CBP COMBIBOX CONCEPT. Configurations DESCRIPTION OF VENTILATION MODULES

Size: px
Start display at page:

Download "CBP COMBIBOX CONCEPT. Configurations DESCRIPTION OF VENTILATION MODULES"

Transcription

1 CBP COMBIBOX CONCEPT DESCRIPTION OF VENTILATION MODULES The perfect match between dimensional criteria and air handling and acoustic performance. Configurations HORIZONTAL MOUNTING HH HV VH HHV HVH VERTICAL MOUNTING (Factory-configured on request) BD HD BHD APPLICATION Ventilation of premises requiring average and high flow rates. Can be used for air extraction or blowing. s Particularly suited where there are high sound and heat insulation requirements. RANGE Available in 6 sizes and 6 models, the CBP range covers flow rates from to 000 m 3 /h. CONSTRUCTION Structure in aluminium profile. Corners in reinforced polyamide. s Removable and interchangeable panels. RAL 03 pre-lacquered external face with protective film. High density 2 mm MO mineral wool insulation. Internal face in galvanized steel. s Access panel to internal components fitted with a safety latch. s Nuts crimped into the structure for floor/wall/ceiling fixing. s Unit fitted as standard with intake and outlet panels with circular connections and double lip seals. MOTOR FAN Impulse centrifugal turbine with double opening. IP class F motor with belt and pulley coupling and PTO thermal cutout. Drive pulley can be varied when stopped for motors up to. kw. s Motor-fan assembly mounted on chassis fitted with vibration mounts. s Motor on adjustable carriage providing rigid and reliable locking to ensure efficient tensioning of the belt. s Flexible connection from the fan to the air supply panel. BH BDH INSTALLATION s The CBP COMBIBOX CONCEPT range can be used fixed to the floor or vertically against a wall. The interchangeable panels allow for all possible installation configurations. s Can be installed internally or externally (rain cover). s Ground/wall fixing brackets as standard. INSTALLATION AND ELECTRICAL OPTIONS Numerous options are available (See page 0). P94 CALAD I rue de Saint Véran I 000 MÂCON LOCHÉ I Tél. 33 (0) Fax 33 (0) I

2 DIMENSIONS CBP Model CBP Motor Module weight Module Dimensions power CBP size A B C E Ø F without filter (kg) COMBIBOX kw mm mm mm mm mm mm DP CBP 4 DP 2 D 0, CBP 4 DP 2 E, CBP DP 408 B 0, CBP DP 408 C 0, CBP DP 408 D 0, CBP DP 408 E, CBP DP 408 F, CBP 6 DP 08 C 0, CBP 6 DP 08 D 0, CBP 6 DP 08 E, CBP 6 DP 08 F, CBP 6 DP 08 G 2, CBP DP 08 D 0, CBP DP 08 E, CBP DP 08 F, CBP DP 08 G 2, CBP DP 08 H 3, CBP 8 DP 0 F, CBP 8 DP 0G 2, CBP 8 DP 0H 3, CBP 8 DP 0I 4, CBP 9 DP 60 G 2, CBP 9 DP 60 H 3, CBP 9 DP 60 I 4, CBP 9 DP 60 J, PRESELECTION TABLE CBP C P9

3 CBP ACOUSTIC The values Lp4m db (A) ( rejection not connected box. The values cond Lw db (A) ( )shown on the curves correspond to the sound pressure level at 4 m hemispherical free field on a reflective surface, ) indicated on the curves correspond to the total sound power radiated in the upstream duct. To obtain the spectrum of the sound power level Lw cond db (A), upstream side, add the following values to the sound power LW cond db (A) ( ) indicated on the curves either a CBP - DP (Double skin) or CBP - NOR (uninsulated). Upstream acoustic spectrum weighting function cond LwA (db(a)) ( ) shown on the curves Frequency 63Hz 2Hz 20Hz 00Hz 000Hz 2000Hz 4000Hz 0Hz CBP 4 DP 2 db(a) CBP DP 408 db(a) CBP 6 DP 08 db(a) CBP DP 08 db(a) CBP 8 DP 0 db(a) CBP 9 DP 60 db(a) The global acoustic power level shone in the conduit approval " LwA cond refoulemet db(a)" shall be calculated by adding 20 db(a) to the values in "Lp4m db(a)" ( ), indicated on the curves. For the sound pressure level Lp db (A) in a hemispherical free field, at a distance, camera placed on the floor reflecting surface upstream side connected discharge side not connected, add the following values in db Lp4m (A) ( ) indicated on the curves Weighted Lp at various distances depending on Lp4m ( ) Distance 2 m 3 m 4 m m m 0 m Weighting distance db(a) NOTA : Tolerance Values = overall +/- 3 db(a) Acoustic spectrum +/- db(a) For the sound level "NSC4" to 4m, equipment connected to the suction and discharge by a similar sound insulation sheath that the box, subtract 20 db(a) to the values in Lp4m indicated on the curves. REFERENCE GIVEN IN THE ORDER Exemple : CBP 4 DP 2 C4 Module Max. operating range Motor drive: Size m 3 /h maxi C = 0, kw 00 Pa maxi Range Type CB = COMBIBOX of construction Type de moteur : P = Belt and DP = Double-skin insulation 2 mm RAL 03 4 = -speed 4-pole Pulley transmission 48 = 2 speed 4/8 pole DAHLANDER P96 CALAD I rue de Saint Véran I 000 MÂCON LOCHÉ I Tél. 33 (0) Fax 33 (0) I

4 ACOUSTIC CBX.BA Attenuation in db(a) COMBIBOX Module Size Sound power INTAKE side CBX BA UPSTREAM of the CBP module PSA - 0 PSA - 0 PSA - 3 PSA - 2 PSA - 4 PSA - 3 Sound power DISCHARGE side CBX BA DOWNSTREAM of the CBP module PSA - 8 PSA - 8 PSA - PSA - 0 PSA - 2 PSA - PSA: Sound power at unit intake in db(a) shown in the documentation on the curves for CBP modules. Spectra ATTENUATION OF THE ACOUSTIC MODULE, INCLUDING REGENERATION PHENOMENON HZ CBX 4 BA CBX BA CBX 6 BA CBX BA CBX 8 BA CBX 9 BA db db db db db db COMBIBOX CONCEPT comprising: damper which can be motor driven, hot water module with integrated filter, cold water module and ventilation module. CALAD I rue de Saint Véran I 000 MÂCON LOCHÉ I Tél. 33 (0) Fax 33 (0) I P9

5 COMBIBOX SELECTION CURVES SIZE 4 CBP 4 DP tr/mn Static pressure CBP (Pa) D 9 E Additional modules CBX 4 Losses of loads options (Pa) Acoustic module Charcoal module ELECTRICAL COMBIBOX -speed 4-pole motor Motor Rotation Voltage Protection Cos Speed controller pwr. speed () current Supply. 230 V single phase Supply. 400 V three phase (kw) (rpm) (V/phase/Hz) 400V (A) output 230 V three-phase output 400 V three-phase CBP 4 DP D4 0, 690/ /3/0,90 0,4 VFM 0, VFT 0, CBP 4 DP E4,0 90/ /3/0 2,2 0,8 VFM, VFT, () Min./max. rotation speed with standard transmission 2 speed 4/8 pole DAHLANDER motor Motor Rotation () Voltage Protection Cos power speed (V/phase/ current (kw) (tr/mn) Hz) 400 V (A) CBP 4 DP D48 0,/0, 690/ /3/0 2,/,02 0,8/0,63 CBP 4 DP E48,0/0,26 90/ /3/0 2,9/, 0,9/0, P98 CALAD I rue de Saint Véran I 000 MÂCON LOCHÉ I Tél. 33 (0) Fax 33 (0) I

6 PERFORMANCE HEAT MODULES SIZE 4 CBX4 CBX 4 BC Temp. incoming ( C/ C) air ( C) Air flow (m 3 /h) /0 - Puis. (kw)/temp. sortie air ( C) 0,6 / 3, 2, / 26,9 4,6 / 23,4 6,2 / 20,6, / 8,4 9, / 6, 9,8 /,6 Débit eau (l/h)/dp eau (kpa) 40 / 8 0 / 0 / 4 20 / 6 9 / 9 80 / / 23 Puis. (kw)/temp. sortie air ( C) 9, / 36,8,6 / 32,4 3,3 / 29, 4,8 / 26, 6,2 / 24,3,4 / 22, 8,0 / 2, Débit eau (l/h)/dp eau (kpa) 430 / 0 / 9 90 / / 4 20 / 6 0 / 8 / 20 Puis. (kw)/temp. sortie air ( C) 8 / 4,4 9,6 / 4, / 38,6 2,2 / 36,3 3,4 / 34,4 4,4 / 32,8 4,9 / 32, Débit eau (l/h)/dp eau (kpa) 360 / 430 / 490 / 8 40 / 0 90 / 2 0 / / 4 Puis. (kw)/temp. sortie air ( C), / 0, 8, / 46, 9, / 43,8 0,8 / 4,,8 / 40,0 2, / 38, 3, / 3,9 Débit eau (l/h)/dp eau (kpa) 30 / / 430 / 480 / 8 20 / 9 60 / 80 / 80/60 - CBX 4 BF Temp. incoming ( C/ C) air ( C) /2 6/ Evap. temp. ( C) Puis. (kw)/temp. sortie air ( C) 9,4 / 26,,2 / 22 2,9 / 8,9 4,3 / 6,4,6 / 4,4 6,8 / 2,,4 / 2 Débit eau (l/h)/dp eau (kpa) 40 / 6 00 / 9 0 / 630 / / 6 40 / 8 0 / 9 Puis. (kw)/temp. sortie air ( C) 8,4 / 3,2 0, / 2,3,6 / 24,4 2,9 / 22, 4, / 20,3, / 8,,6 / 8 Débit eau (l/h)/dp eau (kpa) 30 /,3 40 / 0 / 9 0 / 620 / 3 60 / 690 / 6 Puis. (kw)/temp. sortie air ( C) 6,8 / 39,6 8, / 36,2 9,3 / 33, 0,3 / 3,,3 / 30, 2, / 28,8 2, / 28,2 Débit eau (l/h)/dp eau (kpa) 300 / / 40 / / 8 00 / 9 40 / 0 0 / Puis. (kw)/temp. sortie air ( C),9 / 44,0 / 4 8 / 38,8 8,9 / 3 9, / 3,6 0,4 / 34,3 0,8 / 33,8 Débit eau (l/h)/dp eau (kpa) 260 / 3 30 / 4 30 / 390 / / 460 / / 8 Air flow (m 3 /h) Puis. (kw)/t. sort. air ( C-%HR) 3,4 / 4,-82 4,4 / 6,4-9, /,-, / 8,8-6, / 9,6-4 6,4 / 20,3-4 Débit eau (l/h)/dp eau (kpa) 80 / 0 / / 0 90 / / / Puis. (kw)/t. sort. air ( C-%HR) 2,6 / 3,9-86 3,3 /,4-3,8 / 6,-82 4,2 /,3-8 4, /,9-80 4, / 8,4-9 Débit eau (l/h)/dp eau (kpa) 440 / 3 60 / 0 / 6 20 / 0 / 8 / 9 Puis. (kw)/t. sort. air ( C-%HR) 2,0 / 3,6-8 2, / - 2,9 /,9-82 3, / 6,6-8 3,3 /,-80 3,4 /,6-9 Débit eau (l/h)/dp eau (kpa) 30 / / / 4 30 / 4 60 / 4 80 / Puis. (kw)/t. sort. air ( C-%HR) 3,6 / 3,8-82 4, /,-9, /,- 6,2 / 8,2-6, / 9-4,0 / 9,8-4 Débit eau (l/h)/dp eau (kpa) 620 / / / 00 / 4 40 / / Puis. (kw)/t. sort. air ( C-%HR) 2,8 / 3,2-86 3,6 / 4,-84 4,2 /,8-82 4, / 6,-8, /,3-80,3 /,9-9 Débit eau (l/h)/dp eau (kpa) 480 / / 20 / 80 / 9 80 / 0 90 / Puis. (kw)/t. sort. air ( C-%HR) 2,3 / 2,9-8 2,9 / 4,3-3,3 /,2-82 3,6 / 6-8 3,8 / 6,6-80 4,0 /,-9 Débit eau (l/h)/dp eau (kpa) 390 / / 4 60 / 620 / 0 / / 6 CBX 4 DX Temp. of incoming air ( C-%HR) Air flow (m 3 /h) Puis. (kw) 3,4 4, 4, 4,6 4,6 4,6 T. sort. air ( C-%HR) 4, , ,- Puis. (kw) 2, 3,3 3,6 3, 3, 3, T. sort. air ( C-%HR) 3,-86,- 6,8-82,8-8 8, Puis. (kw) 2,2 2,6 2,8 2,9 2,9 3 T. sort. air ( C-%HR) 3-8 4, ,9-8,6-9,9- Puis. (kw) 3,8 4,6,2,,, T. sort. air ( C-%HR) 3,2-82,8-9,- 9-20,2-4 20,6-4 Puis. (kw) 3, 3,8 4,3 4,6 4, 4, T. sort. air ( C-%HR) 2,-86 4,2-84,-82 6,9-8,-80 8,-80 Puis. (kw) 2,6 3,2 3, 3, 3, 3, T. sort. air ( C-%HR),6-86 3,- 4,9-82,9-8 6,-80,-80 CBX 4 BE Total Total power in Voltage Weight ELECTROPACK power kw kw per stage V CBX-BE kg type CBX 4 BE 02 2, 2, 230 MONO 30 - CBX 4 BE 03 3, 3, 400 TRI 3 2 TA ou DF* CBX 4 BE 0,, 400 TRI 32 2 TA ou DF* CBX 4 BE 2,2,2 400 TRI 34 2 TA ou DF* *DF if the exhaust fan is controlled by the ELECTROPACK Recap: simplified calculation rule to determine the power of the electrical coil. Flow rate (m 3 /h) x s T ( C) = Power (kw) 3000 P99

7 COMBIBOX SELECTION CURVES SIZE CBP DP tr/mn Static pressure CBP (Pa) B 9 C 4 2 D 80 E F Additional modules CBX Losses of loads options (Pa) Acoustic module Charcoal module ELECTRICAL COMBIBOX P00 -speed 4-pole motor Motor Rotation Voltage Protection Cos Speed controller pwr. speed () current Supply. 230 V single phase Supply. 400 V three phase (kw) (rpm) (V/phase/Hz) 400V (A) output 230 V three-phase output 400 V three-phase CBP DP B4 0,3 90/ /3/0,0 0, VFM 0,3 VFT 0,3 CBP DP C4 0, 30/ /3/0,60 0,6 VFM 0, VFT 0, CBP DP D4 0, 320/ /3/0,90 0,4 VFM 0, VFT 0, CBP DP E4,0 40/ /3/0 2,2 0,8 VFM, VFT, CBP DP F4,0 90/ /3/0 3, 0,4 VFM, VFT, () Min./max. rotation speed with standard transmission 2 speed 4/8 pole DAHLANDER motor Motor Rotation () Voltage Protection Cos power speed (V/phase/ current (kw) (tr/mn) Hz) 400 V (A) CBP DP C48 0,/0,3 30/30 400/3/0,8/0,9 0,/0,62 CBP DP D48 0,/0, 340/60 400/3/0 2,/,02 0,8/0,63 CBP DP E48,0/0,26 390/ /3/0 2,9/, 0,9/0, CBP DP F48,0/0,3 0/ /3/0 4/,8 0,8/0,60 CALAD I rue de Saint Véran I 000 MÂCON LOCHÉ I Tél. 33 (0) Fax 33 (0) I

8 PERFORMANCE HEAT MODULES SIZE CBX CBX BC Temp. incoming ( C/ C) air ( C) Air flow (m 3 /h) /0 - Puis. (kw)/temp. sortie air ( C) 20,8 / 30, 24,9 / 2,9 28,4 / 22,4 3,6 / 9,6 34, /,4 3,8 / 6,4 Débit eau (l/h)/dp eau (kpa) 920 / 4 00 / / / / 36 Puis. (kw)/temp. sortie air ( C) 8,9 / 3,8 22, / 3,4 2,9 / 28,2 28,8 / 2,6 3,4 / 23,4 32, / 22,6 Débit eau (l/h)/dp eau (kpa) 840 / 2 00 / 0 / / / / 3 Puis. (kw)/temp. sortie air ( C),8 / 44,6 8,8 / 40, 2, / 43,8 23,9 / 3, 26, / 33,6 2, / 32,9 Débit eau (l/h)/dp eau (kpa) 00 / / 2 90 / 060 / 8 60 / / 22 Puis. (kw)/temp. sortie air ( C) 3,9 / 49,3 6, / 4, 9 / 43, 2, / 4 23 / 39,3 23,9 / 38, Débit eau (l/h)/dp eau (kpa) 620 / 40 / 0 0 / / 020 / 060 / 8 80/60 - CBX BF Temp. incoming air ( C/ C) ( C-%HR) /2 6/ Evap. temp. ( C) Puis. (kw)/temp. sortie air ( C) 8,4 / 2,3 22 / 2,2 2, / 8, 2,9 /,6 30, / 3,6 3, / 2,8 Débit eau (l/h)/dp eau (kpa) 80 / 2 90 / 6 0 / / / / 30 Puis. (kw)/temp. sortie air ( C) 6,6 / 30,4 9,8 / 26,6 22,6 / 23, 2, / 2,4 2,4 / 9,6 28, / 8,8 Débit eau (l/h)/dp eau (kpa) 30 / 0 80 / / 0 / / / 2 Puis. (kw)/temp. sortie air ( C) 3,4 / 38,9 6 / 3,6 8,2 / 33, 20,2 / 3, 22, / 29, 22,9 / 28,9 Débit eau (l/h)/dp eau (kpa) 90 / 0 / 9 80 / / 4 90 / 6 00 / Puis. (kw)/temp. sortie air ( C),6 / 43,4 3,8 / 40,, / 38,2, / 36, 9 / 3 9, / 34, Débit eau (l/h)/dp eau (kpa) 0 / 0 / 00 / 9 0 / 840 / 2 80 / 3 Air flow (m 3 /h) Puis. (kw)/t. sort. air ( C-%HR),3 / 6,4-8 8, /,2-8,8 / 8-6 9,4 / 8,6-9,8 / 9,-4 0,2 / 9,6-4 0,4 / 9,8-4 Débit eau (l/h)/dp eau (kpa) 260 / / 9 0 / / / 26 0 / / 29 Puis. (kw)/t. sort. air ( C-%HR),6 /,3-6,2 / , / 6,6-8, / -8,4 /,-80, /,-80,8 / 8-9 Débit eau (l/h)/dp eau (kpa) 960 / / 2 40 / 3 20 / 20 / 6 30 / 330 / Puis. (kw)/t. sort. air ( C-%HR) 4,3 / -82 4,6 /,6-82 4,9 / 6,-8, / 6,-80,3 / 6,9-80,4 /,2-9, /,3-9 Débit eau (l/h)/dp eau (kpa) 30 / 6 90 / 840 / / 8 90 / / / 9 Puis. (kw)/t. sort. air ( C-%HR), /,9-8 8,6 / 6,8-9,3 /,-6 9,9 / 8,2-0,4 / 8,-4 0,9 / 9,2-4, / 9,-4 Débit eau (l/h)/dp eau (kpa) 320 / 40 / / / / / / 32 Puis. (kw)/t. sort. air ( C-%HR) 6,0 / 4,8-6, /,-82,2 / 6,-8, / 6,6-8 8,0 / -80 8,4 /,4-80 8, /,6-9 Débit eau (l/h)/dp eau (kpa) 030 / 40 / / 30 / 380 / / / 20 Puis. (kw)/t. sort. air ( C-%HR) 4,8 / 4,3-,2 / 4,9-82,6 /,-8,9 /,9-80 6,2 / 6,3-80 6,4 / 6,6-9 6,4 / 6,8-9 Débit eau (l/h)/dp eau (kpa) 820 / 900 / / 0 00 / 060 / 090 / 2 00 / 2 CBX DX Temp. of incoming air ( C-%HR) Air flow (m 3 /h) Puis. (kw) 8, 8,9 9, 9,8 0, 0,2 T. sort. air ( C-%HR) ,9-80,8-9 8,-8 9,2- Puis. (kw) 6,6,,6,9 8, 8,2 T. sort. air ( C-%HR) 3,-86 4,-8,4-84 6,- 6,-,2-82 Puis. (kw),4,8 6,0 6,2 6,3 6,3 T. sort. air ( C-%HR) 3, ,-84,3-,9-6,3-82 Puis. (kw) 9,2 0, 0,8,3, 2,0 T. sort. air ( C-%HR) 3,4-4,-8,-80 6,6-9,4-8 8,- Puis. (kw),6 8,3 8,9 9,3 9, 0,0 T. sort. air ( C-%HR) 2,3-8 3,4-86 4,2-8 4,9-84,6-6,- Puis. (kw) 6,4 6,9,4,,9 8, T. sort. air ( C-%HR),8-86 2,-8 3,-84 4,2-4,8-,3-82 CBX BE Total Total power in Voltage Weight ELECTROPACK power kw kw per stage V CBX-BE kg type CBX BE 02,2,2 400 TRI 38 2 TA ou DF* CBX BE 0 0, 0, 400 TRI 40 2 TA ou DF* CBX BE,, 400 TRI 42 2 TA ou DF* CBX BE TRI 44 2 TA ou DF* *DF if the exhaust fan is controlled by the ELECTROPACK Recap: simplified calculation rule to determine the power of the electrical coil. Flow rate (m 3 /h) x s T ( C) = Power (kw) 3000 P0

9 COMBIBOX SELECTION CURVES SIZE 6 CBP 6 DP tr/mn 82 Static pressure CBP (Pa) C D E F G Additional modules CBX 6 Losses of loads options (Pa) Acoustic module Charcoal module ELECTRICAL COMBIBOX P02 -speed 4-pole motor Motor Rotation Voltage Protection Cos Speed controller pwr. speed () current Supply. 230 V single phase Supply. 400 V three phase (kw) (rpm) (V/phase/Hz) 400V (A) output 230 V three-phase output 400 V three-phase CBP 6 DP C4 0, 860/ /3/0,60 0,6 VFM 0, VFT 0, CBP 6 DP D4 0, 00/ /3/0,90 0,4 VFM 0, VFT 0, CBP 6 DP E4,0 0/ /3/0 2,2 0,8 VFM, VFT, CBP 6 DP F4,0 330/ /3/0 3, 0,4 VFM, VFT, CBP 6 DP G4 2,20 40/ /3/0,00 0,6 VFM 2,2 VFT 2,2 () Min./max. rotation speed with standard transmission 2 speed 4/8 pole DAHLANDER motor Motor Rotation () Voltage Protection Cos power speed (V/phase/ current (kw) (tr/mn) Hz) 400 V (A) CBP 6 DP C48 0,/0,3 860/0 400/3/0,8/0,9 0,/0,62 CBP 6 DP D48 0,/0, 030/ /3/0 2,/,02 0,8/0,63 CBP 6 DP E48,0/0,26 60/20 400/3/0 2,9/, 0,9/0, CBP 6 DP F48,0/0,3 300/0 400/3/0 4/,8 0,8/0,60 CBP 6 DP G48 2,20/0, 400/0 400/3/0,2/2,6 0,8/0,8 CALAD I rue de Saint Véran I 000 MÂCON LOCHÉ I Tél. 33 (0) Fax 33 (0) I

10 HEAT MODULES SIZE PERFORMANCE CBX6 CBX 6 BC Temp. incoming ( C/ C) air ( C) Débit air (m 3 /h) /0 - Puis. (kw)/temp. sortie air ( C) 2,8 / 33, 33, / 29 38, / 2, 42,9 / 22,6 4,0 / 20,3 0, / 8,4 4,2 / 6, Débit eau (l/h)/dp eau (kpa) 230 / / 3 0 / 900 / / / / 3 Puis. (kw)/temp. sortie air ( C) 2,4 / 38,8 30, / 34,4 3, / 3, 39, / 28,4 42,8 / 26,2 46,2 /24,3 49,3 /22, Débit eau (l/h)/dp eau (kpa) 20 / 8 30 / 60 / 4 40 / 900 / / / 26 Puis. (kw)/temp. sortie air ( C) 2, / 4,2 2,4 / 43,3 29, / 40,3 32, / 38,0 3, / 36,0 38,3 / 34,4 40,9 / 33 Débit eau (l/h)/dp eau (kpa) 940 / 6 30 / / / 3 0 / 00 / 80 / 9 Puis. (kw)/temp. sortie air ( C) 8, /, 22,4 / 48, 2, / 4,4 28, / 43,2 3,3 /4,4 33,8 / 39,9 36 / 38,6 Débit eau (l/h)/dp eau (kpa) 0 / 990 / 40 / 8 20 / /2 00 / / 80/60 - CBX 6 BF temp. incoming air ( C/ C) ( C-%HR) /2 6/ Evap. temp. ( C) Puis. (kw)/temp. sortie air ( C) 24,6 / 28,2 29,6 / / 20,8 3,9 / 8,3 4, / 6,2 44,8 / 4,4 4,8 / 2,9 Débit eau (l/h)/dp eau (kpa) 090 / 8 30 / 00 / / 0 / / / 2 Puis. (kw)/temp. sortie air ( C) 22,2 / 33, 26, / 29,2 30,6 / 26,2 34, / 23,9 3,3 / 2,9 40,3 / 20,3 43 /8,9 Débit eau (l/h)/dp eau (kpa) 980 / 80 / 9 30 / 2 0 / 4 0 / 6 80 / / 2 Puis. (kw)/temp. sortie air ( C),9 / 4,2 2, / 3,8 24, / 3,2 2, / 33,2 30 / 3, 32,4 /30,2 34, /29 Débit eau (l/h)/dp eau (kpa) 90 / 90 / / 8 20 / / 430 / 3 30 / 4 Puis. (kw)/temp. sortie air ( C), / 4, 8,6 / 42,4 2,3 / 40, 23, / 38,3 2,9 / 36,8 2,9 /3,6 29, /34, Débit eau (l/h)/dp eau (kpa) 680 / / 940 / 6 00 / 40 / / 0 30 / Débit air (m 3 /h) Puis. (kw)/t. sort. air ( C-%HR) 0, /,9-9 2,4 /,- 3, / 8,0-6 4,8 / 8,8-, / 9,-4 6,2 / 9,9-4 Débit eau (l/h)/dp eau (kpa) 0 / / / / / 2 20 / 28 Puis. (kw)/t. sort. air ( C-%HR) 8,2 /,0-84 9,4 /,9-82 0,4 / 6,6-8, /,2-80, /,-80 2, / 8,-9 Débit eau (l/h)/dp eau (kpa) 400 / 8 0 / 0 / 3 90 / 200 / / Puis. (kw)/t. sort. air ( C-%HR) 6,4 / 4,-,2 /,3-82,9 / 6-8 8,3 / 6,-80 8,6 / -80 8,8 /,3-9 Débit eau (l/h)/dp eau (kpa) 090 / / 30 / / / 9 0 / 0 Puis. (kw)/t. sort. air ( C-%HR),4 /,2-9 3,3 / 6,4-4,8 /,4-6 6,0 / 8,2-, / 8,9-4, / 9,4-4 Débit eau (l/h)/dp eau (kpa) 960 / 220 / / / / / 33 Puis. (kw)/t. sort. air ( C-%HR) 8,9 / 4,3-84 0,3 /,2-82, / 6-8 2,4 / 6,6-8 3, /,2-80 3,6 /,-9 Débit eau (l/h)/dp eau (kpa) 30 / 0 0 / / 220 / / / 2 Puis. (kw)/t. sort. air ( C-%HR),2 / 3,8-8,2 / 4,-82 9,0 /,4-8 9,6 /,9-80 0, / 6,4-80 0,3 / 6,-9 Débit eau (l/h)/dp eau (kpa) 220 / 400 / 9 30 / 0 0 / 20 / 2 0 / 3 CBX 6 DX Temp. of incoming air ( C-%HR) Débit air (m 3 /h) Puis. (kw) 2,3 4,0,2,9 6,4 6, T. sort. air ( C-%HR) 3,9-,-8 6,8-80,8-9 8,-8 9,- Puis. (kw) 9,9,2 2, 2,8 3,2 3,3 T. sort. air ( C-%HR) 3-8 4,3-8,3-84 6,- 6,8-,-82 Puis. (kw) 8,2 9, 9, 0, 0,3 0,3 T. sort. air ( C-%HR) 2,-86 3,-8 4,6-84,4-6- 6,3-82 Puis. (kw) 3,8,,2 8,3 9, 9,3 T. sort. air ( C-%HR) 2,-84 4,2-82,-80 6,-9,6-8 8,- Puis. (kw),4 3,0 3,0,2,8 6, T. sort. air ( C-%HR),-88 2,9-86 2, ,- 6,- Puis. (kw) 9,6 0,9,8 2, 2,9 3, T. sort. air ( C-%HR),-8 2,4-8 3,4-84 4,2-4,9-,2-82 CBX 6 BE Total Total power in Voltage Weight ELECTROPACK power kw kw per stage V CBX-BE kg type CBX 6 BE 3 3, 3, 400 TRI 4 2 TA ou DF* CBX 6 BE ,2 20,2 400 TRI 49 2 TA ou DF* CBX 6 BE TRI 2 2 TA ou DF* CBX 6 BE 33 33, 20,2 + 3, 400 TRI 42 TA ou DF* *DF if the exhaust fan is controlled by the ELECTROPACK Recap: simplified calculation rule to determine the power of the electrical coil. Flow rate (m 3 /h) x s T ( C) = Power (kw) 3000 P03

11 COMBIBOX SELECTION CURVES SIZE CBP DP tr/mn Static pressure CBP (Pa) D 69 E 6 4 F G 60 8 H Additional modules CBX Losses of loads options (Pa) Acoustic module Charcoal module ELECTRICAL COMBIBOX P04 -speed 4-pole motor Motor Rotation Voltage Protection Cos Speed controller pwr. speed () current Supply. 230 V single phase Supply. 400 V three phase (kw) (rpm) (V/phase/Hz) 400V (A) output 230 V three-phase output 400 V three-phase CBP DP D4 0, 0/ /3/0,90 0,4 VFM 0, VFT 0, CBP DP E4,0 890/ /3/0 2,2 0,8 VFM, VFT, CBP DP F4,0 990/ /3/0 3, 0,4 VFM, VFT, CBP DP G4 2,20 00/ /3/0,00 0,6 VFM 2,2 VFT 2,2 CBP DP H4 3,00 60/ /3/0 6,2 0, - VFT 3 () Min./max. rotation speed with standard transmission 2 speed 4/8 pole DAHLANDER motor Motor Rotation () Voltage Protection Cos power speed (V/phase/ current (kw) (tr/mn) Hz) 400 V (A) CBP DP D48 0,/0, 90/00 400/3/0 2,/,02 0,8/0,63 CBP DP E48,0/0,26 880/60 400/3/0 2,9/, 0,9/0, CBP DP F48,0/0,3 90/ /3/0 4/,8 0,8/0,60 CBP DP G48 2,20/0,0 00/30 400/3/0,2/2,6 0,8/0,8 CBP DP H48 3,00/0, 0/40 400/3/0 6,8/3 0,8/0, CALAD I rue de Saint Véran I 000 MÂCON LOCHÉ I Tél. 33 (0) Fax 33 (0) I

12 HEAT MODULES SIZE PERFORMANCE CBX CBX BC Temp. incoming ( C/ C) air ( C) Débit air (m 3 /h) /0 - Puis. (kw)/temp. sortie air ( C) 23,3 / 46,3 49,3 / 28,2 8,9 / 23, 6, / 20,3 4, /, 8, /, Débit eau (l/h)/dp eau (kpa) 030 / / 0 20 / / / / 2 Puis. (kw)/temp. sortie air ( C) 2,3 / 0,8 44,9 / 33,6 3,6 / 29,4, / 26,2 6,8 /23,6 3,8 / 2,6 Débit eau (l/h)/dp eau (kpa) 90 / / / 2 20 / 300 / / 2 Puis. (kw)/temp. sortie air ( C),8 /,8 3,3 / 42,6 44,4 / 38,8 0,6 / 36,0 6, / 33,8, / 32,0 Débit eau (l/h)/dp eau (kpa) 90 / 2 0 / 6 90 / / 2490 / 3 20 / Puis. (kw)/temp. sortie air ( C), /, 32,9 / 4,4 39,2 / 43,9 44,6 / 4,3 49,4 / 39,3 3,8 / 3, Débit eau (l/h)/dp eau (kpa) 00 / / 40 / 980 / / 2380 / 2 80/60 - CBX BF Temp. incoming air ( C/ C) ( C-%HR) /2 6/ Evap. temp. ( C) Puis. (kw)/temp. sortie air ( C) 20, / 39,4 43,6 / 23,2 2,0 / 9,2 9,2 / 6,, / 3,8, /,9 Débit eau (l/h)/dp eau (kpa) 90 / / / / 2900 / / 20 Puis. (kw)/temp. sortie air ( C) 8, / 43,6 39,2 / 28,4 46, / 24, 3,2 / 2,9 9,0 / 9,,2 /,9 Débit eau (l/h)/dp eau (kpa) 820 / 2 30 / 2060 / / 2 20 / 20 / Puis. (kw)/temp. sortie air ( C), / 0,3 3,6 / 3, 3,6 / 33,9 42, /3, 4,3 /29,6, / 28,0 Débit eau (l/h)/dp eau (kpa) 60 / / 660 / 890 / / / Puis. (kw)/temp. sortie air ( C) 3, / 3, 2,2 / 4,8 32,3 / 38,9 36,8 / 36, 40, / 3,0 44,2 / 33,6 Débit eau (l/h)/dp eau (kpa) 80 / 200 / / 620 / / 8 90 / 9 Débit air (m 3 /h) Puis. (kw)/t. sort. air ( C-%HR) 9,2 / 2,-84 22,4 / 3,8-2,2 / 4,-8 2, /, ,9 / 6,-9 3,9 / 6,-8 33,6 /,2-8 Débit eau (l/h)/dp eau (kpa) 3300 / / / / / / / 36 Puis. (kw)/t. sort. air ( C-%HR) 4,9 / 2,-88,3 / 3,3-86 9,4 / 4-8 2,2 / 4, ,8 /,-84 24,2 /,6-2, / 6-82 Débit eau (l/h)/dp eau (kpa) 260 / / 3320 / / / 8 40 / / 22 Puis. (kw)/t. sort. air ( C-%HR) 2,0 / 2,3-8 3,8 / 3-86,3 / 3,-8 6,6 / 4,2-84, / 4,- 8, /,- 9, /,4-82 Débit eau (l/h)/dp eau (kpa) 200 / / / / / / / 4 Puis. (kw)/t. sort. air ( C-%HR) 20,4 /,9-8 23,8 / 3-26,8 / 3, , / 4,-80 32,0 /,4-9 34,2 / , / 6,6-8 Débit eau (l/h)/dp eau (kpa) 3490 / 400 / / / / / 3 90 / 4 Puis. (kw)/t. sort. air ( C-%HR) 6, /,6-88 8, / 2,-8 2,0 / 3, , / 3,9-8 24,9 / 4, ,6 / 4,9-28, /,3- Débit eau (l/h)/dp eau (kpa) 260 / / / / / / / 26 Puis. (kw)/t. sort. air ( C-%HR) 3,2 /,4-8,2 / 2,2-86,0 / 2,9-8 8,6 / 3,-84 9,9 / 4-2, / 4,4-22, / 4,8-82 Débit eau (l/h)/dp eau (kpa) 2260 / 20 / / 380 / / 4 30 / / CBX DX Temp. of incoming air ( C-%HR) Débit air (m 3 /h) Puis. (kw) 8,2 20, 22,2 23, 24,4 2,0 T. sort. air ( C-%HR) 3,-84 4, ,9-8 8,6-8 Puis. (kw) 4, 6,,9 9,0 9, 20,2 T. sort. air ( C-%HR) 2,6-8 3,-86 4,-8,4-84 6,- 6,- Puis. (kw) 2,2 3, 4,,2,6,9 T. sort. air ( C-%HR) 2,2-8 3, ,-84,3-,9- Puis. (kw) 20,3 22,9 2,0 26, 2,9 28,8 T. sort. air ( C-%HR) 2,0-8 3,- 4,8-8,8-80 6,8-9,6-8 Puis. (kw) 6,8 9,0 20,8 22,2 23,3,6- T. sort. air ( C-%HR),-88 2,4-8 3,4-8 4,2-84,0-84,6- Puis. (kw) 4,2 6,0,4 8,4 9,2 9, T. sort. air ( C-%HR) 0,-8,8-86 2,8-8 3,-84 4,2-4,8- CBX BE Total Total power in Voltage Weight ELECTROPACK power kw kw per stage V CBX-BE kg type CBX BE 6, 6, 400 TRI 4 2 TA ou DF* CBX BE 24 24, 24, 400 TRI 2 TA ou DF* CBX BE , + 6, 400 TRI TA ou DF* CBX BE 49 49, 24, +24, 400 TRI TA ou DF* *DF if the exhaust fan is controlled by the ELECTROPACK Recap: simplified calculation rule to determine the power of the electrical coil. Flow rate (m 3 /h) x s T ( C) = Power (kw) 3000 P0

13 COMBIBOX SELECTION CURVES SIZE 8 CBP 8 DP Static pressure CBP (Pa) tr/mn F G H I Additional modules CBX 8 Losses of loads options (Pa) Acoustic module Charcoal module ELECTRICAL COMBIBOX -speed 4-pole motor Motor Rotation Voltage Protection Cos Speed controller pwr. speed () current Supply. 230 V single phase Supply. 400 V three phase (kw) (rpm) (V/phase/Hz) 400V (A) output 230 V three-phase output 400 V three-phase CBP 8 DP F4,0 0/ /3/0 3, 0,4 VFM, VFT, CBP 8 DP G4 2,20 90/ /3/0,00 0,6 VFM 2,2 VFT 2,2 CBP 8 DP H4 3,00 900/ /3/0 6,2 0, - VFT 3 CBP 8 DP I4 4,00 90/ /3/0 8,90 0,8 - VFT 4 () Min./max. rotation speed with standard transmission 2 speed 4/8 pole DAHLANDER motor Motor Rotation () Voltage Protection Cos power speed (V/phase/ current (kw) (tr/mn) Hz) 400 V (A) CBP 8 DP F48,0/0,3 0/ /3/0 4/,8 0,8/0,60 CBP 8 DP G48 2,20/0,0 90/ /3/0,2/2,6 0,8/0,8 CBP 8 DP H48 3,00/0, 900/40 400/3/0 6,8/3 0,8/0, CBP 8 DP I48 4,00/,00 960/ /3/0 8,6/3, 0,/0,60 P06 CALAD I rue de Saint Véran I 000 MÂCON LOCHÉ I Tél. 33 (0) Fax 33 (0) I

14 HEAT MODULES SIZE 8 PERFORMANCE CBX8 CBX 8 BC Temp. incoming ( C/ C) air ( C) Débit air (m 3 /h) /0 - Puis. (kw)/temp. sortie air ( C) 80,8 / 2, 90,4 / 24,6 99, / 22,2 0 / 20,2 / 8, 22 /,0 28 /, Débit eau (l/h)/dp eau (kpa) 380 / / / 2 40 / / / 690 / 9 Puis. (kw)/temp. sortie air ( C) 3, / 32,9 82,3 / 30,2 90,2 / 28,0 98 / 26, 04 / 24,4 / 23,0 / 2,8 Débit eau (l/h)/dp eau (kpa) 3260 / 30 / / / / / 0 / 6 Puis. (kw)/temp. sortie air ( C) 60,9 / 4,9 68, / 39, 4, / 3, 8 / 3,8 86 /34,4 9 / 33,2 96 / 32,2 Débit eau (l/h)/dp eau (kpa) 200 / 3020 / / 380 / / / 420 / 2 Puis. (kw)/temp. sortie air ( C) 3,8 / 46, 60, / 44,,8 / 42, / 4,2 6 / 39,9 8 / 38, 8 / 3,9 Débit eau (l/h)/dp eau (kpa) 2380 / / 2920 / 6 30 / 330 / 8 30 / / 9 80/60 - CBX 8 BF Temp. incoming air ( C/ C) ( C-%HR) /2 6/ Evap. temp. ( C) Puis. (kw)/temp. sortie air ( C),2 / 22, 9, / 9,9 8,3 /,8 94 / 6,0 0 / 4, 0 / 3,2 3 / 2,0 Débit eau (l/h)/dp eau (kpa) 30 / 320 / / 0 40 / 4460 / / / 6 Puis. (kw)/temp. sortie air ( C), / 2,,6 / 2,4 8, / 23,4 8 / 2, 9 / 20,3 96 / 9, 0 / 8,0 Débit eau (l/h)/dp eau (kpa) 20 / / 3460 / / / 4240 / / 3 Puis. (kw)/temp. sortie air ( C), / 36,, / 34,4 63,0 / 32, 68 /3,3 3 / 30, / 29,0 8 / 28,2 Débit eau (l/h)/dp eau (kpa) 220 / / 280 / / / 3400 / / 9 Puis. (kw)/temp. sortie air ( C) 44,3 / 4,2 49,4 / 39,3 4, / 3,8 8 / 36, 62 / 3,4 66 / 34, 0 / 33,8 Débit eau (l/h)/dp eau (kpa) 960 / / / / 20 / /6 300 / Débit air (m 3 /h) Puis. (kw)/t. sort. air ( C-%HR) 28,9 / 2,-84 3, / 4,-82 40,4 /,2-8 4,0 / 6,-9 48,9 / 6,8-8,6 /,4-8 Débit eau (l/h)/dp eau (kpa) 490 / / / 00 / 2 0 / / 2 Puis. (kw)/t. sort. air ( C-%HR) 22,3 / 2,-88 2,0 / 3,-88 30,9 / 4,4-8 34,2 /,-84 3,0 /,- 38,9 / 6,-82 Débit eau (l/h)/dp eau (kpa) 30 / / / 860 / / 660 / 6 Puis. (kw)/t. sort. air ( C-%HR),9 / 2,3-8 2,4 / 3,3-8 24,2 / , / 4,- 28,4 /,2-29,6 /,6-82 Débit eau (l/h)/dp eau (kpa) 300 / / 6 40 / 440 / / / 0 Puis. (kw)/t. sort. air ( C-%HR) 30,6 /,9-8 3,3 / 3,3-43, / 4,4-8 48, /,4-80 2,4 / 6,2-8, / 6,-8 Débit eau (l/h)/dp eau (kpa) 230 / 6390 / 380 / / / / 3 Puis. (kw)/t. sort. air ( C-%HR) 24, /, ,3 / 2, ,6 / 3,-8 3,4 / 4, , / - 43,0 /,- Débit eau (l/h)/dp eau (kpa) 430 / 00 / 0 60 / 3 0 / 6960 / 8 30 / 20 Puis. (kw)/t. sort. air ( C-%HR) 9, /,4-8 23, / 2,-86 2,0 / 3, ,8 / , / 4,- 33, / 4,9-82 Débit eau (l/h)/dp eau (kpa) 3380 / 4060 / 4630 / 9 00 / 0 00 / 2 0 / 3 CBX 8 DX Temp. of incoming air ( C-%HR) Débit air (m 3 /h) Puis. (kw) 28,0 32,6 3,8 38,0 39,3 39,6 T. sort. air ( C-%HR) 3,-84 32,6 / -82 6,4-80,6-9 8,-8 8,9- Puis. (kw) 22,6 26,3 28,9 30,8 3,9 32,2 T. sort. air ( C-%HR) 2,3-88 3,8-86 4,9-84,8-6,6-6,9-82 Puis. (kw) 8, 2, 23,4 24, 2, 2, T. sort. air ( C-%HR),9-8 3,2-8 4,3-84,-,8-,8- Puis. (kw) 3,0 36,4 40,4 43,3 4,2 4, T. sort. air ( C-%HR),-8 3,6-82,2-80 6,4-9,-8,9-8 Puis. (kw) 2, 30,2 33,6 36, 3,8 38,4 T. sort. air ( C-%HR) 0,8-89 2,4-86 3,-8 4,-84,6-,9- Puis. (kw) 2,9 2, 28, 29,9 3, 3,4 T. sort. air ( C-%HR) 0,4-88, ,- -82 CBX 8 BE Total Total power in Voltage Weight ELECTROPACK power kw kw per stage V CBX-BE kg type CBX 8 BE TRI TA ou DF* CBX 8 BE TRI TA ou DF* CBX 8 BE TRI TA ou DF* CBX 8 BE TRI 90 - *DF if the exhaust fan is controlled by the ELECTROPACK Recap: simplified calculation rule to determine the power of the electrical coil. Flow rate (m 3 /h) x s T ( C) = Power (kw) 3000 P0

15 COMBIBOX SELECTION CURVES SIZE 9 CBP 9 DP tr/mn Static pressure CBP (Pa) G H I J Additional modules CBX 9 Losses of loads options (Pa) Acoustic module Charcoal module ELECTRICAL COMBIBOX -speed 4-pole motor Motor Rotation Voltage Protection Cos Speed controller pwr. speed () current Supply. 230 V single phase Supply. 400 V three phase (kw) (rpm) (V/phase/Hz) 400V (A) output 230 V three-phase output 400 V three-phase CBP 9 DP G4 2,20 0/ /3/0,00 0,6 VFM 2,2 VFT 2,2 CBP 9 DP H4 3,00 0/ /3/0 6,2 0, - VFT 3 CBP 9 DP I4 4,00 0/ /3/0 8,90 0,8 - VFT 4 CBP 9 DP J4,0 80/ /3/0,30 0,82 - VFT () Min./max. rotation speed with standard transmission 2 speed 4/8 pole DAHLANDER motor Motor Rotation () Voltage Protection Cos power speed (V/phase/ current (kw) (tr/mn) Hz) 400 V (A) CBP 9 DP G48 2,20/0,0 60/0 400/3/0,2/2,6 0,8/0,8 CBP 9 DP H48 3,00/0, 0/80 400/3/0 6,8/3 0,8/0, CBP 9 DP I48 4,00/,00 80/90 400/3/0 8,6/3, 0,/0,60 CBP 9 DP 48,0/,3 90/ /3/0,4/4, 0,84/0,60 P08 CALAD I rue de Saint Véran I 000 MÂCON LOCHÉ I Tél. 33 (0) Fax 33 (0) I

16 HEAT MODULES SIZE 9 PERFORMANCE CBX9 CBX 9 BC Temp. incoming ( C/ C) air ( C) Débit air (m 3 /h) /0 - Puis. (kw)/temp. sortie air ( C) 0 / 30,9 26 / 26,3 44 / 22,8 60 / 20,0 4 /,8 88 /,9 Débit eau (l/h)/dp eau (kpa) 40 / 3 0 / / / 2 40 / / 36 Puis. (kw)/temp. sortie air ( C) 9, / 36,2 4 / 3,8 3 / 28, 46 / 2,9 9 / 23,8 / 22,0 Débit eau (l/h)/dp eau (kpa) 4240 / 080 / 80 / 9 60 / / 2 90 / 3 Puis. (kw)/temp. sortie air ( C) 9,4 / 44,9 9, / 4,0 09 / 38, 2 / 3,8 32 / 33,9 42 / 32, Débit eau (l/h)/dp eau (kpa) 320 / / 4820 / / 840 / / 22 Puis. (kw)/temp. sortie air ( C) 0,3 / 49,6 84,0 / 46,0 96 / 43,3 0 / 4,2 6 / 39, 2 / 38,2 Débit eau (l/h)/dp eau (kpa) 320 / 330 / / 430 / 3 60 / 6 0 / 8 80/60 - CBX 9 BF Temp. incoming air ( C/ C) ( C-%HR) /2 6/ Evap. temp. ( C) Puis. (kw)/temp. sortie air ( C) 92, / 2,6 / 2, 2 / 8,4 4 /,9 4 / 3,9 66 / 2,3 Débit eau (l/h)/dp eau (kpa) 400 / 4900 / 0 / / 23 6 / / 30 Puis. (kw)/temp. sortie air ( C), / 30, 00 / 26,9 4 / 24,0 2 / 2, 39 / 9,8 49 / 8,3 Débit eau (l/h)/dp eau (kpa) 3690 / / 2 00 / 6 0 / 9 20 / / 2 Puis. (kw)/temp. sortie air ( C) 6, / 39,2 80,6 / 3,8 92 / 33,3 02 / 3,4 / 29,8 20 / 28, Débit eau (l/h)/dp eau (kpa) 2980 / / / 420 / / 300 / Puis. (kw)/temp. sortie air ( C) 8,3 / 43, 69,6 / 40, 9 / 38,4 88 / 36, 96 / 3,2 03 / 34,2 Débit eau (l/h)/dp eau (kpa) 280 / 300 / 30 / / / / 3 Débit air (m 3 /h) Puis. (kw)/t. sort. air ( C-%HR),4 / 4,4-82 6,6 /,-8,2 /,8-80,4 / 6,4-9 69,2 / 6,9-8 2, /,4-8 4, /,6- Débit eau (l/h)/dp eau (kpa) 8 / / / 6 20 / 8 80 / / / 22 Puis. (kw)/t. sort. air ( C-%HR) 39,3 / 3, ,0 / 4,4-8 46,4 / 4, ,4 /,4-84 2, /,8-4, / 6,2-, / 6,3-82 Débit eau (l/h)/dp eau (kpa) 630 / 30 / 9 90 / / 8920 / / /3 Puis. (kw)/t. sort. air ( C-%HR) 30,9 / 3,-8 33,6 / 4,-84 36,0 / 4,-84 38,0 / 4,9-39,8 /,3-4,2 /,6-82 4,9 /,8-82 Débit eau (l/h)/dp eau (kpa) 300 / 60 / 6 60 / 6 0 / 680 / 00 / 8 80 / 8 Puis. (kw)/t. sort. air ( C-%HR) 4, / 3, ,4 / 4,4-8, /,-80 0, /,-9 4,3 / 6,2-9 8,2 / 6,-8 9,9 / 6,9-8 Débit eau (l/h)/dp eau (kpa) 9360 / / 6 20 / / / / / 2 Puis. (kw)/t. sort. air ( C-%HR) 42, / 3,-86 4,0 / 3,-8 0,8 / 4,2-8 4,3 / 4,-84,4 /,- 60,2 /,-, /,- Débit eau (l/h)/dp eau (kpa) 30 / / 0 / 9290 / 3 90 / / 030 / 6 Puis. (kw)/t. sort. air ( C-%HR) 34,4 / 2,8-8 3,6 / 3,3-8 40,4 / 3, ,9 / 4,2-4, / 4,6-4, / -82 4,9 /,-82 Débit eau (l/h)/dp eau (kpa) 890 / 6 40 / 6920 / 8 30 / 9 30 / / / 0 CBX 9 DX Temp. of incoming air ( C-%HR) Débit air (m 3 /h) Puis. (kw) 48,,9 4, 6,4,8 8,6 T. sort. air ( C-%HR),0-82 6,0-80 6,9-9,6-9 8,3-8 8,9- Puis. (kw) 39,2 4,9 44, 4, 46,9 4, T. sort. air ( C-%HR) 3,9-86 4,6-8,3-84,9-6,4-6,9-82 Puis. (kw) 32,0 34,0 3,4 36,4 3, 3,3 T. sort. air ( C-%HR) 3,3-8 4,0-84 4,6-84,2-,6-6,-82 Puis. (kw) 4,2 8,4,,3 66,3 6, T. sort. air ( C-%HR) 3,-82 4,8-8,-80 6,-9,3-8,9- Puis. (kw) 4,0 48,,3 3,6,4 6,8 T. sort. air ( C-%HR) 2,-86 3,4-8 4,-84 4,8-84,4-,9- Puis. (kw) 3,9 40,6 42, 44,4 4,6 46, T. sort. air ( C-%HR) 2,0-86 2,-8 3, ,6-,-82 CBX 9 BE Total Total power in Voltage Weight ELECTROPACK power kw kw per stage V CBX-BE kg type CBX 9 BE TRI TA ou DF* CBX 9 BE TRI 9 83 TA ou DF* CBX 9 BE TRI TA ou DF* CBX 9 BE K TRI 3 - *DF if the exhaust fan is controlled by the ELECTROPACK Recap: simplified calculation rule to determine the power of the electrical coil. Flow rate (m 3 /h) x s T ( C) = Power (kw) 3000 P09

17 CBI-CBZ-CBP MOUNTING OPTIONS RAIN HOOD ref. TCB For exterior fitting, metal sheet RAL 03 prelacquered ADDITIONAL PANEL ref. PA-- To produce configurations HHV, HVH, BHD and BDH. Required on the air supply side if additional module assembled. For circular fitting on damper for 2 or 3 channel modules. RAIN COWL ref. AGC With safety and bird protection mesh Galvanized steel sheet. G4 AND F FILTER. G4, ref. -F Ref. G4 93% gravimetric. Ref. -F High efficiency 8% opacimetric. FLEXIBLE MO SLEEVES ref. MTS MO Fire classification: M0. Diameter: 20 to mm. SUPPORT FEET ref. PCB (set of 4 feet) Are used when necessary to replace the support brackets supplied with COMBIBOX modules. OPTIONS ELECTRICAL CBI-CBP DIFFERENTIAL PRESSURE SWITCH ref. DEP Ventilation fault detection. fouling detection. PADLOCKABLE SWITCH ref. IPC Placed on the COMBIBOX, meets safety regulations. ELECTRONIC SPEED CONTROLLER ref. REG Manual adjustment of fan speed by integrated or remote potentiometer (230V single-phase only). SPEED CONTROLLER ref. VFM/VFT Regulates fan speed by varying the power supply frequency. ref. VFM: power supply 230 V single phase / output 230 V three-phase. 2-SPEED CONTROL BOX ref. CDA Function: controls and protects two-speed motors. ref. CDA: DAHLANDER coupling. DAMPER MOTORISATION Servomotor mounted. On/Off, modulating 0-0V, with or without return spring, with or without auxiliary contacts. LOBBY SELF-REGULATING CONSTANT PRESSURE UNIT Adapts the fan rotation speed instantaneously to the requirements of the installation. Energy consumption from 30 to 60% and a reduction of sound levels radiated by the system. AQUAPACK - ELECTROPACK CUPBOARD REGULATION PLUG & PLAY Management and control of power plants COMBIBOX CONCEPT. water heating mode (AQUAPACK ) or electrical (ELECTRO- PACK ). P0 CALAD I rue de Saint Véran I 000 MÂCON LOCHÉ I Tél. 33 (0) Fax 33 (0) I

Des solutions dans les règles de l air. CBP Range COMBIBOX CONCEPT. Ventilation modules Thermic modules Air flow from 800 to m 3 /h

Des solutions dans les règles de l air. CBP Range COMBIBOX CONCEPT. Ventilation modules Thermic modules Air flow from 800 to m 3 /h Des solutions dans les règles de l air CBP Range COMBIBOX CONCEPT Ventilation modules Thermic modules Air flow from 800 to 1 000 m 3 /h VENTILATION MODULES DESCRIPTION CBP COMBIBOX CONCEPT The perfect

More information

Heat recovery units type GTDHR

Heat recovery units type GTDHR GTDHR Double flux - 4 m3/h AC 23V type GTDHR Double flux heat recovery unit high efficiency 9%. The range consists of 5 sizes and 6 types for air flow from up to 4 m³/h. Application Ventilation and heat

More information

HEXAMOTION RANGE HEAT RECOVERY

HEXAMOTION RANGE HEAT RECOVERY HEAT RECOVERY HEXAMOTION RANGE Selfregulating and high efficiency (>8%) Heat Recovery Ventilation compact unit with high performance. Econological solution. Airflow from 1 to 8 m3/h CALADAIR I 1 rue de

More information

CYCLONE F 400 smoke extraction casing

CYCLONE F 400 smoke extraction casing Fire protection CYCLONE F smoke extraction casing Presentation of the CYCLONE F range (12) WHY CHOOSE A CYCLONE F? In order to fulfil the requirements of the CE markings (EN 1211-3 and the French governmental

More information

V.I.R.T.U.O. Ventilation boxes. Comfort ventilation boxes

V.I.R.T.U.O. Ventilation boxes. Comfort ventilation boxes Comfort ventilation Very wide flow rate range : 0.11 to 9.72 m 3 /s Standard version with lacquered finish casing APPLICATION ventilation are designed for the ventilation of tertiary or industrial buildings,

More information

Ventilation and controls for professional kitchens. Controls

Ventilation and controls for professional kitchens. Controls Ventilation and controls for professional kitchens Selection guide Choose your kitchen ventilation system Ventilation with built-in odour treatment Olfacarb II Odour treatment with activated carbon, static

More information

V.I.R.T.U.O. Ventilation boxes. Comfort ventilation boxes. Use. Range. Design

V.I.R.T.U.O. Ventilation boxes. Comfort ventilation boxes. Use. Range. Design Comfort ventilation Very wide flow rate range: 0.11 to 9.72 m 3 /s Standard version with lacquered finish casing Use ventilation are designed for the ventilation of tertiary or industrial buildings, for

More information

Engineering Data Manual. New : available with EC motor. High Static Pressure Ductable Fan Coil Unit. Models 07 to to 4650 m 3 /h

Engineering Data Manual. New : available with EC motor. High Static Pressure Ductable Fan Coil Unit. Models 07 to to 4650 m 3 /h Engineering Data Manual New : available with EC motor VH High Static Pressure Ductable Fan Coil Unit Models 07 to 27 800 to 4650 m 3 /h General Characteristics Presentation On model VH 07, coils have 4

More information

BACKWARD CURVE CENTRIFUGAL FANS KABB / KABT Series

BACKWARD CURVE CENTRIFUGAL FANS KABB / KABT Series Cabinet fans manufactured from galvanised steel sheet with double thickness side panels lined with 17 mm thickness of fireproof fibreglass acoustic insulation (M0). Circular duct connection flange on the

More information

CONFIGURABLE HIGH-EFFICIENCY HEAT RECOVERY UNITS CADB/T-HE PRO-REG Series

CONFIGURABLE HIGH-EFFICIENCY HEAT RECOVERY UNITS CADB/T-HE PRO-REG Series False-ceiling models CADB/T-HE 4 to 33 Heat Recovery Compact heat recovery unit with high-efficiency (up to 93%) counter-flow heat exchanger, EUROVENT certified. The casing is made from plasticised galvanised

More information

DIRECT-AIR ILB / ILT Series Rectangular duct fans

DIRECT-AIR ILB / ILT Series Rectangular duct fans IN-LINE DUCT FAN Series Rectangular duct fans Range of in-line rectangular duct fan manufactured from galvanised steel sheet and provided with an inspection cover that can be removed to access the motor/impeller

More information

UTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management

UTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management Ductable units NEW Eco-Design Filter Air handling unit with high available static pressure V3000 control Fresh air management The range of air handling units is designed for suspended ceiling heating and

More information

CHVB / CHVT Series. Cabinet fans designed for smoke extraction in fire condition F BACKWARD CURVED CENTRIFUGAL FANS CHVB / CHVT

CHVB / CHVT Series. Cabinet fans designed for smoke extraction in fire condition F BACKWARD CURVED CENTRIFUGAL FANS CHVB / CHVT BACKWARD CURVED CENTRIFUGAL FANS Series The CHVB-CHVT range is suitable for many general ventilation applications where high system resistances are present; i.e. systems with filters, dampers etc. Range

More information

1 AIR HANDLING UNIT TYPE AIR ACCESS 75

1 AIR HANDLING UNIT TYPE AIR ACCESS 75 SUPPLY 1 AIR HANDLING UNIT TYPE AIR ACCESS 75 Location : EXTERNAL Position : SIDE BY SIDE SLIDING PANELS for COMPLETE ACCESSIBILITY MULTI SERVICE BULKHEAD for HYDRAULIC AND ELECTRICAL CONNECTIONS Self-supporting

More information

ACOUSTIC CABINET FANS CVB / CVT Series

ACOUSTIC CABINET FANS CVB / CVT Series Cabinet fans manufactured from heavy gauge galvanised steel sheet and internally lined with melamine foam flame retardant acoustic insulation (M1). All models incorporate double inlet single phase direct-drive

More information

OPERATING AND COMMISSIONING MANUAL

OPERATING AND COMMISSIONING MANUAL OPERATING AND COMMISSIONING MANUAL 2015/03 1 In compliance with the current norms, the machine should be installed only by a technical person qualified for this type of work. During installation, ensure

More information

ARROW INDUSTRIAL PRODUCTS

ARROW INDUSTRIAL PRODUCTS IP-2R ARROW INDUSTRIAL PRODUCTS For Applications in Industrial, Power Plant & Commercial Projects ARROW UNITED INDUSTRIES ARROW UNITED INDUSTRIES has specialized in the manufacturing of air control products

More information

VIRTUO. Comfort ventilation boxes Self-supporting casing with lacquered

VIRTUO. Comfort ventilation boxes Self-supporting casing with lacquered Comfort ventilation Self-supporting casing with lacquered finish as standard Air intake or exhaust operation Simplified access to internal components ErP READY Air flow: 500 to 35 000 m 3 /h Use ventilation

More information

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series Range of low profile in-line mixed flow duct fans manufactured in tough reinforced plastic (from 16 to 8 models) or with metal casing steel finished in a tough epoxy-polyester paint coating (from 1 to

More information

MegaBox Product-specific information

MegaBox Product-specific information MegaBox Product-specific information Application Noise-encapsulating centrifugal fans with retractable motor impeller unit and motor located outside the air flow Suitable for rough operating conditions

More information

ACOUSTIC CABINET FANS FOR SUPPLY AIR APPLICATIONS CAIB/T PRO-REG Series

ACOUSTIC CABINET FANS FOR SUPPLY AIR APPLICATIONS CAIB/T PRO-REG Series ACOUSTIC CABINET FANS FOR SULY AIR ALICATIONS CAIB/T RO-REG Series Introduction of fresh air to commercial offices and industrial kitchens. Acoustic cabinet fan in galvanised sheet steel with reinforced

More information

Silent centrifugal air heater hot water supply

Silent centrifugal air heater hot water supply Large range : 5 to 120 Flows : 900 to 14000 m 3 /h Numerous accessories Design integrating perfectly in public buildings USE Operation in zones ES and S Extra silent and silent Forced air heating for premises

More information

Series VENTS KSK. Centrifugal kitchen fan in sound-insulated casing with air flow up to 8138 m 3 /h

Series VENTS KSK. Centrifugal kitchen fan in sound-insulated casing with air flow up to 8138 m 3 /h SOUND-INSULATED KITCHEN FAN Series device. The impeller is mounted on the motor shaft and is balanced statically and dynamically. The motor has F class motor winding insulation and ingress protection rating.

More information

TCDH F400-TCDV F400. Smoke extract - Fire protection SMOKE EXTRACT FANS CENTRIFUGAL BACKWARD ROOF FANS F Application. Range.

TCDH F400-TCDV F400. Smoke extract - Fire protection SMOKE EXTRACT FANS CENTRIFUGAL BACKWARD ROOF FANS F Application. Range. N OU VE A U Approved F400 10 (400 C 10 mn) CE marked Special range for speed variation VAR Easy installation and maintenance Low sound level Electrical accessories and relay box mounted wired New vertical

More information

CODE MODEL 1RC9020 REC PRO 90 S RC9021 REC PRO 90 S RC9022 REC PRO 90 S RC9023 REC PRO 90 S

CODE MODEL 1RC9020 REC PRO 90 S RC9021 REC PRO 90 S RC9022 REC PRO 90 S RC9023 REC PRO 90 S REC PRO 9S High efficiency Heat Recovery Units Non residential applications EFFICIENCY 9% Comply with ErP Directive 125/29/CE and EU Regulation 1253/214. Classification: Non Residential Ventilation Unit

More information

Model METRIC SHAFT WT (LBS) mm mm mm mm mm mm mm 572

Model METRIC SHAFT WT (LBS) mm mm mm mm mm mm mm 572 FEATURES Computer designed, efficient performance, forward curved blower. Blower wheel hub is secured to the shaft with a locking keyway. Blower is secured to anti-vibration mounts within the cabinet.

More information

MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional

MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional Y + U I COADIS COMBI High pressure and high ductable units Motor optional is a non independent air conditioning terminal unit for heating and cooling offices and hotels. With reduced dimensions and designed

More information

ACOUSTIC CABINET FANS CVAB / CVAT Series

ACOUSTIC CABINET FANS CVAB / CVAT Series Range of in-line cabinet fans, manufactured from galvanised steel sheet with double thickness side panels internally lined with 17 mm thickness of fireproof fibreglass acoustic insulation (M). All models

More information

Ultra-quiet circular duct fans TD-SILENT ECOWATT Series

Ultra-quiet circular duct fans TD-SILENT ECOWATT Series TD-SILENT ECOWATT - MODELS 5 to TD-SILENT ECOWATT - MODELS AND At 5% of full speed fan power consumption is reduced by 7% Low profile Mixed-flow fans with sound-absorbent insulation, extremely quiet, fan

More information

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1 X X testregistrierung CAV controllers Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical

More information

CVAB / CVAT Series ACOUSTIC CABINET FANS CVAB / CVAT. Acoustic cabinet fans. Backward curved centrifugal impellers.

CVAB / CVAT Series ACOUSTIC CABINET FANS CVAB / CVAT. Acoustic cabinet fans. Backward curved centrifugal impellers. ACOUSTIC CABINET FANS Series Range of in-line cabinet fans, manufactured from galvanised steel sheet with double thickness side panels internally lined with 17 mm thickness of fireproof fibreglass acoustic

More information

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1 X X testregistrierung CAV controllers Type For the precise control of constant volume flow rates Circular self-powered volume flow controllers for the control of supply air or extract air in constant air

More information

TD-MIXVENT Series IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT. In-Line duct fans

TD-MIXVENT Series IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT. In-Line duct fans IN-LINE MIXED FLOW DUCT FANS Series Range of low profile in-line mixed flow duct fans manufactured in tough reinforced plastic (from 160 to 800 models) or with metal casing steel finished in a tough epoxy-polyester

More information

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1 X X testregistrierung CAV controllers Type For the precise control of normal and high constant volume flows Rectangular self-powered volume flow controllers for the control of supply air or extract air

More information

AXICIAT VA. Axial fans. Smoke extraction F200/120 and F400/120. High available pressure

AXICIAT VA. Axial fans. Smoke extraction F200/120 and F400/120. High available pressure Smoke extraction F200/120 and F400/120 A complete range from 1250 to 95000 m 3 /s High available pressure Blade with variable pitch on stop APPLICATION Extraction or introduction of non-loaded air in the

More information

Centrifugal fan with highly efficient EC drive motor

Centrifugal fan with highly efficient EC drive motor Centrifugal fan with highly efficient EC drive motor simple and safe application and installation 2 Why HLU? 90 years of experience in the plastics processing market More than 10.000 m² production in Germany

More information

ROOF MOUNTED AXIAL FLOW FANS HCTB / HCTT Series

ROOF MOUNTED AXIAL FLOW FANS HCTB / HCTT Series asy to install Supports to facilitate installation in the roof. XTRACTION (type B) SUPPLY (type A) High quality steel sleeve nsuring the long life of the fan. Range of axial roof fans with horizontal air

More information

VENT Series CENTRIFUGAL IN-LINE FANS VENT. In-Line duct fans. Mounting foot

VENT Series CENTRIFUGAL IN-LINE FANS VENT. In-Line duct fans. Mounting foot CENTRIFUGAL IN-LINE FANS Series Range of in-line duct centrifugal fans, manufactured from high grade corrosion resistant pressed galvanised steel and supplied as standard with a pre-wired wiring junction

More information

Product Data. Features/Benefits. 36CBAC,AE,AF,AN, PB,PD,PS Series Active and Passive Chilled Beams. 11 to 190 cfm

Product Data. Features/Benefits. 36CBAC,AE,AF,AN, PB,PD,PS Series Active and Passive Chilled Beams. 11 to 190 cfm Product Data 36CBAC,AE,AF,AN, PB,PD,PS Series Active and Passive Chilled Beams 11 to 190 cfm 36CBAC Chilled beam units offer: An increase in total airflow Sensible cooling and heating options Induction

More information

GigaBox centrifugal fans Product specific information

GigaBox centrifugal fans Product specific information GigaBox centrifugal fans Product specific information GigaBox and accessories Wall bracket GB-WK (ccessories) Outdoor cover hood GB-WSD (ccessories) Included in delivery: a) Flexible sleeve b) Outlet spigot,

More information

CAS 460 2T 7.5. Impeller size motor poles 2=3500 r/min. 60 Hz. Installed power

CAS 460 2T 7.5. Impeller size motor poles 2=3500 r/min. 60 Hz. Installed power CAS CAS: High pressure, single inlet centrifugal fans with sheet steel casing and impeller : High pressure, single inlet centrifugal fans with sheet steel casing and impeller, fitted with acoustic attenuators

More information

VEX500 (Everest XH) High Efficiency Bidirectional Fan Unit

VEX500 (Everest XH) High Efficiency Bidirectional Fan Unit High Efficiency Bidirectional Fan Unit VEX5 (Everest XH) Field of application Installation Advantages Description Range Technical details Aeraulic and electrical details Acoustic specifications Aldes Smart

More information

HEAT-RECOVERY UNITS WITH ENTHALPY/ROTARY HEAT EXCHANGER TECHNICAL MANUAL

HEAT-RECOVERY UNITS WITH ENTHALPY/ROTARY HEAT EXCHANGER TECHNICAL MANUAL UT REC - R HEAT-RECOVERY UNITS WITH ENTHALPY/ROTARY HEAT EXCHANGER TECHNICAL MANUAL 1 CONTENTS GENERAL FEATURES... 3 Scope of the unit... 3 Available configurations... 3 Description of the components...

More information

ACOUSTIC CABINET FANS Centribox CVB-CVT Series, Forward Curved Centrifugal Fans

ACOUSTIC CABINET FANS Centribox CVB-CVT Series, Forward Curved Centrifugal Fans Hacer título más resumido ACOUSTIC CABINET FANS Centribox CVB-CVT Series, Forward Curved Centrifugal Fans Construction Casing The fan casings are manufactured from heavy gauge galvanised sheet steel and

More information

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/ 6/5/EN/6 Circular Silencer Rigid and flexible construction Type CA CB CF CS TROX GmbH Telephone +49/28 45/2 02-0 Telefax +49/28 45/2 02-2 65 Heinrich-Trox-Platz e-mail trox@trox.de D-47504 Neukirchen-Vluyn

More information

HRS. Very high efficiency heat recovery units. from 300 to m³/h >90 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR

HRS. Very high efficiency heat recovery units. from 300 to m³/h >90 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR 4 Lmf Clima 6 FERRARO GROUP HRS Very high efficiency heat recovery units WITH HIGH EFFICIENCY HEAT RECOUPERATOR from 3 to 4. m³/h Air-handling unit designed and manufactured for nonresidential applications,

More information

KAT. DOUBLE INLET CENTRIFUGAL FAN with Forward Wheels

KAT. DOUBLE INLET CENTRIFUGAL FAN with Forward Wheels KAT DOUBLE INLET ENTRIFUGAL FAN with Forward Wheels KAT Series DOUBLE INLET ENTRIFUGAL FAN with Forward Wheels Kruger Ventilation Industries certifies that the KAT series : version S and - model 9-7 to

More information

VARYCONTROL VAV Dual Duct Terminal Boxes

VARYCONTROL VAV Dual Duct Terminal Boxes 5/2/B/3 VARYCONTROL VAV Dual Duct Terminal Boxes for variable volume systems Type TVM Trox (U.K.) Ltd Caxton Way GB-Thetford Norfolk IP24 3SQ Telephone +44 (0)1842 754545 Telefax +44 (0)1842 7051 www.troxuk.co.uk

More information

ACOUSTIC CABINET FANS CENTRIBOX CVB/CVT. Acoustic cabinet fans. Circular duct connection flanges. Flame retardant IP55 remote terminal box

ACOUSTIC CABINET FANS CENTRIBOX CVB/CVT. Acoustic cabinet fans. Circular duct connection flanges. Flame retardant IP55 remote terminal box ACOUSTIC CABINET FANS CENTRIBOX CVB / CVT Series Cabinet fans manufactured from heavy gauge galvanised steel sheet and internally lined with melamine foam flame retardant acoustic insulation (M1). All

More information

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw Air-to-Water Reverse Cycle Heat Pumps SLH 1202 to 3804 With Screw Compressors 261 to 775 kw 287 to 853 kw Technical Brochure TM SLH-A.2GB Date : November 2004 Supersedes : TM SLH-A.1GB/05.04 Design Features

More information

Fan coil unit NBS 100/150

Fan coil unit NBS 100/150 Fan coil unit /150 Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Advantages...3

More information

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K .1 X X testregistrierung CAV controllers Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical

More information

CMTE. Tangential Fan Coil Series with Electronic Controlled Motor

CMTE. Tangential Fan Coil Series with Electronic Controlled Motor Tangential Fan Coil Series with Electronic Controlled Motor Designed by Very Low Electric Energy Consumption High Efficiency Extremely Low Noise Level Infra Red Remote Control Step-less Fan Speed Control

More information

400ºC/2h centrifugal roof fans with horizontal or vertical air outlet CHT 200 4T BS. Installed capacity

400ºC/2h centrifugal roof fans with horizontal or vertical air outlet CHT 200 4T BS. Installed capacity 400ºC/2h centrifugal roof fans with horizontal or vertical air outlet : 400ºC/2h centrifugal roof fans with horizontal air outlet, hood in aluminium : 400ºC/2h centrifugal roof fans with vertical air outlet,

More information

TD-SILENT Series (160 to 1000 models)

TD-SILENT Series (160 to 1000 models) IN-LINE MIXED LOW DUT ANS ultra-quiet Series (1 to models) Low profile Mixed-flow fans with sound-absorbent insulation. Extremely quiet. ertified of Approval Noise Abatement Society (TD-3, TD-, TD-8 and

More information

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1 X X testregistrierung CAV controllers Type Adjustment scale ATEX-Zertifizierung For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) Circular, mechanical self-powered

More information

MAJAX-2 GENERAL SPECIFICATION

MAJAX-2 GENERAL SPECIFICATION MAJAX-2 GENERAL SPECIFICATION Majax-2 axial flow fans are manufactured in diameters ranging from 315mm to 2000mm (available in 2250mm on request), and incorporate manually adjustable pitch aluminium bladed

More information

BPF. Centrifugal Plug Fans

BPF. Centrifugal Plug Fans BPF Centrifugal Plug Fans Introduction INTRODUCTION Plug Fans S&P - THE COMPANY Soler & Palau was founded in 1951 in Ripoll (Spain) and since this date has become one of the world s leading companies engaged

More information

CBM Small Series LOW PRESSURE CENTRIFUGAL FANS. CBM Small. Low pressure centrifugal fans. Impeller dynamically balanced.

CBM Small Series LOW PRESSURE CENTRIFUGAL FANS. CBM Small. Low pressure centrifugal fans. Impeller dynamically balanced. LOW PRESSURE CENTRIFUGAL FANS CBM Small Series Range of single and double inlet direct driven low pressure centrifugal fans manufactured from galvanised sheet steel and protected against corrosion by a

More information

series Silencers

series Silencers series SK Silencers www.koolair.com Series SK 1 Silencers CONTENTS ASK-1 and ASK-2 Round Silencers Description 4 ASK-1 Overall Dimensions 5 ASK-2 Overall Dimensions 6 Selection Table and Weights 7 ASK-1

More information

CONTRA ROTATING CASED AXIAL FANS TCBBx2 / TCBTx2 Series

CONTRA ROTATING CASED AXIAL FANS TCBBx2 / TCBTx2 Series Range of cylindrical cased axial fans fitted with aluminium impellers and manufactured from high grade rolled galvanised steel and protected against corrosion by cataforesis primer and black polyester

More information

Dynamically-balanced impellers with extremely robust cores CMP T 5.5

Dynamically-balanced impellers with extremely robust cores CMP T 5.5 Medium pressure, single inlet centrifugal fans with sheet steel casing and impeller Fan: Sheet steel casing. Forward-curved impeller made of galvanised sheet steel. 38-2M model casing in cast aluminium.

More information

CLOSE CONTROL UNITS WITH CHILLED WATER COIL

CLOSE CONTROL UNITS WITH CHILLED WATER COIL CLOSE CONTROL UNITS WITH CHILLED WATER COIL COOLING CAPACITY FROM 5 TO 154 kw 230 D 56 The range of chilled water close control units, series, is particularly indicated for use in technological centres,

More information

Everest XV. ErP. High Efficiency HRV Fan Unit READY

Everest XV. ErP. High Efficiency HRV Fan Unit READY High Efficiency HRV Fan Unit ErP READY Field of application Installation Advantages Description Range Technical details Aeraulic and electrical details Acoustic specifications Aldes Smart Control system

More information

CJBX CJBX/AL. Options. Order code CJBX 15/15 4. Technical characteristics

CJBX CJBX/AL. Options. Order code CJBX 15/15 4. Technical characteristics CJBX CJBX/AL CJBX: Belt-driven acoustically-insulated ventilation units. CJBX/AL: Belt-driven ventilation units with aluminium profiles and prefinished sheet steel and acoustic insulation. CJBX Options

More information

CBM Series LOW PRESSURE CENTRIFUGAL FANS CBM. Low pressure centrifugal fans. Impeller dynamically balanced. Anti-vibration mounts

CBM Series LOW PRESSURE CENTRIFUGAL FANS CBM. Low pressure centrifugal fans. Impeller dynamically balanced. Anti-vibration mounts LOW PRESSURE CENTRIFUGAL FANS Series Range of double inlet direct driven low pressure centrifugal fans manufactured from galvanised sheet steel. All the models are fitted with forward curved centrifugal

More information

Centrifugal performance characteristics with axial flow pattern: RADAX VAR

Centrifugal performance characteristics with axial flow pattern: RADAX VAR High pressure in-line mixed-flow fans RADAX VAR Centrifugal performance characteristics with axial flow pattern: RADAX VAR COMPACT PRESSURE-RESISTANT UNIVERSAL In their compact casing, the RADAX VAR impellers

More information

Square Duct Fans - ESTOC Range. Estoc Features. Electrical Supply. Product Code. Sizes 355, 400, 450, 500, 560, 630 and 710.

Square Duct Fans - ESTOC Range. Estoc Features. Electrical Supply. Product Code. Sizes 355, 400, 450, 500, 560, 630 and 710. Square Duct Fans - ESTOC Range Features Sizes from 355 to 71 mm diameter Air flow 1,9 m 3 /h (5.2 m 3 /s) Static pressures up to 115 Pa Maximum temperature from +4 C to +7` C (depending on the model) Adjustable

More information

Tube Fans - ROPERA Range ROPERA 100 (L) Features. Electrical Supply. Product Code. Sizes 100, 125, 150, 160, 200, 250, 315 and 355.

Tube Fans - ROPERA Range ROPERA 100 (L) Features. Electrical Supply. Product Code. Sizes 100, 125, 150, 160, 200, 250, 315 and 355. Tube Fans - ROPERA Range Features 1 mm to 355 mm diameter Air flow 234 m 3 /h (.65 m 3 /s) Static pressures up to 92 Pa Casing - galvanized sheet steel Backward curved impeller Easy electrical connection

More information

Mixed Flow Roof Fans (RMH)

Mixed Flow Roof Fans (RMH) Mixed Flow Roof Fans (RMH) Motors protected to IP44 Motor insulation Class B Maximum operating temperature 4 C Standard Thermal Overload Protection IP65 service isolator Bird guard included as standard

More information

ULTRA LOW ENERGY. VHR Void Series W/I/s TOTAL SFP Typical. Made in the UK. VHR Void Mounted Heat Recovery Units VHR PERFORMANCE OVERVIEW:

ULTRA LOW ENERGY. VHR Void Series W/I/s TOTAL SFP Typical. Made in the UK. VHR Void Mounted Heat Recovery Units VHR PERFORMANCE OVERVIEW: VHR Void Mounted Heat Recovery Units TM.72 W/I/s TOTAL SFP Typical General: Units shall be manufactured from high quality galvanized sheet steel with stainless steel drain trays, acoustic, non-hygroscopic

More information

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems MIXVENT TD / MIXVENT TD-T MIXVENT TDx2 ACCESSORIES Description Range Construction The MIXVENT system has been designed to compliment the MIXVENT-TD range

More information

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX) X X testregistrierung CAV controllers Type Adjustment scale For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX) Rectangular, mechanical self-powered

More information

CJBD/ALF CJBX/ALS CJBX/ALF CJBD/ALS VENTILATION UNITS WITH ALUMINIUM PROFILES. According EU Regulation

CJBD/ALF CJBX/ALS CJBX/ALF CJBD/ALS VENTILATION UNITS WITH ALUMINIUM PROFILES. According EU Regulation CJBD/AL CJBD/ALS CJBD/ALF CJBX/AL CJBX/ALS CJBX/ALF VENTILATION UNITS WITH ALUMINIUM PROFILES According EU Regulation CJBD/AL CJBD/ALS CJBD/ALF CJBD/AL: Soundproofed ventilation units with profiles in

More information

Parts and characteristics

Parts and characteristics Type TVZ FOR SUPPLY AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS VAV terminal units for the supply air control in buildings with variable air volume systems and demanding acoustic requirements Highly

More information

NEW Slimpak EC Box Fan (SLPT EC)

NEW Slimpak EC Box Fan (SLPT EC) NEW Slimpak EC Box Fan (SLPT EC) Compact low profile design Duct Sizes 100 500mm Performance - Airflow 0.01 to 1.2m 3 /s, Pressure up to 650Pa Latest energy saving EC/DC motors Internal mounting IPX2 Manufactured

More information

Square Mixed Flow Fans (MFQ)

Square Mixed Flow Fans (MFQ) Square Mixed Flow Fans (MFQ) Features and Benefits Motors protected to IP44 Motor insulation Class B Maximum operating temperature +40 C Standard Thermal Overload Protection Sizes 400 to 500 3 phase are

More information

Ductable Modular Fan Coil Unit VPX. Technical Brochure TM VPX-W.2GB Date : May 2004 Supersedes : TM VPX-W.1GB/08.03

Ductable Modular Fan Coil Unit VPX. Technical Brochure TM VPX-W.2GB Date : May 2004 Supersedes : TM VPX-W.1GB/08.03 Ductable Modular Fan Coil Unit VPX Technical Brochure TM VPX-W.2GB Date : May 2004 Supersedes : TM VPX-W.1GB/08.03 Design Features Presentation The VPX fan coil unit has been specially designed to meet

More information

UMXCA/UMXCBA ECVA/ECVBA

UMXCA/UMXCBA ECVA/ECVBA OUTDOOR UNITS Models: 801.1 1001.1 1201.1 1501.1 1602.2 2002.2 2402.2 3002.2 3502.2 4002.2 4502.2 Cooling Capacities: from 25,9 kw to 134,7 kw Heating Capacities: from 27,3 kw to 142,4 kw INDOOR UNITS

More information

Sentinel D-Box Twin Fan

Sentinel D-Box Twin Fan Sentinel D-Box Twin Fan Duct Sizes mm Performance - Airflow.1 to 1.3m 3 /s, Pressure up to 65Pa Sentinel demand ventilation fan controller with lockable isolator Latest energy saving EC/DC motors Aluzinc

More information

ROOF MOUNTED FANS TH-MIXVENT Series Mixed Flow Fans TH-MIXVENT. Roof mounted fans. Flame retardant terminal box. Circular spigot coupling

ROOF MOUNTED FANS TH-MIXVENT Series Mixed Flow Fans TH-MIXVENT. Roof mounted fans. Flame retardant terminal box. Circular spigot coupling ROOF MOUNTED FNS Series Mixed Flow Fans P P L I T I O N S Workshops ommercial premises Offices Restaurants and cafes Wine cellars asements Range of roof mounted mixed flow fans supplied as standard for

More information

HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM

HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM 1 Lmf Clima 216 FERRARO GROUP HPR Heat recovery units HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM from 7 to 23. m³/h Supporting structure in extruded aluminium profiles and curtain

More information

Heat recovery ventilators with rotating exchanger, automatic control and EC motor, designed for vertical ducts and installation in technical room

Heat recovery ventilators with rotating exchanger, automatic control and EC motor, designed for vertical ducts and installation in technical room RIRS V EKO Heat recovery ventilators with rotating exchanger, automatic control and EC motor, designed for vertical ducts and installation in technical room Common characteristics: Efficient low-noise

More information

Variable Air Volume Dampers

Variable Air Volume Dampers OVAV 2000 SERIES OPTIMA VAV DAMPERS Overview OPTIMA make Variable Air Volume (OVAV) box is a part of an Air Conditioning system. It is located inside the duct work. VAV Dampers are designed to control

More information

TD-ECOWATT AND DECOR-ECOWATT Series

TD-ECOWATT AND DECOR-ECOWATT Series S&P presents its new ranges of domestic and commercial fans with DC motors TD-ECOWATT AND DECOR-ECOWATT Series Up to 55% savings in energy consumption Reduced CO 2 emissions Improvement of the environment

More information

CENTRIFUGAL IN-LINE FANS VENT Series

CENTRIFUGAL IN-LINE FANS VENT Series Range of in-line duct centrifugal fans, manufactured from high grade corrosion resistant pressed galvanised steel and supplied as standard with a prewired wiring junction box and a robust mounting foot.

More information

Fan coil units MAJOR 2 CV/CH

Fan coil units MAJOR 2 CV/CH CH 41 D CV 1 D MAJOR 2: Design and performance HEE impeller for increased performance Motor optional MAJOR 2 is a non-independant chilled and/or hot water supplied air conditioning Comfort unit for the

More information

CAV controllers Type RN

CAV controllers Type RN 2.1 X X testregistrierung CAV controllers Type For the precise control of constant volume flow rates Circular self-powered volume flow controllers for the control of supply air or return air in constant

More information

VERSO-CF H-PM/IE5/2/2-F7-M5-HW/4R/2.6-X-R1-C5.1-X

VERSO-CF H-PM/IE5/2/2-F7-M5-HW/4R/2.6-X-R1-C5.1-X Date: 08.06.2018 Price: 13121 EUR without VAT, W Vilnius Air handling unit model: VERSO-CF-30-2.6-H-PM/IE5/2/2-F7-M5-HW/4R/2.6-X-R1-C5.1-X TECHNICAL SPECIFICATION AHU size 30 Typology NRVU BVU of HRS other

More information

Voltage 400V 3N 50Hz. L W H Weight Fans Surface. Air Flow [m 3 /h] Primary [m 2 ] Ø [mm]

Voltage 400V 3N 50Hz. L W H Weight Fans Surface. Air Flow [m 3 /h] Primary [m 2 ] Ø [mm] Open condensing units with air condenser and semi-hermetic compressor Galvanized and painted in RAL7035 base Semi-hermetic compressor Air condenser unit with 4 poles fans 230/1 Vibration absorber on discharge

More information

Type MSA. Splitter thickness 200 mm FOR INCREASED INSERTION LOSS AND BROADBAND ATTENUATION EVEN IN THE LOW FREQUENCY RANGE

Type MSA. Splitter thickness 200 mm FOR INCREASED INSERTION LOSS AND BROADBAND ATTENUATION EVEN IN THE LOW FREQUENCY RANGE Homepage > Products > Sound attenuators > Splitter sound attenuators > Type MSA Type MSA Splitter thickness 200 mm FOR INCREASED INSERTION LOSS AND BROADBAND ATTENUATION EVEN IN THE LOW FREQUENCY RANGE

More information

ITEC High Efficiency EC Twin Fan for convenient fitting and full control. Casing constructed from 1.6mm Galvanised sheet steel

ITEC High Efficiency EC Twin Fan for convenient fitting and full control. Casing constructed from 1.6mm Galvanised sheet steel ITEC High Efficiency EC Twin Fan for convenient fitting and full control Casing constructed from 1.6mm Galvanised sheet steel Circular spigot connection Inline for ease of fitting into duct system Single

More information

supplied in Form (B) configuration. Airflow over Impeller- Motor.

supplied in Form (B) configuration. Airflow over Impeller- Motor. CYLINDRICAL CASED AXIAL FLOW FANS COMPACT Series TCBB-TCBT (Aluminium impellers) and TCFB-TCFT (Plastic impellers) NEW VERSIONS Description The S&P Cylindrical Cased Axial Fans feature, as the name suggests,

More information

5/9.2/EN/6. Volume Flow Limiter. Type VFL for insertion into air ducting. The art of handling air

5/9.2/EN/6. Volume Flow Limiter. Type VFL for insertion into air ducting. The art of handling air 5/9.2/EN/6 Volume Flow Limiter Type VFL for insertion into air ducting The art of handling air Contents Description 3 Dimensions 3 Nomenclature 4 Technical data 4 Acoustic data 4 Installation notes 5 Order

More information

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

VAV terminal units. Type TVM. For dual duct systems PD TVM 1 X X testregistrierung VAV terminal units Type Variant -S Rectangular connection on the room end For dual duct systems VAV dual duct terminal units for dual duct systems with variable volume flows in buildings

More information

series RVV Variable flow rate controllers

series RVV Variable flow rate controllers series RVV Variable flow rate controllers www.koolair.com Series RVV 1 CONTENTS Variable flow rate controllers, type RVV Description 2 Dimensions and product code 3 Selection tables 4 Variable flow rate

More information

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series Range of low profile in-line mixed flow duct fans manufactured in tough reinforced plastic (from to models) or with metal casing steel finished in a tough epoxy-polyester paint coating (from to models).

More information

HEAT RECUPERATORS WITH AIR-AIR CROSS FLOW

HEAT RECUPERATORS WITH AIR-AIR CROSS FLOW OVERVIEW AND CONSTRUCTION DETAILS OVERVIEW : The series of heat recuperators are fitted with a highly efficient air-air heat exchanger that makes it possible to reuse a significant amount of the heat present

More information

IN-LINE CENTRIFUGAL DUCT FANS VT Series

IN-LINE CENTRIFUGAL DUCT FANS VT Series IN-LINE CENTRIFUGAL DUCT FANS VT Series DESCRIPTION The VT series of circular in-line duct centrifugal fans consists of model variations within nominal model sizes of,,,,, and mm respectively. The VT range

More information

Industry best 5 year fan housing warranty, 1 year motor warranty

Industry best 5 year fan housing warranty, 1 year motor warranty MEL FEATURES Exhaust air up to 28,000 CFM in high static pressure applications up to 1-1/4 w.g. Attractive spun aluminum exterior Belt drives permit easy performance adjustments when needed Non-overloading

More information