Current Brass Manifolds & Related Components
More informationSURFACE SNOW MELTING AND ANTI-ICING ELECTROMELT SYSTEM
SURFACE SNOW MELTING AND ANTI-ICING ELECTROMELT SYSTEM This step-by-step design guide provides the tools necessary to design a Raychem ElectroMelt heating cable surface snow melting and anti-icing system.
More informationIntroduction to Heat Trace Cable Systems
Introduction Introduction to Heat Trace Cable Systems Tempco s Heat Trace Cables are used to counteract the effects of heat dissipation from process pipe and equipment through its insulation (if any).
More informationB BASIC HEAT TREATMENT CONSOLE
Maritime Stress PO Box 2898, 30 Estates Road Dartmouth, NS, B2W 4Y2, Canada Toll Free: 1-877-468-1781 Phone: (902) 468-7873 Fax: (902) 468-2304 Website: E-mail: info@maritimestress.com OPERATION MANUAL
More informationTamas Hydronic Panels BTU Snow Melt Submittal Technical Data
Technical Data Job or Customer : Location : Engineer : Complies with Spec Alternate Notes : Contractor : Tamas Rep : Submitted By : Date : Approved By : Date : P.O. Number : Date : Description The Tamas
More informationHeating Cable. Description
ITLS Base Panel Heat Tracing Control Panel for Ordinary Areas 10 VGA Touch Screen HMI 40 Amps/Loop @ 100 600 VAC 6 Loops to 72 Loops NEMA 4 or NEMA 4X Enclosure SCR Control Optional Wireless Temperature
More informationFlexible Heaters. Silicone Rubber Heaters
Rugged, yet thin, lightweight and flexible the use of Watlow silicone rubber heaters is limited only by the imagination. With these heaters, heat can be put where it is needed. In the application process
More informationWaterproof DC Power Supply Converts 110V AC (wall outlet) Power to 12 Volts DC for Lights
Waterproof DC Power Supply Converts 110V AC (wall outlet) Power to 12 Volts DC for Lights Part #: DCP-5 The Larson Electronics DCP-5-12V Waterproof Power Supply converts commonly used 100-277VAC electrical
More informationPipe Freeze Protection Design/Install Guide
Pipe Freeze Protection Design/Install Guide Page 1 of 16 Pipe Freeze Protection Design / Install Guide CONTENTS Introduction Page 3 STEP 1 Information Required Page 4 STEP 2 Design Considerations Page
More informationTwo temperature sensors to protect against freezing and high head pressure in both the indoor evaporator and the outdoor condenser
The ZC 107 Zone Control System was designed to provide the perfect comfort control within the home. At the same time it was designed to make an airconditioning system work more efficiently and thereby
More informationElectric Infrared Heaters TABLE OF CONTENTS. Replacement parts information is available online at store.reverberray.com and in the product manual.
Electric Infrared Heaters Packing List NOTE: All items shown in this booklet are part of our EL and TBAC price code categories. Heaters & Accessories Effective 09/0/6 All orders are subject to acceptance
More informationFV Series Nonmetallic Fluorescent Luminaires For Hazardous and Adverse Locations
Applications For use in hazardous locations defined by the NEC and CEC as Class I, Division 2, Groups A, B, C and D; Class II, Division 2, Groups F and G; Marine Outdoor Salt Water; UL1598A and. As well
More informationCartridge Heaters CARTRIDGE
Hotwatt manufactures a wide range of cartridge heating units for a variety of applications. This size, sheath, leads, terminals, wattage and voltage can be adapted to your heating requirements. Hotwatt
More informationPower-Limiting Cables
Power-Limiting Cables This section provides general design guidelines for power-limiting heat-tracing systems installed on insulated metal pipes. For other applications or design assistance, contact your
More informationType HLT Self-Regulating Heater Cable For use in Ordinary and Hazardous (Classified) Locations
E, I, E, Description Nelson s Type HLT self-regulating heater cable is a parallel circuit electric heater strip. A conductive fluoropolymer core material is extruded over the multi-stranded, nickel-plated,
More information31 Watt Low Voltage LED Fixture for Industrial Lighting - Adjustable Trunnion U-Bracket Mount
31 Watt Low Voltage LED Fixture for Industrial Lighting - Adjustable Trunnion U-Bracket Mount Part #: GAU-31L-LV Page: 1 Buy American Compliant The GAU-31L-LV is a low voltage industrial lighting solution
More informationR2A3. Product Specifications AIR CONDITIONER COMPONENT. For Use With R 22 Refrigerant. 1 1/2 THRU 5 TONS 208 / 230 Volt, 1 phase, 60 Hz
R2A3 Product Specifications For Use With R 22 Refrigerant AIR CONDITIONER COMPONENT 1 1/2 THRU 5 TONS 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Scroll compressors on all models Compressors contain
More informationRevision THERMO TECHNOLOGIES. USDT 2001 Differential Controller. Installation and User s Guide
Revision 8 THERMO TECHNOLOGIES USDT 2001 Differential Controller Installation and User s Guide USDT 2001 DIFFERENTIAL CONTROLLER Installation and User s Guide Table of Contents Introduction General Information
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS VOLT Low Voltage Landscape Lighting VOLT Deck Light Cast Brass VDL-600 and VDL-6000 Series Help Hotline: 1-813-978-3700 Mon-Fri 8am-8pm Sat-Sun 10am - 6pm (EST) Specifications
More informationU Series Heatkace Connection. Chromalox' . NEMA 4X. Entry for 1 Cable. 314" Gonduit Hub Opening
Heatkace Connection Single Entry Connection Box. NEMA 4X. Entry for 1 Cable. 314" Gonduit Hub Opening Multiple Entry Gonnection Box. NEMA 4X. Entry for up to 3 Cables. Power or Tee Gonnection. 314" Conduit
More informationChange the and later A/C & Heat system on the Discovery coach With the multi-zone coleman mach thermostat
Change the 2001.5 and later A/C & Heat system on the Discovery coach With the multi-zone coleman mach thermostat This schematic and wiring diagram is to be used only for single stage heating and single
More information2 0 1 7 D E F E Q U I P M E N T C ATA L O G 608-487-9770 www.hartlandlubes.com TD1 Features & Benefits: Great performance and quiet operation Self priming Stainless steel motor shaft Polypropylene housing
More informationHeating Cables. For Industry Tracing
Heating Cables For Industry Tracing FATI-FFHT-X 1/2 FFHT-X Features Energy efficient, automatically varies its power output in response to pipe temperature changes. Easy to install, can be cut to any length
More informationDIFFERENTIAL THERMOSTAT
DIFFERENTIAL DSD-2 Differential Thermostat. This microcomputer based controller is capable of Testing and Controlling the Temperature Difference between Two remote locations. It reads the temperature from
More informationR4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT
EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 1-1/2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1- phase, 60 Hz R4A3 Product Specifications REFRIGERATION CIRCUIT S Scroll compressors
More informationElectric Actuators Maximum in-lbs
Maximum 14040 in-lbs NEMA 4, 4X, 7 ER- Series Features ISO / DIN valve interface Mounting in any position Thermal overload protection (AC & DC except 12 VDC) Friction brake (standard for AC motors except
More informationR2H3. Product Specifications 3 PHASE HEAT PUMP COMPONENT. For Use With R 22 Refrigerant. 2 1/2 THRU 5 TONS 208 / 230 Volt, 3 phase, 60 Hz
3 PHASE HEAT PUMP COMPONENT 2 1/2 THRU 5 TONS 208 / 230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Scroll compressors on all models Compressors contain proper charge of mineral oil Suction line accumulator
More information12 CB30M SERIES UNITS INCLUDING ECB29 ELECTRIC HEAT
Service Literature Corp. 9711 L7 CB29M CB30M ELITE 10 CB29M and ELITE 12 CB30M SERIES UNITS INCLUDING ECB29 The Elite 10 CB29M and Elite 12 CB30M are high efficiency blower coils. Several models are available
More informationPAB SERIES 3thru6-1/3Ton. Belt Drive 10 SEER CONVERTIBLE SINGLE PACKAGE AIR CONDITIONING UNIT /01
PAB SERIES 3thru6-1/3Ton Belt Drive CONVERTIBLE SINGLE PACKAGE AIR CONDITIONING UNIT 10 SEER SINGLE PACKAGE Electric cooling, self contained for year-round comfort. Systems can be installed on roof top
More informationTHIS MATERIAL IS MEANT TO BE USED ALONG WITH OUR CATALOG IT IS NOT A SUBSTITUTE FOR THE CATALOG
THIS MATERIAL IS MEANT TO BE USED ALONG WITH OUR CATALOG IT IS NOT A SUBSTITUTE FOR THE CATALOG COMPANY OVERVIEW Since 1970, we have been pioneering new developments in heater technology and providing
More informationHow to Select the RE Industrial Actuator Part Number
How to Select the RE Industrial Actuator Part Number RE 10 T F 2 Torque (in-lb) 1.5 150 3 300 6 600 8.5 850 10 1000 15 1500 20 2000 25 2500 30 3000 Reversing Electronic Torque Maximizer (optional) Increases
More informationTamas Hydronic Panels BTU Snow Melt Submittal Technical Data
Technical Data Job or Customer : Location : Engineer : Complies with Spec Alternate Notes : Contractor : Tamas Rep : Submitted By : Date : Approved By : Date : P.O. Number : Date : Description The Tamas
More informationHeating Cable. Construction
Mineral Insulated High Temperature A C Constant Wattage Series Resistance Heating Cable Sets Process Temperature Maintenance to F (593 C) Maximum Exposure Temperature 4 F (76 C) (Power Off) Corrosion Resistant
More informationAIR COOLED CHILLERS WATER COOLED CHILLERS
AIR COOLED CHILLERS WATER COOLED CHILLERS STANDARD UNIT SPECIFICATIONS OF COMMERCIAL AIR COOLED CHILLERS General Description & Assembly Air Cooled Chillers are commercial packaged systems complete with
More informationFrost protection for pipes. 16 Technical handbook. Thermostat with line or ambient temperature sensor
Frozen pipes can be a costly problem. When pipes are exposed to subzero temperatures they can burst, leading to considerable damage and disruption. The Raychem frost protection system provides an efficient
More informationH900 WinterGard Power Connection Kit with End Seal Installation Instructions
H900 WinterGard Power Connection Kit with End Seal Installation Instructions Power connection for H311, H611, and H621 Power connection for H612 and H622 Description The WinterGard power connection kit
More informationHeating Cable. Construction
MI Mineral Insulated High Temperature A B C Constant Wattage Series Resistance Heating Cable Sets Process Temperature Maintenance to 1112 F (600 C) Maximum Exposure Temperature 1200 F (648 C) (Power Off)
More informationthe Interactive Catalog
Interactive Catalog Supplements Catalog PDFs If you need detailed product information, or help choosing the right product for your application, see our Interactive Catalog Use the Interactive Catalog to
More informationCX1 ProVector Explosion-Proof Heaters
Explosion-Proof Heaters For hazardous locations heating, rely on the for the most dependable, troublefree service available. CCI Thermal Technologies Inc. manufactures explosion-proof air heaters to satisfy
More informationwiring diagrams SINGLE PACKAGE ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS
wiring diagrams SINGLE PACKAGE ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS 580F 036-150 3 to 12 1 / 2 Tons Cancels: New WD 580F.36.1 10/15/00 *Low NOx/California compliant units. DIAGRAM INDEX UNIT LABEL
More informationSelf-regulating heating cables with a non-heating service cable
N144/R02(22.08.18) Self-regulating heating cables with a non-heating service cable ELSR-M-15-2-BO ELSR-N--2-AO ELSR-N-30-2-AO GENERAL CONDITIONS The connector which connects the cold end and the heating
More informationPLED Ultra Low Holding Current Series
RoHS Description Agency Approvals This PLED ultra-low holding current series exhibits a low holding current parameter that makes it compatible with LED lighting strings. The series provide a switching
More informationHEAT TRACE CABLE. Introduction to Heat Trace Cable Systems Mineral Insulated Heat Trace Cable Non-Metallic Sheath
Introduction to Heat Trace Cable Systems...6-2 Mineral Insulated Heat Trace Cable...6-2 Non-Metallic Sheath Heat Trace Cable...6-2 Installation Details...6-4 Engineering Guide for Mineral Insulated Cable...6-5
More informationBL-40 UNIVERSAL CIRCUIT BOARD REPLACEMENT KIT
ALLIED INNOVATIS, LLC Manufacturing the Product Lines of Len Gordon 7215 Bermuda Rd Las Vegas NV 89119-4304 BL-40 UNIVERSAL CIRCUIT BOARD REPLACEMENT KIT IMPORTANT INSTALLATI INSTRUCTIS - PLEASE READ!
More informationGE 8000-Line Motor Control Centers
GE 8000-Line -1 ENCLOSURE TYPES TYPE 1 General Purpose, Indoor Intended for use indoors, primarily to prevent accidental contact of personnel with the enclosed equipment, in areas where unusual service
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS VOLT Low Voltage Landscape Lighting VOLT Brass Bunker Step Light VHS-63X-4-BBZ Help Hotline: 1-813-978-3700 Mon-Fri 8am-8pm Sat-Sun 10am - 6pm (EST) Specifications and product
More informationHeating Cable. Description
Single Entry Power Connection Kit NEMA 4X Entry for 1 Cable 3/4 Conduit Hub Opening Lighted or Non-Lighted Multiple Entry Connection Box NEMA 4X Entry for up to 3 Cables Power, Splice or Tee Connection
More informationMaximum Line Resistance vs. Length of Wire Max. Loop Resistance. Max. Wire Run 18AWG 7x26 Stranded (ft)
. W Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies /" to " NPT / 3/ / 5/ 5/3 Features Molded one-piece solenoid with highly efficient solenoid cartridge and special low wattage coil Increased
More informationInstallation Manual GT500 GT500R RAB
Installation Manual GT500 GT500R RAB How Does Gotcha Work? Gotcha s infrared sensor sees small temperature changes caused by the motion of people or cars within its protection zone and turns on lights
More informationF200 - Ground Fault Equipment Protectors Complete protection of your equipment
F200 - Ground Fault Equipment Protectors Complete protection of your equipment 2 F200 - Ground Fault Equipment Protectors What is a ground fault and why it is important to detect it A better understanding
More informationFLAT/VERTICAL TYPE HIGH POWER BIFURCATED CONTACT
FLAT/VERTICAL TYPE HIGH POWER BIFURCATED CONTACT NC NC RELAYS Flat type Flat type (PC board) (PC board) FEATURES 1. Compact, slim design Use of high-performance flat electromagnetic design achieves 10.9
More informationSnow Melt EN_US_2014_V2.indb 171 2/7/ :18:52 AM
171 Viega snow melting systems are complete hydronic solutions for residential, commercial and industrial applications. All it takes is ViegaPEX Barrier tubing installed in a concrete slab and the proper
More informationCITY AND COUNTY OF DENVER DEPARTMENT OF PUBLIC WORKS STATEMENT OF QUANTITIES. Item No. Description Estimated Quantity
202-00019 Removal of Inlet 15 EA 202-00035 Removal of Pipe 121 LF 202-00200 Removal of Sidewalk 1,057 SY 202-00203 Removal of Curb and Gutter 2,142 LF 202-00206 Removal of Concrete Curb Ramp 320 SY 202-00207
More informationBLAZE 12V LED TAPE LIGHT
DRY LOCATION BLAZE 12V LED TAPE LIGHT High Brightness Available in 8+ CRI 16.4 ft. maximum run UL Listed & R/C SAM Manual Suitable for closet use 5-Year limited warranty SUITABLE FOR CLOSET USE DIMMABLE
More informationProduct Specifications EFFICIENT 13 SEER AIR CONDITIONER
EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 1-1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Copeland Scrollt compressors on all
More information