AQUASTAR C6. (Comfort 6000) Next Generation Auto Backwash Valve System. (selectable time-pressure or remote cycle start)
|
|
- Gervais Lloyd
- 5 years ago
- Views:
Transcription
1 AQUASTAR C6 (Comfort 6000) Next Generation Auto Backwash Valve System (selectable time-pressure or remote cycle start) SIDE MOUNTED AND TOP MOUNTED VALVES WITH QUICK INSTALL ELECTRIC ACTUATORS FOR PIPE SIZES 1.5" - 3 MAX FLOW RATES UP TO 340 USGPM MAX PRESSURE 50PSI MULTIPLE TANK SYSTEMS - MASTER/SLAVE TANDEM LOGIC PROVIDED PLC "PROGRAMMABLE LOGIC CONTROL" MODELS AVAILABLE IN ALL SIZES/STYLES (see separate brochure) MADE IN NORTH AMERICA certified acc. to EN ISO 9001:2000
2 MULTI-VOLTAGE SMT CIRCUITRY TECHNOLOGY allows voltage operation of AC and DC voltage, VAC and VDC (50-60 Hz) Integrated emergency valve handle allows a 1 minute switch over to manual operation Handle incorporates socket wrench for servicing BACKWASH CYCLE RELEASE can be initiated with the following standard installed devices: A Pressure sensing in system 6-95 psi Installed pressure tube Connected to electronic transmitter board Adjustable with circuit board mounted pressure selector switch Green pressure sensing LED for visual activation confirmation B Remote activation by other controller: An integrated external cycle start option allows other equipment such as controllers, manual switches, relays, etc. to start the backwash cycle. Closing a provided 6 VDC control circuit on the circuit board will initiate cycle start
3 C Timer controlled C1 Digital time clock for flexible time controlled backwash releases (up to 25 cycles per day, minimum one per week!) Timer has a battery powered back up power supply. C2 Basic switch timer with 3 release settings: daily, weekly, bi-weekly Off 3 Days 7 Days 14 days Digital time clock Dip switch timer D Pushing the test button on the Touch Pad switch face test button with LED light TIMING OF BACKWASH, RINSE, FIREMAN DELAY duration can be easily field adjusted with board mounted analog dial timers Back wash duration: 50 sec to 9 min Rinse duration: 25 sec to 200 sec Fireman delay duration: 20 sec to 25 min Fireman delay (20 sec to 25 min) is typically used to shut heaters down when the Aquastar controller receives the signal to go into back wash mode. The integrated relay signal will shut down the heater (if connected to the Aquastar relay). That delay time will allow the heater pipes to cool off before the system goes into back wash mode. It is also used to switch on/off chemical feed pumps for duration of backwash and rinse action (thru terminals 21-22). EXTERNAL TOUCH PAD FUNCTIONS provided by a water and steam tight membrane touch pad switch panel with LED indicator lights Touch Pad functions: Test Button: will start a back wash cycle upon being switched on ON: will switch control circuits on OFF: will switch control circuits off DRAIN: will make system go into drain position for lowering water levels and/or for vacuuming direct to waste Press Drain and Test simultaneously for 5 seconds will start the actuator to move into Recirculation position which is a filter bypass position. This is typically used for servicing or troubleshooting.
4 RELIABILITY BY 25 PLUS YEARS field tested circuitry and mechanical components: A Inductive sensors on circuit board precisely sense actuator positions. B Heavy duty drive train motor with steel gear drive and permanently lubricated high strength thermo set gear. Inductive sensor Motor C Permanently self lubricated thermo set main gear with lifting track perfectly centered on stainless steel ball bearings Main gear Lifting track in main gear for roller bearings of lifting cam Lifting cam with three roller bearings and magnetic indicator D Spring cushioned pressure flex compensation. Stainless steel springs compensate for the possible flexing of the valve cover in higher pressure applications and guarantee mechanical stress free operation of the actuator drive unit. Stainless steel springs PUMP INTERLOCK LOGIC The Aquastar controller requires that pump is interlocked at all times through provided relay contacts #13 and #14. An internal mechanical pump limit switch will release the signal for the main pump control circuits upon actuator travel completion. That switch will also interrupt the pump control circuit during actuator travel. Integrated control logic and provided relay contact allow for external 3 way valve or by pass valve controls if the main filter pump cannot be switched off at all. Pump limit switch activated by cam or gear (not shown) VISUAL ACTUATOR POSITION INDICATION for all positions Filter Waste Backwash Recirculate Rinse Drain
5 AQUASTAR C6 Dimensions Aquastar C 6 1.5" and 2" SM Aquastar C 6 3" SM Aquastar C 6 1.5" TM 1.5" SM 1.5" TM 2" SM 3" SM A B C D E F G H I J K L M N O P 2.46 Dimensions in inches Line Neutral MASTER-SLAVE interlock wiring schematic for sequential backwash signal release MASTER VALVE MASTER VALVE SLAVE VALVE MASTER-SLAVE pump interlock schematic SLAVE VALVE coil pump 1 1/2 " SM FLOW RATE (GPM) APP'X HEAD LOSS (PSI) " SM FLOW RATE (GPM) APP'X HEAD LOSS (PSI) " SM FLOW RATE (GPM) APP'X HEAD LOSS (PSI)
6 Sequence of automatic backwash cycle Internally Requires touch pad controlled relays activation Trigger of Delay Cycle Travel* Back Travel* Rinsing Travel* FILTER DRAIN RECIRC. back wash Time Start 45 sec Washing 35 sec 25 s s. 25 sec position position position cycle 25 s. -25 m. 50 s. - 9 m. A 13/14 max 8 contacts contacts contacts contacts contacts contacts contacts contacts contacts contacts contacts Amp closed/ closed/ open / open / closed/ open / pump closed/ open / pump closed/ closed/ closed/ pump on pump on pump off pump off pump on off pump on off pump on pump on pump on B AQUASTAR C6 RELAY SEQUENCING CHART 4/G/3 max 8 Amp G-4 closed G-4 closed G-4 closed G-4 closed G-4 closed G-4 closed G-4 closed G-4 closed G-3 closed G-4 closed G-3 closed C 26/27 contacts contacts contacts contacts contacts contacts contacts contacts contacts contacts contacts max 4 Amp open open open open closed open open open open open open D 24/25 contacts contacts contacts contacts contacts contacts contacts contacts contacts contacts contacts max 4 Amp open open open open open open closed open open open open E 29/30 contacts contacts contacts contacts contacts contacts contacts contacts contacts contacts contacts max 4 Amp open open open open open open open open open open closed F 31/32 contacts contacts contacts contacts contacts contacts contacts contacts contacts contacts contacts max 4 Amp open open open open open open open open open closed open G 21/22 contacts contacts contacts contacts contacts contacts contacts contacts contacts contacts contacts max 4 Amp open / open / open / open / open / open / open / open / closed / open / open / heater off heater off heater off heater off heater off heater off heater off heater off heater on heater off heater off H 18/19/20 max 19/20 closed 4 Amp serial signal will connection of start second multiple Aqua 19/20 19/20 18/19 18/19 18/19 18/19 18/19 18/19 actuator 19/20 19/20 Stars closed closed closed closed closed closed closed closed cycle closed closed * that column represents actuator travel between positions ROW A: Pump interlock control relay Terminals 13 and 14. It shows the switching state of relay during entire backwash cycle. ROW B: SPDT relay state during entire back wash cycle. This is typically used to control 3-Way valves. ROW C: Relay terminals are closed on the backwash position. It is therefore ideally suited for controlling extra equipment in backwash position only. ROW D: Relay terminals are closed in RINSE position. It is therefore ideally suited for controlling auxiliary equipment in Rinse position only. ROW E: Relay terminals are normally open. These relay contacts are N/C only in RECIRCULATION (FILTER BYPASS mode) positions. ROW F: Relay terminals are normally open. These relay contacts are only closed in the DRAIN position. ROW G: Relay terminals are normally open. These contacts are N/C in filter mode. This relay is typically used to control pool heater shut down. ROW H: The sequencing relay terminals of relay 19/20/18 which is a SPDT relay, is typically used for multiple valve sequencing such as initiating a secondary Aquastar controller to start a backwash cycle after the present valve has completed it's cycle. Column 1: Switching positions of all relays while the actuator is receiving the signal from either a pressure switch or other sources (timers) to start the backwash cycle. Column 2: Switching positions of all relays while the internal fireman delay timer (20 sec to 25 min) is counting down to zero to release the cycle start. Column 3: Switching positions of all relays when the cycle start signal is being released in the controllers electronics. A 30 second start delay holds back the motors from moving at this point. Column 4: Switching positions of all relays while the actuator is travelling from FILTER position to BACKWASH position. 25 second duration. Column 5-9: Shows rest of automatic cycle. PRAHER VALVES LTD. 101 Saunders Road, Barrie, ON L4N 6E7 Canada Tel: Fax: US SALES & MARKETING: Tel: Fax:
Always on the safe side. Made in Austria/Europe.
Always on the safe side Made in Austria/Europe. www.peraqua.com The original series by Praher ensures constant and automatic pool filter purification to guarantee optimal hygiene of the pool water. Four
More informationTo ensure proper installation, digital pictures with contact information to before startup.
Check List for Optimal Filter Performance [ ] There should be no back-pressure on the flush line. A 1 valve should have a 2 waste line, and 2 valve should have a 3 waste line. Do not use rubber hosing
More informationXCITE Owner s Manual. Reso-not TM Damping System XCITE 1502C HYDRAULIC POWER SUPPLY
Reso-not TM Damping System XCITE Owner s Manual 1502C HYDRAULIC POWER SUPPLY Xcite Systems Corporation 675 Cincinnati RDS Batavia - 1 Pike Cincinnati, Ohio 45245 Tel: (239) 980-9093 Fax: (239) 985-0074
More informationPRESSURE GAGES AND TEST TAPS
CAT 500.1 FRF series filters. Polyglass 100 psi vessels with top mount Task Master II 1 ½ valve and single point PVC internals. FMF series filters. Carbon steel epoxy lined and coated vessels with side
More informationInstallation and Operations Manual
Excalibur Water Systems 3.0 High Capacity Superflow Series QUADPLEX Water Softener Installation and Operations Manual 142 Commerce Park Drive, Units M-O, Barrie ON L4N 8W8 www.excaliburwater.com Water
More informationDIESEL Engine Fire Pump Controllers Features
1-1 Printer / Recorder The industrial grade thermal printer is housed in a rugged steel enclosure within the controller. The on/off switch, feed and reset buttons are front accessible. A bi-color status
More informationElectric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 inch NPT
Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 inch NPT SERIES Features Full Port 16 Stainless Steel ball valve LED light gives continuous status indication IP67 weatherproof polyamide
More informationElectric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 inch NPT
Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 inch NPT SERIES Features Full Port 16 Stainless Steel ball valve LED light gives continuous status indication IP67 weatherproof polyamide
More informationElectric Actuated Ball Valves 3-Piece Stainless Steel, Full Port 1/4 to 3 inch NPT
Electric Actuated Ball Valves 3-Piece Stainless Steel, Full Port 1/4 to 3 inch NPT SERIES Features Direct mount Full Port 316 Stainless Steel ball valve 3-piece swing out body designed for easy maintenance
More informationREVISION HISTORY REVISION HISTORY
FILTER CONTROLLER REVISION HISTORY Filter Flush Controller forms part of the Netafim range of filtration controllers all designed to make filteration more reliable and economical.. Contact any of the Netafim
More information3200NT Timer Service Manual
Service Manual Valve Serial Number Valve Position 1-LEAd 2-LAg 3-LAg 4-LAg IMPORTANT: Fill in pertinent information on page 3 for future reference. Table of Contents Job Specifications Sheet.....................................................................
More informationElectric Actuated 3-Way Ball Valves L-Port, PVC Body, Teflon/EPDM Seals 1/2 to 2 inch Pipe
Electric Actuated 3-Way Ball Valves L-Port, PVC Body, Teflon/EPDM Seals 1/2 to 2 inch Pipe SERIES Features Industrial grade PVC ball valve with PTFE/EPDM seals IP67 weatherproof polyamide enclosure with
More informationProgrammable Logic Controller. Mat Nor Mohamad
Programmable Logic Controller Mat Nor Mohamad Relays Electromagnetic Control Relays The PLC's original purpose was the replacement of electromagnetic relays with a solid-state switching system that could
More informationUpdated: October 2012
T: (630) 794-5100 EMERGENCY POWER FUEL SYSTEMS Earthsafe Systems, Inc. 7320 S. Madison Willowbrook, IL 60527 F: (630) 794-5106 info@earthsafe.com www.earthsafe.com Updated: October 2012 The information
More informationTekleen GB6 & GB7 USERS AUTOMATIC FILTERS, INC. MANUAL
AUTOMATIC FILTERS, INC. 67 S. LA CIENEGA BLVD. LOS ANGELES, CA 90034 30 839 88 800 336 94 FAX 30 839 6878 www.tekleen.com info@tekleen.com Tekleen GB6 & GB7 USERS MANUAL GB6 & GB7 USERS MANUAL AUTOMATIC
More informationElectric Actuated Ball Valves 150 lb Flanged Stainless Steel, Full Port 1/2 to 4 inch Pipe Sizes
Electric Actuated Ball Valves 150 lb Flanged Stainless Steel, Full Port 1/2 to 4 inch Pipe Sizes SERIES Features Direct mount Full Port 16 Stainless Steel ball valve 2-piece ANSI Class 150 flanged body
More informationSuggested list for the Hydraulic and Pneumatic lab Instruments Mechatronics Engineering Department School of Applied Technical Science
Suggested list for the Hydraulic and Pneumatic lab Instruments Mechatronics Engineering Department School of Applied Technical Science Pneumatic and Electro-pneumatic components: No. EQUIPMENTS operating
More informationElectric Actuated 3-Way Ball Valves T-Port, Stainless Steel, Full Port 1/4 to 2 inch NPT
Electric Actuated 3-Way Ball Valves T-Port, Stainless Steel, Full Port 1/4 to 2 inch NPT SERIES Features Full Port 316SS diverter valve Polyamide IP67 weatherproof enclosure with UV protection Multi-voltage
More informationSeries Electric Actuators
Electric Actuators Electric Actuators Series 44000 Electric Actuators ELECTRIC ACTUATORS With maintenance-free operation, the Crane 44000 electric actuator is ideal for small to medium diameter valves
More informationINSTALLATION GUIDE. FCC ID NOTICE
REV.5 RS. ADVANCED REMOTE STARTER INSTALLATION GUIDE www.security.soundstream.com FCC ID NOTICE This device complies with Part 5 of the FCC rules. Operation is subject to the following conditions:. This
More informationGCU-10. Automatic Engine Control Unit Operators Manual
GCU-10 Automatic Engine Control Unit Operators Manual KUTAI ELECTRONICS INDUSTRY CO., LTD. TEL : +886-7-8121771 FAX : +886-7-8121775 Website : www.kutai.com.tw Headquarters : No.3, Lane 201, Chien Fu St.,
More informationHorizontal Circuit Switchers
> Transformer Protection > CIRCUIT SWITCHERS C A T A L O G B U L L E T I N General Application Southern States Types CSH and CSH-B Horizontal Circuit Switchers provide an economical, versatile, space saving
More information2 WAY REMOTE STARTER & ALARM SYSTEM INSTALLATION GUIDE FCC ID NOTICE
REV. ARS. WAY REMOTE STARTER & ALARM SYSTEM INSTALLATION GUIDE FCC ID NOTICE This device complies with Part 5 of the FCC rules. Operation is subject to the following conditions:. This device may not cause
More informationECU-02 Ver2.1 Automatic Engine Control Unit Operators Manual
ECU-02 Ver2.1 Automatic Engine Control Unit Operators Manual Headquarters : No.3, Lane 201, Chien Fu St., Chyan Jenn Dist., Kaohsiung, TAIWAN Tel : + 886-7-8121771 Fax : + 886-7-8121775 URL : http://www.kutai.com.tw
More informationE Series Electric Actuators
ENGINEERING MANUAL 13560 Larwin Circle, Santa Fe Springs, CA 90670 Phone: (562) 802-2255 (800) 783-7836 Fax: (562) 802-3114 Netsite: www.svf.net E-mail: Sales@SVF.net E Series Electric Actuators 1/4 3
More informationARCHITECTURAL DOOR HARDWARE POWER SUPPLIES & TRANSFORMER CATALOG
ARCHITECTURAL DOOR HARDWARE POWER SUPPLIES & TRANSFORMER CATALOG January 1, 2017 v3 West Coast Office (800) 544-4422 East Coast Office (800) 225-6737 intldoorclosers.com Index POWER SUPPLIES & TRANSFORMERS
More informationAQT-56SE ELECTRONIC SERIES PROGRAMMING MANUAL CONTROL VALVES
AQT-56SE ELECTRONIC SERIES PROGRAMMING MANUAL TABLE OF CONTENTS General Residential Installation 3 AQT-56SE Keypad 4 Control Operation 5 Master Programming - Setting the Time of Day 6 - Setting the Regeneration
More informationGate & Door Controller with LCD and Intelligent Technology
2nd Edition Gate & Door Controller with LCD and Intelligent Technology 24Sv1 and 12Sv1 Motor Controllers Setup and Technical information for single motor controller for gates & doors Includes latest Intelligent
More informationAUTO-EC-3-E-PLC Electric Filter Backwash Controller Operation & Maintenance Manual
AUTOEC3EPLC Electric Filter Backwash Controller Operation & Maintenance Manual Contents Contents Controller Basics 3 Controller Components 4 Screen Flow Diagram Controller Functions 6 Installation 7 Warranty
More informationPARKING LOT CONTROLLER WITH LOGIC & MAIN CONTACTOR
PARKING LOT CONTROLLER WITH LOGIC & MAIN CONTACTOR VPC-AA The VPC-AA Parking Lot Controller is an easily installed device designed for mid-sized parking lot installations. The weather proof design is ideal
More informationELECTRICAL SYSTEM RP-7
ELECTRICAL SYSTEM RP-7 This section of the manual does not include integral electrical components of the engine. Refer to section Engine RP-1 for details. This section of the manual is divided into three
More informationArch HTH Water Chemicals Commercial Equipment Trouble Shooting Guide
Arch HTH Water Chemicals Commercial Equipment Trouble Shooting Guide 8/28/00 TROUBLESHOOTER S GUIDE PROBLEM CAUSE SOLUTION Insufficient water flow to chlorinator Check water flow through Flow Controller
More informationOptimal Series. Automatic Transfer Switch. Installation and User Manual for the OPT2225 Automatic Transfer Switch. Full Version
Optimal Series Automatic Transfer Switch Installation and User Manual for the OPT2225 Automatic Transfer Switch Full Version File: OPT2225 Rev2.5.doc November, 2004 2 Thank You For Purchasing This DynaGen
More informationSALES PRESENTATION FOR RELAYS, CONTACTORS & MOTOR STARTER TESTING EQUIPMENTS
SALES PRESENTATION FOR RELAYS, CONTACTORS & MOTOR STARTER TESTING EQUIPMENTS Relay Test Bench: LIST OF TEST EQUIPMENT 1. FIVE STATION BIMETAL OVERLOAD RELAY TEST BENCH 2. TWENTY FOUR STATION RELAY HEATING
More informationTransfer switch GTEC open or delayed transition
Transfer switch GTEC open or delayed transition 40-1250 Amp Description The GTEC automatic transfer switch combines reliability and flexibility in a small, economical package for transferring loads between
More informationAquaMatic Series. A100 and A200 Stager Controls
AquaMatic Series A100 and A200 Stager Controls 2 Table of Contents Introduction To AquaMatic Series A100 and A200 Stager Controls3 Specifications 4 Applications 5 Features 6 Cycle Time Programming 7 Setting
More informationPower Supplies DORMA PS
Power Supplies DORMA PS DORMA PS Power Supplies Main System On/Off or Fire Panel Relay - The power supply output voltage can be controlled by the main system on/off control relay which accepts a closed
More informationElectric Actuated Ball Valves 150# Flanged Stainless Steel, Full Port 1/2 to 4 inch Pipe
1/2 to 4 inch Pipe Features Direct mount ISO5211 Full Port stainless steel ball valve 2-piece ANSI Class 150 flanged body 275 PSI working pressure at 100 F (38 C) Highly visual dome style valve position
More informationElectropneumatic Timing Relays Series 7000 Industrial
DESIGN FEATURES Available in On-Delay, True Off-Delay, and On/Off-Delay. Timing from 0.1 seconds to 60 minutes, fully calibrated in linear increments. Oversize time-calibrated adjustment knobs, serrated
More informationHorizontal Circuit Switchers
> Transformer Protection > CIRCUIT SWITCHERS C A T A L O G B U L L E T I N General Application Southern States Types CSH and CSH-B Horizontal Circuit Switchers provide an economical, versatile, space saving
More informationMount directly to 1.05 jackshafts. (new ZG-120 bracket shown) EFB24-S N4, EFX24-S N4(H) EFB24-S, EFX24-S (p. 21)
EFB and EFX Series Spring Return Direct Coupled Actuator Minimum 70 in-lb Torque For damper areas up to 66 sq-ft* (For lower torque, see AFB, AF, NFB, LF, or TF series) Applications New standard clamp
More informationTECHNICAL PAPER 1002 FT. WORTH, TEXAS REPORT X ORDER
I. REFERENCE: 1 30 [1] Snow Engineering Co. Drawing 80504 Sheet 21, Hydraulic Schematic [2] Snow Engineering Co. Drawing 60445, Sheet 21 Control Logic Flow Chart [3] Snow Engineering Co. Drawing 80577,
More informationQ&A FOR Webinar on Electrical Basics & Boiler Wiring
Q&A FOR Webinar on Electrical Basics & Boiler Wiring 4-20-16 Q: Is a dual fuel burner flame guard system more complicated than the one you showed us today? A: Not really. If the boiler is equipped for
More informationWIRING / CONNECTION GUIDE (20-PIN) SECONDARY CONNECTOR
EVO-ONE WIRING / CONNECTION GUIDE (20-PIN) SECONDARY CONNECT (6-PIN) BYPASS RELAY (+) Foot Brake Black IN 750mA (-) Parking lights Pink OUT 750mA (-) Trunk Release/AUX Yellow/Black OUT (-) Hand Brake Brown/
More informationPNEUTRAINER-200 Pneumatics - Electro-pneumatics
PNEUTRAINER-200 Pneumatics - Electro-pneumatics End-to-end solution for training in pneumatics and electro-pneumatics. www.smctraining.com training@smctraining.com 46 Develop the SKILLS... Analysis Troubleshooting
More informationV200 V200. Control on water, proportional integral. Simplified Master / Slave operation GENERAL DESCRIPTION
Master Slave 1 Slave (n + 1) Master Slave 1 Slave (n + 1) Simplified Master / Slave operation GENERAL is a CIAT electronic control system designed to control non-independent air conditioning terminal units
More informationRated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications
WPC-1 Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications Installation Instructions: Read these instructions in their entirety before performing any installation work. FOR USE WITH POOL AND
More informationElectric Actuators Maximum in-lbs
Maximum 14040 in-lbs NEMA 4, 4X, 7 ER- Series Features ISO / DIN valve interface Mounting in any position Thermal overload protection (AC & DC except 12 VDC) Friction brake (standard for AC motors except
More informationU S A INSTALLATION GUIDE EP400 / E8-B
U S A INSTALLATION GUIDE EP400 / E8-B www.easycar-.com Before Beginning the Installation 1. Wire Connection Guides Please read this entire installation guide before beginning the installation. The installation
More informationActuated Valves PRICING
Electric & Pneumatic Actuated Valves Actuated Valves PRICING Page Suitable for Oil-Free air handling to 5 psi, not for distribution of compressed air or gas Spears Manufacturing Company Due to Material
More informationSECTION MOTOR CONTROL
SECTION 26 24 19 MOTOR CONTROL PART 1 - GENERAL 1.1 SECTION INCLUDES A. Manual motor starters B. Magnetic motor starters C. Combination magnetic motor starters D. Solid-state reduced voltage motor starters
More informationElectric Actuators Maximum in-lbs
Maximum 14040 in-lbs NEMA 4, 4X, 7 ER- Series Features ISO / DIN valve interface Mounting in any position Thermal overload protection (AC & DC except 12 VDC) Friction brake (standard for AC motors except
More informationLt.Blue/Black. White. Orange. LED Blue LED Yellow LED Red
EVO-ONE RFK1004 WIRING / CONNECTION GUIDE (20-PIN) SECONDARY CONNECT (6-PIN) BYPASS RELAY (+) Foot Brake Black IN 750mA (-) Parking lights Pink OUT 750mA (-) Trunk Release/AUX Yellow/Black OUT (-) Hand
More informationReproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.
SERVICE MANUAL ELECTRIC BRAISING PANS (30 & 40 GALLON) VE30 VE40 ML-126849 ML-126850 VE40 SHOWN - NOTICE - This Manual is prepared for the use of trained Vulcan Service Technicians and should not be used
More informationTransfer switch OTEC open or delayed transition
Transfer switch OTEC open or delayed transition 40-1000 Amp Description OTEC transfer switches are designed for operation and switching of electrical loads between primary power and standby generator sets.
More informationOPERATING INSTRUCTIONS MCP-MT1
OPERATING INSTRUCTIONS MCP-MT1 MRM PROCOM Pvt Ltd ISO-9001-2008 certified organization Plot No. : 20-21, Industrial Estate, Sector - 59, Phase-II, Faridabad (Haryana) Ph.: 0129-4700400(10 Lines) Email:
More informationBest Diversified Products, Inc. Product Manual. BestReach Rigid Belt. Models BRB 230 OS BRB 230 SS BRB 460 OS BRB 460 SS
Best Diversified Products, Inc. Product Manual TM BestReach Rigid Belt Models BRB 230 OS BRB 230 SS BRB 460 OS BRB 460 SS Best Diversified Products Inc. 107 Flint Street Jonesboro, AR 72401 Phone 870-935-0970
More informationINOVA HIGHTECH Ltd. MEP 002/003 Auto Starter Manual
INOVA HIGHTECH Ltd. MEP 002/003 Auto Starter Manual Complete Installation and Operating Manual for the MEP 002/003 Auto / Remote Starter for the following MEP Power Generators: MEP 002A/003A/011A/802A/803A/811A
More informationWARNING. Diode Package The Murphy diode package ( ) is designed to allow the fuel shutoff valve to be used with dual Magneto Ignition systems.
M2582, M508, and M580 Series Electromechanical and Pneumatic, Fuel Gas Shutoff Valves Installation and Operation Instructions Please read the following instructions before installing. A visual inspection
More informationECO3-601/602 EcoStar III * Chevy Express/GMC Savana Contact Intermotive for additional vehicle applications
An ISO 9001:2015 Registered Company ECO3-601/602 EcoStar III 2009-2019* Chevy Express/GMC Savana Contact Intermotive for additional vehicle applications * In 2017-2018, the ignition switches on Chevy Express
More informationMD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version
MD10 Engine Controller Installation and User Manual for the MD10 Engine Controller. Full Version File: MartinMD10rev1.4.doc May 16, 2002 2 READ MANUAL BEFORE INSTALLING UNIT Receipt of shipment and warranty
More informationPATTERSON PUMP COMPANY
PATTERSON PUMP COMPANY A Gorman Rupp Company JOCKEY PUMP CONTROLLERS UL508 LISTED ETL LISTED FEB 013 Patterson Jockey Pump controllers are built to NEMA industrial standards and are UL508 listed and ETL
More informationProduct Specification Guide. Title: Southern States 72 kv RLSwitcher Vertical Interrupter Style Reactor Switcher
TABLE OF CONTENTS PAGE 1.0 SCOPE... 2 2.0 STANDARDS... 2 3.0 DESIGN REQUIREMENTS... 2 3.01 Service Conditions... 2 3.02 Ratings... 3 3.03 Interrupter... 3 3.04 SF6 Gas System... 4 3.05 Terminal Pads...
More informationMount directly to 1.05 jackshafts. AF230 US (p. 02) AF230-S US (p. 20) AF24-S US (p. 18)
AF Series Spring Return Direct Coupled Actuator Minimum 133 in-lb torque For damper areas up to 35 sq-ft* (For lower torque, see NF, LF, or TF series) Applications Remove for 3/4 to 1.05 shafts ZG106 or
More informationLevalarm Gold. Installation, Operation, & Maintenance Instructions R500.E253A 03/16/2016
Installation, Operation, & Maintenance Instructions R500.E253A 03/16/2016 Levalarm Gold STORAGE AND HANDLING The Reliance Levalarm Gold meets or exceeds all applicable specifications when shipped from
More information7000 series. Industrial Electropneumatic Timing Relay AGASTAT. Design Features. On-delay model 7012 (delay on pickup) Design & Construction
7000 series Industrial Electropneumatic Timing Relay File E15631 File LR29186 Note:7032 types and certain models with accessories are not agency approved. Users should thoroughly review the technical data
More informationAC Rectifiers for use with Armature Actuated Brakes. Product Overview. Full Wave. Half Wave. Combination Full and Half Wave. TOR-AC Full and Half Wave
Rectifiers for use with Armature Actuated Brakes Product Overview NOTE: For brake response times with and without rectifiers see page 94. Full Wave A rectifier in which both positive and negative half-cycles
More information200C II BRAKE SYSTEM
200C II BRAKE SYSTEM The braking system on the 200C II Kress Coal Hauler uses hydraulic oil pressure from both the System and Steering accumulator circuits. Using oil from both circuits provides braking
More informationElectrical: Valve monitoring and control circuits
Electrical: Valve monitoring and control circuits Valve monitoring and communication Electrical: valve monitoring and control circuits Overview This section covers valve monitoring circuits for interfacing
More informationElectro Pneumatic WorkStation Scientech 2470
Electro Pneumatic WorkStation is designed to demonstrate the design, construction and application of Pneumatic components and circuits. It integrates PLC technology to build Hybrid Industrial Automation
More informationB100S - Super Swing. Instruction Manual. Document number: B100S-C Release: V4.0 Date: May 08,2009
B00S - Super Swing Instruction Manual Document number: B00S-C Release: V4.0 Date: May 08,009 ! WARNING This control must be adjusted/serviced by a qualified person. The service technician must be familiar
More informationCompact Electric Actuated 3-Way Ball Valves T-Port, 316 Stainless Steel, Full Port 1/4 to 3/4 NPT
Compact Electric Actuated 3-Way Ball Valves T-Port, 316 Stainless Steel, Full Port 1/4 to 3/4 NPT Features Industrial quality miniature actuator Full Port direct mount 3-way stainless steel ball valve
More informationRated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications
WPC1-XXXX-T Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications Installation Instructions: Read these instructions in their entirety before performing any installation work. FOR USE WITH
More informationAtlas Automotive. Equipment. Electro-Mechanical. Design Features
Atlas Automotive Equipment Electro-Mechanical Mobile Column Lifts MC7000 MC9000 MC12000 MC16000 MC19000 MC22500 Design Features 6 Models with Capacities Ranging from 7000 lb. to 22,500 lb. per Column 3
More informationSuper-Safe-Plus Roto-Bin-Dicator
Super-Safe-Plus Roto-Bin-Dicator for your most demanding applications... Offers both mechanical and electronic sensing in one reliable Point Level Sensor... Level control with added confidence Under normal
More informationRADIO FREQUENCY SYSTEMS
C14520.016-E.MU0 DOC.:10000008168-02 LAB4 DEHYDRATOR USER MANUAL 1 DRYING CHAMBER 2 HEATER 3 PUMP 4 AIR BACKWASHING HOLE 5 HUMIDITY PROBE 6 DIGITAL PRESSURE GAUGE 7 RELIEF VALVE 8 SHUT OFF VALVE 9 DRY
More informationFSAF24(-S) US, FSAF120(-S) US
FSAF4(-S) US, FSAF10(-S) US On/Off, Spring Return, Meets 50 F [11 C] for Half Hour, 75 Seconds Torque min. 133 in-lb, for control of air dampers Technical Data FSAF4(-S) US, FSAF10(-S) US Power supply
More informationPIPING PACKAGES For Chilled and Hot Water Fan Coil Units
WWW.KRUEGER-HVAC.COM PIPING PACKAGES For Chilled and Hot Water Fan Coil Units PROVIDING YOU WITH AIR DISTRIBUTION AND EQUIPMENT SOLUTIONS TABLE OF CONTENTS General Notes... 4 Code Descriptions... 5 Guide
More informationINSTRUMENTATION & CONTROL
Irrigation Controller.................... 172 Window Controller.................... 174 Water Meter Controller.................. 176 Digital Level Switch.................... 177 Filtration Controller Set..................
More informationRESISTIVITY MONITOR/CONTROLLERS
RESISTIVITY MONITOR/CONTROLLERS Installation Operation Maintenance User Manual for Models: 750, 752, 753, 762 2450 Impala Drive Carlsbad, CA 92010-7226 USA Tel: 1-760-438-2021 Fax: 1-800-869-7668 / 1-760-931-9189
More informationElectro Pneumatic Workbench Scientech 2470
Scientech 2470 Electro Pneumatic Workbench is designed to demonstrate the design, construction and application of Pneumatic components and circuits. It integrates PLC technology to build Hybrid Industrial
More informationEuclid Full Voltage Magnet Controller
Hubbell Industrial Controls, Inc. Euclid Full Voltage Magnet Controller Instruction & Renewal Parts Manual Instructions/Parts Manual Publication No. 180 Replaces Sept. 1991 4291 & 4295/ 96 Type 4291 Type
More informationCSI-400 Installation Instructions
CSI-400 Installation Instructions Kit Contents Installation Precautions: Roll down window to avoid locking keys in vehicle during installation Avoid mounting components or routing wires near hot surfaces
More informationREVISED ATM72 Auto Transfer Module
Capricorn Controls DA01ATM1-1 Data & Application Note Page 1 of 8 REVISED - - - ATM72 Auto Transfer Module Genset Controls - Timers - Monitors - Trips - Battery Charging - Spares & Accessories - Custom
More informationTroubleshooting Guide
Troubleshooting Guide P/N 0153180 July 1999 P.O. Box 1160 St. Joseph, MO 64502-1160 1-800-255-0317 Fax: 816-360-9379 www.snorkelusa.com GENERAL INFORMATION This manual contains procedures for locating
More informationTransfer switch OTEC and OTECSE open transition
Specification sheet OTEC and OTECSE open transition 125-600 Amp Description OTEC transfer es are designed for operation and ing of electrical loads between primary power and standby generator sets. They
More informationDesign Envelope Booster Systems. Design Envelope Booster Systems. FILE NO: DATE: Feb. 05, 2010 SUPERSEDES: DATE: Jan.
57 574 4 574 573 57 57 57 57 1 571 47 474 4 474 473 47 47 47 47 1 471 56 567 7 565 565 37 374 74 374 7 373 37 37 37 37 1 371 467 6 467 465 465 7 74 4 74 73 7 7 7 7 7 71 71 36 367 7 365 365 6 67 7 65 65
More informationElectric Actuated 3-Way Ball Valves T-Port Diverter, Stainless Steel, Full Port 1/4 to 2 NPT
T-Port Diverter, Stainless Steel, Full Port 1/4 to 2 NPT Features Full Port direct mount 316 SS ball valve Functions as a diverter valve 1000 PSI working pressure at 100 F (38 C) Visual valve position
More informationPNEUTRAINER-400 Pneumatics - Electropneumatics
PNEUTRAINER-400 Pneumatics - Electropneumatics End-to-end solution for training in pneumatics and electro-pneumatics SMC industrial systems components on panel mounting plate Implements and controls pneumatic
More informationElectric Actuator Options & Accessories
The basic options and accessories listed in this section represent many of the most commonly used for electric actuation, factory configured to order on the actuation package. Contact Spears for any desired
More informationCommercial Softeners
Commercial Softeners Product Index Page General System Specifications 35 Fleck Commercial Valve Configurations 36 Fleck 9500 1-1/" Systems 37 Fleck 850 1-1/" Systems 38 Fleck 3150 " Systems 39 Fleck 900
More informationPROCESS & AUTOMATED VALVES
Process & utomated Valves HYDC s line of Process and utomated Valves complements our isolation valve knowhow and ability to supply high quality solutions to your valve requirements. 3-1 HV Series Inline
More informationFlight Systems. Replacement for KASSEC DESCRIPTION
DESCRIPTION The is a universal generator controller that will start, stop, and provide engine protection for most generators. Universal replacement for both the 90353 and 90354 KASSEC Compatible with most
More informationElectric Actuated Butterfly Valves Ductile Iron Wafer Body ANSI/ASME 150 lb 2 to 6 inch Pipe
Electric Actuated Butterfly Valves Ductile Iron Wafer Body ANSI/ASME 150 lb 2 to 6 inch Pipe SERIES Features Wafer butterfly valve with ISO5211 direct mount actuator Unique wave line seat reduces torque
More informationElectric Actuated Ball Valves 3-piece Stainless Steel, Full Port 1/4 to 3 NPT
1/4 to 3 NPT Features Direct mount ISO5211 Full Port stainless steel ball valve 3-piece swing out body designed for easy maintenance 1000 PSI working pressure at 100 F (38 C) Highly visual dome style valve
More informationIn this manual you can find how to connect the valve to a standard electric box from Certikin (point 3) or to a DUAL SPEED electric box (point 4).
1. DESCRIPTION. The BASIC Automatic multiport valve is based on a manual valve with bolts on cover, where fits an electric actuator in order to automate Backwash, Rinse, Filter and Waste functions. This
More informationRain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit
Rain+Birdt Simple To Set r (SST) Setup & Operation Instructions English Installation...2 Tools and Supplies Needed...2 Step 1. Mount r...2 Step 2. Connect Power...2 Indoor r...2 Outdoor r...2 Step 3. Connect
More informationJ1 Plug Pin Identification
D5 D D D D5 D ART_ J D D0 R R R R TB 0 D D D D D D J Plug Pin Identification PIN # WIRE # SIGNAL FUNCTION 0 INPUT Drive Reverse INPUT Drive Forward OUTPUT Brake, Decel Valve signal INPUT Steer Left 5 OUTPUT
More informationMANUAL ELECTRIC FIRE PUMP CONTROLLERS METRON SERIES M450
MANUAL ELECTRIC FIRE PUMP CONTROLLERS METRON SERIES M450 TABLE OF CONTENTS PART I GENERAL DESCRIPTION... PAGE 2 PART II FUNCTIONS... PAGE 2 PART III INSTALLATION... PAGE 3 PART IV INITIAL INSTALLATION
More informationRATE CONTROLLED TORQUE WRENCH TESTER
RATE CONTROLLED TORQUE WRENCH TESTER OPERATOR S HANDBOOK (PART NO. 34078) ISSUE 8 NORBAR TORQUE TOOLS LTD, Beaumont Road, Banbury, Oxfordshire, OX16 1XJ, UNITED KINGDOM Tel : + 44 (0) 1295 270333, Fax
More information