1

2 Neo-Dyn Our Key to Success and Commitment eople Are the Key to Our Success Neo-Dyn s founders had more than 200 years cumulative experience in the design and manufacture of pressure switches when they started the company in Over the years, we have built a substantial work force of skilled professionals in every discipline, from design and testing, to marketing and manufacturing. Many of our people have been with the company since its beginning. In-House Capabilities for Total Control Having total in-house capabilities, we provide our customers with high quality products with rapid delivery and competitive prices. Broad Range Capabilities Although our standard product line is among the broadest in the industry, we are not limited to what is seen in our catalog. Long before we developed our standard product line, we had a reputation for manufacturing the highest quality specialty switches available. If you don t see what you want in our catalog, our application and engineering staff will work with you to provide a switch, ideally suited to your application. Total Reliability In addition to our commercial and industrial products, we supply switches to the military and aerospace industries. What this means to our customers is the highest quality control standards in the industry. Commitment to Research and Development As an industry leader, Neo-Dyn is on the cutting edge of technology, developing new products, manufacturing methods, and materials to meet our customers present and future needs. Neo-Dyn Industry Drive Valencia, CA tel: fax: Form #087-11/14

3 Neo-Dyn Repeatability, Accuracy and Maintenance for ressure Switches REEATABILITY Repeatability is the maximum set point deviation of a single pressure switch under one given set of environmental and operational conditions. Since adjustable pressure switches can be set at any discrete set point within its given adjustable range this is the most common performance criteria stated by the manufacturer. A general repeatability statement is that a ITT Neo-Dyn pressure switch will repeat within ± 0.5% of its set point when set in the upper 80% of its adjustable range for set points above 10 psig. Exceptions to this statement could include piston sensor pressure switches and switches whose adjustable range is inches of water. ACCURACY Accuracy is a term generally associated with analog instruments such as transducers and transmitters. Since a pressure switch is meant to give a contact opening or closure at a discrete set point an accuracy statement can only be given if all operational and environmental conditions are clearly defined. For example, what is the accuracy of an Neo-Dyn model 10012C3 when set at 150 psig increasing pressure when cycled between 150 psig and 130 psig for 500 cycles over a temperature range of +40 to +160 degrees Fahrenheit at a cycle rate of 15 cycles per minute. Again, the model, the operational and environmental conditions must all be defined. ITT Neo-Dyn can provide limited testing on some of its models under various test conditions. MAINTENANCE Under normal circumstances ITT Neo-Dyn pressure switches do not require maintenance or re-calibration. For critical applications or those where the switches are used in a severe environment, it is suggested a calibration check be performed at intervals based upon actual in service stability data. For more information, please visit rinted in U.S.A.

4 Neo-Dyn Temperature Limitations for ressure Switches ressure switch applications often have media temperatures that are in excess of our published specifications. Even though most of Neo-Dyn s switches can actually withstand temperatures higher than those listed, they are published for varying reasons that include effects on; set point shift, decreased life expectancy, or in some cases, damage. O-rings themselves have limitations even though they are capable of temperatures higher than those we publish for the switches. Generally speaking, Buna-N and ER are good up to 250 F (121ºC), Viton up to 400 F (204ºC). The welded assemblies have no o-rings at all. The main purpose of this bulletin is to advise the end user that the media temperature limitations of these switches can be overcome by simply increasing the distance of the switch from the source of the media. Since Neo-Dyn s pressure switches are dead-ended devices, the temperature at the diaphragm or piston will not be the same as it is at the media. Often a 1 ft. (30.46 cm) length of uninsulated 1/4 inch, SS tubing is enough to lower the temperature to within published specifications. The rule of thumb utilized for these applications is as follows: For every 2 ft. (60.96 centimeters) of uninsulated-1/4 inch-ss tubing, you dissipate 100 ºF (37.77 ºC), in excess of +200 ºF (+93.3 ºC). It will of course depend on the initial media temperature, type of media, ambient temperature, and piping size & material. In some cases a longer capillary may be the best solution. Typically the tubing is coiled, so as to conserve space (pig tail). There are also other methods for dissipating heat, such as condensate chambers or reservoirs filled with liquid, which will act in the same manner as a diaphragm seal in isolating and dissipating the heat. These methods are better explained in ISA, ASME or other such industry and engineering standard practice texts. Should you have further questions or require additional information, please contact your Regional Sales Manager or the factory directly. For more information, please visit

5 Neo-Dyn Quick Reference Charts Adjustable ressure Switches ADJUSTABLE RESSURE RANGE 0 to 40 H H 2 0 to 15 psig 2.3 to 2800 psig 14 to psig WETTED MATERIAL ENCLOSURE ORT DIAHRAGM NeMA 3, 4, 13 NeMA 7, 9 ALUM. stain. HAsTeLLo y Mo NeL o Ly MIDe BUNA N stain. TANTLM. ELECTRICAL FORM HAsTeLLo y sdt DDT SERIES Do UBLe BRAKe /101* 200/201* * Applicable to Nema 3, 4 and 13 enclosure only Compact Adjustable ressure Switches ADJUSTABLE RESSURE RANGE 1 to 170 psig 1 to 2300 psig 1 to 2300 psig 25 to 6000 psig 1 to 200 psig NeMA 3, 4, 13 WETTED MATERIAL ENCLOSURE ORT DIAHRAGM NeMA 7, 9 ALUMINUM stainless o Ly IMIDe stainless ELECTRICAL FORM sdt DDT SERIES Adjustable ressure Switches for Chemical rocessing Industry ADJUSTABLE RESSURE RANGE 1.5 to 325 psig 1 to 2300 psig WETTED MATERIAL ENCLOSURE ORT DIAHRAGM NeMA 3, 4, 13 NeMA 7, 9 steel stain. HAsTeLLo y Mo NeL o Ly MIDe s TAIN. TANTLM. HAsTeLLo y o NeL ELECTRICAL FORM sdt DDT SERIES Adjustable Vacuum Switches ADJUSTABLE VACUUM RANGE 0 to 40 H to 28 Hg 2 to 28 Hg WETTED MATERIAL ENCLOSURE ORT DIAHRAGM NeMA 3, 4, 13 NeMA 7, 9 ALUMINUM s TAINLes s HAsTeLLo y o Ly MIDe BUNA N stain. TANTLM. HAsTeLLo y ELECTRICAL FORM DDT Do UBLe BRAKe sdt SERIES

6 Quick Reference Charts - continue Adjustable Differential ressure Switches ADJUSTABLE RESSURE RANGE NeMA 3, 4, 13.5 to 100" H 2 0 Diff. 1 to 150" H to 60 psid 1 to 200 psid WETTED MATERIAL ENCLOSURE ORT DIAHRAGM NeMA 7, 9 ALUMINUM stainless OLY IMIDE stainless TANTALUM HASTELLOY ELECTRICAL FORM sdt DDT Do UBLe BRAKe SERIES Adjustable Temperature Switches ADJUSTABLE TEMERATURE RANGE -69 to +500 F -69 to +925 F -69 to +395 F -69 to +655 F NeMA 3, 4, 13 ENCLOSURE NeMA 7, 9 steel & stainless WETTED MATERIALS stainless BRAss/sTAINLess ELECTRICAL FORM sdt DDT Do UBLe BRAKe SERIES 100T 100TC 132T 132TC Factory Set/Tamperproof ressure Switches FIXED SET-OINT RANGE 1.5 to 250 psig 2 to 2000 psig 20 to 3050 psig 15 to 7500 psig NeMA 1&2 WETTED MATERIAL ENCLOSURE ORT DIAHRAGM NeMA 3, 4, 13 NeMA 7, 9 ALUMINUM stainless o Ly IMIDe stainless ELECTRICAL FORM sdt DDT SERIES 115/ / harmaceutical/biochem ADJUSTABLE SET-OINT RANGE 1 to 725 psig ENCLOSURE ORT WETTED MATERIAL DIAHRAGM NeMA 1&2 NeMA 3, 4, 13 NeMA 7, 9 ALUMINUM stainless o Ly IMIDe stainless ELECTRICAL FORM sdt DDT SERIES 117 Neo-Dyn Industry Drive Valencia, CA tel: fax: AER0935_56 11/14

7 Neo-Dyn Conventional ressure Switch Design Constant Rate Spring A constant rate type pressure switch, i.e., a bellows, diaphragm, bourdon tube and spring loaded piston, are linear devices for a certain pressure change the pressure element moves a given distance. For additional movement more pressure (force) is applied. The position of the electrical switch, therefore, influences and/or dictates the pressure switch set point. DIAHRAGM SRING LOADED ISTON BELLOWS BOURDON TUBE Disadvantages of the Constant Rate Switches NON-STABLE SET OINTS - Requires Constant Recalibration BECAUSE: Sensor mechanism follows the system pressure subject to fatigue. Set point influenced by snap acting electrical variations in snap switch differential affects deadband of pressure switch. Ambient temperature sensitive relocation of electrical switch causes change in set points. Linkage used to adjust electrical switch linkage wear relocates electrical, causing set point change. VIBRATION SENSITIVE - Causes Contact Chatter BECAUSE: Constant rate device mimics dynamic input intermittent electrical signal if vibration occurs when switch is near actuation. Larger mass associated with constant rate sensor mechanisms more mass means less vibration resistance. Spring mounted electricals or linkages resonance frequency can cause spring or linkage to take off causing electrical contacts to chatter. OVER-RESSURE SENSITIVE - Affects Set oint Accuracy BECAUSE: Motion transfer device must contain pressure bellows, bourdon tubes, and welded diaphragms contain pressure as well as actuate the electrical. Limited sensor support sensors with limited overpressure support are subject to set point drift. LIMITED CYCLE LIFE - Dependent on Set oint BECAUSE: Longer stroke repositioning the electrical for set point changes requires greater movement. Shorter electrical life sneaking up on the electrical can cause an electrical arc.

8 Neo-Dyn ressure Switch Design Nega-Rate Belleville Spring A negative rate type pressure switch (i.e., a Belleville spring) is a snap acting device. At a certain pressure (apex of the spring curve) the spring snaps over center. At this point, it takes less pressure (force) to continue its movement. The pressure switch set point is a function of the Belleville spring. The electrical switch is in a fixed position and is synchronized to the movement of the Belleville. DEACTUATED Advantages of the Nega-Rate Belleville Disc Spring Switches STABLE SET OINTS - Eliminates Constant Recalibration BECAUSE: No moving parts except during actuation no spring fatigue or wear. Set point is mostly a function of the negative rate Belleville spring variables in snap action electrical have little effect on the set point. Total movement of the Belleville spring compensates for any relocation of the electrical due to case growth consistent set point over temperature change. No linkage utilized no wear which can affect accuracy. VIBRATION RESISTANT - Eliminates Contact Chatter BECAUSE: Belleville spring does not preload the electrical prior to actuation snap action electrical maintains its vibration resistant characteristic. Small mass and inherent stability of the Belleville spring resists chatter caused by vibration. Snap action electrical is ruggedly mounted with minimal bracketry no spring mounted electricals or linkages. HIGH OVER-RESSURE CAABILITY - No Affect on Set oint Accuracy BECAUSE: Belleville spring does not contain the pressure no affect on system or proof pressure capability. The pressure sensing portion bottoms out after actuation and is fully supported pressure sensing parts are designed for high pressure conditions. Limited movement of spring mechanism no overtravel of the snap action electrical due to high pressure. HIGH CYCLE LIFE - Millions of Cycles BECAUSE: Short stroke minimizes wear Belleville spring mechanism is exercised less than.020". Snap action of Belleville spring reduces electrical arc prolongs contact life. ACTUATED Neo-Dyn Industry Drive Valencia, CA tel: fax: Form #089 11/14

9 Neo-Dyn Neo-Dyn ressure, Flow & Temperature Switch Definitions & Terminology Introduction The following definitions and terminology describe the operating characteristics, specifications and other details relative to pressure, flow, and temperature switches. Types of Switches ABSOLUTE RESSURE SWITCH: A switch that compares the pressure being sensed to that of a perfect vacuum. Construction requires the reference chamber to be evacuated. DIFFERENTIAL RESSURE SWITCH: A switch having both a high and low pressure port. Actuation occurs when pressure to the high port exceeds pressure to the low port by a predetermined value. FLOW SWITCH: A Neo-Dyn flow switch senses differential pressure generated by flow through a venturi to actuate an electrical switch at a predetermined flow level. Definitions Absolute ressure - The difference between zero pressure (which exists only in a perfect vacuum) and some known pressure. Absolute pressure may be determined by adding gauge pressure to atmospheric pressure (14.7 psi at sea level). Actuation oint - The point at which electrical switching element is operated on increasing or decreasing pressure. Neo-Dyn considers this point the increasing set point. Ambient ressure (or Temperature) - ressure (or temp-erature) immediately surrounding the switch. Atmospheric ressure - The pressure caused by the weight of air. Atmospheric pressure at sea level is considered to be 14.7 psia (or 29.9 inches of mercury or 407 inches of water absolute.) Burst ressure - Burst pressure is the maximum pressure which may be applied to a switch without causing leakage. ermanent degradation may occur or the unit may become Inoperable if burst pressure is applied. Burst pressure is normally 2Z x to 3 times maximum system pressure. Charge Media - The fluid or gas with which the temperature sensing probe is filled. Critical Set oint - The critical set point is the most important set point of the unit and is held to the closest tolerance. It can be either the actuation (increasing) or deactuation (decreasing) set point. Deactuation oint - The point at which the electrical switching element is operated on increasing or decreasing pressure. Neo-Dyn considers this point the decreasing set point. We hope this data provides the answers to questions which may arise and helps you in selecting a switch. GAUGE RESSURE (AND VACUUM) SWITCH: A switch that compares the pressure being sensed to that of atmospheric pressure. ositive pressure switches sense monitored pressure above atmospheric pressure while vacuum switches sense pressure below atmospheric. TEMERATURE SWITCH: A Neo-Dyn temperature switch is identical to a pressure switch with the addition of a fluid-vapor charged sensing probe. The fluid-vapor charge is exposed to the basic sensor and since probe pressure varies with temperature, discrete temperature settings can be accomplished. Deadband - The deadband, sometimes referred to as differential value, is the change in value between actuation and deactuation set points. Differential ressure - The difference between the two pressures being measured. Direct Mount - A phrase used to refer to the mounting of an instrument directly at the source of the process variable (pressure or temperature) being sensed. - Industry standards have established letter designations for the various electrical arrangements. They are C for SDT, CC for DDT and Z for double break. Form C : Single ole Double Throw (SDT) Switching Element - An SDT switching element has one normally closed, one normally open, and one common terminal. Three terminals mean that the element can be wired with the circuit either normally open (N/0) or normally closed (N/C). Form CC : Double ole Double Throw (DDT) Switching Element - A DDT switching element has six electrical terminals, two normally closed, two normally open and two common. Neo-Dyn uses two independent SDT switching elements. Some units are designed for simultaneous operation whereas, others are for separate operation at different set points. Form Z : Double Break Switching Element - A double break switching has two isolated circuits. Four terminals facilitate wiring one circuit normally open and the other normally closed.

10 Neo-Dyn ressure, Flow & Temperature Switch Definitions & Terminology Electrical Switching Element - The electrical switching element opens or closes an electrical circuit in response to movement by the pressure/temperature sensor. Most Neo-Dyn products are available in SST, SDT and DDT. Non-Critical Set oint - The non-critical set point is the least important setting and the tolerances are not held as close as the critical set point. It can be either the actuation or deactuation point. (Housing) - That part of the instrument which, in varying degrees, protects the mechanism from ambient conditions. Explosion roof - An enclosure which is capable of withstanding an explosion which may occur within, and capable of preventing the ignition of an explosive atmosphere which may surround it. Gauge ressure - Gauge pressure is the difference between atmospheric pressure and a variable pressure. Hermetically Sealed - An enclosure completely sealed from the environment. Neo-Dyn hermetically sealed electrical assemblies are all metal with a glass header. All joints are soldered or welded to insure sealing integrity. Mass Rate of Flow - An expression of flow by weight in a given time, such as pounds per hour (H). Media - The liquid or gas being sensed by the instrument. NEMA Classifications Ref: NEMA Standards ublication, ub. No. ICS NEMA Type 1 - General urpose - Indoor Type 2 - Dripproof - Indoor Type 3 - Dusttight, Raintight and Sleet (Ice) Resistant - Outdoor Type 3R - Rainproof and Sleet (Ice) Resistant - Outdoor Type 3S - Dusttight, Raintight and Sleet (Ice) roof - Outdoor Type 4 - Watertight and Dusttight - Indoor and Outdoor Type 4X - Watertight, Dusttight and Corrosion Resistant - Indoor and Outdoor Type 5 - Superseded by Type 12 for Control Apparatus Type 6 - Submersible, Watertight, Dusttight and Sleet Resistant - Indoor and Outdoor Type 7 - Class I, Group A, B, C or D Hazardous Locations; Airbreak Equipment - Indoor Type 8 - Class I, Group A, B, C or D Hazardous Locations; Oil-Immersed Equipment - Indoor Type 9 - Class II, Group E, F or G Hazardous Locations; Airbreak Equipment - Indoor Type 10 - Bureau of Mines Type 11 - Corrosion Resistant and Dripproof; Oil-Immersed - Indoor Type 12 - Industrial Use, Dusttight and Driptight - Indoor Type 13 - Oiltight and Dusttight - Indoor olyimide - An engineering thermoplastic polymer characterized by high tensile strength, excellent wear resistance, chemical and radiation inertness, and good dielectric properties over a wide temperature range. Neo-Dyn uses Duont Kapton Type F teflon coated flexible polyimide film as a diaphragm material. Note: Although excellent for most applications, polyimide is subject to cracking after prolonged exposure to water above 140 F. ressure - Force per unit of area. ressure Sensing Element - The pressure sensing element is that component part which moves as pressure increases or decreases, operating an electrical switching element at a predetermined point. Neo-Dyn Nega-Rate pressure switches utilize a diaphragm or piston as a media seal with a Belleville negative-rate disc spring system. ressure Switch - A pressure switch is an instrument designed to convert pressure into motion to operate an electrical switching element thereby making or breaking an electrical circuit. roof ressure (or Temperature) - Normally 1Z\x to 2 times system, it is the maximum momentary pressure (or temperature) including surges, which may be applied to any switch without causing permanent degradation. Remote Mount - A phrase used to refer to the mounting of an instrument away from the source of the process variable being sensed (usually via a capillary tube). Repeatability - Repeatability is the maximum set point deviation of a single pressure switch under one given set of environmental and operational conditions. Special Switch - A unit which is modified outside the limits of a standard catalog item. System (Working) ressure - System pressure is the operating pressure of any hydraulic or pneumatic system. Tolerance - Tolerance is the maximum allowable setting deviation between two or more production units under all specified environmental and operational conditions. Tolerance represents the sum total of setting deviations due to calibration and manufacturing variations, temperature changes, etc. Variable ressure - Changing pressure, generally the pressure which is being measured or controlled. Volume Rate of Flow - An expression of flow by volume in a given time, such as gallons per minute (GM). s - That portion of the unit which comes in contact with the pressure media. Neo-Dyn Industry Drive Valencia, CA tel: Form #090-11/14

11 Neo-Dyn Media Compatibility Information The following is a chart of common media with recommended O-Ring compounds that can be used with the olyimide and Elastomer diaphragms used in Neo-Dyn pressure switches except as noted. NOTE: The information given on this chart is typical performance data for Kapton Type H and Type F films; it is not intended to be used as design data. We believe this Information is the best currently available on the subject. It is offered as a possible helpful suggestion in experimentation you may care to undertake along these lines. It is subject to revision as additional knowledge and experience are gained. Neo-Dyn makes no guarantee of results and assumes no obligation or liability whatsoever in connection with this information. O-Ring Compound BUNA-N ER VITON KALREZ Acetic Acid Acetone Acetylene Air Ammonia, Anhydrous * Asphalt Beer Benzene Black Liquor Boric Acid Brake Fluid Brayco 719-R Brayco 885 Bunker Oil Butane Carbon Dioxide Carbon Monoxide Cellulube A60, 90, 100, 150, 220, 300 and 500 Chlorine Chlorobenzene * Citric Acid Coke Oven Gas Coolanol Diesel Di-ester-Lubricant, Mil-L-7808 Dowtherm A and E Ethanol Ethylene Ethylene Glycol Freon 11, 12, 112 and 114 Freon 21 Freon 22 * Fyrquel Fuel Oil Gasoline Helium Houghto Safe 271, 620, 1010, 1055 and 1120 Houghto Safe 5040 Hydraulic Oil (etroleum Base) Hydrocarbons Hydrochloric Acid * Hydrofluoric Acid * O-Ring Compound BUNA-N ER VITON KALREZ Hydrogen Hydrogen Sulphide Isopropanol J-3, 4, 5 and 6 Kerosene Linseed Oils Liquid etroleum Gas Lubricating Oils (etroleum Base) Mercury * Methanol Methyl Ethyl Ketone (MEK) Mineral Oils Naptha Natural Gas Nitric Acid Nitrogen Oleum Spirits Oxygen Ozone etroleum Oil, Crude hosphoric Acid ropane ropanol ropylene ydraul 135, 150, A200, 312, AC, F-9 and 625 Shell Iris 902 Silicone Greases Silicone Oils Skydrol 500 and 7000 Soap Solutions Sodium Hydroxide Steam, Below 350ÞF * Steam, Above 350ÞF Stoddard Solvent * Sulphuric Acid Toluene Transformer Oil Transmission Fluid Type A Trisodium hosphate Turbine Oil Turpentine Water *Consult factory for port and diaphragm materials olyimide diaphragm not suitable for water applications above 140 F

12 Conversion Tables Temperature Conversion Table - Formula C=5/9 ( F 32 ) F=(9/5 C) +32 C F C F C F C F C F ressure Conversion Formulas INTO MULTILY BY TO CONVERT SI "H 2 O (15 C) mmhg (0 C) "Hg (0 C) Millibar Bar Kg/Cm 2 ka SI "H 2 O (15 C) mmhg (0 C) "Hg (0 C) Millibar Bar Kg/Cm ka The use of ITT Industrial Controls pressure, temperature and flow switches must be in accordance with the provisions of the National Electric Code, U.L. and/or other local, military or industry standards that are pertinent to the particular end use. Installation or use not in accordance with these codes and standards could be hazardous to personnel and/or equipment. Note: It is buyer s responsibility to determine the suitability of the Neo-Dyn switch for its application. ITT Industrial Controls makes no warranties and assumes no liability as to the suitability or sufficiency for buyer s application of the switch. Underwriters Laboratories, Inc. Listing and CSA International Certification Data. The following listings are extracted from official Underwriters Laboratories, Inc. and CSA International records. Verification of the listings may be obtained from the respective organization by referencing the file number or by requesting a file card from the factory CSA INTERNATIONAL Class ITT Industries, Valencia, CA SWITCHES - Automatic - ressure Type ressure switches, weatherproof enclosure, Series 115*C3**X, SDT and 115*CC3**X, DDT ressure switches, adjustable, water-tight enclosure (CSA Encl. 4) Series 100, 101, 110, 130, 131, 132, 160 and 200. Series 125, 225, 225, with suffixes. File No UNDERWRITERS LABORATORIES,. Guide WSQX.E56677 Nov. 27, 2002 Snap Switches for Use in Hazardous Locations. ITT Industries, Valencia, CA Class I, Groups A, B, C and D; Class II, Groups E, F and G. Cat. Nos , , and The switches are provided with factory seals of conductors entering the switch enclosures. File No. E56677 CSA INTERNATIONAL Class Feb. 18, 2004 ITT Industries, Valencia, CA SWITCHES - Snap - For Hazardous Locations. Class I, Groups A, B, C and D; Class II, Groups E, F and G. Snap Switch, Cat. Nos , SDT, and , DDT, each rated 11 amp, ¼ hp, 125 or 250Vac, 5 amp resistive, 30Vdc max;.5 amp, 125Vdc; leads factory sealed. Snap Switch, Cat. Nos , SDT, and , DDT, each rated Vac and 1 amp resistive,.5 amp 28 Vdc max, leads factory sealed. File No Form #091-11/14

13 Neo-Dyn Electrical Assembly Specification ELECTRICAL RATINGS - T RATINGS - AMBIENT TEMERATURES SWITCH CONFIGURATION ELECTRICAL RATING MAX AMBIENT OERATING TEM ºC (ºF) TEMERATURE CODE (MAX SURFACE TEM) FORM C SDT FORM CC DDT M OTION FORM C & CC (SDT) (DDT) 11 AM OR ¼ H AT 125 OR 250 VAC 5 AM AT 125 OR 250 VAC; 5 AM RES, 3 AM IND AT 28 VDC; 0.5 AM RES AT 125 VDC 11 AM OR ¼ H AT 125 OR 250 VAC 5 AM AT 125 OR 250 VAC; 5 AM RES, 3 AM IND AT 28 VDC; 0.5 AM RES AT 125 VDC 1 AM AT 125 VAC; 1 AM RES, 0.5 AM IND AT 28 VDC 75 (167) 60 (140) 70 (158) 65 (149) 45 (113) 70 (158) T5 T6 T4A 70 (158) T6 T6 All Standard 6 - ressure and Temperature Switches carry one of the electrical assemblies listed in the Table above and are suitable for the following Hazardous Locations: Zone 1 and 2, EEx d IIC Division 1 and 2; Class I, Groups A, B, C, and D; Class II, Groups E, F, and G These assemblies carry one or all of the following agency listings: Underwriters Laboratories, Inc., File number E56677 CSA International, File number LR34146 Factory Mutual, File number J.1.IR5A9.AE SIRA, 10ATEX1017X and 1ECEx SR X NCC 6574/10X for INMETRO Neo-Dyn Industry Drive Valencia, CA tel: fax: Form #092-11/14

14 Neo-Dyn Temperature Limitations for ressure Switches ressure switch applications often have media temperatures that are in excess of our published specifications. Even though most of Neo-Dyn s switches can actually withstand temperatures higher than those listed, they are published for varying reasons that include effects on; set point shift, decreased life expectancy, or in some cases, damage. O-rings themselves have limitations even though they are capable of temperatures higher than those we publish for the switches. Generally speaking, Buna-N and ER are good up to 250 F (121ºC), Viton up to 400 F (204ºC). The welded assemblies have no o-rings at all. The main purpose of this bulletin is to advise the end user that the media temperature limitations of these switches can be overcome by simply increasing the distance of the switch from the source of the media. Since Neo-Dyn s pressure switches are dead-ended devices, the temperature at the diaphragm or piston will not be the same as it is at the media. Often a 1 ft. (30.46 cm) length of uninsulated 1/4 inch, SS tubing is enough to lower the temperature to within published specifications. The rule of thumb utilized for these applications is as follows: For every 2 ft. (60.96 centimeters) of uninsulated-1/4 inch-ss tubing, you dissipate 100 ºF (37.77 ºC), in excess of +200 ºF (+93.3 ºC). It will of course depend on the initial media temperature, type of media, ambient temperature, and piping size & material. In some cases a longer capillary may be the best solution. Typically the tubing is coiled, so as to conserve space (pig tail). There are also other methods for dissipating heat, such as condensate chambers or reservoirs filled with liquid, which will act in the same manner as a diaphragm seal in isolating and dissipating the heat. These methods are better explained in ISA, ASME or other such industry and engineering standard practice texts. Should you have further questions or require additional information, please contact your Regional Sales Manager or the factory directly. For more information, please visit Neo-Dyn Industry Drive Valencia, CA tel: fax: Form #093-1/15

15 Neo-Dyn Repeatability, Accuracy and Maintenance for ressure Switches REEATABILITY Repeatability is the maximum set point deviation of a single pressure switch under one given set of environmental and operational conditions. Since adjustable pressure switches can be set at any discrete set point within its given adjustable range this is the most common performance criteria stated by the manufacturer. A general repeatability statement is that a ITT Neo-Dyn pressure switch will repeat within ± 0.5% of its set point when set in the upper 80% of its adjustable range for set points above 10 psig. Exceptions to this statement could include piston sensor pressure switches and switches whose adjustable range is inches of water. ACCURACY Accuracy is a term generally associated with analog instruments such as transducers and transmitters. Since a pressure switch is meant to give a contact opening or closure at a discrete set point an accuracy statement can only be given if all operational and environmental conditions are clearly defined. For example, what is the accuracy of an Neo-Dyn model 10012C3 when set at 150 psig increasing pressure when cycled between 150 psig and 130 psig for 500 cycles over a temperature range of +40 to +160 degrees Fahrenheit at a cycle rate of 15 cycles per minute. Again, the model, the operational and environmental conditions must all be defined. ITT Neo-Dyn can provide limited testing on some of its models under various test conditions. MAINTENANCE Under normal circumstances ITT Neo-Dyn pressure switches do not require maintenance or recalibration. For critical applications or those where the switches are used in a severe environment, it is suggested a calibration check be performed at intervals based upon actual in service stability data. For more information, please visit Neo-Dyn Industry Drive Valencia, CA tel: fax: Form #094-1/15

16 Neo-Dyn Switch Selection Questions 1 Does the Switch Have to Be adjustable? Tamper-proof, tamper-resistant, fixed or adjustable 2 Normal System ressure? Tells the pressure the switch normally sees 3 Critical Set oint? Tells us the range required Tells us if the set point is increasing or decreasing and if the deadband of the switch is important 4 What is the rocess Being Sensed? Confirms the wetted materials 5 What is the Function of the Switch? Will confirm SDT or DDT 6 Is the Swtich Going into a Hazardous Area (Listed)? Confirms electrical classifaction requirements Neo-Dyn Industry Drive Valencia, CA tel: fax:

17 GENERAL UROSE RESSURE SWITCHES déåéê~ä=mìêéçëé=té~íüéê=mêççñ NMMm=pÉêáÉë Internally Adjustable NMNm=pÉêáÉë Externally Adjustable NNMm=pÉêáÉë Low ressure Range NQOm=pÉêáÉë Ultra Low ressure Range OMMm=pÉêáÉë= Hydraulic Service - Internally Adjustable OMNm=pÉêáÉë Hydraulic Service - Externally Adjustable ^Çàìëí~ÄäÉ 1 NEMA 4, 4X & 13 `çãé~åí=té~íüéê=mêççñ NOm=pÉêáÉë neumatic or Low Impulse Hydraulic OOm=pÉêáÉë High ressure or High Impulse Hydraulic ^Çàìëí~ÄäÉ 2 lbj péêáéë=té~íüéê=mêççñ= NMm=pÉêáÉë Adjustable Thru ort Cap ressure NNm=pÉêáÉë Adjustable With Selectable Deadband ressure ONm=pÉêáÉë Adjustable Hydraulic Switch ^Çàìëí~ÄäÉ 3 q~ãééê=mêççñ péêáéë NMRm=pÉêáÉë Miniature ressure Switch 11Rm=pÉêáÉë Build-To-Order Set oints NORm=pÉêáÉë Higher Range neumatic Applications OORm=pÉêáÉë High ressure Hydraulic Applications c~åíçêó=péí 4 HAZARDOUS AREA RESSURE SWITCHES NEMA 7 & 9 eéêãéíáå~ääó=pé~äéçlbñéäçëáçå=mêççñ= NMMm=EbåÅäK=RF=pÉêáÉë Div 2 W/Terminal Strip NMMm=EbåÅäK=SF=pÉêáÉë Div 1 and 2 Hermetic NMMm=EbåÅäK=TF=pÉêáÉë Div 1 W/Terminal Strip NNMm=EbåÅäK=RF=pÉêáÉë Div 2 W/Terminal Strip Low Range NNMm=EbåÅäK=SF=pÉêáÉë Div 1 and 2 Hermetic Low Range NQOm=pÉêáÉë Div 1 and 2 Hermetic Ultra Low Range OMMm=pÉêáÉë Div 1 and 2 Hermetic Hydraulic `çãé~åí=eéêãéíáå~ääó=pé~äéçlbñéäçëáçå=mêççñ= NNOm=pÉêáÉë ANSI Flanged ressure Switch NOOm=pÉêáÉë CI ressure Switch NOm=pÉêáÉë Flush Welded Diaphragm NOm=pÉêáÉë Universal ressure Switch OOm=pÉêáÉë High ressure Hydraulic ^Çàìëí~ÄäÉ ^Çàìëí~ÄäÉ 5 6 lbj=péêáéë=eéêãéíáå~ääó=pé~äéçlbñéäçëáçå=mêççñ= NMm=pÉêáÉë Adjustable Thru ort Cap ressure NNm=pÉêáÉë Adjustable With Selectable Deadband ressure ONm=pÉêáÉë Adjustable Hydraulic ^Çàìëí~ÄäÉ 7 q~ãééê=mêççñ=eéêãéíáå~ääó=pé~äéçlbñéäçëáçå=mêççñ= NNRm=pÉêáÉë Build-To-Order Set oints NORm=pÉêáÉë Higher Range neumatic Applications OORm=pÉêáÉë=Ó=High ressure Hydraulic Applications c~åíçêó=péí 8

18 Neo-Dyn Neo-Dyn Series 100 Operating ressure Data Standard Specifications Electrical Snap action electrical switch recognized by Underwriters Laboratories, Inc. and CSA International Electrical Connection 1/2 NT female conduit connection with terminal block ressure Connection 1 1/4 NT Female 4, 5, 7 and 9 1/2 NT Female Temperature Range Ambient: - 40 F to +180 F (-40 C to +82 C) Media: - 40 F to +300 F (-40 C to +149 C) Media temperature limits change with O-Ring selection Concealed wrench flat adjustment with range scale Shipping Weight Approximately 3 pounds ressure Switch/Internal Versatile Nega-Rate Belleville disc spring pressure switch for a wide range of applications. Series 100 (diaphragm sensor) for pneumatic and low impulse hydraulics up to 3000 psig system pressure. Adjustable Range Number All values given in psig. Order Option D Adjustable Set oint Range Increasing 5 to to to to to to 2800 Weather roof (NEMA 4 and 13) Decreasing 2.3 to to to to to to 2675 Deadband (approximate) Ordering Sequence Select desired option for each category OTIONS 1 Aluminum port, Teflon coated polyimide diaphragm and Buna-N O-Ring stainless steel port, Teflon coated polyimide diaphragm and Buna-N O-Ring stainless steel port and diaphragm heliarc welded 7 Hastelloy C port and diaphragm, heliarc welded (Except Range 1) 9 Monel port and inconel diaphragm heliarc welded (Except Range 1) psig dec. to 75 psig inc. (0.2 bar dec. to 5.2 bar inc.) 2 9 psig dec. to 150 psig inc. (0.6 bar dec. to 10.3 bar inc.) 4 36 psig dec. to 300 psig inc. (2.5 bar dec. to 20.7 bar inc.) psig dec. to 600 psig inc. (6.9 bar dec. to 41.4 bar inc.) psig dec. to 1500 psig inc. (30.3 bar dec. to bar inc.) psig dec. to 2800 psig inc. (46.5 bar dec. to bar inc.) C 15 amp at 125 or 250 VAC; 1/8, hp at 125 VAC; 1/4 hp at 250 VAC;.5 amp resistive,.04 amp inductive at 125 VDC CC 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; Z 15 amp at 125 or 250 VAC; 1/4 hp at 125 VAC; 1/2 hp at 250 VAC; 1 amp resistive,.5 amp inductive at 125 VDC 3 Meets or exceeds the requirements of NEMA Type 3, 3R, 3S, 4, 4X and 13 A Epoxy paint exterior extra protection for severe environments B Viton O-Ring C ER O-Ring D SIL approval and marking, per IEC61508 (includes FMEA report) E 7/16 " - 20 SAE port ( 1 Only) F Fire fuse for fire-tested equipment ( 4 & 5 only) J Annealed stainless steel port screws for H2S environments (s 4 and 5 only) Consult factory for reduced system and proof pressure L Neon indicator light 115 VAC M Gold electrical contacts for extremely low current applications 5-in Brad Harrison connector (Reduce AC ele ctrical rating to 8 amps (Not for CC3 Electrical) S Stainless steel diaphragm ( 4 only) W Stainless steel screws exterior (Standard with s 4, 5, 7 and 9) X UL and CSA Approved and CE Mark (Not available with L or option) Y 2" NT Female port for viscous medias. ort Material is carbon steel ( 3 ) Order as 1003xxxxY Special (Consult representative or factory) Non-catalog adjustable range and/or set point, deadband and proof pressure Media temperature capability from -65 F to +400 F Chemical seals installed Manual reset decreasing only (available in C3 only) 10 amps 125 VDC electrical rating Ordering rocedure When factory presetting is desired, stipulate set point, increasing or decreasing Insert available option number or letter designation as required Maximum Recommended System ressure Example C3_ Series roof ressure

19 Field Adjustable 2.3 to 2800 psig Series 100 Envelope Dimensions 3.50 (range 1) 3.31 (range 2-8) (range 2-8) SCREW FORM "C" (SDT) BLK YEL VIO NC2 C2 NO2 FORM "CC" (DDT) FORM "Z" (DOUBLE BREAK) NC NC NO SCREW NO BLK VIO SCREW Basic rinciples of Design Neo-Dyn Industry Drive Valencia, CA tel: fax: AER0935_1 7/13 Specifications and dimensions subject to change.

20 Neo-Dyn Neo-Dyn Series 101 ressure Switch/External Versatile Nega-Rate Belleville disc spring pressure switch for a wide range of applications. Series 101 (diaphragm sensor) for pneumatic and low impulse hydraulics up to 3000 psig system pressure. Operating ressure Data Adjustable Range Number All values given in psig. Standard Specifications Electrical Snap action electrical switch recognized by Underwriters Laboratories, Inc. and CSA International Electrical Connection 1/2 NT female conduit connection with terminal block ressure Connection 1 1/4 NT Female 4 1/2 NT Female Temperature Range* Ambient: - 40 F to +180 F (-40 C to +82 C) Media: - 40 F to +300 F (-40 C to +149 C) *Temperature limits change with O-Ring selection External screwdriver slot adjustment and range scale Shipping Weight Approximately 3 pounds Order Option D Adjustable Set oint Range Increasing 5 to to to to to to 2800 Weather roof (NEMA 4 and 13) Decreasing 2.3 to to to to to to 2675 Deadband (approximate) Ordering Sequence Select desired option for each category OTIONS 1 Aluminum port, Teflon coated polyimide diaphragm and Buna-N O-Ring stainless steel port, Teflon coated polyimide diaphragm and Buna-N O-Ring stainless steel port and diaphragm heliarc welded 7 Hastelloy C port and diaphragm, heliarc welded (Except Range 1) 9 Monel port and inconel diaphragm heliarc welded (Except Range 1) psig dec. to 75 psig inc. (0.2 bar dec. to 5.2 bar inc.) 2 9 psig dec. to 150 psig inc. (0.6 bar dec. to 10.3 bar inc.) 4 36 psig dec. to 300 psig inc. (2.5 bar dec. to 20.7 bar inc.) psig dec. to 600 psig inc. (6.9 bar dec. to 41.4 bar inc.) psig dec. to 1500 psig inc. (30.3 bar dec. to bar inc.) psig dec. to 2800 psig inc. (46.5 bar dec. to bar inc.) C 15 amp at 125 or 250 VAC; 1/8, hp at 125 VAC; 1/4 hp at 250 VAC;.5 amp resistive,.04 amp inductive at 125 VDC Z 15 amp at 125 or 250 VAC; 1/4 hp at 125 VAC; 1/2 hp at 250 VAC; 1 amp resistive,.5 amp inductive at 125 VDC 3 Meets or exceeds the requirements of NEMA Type 3, 3R, 3S, 4, 4X and 13 A Epoxy paint exterior extra protection for severe environments B Viton O-Ring C ER O-Ring D SIL approval and marking, per IEC61508 (includes FMEA report) E 7/16" - 20 SAE port ( 1 only) K External adjustment knob L Neon indicator light 115 VAC M Gold electrical contacts for extremely low current applications 5-in Brad Harrison connector (Reduce AC electrical rating to 8 amps) (Not for CC3 Electrical) S Stainless steel diaphragm ( 4 only) X CSA Approved and CE Mark (Not available with L or option) ( 4 only; Not available with Range 1) Y 2" NT Female port for viscous medias. ort Material is carbon steel ( 3 ) Order as 1013xxxxY Special (Consult representative or factory) Non-catalog adjustable range and/or set point Operating temperature capability from -65 F to +400 F Wide deadband 10 amps 125 VDC electrical rating Ordering rocedure When factory presetting is desired, stipulate set point, increasing or decreasing Insert available option number or letter designation as required Maximum Recommended System ressure Example C 3_ Series roof ressure

21 Field Adjustable 2.3 to 2800 psig Series 101 Envelope Dimensions Adjustable Range 1 Knob (range 1) (range 1) (range 4-9) Adjustable Range Conduit Connection ¹ ₂ NT (range 1 only) Range Scale.265 Dia. Mtg. Holes (2 places) Conduit Connection ¹ ₂ NT (range 2-8) (range 4-9) ressure ort ¹ ₄ NT (wetted material 1) ¹ ₂ NT (wetted material 4-9) FORM "C" (SDT) FORM "Z" (DOUBLE BREAK) NC NC BLK SCREW NO SCREW NO VIO Basic rinciples of Design Snap Action Electrical Element Actuator Minimum Bearing oints O-Ring Diaphragm ressure ort Terminal Strip ressure late Negative Rate Belleville Disc Spring Neo-Dyn Industry Drive Valencia, CA tel: fax: AER0935_9 7/13 Specifications and dimensions subject to change.

22 Neo-Dyn Neo-Dyn Series 110 ressure Switch/Internal Sensitive Nega-Rate Belleville spring adjustable pressure switch for low pressure applications. Operating ressure Data Adjustable Range Number 2 4 Adjustable Set oint Range Increasing 10" H 2 0 to 100" H to 15 Decreasing 7" H 2 0 to 97" H to Deadband (approximate) 3" H Maximum Recommended System ressure roof ressure All values given in psig. Standard Specifications Electrical Snap action electrical switch recognized by Underwriters Laboratories, Inc. and CSA International Electrical Connection 1/2 NT female conduit connection with terminal block ressure Connection 1 1/4 NT Female 4 1/2 NT Female Temperature Range* Ambient: - 40 F to +180 F (-40 C to +82 C) Media: - 40 F to +300 F (-40 C to +149 C) *Temperature limits change with O-Ring selection Concealed wrench flat adjustment with range scale Shipping Weight Approximately 3 pounds Order Option D Ordering Sequence Select desired option for each category OTIONS 1 Aluminum port, Teflon coated polyimide diaphragm and Buna-N O-Ring stainless steel port, Teflon coated polyimide diaphragm and Buna-N O-Ring 2 7" H 2 0 dec. to 100" H 2 0 inc. (17 millibar dec. to 249 millibar inc.) psig dec. to 15 psig inc. (0.2 bar dec. to 1.0 bar inc.) C 15 amp at 125 or 250 VAC; 1/8 hp at 125 VAC; 1/4 hp at 250 VAC;.5 amp resistive,.04 amp inductive at 125 VDC CC 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; Z 15 amp at 125 or 250 VAC; 1/4 hp at 125 VAC; 1/2 hp at 250 VAC; 1 amp resistive,.5 amp inductive at 125 VDC 3 Meets or exceeds the requirements of NEMA Type 3, 3R, 3S, 4, 4X and 13 A Epoxy paint exterior extra protection for severe environments B Viton O-Ring C ER O-Ring D SIL approval and marking, per IEC61508 (includes FMEA report) F Fire fuse for fire-tested equipment ( 4 only; not available with G) G 1/2 NT male port ( 4 only) L Neon indicator light 115 VAC M Gold electrical contacts for extremely low current applications 5-in Brad Harrison connector (Reduce AC electrical rating to 8 amps) (Not for CC3 Electrical) S Stainless steel diaphragm ( 4 only) W Stainless steel screws exterior (Standard with 4) X UL and CSA Approved and CE Mark (Not available with L or option) Special (Consult representative or factory) Non-catalog adjustable range and/or set point, deadband and proof pressure Chemical seals installed Ordering rocedure Example Weather roof (NEMA 4 and 13) When factory presetting is desired, stipulate set point, increasing or decreasing Insert available option number or letter designation as required C 3_ Series

23 Field Adjustable 7" H 2 O to 15 psig Series 110 Envelope Dimensions A 2.72 C B ressure ort Dia. Mtg. Holes (2 places) Conduit Connection ¹ ₂ NT 3.1 WETTED MATERIALS A B ¹ ₄ NT ¹ ₂ NT C Dia..45 FORM "C" (SDT) FORM "CC" (DDT) FORM "Z" (DOUBLE BREAK) NC NC BLK SCREW BLK YEL VIO NC2 C2 NO2 NO SCREW NO VIO SCREW Basic rinciples of Design Actuator Diaphragm O-Ring Snap Action Electrical Element Terminal Strip ressure ort ressure late Negative Rate Belleville Disc Spring Neo-Dyn Industry Drive Valencia, CA tel: fax: AER0935_11 7/13 Specifications and dimensions subject to change.

24 Neo-Dyn Neo-Dyn Series 1428 Ultra Low Vacuum/ressure Switch Ultra low pressure and vacuum to pressure crossover switch. Unique construction using efficient Nega-Rate Belleville disc spring for stable set points and high proof pressure. Wide range of wetted materials makes this series well suited for applications that formerly required the use of diaphragm seals. Operating ressure Data Adjustable Range Number Adjustable Set oint Range Increasing Deadband* (approximate) Maximum Recommended System ressure roof ressure 0 1" to 10" H 2 O.75" H 2 O 30" H 2 O Vacuum to 30" H 2 O ressure 30" H 2 O Vacuum to +5 psig 1 2" to 40" H 2 O 1" H 2 O 30" H 2 O Vacuum to +5 psig 30" H 2 O Vacuum to +15 psig 2 0" to 40" H 2 O Vacuum to 0" to 40" H 2 O ressure 1" H 2 O Full Vacuum to +15 psig Full Vacuum to 100 psig *Deadband 50% wider with "CC" (DDT) and "Z" (Double Break) s. Standard Specifications Electrical Snap action electrical switch recognized by Underwriters Laboratories, Inc. and CSA International Electrical Connection 1/2 NT female conduit connection with terminal block ressure Connection 1/2 NT Female Temperature Range* Ambient: - 40 F to +180 F (-40 C to +82 C) Media: - 50 F to +250 F (-46 C to +121 C) *Temperature limits change with O-Ring selection Concealed wrench flat adjustment with range scale Shipping Weight Approximately 3.5 pounds Order Option D Ordering Sequence Select desired option for each category OTIONS 0.25" H 2 O (.62 mbar) dec. to 10" (24.9 mbar) H 2 O inc. 1 1" H 2 O (2.49 mbar) dec. to 40" (99.6 mbar) H 2 O inc. 2 40" H 2 O (99.6 mbar) inc. vac. to 40" (99.6 mbar) H 2 O inc. pressure C 15 amp at 125 or 250 VAC; 1/8 hp at 125 VAC; 1/4 hp at 250 VAC;.5 amp resistive,.04 amp inductive at 125 VDC CC 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive 28 VDC; Z 15 amp at 125 or 250 VAC; 1/4 hp at 125 VAC; 1/2 hp at 250 VAC; 1 amp resistive,.5 amp inductive at 125 VDC 3 Meets or exceeds the requirements of NEMA Type 3 3R, 3S, 4, 4X and 13 A Epoxy paint exterior extra protection for severe environments D SIL approval and marking, per IEC61508 (includes FMEA report) L Neon light indicator 115 VAC M Gold electrical contacts for extremely low current applications ort Material Stainless Steel 7 Hastelloy C Diaphragm 1 olyimide Stainless Steel 6 Tantalum 7 Hastelloy C O-Rings 2 Kalrez 3 Viton 5 ER 8 Buna-N Special (Consult representative or factory) Non-catalog adjustable range and/or set point and deadband Operating temperature capabilities from -65 F to 400 F Weather roof (NEMA 4 and 13) Ordering rocedure When factory presetting is desired, stipulate set point, increasing or decreasing Insert available option number or letter designation as required Example CC3_ 463 Series ort Material Diaphragm O-Rings

25 Field Adjustable 40" H 2 O vac. to 40" H 2 O Series 142 Envelope Dimensions Dia Conduit Connection ¹ ₂ NT Dia. Mtg. Holes (2 places) Reference ort ¹ ₄ NT DO NOT LUG Random Radial Location ressure ort ¹ ₂ NT FORM "C" (SDT) FORM "CC" (DDT) FORM "Z" (DOUBLE BREAK) NC NC BLK SCREW BLK YEL VIO NC2 C2 NO2 NO SCREW NO VIO SCREW Basic rinciples of Design Reference ort Negative Rate Belleville Disc Spring Snap Action Electrical Element Actuator ressure late Diaphragm ressure ort Terminal Strip O-Rings Neo-Dyn Industry Drive Valencia, CA tel: fax: AER0935_30 7/13 Specifications and dimensions subject to change.

26 Neo-Dyn Neo-Dyn Series 200 ressure Switch/Internal Versatile Nega-Rate Belleville disc spring pressure switch for a wide range of applications. Series 200 (piston sensor) for hydraulic applications up to psig system pressure. Operating ressure Data Adjustable Range Adjustable Set oint Range Deadband (approximate) Number Increasing 20 to to to to Decreasing 14 to to to to 9000 Min All values given in psig. The deadband increases as the adjustable set point is increased. *Diminished safety factor equal to approximately 2:1. **Diminished safety factor equal to approximately 1.3:1. Maximum Recommended System ressure * roof ressure ** Standard Specifications Electrical Snap action electrical switch recognized by Underwriters Laboratories, Inc. and CSA International Electrical Connection 1/2 NT female conduit connection with terminal block ressure Connection 1 1/4 NT Female Temperature Range* Ambient: - 40 F to +180 F (-40 C to +82 C) Media: - 40 F to +300 F (-40 C to +149 C) *Temperature limits change with O-Ring selection Concealed wrench flat adjustment with range scale Shipping Weight Approximately 3 pounds Order Option D Ordering Sequence Select desired option for each category OTIONS 1 Aluminum port and piston, Teflon seal and Buna-N O-Ring 2 14 psig dec. to 220 psig inc. (1.0 bar dec. to 15.2 bar inc.) psig dec. to 1500 psig inc. (10.3 bar dec. to bar inc.) psig dec. to 3000 psig inc. (25.9 bar dec. to bar inc.) psig dec. to psig inc. (55.2 bar dec. to bar inc.) C 15 amp at 125 or 250 VAC; 1/8 hp at 125 VAC; 1/4 hp at 250 VAC;.5 amp resistive,.04 amp inductive at 125 VDC CC 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; Z 15 amp at 125 or 250 VAC; 1/4 hp at 125 VAC; 1/2 hp at 250 VAC; 1 amp resistive,.5 amp inductive at 125 VDC 3 Meets or exceeds the requirements of NEMA Type 3, 3R, 3S, 4, 4X and 13 A Epoxy paint exterior extra protection for severe environments B Viton O-Ring C ER O-Ring D SIL approval and marking, per IEC61508 (includes FMEA report) E 7/16" - 20 SAE port L Neon indicator light 115 VAC M Gold electrical contacts for extremely low current applications 5-in Brad Harrison connector (Reduce AC electrical rating to 8 amps) (Not for CC3 Electrical) W Stainless steel screws exterior X UL and CSA Certified with CE Mark (Not available with L or option) Special (Consult representative or factory) Non-catalog adjustable range and/or set point, deadband and proof pressure Operating temperature capability from -65 F to +400 F Manual reset decreasing only (available in C3 only) 10 amps 125 VDC electrical rating Ordering rocedure Example Weather roof (NEMA 4 and 13) When factory presetting is desired, stipulate set point, increasing or decreasing Insert available option number or letter designation as required C 3_ Series

27 Field Adjustable 14 to psig Series 200 Envelope Dimensions essure ort ¹ ₄ NT Dia. Mtg. Holes (2 places) Conduit Connection ¹ ₂ NT FORM "C" (SDT) FORM "CC" (DDT) FORM "Z" (DOUBLE BREAK) NC NC BLK SCREW BLK YEL VIO NC2 C2 NO2 NO SCREW NO VIO SCREW Basic rinciples of Design Snap Action Electrical Element Terminal Strip Actuator Minimum Bearing oints Teflon and O-Ring Seal iston Negative Rate Belleville Disc Spring ressure ort Neo-Dyn Industry Drive Valencia, CA tel: fax: AER0935_43 7/13 Specifications and dimensions subject to change.

28 Neo-Dyn Neo-Dyn Series 201 ressure Switch/External Versatile Nega-Rate Belleville disc spring pressure switch for a wide range of applications. Series 201 (piston sensor) for hydraulic applications up to psig system pressure. Externally adjustable for convenient set point changes. Operating ressure Data Adjustable Range Adjustable Set oint Range Deadband (approximate) Number Increasing 20 to to to to Decreasing 14 to to to to 9000 Min All values given in psig. The deadband increases as the adjustable set point is increased. *Diminished safety factor equal to approximately 2:1. **Diminished safety factor equal to approximately 1.3:1. Standard Specifications Electrical Snap action electrical switch recognized by Underwriters Laboratories, Inc. and CSA International Electrical Connection 1/2 NT female conduit connection with terminal block ressure Connection 1 1/4 NT Female Temperature Range* Ambient: - 40 F to +180 F (-40 C to +82 C) Media: - 40 F to +300 F (-40 C to +149 C) *Temperature limits change with O-Ring selection External screwdriver slot adjustment and range scale Shipping Weight Approximately 3 pounds Order Option D Maximum Recommended System ressure * Ordering Sequence Select desired option for each category roof ressure ** OTIONS 1 Aluminum port and piston, Teflon seal and Buna-N O-Ring 2 14 psig dec. to 220 psig inc. (1.0 bar dec. to 15.2 bar inc.) psig dec. to 1500 psig inc. (10.3 bar dec. to bar inc.) psig dec. to 3000 psig inc. (25.9 bar dec. to bar inc.) psig dec. to psig inc. (55.2 bar dec. to bar inc.) C 15 amp at 125 or 250 VAC; 1/8 hp at 125 VAC; 1/4 hp at 250 VAC;.5 amp resistive,.04 amp inductive 125 VDC Z 15 amp at 125 or 250 VAC; 1/4 hp at 125 VAC; 1/2 hp at 250 VAC; 1 amp resistive,.5 amp inductive 125 VDC 3 Meets or exceeds the requirements of NEMA Type 3, 3R, 3S, 4, 4X and 13 A Epoxy paint exterior extra protection for severe environments B Viton O-Ring C ER O-Ring D SIL approval and marking, per IEC61508 (includes FMEA report) E 7/16" - 20 SAE port K External adjustment knob L Neon indicator light 115 VAC M Gold electrical contacts for extremely low current applications 5-in Brad Harrison connector (Reduce AC electrical rating to 8 amps) X CSA Certified with CE Mark (Not available with L or option) Special (Consult representative or factory) Non-catalog adjustable range and/or set point Media temperature capability from -65 F to +400 F Wide deadband 10 amps 125 VDC electrical rating Ordering rocedure Example Weather roof (NEMA 4 and 13) When factory presetting is desired, stipulate set point, increasing or decreasing Insert available option number or letter designation as required C 3_ Series

29 Field Adjustable 14 to psig Series 201 Envelope Dimensions Range Scale essure ort ¹ ₄ NT Dia. Mtg. Holes (2 places) Conduit Connection ¹ ₂ NT FORM "C" (SDT) FORM "Z" (DOUBLE BREAK) NC NC BLK SCREW NO SCREW NO VIO Basic rinciples of Design Snap Action Electrical Element Actuator Minimum Bearing oints Teflon and O-Ring Seal Terminal Strip iston Negative Rate Belleville Disc Spring ressure ort Neo-Dyn Industry Drive Valencia, CA tel: fax: AER0935_45 7/13 Specifications and dimensions subject to change.

30 Neo-Dyn Neo-Dyn Series 132 ressure Switch/Internal Compact, adjustable pressure switch for pneumatic or low impulse hydraulic process applications. Efficient Nega-Rate Belleville disc spring for set point stability and vibration resistance. Operating ressure Data Adjustable Range Number All values given in psig. Standard Specifications Electrical Snap action electrical switch recognized by Underwriters Laboratories, Inc. and CSA International Electrical Connection 1/2 NT male conduit connection with VC insulated 18 AWG, 18" long leads ressure Connection 1/4 NT Female Temperature Range* Ambient: - 40 F to +180 F (-40 C to +82 C) Media: - 40 F to +250 F (-40 C to +121 C) * Temperature limits change with O-Ring selection Internal, slotted adjustment nut with range scale Shipping Weight Approximately 20 ounces Order Option D Adjustable Set oint Range Deadband Increasing 3 to to to to to to to to 2300 Decreasing 1 to to to to to to to to 2200 (approximate) * See T for higher pressures. Maximum Recommended System ressure * 4000* 4000* 4000* 4000* Ordering Sequence Select desired option for each category OTIONS stainless steel port and diaphragm, Buna-N O-Ring stainless steel port and diaphragm heliarc welded 8 1 psig dec. to 30 psig inc. (0.1 bar dec. to 2.1 bar inc.) 9 15 psig dec. to 80 psig inc. (1.0 bar dec. to 5.5 bar inc.) 0 67 psig dec. to 130 psig inc. (4.6 bar dec. to 9.0 bar inc.) 1 30 psig dec. to 250 psig inc. (2.1 bar dec. to 17.2 bar inc.) psig dec. to 400 psig inc. (12.1 bar dec. to 27.6 bar inc.) psig dec. to 725 psig inc. (22.8 bar dec. to 50.0 bar inc.) psig dec. to 1500 psig inc. (42.7 bar dec. to bar inc.) psig dec. to 2300 psig inc. (96.5 bar dec. to bar inc.) C 11 amp, 1/4 hp 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; CC 11 amp, 1/4 hp 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; 3 Meets or exceeds the requirements of NEMA Type 3, 3R, 3S, 4, 4X and 13 A Epoxy paint exterior extra protection for severe environments B Viton O-Ring C ER O-Ring D SIL approval and marking, per IEC61508 (includes FMEA report) E 7/16" - 20 SAE Female ort G 1/2 NT Female ort I 3/4 NT Conduit Box with Terminal Strip J Annealed stainless steel port screws for H 2 S environments Consult factory for reduced system and proof pressure ratings M Gold electrical contacts for extremely low current applications O Cleaned for oxygen service R 72" Electrical free leads T 6300 psig system, 9450 psig proof, 410 stainless steel screws (Range 1 thru 7 only) X UL and CSA Approval and CE Marked Special (Consult representative or factory) Non-catalog adjustable range and/or set point, deadband and proof pressure roof ressure * 6000* 6000* 6000* 6000* Weather roof (NEMA 4 and 13) Ordering rocedure When factory presetting is desired, stipulate set point, increasing or decreasing Insert available option number or letter designation as required Example CC3_ Series (specify)

31 Field Adjustable 1 to 2300 psig Series 132 Envelope Dimensions 1.50 (Typ.) Cover Free Leads 18 AWG 18" Long ressure ort Z\v or Z\x NT.209 Dia. Mtg. Holes (2 places) Conduit Connection Z\x NT FORM "C" (SDT) FORM "CC" (DDT) (X-OTION) GREEN BLK NC2 YEL C2 VIO NO2 (X-OTION) GREEN Basic rinciples of Design Actuator Minimum Bearing oints Diaphragm Snap Action Electrical Element Negative Rate Belleville Disc Spring O-Ring ressure ort Neo-Dyn Industry Drive Valencia, CA tel: fax: AER0935_25 8/13 Specifications and dimensions subject to change.

32 Neo-Dyn Neo-Dyn Series 232 ressure Switch/Internal Compact, adjustable pressure switch for high pressure hydraulic process applications. Efficient Nega-Rate Belleville disc spring for set point stability and vibration resistance. Operating ressure Data Adjustable Range Number All values given in psig. Adjustable Set oint Range Increasing 50 to to to to to to Decreasing 25 to to to to to to 9000 Deadband (approximate) Maximum Recommended System ressure roof ressure Standard Specifications Electrical Snap action electrical switch listed by Underwriters Laboratories, Inc. and CSA International Electrical Connection 1/2 NT male conduit connection with VC insulated 18 AWG, 18" long leads ressure Connection 1/4 NT Female Temperature Range* Ambient: -40 F to +180 F (-40 C to +82 C) Media: - 40 F to +250 F (-40 C to +121 C) * Temperature limits change with O-Ring selection Internal, slotted adjustment nut with range scale Shipping Weight Approximately 20 ounces Order Option D Ordering Sequence Select desired option for each category OTIONS stainless steel port and piston, Buna-N O-Ring 1 25 psig dec. to 275 psig inc. (1.7 bar dec. to 19.0 bar inc.) 2 75 psig dec. to 1000 psig inc. (5.2 bar dec. to 69.0 bar inc.) psig dec. to 3100 psig inc. (48.3 bar dec. to bar inc.) psig dec. to 6000 psig inc. (158.6 bar dec. to bar inc.) psig dec. to 8500 psig inc. (337.9 bar dec. to bar inc.) psig dec. to psig inc. (413.7 bar dec. to bar inc.) C 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; CC 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; 3 Meets or exceeds the requirements of NEMA Type 3, 3R, 3S, 4, 4X and 13 A Epoxy paint exterior extra protection for severe environments B Viton O-Ring C ER O-Ring D SIL approval and marking, per IEC61508 (includes FMEA report) E 7/16" - 20 SAE ort G 1/2 NT Female ort I 3/4 NT conduit box with terminal strip J Annealed stainless steel port screws for H2S environments Consult factory (Not available with range 4,5 & 6) M Gold electrical contacts for extremely low current applications (1 Amp at 125 VAC; 1 Amp Res, 0.5 Amp Ind. at 28 VDC) R 72" Electrical free leads X CE Mark Special (Consult representative or factory) Non-catalog adjustable range and/or set point, deadband and proof pressure Ordering rocedure Example Weather roof (NEMA 4 and 13) When factory presetting is desired, stipulate set point, increasing or decreasing Insert available option number or letter designation as required CC3_ Series (specify)

33 Field Adjustable 25 to psig Series 232 Envelope Dimensions SQ 1.8 Cover Free Leads 18 AWG 18" Long ressure ort Z\v NT.209 Dia. Mtg. Holes (2 places) Conduit Connection Z\x NT FORM "C" (SDT) FORM "CC" (DDT) (X-OTION) BLK NC2 YEL C2 VIO NO2 (X-OTION) Basic rinciples of Design Minimum Bearing oints Actuator Teflon & O-Ring Seal Snap Action Electrical Element Negative Rate Belleville Disc Spring iston ressure ort Neo-Dyn Industry Drive Valencia, CA tel: fax: AER0935_50 7/13 Specifications and dimensions subject to change.

34 Neo-Dyn Neo-Dyn Series 130 ressure Switch/Tamper Resistant Compact, versatile pressure switch for low to mid-range pressure applications. Features efficient Nega-Rate Belleville disc spring for stable set points, vibration resistance and field adjustability through the pressure port. Once adjustments are made and switch is installed, it becomes tamper proof. Operating ressure Data Adjustable Range Number All values given in psig. Standard Specifications Electrical Snap action electrical switch recognized by Underwriters Laboratories, Inc. and CSA International Electrical Connection 1/2 NT male conduit connection with VC insulated 18 AWG, 18" long leads ressure Connection 1/4 NT Male Temperature Range* Ambient: - 40 F to +180 F (-40 C to +82 C) Media: - 40 F to +300 F (-40 C to +149 C) *Temperature limits change with O-Ring selection 1/8" allen wrench through port Shipping Weight Approximately 13 ounces Order Option D Adjustable Set oint Range Increasing 2 to to to to to to 170 Decreasing 1 to 11 7 to to to to to 155 Deadband (approximate) Maximum Recommended System ressure Ordering Sequence Select desired option for each category OTIONS 1 Aluminum port, Teflon coated polyimide diaphragm, Buna-N O-Ring stainless steel port, Teflon coated polyimide diaphragm, Buna-N O-Ring 1 1 psig dec. to 12 psig inc. (0.1 bar dec. to 0.8 bar inc.) 2 7 psig dec. to 30 psig inc. (0.5 bar dec. to 2.1 bar inc.) 3 25 psig dec. to 50 psig inc. (1.7 bar dec. to 3.4 bar inc.) 4 44 psig dec. to 70 psig inc. (3.0 bar dec. to 4.8 bar inc.) 5 60 psig dec. to 120 psig inc. (4.1 bar dec. to 8.3 bar inc.) psig dec. to 170 psig inc. (7.2 bar dec. to 11.7 bar inc.) C 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; CC 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; 3 Meets or exceeds the requirements of NEMA Type 3, 3R, 3S, 4, 4X and 13 A Epoxy paint exterior extra protection for severe environments B Viton O-Ring C ER O-Ring D SIL approval and marking, per IEC61508 (includes FMEA report) I 1/2 NT Conduit box with terminal strip M Gold electrical contacts for extremely low current applications R 72" Electrical free leads S Stainless steel diaphragm ( 4 only) X UL and CSA approved and CE Mark Special (Consult representative or factory) Non-catalog adjustable range and/or set point, deadband and proof pressure roof ressure Ordering rocedure Example Weather roof (NEMA 4 and 13) When factory presetting is desired, stipulate set point, increasing or decreasing Insert available option number or letter designation as required C 3_ Series

35 Field Adjustable 1 to 170 psig Series 130 Envelope Dimensions ressure ort ¼ NT Conduit Connection ½ NT FORM "C" (SDT) FORM "CC" (DDT) BLK NC2 YEL C2 VIO NO2 (X OTION) Basic rinciples of Design Neo-Dyn Industry Drive Valencia, CA tel: fax: AER0935_ Specifications and dimensions subject to change.

36 Neo-Dyn Neo-Dyn Series 131 ressure Switch/Internal Compact, adjustable pressure switch for pneumatic or low impulse hydraulic process applications. Using our efficient Nega-Rate Belleville disc spring, we offer superior set point stability and vibration resistance. The 131 series pressure switch also has a selectable deadband feature which can be preset to fit most any application. Operating ressure Data Adjustable Range Adjustable Set oint Range Number Increasing Decreasing 2 * 1 to 24 3 * 17 to 42 4 * 1 to 50 5 * 45 to * 90 to * 140 to 200 All values given in psig unless otherwise noted. * Add selected deadband to decreasing pressure range. Standard Specifications Electrical Listings Snap action electrical switch recognized by Underwriters Laboratories, Inc. and CSA International Electrical Connection 1/2 NT male conduit connection with VC insulated 18 AWG, 18" long leads ressure Connection 1/4 NT Female and 1/2 NT Male Temperature Range* Ambient: - 40 F to +180 F (-40 C to +82 C) Media: - 40 F to +300 F (-40 C to +149 C) * Temperature limits change with O-Ring selection Internal, slotted adjustment wheel Shipping Weight Approximately 20 ounces Order Option D Selectable Deadband at a Specified Set oint 1.5 to 2 3 to 6 6 to 11 7 to 11 7 to to 21 Default Deadband (approx.) Maximum Recommended System ressure Ordering Sequence Select desired option for each category OTIONS 1 Aluminum port, polyimide diaphragm, Buna-N O-Ring stainless steel port, polyimide diaphragm, Buna-N O-Ring 2 1 psig dec. to 26 psig inc. (.069 bar dec. to 1.79 bar inc.) 3 17 psig dec. to 46 psig inc. (1.17 bar dec. to 3.17 bar inc.) 4 1 psig dec. to 58 psig inc. (.069 bar dec. to 4.00 bar inc.) 5 45 psig dec. to 108 psig inc. (3.10 bar dec. to 7.44 bar inc.) 6 90 psig dec. to 162 psig inc. (6.21 bar dec. to 11.1 bar inc.) psig dec. to 216 psig inc. (9.65 bar dec. to 14.9 bar inc.) C 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; CC 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; 3 Meets or exceeds the requirements of NEMA Type 3, 3R, 3S, 4, 4X and 13 A Epoxy paint exterior extra protection for severe environments B Viton O-Ring C ER O-Ring D SIL approval and marking, per IEC61508 (includes FMEA report) E 7/16" - 20 SAE Female ort G 1/2 NT Female ort I 3/4 NT Conduit box with terminal strip J Annealed stainless steel port screws for H 2 S environments Consult factory for reduced system and proof pressure ratings (Not available with X or Z option) M Gold electrical contacts for extremely low current applications R 72" Electrical free leads S Stainless steel diaphragm V 1/4 NT male port X UL and CSA Approval and CE Mark (Not available with J option) Z Mounting bracket kit (Not available with J option) Special (Consult representative or factory) Non-catalog adjustable range and/or set point, deadband and proof pressure roof ressure Ordering rocedure Example Weather roof (NEMA 4X and 13) When factory presetting is desired, stipulate set point, increasing or decreasing Insert available option number or letter designation as required When a selectable DB is desired, stipulate DB within allowed range CC3_ Series (specify)

37 Field Adjustable 1 to 216 psig Series 131 Envelope Dimensions ½ ½ ¼ FORM "C" (SDT) FORM "CC" (DDT) (X OTION) BLK YEL NC2 C2 VIO NO2 (X OTION) Basic rinciples of Design Neo-Dyn Industry Drive Valencia, CA tel: fax: AER0935_23 11/14 Specifications and dimensions subject to change.

38 Neo-Dyn Neo-Dyn Series 231 ressure Switch/Internal Compact, adjustable pressure switch for high pressure hydraulic process applications. Using our efficient Nega-Rate Belleville disc spring, we offer superior set point stability and vibration resistance. Operating ressure Data Adjustable Range Adjustable Set oint Range Number Increasing * * * * * * Decreasing 250 to to to to to to 9000 All values given in psig unless otherwise noted. * Add selected deadband to decreasing pressure range. Standard Specifications Electrical Listings Snap action electrical switch recognized by Underwriters Laboratories, Inc. and CSA International Electrical Connection 1/2 NT male conduit connection with VC insulated 18AWG, 18 long leads ressure Connection 1/4 NT Female 1/2 NT Male (N/A Range 8) Temperature Range* Ambient: -40 F to +180 F (-40 C to +82 C) Media: - 40 F to +300 F (-40 C to +149 C) * Temperature limits change with O-Ring selection Internal, slotted adjustment nut Shipping Weight Approximately 20 ounces Order Option D Deadband (approximate) Maximum Recommended System ressure ,500 Ordering Sequence Select desired option for each category OTIONS 1 Aluminum port and piston, teflon seal, and Buna-N O-Ring (not available for Range 8) stainless steel port and piston, teflon seal, and Buna-N O-Ring psig dec. to 800 psig inc. (17.3 bar dec. to 55.1 bar inc.) psig dec. to 1190 psig inc. (41.4 bar dec. to 82.0 bar inc.) psig dec. to 3000 psig inc. (48.3 bar dec. to 207 bar inc.) psig dec. to 4850 psig inc. (165 bar dec. to 334 bar inc.) psig dec. to 7000 psig inc. (283 bar dec. to 483 bar inc.) psig dec. to 10,000 psig inc. (379 bar dec. to 689 bar inc.) C 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; CC 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; 3 Meets or exceeds the requirements of NEMA Type 3, 3R, 3S, 4, 4X and 13 A Epoxy paint exterior extra protection for severe environments B Viton O-Ring C ER O-Ring D SIL approval and marking, per IEC61508 (includes FMEA report) I 3/4 NT conduit box with terminal strip J Annealed stainless steel port screws for H 2 S environments Consult factory for reduced system and proof pressure ratings (Not available with X option) M Gold electrical contacts for extremely low current applications R 72" Electrical free leads Z Mounting bracket kit X CE Mark Special (Consult representative or factory) Non-catalog adjustable range and/or set point, deadband and proof pressure roof ressure ,000 Ordering rocedure Example Weather roof (NEMA 4X and 13) When factory presetting is desired, stipulate set point, increasing or decreasing Insert available option number or letter designation as required CC3_ Series (specify)

39 Field Adjustable 250 to 7000 psig Series 231 Envelope Dimensions FORM "C" (SDT) FORM "CC" (DDT) (X-OTION) BLK NC2 YEL C2 VIO NO2 (X-OTION) Basic rinciples of Design Neo-Dyn Industry Drive Valencia, CA tel: fax: AER0935_48 7/13 Specifications and dimensions subject to change.

40 Neo-Dyn Neo-Dyn Series 105/105 ressure Switch/Miniature Tamper roof All purpose miniature tamper proof switch, extremely light weight and durable construction. Has efficient Nega-Rate Belleville disc spring sensing mechanism. Small size improves vibration and shock resistance. Operating ressure Data Series (5 wetted material) 105 (5 wetted material) 105 (5 wetted material) 105 All values given in psig. Standard Specifications Deadband (Differential) The deadband can be selected anywhere from the minimum indicated to a maximum of 45% of the set point. Electrical Connection VC insulated 18 AWG leads 18" long ressure Connection 1/4 NT Male Temperature Range* Ambient: - 40 F to +180 F (-40 C to +82 C) Media: - 40 F to +300 F (-40 C to +149 C) *Temperature limits change with O-Ring selection Shipping Weight Approximately 3 ounces Fixed Set oint Range Increasing Decreasing 5 to to to to to to to to to to 1700 * Whichever is greater Deadband (minimum) 3 or 10% * 5 or 15% * 25% 15% 15% Maximum Recommended System ressure Ordering Sequence Select desired option for each category OTIONS 1 Aluminum port, polyimide diaphragm and Buna-N O-Ring stainless steel port, polyimide diaphragm and Buna-N O-Ring stainless steel port and diaphragm heliarc welded (N/A on 105) C 2 and 5 7 amp at 125/250 VAC; 7 amp resistive, 4 amp inductive at 28 VDC CC 2 only 7 amp at 125/250 VAC; 7 amp resistive, 4 amp inductive at 28 VDC 2 Meets or exceeds requirements of NEMA Type 1 and 2 5 Hermetically sealed electrical assembly [Suitable for all Division 2 hazardous locations] ( 1 and 4 only) B Viton O-Ring C ER O-Ring M Gold electrical contacts for extremely low current applications R 72" Electrical free leads Special (Consult representative or factory) ressure port per SAE AS4395E04 Electrical connection per MS SL-3 Non-catalog set point, deadband and/or proof pressure Media temperature capability from -65 F to +400 F roof ressure Ordering rocedure Example General urpose (NEMA 1 and 2) Specify set point, increasing or decreasing Specify deadband if pertinent and if not, specify as open Specify system pressure Specify proof pressure Specify media Insert available option number or letter designation as required 105 1CC 2 _-_ Series Customer identification number (numerically assigned by factory)

41 Factory Set/Tamper roof Miniature 2 to 2000 psig Series 105/105 Envelope Dimensions ressure ort ¹ ₄ NT Free Leads 18 AWG 18" Long 1.00 (typ.) ( 2) 2.99 ( 5) FORM "C" (SDT) FORM "CC" (DDT) BLK NC2 YEL C2 VIO NO2 Basic rinciples of Design Diaphragm Minimum Bearing oints Snap Action Electrical Element ressure ort O-Ring Negative Rate Belleville Disc Spring ressure late Neo-Dyn Industry Drive Valencia, CA tel: fax: AER0935_10 6/12 Specifications and dimensions subject to change.

42 Neo-Dyn Neo-Dyn Series 115/115 ressure Switch/Tamper roof Compact, versatile pressure switch with built to order set points. This easy to install switch features the efficient Nega-Rate Belleville disc spring for the set and forget application. Operating ressure Data Series All values given in psig. Standard Specifications Deadband (Differential) The deadband can be selected anywhere from.5 psig or 8% (whichever is greater) to 45% of the set point Electrical Snap action electrical switch recognized by Underwriters Laboratories, Inc. and CSA International Electrical Connection 1/2 NT male conduit connection with VC insulated 18 AWG leads 18" long ressure Connection 1/4 NT Male Temperature Range* Ambient: - 40 F to +180 F (-40 C to +82 C) Media: - 40 F to +300 F (-40 C to +149 C) *Temperature limits change with O-Ring selection Shipping Weight Approximately 6 ounces Order Option D Fixed Set oint Range Increasing Decreasing 2 to to to to 220 Maximum Recommended System ressure Up to 600 Up to 600 Ordering Sequence Select desired option for each category OTIONS Set oints 115 between 1.5 psig dec. and 70 psig inc. (.10 bar dec. to 4.8 bar inc.) 115 between 65 psig dec. and 250 psig inc. (4.5 bar dec. to 17 bar inc.) 1 Aluminum port, Teflon coated polyimide diaphragm and Buna-N O-Ring Stainless steel port, Teflon coated polyimide diaphragm and Buna-N O-Ring C 5 amp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC CC 5 amp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC 3 Meets or exceeds the requirements of NEMA Type 3, 3R, 3S, 4, 4X and 13 A Epoxy paint exterior extra protection for severe environments B Viton O-Ring C ER O-Ring D SIL approval and marking, per IEC61508 (includes FMEA report) M Gold electrical contacts for extremely low current applications R 72" Electrical free leads S Stainless steel diaphragm (115, 4 only. Not available on 115) W Stainless steel screws exterior (automatically furnished with Option A and 4) Special (Consult representative or factory) ressure port per SAE AS4355E04 Electrical connection per MS SL-3 Non-catalog set point, deadband and/or proof pressure 11 amp 125/250 VAC electrical rating Media temperature capability from -65 F to +350 F roof ressure Up to 1000 Up to 1000 Weather roof (NEMA 4 and 13) Ordering rocedure Specify set point, increasing or decreasing Specify deadband if pertinent and if not, specify as open Specify system pressure Specify proof pressure Specify media Insert available option as required Example 115 1CC 3 _-_ Series Customer Identification Number (numerically assigned by factory)

43 Factory Set/Tamper roof 1.5 to 250 psig Series 115/115 Envelope Dimensions Free Leads 18 AWG 18" Long 1.92 Dia. ressure ort ¹ ₄ NT Conduit Connection ¹ ₂ NT.87 (typ.) 1.75 (typ.) FORM "C" (SDT) FORM "CC" (DDT) BLK NC2 YEL C2 VIO NO2 Basic rinciples of Design O-Ring Minimum Bearing oints Negative Rate Belleville Disc Spring Snap Action Electrical Element ressure ort Diaphragm ressure late Neo-Dyn Industry Drive Valencia, CA tel: fax: AER0935_14 7/13 Specifications and dimensions subject to change.

44 Neo-Dyn Neo-Dyn Series 125 ressure Switch/Tamper roof Designed for high pressure pneumatic or low impulse hydraulic applications requiring a narrow deadband. Has diaphragm sensor with efficient Nega-Rate Belleville disc spring for excellent accuracy and repeatability. Operating ressure Data Series 125 All values given in psig. Increasing 40 to 3050 Fixed Set oint Range Decreasing 20 to 2800 Maximum Recommended System ressure 5000 roof ressure 7500 Standard Specifications Deadband (Differential) The deadband can be selected anywhere from 20 psig (1.38 bar) or 8% (whichever is greater) to 45% of the set point Electrical Snap action electrical switch recognized by Underwriters Laboratories, Inc. and CSA International Electrical Connection 1/2 NT male conduit connection with VC insulated 18 AWG leads 18" long ressure Connection 1/4 NT Female Temperature Range* Ambient: - 40 F to +180 F (-40 C to +82 C) Media: - 40 F to +300 F (-40 C to +149 C) *Temperature limits change with O-Ring selection Shipping Weight Approximately 10 ounces Ordering Sequence Select desired option for each category OTIONS Set oints 125 between 20 psig dec. and 3050 psig inc. (1.4 bar dec. and 210 bar inc.) 1 Aluminum port, Teflon coated polyimide diaphragm and Buna-N O-Ring Stainless steel port, Teflon coated polyimide diaphragm and Buna-N O-Ring C 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; 5 amp resistive at 125 VDC CC 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; 5 amp resistive at 125 VDC 3 Meets or exceeds the requirements of NEMA Type 3, 3R, 3S, 4, 4X and 13 A Epoxy paint exterior extra protection for severe environments B Viton O-Ring C ER O-Ring D SIL approval and marking, per IEC61508 (includes FMEA report) M Gold electrical contacts for extremely low current applications R 72" Electrical free leads W Stainless steel screws exterior X CSA approved and CE Mark Special (Consult representative or factory) ressure port per SAE AS4355E04 Non-catalog set point, deadband and/or proof pressure Media temperature capability from -65 F to +350 F Order Option D Weather roof (NEMA 4 and 13) Ordering rocedure Specify set point, increasing or decreasing Specify deadband if pertinent Specify media Insert available option number or letter as required Example 125 1CC 3 _-_ Series Customer Identification Number (numerically assigned by factory)

45 Factory Set/Tamper roof 20 to 3050 psig Series 125 Envelope Dimensions ressure ort ¹ v ¼ NT.209 Dia. Mtg. Holes (2 places) Conduit Connection ¹ x ½ NT Free Leads 18" Long 18 AWG SQ FORM "C" (SDT) FORM "CC" (DDT) (X OTION) BLK NC2 YEL C2 VIO NO2 (X OTION) Basic rinciples of Design Minimum Bearing oints Snap Action Electrical Element Diaphragm O-Ring Seal Negative Rate Belleville Disc Spring Helical Spring Neo-Dyn Industry Drive Valencia, CA tel: fax: AER0935_19 7/13 Specifications and dimensions subject to change.

46 Neo-Dyn Neo-Dyn Series 225 ressure Switch/Tamper roof A sealed piston sensor with a efficient Nega-Rate Belleville disc spring makes this switch well suited for high impulse hydraulic applications. Operating ressure Data Series Fixed Set oint Range Increasing 45 to to to 7500 Decreasing 15 to to to 6750 All values given in psig. *Diminished safety factor equal to approximately 2:1 **Diminished safety factor equal to approximately 1.3:1 Deadband (minimums) 30 or 10% 160 or 10% 10% Maximum Recommended System ressure Hydraulic ,000* neumatic roof ressure Hydraulic ,000** neumatic Standard Specifications Deadband (Differential) The deadband can be selected anywhere from the minimum tabulated to a maximum of 45% of the set point Electrical Snap action electrical switch recognized by Underwriters Laboratories, Inc. and CSA International Electrical Connection 1/2 NT male conduit connection with VC insulated 18 AWG, 18" long leads ressure Connection 1/4 NT Female Temperature Range* Ambient: - 40 F to +180 F (-40 C to +82 C) Media: - 40 F to +300 F (-40 C to +149 C) *Temperature limits change with O-Ring selection Shipping Weight Approximately 10 ounces Order Option D Ordering Sequence Select desired option for each category OTIONS Set oints 225 between 15 psig dec. and 450 psig inc. (1.0 bar dec. and 31 bar inc.) 225 between 250 psig dec. and 3000 psig inc. (17 bar dec. and 207 bar inc.) 225 between 2701 psig dec. and 7500 psig inc. (186 bar dec. and 517 bar inc.) 1 Aluminum port and piston, Teflon seal and Buna-N O-Ring C 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; CC 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; 3 Meets or exceeds the requirements of NEMA Type 3, 3R, 3S, 4, 4X and 13 A Epoxy paint exterior extra protection for severe environments B Viton O-Ring C ER O-Ring D SIL approval and marking, per IEC61508 (includes FMEA report) M Gold electrical contacts for extremely low current applications R 72" Electrical free leads W Stainless steel screws exterior X CSA Certified and CE Mark Special (Consult representative or factory) ressure port per MS33649E4 Non-catalog set point, deadband and/or proof pressure Stainless steel Aminco port with 9/16" - 18 UNF-3B THD Media temperature capability from -65 F to +350 F Weather roof (NEMA 4 and 13) Ordering rocedure Specify set point, increasing or decreasing Specify deadband if pertinent and if not, specify as open Specify media Insert available option number or letter as required Example 225 1CC 3 _-_ Series Customer Identification Number (numerically assigned by factory)

47 Field Adjustable 15 to 7500 psig Series 225 Envelope Dimensions ressure ort ¹ v ¼ NT.209 Dia. Mtg. Holes (2 places) Conduit Connection ¹ x ½ NT Free Leads 18" Long 18 AWG (typ.) FORM "C" (SDT) FORM "CC" (DDT) (X-Option) BLK NC2 YEL C2 OVIO NO2 (X-Option) Basic rinciples of Design iston O-Ring Minimum Bearing oints Snap Action Electrical Element ressure ort O-Ring Negative Rate Belleville Disc Spring Helical Spring Neo-Dyn Industry Drive Valencia, CA tel: fax: AER0935_46 7/13 Specifications and dimensions subject to change.

48 Neo-Dyn Neo-Dyn Series 100 ressure Switch/Internal Versatile Nega-Rate Belleville spring pressure switch for use in division 2 hazardous areas. Applications include pneumatic and low impulse hydraulics up to 3000 psig system pressures. Various wetted material selections make this switch ideal for any type of process application. Operating ressure Data Adjustable Range Number All values given in psig. Standard Specifications Electrical Connection 3/4 NT female conduit connection with terminal block and ground screw ressure Connection 1-1/4 NT Female 4, 5, 7 and 9 1/2 NT Female *Temperature Range (Ambient) 11 amp T4-40 F to +165 F (-40 C to +74 C) 5 amp T5-40 F to +180 F (-40 C to +82 C) 5 amp T6-40 F to +172 F (-40 C to +78 C) M Option: 1 amp T6-40 F to +180 F (-40 C to +82 C) Media: - 40 F to +300 F (-40 C to +149 C) Media temperature limits change with O-Ring selection. Concealed wrench flat adjustment with range scale Shipping Weight Approximately 3 pounds Order Option D Adjustable Set oint Range Increasing 5 to to to to to to 2800 Decreasing 2.3 to to to to to to 2675 Deadband (approximate) Maximum System ressure Ordering Sequence Select desired option for each category OTIONS 1 Aluminum port, Teflon coated polyimide diaphragm, Buna-N O-Ring stainless steel port, Teflon coated polyimide diaphragm, Buna-N O-Ring stainless steel port and diaphragm, heliarc welded 7 Hastelloy C port and diaphragm, heliarc welded (Except Range 1) 9 Monel port and inconel diaphragm, heliarc welded (Except Range 1) psig dec. to 75 psig inc. (0.2 bar dec. to 5.2 bar inc.) 2 9 psig dec. to 150 psig inc. (0.6 bar dec. to 10.3 bar inc.) 4 36 psig dec. to 300 psig inc. (2.5 bar dec. to 20.7 bar inc.) psig dec. to 600 psig inc. (6.9 bar dec. to 41.4 bar inc.) psig dec. to 1500 psig inc. (30.3 bar dec. to bar inc.) psig dec. to 2800 psig inc. (46.5 bar dec. to bar inc.) C 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC CC 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC roof ressure Explosion proof, hermetically-sealed electrical assembly for Division 2 Hazardous Locations, Underwriters Laboratories, Inc. listed (File E56677), CSA International certified (File LR34146) A Epoxy paint exterior extra protection for severe environments B Viton O-Ring C ER O-Ring D SIL approval and marking, per IEC61508 (includes FMEA report) B 7/16" - 20 SAE Female ort (wetted material 1 only) F Fire fuse for fire-tested equipment (wetted material 4 & 5 only) M Gold electrical contacts for extremely low current applications (1 Amp at 125 VAC; 1 Amp Res, 0.5 Amp Ind. at 28 VDC) O Oxygen clean S Stainless steel diaphragm (wetted material 4 only) W Stainless steel screws exterior (Standard with s 4, 5, 7 and 9) Y 2" NT Female port for viscous medias. ort Material is carbon steel ( 3 ) Order as 1003xxxxY Ordering rocedure Example Explosion roof Division 2 (NEMA 4X, 7, 9 and 13) When factory presetting is desired, stipulate set point, increasing or decreasing Insert available option number or letter designation as required C 5_ Series

49 Field Adjustable 2.3 to 2800 psig Series 100 Envelope Dimensions Max.11 Range 1 Only X Max ³ ₄ NT Conduit Connection X.265 Dia. Mounting Holes ressure ort ¹ ₄ NT 1 ¹ ₂ NT s 4, 5, 7 and 9.19 Range 1 Only Basic rinciples of Design Hermetically Sealed All Stainless Steel Electrical Element Motion Transfer Arm Actuator ressure late ³ ₄ Conduit Connection Terminal Block Negative Rate Belleville Disc Spring Neo-Dyn Industry Drive Valencia, CA tel: fax: AER0935_2 7/13 Specifications and dimensions subject to change.

50 Neo-Dyn Neo-Dyn Series 100 ressure Switch/Internal Versatile Nega-Rate Belleville disc spring pressure switch for use in hazardous areas. Applications include pneumatic and low impulse hydraulics up to 3000 psig system pressures. Various wetted material selections make this switch ideal for your specific requirement. Operating ressure Data Adjustable Range Number Adjustable Set oint Range Increasing 5 to to to to to to 2800 Decreasing 2 to 72 9 to to to to to 2675 Deadband (approximate) Maximum Recommended System ressure roof ressure All values given in psig. Standard Specifications Electrical Snap action electrical switch listed by Underwriters Laboratories, Inc., SIRA and CSA International Electrical Connection 3/4 NT female conduit connection with terminal block ressure Connection 1 1/4 NT Female 4, 5, 7 and 9 1/2 NT Female Temperature Range Ambient: - 40 F to +180 F (-40 C to +82 C) Media: - 40 F to +300 F (-40 C to +149 C) Tool free internal adjustment with range scale Shipping Weight Approximately 6 pounds Order Option D Explosion roof (NEMA 4X, 7, 9 and 13) Ordering Sequence Select desired option for each category OTIONS 1 Aluminum port, Teflon coated polyimide diaphragm, Buna-N O-Ring stainless steel port, Teflon coated polyimide diaphragm, Buna-N O-Ring stainless steel port and diaphragm, heliarc welded 7 Hastelloy C port and diaphragm, heliarc welded (Except Range 1) 9 Monel port and inconel diaphragm, heliarc welded (Except Range 1) 1 2 psig dec. to 75 psig inc. (0.2 bar dec. to 5.2 bar inc.) 2 9 psig dec. to 150 psig inc. (0.6 bar dec. to 10.3 bar inc.) 4 36 psig dec. to 300 psig inc. (2.5 bar dec. to 20.7 bar inc.) psig dec. to 600 psig inc. (6.9 bar dec. to 41.4 bar inc.) psig dec. to 1500 psig inc. (30.3 bar dec. to bar inc.) psig dec. to 2800 psig inc. (46.5 bar dec. to bar inc.) C 15 amp 125, 250 or 480 VAC; 2 amp 600 VAC; 1/8 hp 125 VAC; 1/4 hp 250 VAC;.5 amp resistive,.04 amp inductive 125 VDC CC 11 amp and 1/4 hp 125 or 250 VAC; 5 amp resistive, 3 amp inductive 28 VDC;.5 amp resistive 125 VDC Z 15 amp 125, 250 or 480 VAC; 1/4 hp 125 VAC; 1/2 hp 250 VAC; 1 amp resistive,.5 amp inductive 125 VDC 7 Explosion proof, CE MARK, Underwriters Laboratories, Inc. listed (File E56677), CSA International certified (File LR34146), and SIRA approved (File 10ATEX1018X) for Division 1 and 2; Class I, Groups C and D; Class II, Groups E, F and G; Ex d IIB Hazardous Locations; NEMA type 7 and 9, and I65. A Epoxy paint exterior extra protection for severe environments B Viton O-Ring C ER O-Ring D SIL approval and marking, per IEC61508 (includes FMEA report) E 7/16-20 SAE Female ort (wetted material 1 only) F Fire fuse for fire-tested equipment (wetted material 4 & 5 only) M Gold electrical contacts for extremely low current applications (1 Amp at 125 VAC; 1 Amp Res, 0.5 Amp Ind. at 28 VDC) S Stainless steel diaphragm (wetted material 4 only) W Stainless steel screws exterior (Standard with s 4, 5, 7 and 9) Ordering rocedure When factory presetting is desired, stipulate set point, increasing or decreasing Insert available option number or letter designation as required Example CC7_ Series

51 Field Adjustable 2.3 to 2800 psig Series 100 Envelope Dimensions Conduit Connection ³ ₄ NT Female (2 places) ¹ ₄" Dia. Mounting Holes (2 places) (Range 1 only) ressure ort ¹ ₄ NT (wetted material 1) ¹ ₂ NT (wetted material 4, 5, 7, 9) FORM "Z" GREEN SCREW Basic rinciples of Design Snap Action Electrical Element Terminal Block Actuator Diaphragm Minimum O-Ring Bearing oints WARNING ressure late Negative Rate Belleville Disc Spring Neo-Dyn Industry Drive Valencia, CA tel: fax: AER0935_3 7/13 Specifications and dimensions subject to change.

52 Neo-Dyn Neo-Dyn Series 100 ressure Switch/Internal Versatile Nega-Rate Belleville disc spring pressure switch for use in hazardous areas. Applications include pneumatic and low impulse hydraulics up to 3000 psig system pressures. Various wetted material selections make this switch ideal for your specific requirement. Operating ressure Data Adjustable Range Number Adjustable Set oint Range Increasing 5 to to to to to to 2800 Decreasing 2 to 72 9 to to to to to 2675 Deadband (approximate) Maximum Recommended System ressure roof ressure All values given in psig. Standard Specifications Electrical Snap action electrical switch listed by Underwriters Laboratories, Inc., SIRA and CSA International Electrical Connection 3/4 NT female conduit connection with terminal block ressure Connection 1 1/4 NT Female 4, 5, 7 and 9 1/2 NT Female Temperature Range Ambient: - 40 F to +180 F (-40 C to +82 C) Media: - 40 F to +300 F (-40 C to +149 C) Tool free internal adjustment with range scale Shipping Weight Approximately 6 pounds Order Option D Explosion roof (NEMA 4X, 7, 9 and 13) Ordering Sequence Select desired option for each category OTIONS 1 Aluminum port, Teflon coated polyimide diaphragm, Buna-N O-Ring stainless steel port, Teflon coated polyimide diaphragm, Buna-N O-Ring stainless steel port and diaphragm, heliarc welded 7 Hastelloy C port and diaphragm, heliarc welded (Except Range 1) 9 Monel port and inconel diaphragm, heliarc welded (Except Range 1) 1 2 psig dec. to 75 psig inc. (0.2 bar dec. to 5.2 bar inc.) 2 9 psig dec. to 150 psig inc. (0.6 bar dec. to 10.3 bar inc.) 4 36 psig dec. to 300 psig inc. (2.5 bar dec. to 20.7 bar inc.) psig dec. to 600 psig inc. (6.9 bar dec. to 41.4 bar inc.) psig dec. to 1500 psig inc. (30.3 bar dec. to bar inc.) psig dec. to 2800 psig inc. (46.5 bar dec. to bar inc.) C 15 amp 125, 250 or 480 VAC; 2 amp 600 VAC; 1/8 hp 125 VAC; 1/4 hp 250 VAC;.5 amp resistive,.04 amp inductive 125 VDC CC 11 amp and 1/4 hp 125 or 250 VAC; 5 amp resistive, 3 amp inductive 28 VDC;.5 amp resistive 125 VDC Z 15 amp 125, 250 or 480 VAC; 1/4 hp 125 VAC; 1/2 hp 250 VAC; 1 amp resistive,.5 amp inductive 125 VDC 7 Explosion proof, CE MARK, Underwriters Laboratories, Inc. listed (File E56677), CSA International certified (File LR34146), and SIRA approved (File 10ATEX1018X) for Division 1 and 2; Class I, Groups C and D; Class II, Groups E, F and G; Ex d IIB Hazardous Locations; NEMA type 7 and 9, and I65. A Epoxy paint exterior extra protection for severe environments B Viton O-Ring C ER O-Ring D SIL approval and marking, per IEC61508 (includes FMEA report) E 7/16-20 SAE Female ort (wetted material 1 only) F Fire fuse for fire-tested equipment (wetted material 4 & 5 only) M Gold electrical contacts for extremely low current applications (1 Amp at 125 VAC; 1 Amp Res, 0.5 Amp Ind. at 28 VDC) S Stainless steel diaphragm (wetted material 4 only) W Stainless steel screws exterior (Standard with s 4, 5, 7 and 9) Ordering rocedure When factory presetting is desired, stipulate set point, increasing or decreasing Insert available option number or letter designation as required Example CC7_ Series

53 Field Adjustable 2.3 to 2800 psig Series 100 Envelope Dimensions Conduit Connection ³ ₄ NT Female (2 places) ¹ ₄" Dia. Mounting Holes (2 places) (Range 1 only) ressure ort ¹ ₄ NT (wetted material 1) ¹ ₂ NT (wetted material 4, 5, 7, 9) FORM "Z" GREEN SCREW Basic rinciples of Design Snap Action Electrical Element Terminal Block Actuator Diaphragm Minimum O-Ring Bearing oints WARNING ressure late Negative Rate Belleville Disc Spring Neo-Dyn Industry Drive Valencia, CA tel: fax: AER0935_3 7/13 Specifications and dimensions subject to change.

54 Neo-Dyn Neo-Dyn Series 110 Sensitive Nega-Rate Belleville spring adjustable pressure switch for low pressure applications. Unit has been designed for Division 2 explosion proof environments and is weather proof, making it suitable for all of your Division 2 applications. Operating ressure Data Adjustable Range Number 2 4 Standard Specifications Adjustable Set oint Range Increasing 10" H 2 0 to 100" H to 15 Decreasing 7" H 2 0 to 97" H to All values given in psig (except as noted). *Deadband increases to.4 psi (approx.) in CC5 configuration. Electrical Snap action electrical switch assembly listed by Underwriters Laboratories, Inc., FM Approval and CSA International Electrical Connection 3/4 NT female conduit connection with terminal block ressure Connection 1 1/4 NT Female 4 1/2 NT Female Temperature Range Ambient: 11 amp T4-40 F to +165 F (-40 C to +74 C) 5 amp T5-40 F to +180 F (-40 C to +82 C) 5 amp T6-40 F to +172 F (-40 C to +78 C) M Option: 1 amp T6-40 F to +180 F (-40 C to +82 C) Media: - 40 F to +300 F (-40 C to +149 C) Concealed wrench flat adjustment with range scale Shipping Weight Approximately 3 pounds ressure Switch/Internal Deadband (approximate) 3" H * Maximum Recommended System ressure Ordering Sequence Select desired option for each category OTIONS 1 Aluminum port, Teflon coated polyimide diaphragm and Buna-N O-Ring stainless steel port, Teflon coated polyimide diaphragm and Buna-N O-Ring 2 7" H 2 0 dec. to 100" H 2 0 inc. (17 millibar dec. to 249 millibar inc.) psig dec. to 15 psig inc. (0.2 bar dec. to 1.0 bar inc.) C 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; CC 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; roof ressure 5 Explosion proof, hermetically-sealed electrical assembly for Division 2 Hazardous Locations, Underwriters Laboratories, Inc. listed (File E56677), CSA International certified (File LR34146) A Epoxy paint exterior extra protection for severe environments B Viton O-Ring C ER O-Ring D SIL approval and marking, per IEC61508 (includes FMEA report) F Fire fuse for fire-tested equipment ( 4 only; Not Available with G) G 1/2 NT male port ( 4 only) M Gold electrical contacts for extremely low current applications S Stainless steel diaphragm ( 4 only) W Stainless steel screws exterior (Standard with 4) Special (Consult representative or factory) Non-catalog adjustable range and/or set point, deadband and proof pressure Chemical seals installed Order Option D Ordering rocedure Example Explosion roof (Division 2) When factory presetting is desired, stipulate set point, increasing or decreasing Insert available option number or letter designation as required C 5_ Series

55 Field Adjustable 7" H 2 O to 15 psig Series 110 Envelope Dimensions WM WM WM WM X Max ³ ₄ NT Conduit Connection Dia. Mtg. Holes (2 places) ressure ort ¹ ₄ NT 1 ¹ ₂ NT 4 aá~k.38 Basic rinciples of Design Snap Action Electrical All Stainless Element Steel Construction Electrical Assembly Actuator Diaphragm O-Ring Glass to Metal Sealed Header Motion Transfer Arm ressure ort ressure late Negative Rate Belleville Disc Spring Neo-Dyn Industry Drive Valencia, CA tel: fax: AER0935_12 7/13 Specifications and dimensions subject to change.

56 Neo-Dyn Neo-Dyn Series 110 ressure Switch/Internal Sensitive Nega-Rate Belleville spring adjustable pressure switch for low pressure applications. Operating ressure Data Adjustable Range Number 2 4 Adjustable Set oint Range Increasing 10" H 2 0 to 100" H to 15 Decreasing 7" H 2 0 to 97" H to All values given in psig. *Deadband increases to.4 psi (approx.) in CC6 configuration. Deadband (approximate) 3" H * Maximum Recommended System ressure roof ressure Standard Specifications Electrical Snap action electrical switch assemblies, art Numbers & (Form C) and & (Form CC), are listed by Underwriters Laboratories, Inc., FM Approvals, CSA International and NCC (INMETRO). See the miscellaneous option N for additional listings. Electrical Connection 1/2 NT male conduit connection with VC insulated 18 AWG, 18" long leads ressure Connection 1 1/4 NT Female 4 1/2 NT Female Temperature Range* Ambient: - 40 F to +180 F (-40 C to +82 C) Media: - 40 F to +300 F (-40 C to +149 C) *Temperature limits change with O-Ring selection. See Electrical Assembly specification sheet for Temperature Class Ratings. Concealed wrench flat adjustment with range scale Shipping Weight Approximately 3 pounds Ordering Sequence Select desired option for each category OTIONS 1 Aluminum port, Teflon coated polyimide diaphragm and Buna-N O-Ring stainless steel port, Teflon coated polyimide diaphragm and Buna-N O-Ring 2 7" H 2 0 dec. to 100" H 2 0 inc. (17 millibar dec. to 249 millibar inc.) psig dec. to 15 psig inc. (0.2 bar dec. to 1.0 bar inc.) C 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive 28 VDC; CC 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive 28 VDC; 6 Includes an explosion proof, hermetically-sealed electrical assembly. EX d IIC. Division 1 and 2, Class I, Groups A, B, C, and D; Class II, Groups E, F, and G. NEMA 4X, 7, and 9; I66. Leads are factory sealed and ressure Switches are Dual Seal Certified. A Epoxy paint exterior extra protection for severe environments B Viton O-Ring C ER O-Ring D SIL approval and marking, per IEC61508 (includes FMEA report) F Fire fuse for fire-tested equipment (wetted material 4 only: not available with option G) G 1/2 NT male port (wetted material 4 only) I 3/4 NT conduit box with terminal strip (Groups C & D only, not available with N option) M Gold electrical contacts for extremely low current applications (1 Amp at 125 VAC; 1 Amp Res, 0.5 Amp Ind. at 28 VDC) N ATEX and IECEx with CE Mark R 72" Electrical free leads S Stainless steel diaphragm (wetted material 4 only) W Stainless steel screws exterior (standard with wetted m aterial 4) Special (Consult representative or factory) Non-catalog adjustable range and/or set point, deadband and proof pressure Chemical seals installed Order Option D Ordering rocedure Example Explosion roof Hermetically Sealed (NEMA 4X, 7, 9 and 13) When factory presetting is desired, stipulate set point, increasing or decreasing Insert available option number or letter designation as required C 6_ Series

57 Field Adjustable 7" H 2 O to 15 psig Series 110 Envelope Dimensions 1.45 A 2.72 C B ressure ort WETTED MATERIALS A B ¹ ₄ NT ¹ ₂ NT C Conduit Connection ¹ ₂ NT.265 Dia. Mtg. Holes (2 places) Dia FORM "C" (SDT) FORM "CC" (DDT) BLK NC2 YEL C2 VIO NO2 Basic rinciples of Design Snap Action Electrical All Stainless Element Steel Construction Electrical Assembly Actuator Diaphragm O-Ring Glass to Metal Sealed Header Motion Transfer Arm ressure ort ressure late Negative Rate Belleville Disc Spring Neo-Dyn Industry Drive Valencia, CA tel: fax: AER0935_13 7/13 Specifications and dimensions subject to change.

58 Neo-Dyn Neo-Dyn Series 1428 Ultra Low Vacuum/ressure Switch Ultra low pressure and vacuum to pressure crossover switch. Unique construction using efficient Nega-Rate Belleville disc spring for stable set points and high proof pressure. Explosion proof enclosure and wide range of wetted materials makes this switch especially well suited for hazardous or corrosive atmospheres. Operating ressure Data Adjustable Range Number Adjustable Set oint Range Increasing Deadband* (approximate) Maximum Recommended System ressure roof ressure 0 1" to 10" H 2 O.75" H 2 O 30" H 2 O Vacuum to 30" H 2 O ressure 30" H 2 O Vacuum to +5 psig 1 2 Standard Specifications Electrical Snap action electrical switch assemblies, art Numbers & (Form C) and & (Form CC), are listed by Underwriters Laboratories, Inc., FM Approvals, CSA International and NCC (INMETRO). See the miscellaneous option N for additional listings. Electrical Connection 1/2 NT male conduit connection with VC insulated 18 AWG, 18 long leads ressure Connection 1/2 NT Female Temperature Range* Ambient: - 40 F to +180 F (-40 C to +82 C) Media: - 50 F to +250 F (-46 C to +121 C) *Temperature limits change with O-Ring selection. See Electrical Assembly specification sheet for Temperature Class Ratings. Concealed wrench flat adjustment with range scale Shipping Weight Approximately 3.5 pounds 2" to 40" H 2 O 0" to 40" H 2 O Vacuum to 0" to 40" H 2 O ressure *Deadband 50% wider with "CC" (DDT) s. Order Option D 1" H 2 O 1" H 2 O 30" H 2 O Vacuum to +5 psig Full Vacuum to +15 psig Ordering Sequence Select desired option for each category 30" H 2 O Vacuum to +15 psig Full Vacuum to 100 psig OTIONS 0.25" H2O (.62 mbar) dec. to 10" (24.9 mbar) H2O inc. 1 1" H2O (2.49 mbar) dec. to 40" (99.6 mbar) H2O inc. 2 40" H2O (99.6 mbar) inc. vac. to 40" (99.6 mbar) H2O inc. pressure C 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; CC 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; 6 Includes an explosion proof, hermetically-sealed electrical assembly. EX d IIC. Division 1 and 2, Class I, Groups A, B, C, and D; Class II, Groups E, F, and G. NEMA 4X, 7, and 9; I66. Leads are factory sealed and ressure Switches are Dual Seal Certified. A Epoxy paint exterior extra protection for severe environments D SIL approval and marking, per IEC61508 (includes FMEA report) I 3/4 NT conduit box with terminal strip (Groups C & D only, not available with N option) M Gold electrical contacts for extremely low current applications (1 Amp at 125 VAC; 1 Amp Res, 0.5 Amp Ind. at 28 VDC) N ATEX and IECEx R 72" Electrical free leads ort Material Stainless Steel 7 Hastelloy C Diaphragm 1 olyimide Stainless Steel 6 Tantalum 7 Hastelloy C O-Rings 2 Kalrez 3 Viton 5 ER 8 Buna-N Special (Consult representative or factory) Non-catalog adjustable range and/or set point, deadband and proof pressure Media temperature capabilities from -65 F to +400 F Explosion roof Hermetically Sealed (NEMA 4X, 7, 9 and 13) Ordering rocedure When factory presetting is desired, stipulate set point, increasing or decreasing Insert available option number or letter designation as required Example CC6 _ 463 Series ort Material Diaphragm O-Rings

59 Field Adjustable 40" H 2 O vac. to 40" H 2 O Series 142 Envelope Dimensions Free Leads 18 AWG 18" Long Dia Conduit Connection ¹ ₂ NT.265 Dia. Mtg. Holes (2 places) 3.50 Reference ort ¹ ₄ NT DO NOT LUG Random Radial Location ressure ort ¹ ₂ NT FORM "C" (SDT) FORM "CC" (DDT) BLK NC2 YEL C2 VIO NO2 Basic rinciples of Design Reference ort Negative Rate Belleville Disc Spring Snap Aaction Electrical All Stainless Element Steel Construction Electrical Assembly Actuator ressure late Diaphragm ressure ort Glass to Metal Sealed Header Motion Transfer Arm O-Rings Neo-Dyn Industry Drive Valencia, CA tel: fax: AER0935_31 7/13 Specifications and dimensions subject to change.

60 Neo-Dyn Neo-Dyn Series 200 ressure Switch/Internal Versatile Nega-Rate Belleville disc spring pressure switch for use in hazardous areas. Series 200 (piston sensor) for hydraulic applications up to psig system pressure. Operating ressure Data Adjustable Range Adjustable Set oint Range Deadband (approximate) Number Increasing 20 to to to to Decreasing 14 to to to to 9000 Min Bar Bar All values given in psig. The deadband increases as the adjustable set point is increased. *Diminished safety factor equal to approximately 2:1. **Diminished safety factor equal to approximately 1.3:1. Standard Specifications Electrical Snap action electrical switch assemblies, art Numbers & (Form C) and & (Form CC), are listed by Underwriters Laboratories, Inc., FM Approvals, CSA International and NCC (INMETRO). See the miscellaneous option N for additional listings. Electrical Connection 1/2 NT male conduit connection with VC insulated 18 AWG, 18" long leads ressure Connection 1 1/4 NT Female Temperature Range* Ambient: - 40 F to +180 F (-40 C to +82 C) Media: - 40 F to +300 F (-40 C to +149 C) *Temperature limits change with O-Ring selection. See Electrical Assembly specification sheet for Temperature Class Ratings. Concealed wrench flat adjustment with range scale Shipping Weight Approximately 3 pounds Maximum Recommended System ressure * Ordering Sequence Select desired option for each category OTIONS 1 Aluminum port and piston, Teflon seal and Buna-N O-Ring 2 14 psig dec. to 220 psig inc. (1.0 bar dec. to 15.2 bar inc.) psig dec. to 1500 psig inc. (10.3 bar dec. to bar inc.) psig dec. to 3000 psig inc. (25.9 bar dec. to bar inc.) psig dec. to psig inc. (55.2 bar dec. to bar inc.) C 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; CC 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; 6 Includes an explosion proof, hermetically-sealed electrical assembly. EX d IIC. Division 1 and 2, Class I, Groups A, B, C, and D; Class II, Groups E, F, and G. NEMA 4X, 7, and 9; I66. Leads are factory sealed and ressure Switches are Dual Seal Certified. A Epoxy paint exterior extra protection for severe environments B Viton O-Ring C ER O-Ring D SIL approval and marking, per IEC61508 (includes FMEA report) E 7/16" - 20 SAE Female ort I 3/4 NT conduit box with terminal strip (Groups C & D only, not available with N option) M Gold electrical contacts for extremely low current applications (1 Amp at 125 VAC; 1 Amp Res, 0.5 Amp Ind. at 28 VDC) N ATEX and IECEx with CE Mark R 72" Electrical free leads W Stainless steel screws exterior Special (Consult representative or factory) Non-catalog adjustable range and/or set point, deadband and proof pressure Media temperature capability from -65 F to +400 F roof ressure ** Order Option D Ordering rocedure Example Explosion roof Hermetically Sealed (NEMA 4X, 7, 9 and 13) When factory presetting is desired, stipulate set point, increasing or decreasing Insert available option number or letter designation as required C 6_ Series

61 Field Adjustable 14 to psig Series 200 Envelope Dimensions Conduit Connection ¹ ₂ NT ressure ort ¹ ₄ NT Dia. Mtg. Holes (2 places) 3.50 FORM "C" (SDT) FORM "CC" (DDT) BLK NC2 YEL C2 VIO NO2 Basic rinciples of Design All Stainless Steel Construction Electrical Assembly Glass to Metal Sealed Header Snap Action Electrical Element Actuator Minimum Bearing oints Teflon and O-Ring Seal Motion Transfer Arm iston Negative Rate Belleville Disc Spring ressure ort Neo-Dyn Industry Drive Valencia, CA tel: fax: AER0935_44 7/13 Specifications and dimensions subject to change.

62 Neo-Dyn Neo-Dyn Series 1128 Flanged ressure Switch/Diaphragm Sensor Flanged pressure switch for installations that formerly required a chemical seal with fill fluids. Reliable Nega-Rate Belleville disc spring sensing mechanism. Redundant seals with venting between seals for alarm or indication. 316 stainless steel body and hermetically sealed, explosion-proof electrical assembly well suited for hazardous or corrosive atmospheres. Operating ressure Data Adjustable Range Number Adjustable Set oint Range Increasing 3 to to to to to 325 Standard Specifications Electrical Snap action electrical switch assemblies, art Numbers & (Form C) and & (Form CC), are listed by Underwriters Laboratories, Inc., FM Approvals, CSA International and NCC (INMETRO). See the miscellaneous option N for additional listings. Electrical Connection 1/2 NT male conduit connection with VC insulated 18 AWG, 18 long leads ressure Connection 1 inch, 1/16 raised face flange per ANSI B Class 150 (150#) Class 300 (300#) Note: Customer responsible for gasket selection and installation. (Refer to Installation and Operating Instructions supplied with switch) Temperature Range* Ambient: - 40 F to +180 F (-40 C to +82 C) Media: - 40 F to +250 F (-40 C to +121 C) *Limited by gasket material selected Internal, slotted adjustment with range scale Shipping Weight Approximately 4.5 pounds Decreasing 1.5 to to to to to 290 Deadband (approximate) Maximum Recommended System ressure* 150# Flange 300# Flange roof ressure 150# Flange 300# Flange Steel Stainless Steel Stainless All values given in psig. *System pressure ratings are based on flanges of the lowest strength steel and 316 stainless at 250 F. Consult ANSI B 16.5 for increased ratings at lower temperatures. Ordering Sequence Select desired option for each category OTIONS psig dec. to 30 psig inc. (0.1 bar dec. to 2.1 bar inc.) 4 15 psig dec. to 80 psig inc. (1.0 bar dec. to 5.5 bar inc.) 5 60 psig dec. to 180 psig inc. (4.1 bar dec. to 12.4 bar inc.) psig dec. to 240 psig inc. (7.9 bar dec. to 16.5 bar inc.) psig dec. to 325 psig inc. (13.1 bar dec. to 22.4 bar inc.) (300# Flange only) C 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; CC 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; 6 Includes an explosion proof, hermetically-sealed electrical assembly. EX d IIC. Division 1 and 2, Class I, Groups A, B, C, and D; Class II, Groups E, F, and G. NEMA 4X, 7, and 9; I66. Leads are factory sealed and ressure Switches are Dual Seal Certified. A Epoxy paint exterior extra protection for severe environments I 3/4 NT conduit box with terminal strip (Groups C & D only, not available with N option) M Gold electrical contacts for extremely low current applications N ATEX Approval R 72" Electrical free leads Flange Size/Material 1 150# Steel 2 300# Steel 3 150# Stainless Steel 4 300# Stainless Steel Diaphragm Stainless Steel 6 Tantalum 7 Hastelloy C 9 Inconel Internal O-Rings 2 Kalrez 3 Viton 5 ER 8 Buna-N Special (Consult representative or factory) Non-catalog adjustable range and/or set point and deadband Explosion roof Hermetically Sealed (NEMA 4X, 7, 9 and 13) Ordering rocedure When factory presetting is desired, stipulate set point, increasing or decreasing Insert available option number or letter designation as required Example 11282CC6_ 265 Series Flange Size/Material Diaphragm Internal O-Rings

63 Field Adjustable 1.5 to 325 psig Series 112 Envelope Dimensions with indicator l. 9 FORM "C" (SDT) FORM "CC" (DDT) BLK NC2 YEL C2 VIO NO2 Basic rinciples of Design Neo-Dyn Industry Drive Valencia, CA tel: fax: AER0935_14 6/12 Specifications and dimensions subject to change.

64 Neo-Dyn Neo-Dyn Series 1228 ressure Switch/Internal Compact, adjustable pressure switch for low to mid-range process applications. Efficient Nega-Rate Belleville disc spring for set point stability and vibration resistance. Wide selection of wetted materials, 316 stainless steel body and interior, plus hermetically sealed explosion-proof electrical make this switch ideal for chemical process applications. Operating ressure Data Adjustable Range Number All values given in psig. Standard Specifications Electrical Snap action electrical switch assemblies, art Numbers & (Form C) and & (Form CC), are listed by Underwriters Laboratories, Inc., FM Approvals, CSA International and NCC (INMETRO). See the miscellaneous option N for additional listings. Electrical Connection 1/2 NT male conduit connection with VC insulated 18 AWG, 18 long leads ressure Connection 1/2 NT Female Temperature Range* Ambient: - 40 F to +180 F (-40 C to +82 C) Media: - 40 F to +250 F (-40 C to +121 C) *Temperature limits change with O-Ring selection. See Electrical Assembly specification sheet for Temperature Class Ratings. Internal, slotted adjustment nut with range scale Shipping Weight Approximately 2 pounds Order Option D Adjustable Set oint Range Deadband Increasing 3 to to to to to to to to 2300 Decreasing 1 to to to to to to to to 2200 (approximate) * See T higher pressures Maximum Recommended System ressure * 4000* 4000* 4000* 4000* Ordering Sequence Select desired option for each category roof ressure * 6000* 6000* 6000* 6000* OTIONS 2 1 psig dec. to 30 psig inc. (0.1 bar dec. to 2.1 bar inc.) 4 15 psig dec. to 80 psig inc. (1.0 bar dec. to 5.5 bar inc.) 0 67 psig dec. to 130 psig inc. (4.6 bar dec. to 9.0 bar inc.) 5 30 psig dec. to 250 psig inc. (2.1 bar dec. to 17.2 bar inc.) psig dec. to 400 psig inc. (12.1 bar dec. to 27.6 bar inc.) psig dec. to 725 psig inc. (22.8 bar dec. to 50.0 bar inc.) psig dec. to 1500 psig inc. (42.7 bar dec. to bar inc.) psig dec. to 2300 psig inc. (96.5 bar dec. to bar inc.) C 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; CC 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; 6 Includes an explosion proof, hermetically-sealed electrical assembly. EX d IIC. Division 1 and 2, Class I, Groups A, B, C, and D; Class II, Groups E, F, and G. NEMA 4X, 7, and 9; I66. Leads are factory sealed and ressure Switches are Dual Seal Certified. D SIL approval and marking, per IEC61508 (includes FMEA report) I 3/4 NT conduit box with terminal strip (Groups C & D only, not available with N option) M Gold electrical contacts for extremely low current applications (1 Amp at 125 VAC; 1 Amp Res, 0.5 Amp Ind. at 28 VDC) N ATEX and IECEx with CE Mark R 72" Electrical free leads T 6300 psig system, 9450 psig proof, 410 stainless steel screws (Range 5, 6, 7, 8 & 9 only) ort Material Stainless Steel 8 Monel Stainless Steel welded diaphragm (add 40) 9 Monel welded Inconel 7 Hastelloy C welded Hastelloy diaphragm (add 70) diaphragm (add 90) Diaphragm 1 olyimide 7 Hastelloy C Stainless Steel 9 Inconel 6 Tantalum Internal O-Rings 0 Welded (ort Material 5, 7 & 9 only) 5 ER 2 Kalrez 8 Buna-N 3 Viton Special (Consult representative or factory) Non-catalog adjustable range and/or set point and deadband Explosion roof Hermetically Sealed (NEMA 4X, 7, 9 and 13) Ordering rocedure When factory presetting is desired, stipulate set point, increasing or decreasing Insert available option number or letter designation as required Example 12284C6_443 Series ort Material Diaphragm Internal O-Rings

65 Field Adjustable 1 to 2300 psig Series 1228 Envelope Dimensions 5.75 FORM "C" (SDT) F FORM "CC" (DDT) BLK NC2 YEL C2 VIO NO2 Basic rinciples of Design Neo-Dyn Industry Drive Valencia, CA tel: fax: AER0935_17 8/13 Specifications and dimensions subject to change.

66 Neo-Dyn Neo-Dyn Series 123 ressure Switch/Internal Compact, adjustable pressure switch for low to mid-range process applications. Efficient Nega-Rate Belleville disc spring for set point stability and vibration resistance. 316 stainless steel exterior and interior plus hermetically sealed, explosion-proof electrical for atmospheric protection. The flush mount (welded diaphragm) process connection makes this switch ideal for viscous process applications. Operating ressure Data Adjustable Range Number All values given in psig. Standard Specifications Electrical Snap action electrical switch assemblies, art Numbers & (Form C) and & (Form CC), are listed by Underwriters Laboratories, Inc., FM Approvals, CSA International and NCC (INMETRO). See the miscellaneous option N for additional listings. Electrical Connection 1/2 NT male conduit connection with VC insulated 18 AWG, 18 long leads ressure Connection 1 1/2 NT Male Temperature Range Ambient: - 40 F to +180 F (-40 C to +82 C) Media: - 40 F to +250 F (-40 C to +121 C) Internal, slotted adjustment nut with range scale Shipping Weight Approximately 2.5 pounds Adjustable Set oint Range Increasing 3 to to to to to to to 2300 Decreasing 1 to to to to to to to 2200 Deadband (approximate) Maximum Recommended System ressure Ordering Sequence Select desired option for each category OTIONS stainless steel port and diaphragm heliarc welded 2 1 psig dec. to 30 psig inc. (0.1 bar dec. to 2.1 bar inc.) 4 15 psig dec. to 80 psig inc. (1.0 bar dec. to 5.5 bar inc.) 5 30 psig dec. to 250 psig inc. (2.1 bar dec. to 17.2 bar inc.) psig dec. to 400 psig inc. (12.1 bar dec. to 27.6 bar inc.) psig dec. to 725 psig inc. (22.8 bar dec. to 50.0 bar inc.) psig dec. to 1500 psig inc. (42.7 bar dec. to bar inc.) psig dec. to 2300 psig inc. (96.5 bar dec. to bar inc.) C 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; CC 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; 6 Includes an explosion proof, hermetically-sealed electrical assembly. EX d IIC. Division 1 and 2, Class I, Groups A, B, C, and D; Class II, Groups E, F, and G. NEMA 4X, 7, and 9; I66. Leads are factory sealed and ressure Switches are Dual Seal Certified. A Epoxy paint exterior extra protection for severe environments I 3/4 NT conduit box with terminal strip (Groups C & D only, not available with N option) M Gold electrical contacts for extremely low current applications N ATEX and IECEx with CE Mark R 72" Electrical free leads Special (Consult representative or factory) Non-catalog adjustable range and/or set point, deadband and proof pressure roof ressure Ordering rocedure Example Explosion roof Hermetically Sealed (NEMA 4X, 7, 9 and 13) When factory presetting is desired, stipulate set point, increasing or decreasing Insert available option number or letter designation as required CC6_ Series (specify)

67 Field Adjustable 1 to 2300 psig Series 123 Envelope Dimensions 2.00 HEX 5.10 Welded Flush Mount Stainless Steel Sensing Diaphragm 1.05 Access Cover 1.50 Sq. ressure ort 1¹ ₂ NT Conduit Connection ¹ ₂ NT Free Leads, 18 AWG 18.0 Min. Length FORM "C" (SDT) FORM "CC" (DDT) BLK NC2 YEL C2 VIO NO2 Basic rinciples of Design Snap Action Electrical Element Actuator Minimum Bearing oints Glass To Metal Sealed Header ressure ort ressure late All Stainless Steel Construction Electrical Assembly Motion Transfer Arm Negative Rate Belleville Disc Spring Welded Diaphragm Neo-Dyn Industry Drive Valencia, CA tel: fax: AER0935_18 6/12 Specifications and dimensions subject to change.

68 Neo-Dyn Neo-Dyn Series 132 ressure Switch/Internal Compact adjustable pressure switch for low to mid-range process applications. Efficient Nega-Rate Belleville disc spring for set point stability and vibration resistance. Stainless steel wetted materials and hermetically sealed, explosion-proof electricals make this switch ideally suited for hazardous and corrosive media or environments. Operating ressure Data Adjustable Range Number All values given in psig. Standard Specifications Electrical Snap action electrical switch assemblies, art Numbers & (Form C) and & (Form CC), are listed by Underwriters Laboratories, Inc., FM Approvals, CSA International and NCC (INMETRO). See the miscellaneous option N for additional listings. Electrical Connection 1/2 NT male conduit connection with VC insulated 18 AWG, 18 long leads ressure Connection 1/4 NT Female Temperature Range* Ambient: - 40 F to +180 F (-40 C to +82 C) Media: - 40 F to +250 F (-40 C to +121 C) * Temperature limits change with O-Ring selection. See Electrical Assembly specification sheet for Temperature Class Ratings. Internal, slotted adjustment nut with range scale Shipping Weight Approximately 20 ounces Order Option D Adjustable Set oint Range Deadband Increasing 3 to to to to to to to to 2300 Decreasing 1 to to to to to to to to 2200 (approximate) * See T for higher pressures. Maximum Recommended System ressure * 4000* 4000* 4000* 4000* Ordering Sequence Select desired option for each category OTIONS stainless steel port and diaphragm, Buna-N O-Ring stainless steel port and diaphragm heliarc welded 8 1 psig dec. to 30 psig inc. (0.1 bar dec. to 2.1 bar inc.) 9 15 psig dec. to 80 psig inc. (1.0 bar dec. to 5.5 bar inc.) 0 67 psig dec. to 130 psig inc. (4.6 bar dec. to 9.0 bar inc.) 1 30 psig dec. to 250 psig inc. (2.1 bar dec. to 17.2 bar inc.) psig dec. to 400 psig inc. (12.1 bar dec. to 27.6 bar inc.) psig dec. to 725 psig inc. (22.8 bar dec. to 50.0 bar inc.) psig dec. to 1500 psig inc. (42.7 bar dec. to bar inc.) psig dec. to 2300 psig inc. (96.5 bar dec. to bar inc.) C 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; CC 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; roof ressure * 6000* 6000* 6000* 6000* 6 Includes an explosion proof, hermetically-sealed electrical assembly. EX d IIC. Division 1 and 2, Class I, Groups A, B, C, and D; Class II, Groups E, F, and G. NEMA 4X, 7, and 9; I66. Leads are factory sealed and ressure Switches are Dual Seal Certified.. A Epoxy paint exterior extra protection for severe environments B Viton O-Ring C ER O-Ring D SIL approval and marking, per IEC61508 (includes FMEA report) E 7/16" - 20 SAE Female ort G 1/2 NT Female ort H Stainless steel body I 3/4 NT conduit box with terminal strip (Groups C & D only, not available with N option) J Annealed stainless steel port screws for H 2 S environments Consult factory for reduced system and proof pressure ratings M Gold electrical contacts for extremely low current applications (1 Amp at 125 VAC; 1 Amp Res, 0.5 Amp Ind. at 28 VDC) N ATEX and IECEx with CE Mark O Cleaned for Oxygen Service R 72" Electrical free leads T 6300 psig system, 9450 psig proof, 410 stainless steel screws (Range 1 thru 7 only) Explosion roof Hermetically Sealed (NEMA 4X, 7, 9 and 13) Special (Consult representative or factory) Non-catalog adjustable range and/or set point, deadband and proof pressure Ordering rocedure Example When factory presetting is desired, stipulate set point, increasing or decreasing Insert available option number or letter designation as required CC6_ Series

69 Field Adjustable 1 to 2300 psig Series 132 Envelope Dimensions SQ 1.2 Cover Free Leads 18 AWG 18" Long ressure ort Z\v NT.209 Dia. Mtg. Holes (2 places) Conduit Connection Z\x NT FORM "C" (SDT) FORM "CC" (DDT) BLK NC2 YEL C2 VIO NO2 Basic rinciples of Design Glass to Metal Sealed Header Snap Action Electrical Element Actuator Minimum Bearing oints Diaphragm All Stainless Steel Construction Electrical Assembly Motion Transfer Arm Negative Rate Belleville Disc Spring O-Ring ressure ort Neo-Dyn Industry Drive Valencia, CA tel: fax: AER0935_25 8/13 Specifications and dimensions subject to change.

70 Neo-Dyn Neo-Dyn Series 232 ressure Switch/Internal Compact, adjustable pressure switch for high pressure hydraulic process applications. Efficient Nega-Rate Belleville disc spring for set point stability and vibration resistance. Stainless steel wetted materials and hermetically sealed, explosion-proof electricals make this switch ideally suited for hazardous and corrosive media or environments. Operating ressure Data Adjustable Range Number All values given in psig. Standard Specifications Electrical Snap action electrical switch assemblies, art Numbers & (Form C) and & (Form CC), are listed by Underwriters Laboratories, Inc., FM Approvals, CSA International and NCC (INMETRO). See the miscellaneous option N for additional listings. Electrical Connection 1/2 NT male conduit connection with VC insulated 18 AWG, 18" long leads ressure Connection 1/4 NT Female Temperature Range* Ambient: - 40 F to +180 F (-40 C to +82 C) Media: - 40 F to +250 F (-40 C to +121 C) * Temperature limits change with O-Ring selection. See Electrical Assembly specification sheet for Temperature Class Ratings Internal, slotted adjustment nut with range scale Shipping Weight Approximately 20 ounces Order Option D Adjustable Set oint Range Increasing 50 to to to to to to Decreasing 25 to to to to to to 9000 Deadband (approximate) Ordering Sequence Select desired option for each category OTIONS stainless steel port and piston, Buna-N O-Ring Maximum Recommended System ressure roof ressure psig dec. to 275 psig inc. (1.7 bar dec. to 19.0 bar inc.) 2 75 psig dec. to 1000 psig inc. (5.2 bar dec. to 69.0 bar inc.) psig dec. to 3100 psig inc. (48.3 bar dec. to bar inc.) psig dec. to 6000 psig inc. (158.6 bar dec. to bar inc.) psig dec. to 8500 psig inc. (337.9 bar dec. to bar inc.) psig dec. to psig inc. (413.7 bar dec. to bar inc.) C 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; CC 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; 6 Includes an explosion proof, hermetically-sealed electrical assembly. EX d IIC. Division 1 and 2, Class I, Groups A, B, C, and D; Class II, Groups E, F, and G. NEMA 4X, 7, and 9; I66. Leads are factory sealed and ressure Switches are Dual Seal Certified. A Epoxy paint exterior extra protection for severe environments B Viton O-Ring C ER O-Ring D SIL approval and marking, per IEC61508 (includes FMEA report) E 7/16" - 20 SAE Female ort G 1/2 NT Female ort H 316 stainless steel body I 3/4 NT conduit box with terminal strip (Groups C & D only, not available with N option) J Annealed stainless steel port screws for H 2 S environments Consult factory (Not available with range 4,5 & 6) M Gold electrical contacts for extremely low current applications (1 Amp at 125 VAC; 1 Amp Res, 0.5 Amp Ind. at 28 VDC) N ATEX and IECEx with CE Mark R 72" Electrical free leads Special (Consult representative or factory) Non-catalog adjustable range and/or set point, deadband and proof pressure Ordering rocedure Example Explosion roof Hermetically Sealed (NEMA 4X, 7, 9 and 13) When factory presetting is desired, stipulate set point, increasing or decreasing Insert available option number or letter designation as required CC6_ Series (specify)

71 Field Adjustable 25 to psig Series 232 Envelope Dimensions SQ 1.8 Cover Free Leads 18 AWG 18" Long ressure ort Z\v NT.209 Dia. Mtg. Holes (2 places) Conduit Connection Z\x NT FORM "C" (SDT) FORM "CC" (DDT) BLK NC2 YEL C2 VIO NO2 Basic rinciples of Design Glass to Metal Sealed Header Snap Action Electrical Element Actuator Minimum Bearing oints Teflon & O-Ring Seal All Stainless Steel Construction Electrical Assembly Motion Transfer Arm Negative Rate Belleville Disc Spring iston ressure ort Neo-Dyn Industry Drive Valencia, CA tel: fax: AER0935_51 7/13 Specifications and dimensions subject to change.

72 Neo-Dyn Neo-Dyn Series 130 ressure Switch/Tamper Resistant Compact, versatile pressure switch well suited for hazardous or corrosive atmospheres. For low to mid-range pressure applications. Features efficient Nega-Rate Belleville disc spring for superior set point stability and is field adjustable using 1/8" allen wrench through the port. Once adjustments are made and the switch is installed, it becomes tamper proof. Operating ressure Data Adjustable Range Number Adjustable Set oint Range Increasing 2 to to to to to to 170 Decreasing 1 to 11 7 to to to to to 155 Deadband (approximate) Maximum Recommended System ressure roof ressure All values given in psig. Standard Specifications Electrical Snap action electrical switch assemblies, art Numbers & (Form C) and & (Form CC), are listed by Underwriters Laboratories, Inc., FM Approvals, CSA International and NCC (INMETRO). See the miscellaneous option N for additional listings. Electrical Connection 1/2 NT male conduit connection with VC insulated 18 AWG, 18 long leads ressure Connection 1/4 NT Male Temperature Range* Ambient: - 40 F to +180 F (-40 C to +82 C) Media: - 40 F to +300 F (-40 C to +149 C) *Temperature limits change with O-Ring selection. See Electrical Assembly specification sheet for Temperature Class Ratings. 1/8" allen wrench through port Shipping Weight Approximately 16 ounces Ordering Sequence Select desired option for each category OTIONS 1 Aluminum port, Teflon coated polyimide diaphragm, Buna-N O-Ring stainless steel port, Teflon coated polyimide diaphragm, Buna-N O-Ring 1 1 psig dec. to 12 psig inc. (0.1 bar dec. to 0.8 bar inc.) 2 7 psig dec. to 30 psig inc. (0.5 bar dec. to 2.1 bar inc.) 3 25 psig dec. to 50 psig inc. (1.7 bar dec. to 3.4 bar inc.) 4 44 psig dec. to 70 psig inc. (3.0 bar dec. to 4.8 bar inc.) 5 60 psig dec. to 120 psig inc. (4.1 bar dec. to 8.3 bar inc.) psig dec. to 170 psig inc. (7.2 bar dec. to 11.7 bar inc.) C 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; CC 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; 6 Includes an explosion proof, hermetically-sealed electrical assembly. EX d IIC. Division 1 and 2, Class I, Groups A, B, C, and D; Class II, Groups E, F, and G. NEMA 4X, 7, and 9; I66. Leads are factory sealed and ressure Switches are Dual Seal Certified. A Epoxy paint exterior extra protection for severe environments B Viton O-Ring C ER O-Ring D SIL approval and marking, per IEC61508 (includes FMEA report) H 316 Stainless steel body I 3/4 NT conduit box with terminal strip (Groups C & D only, not available with N option) M Gold electrical contacts for extremely low current applications (1 Amp at 125 VAC; 1 Amp Res, 0.5 Amp Ind. at 28 VDC) N ATEX and IECEx with CE Mark R 72" Electrical free leads S Stainless steel diaphragm ( 4 only) Order Option D Ordering rocedure Example Explosion roof Hermetically Sealed (NEMA 4X, 7, 9 and 13) When factory presetting is desired, stipulate set point, increasing or decreasing Insert available option number or letter designation as required C 6_ Series

73 Field Adjustable 1 to 170 psig Series 130 Envelope Dimensions ¼ ½ FORM "C" (SDT) FORM "CC" (DDT) BLK NC2 YEL C2 VIO NO2 Basic rinciples of Design Neo-Dyn Industry Drive Valencia, CA tel: fax: AER0935_22 7/13 Specifications and dimensions subject to change.

74 Neo-Dyn Neo-Dyn Series 131 ressure Switch/Internal Compact, adjustable pressure switch for pneumatic and low impulse hydraulic process applications. Using our efficient Nega-Rate Belleville disc spring, we offer superior set point stability and vibration resistance. The 131 series pressure switch also has a selectable deadband feature which can be preset to fit most any application. Operating ressure Data Adjustable Range Adjustable Set oint Range Number Increasing Decreasing 2 * 1 to 24 3 * 17 to 42 4 * 1 to 50 5 * 45 to * 90 to * 140 to 200 All values given in psig unless otherwise noted. * Add selected deadband to decreasing pressure range. Standard Specifications Electrical Listings Snap action electrical switch assemblies, art Numbers & (Form C) and & (Form CC), are listed by Underwriters Laboratories, Inc., FM Approvals, CSA International and NCC (INMETRO). See the miscellaneous option N for additional listings. Electrical Connection 1/2 NT male conduit connection with VC insulated 18 AWG, 18 long leads ressure Connection 1/4 NT Female and 1/2 NT Male Temperature Range* Ambient: - 40 F to +180 F (-40 C to +82 C) Media: - 40 F to +300 F (-40 C to +149 C) * Temperature limits change with O-Ring selection. See Electrical Assembly specification sheet for Temperature Class Ratings. Internal, slotted adjustment wheel Shipping Weight Approximately 20 ounces Order Option D Selectable Deadband at a Specified Set oint 1 to to 5 7 to 11 7 to 11 9 to to 21 Default Deadband (approx.) Maximum Recommended System ressure Ordering Sequence Select desired option for each category OTIONS 1 Aluminum port, polyimide diaphragm, Buna-N O-Ring stainless steel port, polyimide diaphragm, Buna-N O-Ring 2 1 psig dec. to 25 psig inc. (.069 bar dec. to 1.72 bar inc.) 3 17 psig dec. to 46 psig inc. (1.17 bar dec. to 3.17 bar inc.) 4 1 psig dec. to 59 psig inc. (.069 bar dec. to 4.07 bar inc.) 5 45 psig dec. to 109 psig inc. (3.10 bar dec. to 7.51 bar inc.) 6 90 psig dec. to 163 psig inc. (6.21 bar dec. to 11.2 bar inc.) psig dec. to 216 psig inc. (9.65 bar dec. to 14.9 bar inc.) C 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; CC 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; roof ressure Includes an explosion proof, hermetically-sealed electrical assembly. EX d IIC. Division 1 and 2, Class I, Groups A, B, C, and D; Class II, Groups E, F, and G. NEMA 4X, 7, and 9; I66. Leads are factory sealed and ressure Switches are Dual Seal Certified. A Epoxy paint exterior extra protection for severe environments B Viton O-Ring C ER O-Ring D SIL approval and marking, per IEC61508 (includes FMEA report) E 7/16" - 20 SAE Female ort G 1/2 NT Female ort H 316 stainless steel body ( 4 only) I 3/4 NT conduit box with terminal strip (Groups C & D only, not available with N option) J Annealed stainless steel port screws for H 2 S environments Consult factory for reduced system and proof pressure ratings (Not available with Z option) M Gold electrical contacts for extremely low current applications (1 Amp at 125 VAC; 1 Amp Res, 0.5 Amp Ind. at 28 VDC) N ATEX and IECEx with CE Mark R 72" Electrical free leads S Stainless steel diaphragm V 1/4 NT male port Z Mounting bracket kit (Not available with J option) Special (Consult representative or factory) Non-catalog adjustable range and/or set point, deadband and proof pressure Explosion roof Hermetically Sealed (NEMA 4X, 7, 9 and 13) Ordering rocedure When factory presetting is desired, stipulate set point, increasing or decreasing Insert available option number or letter designation as required When a selectable DB is desired, stipulate DB within allowed range Example CC6 _ Series (specify)

75 Field Adjustable 1 to 216 psig Series 131 Envelope Dimensions 1.77* () 1.50 SQ Cover Mounting Brackets, Optional Free Leads 18 AWG 18" MIN 2.13 ressure ort ¹ ₂ NT Male ¹ ₄ NT Female 1.22 Conduit Connection ¹ ₂ NT *1.90 with Mounting Bracket FORM "C" (SDT) FORM "CC" (DDT) BLK NC2 YEL C2 VIO NO2 Basic rinciples of Design Negative Rate Belleville Disc Spring ressure ort Wheel Snap Action Electrical Element All Stainless Steel Construction Electrical Assembly Glass to Metal Sealed Header Neo-Dyn Industry Drive Valencia, CA tel: fax: AER0935_24 11/14 Specifications and dimensions subject to change.

76 Neo-Dyn Neo-Dyn Series 231 ressure Switch/Internal Compact, adjustable pressure switch for high pressure hydraulic process applications. Our combined piston sensor and efficient Nega-Rate Belleville disc spring offers superior set point stability and vibration resistance. Operating ressure Data Adjustable Range Adjustable Set oint Range Number Increasing * * * * * * Decreasing 250 to to to to to to 9000 All values given in psig unless otherwise noted. * Add selected deadband to decreasing pressure range. Standard Specifications Deadband (approximate) Maximum Recommended System ressure ,500 Ordering Sequence Select desired option for each category roof ressure ,000 Electrical Listings Snap action electrical switch assemblies, art Numbers & (Form C) and & (Form CC), are listed by Underwriters Laboratories, Inc., FM Approvals, CSA International and NCC (INMETRO). See the miscellaneous option N for additional listings. Electrical Connection 1/2 NT male conduit connection with VC insulated 18 AWG, 18" long leads ressure Connection 1/4 NT Female and 1/2 NT Male (N/A Range 8) Temperature Range* Ambient: -40 F to +180 F (-40 C to +82 C) Media: -40 F to +300 F (-40 C to +149 C) * Temperature limits change with O-Ring selection. See Electrical Assembly specification sheet for Temperature Class Ratings. Internal, slotted adjustment nut Shipping Weight Approximately 20 ounces Order Option D OTIONS 1 Aluminum port and piston, teflon seal, and Buna-N O-Ring (Not available for range 8) stainless steel port and piston, teflon seal, and Buna-N O-Ring psig dec. to 800 psig inc. (17.3 bar dec. to 55.1 bar inc.) psig dec. to 1190 psig inc. (41.4 bar dec. to 82.0 bar inc.) psig dec. to 3000 psig inc. (48.3 bar dec. to 207 bar inc.) psig dec. to 4850 psig inc. (165 bar dec. to 334 bar inc.) psig dec. to 7000 psig inc. (283 bar dec. to 483 bar inc.) psig dec. to 10,000 psig inc. (379 bar dec. to 689 bar inc.) C 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; CC 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; 6 Includes an explosion proof, hermetically-sealed electrical assembly. EX d IIC. Division 1 and 2, Class I, Groups A, B, C, and D; Class II, Groups E, F, and G. NEMA 4X, 7, and 9; I66. Leads are factory sealed and ressure Switches are Dual Seal Certified. A Epoxy paint exterior extra protection for severe environments B Viton O-Ring C ER O-Ring D SIL approval and marking, per IEC61508 (includes FMEA report) H 316 stainless steel body ( 4 only) I 3/4 NT Conduit box with terminal strip (Groups C & D only, not available with N option) J Annealed stainless steel port screws for H 2 S environments Consult factory for reduced system and proof pressure ratings M Gold electrical contacts for extremely low current applications N ATEX and IECEx with CE Mark R 72" Electrical free leads Z Mounting bracket kit Special (Consult representative or factory) Non-catalog adjustable range and/or set point, deadband and proof pressure Ordering rocedure Example Explosion roof Hermetically Sealed (NEMA 4X, 7, 9 and 13) When factory presetting is desired, stipulate set point, increasing or decreasing Insert available option number or letter designation as required CC6_ Series (specify)

77 Field Adjustable 250 to 7000 psig Series 231 Envelope Dimensions 1.77* () 1.50 SQ Cover Mounting Brackets, Optional Free Leads 18 AWG 18" MIN 2.13 ressure ort ¹ ₂ NT Male ¹ ₄ NT Female ** 1.22 Conduit Connection ¹ ₂ NT * 1.90 with Mounting Bracket ** No ¹ ₄ NT for Range 8 FORM "C" (SDT) FORM "CC" (DDT) BLK NC2 YEL C2 VIO NO2 Basic rinciples of Design Negative Rate Belleville Disc Spring ressure ort Wheel Snap Action Electrical Element All Stainless Steel Construction Electrical Assembly iston O-Ring Glass to Metal Sealed Header Neo-Dyn Industry Drive Valencia, CA tel: fax: AER0935_49 7/13 Specifications and dimensions subject to change.

78 Neo-Dyn Neo-Dyn Series 115/115 ressure Switch/Tamper roof Compact, versatile pressure switch with built to order set points. This easy to install switch features the efficient Nega-Rate Belleville disc spring for the set and forget application. Operating ressure Data Series All values given in psig. Standard Specifications Deadband (Differential) The deadband can be selected anywhere from 1.5 psig or 8% (whichever is greater) to 45% of the set point Electrical Snap action electrical switch assemblies, art Numbers & (Form C) and & (Form CC), are listed by Underwriters Laboratories, Inc., FM Approvals, CSA International and NCC (INMETRO). See the miscellaneous option N for additional listings. Electrical Connection 1/2 NT male conduit connection with VC insulated 18 AWG, 18 long leads ressure Connection 1/4 NT Male Temperature Range* Ambient:- 40 F to F (-40 C to +82 C) Media: -40 F to +300 F (-40 C to +149 C) *Temperature limits change with O-Ring selection. See Electrical Assembly specification sheet for Temperature Class Ratings. Shipping Weight Approximately 14 ounces Fixed Set oint Range Increasing Decreasing 2 to to to to 220 Ordering Sequence Select desired option for each category OTIONS Set oints 115 between 1.5 psig dec. and 70 psig inc. (.10 bar dec. to 4.8 bar inc.) 115 between 65 psig dec. and 250 psig inc. (4.5 bar dec. to 17 bar inc.) 1 Aluminum port, Teflon coated polyimide diaphragm and Buna-N O-Ring Stainless steel port, Teflon coated polyimide diaphragm and Buna-N O-Ring C 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; CC 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; 6 Includes an explosion proof, hermetically-sealed electrical assembly. EX d IIC. Division 1 and 2, Class I, Groups A, B, C, and D; Class II, Groups E, F, and G. NEMA 4X, 7, and 9; I66. Leads are factory sealed and ressure Switches are Dual Seal Certified. A Epoxy paint exterior extra protection for severe environments B Viton O-Ring refer to C ER O-Ring refer to D SIL approval and marking, per IEC61508 (includes FMEA report) H 316 stainless steel housing I 3/4 NT conduit box with terminal strip (Groups C & D only, not available with N option) M Gold electrical contacts for extremely low current applications (1 Amp at 125 VAC; 1 Amp Res, 0.5 Amp Ind. at 28 VDC) N ATEX and IECEx R 72" Electrical free leads S Stainless steel diaphragm (115, 4 only. Not available on 115) W Stainless steel screws (automatically furnished with Option A and Wetted Material 4) Special (Consult representative or factory) ressure port per AS4395E04 Electrical connection per MS SL-3 Maximum Recommended System ressure Up to 600 Up to 600 roof ressure Up to 1000 Up to 1000 Order Option D Explosion roof (NEMA 4X, 7, 9 and 13) Ordering rocedure Specify set point, increasing or decreasing Specify deadband if pertinent Specify system pressure Specify proof pressure Specify media Insert available option as required Example 115 1CC 6 _-_ Series Customer Identification Number (numerically assigned by factory)

79 Factory Set/Tamper roof 1.5 to 250 psig Series 115/115 Envelope Dimensions Free Leads 18 AWG 18" Long 1.92 Dia. ressure ort ¹ ₄ NT Conduit Connection ¹ ₂ NT.87 (typ.) 1.75 (typ.) FORM "C" (SDT) FORM "CC" (DDT) BLK NC2 YEL C2 VIO NO2 Basic rinciples of Design O-Ring Minimum Bearing oints Negative Rate Belleville Disc Spring Motion Transfer Arm All Stainless Steel Construction Electrical Assembly ressure ort Diaphragm ressure late Snap Action Electrical Element Glass to Metal Sealed Header Neo-Dyn Industry Drive Valencia, CA tel: fax: AER0935_15 7/13 Specifications and dimensions subject to change.

80 Neo-Dyn Neo-Dyn Series 125 ressure Switch/Tamper roof Designed for high pressure pneumatic or low impulse hydraulic applications requiring a narrow deadband and tamper-proof set point. Has diaphragm sensor with efficient Nega-Rate Belleville disc spring for excellent accuracy and repeatability. Operating ressure Data Series 125 All values given in psig. Standard Specifications Electrical Snap action electrical switch assemblies, art Numbers & (Form C) and & (Form CC), are listed by Underwriters Laboratories, Inc., FM Approvals, CSA International and NCC (INMETRO). See the miscellaneous option N for additional listings. Deadband (Differential) The deadband can be selected anywhere from 20 psig (1.38 bar) or 8% (whichever is greater) to 45% of the set point Electrical Connection 1/2 NT male conduit connection with VC insulated 18 AWG, 18 long leads ressure Connection 1/4 NT Female Temperature Range* Ambient: - 40 F to +180 F (-40 C to +82 C) Media: - 40 F to +300 F (-40 C to +149 C) *Temperature limits change with O-Ring selection. See Electrical Assembly specification sheet for Temperature Class Ratings. Shipping Weight Approximately 1 pound Increasing 40 to 3050 Fixed Set oint Range Decreasing 20 to 2800 Maximum Recommended System ressure Ordering Sequence Select desired option for each category OTIONS 125 between 20 psig dec. and 3050 psig inc. (1.4 bar dec. and 210 bar inc.) 1 Aluminum port, Teflon coated polyimide diaphragm and Buna-N O-Ring Stainless steel port, Teflon coated polyimide diaphragm and Buna-N O-Ring C 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; CC 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; 6 Includes an explosion proof, hermetically-sealed electrical assembly. EX d IIC. Division 1 and 2, Class I, Groups A, B, C, and D; Class II, Groups E, F, and G. NEMA 4X, 7, and 9; I66. Leads are factory sealed and ressure Switches are Dual Seal Certified. A Epoxy paint exterior extra protection for severe environments B Viton O-Ring C ER O-Ring D SIL approval and marking, per IEC61508 (includes FMEA report) I 3/4 NT conduit box with terminal strip (Groups C & D only, not available with N option) M Gold electrical contacts for extremely low current applications N ATEX and IECEx with CE Mark R 72" Electrical free leads W Stainless steel screws 5000 Special (Consult representative or factory) 7/16-20 SAE Female ort Electrical connection per MS SL-3 Non-catalog set point, deadband and/or proof pressure Media temperature capability from -65 F to +350 F roof ressure 7500 Order Option D Explosion roof Hermetically Sealed (NEMA 4X, 7, 9 and 13) Ordering rocedure Specify set point, increasing or decreasing Specify deadband if pertinent Specify media Insert available option number or letter designation as required Example 125 1CC 6 _-_ Series Customer Identification Number (numerically assigned by factory)

81 Factory Set/Tamper roof 20 to 3050 psig Series 125 Envelope Dimensions 1/4 1/2 FORM "C" (SDT) FORM "CC" (DDT) BLK NC2 YEL C2 VIO NO2 Basic rinciples of Design Neo-Dyn Industry Drive Valencia, CA tel: fax: AER0935_20 7/13 Specifications and dimensions subject to change.

82 Neo-Dyn Neo-Dyn Series 225 ressure Switch/Tamper roof A sealed piston sensor with a efficient Nega-Rate Belleville disc spring makes this switch well suited for high impulse hydraulic applications with tamper-proof set point. Operating ressure Data Series Fixed Set oint Range Increasing 45 to to to 7500 Decreasing 15 to to to 6750 All values given in psig. *Diminished safety factor equal to approximately 2:1 **Diminished safety factor equal to approximately 1.3:1 Deadband (minimums) 30 or 10% 160 or 10% 10% Maximum Recommended System ressure Hydraulic ,000* neumatic roof ressure Hydraulic ,000** neumatic Standard Specifications Deadband (Differential) The deadband can be selected anywhere from the minimum tabulated to a maximum of 45% of the set point Electrical Snap action electrical switch assemblies, art Numbers & (Form C) and & (Form CC), are listed by Underwriters Laboratories, Inc., FM Approvals, CSA International and NCC (INMETRO). See the miscellaneous option N for additional listings. Electrical Connection 1/2 NT male conduit connection with VC insulated 18 AWG, 18" long leads ressure Connection 1/4 NT Female Temperature Range* Ambient: - 40 F to +180 F (-40 C to +82 C) Media: - 40 F to +300 F (-40 C to +149 C) *Temperature limits change with O-Ring selection. See Electrical Assembly specification sheet for Temperature Class Ratings. Shipping Weight Approximately 1 pound Ordering Sequence Select desired option for each category OTIONS Set oints 225 between 15 psig dec. and 450 psig inc. (1.0 bar dec. and 31 bar inc.) 225 between 250 psig dec. and 3000 psig inc. (17 bar dec. and 207 bar inc.) 225 between 2701 psig dec. and 7500 psig inc. (186 bar dec. and 517 bar inc.) 1 Aluminum port and piston, Teflon seal and Buna-N O-Ring C 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; CC 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; 6 Includes an explosion proof, hermetically-sealed electrical assembly. EX d IIC. Division 1 and 2, Class I, Groups A, B, C, and D; Class II, Groups E, F, and G. NEMA 4X, 7, and 9; I66. Leads are factory sealed and ressure Switches are Dual Seal Certified. A Epoxy paint exterior extra protection for severe environments B Viton O-Ring C ER O-Ring D SIL approval and marking, per IEC61508 (includes FMEA report) I 3/4 NT Conduit box with terminal strip (Groups C & D only, not available with N option) M Gold electrical contacts for extremely low current applications N ATEX and IECEx with CE Mark R 72" Electrical free leads W Stainless steel screws Special (Consult representative or factory) ressure port per MS33649E4 Electrical connection per MS SL-3 Non-catalog set point, deadband and/or proof pressure Media temperature capability from -65 F to +350 F Stainless steel Aminco port with 9/16" - 18 UNF-3B THD Order Option D Explosion roof Hermetically Sealed (NEMA 4X, 7, 9 and 13) Ordering rocedure Specify set point, increasing or decreasing Specify deadband Specify media Insert available option number or letter designation as required Example 225 1CC 6 _-_ Series Customer Identification Number (numerically assigned by factory)

83 Field Adjustable 15 to 7500 psig Series 225 Envelope Dimensions FORM "C" (SDT) FORM "CC" (DDT) BLK NC2 YEL C2 VIO NO2 Basic rinciples of Design Neo-Dyn Industry Drive Valencia, CA tel: fax: AER0935_47 7/13 Specifications and dimensions subject to change.

84 GENERAL UROSE VACUUM SWITCHES NEMA 4, 4X & 13 déåéê~ä=mìêéçëé té~íüéê=mêççñ NQOm=pÉêáÉë Ultra Low Vacuum NUMm=pÉêáÉë High System ressure lbj péêáéë té~íüéê=mêççñ NUNm=pÉêáÉë Compact Vacuum Switch NUOm=pÉêáÉë Adjustable Thru ort Cap - Vacuum ^Çàìëí~ÄäÉ ^Çàìëí~ÄäÉ 9 10 HAZARDOUS AREA VACUUM SWITCHES NEMA 7 & 9 eéêãéíáå~ääó=pé~äéçlbñéäçëáçå=mêççñ= NQOm==pÉêáÉë Ultra Low Vacuum lbj péêáéë=eéêãéíáå~ääó=pé~äéçlbñéäçëáçå=mêççñ= NUNm=pÉêáÉë Compact Vacuum Switch NUOm=pÉêáÉë Adjustable Thru ort Cap - Vacuum ^Çàìëí~ÄäÉ c~åíçêó=péí 11 12

85 Neo-Dyn Neo-Dyn Series 1428 Ultra Low Vacuum/ressure Switch Ultra low pressure and vacuum to pressure crossover switch. Unique construction using efficient Nega-Rate Belleville disc spring for stable set points and high proof pressure. Wide range of wetted materials makes this series well suited for applications that formerly required the use of diaphragm seals. Operating ressure Data Adjustable Range Number Adjustable Set oint Range Increasing Deadband* (approximate) Maximum Recommended System ressure roof ressure 0 1" to 10" H 2 O.75" H 2 O 30" H 2 O Vacuum to 30" H 2 O ressure 30" H 2 O Vacuum to +5 psig 1 2" to 40" H 2 O 1" H 2 O 30" H 2 O Vacuum to +5 psig 30" H 2 O Vacuum to +15 psig 2 0" to 40" H 2 O Vacuum to 0" to 40" H 2 O ressure 1" H 2 O Full Vacuum to +15 psig Full Vacuum to 100 psig *Deadband 50% wider with "CC" (DDT) and "Z" (Double Break) s. Standard Specifications Electrical Snap action electrical switch recognized by Underwriters Laboratories, Inc. and CSA International Electrical Connection 1/2 NT female conduit connection with terminal block ressure Connection 1/2 NT Female Temperature Range* Ambient: - 40 F to +180 F (-40 C to +82 C) Media: - 50 F to +250 F (-46 C to +121 C) *Temperature limits change with O-Ring selection Concealed wrench flat adjustment with range scale Shipping Weight Approximately 3.5 pounds Order Option D Ordering Sequence Select desired option for each category OTIONS 0.25" H 2 O (.62 mbar) dec. to 10" (24.9 mbar) H 2 O inc. 1 1" H 2 O (2.49 mbar) dec. to 40" (99.6 mbar) H 2 O inc. 2 40" H 2 O (99.6 mbar) inc. vac. to 40" (99.6 mbar) H 2 O inc. pressure C 15 amp at 125 or 250 VAC; 1/8 hp at 125 VAC; 1/4 hp at 250 VAC;.5 amp resistive,.04 amp inductive at 125 VDC CC 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive 28 VDC; Z 15 amp at 125 or 250 VAC; 1/4 hp at 125 VAC; 1/2 hp at 250 VAC; 1 amp resistive,.5 amp inductive at 125 VDC 3 Meets or exceeds the requirements of NEMA Type 3 3R, 3S, 4, 4X and 13 A Epoxy paint exterior extra protection for severe environments D SIL approval and marking, per IEC61508 (includes FMEA report) L Neon light indicator 115 VAC M Gold electrical contacts for extremely low current applications X CE Mark ort Material Stainless Steel 7 Hastelloy C Diaphragm 1 olyimide Stainless Steel 6 Tantalum 7 Hastelloy C O-Rings 2 Kalrez 3 Viton 5 ER 8 Buna-N Special (Consult representative or factory) Non-catalog adjustable range and/or set point and deadband Operating temperature capabilities from -65 F to 400 F Weather roof (NEMA 4 and 13) Ordering rocedure When factory presetting is desired, stipulate set point, increasing or decreasing Insert available option number or letter designation as required Example CC3_ 463 Series ort Material Diaphragm O-Rings

86 Field Adjustable 40" H 2 O vac. to 40" H 2 O Series 142 Envelope Dimensions Dia Conduit Connection ¹ ₂ NT Dia. Mtg. Holes (2 places) Reference ort ¹ ₄ NT DO NOT LUG Random Radial Location ressure ort ¹ ₂ NT FORM "C" (SDT) FORM "CC" (DDT) FORM "Z" (DOUBLE BREAK) NC NC BLK SCREW BLK YEL VIO NC2 C2 NO2 NO SCREW NO VIO SCREW Basic rinciples of Design Reference ort Negative Rate Belleville Disc Spring Snap Action Electrical Element Actuator ressure late Diaphragm ressure ort Terminal Strip O-Rings Neo-Dyn Industry Drive Valencia, CA tel: fax: AER0935_30 7/13 Specifications and dimensions subject to change.

87 Neo-Dyn Neo-Dyn Series 180 Vacuum ressure Switch/Internal Adjustable vacuum switch with efficient Nega-Rate Belleville disc spring sensing mechanism. Weather proof enclosure and stable set points makes this switch ideal for a wide variety of applications. Operating ressure Data Adjustable Range Number 4 All values given in psig. Adjustable Set oint Range Increasing Vacuum 3" to 28" Hg Decreasing Vacuum 1" to 26" Hg Deadband (approximate) 2" Hg Maximum Recommended System ressure 225 roof ressure 350 Standard Specifications Electrical Snap action electrical switch recognized by Underwriters Laboratories, Inc. and CSA International Electrical Connection 1/2 NT female conduit connection with terminal block ressure Connection 1/4 NT Female Temperature Range* Ambient: - 40 F to +180 F (-40 C to +82 C) Media: - 40 F to +250 F (-40 C to +121 C) *Temperature limits change with O-Ring selection Concealed wrench flat adjustment with range scale Shipping Weight Approximately 3.5 pounds Order Option D Ordering Sequence Select desired option for each category OTIONS 1 Aluminum port and body, Teflon coated polyimide diaphragm, Buna-N O-Rings and stainless steel 4 Stainless steel, Teflon coated polyimide diaphragm and Buna-N O-Rings Adjustable Vacuum Range 4 1" Hg dec. to 28" Hg inc. (0.0 bar dec. to 0.9 bar inc.) C 15 amp at 125 or 250 VAC; 1/8 hp at 125 VAC; 1/4 hp at 250 VAC;.5 amp resistive,.04 amp inductive at 125 VDC CC 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; 3 Meets or exceeds the requirements of NEMA Type 3, 3R, 3S, 4, 4X and 13 A Epoxy paint exterior extra protection for severe environments B Viton O-Ring C ER O-Ring D SIL approval and marking, per IEC61508 (includes FMEA report) L Neon indicator light 115 VAC M Gold electrical contacts for extremely low current applications X CE Mark Special (Consult representative or factory) Non-catalog adjustable range and/or set point, deadband and proof pressure Media temperature capability from -65 F to +350 F 10 amps 125 VDC electrical rating Chemical seals installed Optional orientation of Low ressure ort Ordering rocedure Example Weather roof (NEMA 4 and 13) When factory presetting is desired, stipulate set point, increasing or decreasing Insert available option number or letter designation as required C 3_ Series

88 Field Adjustable 1" to 28" Hg vac. Series 180 Envelope Dimensions ¹ ₄ NT Female Vacuum ort Dia. Mtg. Holes (2 places) 1.9 ¹ ₄ NT Reference ort Conduit Connection ¹ ₂ NT FORM "C" (SDT) V FORM "CC" (DDT) V SCREW BLK YEL NC2 C2 VIO NO 2 SCREW Basic rinciples of Design Snap Action Electrical Element Actuator Negative Rate Belleville Disc Spring Vacuum ort ressure late Reference ort Terminal Strip O-Rings Diaphragm Neo-Dyn Industry Drive Valencia, CA tel: fax: AER0935_38 7/13 Specifications and dimensions subject to change.

89 Neo-Dyn Neo-Dyn Series 181 Vacuum Switch/Internal Compact, adjustable vacuum switch well suited to numerous applications. Our efficient Nega-Rate Belleville disc spring offers superior set point stability and vibration resistance. The 181 series vacuum switch also has a selectable deadband feature which can be preset at the factory. Operating ressure Data Adjustable Range Number Adjustable Set oint Range Increasing Vacuum Decreasing Vacuum 2 4 to 28" Hg 2 to 26" Hg All values given in psig unless otherwise noted. Selectable Deadband 1.5 to 2.5" Hg Default Deadband (approx.) 2" Hg Maximum Recommended System ressure 150 roof ressure 250 Standard Specifications Electrical Listings Switch listed by Underwriters Laboratories, Inc., CSA International and Factory Mutual Electrical Connection 1/2 NT male conduit connection, 18" free leads ressure Connection 1/4 NT Female and 1/2 NT Male Temperature Range* Ambient: - 40 F to +176 F (-40 C to +80 C) Media: - 40 F to +300 F (-40 C to +149 C) * Temperature limits change with O-Ring selection Internal, slotted adjustment wheel Shipping Weight Approximately 13 ounces Order Option D Ordering Sequence Select desired option for each category OTIONS 1 Aluminum port, polyimide diaphragm, Buna-N O-Ring stainless steel port, polyimide diaphragm, Buna-N O-Ring Adjustable Vacuum Range 2 2" dec. to 28" Hg inc. C 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; CC 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; 3 Meets or exceeds the requirements of NEMA Type 3, 3R, 3S, 4, 4X and 13 A Epoxy paint exterior for extra protection for severe environments B Viton O-Ring C ER O-Ring D SIL approval and marking, per IEC61508 (includes FMEA report) I 3/4 NT Conduit box with terminal block M Gold electrical contacts for extremely low current applications R 72" Electrical free leads X CE Mark Z Mounting bracket kit Special (Consult representative or factory) Non-catalog adjustable range and/or set point, deadband and proof pressure Ordering rocedure Example Weather roof (NEMA 4X and 13) When factory presetting is desired, stipulate set point, increasing or decreasing Insert available option number or letter designation as required When a selectable deadband is desired, stipulate deadband within allowed range CC 3 _ Series (specify)

90 Field Adjustable 2 to 28 inches of mercury Series 181 Envelope Dimensions (Typ.) 5.10 Ø.222 Mounting Brackets, Optional ressure ½ NT Male ¼ NT FORM "C" (SDT) V FORM "CC" (DDT) V BLK NC2 (X OTION) YEL VIO C2 NO2 (X OTION) Basic rinciples of Design Negative Rate Belleville Disc S pring ressure ort Actuator Snap Action Electrical Element Diaphragm O-Ring Minimum Bearing oints Neo-Dyn Industry Drive Valencia, CA tel: fax: AER0935_39 7/13 Specifications and dimensions subject to change.

91 Neo-Dyn Neo-Dyn Series 182 Vacuum Switch / Tamper Resistant Compact, versatile vacuum switch suited to numerous applications. Features efficient Nega-Rate Belleville disc spring for stable set points and is field adjustable through the pressure port. Once adjustments are made and switch is installed, it becomes tamper proof. Operating ressure Data Adjustable Range Number 2 All values given in psig. Standard Specifications Adjustable Set oint Range Increasing Vacuum 4" to 28 Hg Decreasing Vacuum 2" to 26 Hg Deadband (approximate) 2 Hg Maximum Recommended System ressure Ordering Sequence Select desired option for each category 150 roof ressure 250 Electrical Snap action electrical switch recognized by Underwriters Laboratories, Inc. and CSA International Electrical Connection 1/2 NT male conduit connection with VC insulated 18 AWG, 18" long leads ressure Connection 1/4 NT Male Temperature Range* Ambient: - 40 F to +180 F (-40 C to +82 C) Media: - 40 F to +300 F (-40 C to +149 C) *Temperature limits change with O-Ring selection 1/8" allen wrench through port Shipping Weight Approximately 8 ounces OTIONS 1 Aluminum port, Teflon coated polyimide diaphragm, Buna-N O-Rings, stainless and cadmium plated steel 4 Stainless steel port, Teflon coated polyimide diaphragm and Buna-N O-Rings Adjustable Vacuum Range 2 2" Hg dec. to 28" Hg inc. vacuum (.07 bar dec. to.95 bar inc.) C 11 amp, 1/4 at 125 or 250 VAC; 5 amp resistive, 3 amp inductive 28 at VDC; CC 11 amp, 1/4 at 125 or 250 VAC; 5 amp resistive, 3 amp inductive 28 at VDC; 3 Meets or exceeds the requirements of NEMA Type 3, 3R, 3S, 4, 4X and 13 A Epoxy paint exterior extra protection for severe environments B Viton O-Ring C ER O-Ring D SIL approval and marking, per IEC61508 (includes FMEA report) I 1/2 NT Conduit box with terminal strip M Gold electrical contacts for extremely low current applications R 72" Electrical free leads X CE Mark Special (Consult representative or factory) Non-catalog adjustable range and/or set point, deadband and proof pressure Order Option D Ordering rocedure Example Weather roof (NEMA 4 and 13) When factory presetting is desired, stipulate set point, increasing or decreasing Insert available option number or letter designation as required CC3_ Series

92 Field Adjustable 2" to 28" Hg Series 182 Envelope Dimensions 4.15 Free Leads 18" Min. Length 18 AWG 1.50 SQ.65 Vacuum ort ¹ v ¼ NT Conduit Connection ¹ x ½ NT FORM "C" (SDT) V FORM "CC" (DDT) V (X-Option) BLK YEL NC2 C2 VIO NO 2 (X Option Only) Basic rinciples of Design Minimum Bearing oints O-Ring Actuator Vacuum ort Snap Action Electrical Element Diaphragm Negative Rate Belleville Spring Neo-Dyn Industry Drive Valencia, CA tel: fax: AER0935_40 7/13 Specifications and dimensions subject to change.

93 Neo-Dyn Neo-Dyn Series 1428 Ultra Low Vacuum/ressure Switch Ultra low pressure and vacuum to pressure crossover switch. Unique construction using efficient Nega-Rate Belleville disc spring for stable set points and high proof pressure. Explosion proof enclosure and wide range of wetted materials makes this switch especially well suited for hazardous or corrosive atmospheres. Operating ressure Data Adjustable Range Number Adjustable Set oint Range Increasing Deadband* (approximate) Maximum Recommended System ressure roof ressure 0 1" to 10" H 2 O.75" H 2 O 30" H 2 O Vacuum to 30" H 2 O ressure 30" H 2 O Vacuum to +5 psig 1 2 Standard Specifications Electrical Snap action electrical switch listed by Underwriters Laboratories, Inc., Factory Mutual and CSA International Electrical Connection 1/2 NT male conduit connection with VC insulated 18 AWG, 18 long leads ressure Connection 1/2 NT Female Temperature Range* Ambient: - 40 F to +180 F (-40 C to +82 C) Media: - 50 F to +250 F (-46 C to +121 C) *Temperature limits change with O-Ring selection. See Electrical Assembly specification sheet for Temperature Class Ratings. Concealed wrench flat adjustment with range scale Shipping Weight Approximately 3.5 pounds 2" to 40" H 2 O 0" to 40" H 2 O Vacuum to 0" to 40" H 2 O ressure *Deadband 50% wider with "CC" (DDT) s. Order Option D Explosion roof Hermetically Sealed (NEMA 4X, 7, 9 and 13) 1" H 2 O 1" H 2 O Ordering Sequence Select desired option for each category OTIONS 0.25" H2O (.62 mbar) dec. to 10" (24.9 mbar) H2O inc. 1 1" H2O (2.49 mbar) dec. to 40" (99.6 mbar) H2O inc. 2 40" H2O (99.6 mbar) inc. vac. to 40" (99.6 mbar) H2O inc. pressure C 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; CC 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; 6 Explosion proof, hermetically-sealed electrical assembly, EX d IIC. art Numbers & (Form C) and & (Form CC). Agency listings include Underwriters Laboratories, Inc., CSA International, Factory Mutual, and Inmetro. Division 1 and 2, Class I, Groups A, B, C, and D; Class II, Groups E, F, and G. NEMA 4X, 7, and 9; I66. Leads are factory sealed and ressure Switches are Dual Seal Certified. A Epoxy paint exterior extra protection for severe environments D SIL approval and marking, per IEC61508 (includes FMEA report) I 3/4 NT conduit box with terminal strip (Groups C & D only, not available with N option) M Gold electrical contacts for extremely low current applications N ATEX and IECEx with CE Mark R 72" Electrical free leads ort Material Stainless Steel 7 Hastelloy C Diaphragm 1 olyimide Stainless Steel 6 Tantalum 7 Hastelloy C O-Rings 2 Kalrez 3 Viton 5 ER 8 Buna-N Special (Consult representative or factory) Non-catalog adjustable range and/or set point, deadband and proof pressure Media temperature capabilities from -65 F to +400 F Ordering rocedure When factory presetting is desired, stipulate set point, increasing or decreasing Insert available option number or letter designation as required 30" H 2 O Vacuum to +5 psig Full Vacuum to +15 psig Example CC6_ " H 2 O Vacuum to +15 psig Full Vacuum to 100 psig Series ort Material Diaphragm O-Rings

94 Field Adjustable 40" H 2 O vac. to 40" H 2 O Series 142 Envelope Dimensions Free Leads 18 AWG 18" Long Dia Conduit Connection ¹ ₂ NT.265 Dia. Mtg. Holes (2 places) 3.50 Reference ort ¹ ₄ NT DO NOT LUG Random Radial Location ressure ort ¹ ₂ NT FORM "C" (SDT) FORM "CC" (DDT) BLK NC2 YEL C2 VIO NO2 Basic rinciples of Design Reference ort Negative Rate Belleville Disc Spring Snap Aaction Electrical All Stainless Element Steel Construction Electrical Assembly Actuator ressure late Diaphragm ressure ort Glass to Metal Sealed Header Motion Transfer Arm O-Rings Neo-Dyn Industry Drive Valencia, CA tel: fax: AER0935_31 7/13 Specifications and dimensions subject to change.

95 Neo-Dyn Neo-Dyn Series 181 Vacuum Switch/Internal Compact, adjustable vacuum switch well suited to numerous applications. Our efficient Nega-Rate Belleville disc spring offers superior set point stability and vibration resistance. The 181 series vacuum switch also has a selectable deadband feature which can be preset. Operating ressure Data Adjustable Range Number Adjustable Set oint Range Increasing Vacuum Decreasing Vacuum 2 4 to 28" Hg 2 to 26" Hg All values given in psig unless otherwise noted. Selectable Deadband 1.5 to 2.5" Hg Default Deadband (approx.) 2" Hg Maximum Recommended System ressure 150 roof ressure 250 Standard Specifications Electrical Listings Snap action electrical switch assemblies, art Numbers & (Form C) and & (Form CC), are listed by Underwriters Laboratories, Inc., FM Approvals, CSA International and NCC (INMETRO). See the miscellaneous option N for additional listings. Electrical Connection 1/2 NT male conduit connection with VS insulated 18 AWG, 18" long leads ressure Connection 1/4 NT Female and 1/2 NT Male Temperature Range* Ambient: - 40 F to +176 F (-40 C to +80 C) Media: - 40 F to +300 F (-40 C to +149 C) * Temperature limits change with O-Ring selection. See Electrical Assembly specification sheet for Temperature Class Ratings. Internal, slotted adjustment wheel Shipping Weight Approximately 20 ounces Ordering Sequence Select desired option for each category OTIONS 1 Aluminum port, polyimide diaphragm, Buna-N O-Ring stainless steel port, polyimide diaphragm, Buna-N O-Ring Adjustable Vacuum Range 2 2" Hg dec. to 28" Hg inc. C 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; CC 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; 6 Includes an explosion proof, hermetically-sealed electrical assembly. EX d IIC. Division 1 and 2, Class I, Groups A, B, C, and D; Class II, Groups E, F, and G. NEMA 4X, 7, and 9; I66. Leads are factory sealed and ressure Switches are Dual Seal Certified. A Epoxy paint exterior for extra protection for severe environments B Viton O-Ring C ER O-Ring D SIL approval and marking, per IEC61508 (includes FMEA report) D SAA Approval (current and temperature ratings vary) H 316 stainless Steel Body I 3/4 NT Conduit box with terminal strip (Groups C & D only, not available with N option) M Gold electrical contacts for extremely low current applications N ATEX and IECEx with CE Mark R 72" Electrical free leads Z Mounting bracket kit Special (Consult representative or factory) Non-catalog adjustable range and/or set point, deadband and proof pressure Order Option D Ordering rocedure Example Explosion roof Hermetically Sealed (NEMA 4X, 7, 9 and 13) When factory presetting is desired, stipulate set point, increasing or decreasing Insert available option number or letter designation as required When a selectable deadband is desired, stipulate deadband within allowed range CC 6 _ Series (specify)

96 Field Adjustable 2 to 28 inches of mercury Series 181 Envelope Dimensions SQ Cover lkooo Mounting Brackets, Optional Free Leads 18 AWG 18" MIN Conduit Connection ¹ ₂ NT ressure ort ¹ ₂ NT Male ¹ ₄ NT Female FORM "C" (SDT) V FORM "CC" (DDT) V BLK NC2 YEL C2 VIO NO2 Basic rinciples of Design Negative Rate Belleville Disc Spring ressure ort Wheel Snap Action Electrical Element All Stainless Steel Construction Electrical Assembly aá~éüê~öã Actuator Glass to Metal Sealed Header Neo-Dyn Industry Drive Valencia, CA tel: fax: AER0935_41 7/13 Specifications and dimensions subject to change.

97 Neo-Dyn Neo-Dyn Series 182 Vacuum Switch/Tamper Resistant Compact, versatile vacuum switch well suited for hazardous or corrosive atmospheres. For vacuum applications. Features efficient Nega-Rate Belleville disc spring for stable set points and is field adjustable using 1/8" allen wrench. Once adjustments are made and switch is installed, it becomes tamper proof. Operating ressure Data Adjustable Range Number 2 All values given in psig. Standard Specifications Electrical Snap action electrical switch assemblies, art Numbers & (Form C) and & (Form CC), are listed by Underwriters Laboratories, Inc., FM Approvals, CSA International and NCC (INMETRO). See the miscellaneous option N for additional listings. Electrical Connection 1/2 NT male conduit connection with VC insulated 18 AWG, 18" long leads ressure Connection 1/4 NT Male Temperature Range* Ambient: - 40 F to +180 F (-40 C to +82 C) Media: - 40 F to +300 F (-40 C to +149 C) *Temperature limits change with O-Ring selection. See Electrical Assembly specification sheet for Temperature Class Ratings. 1/8" allen wrench through port Shipping Weight Approximately 16 ounces Adjustable Set-oint Range Increasing Vacuum 4 to 28 Hg Decreasing Vacuum 2 to 26 Hg Deadband (approximate) 2 Hg Maximum Recommended System ressure Ordering Sequence Select desired option for each category OTIONS 1 Aluminum port, Teflon coated polyimide diaphragm, Buna-N O-Ring, stainless and cadmium plated steel 4 Stainless steel, Teflon coated polyimide diaphragm and Buna-N O-Ring Adjustable Vacuum Range 2 2" Hg dec. to 28" Hg inc. vacuum (.07 bar dec. to.95 bar inc.) C 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; CC 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; 6 Includes an explosion proof, hermetically-sealed electrical assembly. EX d IIC. Division 1 and 2, Class I, Groups A, B, C, and D; Class II, Groups E, F, and G. NEMA 4X, 7, and 9; I66. Leads are factory sealed and ressure Switches are Dual Seal Certified. A Epoxy paint exterior extra protection for severe environments B Viton O-Ring C ER O-Ring H Stainless steel body I 3/4 NT conduit box with terminal strip (Groups C & D only, not available with N option) M Gold electrical contacts for extremely low current applications N ATEX and IECEx with CE Mark R 72" Electrical free leads 150 roof ressure 250 Ordering rocedure Example Explosion roof Hermetically Sealed (NEMA 4X, 7, 9 and 13) When factory presetting is desired, stipulate set point, increasing or decreasing Insert available option number or letter designation as required CC6_ Series

98 Field Adjustable 2 to 28" Hg Series 182 Envelope Dimensions ¼ ½ FORM "C" (SDT) V FORM "CC" (DDT) V BLK NC2 YEL C2 VIO NO 2 Basic rinciples of Design Neo-Dyn Industry Drive Valencia, CA tel: fax: AER0935_42 7/13 Specifications and dimensions subject to change.

99 GENERAL UROSE DIFFERENTIAL SWITCHES NEMA 4, 4X & 13 déåéê~ä=mìêéçëé té~íüéê=mêççñ NROm=pÉêáÉë Ultra Low System ressure NSMm=pÉêáÉë Mid Range System ressure `çãé~åí té~íüéê=mêççñ NRNm=pÉêáÉë Low Differential Set oints w/mid Range System ressure ^Çàìëí~ÄäÉ ^Çàìëí~ÄäÉ HAZARDOUS AREA DIFFERENTIAL SWITCHES NEMA 7 & 9 eéêãéíáå~ääó=pé~äéçlbñéäçëáçå=mêççñ= NROm=pÉêáÉë Ultra Low System ressure NSMm=pÉêáÉë Mid Range System ressure `çãé~åí=eéêãéíáå~ääó=pé~äéçlbñéäçëáçå=mêççñ= NRNm=pÉêáÉë Low Differential Set oints w/mid Range System ressure NSOm=pÉêáÉë High System ressure ^Çàìëí~ÄäÉ ^Çàìëí~ÄäÉ 15 16

100 Neo-Dyn Neo-Dyn Series 1528 Ultra Low Differential/ressure Switch Ultra low adjustable pressure switch. Unique construction using efficient Nega-Rate Belleville disc spring for stable set points and high proof pressure. Wide range of wetted materials makes this series well suited for applications that formerly required the use of diaphragm seals. Operating ressure Data Adjustable Range Number 2 Standard Specifications Electrical Snap action electrical switch recognized by Underwriters Laboratories, Inc. and CSA International Electrical Connection 1/2 NT female conduit connection with terminal block ressure Connection High 1/2 NT Female Low 1/4 NT Female Temperature Range* Ambient: - 40 F to +180 F (-40 C to +82 C) Media: - 50 F to +250 F (-46 C to +121 C) *Temperature limits change with O-Ring selection Concealed wrench flat adjustment with range scale Shipping Weight Approximately 4 pounds Adjustable Set oint Range Increasing 2" to 100" H 2 O Differential Ordering Sequence Select desired option for each category OTIONS 2.5" H2O dec. (1.2 mbar) to 100" H2O inc. (249 mbar) C 15 amp at 125 or 250 VAC; 1/8 hp at 125 VAC; 1/4 hp at 250 VAC;.5 amp resistive,.04 amp inductive at 125 VDC CC 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; Z 15 amp at 125 or 250 VAC; 1/4 hp at 125 VAC; 1/2 hp at 250 VAC; 1 amp resistive,.5 amp inductive at 125 VDC 3 Meets or exceeds the requirements of NEMA Type 3 3R, 3S, 4, 4X and 13 A Epoxy paint exterior extra protection for severe environments D SIL approval and marking, per IEC61508 (includes FMEA report) L Neon light indicator 115 VAC M Gold electrical contacts for extremely low current applications ort Material Stainless Steel High/Aluminum Low Stainless Steel High/Low Diaphragm 1 olyimide Stainless Steel 6 Tantalum 7 Hastelloy C O-Rings 2 Kalrez 3 Viton 5 ER 8 Buna-N Deadband* (approximate) 1.5" H 2 O *Deadband 50% wider with "CC" (DDT) and "Z" (Double Break) s. Order Option D Maximum Recommended System ressure 15 psig Simul. or Hi over Low 100" H 2 O Low over Hi Special (Consult representative or factory) Non-catalog adjustable range and/or set point and deadband Media temperature capabilities from -65 F to 400 F roof ressure 100 SI Simul. or Hi over Low 15 SI Low over Hi Weather roof (NEMA 4 and 13) Ordering rocedure When factory presetting is desired, stipulate set point, increasing or decreasing and system pressure Insert available option number or letter designation as required Example CC3_ 463 Series ort Material Diaphragm O-Rings

101 Field Adjustable.5" H 2 0 to 100" H 2 0 Series 152 Envelope Dimensions N `çåçìáí SCREW FORM "C" (SDT) HIGH LOW BLK NC2 YEL C2 VIO NO2 SCREW FORM "CC" (DDT) HIGH LOW FORM "Z" (DOUBLE BREAK) NC NC NO SCREW HIGH LOW NO BLK VIO Basic rinciples of Design Neo-Dyn Industry Drive Valencia, CA tel: fax: AER0935_33 7/13 Specifications and dimensions subject to change.

102 Neo-Dyn Neo-Dyn Series 160 Differential ressure Switch Mid-range, adjustable differential pressure switch. Efficient Nega-Rate Belleville disc spring sensing mechanism. Weather proof enclosure and stable set points during system pressure changes makes this switch ideal for a wide variety of applications. Operating ressure Data Adjustable Range Number All values given in psid. Standard Specifications Electrical Snap action electrical switch recognized by Underwriters Laboratories, Inc. and CSA International Electrical Connection 1/2 NT female conduit connection with terminal block ressure Connections 1/4 NT Female Temperature Range* Ambient: - 40 F to +180 F (-40 C to +82 C) Media: - 40 F to +250 F (-40 C to +121 C) *Temperature limits change with O-Ring selection Concealed wrench flat adjustment with range scale Shipping Weight Approximately 3.5 pounds Order Option D Adjustable Set oint Range Increasing Decreasing 1.1 to to 18 5 to to to to to to 104 Deadband (approximate) Maximum Recommended System ressure Ordering Sequence Select desired option for each category OTIONS 1 Aluminum port and body, Teflon coated polyimide diaphragm, Buna-N O-Rings and stainless steel 4 Stainless steel, Teflon coated polyimide diaphragm and Buna-N O-Rings 2.75 psid dec. to 15 psid inc. (0.1 bar dec. to 1.0 bar inc.) 4.3 psid dec. to 18 psid inc. (0.0 bar dec. to 1.2 bar inc.) 6 2 psid dec. to 60 psid inc. (0.1 bar dec. to 4.1 bar inc.) 7 49 psid dec. to 110 psid inc. (3.4 bar dec. to 7.6 bar inc.) C 15 amp at 125 or 250 VAC; 1/8 hp at 125 VAC; 1/4 hp at 250 VAC;.5 amp resistive,.04 amp inductive at 125 VDC CC 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive 28 at VDC; 3 Meets or exceeds the requirements of NEMA Type 3, 3R, 3S, 4, 4X and 13 A Epoxy paint exterior extra protection for severe environments B Viton O-Ring C ER O-Ring D SIL approval and marking, per IEC61508 (includes FMEA report) L Neon indicator light 115 VAC M Gold electrical contacts for extremely low current applications (1 Amp at 125 VAC; 1 Amp Res, 0.5 Amp Ind. at 28 VDC) S Stainless steel diaphragm No low over high capability (Ranges 2 & 4 and 4 only) X CE Mark Special (Consult representative or factory) Non-catalog adjustable range and/or set point, deadband and proof pressure Media temperature capability from -65 F to +350 F 10 amps 125 VDC electrical rating Chemical seals installed Optional orientation of Low ressure ort roof ressure 500 Hi/Low 200 Low/Hi 1000 Hi/Low 400 Low/Hi 1000 Hi/Low 400 Low/Hi 1000 Hi/Low 400 Low/Hi Ordering rocedure Example Weather roof (NEMA 4 and 13) When factory presetting is desired, stipulate set point, increasing or decreasing and system pressure Insert available option number or letter designation as required C 3_ Series

103 Field Adjustable.3 to 110 psid Series 160 Envelope Dimensions Basic rinciples of Design Neo-Dyn Industry Drive Valencia, CA tel: fax: AER0935_35 7/13 Specifications and dimensions subject to change.

104 Neo-Dyn Neo-Dyn Series 151 Differential ressure Switch Low range adjustable differential pressure switch compact design features efficient Nega-Rate Belleville disc spring sensing mechanism. Stable set points are not affected by system pressure changes. Operating ressure Data Adjustable Range Number Adjustable Set oint Range Increasing 9 To 50 " H 2 O 50 To 100 " H 2 O 100 To 150 " H 2 O Decreasing 5 To 46 " H 2 O 41 To 91 " H 2 O 88 To 138 " H 2 O Deadband (approximate) 4" H 2 O 9" H 2 O 12" H 2 O Maximum Recommended System ressure 100 psid 100 psid 100 psid roof ressure 150 psid 150 psid 150 psid Standard Specifications Electrical Snap action electrical switch assemblies, art Numbers & (Form C) and & (Form CC), are listed by Underwriters Laboratories, Inc., FM Approvals, CSA International and NCC (INMETRO). See the miscellaneous option N for additional listings. Electrical Connection 1/2 NT male conduit connection with VC insulated 18 AWG, 18 long leads ressure Connections 7/16-20 SAE Female Temperature Range* Ambient: - 30 F to +160 F (-34 C to +71 C) Media: - 30 F to +160 F (-34 C to +71 C) * Temperature limits change with O-ring selection. See Electrical Assembly specification sheet for Temperature Class Ratings. Shipping Weight Approximately 20 ounces Ordering Sequence Select desired option for each category OTIONS 1 Aluminum and stainless steel, Teflon coated polyimide diaphragm, Buna-N O-Rings 2 5" H2O decreasing to 50" H2O increasing 4 41" H2O decreasing to 100" H2O increasing 6 88" H2O decreasing to 150" H2O increasing C 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive 28 VDC;.5 amp resistive 125 VDC CC 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive 28 VDC;.5 amp resistive 125 VDC 6 Includes an explosion proof, hermetically-sealed electrical assembly. EX d IIC. Division 1 and 2, Class I, Groups A, B, C, and D; Class II, Groups E, F, and G. NEMA 4X, 7, and 9; I66. Leads are factory sealed and ressure Switches are Dual Seal Certified. A Epoxy paint exterior extra protection for severe environments B Viton O-Ring C ER O-Ring M Gold electrical contacts for extremely low current applications N ATEX and IECEx R 72" Electrical free leads I 3/4 NT conduit box with terminal strip (Groups C & D only, not available with N option) Special (Consult representative or factory) Non-catalog set point, deadband and/or proof pressure Explosion roof Hermetically Sealed (NEMA 4X, 7, 9 and 13) Ordering rocedure When factory presetting is desired, stipulate set point, increasing or decreasing Insert available option number or letter designation as required Example C 6 _ Series

105 Field Adjustable 5 to 150 Inch H 2 0 Series 151 Envelope Dimensions 7/16 1/2 7/16 FORM "C" (SDT) HIGH FORM "CC" (DDT) HIGH SCREW LOW BLK NC2 YEL C2 VIO NO2 SCREW LOW Basic rinciples of Design Neo-Dyn Industry Drive Valencia, CA tel: fax: AER0935_32 6/12 Specifications and dimensions subject to change.

106 Neo-Dyn Neo-Dyn Series 1528 Ultra Low Differential ressure Switch Ultra low adjustable differential pressure switch. Unique construction using efficient Nega-Rate Belleville disc spring for stable set points and high proof pressure. Explosion proof enclosure and wide range of wetted materials makes this switch especially well suited for hazardous or corrosive atmospheres. Operating ressure Data Adjustable Range Number Adjustable Set oint Range Increasing Deadband* (approximate) Maximum Recommended System ressure roof ressure 2 2" to 100" H 2 O Differential 1.5" H 2 O 15 psig Simul. or Hi over Low 100" H 2 O Low over Hi 100 SI Simul. or Hi over Low 15 SI Low over Hi *Deadband 50% wider with "CC" (DDT) s. Standard Specifications Electrical Snap action electrical switch assemblies, art Numbers & (Form C) and & (Form CC), are listed by Underwriters Laboratories, Inc., FM Approvals, CSA International and NCC (INMETRO). See the miscellaneous option N for additional listings. Electrical Connection 1/2 NT male conduit connection with VC insulated 18 AWG, 18 long leads ressure Connection High 1/2 NT Female Low 1/4 NT Female Temperature Range* Ambient: - 40 F to +180 F (-40 C to +82 C) Media: - 50 F to +250 F (-46 C to +121 C) *Temperature limits change with O-Ring selection. See Electrical Assembly specification sheet for Temperature Class Ratings. Concealed wrench flat adjustment with range scale Shipping Weight Approximately 4 pounds Order Option D Explosion roof Hermetically Sealed (NEMA 4X, 7, 9 and 13) Ordering Sequence Select desired option for each category OTIONS 2.5" H2O dec. (1.2 mb) to 100" H2O inc. (249 mb) C 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; CC 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; 6 Includes an explosion proof, hermetically-sealed electrical assembly. EX d IIC. Division 1 and 2, Class I, Groups A, B, C, and D; Class II, Groups E, F, and G. NEMA 4X, 7, and 9; I66. Leads are factory sealed and ressure Switches are Dual Seal Certified. A Epoxy paint exterior extra protection for severe environments D SIL approval and marking, per IEC61508 (includes FMEA report) I 3/4 NT conduit box with terminal strip (Groups C & D only, not available with N option) M Gold electrical contacts for extremely low current applications (1 Amp at 125 VAC; 1 Amp Res, 0.5 Amp Ind. at 28 VDC) N ATEX and IECEx R 72" Electrical free leads ort Material Stainless Steel High/Aluminum Low Stainless Steel High/Low Diaphragm 1 olyimide Stainless Steel 6 Tantalum 7 Hastelloy C O-Rings 2 Kalrez 3 Viton 5 ER 8 Buna-N Special (Consult representative or factory) Non-catalog adjustable range and/or set point, deadband and proof pressure Media temperature capabilities from -65 F to +400 F Ordering rocedure When factory presetting is desired, stipulate set point, increasing or decreasing and system pressure Insert available option number or letter designation as required Example CC6 _ 463 Series ort Material Diaphragm O-Rings

107 Field Adjustable.5" H 2 O to 100" H 2 O Series 152 Envelope Dimensions Low ressure ort ¼ NT (orientation as shown) Conduit Connection ½ NT High ressure ort ½ NT FORM "C" (SDT) HIGH FORM "CC" (DDT) HIGH LOW BLK YEL NC2 C2 VIO NO2 LOW Basic rinciples of Design Neo-Dyn Industry Drive Valencia, CA tel: fax: AER0935_34 7/13 Specifications and dimensions subject to change.

108 Neo-Dyn Neo-Dyn Series 160 Differential ressure Switch Mid-range, adjustable differential pressure switch. Efficient Nega-Rate Belleville disc spring sensing mechanism for stable set points during system pressure changes. Hermetically sealed, explosion-proof electrical assembly well suited for hazardous or explosive environments. Operating ressure Data Adjustable Range Number All values given in psid. Standard Specifications Electrical Snap action electrical switch assemblies, art Numbers & (Form C) and & (Form CC), are listed by Underwriters Laboratories, Inc., FM Approvals, CSA International and NCC (INMETRO). See the miscellaneous option N for additional listings. Electrical Connection 1/2 NT male conduit connection with VC insulated 18 AWG, 18" long leads ressure Connection 1/4 NT Female Temperature Range* Ambient: - 40 F to +180 F (-40 C to +82 C) Media: - 40 F to +250 F (-40 C to +121 C) *Temperature limits change with O-Ring selection. See Electrical Assembly specification sheet for Temperature Class Ratings. Concealed wrench flat adjustment with range scale Shipping Weight Approximately 3.5 pounds Order Option D Adjustable Set oint Range Increasing Decreasing 1.1 to to 18 5 to to 110 Explosion roof Hermetically Sealed (NEMA 4X, 7, 9 and 13).75 to to to to 104 Deadband (approximate) Ordering Sequence Select desired option for each category Ordering rocedure When factory presetting is desired, stipulate set point, increasing or decreasing and system pressure Insert available option number or letter designation as required 3 6 Maximum Recommended System ressure OTIONS 1 Aluminum port and body, Teflon coated polyimide diaphragm, Buna-N O-Rings and stainless steel 4 Stainless steel, Teflon coated polyimide diaphragm and Buna-N O-Rings 2.75 psid dec. to 15 psid inc. (0.1 bar dec. to 1.0 bar inc.) 4.3 psid dec. to 18 psid inc. (0.0 bar dec. to 1.2 bar inc.) 6 2 psid dec. to 60 psid inc. (0.1 bar dec. to 4.1 bar inc.) 7 49 psid dec. to 110 psid inc. (3.4 bar dec. to 7.6 bar inc.) C 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; CC 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; Example C 6_ Series roof ressure 500 Hi/Low 200 Low/Hi 1000 Hi/Low 400 Low/Hi 1000 Hi/Low 400 Low/Hi 1000 Hi/Low 400 Low/Hi 6 Includes an explosion proof, hermetically-sealed electrical assembly. EX d IIC. Division 1 and 2, Class I, Groups A, B, C, and D; Class II, Groups E, F, and G. NEMA 4X, 7, and 9; I66. Leads are factory sealed and ressure Switches are Dual Seal Certified.. A Epoxy paint exterior extra protection for severe environments B Viton O-Ring C ER O-Ring D SIL approval and marking, per IEC61508 (includes FMEA report) I 3/4 NT conduit box with terminal strip (Groups C & D only, not available with N option) M Gold electrical contacts for extremely low current applications (1 Amp at 125 VAC; 1 Amp Res, 0.5 Amp Ind. at 28 VDC) N ATEX and IECEx with CE Mark R 72" Electrical free leads S Stainless steel diaphragm No low over high capability (Ranges 2 & 4 and 4 only) Special (Consult representative or factory) Non-catalog adjustable range and/or set point, deadband and proof pressure Media temperature capability from -65 F to +350 F Chemical seals installed Optional orientation of Low ressure ort

109 Field Adjustable.3 to 110 psid Series 160 Envelope Dimensions 1.12 Free Leads 18 AWG 18" Long.37 Low ressure ort ¹ v NT ¼ NT High High ressure ort ¹ v NT ¼ NT 2.85 Conduit Connection ¹ x NT ½ NT Dia. Mtg. Holes (2 places) 2X FORM "C" (SDT) HIGH FORM "CC" (DDT) HIGH LOW BLK YEL NC2 C2 VIO NO2 LOW Basic rinciples of Design 2 and 4 Snap Action Electrical All Stainless Element Steel Construction Electrical Assembly Negative Rate Belleville Disc Spring Actuator Low ressure ort ressure late High ressure ort 6 and 7 Minimum Bearing oints Low ressure ort ressure late High ressure ort Glass to Metal Sealed Header Motion Transfer Arm Diaphragm O-Rings O-Rings Negative Rate Belleville Disc Spring Diaphragm Neo-Dyn Industry Drive Valencia, CA tel: fax: AER0935_36 7/13 Specifications and dimensions subject to change.

110 Neo-Dyn Neo-Dyn Series 151 Differential ressure Switch Low range adjustable differential pressure switch compact design features efficient Nega-Rate Belleville disc spring sensing mechanism. Stable set points are not affected by system pressure changes. Operating ressure Data Adjustable Range Number Adjustable Set oint Range Increasing 9 To 50 " H 2 O 50 To 100 " H 2 O 100 To 150 " H 2 O Decreasing 5 To 46 " H 2 O 41 To 91 " H 2 O 88 To 138 " H 2 O Deadband (approximate) 4" H 2 O 9" H 2 O 12" H 2 O Maximum Recommended System ressure 100 psid 100 psid 100 psid roof ressure 150 psid 150 psid 150 psid Standard Specifications Electrical Snap action electrical switch listed by Underwriters Laboratories, Inc., Factory Mutual and CSA International Electrical Connection 1/2 NT male conduit connection with VC insulated 18 AWG, 18 long leads ressure Connections 7/16-20 SAE Female Temperature Range* Ambient: - 30 F to +160 F (-34 C to +71 C) Media: - 30 F to +160 F (-34 C to +71 C) * Temperature limits change with O-ring selection. See Electrical Assembly specification sheet for Temperature Class Ratings. Shipping Weight Approximately 20 ounces Ordering Sequence Select desired option for each category OTIONS 1 Aluminum and stainless steel, Teflon coated polyimide diaphragm, Buna-N O-Rings 2 5" H2O decreasing to 50" H2O increasing 4 41" H2O decreasing to 100" H2O increasing 6 88" H2O decreasing to 150" H2O increasing C 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive 28 VDC;.5 amp resistive 125 VDC CC 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive 28 VDC;.5 amp resistive 125 VDC 6 Explosion proof, hermetically-sealed electrical assembly, EX d IIC. art Numbers & (Form C) and & (Form CC). Agency listings include Underwriters Laboratories, Inc., CSA International, Factory Mutual, and Inmetro. Division 1 and 2, Class I, Groups A, B, C, and D; Class II, Groups E, F, and G. NEMA 4X, 7, and 9; I66. Leads are factory sealed and ressure Switches are Dual Seal Certified. A Epoxy paint exterior extra protection for severe environments B Viton O-Ring C ER O-Ring M Gold electrical contacts for extremely low current applications N ATEX and IECEx R 72" Electrical free leads I 3/4 NT conduit box with terminal strip (Groups C & D only, not available with N option) Special (Consult representative or factory) Non-catalog set point, deadband and/or proof pressure Explosion roof Hermetically Sealed (NEMA 4X, 7, 9 and 13) Ordering rocedure When factory presetting is desired, stipulate set point, increasing or decreasing Insert available option number or letter designation as required Example C 6 _ Series

111 Field Adjustable 5 to 150 Inch H 2 0 Series 151 Envelope Dimensions 7/16 1/2 7/16 FORM "C" (SDT) HIGH FORM "CC" (DDT) HIGH SCREW LOW BLK NC2 YEL C2 VIO NO2 SCREW LOW Basic rinciples of Design Neo-Dyn Industry Drive Valencia, CA tel: fax: AER0935_32 6/12 Specifications and dimensions subject to change.

112 Neo-Dyn Neo-Dyn Series 162 Differential ressure Switch Adjustable high pressure differential switch. Rugged construction with efficient Nega-Rate Belleville disc spring sensing mechanism. Maintains set point at high system pressure. Available in all stainless steel construction with hermetically sealed electrical assembly for corrosive atmospheres. Operating ressure Data Adjustable Range Number Adjustable Set oint Range Increasing 6 to to to to to 1000 Decreasing 1 to to to to to 900 Deadband (approximate) Maximum Recommended System ressure Simultaneous roof ressure High/Low Low/High All values given in psid. Standard Specifications Electrical Snap action electrical switch assemblies, art Numbers & (Form C) and & (Form CC), are listed by Underwriters Laboratories, Inc., FM Approvals, CSA International and NCC (INMETRO). See the miscellaneous option N for additional listings. Electrical Connection 1/2 NT male conduit connection with VC insulated 18 AWG, 18" long leads ressure Connections 1/4 NT Female Temperature Range* Ambient: - 40 F to +180 F (-40 C to +82 C) Media: - 40 F to +300 F (-40 C to +149 C) *Temperature limits change with O-Ring selection. See Electrical Assembly specification sheet for Temperature Class Ratings. External 1/2" hex head Note: Turn clockwise to increase set point; approximately 24 turns through range Shipping Weight Aluminum: Approximately 3 lbs Stainless Steel: Approximately 7 lbs Ordering Sequence Select desired option for each category OTIONS 1 Aluminum port, Teflon coated polyimide diaphragm, steel, and Buna-N O-Ring 4 Stainless steel ports, Teflon coated polyimide diaphragm and Buna-N O-Ring 2 1 psid dec. to 50 psid inc. (0.1 bar dec. to 3.4 bar inc.) 4 10 psid dec. to 90 psid inc. (0.7 bar dec. to 6.2 bar inc.) 6 10 psid dec. to 200 psid inc. (0.7 bar dec. to 13.8 bar inc.) psid dec. to 350 psid inc. (10.3 bar dec. to 24.1 bar inc.) psid dec. to 1000 psid inc. (15.5 bar dec. to 69.0 bar inc.) C 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; CC 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; 6 Includes an explosion proof, hermetically-sealed electrical assembly. EX d IIC. Division 1 and 2, Class I, Groups A, B, C, and D; Class II, Groups E, F, and G. NEMA 4X, 7, and 9; I66. Leads are factory sealed and ressure Switches are Dual Seal Certified. A Epoxy paint exterior extra protection for severe environments B Viton O-Ring C ER O-Ring D SIL approval and marking, per IEC61508 (includes FMEA report) I 3/4 NT conduit box with terminal strip (Groups C & D only, not available with N option) M Gold electrical contacts for extremely low current applications (1 Amp at 125 VAC; 1 Amp Res, 0.5 Amp Ind. at 28 VDC) N ATEX and IECEx with CE Mark R 72" Electrical free leads Special (Consult representative or factory) Non-catalog adjustable range and/or set point, deadband and proof pressure Chemical seals installed Order Option D Ordering rocedure Example Explosion roof Hermetically Sealed (NEMA 4X,7, 9 and 13) When factory presetting is desired, stipulate set point, increasing or decreasing, and system pressure Insert available option number or letter designation as required C 6_ Series

113 Field Adjustable 1 to 1000 psid Series 162 Envelope Dimensions Free Leads 18" Long 18 AWG 1.90 Approx Conduit Connection ¹ ₂ NT External ¹ ₂" Hex 2.13 Low ressure ort ¹ ₄ NT High ressure ort ¹ ₄ NT ¹ ₄ - 20 UNC - 3B x.25 Deep Mtg. Holes (2 places) FORM "C" (SDT) HIGH FORM "CC" (DDT) HIGH LOW BLK YEL NC2 C2 VIO NO2 LOW Neo-Dyn Industry Drive Valencia, CA tel: fax: AER0935_37 7/13 Specifications and dimensions subject to change.

114 GENERAL UROSE TEMERATURE SWITCHES NEMA 4, 4X & 13 General urpose Weather roof Adjustable 100T Series Direct Mount TC Series Remote Mount General urpose Weather roof Adjustable 132T Series Direct Mount TC Series Remote Mount HAZARDOUS AREA TEMERATURE SWITCHES NEMA 7 & 9 Hermetically Sealed/Explosion roof Adjustable 100T Series Direct Mount TC Series Remote Mount Hermetically Sealed/Explosion roof Adjustable 132T Series Direct Mount TC Series Remote Mount

115 Neo-Dyn Neo-Dyn Series 100T Temperature Switch/Internal Direct mount adjustable temperature switch with efficient Nega-Rate Belleville spring mechanism and saturated vapor sensor for quick response. Operating Temperature Data Adjustable Range Adjustable Set oint Range Deadband (approx) Bottom/Top roof Temperature Number B D F H J Increasing F -50 to to to to to +500 Decreasing F -69 to to to to to +495 F 19/3 23/3 25/3 30/5 30/5 C 11 / 2 13 / 2 14 / 2 17 / 3 17 / 3 F C Deadband decreases as the adjustable set point is increased. For narrow deadband select set point in upper half of adjustable range. Standard Specifications Electrical Snap action electrical switch recognized by Underwriters Laboratories, Inc. and CSA International Electrical Connection 1/2 NT female conduit connection with terminal block rocess Connection 1/2 NT Male Direct mount Temperature Range Ambient: - 40 F to +180 F (-40 C to +82 C) System ressure 1500 psig maximum roof ressure 2250 psig Concealed wrench flat adjustment with range scale Shipping Weight Approximately 3 pounds Order Option D Ordering Sequence Select desired option for each category OTIONS 3 Steel port with stainless steel probe, Viton seal NOTE: Range J uses Teflon seal B -69 F dec. to +65 F inc. D +7 F dec. to +175 F inc. F +70 F dec. to +250 F inc. H +145 F dec. to +360 F inc. J +305 F dec. to +500 F inc. (-56 C dec. to (-14 C dec. to (21 C dec. to (63 C dec. to (152 C dec. to 18 C inc.) 79 C inc.) 121 C inc. ) 182 C inc.) 260 C inc.) C 15 amp at 125 or 250 VAC; 1/8, hp at 125 VAC; 1/4 hp at 250 VAC;.5 amp resistive,.04 amp inductive at 125 VDC CC 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive 28 at VDC; Z 15 amp at 125 or 250 VAC; 1/4 hp at 125 VAC; 1/2 hp at 250 VAC; 1 amp resistive,.5 amp inductive at 125 VDC 3 Meets or exceeds the requirements of NEMA Type 3, 3R, 3S, 4, 4X and 13 A Epoxy paint exterior extra protection for severe environments D SIL approval and marking, per IEC61508 (includes FMEA report) J Annealed stainless steel port screws for H 2 S environments L Neon indicator light 115 VAC M Gold electrical contacts for extremely low current applications 5-in Brad Harrison connector (Reduce AC electrical rating to 8 amps) (Not for CC3 Electrical) W Stainless steel screws exterior X CE Mark Special (Consult representative or factory) Thermowells Non-catalog adjustable range and/or set point and deadband Optional probe lengths available Weather roof (NEMA 4 and 13) Ordering rocedure When factory presetting is desired, stipulate set point, increasing or decreasing Insert available option letter designation as required Example 100T 3BCC3_ Series (specify)

116 Field Adjustable -69 F to +500 F Series 100T Envelope Dimensions Conduit Connection ½ NT FORM "C" (SDT) T FORM "CC" (DDT) T FORM "Z" (DOUBLE BREAK) T NC NC BLK SCREW BLK YEL VIO NC2 C2 NO2 NO SCREW NO VIO SCREW Basic rinciples of Design Neo-Dyn Industry Drive Valencia, CA tel: fax: AER0935_5 7/13 Specifications and dimensions subject to change.

117 Neo-Dyn Neo-Dyn Series 100TC Temperature Switch/Internal Remote mount adjustable temperature switch with efficient Nega-Rate Belleville spring mechanism and saturated vapor sensor for quick response and narrow deadband. Operating Temperature Data Adjustable Range Adjustable Set oint Range Deadband (approx) Bottom/Top roof Temperature Number B D F H J L Increasing F -50 to to to to to to +720 Decreasing F -69 to to to to to to +714 F 19/3 23/3 25/3 30/5 30/5 40/6 C 11 / 2 13 / 2 14 / 2 17 / 3 17 / 3 22 / 3 F * 900* C Deadband decreases as the adjustable set point is increased. For narrow deadband select set point in upper half of adjustable range. *Thermowell required for temperatures above 500 F. Standard Specifications Electrical Snap action electrical switch recognized by Underwriters Laboratories, Inc. and CSA International Electrical Connection 1/2 NT female conduit connection with terminal block rocess Connection 1/2 NT Male Remote mount Stainless steel 6' capillary with armor jacket, 10" minimum bendable tubing and 1/2" adjustable gland nut. Optional capillary lengths available. Temperature Range Ambient: - 40 F to +180 F (-40 C to +82 C) System ressure 1500 psig maximum roof ressure 2250 psig Concealed wrench flat adjustment with range scale Shipping Weight Approximately 5 pounds Order Option D Ordering Sequence Select desired option for each category OTIONS series stainless steel, graphite filled non-asbestos packing B -69 F dec. to +65 F inc. (-56 C dec. to 18 C inc.) D +7 F dec. to +175 F inc. (-14 C dec. to 79 C inc.) F +70 F dec. to +250 F inc. (21 C dec. to 121 C inc.) H +145 F dec. to +360 F inc. (63 C dec. to 182 C inc.) J +305 F dec. to +500 F inc. (152 C dec. to 260 C inc.) L +445 F dec. to +720 F inc. (229 C dec. to 382 C inc.) C 15 amp at 125 or 250 VAC; 1/8 hp at 125 VAC; 1/4 hp at 250 VAC;.5 amp resistive,.04 amp inductive at 125 VDC CC 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; Z 15 amp at 125 or 250 VAC; 1/4 hp at 125 VAC; 1/2 hp at 250 VAC; 1 amp resistive,.5 amp inductive at 125 VDC 3 Meets or exceeds the requirements of NEMA Type 3, 3R, 3S, 4, 4X and 13 A Epoxy paint exterior extra protection for severe environments D SIL approval and marking, per IEC61508 (includes FMEA report) J Annealed stainless steel port screws for H 2 S environments L Neon indicator light 115 VAC M Gold electrical contacts for extremely low current applications 5-in Brad Harrison connector (Reduce AC electrical rating to 8 amps) (Not for CC3 Electrical) W Stainless steel screws exterior X CSA Certified and CE Mark Optional Capillary Lengths 10', 15', 20' and 25' lengths available (insert appropriate number at end of model number see Example) Special (Consult representative or factory) Thermowells Non-catalog adjustable range and/or set point and deadband Weather roof (NEMA 4 and 13) Ordering rocedure When factory presetting is desired, stipulate set point, increasing or decreasing Insert available option number or letter designation as required Example 100TC 5BCC3 Series Optional Capillary Length

118 Field Adjustable -69 F to +925 F Series 100TC Envelope Dimensions Dia. Mtg. Holes (2 places) Approx. Conduit Connection Z\x NT 72" Flexible 300 Series Stainless Steel Armor Adjustable Gland Nut Z\x NT FORM "C" (SDT) T FORM "CC" (DDT) T FORM "Z" (DOUBLE BREAK) T NC NC BLK SCREW BLK YEL VIO NC2 C2 NO2 NO SCREW NO VIO SCREW Basic rinciples of Design Snap Action Electrical Element Terminal Strip Actuator Diaphragm Minimum Bearing oints ressure late Negative Rate Belleville Disc Spring Bendable 316 Stainless Steel Extension Neo-Dyn Industry Drive Valencia, CA tel: fax: AER0935_6 7/13 Specifications and dimensions subject to change.

119 Neo-Dyn Neo-Dyn Series 132T Temperature Switch/Internal Compact, adjustable, direct mount temperature switch featuring the efficient Nega-Rate Belleville disc spring for set point stability and vibration resistance. Operating Temperature Data Adjustable Adjustable Set oint Range Deadband (approx) Bottom/Top roof Temperature Range B D F H J L N Increasing F -50 to to to to to to to +395 Decreasing F -69 to to to to to to to +391 F 19/4 23/4 25/4 26/6 29/6 24/4 27/4 C 11 / 2 13 / 2 14 / 2 14 / 3 16 / 3 13 / 2 15 / 2 F C Deadband decreases as the adjustable set point is increased. For narrow deadband select set point in upper half of adjustable range. Standard Specifications Electrical Snap action electrical switch recognized by Underwriters Laboratories, Inc. and CSA International Electrical Connection 1/2 NT male conduit connection with VC insulated 18 AWG, 18" long leads rocess Connection 1/2 NT Male Direct mount System ressure 1500 psig maximum roof ressure 2250 psig Internal, slotted adjustment nut with range scale Temperature Range Ambient: - 40 F to +180 F (-40 C to +82 C) Shipping Weight Approximately 2.5 pounds Order Option D Ordering Sequence Select desired option for each category OTIONS Series stainless steel port and probe assembly, Teflon seal B -69 F dec. to +30 F inc. D +7 F dec. to +125 F inc. F +70 F dec. to +200 F inc. H +89 F dec. to +230 F inc. J +146 F dec. to +300 F inc. L +236 F dec. to +360 F inc. N +263 F dec. to +395 F inc. (-56 C dec. to -1 C inc.) (-14 C dec. to 52 C inc.) (21 C dec. to 93 C inc.) (32 C dec. to 110 C inc.) (63 C dec. to 149 C inc.) (113 C dec. to 182 C inc.) (128 C dec. to 202 C inc.) C 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; CC 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; 3 Meets or exceeds the requirements of NEMA Type 3, 3R, 3S, 4, 4X and 13 A Epoxy paint exterior extra protection for severe environments D SIL approval and marking, per IEC61508 (includes FMEA report) I 3/4 NT conduit box with terminal strip J Annealed stainless steel port screws for H 2 S environments M Gold electrical contacts for extremely low current applications R 72" Electrical free leads X CE Mark Special (Consult representative or factory) Thermowells Non-catalog adjustable range and/or set point and deadband Non-standard probe lengths Ordering rocedure Example Weather roof (NEMA 4 and 13) When factory presetting is desired, stipulate set point, increasing or decreasing Insert available option letter designation as required 132T 4BCC3_ Series

120 Field Adjustable -69 F to +395 F Series 132T Envelope Dimensions SQ Cover Free Leads 18 AWG 18" Long.25 ressure ort ressure ¹ x NT ort ½ NT.209 Dia. Mtg. Holes (2 places) Conduit Connection ¹ x ½ NT NT FORM "C" (SDT) T FORM "CC" (DDT) T (X-Option) BLK YEL NC2 C2 VIO NO2 Basic rinciples of Design aá~éüê~öã Temperature robe Negative Rate Belleville Disc Spring Snap Action Electrical Element mêéëëìêé=mä~íé Actuator Minimum Bearing oints Neo-Dyn Industry Drive Valencia, CA tel: fax: AER0935_26 7/13 Specifications and dimensions subject to change.

121 Neo-Dyn Neo-Dyn Series 132TC Temperature Switch/Internal Compact, adjustable, temperature switch featuring the efficient Nega-Rate Belleville disc spring for set point stability and vibration resistance. Comes with capillary for remote mount up to 25 feet. Operating Temperature Data Adjustable Adjustable Set oint Range Deadband (approx) Bottom/Top roof Temperature Range Increasing F Decreasing F F C F C B -50 to to /4 11 / D +30 to to /4 13 / F +95 to to /4 14 / H +115 to to /6 14 / J +175 to to /6 16 / L +260 to to /4 13 / N +290 to to /4 15 / to to /4 15 / 2 600* 315 R +485 to to +646* 40/9 22 / 5 750* 399 Deadband decreases as the adjustable set point is increased. For narrow deadband select set point in upper half of adjustable range. *Thermowell required for temperatures above 500 F. Standard Specifications Electrical Snap action electrical switch recognized by Underwriters Laboratories, Inc. and CSA International Electrical Connection 1/2 NT male conduit connection with VC insulated 18 AWG, 18" long leads rocess Connection 1/2 NT Male Remote mount Stainless steel 6' capillary with armor jacket, 10" minimum bendable tubing and 1/2" adjustable gland nut. Optional capillary lengths available. System ressure 1500 psig maximum roof ressure 2250 psig Internal, slotted adjustment nut with range scale Temperature Range Ambient: - 40 F to +180 F (-40 C to +82 C) Shipping Weight Approximately 3.5 pounds Order Option D Ordering Sequence Select desired option for each category OTIONS series stainless steel, graphite filled non-asbestos packing B -69 F dec. to +30 F inc. D +7 F dec. to +125 F inc. F +70 F dec. to +200 F inc. H +89 F dec. to +230 F inc. J +146 F dec. to +300 F inc. L +236 F dec. to +360 F inc. N +263 F dec. to +395 F inc F dec. to +480 F inc. R +445 F dec. to +655 F inc. (-56 C dec. to -1 C inc.) (-14 C dec. to 52 C inc.) (21 C dec. to 93 C inc.) (23 C dec. to 110 C inc.) (63 C dec. to 149 C inc.) (113 C dec. to 182 C inc.) (128 C dec. to 202 C inc.) (170 C dec. to 249 C inc.) (229 C dec. to 346 C inc.) C 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; CC 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; 3 Meets or exceeds the requirements of NEMA Type 3, 3R, 3S, 4, 4X and 13 A Epoxy paint exterior extra protection for severe environments D SIL approval and marking, per IEC61508 (includes FMEA report) I 3/4 NT conduit box with terminal strip J Annealed stainless steel port screws for H 2 S environments M Gold electrical contacts for extremely low current applications R 72" Electrical free leads X CE Mark Optional Capillary Lengths 10', 15', 20' and 25' lengths available (insert appropriate number at end of model number see Example) Special (Consult representative or factory) Thermowells Non-catalog adjustable range and/or set point and deadband Weather roof (NEMA 4 and 13) Ordering rocedure When factory presetting is desired, stipulate set point, increasing or decreasing Insert available option number or letter designation as required Example 132TC 5BCC3 Series Optional Capillary Length

122 Field Adjustable -69 F to +655 F Series 132TC Envelope Dimensions Adjustable Gland Nut 1/2 Adjustable NT Gland Nut Z\xNT Bendable Stainless Steel Extension SQ Cover Free Leads 18 AWG 18" Long Dia. Mtg. Holes (2 places) Conduit Connection Conduit Connectio 1/2 Z\xNT NT FORM "C" (SDT) T FORM "CC" (DDT) T (X-Option) BLK NC2 YEL C2 VIO NO2 Basic rinciples of Design Flexible 300 Series Stainless Steel Armor Negative Rate Belleville Disc Spring Snap Action Electrical Element Actuator Minimum Bearing oints Neo-Dyn Industry Drive Valencia, CA tel: fax: AER0935_27 7/13 Specifications and dimensions subject to change.

123 Neo-Dyn Neo-Dyn Series 100T Temperature Switch/Internal Direct mount adjustable temperature switch for use in hazardous areas. Utilizes efficient Nega-Rate Belleville spring mechanism and saturated vapor sensor for quick response and narrow deadband. Operating Temperature Data Adjustable Range Number B D F H J Adjustable Set oint Range Increasing F -50 to to to to to +500 Decreasing F -69 to to to to to +495 Deadband (approx) Bottom/Top F C F C 19/3 23/3 25/3 30/5 30/5 11 / 2 13 / 2 14 / 2 17 / 3 17 / Deadband decreases as the adjustable set point is increased. For narrow deadband select set point in upper half of adjustable range. roof Temperature Standard Specifications Electrical Snap action electrical switch assemblies, art Numbers & (Form C) and & (Form CC), are listed by Underwriters Laboratories, Inc., FM Approvals, CSA International and NCC (INMETRO). See the miscellaneous option N for additional listings. Electrical Connection 1/2 NT male conduit connection with VC insulated 18 AWG, 18" long leads ressure Connection 1/2 NT Male Direct mount Temperature Range Ambient: - 40 F to +180 F (-40 C to +82 C) See Electrical Assembly specification sheet for Temperature Class Ratings. System ressure 1500 psig maximum roof ressure 2250 psig Concealed wrench flat adjustment with range scale Shipping Weight Approximately 3 pounds Ordering Sequence Select desired option for each category OTIONS 3 Steel port with stainless steel probe, Viton seal NOTE: Range J uses Teflon seal B -69 F dec. to +65 F inc. D +7 F dec. to +175 F inc. F +70 F dec. to +250 F inc. H +145 F dec. to +360 F inc. J +305 F dec. to +500 F inc. (-56 C dec. to (-14 C dec. to (21 C dec. to (63 C dec. to (152 C dec. to 18 C inc.) 79 C inc. ) 121 C inc.) 182 C inc.) 260 C inc.) C 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; CC 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; 6 Includes an explosion proof, hermetically-sealed electrical assembly. EX d IIC. Division 1 and 2, Class I, Groups A, B, C, and D; Class II, Groups E, F, and G. NEMA 4X, 7, and 9; I66. Leads are factory sealed and ressure Switches are Dual Seal Certified. A Epoxy paint exterior extra protection for severe environments D SIL approval and marking, per IEC61508 (includes FMEA report) I 3/4 NT conduit box with terminal strip (Groups C & D only, not available with N option) J Annealed stainless steel port screws for H 2 S environments M Gold electrical contacts for extremely low current applications (1 Amp at 125 VAC; 1 Amp Res, 0.5 Amp Ind. at 28 VDC) N ATEX and IECEx with CE Mark R 72" Electrical free leads W Stainless steel screws exterior Special (Consult representative or factory) Thermowells Non-catalog adjustable range and/or set point and deadband Order Option D Explosion roof Hermetically Sealed (NEMA 4X, 7, 9 and 13) Ordering rocedure When factory presetting is desired, stipulate set point, increasing or decreasing Insert available option letter designation as required Example 100T 3BCC6_ Series

124 Field Adjustable -69 F to +500 F Series 100T Envelope Dimensions Conduit Connection ¹ x ½ NT rocess Connection ¹ x ½ NT NT.265 Dia. Mtg. Holes (2 places) FORM "C" (SDT) T FORM "CC" (DDT) T BLK NC2 YEL C2 VIO NO2 Basic rinciples of Design All Stainless Steel Construction Electrical Assembly Glass to Metal Sealed Header Snap Action Electrical Element Actuator Diaphragm Minimum Bearing oints Temperature robe Motion Transfer Arm ressure late Negative Rate Belleville Disc Spring Neo-Dyn Industry Drive Valencia, CA tel: fax: AER0935_8 7/13 Specifications and dimensions subject to change.

125 Neo-Dyn Neo-Dyn Series 100TC Temperature Switch/Internal Remote mount adjustable temperature switch for use in hazardous areas. Utilizes the efficient Nega-Rate Belleville spring mechanism and saturated vapor sensor for quick response. Operating Temperature Data Adjustable Range Adjustable Set oint Range Deadband (approx) Bottom/Top roof Temperature Number B D F H J L Increasing F -50 to to to to to to +720 Decreasing F -69 to to to to to to +714 F 19/3 23/3 25/3 30/5 30/5 40/6 C 11 / 2 13 / 2 14 / 2 17 / 3 17 / 3 22 / 3 F * 900* C Deadband decreases as the adjustable set point is increased. For narrow deadband select set point in upper half of adjustable range. *Thermowell required for temperatures above 500 F. Standard Specifications Electrical Snap action electrical switch assemblies, art Numbers & (Form C) and & (Form CC), are listed by Underwriters Laboratories, Inc., FM Approvals, CSA International and NCC (INMETRO). See the miscellaneous option N for additional listings. Electrical Connection 1/2 NT male conduit connection with VC insulated 18 AWG, 18" long leads rocess Connection 1/2 NT Male Remote mount. Stainless steel 6' capillary with armor jacket, 10" minimum bendable tubing and 1/2" adjustable gland nut. Optional capillary lengths available. Temperature Range Ambient: - 40 F to +180 F (-40 C to +82 C) See Electrical Assembly specification sheet for Temperature Class Ratings. System ressure: 1500 psig max. roof ressure: 2250 psig Concealed wrench flat adjustment with range scale Shipping Weight: Approximately 5 pounds Ordering Sequence Select desired option for each category OTIONS stainless steel, graphite filled non-asbestos packing B -69 F dec. to +65 F inc. D +7 F dec. to +175 F inc. F +70 F dec. to +250 F inc. H +145 F dec. to +360 F inc. J +305 F dec. to +500 F inc. L +445 F dec. to +720 F inc. (-56 C dec. to (-14 C dec. to (21 C dec. to (63 C dec. to (152 C dec. to (229 C dec. to 18 C inc.) 79 C inc.) 121 C inc.) 182 C inc.) 260 C inc.) 382 C inc.) C 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; CC 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; 6 Includes an explosion proof, hermetically-sealed electrical assembly. EX d IIC. Division 1 and 2, Class I, Groups A, B, C, and D; Class II, Groups E, F, and G. NEMA 4X, 7, and 9; I66. Leads are factory sealed and ressure Switches are Dual Seal Certified. A Epoxy paint exterior extra protection for severe environments D SIL approval and marking, per IEC61508 (includes FMEA report) I 3/4 NT conduit box with terminal strip (Groups C & D only, not available with N option) J Annealed stainless steel port screws for H 2 S environments M Gold electrical contacts for extremely low current applications (1 Amp at 125 VAC; 1 Amp Res, 0.5 Amp Ind. at 28 VDC) N ATEX and IECEx with CE Mark R 72" Electrical free leads W Stainless steel screws exterior Optional Capillary Lengths 10', 15', 20' and 25' lengths available (insert appropriate number at end of model number see Example) Special (Consult representative or factory) Thermowells Non-catalog adjustable range and/or set point and deadband Order Option D Explosion roof Hermetically Sealed (NEMA 4X, 7, 9 and 13) Ordering rocedure When factory presetting is desired, stipulate set point, increasing or decreasing Insert available option number or letter designation as required Example 100TC 5BCC6 Series Optional Capillary Length

126 Field Adjustable -69 F to +925 F Series 100TC Envelope Dimensions Conduit Connection Z\x NT Approx. Flexible 300 Series Stainless Steel Armor Adjustable Gland Nut Z\x NT FORM "C" (SDT) T FORM "CC" (DDT) T BLK NC2 YEL C2 VIO NO2 Basic rinciples of Design All Stainless Steel Construction Electrical Assembly Glass to Metal Sealed Header Snap Action Electrical Element Actuator Diaphragm Minimum Bearing oints Motion Transfer Arm ressure late Negative Rate Belleville Disc Spring Bendable Stainless Steel Extension Neo-Dyn Industry Drive Valencia, CA tel: fax: AER0935_7 7/13 Specifications and dimensions subject to change.

127 Neo-Dyn Neo-Dyn Series 132T Temperature Switch/Internal Compact, adjustable, direct mount temperature switch featuring the efficient Nega-Rate Belleville disc spring for set point stability and vibration resistance. Available with all stainless steel exterior and interior construction together with a hermetically sealed, explosion-proof electrical assembly. Ideally suited for applications involving hazardous and corrosive medias or environments. Operating Temperature Data Adjustable Adjustable Set oint Range Deadband (approx) Bottom/Top roof Temperature Range Increasing F Decreasing F F C F C B -50 to to /4 11 / D +30 to to /4 13 / F +95 to to /4 14 / H +115 to to /6 14 / J +175 to to /6 16 / L +260 to to /4 13 / N +290 to to /4 15 / Deadband decreases as the adjustable set point is increased. For narrow deadband select set point in upper half of adjustable range. Standard Specifications Electrical Snap action electrical switch assemblies, art Numbers & (Form C) and & (Form CC), are listed by Underwriters Laboratories, Inc., FM Approval, CSA International and NCC (INMETRO). See the miscellaneous option N for additional listings. Electrical Connection 1/2 NT male conduit connection with VC insulated 18 AWG, 18" long leads rocess Connection 1/2 NT Male Direct mount System ressure 1500 psig maximum roof ressure 2250 psig Internal, slotted adjustment nut with range scale Temperature Range Ambient: - 40 F to +180 F (-40 C to +82 C) See Electrical Assembly specification sheet for Temperature Class Ratings. Shipping Weight Approximately 2.5 pounds Ordering Sequence Select desired option for each category OTIONS Series stainless steel port and probe assembly, Teflon seal B -69 F dec. to +30 F inc. (-56 C dec. to -1 C inc.) D +7 F dec. to +125 F inc. (-14 C dec. to 52 C inc.) F +70 F dec. to +200 F inc. (21 C dec. to 93 C inc.) H +89 F dec. to +230 F inc. (32 C dec. to 110 C inc. ) J +146 F dec. to +300 F inc. (63 C dec. to 149 C inc. ) L +236 F dec. to +360 F inc. (113 C dec. to 182 C inc.) N +263 F dec. to +395 F inc. (128 C dec. to 202 C inc.) C 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; CC 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; 6 Includes an explosion proof, hermetically-sealed electrical assembly. EX d IIC. Division 1 and 2, Class I, Groups A, B, C, and D; Class II, Groups E, F, and G. NEMA 4X, 7, and 9; I66. Leads are factory sealed and ressure Switches are Dual Seal Certified. A Epoxy paint exterior extra protection for severe environments D SIL approval and marking, per IEC61508 (includes FMEA report) H 316 stainless steel body I 3/4 NT conduit box with terminal strip (Groups C & D only, not available with N option) J Annealed stainless steel port screws for H 2 S environments M Gold electrical contacts for extremely low current applications N ATEX and IECEx with CE Mark R 72" Electrical free leads Special (Consult representative or factory) Thermowells Non-catalog adjustable range and/or set point and deadband Order Option D Ordering rocedure Example Explosion roof Hermetically Sealed (NEMA 4X, 7, 9 and 13) When factory presetting is desired, stipulate set point, increasing or decreasing Insert available option letter designation as required 132T 4BCC6_ Series

128 Field Adjustable -69 F to +395 F Series 132T Envelope Dimensions SQ Cover Free Leads 18 AWG 18" Long.25 ressure ort ort ¹ x 1/2 NT.209 Dia. Mtg. Holes (2 places) Conduit Connection 1/2 ¹ x NT FORM "C" (SDT) T FORM "CC" (DDT) T BLK NC2 YEL C2 VIO NO2 Basic rinciples of Design aá~éüê~öã Temperature robe Negative Rate Belleville Disc Spring Motion Transfer Arm All Stainless Steel Construction Electrical Assembly mêéëëìêé=mä~íé Actuator Minimum Bearing oints Glass to Metal Sealed Header Snap Action Electrical Element Neo-Dyn Industry Drive Valencia, CA tel: fax: AER0935_29 7/13 Specifications and dimensions subject to change.

129 Neo-Dyn Neo-Dyn Series 132TC Temperature Switch/Internal Compact, adjustable temperature switch featuring the efficient Nega-Rate Belleville disc spring for set point stability and vibration resistance. Available with all stainless steel exterior and interior construction together with a hermetically sealed, explosion-proof electrical assembly. Ideally suited for applications involving hazardous and corrosive medias or environments. Comes with capillary for remote mount up to 25 feet. Operating Temperature Data Adjustable Adjustable Set oint Range Deadband (approx) Bottom/Top roof Temperature Range B D F H J L N R Increasing F -50 to to to to to to to to to +655 Decreasing F -69 to to to to to to to to to +646 F 19/4 23/4 25/4 26/6 29/6 24/4 27/4 27/4 40/9 C 11 / 2 13 / 2 14 / 2 14 / 3 16 / 3 13 / 2 15 / 2 15 / 2 22 / 5 F * 750* C Deadband decreases as the adjustable set point is increased. For narrow deadband select set point in upper half of adjustable range. *Thermowell required for temperatures above 500 F. Standard Specifications Electrical Snap action electrical switch assemblies, art Numbers & (Form C) and & (Form CC), are listed by Underwriters Laboratories, Inc., FM Approval, CSA International and NCC (INMETRO). See the miscellaneous option N for additional listings. Electrical Connection 1/2 NT male conduit connection with VC insulated 18 AWG, 18" long leads rocess Connection 1/2 NT Male Remote mount Stainless steel 6' capillary with armor jacket, 10" minimum bendable tubing and 1/2" adjustable gland nut. Optional capillary lengths available. System ressure 1500 psig maximum roof ressure 2250 psig Internal, slotted adjustment nut with range scale Temperature Range Ambient: - 40 F to +180 F (-40 C to +82 C) See Electrical Assembly specification sheet for Temperature Class Ratings. Shipping Weight Approximately 3.5 pounds Ordering Sequence Select desired option for each category OTIONS stainless steel, graphite filled non-asbestos packing B -69 F dec. to +30 F inc. (-56 C dec. to -1 C inc.) D +7 F dec. to +125 F inc. (-14 C dec. to 52 C inc.) F +70 F dec. to +200 F inc. (21 C dec. to 93 C inc.) H +89 F dec. to +230 F inc. (23 C dec. to 110 C inc.) J +146 F dec. to +300 F inc. (63 C dec. to 149 C inc.) L +236 F dec. to +360 F inc. (113 C dec. to 182 C inc.) N +263 F dec. to +395 F inc. (128 C dec. to 202 C inc.) +338 F dec. to +480 F inc. (170 C dec. to 249 C inc.) R +445 F dec. to +655 F inc. (229 C dec. to 346 C inc.) C 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; CC 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; 6 Includes an explosion proof, hermetically-sealed electrical assembly. EX d IIC. Division 1 and 2, Class I, Groups A, B, C, and D; Class II, Groups E, F, and G. NEMA 4X, 7, and 9; I66. Leads are factory sealed and ressure Switches are Dual Seal Certified. A Epoxy paint exterior extra protection for severe environments D SIL approval and marking, per IEC61508 (includes FMEA report) H 316 stainless steel body I 3/4 NT conduit box with terminal strip (Groups C & D only, not available with N option) J Annealed stainless steel port screws for H 2 S environments M Gold electrical contacts for extremely low current applications N ATEX and IECEx with CE Mark R 72" Electrical free leads Optional Capillary Lengths 10', 15', 20' and 25' lengths available (insert appropriate number at end of model number see Example) Special (Consult representative or factory) Thermowells Non-catalog adjustable range and/or set point and deadband Order Option D Explosion roof Hermetically Sealed (NEMA 4X, 7, 9 and 13) Ordering rocedure When factory presetting is desired, stipulate set point, increasing or decreasing Insert available option number or letter designation as required Example 132TC 5BCC6 Series Optional Capillary Length

130 Field Adjustable -69 F to +655 F Series 132TC Envelope Dimensions 1.50 SQ Adjustable Gland Nut Nut Z\x 1/2 NT Flexible 300 Series Stainless Steel Armor Bendable Stainless Steel Extension Cover.380 Free Leads 18 AWG 18" Long Dia. Mtg. Holes (2 plac es) Conduit Connection Z\xNT 1/2 FORM "C" (SDT) T BLK YEL NC2 C2 FORM "CC" (DDT) T VIO NO2 Basic rinciples of Design Negative Rate Belleville Disc Spr ing Motion Transfer Arm All Stainless Steel Construction Electrical Assembly Actuator Minimum Bearing oints Glass o t Metal Sealed Header Snap Action Electrical Element Neo-Dyn Industry Drive Valencia, CA tel: fax: AER0935_28 7/13 Specifications and dimensions subject to change.

131 GENERAL UROSE NEMA 4, 4X & 13 déåéê~ä=mìêéçëé=té~íüéê=mêççñ= NNTm=pÉêáÉë Sanitary Food Service ^Çàìëí~ÄäÉ 21 SANITARY RESSURE SWITCHES HAZARDOUS AREA NEMA 7 & 9 eéêãéíáå~ääó=pé~äéçl=bñéäçëáçå=mêççñ= ^Çàìëí~ÄäÉ NNTm=pÉêáÉë harmaceutical/biochem 21

132 Neo-Dyn Neo-Dyn Series 117 Sanitary ressure Switch/Internal This field adjustable, compact pressure switch is intended for low- to mid-range process applications. The Tri-Clamp compatible, polished, process connection makes this switch ideal for food, beverage and other sanitary services. Set point stability and vibration resistance are a function of the Nega-Rate Belleville disc spring. This unit features 316 stainless steel construction, an explosion-proof/hermetically sealed electrical assembly, 18" standard free leads and SDT or DDT electrical forms and a wetted material surface polish of 9-11 micro inch Ra ( micron Ra). Operating ressure Data Adjustable Range Number Standard Specifications Electrical Snap action electrical switch assemblies, art Numbers & (Form C) and & (Form CC), are listed by Underwriters Laboratories, Inc., FM Approvals, CSA International and NCC (INMETRO). See the miscellaneous option N for additional listings. Electrical Connection 1/2 NT male conduit connection with VC insulated 18 AWG, 18" long leads ressure Connection 1 1/2" sanitary fitting mates with Tri-Clamp fitting Temperature Range Ambient: - 40 F to +180 F (-40 C to +82 C) Media: - 40 F to +250 F (-40 C to +121 C) Internal, slotted adjustment with range scale Shipping Weight Approximately 2 pounds Adjustable Set oint Range Increasing 3 to to to to to 725 Decreasing 1 to to to to to 680 All values given in psig. *Note: ressures are switch ratings. Check clamp manufacturer for clamp rating. Deadband (approximate) Ordering Sequence Select desired option for each category OTIONS stainless steel port and diaphragm, heliarc welded 2 1 psig dec. to 30 psig inc. (.07 bar dec. to 2.1 bar inc.) 4 15 psig dec. to 80 psig inc. (1.0 bar dec. to 5.5 bar inc.) 5 30 psig dec. to 250 psig inc. (2.1 bar dec. to 17.2 bar inc.) psig dec. to 400 psig inc. (12.1 bar dec. to 27.6 bar inc.) psig dec. to 725 psig inc. (22.8 bar dec. to 50.0 bar inc.) C 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; CC 11 amp, 1/4 hp at 125 or 250 VAC; 5 amp resistive, 3 amp inductive at 28 VDC; 6 Includes an explosion proof, hermetically-sealed electrical assembly. EX d IIC. Division 1 and 2, Class I, Groups A, B, C, and D; Class II, Groups E, F, and G. NEMA 4X, 7, and 9; I66. Leads are factory sealed and ressure Switches are Dual Seal Certified. I 3/4 NT conduit box with terminal strip (Groups C & D only, not available with N option) M Gold electrical contacts for extremely low current applications N ATEX approval R 72" Electrical free leads Special (Consult representative or factory) Non-catalog adjustable range and/or set point, deadband and proof pressure Tri-Clamp is a Registered Trademark of Tri-Clover Inc. *Maximum Recommended System ressure *roof ressure Ordering rocedure Example Explosion roof Hermetically Sealed (NEMA 4X, 7, 9 and 13) When factory presetting is desired, stipulate set point, increasing or decreasing Insert available option number or letter designation as required C 6 Series (specify)

133 Field Adjustable 1 to 725 psig Series 117 Envelope Dimensions Square Welded & olished Flush Mount Stainless Steel Sensing Diaphragm; 1¹ ₂ Sanitary Fitting; Mates with Tri-Clamp Fitting Access Cover Nameplate Location Free Leads, 18 AWG 18.0 Min. Length Electrical Connection ¹ ₂ - 14 NT FORM "C" (SDT) FORM "CC" (DDT) BLK NC2 YEL C2 VIO NO2 Basic rinciples of Design Snap Action Electrical Element Actuator Minimum Bearing oints Glass to Metal Sealed Header Sanitary Fitting Welded & olished Diaphragm ressure late All Stainless Steel Construction Electrical Assembly Motion Transfer Arm Negative Rate Belleville Disc Spring Neo-Dyn Industry Drive Valencia, CA tel: fax: AER0935_16 6/12 Specifications and dimensions subject to change.

134 Neo-Dyn Switch Accessories Thermowells /N ITT Neo-Dyn offers a line of standard thermowells for use on its direct mounted (100T/132T) or remote mounted (100TC/132TC) temperature switches. Available in 316 stainless steel with 3/4 or 1 inch process connections and insertion lengths up to 12 inches. Specifications DASH NO. FIGURE MATERIAL Q HEX SIZE U A -02 A 316 CRES 3/4 3/4 1-1/8 2-1/ A 316 CRES 1 7/8 1-3/8 2-1/ A 316 CRES 3/4 3/4 1-1/8 4-1/ A 316 CRES 1 7/8 1-3/8 4-1/ B 316 CRES 3/4 3/4 1-1/8 3-1/ B 316 CRES 1 3/4 1-3/8 3-1/ B 316 CRES 3/4 3/4 1-1/8 4-1/ B 316 CRES 1 3/4 1-1/8 4-1/ B 316 CRES 3/4 3/4 1-1/8 7-1/ B 316 CRES 3/4 3/4 1-1/8 10-1/ B 316 CRES 3/4 3/4 1-1/ /2 Envelope Dimensions FIG. A For use on 100T/132T Direct Mount FIG. B For use on 100TC/132TC Remote Mount Ordering rocedure Example Select a figure from the above. Figure A has a.260 bore diameter for use on 100T/132T models while Figure B has a.385 bore diameter for use on 100TC/132TC models. Select a process connection size: 3/4 or 1 inch. Select an insertion length: U. Standard 100T/132T models use 2-1/2 inch U dimensions; standard 100TC/132TC models use 3-1/2 inch U dimensions. art Number Dash Number Insert selected dash number at end of part number. See example ** Neo-Dyn Industry Drive Valencia, CA tel: fax: AER0935_54 11/14 Specifications and dimensions subject to change.

135 Neo-Dyn Switch Accessories Junction Box /N Explosion roof Junction Box with terminal strip electrical connections. Suitable for Div 1 hazardous areas when used in conjunction with any 6 electrical used on Neo-Dyn ressure or Temperature Switches. Div. 1 Explosion roof Standard Specifications Electrical Connection 3/4 NT female conduit connection. Area Classification Suitable for use in Div 1, Class I, Groups C & D; Class II, Group E, F & G hazardous locations in accordance with NFA 70. Wiring Guide Terminal strips will accept 14 to 20 AWG wire when installed in accordance with NFA 70. Ordering Sequence OTIONS -01 SDT Terminal Strip with markings to indicate normally open (NO), common (C) and normally closed (NC). -02 DDT Terminal Strip with markings to indicate two normally open (, NO2), two common (, C2) and two normally closed (, NC2) terminals. Examples Basic art Number DDT Terminal Strip

136 Junction Box /N Envelope Dimensions Basic rinciples of Design 3.0 3/4-14 NT Wiring Diagram Terminal Strip Grounding Screw 4.0 Ø 3.0 Explosion roof Coupling ainted Aluminum Housing Cover & O-Ring Not Shown Wiring Diagram Form 1 Form 2 Neo-Dyn Industry Drive Valencia, CA tel: fax: AER0935_53 11/14 Specifications and dimensions subject to change.

137 Neo-Dyn Switch Accessories Junction Box /N Weather roof Junction Box with terminal strip electrical connections. Suitable for Div 2 hazardous areas when used in conjunction with any 6 electrical used on Neo-Dyn ressure or Temperature Switches. Standard Specifications NEMA 4X or Div. 2 Hazardous Electrical Connection 1/2-14 NT female conduit connection Area Classification NEMA 4X weather proof enclosure suitable for Div 2, Class I, Groups C & D hazardous locations when used in conjunction with any enclosure 6 electrical and installed in accordance with NFA 70 Wiring Guide Terminal strips will accept 14 to 20 AWG wire when installed in accordance with NFA 70. Ordering Sequence OTIONS Junction Box L - Left Hand Connection S - Top Connection R - Right Hand Connection 1 SDT Terminal Strip with markings to indicate normally open (NO), common (C) and normally closed (NC) 2 DDT Terminal Strip with markings to indicate two normally open (, NO2), two common (, C2) and two normally closed (, NC2) terminals Examples L 2 Basic art Number Junction Box Form

Quick Reference Charts

Quick Reference Charts Quick Reference Charts Adjustable Pressure Switches 0" to 40" H 2 O 7" H 2 O to 15 psig.5 to 1900 psig 35 to 2300 psig 2.3 to 2800 psig 14 to 10000 psig ALUM. STAIN. MONEL BUNA N STAIN. TANTLM. Compact

More information

INSTALLATION AND OPERATION MANUAL

INSTALLATION AND OPERATION MANUAL NEO-DYN MODELS 100P, 101P, 110P, 180P, 200P, 201P ADJUSTABLE PRESSURE SWITCHES; MODEL 160P ADJUSTABLE DIFFERENTIAL PRESSURE SWITCHES, ENCLOSURE 3X FOR WEATHERPROOF APPLICATIONS INSTALLATION AND OPERATION

More information

NEO-DYN MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES; ENCLOSURE 3X FOR WEATHERPROOF APPLICATIONS INSTALLATION AND OPERATION MANUAL

NEO-DYN MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES; ENCLOSURE 3X FOR WEATHERPROOF APPLICATIONS INSTALLATION AND OPERATION MANUAL NEO-DYN MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES; ENCLOSURE 3X FOR WEATHERPROOF APPLICATIONS INSTALLATION AND OPERATION MANUAL PN 610-0012 Rev B Manual No. 610-0012 REV B Neo-Dyn 28150 Industry

More information

MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES,

MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES, NEO-DYN MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES, ENCLOSURE 6N FOR EXPLOSIVE ATMOSPHERES INSTALLATION AND OPERATION MANUAL PN 610-0014 E Manual No. 610-0014 Rev E Neo-Dyn 28150 Industry Drive

More information

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH INSTALLATION AND OPERATION MANUAL PN 610-0006 Rev E WARNING CAUTION SPECIAL CONDITIONS FOR SAFE USE NOTE Manual No. 610-0006 Rev

More information

TEMPERATURE AND PRESSURE SWITCHES

TEMPERATURE AND PRESSURE SWITCHES TEMPERATURE AND PRESSURE SWITCHES APPLICATIONS : HYDRAULIC, PNEUMATIC AND ENGINE LM Instrumentation 2 rue Junon 44 470 CARQUEFOU - FRANCE Tél. : +33 2 40 18 51 00 Fax : +33 2 40 18 51 10 lmi@lminstrumentation.fr

More information

Switches for Pressure to 8000 psig, Vacuum, Differential, or Level Control with General Purpose, Watertight or Explosion-Proof Enclosures

Switches for Pressure to 8000 psig, Vacuum, Differential, or Level Control with General Purpose, Watertight or Explosion-Proof Enclosures S-SERIES Pressure Switches Switches for Pressure to 8000 psig, Vacuum, Differential, or Level Control with, or s Features: Set point repeatability, +1% of operating range. All wiring terminals, adjustments

More information

Bourdon Tube Pressure Switches

Bourdon Tube Pressure Switches DA /DS Bourdon Tube es Visible setpoint, adjustable deadband, snap action switch pressure ranges to 000 psi Weather-Proof Types DAW, DSW, DRW -/1 2-1/1 REAR MOUNTING FLANGE ().20 DIA. HOLES AT 120 ON -1/2

More information

E. Clark & Associates 10 Brent Drive Hudson, MA Tel. 978 / Fax 978 / Two Switch Output Hex Screw Adjustment

E. Clark & Associates 10 Brent Drive Hudson, MA Tel. 978 / Fax 978 / Two Switch Output Hex Screw Adjustment CLARK SOLUTIONS 400 Series, Pressure, Vacuum, Diff. Pressure & Temp. Switches 1,2 & 3 Switch output, Adjustable Ranges 30 Vac to 6000 PSI, -180 to 650 o F DESCRIPTION The 400 Series is a versatile family

More information

Engineering Information. Solenoid Valves Principles of Operation. Solenoid Valves. Direct Acting Valves (Figures 1A, 1B)

Engineering Information. Solenoid Valves Principles of Operation. Solenoid Valves. Direct Acting Valves (Figures 1A, 1B) 4 Engineering Information Principles of Operation A solenoid valve is a combination of two basic functional units: A solenoid (electromagnet) with its core A valve body containing one or more orifices

More information

Adjustable Dead Band Pressure Switches

Adjustable Dead Band Pressure Switches Form 281 The adjustable dead band pressure switch should be used when there is a requirement for an adjustable and wide dead band between the increasing and decreasing set points. Function Alarm: Hi Lo

More information

^ % P-SERIES Temperature Switches. Switches for -30 through 510 F with Adjustable Set Points and Fixed or Adjustable Deadband

^ % P-SERIES Temperature Switches. Switches for -30 through 510 F with Adjustable Set Points and Fixed or Adjustable Deadband P-SERIES Temperature Switches Switches for -30 through 5 F with Adjustable Set Points and Fixed or Adjustable Features: Set point repeatability, + F (/2 C). All wiring terminals, adjustments and visual

More information

UNITED ELECTRIC 100 Series, Pressure, Vacuum, Diff. Pressure & Temp. Switches Adjustable Ranges 30 Vac to 5000 PSI, -180 to 650 o F

UNITED ELECTRIC 100 Series, Pressure, Vacuum, Diff. Pressure & Temp. Switches Adjustable Ranges 30 Vac to 5000 PSI, -180 to 650 o F UNITED ELECTRIC 100 Series, Pressure, Vacuum, Diff. Pressure & Temp. Switches Adjustable Ranges 30 Vac to 5000 PSI, -180 to 650 o F DESCRIPTION The 100 Series is a cost-effective pressure and temperature

More information

Adjustable Dead Band Pressure Switches

Adjustable Dead Band Pressure Switches The adjustable dead band pressure switch should be used when there is a requirement for an adjustable and wide dead band between the increasing and decreasing set points. Function Alarm: Hi Lo Control:

More information

Pressure Instrument Testing Equipment

Pressure Instrument Testing Equipment Pressure Instrument Testing Equipment BULLETIN TE-1 A Halliburton Company A Durable, Portable Primary Standard Model 1305D Deadweight Tester The Ashcroft 1305D Deadweight Tester is an affordable, portable

More information

U.S. GAUGE PMT PRODUCTS 820 PENNSYLVANIA BLVD., FEASTERVILLE, PENNSYLVANIA U.S.A. TEL: (215) FAX: (215)

U.S. GAUGE PMT PRODUCTS 820 PENNSYLVANIA BLVD., FEASTERVILLE, PENNSYLVANIA U.S.A. TEL: (215) FAX: (215) U.S. GAUGE PMT PRODUCTS 820 PENNSYLVANIA BLVD., FEASTERVILLE, PENNSYLVANIA 19053 U.S.A. TEL: (215) 355-6900 FAX: (215) 354-1801 www.ametekusg.com 2009, by AMETEK, Inc. All rights reserved. Printed in the

More information

PISTON STYLE GAUGE. Mid-West Instrument

PISTON STYLE GAUGE. Mid-West Instrument PISTON STYLE GAUGE Mid-West Instrument 1 BULLETIN NO. 120/11 (SUPERSEDES BULLETIN NO. 120/02) Mid-West Instrument Piston Type Differential Pressure Gauges Switches & Transmitters Model 120 A low cost differential

More information

Data Sheet. A-Series Miniature Watertight Pressure Switches. Factory set or field adjustable

Data Sheet. A-Series Miniature Watertight Pressure Switches. Factory set or field adjustable FEATURES Compact size 36 stainless steel construction Pressure ranges from vacuum to 5,000 psi Factory set or field adjustable setpoints Wide operating temperature range ( 40 C to 00 C) Precision snap-acting

More information

9012G Pressure and 9016G Vacuum Switches

9012G Pressure and 9016G Vacuum Switches Selection Guide 90G and 906G Vacuum Switches Type of installation Control circuits Power circuits Applications Media controlled Type of operation Air, water, hydraulic oils, () gases, steam Fixed differential:

More information

Dual Hi-Lo Pressure Switches

Dual Hi-Lo Pressure Switches Form 217 Dual Hi-Lo pressure switches are rugged field mounted instruments. The pressure sensing assemblies are conventional Static O Ring type. The main difference is that two sensing assemblies share

More information

Dual Hi-Lo Pressure Switches

Dual Hi-Lo Pressure Switches Dual Hi-Lo pressure switches are rugged, field-mounted instruments. The pressure sensing assemblies are conventional Static O Ring type. The main difference is that two sensing assemblies share a common

More information

PISTON STYLE GAUGE. For Installation and Operation Manuals Please Visit: Mid-West Instrument

PISTON STYLE GAUGE. For Installation and Operation Manuals Please Visit:   Mid-West Instrument PISTON STYLE GAUGE For Installation and Operation Manuals Please Visit: www.midwestinstrument.com/literature Mid-West Instrument BULLETIN NO. 120/11 (SUPERSEDES BULLETIN NO. 120/02) Mid-West Instrument

More information

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter BULLETIN NO. 220/11 (SUPERSEDES BULLETIN NO. 220/06) Mid-West Instrument Piston Type Model 220 Hazardous Locations Indicating / Non-Indicating Differential Pressure Switch or Transmitter Low cost piston

More information

Data Sheet. A-Series Miniature Watertight Pressure Switches

Data Sheet. A-Series Miniature Watertight Pressure Switches A-Series Miniature Watertight Pressure Switches FEATURES Compact size 36 Stainless steel construction Pressure ranges from vacuum to 000 bar (5.000 psi) Factory set or field adjustable setpoints Wide operating

More information

Type E-10, E-11 Hazardous Area Explosion-proof Transmitters

Type E-10, E-11 Hazardous Area Explosion-proof Transmitters Electronic Pressure Catalog > Hazardous Area > E-10, E-11 Type E-10, E-11 Hazardous Area Explosion-proof Transmitters Meets ANSI / ISA 12.27.01-2003 single seal requirements - no dual seal required Applications

More information

Section 3 - Chemical/Environmental Resistance Part 1 - XR-5 Fluid Resistance Guidelines

Section 3 - Chemical/Environmental Resistance Part 1 - XR-5 Fluid Resistance Guidelines Section 3 - Chemical/Environmental Resistance Part 1 - XR-5 Fluid Resistance Guidelines The data below is the result of laboratory tests and is intended to serve only as a guide. No performance warranty

More information

Features. North & South America: Europe / Africa / Middle East: Asia Pacific:

Features. North & South America: Europe / Africa / Middle East: Asia Pacific: PIG-SIG V Scraper Passage Indicator Optional mounting system available Bulletin No: 5110.003.09 Version: 11.2015 Supersedes: 5110.003.08 (03.2015) ECN: E006726 Options Available options: Flag Indicator

More information

Model 5000 Level Controller

Model 5000 Level Controller Features Multiple Configurations The 5000 level controller is easily configured for either reverse or direct actions for both pneumatic and electric pilot options. The pneumatic pilot is available in snap

More information

Scraper Passage Indicator Bulletin No: Version: Supersedes: ( ) ECN: E Features

Scraper Passage Indicator Bulletin No: Version: Supersedes: ( ) ECN: E Features PIG-SIG V Scraper Passage Indicator Bulletin No: 5110.003.08 Version: 03.2015 Supersedes: 5110.003.07 (02.2014) ECN: E003643 Options PIG-SIG V Scraper Passage Indicator mounted with THREAD-O-RING TM nipple

More information

short form catalog SFC 07

short form catalog SFC 07 short form catalog Electronic and Electromechanical Switches for Pressure, Differential Pressure, and Temperature Pressure Transmitters and Transducers Industrial Temperature Sensors SFC 07 is a privately

More information

Pressure Controls Product Overview

Pressure Controls Product Overview Bulletin Product Overview NEMA Bulletin Style A (Internal Bellows) Description Style C (External Bellows) Air Compressors Compressed Air Monitor Systems Liquid Level Control Typical Applications Vacuum

More information

Mid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

Mid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter BULLETIN NO. 240/11 (SUPERSEDES BULLETIN NO. 240/06) Mid-West Instrument Diaphragm Type Model 240 Hazardous Locations Indicating / Non-Indicating Differential Pressure Switch or Transmitter Field wireable

More information

Limit Switches. Reference Information. Proper Application of Limit Switches General Information. Definition of Limit Switch Terms.

Limit Switches. Reference Information. Proper Application of Limit Switches General Information. Definition of Limit Switch Terms. Reference Proper Application of General switches are used to convert a mechanical motion into an electrical control signal. The mechanical motion is usually in the form of a cam, a machine component or

More information

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 120

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 120 BULLETIN NO. 120/11 (SUPERSEDES BULLETIN NO. 120/02) Piston Type Differential Pressure Gauges Switches & Transmitters A low cost differential pressure gauge for use in measuring the pressure drop across

More information

Industrial Pressure Transmitters

Industrial Pressure Transmitters Industrial Pressure Transmitters Type S-10, S-11 Applications Hydraulics and pneumatics Test equipment Pump and compressor control Liquid level measurement Special Features Standard ranges available from

More information

Electropneumatic Timing Relays Series 7000 Industrial

Electropneumatic Timing Relays Series 7000 Industrial DESIGN FEATURES Available in On-Delay, True Off-Delay, and On/Off-Delay. Timing from 0.1 seconds to 60 minutes, fully calibrated in linear increments. Oversize time-calibrated adjustment knobs, serrated

More information

Dual Hi-Lo Pressure Switches

Dual Hi-Lo Pressure Switches see more at SORInc.com Request Quote Dual Hi-Lo Dual Hi-Lo pressure switches are rugged, field-mounted instruments. The pressure sensing assemblies are conventional Static O Ring type. The main difference

More information

DIAPHRAGM SEALS. MHP SERIES MINI HIGH PRESSURE Mini diaphragm seal for pressures up to 6000 psi

DIAPHRAGM SEALS. MHP SERIES MINI HIGH PRESSURE Mini diaphragm seal for pressures up to 6000 psi DIAPHRAGM SEALS seals, also referred to as isolators or chemical seals, are used to protect instruments from viscous, corrosive or very high temperature process media. PIC stocks, fills and calibrates

More information

S21 Series. - 1" NPT - Brass Body - 2-Way Piloted Diaphragm - Normally Open. Dimensions/Weight

S21 Series. - 1 NPT - Brass Body - 2-Way Piloted Diaphragm - Normally Open. Dimensions/Weight S21 Series - 1" NT - Brass Body - 2-Way iloted Diaphragm - s Seals: Nitrile, Viton, Ethylene ropylene Orifice: ilot Stainless Steel Main Brass Ø 1 Electrical Standard Housing: Encapsulated Waterproof Conduit

More information

M-100 Adjustable flow switch with right-angle flow

M-100 Adjustable flow switch with right-angle flow M-100 Adjustable flow switch with right-angle flow Operating Instructions and Quick Start Guide Table of Contents Introduction 03 Operation 03 Storage and Handling 03 Installation Instruction 03 Specification

More information

Metallic Systems TYPE SPTC

Metallic Systems TYPE SPTC CONDUIT 27/01/2009 Technical Data Sheet Page No. 1 Applications Hospitals External Safety Critical Area Fittings IP54 SPB Fittings type A & B Characteristics Very High UV Resistance High Flexibility Medium

More information

BULLETIN NO.ELEC IM121/10A Replaces IM121/09A

BULLETIN NO.ELEC IM121/10A Replaces IM121/09A Mid-West Instrument BULLETIN NO.ELEC IM121/10A Replaces IM121/09A INSPECTION Model 121 Indicating Differential Pressure Switch / Transmitter Electrical: Installation and Operating Instructions Upon receipt

More information

Mid-West Instrument. Diaphragm Type Differential Pressure Gauge & Switch Model 130. Shown here with Range 0-5 H2O

Mid-West Instrument. Diaphragm Type Differential Pressure Gauge & Switch Model 130. Shown here with Range 0-5 H2O Diaphragm Type Differential Pressure Gauge & Switch BULLETIN NO. 130/11 (SUPERSEDES BULLETIN NO. 130/02) is a rugged general purpose differential pressure gauge with a 4-1/2" round dial. Common Applications:

More information

EZ-View. Flow Meters ISO CERTIFIED 9001

EZ-View. Flow Meters ISO CERTIFIED 9001 EZ-View ISO CERTIFIED 9001 General Design Features OPERATING PRINCIPLE The EZ-View Flow Meter is a variable-area instrument. A precisionmolded, sharp-edged Orifice, located within the Piston Assembly,

More information

Ultra High Purity Transducer, Ex na nl Models WU-20, WU-25 and WU-26

Ultra High Purity Transducer, Ex na nl Models WU-20, WU-25 and WU-26 Electronic Pressure Measurement Ultra High Purity Transducer, Ex na nl Models WU-20, WU-25 and WU-26 WIKA Datasheet WU-2X Applications Gas panels for OEM tools Semiconductor, flat panel display and photovoltaic

More information

SOLON PRESSURE SWITCHES

SOLON PRESSURE SWITCHES SOLON SWITCHES Performance Under Pressure A Full Line of Electromechanical and Pneumatic Valve Actuated Pressure Switches & Temperature Controlled Density Switches 2 Solon Manufacturing www.solonmfg.com

More information

S21 Series. - 2" NPT - Brass Body - 2-Way Piloted Diaphragm - Normally Open. Dimensions/Weight

S21 Series. - 2 NPT - Brass Body - 2-Way Piloted Diaphragm - Normally Open. Dimensions/Weight S21 Series - 2" NT - Brass Body - 2-Way iloted Diaphragm - s Seals: Nitrile, Viton, Ethylene ropylene Orifice: ilot Stainless Steel Main Brass Ø 1 1/4 Electrical Standard Housing: Encapsulated Waterproof

More information

NEMA 4 High Pressure High Set Point High Accuracy Pressure Switch SPECIFICATIONS

NEMA 4 High Pressure High Set Point High Accuracy Pressure Switch SPECIFICATIONS Pressure Switches P605L NEMA 4 High Pressure High Set Point High Accuracy Pressure Switch OVERVIEW The Whitman Controls P605L NEMA 4 High Pressure High Set Point High Accuracy Pressure Switches are a line

More information

CAPSU-PHOTOHELIC PRESSURE SWITCH/GAGE*

CAPSU-PHOTOHELIC PRESSURE SWITCH/GAGE* CAPSU-PHOTOHELIC PRESSURE SWITCH/GAGE* Specifications - Installation and Operating Instructions Bulletin B-34 Series 43000 CAPSU-Photohelic Switch/Gage The CAPSU-Photohelic Switch/Gage is a most versatile,

More information

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 124

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 124 BULLETIN NO. 124/12 (SUPERSEDES BULLETIN NO. 124/11) Mid-West Instrument Piston Type Differential Pressure Gauges Switches & Transmitters A low cost differential pressure gauge for use in measuring the

More information

Temperature Switches

Temperature Switches Temperature Switches Temperature Switches c Pressure - Electronic Pressure Switches - Mechanical Pressure Switches - Pressure Transducer c Valves & Regulators c Temperature c Level c Flow c Air Suspension

More information

Models 910, 911, 916, 917, 920, 921, 927 ASME Section VIII, Air/Gas/

Models 910, 911, 916, 917, 920, 921, 927 ASME Section VIII, Air/Gas/ Models 910, 911, 916, 917, 920, 921, 927 ASME Section VIII, Air/Gas/ Steam/Liquid, UV National Board Certified. Also available for Vacuum Service Model 921: Steel body and bonnet with plain lift lever

More information

Temperature Products. Temperature Products

Temperature Products. Temperature Products Temperature Products Temperature Products u Electronic Products u Pressure Transducers u Mechanical Pressure Products u Valves & Regulators u Temperature Products u Level Products u Air Suspension Valves

More information

ASCO Pressure and Temperature Switch SELECTION GUIDE and INDEX

ASCO Pressure and Temperature Switch SELECTION GUIDE and INDEX ACO ressure and Temperature witch ELECTION GUIDE and INDEX witches Type et oint Reset oint Enclosure Ranges ages REURE J-ERIE Miniature ressure witches with Non- et oints ressure Non- Fixed ealed 6.5-162

More information

10 S e r i e s PRESSURE SWITCH. features

10 S e r i e s PRESSURE SWITCH. features 10 S er i es 10 S e r i e s PRESSURE SWITCH features Tamper-Resistant Field Adjustment Adjustable Ranges from 4 to 7500 PSI (0,3 to 517,1 Bar) Choice of 7 Electrical Terminations 1-1/4" Diameter Height

More information

Type 2000 Transducer Product Instructions

Type 2000 Transducer Product Instructions Type 2000 Transducer Product Instructions The Type 2000 is an electro-pneumatic device that regulates an unregulated supply pressure down to an electronically-controlled output pressure. There are two

More information

PS11 Ultra-Long Life OEM Pressure Switches

PS11 Ultra-Long Life OEM Pressure Switches PS11 Ultra-Long Life OEM Pressure Switches 0.75 to 15 psi (52 to 1034 mbar) Factory Set or Adjustable Set Points For low pressure applications, the longevity of our PS11 Series is hard to beat. Their snap-action

More information

High Pressure Solenoid Valves

High Pressure Solenoid Valves High Pressure Solenoid Valves Available for Quick Delivery Controls the flow of Gases & Liquids up to 15,000 PSIG Natural Gas, Hydrogen & other High Pressure Gases High Pressure Cryogenics Flammable Liquids

More information

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 123

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 123 BULLETIN NO. 123/11 (SUPERSEDES BULLETIN NO. 123/03) Piston Type Differential Pressure Gauges Switches & Transmitters A low cost differential pressure gauge for use in measuring the pressure drop across

More information

Type Type 1001 Transducers. I/P & E/P Transducers

Type Type 1001 Transducers. I/P & E/P Transducers Type 1001 I/P & E/P Description The Type 1001 is a patented family of electropneumatic instruments that is used to reduce a supply pressure to a regulated output pressure which is directly proportional

More information

J 6 Se r i e s. Pressure and Vacuum switches. features

J 6 Se r i e s. Pressure and Vacuum switches. features J 6 S er i es J 6 Se r i e s Pressure and Vacuum switches features Gasketed, Die Cast Aluminum Enclosure with Epoxy Coating SPDT Switch Output Adjustable Deadband Option Sealed, Isolated Metal Bellows

More information

M3500 Industrial Pressure Transmitter

M3500 Industrial Pressure Transmitter M3500 Industrial Pressure Transmitter The M3500 is a high accuracy industrial pressure transmitter featuring HART communications and a cast aluminum enclosure for indoor or outdoor use. Typical output

More information

Pressure Controller. Cataloge K Code Characteristics Index. K00-2 Pressure Controller Brief Introduction

Pressure Controller. Cataloge K Code Characteristics Index. K00-2 Pressure Controller Brief Introduction K Pressure Controller Cataloge Code Characteristics Index K00-2 Pressure Controller Brief Introduction KC32 Screw Tube Differential Pressure Controller K01 KY10 Bellows Type Differential Pressure Controller

More information

S40 Series. - 1/4" NPT - Stainless Steel Body - 2-Way Piloted Piston - Normally Open. Dimensions/Weight

S40 Series. - 1/4 NPT - Stainless Steel Body - 2-Way Piloted Piston - Normally Open. Dimensions/Weight S40 Series - " NT - Stainless Steel Body - 2-Way iloted iston - Materials Seals: Nitrile, Viton, Teflon, Ethylene ropylene Orifice: ilot Stainless Steel Main Stainless Steel Ø 3/8 Electrical Standard Housing:

More information

Pressure switch FF 4 Approval acc. to ATEX EN For mining and chemistry

Pressure switch FF 4 Approval acc. to ATEX EN For mining and chemistry Approval acc. to ATEX EN 679 Description n... 3 bar with perbunan diaphragm. n 6... 5 bar with plastic plunger and throttle. n Throttle must be removed when using viscous media. 151 mm 7 13 mm a 1 mm,5

More information

CONNECTION BULLETIN. Vogt Valves. Experience In Motion. Zero Leakage Forged Steel Check Valves Class 800. FCD VVABR /04 (Replaces CB-03)

CONNECTION BULLETIN. Vogt Valves. Experience In Motion. Zero Leakage Forged Steel Check Valves Class 800. FCD VVABR /04 (Replaces CB-03) CONNECTION BULLETIN Vogt Valves Zero Leakage Forged Steel Check Valves Class 800 FCD VVABR1003-00 10/04 (Replaces CB-03) Experience In Motion Zero Leakage, Forged Steel Check Valves: Class 800 Vogt Series

More information

Dual Hi-Lo Pressure Switches

Dual Hi-Lo Pressure Switches Dual HiLo Form 217 Product Description Dual HiLo pressure switches are rugged field mounted instruments. The pressure sensing assemblies are conventional Static ORing type. The main difference is that

More information

OEM Pressure Transmitters

OEM Pressure Transmitters OEM Pressure Transmitters Type ECO-1 Applications Hydraulics and pneumatics Mechanical engineering General industrial applications Special Features Pressure ranges from 0-15psi to 0...15,000psi 4-20 ma

More information

PRESSURE, VAcuum, DIFFERENTIAL PRESSURE,

PRESSURE, VAcuum, DIFFERENTIAL PRESSURE, 12 S er i es 12 Se r i e s PRESSURE, VAcuum, DIFFERENTIAL PRESSURE, AND TEMPERATURE SWITCHES PRESSURE, DIFFERENTIAL PRESSURE, AND TEMPERATURE SWITCHES DUAL SEAL CERTIFIED Features Compact 316 Stainless

More information

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries Product Data Sheet January 214 813-1-475, Rev FA Rosemount 875WA Magnetic Flowmeter System For Water and Wastewater Industries THE 875WA MAGNETIC FLOWMETER Rosemount reliability in a customized offering

More information

check valves BIVCO Check Valves

check valves BIVCO Check Valves BIVCO valves are considered all-purpose valves because they can be tailored in the right combination of materials for the job at hand for liquids, including acids, alkalais, formaldehyde, solvents, oils,

More information

the Interactive Catalog

the Interactive Catalog Interactive Catalog Supplements Catalog PDFs If you need detailed product information, or help choosing the right product for your application, see our Interactive Catalog Use the Interactive Catalog to

More information

DWYER INSTRUMENTS, INC. Phone: 219/ P.O. BOX 373 MICHIGAN CITY, IN 46361, U.S.A. Fax: 219/

DWYER INSTRUMENTS, INC. Phone: 219/ P.O. BOX 373 MICHIGAN CITY, IN 46361, U.S.A. Fax: 219/ Series 43000 Capsu-Photohelic Pressure Switch/Gage Specifications - Installation and Operating Instructions Bulletin B-34 Ø4-3/4 [120.65] 3-7/8 SQ [98.43] 3/4 CONDUIT 4-3/8 [111.13] HOUSING REMOVAL 3-1/16

More information

Fisher 546 Electro Pneumatic Transducer

Fisher 546 Electro Pneumatic Transducer 546 Transducer Product Bulletin Fisher 546 Electro Pneumatic Transducer Fisher 546 transducers receive a direct current input signal and use a torque motor, nozzle flapper, and pneumatic relay to convert

More information

1100 Series Piston Type Differential Pressure Gauges

1100 Series Piston Type Differential Pressure Gauges 1100 Series Piston Type Differential Pressure Gauges 1. Safety Before installing, check the Series Number and verify compatibility to the process media and temperature in contact with the wetted parts.

More information

Valves. External Valves, Gages and Fittings. Bulletin No What options are available when stainless steel is not suitable for external parts.

Valves. External Valves, Gages and Fittings. Bulletin No What options are available when stainless steel is not suitable for external parts. External Valves, Gages and Fittings Bulletin No. 218 What options are available when stainless steel is not suitable for external parts. Unless otherwise specified, the external valves, gages, fittings

More information

Control pressure switch series FF 4

Control pressure switch series FF 4 .11 up to 5, ample wiring room, easy to adjust high repeatability of set switchpoints, easily read scale Applications Air compressors, water pumps, booster pumps, firefighting equipment, oil supply equipment.

More information

AST44LP Intrinsically Safe Low Pressure Transducers / Transmitters

AST44LP Intrinsically Safe Low Pressure Transducers / Transmitters AST44LP Intrinsically Safe Low Transducers / Transmitters Class I Division 1 Groups C, D IS with Approved Barrier OVERVIEW The AST44LP is a stainless steel pressure transducer with a wide variety of options.

More information

2000 Series Geared Rotary Limit Switches

2000 Series Geared Rotary Limit Switches SUPERIOR DESIGN AND OPERATING FEATURES Quality parts make each Geared Rotary Limit Switch highly dependable. The limit switch s ½ input shaft drives a bronze gear which rotates the cam block. The cam block

More information

2 1 /2" Glycerin-Filled Dual Scale Vacuum Gauges

2 1 /2 Glycerin-Filled Dual Scale Vacuum Gauges BAC-25 Brass Case Dial Size: 2 1 /2" Glycerin Filled Pressure Ranges: 30" HG to 15,000 PSI/Bar (Dual Scale) Accuracy: Within 1.5% of Maximum Graduation Case: Forged Brass With Polished Brass ABS Bourdon

More information

12 Volt DC Diaphragm Pumps Series 400

12 Volt DC Diaphragm Pumps Series 400 Page 1 of 6 12 Volt DC Diaphragm Pumps Series 400 More Information Index Description of Included Models Safety Listings Available Options Accessories Performance Flow Curve Fluid Compatibility Dimensions

More information

Operating Instructions. Valves Atkomatic Series ATEX and Series ATEX Series Series

Operating Instructions. Valves Atkomatic Series ATEX and Series ATEX Series Series Operating Instructions Valves Atkomatic 15800 Series ATEX and 30800 Series ATEX 15800 Series 30800 Series Atkomatic 15800 Series ATEX and 30800 Series ATEX Installation and Maintenance Instructions Revision

More information

Steam & Hot Water INSTRUMENTS. Adjustable Angle Industrial Thermometer. Econo Thermometer. ] Aluminum Stem. ] Air-Duct Stem

Steam & Hot Water INSTRUMENTS. Adjustable Angle Industrial Thermometer. Econo Thermometer. ] Aluminum Stem. ] Air-Duct Stem Adjustable Angle Industrial Thermometer Recognized globally as the Trerice BX Industrial Thermometer, this is an instrument of extreme accuracy and rugged dependability. Available in scale lengths of 7"(AX),

More information

AP/UP, AP/MIL Series Magnetic Circuit Protectors

AP/UP, AP/MIL Series Magnetic Circuit Protectors AP/UP, AP/MIL AP/UP, AP/MIL Series Magnetic Circuit Protectors Introduction 68 Single Pole 69 Multi-Pole 70 Configurations 72 Operating Characteristics 73 Delay Curves 74 Specifications 75 Decision Tables

More information

O.E.M GAUGES. For Installation and Operation Manuals Please Visit: Mid-West Instrument

O.E.M GAUGES. For Installation and Operation Manuals Please Visit:   Mid-West Instrument O.E.M GAUGES For Installation and Operation Manuals Please Visit: www.midwestinstrument.com/literature Mid-West Instrument Product Notes: BULLETIN NO. 126-127/11 (SUPERSEDES BULLETIN NO. 126-127/00) O.E.M

More information

SPANS AND RANGES. Lower Range Limits 150 in. H 2 O ( 38 kpa) 800 in. H 2 O ( 200 kpa)

SPANS AND RANGES. Lower Range Limits 150 in. H 2 O ( 38 kpa) 800 in. H 2 O ( 200 kpa) Specifications 571T, 572T Electronic Differential Pressure Transmitter with Sanitary/ Aseptic Remote Seal Elements ±0.2% of span accuracy Spans from 25 to 800 inches H2O Outstanding temperature stability

More information

From 2 to 6000 PSI (40 mbar to 400 bar), GEMS Pressure Switches Cover A Wide Range of Applications

From 2 to 6000 PSI (40 mbar to 400 bar), GEMS Pressure Switches Cover A Wide Range of Applications From 2 to 6000 PSI (40 mbar to 400 bar), GEMS Pressure Switches Cover A Wide Range of Applications General, Vacuum, Differential, Specialty Field-Adjustable or Factory Set Switches High Proof Pressure

More information

UNIVERSAL Flow Meters

UNIVERSAL Flow Meters MAX FLOW SIZES FROM 500 TO 1500 GPM (2000 TO 5600 LPM) MAX LIQUID PRESSURE 300 PSIG (20.69 BAR) XHF SERIES UNIVERSAL Flow Meters An Extra-Large Vane Style For Liquids NIST Traceable Calibration Certificate

More information

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 122

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 122 BULLETIN NO. 122/11 (SUPERSEDES BULLETIN NO. 122/01) Piston Type Differential Pressure Gauges Switches & Transmitters A low cost differential pressure gauge for use in measuring the pressure drop across

More information

Pressure switch FF up to 250 bar, ample wiring room, easy to adjust high repeatability of set switchpoints, easily read scale

Pressure switch FF up to 250 bar, ample wiring room, easy to adjust high repeatability of set switchpoints, easily read scale Microlectra bv. www.microlectra.nl info@microlectra.nl Pressure switch FF.11 up to 25, ample wiring room, easy to adjust high repeatability of set switchpoints, easily read scale 151 mm 75,5 mm a 1 mm,5

More information

MS4525 SPECIFICATIONS

MS4525 SPECIFICATIONS SPECIFICATIONS PCB Mounted Pressure Transducers Amplified Ratiometric Analog Output Differential, Gage, Absolute, Compound, & Vacuum Temperature Compensated 3.3 or 5.0 Vdc Supply Voltage The MS4525 is

More information

Swivel Joints Flexmaster Joints BD BD BD BD BD BD

Swivel Joints Flexmaster Joints BD BD BD BD BD BD FLUID CONVEYING PRODUCTS Section Pages Hose 15-67 Fittings 68-180 Adapters and Tube Fittings 181-228 Description Page How to Order 230 Selection Criteria 231 Selection Chart 232 Fluid Compatibility Chart

More information

Miniature Inert PTFE Isolation Valves. Physical Properties Electrical Performance Characteristics

Miniature Inert PTFE Isolation Valves. Physical Properties Electrical Performance Characteristics 2-Way and 3-Way Solenoid Valves Typical Applications Reagent Control Solvent Management Aggressive Liquid Control Product Specifications Valve Type: Diaphragm Isolation Valve Valve Configuration: 3-Way

More information

Diaphragm Seals TYPE12. Tri-Clamp Sanitary Pressure

Diaphragm Seals TYPE12. Tri-Clamp Sanitary Pressure Tri-Clamp Sanitary Diaphragm Seals TYPE12 Features a flush mount diaphragm and all welded construction, ideal for food & beverage, pharmaceutical and sanitary markets Wetted parts and all welded housing

More information

Specialty Gauge Catalog Index

Specialty Gauge Catalog Index Specialty Gauge Catalog Index Specialty Gauge Introduction 3 Process Gauges - Series NF4UGY and LF4UGY 4 4 Series NF4UGY5 & LF4UGY5 and Dimensions 5 Standard Ranges 6 Ultra Pressure Gauges - Series UG-1

More information

Model 5000 Level Controller

Model 5000 Level Controller Features Multiple Configurations The 5000 level controller is easily configured for either reverse or direct actions for both pneumatic and electric pilot options. The pneumatic pilot is available in snap

More information

PRESSURE BENCH OPERATING INSTRUCTIONS

PRESSURE BENCH OPERATING INSTRUCTIONS PRESSURE BENCH OPERATING INSTRUCTIONS Overview: The pressure bench system allows the user to apply a variety of calibrated pressures to a variety of high and low pressure transducers. In addition the system

More information

SATRON VDt Differential Pressure Transmitter

SATRON VDt Differential Pressure Transmitter SATRON VDt differential pressure transmitter belongs to V-transmitter family. The series V transmitters have both analog and smart properties. SATRON VDt is used for -,1kPa...-15 MPa ranges. It is a 2-wire

More information

Temperature Switches. General Instructions

Temperature Switches. General Instructions This instruction provides information for mounting, electrical connection, process connection, and calibration of SOR Temperature Switches. The SOR Inc. Temperature Switch consists of a pressure switch

More information

Process Industry. Diaphragm Seal Solutions

Process Industry. Diaphragm Seal Solutions Process Industry Diaphragm Seal R Overview Diaphragm Seal Systems Provide Protection to Ensure Safety, Reliability Diaphragm seal systems protect gauges from hot, viscous, contaminated or corrosive media.

More information