Temperature Switches

Size: px
Start display at page:

Download "Temperature Switches"

Transcription

1 Temperature Switches Temperature Switches c Pressure - Electronic Pressure Switches - Mechanical Pressure Switches - Pressure Transducer c Valves & Regulators c Temperature c Level c Flow c Air Suspension Valves

2 Table of Contents Temperature Switches Supplemental Guide 3 Temperature Switch Accessories 7 Series TXR, TXL - Explosion Proof Temperature Switch 9 Series TPR - General Purpose Switch Series THR, THL - Temperature Switch 3 T9692X - Compact Explosion Proof Temperature Switch 5 Series TX, T2X, LX - Explosion Proof Temperature Switches 7 Series MTH, T2H - Remote Mount Temperature Switches 9 Series MLS - Bi-Metallic Switch 2 MLH, L2H - Local Mount Temperature Switches 23

3 Temperature Supplemental Guide Sensor Types Temperature Switch Products Local Mount Local mount type temperature switches are installed in the pipe or vessel. ln this type of sensor, the filling fluid surrounds the bellows. A negative temperature change forces the fluid to contract-expanding the bellows to actuate the switch. Positive temperature changes produce the opposite effect. Remote Bulb & Capillary Remote temperature switches allow the switch enclosure to be placed up to 25 feet from the media. These models use a bulb and capillary sensing device which may be ordered in standard six and 2 foot lengths. Extra lengths up to 25 feet are available. Six and 2 foot sensors can be copper or stainless steel with or without protective spiral-wound armor. The 25 foot lengths are armored stainless steel only. SINGLE OR DUAL CONTROL WATERTIGHT (NEMA 4 & 3) EXPLOSION PROOF (NEMA 7 & 9) ENCLOSURES GROUNDING SCREW PROVIDED TERMINAL STRIP LABELED 'C', 'NO' & 'NC' (SPOT SWITCH ELEMENTS) WIRES ARE COLOR CODED SNAP ACTION SWITCH OPTIONAL ADJUSTABLE DIFFERENTIAL THREADED CONDUIT CONNECTION TAMPERPROOF ADJUSTMENT COVER SELF-LOCKING ADJUSTMENT FIELD ADJUSTABLE WITH CALIBRATED DIAL (CALIBRATED C & F SAME DIAL) HIDDEN MOUNTING SCREW (NO PROTRUDING LUGS) CASE BULB MOUNT IN ANY POSITION MOTION AND VIBRATION RESISTANT OVERTRAVEL PROTECTION AMBIENT COMPENSATION DEVICE CANCELS OUT ADVERSE EFFECTS OF AMBIENT FLUCTUATION STAINLESS STEEL OR COPPER CAPILLARY IN 6' OR 2' STANDARD OR CUSTOM LENGTHS TO SUIT SUBMERISIBLE IN PRESSURIZED VESSEL (PRESSURE RANGE THROUGH 300 PSI) WIDE RANGE OF MEDIA & TEMPERATURE LIMITS (REMOTE BULB, LIQUID FILL) STANDARD OR CUSTOM LENGTH ARMORED CAPILLARIES AVAILABLE Barksdale offers both remote and local mount temperature switches in housed, NEMA 4 and/or explosion proof designs. All are available with one or two adjustable temperature set points and fixed or adjustable differential.

4 Supplemental Guide Temperature Switch Products General Data Barksdale was the first manufacturer to offer effective ambient compensation in electromechanical switches revolutionizing temperature switch accuracy through extreme temperature changes. In a liquid-filled bulb and capillary system, ambient temperature changes affect the expansion of the fluid resulting in false temperature sensing. An extreme ambient change from -65 F to + 65 F will decrease the accuracy of most switches by 20% or more. Or, if the temperature changes only 70, accuracy can be decreased by 5%. ±% Accuracy From Barksdale Bulb and capillary configurations overcome ambient temperature swings through stacking of precision, concave bimetal washers. An ambient temperature change causes the liquid fill in the bulb, capillary and bellows to expand or contract, an equal and opposite reaction occurs between the washers. This compensates for ambient temperature change assuring high repeatable accuracy even under wide ambient temperature swings. By reacting to ambient temperature changes as extreme as - 65 F to + 65 F, the accuracy of the mid-60% of the adjustable range is still within ±% of full-scale. Accuracy at constant ambient is ±0.5% full scale. Local mount temperature switches are not affected by ambient temperature changes in the same way as bulb and capillary types. All of the filling fluid is exposed to the media temperature the bulb is sensing. Therefore, there is no ambient temperature influence on the filling fluid. Ambient Temperature Compensation Comparison Curve Good Response Time Select for Mid-Range Setting For optimum repeat accuracy in areas of extreme temperature change, select the switch range that enables the desired set point to fall in the mid 60% of the adjustable range. 2

5 Temperature Supplemental Guide General Data Temperature Switch Products Differential (Actuation Value, Dead Band, Hysteresis) BY CLASS OF ELECTRICAL SWITCH USED IN BARKSDALE TEMPERATURE SWITCHES Differential tolerances on temperature switches are due to manufacturing tolerances on limit switches and sensing elements. The differential of each temperature switch will remain fixed within the tolerances shown. Test conditions and media used could affect differential. Hermetically Sealed Switches Barksdale Hermetically Sealed Temperature Switches were created for use in hostile environments where exposure to elements such as salt air, hydrogen sulfide and other corrosive agents and atmospheres might cause contact deterioration and switch failure. The switch elements meet the requirements for Class I, Division II hazardous areas. The Barksdale hermetically sealed switch element is the same size as most nonsealed micro-switches, making this modification of our standard switches simple and inexpensive.. Select the standard unit with the desired characteristics. 2. Refer to the catalog sections showing the actuation value (differential) and electrical rating of switch elements by class. (The Class of Electrical Switch for Hermetically Sealed switch elements is either AA, CC or HH.) Select the class (AA, CC or HH) desired. 3. Change the standard catalog number as follows: - Prefix the catalog number with H. - Substitute AA or HH for the standard switch element designation. - Drop any -UL suffixes. Examples: - Standard Catalog number T2H-H5 - Hermetically Sealed numbers are HT2H-AA5, HT2H-CC5 or HT2H-HH5 Sensing Element Adjustable Approximate Differential (Actuation Value, Deadband, Hysteresis) Range - F by class of switch element Bulb & Capillary Type Sensor B GH, H J K L M S Adjustable G** Can be AA HH CC to from reset after MTH to T2H to TX to T2X to Local Mount MLH -20 thru thru L2H -45 thru thru LX -45 thru thru *Differential values are the same for copper and stainless steel **-RD Models ***T2H, T2X, L2H Models Electrical Rating (Current given in Amperes) () For standard models the electrical ratings are listed on each page under lectrical Characteristics? (2) For other switch ratings, see table below and refer to corresponding Operating Characteristics. - Class GH switches are SPOT with gold contacts. - Class J & K switches are SPDT with fine silver contacts and an Elastomer Boot around pin actuators to prevent moisture and foreign matter from affecting contacts. - Class G switches are manual reset. - Class R & S switches are SPOT with fine silver contacts and adjustable differentials. - All other switch classes are SPOT with fine silver contacts and fixed differentials. - Class H & M switches meet humidity requirements of MIL-S Class AA, CC & HH hermetically sealed. AC RATINGS INDUCTIVE LOAD - 50% POWER FACTOR CLASS OF MAXIMUM CONTINUOUS CURRENT SWITCH H,J B,K L M S G GH AA HH CC VOLTS AC DC RATINGS INDUCTIVE LOAD - L/R =.26 CLASS OF MAXIMUM CONTINUOUS CURRENT SWITCH H B,K L M S G GH VOLTS DC

6 Supplemental Guide Temperature Switch Products General Data Temperature Conversion Table Find in the center column the number of the known temperature. If the known temperature is in Fahrenheit, the Centigrade equivalent is in the left hand column. If in Centigrade, the Fahrenheit equivalent is in the right hand column. The basic conversion formulas are: C = F - 32 X 5/9, OR C = F - 32 F = C X 9/5 + 32, OR F = C X C F/ C F C F/ C F C F/ C F C F/ C F Temperature Switch Operation and Safety WARNING Product must be installed in accordance with applicable NEC, ASME and local regulations as applicable including those that apply to installations in hazardous locations requiring explosion proof enclosures or similar construction. The temperature limitations shown on the individual catalog pages for the specific switch must not be exceeded. These temperatures must take into consideration the possible maximum system temperatures encountered. The maximum allowable pressure on the sensor is 300 psi. Over 300 psi, use suitable thermowell. The fluid used must be compatible with the materials of construction. Special cleaning and packaging may be required for special media such as oxygen. Consult factory. Temperature switches are not of sanitary construction and the fill fluid is toxic. Therefore, sensors should not be in contact with materials intended for ingestion unless suitable thermowell is used. Sensors listed in this catalog are filled with silicon oil. When silicon oil is combined with strong oxidizing agents, including (but not limited to) chlorine, nitric acid, and hydrogen peroxide, a spontaneous chemical reaction, ignition or explosion can result. When temperature switches containing fluid are used in such service, thermowells must be used. The electrical load through the temperature switch must not exceed the values shown in the catalog for the specific switch involved. Shock and vibration may affect the switch performance. Therefore, shock and vibration should be minimized. Consult factory for assistance. Troubleshooting and Maintenance Troubleshooting of the switch must be in strict compliance with the procedure set forth on the Troubleshooting and Maintenance section of this catalog. Field repair of UL, CSA or other listed units will void the UL or CSA listing of the repaired unit. Barksdale, Inc. components must not be used in life support applications of any kind. Failure to observe these warnings could result in serious injury or damage. 32 Fruitland Avenue Los Angeles, CA Fax: See Barksdale s Standard Conditions of Sale Specifications are subject to modification at any time Bulletin #T0027-B 09/ Printed in the U.S.A.

7 Temperature Temperature Switch Accessories Thermowells, Split Nut, Union Connector, Capillaries Standard Local Mount Standard Local Mount /2 NPT threads Sensor submersible in pressurized vessel; pressure range through 300 psi. Example: MLH-H20S Sensor 3/4 NPT threads Thermowell Option: -W: Brass -WS: 36 Stainless Steel #0 Set screws (2); secures switch in thermowell; can be rotated 360 in well. Sensor submersible in pressurized vessel; pressure range: 000 to 7000 psi, depending on material and temperature. NOTE: Barksdale standard models cannot be field converted to add a Barksdale thermowell. To order a standard temperature switch with thermowell, add -WS to the model number. Example: MLH-H20S-WS Example: MLH-H20S-WS To order replacement temperature switch for thermowell models, less thermowell, add -Z8 to model number. Example: MLH-H20S-WS-Z8 Thermowells for High Pressure and Harsh Environments Thermowells for Remote Bulb and Capillary Models Only All electromechanical temperature switches may be used with a thermowell when pressures exceed 300 psi, if high velocities are present and with corrosive or abrasive medias. Thermowells also allow removal of the temperature switch or sensor without loss of contained media. When using a thermowell with a local mount temperature switch, two set screws are provided to secure the switch in the well allowing 360 rotation for easier electrical connection and readability. The use of a thermowell may increase response time to temperature change. By using heat transfer material, the increase can be kept to a minimum. Part Number Material P Process Connection NPT R V B Brass / B Brass 3/ C 36SS / C 36SS 3/

8 Temperature Switch Accessories Thermowells, Split Nut, Union Connector, Capillaries Split Nut Used to hold sensor bulb in standard thermowell. Union Connector Used to hold sensor bulb in extra length thermowell. Seals the process connection where no thermowell is used. Note: Union contains compression discs and will seal to 300 psi. /2" NPT Part P Number Material NPT A 4086-B Brass /2 2-/ B Brass 3/4 2-/ C 36SS /2 2-/ C 36SS 3/4 2-/2 P (NPT) A.88 Part Number Thermowell Pressure-Temperature and Velocity Limitations Maximum Fluid Velocity Feet Per Second Material Insertion Length-"U" 2-/2" 4-/2" 7-/2" 0-/2" 3-/2 6-/2" 9-/2" 22-/2" Brass (50) (83.5) Carbon Steel (270) (50) A.I.S & (350) (208) Monel (300) (67) The values in parentheses (00) represent safe values for water flow. Unbracketed values are for steam, air, gas and similar low density fluids. Pressure-Temperature Rating Lbs. Per Square Inch Material Temperature F Brass * * Carbon Steel A.I.S.I A.I.S.I Monel *Stainless Steel Recommended. Capillary Variations Examples Examples without Manual with Manual Description Suffix Reset Reset (-RD) Copper Units with A (added to any 302 SS Armor standard catalog) TX-H50-A MTH-G50-A-RD Stainless Steel Units With 302 SS Armor T2H-H60S-2-A T2H-H60S-2-A-RD Extra Length Capillaries Available as Special. (over 2 in length) ConsultFactory for part number, price and delivery. 32 Fruitland Avenue Los Angeles, CA Fax: See Barksdale s Standard Conditions of Sale Specifications are subject to modification at any time Bulletin #T0028-C 09/ Printed in the U.S.A. 2

9 Explosion Proof Temperature Switch Series TXR, TXL Features Explosion-proof High accuracy Line or ambient sensing UL, CSA & ATEX approved Applications Heat tracing Hydraulic power units Combustion engines Compressors Machine tools and industrial equipment Process equipment General Specifications* Accuracy: Switch: Type: Rating: Electrical Characteristics: ±% of full scale Single pole double throw (SPDT), prewired snap action 22 25/250/480 VAC All models incorporate Underwriters Laboratories, Inc. and CSA listed single pole double throw snap-action switching elements. Switches may be wired normally open or normally closed. Electrical Connection: 3/4 NPT female conduit connection. 3 pole terminal block accepts 6-0 AWG wire. Enclosure Ratings: NEMA 4, 7, 9, & IP65 Enclosure/Housing: Anodized aluminum, explosion proof, painted silver Bulb and Capillary: Material: 36L stainless steel Approvals: FM, UL file E58658, CSA - file LR Division and 2, Class I, Group B, C & D Class II, Group E, F & G, Class III. ATEX EEx d IIC, T6 (EX NEPSI GOST-R) Temperature Range: -40 to 60 F (-40 to 7 C) Ambient Temperature: -40 to 40 F (-40 to 60 C) Adjustment: External adjustment knob. Turn knob clockwise to decrease setpoint ENI/RFI: to EN 550 Vibration: 0 g s Hz, MIL-STD 202F Shock: 50 g s, 0 ms, MIL-STD 90C Standard Options: -R (suffix): Double pole single throw (DPST) relay 22 20/240/277 VAC. Contacts close on falling temperature. Relay Coil: 20 VAC, 4VA. Example: TXR-L2S-0R-Q0 Weight: 3.8 lb (.7 kg) Bulb: Capillary Length: 8 (203mm), 5/6 (8mm) dia. 0 (3m), remote mount only System Pressure (max): 300 psi without thermowell Fill: Silicone oil-filled * See Product Configurator for additional options. Media Temperature Limits -40 to 420 F (-40 to 25 C) -40 to 60 F (-40 to 7 C) Adjustable Range 25 to 325 F (-4 to 63 C) 5 to 40 F (-9 to 60 C) Differential (approximate) 0 F (5.6 C) 0 F (5.6 C) Sensing Location Line Sensing T-stat Ambient Sensing T-stat Catalog Number TXR-L2S-0-Q0 TXL-LS-Q0

10 Explosion Proof Temperature Switch Series TXR, TXL Technical Drawing 9/32-7/32 (30) Dimensions in inches (mm) Product Configurator Example TX R -L 2 S -0 -Q0 Base Configurator T X L R 2 Temperature switch NEMA 4, 7, 9 & IP65 explosion proof enclosure Limit Switch Local mount for ambient sensing Remote bulb & capillary -L 22 25/250/480 VAC S -Q0 Heat tracing model (standard) Stainless steel sensor For TXL models -0 0 ft bulb & capillary for TXR models -0R2 Wetted Material Temperature Range Bulb & Capillary Length & Switch 22A DPST relay 3 with 0 ft bulb & capillary. (For TXR models) NOTES: Use temperature range for local sensing applications 2 Use temperature range 2 for remote sensing applications 3 DPST switch, 22 20/240/277 VAC. Relay Coil: 240 Vac, 4 VA. Contacts close on falling temperature. Adjustable Range Media Temperature Limit Differential (Proof) (Approx.) Liquid Range F C F C F C Low High Low High Low High Low High Fruitland Avenue Los Angeles, CA Fax: See Barksdale s Standard Conditions of Sale Specifications are subject to modification at any time Bulletin #T0026-G 09/ Printed in the U.S.A. 2

11 Temperature General Purpose Switch Series TPR Features High accuracy NEMA 4X & IP 65 UL, CSA and CE approved Low cost Applications Heat trace Water equipment Process equipment Machine tools and industrial equipment Freeze protection General Specifications* Accuracy: Switch: Type: Rating: Electrical Characteristics: Wetted Parts: Electrical Connection: Enclosure Rating: Enclosure/Housing: ±4 F * See Product Configurator for additional options. Single pole double throw (SPDT), prewired snap action 22 25/250/480 VAC All models incorporate Underwriters Laboratories, Inc. and CSA listed single pole double throw snap-action switching elements. Switches may be wired normally open or normally closed. Tin plated copper sensor & capillary -/8 (28mm) hole for 3/4 NPT conduit hub 2, 4 AWG stranded copper wire NEMA 4X Polycarbonate (black) Bulb and Capillary: Bulb: Capillary Length: System Pressure (max): Fill: Approvals: Temperature Range: Ambient Temperature: Vibration: Shock: Weight: 3-/8 (79mm), /6 (0mm) dia. 30 (762mm) or 20 (3048mm) 300 psi without thermowell Silicone oil-filled UL listed, file E56247 CSA certified, file LR EN/RFi: to EN to 60 F (-40 to 7 C) Fixed setpoint factory set at 40 F Contact closes on decreasing temperature -30 to 40 F (-34 to 60 C) 0 g s Hz, MIL-STD 202F 50 g s, 0 ms, MIL-STD 90C. lbs. (0.5 kg) Wiring Code Lead Normally Closed Common Normally Open Circuit Blue Purple Red Media Factory Differential Catalog Temperature Preset (approximate) Number Limits -40 to 60 F 40 F 0 F (-40 to 7 C) (4.4 C) (5.6 C) TPR-LN-3X-Q0

12 General Purpose Switch Series TPR Technical Drawing Dimensions in inches (mm) Product Configurator Example T P R -L N -3X -Q0 Basic Configurator T Temperature switch -Q0 Heat tracing model Basic Configurator P Polycarbonate plastic NEMA 4X enclosure Basic Configurator R Remote bulb & capillary Bulb & Capillary Length -3X 3 foot bulb & capillary sensor -0X 0 foot bulb & capillary sensor Limit Switch -L 22 25/250/480 VAC; standard Temperature Range Range Fixed Set-point (Decreasing) F C F Low High Media Temperature Limit (Proof) C Low High Differential (Approx.) Liquid F C Wetted Material N Tin plated copper sensor 32 Fruitland Avenue Los Angeles, CA Fax: See Barksdale s Standard Conditions of Sale Specifications are subject to modification at any time Bulletin #T0025-D 09/ Printed in the U.S.A. 2

13 Temperature Temperature Switch Series THR, THL Features High accuracy Line or ambient sensing NEMA 4X & IP 65 UL, CSA and CE approved Applications Heat tracing Process equipment Machine tools and industrial equipment General Specifications* Accuracy: Switch: Type: ±% of full scale SPDT, prewired snap action Rating: 22 25/250/480 VAC Electrical All models incorporate Underwriters Characteristics: Laboratories, Inc. and CSA listed single pole double throw snap-action switching elements. Switches may be wired normally open or normally closed. Electrical Connection: 3/4 NPT female conduit connection. 3 pole terminal block accepts 4-0 AWG wire. Electrical Ratings: 22 25/250/480 VAC Enclosure Rating: NEMA 4X Enclosure/Housing: Anodized die cast aluminum Green polyurethane coated Other exposed parts: stainless steel Bulb and Capillary: Material: 36L stainless steel Approvals: UL listed, file CSA certified, file LR EMI/RFI: to EN 550 Temperature Range: 5 F F (-9 C - 63 C) Ambient See table below (media temperature limit) Temperature: Adjustment: External adjustment knob. Turn clockwise to decrease setpoint Vibration: 0 g s Hz, MIL-STD 202F Shock: Standard Options: R**(Option): R2 (Option): Weight: 50 g s, 0 ms, MIL-STD 90C DPST relay switch 22 VAC Relay coil: 20 VAC, 4VA 20/240/277 VAC Relay coil: 240 VAC, 4VA.9 lbs. (0.9 kg) Bulb: 7-3/4 (97mm), 5/6 (8mm) dia. Capillary Length: System Pressure (max): Fill: 0 (3m), remote mount 300 psi without thermowell Silicone oil-filled * See Product Configurator for additional options. ** Must specify; close on rising or falling temperature Media Adjustabl Differential Sensing Catalog Temperature Range (approximate) Location Number Limits -40 to 420 F 25 to 325 F 0 F Line Sensing THR-L2S-0X-Q0 (-40 to 25 C) (-4 to 63 C) (5.6 C) T-stat -40 to 60 F 5 to 40 F 0 F Ambient THL-LS-X-Q0 (-40 to 7 C) (-9 to 60 C) (5.6 C) Sensing T-stat Factory Set Point 25 F ± 5 decreasing 40 F ± 4 decreasing

14 Temperature Switch Series THR, THL Technical Drawing Dimensions in inches (mm) Product Configurator Example TH R -L 2 S -0X -Q0 Base Configurator TH Aluminum NEMA 4X enclosure -Q0 Heat tracing model (standard) L R 2 Local mount for ambient sensing Remote bulb & capillary Bulb & Capillary Length; Switch -X For THL models (with NEMA 4X enclosure) -0X 0 ft bulb & capillary for THR models Limit Switch -L 22 25/250/480 VAC -0R2X 22A DPST relay3, 0 ft bulb & capillary for THR models Temperature Range Range Adjustable Range Media Temperature Limit (Proof) F C F C Low High Low High Low High Low High Differential (Approx.) Liquid F C Wetted Material S Stainless steel sensor Use Temperature Range for local sensing applications 2 Use Temperature Range 2 for remote sensing applications 3 DPST switch, 22 20/240/277 VAC. Relay Coil: 240 Vac, 4 VA. Contacts close on falling temperature. 32 Fruitland Avenue Los Angeles, CA Fax: See Barksdale s Standard Conditions of Sale Specifications are subject to modification at any time Bulletin #T0024-E 09/ Printed in the U.S.A. 2

15 Compact Explosion Proof Temperature Switch T9692X Features Compact design Convenient field adjustability NEMA 4X, 7 & 9 SPDT and DPDT switch ATEX approved Class I Div I Direct or remote mount Panel mount capability 36 stainless steel NACE compliant Armored capillary Applications Offshore platforms Safety panels Chemical plants & refineries Compressor skids Instrument panels Hazardous location applications General Specifications* Accuracy: Typical Life: Switch: Electrical Ratings: Materials: Bulb, Capillary & Armor: Enclosure: Local Mount Element: Electrical Connection: * See Product Configurator for additional options. 63% of full scale million cycles SPDT, snap action, Class EE, simulated DPDT (optional) 25/250 VAC 5 30 VDC (EE class) 36 stainless steel 36 stainless steel Enclosure Ratings: NEMA 4X, 7 & series stainless steel /2 inch NPT male conduit connection 8 AWG, 8 (300 mm) free leads Approvals: ATEX: UL: CSA: Ambient Operating Temperature: CSA & ATEX: CE 008 LCIE 08 ATEX 6074X II 2 G Ex d IIC T6, -40 C < Tamb < 60 C Listed 366S, Class: I, Groups: A, B, C, D, -25 C < Tamb < 60 C Class: I, Groups: B, C, D -40 C < Tamb < 60 C -40 F to 40 F (-40 C to 60 C) UL: -3 F to 40 F (-25 C to 60 C) EMI/RFI: EN550 Vibration: 0g s Hx, MIL-STD 202 F Shock: 50g s, ms, MIL-S-90C Adjustment: Internal locking adjustment wheel, /6 hex set screw Weight: 3 lbs. maximum Wiring Code Wiring Diagram Lead Circuit # Circuit #2 (SPDT) (DPDT) Normally Closed Blue Orange Common Purple Brown Normally Open Red Yellow Ground Green NC (Blue) C (Purple) NO (Red) Ground (Green) INCR P NC (Blue) C (Purple) NO (Red) NC2 (Orange) INCR P C2 (Brown) NO2 (Yellow) Ground (Green)

16 Compact Explosion Proof Temperature Switch Technical Drawing Dimensions in inches [mm] T9692X " FREE LEADS SEE WIRE COLOR CODE CHART FOR FURTHER DETAILS /2 NPT CONDUIT CONNECTOR T U SC GRD SCREW " HEX TOOL REQUIRED 3.7 [97] MAX.9 24 /2 NPT 2X.2 5 MOUNTING HOLES MAX 94 MAX.5 38 CAPILLARY AND BULB NOT SHOWN FOR CLARITY.2 5 (ARMOR DIA.) (.06[.6] NON-ARMOR).5 3 LOCAL MOUNT OPTION ARMOR VERSION SHOWN Product Configurator Example T9692X - EE Base Configurator T9692X Temperature switch Number of Circuits - SPDT switch -2 Simulated DPDT switch (2 SPDTs) Options Blank Standard -A Stainless steel armor -SXXX -WXXX Factory preset Extra wire length (XXX=inches) Limit Switch EE GH Silver contacts 25V/250 VAC; 5 30 VDC Gold contacts 25/250 VAC Temperature Ranges Adjustable Range Approx. Deadband 2 Actuation Value Media Temperature Limits Proof Temperature - -0 F to 0 F (-23 C to 43 C) 5 F to 30 F (2.8 C to 6.7 C) -40 F to 60 F (-40 C to 7 C) 60 F (7 C) F to 220 F (35 C to 04 C) 5 F to 30 F (2.8 C to 6.7 C) 40 F to 270 F (4 C to 32 C) 270 F (32 C) F to 330 F (82 C to 65 C) 5 F to 30 F (2.8 C to 6.7 C) 70 F to 380 F (2 C to 93 C) 380 F (93 C) Capillary Length ft (.8 meters) ft (2.7 meters) ft (3.7 meters) -00 Local mount Not available in local mount 2 Deadband values indicated when used with the EE limit switch 32 Fruitland Avenue Los Angeles, CA % Fax: See Barksdale s Standard Conditions of Sale Specifications are subject to modification at any time Bulletin #T0029-A 0/ Printed in the U.S.A. 2

17 Explosion Proof Temperature Switches Features Explosion-proof for hazardous locations High accuracy Remote, local or ambient sensing UL, CSA & ATEX approved NEMA 4, 7, 9 & IP65 Applications Oil & gas Heat tracing Printing machinery Compressors Process equipment Machine tools and industrial equipment Series TX, T2X, LX LX T2X General Specifications* Accuracy: Switch: Single Setting: Dual Setting: Electrical Characteristics: Wetted Parts: Electrical Connection: Electrical Ratings: Enclosure/Housing: * See Product Configurator for additional options. Wiring Code ±% of mid-60% of full range. At constant ambient +/- 0.5% of full scale. One () single pole double throw (SPDT) circuit. Two (2) independent single pole double throw (SPDT) circuits. All models incorporate Underwriters Laboratories, Inc. and CSA listed single pole double throw snap-action switching elements. Switches may be wired normally open or normally closed. 304 stainless steel Single: 3-pin terminal strip Dual: 6-pin terminal strip AC value at 75% power factor 0 amps 25, 250 volts AC, 3 amps 480 volts AC. Automatically reset by snap-action of switch. Designed for hazardous locations: Class I, Division & 2 NEMA 4, 7, 9 & IP65 tamper-proof external adjustment, enclosed terminal strip. Lead Circuit # Circuit #2 Normally Closed Blue Orange Common Purple Brown Normally Open Red Yellow Local Mount: Bulb & Capillary: Approvals: UL (standard): CSA (standard): ATEX (optional): Temperature Range: Adjustment: Standard Options/ Modifications: Weight: Wiring Diagram NO (Red) C (Purple) NC (Blue) Immersion length 2-/6 inches 6 and 2 foot length standard. Underwriters Laboratories, Inc. and Canadian Standard Assoc. are listed under Temperature indicating and regulating equipment, for use in hazardous locations, Class I, Groups B, C and D; Class II, Groups E, F and G. File No. E58658, Guide No. XBDV File No. LR34556, Guide 400-E-O.8. Class EX models are ATEX certified per ISSeP 03 ATEX 2 & maked as follows: CE 008 II2 GD EEx d IIC T6 T85 C See product configurator Tamper resistant external adjustment. Turn knob clockwise to increase setpoint. For thermowels, split nuts and union connections, see accessory pages. Single - approximate 3.0 lbs. Dual - approximate 7.0 lbs. T NO (Red) C (Purple) NC (Blue) NO (Yellow) C (Brown) NC (Orange) T

18 Explosion Proof Temperature Switches Series TX, T2X, LX Technical Drawing LX TX Dimensions in inches (mm) Product Configurator Hermetically Sealed H Sensing Type T L Hermetically sealed limit switch option - Class I, Division II (requires AA, CC or HH limit switch) Remote bulb & capillary Local mount Example H T X -HH 25 S -2 -A Wetted Material Options -RD -EX -Sxxx Manual reset (must use when selecting G limit switch option) 3 Only available on T2X ATEX certification Factory pre-set (consult factory) Set Point Single setpoint (SPDT) 2 Dual setpoint (2 SPDT) Enclosure X Limit Switch 2 -H 0 25/250 VAC; VAC (standard) -B -G 0 25/250/480 VAC; VAC; VDC; VDC 0 25/250/480 VAC; VAC; VDC; MANUAL RESET (only available for T2X) 3 -J 0 25/250 VAC; VAC (with elastomer boot) -L -M -S -GH -AA -CC -HH NEMA 4, 7, 9 & IP65 explosion proof enclosure 5 25/250/480 VAC; VDC; VDC 0 25/250 VAC; VAC; VDC; VDC 5 25/250/480 VAC; VDC; adjustable differential 4 25VAC; gold contacts Hermetically sealed; 4 25/250 VAC Hermetically sealed; 0 25/250 VAC Hermetically sealed; 5 25/250 VAC Blank S Capillary Length Blank Not available with local mount version. 2 Changing limit switch will effect deadband; See sales drawing 3 When selecting the manual reset option on dual setting switches (T2X), the manual reset limit switch will be on the high circuit. The low circuit limit switch must be specified by the customer. Only available with T2X. Brass sensor 304 stainless steel (6ft capillary for remote sensing models) Blank = 6 foot capillary -2 2 ft capillary ft stainless steel capillary with armor (use with the A options) Temperature Range 32 Fruitland Avenue Los Angeles, CA Fax: Thermowell (Local Mount only) 36 stainless steel thermowell -WS (local mount only) Armor Option (Bulb & Capillary only) See Barksdale s Standard Conditions of Sale Specifications are subject to modification at any time Bulletin #T0022-G / Printed in the U.S.A. 2 Blank Blank if not required -A 302 stainless steel armor Remote sensor ranges Adjustable Range Media Temperature Limit (Proof) Differential (Approx.) 2 Range Low High Low High Low High Low High F C F +50 F -45 C +66 C -00 F +200 F -73 C +93 C to 2.5 to F +250 F +0 C +2 C -00 F +300 F -73 C +49 C to 2.5 to F +350 F +66 C +77 C -00 F +400 F -73 C +205 C to 2.5 to F +440 F +49 C +227 C 0 F +650 F -8 C +343 C 2 to 4. to F +600 F +60 C +36 C 0 F +650 F -8 C +343 C 2 to 4. to 2.2 Local mount sensor ranges Adjustable Range Media Temperature Limit (Proof) Differential (Approx.) 2 Range Low High Low High Low High Low High F C F +75 F -45 C +24 C -00 F +250 F -73 C +2 C to 3.5 to F +40 F +9 C +60 C -00 F +250 F -73 C +2 C to 3.5 to F +200 F +24 C +93 C -00 F +250 F -73 C +2 C to 3.5 to F +225 F +38 C +07 C -00 F +400 F -73 C +205 C 6 to to F +200 F -45 C +93 C -00 F +250 F -73 C +2 C to 3.5 to F +350 F +38 C +77 C -00 F +400 F -73 C +205 C 6 to to F +450 F +66 C +232 C 0 F +500 F -8 C +260 C 3 to 6.6 to When selecting the S adjustable differential limit switch option on a dual setting switch (T2X), a standard H switch will be paired with an S switch. Dual S pricing will apply.

19 Remote Mount Temperature Switches Series MTH, T2H Features Reliable & accurate Ambient compensated NEMA 4, 3 and IP 65 UL, CSA & CE approved Single or dual switching Applications Marine & shipbuilding Railroad Oil & gas Medical Compressors Water equipment Process equipment Machine tools and industrial equipment General Specifications* Accuracy: Switch: Electrical Characteristics: Wetted Parts: Electrical Connection: Electrical Ratings: Enclosure/Housing: * See Product Configurator for additional options. ±% of mid-60% of full range. At constant ambient ±0.5% of full scale. One () SPDT or two (2) independent SPDT circuits All models incorporate Underwriters Laboratories, Inc. and CSA listed single pole double throw snap-action switching elements. Switches may be wired normally open or normally closed. Copper or 304 stainless steel Single: 3-Pin terminal strip Dual: 6-Pin terminal strip AC value at 75% power factor 0 25, 250 volts AC, volts AC. Automatically reset by snap-action of switch. Watertight and dust-tight indoor and outdoor (NEMA 4)/oil-tight and dust-tight indoor (NEMA 3). Bulb & Capillary: Approvals: UL: CSA: Temperature Range: Adjustment: Weight: 6 and 2 foot length standard. See operating characteristics and product configurator. Underwriters Laboratories, Inc. and Canadian Standard Assoc. are listed under temperature indicating and regulating equipment. File No. E56247, Guide No. XAPX File No. LR34555, Guide 400-E-O Class 483 See product configurator Tamper resistant external adjustment. Turn knob clockwise to increase setpoint. Single: approximate.5 lbs. Dual: approximate 3.0 lbs. Wiring Code Wiring Diagram Lead Circuit # Circuit #2 Normally Closed Blue Orange Common Purple Brown Normally Open Red Yellow NO (Red) C (Purple) NC (Blue) T NO (Red) C (Purple) NC (Blue) NO (Yellow) C (Brown) NC (Orange) T MTH T2H

20 Remote Mount Temperature Switches Series MTH, T2H Technical Drawing T2H MTH COPPER 3 6 Dimensions in inches (mm) Product Configurator Example H M T H -HH 54 S -2 -A -FX Options H Blank M Blank Switch T T2 H Hermetically sealed limit switch option - Class I, Division II (requires AA, CC or HH limit switch) Standard Enclosure Single set point switch models Dual switch models Single SPDT Dual switch 2 independent SPDT NEMA 4 & IP65 enclosure NOTES: Use G limit switch for single set point models that need this option. When selecting the manual reset option on dual setting switches (T2H), the manual reset limit switch will be on the high circuit. The low circuit limit switch must be specified by the customer. 2 Changing limit switch will effect dead band; See sales drawing. 3 When selecting the S adjustable differential limit switch option on a dual setting switch (T2H), a standard H switch will be paired with an S switch. Dual S pricing will apply. 4 Add S wetted material adder to this. No additional adder from armor options table. Limit Switch 2 -H 0 25/250 VAC; VAC (standard) -B 0 25/250/480 VAC; VAC; VDC; VDC 0 25/250/480 VAC; VAC; 0.4 -G 25 VDC; MANUAL RESET -J 0 25/250 VAC; VAC (with elastomer boot) -L 5 25/250/480 VAC; VDC; VDC -M 0 25/250 VAC; VAC; VDC; VDC -S 5 25/250/480 VAC; VDC; Adjustable differential 3 -GH 25VAC; gold contacts -AA Hermetically sealed; 4 25/250 VAC -CC Hermetically sealed; 0 25/250 VAC -HH Hermetically sealed; 5 25/250 VAC Temperature Range Range Adjustable Range Media Temperature Limit (Proof) F Low High C Low High F Low High C Low High Differential 2 (Approx.) Liquid F C to 2.5 to to 2.5 to to 2.5 to to 4. to to 4. to 2.2 Calibrated Dial Adjustment Calibrated 5 Subdivision 200 Span 5 Subdivision 40 Span 0 Subdivision 280 Span 32 Fruitland Avenue Los Angeles, CA Fax: RD Manual reset Wetted Material See Barksdale s Standard Conditions of Sale Specifications are subject to modification at any time Bulletin #T002-G / Printed in the U.S.A. 2 -FX -SXXX Blank -A Blank S NEMA 4X enclosure Factory pre-set (consult factory) Armor Options Blank if not required 302 stainless steel armor (standard) Capillary Length -2 2 foot capillary foot stainless steel 4 [use -A (armor) and S (stainless steel wetted material) options] 6 foot copper capillary 6 foot 304 stainless steel capillary

21 Temperature Bi-Metallic Switch Series MLS Features Bi-metallic sensor Compact design NEMA 4 & IP65 One piece design Applications Air compressors Medical compressors Process equipment Water treatment Mining Machine tools and industrial equipment General Specifications* Accuracy: Switch: Wetted Parts: Electrical Connection: Electrical Ratings: Enclosure/Housing Process Connection: Conduit Connection: Proof Pressure: Cycle Life: See adjacent table SPST-NO or SPST-NC Brass 8, 8 AWG PTFE free leads 25 Vac; 250 Vac NEMA 4, IP65 /2 NPT /2 NPT 500 psi 00,000 cycles Approvals: CE qualified UL and CSA Temperature Range: 50 F F Proof Temperature: 340 F Warranty: Weight: year 0.5 lb. * See product configurator for additional options. Differential depends on service conditions and test methods

22 Bi-Metallic Switch Series MLS Technical Drawing Number Shown = Set Point /2 NPT 7/8 HEX /2 NPT TEMPERATURE SENSING PROBE /6 (7.8) 8 AWG. BLACK PTFE LEADS 8 LONG STANDARD -/2 (38.) 2-/8 (53.3) 3-/2 (REF.) (88.9) Dimensions in inches (mm) Product Configurator Example ML S -30 -I -C -W36 Prefix ML Miniature local thermowell Switch Single SPST switch point Housing S Stripped model Option -WXXX Extra wire length (XXX = inches) Setpoint* ºF setpoint ºF setpoint ºF setpoint ºF setpoint ºF setpoint ºF setpoint ºF setpoint ºF setpoint ºF setpoint ºF setpoint Set Point Direction -D Decreasing (falling) temperature -I Increasing (rising) temperature Contact Form -O Normally open -C Normally closed * NOTE: Consult factory for ranges not listed. Minumum order quantity - 20 pieces for non-standard ranges. Ranges specified in 5 increments. Example: -250 = 250 F 32 Fruitland Avenue Los Angeles, CA Fax: See Barksdale s Standard Conditions of Sale Specifications are subject to modification at any time Bulletin #T0023-C 09/ Printed in the U.S.A. 2

23 Local Mount Temperature Switches Features Reliable & accurate Local sensing NEMA 4 & IP 65 UL, CSA & CE approved Single or dual switching Applications Oil & gas Mining Tanks and reservoirs Compressors Plastic machinery Factory automation Process equipment Machine tools and industrial equipment MLH, L2H General Specifications* Accuracy: Switch: Electrical Characteristics: Wetted Parts: Electrical Connection: Electrical Ratings: Enclosure/Housing: Local Mount: * See Product Configurator for additional options. ±% of mid-60% of full range. At constant ambient ±0.5% of full scale. Single: SPDT Dual switching: 2 independent SPDT circuits All models incorporate Underwriters Laboratories, Inc. and CSA listed single pole double throw snap-action switching elements. Switches may be wired normally open or normally closed. Brass or 304 stainless steel Single: 3-pin terminal strip Dual: 6-pin terminal strip AC value at 75% power factor 0 amps 25, 250 volts AC, 3 amps 480 volts AC. Automatically reset by snap-action of switch. Water-tight and dust-tight indoor and outdoor (NEMA 4) / oil-tight and dust-tight indoor (NEMA 3). Immersion length 2-/6 inches Approvals/Listings: UL: CSA: Temperature Range: Adjustment: Weight: Underwriters Laboratories, Inc. and Canadian Standard Assoc. are listed under temperature indicating and regulating equipment. File No. E56247, Guide No. XAPX File No. LR34555, Guide 400-E-O Class 483 See product configurator. Tamper resistant external adjustment. Turn knob clockwise to increase setpoint. Single: approximate.5 lbs. Dual: approximate 3.0 lbs. Wiring Code Wiring Diagram Single Dual Lead Circuit # Circuit #2 Normally Closed Blue Orange Common Purple Brown Normally Open Red Yellow NO (Red) C (Purple) NC (Blue) T NO (Red) C (Purple) NC (Blue) NO (Yellow) C (Brown) NC (Orange) MLH L2H T

24 Local Mount Temperature Switches Technical Drawing MLH, L2H L2H -5/8 (4.2) MLH 7 Dimensions in inches (mm) Product Configurator Example H M L H -HH 202 S -WS -FX H Blank M Blank Hermetically sealed limit switch option - Class I, Division II (requires AA, CC, GH or HH limit switch) Standard Single switch models Dual switch models Sensor Switch L Single set point (SPDT) L2 Dual set point (2 SPDT) Enclosure NEMA 4 & IP65 H enclosure Limit Switch 2 NOTES: Use G limit switch for single set point models that need this option. When selecting the manual reset option on dual setting switches (L2H), the manual reset limit switch will be on the high circuit. The low circuit limit switch must be specified by the customer. 2 Changing limit switch will effect dead band; See sales drawing. 3 When selecting the S adjustable differential limit switch option on a dual setting switch (L2H), a standard H switch will be paired with an S switch. Dual S pricing will apply. 4 Not available with hermetically sealed limit switches -H 0 25/250 VAC; VAC (standard) -B 0 25/250/480 VAC; VAC; VDC; VDC -G 0 25/250/480 VAC; VAC; VDC; MANUAL RESET -J 0 25/250 VAC; VAC (with elastomer boot) -L 5 25/250/480 VAC; VDC; VDC -M 0 25/250 VAC; VAC; VDC; VDC -S 5 25/250/480 VAC; VDC; Adjustable differential 3 -GH 25VAC; Gold Contacts -AA Hermetically sealed; 4 25/250 VAC -CC Hermetically sealed; 0 25/250 VAC -HH Hermetically sealed; 5 25/250 VAC -GH Hermetically selaed; 25 VAC; gold contacts Range 32 Fruitland Avenue Los Angeles, CA Fax: Options See Barksdale s Standard Conditions of Sale Specifications are subject to modification at any time Bulletin #T0020-G / Printed in the U.S.A. 2 -RD -FX -SXXX Thermowell -W -WS Manual reset (use with G limit switch), 4 NEMA 4X enclosure Factory preset Brass local mount thermowell 36 stainless steel local mount thermowell Wetted Material Blank Blank if brass 304 stainless steel S sensor Adjustable Range Media Temperature Limit (Proof) Differential (Approx.) 2 Low High Low High Low High Low High F C F +75 F -45 C +24 C -00 F +250 F -73 C +2 C to 3.5 to F +40 F -9 C +60 C -00 F +250 F -73 C +2 C to 3.5 to F +200 F +24 C +93 C -00 F +250 F -73 C +2 C to 3.5 to F +225 F +38 C +07 C -00 F +400 F -73 C +205 C to 3.5 to F +200 F -45 C +93 C -00 F +250 F -73 C +2 C to 3.5 to F +350 F +38 C +77 C -00 F +400 F -73 C +205 C to 3.5 to F +450 F +66 C +232 C 0 F +500 F -8 C +260 C 3 to 6.6 to 3.3

25 Global Presence Global Presence Barksdale Inc. 32 Fruitland Ave. Los Angeles, CA U.S.A. Phone: (800) Fax: (323) Barksdale GmbH Dorn-Assenheimer Strasse Reichelsheim, Germany Phone: (49) (main office) (49) (sales) Fax: (49) / Barksdale GmbH Dorn-Assenheimer Strasse Reichelsheim, Germany Phone: (49) (main office) (49) (sales) Fax: (49) / Barksdale India SF- 43, Ansal Fortune Arcade Sector 8 India-2030 Noida Phone: Fax: manojsingh@barksdale.in

Temperature Products. Temperature Products

Temperature Products. Temperature Products Temperature Products Temperature Products u Electronic Products u Pressure Transducers u Mechanical Pressure Products u Valves & Regulators u Temperature Products u Level Products u Air Suspension Valves

More information

Operating Instructions Mechanical Temperature Switches ML1H,MT1H,L2H,T2H,L1X/L1X-EX,T1X/T1X-EX,T2X/T2X-EX

Operating Instructions Mechanical Temperature Switches ML1H,MT1H,L2H,T2H,L1X/L1X-EX,T1X/T1X-EX,T2X/T2X-EX ATEX Type Certification marking for type L1X-EX, T1X-EX, T2X-EX Type of protection "d" explosion-proof enclosure Operating Instructions Mechanical Temperature Switches ML1H,MT1H,L2H,T2H,L1X/L1X-EX,T1X/T1X-EX,T2X/T2X-EX

More information

Fluid Power Fluid Power

Fluid Power Fluid Power Fluid Power Fluid Power Control Control every move Barksdale State-of-the-Art Solutions Barksdale State-of-the-Art Solutions Today s markets demand flexible and dynamic suppliers of innovative products,

More information

Product overview. Product overview. Control. Control. every move. Pressure Temperature Level Flow

Product overview. Product overview. Control. Control. every move. Pressure Temperature Level Flow Product overview Product overview Control Control every move Pressure Temperature Level Flow Barksdale Controls The business of critical controls Market-focused. Technology-driven. Customer-intimate. These

More information

UNITED ELECTRIC 100 Series, Pressure, Vacuum, Diff. Pressure & Temp. Switches Adjustable Ranges 30 Vac to 5000 PSI, -180 to 650 o F

UNITED ELECTRIC 100 Series, Pressure, Vacuum, Diff. Pressure & Temp. Switches Adjustable Ranges 30 Vac to 5000 PSI, -180 to 650 o F UNITED ELECTRIC 100 Series, Pressure, Vacuum, Diff. Pressure & Temp. Switches Adjustable Ranges 30 Vac to 5000 PSI, -180 to 650 o F DESCRIPTION The 100 Series is a cost-effective pressure and temperature

More information

Product overview. Product overview. Control. Control. every move. Pressure Temperature Level Flow

Product overview. Product overview. Control. Control. every move. Pressure Temperature Level Flow Product overview Product overview Control Control every move Pressure Temperature Level Flow Global Presence Global Presence Barksdale Inc. 3211 Fruitland Avenue Los Angeles, CA-90058-0843 U.S.A. Phone:

More information

Series 1. Series 1 Pressure Switch. Pressure Switches Inc. Quality Pressure Solutions. Pressure Switches 1 G 10 N Key Features.

Series 1. Series 1 Pressure Switch. Pressure Switches Inc. Quality Pressure Solutions. Pressure Switches 1 G 10 N Key Features. Model 1A 1C 1G 1Z 1P 1H Inc. Series 1 Series 1 Pressure Switch High, Low, Differential & Vacuum Pressure Switch options available All Anodized Aluminum Construction Multiple s Available UL & cul Approved

More information

9012G Pressure and 9016G Vacuum Switches

9012G Pressure and 9016G Vacuum Switches Selection Guide 90G and 906G Vacuum Switches Type of installation Control circuits Power circuits Applications Media controlled Type of operation Air, water, hydraulic oils, () gases, steam Fixed differential:

More information

^ % P-SERIES Temperature Switches. Switches for -30 through 510 F with Adjustable Set Points and Fixed or Adjustable Deadband

^ % P-SERIES Temperature Switches. Switches for -30 through 510 F with Adjustable Set Points and Fixed or Adjustable Deadband P-SERIES Temperature Switches Switches for -30 through 5 F with Adjustable Set Points and Fixed or Adjustable Features: Set point repeatability, + F (/2 C). All wiring terminals, adjustments and visual

More information

E. Clark & Associates 10 Brent Drive Hudson, MA Tel. 978 / Fax 978 / Two Switch Output Hex Screw Adjustment

E. Clark & Associates 10 Brent Drive Hudson, MA Tel. 978 / Fax 978 / Two Switch Output Hex Screw Adjustment CLARK SOLUTIONS 400 Series, Pressure, Vacuum, Diff. Pressure & Temp. Switches 1,2 & 3 Switch output, Adjustable Ranges 30 Vac to 6000 PSI, -180 to 650 o F DESCRIPTION The 400 Series is a versatile family

More information

Data Sheet. A-Series Miniature Watertight Pressure Switches. Factory set or field adjustable

Data Sheet. A-Series Miniature Watertight Pressure Switches. Factory set or field adjustable FEATURES Compact size 36 stainless steel construction Pressure ranges from vacuum to 5,000 psi Factory set or field adjustable setpoints Wide operating temperature range ( 40 C to 00 C) Precision snap-acting

More information

Switches for Pressure to 8000 psig, Vacuum, Differential, or Level Control with General Purpose, Watertight or Explosion-Proof Enclosures

Switches for Pressure to 8000 psig, Vacuum, Differential, or Level Control with General Purpose, Watertight or Explosion-Proof Enclosures S-SERIES Pressure Switches Switches for Pressure to 8000 psig, Vacuum, Differential, or Level Control with, or s Features: Set point repeatability, +1% of operating range. All wiring terminals, adjustments

More information

Mini temperature switch Stainless steel switch enclosure Model TXS

Mini temperature switch Stainless steel switch enclosure Model TXS Mechatronic temperature measurement Mini temperature switch Stainless steel switch enclosure Model TXS WIKA data sheet TV 31.70 Process Mini Series Applications Temperature monitoring and control of processes

More information

u Electronic Products u Pressure Transducers u Mechanical Pressure Products u Valves & Regulators u Temperature Products u Level Products u Air

u Electronic Products u Pressure Transducers u Mechanical Pressure Products u Valves & Regulators u Temperature Products u Level Products u Air Air Suspension Air Suspension Valves Valves u Electronic Products u Pressure Transducers u Mechanical Pressure Products u Valves & Regulators u Temperature Products u Level Products u Air Suspension Valves

More information

Data Sheet. A-Series Miniature Watertight Pressure Switches

Data Sheet. A-Series Miniature Watertight Pressure Switches A-Series Miniature Watertight Pressure Switches FEATURES Compact size 36 Stainless steel construction Pressure ranges from vacuum to 000 bar (5.000 psi) Factory set or field adjustable setpoints Wide operating

More information

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter BULLETIN NO. 220/11 (SUPERSEDES BULLETIN NO. 220/06) Mid-West Instrument Piston Type Model 220 Hazardous Locations Indicating / Non-Indicating Differential Pressure Switch or Transmitter Low cost piston

More information

PISTON STYLE GAUGE. Mid-West Instrument

PISTON STYLE GAUGE. Mid-West Instrument PISTON STYLE GAUGE Mid-West Instrument 1 BULLETIN NO. 120/11 (SUPERSEDES BULLETIN NO. 120/02) Mid-West Instrument Piston Type Differential Pressure Gauges Switches & Transmitters Model 120 A low cost differential

More information

Type E-10, E-11 Hazardous Area Explosion-proof Transmitters

Type E-10, E-11 Hazardous Area Explosion-proof Transmitters Electronic Pressure Catalog > Hazardous Area > E-10, E-11 Type E-10, E-11 Hazardous Area Explosion-proof Transmitters Meets ANSI / ISA 12.27.01-2003 single seal requirements - no dual seal required Applications

More information

Pressure Controller. Cataloge K Code Characteristics Index. K00-2 Pressure Controller Brief Introduction

Pressure Controller. Cataloge K Code Characteristics Index. K00-2 Pressure Controller Brief Introduction K Pressure Controller Cataloge Code Characteristics Index K00-2 Pressure Controller Brief Introduction KC32 Screw Tube Differential Pressure Controller K01 KY10 Bellows Type Differential Pressure Controller

More information

Compact temperature switch Model TCS

Compact temperature switch Model TCS Mechatronic temperature measurement Compact temperature switch Model TCS WIKA data sheet TV 31.64 Process Compact Series Applications Temperature monitoring and control of processes Safety-critical applications

More information

Mechanical Pressure Products

Mechanical Pressure Products Mechanical Pressure Products Mechanical Pressure Products u Electronic Products u Pressure Transducers u Mechanical Pressure Products u Valves & Regulators u Temperature Products u Level Products u Air

More information

Mid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

Mid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter BULLETIN NO. 240/11 (SUPERSEDES BULLETIN NO. 240/06) Mid-West Instrument Diaphragm Type Model 240 Hazardous Locations Indicating / Non-Indicating Differential Pressure Switch or Transmitter Field wireable

More information

Compact differential pressure switch Models DC, DCC

Compact differential pressure switch Models DC, DCC Mechatronic pressure measurement Compact differential pressure switch Models DC, DCC WIKA data sheet PV 35.40 Process Compact Series Applications Differential pressure monitoring and control of processes

More information

Bourdon Tube Pressure Switches

Bourdon Tube Pressure Switches DA /DS Bourdon Tube es Visible setpoint, adjustable deadband, snap action switch pressure ranges to 000 psi Weather-Proof Types DAW, DSW, DRW -/1 2-1/1 REAR MOUNTING FLANGE ().20 DIA. HOLES AT 120 ON -1/2

More information

Switches. SERIES FEATURE ACTUATION MAX RATING SEAL RATING MOUNTING CIRCUITRY 115VAC, 28VDC)

Switches. SERIES FEATURE ACTUATION MAX RATING SEAL RATING MOUNTING CIRCUITRY 115VAC, 28VDC) SWITCH SELECTION GUIDE Toggle Switches SERIES FEATURE ACTUATION MAX RATING SEAL RATING MOUNTING CIRCUITRY (Resistive @ 115VAC, 28VDC) T1 2 or 3 Position, Momentary, 8A MIL-PRF-83731 15/32" or 1/4" dia.

More information

VACUUM A RESOURCE FOR EVERYONE

VACUUM A RESOURCE FOR EVERYONE Vacuum grippers VACUUM PRODUCTS INNOVATORS IN VACUUM TECHNOLOGY CATALOG VERSION 5.0 VACUUM A RESOURCE FOR EVERYONE www.piab.com Accessories Suction cups Vacuum pumps PVA VACUUM SWITCHES, INDUCTIVE UNIVERSAL

More information

PISTON STYLE GAUGE. For Installation and Operation Manuals Please Visit: Mid-West Instrument

PISTON STYLE GAUGE. For Installation and Operation Manuals Please Visit:   Mid-West Instrument PISTON STYLE GAUGE For Installation and Operation Manuals Please Visit: www.midwestinstrument.com/literature Mid-West Instrument BULLETIN NO. 120/11 (SUPERSEDES BULLETIN NO. 120/02) Mid-West Instrument

More information

Palmer Circular Chart Recorders

Palmer Circular Chart Recorders Palmer Circular Chart Recorders Pressure & Temperature Recorders Designed for indoor or outdoor use, our recorders provide long service life, even in harsh conditions. Internal Assemblies, Clocks and Parts

More information

PPT 802, Proximity Probe Transducer System

PPT 802, Proximity Probe Transducer System PPT 802, Proximity Probe Transducer System PPH 080 : Proximity Probe Head PEC 036 : Probe Extension Cable PRD 020 : Proximity Probe Driver Feature Non-contacting measurement system based on eddy current

More information

37T Series Moisture Resistant Temperature Controls

37T Series Moisture Resistant Temperature Controls 37T Series Moisture Resistant Temperature Controls Moisture Resistant Temperature Control The 37T series of 3/4 (19mm) bimetal disc temperature controls from Therm-O-Disc offers proven reliability in a

More information

short form catalog SFC 07

short form catalog SFC 07 short form catalog Electronic and Electromechanical Switches for Pressure, Differential Pressure, and Temperature Pressure Transmitters and Transducers Industrial Temperature Sensors SFC 07 is a privately

More information

Mid-West Instrument. Diaphragm Type Differential Pressure Gauge & Switch Model 130. Shown here with Range 0-5 H2O

Mid-West Instrument. Diaphragm Type Differential Pressure Gauge & Switch Model 130. Shown here with Range 0-5 H2O Diaphragm Type Differential Pressure Gauge & Switch BULLETIN NO. 130/11 (SUPERSEDES BULLETIN NO. 130/02) is a rugged general purpose differential pressure gauge with a 4-1/2" round dial. Common Applications:

More information

SP/SF Series Flow Switches

SP/SF Series Flow Switches ISO-9001:2000 certified SP/SF Series Flow Switches More than just another level measurement company. Aplus Finetek Sensor, Inc. PRODUCT INTRODUCTION SP SERIES OPERATING PRINCIPLE SP SERIES The SP Series

More information

Engineering Information. Solenoid Valves Principles of Operation. Solenoid Valves. Direct Acting Valves (Figures 1A, 1B)

Engineering Information. Solenoid Valves Principles of Operation. Solenoid Valves. Direct Acting Valves (Figures 1A, 1B) 4 Engineering Information Principles of Operation A solenoid valve is a combination of two basic functional units: A solenoid (electromagnet) with its core A valve body containing one or more orifices

More information

Mini pressure switch Stainless steel switch enclosure Model PXS

Mini pressure switch Stainless steel switch enclosure Model PXS Mechatronic pressure measurement Mini pressure switch Stainless steel switch enclosure Model PXS WIKA data sheet PV 34.36 Process Mini Series Applications Pressure monitoring and control of processes Safety-critical

More information

Miniature pressure switch, flameproof enclosure Ex d For the process industry Model PXA

Miniature pressure switch, flameproof enclosure Ex d For the process industry Model PXA Mechatronic pressure measurement Miniature pressure switch, flameproof enclosure Ex d For the process industry Model PXA WIKA data sheet PV 34.38 Applications Pressure monitoring and control of processes

More information

Pressure Switch with Gauge for Pressure

Pressure Switch with Gauge for Pressure Pressure Switch with Gauge for Pressure General Specifications: Pressure Gauge Assembly for the medical gas alarm system shall incorporate a U.L. Listed single pole double throw snap-action micro switch.

More information

P70, P72, and P170 Controls for Low Pressure Applications

P70, P72, and P170 Controls for Low Pressure Applications Master Catalog 125 Pressure Controls Section P Product/Technical Bulletin Issue Date 0900 P70, P72, and P170 Controls for Low Pressure Applications The P70, P72, and P170 controls for low pressure applications

More information

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries Product Data Sheet January 214 813-1-475, Rev FA Rosemount 875WA Magnetic Flowmeter System For Water and Wastewater Industries THE 875WA MAGNETIC FLOWMETER Rosemount reliability in a customized offering

More information

Switch to. Generation NEW Electronic Level. One Series for. Pressure Temperature Level

Switch to. Generation NEW Electronic Level. One Series for. Pressure Temperature Level Switch to Generation 000 NEW Electronic Level One Series for Temperature Level Quality by design Generation 000 BPS000 / BTS000 / BLS000 Wide range of performance Simple configuration allows customers

More information

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 120

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 120 BULLETIN NO. 120/11 (SUPERSEDES BULLETIN NO. 120/02) Piston Type Differential Pressure Gauges Switches & Transmitters A low cost differential pressure gauge for use in measuring the pressure drop across

More information

Technical Datasheet. GR Series - Flameproof Pressure Switch Models: GR2 & GR4. GR Series. Key Features. Series Overview. Product applications

Technical Datasheet. GR Series - Flameproof Pressure Switch Models: GR2 & GR4. GR Series. Key Features. Series Overview. Product applications Technical Datasheet - Flameproof Pressure Switch Key Features Compact and rugged design. Weatherproof IP66/NEMA 4. ATEX Flameproof CENELEC EEx d IIC option. ATEX Intrinsically Safe ATEX Ex ia IIC option.

More information

Mechanical Pressure Switches. Catalogue. Mechanical Pressure Switches. Control. Overview. every move

Mechanical Pressure Switches. Catalogue. Mechanical Pressure Switches. Control. Overview. every move Mechanical Pressure Switches Catalogue Mechanical Pressure Switches Overview Control every move Content Content Overview 4 Introduction 4 Metal Diaphragm 6 Bourdon Tube 7 Compact 8 Diaphragm Seal Piston

More information

Quick Reference Charts

Quick Reference Charts Quick Reference Charts Adjustable Pressure Switches 0" to 40" H 2 O 7" H 2 O to 15 psig.5 to 1900 psig 35 to 2300 psig 2.3 to 2800 psig 14 to 10000 psig ALUM. STAIN. MONEL BUNA N STAIN. TANTLM. Compact

More information

System 350 P352AB Electronic Pressure Control Series

System 350 P352AB Electronic Pressure Control Series System 350 P352AB Electronic Pressure Control Series System 350 Product Guide 930 Basic Controls Section Product/Technical Bulletin P352AB Issue Date 0200 The P352AB controls are On/Off electronic pressure

More information

J 6 Se r i e s. Pressure and Vacuum switches. features

J 6 Se r i e s. Pressure and Vacuum switches. features J 6 S er i es J 6 Se r i e s Pressure and Vacuum switches features Gasketed, Die Cast Aluminum Enclosure with Epoxy Coating SPDT Switch Output Adjustable Deadband Option Sealed, Isolated Metal Bellows

More information

Compact pressure switch Model PCS

Compact pressure switch Model PCS Mechatronic pressure measurement Compact pressure switch Model PCS WIKA data sheet PV 33.30 for further approvals see page 4 Process Compact Series Applications Pressure monitoring and control of processes

More information

Vibralert Mechanical Switch Model 5550

Vibralert Mechanical Switch Model 5550 Vibralert Mechanical Switch Model 5550 APPLICATION TIPS -Lowest cost vibration protection; -Baseplates available to accomodate most previous Metrix or competitor s switch models for easy retrofit. -Watertight

More information

Gas-actuated temperature switch Stainless steel switch enclosure Model TWG

Gas-actuated temperature switch Stainless steel switch enclosure Model TWG Mechatronic Electrical temperature measurement Gas-actuated temperature switch Stainless steel switch enclosure Model TWG WIKA data sheet TV 31.60 Process Performance Series Applications Temperature monitoring

More information

BULLETIN NO.ELEC IM121/10A Replaces IM121/09A

BULLETIN NO.ELEC IM121/10A Replaces IM121/09A Mid-West Instrument BULLETIN NO.ELEC IM121/10A Replaces IM121/09A INSPECTION Model 121 Indicating Differential Pressure Switch / Transmitter Electrical: Installation and Operating Instructions Upon receipt

More information

CAPSU-PHOTOHELIC PRESSURE SWITCH/GAGE*

CAPSU-PHOTOHELIC PRESSURE SWITCH/GAGE* CAPSU-PHOTOHELIC PRESSURE SWITCH/GAGE* Specifications - Installation and Operating Instructions Bulletin B-34 Series 43000 CAPSU-Photohelic Switch/Gage The CAPSU-Photohelic Switch/Gage is a most versatile,

More information

Introduction. Series P100. Encapsulated Pressure Control. Auto-reset Standard Duty and Heavy Duty. Manual reset Standard Duty. Feature and Benefits

Introduction. Series P100. Encapsulated Pressure Control. Auto-reset Standard Duty and Heavy Duty. Manual reset Standard Duty. Feature and Benefits PSC9919 European Refrigeration Controls Catalogue Catalog Section 6 Product Bulletin P100 Series P100 Encapsulated Pressure Control. Auto-reset Standard Duty and Heavy Duty. Manual reset Standard Duty.

More information

MAx-305 & MAx-318 Series MAx-405 Through MAx-419 Series Two-Position Actuators

MAx-305 & MAx-318 Series MAx-405 Through MAx-419 Series Two-Position Actuators MAx-305 & MAx-38 Series MAx-405 Through MAx-49 Series Two-Position Actuators General Instructions Application For two-position operation of dampers, valves, and other equipment which require the return

More information

Model 5000 Level Controller

Model 5000 Level Controller Features Multiple Configurations The 5000 level controller is easily configured for either reverse or direct actions for both pneumatic and electric pilot options. The pneumatic pilot is available in snap

More information

2000 Series Geared Rotary Limit Switches

2000 Series Geared Rotary Limit Switches SUPERIOR DESIGN AND OPERATING FEATURES Quality parts make each Geared Rotary Limit Switch highly dependable. The limit switch s ½ input shaft drives a bronze gear which rotates the cam block. The cam block

More information

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH INSTALLATION AND OPERATION MANUAL PN 610-0006 Rev E WARNING CAUTION SPECIAL CONDITIONS FOR SAFE USE NOTE Manual No. 610-0006 Rev

More information

Pressure. Pressure. Mechanical. Press. Switches

Pressure. Pressure. Mechanical. Press. Switches Pressure Pressure Mechanical Press. Switches Contents Mechanical Pressure Switches 4 Introduction 4 Metal Diaphragm 6 Bourdon Tube 7 Compact 8 Diaphragm Seal Piston Summary Mechanical Pressure Switches

More information

Adjustable Dead Band Pressure Switches

Adjustable Dead Band Pressure Switches The adjustable dead band pressure switch should be used when there is a requirement for an adjustable and wide dead band between the increasing and decreasing set points. Function Alarm: Hi Lo Control:

More information

DWYER INSTRUMENTS, INC. Phone: 219/ P.O. BOX 373 MICHIGAN CITY, IN 46361, U.S.A. Fax: 219/

DWYER INSTRUMENTS, INC. Phone: 219/ P.O. BOX 373 MICHIGAN CITY, IN 46361, U.S.A. Fax: 219/ Series 43000 Capsu-Photohelic Pressure Switch/Gage Specifications - Installation and Operating Instructions Bulletin B-34 Ø4-3/4 [120.65] 3-7/8 SQ [98.43] 3/4 CONDUIT 4-3/8 [111.13] HOUSING REMOVAL 3-1/16

More information

GO Switch Leverless Limit Switches 02 Reliable, Durable Position Sensing GO Switch leverless limit switches provide reliable, durable position sensing

GO Switch Leverless Limit Switches 02 Reliable, Durable Position Sensing GO Switch leverless limit switches provide reliable, durable position sensing GO Switch Leverless Limit Switches 02 Reliable, Durable Position Sensing GO Switch leverless limit switches provide reliable, durable position sensing in the most demanding plant conditions. Unlike mechanical

More information

% # ) Air and Inert Gas Intrinsically Safe Valves 2/2 3/2 4/2 5/2 5/3 SERIES. Brass, Aluminum, or Stainless Steel Bodies 1/4" to 1" NPT

% # ) Air and Inert Gas Intrinsically Safe Valves 2/2 3/2 4/2 5/2 5/3 SERIES. Brass, Aluminum, or Stainless Steel Bodies 1/4 to 1 NPT 4 Air and Inert Gas Intrinsically Safe Valves Brass, Aluminum, or Stainless Steel Bodies /4" to " NPT / 3/ 4/ 5/ 5/3 Features Intrinsically safe solenoid enclosures to provide corrosion resistance in harsh

More information

Temperature Switches. General Instructions

Temperature Switches. General Instructions This instruction provides information for mounting, electrical connection, process connection, and calibration of SOR Temperature Switches. The SOR Inc. Temperature Switch consists of a pressure switch

More information

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 123

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 123 BULLETIN NO. 123/11 (SUPERSEDES BULLETIN NO. 123/03) Piston Type Differential Pressure Gauges Switches & Transmitters A low cost differential pressure gauge for use in measuring the pressure drop across

More information

Adjustable Dead Band Pressure Switches

Adjustable Dead Band Pressure Switches Form 281 The adjustable dead band pressure switch should be used when there is a requirement for an adjustable and wide dead band between the increasing and decreasing set points. Function Alarm: Hi Lo

More information

Electropneumatic Timing Relays Series 7000 Industrial

Electropneumatic Timing Relays Series 7000 Industrial DESIGN FEATURES Available in On-Delay, True Off-Delay, and On/Off-Delay. Timing from 0.1 seconds to 60 minutes, fully calibrated in linear increments. Oversize time-calibrated adjustment knobs, serrated

More information

M-200X. Explosion Proof Adjustable Flow Switch with Right Angle Flow. Key Features. Description. Operating Principle. Applications

M-200X. Explosion Proof Adjustable Flow Switch with Right Angle Flow. Key Features. Description. Operating Principle. Applications Explosion Proof Adjustable Flow Switch with Right Angle Flow Key Features Field adjustable Infinite flow range Extremely accurate and sensitive Low pressure drop UL recognized for hazardous location ATEX

More information

Pressure Controls Product Overview

Pressure Controls Product Overview Bulletin Product Overview NEMA Bulletin Style A (Internal Bellows) Description Style C (External Bellows) Air Compressors Compressed Air Monitor Systems Liquid Level Control Typical Applications Vacuum

More information

MA-5200 Series MA-5300 Series

MA-5200 Series MA-5300 Series MA-5200 Series MA-5300 Series Two-Position Actuators General Instructions Application The MA-5200 series and MA-5300 series actuators are used for two-position control of valves and dampers which require

More information

Dual Hi-Lo Pressure Switches

Dual Hi-Lo Pressure Switches Dual Hi-Lo pressure switches are rugged, field-mounted instruments. The pressure sensing assemblies are conventional Static O Ring type. The main difference is that two sensing assemblies share a common

More information

Features and benefits. Normally open, normally closed contact logic

Features and benefits. Normally open, normally closed contact logic Pressure Switches Reliable pressure control by means of on / off electrical switch Normally open, normally closed contact logic Commercial and residential air conditioning systems The reliable and durable

More information

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures Mercmaster Series Luminaires LIGHTING: ENCLOSED AND GASKETED AREA /INDUCTION Applications Enclosed and gasketed fixtures suitable for use in: Marine and wet locations A wide range of industrial, chemical

More information

Environment-Sealed Basic Switches

Environment-Sealed Basic Switches HoneywellSensing and Control 1-800-537-6945 USA 1-815-235-6847International 1-416-293-8111Canada 13 Environment-Sealed Basic Switches GENERAL INFORMATION SE and XE switches are the smallest environment-sealed

More information

TEMPERATURE REGULATORS W91/W94 Series

TEMPERATURE REGULATORS W91/W94 Series Self-Operated Temperature Regulators Watson McDaniel reserves the right to change the designs and/or materials of its products without notice. 2010 Watson McDaniel Company Self-Operating Design Indicating

More information

M-100 Adjustable flow switch with right-angle flow

M-100 Adjustable flow switch with right-angle flow M-100 Adjustable flow switch with right-angle flow Operating Instructions and Quick Start Guide Table of Contents Introduction 03 Operation 03 Storage and Handling 03 Installation Instruction 03 Specification

More information

Model 5000 Level Controller

Model 5000 Level Controller Features Multiple Configurations The 5000 level controller is easily configured for either reverse or direct actions for both pneumatic and electric pilot options. The pneumatic pilot is available in snap

More information

W91/W94 Series TEMPERATURE REGULATORS. Self-Operated Temperature Regulators. Design & Operation W91 Non-Indicating W94 Dial Thermometer

W91/W94 Series TEMPERATURE REGULATORS. Self-Operated Temperature Regulators. Design & Operation W91 Non-Indicating W94 Dial Thermometer Design & Operation W91 Non-Indicating W94 Dial Thermometer Watson McDaniel reserves the right to change the designs and/or materials of its products without notice. 2010 Watson McDaniel Company CAPILLARY

More information

MS Application. Features. Proportional Valve Actuator General Instructions

MS Application. Features. Proportional Valve Actuator General Instructions Proportional Valve Actuator Application The Proportional Valve Actuator is a non-spring return actuator used with proportional to 10 Vdc or 4 to 0 ma controllers and standard 1/" to 1-1/4" two-way and

More information

CIRCULATION HEATERS SPECIFICATIONS DESCRIPTION FEATURES CH & CHP SERIES HEAT EXCHANGE AND TRANSFER, INC. 6 to 480 kw and higher. Flanged construction

CIRCULATION HEATERS SPECIFICATIONS DESCRIPTION FEATURES CH & CHP SERIES HEAT EXCHANGE AND TRANSFER, INC. 6 to 480 kw and higher. Flanged construction SPECIFICATIONS 6 to 480 kw and higher CIRCULATION HEATERS CH & CHP SERIES Flanged construction 208 volt through 575 volt, 3 phase 5 to 40 watts/in 2 and higher NEMA 4/12 Terminal housing DESCRIPTION Type

More information

Type Type 1001 Transducers. I/P & E/P Transducers

Type Type 1001 Transducers. I/P & E/P Transducers Type 1001 I/P & E/P Description The Type 1001 is a patented family of electropneumatic instruments that is used to reduce a supply pressure to a regulated output pressure which is directly proportional

More information

the Interactive Catalog

the Interactive Catalog Interactive Catalog Supplements Catalog PDFs If you need detailed product information, or help choosing the right product for your application, see our Interactive Catalog Use the Interactive Catalog to

More information

B Temperature Switches

B Temperature Switches B Temperature Switches General Instructions These instructions provide information for installation n and field calibration of B Temperature Switches. Process temperature changes cause proportional vapor

More information

Pressure Instrument Testing Equipment

Pressure Instrument Testing Equipment Pressure Instrument Testing Equipment BULLETIN TE-1 A Halliburton Company A Durable, Portable Primary Standard Model 1305D Deadweight Tester The Ashcroft 1305D Deadweight Tester is an affordable, portable

More information

CP-8301-xxx Series. Application. Features. Applicable Literature. 1 to 15 Vdc Input Electronic Actuator Drive General Instructions

CP-8301-xxx Series. Application. Features. Applicable Literature. 1 to 15 Vdc Input Electronic Actuator Drive General Instructions CP-80-xxx Series to 5 Vdc Input Electronic General Instructions Application The CP-80-xxx Series electronic actuator drive is designed to process a variable to 5 Vdc signal from a controller to provide

More information

M-60X. Explosion Proof Flowswitch with In-line Flow. Description. Key Features. Operating Principle. Applications. Custom Version Available

M-60X. Explosion Proof Flowswitch with In-line Flow. Description. Key Features. Operating Principle. Applications. Custom Version Available Explosion Proof Flowswitch with In-line Flow Key Features Well suitable for corrosive and noncorrosive liquids or gases UL recognized for hazardous location ATEX certified for intrinsic safety and encapsulation

More information

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 124

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 124 BULLETIN NO. 124/12 (SUPERSEDES BULLETIN NO. 124/11) Mid-West Instrument Piston Type Differential Pressure Gauges Switches & Transmitters A low cost differential pressure gauge for use in measuring the

More information

M-50/55 Series. Fixed setting flow switch with in-line flow

M-50/55 Series. Fixed setting flow switch with in-line flow M-50/55 Series Fixed setting flow switch with in-line flow Features Very accurate custom flow settings For corrosive and non-corrosive liquids or gases All-Teflon switch available Senses increasing or

More information

Integrated Control modules

Integrated Control modules .604.0 - Rev: 6, Page of Integrated Control modules QC4, QC42 and QC43 Features: - Basic actuator functions for: - Spring return applications, or - Double acting applications or, - Double acting Fail in

More information

CP-9301 CP Application. Features. Applicable Literature. Electronic Actuator Drives General Instructions

CP-9301 CP Application. Features. Applicable Literature. Electronic Actuator Drives General Instructions CP-90 CP-90 Electronic Drives General Instructions Application The CP-90 and CP-90 electronic actuator drives process a variable input signal from a controller to provide proportional control of an electric

More information

MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES,

MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES, NEO-DYN MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES, ENCLOSURE 6N FOR EXPLOSIVE ATMOSPHERES INSTALLATION AND OPERATION MANUAL PN 610-0014 E Manual No. 610-0014 Rev E Neo-Dyn 28150 Industry Drive

More information

10 S e r i e s PRESSURE SWITCH. features

10 S e r i e s PRESSURE SWITCH. features 10 S er i es 10 S e r i e s PRESSURE SWITCH features Tamper-Resistant Field Adjustment Adjustable Ranges from 4 to 7500 PSI (0,3 to 517,1 Bar) Choice of 7 Electrical Terminations 1-1/4" Diameter Height

More information

Installation and Service Instructions for EX Series Explosion-proof Switches

Installation and Service Instructions for EX Series Explosion-proof Switches Installation and Service Instructions for EX Series Explosion-proof Switches ISSUE 4 50009662 WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application

More information

FF Pressure Switch. Diaphragm and piston switches

FF Pressure Switch. Diaphragm and piston switches FF Pressure Switch FF Pressure Switch Diaphragm and piston switches Product informations The new FF pressure switch design is based on 40 years of know-how and is an example for consequent quality oriented

More information

the Interactive Catalog

the Interactive Catalog Interactive Catalog Supplements Catalog PDFs If you need detailed product information, or help choosing the right product for your application, see our Interactive Catalog Use the Interactive Catalog to

More information

Control Without Compromise. Suitable for use in hot, cold, wet, dirty, abusive, corrosive, and explosive environments

Control Without Compromise. Suitable for use in hot, cold, wet, dirty, abusive, corrosive, and explosive environments leverless limit switches Proximity Sensors for Harsh Environments and Tough Applications Suitable for use in hot, cold, wet, dirty, abusive, corrosive, and explosive environments Certified for use in all

More information

Remote Temperature Controllers. Quick Selection Guide

Remote Temperature Controllers. Quick Selection Guide Remote Temperature Controllers Quick Selection Guide A Complete Selection For A Wide Range Of Applications Electronic Standalone Controllers T775 Provide on/off, modulating, or reset control in applications

More information

Industrial Pressure Transmitters

Industrial Pressure Transmitters Industrial Pressure Transmitters Type S-10, S-11 Applications Hydraulics and pneumatics Test equipment Pump and compressor control Liquid level measurement Special Features Standard ranges available from

More information

Our new range of electromechanical pressure switches with fixed setting are compact, light and easy to install.

Our new range of electromechanical pressure switches with fixed setting are compact, light and easy to install. New Snap Disk Fixed setting pressure switches Compatible Refrigerants R22, R134a, R401, R402, R404, R407C, R410 and their lubricating oils, CO2 and R290 Our new range of electromechanical pressure switches

More information

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D Cl. I, Div. and 2, Groups B, C, D Cl. II, Div., Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 3, 4, 4*,, Ex d IIB + H2 T, IP Explosionproof Dust-Ignitionproof Raintight Wet Locations Applications:

More information

Series P100AP and P100CP Encapsulated Pressure Control. Auto-reset Standard Duty. Feature and Benefits

Series P100AP and P100CP Encapsulated Pressure Control. Auto-reset Standard Duty. Feature and Benefits PSC9919 European Refrigeration Controls Catalogue Catalog Section 6 Product Bulletin P100 Series P100AP and P100CP Encapsulated Pressure Control. Auto-reset Standard Duty Introduction The P100 Series are

More information

U.S. GAUGE PMT PRODUCTS 820 PENNSYLVANIA BLVD., FEASTERVILLE, PENNSYLVANIA U.S.A. TEL: (215) FAX: (215)

U.S. GAUGE PMT PRODUCTS 820 PENNSYLVANIA BLVD., FEASTERVILLE, PENNSYLVANIA U.S.A. TEL: (215) FAX: (215) U.S. GAUGE PMT PRODUCTS 820 PENNSYLVANIA BLVD., FEASTERVILLE, PENNSYLVANIA 19053 U.S.A. TEL: (215) 355-6900 FAX: (215) 354-1801 www.ametekusg.com 2009, by AMETEK, Inc. All rights reserved. Printed in the

More information