Marine Fuel Filtration. Marine Turbine Series. Stage One: Separation. Stage Two: Coalescing. Stage Three: Filtration. And more

Size: px
Start display at page:

Download "Marine Fuel Filtration. Marine Turbine Series. Stage One: Separation. Stage Two: Coalescing. Stage Three: Filtration. And more"

Transcription

1 filter assemblies are designed to be installed on the vacuum side of the fuel transfer pump for best efficiency and protect precision engine components from dirt, rust, algae, asphaltines, varnishes, and especially water, which is prevalent in engine fuels. They remove contaminates from fuel using the following legendary three stage process: Stage One: Separation As fuel enters the filter assembly, it moves through the centrifuge and spins off large solids and water droplets which fall to the bottom of the collection bowl. Stage Two: Coalescing Small water droplets bead-up on the surface of the conical baffle and cartridge element. When heavy enough, they too fall to the bottom of the bowl. Stage Three: Filtration Proprietary Aquabloc II cartridge elements repel water and remove contaminants from fuel down to micron (nominal). They are waterproof and effective longer then water absorbing elements. 500MA 900MA 75500MAX 75900MAX 000MA 79000MAV And more Parker Hannifin Corporation Racor Division, PO Box 308 Modesto, CA USA Phone: Fax:

2 Applies to all models. 500 Series Specifications 500MA 500MAM 503MA 75500MAX 75500MAXM M aximum Flow Rate One Filter On-line Two Filters On-line Application Port Size NPTF Port Size (SAE J96) Height Width Depth Weight Clean Pressure Drop Maximum Pressure Water Capacity Overhead Clearance Water Removal Efficiency Operating Temperature Optional 6MM ports. 60 GPH (7 LPH) Diesel no 3/4-6.5 in. (9. cm) 5.8 in. (4.7 cm) 4.8 in. (. cm) 4.0 lb (.7 kg) 0.3 PSI (.7 kpa) 5 PSI (.0 bar) 3.7 oz (0 ml) 4.0 in. (0. cm) 60 GPH (7 LPH) Gasoline or Diesel no 3/4-6.0 in. (7.9 cm) 5.8 in. ( 4.7 cm) 4.8 in. (. cm) 5.0 lb (. kg) 0.3 PSI (.7 kpa) 5 PSI (.0 bar) 3.7 oz (0 ml) 4.0 in. (0. cm) 60 GPH (7 LPH) 60 GPH (7 LPH) 0 GPH (454 LPH) 60 GPH (7 LPH) 0 GPH (454 LPH) Diesel Diesel Gasoline or Diesel 3/8 no.5 in. (9. cm) 5.8 in. (4.7 cm) 4.8 in. (. cm) 4.0 lb (.7 kg) 0.3 PSI (.7 kpa) 5 PSI (.0 bar) 3.7 oz (0 ml) 4.0 in. (0. cm) no 34-6 no 3/4-6.5 in. (9. cm).0 in. (7.9 cm) 4.5 in. (36.8 cm) 4.5 in. (36.8 cm) 9.5 in. (4. cm) 9.5 in. (4. cm) 7 lb (7.7 kg) 8 lb (8. kg) 0.7 PSI (4.8 kpa) 0.7 PSI (4.8 kpa) 5 PSI (.0 bar) 5 PSI (.0 bar) 7.4 oz (0 ml) 7.4 oz (0 ml) 4.0 in. (0. cm) 4.0 in. (0. cm) 99% 99% 99% 99% 99% -40 o to +55 o F (-40 o to + o C) 38

3 Applies to all models. 900 Series Specifications 900MA 900MAM 903MA 75900MAX 75900MAXM M aximum Flow Rate: One Filter On-line Two Filter On-line Application Port Size Height Width Depth Weight Clean Pressure Drop Maximum Pressure Water Capacity Overhead Clearance Water Removal Efficiency 90 GPH (34 LPH) Diesel 3/8-4 (SAE J96) 7.0 in. ( 43. cm) 6.0 in. (5. cm) 7.0 in. (7.8 cm) 6.0 lb (.7 kg) 0.34 PSI (.4 kpa) 5 PSI (.0 bar) 0.3 oz (305 ml) 5.0 in. (.7 cm) 90 GPH (34 LPH) Gasoline or Diesel 3/8-4 (SAE J96) 6.5 in. (4.9 cm) 6.0 in. (5. cm) 7.0 in. (7.8 cm) 7.0 lb ( 3. kg) 0.34 PSI (.4 kpa) 5 PSI (.0 bar) 0.3 oz (305 ml) 5.0 in. (.7 cm) 90 GPH (34 LPH) 90 GPH (34 LPH) 80 GPH (68 LPH) 90 GPH (34 LPH) 80 GPH (68 LPH) Diesel Diesel Gasoline or Diesel BSPT / in. (43. cm) 6.0 in. (5. cm) 7.0 in. (7.8 cm) 6.0 lb (.7 kg) 0.34 PSI (.4 kpa) 5 PSI (.0 bar) 0.3 oz (305 ml) 5.0 in. (.7 cm) 3/8-4 (SAE J54) 3/8-4 (SAE J54) 7.0 in. (43. cm) 6.5 in. (4.9 cm) 8.8 in. (47.6 cm) 8.8 in. (47.6 cm).0 in. (7.9 cm).0 in. (7.9 cm) 3 lb (0.4 kg) 4 lb (0.9 kg).7 PSI (.7 kpa).7 PSI (.7 kpa) 5 PSI (.0 bar) 5 PSI (.0 bar) 0.6 oz (60 ml) 0.6 oz (60 ml) 5.0 in. (.7 cm) 5.0 in. (.7 cm) 99% 99% 99% 99% 99% Operating Temperature -40 o to +55 o F (-40 o to + o C) 39

4 Applies to all models. USCG 000 Series Specifications 000MA 000MAM 003MA 73000MA 73000MAM M aximum Flow Rate: One Filter On-line Two Filters On-line Application Port Size Height Width Depth Weight Clean Pressure Drop Maximum Pressure Water Capacity Overhead Clearance Water Removal Efficiency 80 GPH (68 LPH) Diesel 3/8-4 (SAE J96).0 in. (55.9 cm) 6.0 in. (5. cm) 7.0 in. (7.8 cm) 0 lb (4.5 kg) 0.5 PSI (3.4 kpa) 5 PSI (.0 bar) 0.3 oz (305 ml) 0.0 in. (5.4 cm) 80 GPH (68 LPH) Gasoline or Diesel 3/8-4 (SAE J96).5 in. (54.5 cm) 6.0 in. (5. cm) 7.0 in. (7.8 cm) lb (5.0 kg) 0.5 PSI (3.4 kpa) 5 PSI (.0 bar) 0.3 oz (305 ml) 0.0 in. (5.4 cm) 80 GPH (68 LPH) 360 GPH (363 LPH) 360 GPH (363 LPH) Diesel Diesel Gasoline or Diesel BSPT / -4.0 in. (55.9 cm) 6.0 in. (5. cm) 7.0 in. (7.8 cm) 0 lb (4.5 kg) 0.5 PSI (3.4 kpa) 5 PSI (.0 bar) 0.3 oz (305 ml) 0.0 in. (5.4 cm) ¾ -4 (SAE J476) ¾ -4 (SAE J476).0 in. (55.9 cm).5 in. (54.5 cm) 6.5 in. (4.9 cm) 6.5 in. (4.9 cm).0 in. (30.5 cm).0 in. (30.5 cm) 6 lb (.8 kg) 7 lb (. kg).7 PSI (.7kPa).7 PSI (.7 kpa) 5 PSI (.0 bar) 5 PSI (.0 bar) 0.6 oz (60 ml) 0.6 oz (60 ml) 0.0 in. (5.4 cm) 0.0 in. (5.4 cm) 99% 99% 99% 99% 99% Operating Temperature -40 o to +55 o F (-40 o to + o C) 330

5 Applies to all models. USCG 000 Series Specifications 75000MAX 75000MAXM 77000MA 79000MAV M aximum Flow Rate: One Filter On-line Two Filters On-line Three Filters On-line 80 GPH (68 LPH) 360 GPH (363 LPH) 80 GPH (68 LPH) 360 GPH (363 LPH) 540 GPH (044 LPH) 80 GPH (68 LPH) 360 GPH (363 LPH 540 GPH (044 LPH) Application Diesel Gasoline or Diesel Diesel Diesel Port Size 3/8-4 (SAE J54) 3/8-4 (SAE J54) -.5 (SAE J476) ¾ -4 (SAE J476) Height.0 in. (55.9 cm).5 in. (54.6 cm).0 in. (55.9 cm).0 in. (55.9 cm) Width 8.8 in. (47.6 cm) 8.8 in. (47.6 cm).5 in. (54.6 cm).5 in. (54.6 cm) Depth.0 in. (7.9 cm).0 in. (7.9 cm).0 in. (30.5 cm).8 in. (30.0 cm) Weight 30 lb (3.6 kg) 3 lb (4. kg) 39 lb (7.7 kg) 5 lb (3.6 kg) Clean Pressure Drop 3.7 PSI (5.5 kpa) 3.7 PSI (5.5 kpa).7 PSI (.7 kpa).5 PSI (7. kpa) Maximum Pressure 5 PSI (.0 bar) 5 PSI (.0 bar) 5 PSI (.0 bar) 5 PSI (.0 bar) Bowl Capacity 0.6 oz (60 ml) 0.6 oz (60 ml) 30.9 oz (95 ml) 30.9 oz (95 ml) Overhead Clearance 0.0 in. (5.4 cm) 0.0 in. (5.4 cm) 0.0 in. (5.4 cm) 0.0 in. (5.4 cm) Water Removal Efficiency Operating Temperature 99% 99% 99% 99% -40 o to +55 o F (-40 o to + o C) 33

6 How to Order (The example below illustrates how the part numbers are constructed). 500MA M 0 Basic Model Optional 6MM ports Use model 503MA for 3/8 NPTF Pipe Thread Add M for metal bowl. Specify: (for micron) 0 (for 0 micron) 30 (for 30 micron) Replacement Element (seals included) 00SM-OR micron Final 00TM-OR 0 micron Secondary 00PM-OR 30 micron Primary A secondary or final filter is required downstream. Mounting Information 500MA Certifications 3/8 (.0 cm) diameter clearance for fasteners. USCG 5.6 in. (4. cm) 3.6 in. (9. cm) 5.6 in. (4. cm) 33

7 Marine Fuel Filtration Replacement Parts 500MA and 503MA Part Number Description. RK888 T-handle Kit (includes o-ring) 350 T-handle O-ring. RK MA Lid Kit (white) (includes #3) Lid Gasket 4. Replacement Elements (includes #3) 00SM-OR Micron 00TM-OR 0 Micron 00PM-OR 30 Micron 5. RK5079 Return Tube Kit 6. RK5090 Mounting Bracket Kit 7. RK Body Kit (3/4-6 UNF Ports) MA Body (6MM ports) MA Body (3/8 NPTF Ports) 8. RK500B Checkball Kit (includes seal) 9. RK503D Turbine/Centrifuge Kit Bowl Gasket. RK579-0 Clear Bowl Kit (includes #9) RK530-0 Metal Bowl Kit (includes #9). RK00 Port Plug Kit Bowl Ring (includes #6) 4. RK508 Capscrew Kit (0-4 x 7/8 ) (includes 4 capscrews) 5. RK340 Drain Fitting O-ring Kit 6. RK504 Heat Deflector Shield Kit (includes # s, 4 &5) N4 Drain plug (/4 NPT) 8. RK-90 Drain Fitting Kit (includes # s & 5) Additional Parts (not shown) RK34 Drain Washer RK949 Marine Shut-off Valve Kit RK069 Water Probe Kit RK5 Complete Seal Service Kit 5335 Installation Instructions For replacement only. The Coast Guard does not accept FH units converted to MA configurations. For diesel service only. Must be used with a water Detection Kit. 333

8 How to Order (The example below illustrates how the part numbers are constructed). 900MA M 0 Basic Model Number Use model 903MA for / -4 BSPT pipe thread Add M for metal bowl. Specify: (for micron) 0 (for 0 micron) 30 (for 30 micron) Replacement Element (seals included) 040SM-OR micron Final 040TM-OR 0 micron Secondary 040PM-OR 30 micron Primary A secondary or final filter is required downstream. Mounting Information 900MA Certifications 3/8 (.0 cm) diameter clearance for fasteners. USCG 0.9 in. (7.7 cm) 3.6 in. (9. cm) Bracket height is adjustable from.0 in. (5. cm) to 5.5 in. (4.0 cm) above port center line. USCG 0.9 in. (7.7 cm) 334

9 Marine Fuel Filtration Replacement Parts 900MA and 903MA Part Number Description. RK888 T-handle Kit (includes o-ring) 350 T-handle O-ring. RK Lid Kit (includes #3) Lid O-ring 4. Replacement Element (includes #3) 040SMOR Micron Element 040TMOR 0 Micron Element 040PMOR 30 Micron Element 5. RK-93 Return Tube Kit 6. RK-953 Valve, Spring & O-ring Kit 7. RK85-0 Body Clamp Bracket Kit 8. RK900 Outer Cylinder Kit (includes # s 8 and 9) 9. RK08B Checkball and Seal Kit 0. RK06D Turbine/Centrifuge Kit. 007 Bowl O-ring. RK-606- Clear Bowl Kit (includes #0) RK734 Metal Bowl Kit RK734-0 Metal Bowl Kit (/4 NPT) 3. RK037A Bowl Ring Kit 4. RK54 Capscrew Kit (/4-0 x ) (includes 4 capscrews) 5. RK34 Bowl Drain Gasket Kit 04 Bowl Drain Washer 6. RK868 Heat Deflector Shield (includes # s 3-6) N4 Bowl Plug (/4 NPT) 8. RK-90 Drain Fitting Kit 9. RK340 Drain O-ring Kit 0. RK00 Port Plug Kit Base with / -4 BSPT ports Additional Parts (not shown) RK949 Marine Shut-off Valve Kit RK069 Water Probe Kit RK-679 Plastic Body Plug Kit RK-404 Complete Seal Service Kit 956 Installation Instructions For replacement only. The Coast Guard does not accept FH units converted to MA configurations. 335

10 How to Order (The example below illustrates how the part numbers are constructed). 000MA M 0 Basic Model Use model 003MA for / -4 BSPT pipe thread Add M for metal bowl. Add: (for micron) 0 (for 0 micron) 30 (for 30 micron) Replacement Element (seals included) 00SM-OR micron Final 00TM-OR 0 micron Secondary 00PM-OR 30 micron Primary A secondary or final filter is required downstream. Mounting Information 000MA Certifications Bracket Hight is adjustable from in. (5. cm) to 0.5 in. (6.7 cm) above port center line. 3/8 (.0 cm) diameter clearance for fasteners. 5.0 in. (.7 cm) 0.9 in. (7.9 cm) 4.5 in. (.4 cm) 0.9 in. (7.9 cm) 336

11 Marine Fuel Filtration Replacement Parts 000MA and 003MA Part Number Description. RK888 T-handle Kit (includes o-ring) 350 T-handle O-ring. RK Lid Kit (includes #3) Lid Gasket 4. Replacement Element (includes #3) 00SMOR Micron Element 00TMOR 0 Micron Element 00PMOR 30 Micron Element 5. RK-930 Return Tube Kit 6. RK-953 Valve, Spring & O-ring Kit 7. RK0 Outer Cylinder Kit (include # s 3 and 0) 8. RK85-0 Body Bracket Kit 9. RK08B Checkball and Seal Kit 0. RK06D Turbine/Centrifuge Kit. 007 Bowl O-ring. RK-606- Clear Bowl Kit (includes # s 0, 3, 5-7) RK734 Metal Bowl Kit RK734-0 Metal Bowl (/4 NPT) 3. RK037A Bowl Ring Kit (includes #8) 4. RK340 Drain Fitting O-ring 5. RK868 Heat Deflector Kit (includes # s 3-7) N4 Bowl Plug (/4 NPT) 7. RK-90 Bowl Drain Fitting Kit 8. RK34 Bowl Drain Gasket Kit 9. RK54 Capscrew Kit (4 screws) (/4-0 x ) 0. RK00 Port Plug Kit Base with / -4 BSPT ports Additional Parts (not shown) RK949 Shut-off Drain Valve Kit RK069 Water Probe Kit (MA Bowls) RK-679 Plastic Plug Kit RK-404 Complete Service Kit 956 Installation Instructions For replacement only. The Coast Guard does not accept FH units converted to MA configurations. For diesel service only. Must be used with a Water Detection Kit. 337

12 How to Order (The example below illustrates how the part numbers are constructed) MA M 0 Basic Model Add M for metal bowl Specify: (for micron) 0 (for 0 micron) 30 (for 30 micron) Replacement Element (seals included) 00SM-OR micron Final 00TM-OR 0 micron Secondary 00PM-OR 30 micron Primary A secondary or final filter is required downstream. 0 o V Mounting Information 0 o 90 o Note:. Mount filter assembly as close to vertical (V) as possible. For best efficiency, do not exceed 0 o from V.. Do not remove valve fittings as they are integral components to the valve body. 3/8 (.0 cm) diameter clearance for fasteners. Standard Fuel Inlet 3/4-4 NPT 4.5 in. (.4 cm) Standard Fuel Outlet 3/4-4 NPT.0 in. (30.5 cm) 338

13 Replacement Parts MA Part Number Description. 000MA Refer to model 000MA for a complete part breakdown RK895 Clamp Bracket Kit -69 Dual unit Bracket 895 Clamp Bracket Assembly Outlet Manifold Elbow Fitting (Parker # ) Inlet Manifold 73000MA Certifications Additional Parts (not shown) RK949 UL Listed Marine Valve Kit (use two for use with this unit) 953 Installation Instructions For water detection kits see the marine Accessories. 339

14 How to Order (The example below illustrates how the part numbers are constructed) MAX M 0 Basic Model Add M for metal bowl Add: (for micron) 0 (for 0 micron) 30 (for 30 micron) Replacement Element (seals included) 00SM-OR micron Final/Secondary 00TM-OR 0 micron Primary/Secondary 00PM-OR 30 micron Primary A secondary/final filter is required downstream. 0 o V Mounting Information 0 o 90 o Note:. Mount filter assembly as close to vertical (V) as possible. For best efficiency, do not exceed 0 o from V.. Do not remove valve fittings as they are integral components to the valve body. 3/8 in. (.0 cm) diameter clearance for fasteners. 5.0 in. (.7 cm) 6.34 in. (6. cm) 6.34 in. (6. cm).7 in. (3. cm) 340

15 Replacement Parts MAX Part Number Description. 500MA Refer to model 500MA for a complete part breakdown.. RK5390 Valve Kit RK-959 Valve Replacement Kit 3. RK539 Rigid Tubing Kit 75500MAX Certifications 4. RK5378 Body Clamp Bracket Kit (One-Piece) RK5300 Body Clamp Bracket Kit (Three-Piece) 5. RK539 Main Bracket Kit 6. RK9476 Gauge Kit Additional Parts (not shown) RK949 UL Listed Marine Drain Kit (two for use with this unit) 5349 Installation Instructions 34

16 How to Order (The example below illustrates how the part numbers are constructed) MAX M 0 Basic Model Add M for metal bowl Add: (for micron) 0 (for 0 micron) 30 (for 30 micron) Replacement Element (seals included) 040SM-OR micron Final 040TM-OR 0 micron Secondary 040PM-OR 30 micron Primary A secondary or final filter is required downstream. 0 o V Mounting Information 0 o 90 o Note:. Mount filter assembly as close to vertical (V) as possible. For best efficiency, do not exceed 0 o from V.. Do not remove valve fittings as they are integral components to the valve body. 3.5 in. (8.9 cm) 7.6 in. (44.8 cm) 3/8 (.0 cm) diameter clearance for fasteners. NOTE: The Inlet / Outlet Port Male Fittings are 7/8-4 UNF threads with 37 o Flare (JIC); SAEJ54. These permanent fittings must not be removed. Damage to the valve may result. See fittings selection chart in Accessories Section to adapt to your fuel system piping requirements. 34

17 Replacement Parts MAX Part Number Description. 900MA Refer to model 900MA for a complete part breakdown.. RK9473 Valve Kit RK9506 Valve Service Kit 75900MAX Certifications 3. RK9475 Rigid Tubing Kit 4. RK9486 Dual unit Bracket Kit 5. RK9476 Gauge Assembly Kit Additional Parts (not shown) RK949 UL Listed Marine Valve Kit (two for use with this unit) 9536 Installation Instructions 343

18 How to Order (The example below illustrates how the part numbers are constructed) MAX M 0 Basic Model Add M for metal bowl. Add: (for micron) 0 (for 0 micron) 30 (for 30 micron) Replacement Element (seals included) 00SM-OR micron Final/Secondary 00TM-OR 0 micron Primary/Secondary 00PM-OR 30 micron Primary A secondary or final filter is required downstream. 0 o V Mounting Information 0 o 90 o Note:. Mount filter assembly as close to vertical (V) as possible. For best efficiency, do not exceed 0 o from V.. Do not remove valve fittings as they are integral components to the valve body. 7.6 in cm 3/8 (.0 cm) diameter clearance for fasteners. 3.9 in. 9.8 cm NOTE: The Inlet / Outlet Port Male Fittings are 7/8-4UNF threads with 37 o Flare (JIC); SAEJ54. These permanent fittings must not be removed. Damage to the valve may result. See fittings selection chart in Accessories Section to adapt to your fuel system piping requirements. 344

19 Replacement Parts MAX Part Number Description. 000MA Refer to model 000MA for a complete part breakdown.. RK9473 Valve Assembly Kit RK9506 Valve Service Kit 75000MAX Certifications 3. RK9475 Rigid Tubing Assembly Kit 4. RK-777 Dual unit Bracket Kit 5. RK9476 Gauge Assembly Kit Additional Parts (not shown) RK949 UL Listed Marine Drain Valve Kit (two for use with this unit) 9536 Installation Instructions 345

20 How to Order (The example below illustrates how the part numbers are constructed) MA M 0 Basic Model Add M for metal bowl. Add: (for micron) 0 (for 0 micron) 30 (for 30 micron) Replacement Element (seals included) 00SM-OR micron Final/Secondary 00TM-OR 0 micron Primary/Secondary 00PM-OR 30 micron Primary A secondary or final filter is required downstream. Mounting Information 3/8 (.0 cm) diameter clearance for fasteners 5.9 in. (5. cm).8 in. (3.4 cm) 7.8 in. (45. cm) 346

21 Replacement Parts MA Part Number Description. 000MA Refer to model 000MA for a complete part breakdown.. RK895 Clamp Bracket Kit -63 Triple unit Bracket 895 Clamp Bracket Assembly Inlet Manifold Elbow Fitting (Parker # ) Outlet Manifold 77000MA Certifications Additional Parts (not shown) RK949 UL Listed Marine Drain Valve Kit (three for use with this unit) 953 Installation Instructions For Water Detection Kits and Manifold Conversion Kits, see the Accessories Section. 347

22 How to Order (The example below illustrates how the part numbers are constructed) MAV M 0 Basic Model Add M for metal bowl. Add: (for micron) 0 (for 0 micron) 30 (for 30 micron) Replacement Element (seals included) 00SM-OR micron Final 00TM-OR 0 micron Secondary 00PM-OR 30 micron Primary A secondary or final filter is required downstream. Mounting Information 3/8 (.0 cm) diameter clearance for fasteners. 5.9 in. (5. cm) 7.8 in. (45. cm) 348

23 Replacement Parts MAV Part Number Description 000MA Refer to model 000MA for a complete part breakdown. -63 Triple unit Bracket Inlet Manifold Clamp Bracket -76 U Bracket Outlet Manifold 6 RK073 / Ball Valve Kit 7-66 Formed Tubing Assembly Additional Parts (not shown) RK949 UL Listed Marine Drain Valve Kit (three for use with this unit) 953 Installation Instructions For water detection kits and manifold conversion kits - see the marine accessories section MAV Certifications 349

24 Test Data (Test results are from controlled laboratory testing, field results may vary.) 500MA 500MAM 900MA 900MAM 000MA 000MAM 73000MA 350

25 75500MAX 75900MAX 75000MAX 77000MA 79000MAV 35

26 Installation Instructions New filter installations must be filled with fuel and the fuel system must be adequately primed following the engine manufacturer s recommendations. Existing installation difficulties are usually associated with improper priming procedures or damage to the unit or fuel system. The result is either internal air suction or external fuel leakage. Diagnose with the following steps:. Check fuel tank level and verify fuel delivery valves are open.. Verify T-handle, bowl fasteners and fuel fittings are tight and bowl drain is closed. 3. If element is new, check potential restriction at fuel tank draw tube. An in-tank strainer may be plugged. 4. Review other troubleshooting instructions to uncover other solutions. Correct external fuel leaks immediately! These conditions result in reduced engine performance such as: hard starting, stalling, reduced power and fire hazards. Correct Application It is very important that Turbine Series filter assemblies are not under specified for the application. The maximum fuel flow rating of the filter assembly must not be exceeded; doing so will reduce efficiency and de-gas (pull air from) the fuel. Filter Elements Replacement elements are available in, 0 and 30 micron ratings (nominal). Filtration needs are based on application, fuel quality, maintenance schedules and operating climates. A simple rule to remember is... the finer the filtration, the more frequent the filter change interval. Always carry extra replacement elements with your equipment as one tankful of excessively contaminated fuel can plug an element quickly. When clogged to maximum capacity, elements will have a brown to black color or tar like contaminants may be present - this is normal. An appearance of a multi-colored slime (which may have a foul odor) is an indication of microbiological contamination. This condition must be treated immediately. Racor offers a wide variety of gasoline and diesel additives to prevent and treat these problems; see Additives section of this catalog. Severe conditions must be corrected by a repair facility. Never operate a filter assembly without the element in place. The element safety valve on the fuel return tube will not expose the outlet hole if the element is removed. Instead, punch the emergency tab on the top of the element and leave in place. Warning! Puncturing the emergency tab will bypass all filtration and send unfiltered fuel to your engine. Service the element as soon as possible to avoid harmful contaminants flowing downstream to the engine. Water Sensors This feature alerts the operator of a high-water condition. The bowl must be drained of water at the earliest convenience. A Racor water detection module is needed to work with the in-bowl sensor. The unit should activate when the water reaches the sensor tips (and when they measure below 47,000 or 00,000 ohms of resistance, depending on the detection module used). If not, the tips may be fouled with a coating. Remove the sensor and clean the tips with a cloth. Run a jumper wire between the tips with the ignition ON to test the system. Difficulties usually lie in the wire connections, power source, or an independent ground. 35

27 All filters are 00% tested to ensure a leak-proof, quality product. Apply Parker Super O-lube (part number RK3605) or equivalent to all seals at major attachment points to maintain integrity, seal elasticity, to fill small voids and provide protection from degradation. Perform the following checks with the engine OFF (and applicable valves closed). For replacement parts, refer to the appropriate Replacement Parts section of this catalog. Damaged, worn, or dirty seals will allow air ingestion. Inspect and replace all seals as needed. Lube all seals with Parker Super O-lube. Clean sealing surfaces of dirt or debris every time element is replaced. Hand tighten T-handle; do not use tools! If element is changed or assembly drained for any reason, repriming assembly (filling with fuel) may be necessary. Fill to just above top of Do not overtighten carriage bolt as this may distort cylinder roundness. Do not overtighten self-tapping screws; this may strip the treads. After disassembly, start screws by hand prior to using tools. Specification: 55 to 65 in. The hollow aluminum check-ball floats up against the seal when the fuel is stopped thus preventing fuel bleed-back. If your unit looses prime, inspect upstream hose connections first, otherwise, disassemble the unit and inspect the seal and ball. Drain water before it reaches this level. Air bubbles or fuel leakage appearing from drain may indicate that drain is closed completely or that seal has been clogged with contaminants. Tighten drain and inspect: If self-venting drain will not work when opened, it may be clogged. Cycle drain (open-close) or attach a hose and briefly apply air (<-3 PSI with T-handle and lid removed) to dislodge contaminants. Element should be replaced every 0,000 miles every 500 hours, every other oil change, annually or at first indication of power loss, whichever occurs first. Construction and agricultural equipment should change element every 300 hours. SAE O-ring ports should have a smooth angled seat for sealing. Do not scratch this surface. Check O-ring for damage. Replace if necessary. Heater feed-thru O-ring must not be damaged or swollen. Tighten snugly. Specification: 5 to 0 in. lbs. Air bubbles appearing from turbine are an indication of an upstream leak between Racor inlet and fuel tank pick-up tube. A water sensor plug is standard equipment on new assemblies. Water sensor kits are available as accessories; see the Accessories section of this catalog. Tighten plug or water sensor snugly. Specification: 5 to 0 in. lbs. Water sensors activate when water contacts the sensor tips. Air bubbles or fuel leakage appearing from sensor area may indicate that it is loose or O-ring is damaged. Tighten or diassemble and inspect. Specification: 5 to 0 in. lbs. 353

All Racor filter materials and seals are compatible with ultra-low sulphur diesel (ULSD) fuel and B2 to B20 Biodiesel. See Racor bulletin 7679.

All Racor filter materials and seals are compatible with ultra-low sulphur diesel (ULSD) fuel and B2 to B20 Biodiesel. See Racor bulletin 7679. 000MA Water-in-fuel sensor and indicator. MA units have shielded see-thru bowls; MAM bowls are all-metal. UL-listed drain valve and water sensor probe options are available. Turbine Series Electric Primer

More information

Marine Turbine Series

Marine Turbine Series 1000MA Water-in-fuel sensor and indicator. All Racor filter materials and seals are compatible with ultra-low sulphur diesel (ULSD) fuel and B2 to B20 Biodiesel. See Racor bulletin 7679. The complete Primer

More information

Introduction. Marine Turbine Series. Model Illustrations. Special Notes. Specifications 77/1000MA 73/1000MA 75/500MAX 75/900MAX 79/1000MAV 75/1000MAX

Introduction. Marine Turbine Series. Model Illustrations. Special Notes. Specifications 77/1000MA 73/1000MA 75/500MAX 75/900MAX 79/1000MAV 75/1000MAX Introduction Model Illustrations 5MA 5MAM 9MA 1MA 7/1MA 77/1MA 75/5MAX Special Notes 75/9MAX 75/1MAX 79/1MAV 1. See--thru bowl MA / MAX / MAV units are approved for Diesel service only. UL Listed, USCG

More information

900MA/MAM and 1000MA/MAM (for marine applications)

900MA/MAM and 1000MA/MAM (for marine applications) 900MA/MAM and 1000MA/MAM (for marine applications) Fuel Filter/Water Separator Instruction Part Number 19526 Rev B Racor Turbine Series fuel filter/ water separator protects the precision components of

More information

Racor 75500FGX Turbine Series fuel

Racor 75500FGX Turbine Series fuel Installation Instructions 75500FGX Fuel Filter Racor 75500FGX Turbine Series fuel filter/water separator assemblies are designed to be installed on the vacuum side of the fuel transfer pump for best efficiency

More information

Marine Fuel Filtration Marine 800 Series

Marine Fuel Filtration Marine 800 Series Racor recyclers offer large diesel engine operators both ease of maintenance and continuous engine operation. Continuous operations include filter changeouts and the draining of accumulated water from

More information

General The Racor Marine Diesel Spin--on Series feature a variety of compact sizes to fit most installations and cramped engine compartments.

General The Racor Marine Diesel Spin--on Series feature a variety of compact sizes to fit most installations and cramped engine compartments. Selection Selection Information General The Racor Marine Diesel Spin--on Series feature a variety of compact sizes to fit most installations and cramped engine compartments. Mounting Heads: These units

More information

75500MAX Series and 75500MAXM Series

75500MAX Series and 75500MAXM Series 75500MAX Series and 75500MAXM Series Marine Fuel Filter/Water Separators Instruction Part Number 15349 Rev E Racor Turbine Series fuel filter/ water separators protect the precision components of your

More information

900FH and 1000FH Turbine Series Fuel Filter/Water Separators Installation, Operation, and Service Information

900FH and 1000FH Turbine Series Fuel Filter/Water Separators Installation, Operation, and Service Information 900FH and 1000FH Turbine eries Fuel Filter/Water eparators Installation, Operation, and ervice Information Overview The 900FH and 1000FH Turbine eries filter assemblies protect precision engine components

More information

120RMAM Marine Series Fuel Filter/Water Separators

120RMAM Marine Series Fuel Filter/Water Separators 10RMAM Marine Series Fuel Filter/Water Separators Instruction Part Number 1945 Rev A Overview The 10RMAM fuel filter/water separator features 1/4-18 NPTF inlet and outlet fuel ports and a unitized mounting

More information

660R-RAC Series. Gasoline Fuel Filter/Water Separators. Overview: Contact Information: Product Features: Instruction Part Number Rev F

660R-RAC Series. Gasoline Fuel Filter/Water Separators. Overview: Contact Information: Product Features: Instruction Part Number Rev F 660R-RAC Series Gasoline Fuel Filter/Water Separators Instruction Part Number 1385 Rev F Overview: Don t be caught in the water without one of these Racor gasoline spin on series filters. These filters

More information

320R-RAC Series. Gasoline Fuel Filter/Water Separators. Overview: Contact Information: Product Features: Instruction Part Number Rev.

320R-RAC Series. Gasoline Fuel Filter/Water Separators. Overview: Contact Information: Product Features: Instruction Part Number Rev. 30R-RAC Series Gasoline Fuel Filter/Water Separators Instruction Part Number 37 Rev. D Overview: Racor 30R-RAC series filters are designed for high-performance applications, which means your engine will

More information

Product Features: Removes 99% of free water. Available with 2, 10, or 30 micron Aquabloc II media

Product Features: Removes 99% of free water. Available with 2, 10, or 30 micron Aquabloc II media 120A and 120B Series Fuel Filter/Water Separators Instruction Part Number 10219 Rev B Overview: 120A and 120B fuel filter/water separators are designed to be installed on the suction side of the fuel system

More information

Marine Fuel Filtration. Marine FBO. Features:

Marine Fuel Filtration. Marine FBO. Features: The Racor assembly is specifically designed to meet the filtration requirements of today s high pressure common rail diesel injection systems. The unit is used for fuel dispensing pumps or as a primary

More information

400 Series Spin-on Fuel Filter/Water Separators

400 Series Spin-on Fuel Filter/Water Separators 00 Series Spin-on Fuel Filter/Water Separators Instruction Part Number 09 Rev G 00 Series fuel filter/water separators are designed to handle today s tough fuel filtration problems and can be used anywhere

More information

Product Features. Easy installation. Pump adds only 3.3 to the overall assembly height. 60 GPH (227 LPH) flow rate while in priming mode.

Product Features. Easy installation. Pump adds only 3.3 to the overall assembly height. 60 GPH (227 LPH) flow rate while in priming mode. Primer Pump Kits RKP1912 (12 vdc) and RKP1924 (24 vdc) Instruction Part Number 14356 Rev C Primer pump kits are an innovative and proprietary system consisting of a prescreen filter, a flow by-pass circuit,

More information

MARINE. Diesel Fuel/Water Separators. Installation. Operation. Parts. Service Information

MARINE. Diesel Fuel/Water Separators. Installation. Operation. Parts. Service Information Diesel Fuel/Water Separators stallation Operation Parts Service formation INSTALLATION A. Filter Mounted Above Fuel Storage Tank. Select a location in the fuel line between the fuel tank and the fuel pump,

More information

Section: B Marine Fuel Filtration

Section: B Marine Fuel Filtration Section: Marine Fuel Filtration aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Marine Fuel Filtration Table of Contents

More information

DIESEL FUEL FILTER/WATER SEPARATORS & Recycler Systems

DIESEL FUEL FILTER/WATER SEPARATORS & Recycler Systems DIESEL FUEL FILTER/WATER SEPARATORS & Recycler Systems DAHL DIESEL FUEL FILTER/WATER SEPARATORS REMOVE DIESEL FUEL SYSTEM PROBLEMS ALONG WITH WATER Water and solid contaminants displace the diesel fuel

More information

Marine Retail Basics. Product Overview

Marine Retail Basics. Product Overview Marine Retail Basics Product Overview Diesel Fuel Filter/Water Separator The Racor s fuel filter/water separators feature a variety of compact sizes to fit the most cramped engines. Most units feature

More information

Marine Gasoline Products

Marine Gasoline Products 025 -RAC eries Marine Gasoline Products In -line Fuel Filters Being on the water is fun, having water in your fuel is not. More than ever, today s high performance gasoline engines require clean, dry fuel.

More information

2009 PRICE LIST. Prices FOB Ft. Myers, FL. Effective May 15, Subject to change without notice Suggested MODEL PORT SIZE HP RANGE

2009 PRICE LIST. Prices FOB Ft. Myers, FL. Effective May 15, Subject to change without notice Suggested MODEL PORT SIZE HP RANGE 2009 PRICE LIST Prices FOB Ft. Myers, FL. Effective May 15, 2009. Subject to change without notice. INLINE FUEL CONDITIONER 2009 Suggested MODEL PORT SIZE HP RANGE US Retail Price LG-X 200 1/4" NPT or

More information

200 & 300 SERIES Diesel Fuel/Water Separators

200 & 300 SERIES Diesel Fuel/Water Separators 200 & 300 SERIES Diesel Fuel/Water Separators Installation Operation Parts Service Information INSTALLATION A. FILTER MOUNTED ABOVE FUEL STORAGE TANK 1. Select a location in the fuel line between the fuel

More information

Gasoline Fuel Filters. For Marine Applications

Gasoline Fuel Filters. For Marine Applications Gasoline Fuel Filters For Marine Applications Complete Protection On The Water Every time you squeeze the trigger, you threaten your engines life. More than ever, today s high-performance gasoline inboard

More information

Section: D Alternative Fuel

Section: D Alternative Fuel Section: D Alternative Fuel aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding C Alternative Fuel Table of Contents Alternative

More information

SNAPP. The One-Piece, High-Performance Snap-In Fuel Filter Water Separator. Next

SNAPP. The One-Piece, High-Performance Snap-In Fuel Filter Water Separator. Next SNAPP The One-Piece, High-Performance Snap-In Fuel Filter Water Separator 2 Now, getting the fuel filtration you need is a SNAPP. SNAPP. The fuel filter change that changes everything. The world turns

More information

SNAPP. The One-Piece, High-Performance Snap-In Fuel Filter Water Separator

SNAPP. The One-Piece, High-Performance Snap-In Fuel Filter Water Separator SNAPP The One-Piece, High-Performance Snap-In Fuel Filter Water Separator Now, getting the fuel filtration you need is a SNAPP. SNAPP. The fuel filter change that changes everything. The world turns to

More information

Marine Retail Basics. Product Overview

Marine Retail Basics. Product Overview Marine Retail Basics Product Overview NEW PRODUCTS SNAPP. The fuel filter change that changes everything. SNAPP is big protection for small engines with fuel flows up to 26 gph and makes every filter change

More information

SHURFLO HIGH FLOW SYSTEM II 10.0 GPM MARINE FRESH WATER SYSTEM PRODUCT TECHNICAL DATA SHEET

SHURFLO HIGH FLOW SYSTEM II 10.0 GPM MARINE FRESH WATER SYSTEM PRODUCT TECHNICAL DATA SHEET SHURFLO HIGH FLOW SYSTEM II 10.0 GPM MARINE FRESH WATER SYSTEM PRODUCT TECHNICAL DATA SHEET OEM: AFTERMARKET: 4558-153-E75 4558-153-E75 APPLICATION: Multi-fixture Marine fresh water system installation.

More information

Dual/Triple Manifold Water Filtration Systems Instruction Manual

Dual/Triple Manifold Water Filtration Systems Instruction Manual 3M TM Water Filtration Products Dual/Triple Manifold Water Filtration Systems Instruction Manual High Flow Series Water Filtration Systems Installer: Please leave this manual with owner/operator. 3M Water

More information

Service Access Cover. Vacuator Valve. Accessories

Service Access Cover. Vacuator Valve. Accessories Under Hood Mount, Two-Stage Filtration For Large Construction & Mining Equipment The FTG Cycloflow Air Cleaner is another two-stage air cleaner with a built-in pre-cleaner. This air cleaner has axial seal

More information

A Filtration Primer. Filter Elements. High Pressure Filters. Tank-Mounted, Return Line and Medium Pressure Filters. Water Service Filters

A Filtration Primer. Filter Elements. High Pressure Filters. Tank-Mounted, Return Line and Medium Pressure Filters. Water Service Filters A Filtration Primer Filter Elements High Pressure Filters Tank-Mounted, Return Line and Medium Pressure Filters Water Service Filters Section 6 Reservoir Accessories SCHROEDER INDUSTRIES 259 Principles

More information

Fuel Pro Series Filter/Separator/Warmer Installation Instructions

Fuel Pro Series Filter/Separator/Warmer Installation Instructions Fuel Pro Series Filter/Separator/Warmer Installation Instructions Standard and Plus Series A B C D Vent Cap and Assembly (part no SP1053) Includes Vent Cap and Vent Cap Seal Part Description Part Number

More information

Marine Filtration Systems

Marine Filtration Systems Marine Filtration Systems Table of Contents Troubleshooting Guide...3 SNAPP Fuel Filter Water Separator...4 Turbine Series... 5-9 Diesel Spin-on Series... 10-11 Fuel Conditioning Modules... 12-13 Filter

More information

S Some FTG Customers:

S Some FTG Customers: Some FTG Customers: FTG Product Lines FTG, Inc. is a minority-owned small business with empowered employees who are entrepreneurs. We develop or offer innovative solutions for customers who demand quality

More information

SERVICING INSTRUCTIONS

SERVICING INSTRUCTIONS TSP Series 66 Triplex Plunger Pump SERVICING INSTRUCTIONS TRIPLEX TRIPLEX SERVICING PUMP PROCEDURES Valve Replacement: All inlet and discharge valves can be serviced without disrupting the inlet or discharge

More information

OWNER S MANUAL D.E. CARTRIDGE. Installation Operation Parts. Models PCDE-30 PCDE-40

OWNER S MANUAL D.E. CARTRIDGE. Installation Operation Parts. Models PCDE-30 PCDE-40 D.E. CARTRIDGE OWNER S MANUAL Installation Operation Parts Models PCDE-30 PCDE-40 2200 East Sturgis Road, Oxnard, CA 93030 Ph. (805) 981-0262 Fax (805) 981-9403 www.waterwayplastics.com waterway@waterwayplastics.com

More information

#9040 FUEL TANK SWEEPER

#9040 FUEL TANK SWEEPER #9040 FUEL TANK SWEEPER INSTRUCTION MANUAL FILTERS AND REMOVES FINE BIO-CONTAMINANTS, ALGAE, ETC. SWEEPING PROCESS REMOVES LARGE CONTAMINANTS FROM OIL TANKS SUCH AS RUST, WATER, CRUDE AND DIRT CIRCULATES

More information

Racor Filter Division Europe Distribution. Fuel, Air and Hydrocarbon Filtration Solutions ENGINEERING YOUR SUCCESS.

Racor Filter Division Europe Distribution. Fuel, Air and Hydrocarbon Filtration Solutions ENGINEERING YOUR SUCCESS. aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Racor Filter Division Europe Distribution Fuel, Air and Hydrocarbon

More information

Low Profile J Series Power Unit with Vane Pump

Low Profile J Series Power Unit with Vane Pump Low Profile J Series Power Unit with Vane Pump READ ALL INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING

More information

Operating and Installation Instructions

Operating and Installation Instructions Model Number 40401-c (-sp) Electronic Fuel Pump Operating and Installation Instructions This Product is Patent Pending. Application available upon request CAUTION! This product is to be installed only

More information

Fuel Pro FH230 Series Filter/Separator/Warmer Installation Instructions

Fuel Pro FH230 Series Filter/Separator/Warmer Installation Instructions Fuel Pro FH230 Series Filter/Separator/Warmer Installation Instructions A B C Vent Cap and Assembly (part no. 3944440 S) Includes Vent Cap and Vent Cap Seal Parts List Part Description Part Number A Collar

More information

Valves. E Valves. Multiple Hydraulic System Applications

Valves. E Valves. Multiple Hydraulic System Applications s Multiple Hydraulic System Applications Parker Check s are unidirectional flow control devices used primarily in hydraulic systems to eliminate potential damage caused by fluid back pressure. Offered

More information

Pneumatic High-Viscosity Filtration System Instruction Manual

Pneumatic High-Viscosity Filtration System Instruction Manual Pneumatic High-Viscosity Filtration System Instruction Manual P/N: 61512 05/17 1 2 Pneumatic High Viscosity Filtration Systems PN: 61512 14 April, 2009 rev A 36933 Pneumatic Hand Cart HV Filtration System

More information

Industrial Pro FH234 Series Filter/Separator/Warmer Installation Instructions

Industrial Pro FH234 Series Filter/Separator/Warmer Installation Instructions Filter/Separator/Warmer Installation Instructions P M O A B C G U R H I OR N E X J D K L F VENT CAP FUEL PRO COLLAR Note: The Collar/Vent Cap Wrench is only supplied with the Single, Dual and Triple units

More information

DODGE COOL LUBE 2 for Sleevoil Pillow Blocks Part Numbers , , ,

DODGE COOL LUBE 2 for Sleevoil Pillow Blocks Part Numbers , , , DODGE COOL LUBE for Sleevoil Pillow Blocks Part s 063487, 063488, 07889, 07890 These instructions must be read thoroughly before installing or operating this product. WARNING: To ensure the drive is not

More information

QuickServe Online ( ) ISB6.7 CM2350 B101 Service Manual

QuickServe Online ( ) ISB6.7 CM2350 B101 Service Manual Page 1 of 31 (/qs3/pubsys2/xml/en/manual/2883567/2883567-titlepage.html) Select Service Tools Recommended Cummins Service Tools 0.043 inch orificed diagnostic fuel line, Part Number 3164621 Diagnostic

More information

Section 10 Chapter 17

Section 10 Chapter 17 Section 10 Chapter 17 24 Valve, 8.3 Liter Engine Air Intake System Note: All coding used in the 8.3 Liter and 9 Liter engine manuals are Cummins engine codes. These engine codes have no meaning to New

More information

LABORATORY ZERO AIR GENERATOR MODEL N-GC1500 USER S MANUAL

LABORATORY ZERO AIR GENERATOR MODEL N-GC1500 USER S MANUAL LABORATORY ZERO AIR GENERATOR MODEL N-GC1500 USER S MANUAL Content 1. Introduction...2 2. Important safety instruction...3 3. System component...4 4. Engineering design overview...5 5. Installation...6

More information

FH 230 SERIES FUEL PRO

FH 230 SERIES FUEL PRO FH 230 SERIES FUEL PRO D IESEL F UEL F ILTRATION S YSTEM All-In-One Fuel Filter, Fuel- Water Separator and Fuel Heater Seeing is Believing Eliminates unnecessary changes and maintenance Extended filter

More information

B21 Series BASOTROL Gas Valve

B21 Series BASOTROL Gas Valve Installation Instructions B21 Issue Date September 19, 2017 Installation IMPORTANT: These instructions are intended as a guide for qualified personnel installing or servicing BASO Gas Products. Carefully

More information

SERVICE PARTS LIST SPECIFY CATALOG NO. AND SERIAL NO. WHEN ORDERING PARTS 13 HP DIRECT DRIVE PRESSURE WASHER CATALOG NO

SERVICE PARTS LIST SPECIFY CATALOG NO. AND SERIAL NO. WHEN ORDERING PARTS 13 HP DIRECT DRIVE PRESSURE WASHER CATALOG NO SPECIFY CATALOG NO. AND SERIAL NO. WHEN ORDERING PARTS HP DIRECT DRIVE PRESSURE WASHER CATALOG NO. 555-22 SERVICE PARTS LIST STARTING SERIAL NUMBER B06A REVISED BULLETIN PAGE OF BULLETIN NO. 5-20-000 DATE

More information

M-3025CB-AV Fuel Pump

M-3025CB-AV Fuel Pump SAVE THESE INSTRUCTIONS M-3025CB-AV Fuel Pump Owner s Manual TABLE OF CONTENTS General Information... 2 Safety Instructions... 2 Installation... 3 Operation... 4 Maintenance... 4 Repair... 5 Troubleshooting...

More information

CARTRIDGE FILTER SYSTEMS OWNER S MANUAL

CARTRIDGE FILTER SYSTEMS OWNER S MANUAL CARTRIDGE FILTER SYSTEMS OWNER S MANUAL Installation Operation Parts Designed, Engineered & Manufactured in the USA. 2017 Waterway Plastics 2200 East Sturgis Road, Oxnard CA 93030 Phone 805.981.0262 Fax

More information

DIESEL FUEL FILTER/WATER SEPARATORS & Re c ycler/blender Syste m s

DIESEL FUEL FILTER/WATER SEPARATORS & Re c ycler/blender Syste m s DIESEL FUEL FILTER/WATER SEPARATORS & Re c ycler/blender Syste m s DAHL DIESEL FUEL FILTER/WATER SEPARATORS REMOVE DIESEL FUEL SYSTEM PROBLEMS ALONG WITH WATER Water and solid contaminants displace the

More information

Scale Feeder Manifold Water Filtration System Instruction Manual

Scale Feeder Manifold Water Filtration System Instruction Manual 3M TM Water Filtration Products Scale Feeder Manifold Water Filtration System Instruction Manual For SF1XX High Flow Series Water Filtration Systems Installer: Please leave this manual with owner/operator.

More information

STS SERIES. Enclosed Automated Fuel Maintenance Systems (STS)

STS SERIES. Enclosed Automated Fuel Maintenance Systems (STS) STS SERIES Enclosed Automated Fuel Maintenance Systems (STS) AXI s Enclosed Automated Fuel Maintenance Systems are programmable and automated self-contained, stand-alone fuel filtration, separation, and

More information

Marine FUEL FILTER / WATER SEPARATOR Product Guide

Marine FUEL FILTER / WATER SEPARATOR Product Guide AUTOMOTIVE MACHINERY MINING www.griffinfilter.com Marine FUEL FILTER / WATER SEPARATOR Product Guide About Griffin Group GRIFFIN group is a global provider of products and services for the filtration

More information

Diesel Pro FH235, FH236 and FH241 Series Filter/Separator/Warmer Installation Instructions

Diesel Pro FH235, FH236 and FH241 Series Filter/Separator/Warmer Installation Instructions A FH235 Cover Assembly Includes Vent Cap, Vent Cap O-Ring, Collar, Cover, Cover O-Ring, and Spring F E C D I Diesel Pro 235 Diesel Pro FH235, FH236 and FH241 Series Filter/Separator/Warmer Installation

More information

SHURFLO AQUA KING II SUPREME 5.0 MARINE FRESH WATER PUMP PRODUCT TECHNICAL DATA SHEET

SHURFLO AQUA KING II SUPREME 5.0 MARINE FRESH WATER PUMP PRODUCT TECHNICAL DATA SHEET SHURFLO AQUA KING II SUPREME 5.0 MARINE FRESH WATER PUMP PRODUCT TECHNICAL DATA SHEET OEM: AFTERMARKET: 158-16-A75 158-16-E75 APPLICATION: Multi-fixture Marine fresh water pump installation. This pump

More information

Marine Filtration Systems

Marine Filtration Systems Marine Filtration Systems Table of Contents Troubleshooting Guide...3 SNAPP Fuel Filter Water Separator...4 Turbine Series... 5-9 Diesel Spin-on Series... 10-11 Fuel Conditioning Modules... 12-13 Filter

More information

Model 8329 Table of Contents

Model 8329 Table of Contents SERVICE & OPERATING MANUAL Original Instructions Instructions Sheet: 670991 Model 8329 Table of Contents Engineering Data and Temperature Limitations... 1 Performance Curve... 2 Dimensions... 3 Metric

More information

FPS- 80. Manual. Reverso Pumps, Inc. Ph: (954)

FPS- 80. Manual. Reverso Pumps, Inc.   Ph: (954) FPS- 80 Manual Table of Contents System Overview... 1 Control Panel Overview... 2 Technical Specifications... 3 Electrical and Installation... Tank Diagrams... 5 Initial Setup... 6 Digital Timer Instructions:

More information

Fuel Filtration Systems. Products and Custom Solutions

Fuel Filtration Systems. Products and Custom Solutions Fuel Filtration Systems Products and Custom Solutions About Racor About Racor Parker Hannifin Corporation, global leader in motion and control technologies, delivers an unmatched breadth of engineered

More information

Flow Max Fluid Pump. by Duraself OEM INSTALLATION MANUAL

Flow Max Fluid Pump. by Duraself OEM INSTALLATION MANUAL Flow Max Fluid Pump by Duraself OEM INSTALLATION MANUAL TABLE OF CONTENTS System and Safety Information 2 Resources Required 3 Installation 3 General Installation Instructions 3 Mounting Instructions 3

More information

Purging Air From Divider Block Lubrication Systems

Purging Air From Divider Block Lubrication Systems FROST ENGINEERING SERVICE Purging Air From Lubrication Systems A D I V I S I O N O F G E C S E Y S A L E S & S E R V I C E DESCRIPTION Divider block lubrication systems operate correctly only when all

More information

Fuel Catalyst AFC-705 / AFC-805

Fuel Catalyst AFC-705 / AFC-805 Fuel Catalyst AFC-705 / AFC-805 ALGAE-X Fuel Catalyst is a powerful full spectrum additive and tank cleaning agent. It provides superior fuel quality for engines and storage tanks, lowering operating cost,

More information

INSTALLATION AND OPERATING INSTRUCTIONS FOR CONCRETE VAULT TYPE UNITS

INSTALLATION AND OPERATING INSTRUCTIONS FOR CONCRETE VAULT TYPE UNITS INSTALLATION AND OPERATING INSTRUCTIONS FOR CONCRETE VAULT TYPE UNITS CONTENTS Introduction Safety Operating Principle System Installation Initial Startup System Operations Troubleshooting Maintenance

More information

M-1115S Series Fuel Pump

M-1115S Series Fuel Pump SAVE THESE INSTRUCTIONS M-1115S Series Fuel Pump Owner s Manual TABLE OF CONTENTS General Information...2 Safety Instructions...2 Installation...3 Operation...4 Maintenance...5 Repair...5 Troubleshooting...9

More information

INSTALLATION INSTRUCTIONS FOR THE TRUCK MOUNTED VIPER ADDITIVE INJECTION SYSTEM GTP-8776C

INSTALLATION INSTRUCTIONS FOR THE TRUCK MOUNTED VIPER ADDITIVE INJECTION SYSTEM GTP-8776C INSTALLATION INSTRUCTIONS FOR THE TRUCK MOUNTED VIPER ADDITIVE INJECTION SYSTEM GTP-8776C This additive injection system was designed to be used with five gallon jug of additive. The system is supplied

More information

Low Pressure Transfer Systems

Low Pressure Transfer Systems Chapter 7b Low Pressure Transfer Systems Automotive Diesel Technology Understanding & Servicing Contemporary Clean Diesel Technology Gus Wright Low Pressure Transfer Layout of a low-pressure fuel transfer

More information

ENGINE COOLING GROUP CONTENTS RADIATOR GENERAL DESCRIPTION SPECIAL TOOLS THERMOSTAT

ENGINE COOLING GROUP CONTENTS RADIATOR GENERAL DESCRIPTION SPECIAL TOOLS THERMOSTAT 14-1 GROUP 14 CONTENTS GENERAL DESCRIPTION 14-2 SPECIAL TOOLS 14-3 DIAGNOSIS 14-3 INTRODUCTION 14-3 TROUBLESHOOTING STRATEGY 14-3 SYMPTOM CHART 14-4 SYMPTOM PROCEDURES 14-4 ON-VEHICLE SERVICE 14-17 ENGINE

More information

2010 MaxxForce 11 & 13 Fuel System Priming Tool Training for Technicians Study Guide

2010 MaxxForce 11 & 13 Fuel System Priming Tool Training for Technicians Study Guide TMT - 121307 Class Course Code: SD8361 January 2013 2010 MaxxForce 11 & 13 Fuel System Priming Tool Training for Technicians Study Guide 2010 MaxxForce 11 & 13 Fuel System Priming Tool Study Guide 2013

More information

Marine Filtration Systems

Marine Filtration Systems Marine Filtration Systems Table of Contents Troubleshooting Guide...3 Water Separation Efficiency...4 Turbine Series... 5-9 Diesel Spin-on Series... 10-11 Fuel Conditioning Module (P Series)... 12 Fuel

More information

Section: G Crankcase Filtration

Section: G Crankcase Filtration Section: Crankcase Filtration aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Table of Contents Closed Crankcase Ventilation

More information

Sea Pro FH240 Series Filter/Separator Installation Instructions

Sea Pro FH240 Series Filter/Separator Installation Instructions Sea Pro H240 Series ilter/separator Installation Instructions Sea Pro Single Short A B C D E Description Number A Top Nut Handle SP1288 B Nut Seal SP1287 C Service Cap SP1286 D Service Cap Seal SP1285

More information

Not required for most applications. Not required for most applications. High pressure ( provided) High pressure ( provided)

Not required for most applications. Not required for most applications. High pressure ( provided) High pressure ( provided) ELECTRIC FUEL PUMPS P/N 12-801-1, 712-801-1, 12-802-1, 12-802-2, 712-802-1, 12-812, 12-815-1, & 712-815-1 FUEL PRESSURE REGULATORS P/N 12-500, 12-501, 12-803, 12-803BP, 12-804, & 15812NOS Installation

More information

Total Area Sq. Pleat Height. Media area Difference % Racor % more. Wix

Total Area Sq. Pleat Height. Media area Difference % Racor % more. Wix Parker Hannifin Corporation Racor Division P.O. Box 3208, 3400 Finch Road Modesto, CA 95353 USA 800/344-3286, 209/521-7860 FAX 209/529-3278 Racor PF L2016 / 32007 Patent #6,086,763 / 6,554,139 B1 / 6,986,426,

More information

Automated Fuel Maintenance Systems (FPS)

Automated Fuel Maintenance Systems (FPS) FPS SERIES Automatic Alerts Pump Shut Down When Filters Need Service Leak Detection Water Detection High Pump Vacuum High Pump Pressure Compact Design Modular Controls Racor Filters Multi-stage Water Removal

More information

Installation Instructions

Installation Instructions Installation Instructions for 15912 to 15916 Electric Fuel Pumps & Fuel Pressure Regulators Installation Instructions WARNING! These instructions must be read and fully understood before beginning the

More information

Flow Max. by Duraself. Flow Max by Duraself. Fluid Pump. Installation and Owner s Manual (For Aftermarket Applications)

Flow Max. by Duraself. Flow Max by Duraself. Fluid Pump. Installation and Owner s Manual (For Aftermarket Applications) Flow Max Installation and Owner s Manual (For Aftermarket Applications) Table of Contents Introduction... 2 Parts List... 2 Resources Required... 3 Installation... 3 General Installation Instructions...

More information

Fueltec Models 950AW & 955SS Mobile Fuel Tank Cleaning Systems

Fueltec Models 950AW & 955SS Mobile Fuel Tank Cleaning Systems Fueltec Models 950AW & 955SS Mobile Fuel Tank Cleaning Systems Operation Manual Fueltec Systems LLC 828-212-1141 www.fueltecsystems.com FEATURES Stainless steel filter housings to resist the acids found

More information

ELECTRIC FUEL PUMPS P/N , , & FUEL PRESSURE REGULATOR P/N

ELECTRIC FUEL PUMPS P/N , , & FUEL PRESSURE REGULATOR P/N ELECTRIC FUEL PUMPS P/N 80000100, 80000101, & 80000102 FUEL PRESSURE REGULATOR P/N 80000103 Installation Instructions 199R10583 These instructions must be read and fully understood before beginning the

More information

BEFORE BEGINNING INSTALLATION

BEFORE BEGINNING INSTALLATION COMPLETE CHASSIS FUEL LINE KITS For 1996-2000 Honda Civic Equipped with B-Series Engine INSTALLATION INSTRUCTIONS PLEASE study these instructions carefully before beginning this installation. Most installations

More information

Crankcase Ventilation. Products and Custom Solutions

Crankcase Ventilation. Products and Custom Solutions Crankcase Ventilation Products and Custom Solutions Table of Contents Closed Crankcase Ventilation (CCV)...3-5 Market Challenges and Overview...3 Features and Benefits...4 Product Specifications...5 Open

More information

Marine Filtration Systems

Marine Filtration Systems Marine Filtration Systems Racor Filter Division Europe Car-In Automotive GmbH Daniel-Fahrenheit-Str. 4 48291 Telgte T: +49(0)2504 / 9 84 99-0 F: +49(0)2504 / 9 84 99-19 info@car-in-automotive.de www.car-in-automotive.de

More information

PO Box 645, Stockton, Missouri, FAX superiorgearbox.com W D0446-A 4/1/05 1

PO Box 645, Stockton, Missouri, FAX superiorgearbox.com W D0446-A 4/1/05 1 W000-7000-D0446-A 4/1/05 1 SAFETY PRECAUTIONS CAUTION Please read this entire document prior to operating the gear drive. Gear drive failure and / or injury to operators may be caused by improper installation,

More information

FUEL SYSTEM. Table of Contents. Specifications. Section 3A Fuel Delivery System. Models 6/8/9.9/10/15 CARBURETOR SPECIFICATIONS

FUEL SYSTEM. Table of Contents. Specifications. Section 3A Fuel Delivery System. Models 6/8/9.9/10/15 CARBURETOR SPECIFICATIONS FUEL SYSTEM Section 3A Fuel Delivery System Table of Contents Specifications............................. 3A-1 WMC Carburetor Specifications............. 3A-2 WMC Carburetor Specifications.............

More information

Instructions Parts List

Instructions Parts List Instructions Parts List ACETAL Husky 515 Air Operated Dual Inlet Diaphragm Pump Used to evacuate and transfer fluids. 100 psi (0.7 MPa, 7 bar) Maximum Fluid Working Pressure 100 psi (0.7 MPa, 7 bar) Maximum

More information

IFOA Integral Flow Orifice Assembly

IFOA Integral Flow Orifice Assembly Instruction MI 022-333 July 2007 Introduction IFOA Integral Flow Orifice Assembly The IFOA integral flow orifice assembly is used in conjunction with a Foxboro electronic or pneumatic differential pressure

More information

F76 Water Filters. Specifications. and MV876 Automatic-Backwash Control Accessory (not included)

F76 Water Filters. Specifications. and MV876 Automatic-Backwash Control Accessory (not included) F76 Water Filters and MV876 Automatic-Backwash Control Accessory (not included) The F76 is a high flow capacity water filter used to remove sediment and debris from residential or commercial water systems.

More information

6.7L Diesel Fuel Conditioning Module

6.7L Diesel Fuel Conditioning Module General Service Bulletin (GSB): This GSB references the inspection and bleed procedure for the 6.7L diesel low pressure fuel system. 6.7L Diesel Fuel Conditioning Module (DFCM) GSB Some 6.7L diesel vehicles

More information

PRO PRO20-115RD 115-Volt AC. PRO Volt AC OWNER'S MANUAL SAVE THESE INSTRUCTIONS

PRO PRO20-115RD 115-Volt AC. PRO Volt AC OWNER'S MANUAL SAVE THESE INSTRUCTIONS OWNER'S MANUAL SAVE THESE INSTRUCTIONS PRO20-115 PRO20-115RD 115-Volt AC PRO20-115AD Automatic Diesel Nozzle PRO20-115MD Manual Diesel Nozzle PRO20-115PO Pump Only PRO20-115RD For Remote Dispensing Systems

More information

45 VALVE SERIES. 2-Position 4-Way 5-Ports, Installation & Service Instructions. Valve with Stem Operator, Installation & Service Instructions

45 VALVE SERIES. 2-Position 4-Way 5-Ports, Installation & Service Instructions. Valve with Stem Operator, Installation & Service Instructions (02/20/8) Pneumatic Division Richland, Michigan USA www.parker.com/pneumatics Document Number V275CP V280CP V284CP V32CP 45 VALVE SERIES Description 3-Position 4-Way 5-Ports, Installation & Service Instructions

More information

WALKIE HIGH LIFT HYDRAULIC SYSTEM

WALKIE HIGH LIFT HYDRAULIC SYSTEM WALKIE HIGH LIFT HYDRAULIC SYSTEM W30-40ZA [B453]; W20-30ZR [B455]; W25-30-40ZC [B454] PART NO. 1524251 2000 SRM 1025 SAFETY PRECAUTIONS MAINTENANCE AND REPAIR When lifting parts or assemblies, make sure

More information

Industrial Pro FH239 Series Filter/Separator/Warmer Installation Instructions

Industrial Pro FH239 Series Filter/Separator/Warmer Installation Instructions Industrial Pro FH239 Series Filter/Separator/Warmer Installation Instructions K L Cover Industrial Pro Single Short H I W A B D F P C E J Bottom Bowl G Vent Cap Filter Element (includes part C) I R S T

More information

Model 100 Series Kits

Model 100 Series Kits Introductory Installation Information 1. Always install DAHL 100 on the vacuum (suction) side of transfer pump and ahead of any other filter: On domestic vehicles, remove the 3/8 inch I.D. hose from the

More information

Dual Fuel Filter Controller AND Fuel Polishing System GPH Fuel Flows Cleaner Fuel - Better Performance - Better Mileage

Dual Fuel Filter Controller AND Fuel Polishing System GPH Fuel Flows Cleaner Fuel - Better Performance - Better Mileage Don t leave shore without it Dual Fuel Filter Controller AND Fuel Polishing System 0-180 GPH Fuel Flows Cleaner Fuel - Better Performance - Better Mileage The BOSS COMMANDER system was designed to combat

More information

Fuel Filtration Systems

Fuel Filtration Systems Fuel Filtration Systems About Racor About Racor For nearly forty years, there has been one brand of fuel filtration systems that has earned the confidence and respect of engine and equipment builders,

More information

50 SERIES FILTER F50B Series F50B-04 pictured Application ANSI SYMBOL Primary air filters are designed to separate liquid, water, rust, pipe scale, an

50 SERIES FILTER F50B Series F50B-04 pictured Application ANSI SYMBOL Primary air filters are designed to separate liquid, water, rust, pipe scale, an FRL Products and Accessories High Flow FRL Series 50 Series Filters 44 50 Series Regulators 45 50 Series Pilot Operated Regulators 46 50 Series Lubricators 48 50 Series Filter/Regulator/Lubricator Combinations

More information