Transmitting Transducer. Gas/Air Velocity Range:
|
|
- Tyrone Cunningham
- 5 years ago
- Views:
Transcription
1
2 RNG Series Insertion-Style Gas Flow Meter The RNG Series meter is an insertion-style vortex shedding flow meter designed to offer high accuracy measurements over an extremely large flow range. The meters have no moving parts and are virtually maintenance-free. The RNG Series is suitable for most gas types, including air, natural gas, digester gas and `biogas applications. All meters in this series are loop-powered devices with standard HART communications for ease of field programming and system integration. Operating Principle An everyday example of a vortex shedding phenomenon is a flag waving in the breeze: the flag waves due to the vortices shed by air moving across the flagpole. Within the flow meter, as flowing gas moves across the tiny strut or bluff bar, vortices are also shed but on a smaller scale. The meter transmits an ultrasonic beam through the vortex pattern downstream of the strut. As vortices are shed, the carrier wave of the ultrasonic signal is modified. This change in the carrier wave is measurable and moves in proportion to the number of vortices shed. Digital processing enables the vortices to be counted, and this value is converted into a velocity. Software converts velocity into a volumetric flow rate, in units of measure selected by the operator. Racine Vortex flow meters utilize the smallest strut in the industry, which allows for high sensitivity; superior performance at very low flow rates; large turndown ratios; and low pressure drop. Through the use of an internal RTD and an external pressure sensor (optional), the flow meter software will compensate for changes in pressure and temperature, to achieve an accurate mass flow measurement. Transmitting Transducer FLOW Flow Meter Selection Racine vortex offers a sophisticated software program to aid in the flow meter selection process. The program accounts for system pressure and temperature, as well as media density, viscosity and specific gravity. Select from a complete list of Metric and English engineering units, using default or customized reference standards for pressure and temperature. This program may be downloaded at no charge from Small Strut Specifications Shed Vortices Receiving Transducer Measured: Gas/Air Velocity Range: to 40 FPS (0.6 to 4 MPS) Operating Temperature: -0 F to 00 F (-8 C to 50 C) Ambient Temperature Limits: -0 F to 55 F (-8 C to 68 C) Operating Pressure: -5 to 50 PSIG (-.4 to 7. BARg) Humidity: Up to 95%, non-condensing Accuracy: ±% of reading over the upper 90% of the flow range Repeatability: 0.5% of reading Input Power: 4 VDC Signal Output: -wire, 4-0 ma loop Construction: Stainless steel wetted parts with Teflon transducers, Viton o-rings, NEMA 7 transmitter enclosure Standard: Optional: " 50# ANSI Flange " 00# ANSI Flange " MNPT Coupling DN 50 Metric Flange Communications: HART Protocol (Via PC with HART Modem) Certifications: CE: EN66-:00 Optional Intrinsically Safe conforms to: ATEX II G Ex ib IIB T4 Zone Group IIB T4 (Canada) and AEx ib IIB T4 (USA) Options: line, 8 digit rate/totalizer display Internal RTD, temperature compensation for mass flow measurement Remote mount electronics Tel:
3 Flow Ranges* Flow Range in, 60 F in AIR Flow Range in Nm /hr, 6 C in AIR Pipe " 76 mm 4" 0 mm 6" 5 mm 8" 0 mm 0" 54 mm " 05 mm PRESSURE IN PSIG (BARg) 0 (0) 5 (.7) 50 (.4) 75 (5.) 00 (6.9) 5 (8.6) 50 (0.) 00 (.8) 50 (7.) *Consult RACINE Flow Meter Sizing Software for temperature and pressure conditions other than those listed here, available at Consult factory for larger pipe sizes **Pressure drop data for air at 4.7 psig and 60 F (0 BARg and 6 C) Pressure Drop (Inches H O) at 50% Max. Flow** Part Number Construction RNG Series Insertion Flow Meters for Gas R N G a a - b b b c d e f Racine Insertion Gas Stem Length Mounting Style/ Cable Length Meter Material Display Mass Flow Comp. All meters include 4-0 ma output, HART Communication Protocol and NEMA 7 XP transmitter enclosure Part Number: aa Stem Length ) " Stem 4) 4" Stem 6) 6" Stem 48) 48" Stem 60) 60" Stem RN bbb Mounting Style/ Cable Length 50) " x 50# Flange 5) " x 50# Flange + 0' cable 5) " x 50# Flange + 5' cable 5) " x 50# Flange + 50' cable 00) " x 00# Flange 0) " x 00# Flange + 0' cable 0) " x 00# Flange + 5' cable 0) " x 00# Flange + 50' cable NPT) " MNPT Fitting NP) " MNPT Fitting + 0' cable NP) " MNPT Fitting + 5' cable NP) " MNPT Fitting + 50' cable D50) DN 50 Flange D5) DN 50 Flange, + 0' cable D5) DN 50 Flange, + 5' cable d Display N) No Display D) Integral 8-Digit LCD, Indicator and Totalizer 4 c Meter Material S) 6 Stainless Steel (standard) T) PTFE Coated, Wetted Components f S) Standard (CE only) A) ATEX Ex II G ib IIB T4 e Mass Flow Compensation N) No Temperature Input or Mass Flow Compensation T) Integral RTD, Temperature Compensation for Mass Flow Measurement 5 Integral mount transmitter Remote mount transmitter (Not available with Intrinsically Safe version) Flange to DIN 57 specifications 4 Not available with Intrinsically Safe version 5 Pressure compensation requires external pressure sensor Fax:
4 Dimensional Drawings Model RNG RNG4 RNG6 RNG48 RNG60 DIM A NOMINAL (05) 4 (60) 6 (94) 48 (9) 60 (54) Inches (mm) DIM B. (7) 5. (64) 7. (946) 49. (5) 6. (556) DIM C. (565) 4. (870) 46. (75) 58. (480) 70. (784) 5.5 (46) (4) ¾ -4 NPT Pipe Plug 4.75 (0.64).5 (6.54) at Maximum Insertion.75 (9) Compression Fitting C Fully Retracted A B Fully Inserted (4) Flow Direction Measuring Window 865 Washington Avenue Racine, WI USA vortex@racinefed.com Racine is a trademark of Racine Federated Inc. HART is a registered trademark of the HART Communications Foundation. TEFLON and VITON are registered trademarks of DuPont Dow Elastomers. UL is a registered trademark of Underwriters Laboratories. CSA is a registered trademark of Canadian Standards Association. 00 Racine Federated Inc., all rights reserved. R NG / 4 Toll Free (US & Canada): 888-5RACINE (57-46)
5 Vortex Flow Meters RWG & RWBG Series Wafer-Style Gas Flow Meter Applications: Combustion air Compressed air Incineration gas Natural gas Nitrogen Digester gas (BioGas: CH4 + CO) Chemical processing Low pressure drop NIST traceable calibration HART Communications Protocol racinevortex.com Toll Free: 888-5RACINE
6 RWG & RWBG Series Wafer-Style Gas Flow Meter The RWG and RWBG Series meters are wafer-style in-line flow meters designed to offer high accuracy measurements with extremely low pressure drop. The meters have no moving parts and are virtually maintenance-free once installed. The RWG series is suitable for most gas types. The RWBG series is similar in construction but optimized for low-pressure BioGas applications, typically CH 4 + CO mixtures. All meters in these series are loop-powered devices with standard HART communications for ease of field programming and system integration. Operating Principle An everyday example of a vortex shedding phenomenon is a flag waving in the breeze: the flag waves due to the vortices shed by wind moving across the flagpole. Within the flow meter as flowing media moves across the strut or bluff bar, vortices are also shed but on a smaller scale. The meter transmits an ultrasonic beam through the vortex pattern downstream of the strut. As vortices are shed the carrier wave of the ultrasonic signal modulates. The modulation of the carrier wave is measurable and proportional to the number of vortices shed. Digital processing enables the vortices to be counted, and this value is converted into a velocity. Software converts velocity into a volumetric flow rate, in units of measure selected by the operator. Racine Vortex flow meters utilize the smallest strut in the industry, which allows for high levels of sensitivity; superior performance at low flow rates; high turndown ratios; and low pressure drop. Through the use of an internal RTD and an external pressure sensor (optional), the flow meter software will compensate for changes in pressure and temperature, to achieve an accurate mass flow measurement. FLOW Small Strut Flow Ranges* Shed Vortices Based on air, 60 F (6 C) Transmitting Transducer Receiving Transducer Specifications Measured: Flow Ranges: Operating Temperature: Gas/Air 0.4 to 6 through 0 to 600 acfm -0 F to 60 F (-8 C to 8 C) Ambient Temperature Limits: -0 F to 55 F (-8 C to 68 C) Operating Pressure: -5 to 50 PSIG (-.4 to 7. Barg) Accuracy: ±% of reading over the upper 90% of the flow range Repeatability: 0.5% of reading Input Power: 4 VDC Signal Output: -wire, 4-0 ma loop Construction: Stainless steel wetted parts with ceramic transducers (Teflon in RWBG Series), Viton o-rings, NEMA 7 XP enclosure standard Communications: HART Protocol (via PC with HART Modem) Certifications: CE: EN66-:00 Optional Intrinsically Safe conforms to: ATEX II G Ex ib IIB T4 Zone Group IIB T4 (Canada) and AEx ib IIB T4 (USA) Options: line, 8-digit rate/totalizer display Integral RTD temperature compensation for mass flow measurement Remote mount electronics Wafer body suitable for DN Flange installation Pipe ½" " ½" " " 4" Flow Range Nm /Hr Nm /Hr Nm /Hr Nm /Hr Nm /Hr Nm /Hr PRESSURE PSIG (Barg) 0 (0) 5 (.7) 50 (.4) 75 (5.) 00 (6.9) 50 (0.) 00 (.8) 50 (7.) *Consult RACINE Flow Meter Sizing Software (available at for temperature and pressure conditions other than those listed here Tel:
7 Pressure Drop At Full Flow ( STP) Part Number Construction Inches H 0 kpa Air CH 4 Air CH RWG Series Wafer Flow Meters for Gas d d e e e S g h i Racine Wafer Gas Meter Mounting Style Meter Material Display Mass Flow Comp. All meters include 4-0 ma output, HART communications protocol and NEMA 7 XP Transmitter Enclosure Part Number: dd Meter 05) ½" wafer 0) " wafer 5) ½" wafer 0) " wafer 0) " wafer 40) 4" wafer eee Mounting Style/ Cable Length MET) Meter Mount (integral mount, NEMA 7 XP Enclosure transmitter) R0) Remote Mount w/0' cable R5) Remote Mount w/ 5' cable R50) Remote Mount w/ 50' cable F5) 50# Flanges + Meter Mount F0) 00# Flanges + Meter Mount 0R) 50# Flanges + Remote Mount w/ 0' cable 0R) 50# Flanges + Remote Mount w/ 5' cable 0R) 50# Flanges + Remote Mount w/ 50' cable R) 00# Flanges + Remote Mount w/ 0' cable R) 00# Flanges + Remote Mount w/ 5' cable R) 00# Flanges + Remote Mount w/ 50' cable S Meter Material S) 6SS (standard) g Display N) No Display D) Integral 8-Digit Totalizer LCD Indicator i S) CE (Standard) A) Intrinsically Safe h Mass Flow Compensation N) No Temperature Input, No Compensation for Mass Flow Measurement T) Integral RTD, Temperature Compensation for Mass Flow Measurement Not available with Intrinsically Safe version Includes ¼" NPT port (plugged) for external pressure sensor Also required when external pressure sensor will be used RWBG Series Wafer Flow Meters for BioGas R W BG d d - MET S N h A Racine Wafer BioGas Meter Mounting Style Meter Material Reserved Mass Flow Comp. Optimized for BioGas (CH4 + CO) Applications All meters include ATEX approval, 4-0 ma output and HART communications protocol Part Number: dd Meter 05) ½" wafer 0) " wafer 5) ½" wafer 0) " wafer 0) " wafer 40) 4" wafer Mounting Style/Cable Length MET) Meter Mount (integral mount, NEMA 7 XP Enclosure transmitter) Reserved N) Meter Material S) 6SS (standard) A) Intrinsically Safe h Mass Flow Compensation N) No Temperature Input, No Compensation for Mass Flow Measurement T) Integral RTD, Temperature Compensation for Mass Flow Measurement Also required when external pressure sensor will be used Fax:
8 Dimensional Drawings Inches (mm) Inches (mm) Model Meter Dia. A Dia. B Dim. C Dim. D Bolt Circle RWG/RWBG05 RWG/RWBG0 RWG/RWBG5 RWG/RWBG0 RWG/RWBG0 RWG/RWBG40 ½".86 X.86 (Square) () (7.6 X 7.6) (.7) (6) (57.) (60.5) " (5) (00.8) (.) (78) (57.) (79.4) ½" (8) (9.9) (4.9) (99) (57.) (98.4) " (5) (0.6) (44.5) (50) (57.) " (76) (.4) (69.9) (68) (57.) 4" (0) (7.5) (95.) (9) (57.) (4) (4) (4) ¾-4 NPT Pipe Plug ¾-4 NPT Pipe Plug ¾-4 NPT Pipe Plug Dia B Bolt Circle Dia B Bolt Circle Dia B.86 x.86 Square Dia A Dia A 5.75 (46) Flanged Series Meters* Inches (mm) 5.75 (46) 4.75 (0.6) C Cable Entry Accommodates Dia Cable ¾ - 4 NPT Port Flanges not Included SIZE ½" () " (5) ½" (8) " (5) " (76) 4" (0) DIM A RWG 05-F (4.) RWG 0-F (46.7) RWG 5-F5 6.4 (60.9) RWG 0-F5 5.9 (50.) RWG 0-F5 6.6 (68.0) RWG 40-F5 7.5 (90.8) DIM B (50-54) (50-54) (50-54) (50-54) (0-04) (0-04) 4.75 (0.6) A.06 D.06 (gasket) *50 lb RF ANSI Flange standard 00 lb RF ANSI Flange optional B Racine Flow Meter Group 865 Washington Avenue Racine, WI USA vortex@racinefed.com Racine is a trademark of Racine Federated Inc. HART is a registered trademark of the HART Communications Foundation. TEFLON and VITON are registered trademarks of DuPont Dow Elastomers. UL is a registered trademark of Underwriters Laboratories. CSA is a registered trademark of Canadian Standards Association. 00 Racine Federated Inc., all rights reserved. R WG / 4 Toll Free (US & Canada): 888-5RACINE (57-46)
Armstrong In-Line and Insertion Vortex Flow Meters
Armstrong In-Line and Insertion Vortex Flow Meters Designs, materials, weights and performance ratings are approximate and subject to change without notice. Visit for up-to-date information. 1 In-Line
More informationF-2600 SERIES INLINE VORTEX FLOW METER
F-2600 SERIES INLINE VORTEX FLOW METER APPLICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260
More informationMultivariable Vortex Flow Meter
Multivariable Vortex Flow Meter DVH Sensor Design w/o sealing Fully welded sensor Integrated temperature and pressure measurement (optional) Calculation of mass and density possible High temperature version
More informationSatellite photo of cloud vortices caused by a mountain (Courtesy of our friends at NASA) tekvorx Operation Showing Simplified Construction
Sensing the pulse of industry tekvorx TV01 Multivariable Vortex flow Sensors Vortex flow sensors derive their name from a natural phenomenon of fluid dynamics. When a gas or relatively low viscosity liquid
More informationMultivariable Vortex Flow Meter
Multivariable Vortex Flow Meter DVH Sensor Design w/o sealing Fully welded sensor Integrated temperature and pressure measurement (optional) Calculation of mass and density possible High temperature version
More informationF-2500 SERIES VORTEX METER
F-500 SERIES VORTEX METER APPLICATIONS Saturated steam Hot water to F (0 C) Applications with optional pressure sensor Superheated steam to F (0 C) Compressed air Industrial gases CALIBRATION Each meter
More informationF-2700 SERIES INSERTION VORTEX FLOW METER
F-2700 SERIES INSERTION VORTEX FLOW METER APPLICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260
More informationF-2700 SERIES INSERTION VORTEX FLOW METER
F-2700 SERIES INSERTION VORTEX FLOW METER CALIBRATION Every ONICON flow meter is wet calibrated in a flow laboratory against standards that are directly traceable to N.I.S.T. A certificate of calibration
More informationF-2600 SERIES INLINE VORTEX FLOW METER
F-2600 SERIES ININE VORTEX FOW METER APPICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260 C)
More informationVIM20 Vortex Insertion Flowmeter
VIM20 Principle of Operation Vortex flowmeters measure flows of liquid, gas and steam by detecting the frequency at which vortices are alternately shed from a bluff body. According to proven laws of physics,
More informationVortex Flow Meter Model DVH
Vortex Flow Meter measuring monitoring analysing DVH Measuring range: 3-8... 3057-280187 Nm³/h Accuracy: ± 0,7 % of reading (liquids) ± 1 % of reading (gases and steam) p max : 100 bar abs; t max : 400
More informationVortex In Line Flow Meter
Vortex In Line Flow Meter Principles of Operation Vortices are created when a fluid passes around a bluff body as shown below. Vortices are alternately shed on each side of the body, 0 degrees out of phase
More informationPro-V Multivariable Flowmeter Model M24 In-line Vortex
Pro-V Multivariable Flowmeter Model M24 In-line Vortex Pro-V TM Advantage: VorTek Instruments Pro-V multivariable flowmeters utilize three primary sensing elements a vortex shedding velocity sensor, an
More informationVORTEX IN-LINE FLOW METERS
VORTEX IN-LINE FLOW METERS Principles of Operation Vortices are created when a fluid passes around a bluff body as shown below. Vortices are alternately shed on each side of the body, degrees out of phase
More informationDVH. Vortex Flowmeter. Measuring range: Nm³/h. Accuracy: ± 0,7% of reading (liquids) ± 1% of reading (gases and steam) p max
Vortex Flowmeter measuring monitoring analysing DVH Measuring range: 3-8... 3057-280187 Nm³/h Accuracy: ± 0,7% of reading (liquids) ± 1% of reading (gases and steam) p max : 100 bar abs; t max : 400 C
More informationVortex In Line Flow Meter
Principles of Operation Vortices are created when a fluid passes around a bluff body as shown below. Vortices are alternately shed on each side of the body, 0 degrees out of phase to each other, resulting
More informationVortex Flowmeter Model DVE
Vortex Flowmeter Multi-Parameter measuring monitoring analysing DVE Measuring range Liquids: 5.2-157... 284-85371 m³/h Air: 89-1463... 26915-2467081 Nm 3 /h (20 C, 0 bar rel) Saturated steam: 81-938...
More informationVORTEX FLOW METTER DVH. Despriction. Advantages of the DVH Vortex Flow Meter
R VORTEX FLOW METTER DVH Measuring range: 3-8... 3 057-280 187 m3n/h Accuray: ± 0,7 % of reading (liquids) ± 1 % of reading (gases and steam) P m a x : 100 bar abs; tm ax : 400 C Connection: ANSI ½ up
More informationPanaFlow MV80. In-line Multivariable Flowmeter for Mass, Temperature, and Pressure. GE Sensing. Applications. Key Benefits
Key Benefits Multivariable vortex flowmeter for measuring volumetric flow, temperature, pressure, density, and mass flow using a single meter Measures most gases, liquids and steam without the need to
More informationVortex Flowmeters VFM 3100 F-T VFM 3100 W-T
KROHNE 10/2001 7.02313.23.00 GR/OP Vortex Flowmeters F-T W-T Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters Level measuring
More informationVLM20 In-line Vortex Flowmeter
ocal regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationF-1500 SERIES INSERTION TURBINE FLOW METER
F-1500 SERIES INSERTION TURBINE FLOW METER APPLICATIONS Saturated steam Hot water to 450 F (232 C) standard 850 F (454 C) optional Applications with optional pressure sensor Superheated steam to 450 F
More informationF-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)
F-1500 SERIES INSERTION TURBINE FLOW METER Insertion turbine flow meters are ideal for use in larger steam lines where downsizing the line size to improve flow measurement is not desirable. In these applications,
More informationKDM ARMORED FLOW METER & SWITCH
KDM ARMORED FLOW METER & SWITCH Flow Pressure Level Temperature measurement monitoring control S2 Short Installation Length SS, PTFE or Hastelloy Wetted Parts Analog Output Available 110 F to + 390 F Temperature
More informationLow Cost, Low Maintenance Air, Compressed Air and Nitrogen Flow Measurement for Process and Plant Applications
FCI ST50 Series Flow Meters Low Cost, Low Maintenance Air, Compressed Air and Nitrogen Flow Measurement for Process and Plant Applications FCI ST50 FLOW METER Wastewater Treatment Aeration Control Blower
More informationSTEEMCO Flowmeter for Steam
STEEMCO Flowmeter for Steam Typical Applications The STEEMCO flow meters measure the flow of saturated and superheated steam within the process industries, including chemical, petro-chemical, pharmaceutical
More informationHydro-Flow Model 3100 Retractable Insertion Vortex Flowmeter Installation and Operation Manual
Hydro-Flow Model 00 Retractable Insertion Vortex Flowmeter Installation and Operation Manual Table of Contents Model and Suffix Codes. Theory and Identification.. Installation Guidelines Mechanical Drawing:
More informationHydro-Flow Model 2300 Installation and Operation Guide B
Hydro-Flow Model 2300 Installation and Operation Guide 5700508-B Contents: Understanding and Identifying Your Flow Meter 1 Installing Your Flow Meter 3 Electrical Connections.. 7 Mechanical and Electrical
More informationHydro-Flow Model 2200 Installation and Operation Guide B
Hydro-Flow Model 2200 Installation and Operation Guide 5700507-B Contents: Understanding and Identifying Your Flow Meter 1 Installing Your Flow Meter 3 Making Electrical Connections. 7 Mechanical and Electrical
More informationVIM20 Vortex Insertion Flowmeter
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationThe readings you need, right where you need them. AX Series Vortex Meters
The readings you need, right where you need them. AX Series Vortex Meters Multivariable function from a single meter Vortex multivariable meters from Azbil North America employ three sensing elements in
More informationmass flowmeter for compressed air
mass flowmeter for compressed air VARIOMASS LC pressure and temperature compensated flowmeter easy and cost effective installation of the senor no pressure loss caused by the sensor no moving parts, i.e.
More informationInnova-Mass Model 240 & 241. Multivariable Mass Vortex Flow Meter. For information online...
Multivariable Mass Vortex Flow Meter Features Volumetric or mass flow monitoring of gases, liquids and steam Smart electronics extends range down to a Reynolds number of 5000 Ideal for steam applications
More informationGlass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases
Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases Easy installation Local indication by means of direct reading Low pressure drop Scales directly in l/h, m 3 /h, kg/h, l/min,
More informationSTEEMCO-MAS Flowmeter for Steam
STEEMCO-MAS Flowmeter for Steam Typical Applications The STEEMCO-MAS flow meters measure the mass flow of superheated steam within the process industries, including chemical, petro-chemical, pharmaceutical
More informationCANADA SENSORS TECHNOLOGY INC.
CANADA SENSORS TECHNOLOGY INC. Manufacturer of Advanced Technology Pressure & Level Transmitters LIQUID LEVEL TRANSMITTER PROCESS 10 HART Enabled Intrinsically Safe Model Submersible Pump Lift Station
More informationVIM20 Vortex Insertion Flowmeter
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationSmart Pressure Transmitter
DOC. NO.: C3100L-E16B Smart Pressure Transmitter with Diaphragm Seal MODEL APT3100L DUON System Co., Ltd. 298-29, GONDAN-RO, GUNPO-SI, GYEONGGI-DO, KOREA 15809 Tel : +82-31-3-6100 Fax : +82-31-29-7200
More informationmass flowmeter for compressed air
mass flowmeter for compressed air VARIOMASS ECO pressure and temperature compensated easy and cost effective installation of the sensor no pressure loss caused by the sensor no moving parts, i.e. maintenance
More informationHydro-Flow Model 2200 Fixed Insertion Vortex Flowmeter Installation and Operation Manual
Hydro-Flow Model 00 Fixed Insertion Vortex Flowmeter Installation and Operation Manual Table of Contents Model and Suffix Codes. Theory and Identification.. Installation Guidelines 4 Mechanical Drawing:
More informationThe readings you need, right where you need them. AX Series Vortex Meters
The readings you need, right where you need them. AX Series Vortex Meters Multivariable function from a single meter Principles of Operation Vortex multivariable meters from Azbil North America employ
More informationThe EPSILON is based on the principle of measuring velocity in the pipe line, therefore the flow measurement is volumetric.
Typical Applications EPSILON Flowmeter The EPSILON flow meters measure the flow of most liquids and gases within the process industries, including chemical, petro-chemical, pharmaceutical and the power
More informationSIGNET 7002 Vortex Flow Sensor ENGLISH
SIGNET 7002 Vortex Flow Sensor ENGLISH 3-7002.090 C-7/02 English SAFETY INSTRUCTIONS 1. Do not remove from pressurized lines. 2. Never install sensor without O-Rings. 3. Confirm chemical compatibility
More informationHydro-Flow Model 3100
Hydro-Flow Model 3100 Installation and Operation Guide installation and operation guide Contents: Understanding Your Flow Meter... 1 Identifying Your Flow Meter...2 Installing Your Flow Meter...3,4 Making
More informationOperating Instruction for Plastic Vortex Flow Transmitter. Model: UV
Operating Instruction for Plastic Vortex Transmitter Model: UV DESCRIPTION INTRODUCTION The UV series vortex-shedding flow meter is a general-purpose electronic liquid flow meter. The standard output is
More informationProduct Data Sheet. VN2000 Flow Meters. Hot Tap Insertion Meter DESCRIPTION BENEFITS APPLICATIONS INSTALLATION OPERATION SIZING SOFTWARE
VN2000 Flow Meters Hot Tap Insertion Meter DESCRIPTION The VN2000 Hot Tap Insertion Vortex Flow Meter measures the volumetric flow, mass flow rate or BTU/energy of steam, gas or liquids over a large flow
More informationSmart Pressure Transmitter
DOC. NO.: C3500L-E16A Smart Pressure Transmitter with Diaphragm Seal MODEL APT3500L 298-29, GONDAN-RO, GUNPO-SI, GYEONGGI-DO, KOREA 15809 Tel : +82-31-3-6100 Fax : +82-31-29-7200 E-mail: autrol@duon.co.kr,
More informationSITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application
Overview SITRANS F flowmeters Application Liquid applications Gas applications Pipelines Custody transfer, allocation, Upstream Production wells, line balance, gathering, separation interface/densitometer
More informationOM004, OM006 & OM008 Oval Gear Meter
OM SERIES OM004, OM006 & OM008 Oval Gear Meter OM004 (1/8"), OM006 (1/4") and OM008 (3/8") Oval Gear Meters ACCURACY: ±1.0% OF READING Select Your Body Material: Aluminum or Stainless Steel The OM Small
More informationVersaFlow Vortex 100 Vortex Flow Meter Specifications
VersaFlow Vortex 100 Vortex Flow Meter Specifications 34-VF-03-05 May 2011 The All-In-One Solution The VERSAFLOW is the only vortex flowmeter with integrated and temperature compensation in 2- wire technology.
More informationInnovaMass 240 & 241. Multivariable Mass Vortex Flow Meter. FEATURES DESCRIPTION
Multivariable Mass Vortex Flow Meter FEATURES Mass and volumetric flow measurement of gas, liquid, and steam Multivariable outputs for five process parameters: mass flow rate volumetric flow rate temperature
More informationProduct Data Sheet. VN2000 Flow Meters. Compact Insertion Meter DESCRIPTION BENEFITS APPLICATIONS INSTALLATION
VN2000 Flow Meters Compact Insertion Meter DESCRIPTION The VN2000 Compact Insertion Vortex Flow Meter measures the volumetric or mass flow rate or BTU/energy of steam, gas or liquids over a large flow
More informationUser Manual. Intrinsically Safe Flow Meters. RWG/RWBG Wafer Style Flow Meters RNG Insertion Style Flow Meters. VRX-UM EN-03 (October 2014) Flow
Intrinsically Safe Meters RWG/RWBG Wafer Style Meters RNG Insertion Style Meters FLOW VRX-UM-00374-EN-03 () User Manual Intrinsically Safe Meters, RWG/RWBG Wafer Style Meters & RNG Insertion Style Meters
More informationSMARTLINK METER. Digital Self-checking Thermal Mass Flow Meter
Flow Control Components - SMARTLINK METER 10-30.9-1 SMARTLINK METER Digital Self-checking Thermal Mass Flow Meter Precise, repeatable mass flow measurement for fuel, air and combustion streams Displays
More informationDigital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series
Digital Vortex meter digitalyewflo Digital Vortex meter Series Unrivaled Performance, Functionality and Ease of Use Series Standard Type / Multi-variable Type High Temperature / Cryogenic Type Reduced
More informationLower maintenance costs: with no moving parts, there is nothing on the DFX to wear down. Wide measuring range: 0.15 to 30 FPS (0.05 to 9 MPS).
PRODUCT APPLICATIONS / APPLICATION QUALIFICATION DIMENSIONAL SPECIFICATIONS MECHANICAL DIMENSIONS: INCHES (mm) DOPPLER ULTRASONIC FLOW METER Carbonated liquids Mining slurry Drilling mud Coal-seam water
More informationRCM - Direct Reading Flowmeters
Compact Design Easy to Install Horizontal or Vertical Installation Flow Rates up to 3000 GPM (Liquid) or 20000 SCFM (Gas) Low Pressure Drop Optional Alarms and Output Signals Accuracy: ± 3% of full scale
More informationProduct Data Sheet. VN2000 Flow Meters. Wafer Plate Inline Meter DESCRIPTION BENEFITS OPERATION APPLICATIONS SIZING SOFTWARE
VN2000 Flow Meters Wafer Plate Inline Meter DESCRIPTION The VN2000 Wafer Plate Inline Flow Meter measures the volumetric or mass flow rate or BTU/energy of steam, gas or liquids over a large flow range.
More informationSMARTLINK METER. Digital Self-checking Thermal Mass Flow Meter
Flow Control Components - SMARTLINK METER 10-30.9-1 SMARTLINK METER Digital Self-checking Thermal Mass Flow Meter Precise, repeatable mass flow measurement for fuel, air and combustion streams Displays
More informationFeatures/Benefits INSTALL IT & FORGET IT FEATURES & BENEFITS
Features/Benefits INSTALL IT & FORGET IT The ForceMeter TM offers the same rugged design for which the Niagara Meters brand is known. The ForceMeter is ideal for applications including water, compressed
More informationOscillating piston flowmeters Series COVOL Positive displacement flowmeter for liquids
Oscillating piston flowmeters Series COVOL Positive displacement flowmeter for liquids Suitable for all kind of liquids Viscosity up to 120000 mpa s Excellent performance with changing process conditions
More informationMicro Motion 7827 Digital Viscosity Meter
Product Data Sheet PS-001217, Rev. C April 2013 Micro Motion 7827 Digital Viscosity Meter Micro Motion viscosity meters are built to tackle the most demanding process and control applications. Rugged and
More informationORIMAS Mass Flowmeter
Typical Applications ORIMAS Mass Flowmeter The ORIMAS mass flow meters measure the mass flow of most liquids and gases within the process industries, including chemical, petro-chemical, pharmaceutical
More informationMicro Motion F-Series Coriolis Flow and Density Meters
Product Data Sheet PS-00603, Rev. F December 2007 Micro Motion F-Series Coriolis Flow and Density Meters Micro Motion F-Series Coriolis meters offer highly accurate mass flow, volume flow, and density
More informationDW PADDLE-BELLOWS FLOWMETER & SWITCH
DW PADDLE-BELLOWS FLOWMETER & SWITCH Flow Pressure Level Temperature measurement monitoring control S3 Accuracy: ±3% Full Scale Excellent for Highly Contaminated Media Orientation Independent Brass or
More informationFCI ST50 Series Flowmeters Low Cost, Low Maintenance Air, Compressed Air and Nitrogen Flow Measurement for Process and Plant Applications
FCI ST50 Series Flowmeters Low Cost, Low Maintenance ir, Compressed ir and Nitrogen Flow Measurement for Process and Plant pplications Wastewater Treatment eration Control lower and Dryer ir Flow Control
More informationProduct Data Sheet , Rev GA Catalog Content
HIGHLY ACCURATE SMALL-BORE FLOW MEASUREMENT CAPABILITY WITH MINIMAL INSTALLATION AND MAINTENANCE REQUIREMENTS Improves accuracy and repeatability in 1 /2-in., 1-in., and 1 1 /2-in. line sizes Reduces leak
More information4.30 [109] 5.43 [138] FCI FlexMASSter ST98 Series: The Best Value in a 8.00 [203] High Performance. Flange. Mounting Hole. Positioning to Split Flow
ST 98 METER.31 [236] 9.31 [236] /D [2.54] / Compression Fitti Teflon or Metal Ferrul Teflon or Metal Ferrule [2.54] 7.50 [191] [171] Ø.80 Enclosure meets explosion proof, water & dust tight approvals (See
More informationOPTIMASS 3000 Technical Datasheet
OPTIMASS 3000 Technical Datasheet Sensor for mass flow First choice for low flow applications Certified secondary pressure containment A common footprint for all three sizes, in Hastelloy or Stainless
More informationHot Tap Insertion Vortex
Hot Tap Insertion Vortex Product Features The same insertion meter can measure Steam, Gases or Liquids. Standardize on an insertion bar that can measure line sizes 2 48 Heavy Duty & Maintenance Free Design
More informationTechnical Data. BiRotor Plus Positive Displacement Meter
Technical Data BiRotor Plus Positive Displacement Meter B27X 3 ANSI (DN80) B30X 6 ANSI (DN150) B28X 4 ANSI (DN100) B31X 8 ANSI (DN200) B29X 6 ANSI (DN150) B32X 10 ANSI (DN250) General The BiRotor Plus
More informationAr-Mite TM Low Flow Armored Flowmeter
Data Sheet Brooks Ar-Mite TM MT 3750C Ar-Mite TM Low Flow Armored Flowmeter Ar-Mite TM Model MT 3750 Metal Tube Flowmeter Ar-Mite TM Model MT 3750 Metal Tube Flowmeter with Transmitter or Inductive Alarm
More informationVortex Flow Sensors VA Di also suitable for applications in condensation and particle laden gases. Drawing 1
Vortex Flow Sensors VA Di Vortex Flow Sensors VA Di also suitable for applications in condensation and particle laden gases Drawing 1 Measurable variable actual flow rate standard velocity standard flow
More informationMicro Motion ELITE Mass Flow and Density Meters
Product Data Sheet PS 00374, Rev. A July 2003 Micro Motion ELITE Mass Flow and Density Meters Available with MVD Technology! TM Micro Motion Micro Motion ELITE mass flow and density meters Experience the
More informationDW PADDLE-BELLOWS FLOWMETER & SWITCH
DW PADDLE-BELLOWS FLOWMETER & SWITCH Flow Pressure Level Temperature measurement monitoring control S3 Accuracy: ±3% Full Scale Excellent for Highly Contaminated Media Orientation Independent Brass or
More informationThermal Mass Flow Meter (Series MST)
Overview MaxiFlo TM MST series Thermal Mass Flow Meter is the instrument of choice for reliable and accurate measurement of mass flows for various gases. It measures the mass flow of gas based on constant
More information9900 Series Oval Flowmeter/Transmitter with SMART METER MANAGER
Design Specifications DS-9900 Revision 04 9900 Series Oval Flowmeter/Transmitter with SMART METER MANAGER 2-Wire loop powered flowmeter/transmitter 316 Stainless steel measuring unit Automatic temperature
More informationBARTON 7400 Precision Gas Turbine Flow Meters
TECHNICAL SPECIFICATIONS BARTON 7400 Precision Gas Turbine Flow Meters BARTON Model 7400 Precision Turbine Flow Meters are designed for gas service in a wide range of industrial, commercial, pipeline and
More informationMicro Motion ELITE Mass Flow and Density Meters
Product Data Sheet PS 00375 March 2002 Micro Motion ELITE Mass Flow and Density Meters Now available with MVD Technology! www.micromotion.com Micro Motion ELITE Meters Experience the most accurate Coriolis
More informationOPTISWIRL 4070 Technical Datasheet
OPTISWIRL 4070 Technical Datasheet Vortex flowmeter Integrated pressure and temperature compensation Temperature compensation for saturated steam included as standard All OPTISWIRL versions in 2-wire technology
More informationF L O W M E T E R I N G E Q U I P M E N T Model AR Ellipse Annular Flow Meter Preso s patented elliptical design outperforms and provides greater accuracy than traditional differential pressure flow measurement
More informationtekson TS Series Low Cost Ultrasonic Water Energy Flow Measurement
Sensing the pulse of industry tekson TS Series Low Cost Ultrasonic Water Energy Flow Measurement tekflo sensors are proud to present their tekson TS Series ultrasonic water energy meter, which uniquely
More informationVortex Eggs Delta Flowmeter
Product Data Sheet PDS-FLM Vortex Eggs Delta Flowmeter Technical Specifications (Liquid, Gas & Air) Easy to read Free positioning EEPROM DESCRIPTION The unique sensor body and transmitter design makes
More informationFH8500. Metering Solution for Custody Transfer Applications. One Step Ahead in Ultrasonic Flowmetering. Main Applications
FH85 Metering Solution for Custody Transfer Applications One Step Ahead in Ultrasonic Flowmetering Main Applications Oil Production & Allocation FSO, FPSO Metering Tanker Off-loading Storage Management
More informationProMinent EXtronic Solenoid Diaphragm Metering Pumps
Overview: EXtronic Ideal for explosion-proof applications (see page 126 for spare parts) The ProMinent EXtronic series represents a proven technology for metering liquid media in hazardous areas classified
More informationRosemount 3051CFA Annubar Flowmeter
December 2013 Rosemount 3051 Rosemount 3051CFA Annubar Flowmeter The Rosemount 3051CFA Annubar Flowmeter utilizes the patented T-shaped sensor design that delivers best in class accuracy and performance.
More informationSentinel. Panametrics Custody Transfer Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features
Applications The Sentinel flowmeter is a complete ultrasonic flowmeter system for the measurement of natural gas flow applications such as: Custody transfer Transmission and distribution Underground storage
More informationAir Inlet/ Discharge Port
Metering Pumps The ProMinent is a pneumatically-actuated metering pump with a capacity in the 0.1 to 3.9 gph (0.24 to 14.8 l/h) range at maximum backpressures of 21 to 232 psig (0.9 to 16 bar). The consists
More informationLow Profile Insertion Vortex
Low Profile Insertion Vortex Product Features The same insertion meter can measure Steam, Gases or Liquids. Standardize on an insertion bar that can measure line sizes 2 24 Heavy Duty & Maintenance Free
More informationJUMO dtrans p02. Pressure transmitter. General application. Approvals/marks of conformity. Data Sheet Page 1/6. II 1/2G Ex ia IIC T6 Ga/Gb
sales@jumo.co.uk info@jumo.us Data Sheet 404385 Page 1/6 JUMO dtrans p02 Pressure transmitter II 1/2G Ex ia IIC T6 Ga/Gb General application The pressure transmitter Type JUMO dtrans p02 is used to measure
More informationRCM. Direct Reading Flowmeter. for Liquids or Gases
Direct Reading Flowmeter for Liquids or Gases measuring monitoring analyzing RCM Compact Design Easy to Install Horizontal or Vertical Installation Flow Rates up to 3000 GPM (Liquid) or 20000 SCFM (Gas)
More informationMid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter
BULLETIN NO. 220/11 (SUPERSEDES BULLETIN NO. 220/06) Mid-West Instrument Piston Type Model 220 Hazardous Locations Indicating / Non-Indicating Differential Pressure Switch or Transmitter Low cost piston
More informationSITRANS F X SITRANS FX300 3/355
Siemens AG 204 Flow Measurement Overview vortex flowmeters provide accurate volumetric and mass flow measurement of steam, gases and liquids as an all-in-one solution with integrated temperature and pressure
More informationProMinent EXtronic Solenoid Diaphragm Metering Pumps
Overview: EXtronic Ideal for explosion-proof applications (see page 128 for spare parts) The ProMinent EXtronic series represents a proven technology for metering liquid media in hazardous areas classified
More informationDW PADDLE-BELLOWS FLOWMETER & SWITCH
DW PADDLE-BELLOWS FLOWMETER & SWITCH Flow Pressure Level Temperature measurement monitoring control Accuracy: ±% Full Scale Excellent for Highly Contaminated Media Orientation Independent Brass or Stainless
More informationL E V E L P L U S M - S E R I E S ANALOG
L E V E L P L U S M - S E R I E S ANALOG P r o d u c t S p e c i f i c a t i o n s NEMA 4X Housing, Sanitary Gauge Single Chamber Housing, Rigid Gauge Dual Chamber Housing, Flexible Gauge Level Plus M-Series
More informationMid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter
BULLETIN NO. 240/11 (SUPERSEDES BULLETIN NO. 240/06) Mid-West Instrument Diaphragm Type Model 240 Hazardous Locations Indicating / Non-Indicating Differential Pressure Switch or Transmitter Field wireable
More informationSarasota FD900 Sarasota ID900 Sarasota PD900 Gas Density Meters for Gas Metering and Control
Sarasota FD900 Sarasota ID900 Sarasota PD900 Gas Density Meters for Gas Metering and Control The Sarasota range of gas density meters meets the challenges of fiscal/custody transfer gas metering, liquefied
More informationSmart Pressure Transmitter
DOC. NO.: C3200L-E16B Smart Pressure Transmitter with Diaphragm Seal MODEL APT3200L DUON System Co., Ltd. 298-29, GONDAN-RO, GUNPO-SI, GYEONGGI-DO, KOREA 15809 Tel : +82-31-3-6100 Fax : +82-31-29-7200
More informationSITRANS FX300 4/289. System Overview. Overview
Siemens G 2008 SITRNS F flowmeters Overview System Overview Version Single transmitter Dual transmitter Options Standard Pressure sensor Flange Pressure sensor and isola- Standard tion valve Sandwich vortex
More information