1 System Components for Sample Gas Sampling Data Sheet 10/ EN November 2004 A gas analysis system usually consists of two groups of devices: The gas analyzer measures the concentrations of the sample gas components and converts them into an electrical signal. Supplementary devices sample the sample gas from the process, condition it and feed it in the gas analysis system. In most cases, the sample gas sampled from the process cannot be processed by the gas analyzer without further conditioning. Too high a dust content, temperature and dew point as well as too high or too low pressure, and not least interference components in the sample gas can impair the operational capability of the gas analyzer and falsify the measuring result. Supplementary devices such as the sampling probe, the sample gas line, the sample gas cooler and pumps and filters ensure that the sample gas inlet conditions of the connected gas analyzers are satisfied and faultless measuring results are obtained independently of the process sequence and the local conditions. Contents Page Modular Sample Gas Probe System 3 FE2 Filter Unit 4 Annular Heating Element 5 Heating Sleeve 6 PFE2 Filter Unit 7 PFE3 Filter Unit 14 Selection Table for Probe Tube Types and Probes 16 Type 40 Probe Tube 17 Type 42 Probe Tube (heated) 18 Type 60 Probe Tube (Cement Flue Gas Probe) 19 Probe 2 20 Probe 1, Probe Ceramic Filter 22 Process Pressure Reducers 23 Heated Sample Gas Lines 25 CGWB 13 Heated Sample Gas Line 26 TBL 01, TBL 01-E Heated Sample Gas Lines 28 Electronic Temperature Controller and Switching Relay 30

2

3 Modular Sample Gas Probe System Easily adaptable to different sampling conditions thanks to modular construction Components: FE2, PFE2, PFE3 filter units Probe tube types K, 40, 42, 60 Annular heating element Heating sleeve Probe tubes and filter unit heatable Connections for test gas and purging Filter with high retention rate and long service life Easy filter replacement Usable in emission measuring systems conforming to 13th BImSchV and 17th BImSchV (Federal Immission Protection Law) 10/ EN November 2004 System Components for Sample Gas Sampling 3

4 FE2 Filter Unit Use The FE2 filter unit is a component of the modular gas sampling probe system. It is used for filtering gases containing dust. Process Gas Sampling Conditions Pressure p abs = 50 to 600 kpa Temperature max. 200 C (coated max. 180 C) Flow Rate 30 to 500 l/h, relative to 100 kpa and 0 C Pressure Drop approx. 0.6 hpa at 100 l/h Dust Content max. 3 g/m 3 (application recommendation); max. 40 g/m 3 with probe tube type 40 with blow-back device; max g/m 3 with probe tube type 60 Filter Characteristics Filter Element Surface filter Filter Fineness 0.5 µm Retention Rate % Seal Integrity 10 4 hpa l/s Dead Volume 280 ml Materials of the Gas-carrying Parts Casing and Connections Special steel Mat. No Flange Special steel Mat. No (optionally special steel Mat. No ) Filter Aluminum oxide surface filter Coating Thermoset plastic, resistant up to 180 C Connection Ports Sample Gas/Test Gas G 1/4 internal thread to DIN ISO 228/1 Compressed Air (2 Ports) G 1/2 internal thread to DIN ISO 228/1 Probe Tube G 3/4 internal thread to DIN ISO 228/1 Compressed Air Supply for Blowback (See PFE2 Filter Unit, page 7) Instrument Air Free of dust, water and oil Pressure max. 600 kpa Ordering Information Catalog No. Housing and flange SS Housing and flange SS, coated Housing and flange SS, filt. fineness 0.3 µm Installation Flange DN 65, PN 6, Form B to DIN 2573, flange gasket A; positioning of holes: 0, 45, 90, 135, 180, 225, 270, 315, 360 Mounting Flange connect or bolt to the probe tube Weight approx. 8.0 kg 4 System Components for Sample Gas Sampling 10/ EN November 2004

5 Annular Heating Element Use For heating the FE2 filter unit, which is a component of the modular gas sampling probe system. Heating is necessary if condensation is likely from moist gases and there is consequently risk of the filter becoming clogged and corroded. Data Power Supply 115 V AC or 230 V AC, 50 to 60 Hz Heater Output 200 W, 100 W or 50 W depending on setting The heating resistors are factory-set for heat output of 100 W Temperature of Heater (unregulated) approx. 120 C to 180 C (measured at ambient temperature of 20 C, still air) Ambient Temperature 0 to 55 C (still air) Degree of Protection of Housing IP 50 Materials Housing: aluminum alloy, heating surface: brass Weight approx. 1.7 kg Electrical Connections Terminals via cable gland PG 13.5 The electrical supply conductor must be heat resistant ( 200 C). Dimensional Drawing (dimensions in mm) Installation Two half shells are placed round the FE2 filter unit to be heated and closed with a wing screw. Option Regulated Heating with 1 x Pt 100 Ordering Information Catalog No. Ring heater 230 V, 50/60 Hz Ring heater 115 V, 50/60 Hz Ring heater with Pt 100, 230 V, 50/60 Hz Ring heater with Pt 100, 115 V, 50/60 Hz Heating Circuit 230 / 115 V AC 230 / 115 V AC 230 / 115 V AC 200 W 100 W 50 W 10/ EN November 2004 System Components for Sample Gas Sampling 5

6 Heating Sleeve Regulated Heating Sleeve for FE2 Filter Unit Heater Micanite Holding Temperature max. 350 C Temperature Control max. 200 C (Pt 100) Power Supply 230 V AC, optionally 115 V AC Power Consumption 250 VA Connection Terminal box with PG 9 bolted connection, protection level IP 54 Supply Cable 3 x 1 mm 2 with silicone sheath, length 1 m Ambient Temperature 20 to +45 C Relative Humidity 75 % yearly mean; infrequent slight condensation permissible Weight approx. 1 kg Essential Accessories Insulating Mat Temperature Controller (see page 30) Ordering Information Catalog No. Heated sleeve, 230 V, 50/60 Hz, 300 VA Heated sleeve, 115 V, 50/60 Hz, 300 VA Isolation for heated sleeve System Components for Sample Gas Sampling 10/ EN November 2004

7 PFE2 Filter Unit Use The PFE2 filter unit consists of the FE2 filter unit with a regulated heating sleeve, installed in a special-steel protective case. It is used to filter dust-containing gases and is a component of the modular gas sampling probe system. When used for gases with high dust content, the PFE2 can optionally be fitted with valves for automatic cleaning of the filter element in the FE2 filter unit. Protective Case Dimensions 450 x 450 x 400 mm (H x W x D) Material Special steel, Mat. No Degree of Protection of Housing IP 54 Ambient Temperature 20 to +45 C Weight approx. 18 kg Options Heating sleeve, regulated (Pt 100), with insulating mat Annular heating element, unregulated Filter fineness 0.3 µm Pneumatic Valve Diaphragm Valve 2/2-way straight-way valve Operating Pressure/Control Pressure 600 kpa (6 bar) Nominal Diameter DN 12 Connections G 1/2 internal thread DIN ISO 228/1 Control air: G 1/8 internal thread DIN ISO 228/1 Material Brass Mode of Operation Closed in the normal position Ambient Temperature 0 to +100 C Control Valve Solenoid Valve 3/2-way solenoid valve Nominal Diameter DN 2.0 Pressure Range 600 kpa (6 bar) Connections G 1/8 internal thread DIN ISO 228/1 Material Brass Electrical Connections Standard connector Power Supply 115 V AC or 230 V AC, 50 to 60 Hz Power Consumption 8 VA Mode of Operation Closed in normal position Ambient Temperature 0 to +100 C 10/ EN November 2004 System Components for Sample Gas Sampling 7

8 PFE2 Filter Unit Ordering Information Catalog No Design without protection box 1 with protection box IP 54 (450 x 450 x 400 mm) 2 with protection box, IP 54, anti-freeze heating 3 with protection box, IP 54, ambient temp. max. 65 C 4 with protection box IP 54 (330 x 203 x 270 mm) 5 Filter housing (equal FE 2) Housing and flange SS 3 Housing and flange SS, coated 4 Housing and flange SS, with filter element <0.3 µm (filtration fineness) 7 Housing and flange SS, coated, with filter element <0.3 µm (filtration fineness) 8 Heating Without 1 with heating unit and insulation (max. 200 C) 2 with ring heater, unregulated 3 Control / Monitoring Without 1 with 1x Pt with 2x Pt Back purging unit (without compressed air unit) without reverse purging 0 with pneumatic valve 1 with 3x pneumatic-, 1x air-bleed-valve(s) 2 with check valve for AC-FNT 3 Power supply 230 V, Hz V, Hz 2 Catalog No System Components for Sample Gas Sampling 10/ EN November 2004

9 PFE2 Filter Unit Probe Protective Case Dimensional Diagram (dimensions in mm) Sample gas connection Electrical connections Compressed air Purging Bulkhead fitting 10/12x1 mm Test gas connection Bulkhead fitting 4/6x1 mm Control air Bulkhead fitting 4/6x1 mm Cover swivels upwards Elongated holes for M8 safety collar bolts Flange plate with pipe clamp 2 1/2" RST 37-2 hot galvanized DIN 3568 for mounting at probe mounting adapter Take holes for cable glands on the left into account Terminal box with cable glands Use as required 2x Pg21 3x Pg16 1x Pg13,5 1x Pg11 10/ EN November 2004 System Components for Sample Gas Sampling 9

10 PFE2 Filter Unit Dimensional Drawing: Mounting of Probe Protective Case with PFE2 Filter Unit (dimensions in mm) X α Minimum distance x min of the mounting flange from the wall depending on mounting angle α: α x min /mm PFE2 Filter Unit: Pneumatics Connections for 2-Stage Back-Purging 1 Terminal box 2 Probe protective case 3 B Bulkhead fitting compressed air 4 to 6 bar 4 E Plug (test gas connection) 5 Pilot valve, filter cleaning -Y2.1 6 Diaphragm valve, filter cleaning -Y2.2 7 C Sample gas connection 8 Pilot valve, pulsed compressed air -Y1.1 9 Diaphragm valve, pulsed compressed air -Y Bulkhead fitting 6 mm control air 2 6 bar 11 Bulkhead fitting 12 mm compressed air 4 6 bar 12 Heated sample gas line 13 Power supply for heated sample gas line 14 FE2 filter unit 15 Solenoid valve, venting -Y4 16 Diaphragm valve, tube and filter surface cleaning -Y Pilot valve, tube and filter surface cleaning -Y System Components for Sample Gas Sampling 10/ EN November 2004

11 PFE2 Filter Unit Probe Protective Case, PFE2 Filter Unit Terminal Diagram, Terminal Block -X1 (Standard) Probe protective case Terminal box, strip -X1 1 1st Pt 100 FE2 filter unit 2 3 Pt 100 three wire connection IEC 751 Cl. B 4 1st Pt 100 Type 42 probe tube 5 6 Pt 100 three wire connection IEC 751 Cl. B 7 8 2nd Pt 100 FE2 filter unit (fail safe circuit) 9 10 Pt 100 three wire connection IEC 751 Cl. B 11 2nd Pt 100 Type 42 probe tube (fail safe circuit) Pt 100 three wire connection IEC 751 Cl. B 14 Heater FE2 filter unit L N PE V Hz or 115 V Hz Heater Type 42 probe tube L N L N Heater Type 42 probe tube PE N PE V 115 V Hz Hz N 22 PE 23 PE 23 10/ EN November 2004 System Components for Sample Gas Sampling 11

12 PFE2 Filter Unit Probe Protective Case, PFE2 Filter Unit Terminal Diagram, Terminal Block -X2 (Standard) Probe protective case Terminal box, strip -X2 1st Pt 100 sample gas line Pt 100 three wire connection IEC 751 Cl. B 2nd Pt 100 sample gas line (fail-safe circuit) Pt 100 Three wire connection IEC 751 Cl. B 7 Heater sample gas line wattage acc. to length max W L N PE V Hz or 115 V Hz Anti-frost heater for system shut down approx. 5 C at ambient temperature -20 C 30 W Internal temperature approx. 100 C Use heat-resistant cables! L N PE V Hz or 115 V Hz The heater operates unregulated. Switch on from outside only when system shut down 12 System Components for Sample Gas Sampling 10/ EN November 2004

13 PFE2 Filter Unit Probe Protective Case, PFE2 Filter Unit Terminal Diagram, Terminal Block -X3 (for Cleaning) Probe protective case Terminal box, strip -X3 Pilot valve -Y2.1 filter cleaning Extended cleaning Pilot valve -Y3.1 cleaning of filter surface and tube A A R P R P L PE N L PE N V Hz or 115 V Hz L PE N Pilot valve -Y1.1 Pulsed compr. air A R P L PE N Pilot valve -Y4 Venting R P B L PE N Probe / flange PE PE 9 9 Internal temp. approx. 100 C Use heat-resistant cable Remove with equipotential bonding 10/ EN November 2004 System Components for Sample Gas Sampling 13

14 PFE3 Filter Unit Design The PFE3 filter unit consists of a modified FE2 filter unit with a self-regulating heater. It is installed in a stainless steel protective case. Process Gas Sampling Conditions Pressure p abs = 50 to 600 kpa Temperature max. 200 C Flow Rate 30 to 500 l/h, relative to 100 kpa and 0 C Pressure Drop approx. 0.6 hpa at 100 l/h Dust Content max. 3 g/m 3 (application recommendation) Filter Characteristics Filter Element Surface filter Filter Fineness 0.5 µm (optional 0.3 µm) Seal Integrity 10 4 hpa l/s Dead Volume 280 ml Dimensions 50/20 x 135 mm Heater Type Self-regulating heater (400 W) Temperature 180 C (ambient temperature 20 C) Temperature Alarm approx. 150 C Power Supply 110 to 240 V AC Option Annular heating element (see page 5) Materials of the Gas-carrying Parts Casing, Flange and Connections Special steel Mat. No Seals Viton Installation Flange DN 65, PN 6, Form B to DIN 2527; positioning of holes: 45, 135, 225, 315 Mounting Flange connect or bolt to the probe tube Connection Ports Sample Gas Pipe fitting 6 mm Test Gas Bulkhead fitting 6 mm (option) Probe Tube G 3/4 internal thread to DIN ISO 228/1 Protective Case Dimensions 270 x 203 x 330 mm (H x W x D) Material Special steel Mat. No Degree of Protection of Case IP 54 Weight approx. 17 kg Ambient Temperature 20 to +45 C 14 System Components for Sample Gas Sampling 10/ EN November 2004

15 PFE3 Filter Unit Dimensional Drawing, Gas Connections (dim. in mm) Electrical Connections PE PE 5 2x M x M20 2x M16 1 Test gas connection (optional) 6 mm bulkhead fitting 2 Sample gas connection 6 mm pipe fitting 3 Check valve for ACF-NT (optional) 1 Heater for filter 2 Heater for sample gas line 3 Pt 100 (optional) 4 Pt 100 sample gas line 5 Temperature monitor Ordering Information Catalog No Design with protection box IP 54 (330 x 203 x 270 mm) 1 with protection box IP 54 (330 x 203 x 270 mm) and check valve for ACF-NT 2 Filter housing (without connections for back purging) Housing and flange stainless steel (filtration fineness 0.5 µm) 2 Housing and flange stainless steel, with filter element <0.3 µm (filtration fineness) 4 Heating With self-regulating heating and temperature alarm (110/220 V, AC) 1 with ring heater unregulated 2 Power supply 230 V AC V AC 2 Catalog No / EN November 2004 System Components for Sample Gas Sampling 15

16 Selection Table for Probe Tube Types and Probes Probe tube type 40 SS Probe tube type 40 SS coated Probe tube type 40 SS Probe tube type 40 silicone carbide Probe tube type 42 SS heated Probe tube type 60 water cooled Probe 2 unheated Probe 2 heated Probe 2 partially heated Probe 60 S water cooled Probe H water cooled Max. temperature Dust content < 130 C 2) < 180 C 2) C C 1300 C 1400 C < 50 mg/m 3 < 1000 mg/m 3 < 3 g/m 3 Water vapor < 65 C dew point > 65 C Acidic aerosols (acid dew pt. 130 C) > 3 g/m 3 1) 1) 1) 1) g/m 3 1) 1) 1) 1) 1) 1) 2000 g/m 3 1) 1) 1) Flow velocity < 10 m/s > 10 m/s Technical data see... p. 17 p. 17 p. 17 p. 17 p. 18 p. 19 p. 20 p. 20 p. 20 3) 3) 1) Back purging required 2) with regulated heating sleeve 3) ACK Cement Analysis System data sheet (Document No. 10/ EN) Lead-Through Tube Installation Brickwork with metal sheeting Isolated sheet-metal channel Brickwork α Flow direction of process gas 1 Lead-through tube 2 Mounting flange DN 65, PN 6, Form B to DIN Gasket 4 Welded-on rectangular block 5 Sampling probe flange Minimum distance x min of the mounting flange from the wall depending on mounting angle α: α x min /mm Dimensions in mm 16 System Components for Sample Gas Sampling 10/ EN November 2004

17 Type 40 Probe Tube Use For sampling hot dust-containing gases in conjunction with the FE2/PFE2 filter unit Dimensional Drawing (dimensions in mm) Special Steel Material No (max. 450 C) Process Gas Sampling Conditions Pressure p abs = 50 to 500 kpa (0.5 to 5 bar) 12,6 ø 17,2 ø G3/4 Temperature SS Mat. No max. 450 C SS Mat. No (coated) max. 180 C SS Mat. No max. 900 C Silicone carbide (max. length mm) max C L1 16 Special Steel Material No (max. 900 C) Flow Rate Pressure Drop max. 300 l/h approx. 10 hpa at 30 to 90 l/h 16,8 ø 21,4 ø G3/4 Dust Content max. 3 g/m 3 (application recommendation); max. 40 g/m 3 with blow-back device in conjunction with FE2/PFE2 filter unit Installation L1 Silicon-Carbide (max C) SiC Protective Tube 16 G 3/4 external thread DIN ISO 228/1 Mounting Angle any; 8 to 90 downwards from the horizontal is recommended. It is imperative to install the silicon carbide probe tube vertically. 15 ø 23 ø ø L1 16 G3/4 Ordering Information Catalog No Version Stainless steel (1.4571), up to 500 C 1 Stainless steel (1.4571), coated, up to 180 C 2 Silicon carbide up to 1300 C, max mm 4 Stainless steel (1.4893), up to 900 C 5 Stainless steel (1.4571), up to 300 C, heated (for cement) 6 Nominal length 500 mm mm mm mm mm mm (only for heated version) mm (only for heated version) mm (only for heated version) 8 Catalog No / EN November 2004 System Components for Sample Gas Sampling 17

18 Type 42 Probe Tube (heated) Use Low gas temperature High moisture content in gas Corrosive components in the process gas Typical places of use are: Sampling points in wet desulphurization plants (crude gas, clean gas, part-cleaned clean gas) Waste incineration plants Auxiliary boilers and stack emission measurements Process Gas Sampling Conditions Pressure p abs = 200 kpa (2 bar) Temperature < 200 C Flow Rate max. 250 l/h Flow Velocity max. 12 m/s (> 1000 mm max. 7 m/s) Dust Content max. 3 g/m 3 (application recommendation); max. 40 g/m 3 with blow-back device in conjunction with FE2/PFE2 filter unit T 90 Time approx. 0.4 s at 250 l/h Probe Tube Heater Heat Output nominal length mm: 2 x 200 W nominal length mm: 2 x 300 W nominal length mm: 2 x 400 W Nominal Voltage 230 V/115 V AC, 50 to 60 Hz Control Control temperature max. 200 C Temperature Sensor Pt 100 Continuous Operation at 200 C flue gas temperature 450 C Ordering Information Catalog No. Length 1000 mm Length 1500 mm Length 2000 mm Dimensional Drawing (dimensions in mm) and Terminal Diagram /1500/2000 mm 25 x 1,5 40 x 2 Heater Pt Temperature Controller Connectionr 18 System Components for Sample Gas Sampling 10/ EN November 2004

19 Type 60 Probe Tube (Cement Flue Gas Probe) Use For sampling hot cement flue gas with high dust content for CO, CO 2, NO and SO 2 analysis in dry cement production process (e.g. recuperator furnaces, furnaces with grate coolers), at rotary kiln inlet and/or after precalcination. Process Gas Sampling Conditions Pressure p abs = max. 200 kpa (2 bar) Temperature max C for length = 3500 mm max C for length = 3000 mm max C for length = 2500 mm max C for length = 2000 mm max C for length = 1500 mm Flow Rate max. 250 l/h Dust Content max g/m 3 with periodical compressed air cleaning in conjunction with FE2 filter unit Dead Time (T t ) for Length = 3500 mm approx. 40 s at 60 l/h, approx. 9 s at 250 l/h 90% Time (T 90 ) for Length = 3500 mm approx. 82 s at 60 l/h, approx. 17 s at 250 l/h Pressure Drop approx. 10 hpa Materials of the Gas-carrying Parts Special steel, Material No Mounting A flanged probe connector (internal diameter 200 mm) should be installed by the customer. The mounting flange is essential for installing the probe tube. Cooling Water Supply Quality Drinking water quality with approx. 30 % anti-freeze if required Outlet Temperature min. 50 C (or > dew point of the cement flue gas), max. 85 C Pressure p abs = max. 400 kpa (4 bar) Quantity Circulated approx. 3 m 3 /h (closed system) Type 60 S Probe Tube Model with reinforced protection tube and flange DN 150, PN 16 Ordering Information Catalog No. Length 1500 mm Length 2000 mm Length 2500 mm Length 3000 mm Length 3500 mm Length 1500 mm, reinforced protection tube Length 2000 mm, reinforced protection tube Length 2500 mm, reinforced protection tube Length 3000 mm, reinforced protection tube Length 3500 mm, reinforced protection tube Type 60 S, length 1500 mm Type 60 S, length 2000 mm Type 60 S, length 2500 mm Type 60 S, length 3000 mm Type 60 S, length 3500 mm Dimensional Drawing (dimensions in mm) ø60,3 ø L3 L2 L1 ~ ~ A A 1 Sample gas inlet ports 2 Thickened shank of probe tube 3 Cooling water connections L1 Probe tube length L2 Length of thickened shank: 800 mm for L mm 1300 mm for L mm L3 200 mm with reinforced protection tube 10/ EN November 2004 System Components for Sample Gas Sampling 19

20 Probe 2 Use Wherever large volumes of gas are sampled, gas pressure is raised and there is a high moisture or dust content in the gas. Process Gas Sampling Conditions Pressure p abs = max. 400 kpa (4 bar) Temperature max. 450 C (probe tube unheated) max. 450 C (probe tube partially heated) max. 130 C (probe tube heated Flow Rate max l/h Dust Content max. 20 g/m 3 (application recommendation), max. 100 g/m 3 with purging Purging Pressure max. 600 kpa (6 bar) Heating Temperature of Inlet Filter 200 C (at process gas temperature of 20 C) 90% Time (T 90 ) < 2 s at 250 l/h Filter Fineness 0.3 µm Sample Gas Outlet G 1/4 internal thread DIN ISO 228/1 Test Gas/Purge Air Inlet G 3/8 internal thread DIN ISO 228/1 Electrical Connections Harting connector, IP 55 Probe Tube Heating Heat Output (unregulated) Nominal length 1200 mm: 650 W partially heated (for heating of the wall bushing): 255 W Nominal Voltage 230 V/115 V AC, 50 to 60 Hz Ordering Information Catalog No mm, 220 V, 650 W mm, 220 V, 255 W, partially heated Dimensional Drawing and Connection Diagram Z Material of the Gas-carrying Parts Support Tube, Heating Rod, Connecting Pipe Special steel, Material No Inlet Filter Aluminum oxide Seals Ceramic fiber Flange Special steel, Material No Mounting Flange DN 65, PN 6, Form B, to DIN 2573 position of holes: 45, 135, 225, 315 Mounting Angle any; 10 to 35 downwards from the horizontal recommended (take direction of flow into account), see dimensional diagram α = N 2 = L1 1 Filter mounting 2 Gas sampling probe tube 3 Sample gas outlet or test gas/purge air inlet 4 Harting connector Z System Components for Sample Gas Sampling 10/ EN November 2004

21 Probe 1, Probe 11 Probe 1 Use in interior air, garage and tunnel monitoring for the gases carbon monoxide (CO) and oxygen (SO 2 ) Probe 11 Use in interior air, garage and tunnel monitoring, including corrosive atmospheres. The materials used ensure that with the gases normally occurring no adsorption occurs. Technical Data Sampling Pressure Atmospheric pressure Gas Temperature 25 to +50 C Sample Gas Flow Rate max. 120 l/h Pressure Drop with New Filter 10 hpa at 120 l/h Dust Content in the Air approx. 100 mg/m 3 Sample Gas Connection Port G 1/8 internal thread DIN ISO 228/1 or nozzle for flexible tube of internal diameter 4 mm Materials Silicone carbide (filter), aluminum (end seals), PVC (nozzle) Transport and Storage Temperature 25 to +70 C Mounting On wall or suspended from ceiling Technical Data Sampling Pressure Atmospheric pressure Gas Temperature 25 to +50 C Sample Gas Flow Rate max. 70 l/h Pressure Drop with New Filter 10 hpa (mbar) at 70 l/h Service Life of Filter (estimated) filter constant (2500) d (days) = flow rate (l/h) x dust concentration (mg/m3 ) Sample Gas Connection Port Bolted connection for flexible pipe with internal diameter 4 mm and external diameter 7 mm Materials Polycarbonate (probe head), aluminum oxide (filter) Transport and Storage Temperature 25 to +70 C Mounting On wall or suspended from ceiling Ordering Information Catalog No. Room air probe Ordering Information Catalog No. Room air probe Dimensional Drawing (dimensions in mm) Dimensional Drawing (dimensions in mm) ~ 140 ~ 83 ~ mm wide 8,4 ~ 57 10/ EN November 2004 System Components for Sample Gas Sampling 21

22 Ceramic Filter Use For filtering dust from gases in the gas conditioning systems of analyzer systems when the gas sampling probe does not have a filter. The ceramic filter is positioned upstream the other devices in the sample gas conditioning chain. The ceramic filter can be heated with the annular heating element if condensation from the sample gas is likely. Technical Data Flow Rate (Air) max. 300 l/h Gas Pressure p abs = 20 kpa to 1.7 MPa (0.2 to 17 bar) at 20 C filter temperature, max. 200 kpa (2 bar) at 180 C Pressure Drop 0.1 to 0.85 hpa at 30 to 250 l/h (air) Dynamic Characteristics at Flow rate (air) 30 l/h 60 l/h 90 l/h Dead time T t 3.7 s 2.3 s 1.7 s 90% time T s 5.5 s 3.9 s Filter Fineness 0.5 µm Dimensional Drawing (dimensions in mm) Construction, Mounting Materials of the Gas-carrying Parts Housing: steel, St 37 K or special steel, Material No ; Filter: aluminum oxide; Seals: FPM, Cu, Al 2 O 3 fiber Gas Connection Ports G 1/4 internal thread DIN ISO 228/1 or pipe connectors for pipe of internal diameter 4 mm Filter Surface approx. 212 cm 2 Weight approx. 2.1 kg Filter Heating Annular heating element, see page 5 Mounting On wall with angle bracket Ordering Information Catalog No. Ceramic filter, steel version Ceramic filter, stainless steel version System Components for Sample Gas Sampling 10/ EN November 2004

23 Process Pressure Reducers Use If the pressure of the process gas is too high for the analyzer, a pressure reducer is required to lower the pressure. The type of pressure reducer used is determined by the properties of the process gas and the required sample gas pressure. Technical Data Construction Casing: Brass Casing: Brass Casing: Special steel Casing: Special steel Single-stage with one manometer (outlet) Single-stage with two Single-stage without manometers (inlet/ outlet) manometer Single-stage with two manometers (inlet/ outlet) Inlet pressure max. 1.5 MPa (15 bar) max. 3.5 MPa (35 bar) max. 3.5 MPa (35 bar) max. 3.5 MPa (35 bar) Outlet pressure (adjustable) Safety valve set to Manometer display Inlet pressure Manometer display Outlet pressure 0.8 to 10 kpa (8 to 100 mbar) 0 to 250 hpa (0 to 250 mbar) 10 to 40 kpa (0.1 to 0.4 bar) 50 kpa (0.5 bar) 0 to 4 MPa (0 to 40 bar) 0 to 60 kpa (0 to 0.6 bar) 10 to 70 kpa (0.1 to 0.7 bar) 80 kpa (0.8 bar) 10 to 70 kpa (0.1 to 0.7 bar) 80 kpa (0.8 bar) 0 to 4 MPa (0 to 40 bar) 0 to 150 kpa (0 to 1.5 bar) Flow rate 25 to 250 l/h 25 to 250 l/h 25 to 250 l/h 25 to 250 l/h Material Diaphragm Buna rubber Buna rubber Special steel Special steel Material Gasket Buna rubber Buna rubber EPDM EPDM Material Housing Brass Special steel; gascarrying parts: brass Special steel Special steel Weight approx kg approx kg approx kg approx kg Gas temperature and max. 50 C max. 50 C max. 50 C max. 50 C ambient temperature Catalog No Supplied: Pressure reducer with angle bracket 10/ EN November 2004 System Components for Sample Gas Sampling 23

24 Process Pressure Reducers Dimensional Drawings (dimensions in mm) Pressure reducer single-stage with one manometer (outlet) (Catalog No ) Pressure reducer single-stage without manometer (Catalog No ) 79 approx. 30 (variable) Ø 4 GasTech 105 approx. 94 (depending on handwheel position) Pressure reducer single-stage with two manometers (inlet/outlet) (Catalog No ) Pressure reducer single-stage with two manometers (inlet/outlet) (Catalog No ) 118 Ø4 approx. 30 (variable) 148 GasTech approx. 94 (depending on handwheel position) 24 System Components for Sample Gas Sampling 10/ EN November 2004

25 Heated Sample Gas Lines Heated Sample Gas Line CGWB 13 Parallel strip heater (holding temperature max. 200 C) Pt 100 resistance thermometer for control system Flexible sample gas pipe, replaceable (option) Self-regulating anti-frost heater (option) Self-regulating heater (option, holding temperature max. 100 C) Heated sample gas line TBL 01 Fixed resistor heating conductor (holding temperature max. 200 C) Pt 100 resistance thermometer for control system Self-regulating heater (option, holding temperature max. 100 C) Heated sample gas line TBL 01-E Competitive version Pipe ends with polyamide hard caps Selection Table for Heated Sample Gas Lines CGWB 13 TBL 01 TBL 01-E Heater Self-regulating strip heater (30 C) x Self-regulating strip heater (100 C) x x Fixed resistor heating conductor (200 C) x x Parallel strip heater x Outer covering Polyvinyl chloride Polyamide Polyamide Options Line can be shortened x Gas-carrying line can be replaced x Small bending radius x x Gas connections Various options Various options Stainless steel Electrical connections (heater and Pt 100) Power fixed, Pt 100 plug Power and Pt 100 plug Power and Pt 100 fixed Maximum line length 130 m (60 m) 100 m (40 m) 40 m Applications CO, O 2, CO 2 Anti-frost heater CO, O 2, CO 2 Holding temp. 100 C Holding temp. 100 C SO 2, NO x, C n H m Holding temp. 200 C Holding temp. 200 C Holding temp. 200 C 10/ EN November 2004 System Components for Sample Gas Sampling 25

26 CGWB 13 Heated Sample Gas Line Technical Data Frost protected line Self-regulating strip heater Regulated parallel strip heater Outer covering PVC PVC PVC Medium-carrying pipe PTFE PTFE PTFE Integral pipe-end connectors 1) POM cap POM cap Metal cap and metal cap with flange Heater self-regulating strip heater self-regulating strip heater CPD heating element, regulated Power supply 230 V or 115 V, 50 to 60 Hz 230 V or 115 V, 50 to 60 Hz 230 V or 115 V, 50 to 60 Hz Heat output 16 W/m 38 W/m 60 W/m Current consumption Making /holding current = 65/25 ma 0.15 A/m 0.3 A/m Holding temperature see diagram see diagram 200 C Ambient temperature T amb 30 to +60 C 30 to +60 C 30 to +60 C External diameter 30 mm 43 mm 40 mm; with replaceable flexible pipe: 45 mm Flexible sample gas pipe 6 x 4 x 1 mm or 8 x 6 x 1 mm 6 x 4 x 1 mm or 8 x 6 x 1 mm 6 x 4 x 1 mm or 8 x 6 x 1 mm Maximum line length 130 m 90 m 60 m with replaceable flexible pipe: 25 m, 60 m if laid straight Line duct PG 42 PG 42 PG 42 Minimum bending radius 300 mm 300 mm 300 mm Weight approx. 1 kg/m approx. 1 kg/m approx. 1 kg/m Connection lead for heater (fixed) 3 x 2.5 mm 2 ; length 2.5 m 3 x 2.5 mm 2 ; length 2.5 m 3 x 2.5 mm 2 ; length 2.5 m Connection lead for Pt 100 (with plug) 1) For line lengths > 10 m, only the analyzer side is assembled, an assembly set for the probe side is supplied. LIYCI 2 x 0.14 mm 2 ; length 5 m Holding Temperature Diagrams Frost protected line, 6 x 4 x 1 mm PTFE, 16 W/m, self-regulating Self-regulating strip heater, 6 x 4 x 1 mm PTFE Medium pipe temperature C Medium pipe temperature C Ambient temperature C Ambient temperature C Dimensional Drawing (dimensions in mm) L = m Probe Side Analyzer Side System Components for Sample Gas Sampling 10/ EN November 2004

27 CGWB 13 Heated Sample Gas Line Ordering Information Catalog No Version controlled (Pt 100) 2 self-regulated 16 W/m, 30 C (antifreeze) 3 self-regulated 38 W/m, 100 C 7 Connection probe side with metal cap for PFE 2 2 probe: metal cap / analyzer: flange 3 end of line: plastics 4 Gas conducting line PTFE-tube 6x4x1 mm 1 PTFE-tube 8x6x1 mm 2 Power supply 230 V, 50/60 Hz V, 50/60 Hz 2 Controlling and monitoring without Pt with 1 x Pt Catalog No / EN November 2004 System Components for Sample Gas Sampling 27

28 TBL 01, TBL 01-E Heated Sample Gas Lines Technical Data TBL 01 Self-regulating strip heater 30 W/m TBL 01 Fixed resistor heating conductor 90 W/m TBL 01-E Fixed resistor heating conductor 90 W/m Outer covering Polyamide corrugated tubing Polyamide corrugated tubing Polyamide corrugated tubing Medium-carrying pipe PTFE PTFE PTFE Integral pipe end connectors Hard caps, metal caps Hard caps, metal caps and metal cap with flange Polyamide hard caps Power supply 230 V or 115 V, 50 to 60 Hz 230 V or 115 V, 50 to 60 Hz 230 V or 115 V, 50 to 60 Hz Heat output 30 W/m 90 W/m 90 W/m Current consumption I = 0.15 A/m (starting current), I = f(length) I = f(length) I = 65 ma (holding current) Holding temperature see diagram on page C 200 C Ambient temperature 30 to +60 C 30 to +60 C 30 to +60 C External diameter 43 mm 43 mm 43 mm Flexible sample gas pipe 6 x 4 x 1 mm or 8 x 6 x 1 mm 6 x 4 x 1 mm or 8 x 6 x 1 mm 6 x 4 x 1 mm or 8 x 6 x 1 mm Flexible test gas pipe 6 x 4 x 1 mm Maximum line length 100 m 40 m 40 m Line duct PG 48 PG 48 Minimum bending radius 200 mm 200 mm 200 mm Weight approx. 1 kg/m approx. 1 kg/m approx. 1 kg/m Electrical connection for heater and Pt 100 Screw fitting (fixed for hard cap) Plugs (see dimensional drawing; fixed for hard cap) fixed TBL 01 Dimensional Drawing (dimensions in mm) Analyzer side Probe side A,B A PG11 B PG L = m TBL 01-E Dimensional Drawing (dimensions in mm) End Cap PA SS SS Sensor Location Length max. 40 m 28 System Components for Sample Gas Sampling 10/ EN November 2004

29 TBL 01, TBL 01-E Heated Sample Gas Lines TBL 01 Ordering Information Catalog No Design Resistor heating line 90 W/m 1 self regulating heating line 30 W/m 2 Gas conducting line with PTFE-tube 6x4x1 mm 1 with PTFE-tube 8x6x1 mm 3 Material of sheathing with plastic hose of PA (outside and indoors installation) 1 Connections End of line with flange connection 1 End of line: probe: metal cap / analyzer: flange 5 End of line with flanges 6 End of line with plastic tops 7 End of line with 2 metal tops 8 Control / Monitoring without Pt with 1 x Pt Power supply 230 V, Hz V, Hz 2 Catalog No TBL 01-E Ordering Information Catalog No. Resistor heating line 90 W/m, PTFE 6x4x1, PA caps, 230V Resistor heating line 90 W/m, PTFE 8x6x1, PA caps, 230V Resistor heating line 90 W/m, PTFE 6x4x1, PA caps, 115V Resistor heating line 90 W/m, PTFE 8x6x1, PA caps, 115V / EN November 2004 System Components for Sample Gas Sampling 29

30 Electronic Temperature Controller and Switching Relay Temperature Controller Control Range 200 to +850 C Measurement Input Pt 100 Outputs 2 x Relay 3 A, 250 V AC Power Supply 110 to 240 V AC +10/ 15 %, 48 to 63 Hz Dimensions 48 x 48 mm, C-rail housing Weight 140 g Catalog No Connection Diagram Switching Relay Load Voltage U rms = 24 to 265 V Max. Load Current I rms = 30 A (Ambient temperature = 25 C) Weight 200 g Catalog No System Components for Sample Gas Sampling 10/ EN November 2004

31

32 The Industrial IT word mark and all mentioned product names in the form XXXXX IT are registered or pending trademarks of ABB. ABB has Sales & Customer Support expertise in over 100 countries worldwide. The Company s policy is one of continuous product improvement and the right is reserved to modify the information contained herein without notice. Printed in the Fed. Rep. of Germany (10.04) ABB / EN Rev. 4 ABB Automation Products GmbH Analytical Division Stierstaedter Strasse Frankfurt am Main Germany Phone: Fax: analytical-mkt.deapr@de.abb.com

System components for sample gas sampling

System components for sample gas sampling Data Sheet 10/23-5.10 EN Rev. 9 System components for sample gas sampling Modular sample gas probe system FE2 Filter unit Annular heating element Heating sleeve PFE2 Filter unit PFE3 Filter unit Type 40,

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET. System components for sample gas sampling

ABB MEASUREMENT & ANALYTICS DATA SHEET. System components for sample gas sampling ABB MEASUREMENT & ANALYTICS DATA SHEET System components for sample gas sampling 2 SYSTEM COMPONENTS FOR SAMPLE GAS SAMPLING DS/SCS-EN REV. A Measurement made easy System components for sample gas sampling

More information

Modular Sample Gas Extraction System Probe Tubes Type 40, Type 42 Filter Units FE2, PFE2, PFE3. Operator s Manual 42/23-39 EN Rev.

Modular Sample Gas Extraction System Probe Tubes Type 40, Type 42 Filter Units FE2, PFE2, PFE3. Operator s Manual 42/23-39 EN Rev. Modular Sample Gas Extraction System Probe Tubes Type 40, Type 42 Filter Units FE2, PFE2, PFE3 Operator s Manual 42/23-39 EN Rev. 5 i Contents Preamble 3 Specified Use 4 Safety Information 5 Guide for

More information

System Components and Accessories for Sample Gas Conditioning. Data Sheet 10/ EN January 2004

System Components and Accessories for Sample Gas Conditioning. Data Sheet 10/ EN January 2004 System Components and Accessories for Sample Gas Conditioning Data Sheet 10/23-5.20 EN January 2004 A gas analysis system usually consists of two groups of devices: The gas analyzer measures the concentrations

More information

Zirconia Oxygen Probe

Zirconia Oxygen Probe Data Sheet SS/ZFG Issue Zirconia Oxygen Probe ZFG Series Environmental Certification MCERTS SIRA Certificate MC99000 Combustion monitoring control true wet measurement of net excess oxygen in situ measurement

More information

T 3965 EN Type 3965 Solenoid Valve Island To control pneumatic actuators

T 3965 EN Type 3965 Solenoid Valve Island To control pneumatic actuators T 365 EN Type 365 Solenoid Valve Island To control pneumatic actuators Application The Type 365 Solenoid Valve Island is a compact solution for the central control of pneumatic actuators in chemical and

More information

System Components and Accessories for Sample Gas Conditioning. Data Sheet 10/ EN December 2007

System Components and Accessories for Sample Gas Conditioning. Data Sheet 10/ EN December 2007 System Components and Accessories for Sample Gas Conditioning Data Sheet 0/3-5.0 EN December 007 Vol.% A gas analysis system usually consists of two groups of devices: The gas analyzer measures the concentrations

More information

Analyze IT Continuous Gas Analyzers Sample Conditioning SCC-K NO 2 /NO Converter. Operator s Manual 42/23-52 EN Rev. 1

Analyze IT Continuous Gas Analyzers Sample Conditioning SCC-K NO 2 /NO Converter. Operator s Manual 42/23-52 EN Rev. 1 Analyze IT Continuous Gas Analyzers Sample Conditioning SCC-K NO 2 /NO Converter Operator s Manual 42/23-52 EN Rev. 1 Table of Contents Page Preface 3 General Safety Information 4 Safety Tips for Handling

More information

Series 240 Type 3351 Pneumatic On/off Valve

Series 240 Type 3351 Pneumatic On/off Valve Series 240 Type 3351 Pneumatic On/off Valve Application Shut-off valve with tight shut-off for liquids, gases and vapors according to DIN or ANSI standards Valve size DN 15 to 100 NPS ½ to 4 Pressure rating

More information

Industrial flue gas probes. Instruction manual

Industrial flue gas probes. Instruction manual Industrial flue gas probes Instruction manual 2 1 Contents 1 Contents 1 Contents... 3 2 Safety and the environment... 4 2.1. About this document... 4 2.2. Ensure safety... 4 2.3. Protecting the environment...

More information

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram Data Sheet 403025 Page 1/10 JUMO dtrans p20 Process pressure transmitter Brief description The JUMO dtrans p20 pressure transmitter with HART interface combines maximum precision with easy operation. It

More information

Mounting and Operating Instructions EB 5894 EN. Electric control valves with jet pump. Flanged version of valve with jet pump

Mounting and Operating Instructions EB 5894 EN. Electric control valves with jet pump. Flanged version of valve with jet pump Electric control valves with jet pump Type 3267/5824, Type 3267/5825, Type 3267/3374, Type 3267/3274 Pneumatic control valves with jet pump Type 3267-1, Type 3267-7 Flanged version of valve with jet pump

More information

Series 240 Pneumatic On-off Valve Type 3351

Series 240 Pneumatic On-off Valve Type 3351 Series 240 Pneumatic On-off Valve Type 3351 Application Control valve with a tight shutoff of liquids, gases and steam in accordance with DIN or ANSI standards Nominal sizes DN 15 to 100 NPS ½ to 4 Nominal

More information

Solenoid Valve Island Type 3965

Solenoid Valve Island Type 3965 Solenoid Valve Island Type 365 for the control of pneumatic actuators General The Type 365 Solenoid Valve Island is a compact solution for the centralized control of pneumatic actuators in chemical and

More information

Mounting and Operating Instructions EB 5868/5869 EN

Mounting and Operating Instructions EB 5868/5869 EN Electric Control Valves Types 3213/5857, 3213/5824, Types 3214/5824, 3214/3374, 3214/3274 with safety function: Types 3213/5825, 3214/5825, 3214/3374, 3214/3274 Pneumatic Control Valves Types 3213/2780-1,

More information

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator Application Control valves designed for mechanical and plant engineering. Suitable for liquids, gases and steam Nominal size

More information

System 6000 Electropneumatic Converter for Direct Current Signals i/p Converter Type 6126

System 6000 Electropneumatic Converter for Direct Current Signals i/p Converter Type 6126 System 6 Electropneumatic Converter for Direct Current Signals i/p Converter Type 66 Application Devices used to convert a direct current signal into a pneumatic signal for measurement and control. Especially

More information

3/2-way Solenoid Valve for pneumatics

3/2-way Solenoid Valve for pneumatics 656 3/-way Solenoid Valve for pneumatics Compact design Single and manifold mounting Low power consumption Rocker pilot in DC Type 656 can be combined with... Fast response times Type 506 Type 510/511

More information

Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil with pneumatic or electric actuator

Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil with pneumatic or electric actuator Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil with pneumatic or electric actuator DIN version Application Mixing or diverting valves for heat transfer applications using organic media

More information

Differential Pressure Switch QBM81-

Differential Pressure Switch QBM81- s 1 552 Differential Pressure Switch QBM81- for air and nonaggressive gases For ventilation and air conditioning plants To monitor air filters, air flow, fan belts To monitor pressure in clean rooms, kitchens

More information

2/2-way Quarter-Turn Ball Valve in stainless steel with pneumatic rotary actuator, DN 10-50

2/2-way Quarter-Turn Ball Valve in stainless steel with pneumatic rotary actuator, DN 10-50 2/2-way Quarter-Turn Ball Valve in stainless steel with pneumatic rotary actuator, 10-50 (2652) (2655) 2 or ball valve Pneumatic actuator Compact design Visual position indicator Types 2652/2655 can be

More information

SATRON VTe pressure transmitter

SATRON VTe pressure transmitter SATRON VTe pressure transmitter belongs to the series V-transmitters which will have both analog and smart properties. SATRON VTe is used for 0-4 kpa...0-00 MPa ranges. The transmitter communicates in

More information

Process Inline Filter Protective filter PLF2-9HF

Process Inline Filter Protective filter PLF2-9HF Process Inline Filter Protective filter PLF2-9HF Specifications Nominal size: DN 300 - DN 600 Q s max: 3000 m 3 /h p s max: 16 bar Filtration ratings: 1-90 µm 1. GENERAL Product description Protective

More information

General Specifications

General Specifications General Specifications Model DT450G Dust Monitor GENERAL Powder is used in many industries including ceramics,cement, chemicals, pharmaceutical and food. In their processes, powder is collected in order

More information

Differential Pressure Switch QBM81-

Differential Pressure Switch QBM81- s 1 552 Differential Pressure Switch QBM81- for air and nonaggressive gases For ventilation and air conditioning plants To monitor air filters, air flow, fan belts To monitor pressure in clean rooms, kitchens

More information

Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil with pneumatic or electric actuator

Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil with pneumatic or electric actuator Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil with pneumatic or electric actuator ANSI version Application Mixing or diverting valves for heat transfer applications using organic

More information

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23 Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23 ANSI version Application Pressure regulators for set points from 0.075 to 400 psi (5 mbar to 28 bar) Valves in NPS ½ to 4

More information

Process Multi-Rheo Filter PMRF

Process Multi-Rheo Filter PMRF Process Multi-Rheo Filter PMRF PMRF-1 PMRF-2 PMRF-3 PMRF-5 PMRF-6 PMRF-7 1. Technical Specifications 1.1 General The filter series PMRF (for duplex filters see PMRFD) Process Multi- Rheo Filter completes

More information

Level Limit Switch soliphant FTM 930/931/932/ Z

Level Limit Switch soliphant FTM 930/931/932/ Z Technical Infmation TI 042F/00/e Level Limit Switch soliphant FTM 930/931/932/ Z F Universal Application with Bulk Materials and Dust Ex Area Application The Soliphant has a wide range of safe applications

More information

Data Sheet T EN

Data Sheet T EN Data Sheet T 8015-1 EN Series 240 Types 3241 1 PSA, -7 PSA, -9 PSA Pneumatic Control Valves Type 3241 PSA Globe Valve Application Control valves for PSA plants (Pressure Swing Adsorption) Valve sizes DN

More information

SITRANS P measuring instruments for pressure

SITRANS P measuring instruments for pressure Overview Siemens AG 009 Supplementary electronics for 4-wire connection Design Dimensions (W x H x D) in mm (inch) Electrical connection 80 x 10 x 60 (3.15 x 4.7 x.36) Screw terminals (Pg 13.5 cable inlet)

More information

Differential Pressure Sensors

Differential Pressure Sensors 1 910 1910P01 Differential Pressure Sensors for air or nonaggressive gases QBM66... Pressure-linear characteristic with selectable pressure measuring range Operating voltage AC 24 V or DC 13.5...33 V Output

More information

Series V2001 Valves Type 3531 Globe Valve for Heat Transfer Oil with pneumatic or electric actuator

Series V2001 Valves Type 3531 Globe Valve for Heat Transfer Oil with pneumatic or electric actuator Series V2001 Valves Type 3531 Globe Valve for Heat Transfer Oil with pneumatic or electric actuator DIN version Application Control valves for heat transfer applications using organic media according to

More information

Process Inline Filter PLF1

Process Inline Filter PLF1 Process Inline Filter PLF1 10 bar 16 bar Specifications Nominal size: DN 50 DN 150 Q s max: 200 m 3 /h p s max: 16 bar Filtration ratings: 1 90 µm 1. GENERAL Product description Continuous separation of

More information

SITRANS P measuring instruments for pressure

SITRANS P measuring instruments for pressure Overview Application The pressure transmitter is designed for the special requirements of the food, pharmaceutical and biotechnology industries. The use of high-grade materials guarantees compliance with

More information

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Compact System NRGS 11-2 NRGS Original Installation Instructions English Compact System NRGS 11-2 NRGS 16-2 EN English Original Installation Instructions 810366-05 1 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 LV (Low Voltage) Directive

More information

Special valves. Series. Solenoids. IP65 (with connector) Zones 1, 21 II 2 G II 2 GD EEx me IP64. Aluminium. Operation. Page no. EEx me IP65.

Special valves. Series. Solenoids. IP65 (with connector) Zones 1, 21 II 2 G II 2 GD EEx me IP64. Aluminium. Operation. Page no. EEx me IP65. Special valves Operation Series Page no. Function 2/2 Body material Brass Aluminium Solenoids IP Protection class Explosion proof class IP65 (with connector) Zones 1, 21 II 2 G II 2 GD EEx me IP64 EEx

More information

NAF-Triball ball valve

NAF-Triball ball valve NAF-Triball ball valve DN 10-100 for max. 40bar Fk 25.622(12)GB 12.09 Primary characteristics NAF-Triball is a full bore ball valve designed for shut-off, on-off functions as well as control application

More information

Series 240 Type Gas and Type Gas Automatic Shut-off Valves for Gases (valve class D)

Series 240 Type Gas and Type Gas Automatic Shut-off Valves for Gases (valve class D) Series 240 Type 3241-1-Gas and Type 3241-7-Gas Automatic Shut-off Valves for Gases (valve class D) DIN-DVGW typetested acc. to DIN EN 161 (2013-04) Application Control valve for control systems subject

More information

3D SERIES. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page

3D SERIES. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page CONTENTS Page - SPECIFICATIONS 0 SELECTION CHART 1 TYPE KEY 3 PERFORMANCE CURVE SPECIFICATIONS 4 PERFORMANCE CURVE 32-125 5 PERFORMANCE CURVE 32-6 PERFORMANCE CURVE 32-0 7 PERFORMANCE CURVE 40-125 8 PERFORMANCE

More information

MARINE APPROVED CEMS GREEN EFFICIENCY ON BOARD

MARINE APPROVED CEMS GREEN EFFICIENCY ON BOARD S-Keeper 7 MARINE APPROVED CEMS GREEN EFFICIENCY ON BOARD S-Keeper 7 ARE YOU A SHIPOWNER OPERATING IN EMISSIONS CONTROL AREAS ECAs? IS INCREASING SHIP EFFICIENCY YOUR TARGET? ARE FUEL SAVINGS STILL AN

More information

Self-operated Pressure Regulators Type Universal Pressure Reducing Valve

Self-operated Pressure Regulators Type Universal Pressure Reducing Valve Self-operated Pressure Regulators Type 41-23 Universal Pressure Reducing Valve ANSI version Application Pressure regulators for set points from 0.75 to 400 psi (0.05 to 28 bar) Valves in NPS ½ to 4 (DN

More information

Series 240 Type and Type Pneumatic Control Valves Type 3244 Three-way Valve

Series 240 Type and Type Pneumatic Control Valves Type 3244 Three-way Valve Series 240 Type 3244-1 and Type 3244-7 Pneumatic Control Valves Type 3244 Three-way Valve DIN and ANSI versions Application Mixing or diverting valve for process engineering and industrial applications

More information

TEK-F LUX 1400A. Electromagnetic Flowmeter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys FLOW

TEK-F LUX 1400A. Electromagnetic Flowmeter.  Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys FLOW Technology Solutions TEK-F LUX 1400A Electromagnetic Flowmeter FLOW www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Electromagnetic flowmeters are also

More information

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION VQ400M SERIES PRODUCT HANDBOOK APPLICATION The VQ400M Series class A safety combination valves are used for control and regulation of gaseous fluids in gas power burners, atmospheric gas boilers, melting

More information

JUMO MIDAS Pressure transmitter

JUMO MIDAS Pressure transmitter Phone: +44 19 635533 Fax: +44 19 6356 Data Sheet 401001 Page 1/5 JUMO MIDAS Pressure transmitter Brief description Pressure transmitters are used for measuring the relative (gauge) pressure in liquids

More information

Series 250 Pneumatic Control Valve Type and Type High Pressure Valve Type 3252

Series 250 Pneumatic Control Valve Type and Type High Pressure Valve Type 3252 Series 250 Pneumatic Control Valve Type 3252-1 and Type 3252-7 High Pressure Valve Type 3252 Application Control valve used control small flow rates in process engineering Nominal size G 1 2 1 NPT 1 2

More information

Differential Pressure and Flow meters Accessories for the Media Series

Differential Pressure and Flow meters Accessories for the Media Series Differential Pressure and Flow meters Accessories for the Media Series 7 8 9 10 11 6 12 Media 5 Media 6 Media 05 1 5 2 4 Media 4 3 Selection and application These accessories upgrade the devices of the

More information

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve 3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for

More information

ANSI version. The valve closes when the differential pressure rises

ANSI version. The valve closes when the differential pressure rises Self-operated Regulators Series 42 Differential Pressure Regulator with Type 2424/Type 2428 Actuator and Type 2422 Valve Type 42-24 A Type 42-24 B Type 42-28 A Type 42-28 B ANSI version Application For

More information

Series 42 Self-operated Regulators. Type RS Check Valve (backflow protection)

Series 42 Self-operated Regulators. Type RS Check Valve (backflow protection) Series 42 Self-operated Regulators Type 42-10 RS Check Valve (backflow protection) Application Designed to protect nitrogen and compressed air networks against backflow from directly connected systems.

More information

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION VQ400M SERIES PRODUCT HANDBOOK APPLICATION The VQ400M Series class A safety combination valves are used for control and regulation of gaseous fluids in gas power burners, atmospheric gas boilers, melting

More information

INSERTION flow sensor for continuous flow measurement

INSERTION flow sensor for continuous flow measurement INSERTION flow sensor for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN)

More information

Diaphragm Valve, Plastic 2/2 way, motorized

Diaphragm Valve, Plastic 2/2 way, motorized Diaphragm Valve, Plastic / way, motorized Construction Maintenancefree electric actuator Maintenancefree toothed belt drive Reversible synchronous motor Manual override Optical position indicator Features

More information

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518 3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics Type 658 standard standard High flow-rate capacity Reduced power consumption Single or manifold mounting Standard-, EEx m and EEx i versions

More information

SIHI LPH-X - Liquid Ring Vacuum Pump Two Stage

SIHI LPH-X - Liquid Ring Vacuum Pump Two Stage - Liquid Ring Vacuum Pump Two Stage LPH 45008, LPH 45311, LPH 45316 Pressure Range: Suction Volume: 33 to 1013 mbar 55 to 258 m³/h CONSTRUCTION Sterling SIHI liquid ring vacuum pumps have a simple but

More information

JUMO dtrans p20 DELTA

JUMO dtrans p20 DELTA Data Sheet 403022 Page 1/9 JUMO dtrans p20 DELTA Differential pressure transmitter Brief description The JUMO dtrans p20 DELTA differential pressure transmitter with HART interface combines maximum precision

More information

Digital ph transmitter

Digital ph transmitter Digital ph transmitter Compact, remote versions for DN 15 to 200 Fully programmable ph transmitter functions for all kinds of ph-measurement tasks Large range of process connections with various fittings

More information

Differential pressure gauges with Bourdon tube

Differential pressure gauges with Bourdon tube Differential pressure gauges with Bourdon tube Nominal dia. and with movement of Brass or stainless steel measuring monitoring analysing Description These pressure gauges are suitable for measuring of

More information

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve Type 367 Solenoid Valve Application Solenoid valve for controlling pneumatic linear actuators with NAMUR rib according to IEC 60534 or pneumatic rotary actuators with NAMUR interface according to VDI/VDE

More information

Differential pressure switch for monitoring air pressure in HVAC systems.

Differential pressure switch for monitoring air pressure in HVAC systems. Document No. CAN55E-P5 November 4, QBM8- Differential Pressure Switch Description Features Application Product Numbers Ordering Differential pressure switch for monitoring air pressure in HVAC systems.

More information

Sample Probe Module. Application Guide

Sample Probe Module. Application Guide Sample Probe Module Application Guide A Swagelok Pre-Engineered Subsystem Pre-engineered subsystems available in weeks, not months. Field-tested design ensures optimum system performance. Wide range of

More information

Metal tube variable area flowmeter for gases, liquids and steam

Metal tube variable area flowmeter for gases, liquids and steam Metal tube variable area flowmeter for gases, liquids and steam Metallic or plastic tube with a robust construction Indication by means of magnetic coupling Scales calibrated in l/h, m 3 /h, kg/h, t/h,

More information

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases Easy installation Local indication by means of direct reading Low pressure drop Scales directly in l/h, m 3 /h, kg/h, l/min,

More information

Piston Metering Pump REKOS KR

Piston Metering Pump REKOS KR MB 08 02 / General Rekos pumps can be supplied as simplex piston metering pumps type KR and duplex piston metering pumps type ZKR. Advantages of piston metering pumps are: minor dependency on back pressure

More information

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics /-, 5/- 5/-way Solenoid Valves for process pneumatics Type 658 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 658/659 can be combined with... Stard-, EEx

More information

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet Magnetic-inductive flow meter EPS / UMF2 Technical data sheet high accuracy: 0.3 % of actual maintenance-free no pressure drop numerous lining materials numerous electrode materials low-cost grounding

More information

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics /2-, 5/2-5/-way Solenoid Valves for process pneumatics Type 658 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 658/659 can be combined with... Stard-, EEx

More information

3/2-way and 2 x 3/2-way Rocker Solenoid Valve for pneumatics

3/2-way and 2 x 3/2-way Rocker Solenoid Valve for pneumatics 65 /-way and x /-way Rocker Solenoid Valve for pneumatics Type 65 can be combined with... Compact design Single and manifold mounting Low power consumption Rocker pilot in DC Fast response times Space

More information

Online data sheet S710 E S700 EXTRACTIVE GAS ANALYZERS

Online data sheet S710 E S700 EXTRACTIVE GAS ANALYZERS Online data sheet S71 E 1217512 S7 S71 E 1217512 S7 A B C D E F C US Detailed technical data Technical specifications Description Ordering information Type Part no. S71 E 1217512 1217512 Other models and

More information

Series 240 Pneumatic Control Valves Type and Type Three-way Valve Type 3244

Series 240 Pneumatic Control Valves Type and Type Three-way Valve Type 3244 Series 240 Pneumatic Control Valves Type 3244-1 and Type 3244-7 Three-way Valve Type 3244 DIN and ANSI versions Applications Mixing or flow-diverting valves for use in process engineering and industrial

More information

FilterMax DF. Modular dust multi purpose collector. Models

FilterMax DF. Modular dust multi purpose collector. Models Technical leaflet 988009 10 1 Date 2009-10-26 FilterMax DF Modular dust multi purpose collector FilterMax DF is a efficient and compact solution to your dust and fume problems. FilterMax DF handles the

More information

Remote Process Actuation Control System AirLINE - Siemens ET 200S

Remote Process Actuation Control System AirLINE - Siemens ET 200S Remote Process Actuation Control System AirLINE - Siemens ET 200S Type 8644 can be combined with... Fully compatible with Siemens ET 200S Combination of Fieldbus, pilot valves and I/O modules High flexibility

More information

Liquid ring vacuum pumps with magnetic coupling

Liquid ring vacuum pumps with magnetic coupling Liquid ring vacuum pumps with magnetic coupling LPH 75320, LPH 75330, LPH 75340 Pressure range: Suction volume flow: 33 to 1013 mbar 485 to 1615 m³/h CONSTRUCTION TYPE Sterling SIHI liquid ring vacuum

More information

SIHI LPH-X - Liquid Ring Vacuum Pump Two Stage

SIHI LPH-X - Liquid Ring Vacuum Pump Two Stage - Liquid Ring Vacuum Pump Two Stage 45008, 45311, 45316 Pressure Range: Suction Volume: 33 to 1013 mbar 55 to 258 m³/h CONSTRUCTION Sterling SIHI liquid ring vacuum pumps have a simple but robust construction

More information

Solenoid Valves Type 3963

Solenoid Valves Type 3963 Mounting and Operating Instructions Solenoid Valves Type 3963 Fig. 1 General Assembly, commissioning and operation of these devices may only be performed by experienced personnel. Proper shipping and appropriate

More information

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate 1 919 1919P01 QBM65/C, QBM75-1U/C Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate Highly accurate measurements with calibration certificate Simple and quick

More information

FilterMax F. Modular dust collector with integrated pre-separator. Models

FilterMax F. Modular dust collector with integrated pre-separator. Models Technical leaflet 988010 10 1 Date 2009-11-02 FilterMax F Modular dust collector with integrated pre-separator FilterMax F is a complete filter solution for the entire workshop. With it s integrated preseparator

More information

ZMT & ZFG2 Zirconia Oxygen Analyzer Systems. Superior technology and quality from the world leader in oxygen measurement

ZMT & ZFG2 Zirconia Oxygen Analyzer Systems. Superior technology and quality from the world leader in oxygen measurement Data sheet DS/ZMT/LO EN Rev. J ZMT & ZFG Superior technology and quality from the world leader in oxygen measurement Integral reference-air supply option avoids necessity for additional equipment Dual

More information

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1 INLINE Flow sensor for hazardous area II G/D - II D - II GD - I M Type SE0 Ex can be combined with... Flow meter with NAMUR or NPN/PNP output signal Mounting, dismounting of electronics by a Quarter-Turn

More information

Remote Process Actuation Control System AirLINE - Rockwell 1734 Point I/O System

Remote Process Actuation Control System AirLINE - Rockwell 1734 Point I/O System Remote Process Actuation Control System AirLINE - Rockwell 1734 Type 8644 can be combined with... Fully compatible with Rockwell 1734 Point I/O System Combination of Fieldbus, pilot valves and I/O modules

More information

CBU144. Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717. Product specification sheet

CBU144. Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717. Product specification sheet CBU144 Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717 Product specification sheet Version The Compact Booster Unit consists of the following modules, that

More information

Differential Pressure Sensors

Differential Pressure Sensors 1 920 1920P01 Differential Pressure Sensors for neutral and mildly corrosive liquids and gases QBE63-DP Differential pressure sensor, suitable for gases and liquids, for the measurement of positive and

More information

TRIVAC NT 16 and NT 25

TRIVAC NT 16 and NT 25 TRIVAC NT 16 and NT 25 idealvac.com (505)872-0037 idealvac.com TRIVAC NT 16 Type DN a b b1 c h h1 h2 l m n o NT 16 1) mm 25 KF 32 175 137 135 243 227 261 540 280 140 132 in. 25 KF 1.26 6.89 5.39 5.31 9.57

More information

Solenoid Valve Type 3962

Solenoid Valve Type 3962 Solenoid Valve Type 362 x d, x em or without explosion protection, for controlling pneumatic actuators General The Type 362 Solenoid Valve ensures a high level of operational reliability for controlling

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET. System components for sample gas conditioning

ABB MEASUREMENT & ANALYTICS DATA SHEET. System components for sample gas conditioning ABB MEASUREMENT & ANALYTICS DATA SHEET System components for sample gas conditioning 2 SYSTEM COMPONENTS FOR SAMPLE GAS CONDITIONING DS/SCC-EN REV. A Measurement made easy System components for sample

More information

Control valves with pneumatic actuators up to 350 C PN

Control valves with pneumatic actuators up to 350 C PN 300 540 1080 2 Features Suitable in building and process engineering for various mediums 0...+200 C Suitable with stuffing box extension or stem seal with stainless steel bellow to 10...+350 C and for

More information

Automated Globe Valves. BOA-H Mat P PN 16/25 DN Type Series Booklet

Automated Globe Valves. BOA-H Mat P PN 16/25 DN Type Series Booklet Automated Globe Valves BOA-H Mat P PN 16/25 DN 20-150 Type Series Booklet Legal information/copyright Type Series Booklet BOA-H Mat P All rights reserved. The contents provided herein must neither be distributed,

More information

Vortex Flow Sensors VA Di also suitable for applications in condensation and particle laden gases. Drawing 1

Vortex Flow Sensors VA Di also suitable for applications in condensation and particle laden gases. Drawing 1 Vortex Flow Sensors VA Di Vortex Flow Sensors VA Di also suitable for applications in condensation and particle laden gases Drawing 1 Measurable variable actual flow rate standard velocity standard flow

More information

Pressure transmitter COMPACT ECOnomic

Pressure transmitter COMPACT ECOnomic Pressure transmitter COMPACT ECOnomic for food/pharmaceutical/biotechnology, Type series CA1110 Features Digitale pressure transmitter Hygienic design according to EHEDG Case and wetted parts of stainless

More information

Type and Type Pneumatic Control Valves Type 3510 Micro-flow Valve

Type and Type Pneumatic Control Valves Type 3510 Micro-flow Valve Type 3510-1 and Type 3510-7 Pneumatic Control Valves Type 3510 Micro-flow Valve ANSI version Application Control valve especially designed for controlling low flow rates in pilot plants and technical research

More information

Side channel pumps PN 16 SOH - SOHB. Self-priming centrifugal pumps. Technical description

Side channel pumps PN 16 SOH - SOHB. Self-priming centrifugal pumps. Technical description Side channel pumps PN 16 Self-priming centrifugal pumps SOH - SOHB Technical description Operating data Design Industries Media pumped: Nominal diameter: 1-1 1 /2 Flow rate: 0.3-7.5 m 3 /h Pump head: 5-155

More information

Differential pressure sensor

Differential pressure sensor s 1 916 QBM3x20-.. QBM3x20-..D Differential pressure sensor for air and non-aggressive gases QBM3020-.. QBM3120-.. High degree of measuring accuracy Adjustable characteristic curve (pressure-linear or

More information

ETP80. Electronic Transmitter for Pressure, Differential Pressure and Level

ETP80. Electronic Transmitter for Pressure, Differential Pressure and Level ETP80 Electronic Transmitter for Pressure, Differential Pressure and Level The ETP80 is a series of pressure transmitters with a wide range of s to suit most applications. The transmitters can measure

More information

Typetested for liquid fuels and liquefied petroleum gas (LPG) in the liquid phase (see Data Sheet T 8022 EN) Version according to ANSI standards

Typetested for liquid fuels and liquefied petroleum gas (LPG) in the liquid phase (see Data Sheet T 8022 EN) Version according to ANSI standards Series 240 Pneumatic Control and Quick-acting Shut-off Valves for gases Type 3241-1-Gas and Type 3241-7-Gas DIN-DVGW typetested acc. DIN EN 161 (1996-08) Application Control valves for control equipment

More information

Digital ph transmitter

Digital ph transmitter Digital ph transmitter Compact, remote versions for DN 15 to 200 Fully programmable ph transmitter functions for all kinds of ph-measurement tasks Large range of process connections with various fittings

More information

TEMPERATURE CONTROL AND MONITORING HYDRAULIC COMPONENTS

TEMPERATURE CONTROL AND MONITORING HYDRAULIC COMPONENTS Electronic level and temperature control Gasket (NBR) Operating pressure: max. 1 bar Operating temperature: -20 C up to +80 C Ambient temperature: -20 C up to +70 C Weight: approx. 400g Sealing fl uid:

More information

FilterMax DF. Modular dust multi purpose collector. Models

FilterMax DF. Modular dust multi purpose collector. Models Modular dust multi purpose collector FilterMax DF is a efficient and compact solution to your dust and fume problems. FilterMax DF handles the air polution from metal industries as well as non explosive

More information

2600T Series Pressure Transmitter

2600T Series Pressure Transmitter Data Sheet 2600T Series Pressure Transmitter Model 261GS Gauge Model 261AS Absolute standard overload Base accuracy: ±0.15 % Span limits 0.3 to 60000kPa; 1.2inH 2 O to 8700psi 0.3 to 3000kPa abs; 2.25mmHg

More information

3D SERIES. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page

3D SERIES. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page CONTENTS Page SPECIFICATIONS 0 SELECTION CHART 1 TYPE KEY 3 PERFORMANCE CURVE SPECIFICATIONS 4 MEI INDEX SPECIFICATIONS 5 PERFORMANCE CURVE 32 6 PERFORMANCE CURVE 32 7 PERFORMANCE CURVE 320 8 PERFORMANCE