Nalco ACT Feed System and Accessories

Size: px
Start display at page:

Download "Nalco ACT Feed System and Accessories"

Transcription

1 Nalco ACT Feed System and Accessories Specification SPEC-478 Nalco ACT Feed System and accessories provide continuous feed of Advanced Condensate Treatment products to improve your boiler program s effectiveness. Uninterrupted feed of Nalco ACT is key to preventing acid and oxygen induced corrosion in condensate systems. Lower total system operating costs Maximize equipment reliability Minimize downtime and maintenance costs The Nalco Corrosion Monitor provides on-line assurance that your boiler system is optimized and protected using real time data. Hands-Free Delivery Nalco s certified delivery specialists are trained to handle Nalco ACT products safely in your plant. Our environmentally friendly PORTA-FEED delivery system eliminates the hassles and expense associated with the delivery of chemical in drums. Zero Defect Delivery Your inventory is managed to maximize the effectiveness of the Nalco ACT products in your process. Fresh product is especially important in food grade applications. Description Nalco ACT Advanced Condensate Treatment is a revolutionary condensate corrosion program that combines patented technology, state-of-the-art monitoring, field-proven equipment and Nalco s onsite service. The following information contained in this bulletin describes the key components required to obtain the best results from your Nalco ACT program. Nalco ACT Feed System Your inventory is managed to maximize the effectiveness of the Nalco ACT products in your process. A switchbox device (patent pending) ensures that you always have a continuous supply of fresh product available for your process. The Nalco ACT feed system comes with our PORTA-FEED unit complete with bag outlet valve assembly, four-way valve and bracket assembly and the switchbox assembly. These items are shipped assembled when you order a new PORTA-FEED base tank. The entire system is completely assembled to make your start-up quick and trouble-free. Your Nalco certified delivery specialist will make the final bag connection at the time of your first Nalco ACT feed system delivery.

2 Nalco ACT Chemical Feed Pump The Nalco ACT chemical feed pump, PULSAtron Series E Plus pump 0-3 gpd, 300 psi, comes with on/off controls. It includes a 5-function valve that has a built-in pressure relief and bleed valve to assist in priming the pump (Nalco Part Number 121-P ). Additional chemical metering pumps with higher capacity and increased pressure capability are available with an array of control features. Please contact your Nalco representative.in North America, you can also contact the Equipment Solutions Technical Support Group at Nalco ACT Chemical Injection Properly dispersing Nalco ACT in the boiler system is key to ensuring optimum performance. Use the Nalco retractable injector with a cut and slotted stinger and a check valve for each application point (Figure 1 on page 3). Some installations may require multiple application points to ensure complete system protection. The following two NALQUILL models are available: Part Number 231-P P Description NALQUILL retractable injector with cut and slotted 18-inch stinger. NALQUILL extended length retractable injector with cut and slotted 28-inch stinger. The retractable injectors allow you to inspect/clean the nozzle without shutting down the boiler. Choose the retractable injector that will allow you to introduce chemical feed into the center of the steam header. Keep in mind that you not only have to consider the pipe diameter but also the retractable injector must pass through the isolation assembly (typically pipe nipple, bushing and a 1-1/4 or larger gate valve not included with the injector.) Refer to Figure 2 for installation information. Selecting the Correct NALQUILL Retractable Injector Maximum Part Number Injector Size Insertion Length 231-P inches 7-1/2 inches 231-P inches 17-1/2 inches Size injector to position stinger in the center of the pipe. Total length of fittings (nipple, tee, gate, valve, coupling) plus 1/2 diameter of the pipe must be less than the maximum insertion length. Fittings are not included with NALQUILL injector. Example Pipe Diameter: 18 Nipple: 1 ea 1-1/4 diameter, 4 long Valve: 1 ea 2-1/2 long Tee: 1 ea 2 long Insertion length required = 1/2(18 ) + 1(4 ) + 1(2-1/2 ) + 1(2 ) = 17-1/2 The correct part would be 231-P with a 17-1/2 maximum insertion length. For installations (Figure 2) that do not permit Retractable Injectors use the following NALQUILL Injectors: Maximum Part Number Injector Size Insertion Length 231-P inches 3 inches 231-P inches 15 inches Refer to Figure 6 for installation. Nalco ACT Sample Conditioning To ensure accurate and reproducible results, sampling technique is critical. Be sure to use stainless steel sample lines and valves. Use a Nalco Sample Cooler (Part Number ) when sampling for metals or when temperatures/pressures exceed 350 F/1000 psi. 2

3 22 1/2" : 572 mm (D) 18" : 457 mm (A) 24 1/2" : 622 mm (C) 1" : 25 mm Safety collar 3 3/4" : 95 mm "Stinger" (E) 11 1/2" : 292 mm (B) 1/4" : 6 mm Note: Add 10" : 254 mm to dimensions A, C, and D for extended length injectors Figure 1 Nalco Retractable Injector with cut and slotted stinger Nalco ACT Monitor and Control Monitor the Nalco ACT program using the NCM100 for boilers (Part Number 400-NCM100KB.88). It s a good idea to establish a baseline corrosion rate prior to feeding the Nalco ACT products. An NCM100 Starter Kit for boilers internal data logger with real-time clock captures critical system information that allows you to trend system performance and provides assurance that your boiler system is under control. The Nalco Corrosion Monitor for boilers includes the corrosion monitor, software CD, manual, Smart high temperature probe (250 F/1000 psi maximum) with front and back ferrule, test probe, Swagelock fitting, 1018 MS probe tips (2), high temperature housing kit (tee and reducer) and a 6 foot serial cable. Use the optional WebAlert to monitor the performance of the Nalco ACT program at key points throughout your boiler system. Used along with the NCM100, you can log corrosion rates, trend the information in real time and obtain access from anywhere with your Internet web browser for up to six 4-20 ma isolated inputs. Set the userdefined alarms ( , page or short text message) to warn you about process upsets. Nalco ACT Product Dosage Dosage 5-15 ppm Dosage ppm Nalco ACT Nalco ACT Nalco ACT Nalco ACT FG Installation Guidelines Be sure to take a look at the typical installation diagrams (Figures 2, 3, 4, 5 and 6) prior to ordering or installing any equipment. Follow the recommendations to ensure the best program results. 3

4 To Order The PORTA-FEED Accessory Package for the Nalco ACT Feed System will be provided automatically when you place a base tank order for Nalco ACT products in container package code 37B. Order the required Nalco ACT Advanced Condensate accessories by using the Nalco part numbers listed below. Contact your local Nalco representative or our Nalco Customer Service at for further order information. Part Number Description Nalco ACT Metering Pump 121-P Nalco ACT Metering Pump Nalco Retractable Injector Select either the 18 or 28 injector: 231-P NALQUILL retractable injector with cut and slotted 18-inch stinger. 231-P NALQUILL extended length retractable injector with cut and slotted 28-inch stinger. Check valve 991-V Check valve (1 required per application point) check valve 304 SS 1/4 x 1/4 FNPT 25 psi Flexible Hose Teflon/304 SS Select one: 991-P braided hose Teflon/304 SS 1/4 inch MNPT Union 3000 psi, 450 F maximum 991-P braided hose Teflon/304 SS 1/2 inch MNPT Union 1500 psi, 450 F maximum NCM100 for boilers 400-NCM100KB.88 NCM100 for Boilers If you have a NCM100 for cooling water order the following parts for each sampling point to adapt to a boiler/condensate application. Part Number Description NCM100 Accessories (optional) 400-NCMP6.88 NCM boiler probe 400-NCMAC13.88 Boiler probe housing kit (tee and reducer) 400-NCMAC P P Boiler probe cable Boiler probe replacement tips (2 mild steel) Boiler probe Teflon O-rings Sample Cooler Sample cooler 316 SS 1 ft 2 (1 required per metals sampling point or if conditions exceed 350 F/1000 psi) WebAlert (optional) 051-WAEM WAEMN WebAlert with Ethernet and modem WebAlert with Ethernet, modem and networking master software. Accessories/ Replacement Parts Part Number Description 991-V Check valve 304 SS 1 4 in x 1 4 in FNPT 25 psi 420-C Millipore insoluble iron test kit 500-P Boiler probe replacement tips (2/pkg 1010 mild steel) 500-P Boiler probe Teflon O-rings 400-NCMP6.88 NCM boiler probe 400-NCMAC13.88 Boiler probe housing kit (tee and reducer) 400-NCMAC14.88 Boiler probe cable 231-ACT Nalco ACT delivery lance complete 231-ACT Nalco ACT delivery lance adapter 231-ACT Nalco ACT delivery lance disposable hose assembly 231-ACT Nalco ACT four-way valve and bracket assembly 231-ACT Nalco ACT bag outlet valve assembly 231-ACT Nalco ACT switchbox assembly 231-ACT Nalco ACT air relief valve assembly Nalco ACT four-way valve brass 1/4 inch 231-T Tubing polypropylene 1/4 inch 231-T Tubing polypropylene 3/8 inch Nalco ACT check valve brass 1/4 inch 231-P NALQUILL 6 - Fixed 231-P NALQUILL 18 - Fixed 4

5 DANGER Multiple feed points may be required to treat entire system. Locate 10 diameters downstream from sample points Cut tip facing flow Locate tip in center of pipe STEAM 1. Burn hazard 2. Pressurized equipment 3. Follow plant lock out and isolation procedures. 4. Wear appropriate personal protective equipment. 5. Safe access required for elevated installations. 6. Use Buddy System. Do not work alone. Steam header Vent valve Tee To process 1-1/4" or larger gate valve Nalco retractable injector Horizontal Flow Stainless steel flexible hose Isolation valve Protect from rain, direct sunlight Check valve To 45 acceptable radius To 120 acceptable radius Metal pipe Ball valve Pump 115 Vac, 15 Amps Level pad Boiler 1 Boiler 2 Boiler 3 Common Steam Header Retractable Injectors Process 1 Process 2 Process 3 Process 4 Process 5 Complicated boiler systems supplying multiple processes require individual Nalco ACT feed points to each process to ensure adequate protection. Figure 2 Nalco ACT installation setup 5

6 DANGER Steam From process STEAM 1. Burn hazard 2. Pressurized equipment 3. Follow plant lock out and isolation procedures. 4. Wear appropriate personal protective equipment. 5. Safe access required for elevated installations. 6. Use Buddy System. Do not work alone Locate sample tap off pipe bottom to minimize contamination 1/2" SS gate valve 1/4" SS sample line Cooling water out 5.0 Corrosion rate, mpy Neutralizing amine treatment No treatment Nalco ACT corrosion inhibitor Nalco ACT interrupted Gate valve Sample cooler required for metal studies or when temperature/pressure exceeds, 350 F/1000 psi Sep 16-Sep 26-Sep 6-Oct 16-Oct Throttle outlet only To drain Date Internet Cooling water in Remote monitoring Real-time data s Datalogs Alarm Notification NCM100 Flush connection for cleaning For accurate, reproducible test results: Sample cooled to less than 75 F Continuous flow Metals analysis requires 5-6 ft/sec flow velocity (2 gpm in 1/4" schedule 40 pipe) Dry contact alarm relay RS 232 Local monitoring Corrosion rate (4-20mA input) High temperature probe 350 F, 1000 psi max Block valve To drain Vent/depressurize line before removing probe Figure 3 Nalco ACT Monitoring and Control Primary sample location 1/2" SS gate valve Condensate receiver tank Pump 1/4" SS sample line Cooling water out Secondary sample location Gate valve Sample cooler required for metal studies or when temperature/pressure exceeds 350 F/1000 psi Throttle outlet only To drain Cooled sample To NCM100 Cooling water in Flush connection for cleaning Figure 4 Alternate sampling points 6

7 Figure 5 Nalco ACT feed system general arrangement Pipe coupling Pipe nipple Weld CL 1 1/2" A.P.I. pipe Support If you have any questions regarding this specification, please contact your local Nalco representative. In North America, you can also contact the Equipment Solutions Technical Support Group at /16" 6" A.P.I. pipe Weld coupling CL 3 9/16" Figure 6 Fixed NALQUILL installation, used when retractable injector installations are not permitted NALCO COMPANY OPERATIONS North America: 1601 West Diehl Road Naperville, Illinois USA Europe: Ir.G.Tjalmaweg BV Oegstgeest The Netherlands Asia Pacific: 2 International Business Park #02-20 The Strategy Tower 2 Singapore Latin America: Av. das Nações Unidas Andar São Paulo SP Brazil NALQUILL, PORTA-FEED, Nalco ACT, Zero Defect Delivery NALCO and the logo are Registered Trademarks of Nalco Company WebAlert is a Trademark of Walchem Corporation 2004, 2007 Nalco Company All Rights Reserved 12-07

Nalco Corrosion Test Rack 1

Nalco Corrosion Test Rack 1 Corrosion Test Racks 500-C0191.88, 500-C0192.88 Analytical Procedure SPECIFICATIONS, Nalco Corrosion Test Rack 1, 500-C0192.88, Nalco Clear View Corrosion Test Rack, 500-C0191.88 Assembled size: 24 in.

More information

25198:- 1/31/12 11:24 AM Page 2 Filtration Systems

25198:- 1/31/12 11:24 AM Page 2 Filtration Systems Filtration Systems Indufil Filtration Systems Global Leadership in Design Expertise and Technical Support From its origins more than 95 years ago, John Crane has become a world leader in the design, development

More information

Polymer Makedown Systems

Polymer Makedown Systems Polymer Makedown Systems Pulsafeeder Expertise Technology is the key to delivering responsible products to the markets that we serve. Leading the way in the development of metering technologies, Pulsafeeder

More information

3D TRASAR Automation - Boiler Blowdown Equipment

3D TRASAR Automation - Boiler Blowdown Equipment 3D TRASAR Automation - Boiler Blowdown Equipment Reduces water and fuel costs by eliminating excessive blowdown Provides better program control and boiler reliability by maintaining boiler TDS at the optimum

More information

An IDEX Water & Wastewater Business. pulsafeeder.com. Boiler. Programmable Boiler Controller

An IDEX Water & Wastewater Business. pulsafeeder.com. Boiler. Programmable Boiler Controller An IDEX Water & Wastewater Business pulsafeeder.com Boiler Programmable Boiler Controller Pulsafeeder Expertise Technology is the key to delivering responsible products to the markets that we serve. Leading

More information

STEAM TURBINE BY-PASS AND STEAM CONDITIONING VALVE

STEAM TURBINE BY-PASS AND STEAM CONDITIONING VALVE STEAM TURBINE BY-PASS AND STEAM CONDITIONING VALVE Benefits Savings of up to US$ 200.000 per year in maintenance costs Production gains due to superior stability of the temperature control Operational

More information

Model 6330 COSASCO Retractable System Injection/Sampling Tube Assemblies

Model 6330 COSASCO Retractable System Injection/Sampling Tube Assemblies Model 6330 COSASCO Retractable System Injection/Sampling Tube Assemblies Order Length A Dimension Inches mm 18 24.54 623 24 30.54 775 30 36.54 928 36 42.54 1080 Specifications: Pressure Rating 1500 PSI

More information

Analog Condensate Monitor Instruction & Maintenance Manual

Analog Condensate Monitor Instruction & Maintenance Manual Analog Condensate Monitor Instruction & Maintenance Manual Advantage Controls, Inc. PO Box 1472 Muskogee, OK 64402 Phone: 800-743-7431 Fax: 888-686-6212 www.advantagecontrols.com EE-13 email: aci@advantagecontrols.com

More information

S v S e r i e s F M f i r e e x t i n g u i s h i n g s y s t e m

S v S e r i e s F M f i r e e x t i n g u i s h i n g s y s t e m Clean S v S e r i e s F M - 2 0 0 f i r e e x t i n g u i s h i n g s y s t e m Advantages The Sv Series Clean Agent Fire Extinguishing System utilizes FM-200 as the extinguishing medium. FM-200 is a colorless,

More information

Please note this is a condensed catalog. For a complete version, contact Velan directly.

Please note this is a condensed catalog. For a complete version, contact Velan directly. Please note this is a condensed catalog. For a complete version, contact Velan directly. VELAN VALVES IN POWER With an installed base covering over 300 nuclear power plants and over 2,000 thermal power

More information

HOT TAPPING & PLUGGING SOLUTIONS

HOT TAPPING & PLUGGING SOLUTIONS HOT TAPPING & PLUGGING SOLUTIONS STOPPLE Plus System Combined with a LOCK-O-RING Plus completion plug, the STOPPLE Plus fitting reduces installation time, simplifies the setting process, and eliminates

More information

Portable Liquid Pump and Filter Systems Compressed Air-Powered Pump and Filter System

Portable Liquid Pump and Filter Systems Compressed Air-Powered Pump and Filter System Portable Liquid Pump and Filter Systems Compressed Air-Powered Pump and Filter System Technical Bulletin C PORTABLE LIQUID PUMP AND FILTER SYSTEMS DESCRIPTION Filtration Systems Portable Liquid Pump &

More information

Water treatment services product catalog

Water treatment services product catalog Water treatment services product catalog custom work Sample cooler Sample coolers are a safe method of withdrawing water from boilers, steam lines or tanks containing chemicals and for cooling the withdrawn

More information

65 Series. Valve Operation Manual

65 Series. Valve Operation Manual 65 Series Valve Operation Manual Note: 1. Read all instructions carefully before operation. 2. Avoid pinched o-rings during installation by applying (provided with install kit) NSF certified lubricant

More information

BOILER BLOWDOWN CONDUCTIVITY CONTROLLER (CONTINUOUS METHOD)

BOILER BLOWDOWN CONDUCTIVITY CONTROLLER (CONTINUOUS METHOD) LAKEWOOD INSTRUMENTS MODEL 260 SERIES BOILER BLOWDOWN CONDUCTIVITY CONTROLLER (CONTINUOUS METHOD) INSTALLATION & OPERATION MANUAL SERIAL #: Lakewood Instruments 7838 North Faulkner Road, Milwaukee, WI

More information

Manual. Economy Glycol Feeder. Installation Maintenance Repair Manual

Manual. Economy Glycol Feeder. Installation Maintenance Repair Manual Manual Economy Glycol Feeder Installation Maintenance Repair Manual Advantage Controls P.O. Box 1472 Muskogee, OK 74402 Phone: 800-743-7431 Fax: 888-686-6212 www.advantagecontrols.com email: support@advantagecontrols.com

More information

Injection/Sample Quills

Injection/Sample Quills Injection/Sample Quills Retractable injection quills are devices that deliver chemicals to a desired location inside piping. Generally, quills are used when relatively small amounts of chemicals are being

More information

PARTS LIST FOR WLP-40-0M10 WATER RECYCLING TREATMENT SYSTEM

PARTS LIST FOR WLP-40-0M10 WATER RECYCLING TREATMENT SYSTEM PARTS LIST FOR WLP-40-0M10 WATER RECYCLING TREATMENT SYSTEM Copyright 2006, Mi-T-M Corporation 1 Congratulations on the purchase of your new Mi-T-M water treatment system! This parts listing has been complied

More information

Flue Gas Analyzer IMR 1100F

Flue Gas Analyzer IMR 1100F Flue Gas Analyzer IMR Environmental Equipment. Inc. 3634 Central Ave. St. Petersburg Florida 33711 Tel: 727-328-2818 Fax 727-328-2826 info@imrusa.com www.imrusa.com User Manual INTRODUCTION 3 SAFETY INSTRUCTIONS

More information

Aeroflow SCV Steam Control Steam Conditioning Turbine Bypass Valve

Aeroflow SCV Steam Control Steam Conditioning Turbine Bypass Valve Aeroflow SCV Steam Control Steam Conditioning Turbine Bypass Valve High Performance in a Competitive Package ZERO Leak Technology Non-Binding Trim Design Quick, Easy Maintenance 5/1 Version 3 Product Information

More information

Section 3 Technical Information

Section 3 Technical Information Section 3 Technical Information In this Module: Engine identification Modes of operation Battery charging and heat manage operation Service and repair procedures Maintenance requirements Engine Identification

More information

INSTRUCTIONS AND PARTS LIST FOR MODEL FORCE 10DA and FORCE 25DA (Double Acting, Electrically-Operated Hydraulic Press)

INSTRUCTIONS AND PARTS LIST FOR MODEL FORCE 10DA and FORCE 25DA (Double Acting, Electrically-Operated Hydraulic Press) INSTRUCTIONS AND PARTS LIST FOR MODEL FORCE 10DA and FORCE 25DA (Double Acting, Electrically-Operated Hydraulic Press) Operation 1. Plug power cord into a 115-volt A.C. single phase 60-cycle grounded,

More information

ONYX VALVE. Pressure Isolator Ring. New Patented Design Assures Accuracy and Maintenance-Free Operation Patent #5,708,201

ONYX VALVE. Pressure Isolator Ring. New Patented Design Assures Accuracy and Maintenance-Free Operation Patent #5,708,201 ONYX VALVE Pressure Isolator Ring New Patented Design Assures Accuracy and Maintenance-Free Operation Patent #5,708,201 The Onyx Isolator Ring Outperforms Conventional Isolator Rings and Standard Diaphragm

More information

Mild Steel Dosing Pots

Mild Steel Dosing Pots Mild Steel Dosing Pots Data Sheet Features Introduction Materials of Construction Most heating and chilled water systems require chemical dosing and the BOSS range of Dosing Pots provides a controlled

More information

#9040 FUEL TANK SWEEPER

#9040 FUEL TANK SWEEPER #9040 FUEL TANK SWEEPER INSTRUCTION MANUAL FILTERS AND REMOVES FINE BIO-CONTAMINANTS, ALGAE, ETC. SWEEPING PROCESS REMOVES LARGE CONTAMINANTS FROM OIL TANKS SUCH AS RUST, WATER, CRUDE AND DIRT CIRCULATES

More information

Workplace Safety and Health Practices Award:

Workplace Safety and Health Practices Award: Workplace Safety and Health Practices Award: Workplace Safety & Health Awards 2007 Chemical / Ergonomics / Safety Nalco Pacific Pte Ltd Semi Automatic Liquid Product Filling System Presenter: Saifuddin

More information

SP Series - Fiberglass Epoxy Integral Joint Surface Pipe

SP Series - Fiberglass Epoxy Integral Joint Surface Pipe SP Series - Fiberglass Epoxy Integral Joint Surface Pipe Applications Flow Lines Injection Lines Gas Gathering & Transport Lines Recirculating Lines Solution Mining Water Processing Joining System Features

More information

Series 774 Automatic Skid Package

Series 774 Automatic Skid Package Fluid Engineering 1432 Walnut St Erie, PA 16502 USA PH 814.453.5014 FAX 814.452.6573 www.fluideng.com sales @fluideng.com CONTINUOUS FLOW The Fluid Engineering 774 Strainer Package is designed to handle

More information

BNT 85 /185 Valve Operation Manual

BNT 85 /185 Valve Operation Manual BNT 85 /185 Valve Operation Manual Note: 1. Read all instructions carefully before operation. 2. Avoid pinched o-rings during installation by applying (provided with install kit) NSF certified lubricant

More information

Regenerative Turbine Pumps

Regenerative Turbine Pumps Bulletin 0 0 2 0 2 170 270 Series Regenerative Turbine Pumps Capacities to 0 GPM Heads to Feet MTH PUMPS 0 2 0 2 170 270 Series Regenerative Turbine Pump MTH 0 2 0 2 170 270 Series regenerative turbine

More information

Electronic Metering Pump

Electronic Metering Pump Electronic Metering Pump Pressure (PSI) Pressure (BAR) Pulsafeeder Expertise Technology is the key to delivering responsible products to the markets that we serve. Leading the way in the development of

More information

Verifiable and Zero Leakage Design. PosiWell Pte Ltd. No. 9A Joo Koon Crescent Singapore Registration No N. Innovation By Design

Verifiable and Zero Leakage Design. PosiWell Pte Ltd. No. 9A Joo Koon Crescent Singapore Registration No N. Innovation By Design Verifiable and Zero Leakage Design PosiWell Pte Ltd Asia Pacific Regions Europe / USA Regions No. 9A Joo Koon Crescent Singapore 629023 Registration No. 201221185N Alfred Tan Leon Niessen PosiWell patented

More information

Remote Monitoring System

Remote Monitoring System Specification Sheet PowerCommand Cloud Remote Monitoring System Power Generation Telematics Description The PowerCommand Cloud is a robust and reliable remote monitoring system that provides information

More information

Installation and Operation Manual

Installation and Operation Manual Installation and Operation Manual SENTINEL Back Pressure Valves SENTINEL Pressure Relief Valves SENTINEL Calibration Columns BLACOH Fluid Control 601 Columbia Ave, Bldg D Riverside, CA 92507 USA Phone:

More information

IWT 565 Series Valve Operation Manual

IWT 565 Series Valve Operation Manual IWT 565 Series Valve Operation Manual Note: 1. Read all instructions carefully before operation. 2. Avoid pinched o-rings during installation by applying (provided with install kit) NSF certified lubricant

More information

LEAD FREE * LFF113RFP Flood Protection Shut Down Valve

LEAD FREE * LFF113RFP Flood Protection Shut Down Valve Technical Bulletin TB-ACV-LFF11RFP LEAD FREE * LFF11RFP Flood Protection Shut Down Valve Installed upstream of Reduced Zone Backflow Preventer. Normally Open Valve - Closes when continuous discharge from

More information

M High Performance Power Transmission Couplings

M High Performance Power Transmission Couplings Engineered for Powerful Performance M High Performance Power Transmission Couplings Metastream High Performance Power Transmission Couplings High Performance Technology Metastream power transmission couplings

More information

Controller Specification Sheet

Controller Specification Sheet Controller Specification Sheet MC9320AXXXBX Proportional Inhibitor Dosing, Conductivity Bleed Control, Redox Control of Oxidising Biocide and Secondary Biocide Dosing PULSAtrol Controllers are microprocessor

More information

Technical Data TYPE A SERIES AIR ADJUSTED PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4011 OPERATING PRINCIPLE

Technical Data TYPE A SERIES AIR ADJUSTED PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4011 OPERATING PRINCIPLE Technical Data SD 4011 SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY 12586-2035 TYPE A SERIES AIR ADJUSTED PILOT PRINTED IN U.S.A. SD 4011/9504 Type A or A83 (wt 6 lb) Type A53 or A 85

More information

CW-2004-SME3: PARTS LIST FOR (AFTER SERIAL # ) Motor Horsepower: Pump Oil Capacity: Nozzle Size: CW-2004-SME3: 5.5

CW-2004-SME3: PARTS LIST FOR (AFTER SERIAL # ) Motor Horsepower: Pump Oil Capacity: Nozzle Size: CW-2004-SME3: 5.5 PARTS LIST FOR CW-2004-SME3 (AFTER SERIAL #10375000) Motor Horsepower: CW-2004-SME3: 6.0 H.P. Pump Oil Grade: Mi-T-M Pump Oil #AW-4085-0016 Pump Oil Capacity: 41 oz. Nozzle Size: CW-2004-SME3: 5.5 This

More information

744A SprAyer Control U S e r M A n U A l

744A SprAyer Control U S e r M A n U A l 744A Sprayer Control User MANUAL Table of Contents Product Chapter 1 - Introduction 2 System Configurations... 2 Kit Contents... 4 Control Housing Assembly... 6 Chapter 2 - Installation 7 Mounting Bracket...

More information

Multiport Flow Selector. Compact And Economical Production Test Manifold

Multiport Flow Selector. Compact And Economical Production Test Manifold Multiport Flow Selector Compact And Economical Production Test Manifold Design and Construction Emerson Process Management Valve Automation provides a broad product offering of automation and control solutions

More information

Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount

Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount Important Safety Messages Read the instructions carefully to become familiar with the equipment before attempting to install, operate,

More information

Plumbing. Controls, Drains, Piping, Flanges, Couplings, Caps and Plugs

Plumbing. Controls, Drains, Piping, Flanges, Couplings, Caps and Plugs Plumbing Hale offers a wide variety of plumbing components to make the pump installation and operation easier for the OEM and End User. Hale controls allow for a clean and compact pump panel. Controls

More information

WALCHEM LINEAR POLARIZATION RESISTANCE CORROSION SENSORS Instruction Manual

WALCHEM LINEAR POLARIZATION RESISTANCE CORROSION SENSORS Instruction Manual WALCHEM LINEAR POLARIZATION RESISTANCE CORROSION SENSORS Instruction Manual 1 Notice 2018 WALCHEM, Iwaki America Inc. (hereinafter Walchem ) 5 Boynton Road, Holliston, MA 01746 USA (508) 429-1110 All Rights

More information

MEASUREMENT SOLUTIONS FOR THE WATER & WASTEWATER INDUSTRY

MEASUREMENT SOLUTIONS FOR THE WATER & WASTEWATER INDUSTRY MEASUREMENT SOLUTIONS FOR THE WATER & WASTEWATER INDUSTRY MUNICIPAL AND INDUSTRIAL WATER & WASTEWATER PROCESSING NOSHOK provides pressure, level and temperature measurement solutions, along with diaphragm

More information

Enhanced Vapor Recovery and In-Station Diagnostics. Presented by: Matthew Schuessler, N Cal Territory Mgr 1

Enhanced Vapor Recovery and In-Station Diagnostics. Presented by: Matthew Schuessler, N Cal Territory Mgr 1 Enhanced Vapor Recovery and In-Station Diagnostics Presented by: Matthew Schuessler, N Cal Territory Mgr 1 The Healy EVR Phase II Vac-Assist solution Based on the August 1999 CARB ORVR certified Healy

More information

Pump Division MSP. Vertical, In-line, Medium Speed Pump. Bulletin PS-10-1c (E/A4)

Pump Division MSP. Vertical, In-line, Medium Speed Pump. Bulletin PS-10-1c (E/A4) MSP Vertical, In-line, Medium Speed Pump Bulletin PS-10-1c (E/A4) Pump Supplier To The World Flowserve is the driving force in the global industrial pump marketplace. No other pump company in the world

More information

Model T25 Triplex Power Pump

Model T25 Triplex Power Pump weatherford Model t25 triplex power pump Model T25 Triplex Power Pump Pump and Fluid Systems Weatherford s Model T25 is a single-acting, triplex plunger pump rated at 23 HP in continuous duty service and

More information

True Fail-Safe Technology and Precision Control for Reliable Shutdown

True Fail-Safe Technology and Precision Control for Reliable Shutdown True Fail-Safe Technology and Precision Control for Reliable Shutdown RTS Series Compact Fail-Safe Electric Actuators Reliable, Accurate, Compact Electric Actuation Technology for Critical Fail-Safe and

More information

Direct contact, metal-to-metal seating, make the gate valve ideal for most shutoff applications. Class 800 ANSI.

Direct contact, metal-to-metal seating, make the gate valve ideal for most shutoff applications. Class 800 ANSI. Direct contact, metal-to-metal seating, make the gate valve ideal for most shutoff applications. Class 800 ANSI. Features Two inch and smaller valves are available with threaded or socket weld ends as

More information

GLYCOL FEED SYSTEMS OPERATION & MAINTENANCE MANUAL

GLYCOL FEED SYSTEMS OPERATION & MAINTENANCE MANUAL GLYCOL FEED SYSTEMS OPERATION & MAINTENANCE MANUAL PLEASE RECORD THE FOLLOWING DATA (Information is located on the product label or packing slip) Model Number: Date Code: Installation Date: Installation

More information

YARWAY HANCOCK Y-PATTERN FORGED STEEL GLOBE STOP VALVES SERIES 4000

YARWAY HANCOCK Y-PATTERN FORGED STEEL GLOBE STOP VALVES SERIES 4000 Direct contact and metal-to-metal seating make this Y-pattern globe stop valve ideal for most shut-off applications. FEATURES All valves feature integral Stellite hardfacing on both body and disc seating

More information

SERVICE MANUAL / PARTS LIST MODEL XSG-5

SERVICE MANUAL / PARTS LIST MODEL XSG-5 ation SERVICE MANUAL / PARTS LIST MODEL XSG-5 1055 Mendell Davis Drive Jackson MS 39272 888-994-7636 601-372-3903 Fax 888-864-7636 unifiedbrands.net PART NUMBER 158634 REV B (11/11) TABLE OF CONTENTS 2

More information

Low Pressure Series - Accessories. High Pressure Series - Accessories

Low Pressure Series - Accessories. High Pressure Series - Accessories Low Pressure Series - Accessories STCO 50 Low Pressure Variable Spray Gun - Bronze Max. Pressure: 0Bar(50PSI) Inlet: /2 FBSP Max. Flow: 6GPM(23Lt/Min) 60 C(40 F) STCO 50-SS Low Pressure Variable Spray

More information

MODEL 106/206-PG POWER OPERATED GLOBE VALVE Sizes 1/2" to 8" (106-PG) 3" to 10" (206-PG) Installation, Operating and Maintenance Instructions

MODEL 106/206-PG POWER OPERATED GLOBE VALVE Sizes 1/2 to 8 (106-PG) 3 to 10 (206-PG) Installation, Operating and Maintenance Instructions MODEL 106/206-PG POWER OPERATED GLOBE VALVE Sizes 1/2" to 8" (106-PG) 3" to 10" (206-PG) Installation, Operating and Maintenance Instructions DESCRIPTION: This valve is the basic component used for most

More information

Pump Division HDX. API 610 Double Suction, Radially Split Process Pump. Bulletin PS-20-4 (E/A4)

Pump Division HDX. API 610 Double Suction, Radially Split Process Pump. Bulletin PS-20-4 (E/A4) HDX API 610 Double Suction, Radially Split Process Pump Bulletin PS--4 (E/A4) Pump Supplier To The World Flowserve is the driving force in the global industrial pump marketplace. No other pump company

More information

Pump Division HDX. API 610 Radially Split, Double Suction Process Pump. Bulletin PS-20-4a (E)

Pump Division HDX. API 610 Radially Split, Double Suction Process Pump. Bulletin PS-20-4a (E) HDX API 610 Radially Split, Double Suction Process Pump Bulletin PS--4a (E) Pump Supplier To The World Flowserve is the driving force in the global industrial pump marketplace. No other pump company in

More information

BRAVER UPS. (Uninterruptible Power System) User s Manual

BRAVER UPS. (Uninterruptible Power System) User s Manual BRAVER UPS (Uninterruptible Power System) User s Manual Safety CAUTION! This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user replaceable parts.

More information

NC State University Design and Construction Guidelines Division 23 Energy Management

NC State University Design and Construction Guidelines Division 23 Energy Management 1.1 Purpose A. The following guidelines provide the methodology and requirements to assure that designs meet NC State standards for campus utility metering. 2.1 General Requirements A. Meters shall have

More information

T & M Series Couplings. Metal membrane couplings for the oil & gas industry

T & M Series Couplings. Metal membrane couplings for the oil & gas industry T & M Series Couplings Metal membrane couplings for the oil & gas industry From design stage through to plant management Metastream couplings have for over 40 years been operating successfully in the oil

More information

-5 F to 620 F. High Performance, Low-pressure Heat Transfer Fluid. Heat Transfer Fluid by Solutia. Technical Bulletin A +400 C +700 F +350 C

-5 F to 620 F. High Performance, Low-pressure Heat Transfer Fluid. Heat Transfer Fluid by Solutia. Technical Bulletin A +400 C +700 F +350 C 62 High Performance, Low-pressure Heat Transfer Fluid Heat Transfer Fluid by Solutia Technical Bulletin 7239731A 62-5 F to 620 F +400 C +350 C +300 C +250 C +200 C +150 C +100 C +50 C 0 C +700 F +600 F

More information

PumpWorks HP-Plus HORIZONTAL HIGH PRESSURE MULTI-STAGE PUMP

PumpWorks HP-Plus HORIZONTAL HIGH PRESSURE MULTI-STAGE PUMP PumpWorks HP-Plus HORIZONTAL HIGH PRESSURE MULTI-STAGE PUMP PumpWorks HP-Plus APPLICATIONS Amine Fluid Transfer Gas Processing Mine Dewatering Pipeline Booster Saltwater Disposal Water Injection Water

More information

Cartridge Filter Housings Nowata A Series

Cartridge Filter Housings Nowata A Series Cartridge Filter Housings Nowata A Series Customization May Change the Model Number Designation to B, D or F Series 1. Introduction All A series cartridge filter housings are designed for efficient liquid

More information

BULLETIN August 2009 PERMASEAL PLUG VALVE. ISO 9001:2008 Certified QMS. SMG Valves A Unit of Southern Manufacturing Group, Inc.

BULLETIN August 2009 PERMASEAL PLUG VALVE. ISO 9001:2008 Certified QMS. SMG Valves A Unit of Southern Manufacturing Group, Inc. BULLETIN 13.01-01 August 2009 PERMASEAL ISO 9001:2008 Certified QMS SMG Valves A Unit of Southern Manufacturing Group, Inc. Design and Construction Permaseal Plug Valves are designed for on-off and diverting

More information

USER MANUAL. Blazer Vista 1000/1400/2000. Uninterruptible Power System

USER MANUAL. Blazer Vista 1000/1400/2000. Uninterruptible Power System USER MANUAL Blazer Vista 1000/1400/2000 Uninterruptible Power System IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions for model Blazer Vista 1000/1400/2000

More information

CONTACTING CONDUCTIVITY GENERAL PURPOSE SENSORS Instruction Manual

CONTACTING CONDUCTIVITY GENERAL PURPOSE SENSORS Instruction Manual CONTACTING CONDUCTIVITY GENERAL PURPOSE SENSORS Instruction Manual Notice 2018 WALCHEM, Iwaki America Inc. (hereinafter Walchem ) 5 Boynton Road, Holliston, MA 01746 USA (508) 429-1110 All Rights Reserved

More information

OMNI Brochure 11/9/04 9:56 AM Page 3

OMNI Brochure 11/9/04 9:56 AM Page 3 OMNI Brochure 11/9/04 9:6 AM Page 3 OMNI Brochure 11/9/04 9:6 AM Page 4 Pulsafeeder Technology Pulsafeeder, the global leader in liquid chemical feed innovation, continues to bring new technology into

More information

Electrical Installation

Electrical Installation Electrical Installation Symmetra LX Tower UPS Models 200 V, 4-8 kva 208/240 V, 4-8 kva 220/230/240 V, 4-8 kva 200 V, 4-16 kva 208/240 V, 4-16 kva 220/230/240 V, 4-16 kva Important Safety Messages SAVE

More information

An IDEX Water & Wastewater Business. pulsafeeder.com. Electronic Metering Pump

An IDEX Water & Wastewater Business. pulsafeeder.com. Electronic Metering Pump An IDEX Water & Wastewater Business pulsafeeder.com Electronic Metering Pump Pressure (PSI) Pressure (BAR) Pulsafeeder Expertise Technology is the key to delivering responsible products to the markets

More information

AQUASTAR C6. (Comfort 6000) Next Generation Auto Backwash Valve System. (selectable time-pressure or remote cycle start)

AQUASTAR C6. (Comfort 6000) Next Generation Auto Backwash Valve System. (selectable time-pressure or remote cycle start) AQUASTAR C6 (Comfort 6000) Next Generation Auto Backwash Valve System (selectable time-pressure or remote cycle start) SIDE MOUNTED AND TOP MOUNTED VALVES WITH QUICK INSTALL ELECTRIC ACTUATORS FOR PIPE

More information

Installation Instructions

Installation Instructions Installation Instructions Seal Gard Flowmeter TM Unitized construction Plug resistant float design Tamper resistant valve design Pressure gauge standard Check valve standard 0-20 gph or 0-40 gph standard

More information

Customized ELECTRO-HYDRAULIC CONTROL SYSTEM

Customized ELECTRO-HYDRAULIC CONTROL SYSTEM Customized ELECTRO-HYDRAULIC CONTROL SYSTEM ELECTRO-HYDRAULIC CONTROL SYSTEM 2 Since the founding of Automation Technology (ATI) more than 20 years ago, we have been recognized for innovation and dependability

More information

Sola/Hevi-Duty S3K Series Mini-Tower UPS

Sola/Hevi-Duty S3K Series Mini-Tower UPS Sola/Hevi-Duty S3K Series Mini-Tower UPS GUIDE SPECIFICATIONS 700VA to 1600VA 120V models Single - Phase Uninterruptible Power Supply Systems 1.1 SUMMARY 1.0 GENERAL This specification defines the electrical

More information

True Fail-Safe Technology and Precision Control Meet Emergency Shutdown and Demanding Process Applications

True Fail-Safe Technology and Precision Control Meet Emergency Shutdown and Demanding Process Applications True Fail-Safe Technology and Precision Control Meet Emergency Shutdown and Demanding Process Applications RTS Series Compact Fail-Safe Electric Actuators Reliable, Accurate, Compact Electric Actuation

More information

Operating Instructions ProMinent. Backpressure and Pressure Relief Valves

Operating Instructions ProMinent. Backpressure and Pressure Relief Valves Operating Instructions and Valves Contents Page Safety Instructions... 2 Unpacking... 2 Introduction... 2 Installation... 3 Description of Controls & Operation... 5 Helpful Tips... 5 Specifications...

More information

Service Manual. 854E Diesel Engine. Specifications. 854E model is for FD70N Chassis Service Manual B101

Service Manual. 854E Diesel Engine. Specifications. 854E model is for FD70N Chassis Service Manual B101 Service Manual 854E Diesel Engine Specifications 854E model is for FD70N Chassis Service Manual. 99709-5B101 FOREWORD This service manual describes the specifications, maintenance, and service procedures

More information

PowerCommand 500/550 Remote Monitoring System

PowerCommand 500/550 Remote Monitoring System PowerCommand 500/550 Remote Monitoring System Complete remote monitoring of your power system The PowerCommand 500 series provides a convenient means of remotely monitoring generator sets, transfer switches,

More information

P844L3MS For Models: NL844L3.1MS1 and NL844L3.1MS2 PARTS CATALOG. Marine Generators Marine Diesel Engines Land-Based Generators

P844L3MS For Models: NL844L3.1MS1 and NL844L3.1MS2 PARTS CATALOG. Marine Generators Marine Diesel Engines Land-Based Generators P844L3MS For Models: NL844L3.1MS1 and NL844L3.1MS2 PARTS CATALOG Marine Generators Marine Diesel Engines Land-Based Generators CALIFORNIA Proposition 65 Warning: Diesel engine exhaust and some of its constituents

More information

Type 644 and 645 Differential Pressure Pump Governors

Type 644 and 645 Differential Pressure Pump Governors Instruction Manual 644 and 645 Pump Governors Type 644 and 645 Differential Pressure Pump Governors Introduction Scope of Manual This instruction manual provides information on installation, adjustment,

More information

Instrumentation Products Overview. Flow Control

Instrumentation Products Overview. Flow Control Instrumentation Products Overview Flow Control World Leading Instrument Valve Solutions Century Valve is the number one choice for Instrument Valves and Manifolds; number one for range of products and

More information

THERMINOL 66. heat transfer fluid. Proven performance for high-temperature, low-pressure applications. -3 to 345 C. (27 to 650 F)

THERMINOL 66. heat transfer fluid. Proven performance for high-temperature, low-pressure applications. -3 to 345 C. (27 to 650 F) THERMINOL 66 heat transfer fluid Proven performance for high-temperature, low-pressure applications -3 to 345 C (27 to 650 F) THERMINOL 66 heat transfer fluid Min. use temp., 27 Max. bulk use temp., 650

More information

GTD-Series. Direct Gas Actuators

GTD-Series. Direct Gas Actuators GTD-Series Direct Gas Actuators GTD-Series Direct Gas Actuators Enclosed Cast Housing Bearings Xylan Coated Internals Piston Seals Travel Stop Vent Check NAMUR Acculine Shaft Drive Features and Benefits

More information

Manual. Series 2EZ. Installation Maintenance Repair Manual

Manual. Series 2EZ. Installation Maintenance Repair Manual Manual Series 2EZ Installation Maintenance Repair Manual Advantage Controls P.O. Box 1472 Muskogee, OK 74402 Phone: 800-743-7431 Fax: 888-686-6212 www.advantagecontrols.com email: support@advantagecontrols.com

More information

The Right Tool for Your Tough Job

The Right Tool for Your Tough Job SULLAIR air tools The Right Tool for Your Tough Job Applications Tool Sullair Model Class Weight cfm Horizontal and overhead applications Chipping Hammer MCH-2/3/4 15# 16-19 lbs 26-33 Industrial applications

More information

Diaphragm & Peristaltic Metering Pump

Diaphragm & Peristaltic Metering Pump Diaphragm & Peristaltic Metering Pump Pressure (BAR) Pulsafeeder Expertise Since 1936, Pulsafeeder, Incorporated has been the recognized leader in fluids handling, electronic pump controllers and systems

More information

Penberthy Automatic Injectors

Penberthy Automatic Injectors Hot water injectors used primarily as boiler feed pumps but also in numerous other applications for pumping liquids and discharging at high pressure and temperature Features Durable construction. Compact

More information

Welker Adjustable Probe with Check Valve and Welker Automatic Insertion Probe with Check Valve

Welker Adjustable Probe with Check Valve and Welker Automatic Insertion Probe with Check Valve a Installation, Operation, & Maintenance Manual Welker Adjustable Probe with Check Valve and Welker Automatic Insertion Probe with Check Valve Models AP-3MI & AIP-3MI The information in this manual has

More information

P843NSATS For Models: NL843N2, NL843NW2, and NL843NW3 PARTS CATALOG. Marine Generators Marine Diesel Engines Land-Based Generators

P843NSATS For Models: NL843N2, NL843NW2, and NL843NW3 PARTS CATALOG. Marine Generators Marine Diesel Engines Land-Based Generators P843NSATS For Models: NL843N2, NL843NW2, and NL843NW3 PARTS CATALOG Marine Generators Marine Diesel Engines Land-Based Generators CALIFORNIA Proposition 65 Warning: Diesel engine exhaust and some of its

More information

Regenerative Turbine Pumps

Regenerative Turbine Pumps Bulletin M M Series Regenerative Turbine Pumps Capacities to 8 GPM Heads to Feet MTH M Series Vertical base mount and horizontal pedestal mounted multi-stage regenerative turbine pumps represent the most

More information

Signet Conductivity/Resistivity Electrodes

Signet Conductivity/Resistivity Electrodes Signet 2818-2823 Conductivity/Resistivity Electrodes 2818 2819 2820 2821 2822 2823 Sanitary Features Standard process connections - Polypro - SS on 10 and 20 cell - Tri-clamp 1-1½ in., 2 - Opt. ½ in. NPT

More information

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS Model 31801 and 31800 Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS INDUSTRIAL DIAPHRAGM PUMPS FEATURES Run Dry Ability Self-Priming Thermal Overload Protected Motor Easy Installation Low Amp Draw Compact

More information

Reverse Osmosis Systems Section 11 Reverse Osmosis Systems

Reverse Osmosis Systems Section 11 Reverse Osmosis Systems Section 11 Section 11 Catalog 999701-NP Rev. E (03/16) Effective 03/01/16 Section 11 Table of Contents REVERSE OSMOSIS SYSTEMS SPECIFICATIONS AND DESIGN DATA PVE SERIES - 14,400-43,200 GPD...11-1 HVE SERIES

More information

Electromagnetic Flowmeters. Product Overview.

Electromagnetic Flowmeters. Product Overview. Electromagnetic Flowmeters Product Overview www.lcmeter.com Premier products, premier performance Liquid Controls offers a broad selection of electromagnetic (Mag) flow meters for industrial and water

More information

55-Gallon Powder Drum Truck

55-Gallon Powder Drum Truck Instruction Sheet P/N 0 0 -Gallon Powder Drum Truck for Bulk-Feed Powder Transfer Systems Description See Figure. The -gallon powder drum truck automatically adds bulk powder to a powder coating system

More information

Start UP Guide. Symmetra LX Tower Rack-Mount. UPS Models 200 V, 4-8 kva 208/240 V, 4-8 kva 220/230/240 V, 4-8 kva

Start UP Guide. Symmetra LX Tower Rack-Mount. UPS Models 200 V, 4-8 kva 208/240 V, 4-8 kva 220/230/240 V, 4-8 kva Start UP Guide Symmetra LX Tower Rack-Mount UPS Models 200 V, 4-8 kva 208/240 V, 4-8 kva 220/230/240 V, 4-8 kva 200 V, 4-16 kva 208/240 V, 4-16 kva 220/230/240 V, 4-16 kva Important Safety Messages SAVE

More information

series 5100 GAS/PNEUMATIC DRIVEN INJECTION PUMP DESCRIPTION APPLICATIONS

series 5100 GAS/PNEUMATIC DRIVEN INJECTION PUMP DESCRIPTION APPLICATIONS TEXSTEAM Pumps series 5100 GAS/PNEUMATIC DRIVEN INJECTION PUMP Series 5100 LP Wt. 45 pounds Microswitch Option Available DESCRIPTION The 5100 Series performs accurately because (1) the head is designed

More information

Series Direct contact and metal-to-metal seating makes the T-pattern globe stop valve ideal for most shut-off applications.

Series Direct contact and metal-to-metal seating makes the T-pattern globe stop valve ideal for most shut-off applications. 7 YARWAY Hancock T-Pattern Globe valves Direct contact and metal-to-metal seating makes the T-pattern globe stop valve ideal for most shut-off applications Features Heavy integral stellite hardfacing on

More information

Experience In Motion UZDL. API 610 (BB1) Between Bearings, Two-Stage, Axially Split Pump

Experience In Motion UZDL. API 610 (BB1) Between Bearings, Two-Stage, Axially Split Pump Experience In Motion UZDL API 610 (BB1) Between Bearings, Two-Stage, Axially Split Pump Pump Supplier To The World Flowserve is the driving force in the global industrial pump marketplace. No other pump

More information

Safety and General Information

Safety and General Information Safety and General Information Symmetra LX Tower Rack-Mount UPS Models 200 V, 4-8 kva 208/240 V, 4-8 kva 220/230/240 V, 4-8 kva 200 V, 4-16 kva 208/240 V, 4-16 kva 220/230/240 V, 4-16 kva Important Safety

More information