Diesel Pro FH235, FH236 and FH241 Series Filter/Separator/Warmer Installation Instructions

Size: px
Start display at page:

Download "Diesel Pro FH235, FH236 and FH241 Series Filter/Separator/Warmer Installation Instructions"

Transcription

1 A FH235 Cover Assembly Includes Vent Cap, Vent Cap O-Ring, Collar, Cover, Cover O-Ring, and Spring F E C D I Diesel Pro 235 Diesel Pro FH235, FH236 and FH241 Series Filter/Separator/Warmer Installation Instructions B Biodiesel O-Ring Pack Includes Vent Cap O-Ring and Cover O-Ring J F H K G Bottom Bowl Assembly Includes Bottom Bowl Seal, Bottom Bowl, Screws, Drain Valve O-Ring, and Drain Valve Manual Primer Pumps Parts List Part Description Part Number A FH235 Cover Assembly (includes Vent Cap, Vent Cap O-Ring, Collar, Cover, Cover O-Ring, and Spring) S B Biodiesel O-Ring Pack only required for >B5 fuel (includes Vent S Cap O-Ring and Cover O-Ring) C Filter Element See page 9 D Check Valve AssemblySP1413 E Diesel Pro FH235, Unheated See page 12 F Adapter - 7/8"-14 to M16 x S Adapter - 7/8"-14 to 3/8" NPT S G H Pre-Heater, 12 V, 195 W, WP Connector Pre-Heater, 24 V, 195 W, WP Connector Pre-Heater, 24 V, 195 W, Tyco Connector 120 VAC, 75 W Heater Bottom Bowl Assembly (includes Bottom Bowl Seal, Bottom Bowl, Screws, Drain Valve O-Ring, and Drain Valve) SP1312 SP1313 SP S S I Water-In-Fuel (WIF) Sensor S J Collar for Reduced Clearance Applications (optional) S K Collar Wrench, Metal S Not Shown WIF Wiring Harness WIF LED S S L Manual Primer Pump Plunger S M N Primer Pump Check Valve (M16) Primer Pump Check Valve (M18) Primer Pump Check Valve (3/8") Primer Pump Check Valve (7/8") Primer Pump Service Kit (M16) Primer Pump Service Kit (M18) Primer Pump Service Kit (3/8") S S SP S S S SP1632 O Primer Pump Service Kit S P Check Valve Assembly (M18) Check Valve Assembly (M16) Check Valve Assembly (7/8") Check Valve Assembly (3/8") SP72127 SP72128 SP72129 SP72130 Q Check Valve Assembly Kit SP1644 M O L N L P Q CAUTION: These instructions are intended for use by professional mechanics who are trained in the proper use of power and hand tools, using appropriate safety precautions (including eye protection).

2 page 2 Diesel Pro 236 Parts List Part Description Part Number A FH236 Cover Assembly includes Vent Cap, Vent Cap O-Ring, Collar, Cover, Cover O-Ring, and Spring) S A FH236 Cover Assembly Includes Vent Cap, Vent Cap O-Ring, Collar, Cover, Cover O-Ring, and Spring B Biodiesel O-Ring Pack Includes Vent Cap O-Ring and Cover O-Ring B Biodiesel O-Ring Pack only required for >B5 fuel (includes Vent S Cap O-Ring and Cover O-Ring) C Filter Element See page 9 D Check Valve Assembly SP1413 E Diesel Pro FH236, Unheated See page 12 F G Adapter - 7/8"-14 to M16 x 1.5 Adapter - 7/8"-14 to 3/8" NPT Pre-Heater, 12 V, 195 W, WP Connector Pre-Heater, 24 V, 195 W, WP Connector Pre-Heater, 24 V, 195 W, Tyco Connector 120 VAC, 75 W Heater S S SP1312 SP1313 SP S H Bottom Bowl Assembly (includes Bottom Bowl Seal, Bottom Bowl, Screws, Drain Valve O-Ring, and Drain Valve) S I Water-In-Fuel (WIF) Sensor S C K J Collar for Reduced Clearance Applications (optional) S K Collar Wrench, Metal S Not Shown WIF Wiring Harness S WIF LED S F E D I J F H G Bottom Bowl Assembly Includes Bottom Bowl Seal, Bottom Bowl, Screws, Drain Valve O-Ring, and Drain Valve L Manual Primer Pump Plunger S M N Primer Pump Check Valve (M16) Primer Pump Check Valve (M18) Primer Pump Check Valve (3/8") Primer Pump Check Valve (7/8") Manual Primer Pump (M16) Manual Primer Pump (M18) Manual Primer Pump (3/8") S S SP S S S SP1632 O Primer Pump Service Kit S P Check Valve Assembly (M18) Check Valve Assembly (M16) Check Valve Assembly (7/8") Check Valve Assembly (3/8") SP72127 SP72128 SP72129 SP72130 Q Check Valve Service Kit SP1644 Manual Primer Pumps M O L N L P Q

3 page 3 Diesel Pro 241 Parts List FH241 Cover Assembly Includes Vent Cap, Vent Cap O-Ring, Collar, Cover, Cover O-Ring, and Spring J R A M E C H F D B G I Part Description Part Number A FH241Cover Assembly includes Vent Cap, O-Ring, Collar, Cover, Cover O-Ring, S and Spring) B O-Ring Pack (Vent Cap and Collar) S C Filter Element See page 9 D Vent Cap Service Kit SP1053 E Filter Spring S F Reduced Clearance Collar S G Diesel Pro FH241, Unheated See page 13 H Adapter - 7/8" to M16 Adapter - 7/8" to M18 Adapter - 7/8" to 3/8" S SP S I Drain & Cap SP1647 J Pre-Heater, 24V, 195 W, Tyco Connector Pre-Heater, 24V, 195 W, WP Connector Over Night Heater, 120 V SP1314 SP S K Water-In-Fuel (WIF) Sensor S WIF Wiring Harness S WIF LED S Not ESOC/Drain Valve SP1645 Shown Drain Valve Service Kit SP1646 WIF Port Plug SP1125 L Manual Primer Pump Pump S M N Primer Pump Check Valve (M16) Primer Pump Check Valve (M18) Primer Pump Check Valve (3/8") Primer Pump Check Valve (7/8") Primer Pump Service Kit (M16) Primer Pump Service Kit (M18) Primer Pump Service Kit (3/8") S S SP S S S SP1632 O Primer Pump Service Kit S P Check Valve Assembly (M18) Check Valve Assembly (M16) Check Valve Assembly (7/8") Check Valve Assembly (3/8") SP72127 SP72128 SP72129 SP72130 Q Check Valve Service Kit SP1644 K R Collar Wrench, Metal S Manual Primer Pumps O L N L P Q

4 page 4 Introduction How It Works Fuel from the tank enters the Diesel Pro body (suction side of the fuel system). Large contaminants and free water are separated from the fuel and remain in the body. Fuel rises into the clear cover. Contaminants and emulsified water are captured by the filter media. Fuel level rises to maintain a fuel path through the clean filter media and with lowest restriction. Clean, water-free fuel exits the Diesel Pro and flows to the lift pump. Seeing Is Believing See when NOT to change the fuel filter. See the condition of the fuel. Seeing what collects on the filter media or what s happening inside the clear cover can help diagnose many fuel and mechanical conditions. Filter on Top configuration. Water and debris removed from the fuel falls to the lower chamber and stays away from the filter media resulting in longer filter life. Built-in protection when priming the fuel filter. Unfiltered fuel is kept on the dirty side of the filter media during priming ensuring only clean fuel reaches the engine. Patented media. The Best in Class StrataPore media removes 95% of free and emulsified water. This performance far exceeds that of cellulose media. Vent Cap Media Coalescent Layer Hydrophobic Layer Water Sump Dirty Side Drain Valve (ESOC Compatible) Fuel OUT Water Sump Clean Side Figure 1 - Seeing Is Believing 1. When new, the fuel level in the filter will be very low with minimal restriction. As the filter is used, contaminants collect on the filter from the bottom up. Fuel rises on the filter indicating remaining filter life. 2. Fuel level increases in clear cover. As contaminants collect on the filter, the fuel rises to a non-contaminated section of the filter, providing optimal filtration while maintaining lowest restriction. 3. Fuel level at filter wrap level. Even though the fuel level is now more than half of the filter element, the fuel is still flowing through clean media at minimal restriction levels. The filter still has significant life remaining. 4. The filter element is now completely covered by fuel. At this point, all of the media s surface area is utilized. Restriction is increasing and the filter element should be changed at the next scheduled maintenance interval. FH241 Series Advanced Water Separation Architecture The FH241 Series has a new water separation architecture providing higher water separation performance than the FH235 or FH236 series. The FS20081 cartridge has additional coalescing and hydrophobic layers that provide the performance required for T4F and EPA2017 midrange engines. The new water separation concept introduces two additional steps (coalescing on an additional layer, repelling on a hydrophobic layer), improving overall water separation performance.

5 page 5 Service Kit Installation This system must be installed between the fuel tank and the transfer fuel pump. If approved by the manufacturer, this system can be used as the only fuel filter in the fuel system by removing the existing filter and heads, or by removing the filters only and replacing them with special Diverter Caps (sold separately - see Table 1). Note: If the Diesel Pro is used as the primary filter and a secondary filter is required, secondary filter life may be extended. Diverter Cap Part Number Table 1 - Diverter Caps Required Filter Head Stud Size Required Filter Head Seal ID in (mm) Required Filter Head Seal OD in (mm) S 1" (62.865) (73.533) S 1" (81.915) (87.249) S M16 x (62.865) (73.533) S 3/4" x (62.865) (73.533) S 7/8" x (62.865) (73.533) WARNING: When diesel fuel is circulated through an operating engine, it can become very hot. To prevent personal injury: Scalding hazard! Do not allow heated liquid fuel to come in contact with eyes or unprotected skin. Always allow the engine and fuel to cool to ambient temperature before replacing the fuel filter or performing service operations which could result in the spillage of fuel from the fuel system. If this is not possible, protective clothing (face shield, insulated hat, gloves, apron) must be worn. Fire hazard! Heated diesel fuel can form combustible vapor mixtures in the area around the fuel source. To eliminate the potential for fire, keep open flames, sparks or other potential ignition sources away from the work area, and do not smoke during filter replacement or service operations which could result in the escape of diesel fuel or fuel vapors. Inhalation hazard! Always perform engine or vessel fuel system maintenance in a well ventilated area that is kept free of bystanders. The ignition key must be in the OFF position. Installing the Diesel Pro Service Kit 1. With the engine shut down and at ambient temperature, close the fuel shutoff valve (if equipped) and place a suitable container under the fuel filters. 2. Remove the primary fuel filter element assembly, sedimenter, and/or water separator. Drain the used element and dispose of it in an environmentally responsible manner, according to state and/or federal (EPA) or national recommendations. The fuel can be returned to the tank. 3. For a one-filter system, select the required secondary filter head diverter cap from those listed in Table 1. The required part number is determined by the size of the spin-on filter stud and the filter sealing surface diameter. Install the diverter cap on the secondary filter head as follows: a. Remove the secondary fuel filter element, drain and dispose of it in an environmentally responsible manner according to government regulations (i.e., state/province, federal, etc.). The fuel can be returned to the tank. b. Lightly lubricate the seal on the top of the diverter cap with clean engine oil. c. Thread the adapter onto the secondary filter stud and tighten by hand only. d. Install the "Do Not Remove" sticker on the diverter cap. 4. Mount the Diesel Pro in the desired location using 3/8" (9.5 mm) Grade 8 hardware. Keep the following points in mind: a. Mounting the Diesel Pro directly on the engine is NOT RECOMMENDED. b. Mount vertically with the cover and element pointing up. c. Make sure there is enough top and side clearance for the cover to be conveniently removed for filter replacement (1.5" (38.1 mm) minimum). d. Bolt spacing is 5.25" ( mm). CAUTION: The Diesel Pro MUST be installed so that the Filter Element is above the "FULL" level of the fuel tank. If mounted below full tank level, a shut off valve will be required at the inlet to allow filter changes without overflow of fuel.

6 page 6 5. Route the fuel supply line as follows (see Figure 2): a. Route the fuel supply line from the pickup on the fuel tank to the Diesel Pro inlet (labeled Fuel In ). b. Route the fuel outlet line from the Diesel Pro outlet (labeled Fuel Out ) to the inlet of the fuel pump. Diesel Pro b. Use 90 elbows only when necessary. c. If the fuel hoses are made up to length on the job, be sure that the inner liner of the fuel hose is not cut by the fitting, creating potential check valve effects. Also make sure hoses are clean and free of debris before installing. CAUTION: To avoid damaging the aluminum fuel processor body, do not overtighten fuel lines or fuel line fittings. 7. If an electrical heater is required, see page 6, Installing an Optional Electric Heater. Fuel Tank IN Lift Pump Injection Pump Figure 2 Diesel Pro Connections Note: The inlet and outlet fittings can be moved from side to side depending on the application. For example, in Figure 3 the FUEL IN is on the right and the FUEL OUT is on the right. Be sure to use only ONE INLET and ONE OUTLET port per installation. (Tighten adapter fittings and plugs to ft-lbs ( N m).) Installing a WIF (Water In Fuel) Probe 1. Remove the 1/2"-20 WIF plug from the bottom of the Diesel Pro. 2. Install the WIF Probe ( S) into the bottom of the Diesel Pro (see Figure 4). Torque to in-lbs ( N m). 3. Install the WIF wiring harness ( S) on the WIF Probe. The harness has the following connections: black ground lead with a 3/8" (9.53 mm) diameter loop end and a green WIF wire. WIF Probe HEATER Figure 3 Fuel Line Inlets and Outlets 6. To minimize restrictions, observe the following guidelines when plumbing the system. a. Keep the fuel line routing as smooth as possible with no low hanging loops which can trap water. Figure 4 WIF Probe Installation 4. Drill a 1/2" (12.70 mm) hole in the dash or control panel where the WIF LED ( S) is to be located. a. Installation must have 1.5" (38.10 mm) of clearance behind dash or control panel. b. Use caution not to damage nearby components when drilling. 5. Connect the black ground wire on WIF LED to a ground source. Attach additional black wire as needed.

7 page 7 6. Install WIF LED by pressing firmly into the drilled hole. 7. Connect the black ground lead with a 3/8" (9.53 mm) diameter loop end on the WIF wiring harness to ground source near the Diesel Pro (if applicable). 8. Connect green signal wire on WIF wiring harness to 4" ( mm) green signal wire on WIF LED. Use additional green wire as needed. 9. Locate a 12 VDC or 24 VDC power source. Run a red wire from power source to the red wire on WIF LED. Add a 1 A in-line fuse (not included). (See Figure 5). Figure 5 WIF Wiring Note: Use appropriate connectors to attach the wires. To test the WIF indicator, pour water into the body of the fuel processor until it covers the WIF probe. The WIF LED should illuminate. Installing an Optional Electric Heater All units come with pre-drilled ports to allow for heaters/thermostats. The electric heaters available for the Diesel Pro are 12 or 24 VDC Combo Thermo/Heaters and 120 VAC Heater. Electric heaters are optional and must be ordered separately (see Table 2). Table 2 Electric Heaters Part Number Description SP1312 Pre-Heater, 12 V, 195 W, WP Connector SP1313 Pre-Heater, 24 V, 195 W, WP Connector SP1314 Pre-Heater, 24 V, 195 W, Tyco Connector S 120 VAC, 75 W Heater S 120 VAC, 75 W Heater 1. If an Electric Heater is not already installed, remove the 7/8"-14 SAE (M16 x 1.5) o-ring heater plug from the Diesel Pro and install the Heater. Torque to ft-lbs ( N m). (See Figure 6.) PTC Heater Figure 6 - Heater Installation 2. Connect the Chassis harness to the Diesel Pro harness. 3. Attach the grounding eyelet to the chassis using a suitable 3/8" (9.5 mm) bolt. 4. Connect the Power Lead to the accessory side of the ignition switch. (Use of a 15 A fuse is recommended, but not included in the Diesel Pro kits. Use a relay if the ignition circuit will not handle a minimum of 15 A.) (See Figure 7.) Figure 7 Fuse and Relay Connections Installing Optional Priming Pumps The Fleetguard Manual Priming Pump must be installed on the suction side of the fuel system. CAUTION: Do not over tighten the fuel hoses to the fittings to avoid damage to the Priming Pump or filter housing.

8 L4758 Covered under one or more of the following U.S. patents: , , , RE37165 E, and foreign patents or others pending. page 8 Installing with a New Diesel Pro Produced Before August 30, 2010 or Any Diesel Pro Without a Bottom Bowl 1. Disconnect the fuel inlet line coming from the fuel tank to the Diesel Pro inlet. 2. Thread the T shaped plunger pump from kit # S (M18) or S (M16) into the Fuel Inlet Port of the Diesel Pro. 3. Attach the fuel line from the fuel tank to the inlet of the Primer Pump. 4. Tighten to ft-lb ( N m) of torque. 5. Remove the vent cap from the Diesel Pro. 6. Cycle the plunger of the Priming Pump until the Diesel Pro is full of fuel. 7. Hand tighten the vent cap. 8. Start the engine. When the lubrication system reaches normal operating pressure, increase the RPM for one minute. Slowly open the vent cap until the fuel level drops to one inch above the collar. 9. Check for fuel leaks. 10. Installation is complete. Diesel Pro Priming Pump ( S or S) 2. Thread the Check Valve ( S) from kit S into the inlet port of the Diesel Pro. 3. Reconnect the fuel line from the fuel tank to the Diesel Pro inlet with Check Valve in place. 4. Remove the plug from the free Fuel Inlet Port. 5. Thread the Plunger Assembly ( S) from kit S into the free Fuel Inlet Port. 6. Tighten to ft-lb ( N m) of torque. 7. Remove the vent cap from the Diesel Pro. 8. Cycle the plunger of the Priming Pump until the Diesel Pro is full of fuel. 9. Hand tighten the vent cap. 10. Start the engine. When the lubrication system reaches normal operating pressure, increase the Revolutions Per Minute (RPM) for one minute. Slowly open the vent cap until the fuel level drops to one inch above the collar. 11. Check for fuel leaks. 12. Installation is complete. Plunger Assembly ( S) Diesel Pro Check Valve ( S) Diesel Pro FH235 Series OUTLET INLET Fuel Line Note: Housings without the bottom bowl feature can use only the style priming pump shown here Fuel Tank Fuel Tank Figure 9 Installing the Priming Pump with a Diesel Pro Produced After August 30, 2010 Figure 8 Installing the Priming Pump with a Diesel Pro Produced Before August 30, 2010 Installing with a New Diesel Pro Produced After August 30, 2010 With a Bottom Bowl With the engine shut down and at ambient temperature, close the fuel shut-off valve (if equipped) and place a suitable container under the Diesel Pro and drain the fuel until empty. Filter Change Procedure 1. Remove the vent cap and open the drain valve to drain the fuel below the collar level. 2. Remove the collar using the Collar/Vent Cap Wrench ( S) then remove the clear cover. 1. Disconnect the fuel inlet line coming from the fuel tank to the Diesel Pro inlet.

9 page 9 Figure 10 Collar/Vent Cap Wrench 3. Remove the filter, cover, and vent cap seals. Dispose of the filter and the seals properly. 4. Using a clean rag, clean the cover, the collar, and threads on the Diesel Pro body. 5. Install a new filter, cover seal, and vent cap seal. 6. Reinstall the clear cover and collar. Hand tighten the collar. 7. Prime the unit by filling the clear cover with clean diesel fuel until it reaches the top of the filter. 8. Install the vent cap. Hand tighten only. 9. Start the engine and run for one minute. Slowly open the vent cap and allow the fuel to drop to about one inch (32 mm) above the collar. 10. Close the vent cap. Hand tighten only. It is normal for the fuel level to vary after the initial start-up and during engine operation. Filter performance is not affected. Table 3 Replacement Filters Diesel Pro 235 Part Number Description FS19730 StrataPore 7 micron FS19731 StrataPore 10 micron FS19785 StrataPore 25 micron Priming the System The Diesel Pro fuel processor must be filled with clean fuel before the filtering system will operate properly. Use the following procedure to prepare the Diesel Pro for service. 1. Check to make sure the drain valve at the base of the Diesel Pro is closed. 2. Remove the vent cap from the top of the clear cover. 3. Fill the Diesel Pro full of clean fuel. 4. Reinstall the vent cap and tighten by hand only. 5. Start the engine. 6. When the lubrication system reaches its normal operating pressure, increase engine RPM to high idle for one to two minutes. After the air is purged, loosen the vent cap until the fuel level lowers to just above the collar. Retighten the vent cap by hand only. 7. Hand tighten the collar again while the engine is running. CAUTION To avoid damage, do not use tools to tighten the collar. Note: The clear filter cover will not fill completely during engine operation. It will gradually fill over time and the fuel level will rise as the filter becomes plugged. Table 4 Replacement Filters Diesel Pro 236 Part Number Description FS19761 EleMax StrataPore 5 micron FS19624 EleMax StrataPore 7 micron FS19729 EleMax Cellulose 50 micron FS19728 EleMax StrataPore 25 micron FS19727 EleMax StrataPore 10 micron Table 5 Replacement Filters Diesel Pro 241 Part Number Description FS20081 EleMax StrataPore 10 micron

10 page 10 Suggested Preventive Maintenance Weekly Drain water 1. Turn off the engine and open the vent cap. 2. Place a suitable eight ounce plastic or metal container under the drain valve at the base of the Diesel Pro and open the valve. 3. Water will flow into the container. When the fuel begins to flow out the drain, close the drain valve. Drain the least amount of fuel possible. 4. Hand tighten the vent cap. 5. Start the engine. Raise the RPM for one minute to purge the air from the system. Every Filter Change Change the cover and vent cap o-rings (included with the filter service kit). Every 12 Months Check all electrical connections for corrosion. Check all fuel fittings for leaks. Extreme winter or salt corrosion environments may require lubrication of the top collar threads with Loctite anti-seize every 180 days. Servicing the Check Valve Assembly 1. Remove the vent cap and open the drain valve, drain the Diesel Pro completely. 2. Remove the collar, then remove the clear cover. 3. Remove the filter, cover and vent cap seals. Dispose of filters and seals properly. 4. Using a clean shop rag, clean the cover, the collar and threads on the Diesel Pro body. 5. Remove the check valve assembly (see Figure 11). 6. Clean and inspect the check valve body (Replace if the valve or the seat show any visible signs of damage) 7. Replace the check valve assembly into the Diesel Pro body (torque to ft-lbs). 8. Install a new filter, cover seal and vent cap seal. 9. Reinstall the clear cover and collar. Tighten the collar. 10. Prime the Diesel Pro by filling the clear cover with clean diesel fuel until it reaches the top of the filter. 11. Install the vent cap. 12. Start the engine and run for one minute. Slowly open the vent cap and allow the fuel level to drop to about one inch above the collar. 13. Close the vent cap. Hand tighten only. Troubleshooting Every Diesel Pro is factory tested for leaks and is marked with a traceable number to show that it has passed production testing. Most field issues associated with leaks are related to loose fittings. These leaks are easily eliminated by checking and torquing the fuel fittings in the area of the leak. Some fittings may also require the application of liquid Teflon sealer. Note: All suction side fuel filters experience bubbles. It is normal to see champagne size bubbles in the Diesel Pro at the Diesel Pro outlet or at the lift pump. Figure 11 Removing the Check Valve Assembly

11 page 11 Air Leak Air bubbles will be visible in the clear cover of the Diesel Pro if the leak originates from the fuel tank up to the fuel filter. The following is a quick test to isolate the air leak source. Bubbles Visible: 1. Remove the Diesel Pro inlet hose. 2. Install a jumper hose from the Diesel Pro to the fuel tank (through the fill cap) or to a container of fuel. 3. Start the engine. If this eliminates the air bubbles, the air source is at the fuel tank fittings or hose connections. 4. Tighten all fittings and connectors 5. Retest If air bubbles persist, the air source is on the Diesel Pro side of the system: 1. Tighten all fittings on the Diesel Pro. 2. Tighten the collar. 3. If the drain valve is suspected, install a plug in place of the drain valve (for test purposes only). If air bubbles continue to persist, test as follows: 1. Remove the Diesel Pro from the chassis. 2. Plug the fuel inlet port. Do not remove filter, cover/collar, vent cap, drain valve and/or check valve. If the Diesel Pro is equipped with a preheater, do not remove the preheater. 3. Apply 15 PSI of air pressure at the fuel outlet. Immerse the Diesel Pro in a tank of water and look for air bubbles. 4. Correct the source of the air leak and retest. Bubbles Not Visible Excessive Restriction If the fuel level is at the top of the filter, replace the fuel filter. The Diesel Pro will not cause excess system restriction if the fuel level is below the top of the filter. Loss of Prime When air is introduced into the fuel system, (for example, when draining water from the Diesel Pro or when replacing the fuel filter) a check valve is needed to keep the fuel system primed from the Diesel Pro back to the fuel tank. A check valve is standard with all Diesel Pros. To test for proper check valve operation: Remove the fuel inlet hose and open the vent cap. Fuel should not flow out of the Diesel Pro, although a slight seepage of fuel is normal. If fuel drains back to the fuel tank, remove the check valve assembly: 1. Disassemble the check valve assembly. Clean and inspect. 2. Replace the assembly if any cuts, grooves or nicks are evident in the valve or valve seat. 3. Reinstall the check valve assembly. 1. If there are symptoms of sucking air (indicated by engine loping/rough running performance/ power loss, etc.) and there are no bubbles in the clear cover, the air leak is either at the Diesel Pro outlet fitting, vent cap o-ring, the lift pump inlet connection, or the fuel hose/connections to the lift pump. 2. Inspect and tighten fittings as needed.

12 page 12 Ordering Information Diesel Pro 235 Housing Part Number Filter Element Heater WIF Cover Fuel Flow Fuel In & Fuel Out Port Size Priming Pump FH23500FS19730 N/A N/A Short In Right/Out Left 7/8"-14 No FH23501FS VDC, 195 W N/A Short In Right/Out Left 7/8"-14 No FH23502FS VDC, 195 W N/A Short In Right/Out Left 7/8"-14 No FH23503 M* FS19785 N/A Yes Short In Right/Out Left M16 No FH23504 M*FS VDC, 195 W Yes Short In Right/Out Left M16 No FH23506FS VDC, 195 W Yes Short In Right/Out Left 7/8"-14 No FH23508FS19731 N/A Yes Short In Right/Out Left 7/8"-14 No FH23509 M*FS19731 N/A Yes Short In Right/Out Left M16 No FH23510FS VDC, 195 W Yes Short In Right/Out Left 7/8"-14 No FH23515 M* FS19731 N/A (open) Yes Short In Right/Out Left (all open) FH23517 FS19730 N/A N/A Short In Right/Out Left 3/8" NPTF No FH23518 M* FS VDC, 195 W Yes Short In Right/Out Left M16 No M16 Yes * Metric units - not available in Europe Note: The Diesel Pro 235 can be upgraded to a Diesel Pro 236 by replacing the cover with Fleetguard part number S and the filter with Fleetguard part number FS For more information, contact Fleetguard Customer Assistance. Diesel Pro 236 Housing Part Number Filter Element Heater WIF Cover Fuel Flow Fuel In & Fuel Out Port Size Priming Pump FH23600FS19624 N/A N/A Tall In Right/Out Left 7/8"-14 SAE No FH23601FS VDC, 195 W N/A Tall In Right/Out Left 7/8"-14 SAE No FH23602FS VDC, 195 W N/A Tall In Right/Out Left 7/8"-14 SAE No FH23603FS19728 N/A Yes Tall In Right/Out Left 7/8"-14 SAE No FH23604 M*FS19728 N/A Yes Tall In Right/Out Left M16 No FH23605 M*FS VDC, 195 W Yes Tall In Right/Out Left M16 No FH23606 M*FS VDC, 195 W Yes Tall In Right/Out Left M16 No FH23607FS19727 N/A Yes Tall In Right/Out Left 7/8"-14 SAE No FH23608 M*FS19727 N/A Yes Tall In Right/Out Left M16 No FH23610FS19728 N/A N/A Tall In Right/Out Left 7/8"-14 SAE No FH23616 M**FS19624 N/A Yes Tall In Right/Out Left M16 No FH23617 M*FS19728 N/A (open) Yes Tall In Right/Out Left (all open) M16 Yes FH23618FS19727 N/A Yes Tall In Right/Out Left 7/8"-14 SAE Yes FH23621 M**FS VDC, 195 W Yes Tall In Right/Out Left M16 No FH23622 M**FS VDC, 195 W Yes Tall In Right/Out Left M16 No FH23623 M*FS19624 N/A Yes Tall In Right/Out Left M16 Yes FH23624 M*FS VDC, 195 W Yes Tall In Right/Out Left M16 No FH23625 M*FS VDC, 195 W Yes Tall In Right/Out Left M18 Yes FH23627FS19728 N/A Yes Tall In Right/Out Left 3/8" NPTF No FH23696*** FS19624 N/A Yes Tall In Right/Out Left M16 No * Metric units - available outside North America except Europe ** Metric units available in Europe *** Includes drain valve with hose barb connection

13 page 13 Ordering Information Diesel Pro 241 Housing Part Number Filter Element Heater WIF Cover Fuel Flow Fuel In & Fuel Out Port Size Priming Pump FH24100 FS20081 N/A Yes Tall In Left/Out Left M16 Yes FH24101 FS20081 N/A Yes Tall In Right/Out Left 7/8"-15 UNF Yes FH24102 FS20081 N/A Yes Tall In Right/Out Left 3/8" NPTF Yes FH24103 FS20081 N/A Yes Tall In Right/Out Left M16 Yes FH24104 FS VDC, 195 W Yes Tall In Left/Out Left M16 Yes FH24105 FS VDC, 195 W Yes Tall In Right/Out Left M16 Yes FH24106 FS VDC, 195 W Yes Tall In Right/Out Left M16 Yes FH24107 FS VDC, 195 W Yes Tall In Right/Out Left M18 Yes FH24108 FS VDC, 75 W Yes Tall In Right/Out Left 3/8" NPTF Yes FH24110 FS20081 N/A No Tall In Right/Out Left 7/8"-14 UNF No FH24111 FS20081 N/A No Tall In Right/Out Left M16 No FH24112 FS20081 N/A Yes Tall In Right/Out Left 7/8"-14 UNF No FH24113 FS20081 N/A Yes Tall In Right/Out Left M16 No FH24114 FS VDC, 195 W Yes Tall In Right/Out Left M16 No Specifications Specification Diesel Pro 235 Diesel Pro 236 Diesel Pro 241 Height Overall 10.75" (273.1 mm) 13.0" (330.2 mm) 13.36" (339.5 mm) Depth Overall 5.8" (147.3 mm) 5.8" (147.3 mm) 5.8" (147.3 mm) Width, max 6.22" (158.0 mm) 6.22" (158.0 mm) 6.22" (158.0 mm) Mount Bracket Centers or Rear Mount Centers 5.25" (133.4 mm) 3.0" (76.2 mm) 5.25" (133.4 mm) 3.0" (76.2 mm) 5.25" (133.4 mm) 3.0" (76.2 mm) Weight (Dry) 5 lbs (2.27 kg) 5 lbs (2.27 kg) 6-7 lbs ( kg) Fuel Connections (Inlet) 7/8"-14 (M16 x 1.5) 7/8"-14 (M16 x 1.5) 7/8"-14 (M16 x 1.5) Fuel Connection (Outlet) 7/8"-14 (M16 x 1.5) 7/8"-14 (M16 x 1.5) 7/8"-14 (M16 x 1.5) Fuel Capacity (w/o filter) 70.2 fl oz (1995 ml) 70.2 fl oz (1995 ml) 70.2 fl oz (1995 ml) Operation Fuel Flow Rate 60 gal/h (230 L/h) 90 gal/h (341 L/h) 60 gal/h (227 L/h) Recommended Applications Light and Medium Duty Engines Light and Medium Duty Engines Light and Medium Duty Engines Water Trap Capacity 15.2 fl oz (450 ml) 15.2 fl oz (450 ml) 15.2 fl oz (450 ml) Filter Service Clearance Min. 1.5" (38.1 mm) Min. 1.5" (38.1 mm) Min. 3.5" (88.9 mm) Mounting Bracket Cast in Head Cast in Head Cast in Head Electrical Heater Fuel Types Specifications subject to change without notice. 12 VDC, 195 W, 8.5 A ± 0.8 A 24 VDC, 195 W, 4.5 A ± 0.5 A 120 VAC, 75 W, 0.64 A ± 0.06 A 12 VDC, 195 W, 8.5 A ± 0.8 A 24 VDC, 195 W, 4.5 A ± 0.5 A 120 VAC, 75 W, 0.64 A ± 0.06 A Compatible for use with Diesel #1, Diesel #2, Kerosene, Biodiesel up to B20, and JP8 12 VDC, 195 W, 8.5 A ± 0.8 A 24 VDC, 195 W, 4.5 A ± 0.5 A 120 VAC, 75 W, 0.64 A ± 0.06 A

14 page 14 Dimensions Flow vs. Restriction Diesel Pro (281.9) 5.71 (145.0) 6.22 (158.0) 5.25 (133.4) All dimensions are in inches (millimeters) Service Height 1.5 (38.1).41 (10.3) (2X ) 2.92 (74.1) 1.54 (39.2) 2.28 (58.0) Differential Pressure (In-Hg) Fl ow (L/hr) FS Flow (gal/hr) Differential Pressure (kpa) Diesel Pro 236 Service Height 1.5 (38.1) 2.92 (74.1) 13.1 (332.7) 6.22 (158.0) 5.25 (133.4) 5.71 (145.0) All dimensions are in inches (millimeters).41 (10.3) (2X ) 1.54 (39.2) 2.28 (58.0) Differential Pressure (In-Hg) Fl ow (L/hr) FS Flow (gal/hr) Differential Pressure (kpa) Diesel Pro [158.0] 5.25 [133.4] Service Height 3.50 [88.9] 2.92 [74.1] 8.00 [203.2] MAX 2.21 (56.0) ø.53 [13.5] (2) holes 5.44 [138.2] [333.1] MAX 6.22 (158.0) 5.25 (133.4) All dimensions are in inches (millimeters) ø.41 (10.3) (2X) 1.34 [34.0] [407.2] MAX 1.71 [43.4] 2.28 [58.0] Differential Pressure (In-Hg) Fl ow (L/hr) FS Flow (gal/hr) Differential Pressure (kpa)

15 page 15 Revision Date Description 7 10/10/2017 Added FH241 Series 8 11/1/2017 SP1312 was S SP1313 was S SP1314 was S Heaters 195 W was 250 W and 150 W S, 250 W is obsolete 2 VDC, 195 W, 8.5 A ± 0.8 A was 12 VDC, 150 W, 12.5 A ± 1.3 A 24 VDC, 195 W, 4.5 A ± 0.5 A was 24 VDC, 150 W, 6.3 A ± 0.6 A Added Flow vs Restriction graphs Added FH23696 to Ordering Information 9 3/27/2018 Revised heater installation graphics, Fuel Type Biodiesel up to B20 was Biodiesel, Revised Diesel Pro 241 Dimension graphics, Added Priming Pump and Check Valve Service Kits to Parts Lists, Corrected conversion units on performance graphs 10 5/22/2018 FH23625 M thread size M18 was M16 For more information, visit cumminsfiltration.com LT36147 Rev Cummins Filtration Inc. Printed in the U.S.A.

Fuel Pro FH230 Series Filter/Separator/Warmer Installation Instructions

Fuel Pro FH230 Series Filter/Separator/Warmer Installation Instructions Fuel Pro FH230 Series Filter/Separator/Warmer Installation Instructions A B C Vent Cap and Assembly (part no. 3944440 S) Includes Vent Cap and Vent Cap Seal Parts List Part Description Part Number A Collar

More information

Fuel Pro Series Filter/Separator/Warmer Installation Instructions

Fuel Pro Series Filter/Separator/Warmer Installation Instructions Fuel Pro Series Filter/Separator/Warmer Installation Instructions Standard and Plus Series A B C D Vent Cap and Assembly (part no SP1053) Includes Vent Cap and Vent Cap Seal Part Description Part Number

More information

Industrial Pro FH234 Series Filter/Separator/Warmer Installation Instructions

Industrial Pro FH234 Series Filter/Separator/Warmer Installation Instructions Filter/Separator/Warmer Installation Instructions P M O A B C G U R H I OR N E X J D K L F VENT CAP FUEL PRO COLLAR Note: The Collar/Vent Cap Wrench is only supplied with the Single, Dual and Triple units

More information

Industrial Pro FH239 Series Filter/Separator/Warmer Installation Instructions

Industrial Pro FH239 Series Filter/Separator/Warmer Installation Instructions Industrial Pro FH239 Series Filter/Separator/Warmer Installation Instructions K L Cover Industrial Pro Single Short H I W A B D F P C E J Bottom Bowl G Vent Cap Filter Element (includes part C) I R S T

More information

Sea Pro FH240 Series Filter/Separator Installation Instructions

Sea Pro FH240 Series Filter/Separator Installation Instructions Sea Pro H240 Series ilter/separator nstallation nstructions Sea Pro Single Short A B C D E (ncludes parts B, D and G) Description Number A Top Nut Handle SP1288 B Nut Seal SP1287 C Service Cap SP1286 D

More information

Sea Pro FH240 Series Filter/Separator Installation Instructions

Sea Pro FH240 Series Filter/Separator Installation Instructions Sea Pro H240 Series ilter/separator Installation Instructions Sea Pro Single Short A B C D E Description Number A Top Nut Handle SP1288 B Nut Seal SP1287 C Service Cap SP1286 D Service Cap Seal SP1285

More information

TECHNICAL MANUAL FOR DTNA

TECHNICAL MANUAL FOR DTNA Diesel Pro 245 Technical Manual TABLE OF CONTENTS Applications, Models, and Options... 1 How it Works... 1 SEEING IS BELIEVING... 2 Dimensions and Specifications... 3 EE Important Safety Precautions...

More information

TABLE OF CONTENTS FOR UPDATED INFORMATION VISIT

TABLE OF CONTENTS FOR UPDATED INFORMATION VISIT TABLE OF CONTENTS Applications, Models, and Options.... 1 How it Works... 1 SEEING IS BELIEVING... 2 Dimensions and Specifications (Without Fluid Heat).... 3 Dimensions and Specifications (With Fluid Heat)...

More information

TECHNICAL MANUAL FOR DTNA

TECHNICAL MANUAL FOR DTNA TABLE OF CONTENTS Applications, Models, and Options... 1 How it Works... 1 SEEING IS BELIEVING... 2 Dimensions and Specifications... 3 EE Important Safety Precautions... 4 Installation Instructions...

More information

FH 230 SERIES FUEL PRO

FH 230 SERIES FUEL PRO FH 230 SERIES FUEL PRO D IESEL F UEL F ILTRATION S YSTEM All-In-One Fuel Filter, Fuel- Water Separator and Fuel Heater Seeing is Believing Eliminates unnecessary changes and maintenance Extended filter

More information

TABLE OF CONTENTS FOR UPDATED INFORMATION VISIT

TABLE OF CONTENTS FOR UPDATED INFORMATION VISIT TABLE OF CONTENTS Applications, Models, and Options.... 1 How it Works... 1 SEEING IS BELIEVING... 2 Dimensions and Specifications.... 3 EE Important Safety Precautions.... 4 Installation Instructions.................................................

More information

TABLE OF CONTENTS FOR UPDATED INFORMATION VISIT

TABLE OF CONTENTS FOR UPDATED INFORMATION VISIT B TABLE OF CONTENTS Applications, Models, and Options.... 1 How it Works... 1 SEEING IS BELIEVING... 2 Dimensions and Specifications.... 3 EE Important Safety Precautions.... 4 Installation Instructions.................................................

More information

Industrial Pro FH239 Series Filter/Separator/Warmer Installation Instructions

Industrial Pro FH239 Series Filter/Separator/Warmer Installation Instructions ndustrial Pro FH239 eries Filter/eparator/Warmer nstallation nstructions K Cover ndustrial Pro ingle hort H W F P C J ottom owl G Vent Cap Filter lement (includes part C) R V Q Collar escription Vent Cap

More information

DAVCO Fuel Processor Maintenance And Diagnostic Training

DAVCO Fuel Processor Maintenance And Diagnostic Training DAVCO Fuel Processor Maintenance And Diagnostic Training TRAINING SUMMARY This training program covers the operation, maintenance and diagnostic procedures for the DAVCO family of Fuel Processors. All

More information

EyeMax TECHNICAL MANUAL. Technology, LLC FOR UPDATED INFORMATION, VISIT TABLE OF CONTENTS

EyeMax TECHNICAL MANUAL. Technology, LLC FOR UPDATED INFORMATION, VISIT   TABLE OF CONTENTS REV 0 US and Foreign Patents: 6540909, 6841065, 7150824, 5507942, RE37165, 234242 L4814 Fuel Pro 482 Technical Manual. Technology, LLC TABLE OF CONTENTS How it Works............. 1 Typical Installation...........

More information

SHOP PRO FXP TECHNICAL MANUAL. FOR ADDITIONAL INFORMATION, VISIT TABLE OF CONTENTS

SHOP PRO FXP TECHNICAL MANUAL. FOR ADDITIONAL INFORMATION, VISIT   TABLE OF CONTENTS SHOP PRO FXP TABLE OF CONTENTS Applications and Features...1 Shop Pro FXP Components...2 EEImportant Safety Precautions.... 3 Set-up and Maintenance...4 Hoses and Adapters....5 Hose Connections for Priming...6

More information

DAVCO SHOP PRO FXP FOR MX ENGINES WITH REGULATOR TECHNICAL MANUAL

DAVCO SHOP PRO FXP FOR MX ENGINES WITH REGULATOR TECHNICAL MANUAL TABLE OF CONTENTS Applications and Features.... 1 Shop Pro Components... 2 Set-up and Maintenance... 3 Important Safety Precautions... 4 Hoses and Adapters... 5 Priming the PACCAR MX 11 EPA 2013 & MX 13

More information

All Racor filter materials and seals are compatible with ultra-low sulphur diesel (ULSD) fuel and B2 to B20 Biodiesel. See Racor bulletin 7679.

All Racor filter materials and seals are compatible with ultra-low sulphur diesel (ULSD) fuel and B2 to B20 Biodiesel. See Racor bulletin 7679. 000MA Water-in-fuel sensor and indicator. MA units have shielded see-thru bowls; MAM bowls are all-metal. UL-listed drain valve and water sensor probe options are available. Turbine Series Electric Primer

More information

Marine Fuel Filtration Marine 800 Series

Marine Fuel Filtration Marine 800 Series Racor recyclers offer large diesel engine operators both ease of maintenance and continuous engine operation. Continuous operations include filter changeouts and the draining of accumulated water from

More information

PENSKE SHOP PRO FXP TECHNICAL MANUAL. FOR ADDITIONAL INFORMATION, VISIT TABLE OF CONTENTS

PENSKE SHOP PRO FXP TECHNICAL MANUAL. FOR ADDITIONAL INFORMATION, VISIT   TABLE OF CONTENTS PENSKE SHOP PRO FXP TABLE OF CONTENTS Applications and Features...1 Shop Pro FXP Components...2 EEImportant Safety Precautions.... 3 Set-up and Maintenance...4 Hoses and Adapters....5 Hose Connections

More information

Winslow Liquid Fuel Filters Standard Design Type 2 Service Instructions

Winslow Liquid Fuel Filters Standard Design Type 2 Service Instructions Winslow Liquid uel ilters Standard Design Type 2 Service Instructions Parts List Part Description Part C D G O-Ring Housing Plugs ilter lements Component Kit T-olt Kit See Ordering Information on Page

More information

SHOP PRO FXP 95 TECHNICAL MANUAL

SHOP PRO FXP 95 TECHNICAL MANUAL SHOP PRO FXP 95 TABLE OF CONTENTS Applications and Features... 1 Shop Pro FXP 95 Components... 2 Important Safety Precautions.... 3 Set-up and Maintenance... 4 Prevent Fuel Spillage... 5 Hoses and Adapters...

More information

SHOP PRO ST TECHNICAL MANUAL. FOR ADDITIONAL INFORMATION, VISIT TABLE OF CONTENTS

SHOP PRO ST TECHNICAL MANUAL. FOR ADDITIONAL INFORMATION, VISIT   TABLE OF CONTENTS SHOP PRO ST TABLE OF CONTENTS Applications and Features...1 Shop Pro ST Components...2 EEImportant Safety Precautions.... 3 Set-up and Maintenance...4 Hoses and Adapters....5 Hose Connections for Priming...6

More information

Marine Turbine Series

Marine Turbine Series 1000MA Water-in-fuel sensor and indicator. All Racor filter materials and seals are compatible with ultra-low sulphur diesel (ULSD) fuel and B2 to B20 Biodiesel. See Racor bulletin 7679. The complete Primer

More information

Marine Fuel Filtration. Marine Turbine Series. Stage One: Separation. Stage Two: Coalescing. Stage Three: Filtration. And more

Marine Fuel Filtration. Marine Turbine Series. Stage One: Separation. Stage Two: Coalescing. Stage Three: Filtration. And more filter assemblies are designed to be installed on the vacuum side of the fuel transfer pump for best efficiency and protect precision engine components from dirt, rust, algae, asphaltines, varnishes, and

More information

PENSKE SHOP PRO ST WITH 50/80 PSI REGULATOR TECHNICAL MANUAL. FOR ADDITIONAL INFORMATION, VISIT TABLE OF CONTENTS

PENSKE SHOP PRO ST WITH 50/80 PSI REGULATOR TECHNICAL MANUAL. FOR ADDITIONAL INFORMATION, VISIT   TABLE OF CONTENTS TABLE OF CONTENTS Applications and Features...1 Shop Pro ST Components...2 EEImportant Safety Precautions.... 3 Set-up and Maintenance...4 Hoses and Adapters....5 Hose Connections for Removing Fuel.............................

More information

QuickServe Online ( ) ISB6.7 CM2350 B101 Service Manual

QuickServe Online ( ) ISB6.7 CM2350 B101 Service Manual Page 1 of 31 (/qs3/pubsys2/xml/en/manual/2883567/2883567-titlepage.html) Select Service Tools Recommended Cummins Service Tools 0.043 inch orificed diagnostic fuel line, Part Number 3164621 Diagnostic

More information

Product Features: Removes 99% of free water. Available with 2, 10, or 30 micron Aquabloc II media

Product Features: Removes 99% of free water. Available with 2, 10, or 30 micron Aquabloc II media 120A and 120B Series Fuel Filter/Water Separators Instruction Part Number 10219 Rev B Overview: 120A and 120B fuel filter/water separators are designed to be installed on the suction side of the fuel system

More information

Flow Max. by Duraself. Flow Max by Duraself. Fluid Pump. Installation and Owner s Manual (For Aftermarket Applications)

Flow Max. by Duraself. Flow Max by Duraself. Fluid Pump. Installation and Owner s Manual (For Aftermarket Applications) Flow Max Installation and Owner s Manual (For Aftermarket Applications) Table of Contents Introduction... 2 Parts List... 2 Resources Required... 3 Installation... 3 General Installation Instructions...

More information

Racor 75500FGX Turbine Series fuel

Racor 75500FGX Turbine Series fuel Installation Instructions 75500FGX Fuel Filter Racor 75500FGX Turbine Series fuel filter/water separator assemblies are designed to be installed on the vacuum side of the fuel transfer pump for best efficiency

More information

400 Series Spin-on Fuel Filter/Water Separators

400 Series Spin-on Fuel Filter/Water Separators 00 Series Spin-on Fuel Filter/Water Separators Instruction Part Number 09 Rev G 00 Series fuel filter/water separators are designed to handle today s tough fuel filtration problems and can be used anywhere

More information

MASTER COALESCER JR & PORTABLE MASTER COALESCER JR AIR PUMP MODEL INSTALLATION MANUAL

MASTER COALESCER JR & PORTABLE MASTER COALESCER JR AIR PUMP MODEL INSTALLATION MANUAL MASTER COALESCER JR & PORTABLE MASTER COALESCER JR AIR PUMP MODEL INSTALLATION MANUAL INSTALLATION: CHOOSING THE LOCATION: Locate the coalescer as near to the intended point of use as possible. Avoid high

More information

Flow Max Fluid Pump. by Duraself OEM INSTALLATION MANUAL

Flow Max Fluid Pump. by Duraself OEM INSTALLATION MANUAL Flow Max Fluid Pump by Duraself OEM INSTALLATION MANUAL TABLE OF CONTENTS System and Safety Information 2 Resources Required 3 Installation 3 General Installation Instructions 3 Mounting Instructions 3

More information

Rev: Flow Max 115V AC Fluid Pump

Rev: Flow Max 115V AC Fluid Pump Flow Max 115V AC Fluid Pump by Duraself Installation and Owner s Manual (For Aftermarket Applications) Table of Contents Introduction... 2 Parts List... 2 Resources Required... 3 Installation... 3 General

More information

Operating and Installation Instructions

Operating and Installation Instructions Model Number 40401-c (-sp) Electronic Fuel Pump Operating and Installation Instructions This Product is Patent Pending. Application available upon request CAUTION! This product is to be installed only

More information

AEROMOTIVE Part # & Stealth Fuel Tank Sump INSTALLATION INSTRUCTIONS

AEROMOTIVE Part # & Stealth Fuel Tank Sump INSTALLATION INSTRUCTIONS AEROMOTIVE Part # 18651 & 18652 Stealth Fuel Tank Sump INSTALLATION INSTRUCTIONS CAUTION: Installation of this product requires detailed knowledge of automotive systems and repair procedures. We recommend

More information

FUEL KITS P/N & 526-4

FUEL KITS P/N & 526-4 FUEL KITS P/N 526-3 & 526-4 NOTE: These instructions must be read and fully understood before beginning installation. If this manual is not fully understood, installation should not be attempted. Failure

More information

Installation Notes for Ford Excursion 7.3L

Installation Notes for Ford Excursion 7.3L The following document is used in conjunction with the puradyn Bypass Oil Filtration System Installation Manual (PFT 8) that is included in the unit box, and as such, should be considered a supplemental

More information

DF-200 w/adjustable Regulator INSTALLATION MANUAL. CUMMINS POWERED DODGE TRUCKS Model Year 1994 THROUGH 1998

DF-200 w/adjustable Regulator INSTALLATION MANUAL. CUMMINS POWERED DODGE TRUCKS Model Year 1994 THROUGH 1998 #12 DF-200 w/adjustable Regulator INSTALLATION MANUAL CUMMINS POWERED DODGE TRUCKS Model Year 1994 THROUGH 1998 High Performance Demand Flow Fuel System With New Quick Connect Components PLEASE READ THIS

More information

INSTALLATION INSTRUCTIONS FOR THE TRUCK MOUNTED VIPER ADDITIVE INJECTION SYSTEM GTP-8776C

INSTALLATION INSTRUCTIONS FOR THE TRUCK MOUNTED VIPER ADDITIVE INJECTION SYSTEM GTP-8776C INSTALLATION INSTRUCTIONS FOR THE TRUCK MOUNTED VIPER ADDITIVE INJECTION SYSTEM GTP-8776C This additive injection system was designed to be used with five gallon jug of additive. The system is supplied

More information

DISPLACEMENT PUMP INSTRUCTIONS-PARTS LIST Rev. K. Model , Series A Model , Series B Model , Series A

DISPLACEMENT PUMP INSTRUCTIONS-PARTS LIST Rev. K. Model , Series A Model , Series B Model , Series A INSTRUCTIONS-PARTS LIST INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. DISPLACEMENT PUMP 308190 Rev. K 3000 psi (210 bar) MAXIMUM WORKING PRESSURE Model

More information

Crankcase Ventilation Manager (CVM) Installation Instructions

Crankcase Ventilation Manager (CVM) Installation Instructions Crankcase Ventilation Manager (CVM) Installation Instructions CVM280 CVM424 Parts List E D C B A A B C D E Part Description No. Included A Shell 1 B Collar 1 C *O-Ring 1 D *Element 1 E Head 1 Part Number

More information

AEROMOTIVE Part # HP Hot Rod EFI Kit INSTALLATION INSTRUCTIONS

AEROMOTIVE Part # HP Hot Rod EFI Kit INSTALLATION INSTRUCTIONS AEROMOTIVE Part # 17150 700HP Hot Rod EFI Kit INSTALLATION INSTRUCTIONS CAUTION: Installation of this product requires detailed knowledge of automotive systems and repair procedures. We recommend that

More information

FleetguardFIT Installation Instructions

FleetguardFIT Installation Instructions RM FleetguardFIT Installation Instructions for QSK60 and QSK78 Engines Description Number 1 Filter Monitor System (FMS) Module SM15870 1 2 Sensor reakout Harness SP72085 3 Data Link Harness SP72084 (for

More information

2 Fluid Level Management

2 Fluid Level Management 2 Fluid Level Management Introduction.................................... 2-3 REN Oil Level Regulator........................ 2-5 REN Slow Flow Meter.......................... 2-9 Slow Flow Meter Remote

More information

Duramax Lift Pump Kit 9-11 PSI Installation Instructions P/N# D

Duramax Lift Pump Kit 9-11 PSI Installation Instructions P/N# D 2001-10 Duramax Lift Pump Kit 9-11 PSI Installation Instructions P/N# 1050320D PLEASE READ ALL INSTRUCTIONS CAREULLY BEORE INSTALLATION Kit Contents 1500365-P2 1500330-D lowmax Lift Pump V3 lowmax Wiring

More information

AIR CLEANER GENERAL REMOVAL. 1CAUTION Do not run engine without filter element in place. Debris could be drawn into the engine causing damage.

AIR CLEANER GENERAL REMOVAL. 1CAUTION Do not run engine without filter element in place. Debris could be drawn into the engine causing damage. AIR CLEANER GENERAL The air cleaner prevents foreign material from entering the carburetor and engine by trapping airborne dust and dirt in the filter element. Service air cleaner filter element every

More information

Power Train. Chapter 5

Power Train. Chapter 5 Chapter Power Train Spefications................................................................. -3 Test Spefications........................................................ -3 Repair Spefications.......................................................

More information

120RMAM Marine Series Fuel Filter/Water Separators

120RMAM Marine Series Fuel Filter/Water Separators 10RMAM Marine Series Fuel Filter/Water Separators Instruction Part Number 1945 Rev A Overview The 10RMAM fuel filter/water separator features 1/4-18 NPTF inlet and outlet fuel ports and a unitized mounting

More information

75500MAX Series and 75500MAXM Series

75500MAX Series and 75500MAXM Series 75500MAX Series and 75500MAXM Series Marine Fuel Filter/Water Separators Instruction Part Number 15349 Rev E Racor Turbine Series fuel filter/ water separators protect the precision components of your

More information

General The Racor Marine Diesel Spin--on Series feature a variety of compact sizes to fit most installations and cramped engine compartments.

General The Racor Marine Diesel Spin--on Series feature a variety of compact sizes to fit most installations and cramped engine compartments. Selection Selection Information General The Racor Marine Diesel Spin--on Series feature a variety of compact sizes to fit most installations and cramped engine compartments. Mounting Heads: These units

More information

660R-RAC Series. Gasoline Fuel Filter/Water Separators. Overview: Contact Information: Product Features: Instruction Part Number Rev F

660R-RAC Series. Gasoline Fuel Filter/Water Separators. Overview: Contact Information: Product Features: Instruction Part Number Rev F 660R-RAC Series Gasoline Fuel Filter/Water Separators Instruction Part Number 1385 Rev F Overview: Don t be caught in the water without one of these Racor gasoline spin on series filters. These filters

More information

320R-RAC Series. Gasoline Fuel Filter/Water Separators. Overview: Contact Information: Product Features: Instruction Part Number Rev.

320R-RAC Series. Gasoline Fuel Filter/Water Separators. Overview: Contact Information: Product Features: Instruction Part Number Rev. 30R-RAC Series Gasoline Fuel Filter/Water Separators Instruction Part Number 37 Rev. D Overview: Racor 30R-RAC series filters are designed for high-performance applications, which means your engine will

More information

Installation Notes for Asplundh Chipper Model- 1003ASP- (EPS) Kubota 3.3 L KIT DOC

Installation Notes for Asplundh Chipper Model- 1003ASP- (EPS) Kubota 3.3 L KIT DOC Note: Even though a banjo fitting has been provided, some engines have been known to have different size drain plugs, requiring a different size banjo fitting. If the banjo fitting provided does not match

More information

Page 1 of 19. Part# /10/2006

Page 1 of 19. Part# /10/2006 Part# 1002733-01 10/10/2006 This manual contains important information concerning the installation and operation of the gun washers listed above. Read manual thoroughly and keep for future reference INSTRUCTIONS

More information

Moduflow. ILP and RFP Low Pressure Filters. Series

Moduflow. ILP and RFP Low Pressure Filters. Series Moduflow ILP and RFP Low Pressure Filters Series 27 Applications for Moduflow Filters Power Unit Fabrication Off-line Filter Loops Mobile Equipment The Moduflow filter is widely considered the most versatile

More information

FORD POWERSTROKE 6.0L DIESEL ENGINE

FORD POWERSTROKE 6.0L DIESEL ENGINE #8 INSTALLATION MANUAL MODEL FP-100 & FP-150 With New Quick Connect Components! 2003-2007 FORD POWERSTROKE 6.0L DIESEL ENGINE Performance Fuel System Parts PLEASE READ THESE INSTRUCTIONS THOROUGHLY BEFORE

More information

Fleetguard Open Crankcase Ventilation (OCV) Kit Installation Instructions

Fleetguard Open Crankcase Ventilation (OCV) Kit Installation Instructions Fleetguard Open Crankcase Ventilation (OCV) Kit nstallation nstructions A B G C nstallation nstructions for: CV50108 60-90 P Applications CV50109 91-120 P Applications CV50110 121-160 P Applications CV50111

More information

SHOP PRO FXP 95 UPGRADE KIT (REGULATED)

SHOP PRO FXP 95 UPGRADE KIT (REGULATED) 1. Make sure the Shop Pro FXP is disconnected from the 120VAC power source. 4. Loosen the five ¼" headed bolts slightly until the motor cover slides to the left and remove the cover. 2. Remove the vent

More information

FUEL KITS P/N & 526-2

FUEL KITS P/N & 526-2 FUEL KITS P/N 526-1 & 526-2 NOTE: These instructions must be read and fully understood before beginning installation. If this manual is not fully understood, installation should not be attempted. Failure

More information

Page 1 of 12. Part# /30/2016

Page 1 of 12. Part# /30/2016 Part# 1007480-02 9/30/2016 This manual contains important information concerning the installation and operation of the gun washers listed above. Read manual thoroughly and keep for future reference. INSTRUCTIONS

More information

7649A FUEL INJECTOR CLEANING SPECIALTY TOOLS USER MANUAL & REPLACEMENT PARTS LIST

7649A FUEL INJECTOR CLEANING SPECIALTY TOOLS USER MANUAL & REPLACEMENT PARTS LIST 7649A FUEL INJECTOR CLEANING SPECIALTY TOOLS USER MANUAL & REPLACEMENT PARTS LIST Safety Precautions WARNING: The following safety precautions must be carefully observed to reduce the risk of fire and

More information

B-026INT October 6, 1999 FUEL FILTER BRACKET RETROFIT (JAPAN ONLY) GENERAL RETURN THIS TO: INITIAL HERE TECHNICIAN NO.

B-026INT October 6, 1999 FUEL FILTER BRACKET RETROFIT (JAPAN ONLY) GENERAL RETURN THIS TO: INITIAL HERE TECHNICIAN NO. 5 SERVICE BULLETIN B-026INT October 6, 1999 FUEL FILTER BRACKET RETROFIT (JAPAN ONLY) GENERAL It has come to the attention of Buell Distribution Corporation that a certain number of 2000 Model X1 and S3/T

More information

Section 10 Chapter 17

Section 10 Chapter 17 Section 10 Chapter 17 24 Valve, 8.3 Liter Engine Air Intake System Note: All coding used in the 8.3 Liter and 9 Liter engine manuals are Cummins engine codes. These engine codes have no meaning to New

More information

A Complete Guide to Spiratec Rotor (CS41018/CS41011) & Remote Centrifuge Product Benefits & Installation Instructions

A Complete Guide to Spiratec Rotor (CS41018/CS41011) & Remote Centrifuge Product Benefits & Installation Instructions A Complete Guide to Spiratec Rotor (CS41018/CS41011) & Remote Centrifuge Product Benefits & Installation Instructions This d describes: Product benefits Remote centrifuge housing specifications How to

More information

INSTALLATION MANUAL APPLICATION: T D07 220G 16-18psi) T D07 260G 16-18psi) Cummins 5.9L /6.7L 24Valve Standard Pickup Truck

INSTALLATION MANUAL APPLICATION: T D07 220G 16-18psi) T D07 260G 16-18psi) Cummins 5.9L /6.7L 24Valve Standard Pickup Truck INSTALLATION MANUAL APPLICATION: T D07 220G (220GPH @ 16-18psi) T D07 260G (260GPH @ 16-18psi) Cummins 5.9L /6.7L 24Valve Standard Pickup Truck 2005-2016 1998.5-2004 *with In-tank Lift Pump* **Note: Cab

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS 2807 INSTALLATION INSTRUCTIONS SECTION - AIR SPRING SECTION 2 - AIR ACCESSORY -6 ! IMPORTANT PLEASE DON T HURT YOURSELF, YOUR KIT OR YOUR VEHICLE. TAKE A MINUTE TO READ THIS IMPORTANT INFORMATION. This

More information

12CS/50CS Series. Coreless Spin-on Filters

12CS/50CS Series. Coreless Spin-on Filters 12CS/5CS Series Coreless Spin-on Filters 65 12CS/5CS Series Applications Together we can Preserve the environment. Minimize waste and promote energy efficiency. Achieve worldwide filtration solutions.

More information

Oregon Fuel Injection

Oregon Fuel Injection Cummins PT Fuel Pump Diagnostic No Start, with no smoke 1. This could be caused by the fuel pump not turning or a seized gear pump. Remove the fuel supply hose and the fuel inlet fitting from the gear

More information

Low Profile J Series Power Unit with Vane Pump

Low Profile J Series Power Unit with Vane Pump Low Profile J Series Power Unit with Vane Pump READ ALL INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING

More information

FUEL PRESSURE LEAK DOWN

FUEL PRESSURE LEAK DOWN 2010 Dodge or Ram Truck RAM 1500 Truck 2WD V8-5.7L Vehicle > Powertrain Management > Fuel Delivery and Air Induction > Fuel Pump > Fuel Pressure > Testing and Inspection > Component Tests and General Diagnostics

More information

Installation Instructions

Installation Instructions Installation Instructions for 15912 to 15916 Electric Fuel Pumps & Fuel Pressure Regulators Installation Instructions WARNING! These instructions must be read and fully understood before beginning the

More information

This information covers checking the fuel system of the Volvo D16F engine.

This information covers checking the fuel system of the Volvo D16F engine. Volvo Trucks North America Greensboro, NC USA Fuel System, Troubleshooting DService Bulletin Trucks Date Group No. Page 11.2006 230 251 1(7) Fuel System Troubleshooting D16F This information covers checking

More information

12AT/50AT Series Spin-On Filters

12AT/50AT Series Spin-On Filters 1 Applications for Mobile Equipment Hydrostatic Drives Industrial Power Units Reservoir Breathers Often, economic conditions dictate what type of filter is used on a piece of equipment. When costs are

More information

Airless Spray Gun INSTRUCTIONS DP psi (345 bar) Maximum Working Pressure

Airless Spray Gun INSTRUCTIONS DP psi (345 bar) Maximum Working Pressure INSTRUCTIONS DP-6376 Airless Spray Gun 5000 psi (345 bar) Maximum Working Pressure INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. Table of Contents Warnings......................................

More information

Low Pressure Filters. Low Pressure Filters LOW PRESSURE FILTERS

Low Pressure Filters. Low Pressure Filters LOW PRESSURE FILTERS Low Pressure Filters Low pressure filters are the most common type of filter found in hydraulic circuits used most often in return line applications. Low Pressure Filters Donaldson low pressure filters

More information

PLEASE READ THESE INSTRUCTIONS THOROUGHLY BEFORE BEGINNING INSTALLATION. Part No. A7SOCA700

PLEASE READ THESE INSTRUCTIONS THOROUGHLY BEFORE BEGINNING INSTALLATION. Part No. A7SOCA700 SPIN-ON High Pressure Fuel Air Separator INSTALLATION MANUAL For Engines with 136-5017 Filter Head PLEASE READ THESE INSTRUCTIONS THOROUGHLY BEFORE BEGINNING INSTALLATION Part No. A7SOCA700 Revised 8/17/17

More information

Eclipse GEN 2.0 CAFSystem, Model 150-ESECL as used with TC20 Series PTO Installation Instructions

Eclipse GEN 2.0 CAFSystem, Model 150-ESECL as used with TC20 Series PTO Installation Instructions Eclipse GEN 2.0 CAFSystem, Model 150-ESECL as used with TC20 Series PTO Installation Instructions Read Read through the the safety installation information instructions overhaul carefully instructions

More information

Authorized Field Change

Authorized Field Change Authorized Field Change AFC 08907R Date: June, 2008 Subject File: ENGINE Subject: Fuel Pressure Regulator and Fuel Pressure Switch on VT 275 Engines in Workhorse Commercial Chassis Model: Workhorse Start

More information

ENGINE COOLING GROUP CONTENTS RADIATOR GENERAL DESCRIPTION SPECIAL TOOLS THERMOSTAT

ENGINE COOLING GROUP CONTENTS RADIATOR GENERAL DESCRIPTION SPECIAL TOOLS THERMOSTAT 14-1 GROUP 14 CONTENTS GENERAL DESCRIPTION 14-2 SPECIAL TOOLS 14-3 DIAGNOSIS 14-3 INTRODUCTION 14-3 TROUBLESHOOTING STRATEGY 14-3 SYMPTOM CHART 14-4 SYMPTOM PROCEDURES 14-4 ON-VEHICLE SERVICE 14-17 ENGINE

More information

Not required for most applications. Not required for most applications. High pressure ( provided) High pressure ( provided)

Not required for most applications. Not required for most applications. High pressure ( provided) High pressure ( provided) ELECTRIC FUEL PUMPS P/N 12-801-1, 712-801-1, 12-802-1, 12-802-2, 712-802-1, 12-812, 12-815-1, & 712-815-1 FUEL PRESSURE REGULATORS P/N 12-500, 12-501, 12-803, 12-803BP, 12-804, & 15812NOS Installation

More information

AEROMOTIVE Part # Generic EFI Fuel System INSTALLATION INSTRUCTIONS

AEROMOTIVE Part # Generic EFI Fuel System INSTALLATION INSTRUCTIONS AEROMOTIVE Part # 17150 Generic EFI Fuel System INSTALLATION INSTRUCTIONS CAUTION: Installation of this product requires detailed knowledge of automotive systems and repair procedures. We recommend that

More information

IMPORTANT INFORMATION

IMPORTANT INFORMATION Table of Contents IMPORTANT INFORMATION Section 1B - Maintenance MAINTENANCE 1 B Specifications................................ 1B-1 Special Tools................................ 1B-2 Quicksilver Lubricant/Sealant..................

More information

18SP653 EPA04 and EPA98 MBE 4000 High Pressure Fuel Line and Transfer Tube Installation

18SP653 EPA04 and EPA98 MBE 4000 High Pressure Fuel Line and Transfer Tube Installation 18SP653 EPA04 and EPA98 MBE 4000 High Pressure Fuel Line and Transfer Tube Installation KIT DESCRIPTION A service kit (P/N: A4600700135) is now available to install EPA07 high pressure fuel injector lines

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS 28 INSTALLATION INSTRUCTIONS SECTION - AIR SPRING SECTION 2 - AIR ACCESSORY 2-5 ! IMPORTANT PLEASE DON T HURT YOURSELF, YOUR KIT OR YOUR VEHICLE. TAKE A MINUTE TO READ THIS IMPORTANT INFORMATION. This

More information

Fueltec Models 950AW & 955SS Mobile Fuel Tank Cleaning Systems

Fueltec Models 950AW & 955SS Mobile Fuel Tank Cleaning Systems Fueltec Models 950AW & 955SS Mobile Fuel Tank Cleaning Systems Operation Manual Fueltec Systems LLC 828-212-1141 www.fueltecsystems.com FEATURES Stainless steel filter housings to resist the acids found

More information

Fuel System Diagnosis

Fuel System Diagnosis Page 1 of 6 2004 Chevrolet Chevy K Silverado - 4WD Sierra, Silverado (VIN C/K) Service Manual Engine Engine Controls - 6.6L (LLY) Diagnostic Information and Procedures Document ID: 1460257 Fuel System

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS DUAL EXTERNAL PUMP FST Vertical & Horizontal Mount Customer Support: info@radiumauto.com Document: 19-0013 READ AND UNDERSTAND THESE INSTRUCTIONS COMPLETELY BEFORE BEGINNING INSTALLATION

More information

12CS/50CS Series Coreless Medium Pressure Filters

12CS/50CS Series Coreless Medium Pressure Filters 12CS/5CS Series Coreless Medium Pressure Filters 65 12CS/5CS Series Applications Together we can Preserve the environment. Minimize waste and promote energy efficiency. Achieve worldwide filtration solutions.

More information

Marine Fuel Filtration. Marine FBO. Features:

Marine Fuel Filtration. Marine FBO. Features: The Racor assembly is specifically designed to meet the filtration requirements of today s high pressure common rail diesel injection systems. The unit is used for fuel dispensing pumps or as a primary

More information

Troubleshooting guide for poor acceleration, black smoke, and flash code 39, SID 147, FMI 7 or 2

Troubleshooting guide for poor acceleration, black smoke, and flash code 39, SID 147, FMI 7 or 2 No.: 09 TS-17Rev2 November 25, 2009 TO: FROM: Service Locations Technical Support Development SUBJECT: EPA04 DDEC V Series 60 Engines Turbocharger Performance Diagnostic Checklist NOTE: This document supersedes

More information

Installation and Commissioning of Auxiliary Power Unit

Installation and Commissioning of Auxiliary Power Unit Models PC6012 PC6013 PC6014 PC6015 PC6022 PC6023 PC6024 Installation and Commissioning of Auxiliary Power Unit 30-871-21 Rev. E Warning & Cautions Vehicles with longer wheel bases should have the APU mounted

More information

#9040 FUEL TANK SWEEPER

#9040 FUEL TANK SWEEPER #9040 FUEL TANK SWEEPER INSTRUCTION MANUAL FILTERS AND REMOVES FINE BIO-CONTAMINANTS, ALGAE, ETC. SWEEPING PROCESS REMOVES LARGE CONTAMINANTS FROM OIL TANKS SUCH AS RUST, WATER, CRUDE AND DIRT CIRCULATES

More information

Moduflow Series IL2/RF2/CF2 Low Pressure Filters

Moduflow Series IL2/RF2/CF2 Low Pressure Filters IL/RF/CF Low Pressure Filters 35 Applications for Moduflow Filters Power Unit Fabrication Off-line Filter Loops Mobile Equipment The Moduflow filter is widely considered the most versatile filter available

More information

Installation Manual FTI-10A & FTI-20A SINGLE TANK. Automated Fuel Maintenance System FUEL TECHNOLOGIES INTERNATIONAL

Installation Manual FTI-10A & FTI-20A SINGLE TANK. Automated Fuel Maintenance System FUEL TECHNOLOGIES INTERNATIONAL Installation Manual Automated Fuel Maintenance System FTI-10A & FTI-20A SINGLE TANK FUEL TECHNOLOGIES INTERNATIONAL 05/01/2016 Rev A Fuel Technologies FTI-10A & FTI-20A Single Tank Installation Manual

More information

DeZURIK " BAW AWWA BUTTERFLY VALVES WITH EPOXY-RETAINED SEAT

DeZURIK  BAW AWWA BUTTERFLY VALVES WITH EPOXY-RETAINED SEAT DeZURIK 20 144" BAW AWWA BUTTERFLY VALVES WITH EPOXY-RETAINED SEAT Instruction D10373 April 2017 Instructions These instructions provide information about the 20 (250 F2 model only) and the 24-144 BAW

More information

INSTALLATION MANUAL. CUMMINS POWERED DODGE TRUCKS Model Year 1994 THROUGH High Performance Fuel System! With New Quick Connect Components!

INSTALLATION MANUAL. CUMMINS POWERED DODGE TRUCKS Model Year 1994 THROUGH High Performance Fuel System! With New Quick Connect Components! #2 MODEL FP-100 & FP-150 INSTALLATION MANUAL CUMMINS POWERED DODGE TRUCKS Model Year 1994 THROUGH 1998 High Performance Fuel System! With New Quick Connect Components! READ INSTRUCTIONS THOROUGHLY BEFORE

More information

SD Bendix TP-3DC Tractor Protection Valve with Double Check DESCRIPTION

SD Bendix TP-3DC Tractor Protection Valve with Double Check DESCRIPTION SD-03-3656 Bendix TP-3DC Tractor Protection Valve with Double Check 3/8"-18 NPT 3/8"-18 NPT DATE CODE STAMPED HERE LABEL WITH TP-3DC O.E. PC. NO. HERE AUXILIARY 1/4" -18 NPT QR-L FACTORY INSTALLED ON SOME

More information

Introduction Water (Coolant) Filtration Technology Coolant System Debris Fully Formulated Coolants Specifying the Right

Introduction Water (Coolant) Filtration Technology Coolant System Debris Fully Formulated Coolants Specifying the Right Water Filters Introduction.................................... 7-3 Water () Filtration Technology............ 7-3 System Debris....................... 7-3 Fully Formulated s.................... 7-3 Specifying

More information

INSTALLATION INSTRUCTIONS COOLANT TANK KIT

INSTALLATION INSTRUCTIONS COOLANT TANK KIT INSTALLATION INSTRUCTIONS COOLANT TANK KIT 2017+ Honda Civic Type-R Document: 19-0197 Support: info@radiumauto.com NOTES: Installation to be performed on engines that are completely cooled down. Do NOT

More information