1 Technical Information CPM280 ph/orp measurement Battery-driven pocket meter for ph and ORP measurement Application CPM280 is a pocket meter for measuring ph value and ORP. It is suitable for the following fields of application: Wastewater treatment plants Drinking and surface water Laboratory and field measurement Your benefits Comfortable operation: Clear multi-function display with user guidance Precise measurement: Automatic temperature compensation via the ph combination electrode with built-in temperature sensor (NTC 30) Flexible calibration: Conventional calibration with two buffer solutions Fully automatic two-point or three-point calibration with pre-defined buffer solutions according to DIN Fully automatic two-point or three-point calibration with Endress+Hauser quality buffer solutions Safe and cost-effective operation: Long service life with four commonly used 1.5 V batteries: approx h Automatic power-down Dust and water-proof housing (IP 66) TI346C/07/en/

2 Function and system design Measuring principle Measuring system! Note! ph measurement The ph value is used as a unit of measurement for the acidity or alkalinity of a liquid medium. The membrane glass of the electrode supplies an electrochemical potential which is dependent upon the ph value of the medium. This potential is generated by the selective penetration of H + ions through the outer layer of the membrane. An electrochemical boundary layer with an electric potential forms at this point. An integrated Ag/AgCl reference system serves as reference electrode. The transmitter converts the measured voltage into the corresponding ph value using the Nernst equation. Redox measurement The redox potential is a unit of measurement for the state of equilibria between oxidising and reducing components of a medium. Redox potential is measured similarly to the ph value. A platinum or gold electrode is used instead of ph-sensitive membrane glass. Analog to the ph measurement, an integrated Ag/AgCl reference system is used as a reference electrode. A complete measuring system comprises: CPM280 pocket meter Norylab CPS51 ph combination electrode with built-in temperature sensor NTC 30, fixed cable and water-proof DIN plug Plastic bowl for sampling You can use the supplied stand as a sensor holder. 1 2 Measuring system 1 Pocket meter 2 Sensor cable 3 Sensor 4 Plastic bowl 4 3 a Endress+Hauser

3 Input Measured variable Measuring range ph value or ORP [mv] ph value: -2 to 16 ORP: to mv Temperature: -5 to 100 C (20 to 212 F) Power supply Electrical connection via fixed cable and DIN plug Ref Electrical connection 1 ph sensor connection 2 Temperature sensor connection 3 Reference electrode connection a Supply voltage Battery power Service life 4 x 1.5 V alkaline-manganese batteries, type AA approx h Performance characteristics Reference operating conditions Reference temperature: Reference pressure: 25 C (77 F) 1013 hpa (15 psi) Maximum measured error Temperature compensation ph value: ORP: Temperature: -5 to 80 C (20 to 180 F) 0.01 ph ± 1 digit 0.3 mv ± 1 digit 0.1 K ± 1 digit Endress+Hauser 3

4 Environment Storage temperature 5 to +65 C (20 to 150 F) Ingress protection IP 66 Climate class climate class 2 Electromagnetic compatibility Interference emission acc. to DIN EN / Process Process temperature -5 to 80 C (20 to 180 F) Design, dimensions pocket meter Mechanical construction 80 (3.15) 38 (1.5) 80 (3.15) 172 (6.77) 38 (1.5) 35 (1.38) mm (inch) a Endress+Hauser

5 Design, dimensions case and sensor mm (inch) 355 (14.0) 115 (4.53) 305 (12.0) 120 (4.72) mm (inch) 12 (0.47) Case dimensions a Sensor dimensions a Weight Pocket meter Sensor Case, total weight 0.4 kg (0.9 lbs) 0.1 kg (0.2 lbs) 2.2 kg (4.9 lbs) Materials Pocket meter Housing: Keypad: Sensor Membrane glass: polypropylen (PP) silicone UNITEC Human interface Display elements Measured value Status display Sensor symbol Temperature Displayed functions 5 4 LC display a Displayed functions LoBat TP AutoCal DIN AutoCal TEC CalError ARng AR Low battery Symbol of the temperature display Automatic calibration function, buffer solutions acc. to DIN Automatic calibration function, Endress+Hauser quality buffer ph 4, ph 7 Calibration error Autorange function on Autorange function off Endress+Hauser 5

6 Operating elements M CAL I AR M I CAL AR RUN/ ENTER Operation mode On/off Calibrate Autoread on/off (Hold function) Run/Enter RUN/ENTER Keypad a Ordering information Order number Scope of delivery ph/orp pocket meter CPM280 order no The measuring set comprises: 1 CPM280 pocket meter 1 Norylab CPS51 ph combination electrode with built-in NTC 30 temperature sensor, 1.5 m (4.9 ft) fixed cable and water-proof DIN plug 2 plastic bottles with buffer solutions ph 4 and ph 7, 50 ml (1.7 fl.oz) each 1 plastic bottle with electrolyte solution 3 mol/l KCl, 50 ml (1.7 fl.oz) 1 plastic bowl 50 ml (1.7 fl.oz) 1 stand used as electrode holder 4 alkali-manganese batteries 1.5 V 1 solid plastic case made from PP with integrated measuring point and separate pocket for sensor and accessories 1 Operating Instructions BA346C/07/b4 6 Endress+Hauser

7 Accessories and spare parts Sensor Calibration solutions Orbisint CPS51/CPS52 ph resp. ORP sensor with plastic shaft for pocket meter with built-in temperature sensor Order nos: CPS51-7EK2FDA (ph sensor) CPS52-0PK2FDA (ORP sensor) Technical buffer solutions for ORP electrodes +220 mv, ph 7.0, 100 ml (3.4 fl.oz.); order no. CPY mv, ph 0.1, 100 ml (3.4 fl.oz.); order no. CPY3-1 High-quality buffer solutions of Endress+Hauser The secondary buffer solutions have been referenced to primary reference material of the PTB (German Federal Physico-technical Institute) and to standard reference material of NIST (National Institute of Standards and Technology) according to DIN by a DKD (German Calibration Service) accredited laboratory. ph value A ph 2.00 (accuracy ± 0.02 ph) C ph 4.00 (accuracy ± 0.02 ph) E ph 7.00 (accuracy ± 0.02 ph) G ph 9.00 (accuracy ± 0.02 ph) I ph 9.20 (accuracy ± 0.02 ph) K ph (accuracy ± 0.05 ph) M ph (accuracy ± 0.05 ph) Quantity x 18 ml (0.68 fl.oz) only buffer solutions ph 4.00 and ml (8.45 fl.oz) ml (0.26 US gal) ml (1.32 US gal) canister for Topcal S Certificates A Buffer analysis certificate Version 1 Standard CPY20- complete order code Endress+Hauser 7

8 Instruments International Endress+Hauser Instruments International AG Kaegenstrasse Reinach Switzerland Tel Fax info@ii.endress.com TI346C/07/en/ Printed in Germany / FM+SGML 6.0 / DT

Conductivity Measurement CLM 280

Conductivity Measurement CLM 280 Technical Information TI 347C/07/en/07.03 51511754 Conductivity Measurement CLM 280 Battery-driven pocket meter for conductivity and resistance measurement Application CLM 280 is a compact pocket meter

More information

Orbipore CPS91 and CPS91D

Orbipore CPS91 and CPS91D Technical Information Orbipore CPS91 and CPS91D ph electrodes, analog or with digital Memosens technology With open aperture for heavily soiled media, optional built-in temperature sensor Application Chemical

More information

Orbisint CPS11 and CPS11D

Orbisint CPS11 and CPS11D Technical Information Orbisint CPS11 and CPS11D ph electrodes, analog or with digital Memosens technology For standard applications in process and environment technology, with dirt-repellent PTFE diaphragm,

More information

Orbisint CPS12/CPS12D/CPS13

Orbisint CPS12/CPS12D/CPS13 Technical Information Orbisint CPS12/CPS12D/CPS13 ORP electrodes, analog and digital with Memosens technology and reference electrode Each with dirt-repellent PTFE diaphragm for standard applications in

More information

Technical Information Ceraliquid CPS41D and CPS41

Technical Information Ceraliquid CPS41D and CPS41 TI00079C/07/EN/13.15 71277561 Products Solutions Services Technical Information Ceraliquid CPS41D and CPS41 ph electrodes, digital with Memosens technology, and analog For process engineering with ceramic

More information

Orbisint CPS11 and CPS11D

Orbisint CPS11 and CPS11D Technical Information Orbisint CPS11 and CPS11D ph electrodes, analogue and digital with Memosens technology For standard applications in process and environment technology, with dirt-repellent PTFE diaphragm,

More information

Ceraliquid CPS42/CPS42D/CPS43

Ceraliquid CPS42/CPS42D/CPS43 Technical Information Ceraliquid CPS/CPSD/CPS ORP electrodes, analog and digital with Memosens technology and reference electrode Each with ceramic diaphragm and liquid KCl electrolyte Application Media

More information

Ceraliquid CPS41 and CPS41D

Ceraliquid CPS41 and CPS41D Technical Information Ceraliquid CPS and CPSD ph electrodes, analog and digital with Memosens technology With ceramic diaphragm and liquid KCl electrolyte, optional built-in temperature sensor Application

More information

Flowfit CPA250. Technical Information. Flow assembly for ph and ORP sensors

Flowfit CPA250. Technical Information. Flow assembly for ph and ORP sensors Technical Information Flowfit CPA250 Flow assembly for ph and ORP sensors Application The CPA250 assembly is totally made of corrosion resistant plastic. It is designed for pipeline installation of Pg

More information

Cleanfit W CPA450. Technical Information. Retractable assembly for 12 mm sensors for DO/pH/ORP measurement

Cleanfit W CPA450. Technical Information. Retractable assembly for 12 mm sensors for DO/pH/ORP measurement Technical Information Cleanfit W CPA450 Retractable assembly for 12 mm sensors for DO/pH/ORP measurement Application Pulp and paper industry Chemical industry Measurement in fibrous or coating media Tanks

More information

Technical Information

Technical Information Technical Information Ceragel CPS71 and CPS71D ph electrodes, analog and digital with Memosens technology For process technology, hygienic and sterile applications, with double junction reference system

More information

Cleanfit P CPA472D. Technical Information. Retractable process assembly for ph, ORP and other industry sensors Heavy-duty version

Cleanfit P CPA472D. Technical Information. Retractable process assembly for ph, ORP and other industry sensors Heavy-duty version Technical Information Cleanfit P CPA472D Retractable process assembly for ph, ORP and other industry sensors Heavy-duty version Application Chemical industry Power plants Plant design Tanks and process

More information

Cleanfit CPA471. Technical Information. Compact retractable assembly for installation of ph, ORP electrodes in tanks or pipelines

Cleanfit CPA471. Technical Information. Compact retractable assembly for installation of ph, ORP electrodes in tanks or pipelines Technical Information Cleanfit CPA471 Compact retractable assembly for installation of ph, ORP electrodes in tanks or pipelines Application Chemical industry Wastewater treatment Plant design Tanks and

More information

Cleanfit H CPA475. Technical Information. Retractable assembly for ph, ORP measurement under sterile conditions

Cleanfit H CPA475. Technical Information. Retractable assembly for ph, ORP measurement under sterile conditions Technical Information Cleanfit H CPA475 Retractable assembly for ph, ORP measurement under sterile conditions Application Food industry Beverage industry Pharmaceutical industry Drinking water The retractable

More information

Technical Information Cleanfit CPA472D

Technical Information Cleanfit CPA472D TI00403C/07/EN/13.13 71227170 Products Solutions Services Technical Information Cleanfit CPA472D Retractable process assembly for ph and ORP sensors Heavy duty version Application Chemical industry Biodiesel

More information

Signet DryLoc ph/orp Electrodes

Signet DryLoc ph/orp Electrodes Signet 2774-2777 DryLoc ph/orp Electrodes Features Patented DryLoc connector with gold plated contacts* Special design allows for installation at any angle, even inverted or horizontal Quick temperature

More information

Signet ph/orp Electrodes

Signet ph/orp Electrodes Signet 2724-2726 ph/orp Electrodes Compatible with ALL Signet ph/orp Instruments Features Flat Glass Protected Bulb Patented reference design for exceptional performance * Mounts in Signet standard fittings

More information

Signet DryLoc ph/orp Electrodes

Signet DryLoc ph/orp Electrodes Signet 2774-2777 DryLoc ph/orp Electrodes Features Patented DryLoc connector with gold plated contacts* Special design allows for installation at any angle, even inverted or horizontal Quick temperature

More information

Signet ph/orp Electrodes

Signet ph/orp Electrodes Signet 2724-2726 ph/orp Electrodes Compatible with ALL Signet ph/orp Instruments Features Patented reference design for exceptional performance * Mounts in Signet standard fittings from DN15 to DN100 (½

More information

Personal ph, ph/orp, Conductivity Meters

Personal ph, ph/orp, Conductivity Meters Personal ph, ph/orp, Meters // Personal ph, ph/orp, Meters Bulletin 12B03D01-01E www.yokogawa.com/an/ Compact and lightweight 220g IP67 Waterproof CE,RCM,KC Various Convenient Data memory Alarm Clock Date/time

More information

GHMsilverline Handheld Instruments

GHMsilverline Handheld Instruments GHM Messtechnik GmbH Hans-Sachs-Str. 26 93128 Regenstauf Germany Fon +49 (0) 9402-9383 - 0 Fax - 33 www.ghm-messtechnik.de info@ghm-messtechnik.de Handheld Instruments Characteristics System Measurands

More information

PH60 Series Premium ph Testers

PH60 Series Premium ph Testers PH60 Series Premium ph Testers Instruction Manual PH60 ph Tester PH60S Spear ph Tester PH60F Flat ph Tester APERA INSTRUMENTS (Europe) GmbH www.aperainst.de v5.6 Thank you for purchasing the Apera Instruments

More information

Signet ph/orp Electrodes

Signet ph/orp Electrodes Signet 2734-2736 ph/orp Electrodes Compatible with Signet 8900/9900 Instruments Features Patented reference design for exceptional performance * Mounts in Signet standard fittings from DN15 to DN100 (½

More information

Flowfit CYA251. Technical Information. Flow assembly for nitrate/sac, turbidity and oxygen sensors

Flowfit CYA251. Technical Information. Flow assembly for nitrate/sac, turbidity and oxygen sensors Technical Information Flowfit CYA251 Flow assembly for nitrate/sac, turbidity and oxygen sensors Application The CYA251 flow assembly is designed for the installation of sensors with a diameter of 40 mm

More information

Operating Instructions. Flowfit W CPA250. Flow assembly for ph/orp sensors. BA041C/07/en/

Operating Instructions. Flowfit W CPA250. Flow assembly for ph/orp sensors. BA041C/07/en/ Operating Instructions Flowfit W CPA250 Flow assembly for ph/orp sensors BA041C/07/en/02.07 51517581 Brief overview Fig. 1: CPA250 with Sensor 1 Reference bore 1) for electrolyte supply from reservoir

More information

SPT- I / U PRESSURE TRANSMITTER for general applications

SPT- I / U PRESSURE TRANSMITTER for general applications Fields of application Design Examples Hydraulics Air conditioning and heating Testing technology Industrial robots Process controlling Water technology Pneumatics Description The pressure transmitters

More information

AP300 Series Combination ph/redox (ORP) Sensors. Measurement made easy. A reliable economic solution for a wide range of applications

AP300 Series Combination ph/redox (ORP) Sensors. Measurement made easy. A reliable economic solution for a wide range of applications Data sheet DS/AP00 EN Rev. F AP00 Series Measurement made easy A reliable economic solution for a wide range of applications Long life large PTFE junction provides resistance to fouling double junction

More information

Rod probe 11375Z. Technical Information. Conductive level limit detection Partially insulated rod probe for use in conductive liquids

Rod probe 11375Z. Technical Information. Conductive level limit detection Partially insulated rod probe for use in conductive liquids Technical Information Rod probe 11375Z Conductive level limit detection Partially insulated rod probe for use in conductive liquids Application Conductive level limit detection in process or storage tanks

More information

* * Rev. 9 01/18 Product Manual

* * Rev. 9 01/18 Product Manual English Signet 2760 DryLoc ph/orp Preamplifier *3-2760.090* 3-2760.090 Rev. 9 01/18 Product Manual Description The Signet 2760 ph/orp Preamplifiers with DryLoc connectors are part of Signet's growing line

More information

JUMO tecline HD ph and JUMO tecline HD Rd

JUMO tecline HD ph and JUMO tecline HD Rd Page 1/7 JUMO tecline HD ph and JUMO tecline HD Rd ph and redox combination electrodes in glass shaft version Series 201021 ph electrodes Series 201026 redox electrodes Brief description JUMO tecline HD

More information

Signet 2760 DryLoc ph/orp Preamplifier

Signet 2760 DryLoc ph/orp Preamplifier Signet 2760 DryLoc ph/orp Preamplifier *3-2760.090* 3-2760.090 Rev. H 05/11 English English SAFETY INSTRUCTIONS 1. Depressurize and vent system prior to installation or removal. 2. Confi rm chemical compatibility

More information

Signet 3719 ph/orp Wet-Tap

Signet 3719 ph/orp Wet-Tap Signet 3719 ph/orp Wet-Tap *3-3719.090* 3-3719.090 Rev H 09/07 English Do not exceed maximum temperature/pressure specifications. Wear safety goggles or face shield during installation/service. Do not

More information

General Purpose ph/orp Sensors

General Purpose ph/orp Sensors General Purpose ph/orp Sensors Product Data Sheet LIQ_PDS_3900 September 2013 General Purpose ph/orp Sensors SMART preamplifier-stores calibration and other data. Extended sensor life provided by double

More information

Soliswitch FTE30. Technical Information

Soliswitch FTE30. Technical Information Technical Information Soliswitch FTE30 Level limit switch Economical paddle limit switch with type-examination certificate to ATEX dust Ex-approval zone 20 Application The universal paddle level limit

More information

Instruction Manual Portamess 911 Cond

Instruction Manual Portamess 911 Cond Instruction Manual Portamess 911 Cond ProMinent Dosiertechnik GmbH D-69123 Heidelberg Germany ProMinent Dosiertechnik GmbH Im Schuhmachergewann 5 11 D-69123 Heidelberg Postfach 10 17 60 D-69007 Heidelberg

More information

Signet 3719 ph/orp Wet-Tap Assembly

Signet 3719 ph/orp Wet-Tap Assembly Signet 3719 ph/p Wet-Tap Assembly Features Electrode removal without process shutdown Space saving 45 mm (1.75 in.) short-stroke design Sealed pneumatic dampening for smooth and safe operation SafeLoc

More information

Indumax P CLS50. Technical Information. Highly resistant, inductive conductivity sensor for standard, hazardous and high-temperature applications

Indumax P CLS50. Technical Information. Highly resistant, inductive conductivity sensor for standard, hazardous and high-temperature applications Technical Information Indumax P CLS50 Highly resistant, inductive conductivity sensor for standard, hazardous and high-temperature applications Application CLS50 conductivity sensors are especially suitable

More information

HI 8510-HI 8512 HI 8710-HI 8711 HI 8720-HI HI HI

HI 8510-HI 8512 HI 8710-HI 8711 HI 8720-HI HI HI Instruction Manual HI 8510-HI 8512 HI 8710-HI 8711 HI 8720-HI 931500 HI931501-HI 932500 Panel - Mounted ORP - ph Indicators and Controllers ORP HI 8720E mv DOSAGE SLOPE OXID. REDUC. MEA SURE AL COARSE

More information

ortable ph, Conductivity & DO2 Meters

ortable ph, Conductivity & DO2 Meters ortable ph, Conductivity & DO2 Meters Enterprise Range Large, back lit LCD Ergonomic design These ergonomically designed products feature a backlit liquid crystal display, a reading hold function and 500

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET. AP200 Rugged ph/redox (ORP) sensor systems with rapid temperature response for critical processes

ABB MEASUREMENT & ANALYTICS DATA SHEET. AP200 Rugged ph/redox (ORP) sensor systems with rapid temperature response for critical processes ABB MEASUREMENT & ANALYTICS DATA SHEET AP200 Rugged ph/redox (ORP) sensor systems with rapid temperature response for critical processes 2 AP200 RUGG ED P H / REDOX ( ORP ) SE NSOR SYSTE MS DS/AP200-E

More information

Bante220 Portable ph Meter Instruction Manual

Bante220 Portable ph Meter Instruction Manual Bante220 Portable ph Meter Instruction Manual BANTE INSTRUMENTS CO., LTD Bante220 Portable ph Meter 1 Introduction Thank you for selecting the Bante220 portable ph meter. This manual provides a step-by-step

More information

ph-kompaktelektrodensystem sensopac CPA 320

ph-kompaktelektrodensystem sensopac CPA 320 Technische Information TI 0C/0/de ph-kompaktelektrodensystem sensopac CPA 0 One of the two reference systems is specially protected so that only the second monitoring reference system is affected by penetration

More information

Technical Information Cleanfit CPA451

Technical Information Cleanfit CPA451 TI00343C/07/EN/13.14 71266614 Products Solutions Services Technical Information Manually operated retractable assembly for water, wastewater and process media Application Industrial and communal waste

More information

SIGNET 2750 ph/orp Sensor ENGLISH

SIGNET 2750 ph/orp Sensor ENGLISH ENGLISH 3-2750.090 B-8/01 English SAFETY INSTRUCTIONS FOR IN-LINE ELECTRODE INSTALLATION 1. Do not remove from pressurized lines. 2. Do not exceed maximum temperature/pressure specifications. 3. Wear safety

More information

RTD Temperature Sensor omnigrad T -TR 470

RTD Temperature Sensor omnigrad T -TR 470 Technical Information TI 272T/02/en 60021665 RTD Temperature Sensor omnigrad T -TR 470 RTD sensor with Pt 100, class A Process connection threaded or with compression fitting Application The Omnigrad T

More information

Portable pressure calibrator, Wally Box III Model CPH7600

Portable pressure calibrator, Wally Box III Model CPH7600 Calibration technology Portable pressure calibrator, Wally Box III Model CPH7600 WIKA data sheet CT 17.01 Applications Calibration service companies and service industry Measurement and control laboratories

More information

Technical Information Omnigrad TST90, TET90

Technical Information Omnigrad TST90, TET90 TI01109T/09/EN/02.13 71214205 Products Solutions Services Technical Information Resistance thermometer and insert for thermal energy measurement High-precision measurement of temperature differences with

More information

Technical Information Cleanfit CPA871

Technical Information Cleanfit CPA871 TI01191C/07/EN/03.16 71323648 Products Solutions Services Technical Information Cleanfit CPA871 Flexible retractable process assembly for water, wastewater, chemical industry and heavy industry Application

More information

Rugged ph/redox (ORP) Sensor Systems with Rapid Temperature Response for Critical Processes

Rugged ph/redox (ORP) Sensor Systems with Rapid Temperature Response for Critical Processes Data Sheet SS/AP200 Issue 7 Rugged ph/redox (ORP) Sensor Systems with Rapid Temperature Response for Critical Processes AP200 Series! Safe operation and high process resistance PPS Ryton body operates

More information

General Purpose ph/orp Sensors

General Purpose ph/orp Sensors Product Data Sheet PDS 71-3900/rev. B December 2010 Models 3900 and 3900VP General Purpose ph/orp Sensors EXTENDED SENSOR LIFE provided by double junction reference. ENHANCED PERFORMANCE AND INCREASED

More information

Analysis ph / ORP. Characteristics System. Applications Food industry Chemical and Pharmaceutical industry Water and Sewage treatment

Analysis ph / ORP. Characteristics System. Applications Food industry Chemical and Pharmaceutical industry Water and Sewage treatment GHM GROUP CORPORATE GHM Messtechnik GmbH Schloßstr. 6 88453 Erolzheim GERMANY Phone +49 7354 937233-76 Fax +49 7354 937233-88 System Process connection Pressure range Media temperature Transmitter, digital

More information

DL 01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

DL 01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05 DL 0 Battery Powered for Leak Testing Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless

More information

Digital ph transmitter

Digital ph transmitter Digital ph transmitter Compact, remote versions for DN 15 to 200 Fully programmable ph transmitter functions for all kinds of ph-measurement tasks Large range of process connections with various fittings

More information

SensoLyt 700 SensoLyt 700 SW

SensoLyt 700 SensoLyt 700 SW Operating manual SensoLyt 700 SensoLyt 700 SW SensoLyt 700 SensoLyt 700 SW ph/orp armature with impedance converter and temperature sensor ba15307e04 12/2005 SensoLyt 700 (SW) Accuracy when going to press

More information

Soliswitch FTE20. Technical Information. Point level switch for granular solids

Soliswitch FTE20. Technical Information. Point level switch for granular solids Technical Information Point level switch for granular solids Applications The is a paddle switch for granular solids. Its robust and compact design makes the point level switch an ideal sensor for detecting

More information

Encapsulated Differential ph and ORP Sensors (available in LCP, foreground, or Ryton body materials)

Encapsulated Differential ph and ORP Sensors (available in LCP, foreground, or Ryton body materials) Technology For Solutions Data Sheet LRE/102 Supersedes LRE/400 Encapsulated Differential ph and ORP Sensors (available in LCP, foreground, or Ryton body materials) Common Features Differential Electrode

More information

Table of Contents 1. OVERVIEW OPERATION FUNCTION SPECIFICATIONS INSTRUMENT LAYOUT INSTALLATION...

Table of Contents 1. OVERVIEW OPERATION FUNCTION SPECIFICATIONS INSTRUMENT LAYOUT INSTALLATION... Table of Contents 1. OVERVIEW... 2 2. OPERATION FUNCTION... 2 3. SPECIFICATIONS... 3 4. INSTRUM LAYOUT... 4 4.1 OPERATION KEY...4 4.2 INDICATORS...4 5. INSTALLATION... 5 5.1. ENVIRONM CONDITIONS...5 5.2

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET series ph and Redox (ORP) industrial dip electrode systems

ABB MEASUREMENT & ANALYTICS DATA SHEET series ph and Redox (ORP) industrial dip electrode systems ABB MEASUREMENT & ANALYTICS DATA SHEET 2867 series ph and Redox (ORP) industrial dip electrode systems 2 28 67 SE RIE S P H AN D R EDOX ( ORP) INDU STRIAL DIP E LE C TRODE SYSTE MS DS/28 67-E N RE V. F

More information

Conductivity Measuring Cells ConduMax W CLS 19

Conductivity Measuring Cells ConduMax W CLS 19 Technical Information TI 110C/24/ae Conductivity Measuring Cells ConduMax W CLS 19 Two-electrode measuring sensors with cell constant k = 0.01/cm or k = 0.1/cm Area of application Measurement in pure and

More information

Analysis ph / ORP. Applications. Characteristics. Food industry Chemical and Pharmaceutical industry Water and Sewage treatment

Analysis ph / ORP. Applications. Characteristics. Food industry Chemical and Pharmaceutical industry Water and Sewage treatment GHM Messtechnik GmbH Hans-Sachs-Str. 26 93128 Regenstauf Germany Fon +49 (0) 9402-9383 - 0 Fax - 33 www.ghm-messtechnik.de info@ghm-messtechnik.de Product Information Analysis ph / ORP System Process connection

More information

PC60 Premium Multi-Parameter Tester (ph/ec/tds/salinity/temp.) Instruction Manual. APERA INSTRUMENTS, LLC V6.4

PC60 Premium Multi-Parameter Tester (ph/ec/tds/salinity/temp.) Instruction Manual. APERA INSTRUMENTS, LLC   V6.4 PC60 Premium Multi-Parameter Tester (ph/ec/tds/salinity/temp.) Instruction Manual APERA INSTRUMENTS, LLC www.aperainst.com V6.4 Thank you for purchasing Apera Instruments PC60 Premium Multi-Parameter Tester.

More information

Flow Fittings. for Electrochemical Sensors. B Operating Manual /

Flow Fittings. for Electrochemical Sensors. B Operating Manual / Flow Fittings for Electrochemical Sensors B 202810.0 Operating Manual 2014-05-14/00431662 Contents 1 Introduction......................................................5 1.1 Safety information.............................................................

More information

SIGNET 2760 DryLoc ph/orp Preamplifier

SIGNET 2760 DryLoc ph/orp Preamplifier SIGNET 2760 DryLoc ph/orp Preamplifier 3-2760.090 3-2760.090 (A-3/04) English SAFETY INSTRUCTIONS 1. Depressurize and vent system prior to installation or removal. 2. Confirm chemical compatibility before

More information

ecotrans Lf 01/02 Microprocessor Transmitter / Switching Device for Conductivity

ecotrans Lf 01/02 Microprocessor Transmitter / Switching Device for Conductivity Data Sheet 20.27 Page / ecotrans Lf 0/02 Microprocessor Transmitter / Switching Device for Conductivity Type 2027 Housing for DIN rail mounting (5 x 7.5 mm to EN 0 75 A.) Brief description The JUMO ecotrans

More information

Digital ph transmitter

Digital ph transmitter Digital ph transmitter Compact, remote versions for DN 15 to 200 Fully programmable ph transmitter functions for all kinds of ph-measurement tasks Large range of process connections with various fittings

More information

Conductivity Sensors ConduMax W CLS 19

Conductivity Sensors ConduMax W CLS 19 Technical Information TI 110C/07/en/12.02 50065951 Conductivity Sensors ConduMax W CLS 19 Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.1 cm 1 Application Measurement in pure and ultrapure

More information

Stamolys CA71SI. Technical Information

Stamolys CA71SI. Technical Information Technical Information Stamolys CA71SI Silicate Analyzer Compact photometric analysis system for the silicate measurement in ultrapure water and boiler feedwater Application Ultrapure water Boiler feedwater

More information

Flow Fittings. for Electrochemical Sensors. B Operating Manual /

Flow Fittings. for Electrochemical Sensors. B Operating Manual / Flow Fittings for Electrochemical Sensors B 202810.0 Operating Manual 2013-06-12/0043166 Contents 1 Introduction......................................................5 1.1 Safety information.............................................................

More information

SIGNET 3719 ph/orp Wet-Tap

SIGNET 3719 ph/orp Wet-Tap ENGLISH 3-3719.090 B-6/02 English Do not exceed maximum temperature/pressure specifications. Wear safety goggles or face shield during installation/service. Do not attempt to disassemble the retraction

More information

Environmental/Analytical LabCivil Engineering Lab Equipment

Environmental/Analytical LabCivil Engineering Lab Equipment DIGITAL PH METER Display : 3.5 Digit LED. Range : ph 0 to 14.00, mv 0 to ± 1999. Resolution : ph 0.01, mv 1. : ph ± 0.01, mv ± 1 mv. Temp. Compensation : Auto 0 to 100 deg. C., Manual 0 to 100 deg. C.

More information

JUMO ecotrans Lf 01/02

JUMO ecotrans Lf 01/02 Data Sheet 07 Page /7 JUMO ecotrans Lf 0/0 Microprocessor Transmitter/Switching Device for Conductivity Housing for DIN rail mounting (5 mm 7.5 mm to EN 075 A.) Brief description The JUMO ecotrans Lf 0/0

More information

Instruction Manual. ph Meter D-51

Instruction Manual. ph Meter D-51 Instruction Manual ph Meter D-51 Preface Thank you for purchasing the D-51 ph meter. This meter is designed with a compact body that can be held in one hand and features a water-resistant construction

More information

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05 Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing Ø

More information

JUMO tecline H2O2 JUMO tecline PAA Sensor for hydrogen peroxide and peracetic acid

JUMO tecline H2O2 JUMO tecline PAA Sensor for hydrogen peroxide and peracetic acid JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net

More information

HI Portable Waterproof Skin ph Meter INSTRUCTION MANUAL

HI Portable Waterproof Skin ph Meter INSTRUCTION MANUAL HI99181 Portable Waterproof Skin ph Meter INSTRUCTION MANUAL Dear Customer, Thank you for choosing a Hanna Instruments product. Please read this instruction manual carefully before using this meter. This

More information

User Manual Pocket Pro, Pro + ph

User Manual Pocket Pro, Pro + ph User Manual Pocket Pro, Pro + ph DOC022.52.80394 1 Specifications Specification Dimensions (W x D x H) Enclosure rating Weight Specifications are subject to change without notice. Details 37 x 30 x 170

More information

Stamolys CA71AM. Technical Information

Stamolys CA71AM. Technical Information Technical Information Stamolys CA71AM Ammonium analyzer Compact photometric analysis system for the ammonium measurement in sewage treatment plants, in drinking water and in industrial water treatments

More information

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries Product Data Sheet January 214 813-1-475, Rev FA Rosemount 875WA Magnetic Flowmeter System For Water and Wastewater Industries THE 875WA MAGNETIC FLOWMETER Rosemount reliability in a customized offering

More information

NEW QUICK CABLE-TO-SENSOR RELEASE,

NEW QUICK CABLE-TO-SENSOR RELEASE, Models 399 and 399VP Product Data Sheet PDS 71-399 October 2000 ph/orp Sensors NEW OPTIONS to meet a variety of application requirements, including: * Low ionic strength water * Processes with hydrofluoric

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET Hydrazine monitor

ABB MEASUREMENT & ANALYTICS DATA SHEET Hydrazine monitor ABB MEASUREMENT & ANALYTICS DATA SHEET 7835 Hydrazine monitor 2 78 35 H YDR AZ I N E MON I TOR DS / 78 3 5-E N RE V. L Measurement made easy Advanced transmitter Auto-ranging with remote range indication

More information

General Specifications

General Specifications General Specifications PH4/OR4 Sensor Series ph and ORP Sensors GS B10B00-01EN GENERAL Yokogawa s line of ph sensors has been strengthened by the inclusion of the polymer electrolyte ph sensor PH4P/PH4PT,

More information

Type MZ15. Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type MZ15. Operating Instructions. Bedienungsanleitung Manuel d utilisation Handheld calibration tool / Handheld cleaning tool Tragbares Kalibrierwerkzeug / Tragbares Reinigungswerkzeug Outil d'étalonnage portatif / Outil de nettoyage portatif Operating Instructions Bedienungsanleitung

More information

Screw-in resistance thermometers with plug connector

Screw-in resistance thermometers with plug connector Data Sheet 90.2004 Page 1/8 s with plug connector for temperatures from -50 to +300 C highly resistant to shock and vibration connector locked in for reliable contact, IP65 or IP69K protection available

More information

PHscan30S Pocket ph Meter Instruction Manual

PHscan30S Pocket ph Meter Instruction Manual PHscan30S Pocket ph Meter Instruction Manual BANTE INSTRUMENTS CO., LTD PHscan30S Pocket ph Meter 1 Thank you for selecting the PHscan30S pocket ph meter. This manual provides a step-by-step guide to help

More information

Immersion fittings. Brief description. Installation options Standard. Series Page 1/7. Data Sheet

Immersion fittings. Brief description. Installation options Standard. Series Page 1/7. Data Sheet JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net

More information

TITREX. One instrument for all your titration and dosing applications

TITREX. One instrument for all your titration and dosing applications TITREX One instrument for all your titration and dosing applications The digital burette TITREX is ideal for a fast and sensitive titration drop by drop. One instrument simulates all volumes up to 99.99

More information

Visit us at

Visit us at Instruction Manual testo 206 ph/ Temperature Measuring Instrument 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com 2 General Information

More information

General Specifications

General Specifications General Specifications PH4/OR4 Sensor Series ph and ORP Sensors GS B10B00-01EN GENERAL Yokogawa s line of ph sensors has been strengthened by the inclusion of the polymer electrolyte ph sensor /T, HF-resistant

More information

Signet 2760 DryLoc ph/orp Preamplifiers & Connectors

Signet 2760 DryLoc ph/orp Preamplifiers & Connectors Signet 2760 DryLoc ph/orp Preamplifiers & Connectors Features In-line integral mount and submersible installation versions Automatic temperature compensation Auto configuration for ph or ORP operation

More information

Titrette. class A precision. The next generation Digital Burette!

Titrette. class A precision. The next generation Digital Burette! The next generation Digital Burette! Titrette class A precision F I R S T C L A S S B R A N D With the Titrette bottle-top burette, you can titrate quickly and reliably with highest precision, even in

More information

Operating Instructions Dipfit CPA111

Operating Instructions Dipfit CPA111 BA00112C/07/EN/13.15 71297906 Products Solutions Services Operating Instructions Dipfit CPA111 Immersion and installation assembly for ph/orp measurement Table of contents Dipfit CPA111 Table of contents

More information

General Specifications

General Specifications General Specifications Model PH20 and FU20 ph/redox and Temperature sensor The PH20 is nicknamed "Tempress" because of the patented compensation for changes in the process temperature and pressure. This

More information

N E W! The next generation Digital Burette.

N E W! The next generation Digital Burette. N E W! Bottle-top Burette Easy dropwise titration, a compact, highprecision design, replaceable piston/cylinder assembly and an optional PC interface these are just some of the features of this successor

More information

testo 206 ph/ Temperature Measuring Instrument Bedienungsanleitung Instruction Manual

testo 206 ph/ Temperature Measuring Instrument Bedienungsanleitung Instruction Manual testo 206 ph/ Temperature Measuring Instrument Bedienungsanleitung de Instruction Manual en 18 General Information General Information Please read this document through carefully and familiarise yourself

More information

to mv Redox measurement accuracy. 173 x 195 x 103mm / 1.5kg Display

to mv Redox measurement accuracy. 173 x 195 x 103mm / 1.5kg Display ORP MEASUREMENT ACTEON 2020 TRANSMITTER Robust, watertight, easy to install, Widescreen graphic display: instant measurements, trend line, relay state, calibration state, Fast and simple intuitive programming;

More information

ELPRO Lepenik & Co. d.o.o., Ob gozdu 7c, Rogoza, 2204 Miklavž na Dravskem polju, Slovenija tel:

ELPRO Lepenik & Co. d.o.o., Ob gozdu 7c, Rogoza, 2204 Miklavž na Dravskem polju, Slovenija tel: ph & Conductivity The following pages contain a variety of instruments for the measurement of ph values as well as conductivity in microsiemens. PHX 800 as a standard testing device for the ph values.

More information

ORPscan20 Pocket ORP Tester Instruction Manual

ORPscan20 Pocket ORP Tester Instruction Manual ORPscan20 Pocket ORP Tester Instruction Manual BANTE INSTRUMENTS CO., LTD ORPscan20 Pocket ORP Tester 1 Thank you for selecting the ORPscan20 pocket ORP tester. This manual provides a step-by-step guide

More information

Combination ph/redox (ORP) Sensors

Combination ph/redox (ORP) Sensors Data Sheet Combination ph/redox (ORP) s Series AP00 User-customizable for Insertion, Flow-through, Immersion, Hot-tap Retractor ideal for Original Equipment Manufacturers and general applications Economical

More information

Optidew Vision Optical Dew-Point Meter

Optidew Vision Optical Dew-Point Meter Optidew Vision Optical Dew-Point Meter Chilled Mirror Instruments A precision hygrometer, combining drift free measurement with the flexibility of a remote sensor. Ideal for laboratory and industrial measurements,

More information

Combination ph/redox (ORP) Sensors

Combination ph/redox (ORP) Sensors Data Sheet SS/AP00_ Combination ph/redox (ORP) s AP00 Series User-customizable for Insertion, Flow-through, Immersion and Hot-tap Retractor ideal for OEMs (Original Equipment Manufacturers) and general

More information