1 ZX-Family Gas-insulated medium voltage switchgear

2 Durable and reliable Minimum overall costs Safety first ZX offers maximum economy Sealed gas compartments The compact design of the panels reduces the space required and therefore the size of the station. Freedom from maintenance is achieved by constant conditions in the high voltage compartments in conjunction with the selection of suitable materials. s a rule, therefore, isolation of the switchgear to perform maintenance work is not required. The panels are designed for an expected service life of over 0 years. Thanks to the plug-in technology applied in the areas of the busbars, cables and secondary systems, extremely short installation times are possible. No gas work is required as a rule at site. The filling with SF ensures permanently constant ambient conditions. Nevertheless, components such as switching devices or bushings may have to be repaired or possibly replaced. Topping up in the event of a loss of insulating gas can be performed without interrupting operation, and possible shutdowns can therefore be planned. The SF is monitored with temperature compensation, by density sensors with a self-monitoring function. s a result of the closed circuit design, wire breakages and defective plug or terminal connections are signalled as faults. ZX0 elements at a glance Multifunctional protection and control unit Measuring sockets for capacitive voltage indicator system Three position disconnector Vacuum circuit-breaker Cable connector at outer cone Ring-type current transformer Isolatable voltage transformer feeder Pressure relief disk Busbars Plug-in voltage transformer busbar Circuit-breaker panel 0 ZX0. elements at a glance Removable low voltage compartment with protection and control unit Three position disconnector Local controls in front of mechanism bay Gas density sensor and filling valve Vacuum circuit-breaker Measuring sockets for capacitive voltage indicator system Cable connector at outer cone Ring-type current transformer Isolatable voltage transformer feeder Pressure relief disk Solid-insulated busbars Plug-in voltage transformer busbar Circuit-breaker panel 000 ZX ensures maximum operator safety ZX0. ZX. Compact system for distribution applications in block design. Installation against a wall or free-standing in the room. Both local manual operation and remote control are facilitated. Together with vacuum circuit-breakers, there are switch-disconnectors with and without fuses. Metal-enclosed single busbar system for transformer and distribution switchgear in individual panel design. Installation against a wall or free-standing in the room. ll systems have mechanical controls for local operation, but can also be remote controlled with optional motorized mechanisms for the three position disconnectors. Together with vacuum circuit-breakers, ZX0. also offers three position switch disconnector and fuse combinations. Metal partitioned single busbar system for transformer and distribution substations with raised cable terminations for ultra-simple cable installation from the rear. ll switching devices can be remote controlled and optionally mechanically interlocked. Main components of ZX. Plug-in voltage transformer feeder Isolating system for voltage transformer Gas density sensor and filling valve Multifunctional protection and control unit Vacuum circuit-breaker Three position disconnector Busbars Pressure relief disk Pressure relief duct Inner cone cable connector Cable socket Measuring sockets for capacitive voltage indicator system Test socket Current transformer or combined current and voltage sensor Plasma diverter Feeder 000 ZX0 ll live components are enclosed to prevent accidental contact. s the high voltage compartments are independent of external influences (degree of protection IP), the probability of a fault during operation is extremely low. s evidenced by arc fault testing, our switchgear systems are notable for maximum operator safety. further enhancement can be achieved by providing pressure relief to outside the switchgear room. Special Ratings 0. / 0/ / 0/ / 0/ 0/0 / 0 0 Rated current of busbars Rated current of feeder with CB 0 0 Rated current of tee-off with circuit-breaker 0 0 Rated current of feeder Rated current of feeder with load break switch 0 0 Rated current of tee-off with switch-disconnector and fuses k.. k.. for circuit-breaker k Rated short-time current s k Rated short-time current s k Rated short-time current s for circuit-breaker k Internal rc Classification according to VDE 0 part 00 DS ZX-Family GB.indd Wall installation: IC FL k s ; Free-standing installation IC FLR k s Internal rc Classification Wall installation: IC FL. k s ; Free-standing installation IC FLR. k s Internal rc Classification with plasma diverter IC FL. k s ; with plasma absorber and duct IC FLR. k s according to VDE 0 part 00 according to VDE 0 part :

3 Durable and reliable Minimum overall costs Safety first ZX offers maximum economy Sealed gas compartments The compact design of the panels reduces the space required and therefore the size of the station. Freedom from maintenance is achieved by constant conditions in the high voltage compartments in conjunction with the selection of suitable materials. s a rule, therefore, isolation of the switchgear to perform maintenance work is not required. The panels are designed for an expected service life of over 0 years. Thanks to the plug-in technology applied in the areas of the busbars, cables and secondary systems, extremely short installation times are possible. No gas work is required as a rule at site. The filling with SF ensures permanently constant ambient conditions. Nevertheless, components such as switching devices or bushings may have to be repaired or possibly replaced. Topping up in the event of a loss of insulating gas can be performed without interrupting operation, and possible shutdowns can therefore be planned. The SF is monitored with temperature compensation, by density sensors with a self-monitoring function. s a result of the closed circuit design, wire breakages and defective plug or terminal connections are signalled as faults. ZX0 elements at a glance Multifunctional protection and control unit Measuring sockets for capacitive voltage indicator system Three position disconnector Vacuum circuit-breaker Cable connector at outer cone Ring-type current transformer Isolatable voltage transformer feeder Pressure relief disk Busbars Plug-in voltage transformer busbar Circuit-breaker panel 0 ZX0. elements at a glance Removable low voltage compartment with protection and control unit Three position disconnector Local controls in front of mechanism bay Gas density sensor and filling valve Vacuum circuit-breaker Measuring sockets for capacitive voltage indicator system Cable connector at outer cone Ring-type current transformer Isolatable voltage transformer feeder Pressure relief disk Solid-insulated busbars Plug-in voltage transformer busbar Circuit-breaker panel 000 ZX ensures maximum operator safety ZX0. ZX. Compact system for distribution applications in block design. Installation against a wall or free-standing in the room. Both local manual operation and remote control are facilitated. Together with vacuum circuit-breakers, there are switch-disconnectors with and without fuses. Metal-enclosed single busbar system for transformer and distribution switchgear in individual panel design. Installation against a wall or free-standing in the room. ll systems have mechanical controls for local operation, but can also be remote controlled with optional motorized mechanisms for the three position disconnectors. Together with vacuum circuit-breakers, ZX0. also offers three position switch disconnector and fuse combinations. Metal partitioned single busbar system for transformer and distribution substations with raised cable terminations for ultra-simple cable installation from the rear. ll switching devices can be remote controlled and optionally mechanically interlocked. Main components of ZX. Plug-in voltage transformer feeder Isolating system for voltage transformer Gas density sensor and filling valve Multifunctional protection and control unit Vacuum circuit-breaker Three position disconnector Busbars Pressure relief disk Pressure relief duct Inner cone cable connector Cable socket Measuring sockets for capacitive voltage indicator system Test socket Current transformer or combined current and voltage sensor Plasma diverter Feeder 000 ZX0 ll live components are enclosed to prevent accidental contact. s the high voltage compartments are independent of external influences (degree of protection IP), the probability of a fault during operation is extremely low. s evidenced by arc fault testing, our switchgear systems are notable for maximum operator safety. further enhancement can be achieved by providing pressure relief to outside the switchgear room. Special Ratings 0. / 0/ / 0/ / 0/ 0/0 / 0 0 Rated current of busbars Rated current of feeder with CB 0 0 Rated current of tee-off with circuit-breaker 0 0 Rated current of feeder Rated current of feeder with load break switch 0 0 Rated current of tee-off with switch-disconnector and fuses k.. k.. for circuit-breaker k Rated short-time current s k Rated short-time current s k Rated short-time current s for circuit-breaker k Internal rc Classification according to VDE 0 part 00 DS ZX-Family GB.indd Wall installation: IC FL k s ; Free-standing installation IC FLR k s Internal rc Classification Wall installation: IC FL. k s ; Free-standing installation IC FLR. k s Internal rc Classification with plasma diverter IC FL. k s ; with plasma absorber and duct IC FLR. k s according to VDE 0 part 00 according to VDE 0 part :

4 Durable and reliable Minimum overall costs Safety first ZX offers maximum economy Sealed gas compartments The compact design of the panels reduces the space required and therefore the size of the station. Freedom from maintenance is achieved by constant conditions in the high voltage compartments in conjunction with the selection of suitable materials. s a rule, therefore, isolation of the switchgear to perform maintenance work is not required. The panels are designed for an expected service life of over 0 years. Thanks to the plug-in technology applied in the areas of the busbars, cables and secondary systems, extremely short installation times are possible. No gas work is required as a rule at site. The filling with SF ensures permanently constant ambient conditions. Nevertheless, components such as switching devices or bushings may have to be repaired or possibly replaced. Topping up in the event of a loss of insulating gas can be performed without interrupting operation, and possible shutdowns can therefore be planned. The SF is monitored with temperature compensation, by density sensors with a self-monitoring function. s a result of the closed circuit design, wire breakages and defective plug or terminal connections are signalled as faults. ZX0 elements at a glance Multifunctional protection and control unit Measuring sockets for capacitive voltage indicator system Three position disconnector Vacuum circuit-breaker Cable connector at outer cone Ring-type current transformer Isolatable voltage transformer feeder Pressure relief disk Busbars Plug-in voltage transformer busbar Circuit-breaker panel 0 ZX0. elements at a glance Removable low voltage compartment with protection and control unit Three position disconnector Local controls in front of mechanism bay Gas density sensor and filling valve Vacuum circuit-breaker Measuring sockets for capacitive voltage indicator system Cable connector at outer cone Ring-type current transformer Isolatable voltage transformer feeder Pressure relief disk Solid-insulated busbars Plug-in voltage transformer busbar Circuit-breaker panel 000 ZX ensures maximum operator safety ZX0. ZX. Compact system for distribution applications in block design. Installation against a wall or free-standing in the room. Both local manual operation and remote control are facilitated. Together with vacuum circuit-breakers, there are switch-disconnectors with and without fuses. Metal-enclosed single busbar system for transformer and distribution switchgear in individual panel design. Installation against a wall or free-standing in the room. ll systems have mechanical controls for local operation, but can also be remote controlled with optional motorized mechanisms for the three position disconnectors. Together with vacuum circuit-breakers, ZX0. also offers three position switch disconnector and fuse combinations. Metal partitioned single busbar system for transformer and distribution substations with raised cable terminations for ultra-simple cable installation from the rear. ll switching devices can be remote controlled and optionally mechanically interlocked. Main components of ZX. Plug-in voltage transformer feeder Isolating system for voltage transformer Gas density sensor and filling valve Multifunctional protection and control unit Vacuum circuit-breaker Three position disconnector Busbars Pressure relief disk Pressure relief duct Inner cone cable connector Cable socket Measuring sockets for capacitive voltage indicator system Test socket Current transformer or combined current and voltage sensor Plasma diverter Feeder 000 ZX0 ll live components are enclosed to prevent accidental contact. s the high voltage compartments are independent of external influences (degree of protection IP), the probability of a fault during operation is extremely low. s evidenced by arc fault testing, our switchgear systems are notable for maximum operator safety. further enhancement can be achieved by providing pressure relief to outside the switchgear room. Special Ratings 0. / 0/ / 0/ / 0/ 0/0 / 0 0 Rated current of busbars Rated current of feeder with CB 0 0 Rated current of tee-off with circuit-breaker 0 0 Rated current of feeder Rated current of feeder with load break switch 0 0 Rated current of tee-off with switch-disconnector and fuses k.. k.. for circuit-breaker k Rated short-time current s k Rated short-time current s k Rated short-time current s for circuit-breaker k Internal rc Classification according to VDE 0 part 00 DS ZX-Family GB.indd Wall installation: IC FL k s ; Free-standing installation IC FLR k s Internal rc Classification Wall installation: IC FL. k s ; Free-standing installation IC FLR. k s Internal rc Classification with plasma diverter IC FL. k s ; with plasma absorber and duct IC FLR. k s according to VDE 0 part 00 according to VDE 0 part :

5 Maximum availability Double busbar panel for 000 Easy, simple and fast The busbar technology permits simple and therefore safe assembly. In spite of the extremely low failure probability of the ZX switchgear systems, replacement of components in the gas compartments and therefore a rapid return to service after repairs is possible. In gas-insulated switchgear, earthing of switchgear sections is performed by a high quality vacuum circuit-breaker. The circuit-breaker can close onto a short-circuit significantly more frequently and reliably than a positively making earthing switch. ZX key elements Three position disconnector Multifunctional protection and control unit Gas density sensor and filling valve Vacuum circuit-breaker Cable socket Inner cone cable connector Plug-in voltage transformer feeder Pressure relief disk Current transformer or combined current and voltage sensor Pressure relief duct Measuring sockets for capacitive voltage indicator system Busbars Plug-in voltage transformer busbar ZX Metal partitioned single or double busbar system for all applications even with the highest parameters. Cables accessible from the rear. ll switching devices can be remote controlled and optionally mechanically interlocked. Both combined protection and control devices and pure protection devices are used. Special Ratings / 0/ 0/0 /00 ) Rated current of feeder k Rated short-time current s k Internal rc Classification IC FLR 0 k s according to VDE 0 part 00 ) Single busbar systems up to 000 on request

6 Contact Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. BB G does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. ny reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of BB G. DEBB EN (.-00-MC) Your sales contact: More product information: Copyright 0 BB ll rights reserved BB G Calor Emag Medium Voltage Products Oberhausener Strasse 0 Ratingen, Germany Phone: +(0) 0/-0 Fax: +(0) 0/- powertech@de.abb.com BB G Calor Emag Medium Voltage Products Petzower Strasse Werder (Havel) OT Glindow, Germany Phone: +(0) 0/-0 Fax: +(0) 0/- powertech@de.abb.com

ZX-Family Gas-insulated medium voltage switchgear

ZX-Family Gas-insulated medium voltage switchgear ZX-Family Gas-insulated medium voltage switchgear Minimum overall costs ZX offers maximum economy The compact design of the panels reduces the space required and therefore the size of the station. Freedom

More information

ZX2 Gas-insulated medium voltage switchgear

ZX2 Gas-insulated medium voltage switchgear Gas-insulated medium voltage switchgear Double busbar 13 8 10 12 11 10 9 8 7 2 1 3 4 5 6 2 Versatile Partitioned single or double busbar system for all applications even with the most demanding parameters

More information

voltage switchgear ZX ABB ZX Family 1

voltage switchgear ZX ABB ZX Family 1 Gas-insulated medium voltage switchgear ZX ABB ZX Family 1 ZX family general presentation Agenda Medium Voltage Switchgear Definition and application ABB Calor Emag in Ratingen Location, experience and

More information

ZX2.2 Gas-insulated medium voltage switchgear

ZX2.2 Gas-insulated medium voltage switchgear ZX2.2 Gas-insulated medium voltage switchgear 2 Brochure ZX2.2 Power engineering from ABB Solutions for the future As a technology group with global operations, ABB supplies the solutions of the future

More information

ZX1.2. Gas-insulated medium voltage switchgear

ZX1.2. Gas-insulated medium voltage switchgear ZX1.2 Gas-insulated medium voltage switchgear Power engineering from ABB. Solutions for the future. A strong family for all seasons. Equipped to master all requirements, the members of the ZX family provide

More information

ZX1.5-R. Gas-insulated medium voltage for railway application DISTRIBUTION SOLUTIONS. Gas-insulated medium voltage for railway application ZX1.

ZX1.5-R. Gas-insulated medium voltage for railway application DISTRIBUTION SOLUTIONS. Gas-insulated medium voltage for railway application ZX1. DISTRIBUTION SOLUTIONS ZX1.5-R Gas-insulated medium voltage for railway application Safety and reliability 20% footprint saving Easy operation Complete solution ZX1.5-R Gas-insulated medium voltage for

More information

EMPAC Metal enclosed capacitor bank for wind applications

EMPAC Metal enclosed capacitor bank for wind applications EMPAC Metal enclosed capacitor bank for wind applications Introduction The EMPAC is a Metal Enclosed Capacitor Bank suitable for voltages between 1 kv and 36 kv for reactive compensation in MV networks

More information

MEDIUM VOLTAGE PRODUCTS. Fault Current Limiters I S. -limiter and FC-Protector The worldʼs fastest switching devices

MEDIUM VOLTAGE PRODUCTS. Fault Current Limiters I S. -limiter and FC-Protector The worldʼs fastest switching devices MEDIUM VOLTAGE PRODUCTS The worldʼs fastest switching devices 2 FAULT CURRENT LIMITERS THE WORLDʼ S FASTETST SWITCHING DEVICES The worldʼs fastest switching devices ABBʼs fault current limiters disconnect

More information

NXPLUS C Single busbar. Maintenance-free for lifetime

NXPLUS C Single busbar. Maintenance-free for lifetime NXPLUS C Single busbar Maintenance-free for lifetime Energy Distribution Welcome! Page 2 Content Overview Technical data Typicals Panel design Circuit-Breaker panel Busbar Operation Metering Low-voltage

More information

Gas Insulated Metal-clad Switchgear, HMGS!

Gas Insulated Metal-clad Switchgear, HMGS! Medium Voltage HMGS-G10 HYUNDAI Medium Voltage Gas Insulated Metal-clad Switchgear, HMGS! SF6 Gas Insulated Metal-clad Switchgear is an integrated assembly of vacuum circuit breaker, 3-position switch,

More information

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards Medium Voltage Switchgear Primary Distribution CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka General description Presentation Ormazabal s CPG System includes the CPG.1

More information

Medium voltage products UniSec DY800 New 24 kv air-insulated medium voltage switchgear to e-distribuzione specifications

Medium voltage products UniSec DY800 New 24 kv air-insulated medium voltage switchgear to e-distribuzione specifications Medium voltage products UniSec Y800 New 24 kv air-insulated medium voltage switchgear to e-istribuzione specifications UniSec Y800 ubicles available Unit e-istribuzione specifications (Ed. 4) UniSec IS/1

More information

Brochure. Modular Systems wind portfolio Power Collection and Grid Connection products

Brochure. Modular Systems wind portfolio Power Collection and Grid Connection products Brochure Modular Systems wind portfolio Power Collection and Grid Connection products Wind portfolio Background ABB is one of the few suppliers that has been deeply involved in wind power segment development,

More information

General. Main electric circuits Fuses compartment Operating mechanisms Cables connection compartment

General. Main electric circuits Fuses compartment Operating mechanisms Cables connection compartment General The switchgear must be suitable for 36 kv rated voltage and specifically conceived for the secondary distribution substations in M.V. with either ring or radial type networks. The switchgear must

More information

Vacuum Circuit Breaker

Vacuum Circuit Breaker Vacuum Circuit Breaker 12/24kV VECTOR series Vacuum Circuit Breaker VMS series Metal-clad Switchgear Medium Voltage Systems 003 FM 73638 12/24kV VECTOR VCB Features of the VECTOR Vacuum Circuit Breaker:

More information

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable www.siemens.com/medium-voltage-switchgear Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable Medium-Voltage Switchgear Catalog HA 41.43 2012 Answers for infrastructure and cities. Neue Bilder

More information

Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A

Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A DISTRIBUTION SOLUTIONS Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A Superior performance versus standard fuses ensuring up to 40% faster protection in case of low

More information

Product brochure Generator circuit-breaker HVS-63S System type GCB with innovative built-in monitoring

Product brochure Generator circuit-breaker HVS-63S System type GCB with innovative built-in monitoring Product brochure Generator circuit-breaker HVS-63S System type GCB with innovative built-in monitoring ABB is a leader in power and automation technologies that enable utility and industry customers to

More information

8DJ. Maintenance-free for lifetime

8DJ. Maintenance-free for lifetime 8DJ Maintenance-free for lifetime Energy Distribution Welcome! Page 2 October 1 st 2008 8DJ Main Applications for Medium-Voltage Switchgear Power generation Power stations G Power transmission High and

More information

Fuse-links type CEF-VT Rated voltages 3/7.2 kv - 10/24 kv Rated current 0.5 A 6.3 A

Fuse-links type CEF-VT Rated voltages 3/7.2 kv - 10/24 kv Rated current 0.5 A 6.3 A DISTRIBUTION SOLUTIONS Fuse-links type CEF-VT Rated voltages 3/7.2 kv - 10/24 kv Rated current 0.5 A 6.3 A Efficient protection of voltage transformer circuits Extending the lifetime of installed electrical

More information

GHA. Gas-Insulated Switchgear. Gas-Insulated Switchgear. Switchgear extension and replacement of a panel

GHA. Gas-Insulated Switchgear. Gas-Insulated Switchgear. Switchgear extension and replacement of a panel Gas-Insulated Switchgear GHA Gas-Insulated Switchgear Switchgear extension and replacement of a panel During this work, essential parts of the switchgear remain in operation No. AGS 535 066-01 Edition

More information

MESG 12 / 17.5 / 24 / 36 KV

MESG 12 / 17.5 / 24 / 36 KV MESG 12 / 17.5 / 24 / 36 KV Medium Voltage Air Insulated Metal Enclosed Switchgear up to 36 kv- up to 1250 A - up to 25 ka for 1 sec. with SF6 or vacuum circuit breakers. 750 METAL ENCLOSED 1 1 ) GENERAL

More information

TECHNICAL CATALOGUE TK 502/20 EN. ZX2 Gas-insulated medium voltage switchgear

TECHNICAL CATALOGUE TK 502/20 EN. ZX2 Gas-insulated medium voltage switchgear TECHNICAL CATALOGUE TK 502/20 EN ZX2 Gas-insulated medium voltage switchgear Contents Page 1 Introduction 5 2 Applications 6 3 Characteristics 7 4 Your benefit 8 5 Technical data 9 5.1 Technical data of

More information

Manual motor starter magnetic only MO325

Manual motor starter magnetic only MO325 Data sheet Manual motor starter magnetic only MO325 Manual motor starters magnetic only are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF

More information

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv SF6 circuit breaker EDT with integrated current transformer ABB is a world leader in live tank circuit breaker

More information

Catalog HA Edition up to 24 kv, Air-Insulated, Extendable. Medium-Voltage Switchgear. siemens.com/simosec

Catalog HA Edition up to 24 kv, Air-Insulated, Extendable. Medium-Voltage Switchgear. siemens.com/simosec Catalog HA 41.43 Edition 2018 Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable Medium-Voltage Switchgear siemens.com/simosec Application Typical uses R-HA41-135.tif R-HA40-112.tif R-HA41-115.tif

More information

Modular Standardized Electrical and Control Solutions for Fast Track Projects

Modular Standardized Electrical and Control Solutions for Fast Track Projects Modular Standardized Electrical and Control Solutions for Supporting fast track projects ABB is the leading supplier of electrical and control equipment for power plants. The company offers a comprehensive

More information

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable Medium-Voltage Switchgear Totally Integrated Power SIMOSEC Catalog HA 41.43 Edition Sept. 2014 Answers for infrastructure and cities. Neue

More information

Product Brochure. Gas-insulated Switchgear ELK-14 The modular system for GIS, 245 kv

Product Brochure. Gas-insulated Switchgear ELK-14 The modular system for GIS, 245 kv Product Brochure Gas-insulated Switchgear ELK-14 The modular system for GIS, 245 kv ABB switchgear systems provide maximum reliability Built on years of experience - ready to serve your future needs For

More information

SACE Emax 2/ML Low-voltage air circuit breakers for naval applications

SACE Emax 2/ML Low-voltage air circuit breakers for naval applications LOW VOLTAGE SACE Emax 2/ML Low-voltage air circuit breakers for naval applications 2 SACE EMAX 2/ML LOW-VOLTAGE AIR CIRCUIT BREAKERS FOR NAVAL APPLICATIONS SACE Emax 2/ML Robustness and reliability up

More information

Overview Overvoltage protection

Overview Overvoltage protection A P P L I C AT I O N N OT E 1.0 Overview Overvoltage protection The APPLICATION NOTES (AN) are intended to be used in conjunction with the APPLICATION GUIDELINES Overvoltage protection Metal-oxide surge

More information

Manual motor starter MS132

Manual motor starter MS132 Data sheet Manual motor starter MS132 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less

More information

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear Circuit-Breaker www.siemens.com/energy Switchgear Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear s Technology Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated

More information

Product Brochure. Generator Circuit-Breaker HVR-EBCB For hydro or pump storage power plant

Product Brochure. Generator Circuit-Breaker HVR-EBCB For hydro or pump storage power plant Product Brochure Generator Circuit-Breaker HVR-EBCB For hydro or pump storage power plant Introduction General The braking switch serves the purpose of electrical braking a machine in a hydro or pumped

More information

Manual motor starter MS116

Manual motor starter MS116 Data sheet Manual motor starter MS116 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less

More information

Manual motor starters Overview and benefits

Manual motor starters Overview and benefits Manual motor starters Overview and benefits ABB offers a complete standard motor-protection concept for the world market IEC motor branch protection UL type E/F Motor applications with fuseless protection

More information

When grids get smart ABB your partner for developing Smart Grids solutions

When grids get smart ABB your partner for developing Smart Grids solutions When grids get smart ABB your partner for developing Smart Grids solutions A transition from traditional to Smart Grids ABB`s commitment to Smart Grids The traditional power grid is based on centralized

More information

Semi-pantograph disconnector type DSSP, up to 300 kv Maximum reliability and minimal maintenance

Semi-pantograph disconnector type DSSP, up to 300 kv Maximum reliability and minimal maintenance Semi-pantograph disconnector type DSSP, up to 300 kv Maximum reliability and minimal maintenance Semi-pantograph disconnector type DSSP, up to 300 kv Maximum reliability and minimal maintenance 2 Semi-pantograph

More information

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv] BasisBlock MC 1 Standards and Regulations IEC 62271-200 ; VDE 0671-200 ; BS EN 62271-200 Technical Data MC1-12 MC1-24 Voltage Rated operating voltage [kv] 12 24 Rated power frequency withstand voltage

More information

SF 6 gas insulated RMU SafePlus 24 kv. ABB SafePlus 24 kv SF6 gas insulated RMU 1

SF 6 gas insulated RMU SafePlus 24 kv. ABB SafePlus 24 kv SF6 gas insulated RMU 1 SF 6 gas insulated RMU SafePlus 24 kv 25.03.2010 SafePlus 24 kv SF6 gas insulated RMU 1 Secondary distribution 400 kv Transmission substation Transformer 40-70 kv 130 kv Main Substation Secondary distribution

More information

Manual motor starter MS132

Manual motor starter MS132 Data sheet Manual motor starter MS132 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less

More information

Manual motor starter MS132

Manual motor starter MS132 Data sheet Manual motor starter MS132 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less

More information

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE Certificate Number FM35831 APPLICATION Typical Uses and Classification The MSGair switchgear is used in transformer and switching substations mainly

More information

Fixed-Mounted Circuit-Breaker Switchgear Type 8DA and 8DB up to 40.5 kv, Gas-Insulated

Fixed-Mounted Circuit-Breaker Switchgear Type 8DA and 8DB up to 40.5 kv, Gas-Insulated www.siemens.com/medium-voltage-switchgear Fixed-Mounted Circuit-Breaker Switchgear Type 8D and 8DB up to 0.5 kv, Gas-Insulated Medium-Voltage Switchgear Catalog H 35.11 201 nswers for infrastructure and

More information

Air-insulated switchgear UniGear type ZS1

Air-insulated switchgear UniGear type ZS1 Air-insulated switchgear UniGear type ZS1 ABB Power Technologies / 1-7074 D 12-03-2003 - Air-insulated switchgear UniGear type ZS1 ABB Power Technologies / 2-7075 D 1 2-03-2003 - Rated voltage kv 12 17.5

More information

Emergency-off application Manual motor starter MS116/MS132 Undervoltage release UA1

Emergency-off application Manual motor starter MS116/MS132 Undervoltage release UA1 pplication description EN Emergency-off application Manual motor starter MS116/MS132 Undervoltage release U1 The emergency-off application allows machine and job safety for nominal currents up to 32 all

More information

TriLine PowerModules Overview with Planing Examples

TriLine PowerModules Overview with Planing Examples 04 2012 TriLine PowerModules Overview with Planing Examples Catalog template for LSO with German prices The rates must be adjusted to country-specific from the LSO TriLine PowerModules Contents The new

More information

Power Transmission and Distribution. NXPLUS C double busbar. The economical solution when replacing old systems

Power Transmission and Distribution. NXPLUS C double busbar. The economical solution when replacing old systems Power Transmission and Distribution NXPLUS C double busbar The economical solution when replacing old systems The compact switchgear system NXPLUS C double busbar up to kv, up to 5 ka and up to 500A the

More information

BRIDGE-BOY Load limitation electronics with 1 or 3 set points

BRIDGE-BOY Load limitation electronics with 1 or 3 set points Change from one to two columns Data Sheet DS/BRIDGE-BOY-LCI-EN Rev. A BRIDGE-BOY Load limitation electronics with 1 or 3 set points Electronics with 1 or 3 set points designed, in combination with a load

More information

Fixed-Mounted Circuit-Breaker Switchgear Type 8DA and 8DB up to 40.5 kv, Gas-Insulated

Fixed-Mounted Circuit-Breaker Switchgear Type 8DA and 8DB up to 40.5 kv, Gas-Insulated Fixed-Mounted Circuit-Breaker Switchgear Type 8D and 8DB up to 0.5 kv, Gas-Insulated Medium-Voltage Switchgear Catalog H 35. 00 nswers for energy. R-H35-30.eps pplication Public power supply system R-H35-3.eps

More information

MEDIUM VOLTAGE PRODUCT. TJC 4 Indoor voltage transformers

MEDIUM VOLTAGE PRODUCT. TJC 4 Indoor voltage transformers MEDIUM VOLTAGE PRODUCT TJC 4 Indoor voltage transformers 2 TJC 4 INDOOR VOLTAGE TRANSFORMERS Parameters Highest voltage for equipment Power frequency test voltage, 1 min. Lightning impulse test voltage

More information

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide 1ZSE 2750-106 EN, REV. 7 Oil SF 6 bushings type GOEK Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.

More information

Medium voltage compact switchgears. rated voltage 12 and 25 kv rated current 400 and 630 A

Medium voltage compact switchgears. rated voltage 12 and 25 kv rated current 400 and 630 A Medium voltage compact switchgears rated voltage 12 and 25 kv rated current 400 and 630 A 1 General The new air-insulated DRIESCHER medium voltage compact switchgears are ideal for application in secondary

More information

Manual motor starter MS116

Manual motor starter MS116 Data sheet Manual motor starter MS116 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less

More information

Low Voltage Systems MNS and MNS is PowerCenter

Low Voltage Systems MNS and MNS is PowerCenter Low Voltage Systems MNS and MNS is PowerCenter For our customers, it s all about saving space maximizing functionality for power distribution systems while reducing equipment footprint. ABB has answered

More information

Switchgear Type 8BT1, up to 24 kv, air-insulated. Medium Voltage Switchgear Catalog HA 26.

Switchgear Type 8BT1, up to 24 kv, air-insulated.   Medium Voltage Switchgear Catalog HA 26. www.siemens.com/medium-voltage-switchgear Switchgear Type 8BT1, up to 24 kv, air-insulated Medium Voltage Switchgear Catalog HA 26.31 2012 Answers for infrastructure and cities. R-HA26-013. eps Contents

More information

SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv

SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv Three-phase Encapsulated Type SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv 06B1-E-0020 Small Space Requirement, High Reliability and Safety ー 72.5 to 145kV GIS, SDH714 The number of application

More information

Product information. ECOSS Electronic compact starter for wound rotor drives

Product information. ECOSS Electronic compact starter for wound rotor drives Product information ECOSS Electronic compact starter for wound rotor drives Controlled and safe start-up of wound rotor drives Electronic compact starters are used when slip-ring motors have to be started

More information

SF6 GAS INSULATED METAL ENCLOSED SWITCHGEAR (GIS)

SF6 GAS INSULATED METAL ENCLOSED SWITCHGEAR (GIS) SF6 GAS INSULATED METAL ENCLOSED SWITCHGEAR (GIS) About company The «Elektroapparat» plant starts its operation in 1922 as a plant manufacturing high-voltage electrical equipment. During the first two

More information

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR ANGLER SWITCHING DEVICES CONTENTS 1. General 2. Switchgear Types - Switch Disconnector - Disconnector 3. Cubicle Types - Cubicle with Switch Disconnector

More information

the safe, reliable, and efficient choice for MV switchgear

the safe, reliable, and efficient choice for MV switchgear Power Xpert UX IEC Medium Voltage switchgear Tested to IEC 62271-200 17.5 kv up to 50 ka - 3 s 24 k V up to 25 ka - 3 s Air insulated switchgear Internal arc classified LSC2B-PM UX the safe, reliable,

More information

UniGear. Technical Guide

UniGear. Technical Guide UniGear Technical Guide CONTENTS 0 CONTENTS 1.1 Compartments 1/2 1.2 Components of the structure 1/3 1.2.1 Hot-galvanized steel sheet 1/3 1.2.2 Painted steel sheet 1/4 1.2.3 Copper 1/5 1.2.4 Insulating

More information

Metal Clad Switchgears

Metal Clad Switchgears SNC Series Metal Clad Switchgears > up to 36 kv Rated Voltage > up to 2500 A Rated Current > up to 40 ka Rated Short Time Withstand Current > LSC-2B, PM, AFLR > In Confirmity with IEC 62271-1, 100, 102,

More information

Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Medium-Voltage Switchgear.

Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Medium-Voltage Switchgear. Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Medium-Voltage Switchgear www.siemens.com/energy Technology s Contents Application Page Benefits 2 Typical uses 2 and 3 Technical

More information

24kV Medium Voltage Switchgear Metal-Enclosed (LSC2A)

24kV Medium Voltage Switchgear Metal-Enclosed (LSC2A) M6 24kV Medium Voltage Switchgear MetalEnclosed (LSC2A) GENERAL FEATURES GENERAL DESCRIPTION The structure of the cubicles, of considerable strength, has selfsupporting structure and is made of steel sheet

More information

Benefits, typical uses

Benefits, typical uses R-HA26-013. eps Switchgear Type 8BT1, up to 24kV,Air-Insulated Contents Application Page Application Benefits 2 Typical uses 2 and 3 Technical Data Ratings 4 Classification, dimensions, 5 room planning

More information

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment)

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment) TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment) 1 SCOPE OF SUPPLY This specification covers design, manufacture, shop

More information

Valve Blocks. For direct flanging to pressure and differential pressure transmitters. Drop-forging housing. Replaceable valve seat

Valve Blocks. For direct flanging to pressure and differential pressure transmitters. Drop-forging housing. Replaceable valve seat Data Sheet 10/14-5.32-EN Valve Blocks For direct flanging to pressure and differential pressure transmitters Drop-forging housing Replaceable valve seat Valve stem with back-flow seal and crimped valve

More information

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy Our brand A strong brand for strong products: The ENERGOLINE brand represents our product portfolio of INDUSTRIAL SWITCHGEAR SYSTEMS. Our products are characterized by a high degree of safety, flexibility

More information

Product brochure. Gas-insulated switchgear ELK-04 C, 145 kv Modular and reliable

Product brochure. Gas-insulated switchgear ELK-04 C, 145 kv Modular and reliable Product brochure Gas-insulated switchgear ELK-04 C, 145 kv Modular and reliable ABB and 50 years of GIS innovation ABB is a leader in power and automation technologies that enable utility and industry

More information

Catalogue March InLine II - ZLBM/ZHBM Fuse Switch Disconnector

Catalogue March InLine II - ZLBM/ZHBM Fuse Switch Disconnector Catalogue March 2015 InLine II - ZLBM/ZHBM Fuse Switch Disconnector 2 1SEC312022B0202 ABB Catalogue Contents Introduction 1 Apparatus 2 Accessories 3 Technical Data 4 Cable terminations and cable shrouds

More information

ATR-MIX. METAL ENCLOSED SWITCHGEAR kV A ka

ATR-MIX. METAL ENCLOSED SWITCHGEAR kV A ka ATR-MIX METAL ENCLOSED SWITCHGEAR 12-24-36kV 630-1250 A 16-20-25 ka INDICE 01 GENERAL DESCRIPTION TECHNICAL DATA UNIT TYPES TYPICAL UNITS - ATR 01 TYPICAL UNITS - ATR 02 TYPICAL UNITS - ATR 03 TYPICAL

More information

ABB cable glands SCG series Stainless Steel 316L, general purpose cable glands

ABB cable glands SCG series Stainless Steel 316L, general purpose cable glands 1 TEHNIL DT SHEET cable glands SG series Stainless Steel 316L, general purpose cable glands Stainless steel cable glands for general purpose use, OEM, industrial and commercial applications, where a high

More information

Medium Voltage Distribution PIX. Air Insulated Switchgear up to 24 kv PARS TABLEAU

Medium Voltage Distribution PIX. Air Insulated Switchgear up to 24 kv PARS TABLEAU Medium Voltage Distribution PIX Air Insulated Switchgear up to kv PIX Air Insulated Switchgear up to kv The PIX system has been designed in accordance with international (IEC) standards, and gives an optimal

More information

Medium voltage switchgear type W 12. rated voltage 12 kv rated current 630 A

Medium voltage switchgear type W 12. rated voltage 12 kv rated current 630 A Medium voltage switchgear type W rated voltage kv rated current 0 A General The metal-encapsulated, air-insulated medium voltage switchgears, type W are for universal application. They range from compact

More information

Vmax Medium voltage vacuum circuit-breakers. IEC: kv; A; ka ANSI: kv; A; ka

Vmax Medium voltage vacuum circuit-breakers. IEC: kv; A; ka ANSI: kv; A; ka Medium voltage products Vmax Medium voltage vacuum circuit-breakers IEC:... 17.5 kv;... 1250 A;... 31.5 ka ANSI:... 15 kv;... 1200 A;... 31.5 ka The new Vmax circuit-breakers are the synthesis of ABB s

More information

Switchgear Type 8DJH for Secondary Distribution Systems up to 24 kv, Gas-Insulated

Switchgear Type 8DJH for Secondary Distribution Systems up to 24 kv, Gas-Insulated Catalog HA 40.2 Edition 2017 Switchgear Type 8DJH for Secondary Distribution Systems up to 24 kv, Gas-Insulated Medium-Voltage Switchgear siemens.com/8djh Application Typical uses R-HA40-111.tif R-HA40-112.tif

More information

Medium-Voltage Switchgear and Switches

Medium-Voltage Switchgear and Switches edium-voltage Switchgear and Switches G edium-voltage Switchgear up to 6 kv, 2.500A Product overview Switchgear for primary distribution level type CPG.0, CPG.1, AC Switchgear for secondary distribution

More information

36kV Gas Insulated Medium Voltage Switchgear

36kV Gas Insulated Medium Voltage Switchgear GE Industrial Solutions 36kV Gas Insulated Medium Voltage Switchgear User Manual Safety first! Important recommendations: Switchgear should be installed in a clean, dry, ventilated room suitable for electrical

More information

Selective main circuit breakers S 750 series Technical Data

Selective main circuit breakers S 750 series Technical Data Selective main circuit breakers S 750 series Technical Data When connecting aluminium conductors ( 4 mm 2 ) ensure that the contact surfaces of the conductors are cleaned, brushed and treated with grease.

More information

Product brochure. Gas-insulated switchgear ELK-04 C, 145 kv Modular and reliable

Product brochure. Gas-insulated switchgear ELK-04 C, 145 kv Modular and reliable Product brochure Gas-insulated switchgear ELK-04 C, 145 kv Modular and reliable ABB and 50 years of GIS innovation ABB is a leader in power and automation technologies that enable utility and industry

More information

Air-insulated medium voltage switchgear metal-enclosed type-tested factory-assembled withdrawable-unit design 12 kv / 24 kv

Air-insulated medium voltage switchgear metal-enclosed type-tested factory-assembled withdrawable-unit design 12 kv / 24 kv Air-insulated medium voltage switchgear metal-enclosed type-tested factory-assembled withdrawable-unit design 12 kv / 24 kv Leukhardt...switch to safety! Version 2.07.EN of 28.11.2011 page 1 of 9 Standards

More information

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide 1ZSE 2750-112 EN, REV. 4 Wall bushings type GSA-AA Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.

More information

CPG.0 Single busbar gas-insulated cubicles

CPG.0 Single busbar gas-insulated cubicles MV Switchgear Primary Distribution CPG.0 Single busbar gas-insulated cubicles Up to 36 kv CPG System The quality of products designed, manufactured and installed by Ormazabal is underpinned by the implementation

More information

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489 MINIATURE CIRCUIT BREAKERS SU200M Datasheet Branch protection acc. to CSA C22.2 No.5 / UL 489 The miniature circuit breaker SU200 M is ABB s solution for UL 489 branch circuit protection up to 480 Y/277

More information

Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability

Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability ABB innovations for changing demands ABB (www.abb.com) is a leader in power and automation technologies that enables utility

More information

B kv Gas-insulated Substations

B kv Gas-insulated Substations 72.5 145 kv Gas-insulated Substations The increasing demand for electrical power in cities and industrial centres requires the installation of a compact and efficient distribution and transmission network.

More information

Switchgear Type 8DJH 36 for Secondary

Switchgear Type 8DJH 36 for Secondary Catalog HA 40.3 Edition 2017 Switchgear Type 8DJH 36 for Secondary Distribution Systems up to 36 kv, Gas-Insulated Medium-Voltage Switchgear siemens.com/8djh36 Application Typical uses R-HA40-135.tif R_HA40-150a

More information

Protection and Connection Motorized and automatic transfer switches IEC Technical guide

Protection and Connection Motorized and automatic transfer switches IEC Technical guide Protection and Connection Motorized and automatic transfer switches IEC 61439 Technical guide Motorized change-over switches Uninterrupted power supply with motorized functionality ABB offers a wide variety

More information

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications Data Sheet System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications 2CDC021031S0011 2CDC021033S0011 The miniature circuit breaker S 200 M UC extends the established ABB System

More information

DIRECT CONTACT. Switchgear Sales Team TEL : ~9 CHANGWON PLANT Switchgear Design Team TEL : ~9

DIRECT CONTACT. Switchgear Sales Team TEL : ~9 CHANGWON PLANT Switchgear Design Team TEL : ~9 HEAD OFFICE 450, Gongdeok-Dong, Mapo-Gu, Seoul, Korea 121-720 TEL : 82-2-707-7000 R&D CENTER 183, Hogye-Dong, Dongan-Gu, Anyang-Shi, Gyeonggi-Do, Korea 431-080 TEL : 82-31-428-1000 CHANGWON PLANT 454-2,

More information

MEDIUM VOLTAGE PRODUCTS. Powerbloc Pre-assembled modules for building medium voltage switchgear

MEDIUM VOLTAGE PRODUCTS. Powerbloc Pre-assembled modules for building medium voltage switchgear MEDIUM VOLTAGE PRODUCTS Powerbloc Pre-assembled modules for building medium voltage switchgear Powerbloc are the ideal solution for replacing fixed circuit breakers with withdrawable circuit breakers,

More information

SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation. SYSclad 12 17,5kV A.

SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation. SYSclad 12 17,5kV A. SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation 630 3150A SYSclad 12 17,5kV 16 31,5kA Generalities SYSclad is a medium voltage switchboard metal clad

More information

1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide

1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide 1ZSC563-AAA EN, REV. 7 Transformer bushings type GSBK Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.

More information

Switchgear Type 8DJH for Secondary Distribution Systems up to 24 kv, Gas-Insulated

Switchgear Type 8DJH for Secondary Distribution Systems up to 24 kv, Gas-Insulated Switchgear Type 8DJH for Secondary Distribution Systems up to 24 kv, Gas-Insulated Medium-Voltage Switchgear Catalog HA 40.2 2010 Answers for energy. -HA40-110.eps -HA40-109.eps -HA40-112.eps -HA40-111.eps

More information

US Panorama. New SACE Emax 2 UL 1066 From Circuit Breaker to Power Manager

US Panorama. New SACE Emax 2 UL 1066 From Circuit Breaker to Power Manager US Panorama New SACE Emax 2 UL 1066 From Circuit Breaker to Power Manager Circuit breakers switch power SACE Emax 2 manages it Emax 2 is the new benchmark of power circuit breakers that not only monitors

More information

MEDIUM VOLTAGE PRODUCT. KECA 250 B1 Current Sensor Instructions for installation, use and maintenance

MEDIUM VOLTAGE PRODUCT. KECA 250 B1 Current Sensor Instructions for installation, use and maintenance MEDIUM VOLTAGE PRODUCT KECA 250 B1 Current Sensor Instructions for installation, use and maintenance 2 KECA 80 C184; KECA 80 C216 CURRENT SENSORS INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE Scope

More information

Mini contactors B6, BC6 with 3 pole

Mini contactors B6, BC6 with 3 pole Data sheet Mini contactors B6, BC6 with 3 pole Mini contactors from ABB are used for remotely ling motors and other loads wherever space is at a premium. These devices feature hum free coils, shallow depth,

More information

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077 Data Sheet System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077 2CDC021026S0011 2CDC021016S0012 The S 200 PR is a high-performance supplementary protector with

More information

24 k B788 ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH

24 k B788 ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH 788 Instructions for Installation, Operation and Maintenance for DRIESCHER - Air - Insulated Medium - Voltage Compact Switchgears for Substations Rated voltage 12 kv and 24 kv Rated current 630 A 24 k

More information