Medium-voltage AC Drive WIN-HV Series

Size: px
Start display at page:

Download "Medium-voltage AC Drive WIN-HV Series"

Transcription

1 Medium-voltage AC Drive WIN-HV Series SHENZHEN WINNER S&T CO., LTD.

2 SHENZHEN WINNER S&T CO., LTD. Trademark Definition 1. The pattern represents current; W is the initial of WINNER,which simply, vividly and intuitively expresses the attributes to another sine wave. The beautiful and flowing curve of W signifies the vitality of the company and the progress from one victory to another victory. It inspires the employee to enhance the competition of the company and stick to the conception of harmony, endeavour, honesty, win-win 2. The balance of the soaraway letter W with the ellipse denotes that the company innovates incessantly, always seeks for greater perfection in quality, and the company will take off through strategy of brand promotion. 3. the brand is obvious, it has distinct brand conception The color mainly adopts red and dark blue. The red signifies fervency, solemnness and splendor. Dark blue represents broadness, profundity and steadiness.

3 Harmony Endeavour Honesty Win-win

4 Technology Saves Energy Wisdom Creates Future

5 SHENZHEN WINNER S&T CO., LTD. SHENZHEN WINNER S&T CO., LTD. Governing unit of inverter branch of China Electric Equipment Industrial Association Shenzhen high and new technology enterprise 4 Established in Mar., 2004, Shenzhen WINNER S&T Co.,LTD. is a High- New-technology enterprise titled by the government. It is the council member of the inverter branch of china electric appliance industrial association. All the company s software and hardware were developed by itself, and all the products bears its own intellectual property. Occupying 5 floors of office and production area with 7000 square meters and anual production capacity of units, Shenzhen WINNER has become the mainstream of inverter suppliers in china and it is the first company which offers medium-voltage inverter in Shenzhen. Since established, WINNER successively launched a series first-class inverters with different control solution like, V/F control, Vector control; different operation modes, like the second quadrant operation, the fourth quadrant operation.; different mail-loop topology structure, like bi-level, tri-level, multi-level. Besides, the company brought out some energysaving products which is based on inverting technology. Based on strong technology, strict production management, reliable product quality, winner's product entered the field of power supply, iron and stell, metallurgy, mines, oil, chemistry, construction,etc. Stick to the principle of self-development and innovation, taking the route of brand building, by virtue of in-depth research of inverting technology and accurate judgment over the future of the industry, WINNER is kept developing fast and steadily. WINNER's Milestone Mar. 2004, Shenzhen WINNER was registered and established with its objective, to develop and manufacture inverters and energy-saving equipment with first-class technology and performance. June, 2004, WIN-9G series of inverters was launched and obtained wide approbate from customers June, 2005, WIN-9G series was approved by CE. July, 2005, WINNER HV Inverter project was started. Sep. 2005, WIN-9GF series was developed successfully. Nov. 2005, WIN-9GV was developed and launched. Aug., 2006, WINNER passed UKAS."ISO9001" 2006, WIN-9EV, WIN-9L, WIN-9U series inverters was developed successively, and the company fulfills the products'specialization and diversification. Dec.2006, WINNER's Hi-voltage products successfully passed the strict test executed by electric drive design institute of Tianjin, and WINNERs became the first company in Shenzhen, which owns selfdeveloped medium, commercial voltage inverters and other energy-saving products. Mar., 2007, Honored with the tile of "Shenzhen high-new technology enterprise" June.,2007,awarded with the certificate of "owning independent intellectual property" July, 2007, the factory moved to building 3, Antongda industry zone, and the operation area was expanded to be 7000 square meters. Aug., 2007, becoming the first council member of inverter branch of china electric appliance industry association. Sep. 2007, WIN-VA, WIN-VB, WIN-VC full series of vector control inverters were successfully developed, and it signifies winner smoothly achieved the products updating and upgrading. In the latter half of 2007, 17 units of hi-voltage products successively began to serve in coal steam-electric plant, steel plant, chemistry plant, cement plant. And winner became the mains supplier of inverter. Dec. 2007, winner s developing strength and results are approbated by Shenzhen Science and Technology Bureau. And winner got a reward from the government. May, 2008, winner was titled with "one of the top 10 brands of hi-voltage inverter of 2007" by HC360. June, 2008, WINNER was elected as one of the top ten satisfactory brands in 2007 by ELECTRIC AGE. June,2009, WINNER R&D team has been greatly strengthened again. Since then, WINNER is able to compete with the top brands in the world from all sides.

6 Technology Saves Energy Wisdom Creates Future WINNER Conception Business Principle To attract customers by credit, to win customers by quality, to serve customs by products. R&D Principle Seeking increasing perfection and catching up the world s latest technology. Market Principle To strictly execute the regulation of customer notification and registration, and protect the interest of our distributors and agents. To periodically hold technical training activities for our distributors and agents. To periodically hold partner talkfest, and establish sound and close cooperating relationship. 5 Quality Principle To improve quality by advance management, to satisfy customers by aesthetic ideology. Service Principle To feedback to the customers by high efficiency/to influence the customers by professional competence, To impress the customer by sincerity, to move the customer by satisfaction. Value Conception To naturalize the earth, to save energy for motherland, to deepen the welfare for employees, to seek development opportunities for the enterprise.

7 SHENZHEN WINNER S&T CO., LTD. Technology Saves Energy Wisdom Creates Future WIN-HV Series WINNER Medium-Voltage Products Prominent Feature 6 Full Range Of LV And MV Frequency Inverter In WINNER.

8 Technology Saves Energy Wisdom Creates Future WIN-HV Series Medium-Voltage Frequency Inverter WIN-HV T V 315~1250kW WIN-HV T V 315~5000kW WIN-HV T V 315~8000kW 7 WINNER Medium-Voltage Products Prominent Feature: Years of large current-driving technologies enable the company to offer the products with power up to 8000 kw Unique low inductance bus structure ensures more stable operation of power unit The distinctive design of the ventilation and cooling components layout provide the inverter with more reliable operation Non-disturbance two-way switching capability between gird and inverted frequency ensures the equipment s continuous operation The control cabinet at the low potential end of the host machine maximally distinguishes electromagnetic interference Outstanding low harmonic content level protect the grid from pollution.

9 SHENZHEN WINNER S&T CO., LTD. Product's Introduction The WINNER WIN-HV series medium-voltage frequency inverter designed and manufactured by Shenzhen Winner has prominent performance and high reliability. It is of AC-DC-AC voltage type inverter with main circuit of multi-level topology circuit. The control mode adopts SPWM technology. And the input uses isolated transformer of multiple technology, while the output is fulfilled by the solution of phase-shifting tandem multi-unit and medium-voltage to medium-voltage direct conversion. Many years of technical experience enabled WINNER and its staff to have developed inverters with low harmonic content, which is in a leading level in domestic. Perfect output voltage sine wave provides the inverter with stability of motor s operation during the whole speed regulation range. The low input current harmonics almost has no any disturbance to the grid and this ensures the operation reliability of the surrounding electric equipments. This series inverter can drive and regulate the medium-voltage motor in almost all kinds of application area. The speed regulation is smooth, and the efficiency and power factor is enviable. In particular, nowadays the world is in short of energy. WINNER inverter can bring great economic effect when used for blowers and pumps. 8 This series inverter consists of three main parts, transformer cabinet is on the left, and power unit cabinet is in the middle, while control cabinet is on the right. To improve the stability of the control circuit and to make the debugging more convenient, the control cabinet door was put on the right of the machine. This series product adopts cabinet structure with forced air cooling. And the big capacity machine adopts the cooling mode of water-cooled, air-closed circulation. The wiring terminal of input and output of the complete machine was placed on the lower left back. It is easy for connection It is commonly recognized that market develops based on good service system. In addition to trusting in such conception, Shenzhen Winner S&T Co., Ltd adheres to focus on R&D of frequency conversion technique, with an aim of producing high quality inverters and bringing more benefits to its clients.

10 Main Features of WIN-HV Series Inverter Technology Saves Energy Wisdom Creates Future Based on the SPWM technology, transformer isolation design and solution of power unit connection in series, WIN-HV series inverter (hereafter refered as the inverter) can realize direct conversion from medium voltage input to medium voltage output. Unit W1 Unit V1 Unit U1 Unit W2 Unit V2 Unit U2 Unit Vn Unit Un Unit Wn MCB Signal panel User inter face PLC DCS System Analog signal external control signal No particular requirement on the motor to be driven. Total system efficiency hits as high as 96%. Friendly user interface: The inverter has Windows 2000 operation system, large-sized true color LCD and expedite touch screen, which makes operation more convenient. What s more, the inverter can store more than 20 suits of parameter settings, and automatically memorize all the operating information for any real-time reference. Flexible control mode: local control by touch screen; remote control by I/O of built-in PLC, and host control by connection between RS485 and DCS system. The pre-charged circuit of the high-power inverter eliminates surge current at start. It is suitable to all the lowcapacity grid and peripheral devices. 9 WIN-HV speed control system diagram Two-way control power supply ensures the system s normal operation. Less harmonic content. The input terminal of the inverter adopts the phase shifting transformer superposition technology, which can efficiently suppress harmonic content of input current. And the output terminal adopts the power unit (n=3~9 units) connection in series technology, which guarantees the output waveform more close to the sine wave. At the line side, the system is of uncontrolled mode rectifying input with 6n pulse, i.e. 18 (T30), 36 pulse(t60),54 pulse(t100). While at the load side, the system is of (2n+1) levels, i.e,7 levels(t30), 13 levels(t60),19 levels(t100). Both the input and output waveform approach sine wave. Input current waveform sketch Output voltage waveform sketch Output current waveform sketch Perfect self-analysis system can online monitor the inverter s operating status. It can automatically introduce protective measures and record the operating parameters in the event of fault. Various protective measures to the input terminal, output terminal, voltage,current and temperature provide the inverter with perfect self-analysis function and strong processing capability. Automatic bypass function can online cut off the faulty power unit and ensure three- phase voltage output remains symmetrical and current output maintains balanced, so as to maximumly reduce the probability of outage. Optional non-interference automatic bypass function can perform automatic switch between the industrial frequency and inverted frequency. In case that the inverter breaks down, the bypass system will automatically switch the motor to mains supply, to guarantee the system maintains normal operation. No need to install noise filter. The input and output harmonic content can both meet the requirements of IEC :2002 No need to install power factor compensation device. The power factor exceeds 0.97 at rated load in the range of normal speed regulation. Power unit circuit elementary diagram

11 SHENZHEN WINNER S&T CO., LTD. System constitution Power unit Each phase output consists of several serially-connected power units. The number of power units varies according to different output voltage. Please refer to the fig. below. Inverter rated voltage No. of seriallyconnected power units (n) Rated voltage of power unit (V) Output phase voltage (V) Level no. per phase voltage Output voltage (kv) Level no. per output voltage T T T Different cooling modes of power unit

12 Technology Saves Energy Wisdom Creates Future The power unit can be also called a typical single-phase inverter with three-phase input and single-phase output based on sine wave PWM. Q1 Q2 Q3 Q4 Or K 11 L1 L2 Rectifying Circuit Filter Inverting Circuit Bypass Circuit sketch map of power unit Radiator Serially-connected copper bar Set screw Fast fuse Three-phase input cable Communication fibre

13 SHENZHEN WINNER S&T CO., LTD. Prominent main circuit arrangement 12 WIN-HV inverter consists of three separated cabinets: transformer cabinet, power unit cabinet and control cabinet, and all the strong current circuit, week current circuit, main circuit and control circuit are arranged in a separated cabinet. That efficiently suppresses interference and guarantees stable operation of the inverter. Reasonable deployment of transformers and cooling fans, and directly-visible temperature indication The precharging device eliminates surge current at start Interchangeable power units. That makes maintenance and repair more convenient. The cooling fans are designed to lie on the top of the cabinets, simplifying air pipeline connection. Able to provide large-capacity load with hermetically water-circulating cooling mode. No need to change the filter net, and greatly improve reliability of the inverter. Automatic bypass function can online cut off the faulty power unit and the inverter will not stop but go on running with a decreased frequency. That enhances the reliability of the system. Transformer cabinet Power unit cabinet

14 电源指示运行指示故障显示 远程 / 本地 工频投切 系统复位 高压分断 Technology Saves Energy Wisdom Creates Future Control cabinet The control cabinet lies at the side of the inverter s low potential, which can efficiently suppress electromagnetic interference. Optoelectronic isolation The built-in PLC can satisfy various digital and analog signal processing requirements. High quality components and well-designed wiring guarantee stability and reliability of the inverter 13 Ventilation and Heat Dissipation Layout The transformer cabinet and the power unit cabinet both have forced cooling fans and unattached ventilation tunnels, ensuring stability of the inverter. Adopts German EBM fan heat dissipation system, efficiently preventing temperature soaring 非专业人员严禁触碰操作触摸屏

15 SHENZHEN WINNER S&T CO., LTD. Power Unit Bypass Function This function efficiently guarantees continuous operation of the motor. On condition that any power unit breaks down, the system will automatically bypass this unit and meanwhile, bypass another two power units with the same level. The system will maintain operation but with a lower rated frequency. The system can keep operation even when three power units have been bypassed at the same time. No influence on the system if it previously runs with a frequency that is lower than the declined rated frequency. The system can enable automatically the bypass function Rated voltage of the inverter the number of serially-connected power unit in each phase declined margin when one power unit breaks down Max. operating frequency on the bypass condition T HZ 14 T HZ T HZ Inverter Bypass Function Principle of manual bypass QS2, QS3 mechanical interlock. The bypass system is recommended to be added to guarantee continuous operation of the motor. When switching to mains supply, please pay attention to the grid capacity and start mode, so as to suppress inrush current. Please start the speed tracking function when switching to mains supply QS3 MV Power Supply QF1 QS1 WIN-HV HV Inverter QS2 M MV Motor Manual bypass diagram Principle of automatic bypass KM2, KM3 electrical interlock, please refer to the fig. below. KM3 MV Power Supply QF1 DXN1 KM1 QS1 FM WIN-HV HV Inverter KM2 QS2 M MV Motor Automatic bypass diagram

16 Technology Saves Energy Wisdom Creates Future Operation interface 12-inch true color LCD touch screen and Windows 2000 operation system provide visualized parameter display and convenient operation. The operating parameters including frequency setting, frequency output, output voltage, output current, speed, output pressure, etc. are all displayed in the user interface, which makes the user to browse more easily. And the RUN/STOP operation becomes more convenient. Parameter setting mainly involves the inverter-related operating parameters such as voltage, current, frequency, time, bypass levels, and the motor-related parameters such as motor speed, power output, voltage, current, overload level. In this sub-interface, users can perform parameter copy & use, and change the initial settings at factory. Please refer to the pictures right. Enter the sub-interface through the main interface to perform function setting, parameters setting, copy& use, operation record and fault record browse. Simplify fault monitoring and analysis. Function setting includes control status (adjustment/ operation), operation mode (closed-loop /open-loop), system bypass, interface lock-up, given mode, and host control, etc. 15 Main circuit power supply AC 3Ф 50~60Hz 380V~10000V A B C U V W M High-voltage AC motor Operation Stop Forward/reverse Fault rest. Exterior fault bypass switch Multi-step speed Use definition Manual/automatic Exterior analog frequency 0~5V set value 4~20mA set value Analog voltage feedback Analog voltage feedback A nalog common terminal RUN STOP F/R RST ERR BO X1~X3 X4~X7 X8 P24 VG IG VF IF GND G WIN-HV Human-machine interface BOFF BEN BON LO TA1 TA2 TA3 TA4 TA5 TA6 TA7 COM FM0 FM1 VM0 VM1 IM0 IM1 GM SG+ SG- C1 C2 C3 High-voltage analysis Bypass permission Bypass switch Multi-function relay output terminal Operation minor fault Stop Fault Remote/local High-voltage power-up Programmable analog output terminal 0~10V } Alternative 4~20mA 0~10V } Alternative 4~20mA 0~10V } Alternative 4~20mA RS-485 To connect host machine.

17 SHENZHEN WINNER S&T CO., LTD. 16 The inverter will be produced with input current rating & input voltage rating at the request of users. There are two buttons and two switches on the front panel of the control cabinet. The button of switching to mains supply is used when the inverter breaks down. It can perform industrial frequency power supply/automatic industrial frequency bypass switch by pressing the button. The button of System reset is used for parameter setting or to reset the system at non-essential fault occurring. On condition of emergency stop required, press the button of Medium voltage disconnection to cut off output, then the inverter will coast to stop. The bottom of Remote/Local can perform remote control and local control switch. In the mode of local control, users can perform inverter speed control, frequency up and down, stop, reset, etc. on the touch screen of the inverter. While in the mode of remote control, users can control the inverter through the DCS system or other remote control station. Through RS-485 communicate port, can realize communication with host machine or control system. It conforms to MODBUS Protocol. Frequency given mode: (1) manual given mode through user interface, (2) terminal analog given mode. In the mode of terminal analog given, VG and IG correspond to voltage given signal and current given signal respectively. Through its noninterference bypass function, the inverter can be automatically self-bypassed on condition of major fault occurring, and switch the motor to the mains supply, which guarantees normal operation of the system. It can realize manual bypass through the three output terminals medium voltage disconnection, bypass permit and bypass connection. Model definition WIN-HV - T - System category Application code-heavy load, pumps, etc Three-phase rated output voltage (kv /10) Rated output current (A) Series No. of WINNER-branded medium voltage

18 Technology Saves Energy Wisdom Creates Future Basic parameters Classification Parameters Range Unit Increment Factory default Reference frequency 40.0~50.0 Hz 0.1Hz 50 Reference voltage 1500~10000 V 1V variable Maximum frequency 0~60 Hz 0.1Hz 50 upper limit frequency 0~60 Hz 0.1Hz 51 lower limit frequency 0~60 Hz 0.1Hz 3.0 Drive parameters Function parameters parameters status parameters Starting frequency 0~5 Hz 0.1Hz 0.5 acceleration time 1~255 4s 1 15 deceleration time 1~255 4s 1 15 torque boost 0~ Overload multiple 10~150 % unit bypass level 0~2 1 1 frequency inverter address 0~ host input selection With, without without host control selection with,without without control status open loop or closed loop open loop operating mode Local or remote local input mode digital,analog,multi-step speed digital analog input option 0~5V/0~20mA V/mA 0~5V Analog output option(3 ways) As per manual Bypass option with,without without Motor rated power 0~8000 kw 1kW As per specification motor rated current 0~600 A 0.1A As per specification Motor over load multiple 120~150 % Number of motor poles 2~10 \ 1 4 Motor rated speed 180~3600 Rpm Input frequency 0~50 Hz 0.1Hz operation speed Rpm Operating frequency 0~51 Hz 0.1Hz output current A 0.1A Output voltage V Output power kw Continuous operating time h 0.1h 17

19 电源指示运行指示故障显示 远程 / 本地工频投切系统复位高压分析 SHENZHEN WINNER S&T CO., LTD. Technical Specification and installation dimension 18 Specifications WIN-HV_T Capacity of drive (kva) Power of adaptive motor (kw) Rated output current (A) Output Number of serial units per phase 5 Outline dimensions (W H D) Weight (Kg) 3500~ ~ ~8550 Specifications WIN-HV_T Capacity of drive (kva) Power of adaptive motor (kw) Rated output current (A) Output Number of serial units per phase 6 Outline dimensions (W H D) Weight (Kg) 2500~ ~ ~ ~ ~14400 Specifications WIN-HV_T Capacity of drive (kva) Power of adaptive motor (kw) Output Rated output current (A) Outline dimensions (W H D) Weight (kg) 3000~ ~ ~ ~ ~22300 Number of serial units per phase 9 Input frequency 50/60Hz+3% Input voltage T30: 3kV, T60: 6kV, T100: 10kV(-20% ~ +15%) Power supply Allowed power failure time 100ms Input power factor > 0.97 (under a rated load) Efficiency > 96% (under a rated load); > 98% for the drive part Control mode PWM, phase-shifting, wave-overlaping, power cells in serial connection,ac-dc-ac,direct medium voltage output,. Output frequency 0 ~ 50Hz Precision of output frequency 0.1Hz 120% (1 minute), 150% (2s), 160% (immediate protection); heavy-load model: 150% (1 minute), 180% (2s), Overload capability 200% (immediate protection) Control features Acceleration and deceleration time 4 ~ 1200s Analog input 0~5V, 0~20mA, 4~20mA (2 ports) Analog output 0~10V, 4~20mA voltage, current and frequency optional (3 channels) output is for 5 variables Analog feedback 0~5V, 4~20mA (2 ports) Host communication Isolation RS485 interface Boolean input/output 14-channel/10-channel Overcurrent, overload, short-circuit, 3-phase current imbalance, Protection function transient power failure, input/output phase loss, overvoltage, undervoltage, body overheat, shutdown caused by external fault, automatic bypass of power unit H Operation environment temperature 0 C ~ + 40 C Environment Storage and transport temperature -40 C ~ +70 C Cooling mode Compulsory air cooling Environment humidity < 90% (no condensate) Altitude < 1,000m Protection grade IP30 W D

20 Technology Saves Energy Wisdom Creates Future WIN-HV inverter speed adjustment principle and applications The load characteristics of the vane-type pump, fan and compressor are all of square torque type, which means the torque on the axis is proportional to the square of the motor speed. The pump and fan conform to the similarity theorem on condition of geometric similarity, movement similarity and power similarity. Taking a fan (or pump) as an example, if its speed is to be adjusted while the consistency of the transmitted liquid remains constant, its performance parameters will change following the proportion theorem, the flow quantity is proportional to the speed; the pumping head is proportional to the square of the speed; and the axis power is proportional to the cube of the speed. But in actual operation, it is inaccurate to compute the speed control range and energy saving efficiency simply by the said proportion theorem due to different system parameters and operating status Energy saving principle of pumps: Different from fans, the static pumping head of pumps Hst 0. The outlet pressure (pumping head) of pumps is required to maintain constant in most occasions. The pump s energy saving principle can be represented by the diagram 2. Fig.2 Energy saving elementary diagram of pumps When decreasing the flow quantity from Q1 to Q2 by the valve, the pump speed maintains its rated speed N1, but the pipe network resistance curve (1) will change to the curve (2), leading the working intersection A to change to B. At this time, the consumed axis power can be represented by the area of H1BOQ2, almost the same to that of H2AOQ1, resulting in huge energy to be wasted. When the inverter is installed, it can decrease the pump speed from N1 to N2 with the pipe network resistance curve (1) being unchanged, so the working intersection A transfers to C. At this time, the consumed axis power can be represented by the area of H3COQ2. Compared with H1BOQ2, it is easy to find out that the inverter has prominent energy-saving capacity.

21 SHENZHEN WINNER S&T CO., LTD. 1. Energy saving principle of fans: As the fan s static pressure Pst=0, its energy saving principle can be represented by the diagram In the diagram 1, the curve (1) represents the wind pressure and wind quantity characteristics curve (P-Q) at rated speed N1. The curve (2) is the pipe network resistance characteristics curve when the air valve is widely open. The intersection A of the curve (1) and (2) indicates the point at which the motor runs with the highest efficiency. At this time, the wind pressure is assumed as P2, the wind quantity is Q1, and the axis power N1=k*Q1*P2, which can be represented by the area of AP2OQ1. On condition that the wind quantity is to be decreased from Q1 to Q2 according to production requirements: If adjusting the wind quantity by the valve, it will increase resistance of the pipe network, resulting in the pipe network resistance curve to change to the curve (3), and the intersection A change to B. At this time, the wind press is assumed as P1 and wind quantity is Q2, so the axis power N2 = k*q2*p1, which can be represented by the area of BP1OQ2. Compared with AP2OQ1, it is easy to find out that the axis power decreases just a bit. When adopting the inverter to conduct speed adjustment, the fan speed will reduce from N1 to N2. As the fan s static pressure Pst=0, conforming to the similarity theorem, the wind pressure and wind quantity characteristics curve(p-q) at the speed N2 can be represented by the curve (4), which converges the curve (2) at point C. At this time, the wind pressure is assumed as P3 and wind quantity is Q2, so the axis power N3=K*Q2*P3, which can be represented by the area of CP3OQ2. It is easy to draw a conclusion that N3 decreases steeply due to hefty decline of wind pressure. Fig. 1 Energy saving elementary diagram of fans Compared with the valve control mode, the inverter can help save huge energy. The saved axis power N=K*(P1-P3)*Q2, which can be represented by the area of P1BCP3.

22 Technology Saves Energy Wisdom Creates Future Application cases The power plant owns a generator with annual production capacity of 200MW. It was installed with two 1250kW/6kV induced draft fans. The following diagram shows energy-saving efficiency after WIN-HV inverter is installed Before Reformation After Reformation Machine load (MW) Total power of the Motor load ratio of the Total power of the induced draft fans(kw) induced draft fans (%) induced draft fans(kw) Energy saving ratio (%) In most of the power plants, the induced draft fan of boiler furnace commonly runs at a constant speed with power frequency. It is wasting quite lots of electricity in the process of adjusting the wind quantity via the valve. The 200WM generator usually runs with peak shaving, with huge valley-to-peak difference. When WIN-HV inverter is installed, the induced draft fans get access to realize speed adjustment, as well as wind pressure and wind quantity control no matter whether the valve is open or not. Accordingly, WIN-HV inverter is able to help the power producer save energy and cut cost, with energy-saving rate of 20%~70%. 21 Indirect economic benefits Strengthen reliability of the equipments The installation of WIN-HV inverter realizes soft starting in a real sense,eliminates huge surge current and mechanical wear abrasion so as to prolong the life of the equipments. Low-speed operation reduces the fan s vibration and the bearing s wearing, thence the reliability of the equipment is improved. Reduce maintenance and repair cost WIN-HV inverter can help the user reduce maintenance and repair cost as it eliminates huge surge current and mechanical wear abrasion. Enhance automazation level WIN-HV inverter is equipped with several external signal and computer interfaces, which enable the inverter convenient to connect with the control system PLC, DCS &FCS, communication system, energy management system and other management system. It greatly enhances the machines roboticized control and management level. Relieve labour intensity On condition of the load changed, it is very inconvenient to adjust the wind quantity by changing the valve opening. And this control mode has poor linearity and high fault rate. In contrast, when adopting WIN-HV inverter, it can adjust the speed of the fan by regulating the fan s motor frequency. It is much easier to operate, with perfect linearity and control sensitivity.

23 SHENZHEN WINNER S&T CO., LTD. Application area WIN-HV medium voltage inverter has been widely used in the fields of power plant, iron and steel, oil, mine, construction, etc for the medium-voltage motor s speed regulation, energy saving, soft starting and intelligent control. 22 Thermal power plant: Coal pulverize, ventilator, induced draft blower, powder extraction blower, circulating water pump, feed water pump, condensate extraction pump, heat water supply pump, heat back water pump, etc Iron and steel plant: Feed water pump, dust exhaust fan, induced draft blower, oxygen generator, Mine: Slurry pump, ventilator Oilfield: Water flood pump, crude oil pump Chemical plant: Compressor, blower, circulating water pump Water supply work and wastewater treatment plant: In-take pump, feed water supply pump, self-fractionating pump, sewage pump, Cement plant and ceram plant: Grinding machine, pump, induced draft blower, dust exhaust fan, etc Other field: Pumps and fans used in the industry of medicine, paper making and food.

24 Technology Saves Energy Wisdom Creates Future Quality Management System Quality policy To improve quality by advanced management, to satisfy customers by aesthetic ideology. Quality management To strictly control the quality according to ISO 9001:200 Quality assurance To produce the goods strictly according to the national standards, GB/T ,GB ,GB/T ,GB/ T Market management To strictly execute the regulation of customer notification and registration, and protect the interest of our distributors and agents. To periodically hold technical training activities for our distributors and agents. To periodically hold partner talkfest, and establish sound and close cooperating relationship. After service Complaint disposal: reply in written form. Service response time: within 24 hours in the area where there is a service center. Other area: 48 hours. After service line:

25 SHENZHEN WINNER S&T CO., LTD. Guarantee In the condition that the breakdown of the products is caused by the product itself, as from the delivery date: For domestic customers: the goods with breakdown can be returned within 1 month without charge, can be replaced within 3 months without charge, can be repaired within 12 months without charge. For domestic customers: we offer free parts for products which break down within 12 months. All the products from WINNER enjoy lifelong paid service. 24

26 SHENZHEN WINNER S&T CO., LTD. Address: Building 3, AntongdaIndustrial Park, No.1 Lucian Road, Baoan District, Shenzhen, China Web: This catalog is subject to change without notice WINNERS-MI /05/14

Industrial PFC UPS System

Industrial PFC UPS System Based on Statron s leading A.T.I.S. (Advanced Technology Industrial System) platform, the S3000 range is a true-industrial UPS system using the latest Power Factor Corrected (PFC) IGBT rectifier technology.

More information

Rongxin Power Electronic Co.,Ltd. VFS VARIABLE FREQUENCY STARTER.

Rongxin Power Electronic Co.,Ltd. VFS VARIABLE FREQUENCY STARTER. Rongxin Power Electronic Co.,Ltd. VFS VARIABLE FREQUENCY STARTER www.rxpe.co.uk VFS VARIABLE FREQUENCY STARTER 01 the biggest 66kV/10000kVA high voltage testing center in China 02 advanced full automatically

More information

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting POWER+ PREMIUM CBS CENTRALIZED Battery System BS-EN-50171 Emergency electrical installations Electric power systems Emergency lighting Escape lighting POWER+ PREMIUM CBS 10KVA-40KVA The systems running

More information

UPS5000-E (25-75 kva) Series

UPS5000-E (25-75 kva) Series Battery Integrated Uninterruptible Power System UPS5000-E (25-75 kva) Series HUAWEI TECHNOLOGIES CO., LTD. CONTENTS 02 Solution Overview 03 Customer Benefits 09 System Architecture and Key Components 12

More information

Liebert. FP 50Z kva

Liebert. FP 50Z kva Liebert FP 50Z 5 250 kva Enabling Tomorrow s CRITICAL EDGE INFRASTRUCTURE We helped some of the largest names in the industry bring new capacity online faster and at a lower cost when search and social

More information

TECHNICAL DATA SHEET KVA UPS Systemss

TECHNICAL DATA SHEET KVA UPS Systemss Återförsäljare: Tre Röda AB TillingeHagby 7-745 94 ENKÖPING Tel: 08-560 200 22 e-post: info@treroda.nu http: www.treroda.nu When the INSIDE is important make the OUTSIDE Cannon TECHNICAL DATA SHEET 400-500-600-800

More information

CENTAURI ENERGY SERVER TECHNICAL DATA kw POWER

CENTAURI ENERGY SERVER TECHNICAL DATA kw POWER Chassis Inverter power Rated input Rated output Battery pack Safeties Environment Others Input Voltage Lower Limit Input Voltage Upper Limit Power Input Current Output Voltage Output accuracy Transient

More information

D Series: UPS UPTO - 300KVA - Three / Three Phase

D Series: UPS UPTO - 300KVA - Three / Three Phase D Series: UPS UPTO - 300KVA - Three / Three Phase All in one D Series UPS High Power UPS Systems, Now in India Properties : Standard Properties 1GBT rectifier inverter technology Input power factor correction

More information

MX1S Matrix Converter

MX1S Matrix Converter MX1S Matrix Converter Energy-Saving Medium-Voltage Drive with Power Regeneration 4.16 kv, 500 to 4000 HP, UL Listed Also available in 3 kv and 6kV Class Certified for ISO9001 and ISO14001 CERTI F I ED

More information

Shenzhen Sine Electric Co., Ltd.

Shenzhen Sine Electric Co., Ltd. Page 1 of 5 Favorite Contact 中文 Please enter key words 提交查 Home Products Solutions Service About us Products EM500 Open loop Inverter Your current location:home > Products Standard Inverters EM500 Open

More information

Electrohydraulic Servo Drive

Electrohydraulic Servo Drive Electrohydraulic Servo Drive Shenzhen Veichi Electric Co., Ltd. is a high-tech enterprise that is professionally engaged in the development, manufacturing and marketing of industrial automation control

More information

Clean and compact drive for energy savings. Altivar Medium-voltage variable speed drive 0.3 to 10 MW

Clean and compact drive for energy savings. Altivar Medium-voltage variable speed drive 0.3 to 10 MW Clean and compact drive for energy savings ltivar 1100 Medium-voltage variable speed drive 0.3 to 10 MW Increase your productivity, make bigger savings ltivar 1100 is the latest addition to our full range

More information

Qualification certificate

Qualification certificate 1 Company profile Zhejiang Sandi Electric Co., Ltd is an international PV enterprise which is located in the "capital of China's electrical appliances" Wenzhou. Specialized in the new energy source and

More information

High-voltage Direct Inverter Applied to Induced Draft Fan Motor at Takehara Thermal Power Station No. 3 of Electric Power Development Co., Ltd.

High-voltage Direct Inverter Applied to Induced Draft Fan Motor at Takehara Thermal Power Station No. 3 of Electric Power Development Co., Ltd. Hitachi Review Vol. 53 (2004), No. 3 121 High-voltage Direct Inverter Applied to Induced Draft Fan Motor at Takehara Thermal Power Station No. 3 of Electric Power Development Co., Ltd. Hiroaki Yamada Kiyoshi

More information

Application of PLC in automatic control system in the production of steel. FAN Zhechao, FENG Hongwei

Application of PLC in automatic control system in the production of steel. FAN Zhechao, FENG Hongwei International Conference on Manufacturing Science and Engineering (ICMSE 2015) Application of PLC in automatic control system in the production of steel FAN Zhechao, FENG Hongwei Inner Mongolia Technical

More information

Unidrive M600 High performance drive for induction and sensorless permanent magnet motors

Unidrive M600 High performance drive for induction and sensorless permanent magnet motors Unidrive M600 High performance drive for induction and sensorless permanent magnet motors 0.75 kw - 2.8 MW Heavy Duty (1.0 hp - 4,200 hp) 200 V 400 V 575 V 690 V Unidrive M600 features Easy click-in keypad

More information

Technical Explanation for Inverters

Technical Explanation for Inverters CSM_Inverter_TG_E_1_2 Introduction What Is an Inverter? An inverter controls the frequency of power supplied to an AC motor to control the rotation speed of the motor. Without an inverter, the AC motor

More information

Topology. Topology of System

Topology. Topology of System R Medium Voltage Drive Technical Data NANJING AUBO ELECTRIC CO., LTD Topology The HIVERT AUBO series MV VFD adopts AC-DC-AC mode, the electronic switch component is IGBT. It is highly reliable by means

More information

Tel: Whatsapp/Wechat: Skype:carrie.rong

Tel: Whatsapp/Wechat: Skype:carrie.rong Company profile Yueqing Sandi Electric Co., Ltd specialized in the new energy source and electrical source scientific research, development, manufacture and service had surpasses for 15 years of electrical

More information

SINAMICS SM150. 4/2 Overview. 4/2 Benefits. 4/2 Design. 4/6 Function. 4/8 Selection and ordering data. 4/8 Options

SINAMICS SM150. 4/2 Overview. 4/2 Benefits. 4/2 Design. 4/6 Function. 4/8 Selection and ordering data. 4/8 Options /2 Overview /2 Benefits /2 Design /6 Function /8 Selection and ordering data /8 Options Technical data /1 General technical data /15 Control properties /15 Ambient conditions /16 Installation conditions

More information

MGE TM Galaxy TM 7000 GFC

MGE TM Galaxy TM 7000 GFC MGE TM Galaxy TM 7000 GFC Grid Frequency Converter (GFC) for Shore Connection solution 500 kva Performance 3 Phase Power Protection with high adaptability to meet the unique requirements of Shore Connection

More information

Technical Data Sheets

Technical Data Sheets GE Consumer & Industrial Power Protection Technical Data Sheets Digital Energy Uninterruptible Power Supply SitePro 150 200 250 300 kva 400 VAC CE Series 6 Manufactured by: GE Digital Energy General Electric

More information

SOLSTART Instruction Manual

SOLSTART Instruction Manual Solstart Analog Soft Starter 8-58A, 220-600V Instruction Manual Ver. 23/03/2009 2 Table of Content SOLSTART Instruction Manual 1. TABLE OF CONTENT 1. Table of Content...2 2. Safety & Warnings...3 2.1 Safety...3

More information

Applications of Frequency Conversion Technology in Aircompressor

Applications of Frequency Conversion Technology in Aircompressor Available online at www.sciencedirect.com Procedia Engineering 15 (2011) 944 948 Advanced in Control Engineeringand Information Science Applications of Frequency Conversion Technology in Aircompressor

More information

RVS-AX Instruction Manual

RVS-AX Instruction Manual RVS-AX Analog Soft Starter 8-170A, 220-600V Instruction Manual Ver. 10/11/2009 2 Table of Content RVS-AX Instruction Manual 1. TABLE OF CONTENT 1. Table of Content...2 2. Safety & Warnings...3 2.1 Safety...3

More information

Frequency Inverter SHENZHEN WINNER S&T CO., LTD. (200V-1140V) Reg. No. 059-A

Frequency Inverter SHENZHEN WINNER S&T CO., LTD. (200V-1140V) Reg. No. 059-A R Frequency Inverter (200V-1140V) SHENZHEN WINNER S&T CO., LTD. Reg. No. 059-A SHENZHEN WINNER S&T CO., LTD. Trademark Definition 1. W, the initial of WINNER, signifies the current sine waveform. It simply

More information

Presentation Soft starters 0 Altistart 48 soft start - soft stop units

Presentation Soft starters 0 Altistart 48 soft start - soft stop units Presentation Soft starters 5 6 7 65_Ver.-EN.fm/ Presentation (continued) Soft starters Applications The Altistart 8 soft start - soft stop unit is a controller with 6 thyristors which is used for the torque-controlled

More information

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual On Line UPS LUC 1000E / LUC 2000E / LUC 3000E User Manual Save This Manual Please read this manual carefully prior to storage, installation, wiring, operation and maintenance of the UPS. This manual contains

More information

Technical Data Sheets

Technical Data Sheets GE Consumer & Industrial Power Protection Technical Data Sheets Digital Energy Uninterruptible Power Supply SitePro 400 & 500 kva 400 VAC CE Series 6 Manufactured by: GE Digital Energy General Electric

More information

MEDIUM VOLTAGE DRIVE STARTER TYPE MV-SVFD-ML1

MEDIUM VOLTAGE DRIVE STARTER TYPE MV-SVFD-ML1 EDIU VOLTAGE DRIVE STARTER TYPE V-S-L1 UP TO 20 W UP TO 12 KV UP TO 520/2500 A OCOTECH PRESENTS THE VARIABLE FREQUENCY DRIVE STARTER TYPE V-S & The V- is based on multi level voltage source inverter technology

More information

Development of the Single Phase PV Inverter SANUPS P61A

Development of the Single Phase PV Inverter SANUPS P61A New Products Introduction Development of the Single Phase PV Inverter SANUPS P61A Naohiko Shiokawa Hiroshi Yamada 1. Introduction With the global warming being recognized as a major crisis in recent years,

More information

Application of ALPHA6000 Inverter in the Cement Industry

Application of ALPHA6000 Inverter in the Cement Industry Application of ALPHA6000 Inverter in the Cement Industry I. Introduction The emergence of the frequency-conversion governor has brought a revolution to the regulation method for AC (alternating current)

More information

U n i n t e r r u p t i b l e P o w e r S y s t e m

U n i n t e r r u p t i b l e P o w e r S y s t e m SMART ON-LINE UPS User s Manual U n i n t e r r u p t i b l e P o w e r S y s t e m Smart On-Line UPS 2KVA ~ 20KVA 20KVA Exhaust hole (16)Main breaker (12)Heat exhaust hole (15)Telephone (Rj11) or network

More information

MKN-DSP SERIES - THREE PHASE

MKN-DSP SERIES - THREE PHASE Output Power Factor 0.9 MKN-DSP SERIES - THREE PHASE Double conversion True On-Line UPS 3 Phase Input - 3 Phase Output 10 KVA 15 KVA 20 KVA 30 KVA 40 KVA 50 KVA 60 KVA Model for: 208/120 V 220/127 V /

More information

J1000. Compact Inverter Series.

J1000. Compact Inverter Series. J1000 Compact Inverter Series www.yaskawa.eu.com Focus on Application Customer orientation and application focus two attributes of machine equipment YASKAWA offers with its J1000 compact inverter drive

More information

Electric Car Charging Pile

Electric Car Charging Pile www.shhkk.com SHANGHAI HUAKUN AL CO., LTD. Add:No.1300, Shuguang Road, Minhang District, Shanghai, P.R. China Tel: 0086-577-62750028 Fax: 0086-577-62753229 Website: www.shhkk.com E-mail: shhkk@shhkk.com

More information

Technical Data Sheets

Technical Data Sheets GE Consumer & Industrial Technical Data Sheets Digital Energy Uninterruptible Power Supply SG-CE Series 160 200 250 300 kva PurePulse TM 400 Vac CE Series 1 Date of issue: 15.02.2007 SGSE160-200S1UPS01

More information

SINAMICS GM150 IGCT version

SINAMICS GM150 IGCT version /2 Overview /2 Benefits /2 Design /6 Function /8 Selection and ordering data /8 Options Technical data /14 General technical data /15 Control properties /15 Ambient conditions /16 Installation conditions

More information

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES GAMATRONIC, A SolarEdge Division 47505 Seabridge Drive, Fremont, CA, 94538 USA Tel: 1-800-277-5496 SalesNA.Gama@solaredge.com www.gamatronicna.com

More information

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES GAMATRONIC, A SolarEdge Division 47505 Seabridge Drive, Fremont, CA, 94538 USA Tel: 1-800-277-5496 SalesNA.Gama@solaredge.com www.gamatronicna.com

More information

Varispeed E7. Varispeed E7. Varispeed. Varispeed E7. Varispeed E7. Varispeed E7 INVERTER SERIES

Varispeed E7. Varispeed E7. Varispeed. Varispeed E7. Varispeed E7. Varispeed E7 INVERTER SERIES INVERTER SERIES Varispeed E VARISPEED E YASKAWA INVERTER DRIVE TECHNOLOGY Contents Content Page 2 Experience & Innovation A leader in Drives technology Page 3 Specifications Experience & Innovation For

More information

Power+ CLASSIC. 20/30 kva, 3x208 Vac

Power+ CLASSIC. 20/30 kva, 3x208 Vac Power+ CLASSIC 20/30 kva, 3x208 Vac with internal batteries Power+ CLASSIC 20/30 kva, 3x208 Vac Power+ is a family of modular, parallel, redundant UPS systems from Gamatronic one of the leading companies

More information

Modular Standardized Electrical and Control Solutions for Fast Track Projects

Modular Standardized Electrical and Control Solutions for Fast Track Projects Modular Standardized Electrical and Control Solutions for Supporting fast track projects ABB is the leading supplier of electrical and control equipment for power plants. The company offers a comprehensive

More information

Vacuum Circuit Breaker VS1

Vacuum Circuit Breaker VS1 Vacuum Circuit Breaker VS1 Product features Conform to GB, IEC, DL and JB standards KEMA type test Level A certificate Ideal contact material and shape, ensuring low current carrying value and stable contact

More information

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER Technical Specifications Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER Sentinel PRO CONTENTS 1. GENERAL DESCRIPTION... 2 1.1. Main features of the UPS unit... 3 1.2. Standard Versions...

More information

Power Conversion Systems 2005/2006. Schaefer the Power to make it happen.

Power Conversion Systems 2005/2006. Schaefer the Power to make it happen. Power Conversion Systems 2005/2006 Schaefer the Power to make it happen. Company profile workforce experience customer orientation flexibility reliability Schaefer Elektronik, founded in 1969, has grown

More information

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality GE Digital Energy Power Quality Technical data sheet Digital Energy Uninterruptible Power Supply VH700-1000 - 1500 2000 UL A product by: GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino

More information

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW) Product datasheet Characteristics ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/400...440V(45kW) Complementary Assembly style Function available Supply voltage limits Main Range of product

More information

MaxPak Plus Analog DC V S Drive

MaxPak Plus Analog DC V S Drive Three-Phase 3-600 HP non-regenerative and 5-150 HP regenerative drives Designed to accommodate a wide range of industrial requirements, the DC V S Drive has been widely applied worldwide. Selected ratings

More information

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option MODEL NUMBER: SUT20K Highlights On-line double-conversion topology, VFI operation

More information

PowerFlex 6000 Medium Voltage AC Drives

PowerFlex 6000 Medium Voltage AC Drives PRELIMINARY INFORMATION PowerFlex 6000 Medium Voltage AC Drives Simple. More Reliable. Easy-to-use. User-friendly Control for Variable and Constant Torque Applications Cost-effective solutions for new

More information

Electronic Ballast EVG 2000-T

Electronic Ballast EVG 2000-T Electronic Ballast EVG 2000-T Operating Manual Table of contents 1 Description 1.1 Advantages of this ballast... 3 1.2 Functional principle... 3 1.3 Energization... 4 1.4 Visualization... 5 1.5 Indications

More information

EFFEKTA Power Supplies

EFFEKTA Power Supplies EFFEKTA GENERAL INFORMATION UPS topology ON LINE - Double Conversion Classification VFI-SS-111 in accordance with IEC 62040-3 Nominal output power (Cos Ø 0,9) - kva 10 15 20 30 40 Nominal output power

More information

.3 Section Waste Management and Disposal.

.3 Section Waste Management and Disposal. Issued 2005/06/01 Section 16261 Uninterruptible Power Systems Static Page 1 of 10 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01780 Closeout Submittals..3 Section

More information

Company Profile - 0 -

Company Profile - 0 - Company Profile - 0 - Table of Contents Overview Manufacturing Quality Management Product Introduction Test Equipment R&D Centre Service Support - 1 - Company introduction KEWO ELECTRIC TECHNOLOGY CO.,

More information

SMS PRODUCT CATALOGUE

SMS PRODUCT CATALOGUE SMS PRODUCT CATALOGUE CONTENTS 1 TAKEDO 3VF-NXP - LIFT INVERTER Page 3 2 TAKEDO 3VF-V20 - OPEN LOOP LIFT INVERTER Page 6 3 TAKEDO ENERGY - DYNAMIC BRAKING REGENERATIVE UNIT Page 7 4 HYDROVERT VVVF FOR

More information

Honeywell CORE Drive FEATURES APPLICATION SPECIFICATION DATA

Honeywell CORE Drive FEATURES APPLICATION SPECIFICATION DATA Honeywell CORE Drive SPECIFICATION DATA FEATURES APPLICATION The new Honeywell VFD CORE Drive addresses the need to save time for installation, and provides the lower total installed costs with years of

More information

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4 USER S MANUAL PowerWalker VFI 1000 / 3000VA CONTENTS 1. INTRODUCTION...... 1 2. SAFTY INSTRUCTION......... 2 3. SYSTEM DESCRIPTION......... 4 4. CABLE CONNECTION......... 7 5. OPERATION...... 8 6. TROUBLE

More information

Three Phase UPS Systems Range: 10 to 500kVA

Three Phase UPS Systems Range: 10 to 500kVA Three Phase UPS Systems Range: 10 to 500kVA Three Phase UPS Systems Hitachi Hi-Rel Power Electronics Pvt. Ltd. is in the business of Industrial UPS Systems since 1987 and has rich experience in supplying

More information

RVS-DN Digital Reduced Voltage Motor Starter

RVS-DN Digital Reduced Voltage Motor Starter RVS-DN Digital Reduced Voltage Motor Starter Specification Guide Specification Guide Contents 1.0 Introduction 2.0 Specifications 2.1 Standard Performance Features 2.2 Standard Protection Features 2.3

More information

Zhejiang Sandi Electric Co., Ltd is an international PV enterprise which is located in the "capital of China's electrical appliances" Wenzhou.

Zhejiang Sandi Electric Co., Ltd is an international PV enterprise which is located in the capital of China's electrical appliances Wenzhou. 1 Company profile Zhejiang Sandi Electric Co., Ltd is an international PV enterprise which is located in the "capital of China's electrical appliances" Wenzhou. Specialized in the new energy source and

More information

SAVER DSP SERIES. 3-10kVA USER MANUAL

SAVER DSP SERIES. 3-10kVA USER MANUAL . SAVER DSP SERIES. SINGLE PHASE IN SINGLE PHASE OUT 3-10kVA USER MANUAL UNINTERRUPTIBLE POWER SUPPLY UPS 288713578 Important Notices Thank you for choosing Inform UPS Systems. This document provides

More information

MODULAR THREE-PHASE AND SINGLE-PHASE UPS SYSTEM

MODULAR THREE-PHASE AND SINGLE-PHASE UPS SYSTEM MODULAR THREE-PHASE AND SINGLE-PHASE UPS SYSTEM PowerLine DPA 20 120 kva Full power for industrial applications PowerLine DPA 20 120 kva Full power for industrial applications 2 ABB UPS SYSTEMS POWERLINE

More information

Tension Control Inverter

Tension Control Inverter Tension Control Inverter MD330 User Manual V0.0 Contents Chapter 1 Overview...1 Chapter 2 Tension Control Principles...2 2.1 Schematic diagram for typical curling tension control...2 2.2 Tension control

More information

SecureUPS On-Line 120V AC Output, 1300VA

SecureUPS On-Line 120V AC Output, 1300VA SecureUPS On-Line 120V AC Output, 1300VA Trusted Power Protection Solution for Intelligent Transportation Systems (ITS) Challenges Intelligent transportation systems (ITS) are using innovative traffic

More information

Technical data sheets

Technical data sheets GE Consumer & Industrial Power Protection Technical data sheets Digital Energy Uninterruptible Power Supply LP 11 Series / 3 5 6 8 10 kva A product by: GE Consumer & Industrial SA General Electric Company

More information

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work Technical Data Sheet Uninterruptible Power Supply SGSE_010-040_S1_UPS_GE_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850 51 51 F +41 (0)91

More information

OFF-GRID Hybrid (BI-DIRECTIONAL) SOLAR INVERTER SOLAR INVERTER SOLAR UPS

OFF-GRID Hybrid (BI-DIRECTIONAL) SOLAR INVERTER SOLAR INVERTER SOLAR UPS OFF-GRID Hybrid (BI-DIRECTIONAL) SOLAR INVERTER SOLAR INVERTER SOLAR UPS ITS Power & Infrastructure Pvt. Ltd. is a leading designs, manufacturer & supplier of power product. ITS Power Company is in Bavdhan,

More information

SD700FR. Regenerative Active Front End VARIABLE SPEED DRIVES POWER ELECTRONICS / SD700 SERIES 4 QUADRANT. icool

SD700FR. Regenerative Active Front End VARIABLE SPEED DRIVES POWER ELECTRONICS / SD700 SERIES 4 QUADRANT. icool FR VARIABLE SPEED DRIVES Regenerative Active Front End icool 4 QUADRANT POWER ELECTRONICS / SD700 SERIES FR SD700FR SERIES goes one step ahead keeping the family unique characteristics. Based on the latest

More information

Yueqing Sandi Electric Co., Ltd is an international PV enterprise which is located in the "capital

Yueqing Sandi Electric Co., Ltd is an international PV enterprise which is located in the capital Tel: +86-57762776918 E-mail: carrie@sandi.cc Whatsapp/Wechat: 13175696608 Skype:carrie.rong Company profile Yueqing Sandi Electric Co., Ltd is an international PV enterprise which is located in the "capital

More information

A softstarter beyond the ordinary

A softstarter beyond the ordinary A softstarter beyond the ordinary Emotron MSF 2.0 Softstarter More than just Starting an electrical motor involves a number of challenges, such as high start currents and mechanical stress on equipment.

More information

Solar Inverter Manual

Solar Inverter Manual Solar Inverter Manual Introduction SMPS series solar inverter power charging efficiency increased by 30%~60% than traditional controller charging. This inverter has automatic identification, three-stage

More information

SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option MODEL NUMBER: SVT20KX Highlights On-line double-conversion topology, VFI operation

More information

Technical Data Sheets

Technical Data Sheets GE Digital Energy Power Quality Technical Data Sheets Digital Energy Uninterruptible Power Supply SG-CE Series 60 80 100 120 kva PurePulse 400 Vac CE Series 1 SG-CE Series 100-120 kva PurePulse SG-CE Series

More information

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option MODEL NUMBER: SUT30K Highlights On-line double-conversion topology, VFI operation

More information

10 20KVA 3Ph/1Ph KVA 3Ph / 3Ph

10 20KVA 3Ph/1Ph KVA 3Ph / 3Ph VEGA INDUSTRIAL UNINTERRUPTIBLE POWER SUPPLY 10 20KVA 3Ph/1Ph 10 120KVA 3Ph / 3Ph - 6 pulse SCR rectifier - IGBT inverter - Power output transformer - Low and stable ripple on battery for the highest battery

More information

BR Second Position Voltages. AA Fourth Position

BR Second Position Voltages. AA Fourth Position 1336S First Position Bulletin Number BR Second Position Voltage Letter AQ BR CW A B BP BX C Q R RX W Voltages 200-240V AC or 3V DC 380-480VAC or 513-620V DC 500-600V AC or 775V DC or 200-240V AC 380-480V

More information

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out) TECHNICAL DATA SHEET INFINITY 3300 10 15 20 kva 3Ph(in) 3Ph(out) GENERAL INFORMATION POWER - kva 10 15 20 UPS typology ON LINE Double conversion ACTIVE stand by-operation (Optional) Nominal output power

More information

Product brochure. Medium voltage AC drive ACS2000, kw, kv

Product brochure. Medium voltage AC drive ACS2000, kw, kv Product brochure Medium voltage AC drive ACS2000, 250 2600 kw, 4.0 6.9 kv 2 ACS2000 brochure ABB ACS2000 flexible and reliable motor control The ACS2000 medium voltage AC drive provides reliable motor

More information

HIGH PERFORMANCE VECTOR CONTROL DRIVE

HIGH PERFORMANCE VECTOR CONTROL DRIVE JI350 SERIES IP 54 Drive for PMSM and IM Accuracy speed and torque control for motor VF control and vector control 180% rated starting torque Plug n play control box with emergency stop HIGH PERFORMANCE

More information

Product brochure. Medium voltage AC drive ACS 2000, kva, kv

Product brochure. Medium voltage AC drive ACS 2000, kva, kv Product brochure Medium voltage AC drive ACS 2000, 400 1000 kva, 6.0 6.9 kv 2 ACS 2000 brochure ABB ACS 2000 simple and reliable motor control The ACS 2000 is the latest member of the ABB medium voltage

More information

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work Technical Data Sheet Uninterruptible Power Supply SGSE_400-500_S3_UPS_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850 51 51 F +41 (0)91

More information

kVA. Liebert NX. Enterprise-Scale UPS Protection For Medium And Large Data Centers

kVA. Liebert NX. Enterprise-Scale UPS Protection For Medium And Large Data Centers 250-800kVA Liebert NX Enterprise-Scale UPS Protection For Medium And Large Data Centers Efficiency. Availability. Capacity. Control. Facility managers continue to face the increasing cost of energy consumption

More information

USER MANUAL MPS 1-5KW SERIES

USER MANUAL MPS 1-5KW SERIES USER MANUAL MPS 1-5KW SERIES Low Series Frequency Solar and Wind Power Charging Inverter CONTENTS 1 WWW.NEXTGENNRG.COM 1. Introduction... 3 2. Profile Structure 4 2.1. Working Principle 4 2.2.Product Features..5

More information

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC Manufacturer s declaration in accordance with 8- Frame Model catalogue reference 93PS-XX(20)-YY- 93PS-XX(40)-YY- Number of power modules (UPM) 1 1 or 2 Number of internal batteries 0 to 2 x 32 blocks 0

More information

Illuminator Series CM. GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION. 500W, 1000W, 1500W and 2000W Single-Phase Emergency Power System

Illuminator Series CM. GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION. 500W, 1000W, 1500W and 2000W Single-Phase Emergency Power System Illuminator Series CM GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION 500W, 1000W, 1500W and 2000W Single-Phase Emergency Power System This description contains all the necessary functional and technical

More information

Sola/Hevi-Duty S3K Series Mini-Tower UPS

Sola/Hevi-Duty S3K Series Mini-Tower UPS Sola/Hevi-Duty S3K Series Mini-Tower UPS GUIDE SPECIFICATIONS 700VA to 1600VA 120V models Single - Phase Uninterruptible Power Supply Systems 1.1 SUMMARY 1.0 GENERAL This specification defines the electrical

More information

EAST GROUP COMPANY PROFILE. Energy storage solutions. About us. Grid-connected PV systems. Our Products. Our Team. UPS solutions

EAST GROUP COMPANY PROFILE. Energy storage solutions. About us. Grid-connected PV systems. Our Products. Our Team. UPS solutions EAST GROUP Energy storage solutions In this catalogue, you will find all components and services related to energy storage solutions, which include off-grid and hybrid solar systems, GF series single phase

More information

PSW102 type CT powered protection unit

PSW102 type CT powered protection unit PSW102 type CT powered protection unit Summary PSW102CT self-powered protection device is a 10Kv feeder protection device which has the function of over current, fast breaking protection and grounding

More information

Qingdao Zener Electric Co., Ltd

Qingdao Zener Electric Co., Ltd Traction inverter, Power Supply, Emergency ventilation inverter for Light rail train Qingdao Zener Electric Co., Ltd Part 1 Power Supply for the Overhead Traction Line Introduction Conventional power supply

More information

Sunny Tripower. Can do everything that we can

Sunny Tripower. Can do everything that we can Sunny Tripower Can do everything that we can New Features Optiflex Flexible Plant Design Optiprotect Electronic String Fuse Optiprotect Integrable Type II Overvoltage Protection Optiprotect Intelligent

More information

CATALOG. ABB micro drives ACS55, 0.18 to 2.2 kw

CATALOG. ABB micro drives ACS55, 0.18 to 2.2 kw CATALOG ABB micro drives ACS55, 0.18 to 2.2 kw 2 ABB MICRO DRIVES, ACS55, 0.18 TO 2.2 KW/0.25 TO 3 HP Ease of integration. ACS55 drives. 3 Table of contents 004 ABB micro drives, ACS55 005 Easily integrated

More information

Liebert NX TM. 250kVA kVA Transformer-free. High Efficiency, Scalable On-line UPS

Liebert NX TM. 250kVA kVA Transformer-free. High Efficiency, Scalable On-line UPS Transformer-free. High Efficiency, Scalable On-line UPS LIEBERT Liebert NX NX TM TM UPS 250-250kVA 1000-1000kVA Facility managers continue to face the increasing outlay of energy consumption and the call

More information

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply APC Smart-UPS GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply PART 1 - GENERAL 1.1 SUMMARY A. This specification describes the operation and functionality of a continuous

More information

SYSDrive Frequency Inverter

SYSDrive Frequency Inverter SYSDrive Frequency Inverter T V/f control T PID control T Standard LED, optional LCD operator T Fieldbus options: DeviceNet T 7 configurable digital inputs T 3 configurable digital outputs T Low audible

More information

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work Technical Data Sheet Uninterruptible Power Supply TLES_040-120_S1_UPS_GE_Floor_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850 51 51 F +41

More information

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out) TECHNICAL DATA SHEET B8033FXS 10 15 20 kva 3Ph(In) 3Ph(Out) GENERAL INFORMATION UPS Type ON LINE Double Conversion Nominal output power (Cosϕ 0.9) kva 10 15 20 Nominal output power (Cosϕ 1.0) kw 9 13.5

More information

Application. Battery. Public Grid GS HYBRID INVERTER

Application. Battery. Public Grid GS HYBRID INVERTER GS HYBRID SOLAR INVERTER Feed from Solar and Power, Grid backup, Build-in Transfer Switch / Solar Charger/ AC Charger, 500W~3kW, Pure Sine Wave Output GSH-15XX and GSH-30XX are the ideal solutions for

More information

POWER kva

POWER kva TECHNICAL DATA SHEET B9000 FXS 60-80-100-125-160kVA +44 (0)20 8868 3732 GENERAL INFORMATION UPS Type ON LINE Double Conversion Nominal output power (Cos φ 0,8) kva 60 80 100 125 160 Nominal output power

More information

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work Technical Data Sheet Uninterruptible Power Supply TM SG Series 100 &120 PurePulse TM SG Series 60 & 80 PurePulse SGSE_060-120_S1_UPS_GE_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino

More information