Reverse Osmosis Systems Section 11 Reverse Osmosis Systems

Size: px
Start display at page:

Download "Reverse Osmosis Systems Section 11 Reverse Osmosis Systems"

Transcription

1 Section 11 Section 11 Catalog NP Rev. E (03/16) Effective 03/01/16

2 Section 11 Table of Contents REVERSE OSMOSIS SYSTEMS SPECIFICATIONS AND DESIGN DATA PVE SERIES - 14,400-43,200 GPD HVE SERIES - 2,000-10,800 GPD MVE SERIES ,000 GPD LVE SERIES GPD REVERSE OSMOSIS SYSTEMS CONFIGURATIONS PVE SERIES 14,400 TO 43,200 GPD CAPACITY HVE SERIES BEST 2,000 TO 14,400 GPD CAPACITY HVE SERIES BETTER 2,000 TO 14,400 GPD CAPACITY MVE SERIES BETTER 500 TO 2,000 GPD CAPACITY LVE SERIES BETTER 250 TO 500 GPD CAPACITY REVERSE OSMOSIS COMPONENTS PRESSURE TANK KITS RO ACCESSORIES Section 11 Catalog NP Rev. E (03/16) Effective 03/01/16

3 Section 11 Reverse Osmosis Units Specifications and Design Data ECI PVE Series 14,400 43,200 GPD Capacity (10 30 GPM) Model R8F40 R12F40 R16F40 R20F40 R24F40 Product Flow (1) (2) GPM GPD 14,400 21,600 28,800 36,000 43,200 Feed Flow (GPM) Reject Flow (GPM) Recycle (GPM) Rejection 95-98% 95-98% 95-98% 95-98% 95-98% Recovery Range 40% (4) 40% (4) 50% (4) 50% (4) 50% (4) Membrane Size 4 x 40 4 x 40 4 x 40 4 x 40 4 x 40 Vessel Size 4 x 2 Long 4 x 2 Long 4 x 2 Long 4 x 2 Long 4 x 2 Long No. of Membranes Prefilter 5 Micron 5 Micron 5 Micron 5 Micron 5 Micron Pipe Size In Feed Product Reject Feed Pressure (psig) Pump HP Power 230V/460V 60Hz/3 ph 230V/460V 60Hz/3 ph 230V/460V 60Hz/3 ph 230V/460V 60Hz/3 ph 230V/460V 60Hz/3 ph Amps Dimensions (LxDxH) (3) 90 x 42 x x 42 x x 42 x x 42 x x 42 x 60 Notes: (1) Based upon feed water: SDI<3, free chlorine 0.0 mg/l maximum, ph 3-11 and temperature 77 O F. (2) System flows are design parameters. (3) All dimensions approximate. Additional 18 space required around system for maintenance. (4) Maximum recovery with recycle is 75%. Effective 03/01/

4 Section 11 Reverse Osmosis Units Specifications and Design Data ECI HVE Series 2,000 14,400 GPD Capacity ( GPM) Model R1F40 R2F40 R3F40 R4F40 R5F40 R6F40 R8F40 Product Flow (1) (2) GPM GPD 2,000 3,900 5,600 7,500 9,500 10,800 14,400 Feed Flow (GPM) Reject Flow (GPM) Recycle Yes Yes Yes Yes Yes Yes Yes Rejection 98% 98% 98% 98% 98% 98% 98% Recovery Range 18 75% 32 75% 42 75% 34 75% 37 75% 42 75% 50 75% Membrane Size 4 x 40 4 x 40 4 x 40 4 x 40 4 x 40 4 x 40 4 x 40 Vessel Size 1M 1M 1M 1M 1M 1M 1M Array 1 1:1 1:1:1 2:1:1 2:2:1 2:2:1:1 3:3:2 No. of Membranes Prefilter Pipe Size In Feed Pkg FNPT 0.75 FNPT 0.75 FNPT 1.0 FNPT 1.0 FNPT 1.0 FNPT 1.0 FNPT Feed Pkg FNPT 0.75 FNPT 0.75 FNPT 1.0 FNPT 1.0 FNPT 1.0 FNPT 1.0 FNPT Feed Pkg FNPT 0.75 FNPT 0.75 FNPT 1.0 FNPT 1.0 FNPT 1.0 FNPT 1.0 FNPT Product Pkg Tube Tube Tube 0.5 Tube 0.5 Tube 0.5 Tube 0.5 Tube Product Pkg FNPT 0.5 FNPT 0.5 FNPT 1.0 FNPT 1.0 FNPT 1.0 FNPT 1.0 FNPT Product - Pkg FNPT 0.75 FNPT 0.75 FNPT 0.75 FNPT 0.75 FNPT 0.75 FNPT 0.75 FNPT Reject Pkg MNPT MNPT MNPT 0.5 MNPT 0.5 MNPT 0..5 MNPT 0.5 FNPT Reject Pkg FNPT 0.5 FNPT 0.5 FNPT 1.0 FNPT 1.0 FNPT 1.0 FNPT 1.0 FNPT Reject Pkg FNPT 0.5 FNPT 0.5 FNPT 1.0 FNPT 1.0 FNPT 1.0 FNPT 1.0 FNPT Feed Pressure (psig) Pump HP 3/4 3/4 3/ Power Amps Dimensions (LxDxH) (3) 26 x 16 x 26 x 16 x 26 x 16 x 26 x 16 x 38 x 16 x 38 x 16 x 38 x 21 x Notes: (1) Based upon feed water: SDI<3, free chlorine 0.0 mg/l maximum, ph 2-11 and temperature 77 O F. (2) System flows are design parameters. (3) All dimensions approximate. Additional space required for maintenance. Effective 03/01/

5 Section 11 Reverse Osmosis Units Specifications and Design Data ECI MVE Series 500 2,000 GPD Capacity Model R2E12 R4E12 R4E12P Product Flow (1) (2) GPM GPD 500 1,000 2,000 Feed Flow (GPM) Reject Flow (GPM) Recycle No No Yes Rejection 95% 95% 95% Max Recovery 75% 75% 75% Membrane Size 2 x 12 3 x 12 3 x 12 Vessel Size 3 x 12 3 x 12 3 x 12 No. of Membranes Prefilter GAC/Sediment GAC/Sediment GAC/Sediment Pipe Size In Feed 1/2 NPT 1/2 NPT 1/2 NPT Product 3/8 3/8 3/8 Reject 3/8 3/8 3/8 Feed Pressure (psig) PSI Pump HP - - 1/3 Power 110V, Amps 4 4 Dimensions (LxDxH) (3) 21 x 12.5 x 30.9 Notes: (1) Based upon feed water: SDI<3, free chlorine 0.0 mg/l maximum, ph 3-11 and temperature 77 O F. (2) System flows are design parameters. (3) All dimensions approximate. Additional 18 space required around system for maintenance. Effective 03/01/

6 Section 11 Reverse Osmosis Units Specifications and Design Data ECI LVE Series GPD Capacity Model R1E12 R2E12 Product Flow (1) (2) GPM GPD Feed Flow (GPM).35.7 Reject Flow (GPM) Rejection 95% 95% Max Recovery 75% 75% Membrane Size 3 x 12 3 x 12 Vessel Size 3 x 12 3 x 12 No. of Membranes 1 2 Prefilter GAC/Sediment GAC/Sediment Pipe Size In Feed 3/8 3/8 Product 3/8 3/8 Reject 3/8 3/8 Feed Pressure (psig) Power PSI 24VDC Watts 25 Dimensions (LxDxH) (3) 14 x 6.06 x Notes: (1) Based upon feed water: SDI<3, free chlorine 0.0 mg/l maximum, ph 3-11 and temperature 77 O F. (2) System flows are design parameters. (3) All dimensions approximate. Additional 18 space required around system for maintenance. (4) Membrane performance 70 PSI, 77 o F, 40% recovery 250ppm NaCL Effective 03/01/

7 Section 11 PVE Series 14,400 to 43,200 GPD Capacity Best Features: = 5 micron pre-filter and housings = 4 x 40 Low Energy Membranes = Stainless Steel Membrane Housings = Automatic inlet shut-off valve = Pretreatment lockout = Pre-filter, post-filter, feed and concentrate pressure gauges = 3 Flow Meters - Permeate, Recycle and Concentrate = Feed and Product sample ports. = Product sample port on each membrane housing. = Feed Conductivity = Standard 230 / 460 Volt - 60 Hz / 3 ph Pump. = Low inlet pressure shutdown = Stainless Steel booster pump = NEMA 4 Control Panel = Adjustable Reject and Recycle = Permeate Quality Rinse = Auto Flush Standard = Operating Hours Display PVE Series - R12F40 Package Options: = PLC Control = Digital Flow Meters = Digital Pressure Readouts = Contact EcoWater for Engineered Systems Nominal Capacity GPD Model Part Membranes No. & Size (vessel) HP Ship Wt. Lbs. 14,400 R8F x ,600 F12F x ,800 R26F x ,400 36,000 R20F x ,750 43,200 R24F x ,100 Effective 03/01/

8 Section 11 HVE Series 2,000 to 14,400 GPD Capacity Best Features: = 4 x 40 low-energy TFC membranes = Smooth, quiet operating stainless steel, multi-stage centrifugal pumps with plastic impellers. = 3/4 or 2 HP 230/60 Hz/1 ph motors providing up to 185 PSI pressure (1 inlet) with 5-micron filter = Single power connection for all controls, switches, and solenoid valves = Stainless Steel Membrane Housings = Stainless Steel solenoid valves = Heavy-duty, Powder Coated Steel frame for durability and rust resistance = Pretreatment lockout = Low level connections = Low-pressure protection = Auto Re-start after shutdown = Waste recycle = Product and waste flow meter = Product TDS meter = All systems are fully tested and shipped fully assembled Package Options: = Auto flush = Stainless Steel frame R4F40-BEST Nominal Capacity GPD Model Part Membranes No. & Size HP Ship Wt. Lbs. 2,000 R1F40-BEST x 40 3/ ,900 R2F40-BEST x 40 3/ ,600 R3F40-BEST x 40 3/ ,500 R4F40-BEST x ,500 R5F40-BEST x ,800 R6F40-BEST x ,400 R8F4040-BEST x Effective 03/01/

9 Section 11 HVE Series 2,000 to 14,400 GPD Capacity Better Standard Features: = 4 x 40 low-energy TFC membranes = Smooth, quiet operating stainless steel, multi-stage centrifugal pumps with plastic impellers = 3/4 or 2 HP 230/60 Hz/1 ph motors providing up to 185 PSI pressure (1 inlet) with 5-micron filter = Single power connection for all controls, switches, and solenoid valves = Stainless Steel Membrane Housings = Stainless Steel solenoid valves = Heavy-duty, Powder Coated Steel frame for durability and rust resistance = Pretreatment lockout = Low level connections = Low-pressure protection = Auto Re-start after shutdown = Waste recycle = Product and waste flow meter = All systems are fully tested and shipped fully assembled Package Options: = Auto flush = Stainless Steel frame R2F40-BETTER Nominal Capacity GPD Model Part Membranes No. & Size HP Ship Wt. Lbs. 2,000 R1F40-BETTER x 40 3/ ,900 R2F40-BETTER x 40 3/ ,600 R3F40-BETTER x 40 3/ ,500 R4F40-BETTER x ,500 R5F40-BETTER x ,800 R6F40-BETTER x ,400 R8F40-BETTER x Effective 03/01/

10 Section 11 MVE Series 500 to 2,000 GPD Capacity Better Features: = Wall mount or floor/shelf mount = Zero clearance required on bottom and sides = All components can be serviced from front or top of unit = Pretreatment lockout = 3 x 12 XLP Low Pressure membranes = 1/3 HP 110/60 Hz/1-phase motors providing up to 125 PSI pressure = Easy to operate filter in, filter out, pump and product pressure gauges = Single power connection for all controls, switches, and solenoid valves = Carbon filter and 5-micron sediment filter = Smooth, quiet operating, brass vane-type pump (2,000 GPD unit only) = Standard plumbing connections - 1/2 Inlet, 3/8 permeate and drain connections = Stainless Steel solenoid valves = Heavy-duty, Powder Coated Steel cabinet for durability and rust resistance = All systems are fully tested and shipped fully assembled R4E12P-BETTER Nominal Capacity GPD Model Part Membranes No. & Size (vessel) HP Ship Wt. Lbs. 500 MVE-R2E12-BETTER x 12 N/A 75 1,000 MVE-R4E12-BETTER x12 N/A 80 2,000 MVE-R4E12P-BETTER x 12 1/3 100 Effective 03/01/

11 Section 11 LVE Series 250 to 500 GPD Capacity Better Features: = Compact Design - Wall mounted = Pretreatment Lockout - Disables RO production during regeneration = Single Power Connection - For all controls, switches and solenoid valves = Simple, Easy to Read Gauges - Filter In, Filter Out, and Product Pressure Gauges = High Flow, Low-Pressure XLP Membrane % maximum TDS rejection. Stands up to the most rugged of feed water conditions = Carbon and Sediment Filter included - Provides basic pretreatment, dechlorination and sediment removal down to 5 microns. = Standard Plumbing Connection - Uses 3/8 inlet, 3/8 permeate and drain connections = Heavy Duty - Powder-coated steel cabinet for durability and rust resistance. R2E12-BETTER Nominal Capacity GPD Model Part Membranes No. & Size (vessel) HP Ship Wt. Lbs. 250 LVE-R1E12-BETTER x12 N/A LVE-R2E12-BETTER x 12 N/A 80 Effective 03/01/

12 Section 11 Pressure Tank Kits Pressure Tank Package, PSC-48 Pressure Tank Package, PSC-80 Pressure Tank Package, PSC-119 Description Model Pressure Tank Package, PSC Includes: Pressure Tank, 21 x Pressure Switch Pressure Gauge, PSI Check Valve, 1 Spring Check Ball Valve, 1 SCH80 PVC Union Bushing, PVC 1.25 x1 TxT Instruction Sheet Description Model Pressure Tank Package, PSC Includes: Pressure Tank, 21 x Pressure Switch Pressure Gauge, PSI Check Valve, 1 Spring Check Ball Valve, 1 SCH80 PVC Union Bushing, PVC 1.25 x1 TxT Instruction Sheet Description Model Pressure Tank Package, PSC Includes: Pressure Tank, 24 x Pressure Switch Pressure Gauge, PSI Check Valve, 1 Spring Check Ball Valve, 1 SCH80 PVC Union Bushing, PVC 1.25 x1 TxT Instruction Sheet Effective 03/01/

13 Section 11 Reverse Osmosis Accessories Description Model Pressure Tank, 20 x40 35 Gal. Nominal Pressure Tank, 24 x46 60 Gal. Nominal Pressure Tank, 24 x Gal. Nominal Storage Tank, 300 Gal. Doorway w 1.25 Lower Fitting Storage Tank, 500 Gal. Doorway w 1.25 Lower Fitting NC Pressure Switch, PSI NC Float Switch, RO Shut Off with Open Wires - SPDT Float Switch, RO Shut Off with 110V Plug - RO Shut-off Float Switch, RO Shut Off with 220V - RO Shut-off Check Valve, 1 Spring Check Ball Valve, 1 SCH80 PVC Union Pressure Gauge, PSI - Rear Center 1/4 NPT Cover, MQ3-45 RO Delivery Pump Pump, MQ3-45 RO Delivery 110V 20 GPM Pump, MQ3-45 RO Delivery 220V 20 GPM Bulkhead Fitting,.5 for RO Fill Bulkhead Fitting,.75 for RO Fill Bulkhead Fitting, 1 for RO Fill Blending Kit HVE, w/flow Meter Blending Kit MVE w/flow Meter HVE/MVE - 5 Micron Sediment Filter MVE - Carbon Filter MVE/LVE - Membrane & Housing Kit HVE - Autoflush Kit LVE - RO Pump Kit RO Membrane - Low Energy - 4x Effective 03/01/

BKI 1000 Commercial/Industrial RO Unit

BKI 1000 Commercial/Industrial RO Unit BKI 1000 Commercial/Industrial RO Unit Fully Equipped and Customizable Higher Recovery Rates Surgical steel membrane housings (not shown) Lower Energy Consumption High Flow Low-Energy Membranes Lower Maintenance

More information

WATER TREATMENT COMPONENTS. Residential R.O. components

WATER TREATMENT COMPONENTS. Residential R.O. components WATER TREATMENT COMPONENTS Residential R.O. components 1,8 Residential CSM Membranes 2017 10-01-01-EN 1,8 Residential CSM Membranes OLD MODEL NAME RE1810-30 RE1812-35 MCRE1812-50 DA050 RE1812-50 MCRE1812-60

More information

DETAILED EQUIPMENT SPECIFICATION MRO-4 SERIES REVERSE OSMOSIS SYSTEMS

DETAILED EQUIPMENT SPECIFICATION MRO-4 SERIES REVERSE OSMOSIS SYSTEMS 5356 Hillside Avenue Indianapolis, IN 46220 P: +1 888-56-Water (569-2837) F: +1 317-255-4727 info@nancrede.com www.nancrede.com DETAILED EQUIPMENT SPECIFICATION MRO-4 SERIES REVERSE OSMOSIS SYSTEMS 1.0

More information

EQUIPMENT DATA SHEET RO

EQUIPMENT DATA SHEET RO NORMAL OPERATING PARAMETERS UNIT CONFIGURATION Operating Water Temperature 77 F # Passes 1 Min. Inlet Water Pressure 10 PSI # Stages 1 Maximum SDI < 3 Array 12 Maximum Turbidity < 1 NTU Hsg Size,Mat'l,psi,Mfr

More information

DETAILED EQUIPMENT SPECIFICATION HIGH PURITY LABORATORY WATER SYSTEM

DETAILED EQUIPMENT SPECIFICATION HIGH PURITY LABORATORY WATER SYSTEM 5356 Hillside Avenue Indianapolis, IN 46220 P: +1 888-56-Water (569-2837) F: +1 317-255-4727 info@nancrede.com www.nancrede.com DETAILED EQUIPMENT SPECIFICATION HIGH PURITY LABORATORY WATER SYSTEM 1.0

More information

EQUIPMENT DATA SHEET RO

EQUIPMENT DATA SHEET RO NORMAL OPERATING PARAMETERS Operating Water Temperature 70 F # Passes Per Unit 2 Min. Inlet Water Pressure 30 PSI # Stages Per Pass 3 Maximum SDI 3 Array Per Pass 3:2:1 Maximum Turbidity < 1 NTU Hsg Size,Mat'l,psi,Mfr

More information

EQUIPMENT DATA SHEET RO

EQUIPMENT DATA SHEET RO NORMAL OPERATING PARAMETERS Operating Water Temperature 70 F # Units Per Container 4 A, B, C & D Min. Inlet Water Pressure 30 PSI # Stages Per Unit 3 Maximum SDI 3 SDI Stage Array Per Unit 3:2:1 Maximum

More information

Pure Water. Anytime, Anywhere. Marine Desalination Systems

Pure Water. Anytime, Anywhere. Marine Desalination Systems Pure Water Anytime, Anywhere Marine Desalination Systems Legend From 475 to 1,850 gallons per day (1,800-7,000 liters per day) Fully Automatic High Production Capability The Blue Water LEGEND series uses

More information

Nautilus Gallon Per Day Modular Watermakers.

Nautilus Gallon Per Day Modular Watermakers. Nautilus 300-2000 Gallon Per Day Modular Watermakers www.makeh2o.com Our popular Nautilus series systems have a number of new features which make this simple, rugged and proven design even better! All

More information

Residential R.O. components

Residential R.O. components Residential R.O. components WATER TREATMENT COMPONENTS 1,8 RESIDENTIAL CSM MEMBRANES 2015 10-01-01-EN 1,8 RESIDENTIAL CSM MEMBRANES Ref. Model Name RE1810-30 DA050A RE1810-50 RE1812-35 DA050 DA051 DA052

More information

Reverse Osmosis System

Reverse Osmosis System Reverse Osmosis System Service Manual 5842 W 34th St, Houston, TX 77092 1.800.999.9878 1.713.683.9878 www.colemanhanna.com Find us on Facebook: /ColemanHannaCarwash HANNA REVERSE OSMOSIS SYSTEMS Table

More information

TABLE OF CONTENTS. A. Figure # 1 General System Drawing B. Figure # 2 Package One Controller Drawing C. Figure # 3 Package Two Controller Drawing

TABLE OF CONTENTS. A. Figure # 1 General System Drawing B. Figure # 2 Package One Controller Drawing C. Figure # 3 Package Two Controller Drawing TABLE OF CONTENTS I. Introduction A. Specifications B. Overview C. Pre-treatment II. Controls, Indicators, and Components III. Operation A. Figure # 1 General System Drawing B. Figure # 2 Package One Controller

More information

ALAMO WATER REFINERS REVERSE OSMOSIS INSTALLATION AND OPERATION MANUAL R14-SERIES

ALAMO WATER REFINERS REVERSE OSMOSIS INSTALLATION AND OPERATION MANUAL R14-SERIES ALAMO WATER REFINERS REVERSE OSMOSIS INSTALLATION AND OPERATION MANUAL R14-SERIES Alamo Water Refiners, Inc. 13700 Hwy. 90 West San Antonio, TX 78245 U.S.A. 210-677-8400 www.alamowater.com IMPORTANT Please

More information

Reverse Osmosis (RO) Water Treatment Systems

Reverse Osmosis (RO) Water Treatment Systems Reverse Osmosis (RO) Water Treatment Systems Commercial and Industrial RO Systems & Components Table of Contents Packaged Reverse Osmosis Water Treatment Systems....3 Small Size RO System.... 4 LPRO-16

More information

Hydrosafe - Model HSFS

Hydrosafe - Model HSFS Hydrosafe - Model HSFS Whole House Filtration and Water Treatment Triple-Treat Protection Three-In-One Technology The innovative HydroSafe filtration system incorporates three technologies in one unit

More information

User s Manual SE MODELS SEA XCHANGE SE-350 SE SE SE-800

User s Manual SE MODELS SEA XCHANGE SE-350 SE SE SE-800 User s Manual SE MODELS SEA XCHANGE SE-350 SE-600-1 SE-600-2 SE-800 2786 SW 3 RD AVE FORT LAUDERDALE, FL Phone 954-533-5640 Email: info@spotzerowater.com www.spotzerowater.com SE Models 1 4/24/2017 TABLE

More information

ProMinent. ProMinent D4a Metering Pumps with built-in proportional controllers

ProMinent. ProMinent D4a Metering Pumps with built-in proportional controllers D4a Metering Pumps with built-in proportional controllers A series of solenoid-driven metering pumps with built-in ph controller, oxidation-reduction potential (Redox) controller or chlorine controller.

More information

Fleck Top Mount Section 1 Fiberglass Softeners

Fleck Top Mount Section 1 Fiberglass Softeners Fleck Top Mount Section 1 Fleck Top Mount *Shown with factory SKID & Interconnecting Plumbing *Shown with factory SKID & Interconnecting Plumbing Section 01 Fleck Top Mount Catalog 999701-NP Rev. F (05/17)

More information

User s Manual SXII MODELS SEA XCHANGE SXII-600 SXII SXII-1200 SXII-1800 SXII-2200

User s Manual SXII MODELS SEA XCHANGE SXII-600 SXII SXII-1200 SXII-1800 SXII-2200 User s Manual SXII MODELS SEA XCHANGE SXII-600 SXII-600-2 SXII-1200 SXII-1800 SXII-2200 2786 SW 3 RD AVE FORT LAUDERDALE, FL Phone 954-533-5640 Email: info@spotzerowater.com www.spotzerowater.com SXII

More information

PRESSURE GAGES AND TEST TAPS

PRESSURE GAGES AND TEST TAPS CAT 500.1 FRF series filters. Polyglass 100 psi vessels with top mount Task Master II 1 ½ valve and single point PVC internals. FMF series filters. Carbon steel epoxy lined and coated vessels with side

More information

R & D SPECIALTIES USER'S MANUAL

R & D SPECIALTIES USER'S MANUAL R & D SPECIALTIES R & D SPECIALTIES ROTrol II Version D USER'S MANUAL No part of this document may be copied or reproduced in any form or by any means without the prior written permission of R & D Specialties.

More information

Drawdown Gal L Gal L Gal L. Horizontal Tanks

Drawdown Gal L Gal L Gal L. Horizontal Tanks E36 Pressure Tanks Pressure Tanks - Steel For use wherever pressurized tanks are needed in water system applications Controlled water cell Heavy duty gauge steel construction Warranty: 5 year limited Total

More information

Fleck Fiberglass Section 9 Chloride Dealkalizers

Fleck Fiberglass Section 9 Chloride Dealkalizers Fleck Fiberglass Section 9 Fleck Fiberglass (*) Note: Steel tanks & Plastic Valve Nest (*PVN) systems are offered on custom quote basis Section 9 - Fleck Fiberglass Catalog 999701-NP Rev. F (05/17) Effective

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual IOM-HS-QTCubeMax Installation, Operation and Maintenance Manual QT TM Cube Max TM Models: QTCBMX-1S-1M, QTCBMX-2S-1M, QTCBMX-3S-1M, QTCBMX-4S-1M, QTCBMX-1L-1M, QTCBMX-2L-1M, QTCBMX-3L-1M, QTCBMX-4L-1M,

More information

Atomizer 36-DC User Guide

Atomizer 36-DC User Guide TECHNICAL INSTRUCTIONS Atomizer 36-DC User Guide SERVICE CASE HUMIDIFICATION Specification Sheet... 2 Installation Guide... 3 Layout Diagram... 4 Maintenance Guide... 5 Wiring Diagram... 6 Pull Sheet...

More information

This catalog contains the following geothermal accessory products and specification guides:

This catalog contains the following geothermal accessory products and specification guides: f o r r e s i d e n t i a l s y s t e m s Geothermal systems offer an effective way to cut utility costs while ensuring comfort. Heat Controller s line includes two stage and single stage geothermal heat

More information

RX-AFRO3-AQ Installation Manual

RX-AFRO3-AQ Installation Manual www.aquafilter.com RX-AFRO-AQ Installation Manual . Safety notes WARNING! The system cannot be used for biologically contaminated water or water of unknown origin. The system must be installed by a trained

More information

Fleck Epoxy Lined Section 2 Steel Softeners

Fleck Epoxy Lined Section 2 Steel Softeners Epoxy Lined Section 2 Epoxy Lined *Shown with factory SKID & Plumbing Section 02 Epoxy Lined Catalog 999701-NP Rev. F (05/17) Effective 05/01/17 Section 2 Table of Contents Epoxy Lined Steel Softener Specifications

More information

BUILT SMART, CLEANS TOUGH!

BUILT SMART, CLEANS TOUGH! BUILT SMART, CLEANS TOUGH! BUILT SMART, CLEANS TOUGH! We understand that our customers have their unique cleaning challenges. SoAX Cleaning Systems is a line of pressure washers and self-serve equipment

More information

SECTION 1. Fleck Fiberglass Softeners. *Shown with factory SKID & Interconnecting Plumbing

SECTION 1. Fleck Fiberglass Softeners. *Shown with factory SKID & Interconnecting Plumbing SECTION 1 *Shown with factory SKID & Interconnecting Plumbing Fleck Fiberglass Softeners Section 01 Fleck Fiberglass softeners Catalog 999502 Effective 01/01/13 Section 01 Fleck Fiberglass softeners Catalog

More information

Energy Recovery Device isave 21-40

Energy Recovery Device isave 21-40 MAKING MODERN LIVING POSSIBLE Data sheet Energy Recovery Device isave 21-40 www.isave.danfoss.com Table of Contents 1. General information....3 2. Benefits...3 3. Technical data...4 3.1 isave without motor...4

More information

INLINE 1100 COMPACT, MULTI-PUMP SYSTEM

INLINE 1100 COMPACT, MULTI-PUMP SYSTEM INLINE 00 COMPACT, MULTI-PUMP SYSTEM The Franklin Electric Inline 00 SpecPAK TM Pressure Boosting System connects easily to nearly any commercial, industrial, or multi-residential plumbing configuration

More information

AD-830. Parts Manual thru 1997

AD-830. Parts Manual thru 1997 AD-830 Parts Manual 1995 thru 1997 American Dryer Corporation 88 Currant Road Fall River, MA 02720-4781 Telephone: (508) 678-9010 / Fax: (508) 678-9447 E-mail address: service@amdry.com 072696 092497DX/abe

More information

Pump Specifications FL100 Series Submersible Effluent Pump

Pump Specifications FL100 Series Submersible Effluent Pump Head (Feet) Head (Meters) Pump Specifications FL100 Series Submersible Effluent Pump Flow (Liters Per Minute) 100 0 38 76 114 151 189 227 265 303 341 379 416 30 90 27 80 24 70 21 60 18 50 15 40 12 30 9

More information

R & D SPECIALTIES ROTROL I USER'S MANUAL

R & D SPECIALTIES ROTROL I USER'S MANUAL R & D SPECIALTIES ROTROL I USER'S MANUAL TABLE OF CONTENTS INTRODUCTION...2 SPECIFICATIONS...2 CONTROLS AND INDICATORS...3 TIME DELAYS...4 INSTALLATION...5 SYSTEM OPERATION...9 TROUBLESHOOTING...13 OPTIONAL

More information

Jet Pumps. Convertible Shallow Well. 6/13 Rev (3/14)

Jet Pumps. Convertible Shallow Well. 6/13 Rev (3/14) Jet Pumps Convertible Shallow Well 6/13 Rev (3/14) Table of Contents Page General Information...2-4 Nema J Motor Pumps 8100 Series - Shallow Well... 5 8200 Series - Convertible...6-7 Square Flange Motor

More information

This catalog is just the beginning of the service we can offer you in ever.

This catalog is just the beginning of the service we can offer you in ever. µs HIGHLY EFFICIENT SOLUTION µs Energy saving Water saving Low noise µs Gentle to installations High Salt Rejection Rate Water is a very precious commodity today. Hence, energy and economic efficiency

More information

BATTERY WASH CABINETS, WASH STATIONS, RECIRCULATION/NEUTRALIZATION SYSTEM

BATTERY WASH CABINETS, WASH STATIONS, RECIRCULATION/NEUTRALIZATION SYSTEM BATTERY WASH CABINETS, WASH STATIONS, RECIRCULATION/NEUTRALIZATION SYSTEM Complete Product Line A cost-effective solution for extending the life of batteries and reducing lift truck electrical problems

More information

Mar Cor Purification. M2 Portable Ergonomic RO Cart Operation & Maintenance Manual

Mar Cor Purification. M2 Portable Ergonomic RO Cart Operation & Maintenance Manual Mar Cor Purification M2 Portable Ergonomic RO Cart M2 Portable Ergonomic RO Cart TABLE OF CONTENTS Page CHAPTER ONE: GENERAL INFORMATION 1 Section 1.1 General Overview 1 1.2 The Operator s Manual 3 1.3

More information

GE Infrastructure Water and Process Technologies. Merlin Point of Use Drinking Water System. Installation and Maintenance Manual

GE Infrastructure Water and Process Technologies. Merlin Point of Use Drinking Water System. Installation and Maintenance Manual GE Infrastructure Water and Process Technologies Merlin Point of Use Drinking Water System Installation and Maintenance Manual 2 SAFETY GUIDES Read and follow all steps and guides carefully before installing

More information

Model Model Model

Model Model Model Filter Separators Model 9003 Model 9004 Model 9001 & 9032 Model 9002 EXAIR's Filter Separators remove water, dirt and rust from your compressed air system. They prevent these contaminants from plugging

More information

INLINE 1100 COMPACT, MULTI-PUMP SYSTEM. franklinwater.com

INLINE 1100 COMPACT, MULTI-PUMP SYSTEM. franklinwater.com INLINE 0 COMPACT, MULTI-PUMP SYSTEM The Franklin Electric Inline 0 SpecPAK Pressure Boosting System connects easily to nearly any commercial, industrial, or multi-residential plumbing configuration to

More information

EPDM,(Options for Buna, Viton - Depending on Process) B-7 All Thread w/ Stainless Sleeve

EPDM,(Options for Buna, Viton - Depending on Process) B-7 All Thread w/ Stainless Sleeve 26. S ERIES i SPECIFICATIONS 26-2 SYSTEM COMPONENT SPECIFICATIONS 1] Filter Pack Membrane: Membrane Area: Maximum Operating Temperature: Allowable Feed Slurry Ph Range: Elastomers (O-rings): Filter Pack

More information

PRE-INSTALLATION GUIDE

PRE-INSTALLATION GUIDE Dry Vacuum System Part Numbers V3, V5, V7, 2V3, 2V3CT, 2V5, 2V5CT, 2V7, 3V5 and 4V5 PRE-INSTALLATION GUIDE All pumps comply with NFPA 99C level 3 requirements. All installations must conform to local codes.

More information

HIGH CAPACITY CENTRIFUGAL & SPRINKLER PUMPS

HIGH CAPACITY CENTRIFUGAL & SPRINKLER PUMPS HIGH CAPACITY CENTRIFUGAL & SPRINKLER PUMPS FW0724 0707 Supersedes 1005 Straight Centrifugal Pumps Electric Motors Heavy Duty Straight Centrifugal Pumps High Head Straight Centrifugal Pumps Stainless Steel

More information

In-Duct High Pressure Nozzle Humidification System - HP HVAC Series Submittal Drawings

In-Duct High Pressure Nozzle Humidification System - HP HVAC Series Submittal Drawings In-Duct High Pressure Nozzle Humidification System - HP HVAC Series Submittal Drawings Date: Job Name: Contractor: Contractor or Order No.: Engineer: Agent: Agent P.O. No.: Date Ordered: Date Required:

More information

Operating Instructions ProMinent. Backpressure and Pressure Relief Valves

Operating Instructions ProMinent. Backpressure and Pressure Relief Valves Operating Instructions and Valves Contents Page Safety Instructions... 2 Unpacking... 2 Introduction... 2 Installation... 3 Description of Controls & Operation... 5 Helpful Tips... 5 Specifications...

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual IOM-HS-QTColdBevMax Installation, Operation and Maintenance Manual QT TM Cold Bev Max TM Models: QTCLDBMX-1S-.5M, QTCLDBMX-2S-.5M, QTCLDBMX-3S-.5M, QTCLDBMX-4S-.5M, QTCLDBMX-5S-.5M Tested and Certified

More information

Non-Metallic Seal-less Mag-Drive Pumps

Non-Metallic Seal-less Mag-Drive Pumps Non-Metallic Seal-less Mag-Drive Pumps Seal-less Mag-Drive Pump Specialists SOLID PP & PVDF Thermoplastic Mag-Drive Pumps Centrifugal, Turbine & Self-Priming From WARRENDER: Advanced design, materials

More information

Pump Specifications LE70-Series 3/4 HP Submersible Sewage Pump

Pump Specifications LE70-Series 3/4 HP Submersible Sewage Pump Pump Specifications LE70-Series 3/4 HP Submersible Sewage Pump LE70-P1 R9/3/2013 Copyright 2013 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice. LE70-Series Dimensional

More information

BECSys CO 2 Feeder. BECSys CO 2 Feed System Data Sheet. Description. Features

BECSys CO 2 Feeder. BECSys CO 2 Feed System Data Sheet. Description. Features Description BECSys CO 2 Feed Systems provide a rugged and reliable solution to ph control in aquatics facilities. CO 2 is recognized as a safe and easy-to-use method for ph control. BECSys CO 2 Feeder

More information

Pump Specifications LE70-Series 3/4 HP Submersible Sewage Pump

Pump Specifications LE70-Series 3/4 HP Submersible Sewage Pump Pump Specifications LE70-Series 3/4 HP Submersible Sewage Pump LE70-P1 R3/2/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice. LE70-Series Dimensional

More information

CAT231.1 PRESSURE GAUGE AND TEST TAP KIT SKID MOUNTING 220V, 50HZ, 1Ø OPERATING CONDITIONS 25 TO 100 PSI 100 F MAX IMUM TEMPERATURE SERIES METER

CAT231.1 PRESSURE GAUGE AND TEST TAP KIT SKID MOUNTING 220V, 50HZ, 1Ø OPERATING CONDITIONS 25 TO 100 PSI 100 F MAX IMUM TEMPERATURE SERIES METER CAT231.1 STANDARD FEATURES TASK MASTER III - 1 ½ / 2 - FIVE CYCLE 316 STAINLESS STEEL VALVE - SIDE MOUNT SUPER FLOW KIT S ON 2, 3 & 4 SYSTEMS (SERVICE FLOW BYPASS DIAPHRAGM VALVES) ERCt ELECTRONIC TIMER

More information

PRODUCT CATALOG BUILT FOR HEAVY-DUTY PERFORMANCE

PRODUCT CATALOG BUILT FOR HEAVY-DUTY PERFORMANCE PRODUCT CATALOG BUILT FOR HEAVY-DUTY PERFORMANCE MADE IN THE USA 532 CFM Reliable Efficient Cost Effective Exclusive Manufacturer 800-253-5500 887 Vacuum Pump - Page 3 887 Hydraulic Drive Pump - Page 4

More information

High Capacity Centrifugal & Sprinkler Pumps

High Capacity Centrifugal & Sprinkler Pumps High Capacity Centrifugal & Sprinkler Pumps FW0724 1016 Supersedes 0212 Stainless steel or cast iron construction Stainless steel impellers Discharge rotates in 90 increments on some models Pressures to

More information

Energy Recovery Device isave 21-40

Energy Recovery Device isave 21-40 Data sheet Energy Recovery Device isave 21-40 www.isave.danfoss.com 521b1116 / dkcfn.pd.003.a2.02 1. General information The isave 21-40 consists of an isobaric pressure exchanger (PE), a high pressure

More information

Pumps and Water Systems

Pumps and Water Systems Pumps and Water Systems U.S. 2010 List Prices Table of Contents A5817P 8-1-10 Description Page Description Page 4" Submersible Pumps A+ and S Series, PENTEK Fitted 2-4 T Composite Series, PENTEK Fitted

More information

Pump Specifications LE100-Series 1HP Submersible Sewage Pump

Pump Specifications LE100-Series 1HP Submersible Sewage Pump Pump Specifications LE100-Series 1HP Submersible Sewage Pump LE100-P1 R8/5/2014 Copyright 2014 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice. LE100-Series Dimensional

More information

Smart controls Reliable operation User friendly design Plug and play operation

Smart controls Reliable operation User friendly design Plug and play operation Series H2-ID1 RAINSETS Series H2-ID1 Rainsets manage the distribution and water treatment functions of commercial rainwater system installations. The modular H2-ID1 series is designed for indoor installations

More information

PRF-RO. Continuous Flow RO

PRF-RO. Continuous Flow RO Continuous Flow RO History/Evolution Launched September 2004 Innovative Features Continuous flow No electricity required Minimum of 490 gpd vs 18-50 GPD* No storage tank needed for most applications New

More information

earth safe Fuel Systems for Critical Power

earth safe Fuel Systems for Critical Power Point Level Sensors S100 Tank Refill Level Sensor 4/5 Point S101 Tank High level Sensor 3 Point S102 Tank Low Level Sensor 1 Point S103 Tank High Level Vent Sensor Level Transmitters S120 Tank Level Transmitter

More information

INLINE 1100 STAGED PALLET SYSTEM. franklinwater.com

INLINE 1100 STAGED PALLET SYSTEM. franklinwater.com INLINE 00 STAGED PALLET SYSTEM The Franklin Electric Inline 00 SpecPAK TM Pressure Boosting System connects easily to nearly any commercial, industrial, or multi-residential plumbing configuration to provide

More information

EZ SDI TM Booster Pump Assembly

EZ SDI TM Booster Pump Assembly EZ SDI TM Booster Pump Assembly Installation and Operating Manual 505-334-5865 ph 505-334-5867 fax www.rodisystems.com email: info@rodisystems.com 936 Highway 516 Aztec, NM 87410-2828 Manual Revisions

More information

CAT231.1 SHUT OFF KIT (SOK) TO PREVENT BYPASS PRESSURE GAUGE AND TEST TAP KIT SKID MOUNTING 220V, 50HZ, 1Ø

CAT231.1 SHUT OFF KIT (SOK) TO PREVENT BYPASS PRESSURE GAUGE AND TEST TAP KIT SKID MOUNTING 220V, 50HZ, 1Ø CAT231.1 STANDARD TASK MASTER III - 1 ½ VALVE 316 SS - SIDE MOUNT SERVICE FLOW BYPASS DIAPHRAGM VALVES. ERCt ELECTRONIC TIMER 100 PSI EPOXY LINED AND COATED CARBON STEEL MINERAL TANKS ACCUMATIC BRINE SYSTEM.

More information

APP S 674 pumps APP S / APP S APP S

APP S 674 pumps APP S / APP S APP S MAKING MODERN LIVING POSSIBLE Data sheet APP S 674 3.0-3.5 / APP S 674 5.1-9.0 APP S 674 21-38 ro-solutions.com Table of Contents 1. Introduction...3 2. Benefits...3 3. Application areas...3 4. Technical

More information

See Water Pressure Reducing Valves Catalog (PHBRWPRV) for more detailed information about the products in this section.

See Water Pressure Reducing Valves Catalog (PHBRWPRV) for more detailed information about the products in this section. See Catalog (PHBRWPRV) for more detailed information about the products in this section. WATER PRESSURE REDUCING VALVES PR (36LF) SERIES RESIDENTIAL AND COMMERCIAL APPLICATIONS The Apollo 36LF pressure

More information

The electric motors are designed for driving equipment that requires continuous operation, and their high efficiency reduces energy consumption.

The electric motors are designed for driving equipment that requires continuous operation, and their high efficiency reduces energy consumption. DATA SHEET Sea Water Pump with Energy Recovery SWPE 1. General information The SWPE energy recovery unit consists of an APP pump and an motor, both connected to a double shafted electric motor. Energy

More information

NOTE: LEH100-Series high-head pumps require a minimum application of 15' head. Do not use pump in this area use a smaller pump.

NOTE: LEH100-Series high-head pumps require a minimum application of 15' head. Do not use pump in this area use a smaller pump. Pump Specifications LEH100-Series 1HP Submersible Sewage Pump NOTE: LEH100-Series high-head pumps require a minimum application of 15' head. Do not use pump in this area use a smaller pump. LEH100-P1 R12/19/2012

More information

VERTICAL MULTI-STAGE PUMPS

VERTICAL MULTI-STAGE PUMPS VR SERIES - 6 HZ FEATURES All 316 stainless steel hydraulic components for superior durability, efficiency, and performance over a wide variety of applications Rugged NEMA motor mounting with oversized

More information

BLAST-TEC PRO. Rotating Turbo Nozzles. Optimization & Troubleshooting Guide REV C revc0118

BLAST-TEC PRO. Rotating Turbo Nozzles. Optimization & Troubleshooting Guide REV C revc0118 BLAST-TEC PRO Rotating Turbo Nozzles Optimization & Troubleshooting Guide REV C 4000002 revc08 Hydra-Flex, Hydra-Flex, Inc. 208 Inc. 208 TABLE OF CONTENTS Product Overview Product Line Description Specifications

More information

Iron Gate Air Pump System Manual

Iron Gate Air Pump System Manual Iron Gate Air Pump System Manual Installation and Operating Instructions Iron Gate Iron Filter System Manufactured by: R.E Prescott Co., Inc. 10 Railroad Avenue Exeter, New Hampshire 03833 Phone: (603)

More information

EZ SERIES BOOSTER PUMPS

EZ SERIES BOOSTER PUMPS EZ SERIES BOOSTER PUMPS Cast Iron And Stainless Steel Booster Pumps Webtrol has been building Booster Pumps for over years for various industrial, commercial and agricultural uses and has long been a leader

More information

VERTICAL MULTI-STAGE PUMPS

VERTICAL MULTI-STAGE PUMPS VR SERIES - 6 HZ FEATURES All 316 SS hydraulic components for superior durability, efficiency, and performance over a wide variety of applications Rugged NEMA motor mounting with oversized ball bearings

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS CapDI SYSTEMS TECHNICAL SPECIFICATIONS CapDI Voltea CapDI Membrane Capacitive Deionization We specialize in tunable water deionization that is designed to remove total dissolved salts (TDS) from a variety

More information

ISLAND EXPLORER SERIES REVERSE OSMOSIS DESALINATOR INSTALLATION & OPERATION MANUAL

ISLAND EXPLORER SERIES REVERSE OSMOSIS DESALINATOR INSTALLATION & OPERATION MANUAL ISLAND EXPLORER SERIES REVERSE OSMOSIS DESALINATOR INSTALLATION & OPERATION MANUAL 3000 E 2 ND STREET THE DALLES, OR 97058 USA PHONE: 800-548-4502 541-296-4562 FAX: 541-296-3954 uswatermaker@gorge.net

More information

Pump Specifications FL60/FLH60 Series 6/10 hp Submersible Effluent Pump

Pump Specifications FL60/FLH60 Series 6/10 hp Submersible Effluent Pump Head (Feet) Head (Meters) Pump Specifications FL60/FLH60 Series 6/10 hp Submersible Effluent Pump 70 Flow (Liters Per Minute) 0 38 76 114 151 189 227 265 303 341 379 21 FLH 60 60 FL 60 18 50 15 40 12 30

More information

BACK TO THE FUTURE: INNOVATION & ENERGY EFFICIENCY ON A LOW TDS BWRO RETROFIT/EXPANSION

BACK TO THE FUTURE: INNOVATION & ENERGY EFFICIENCY ON A LOW TDS BWRO RETROFIT/EXPANSION BACK TO THE FUTURE: INNOVATION & ENERGY EFFICIENCY ON A LOW TDS BWRO RETROFIT/EXPANSION Authors: Presenter: Bruce D. Goodin Juan Miguel Pinto Robert R. Butow Bruce D. Goodin Principal Sea Level Systems,

More information

TotalPac 3 Deluge, Electric release Remote controlled system

TotalPac 3 Deluge, Electric release Remote controlled system (Optional) DESCRIPTION This TOTALPAC 3 integrated fire protection system by FireFlex Systems Inc. consists of a deluge system trim totally preassembled, pre-wired and factory tested. All electrical and

More information

Spin Klin 12" Super Flow

Spin Klin 12 Super Flow Spin Klin 12" Super Flow w w w. a r k a l - f i l t e r s. c o m Galaxy Super Flow Spin Klin Battery Standard Automatic Backwash Operation and Maintenance Manual Filtration Process During filtration, water

More information

NEW! BOOSTER PUMPS. HBP/HBPS series 4" horizontal booster pumps. booster pumps

NEW! BOOSTER PUMPS. HBP/HBPS series 4 horizontal booster pumps. booster pumps HBP/HBPS series 4" horizontal The HBP/HBPS Series Booster Pumps are the most durable available. The patented SignaSeal floating impeller design minimizes thrust loads, allowing for continuous operation

More information

Data sheet. Data sheet. APP pumps APP APP Pumps APP 53 / APP 65 / APP 78 / APP 86. ro-solutions.com. hpp.danfoss.com

Data sheet. Data sheet. APP pumps APP APP Pumps APP 53 / APP 65 / APP 78 / APP 86. ro-solutions.com. hpp.danfoss.com Data sheet Data sheet APP Pumps APP 53 / APP 65 / APP 78 / APP 86 APP pumps APP 53-86 ro-solutions.com hpp.danfoss.com Table of Contents 1. Introduction...3 2. Benefits...3 3. Application examples...3

More information

AGRICULTURE GREENHOUSE LANDSCAPE

AGRICULTURE GREENHOUSE LANDSCAPE AGRICULTURE GREENHOUSE LANDSCAPE Fertilizer & Chemical proportional water driven injectors, with no ( other energy required I n j e c t o r s A step up from Different Models Applications Fertigation Chlorination

More information

Pump Specifications FL50 Series 1/2 hp Submersible Effluent Pump

Pump Specifications FL50 Series 1/2 hp Submersible Effluent Pump Head (Feet) Head (Meters) Pump Specifications FL50 Series 1/2 hp Submersible Effluent Pump Flow (Liters Per Minute) 60 0 38 76 114 151 189 227 265 303 341 379 18 50 15 40 12 30 9 20 6 10 3 0 0 0 10 20

More information

EJECTORS GENERAL OPERATION & MAINTENANCE MANUAL

EJECTORS GENERAL OPERATION & MAINTENANCE MANUAL EJECTORS GENERAL OPERATION & MAINTENANCE MANUAL The information contained in this manual was current at the time of printing. The most current versions of all Hydro Instruments manuals can be found on

More information

DuraMACTM Booster Pumps

DuraMACTM Booster Pumps DuraMACTM Booster Pumps Residential Light Commercial Commercial Industrial TM 11/15 Table of Contents Page Features Residential & Light Commercial/Irrigation...2-5 Page General Information Features (Vertical

More information

Section 2: Big Bubba Filtration System

Section 2: Big Bubba Filtration System Section 2: Big Bubba Filtration System Product Catalogue 2018 WattsIndustries.co.uk SECTION 2 BIG BUBBA FILTRATION SYSTEM The Watts Big Bubba Filtration System comprises of a high capacity polypropylene

More information

Pump Specifications FL150 Series Submersible Effluent Pump

Pump Specifications FL150 Series Submersible Effluent Pump Pump Specifications FL150 Series Submersible Effluent Pump FL150_P1 R3/2/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice. FL150-Series Dimensional

More information

Industrial automatic self-cleaning filters made in stainless steel AISI 316

Industrial automatic self-cleaning filters made in stainless steel AISI 316 Industrial automatic self-cleaning filters made in stainless steel AISI 316 FilBlue Introduction The automatic industrial selfcleaning filters are designed to remove all suspended solids from surface water

More information

EZ-View Flow Meters. General Design Features OPERATING PRINCIPLE

EZ-View Flow Meters. General Design Features OPERATING PRINCIPLE General Design Features 9 8 5 6 7 4 3 2 1 10 OPERATING PRINCIPLE The EZ-View Flow Meter is a variable area instrument. A precisionmolded, sharp-edged Orifice 1, located within the Piston Assembly, 2 forms

More information

Zone Valves and Parts (Honeywell)

Zone Valves and Parts (Honeywell) 28/11/14 B49 Zone Valves - Two Way Fan Coil Zone Valves and Parts (Honeywell) Two-way Fan Coil Valve, the VU53 high pressure zone valves are used to control the flow of hot or chilled water in commercial

More information

TotalPac 3 Double interlock Preaction, Electric/PneuLectric release Remote controlled system

TotalPac 3 Double interlock Preaction, Electric/PneuLectric release Remote controlled system (Optional) DESCRIPTION This TOTALPAC 3 integrated fire protection system by FireFlex Systems Inc. consists of a preaction system trim totally preassembled, pre-wired and factory tested. All electrical

More information

FIRE PROTECTION EQUIPMENT 2017 DATA SHEETS BSP FIRE RESERVES THE RIGHT TO ALTER INFORMATION CONTAINED IN THIS CATALOGUE AT ANY TIME.

FIRE PROTECTION EQUIPMENT 2017 DATA SHEETS BSP FIRE RESERVES THE RIGHT TO ALTER INFORMATION CONTAINED IN THIS CATALOGUE AT ANY TIME. FIRE PROTECTION EQUIPMENT 2017 DATA SHEETS BSP FIRE RESERVES THE RIGHT TO ALTER INFORMATION CONTAINED IN THIS CATALOGUE AT ANY TIME. DATA SHEET INDEX 36m x 19mm FIRE HOSE REEL RISER INSTALLATION DETAIL

More information

CIRCLE SEAL CONTROLS

CIRCLE SEAL CONTROLS CIRCLE SEAL CONTROLS ATKOMATIC SOLENOID VALVES INSTALLATION, MAINTENANCE, AND OPERATION INSTRUCTIONS 13000 SERIES Stainless, Normally Closed, Direct Lift, 3-Way Valve Installation Instructions WARNING:

More information

MGP/MGPS Series SPECIFICATIONS

MGP/MGPS Series SPECIFICATIONS The MGP/MGPS Booster Pumps are the most durable booster pump available. The proven SignaSeal floating impeller design minimizes thrust loads allowing for continuous operation without damage to motor bearings,

More information

Wholesale & Retail - Sales & Service of : Domestic, Commercial & Industrial RO water purifiers

Wholesale & Retail - Sales & Service of : Domestic, Commercial & Industrial RO water purifiers Wholesale & Retail - Sales & Service of : Domestic, Commercial & Industrial RO water purifiers PLANET AQUA - EXCLUSIVE RETAIL SHOWROOM Shop No.10, Sita Park, Naya Nagar, Lodha Road, Mira Road (E), Thane-401107.

More information

GE WATER & PROCESS TECHNOLOGIES E-CELL STACK MK-2 SERIES OWNER S MANUAL

GE WATER & PROCESS TECHNOLOGIES E-CELL STACK MK-2 SERIES OWNER S MANUAL GE WATER & PROCESS TECHNOLOGIES E-CELL STACK MK-2 SERIES OWNER S MANUAL 2006, General Electric All rights reserved. No part of this publication may be reproduced, stored in a retrievable system, or transmitted,

More information

IsoTherm FlowGuards Mini Ball Valves Gauges Aquastats Unions

IsoTherm FlowGuards Mini Ball Valves Gauges Aquastats Unions 82 IsoTherm FlowGuards Mini Ball Valves Gauges Aquastats Unions 83 Adjustment knob (sets supply temperature) Mixing Valve 1 Male BSP Threads Mixing Point Supply Inlet from Boiler Temperature Gauge (indicates

More information

M O D E L S E S T / E S T T A L L PARTS MANUAL Rev 1.08 C M A D I S H M A C H I N E S K N O T T S T R E E T GARDEN GROVE, CALIFORNIA 92841

M O D E L S E S T / E S T T A L L PARTS MANUAL Rev 1.08 C M A D I S H M A C H I N E S K N O T T S T R E E T GARDEN GROVE, CALIFORNIA 92841 M O D E L S E S T / E S T T A L L PARTS MANUAL Rev 1.08 C M A D I S H M A C H I N E S 1 2 7 0 0 K N O T T S T R E E T GARDEN GROVE, CALIFORNIA 92841 800-8 54-6 4 1 7 FAX 714-895-2141 www.cmadishmachines.com

More information

THE WATER EQUIPMENT SPECIALIST EST. 2000

THE WATER EQUIPMENT SPECIALIST EST. 2000 Company profile Wilcare water system started as a full time water refilling station in Valenzuela city using it s own water equipment build and assembled by it s owner Mr. Wilson Kie on the year 2000 mastering

More information

See Water Pressure Reducing Valves Catalog (PHBRWPRV) for more detailed information about the products in this section.

See Water Pressure Reducing Valves Catalog (PHBRWPRV) for more detailed information about the products in this section. See Catalog (PHBRWPRV) for more detailed information about the products in this section. Water pressure reducing valves PR (36LF) Series Residential and commercial applications The Apollo 36LF pressure

More information