Analysis ph / ORP. Applications. Characteristics. Food industry Chemical and Pharmaceutical industry Water and Sewage treatment

Size: px
Start display at page:

Download "Analysis ph / ORP. Applications. Characteristics. Food industry Chemical and Pharmaceutical industry Water and Sewage treatment"

Transcription

1 GHM Messtechnik GmbH Hans-Sachs-Str Regenstauf Germany Fon +49 (0) Fax info@ghm-messtechnik.de Product Information Analysis ph / ORP System Process connection Pressure range Media temperature Transmitter, digital displays, combined electrodes, inline fittings Combined electrodes with PG13.5 process thread ph-value ph, ORP-value ±1500 mv Max. 10 bar C Applications Food industry Chemical and Pharmaceutical industry Water and Sewage treatment pi-ma-ph-orp_e V

2 GHM Messtechnik GmbH Hans-Sachs-Str Regenstauf Germany Fon +49 (0) Fax info@ghm-messtechnik.de Product Information Function The measuring devices and the transducers operate with the standard ph and ORP measurement chains. The measuring devices are fitted with comprehensive monitoring functions of the measurement chains. For measuring tasks that are to be carried out over a great-er distance of 5 m to 100 m, the impedance converter ph40 is implemented. Advantage Compact version Automatic and manual calibration Impedance monitoring of glass and reference electrode of the combined electrode Monitoring the calibration interval Can be used for many standard combined electrodes Long cable length possible by impedance transmitter Temperature compensation by RTD PT100/Pt1000 sensor Device Overview Device Displays ph9648 UNICON-pH Operation Input ph, ORP, Pt100/1000 ph, ORP, Pt100/1000 Measuring range ph, ±1500 mv C ph, ±1500 mv C Output 0/4..20 ma 0/2..10 V DC max. 4 alarm outputs ma 2 alarm outputs Transmitter ph40 ph ph ph or ma GPHU ph ph ma or V DC GRMU ORP ± 2000 mv ma oder V DC Process connection Operating temperature Process pressure Page Terminals C - 3 Terminals C pol. round connector BNC- or Cinch connector BNC- or Cinch connector C C C - 10 Combined Electrodes ph AL70pH ph - PG C 3 bar 11 AL81pHT ph - PG C 10 bar 11 SL81-120pHT ph - PG C 10 bar 11 APS-X1Q2K1A ph - PG C 6 bar 11 L ph - PG C 6 bar 11 Combined electrodes ORP AL79Pt ph - PG C 3 bar 12 Pt8281HD ph - PG C 10 bar 12 Fittings EA1200 / EA PVC-U Systems C 16 bar / 22 C 13 EA1630 / EA G ¾, G C 16 bar 14 EA1730 / EA Milk pipe C 16 bar 15 DIN EA G ½, G ¾, G 1 Depending to the 16 bar 16 sensor WA G ¾ 135 C 10 bar 16 DFG PG13.5, G ¼, G1 140 C 16 bar 17 Accessories 18 Mistakes reserved, technical specifications subject to change without notice. 2 pi-ma-ph-orp_e V

3 ph and ORP Panelmeter ph9648 LED-Display 14,2 mm red Measuring range programmable ph / ±1500 mv Temperature compensation via P100/Pt1000 sensor Analog output 0/4..20 ma or 0/2..10 V for ph/orp Max. 4 alarm outputs relay or transistor The ph and ORP Panelmeter ph9648 is suitable for ph and ORP measurement in food technology, chemistry within pharmaceutical and sewage-water technology. The ph9648 operates with all common ph- and ORP electrodes. It is recommended to connect the Impedance-Converter ph40 for cable length > 5 m. Power supply Supply voltage : 230 V AC ±10 %; 115 V AC ±10 %; 24 V AC ±10 % or 24 V DC ±15 % Power consumption: max. 3.5 VA, with analog output 5 VA Operating temperature : C CE- conformity : EN 55022, EN 60555, IEC /4/5/11/13 Input ph/orp Measuring range : ph or mv R i : > Ω Input current : < A Accuracy : 0.2 % measuring value, ±2 Digit ph setup : electrode zero point ph slope mv/ph ORP setup Calibration mode Temperature Sensor : ± 200 mv : - 1- or 2-point-calibration Buffer selection possible: -Schott -WTW -Ingold (Mettler Toledo) -Puffer acc. to DIN or manual buffer input - Data entering for zero point and slope - ORP offset : RTD, Pt100 or Pt1000, (2- or 3-wire connection) Unit : programmable C, F Measuring range : C ( F) Accuracy : ± 0.1 %, ±1Digit Transmitter supply : 24 V DC, R i approx. 150 Ω, max. 50 ma (25 ma with 4 relay outputs) Display : LED red, 14.2 mm Parameter display : LED 2-digit red, 7 mm (Parameter - and output indicator) Output Relay SPDT : < 250 V AC < 250 VA < 2 A, < 300 V DC <50 W < 2 A Transistor : < 35 V AC/DC, max.100 ma, short-circuit-proof Analog output active : 0/4..20 ma burden 500 Ω; 0/2..10 V burden > 500 Ω, isolated automatic output changing (burden dependent) Analog output passive : ma, ext. burden = RA[Ω] (U B-5 V) 0,02 A ; supply voltage V DC Accuracy : 0.1 % Panel case Weight Connection Protection class Connection diagram input : DIN 96x48 mm, material PA6-GF; UL94V-0 : Front 96x48 mm, mounting depth 100 mm, : max. 390 g : clamp terminals, 2.5 mm² single wire, 1.5 mm² flex wire, AWG14 : Front IP65, terminals IP20, finger save acc. to BGV A3 Transmitter supply pi-ma-ph-orp_e V

4 ph Terminal strip A 13 input ph / ORP electrode, temperature compensation via Pt100 / Pt Terminal strip B 00 not installed 2R 2 relay outputs 2T 2 electronic outputs 3. Terminal strip C 00 not installed 2R 2 relay outputs 2T 2 electronic outputs AO analog output 0/4..20 ma, 0/2..10 V DC 2A 2 analog outputs ma passive 4. Terminal strip B supply voltage V AC ±10 % 50-60Hz V AC ±10 % 50-60Hz 4 24 V AC ±10 % 50-60Hz 5 24 V DC ±15 % 5. Options 6. Unit appears in the unit field 7. Additional text above the display (3x90 mm HxW) Connection diagram for terminal strips B-D see page 5 Accessories see page 18 Connection examples ph pi-ma-ph-orp_e V

5 Connection Diagrams X9648, Terminals B-D Terminal strips B, C, D Terminal strip A belongs to each article. pi-ma-ph-orp_e V

6 ph and ORP Converter UNICON -ph Field or head mounting Measuring range programmable ph / ±1500 mv Temperature compensation via P100/Pt1000 sensor Analog output ma for ph/orp and temperature 2 alarm outputs, transistor The ph and ORP converter UNICON-pH is suitable for ph and ORP measurement in food technology, chemistry within pharmaceutical and sewage-water technology. The converter works with all common ph- and ORP electrodes. Power supply Supply voltage : V DC, 2-wire Operating temperature : C CE- conformity : EN 55022, IEC /4/5 Input ph/orp Output signal : ma Burden : RA[Ω] (U B-14 V) 0,02 A Measuring range : ph or mv R i : >10 12 Ω Input current : <10-12 A Accuracy : 0.2 % measuring value, ±2 Digit Electrode zero point : 7.00 ph Slope : mv/ph ORP setup : ± 200 mv Calibration mode : - 1- or 2-point-calibration buffer selection possible : -Schott - WTW -Ingold (Mettler Toledo) -Buffer acc. to DIN or manual buffer input - Data entering for zero point and slope - ORP setup Temperature Output signal : ma Burden : RA[Ω] (U B-14 V) 0,02 A Temperature sensor : Pt100 or Pt1000, (2-wire) Unit : programmable C, F Measuring range : C ( F) Accuracy : ± 0.1 %, ±1Digit Glass impedance : 0..1 GΩ (temperature compensated) Detection range : GΩ (non compensated) Accuracy : ± 20 % Reference imped. : kω (non compensated) Monitoring of the calibration interval : days Display : LCD-dot matrix, 3.8 mm characters 2 lines 16 characters each Alarm outputs Transistor : V DC<, max.60 ma, with short-circuit-proof Voltage drop : < 2 V Range switch Ri : >10 kω MB1 active : U = 0..3 V DC MB2 active : U = V DC Case : Head-field case Material : Polyamide fiber glass PA6-GF/GK 15/15, front foil polyester : 100 x 100 x 60 mm (WxHxD) Weight Connection Protection class Connection diagram : max. 360 g : screw terminals pressure plate, 2.5 mm² flexible, 4 mm² single wire connection cable : IP65, terminals IP20 acc. to BGV A3 For supplying the converter use terminals 9 and 10 as shown. If the converter is used form monitoring only, terminals 9 and 10 must be connected directly to the supply voltage. Continue next page Outside brackets (only field case) Cable connector for conductive cell (only field case) Cable gland M20x1.5 for cable diameter 6-12 mm 6 pi-ma-ph-orp_e V

7 UNICON-pH Model 1 output ma for ph/orp, 2 electronic alarm outputs 2 as 1, but 2 nd measuring range for ph/orp, output ma for temperature, monitoring of the glass impedance, reference electrode and the calibration interval 2. Mounting 01 head mounting, on the electrode 02 field mounting, separate connection cable see page Reference system 3 all systems with electrode zero point ph7.00 e.g. silver/silver chloride 4. Temperature compensation 13 Pt100/Pt1000 sensor via software selectable 5. Options Accessories see page 18 Connection diagram input UNICON-pH

8 ph Head-Transmitter ph40 ph40 ph-electrode Measuring range ph 2-wire transmitter ma Error free measurement up to 100 m Connection diagram Type 0 Type 2 The head transmitter is designed for direct mounting on the phelectrode with input lock nut connector B. The output signal is located at output connector A. For ph-electrodes with integrated RTD are the lines connected through. Power supply Supply voltage : V DC output 0 : V DC output 2 Operating temperature : C Input ph/orp Measuring range : ph / ± 1500 mv Input resistance Output Type 0 Type 2 : >10 12 Ω Accuracy : type 0 = 0.01 % type 2 = 0.2 % Case Material Weight Process connection Electrical connection Material Protection class : 1:1 transfer of the ph-signal with low output impedance, error free measurement up to 100 m : ma, 2-wire technology in the range ph depending at 25 C, zero-point ph 7.0, slope 59.2 mv/ph, not compensated : PVC-U : approx. 100 g : S7 or SMEK plug : 8 pole round socket, M12x1 : brass plated : IP ph (A) (B) 1. Output ph = 1:1 signal transfer ma = ph 2. Input plug B process connection for ph-electrode 1 SMEK socket 2 S7 socket 3. Options Accessories connection cable with 8 pole cable socket brass plated and pigtail, PU-cable SKM8E-02 2 m IP67 SKM8E-05 5 m IP67 SKM8E m IP67 SKM8E m IP67 other length on request 8 pole cable socket for self assembling (A) (B) 8 pi-ma-ph-orp_e V

9 GREISINGER electronic GmbH Hans-Sachs-Straße Regenstauf Germany Fon +49 (0) Fax info@greisinger.de Product Information ph Transmitter GPHU GPHU14MP With on-site display and electric isolation Automatic and manual temperature compensation 2-point calibration The GPHU is used for regulating, measuring and monitoring tasks e.g. in environmental and medical technology. Every standard ph electrode can be used together with the GPHU, because the device has both, a BNC and a Cinch socket. Additionally it provides two banana sockets for a Pt1000 probe for temperature compensation. The values for temperature can also be entered manually via buttons. Measuring range : ph Accuracy : 0.02 ph ±1 digit (at nominal temperature 25 C) Output signal : ma (2-wire) V (3-wire) Electric isolation : input electrically isolated Power supply : V DC for ma V DC for V Permissible burden : R A [Ω] = (U V [V] - 12V) / 0.02 A Permissible load : R L > 3000 Ω Electrode : any standard ph electrode is suitable (electrode not included) Input resistance : Ω Electrode socket : BNC / Cinch Temp. compensation : C, manually selectable via buttons or automatically via external Pt1000 probe Temp.connection socket : 2x banana socket Ø 4 mm, for Pt1000 probe Display : 10 mm high, 4-digit LCD display Electric connection : elbow-type plug (EN /A) Housing : ABS Working temperature : C Protection class : IP65 (except electrode and temperature socket) 1. Electrode socket BNC BNC socket CINCH Cinch socket 2. Output signal A ma V V 3. Option MB limited measuring range (please state the desired range, e.g.: ph) Ordering example: GPHU-14MP-BNC-A1-00 Accessories GTF 2000 WD-B Water-proof Pt1000 temperature probe with 2 banana plugs Ø 4 mm, measuring range: C GE 100 Standard electrode, Cinch plug measuring range: ph temperature range: C; > 200 μs/cm, not pressure resistant, 1 m cable GE 100 BNC Standard electrode, BNC plug (specifications: p.r.t. GE 100) GE 117 ph electrode with integrated Pt1000 sensor 1x BNC plug and 1x banana plug Ø 4 mm and thread PG 13.5 pressure resistant up to 6 bar PG 13.5 Plug-on thread adapter for pressureless use with external thread PG 13.5 (can be attached to any electrode) further accessories upon request pi-ma-ph-orp_e V

10 GREISINGER electronic GmbH Hans-Sachs-Straße Regenstauf Germany Fon +49 (0) Fax info@greisinger.de Product Information ORP Transmitter GRMU Electrically isolated Optional on-site display The GRMU is suited for regulating, measuring and monitoring tasks e.g. at environmental and medical technology Every standard ORP electrode can be used in combination with the GRMU that provides alternatively a BNC or Cinch socket. Measuring range Accuracy Output signal Electric isolation Power supply Permissible burden Permissible load Electrode : ±2000 mv : 0.2 % FS : ma (2-wire) V (3-wire) : input electrically isolated : V DC for ma V DC for V : R A [Ω] = (U V [V] - 12V) / 0.02 A : R L > 3000 Ω : any standard ORP electrode is suitable (electrode not included) GRMU2000MP Electrode socket BNC BNC socket CINCH Cinch socket 2. Output signal A ma V V 3. Option VO on-site display (display) MB limited measuring range (please state the desired range) Ordering example: GRMU-2000MP-CINCH-A1-VO Accessories GE 105 ORP electrode with Cinch plug and buffer solution Measuring range: ±2000 mv Temperature range: C; > 25 μs/cm, not pressure resistant, 1 m cable PG 13.5 Plug-on thread adapter for pressureless use with external thread PG 13.5 (can be attached to any electrode) Input resistance : Ω Electrode socket : BNC / Cinch Display : 10 mm high, 4-digit LCD display Electric connection : elbow-type plug (EN /A) Housing : ABS Working temperature : C Protection class : IP65 (except electrode socket) 10 pi-ma-ph-orp_e V

11 Standard Combined ph and ORP Electrodes ph Electrodes Type AL70pH-00 AL81pHT-00 SL81-120pHT-00 APS-X1Q2K1A-00 L9080 Functional range ph ph ph ph ph Field of application Water Water, Waste water Food (sterilizing possible) Refrigeration engineering Ultra pure water, boiler feed water Operating temperature C C C C C Max. process pressure 3 bar 10 bar 10 bar 6 bar 6 bar Mounting length 120 mm 120 mm 120 mm 120 mm 120 mm Process connection PG13.5 PG13.5 PG13.5 PG13.5 PG13.5 Temperature sensor - RTD, Pt1000 RTD, Pt Electrical connection* S7 SMEK SMEK S7 S7 Reference system Silver/silver chloride (Ag/AgCl) electrode zero point ph7.00 Reference filling solution GEL Polymer (Referid) Gel Gel Liquid Diaphragm ceramic KPG ceramic PTFE ceramic Min. conductivity of the media 50 µs/cm 50 µs/cm 50 µs/cm 50 µs/cm < 1 µs/cm Mounting position * Connection cable see page 18 Mounting position pi-ma-ph-orp_e V

12 Combined ORP electrodes Type AL79Pt-00 Pt8281HD-00 Functional range ph ph Field of application Environmental engineering, disinfection Environmental engineering, disinfection Operating temperature C C Max. process pressure 3 bar 10 bar Mounting length 120 mm 120 mm Process connection PG13.5 PG13.5 Temperature sensor - - Electrical connection* S7 S7 Reference system Silver/silver chloride (Ag/AgCl) electrode zero point ph7.00 Reference filling solution Polymer (Referid) Polymer (Referid) Diaphragm ceramic KPG Min. conductivity of the media 50 µs/cm 50 µs/cm Mounting position, see page before * Connection cable see page Utilization notes for combined ph and ORP electrodes 1. Co0mbined ph and ORP electrodes are supplied with a protective cap, which is filled with a 3mol KCL solution. In this condition the electrodes can be stored max. 1 year. Therefore the protective cap should be removed only just before installation and use. 2. The shank of the combined electrode consists of glass and is easily fragile. At installation it must be ensured absolutely that the tube does not push anywhere. 3. Because the characteristics deviate from the ideal line, for the precise measurement it is necessary to calibrate the electrode after start-up and then in regular time intervals. 4. A combined electrode must not drain at the active tip, otherwise it becomes useless. To recover the active tip of the electrode it can be dipped for about 24 hours into a 3mol KCL storage solution. Subsequently, a calibration is necessary, because zero point and slope may have been drifted. 5. In dirty and containing protein media a cleaning of the electrodes is necessary occasionally. When using purpose we offer a special cleaning solution. After cleaning, the electrodes must be rinsed with water. Attention note! ph and ORP electrodes only have a limited life of operating. It depends on the field of application such as medium, pressure and temperature. It can differ between a number of weeks and several years. There are special cases, of environment conditions where operating life will be only some days. Characteristic and response time will change by aging. Up to a certain aging point an error can be compensated by using electronic circuit (e.g. Converter UNICON-pH). Combined ph and ORP electrodes are articles of consumption and no subject to a common guarantee. Retaking or exchanges are generally excluded. Our offer includes free technical support for selection optimal combined ph and ORP electrodes. Beside listed standard electrodes we can also offer special models on customers request. 12 pi-ma-ph-orp_e V

13 In-line Fitting EA1200 / EA2200 EA1200 EA2200 For flow fittings with outer pipe diameter from 20mm up to 63 mm. This In-line fitting has been designed for electrochemical cells like ph/orp-, conductivity-cells with PG13.5 process connection. It protects the sensor and ensures a proper measurement. The fitting fits for operating at the flow-fitting DFA32. The application field includes swimming pools technology and drinking water measurement. Tip protection Flow fitting DFA32 [mm] Sensor connection : PG13.5 Process connection : screw cap for adhesive coupling Process material : PVC-U acc. to DIN 8061 and 8062 Screw cap : PVC-U Operating temperature : C Process pressure : max. 16 bar at 22 C Pressure-temperature table PVC-U d H A E EA Model 1200 head mounting at UNICON-pH, incl. cap nut 2200 field mounting, incl. cap nut 2. Sensor type 0 standard ph / ORP combined-electrodes 3. Options 01 with integrated tip protection (only for ph and ORP combined-electrodes) Accessories flow fitting DFA32 material PVC-U DFA outer pipe diameter d=20 mm DFA outer pipe diameter d=25 mm DFA outer pipe diameter d=32 mm DFA outer pipe diameter d=40 mm DFA outer pipe diameter d=50 mm DFA outer pipe diameter d=63 mm pi-ma-ph-orp_e V

14 In-line Fitting EA1630 / EA2630 EA1630 EA2630 Compact fitting with Whitworth process connection acc. to DIN ISO 228. This In-line fitting has been designed for electrochemical cells like ph/orp-, conductivity-cells with PG13.5 process connection. It protects the sensor and ensures a proper measurement. The fitting is conceived for the application in the chemical industry. Tip protection Process connection A B G ¾ A Ø23.5 G 1 A Ø25 Process connection : pipe thread acc. to DIN ISO 228 Process material : PVDF Operating temperature : C steam sterilization 140 C < 1 h Process pressure : max. 16 bar EA Model 1630 head mounting at UNICON-pH 2630 field mounting 2. Process connection (A) G ¾ A G 1 A 3. Sensor type 0 standard ph / ORP combined-electrodes 4. Options 01 with integrated tip protection (only for ph and ORP combined-electrodes) 14 pi-ma-ph-orp_e V

15 In-line Fitting EA1730 / EA2730 EA1730 EA2730 Hygienic fitting; material PVDF for milk-pipe connection acc. to DIN This In-line fitting has been designed for electrochemical cells like ph/orp-, conductivity-cells with PG13.5 process connection. It protects the sensor and ensures a proper measurement. The application field includes food and chemical technology. Tip protection EA Process connection: milk pipe acc. to DIN Process material : PVDF FDA compliant Cap nut : stainless steel Operating temperature : C steam sterilization 140 C < 1 h Process pressure : max. 16 bar 1. Model 1730 head mounting at UNICON-pH, incl. Cap nut 2730 field mounting, incl. cap nut 2. Process connection DN25 DN40 DN50 DN65 3. Sensor type 0 standard ph / ORP combined-electrodes 4. Options 01 with integrated tip protection (only for ph and ORP combined-electrodes) pi-ma-ph-orp_e V

16 In-line Fitting EA2650 Change Fitting WA120 This In-line fitting has been designed for electrochemical cells like ph/orp-, conductivity-cells with PG13.5 process connection. Material : stainless steel , seal Viton Process pressure : max. 16 bar Operating temperature : depends to the sensor Process connection : G ½ A, G ¾ A, G 1 A Change fittings makes re-movement and replacement of ph and ORP electrodes under process (In-line) very simple. The fitting is designed for cells/electrodes with process thread PG13.5 and a mounting length of 120 mm. The concerned cycle will not disturb or interrupted at any time. Process material : stainless steel , seal Viton Case material : PP Process pressure : max. 10 bar Operating temperature : max. 135 C Process connection : G ¾ A Installation length : 120 mm EA WA G3/4A Model 2650 field mounting 2. Process connection (A) G ½ A G ¾ A G1 A 3. Cells/combined electrodes 0 for standard ph / ORP electrodes 4. Options 1. Model 1 for sensors with 120mm mounting length 2. Process material E stainless steel DIN Options Viton is a registered trademark of DuPont 16 pi-ma-ph-orp_e V

17 Flow-Tank DFG Accessories Lid with 3 x PG13.5 process connections and blind gland VS For continuous analysis measurement with ph-, ORP-cells in liquid media with installation length of max. 120 mm. Material : stainless steel Process pressure : max. 16 bar Operating temperature : max. 140 C Process connection : PG 13.5, G ¼ B or G1A Inlet-, outlet : clamping sleeve for pipes 10x2 mm Tank diameter : 54 mm DFG Model 50 measuring tank D=54 mm 2. Process connection 1 x PG13.5 *X = 45 mm 3 x PG13.5 *X = 45 mm 3 x G ¼ B *X = 45 mm 1 x G 1 A *X = 27 mm 3. Options Accessories (stainless steel ) MP50 mounting plate incl. Mounting parts RSB50 2 clamp bails incl. Bolt nuts VS PG13,5 blind glands PG13.5 pi-ma-ph-orp_e V

18 Connection cable Connection cable 1 for electrodes with S7-connector Order no. Length [m] Protection class S IP67 S IP67 Calibrations tools WTW technical buffer, 1000 ml with dosing container Order no. PH-buffer value TEP TEP TEP WTW ORP-buffer 250 ml bottle Order no. RH28 Buffer value [mv] 427 (ph7) Connection cable 2 for electrodes with S7-connector at UNICON-pH, head mounting. Order no. Length [m] Protection class S7-K - - Storage solutions 250 ml DURAN-glass bottle, 3 mol KCL sterilized Order no. ph-al-250 Connection cable 3 for electrodes with SMEK-connector Order no. Length [m] Protection class SMEK IP67 SMEK IP67 SMEK IP67 SMEK IP67 SMEK IP67 (not used cables could be cutting) Connection cable 4 for electrodes with SMEK-connector at UNICON-pH, head mounting. Cleaning solution 250 ml DURAN-glass bottle, Pepsin / hydrochloride acid Order no. ph-rl-250 Calibration container for in-front-calibration material PMMA with level sign(20ml) and screw-cap PG13.5. (the ph-electrode must be screwed-in with the filled container). Order no. ph-kr-250 Order no. Length [m] Protection class SMEK-6-K - - Cleaning container 250 ml, to rinse the electrodes with water, material PP Order no. ph-sb pi-ma-ph-orp_e V

19 pi-ma-ph-orp_e V

20 Product overview Laboratory Instrumentation 20 pi-ma-ph-orp_e V

Analysis ph / ORP. Characteristics System. Applications Food industry Chemical and Pharmaceutical industry Water and Sewage treatment

Analysis ph / ORP. Characteristics System. Applications Food industry Chemical and Pharmaceutical industry Water and Sewage treatment GHM GROUP CORPORATE GHM Messtechnik GmbH Schloßstr. 6 88453 Erolzheim GERMANY Phone +49 7354 937233-76 Fax +49 7354 937233-88 System Process connection Pressure range Media temperature Transmitter, digital

More information

GHMsilverline Handheld Instruments

GHMsilverline Handheld Instruments GHM Messtechnik GmbH Hans-Sachs-Str. 26 93128 Regenstauf Germany Fon +49 (0) 9402-9383 - 0 Fax - 33 www.ghm-messtechnik.de info@ghm-messtechnik.de Handheld Instruments Characteristics System Measurands

More information

Humidity. Characteristics. Applications. Capacitive humidity measurement, temperature measurement via Pt100/Pt1000 Sensor

Humidity. Characteristics. Applications. Capacitive humidity measurement, temperature measurement via Pt100/Pt1000 Sensor GHM Messtechnik GmbH Sales Center International Schloßstraße 6 88453 Erolzheim Germany Fon +49-7354-937233-0 Fax -88 www.ghm-messtechnik.de info@ghm-messtechnik.de Humidity Characteristics Applications

More information

Digital ph transmitter

Digital ph transmitter Digital ph transmitter Compact, remote versions for DN 15 to 200 Fully programmable ph transmitter functions for all kinds of ph-measurement tasks Large range of process connections with various fittings

More information

Flow - magnetic inductive - probe form

Flow - magnetic inductive - probe form GHM Messtechnik GmbH Hans-Sachs-Str. 6 938 Regenstauf Germany Fon +9 (0) 90-9383 - 0 Fax - 33 www.ghm-messtechnik.de info@ghm-messtechnik.de Flow - magnetic inductive - probe form Characteristics System

More information

Digital ph transmitter

Digital ph transmitter Digital ph transmitter Compact, remote versions for DN 15 to 200 Fully programmable ph transmitter functions for all kinds of ph-measurement tasks Large range of process connections with various fittings

More information

Magnetic Inductive Flow

Magnetic Inductive Flow GHM Messtechnik GmbH Hans-Sachs-Str. 26 93128 Regenstauf Germany Fon +49 (0) 9402-9383 - 0 Fax +49 (0) 9402-9383 - 33 www.ghm-messtechnik.de info@ghm-messtechnik.de Magnetic Inductive Flow Characteristics

More information

Pressure. Applications. Characteristics. Differential pressure Overload pressure, Vacuum, Absolute pressure, Flow ±0.3 mbar..

Pressure. Applications. Characteristics. Differential pressure Overload pressure, Vacuum, Absolute pressure, Flow ±0.3 mbar.. GHM GROUP CORPORATE GHM Messtechnik GmbH Schloßstr. 6 88453 Erolzheim GERMANY Phone +49 7354 937233-76 Fax +49 7354 937233-88 Product Information information Sensors and Instrumentation Characteristics

More information

Beck. The differential pressure transmitter for air with IP65

Beck. The differential pressure transmitter for air with IP65 Beck. The differential pressure transmitter for air with IP65 Differential pressure transmitter 985 with IP65 General description The differential pressure transmitters of the 985 series are used to measure

More information

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram Data Sheet 403025 Page 1/10 JUMO dtrans p20 Process pressure transmitter Brief description The JUMO dtrans p20 pressure transmitter with HART interface combines maximum precision with easy operation. It

More information

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids For use in large diameter pipes as an economical solution for flow measurement Flow rate measurement

More information

JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering

JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering Data Sheet 22943 Page 1/9 JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering Brief description The sensor detects the electrolytic conductivity of a process liquid.

More information

Magnetic-Inductive Flow Meter FMI

Magnetic-Inductive Flow Meter FMI SENSORS FOR FOOD AND BIO. Product information FMI-C, FMI-R FOOD Magnetic-Inductive Flow Meter FMI Application/Specified usage Magnetic-inductive flowmeter for the measurement of flow rate and volume in

More information

Paddle-wheel flow controller for On/Off control

Paddle-wheel flow controller for On/Off control Paddle-wheel flow controller for On/Off control Type 8032 can be combined with... Indication, monitoring, transmitting and On/Off control in one device Programmable outputs (transistor or relay) Automatic-calibration:

More information

ScienceLine ph combination electrodes

ScienceLine ph combination electrodes Scienceine ph combination electrodes ph combination electrodes with plug head and fixed cable Reference silver/silver chloride system: (See Remarks) Shaft material: glass Zero point: ph = 7.0 ± 0.3 Electrolyte:

More information

testo 206 ph/ Temperature Measuring Instrument Bedienungsanleitung Instruction Manual

testo 206 ph/ Temperature Measuring Instrument Bedienungsanleitung Instruction Manual testo 206 ph/ Temperature Measuring Instrument Bedienungsanleitung de Instruction Manual en 18 General Information General Information Please read this document through carefully and familiarise yourself

More information

JUMO DELOS SI. Precision pressure transmitter with switching contacts and display. Application. Brief description. Key features.

JUMO DELOS SI. Precision pressure transmitter with switching contacts and display. Application. Brief description. Key features. Data sheet 405052 Page 1/10 JUMO DELOS SI Precision pressure transmitter with switching contacts and display Application Food & pharma CIP/SIP systems Machine and system construction Air conditioning and

More information

Continuous level sensor NSK

Continuous level sensor NSK SENSORS FOR FOOD AND BIOPHARMA. Product Information NSK-157, -357, -358 FOOD Continuous level sensor NSK Application Continuous level monitoring in metallic vessels up to 3 m in height Ideal for highly

More information

Orbipore CPS91 and CPS91D

Orbipore CPS91 and CPS91D Technical Information Orbipore CPS91 and CPS91D ph electrodes, analog or with digital Memosens technology With open aperture for heavily soiled media, optional built-in temperature sensor Application Chemical

More information

Magnetic-Inductive flow Meter fmi

Magnetic-Inductive flow Meter fmi 1 Product information fmi-c, fmi-r f o o d P H A R M A Magnetic-Inductive flow Meter fmi Application / Specified Usage Certification Magnetic-inductive flowmeter for the measurement of flow rate and volume

More information

JUMO dtrans p20 DELTA

JUMO dtrans p20 DELTA Data Sheet 403022 Page 1/9 JUMO dtrans p20 DELTA Differential pressure transmitter Brief description The JUMO dtrans p20 DELTA differential pressure transmitter with HART interface combines maximum precision

More information

JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering

JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering Data Sheet 22943 Page 1/9 JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering Brief description The sensor detects the electrolytic conductivity of a process liquid.

More information

Orbisint CPS12/CPS12D/CPS13

Orbisint CPS12/CPS12D/CPS13 Technical Information Orbisint CPS12/CPS12D/CPS13 ORP electrodes, analog and digital with Memosens technology and reference electrode Each with dirt-repellent PTFE diaphragm for standard applications in

More information

Continuous level sensor NSK

Continuous level sensor NSK SENSORS FOR FOOD AND BIOPHARMA. Product Information NSK-187, -387, -388 FOOD Continuous level sensor NSK Application Continuous level monitoring in metallic vessels up to 2.5 m in height Ideal for highly

More information

Ceraliquid CPS42/CPS42D/CPS43

Ceraliquid CPS42/CPS42D/CPS43 Technical Information Ceraliquid CPS/CPSD/CPS ORP electrodes, analog and digital with Memosens technology and reference electrode Each with ceramic diaphragm and liquid KCl electrolyte Application Media

More information

Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids

Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids Flow rate measurement is independent of density, temperature, viscosity and pressure Pulsed coil excitation to

More information

Visit us at

Visit us at Instruction Manual testo 206 ph/ Temperature Measuring Instrument 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com 2 General Information

More information

JUMO tecline CR Electrolytic Conductivity Cells in stainless steel or titanium

JUMO tecline CR Electrolytic Conductivity Cells in stainless steel or titanium Page 1/10 JUMO tecline CR Electrolytic Conductivity Cells in stainless steel or titanium 202924 Series (formerly 2 EL6... Series) 2-electrode system for ranges from 0.05 µs/cm to 1 ms/cm large variety

More information

JUMO MIDAS Pressure transmitter

JUMO MIDAS Pressure transmitter Phone: +44 19 635533 Fax: +44 19 6356 Data Sheet 401001 Page 1/5 JUMO MIDAS Pressure transmitter Brief description Pressure transmitters are used for measuring the relative (gauge) pressure in liquids

More information

MEASUREMENT AND INSTRUMENTATION FLS

MEASUREMENT AND INSTRUMENTATION FLS MEASUREMENT AND INSTRUMENTATION FLS The FLS Measurement and Instrumentation line consists of a comprehensive range of Flow, ph, ORP, Conductivity Sensors, Monitors and Transmitters. INDEX SYSTEM SELECTION

More information

Pressure transmitters for industrial applications Type MBS 4510

Pressure transmitters for industrial applications Type MBS 4510 Pressure transmitters for industrial applications Type MBS 4510 Technical brochure Features Designed for use in severe industrial environments Enslosure and wetted parts of acid-resistant stainless steel

More information

Insertion magnetic inductive flowmeter

Insertion magnetic inductive flowmeter Insertion magnetic inductive flowmeter Sensor without moving parts Flowmeter with On/Off control Application related calibration by Teach-In function Clean in place (CIP) FDA-compliant materials Type 8041

More information

Pressure transmitter for industrial applications Type MBS 4510

Pressure transmitter for industrial applications Type MBS 4510 MAKING MODERN LIVING POSSIBLE Data sheet Pressure transmitter for industrial applications Type MBS 4510 The high accuracy flush diaphragm pressure transmitter MBS 4510 is designed for use in non-uniform,

More information

ProMinent. ProMinent D4a Metering Pumps with built-in proportional controllers

ProMinent. ProMinent D4a Metering Pumps with built-in proportional controllers D4a Metering Pumps with built-in proportional controllers A series of solenoid-driven metering pumps with built-in ph controller, oxidation-reduction potential (Redox) controller or chlorine controller.

More information

Product information Hygienic Design Turbidity

Product information Hygienic Design Turbidity www.ghm-group.de Product information Hygienic Design Turbidity Characteristics Application System Optical Turbidimeter Processing Indication, switching, measuring Process connection Welded nozzle, Milk-pipe

More information

Flow - rotor, inline model

Flow - rotor, inline model GHM Messtechnik GmbH Hans-Sachs-Str. 26 93128 Regenstauf Germany Fon +49 (0) 9402-9383 - 0 Fax - 33 www.ghm-messtechnik.de info@ghm-messtechnik.de Flow - rotor, inline model Characteristics System Flow

More information

Pipe surface resistance thermometer, for clamping Model TR57-M, miniature design

Pipe surface resistance thermometer, for clamping Model TR57-M, miniature design Electrical temperature measurement Pipe surface resistance thermometer, for clamping Model TR57-M, miniature design WIKA data sheet TE 60.57 Applications Sanitary applications Food and beverage industry

More information

Pressure transmitter for general industrial purposes MBS 3000 and MBS 3050

Pressure transmitter for general industrial purposes MBS 3000 and MBS 3050 Data sheet Pressure transmitter for general industrial purposes MBS 3000 and MBS 3050 The compact pressure transmitter, type MBS 3000, is designed for use in almost all industrial applications, and offers

More information

JUMO ecotrans Lf 01/02

JUMO ecotrans Lf 01/02 Data Sheet 07 Page /7 JUMO ecotrans Lf 0/0 Microprocessor Transmitter/Switching Device for Conductivity Housing for DIN rail mounting (5 mm 7.5 mm to EN 075 A.) Brief description The JUMO ecotrans Lf 0/0

More information

Technical Information Ceraliquid CPS41D and CPS41

Technical Information Ceraliquid CPS41D and CPS41 TI00079C/07/EN/13.15 71277561 Products Solutions Services Technical Information Ceraliquid CPS41D and CPS41 ph electrodes, digital with Memosens technology, and analog For process engineering with ceramic

More information

JUMO MIDAS C18 SW. OEM pressure transmitter - seawater. Applications

JUMO MIDAS C18 SW. OEM pressure transmitter - seawater. Applications Delivery address: Mackenrodtstraße 4 Phone: +49 66 600-0 Fax: +49 66 600-607 Phone: +44 79 655 Fax: +44 79 656 Data Sheet 400 Page /6 JUMO MIDAS C8 SW OEM pressure transmitter - seawater Applications Water

More information

Cleanfit H CPA475. Technical Information. Retractable assembly for ph, ORP measurement under sterile conditions

Cleanfit H CPA475. Technical Information. Retractable assembly for ph, ORP measurement under sterile conditions Technical Information Cleanfit H CPA475 Retractable assembly for ph, ORP measurement under sterile conditions Application Food industry Beverage industry Pharmaceutical industry Drinking water The retractable

More information

better measurement Simply a question of

better measurement Simply a question of Simply a question of better measurement SCHMIDT Flow Sensor SS 2.415 and SS 2.515 The tried and tested measurement experts for the monitoring of laminar flows extremely precise and quickly installed Industrial

More information

Level limit switch Series CN 4000 Selection list. Specifications 2. Applications 4

Level limit switch Series CN 4000 Selection list. Specifications 2. Applications 4 Table of contents Page Specifications 2 Applications 4 ------------------------------------------------------------------------------------------------------------ CN 4020 5 Short extension length ------------------------------------------------------------------------------------------------------------

More information

Pressure transmitters for heavy-duty applications MBS 2000 and MBS 2050

Pressure transmitters for heavy-duty applications MBS 2000 and MBS 2050 Data sheet Pressure transmitters for heavy-duty applications MBS 2000 and MBS 2050 The compact heavy duty pressure transmitters MBS 2000 and MBS 2050 are designed for use in hydraulic applications. MBS

More information

Pressure transmitter for general industrial purposes Type MBS 3000 and MBS 3050

Pressure transmitter for general industrial purposes Type MBS 3000 and MBS 3050 MAKING MODERN LIVING POSSIBLE Data sheet Pressure transmitter for general industrial purposes Type MBS 3000 and MBS 3050 The compact pressure transmitter, type MBS 3000, is designed for use in almost all

More information

Pressure transmitters for heavy duty applications MBS 3200 and 3250

Pressure transmitters for heavy duty applications MBS 3200 and 3250 Data sheet Pressure transmitters for heavy duty applications MBS 3200 and 3250 The compact high temperature pressure transmitter MBS 3200 is designed for use in hydraulic and almost all industrial applications,

More information

Pressure transducer DMU 01K Compact version

Pressure transducer DMU 01K Compact version Pressure transducer DMU 01K Compact version Dimensions (in mm) Wiring diagram 8 Application Special OEM unit. For electronic pressure measurement in industrial or HVAC applications (such as hydraulic,

More information

PH60 Series Premium ph Testers

PH60 Series Premium ph Testers PH60 Series Premium ph Testers Instruction Manual PH60 ph Tester PH60S Spear ph Tester PH60F Flat ph Tester APERA INSTRUMENTS (Europe) GmbH www.aperainst.de v5.6 Thank you for purchasing the Apera Instruments

More information

Differential Pressure Sensors

Differential Pressure Sensors 1 910 1910P01 Differential Pressure Sensors for air or nonaggressive gases QBM66... Pressure-linear characteristic with selectable pressure measuring range Operating voltage AC 24 V or DC 13.5...33 V Output

More information

Compact Pressure Transmitter DAN-HH

Compact Pressure Transmitter DAN-HH 1 Product Information DAN-HH Compact Pressure Transmitter DAN-HH Application / Specified Usage Authorizations Pressure measurement in pipes and vessels High Temperature applications up to 150 C permanent

More information

Pressure transmitter for industrial applications Type MBS 4500

Pressure transmitter for industrial applications Type MBS 4500 MAKING MODERN LIVING POSSIBLE Data sheet Pressure transmitter for industrial applications Type MBS 4500 The high accuracy pressure transmitter MBS 4500 is designed for use in almost all industrial applications,

More information

Level limit switch Series RF 3000 Selection list

Level limit switch Series RF 3000 Selection list Table of content Page Overview P2 Applications P4 ------------------------------------------------------------------------------------------------------------- RF 3100 Standard version P6 -------------------------------------------------------------------------------------------------------------

More information

Orbisint CPS11 and CPS11D

Orbisint CPS11 and CPS11D Technical Information Orbisint CPS11 and CPS11D ph electrodes, analog or with digital Memosens technology For standard applications in process and environment technology, with dirt-repellent PTFE diaphragm,

More information

Level Sensor with G1/2" Thread Hygienic

Level Sensor with G1/2 Thread Hygienic SENSORS FOR FOOD AND BIOPHARMA. Product Information NVS-141, -143, -146, -161, -163, -166, -181, -183, -186 FOOD Level Sensor with Thread Hygienic Application/intended use Limit detection of aqueous and

More information

Ceraliquid CPS41 and CPS41D

Ceraliquid CPS41 and CPS41D Technical Information Ceraliquid CPS and CPSD ph electrodes, analog and digital with Memosens technology With ceramic diaphragm and liquid KCl electrolyte, optional built-in temperature sensor Application

More information

Level Sensor with M12 Thread Hygienic

Level Sensor with M12 Thread Hygienic SENSORS FOR FOOD AND BIOPHARMA. Product Information NVS-041, -043, -046, -061, -063, -066, -081, -083, -086 FOOD Level Sensor with M12 Thread Hygienic Application/intended use Limit detection of aqueous

More information

SITRANS P measuring instruments for pressure

SITRANS P measuring instruments for pressure Overview Siemens AG 009 Supplementary electronics for 4-wire connection Design Dimensions (W x H x D) in mm (inch) Electrical connection 80 x 10 x 60 (3.15 x 4.7 x.36) Screw terminals (Pg 13.5 cable inlet)

More information

SensoLyt 700 SensoLyt 700 SW

SensoLyt 700 SensoLyt 700 SW Operating manual SensoLyt 700 SensoLyt 700 SW SensoLyt 700 SensoLyt 700 SW ph/orp armature with impedance converter and temperature sensor ba15307e04 12/2005 SensoLyt 700 (SW) Accuracy when going to press

More information

Paddle-wheel flow controller for On/Off control

Paddle-wheel flow controller for On/Off control Paddle-wheel flow controller for On/Off control Type 803 can be combined with... Indication, monitoring, transmitting and On/Off control in one device Programmable s (transistor or relay) Automatic-calibration:

More information

Design and application

Design and application Design and application The function of the SGM is based on the variable area float principle. In all cases where a dependable device is required for indicating instantaneous values and monitoring the flow

More information

Product information Hygienic Design GHMadapt / Accessories

Product information Hygienic Design GHMadapt / Accessories www.ghm-group.de Product information Hygienic Design GHMadapt / Accessories Characteristics Applications GHMadapt Welding sleeves without / with leakage holes Adapters Welding fittings CIP-/SIP-cleaning

More information

Flush-mounted pressure and level transmitters - KERAMESS KS series 100/101 -

Flush-mounted pressure and level transmitters - KERAMESS KS series 100/101 - FEATURES PRECISE MEASUREMENTS WITH AN ACCURACY OF ± 0.15% FS WITH DRY CERAMIC MEASURING CELL TURN-DOWN 10 EASY TO CLEAN AND HIGH PROTECTION CLASSES IP67 AND IP69K INTEGRATED ON-SITE DISPLAY OR EXTERNAL

More information

display on the wall or in a panel away from the inline sensor SE30 for easy meter reading.

display on the wall or in a panel away from the inline sensor SE30 for easy meter reading. Analogue Flow Rate Indicator, DN 15...; PN 1...16 Advantages / Benefits Reduced costs of ownership up to 6% Economic integration in pipe systems without any additional piping Shows flow rate with a large

More information

Temperature Sensor without thread

Temperature Sensor without thread 1 Product Information TFP-49, -169, -189, -06 Temperature Sensor without thread Application / Specified Usage Authorizations Installation in thin-walled pipes and vessels No product contacting of the sensor

More information

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0. DMK P Industrial Pressure Transmitter Pressure Ports With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 60 bar up to 0... 400 bar Output signals

More information

Conductivity meter. PLC Solenoid valve. Type Type On/Off Diaphragm valve. Valve islands

Conductivity meter. PLC Solenoid valve. Type Type On/Off Diaphragm valve. Valve islands Conductivity meter Configurable outputs: two transistor and single or dual analog 4... 20 ma Removable backlighted display Universal process connection Type can be combined with... Three cell constants

More information

Table of Contents 1. OVERVIEW OPERATION FUNCTION SPECIFICATIONS INSTRUMENT LAYOUT INSTALLATION...

Table of Contents 1. OVERVIEW OPERATION FUNCTION SPECIFICATIONS INSTRUMENT LAYOUT INSTALLATION... Table of Contents 1. OVERVIEW... 2 2. OPERATION FUNCTION... 2 3. SPECIFICATIONS... 3 4. INSTRUM LAYOUT... 4 4.1 OPERATION KEY...4 4.2 INDICATORS...4 5. INSTALLATION... 5 5.1. ENVIRONM CONDITIONS...5 5.2

More information

Signet ph/orp Electrodes

Signet ph/orp Electrodes Signet 2724-2726 ph/orp Electrodes Compatible with ALL Signet ph/orp Instruments Features Flat Glass Protected Bulb Patented reference design for exceptional performance * Mounts in Signet standard fittings

More information

Pressure transmitters for heavy duty applications MBS 8200 and MBS 8250

Pressure transmitters for heavy duty applications MBS 8200 and MBS 8250 Data sheet Pressure transmitters for heavy duty applications MBS 8200 and MBS 8250 MBS 8200 is a series of compact pressure transmitters developed to withstand the pressure pulsations and vibrations known

More information

SIGNET 2750 ph/orp Sensor ENGLISH

SIGNET 2750 ph/orp Sensor ENGLISH ENGLISH 3-2750.090 B-8/01 English SAFETY INSTRUCTIONS FOR IN-LINE ELECTRODE INSTALLATION 1. Do not remove from pressurized lines. 2. Do not exceed maximum temperature/pressure specifications. 3. Wear safety

More information

Pressure transmitter for general purpose Type MBS 1700 and MBS 1750

Pressure transmitter for general purpose Type MBS 1700 and MBS 1750 MAKING MODERN LIVING POSSIBLE Data sheet Pressure transmitter for general purpose Type MBS 1700 and MBS 1750 The compact pressure transmitters MBS 1700 and MBS 1750 are designed for use as a general purpose

More information

Plastic tube variable area flowmeter for liquids and gases

Plastic tube variable area flowmeter for liquids and gases Plastic tube variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or fusion welding connections)

More information

Signet ph/orp Electrodes

Signet ph/orp Electrodes Signet 2724-2726 ph/orp Electrodes Compatible with ALL Signet ph/orp Instruments Features Patented reference design for exceptional performance * Mounts in Signet standard fittings from DN15 to DN100 (½

More information

PRESSURE TRANSDUCERS. Specifications. Individual Specifications

PRESSURE TRANSDUCERS. Specifications. Individual Specifications 00 Series and 00 Heavy Duty Series Compact OEM Pressure Transmitters 0 50 psi to 0-0,000 psi ranges (0-.5 bar to 0-,00 bar) High Proof Pressures Broad Choice of Outputs RoHS Compliant For OEMs that need

More information

ph-kompaktelektrodensystem sensopac CPA 320

ph-kompaktelektrodensystem sensopac CPA 320 Technische Information TI 0C/0/de ph-kompaktelektrodensystem sensopac CPA 0 One of the two reference systems is specially protected so that only the second monitoring reference system is affected by penetration

More information

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 40

More information

BFS-10-O G1/4: BFS-10-O G1/2: BFS-10-O G1: Contact rating: BFS-10-O G1/4

BFS-10-O G1/4: BFS-10-O G1/2: BFS-10-O G1: Contact rating: BFS-10-O G1/4 Flow Switches Index: B / 923-1838 BFS-10-N / BFS-10-O for monitoring liquids, with or without optical display Features set point continuously adjustable rugged, low hysteresis, any mounting position, high

More information

Cleanfit CPA471. Technical Information. Compact retractable assembly for installation of ph, ORP electrodes in tanks or pipelines

Cleanfit CPA471. Technical Information. Compact retractable assembly for installation of ph, ORP electrodes in tanks or pipelines Technical Information Cleanfit CPA471 Compact retractable assembly for installation of ph, ORP electrodes in tanks or pipelines Application Chemical industry Wastewater treatment Plant design Tanks and

More information

Miniature resistance thermometer For sanitary applications Model TR21-A, with flange connection

Miniature resistance thermometer For sanitary applications Model TR21-A, with flange connection Electrical temperature measurement Miniature resistance thermometer For sanitary applications Model TR21-A, with flange connection WIKA data sheet TE 60.26 Applications Sanitary applications Food and beverage

More information

SCHMITT. product information. Kreiselpumpen. T Pump Series. submersible pumps. materials: PP or PVDF

SCHMITT. product information. Kreiselpumpen. T Pump Series. submersible pumps. materials: PP or PVDF SCHMITT Kreiselpumpen chemical resistant pumps for corrosive and highly pure media product information T Pump Series submersible pumps materials: PP or PVDF Description of the T Pump Series 2 - Submersible

More information

SATRON VTe pressure transmitter

SATRON VTe pressure transmitter SATRON VTe pressure transmitter belongs to the series V-transmitters which will have both analog and smart properties. SATRON VTe is used for 0-4 kpa...0-00 MPa ranges. The transmitter communicates in

More information

Immersion fittings. Brief description. Installation options Standard. Series Page 1/7. Data Sheet

Immersion fittings. Brief description. Installation options Standard. Series Page 1/7. Data Sheet JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net

More information

Signet DryLoc ph/orp Electrodes

Signet DryLoc ph/orp Electrodes Signet 2774-2777 DryLoc ph/orp Electrodes Features Patented DryLoc connector with gold plated contacts* Special design allows for installation at any angle, even inverted or horizontal Quick temperature

More information

Differential Pressure and Flow meters Accessories for the Media Series

Differential Pressure and Flow meters Accessories for the Media Series Differential Pressure and Flow meters Accessories for the Media Series 7 8 9 10 11 6 12 Media 5 Media 6 Media 05 1 5 2 4 Media 4 3 Selection and application These accessories upgrade the devices of the

More information

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm DMP P Industrial Pressure Transmitter Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Industrial

More information

Inline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 )

Inline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 ) EE771/EE772 Inline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 ) The inline flow meter EE771/EE772, based on the measurement principle of thermal mass flow, is ideally suited for the

More information

Signet DryLoc ph/orp Electrodes

Signet DryLoc ph/orp Electrodes Signet 2774-2777 DryLoc ph/orp Electrodes Features Patented DryLoc connector with gold plated contacts* Special design allows for installation at any angle, even inverted or horizontal Quick temperature

More information

OPTIFLUX 6000 Technical Datasheet

OPTIFLUX 6000 Technical Datasheet OPTIFLUX 6000 Technical Datasheet Electromagnetic flow sensor for hygienic and sanitary applications Robust stainless steel housing for hygienic and aseptic operation Fully suitable for CIP and SIP Typical

More information

Electromagnetic Flow Monitor magphant

Electromagnetic Flow Monitor magphant Technical Information TI 036D/06/en No. 50078457 Electromagnetic Flow Monitor magphant Monitoring and measurement Flow monitoring with selectable limit values (relay output) Flow measurement via 4...20

More information

Pressure transmitter COMPACT ECOnomic

Pressure transmitter COMPACT ECOnomic Pressure transmitter COMPACT ECOnomic for food/pharmaceutical/biotechnology, Type series CA1110 Features Digitale pressure transmitter Hygienic design according to EHEDG Case and wetted parts of stainless

More information

Pressure transmitters for heavy duty applications Type MBS 3250

Pressure transmitters for heavy duty applications Type MBS 3250 Pressure transmitters for heavy duty applications Type MBS 3250 Features Designed for use in harsh industrial environments For medium and ambient temperatures up to 125 C With integrated pulse-snubber.

More information

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05 Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing Ø

More information

Pressure transmitter for marine applications MBS 3100 and MBS 3150

Pressure transmitter for marine applications MBS 3100 and MBS 3150 Data sheet Pressure transmitter for marine applications MBS 3100 and MBS 3150 The compact ship approved pressure transmitters MBS 3100 and MBS 3150 are designed for use in almost all marine applications.

More information

better measurement Simply a question of

better measurement Simply a question of Simply a question of better measurement SCHMIDT Flow Sensor SS 2.415 and SS 2.515 The tried and tested measurement experts for the monitoring of laminar flows extremely precise and quickly installed Industrial

More information

JUMO tecline CR-4P Conductive 4-Electrode Conductivity Sensor

JUMO tecline CR-4P Conductive 4-Electrode Conductivity Sensor Page 1/6 JUMO tecine CR-4P Conductive 4-Electrode Conductivity Brief description The JUMO tecine CR-4P fills the gap between conductive conductivity measurement with two-electrode conductivity sensors,

More information

mass flowmeter for compressed air

mass flowmeter for compressed air mass flowmeter for compressed air VARIOMASS ECO pressure and temperature compensated easy and cost effective installation of the sensor no pressure loss caused by the sensor no moving parts, i.e. maintenance

More information

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm DMP P Industrial Pressure Transmitter Pressure Ports And Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO from 0... 00 mbar up

More information

SATRON VT Pressure Transmitter

SATRON VT Pressure Transmitter SATRON VT pressure transmitter belongs to the series V-transmitters. SATRON VT is used for 0-1.4 kpa...0-100 MPa ranges. It is a 2-wire transmitter with HART standard communication. In pressure measuring

More information

BATCHFLUX 5500 C Technical Datasheet

BATCHFLUX 5500 C Technical Datasheet BATCHFLUX 5500 C Technical Datasheet Electromagnetic flowmeter for volumetric filling machines High-stability zirconium oxide measuring tube Extreme long-term stability Most compact and lightweight design

More information