JOSLYN. Underground Cable Accessories. Table of Contents. JPT/JIPT Polymer Terminations. ShrinkTite Sealing Kits. Easy-On II Terminations

Size: px
Start display at page:

Download "JOSLYN. Underground Cable Accessories. Table of Contents. JPT/JIPT Polymer Terminations. ShrinkTite Sealing Kits. Easy-On II Terminations"

Transcription

1

2 Underground Cable Accessories JOSLYN Table of Contents JPT/JIPT Polymer Terminations 15kV, 25kV & 35kV ShrinkTite Sealing Kits 1kV In-Line Splice Sealing Kit Cable Jacket Sealing Kit Easy-On II Terminations 15kV through 35kV Class PSC Terminations 15kV through 46kV Class High Voltage Terminations Porcelain (Outdoor) 69kV & 138kV Polymer (Outdoor) 69kV & 138kV Gas Insulated Substation (GIS) 115kV UD-3 UD-8 UD-10 UD-16 UD-21 UD-2

3 JOSLYN Underground Cable Accessories Terminations, Polymer Outdoor (JPT) and Indoor (JIPT) Joslyn, a leader in distribution and transmission terminations since the 1960 s, offers a complete line of polymer terminations available for 15kV, 25/28kV and 35kV voltage applications. The outdoor JPT (with sheds) and indoor JIPT (without sheds) are a cold shrink-type polymer termination for easy, rapid and reliable installation. All Joslyn JPT and JIPT polymer terminations meet or exceed all requirements of IEEE Standard for Class 1 terminations and are RUS listed. The polymer termination shrinks on the cable as the inner core is pulled out of the termination. No complicated assembly, no heat guns or torches required, no struggling with cable while trying to slip on. Simply pull the core and let the termination shrink tight for a void-free termination and a superior seal with no hang-ups. Features: Silicone Polymer Housing Superior memory and weathering characteristics. Covers widest range of applications with fewest number of units. Three shed designs for superior weathering performance: Four sheds for 15kV outdoor model. Six sheds for 25/28kV outdoor model. Eight sheds for 35kV outdoor model. High dielectric constant material for stress relief. Easy visual indication of proper position. Pull down tabs for greater flexibility on jacketed concentric neutral cables. Silicone Polymer Housings The JPT and JIPT polymer terminations are manufactured using an optimized weathershed silicone formulation. The housing offers superior cable sealing and voltage withstand characteristics. Joslyn polymer terminations meet or exceed all requirements of IEEE Standard for Class 1 outdoor terminations. Unit tests include voltage withstand wet and dry, before and after load cycling on units installed on maximum conductor sized cable. Stress Relief The JPT and JIPT polymer terminations provide electric stress control for the cable by means of a flexible tube with a high permittivity dielectric constant. The stress relief tube is pre-assembled on the core under the polymer housing. As the core is removed, the stress relief tube and housing shrink onto the cable at the same time, in exactly the right position. No secondary operations are required during the installation. The electrical fields are refracted through the high dielectric constant tube and housing as shown. UD-3

4 Underground Cable Accessories JOSLYN Terminations, Polymer Outdoor (JPT) and Indoor (JIPT) (continued) Installation Standard cable preparation techniques are used for all JPT, Joslyn Polymer Terminations and JIPT, Joslyn Indoor Polymer Terminations. The Joslyn cold shrink terminations are assembled on a removable core. After the termination is inserted onto the prepared cable, the core is removed by pulling on the end. The housing then collapses onto the prepared cable. Memory of the material insures a void-free termination and a proper seal to prevent moisture ingress. The termination range is based on the cable insulation diameter. The minimum insulation diameter is the smallest cable size on which the termination will shrink onto and properly seal. The maximum insulation diameter is the largest cable size that will permit the core to be removed. Kit Contents Every JPT and JIPT comes complete with housing and stress tube pre-assembled on the core, ready for installation. Easy to read installation instructions will take you from cable preparation through installation. Every JPT and JIPT kit includes a handy cable preparation template to ensure proper cable cut-backs as shown. All kits include a tube of silicone grease, two plastic gloves and two strips of selffusing silicone tape. Jacketed Concentric Neutral (J) kits include mastic for sealing neutral wires, Concentric Neutral kits include a stainless steel wire tie for size 1 cable, and Metallic Type (M) kits include a grounding adapter for the metal tape. JPT Specifications and Catalog Numbers The JPT and JIPT termination design couples cold shrink technology and our pull down jacket seal features to provide a termination line that covers the widest range of applications with the fewest number of models. Just seven models cover 0.64 (16mm) to 2.10 (53mm) insulator diameter cables (#2 through 1250 kcmil). JPT 15kV Terminations Cable Range Joslyn Catalog No. Joslyn Catalog No. Joslyn Catalog No. (Primary O.D.) Jacketed Concentric Concentric Metallic Tape (Inches) Neutral Cable Neutral Cable Drain Wire Cable 0.64 to 1.12 JPT15J1 JPT15C1 JPT15M to 1.38 JPT15J2 JPT15C2 JPT15M to 2.10 JPT15J4 JPT15C4 JPT15M4 JPT 25/28kV Terminations Cable Range Joslyn Catalog No. Joslyn Catalog No. Joslyn Catalog No. (Primary O.D.) Jacketed Concentric Concentric Metallic Tape (Inches) Neutral Cable Neutral Cable Drain Wire Cable 0.84 to 1.38 JPT25J2 JPT25C2 JPT25M to 2.10 JPT25J4 JPT25C4 JPT25M4 UD-4

5 JOSLYN Underground Cable Accessories Terminations, Polymer Outdoor (JPT) and Indoor (JIPT) (continued) JPT 35kV Terminations Cable Range Joslyn Catalog No. Joslyn Catalog No. Joslyn Catalog No. (Primary O.D.) Jacketed Concentric Concentric Metallic Tape (Inches) Neutral Cable Neutral Cable Drain Wire Cable 0.84 to 1.38 JPT35J2 JPT35C2 JPT35M to 2.10 JPT35J4 JPT35C4 JPT35M4 JIPT 15kV Indoor Terminations Cable Range (Primary O.D.) Joslyn Catalog No. (Inches) 15kV Indoor 0.64 to 1.12 JIPT15J to 1.38 JIPT15J to 2.10 JIPT15J4 Indoor Type JPT15 JPT25 JPT35 JIPT15 Sizes Available* 1,2,4 2,4 2,4 1,2,4 Voltage Rating (kv) 15 25/ Number of Sheds Minimum Strike Distance (In.) [mm] 11.6 [295] 14.5 [368] 16.8 [427] 8.4 [213] Creepage Distance (In.) [mm] 15.0 [381] 22.8 [578] 30 [762] 8.4 [213] Max. Design Voltage to Ground (kv) Corona Extinction Voltage (kv) [ 3 pc.] (Partial Discharge) Insulation Withstand Voltage: Lightning Impulse (BIL) Dry Withstand (kv Crest) Sec. Wet (60 Hz) (kv) Minute Dry (60 Hz) (kv) Hour Dry (60 Hz) (kv) DC Withstand 15 Min. Dry (kv) *Sizes (cable insulation diameter ranges): 1= [16-28 mm]; 2= [21-35 mm]; 4= [33-53 mm]. UD-5

6 Underground Cable Accessories JOSLYN Terminations, Polymer Outdoor (JPT) and Indoor (JIPT) (continued) JPT Termination Accessories Connector Options Joslyn has the most complete offering of connector options for polymer terminations. Catalog Code Designator A All aluminum, tin plated compression connector used on aluminum or copper conductors under normal service conditions. (#4 through 4/0 [ mm 2 ]) B Friction welded copper pin to an aluminum compression barrel. Ideal for a hostile environment and/or when the terminated cable is aluminum and connects to an overhead copper conductor. Only the copper portion of the connector is exposed to the elements. (#4 through 4/0 [ mm 2 ]) C All copper compression connector used on copper conductors. (#4 through 4/0 [ mm 2 ]) E A bi-metal connector with a threaded copper top and eyebolt connector. Ideal when the versatility of an eyebolt is required for drop wire connection. (34 through 4/0 [ mm 2 ]) H One hole spade, tinned aluminum connector (1/0 through 750 kcmil [ mm 2 ]) P Two hole NEMA spade, tinned aluminum connector. NEMA spaced holes permit side by side mounting on 4-hole spades. The preferred connector for larger conductor sizes. Spade connectors are available for higher voltage and current applications. (#4 through 1250 kcmil [ mm 2 ]) S The most commonly used connector. A bendable copper wire lead with a tin plated aluminum barrel. The stem or wire lead connector offers the advantage of soft drawn copper allowing the stem to be easily bent or trained to make a connection to the line or fuse cutout. (#2 through 4/0 [ mm 2 ]) Contact your local Joslyn Sales Representative for special requirements. Cable Mounting Brackets Joslyn Catalog No. JB-1 JB-2 JB-3 Cable Range (Primary O.D.) (20-32 mm) (28-38 mm) (37-50 mm) UD-6

7 JOSLYN Underground Cable Accessories ORDERING INFORMATION Use the model to develop the catalog number for your application. Contact your local Joslyn Sales Representative for special requirements. TO ORDER TERMINATION ONLY: TO ORDER WITH CONNECTOR: add dash (-) and codes below Outdoor JPT J I P T } kv Rating Cable Type Insulation Range Connector Type Conductor Code Indoor C J M (21 mm-35 mm) (15 kv, 25 kv, 35 kv) (33 mm-53 mm) (15 kv, 25 kv, 35 kv) Concentric Neutral (16 mm-28 mm) (15 kv only) Jacketed Concentric Metallic Tape A B C H E P S Tinned Aluminum #4-4/0 Bi-Metallic #4-4/0 Copper #4-4/0 Spade 1-hole I/O-750 kcmil Eye Bolt #4-350 kcmil Spade 2-hole # kcmil Wire Lead #2-4/0 Conductor Size* Code #4 AWG 004 1/0 AWG 1/0 500 kcmil kcmil 125 D S C Solid Stranded or Compressed Compact Round Sample Catalog Number JPT15J1 (termination only) Outdoor termination for 15kV jacketed concentric neutral cable with insulation O.D to 1.12 [16 mm to 28 mm] JPT15J1-S002S (with connector) same as above plus wire lead conector for #2 AWG stranded conductor (omit S002S if connector is not required) TO ORDER CONNNECTORS SEPARATELY JC- Connectors can be ordered separately in multiples of 24 per carton. Example: An order for 24 JC-S002S will contain a carton of 24 wire lead connectors for use on a #2 AWG stranded conductor. * Note: All conductor sizes in the range #4 through1250 kcmil are available. UD-7

8 Underground Cable Accessories JOSLYN ShrinkTite 1kV In-Line Splice Sealing Kits 1 Joslyn In-Line Splices are a cold shrink-type product that features: Easy, Time-Saving Installation. Requires no heat, special tools or training. Water Resistance. Provides moisturetight seal and meets requirements of ANSI C119.1 and Western Underground Guide 2.14 for secondary splices rated up to 1kV. UV Resistance: Ideal for outdoor applications ensuring long-term performance. Specifications and Ordering Information for 1kV Joslyn In-Line Splice Sealing Kits Min. Cable Max. Dia. Max. Std. Pkg.* O.D. for Insulator Connector Relaxed (Pcs. Per Catalog No. Conductor Size Seal Cover Length Tube Length Box) JCLS AWG (14-16mm 2 ) (7.8mm) (4.3mm) (51mm) (152mm) JCLS /0 AWG (35-50mm 2 ) (10.1mm) (20.9mm) (76mm) (203mm) JCLS3-11 2/0 AWG-250 kcmil (70-125mm 2 ) (13mm) (29.9mm) (178mm) (279.4mm) JCLS kcmil ( mm 2 ) (188mm) (33mm) (203mm) (305mm) JCLS kcmil ( mm 2 ) (188mm) (33mm) (305mm) (406.4mm) JCLS kcmil ( mm 2 ) (24mm) (48mm) (203mm) (305mm) JCLS kcmil ( mm 2 ) (24mm) (48mm) (356mm) (457mm) JCLS kcmil ( mm 2 ) (32.2mm) (67.8mm) (203mm) (305mm) JCLS kcmil (500mm 2 ) (32.2mm) (67.8mm) (356mm) (457mm) JCLS kcmil ( mm 2 ) (42.6mm) (93.7mm) 356mm) (457mm) *Each unit sealed in a poly bag. UD-8

9 JOSLYN Underground Cable Accessories ShrinkTite Cable Jacket Sealing Kit Joslyn Jacket Sealing Kits are a cold shrink-type product designed to seal the end of jacketed cables. Use these kits when installing elbows or other cable accessories that do not include a jacket seal. Like the Joslyn In-Line Splice products, the Cable Jacket Sealing Kits offer these important features: Easy, Time Saving Installation Water Resistance UV Resistance Cable Jacket Sealing Kits for Jacketed Cables Catalog No. JRS5-6 JRS6-8 JRS7-8 Max. Cable O.D. for Seal Max. Cable O.D. for Seal kV Cable 2-4/0 2/ kcmil kcmil 25kV Cable 2-2/0 1/0-750 kcmil kcmil 35kV Cable 1/0 1/0-500 kcmil kcmil Kit Components Sealing Tube Mastic Strips 6 3 Strips 4 Strips 6 Strips Instruction Std. Pkg./Pcs. Per Box UD-9

10 Underground Cable Accessories JOSLYN Easy-On II Terminations 15kV through 35kV Class The Easy-On II termination is used on jacketed concentric neutral, metal tape shielded or wire shielded cables without need for additional kits or tapes. The termination ground (or neutral) connection has the same ampacity as the cable shield (neutral system. The Easy-On II terminations E5200, E5202 and E5203 are light enough to hang from a fuse cutout. A full line of connectors is available for Easy-On II terminations for conductor sizes 6 AWG through 1000 KCM. Connector types include: pin type, 6 inch copper wire lead, eyebolt, in-line sleeve, aerial, flat bus and spade. Mounting Instructions Joslyn provides termination mounting brackets for structures, poles and crossarms. Brackets are galvanized steel and meet all NEMA and applicable ASTM standards. Detailed dimensional data is available in the Joslyn catalog section PH Brackets. The Easy-On II termination meets all industry requirements and is a Class I (outdoor) termination as defined in IEEE 48 standard for high voltage terminations. It contains a porcelain insulator and a factory-made elastomer stress relief for use on all synthetic insulated solid dielectric cables. The stress control elastomer is installed within the porcelain at the factory. Sizes are available for all shielded cables in voltage classes from 2kV through 34.5kV and conductor sizes through 1000 KCM. Product Features The porcelain insulator has maximum resistance to moisture, industrial pollution and seacoast pollution. Porcelain is the most reliable insulator for use where insulator dry-band arcing may occur. The termination interior dielectric system is the Joslyn patented spring loaded elastomer system. The spring force on the elastomer produces a strong dielectric interface along the cable and the porcelain bore; it prevents the ingress of water, and it accommodates the thermal expansion and contraction of the cable. The Joslyn patented elastomer spring load system is the most reliable method to provide continuous mechanical force to the elastomer, thereby negating any elastomer permanent set. The termination interior dielectric system contains a conductive elastomer stress relief cone. All of the termination interior elastomer dielectric parts are factory assembled. Termination field assembly is as easy as pulling the two pins releasing the elastomer compression spring. No tapes, tubes, nuts or bolts. No pushing or pulling or shrinking to fit. UD-10

11 JOSLYN Underground Cable Accessories Easy-On II Terminations 15kV through 35kV Class (continued) Connectors All Easy-On II terminations require a connector. They not only make the connection to the shielded underground cable, but they also are a part of the sealing system. Aluminum connectors are not recommended in corrosive environments or when a copper aerial drop wire is used. All compression connectors along with the applicable aerial connections (parallel groove, eyebolt, aerial and flat pad) meet all industry standards such as EEI TD-160 and ANSI/NEMA CC All the aluminum connectors are tin plated. The aerial connections are either tin plated aluminum or copper alloy. The following are the connectors used on the Easy-On II termination. E5200, E5202, E5203 Connectors for E5200, E5202 & E5203 PIN TYPE CONNECTOR WITH OR WITHOUT PARALLEL GROOVE CONNECTOR Connector Conductor Range Connector Materials Parallel Groove Connector Materials Code Tin-Plated Aluminum Tin-Plated Aluminum TG-1 Without Parallel Groove Connector NO-1 6 Str. through 300 Compact Copper Tin Plated Aluminum TG-C Bronze PG-C Without Parallel Groove Connector NO-C 3 Str. through 3/0 Compact Bi-Metallic Aluminum Bronze PG-3 Barrel with Copper Pin Without Parallel Groove Connector NO-3 EYEBOLT CONNECTOR Connector Conductor Range Connector Materials Code 2 Str. through 3/0 C.R. Tin-Plated Aluminum and Tin-Plated Bronze Eyebolt ES-1 2 Str. through 3/0 C.R. Copper Top Pin & Tin-Plated Bronze Eyebolt ES-3 WIRE LEAD CONNECTOR Connector Conductor Range Connector Materials Code 4 Str. through 2/0 Sol. Tin-Plated Barrel and Tin-Plated Copper Stem WL-1 SLEEVE CONNECTOR Connector Conductor Range Connector Materials Code 4 Str. through 2/0 Sol. Tin-Plated Aluminum CS-1 UD-11

12 Underground Cable Accessories JOSLYN Easy-On II Terminations 15kV through 35kV Class (continued) Physical Data Max. Voltage Bil Catalog Conductor Insulator Dry Arc Wet Leak Height Dia. Wt. Class (kv) Number Range Range Dist. (In.) Dist. (In.) (In.) (In.) (Lbs.) 15kV 110 E E5260 4/ kV 150 E E5265 4/ kV 200 E / E5263 4/ Notes: All dimensions are in inches. Conductor sizes are AWG and KCM. Termination height excludes additional connectors such as the aerial connector or the flat pad bus connector. Height does include pin connector such as TG-1 on the small Easy-On. Field Assembly Each Joslyn termination is complete with field assembly instructions. Only normal hand tools are required. The following is a summary of the field assembly. UD-12

13 JOSLYN Underground Cable Accessories Easy-On II Terminations 15kV through 35kV Class (continued) Catalog Number Selection The Easy-On termination is available in two size series for each voltage class, 15 through 34.5kV. The first is the E5200 series which uses small diameter porcelains for conductor sizes through 250 KCM. The second is the E5260 series which uses large diameter porcelains for conductor sizes through 1000 KCM. Fill the blanks in the catalog number with the proper codes for voltage, conductor, connector and mounting or grounding option. UD-13

14 Underground Cable Accessories JOSLYN Easy-On II Terminations 15kV through 35kV Class (continued) UD-14

15 JOSLYN Underground Cable Accessories Easy-On II Terminations 15kV through 35kV Class (continued) UD-15

16 Underground Cable Accessories JOSLYN PSC Terminations 15kV through 46kV Class The Joslyn PSC (Preformed Stress Control) termination meets all industry requirements and is a Class 1 (outdoor) termination as defined in IEEE 48 standard for high voltage terminations. It contains a porcelain insulator and factorymade elastomer stress relief for use on all synthetic solid dielectric cables. Sizes are available for all shielded cables in voltage classes from 2kV through 46kV and conductor sizes through 2000 KCM. Product Features The porcelain insulator has maximum resistance to moisture, industrial pollution and seacoast pollution. Porcelain is the most reliable insulator for use where insulator dryband arcing may occur. The brass top cap has maximum resistance to industrial and seacoast pollution. O-rings seal the top cap to the porcelain. This is the most reliable and proven seal available in the industry. Connectors are available for aluminum and copper conductor cables. The external connection to the overhead system may be made with a Joslyn eyebolt, aerial or spade termination connector. All the aluminum lower castings are Almag 35, the most corrosion resistant aluminum alloy available. The termination lower casting makes the cable shield ground connection with no extra parts, straps or soldering. The electric stress control cone is a factory made soft elastomer which also seals the cable shield to environmental moisture. The Joslyn patented, spring-loaded elastomer filler is the most reliable factory made dielectric system available. The resulting dielectric interfaces have high dielectric strength, prevent ingress of moisture and accommodates the thermal expansion and contraction of the cable. The Joslyn patented spring loaded elastomer system is the most reliable method to provide continuous mechanical force to the elastomer, thereby compensating for elastomer permanent set. UD-16

17 JOSLYN Underground Cable Accessories PSC Terminations 15kV through 46kV Class (continued) Mounting Bracket Applications Joslyn provides termination mounting brackets for structures, poles and crossarms. Brackets are galvanized steel and meet all NEMA and applicable ASTM standards. For dimensions, see Brackets section of Pole Line Hardware catalog. Connectors Eyebolt Top Cap All PSC terminations require a connector to make the contact from the cable conductor to the bare overhead system. Those terminations having an eyebolt top (2-2/0) use a pin-type connector. This connector is available in copper, aluminum or bi-metal styles. The pin accommodates conductor 6 through 2/0. The eyebolt accommodates conductors 2 through 2/0. UD-17

18 Underground Cable Accessories JOSLYN PSC Terminations 15kV through 46kV Class (continued) Connectors Threaded Stud Top Cap Aerial or flat pad bus connectors are available for conductor sizes 2 through 2000 KCM. Lug Fits Thread Lug Lug Approx. Number Approx. Threaded Size of Lug Min. Max. Net Lug Of Hole Net Stud On kv Lug and Catalog Wire Wire Weight Catalog Bolt Diameter Weight Terminal Rating Terminal Number (AWG) (KCM) (Lbs.) Number Holes (Inches) (Lbs.) J9280-2/ / Solid / P 6 Solid P 2 9/16.50 J9280-3/ Solid / P 2 Solid P 2 9/ P 4 9/16 2 J9280-4/ / /0 Str / J9283-2/ / Solid /16 1 J9283-3/ Solid / P 2 Solid P 2 9/ P 4 9/16 2 J9284-2/ / Solid / P 2 Solid P 2 9/16.50 J9284-3/ Solid / P 2 Solid P 2 9/ P 4 9/16 2 J / /0 Str / J Solid / P 2 Solid P 2 9/ P 4 9/16 2 Material: High Conductivity Electrical Bronze with High Tensile Silicon Bronze Hardware or Tin Plated Aluminum as illustrated above. For Tin Plated Bronze, use above number followed by /87D. Field Assembly Each Joslyn termination is complete with field assembly instructions. Only normal hand tools are required. The following is a summary of the field assembly. UD-18

19 JOSLYN Underground Cable Accessories PSC Terminations 15kV through 46kV Class (continued) Physical Data Bracket Mounted Terminations Max. & Min. Cable Cable Porcelain Porcelain Conductor Insul. Dry Arc Leakage Porcelain Overall Max. Top BIL (AWG or O.D. Distance Distance Diameter Height Height Dia. Weight Cap Catalog Number (kv) KCM) (In.) (In.) (In.) (In.) (In.) (In.) (In.) (Lbs.) Connection J9280/ / Eyebolt J9280-2/ Threaded Stud J9280-3/ Threaded Stud J9280-4/ Threaded Stud J / / Eyebolt J9283-2/ Threaded Stud J9283-3/ Threaded Stud J9284-2/ Threaded Stud J9284-3/ Threaded Stud J Threaded Stud J Threaded Stud SIX BOLT MOUNTING ON 6-5/8 BOLT HOLE CIRCLE UD-19

20 Underground Cable Accessories JOSLYN PSC Terminations 15kV through 46kV Class (continued) Catalog Number Selection The Joslyn PSC termination consists of three basic components: the external connector which connects to the bare overhead system; the porcelain housing; the elastomer kit which contains the elastomer insulator, stress cone and the compression Bracket Mounted Terminations External ConnectorJoslyn Elastomer Kit Flat Pad Joslyn PSC Compression Insulation Cable Termination Aerial Bus Porcelain Connector Type Voltage BIL Conductor Eye Bolt Connector Catalog Termination (Within Class (kv) Range Connection Catalog No. No. Housing Housing) Kit No. 15kV /0 AWG YES NO NO J9280/78 COPPER 80 C J BI-METALLIC 80 C R ALUMINUM 80 C Y 15kV AWG-500 KCM NO J9280-2/78 COPPER 80 C L P P BI-METALLIC 80 C U 15kV KCM NO J9280-3/78 COPPER 80 C P P P P BI-METALLIC 80 C V 15kV KCM NO J9280-4/78 COPPER 80 C M (4/0-2000) BI-METALLIC 80 C W 25kV /0 AWG YES NO NO J /78 COPPER 83 C H BI-METALLIC 83 C S ALUMINUM 83 C Z 25kV AWG-500 KCM NO J9283-2/78 COPPER 83 C L P P BI-METALLIC 83 C U 25kV KCM NO J9283-3/78 COPPER 83 C P P P P BI-METALLIC 83 C V 19.9/34.5kV /0 AWG YES NO NO J /78 COPPER 83 C H BI-METALLIC 83 C S ALUMINUM 83 C Z 34.5kV AWG-500 KCM NO J9284-2/78 COPPER 84 C L P P BI-METALLIC 84 C U 34.5kV KCM NO J9284-3/78 COPPER 84 C P P P P BI-METALLIC 84 C V 34.5kV KCM NO J COPPER 84 C M (4/0-2000) BI-METALLIC 84 C W 46kV KCM NO J COPPER 85 C P P P P BI-METALLIC 85 C V Note: All conductor sizes in the range 6 AWG through 2000 KCM are available. External connectors with P suffix are tin plated aluminum. All others are bronze. See chart on page UD-18. Semicon and/or EXAMPLE: 25kV, 4/0 Aluminum Conductor Cable, Jacket Diameter in Concentric Neutral Construction Inches (2 Decimal Places) Times 100 Cable Insulation Diameter 1.11 in. Insulator Diameter in Semicon Diameter 1.20 in. Inches (2 Decimal Places) Times 100 External Connector Termination Housing Joslyn PSC Elastomer Kit J9283-2/ C 111 U 120 Conductor Size Code Conductor Semicon and/or Jacket Diameter Insulation O.D. Contact Joslyn for modifications for special applications and different conductor conditions. connector. The compression connector attaches the underground cable to the top cap or the aerial connector (page UD-12). To determine the three order numbers, start with the voltage rating and read the chart from left to right. Wire Size 6 1 1/0 4/ Code All wire sizes available For solid conductor add /83 For compact round conductor add /83A For metallic tape grounding coil, contact Joslyn UD-20

21 JOSLYN Underground Cable Accessories Terminations, High Voltage, Porcelain and Polymer 1 With over 20,000 installations worldwide, the Joslyn Preferred Stress Control Elastomer has been shown to provide up to 40 years of reliable service life. The Joslyn 69 and 138 kv terminations meet or exceed the requirements of the applicable IEEE-48 standard for Class 1 Terminations. FEATURES: SPRING-LOADED ELASTOMER STRESS CONE: Provides stress relief at the cable semi-conducting insulation shield and a permanent elastomeric seal at the termination base. Spring pressure on the stress-cone compensates for the expansion and contraction over a wide temperature range, assuring a void-free interface under severe climatic conditions. SOLID/LIQUID DIELECTRIC SYSTEMS: The excellent heat transfer characteristics provide a termination that does not limit the current rating of the cable. The current carrying capacity of the terminator is equal to that of the cable. FAST, EASY INSTALLATION: Unit is pre-assembled. Taping and special tools are not required. Cable cut back dimensions do not vary and are the same for each cable. FIELD MAINTENANCE: No field maintenance, beyond periodic cleaning, is required. If cable replacement is required, the termination housing can be retrofit with the new termination kit at the installation site. REGISTERED SERIAL NUMBERS: Each termination is identified with a serial number. The customer names and cable characteristics are recorded by serial number. UD-21

22 Underground Cable Accessories JOSLYN Terminations, High Voltage, Porcelain and Polymer (continued) 1 High Voltage Outdoor Porcelain Terminations Joslyn high voltage porcelain terminations feature the combination of a wet process, electrical grade porcelain housing and a spring loaded, solid/liquid dielectric system providing a long-term, dependable termination. Catalog No. J J J9286-4/94L J J Rated Voltage: ANSI kv Rated Voltage: IEC kv BIL kv Max. Conductor Size KCM/mm / / / / /1250 Max. Insulation O.D. in/mm 2.8/71 2.9/ / / /88 Min. Insulation O.D. in/mm 1.3/33 1.3/33 2.8/ / /60 Max. Insulation Shield O.D. in/mm 3.3/84 3.3/84 3.6/92 4.5/ /114 Std. Leakage Distance in/mm 70/ / / / /3302 Extra Leakage Distance in/mm 90.5/ / / / /4572 Dry Arcing Distance in/mm 27/686 27/686 27/686 58/ /1473 Cantilever Strength ft-lb/knm 5260/ / / / /17.2 Stud Length (H) in/mm 2-7/8 / /8 / /8 / /8 / /8 / 86 Stud Size (S) in / / /2-12 Approximate Weight lbs/kg 150/68 150/68 150/68 500/ /227 UD-22

23 JOSLYN Underground Cable Accessories Terminations, High Voltage, Porcelain and Polymer (continued) LiteTerm High Voltage Polymer Terminations LiteTerm Polymer Cable Terminations combine time-tested stress relief components with the latest in silicone outdoor bushing technology. With over 20,000 installations worldwide, the Joslyn Preformed Stress Control Elastomer has been shown to provide up to 40 years of reliable service life. Now matched with silicone polymer housings the leading technology for high-voltage bushings our new LiteTerm polymer cable terminations makes for lightweight, easy-tohandle installations and reliable, long-term performance. Features: HTV Composite Silicone Polymer, directly molded over lightweight spun fiber reinforced tube. Superior track resistance and weathering properties. Extremely lightweight Installation ease, no special tools required Catalog No. P P P P Rated Voltage: ANSI kv Rated Voltage: IEC kv BIL kv Max. Conductor Size KCM/mm / / / /1250 Max. Insulation O.D. in/mm 3.35/ / / /96 Min. Insulation O.D. in/mm 1.3/33 1.3/ / /60 Max. Insulation Shield O.D. in/mm 3.6/92 3.6/92 4.5/ /114 Std. Leakage Distance in/mm 87/ / / /5538 Dry Arcing Distance in/mm 27/686 27/686 63/ /1600 Stud Length (H) in/mm 2-7/8 / /8 / /8 / /8 / 86 Stud Size (S ) in / /2-12 Approximate Weight lbs/kg 85/38 85/38 195/79 195/79 SPRING PRESSURE PLATE "O" RING GASKET (EPD M) SPRING GUIDE ROD COMPRESSION CONNECTOR "O" RING GASKET BRASS COVER SUPPORT ROD COMPRESSION SPRING "O" RING GASKET OIL LEVEL SILICONE FLUID B A A B STUD SIZE COMPRESSION CONNECTOR "O" RING GASKET COMPRESSION SPRING "O" RING GASKET INSULATOR TUBES SILICONE FLUID FIGURE A FIGURE B SILICONE HOUSING INSULATOR TUBES SILICONE HOUSING 78" (1982 m m ) 36" (914 mm) SILICONE FLUID SUPPORT WASHER PHENOLIC SUPPORT RING STRESS CONE ASSEMBLY INSULATING ELASTOMER CONDUCTIVE ELASTOMER STRESS CONE { INSULATING ELASTOMER CONDUCTIVE ELASTOMER MOUNTING SURFACE HIGH CORROSSION RESISTANCE AL ALLOY BASE BOTTOM COVER PLATE ALUMINUM ALLOY SIX (6) 15mm DIA. HOLES ON 305m m B.C. REQUIRED FOR MOUNTING NEOPRENE GASKET MOUNTING PLATE WIPING SLEEVE WIPING SLEEVE SIX (6) 9/16" (14 mm) DIA HOLES ON 7 1/2" (191 mm) DIA. B.C. REQUIRED FOR MOUNTING 14.25" (361 m m ) DIA Pb JACKET UD-23

24 Underground Cable Accessories JOSLYN Terminations, High Voltage, Porcelain and Polymer (continued) ACCESSORIES High Voltage Outdoor Terminations /87D 86-33/87D Lugs For Cu or Al Bare Wire Aerial Connection /87D 86-34/87D J Series & J Series J Series & J Series Terminal P Series & P Series P Series & P Series Catalog No /87D 86-33/87D Conductor Range #2 Sol. AWG-1000 KCM (30mm 2-500mm 2 ) 4/0 Str KCM (100 mm mm 2 ) Material High Conductivity Tin Plated Copper Alloy Lugs For Cu or Al Bus Bar Connection J Series & J Series J Series & J Series Terminal P Series & P Series P Series & P Series Catalog No /87D 86-34/87D No. of Bolt Holes Four (4) NEMA Pad Four (4) NEMA Pad Hole Diameter 9/16 inches (14mm) 9/16 inches (14mm) Hole Center to Center Distance 1-3/4 inches (45mm) 1-3/4 inches (45mm) Material High Conductivity Tin Plated Copper Alloy UD-24

25 JOSLYN Underground Cable Accessories Terminations, High Voltage, Porcelain and Polymer (continued) J9201-VA J9201-V Mounting Plates and Brackets J & J J & J Use with Terminal P & P P & P Catalog No. Plate/Bracket Plate Catalog No. J9201-V J9201-VA J9201-V Material Hot Dip Galvanized Steel J9201-VA UD-25

26 Underground Cable Accessories JOSLYN Terminations, Cable, GIS 115kV for Extruded Solid Dielectric Insulated Cables The increased demand of electrical power and lack of space in highly populated urban areas has created a need for compact gas insulated substations and switching centers. The connection of these centers to the underground electrical network must be very reliable since the system s dielectric integrity depends on the cable terminals used to make this connection. Combining new technologies with the experience gained in over 30 years as a pioneer in the design and manufacture of accessories to terminate solid dielectric insulated cables, Joslyn has designed a terminal which meets the strict electromechanical requirements for connecting the high voltage cables to the gas insulated switchgear. Features Joslyn cable terminations for high voltage SF6 insulated metal enclosed switchgear are designed to terminate 115kV solid dielectric cables with Al or Cu conductors up to 1200 mm 2. Joslyn terminations meet all the dimensional requirements of IEC 859 standard. Track resistant epoxy resin insulator. Pressure tested (water filled) to 36 bars. All electrical contact points are silver (Ag) plated. All metal parts in contact with SF6 are made of Cu alloys or stainless steel. One piece pre-assembled design eliminates on-site assembly error for fast and easy installation. No special tools required. Preformed geometric stress relief eliminates critical and time consuming manual taping. Spring loaded elastomeric sealing system for a highly reliable non thermally sensitive seal. Horizontal installation available. Construction Characteristics Applicable Standards: IEEE , IEC 859 Non-flammable Insulating Silicone Oil Filled Silver (Ag) plated compression connectors. For cables with Al conductor, an inertia welded silver (Ag) plated Al-Cu bi-metallic connector is supplied. The current carrying capability of the compression connector is equal or greater than the cable conductor. Maximum Conductor Size Cu or Al: 1200 mm 2 Maximum Diameter Over Cable Insulation: 87.0 mm Maximum Internal Pressure at 90 C: Mpa UD-26

27 JOSLYN Underground Cable Accessories M10 THREAD 4 PLACES 90 APART (3.15) B.C O.D (4.33) I.D (3.98) TOP VIEW OF CONTACT PAD Connector Filler Port Vent Port Contact Pad Corona Shield 757 (29.80) VENT PLUG EXPANSION RESERVOIR OPTIONAL FOR HORIZONTAL MOUNTING O Ring Gaskets Filler Spring Loaded Sealing System Epoxy Housing Stress Cone Grounding Housing Silicone Oil (12.0) 215 (8.46) (9.8) (2.0) (7.75) (7.75) (7.0) 115kV GIS TERMINATION Wiping Sleeve (Optional) UD-27

28 Underground Cable Accessories JOSLYN Terminations, Cable, Ordering Information J - Porcelain P - Polymer The following information details the GIS termination catalog numbering system: kv Rating Conductor Size Type of Conductor Dia. Over the Cable Insulation Model No. Dia. Over Insulation Shield (Semi-Con) Options NOTE: Use I for Metric Measurements Use U for U.S. Standard Measurements I =mm 2 U = KCM CR = Compact Round ST = Stranded SG = Segmented I =mm* U = in I =mm* U = in WS = Wiping Sleeve GH = Grounding Housing ST = Shrink Tube HM = Horizontal Mounting Conductor Material C = Copper A = Aluminum *If insulation diameter is 100mm or greater, use 3-digit field. Required information to order terminations: Conductor: Please check the box that applies. Size: mm 2 OR KCM Material: Al OR Cu Diameter: mm OR in Diameter over the cable insulation: mm OR in Diameter over insulation shield: mm OR in (semi-con O.D.) EXAMPLE: 800mm 2 compact round copper conductor Diameter over the cable insulation = 94mm Diameter over the insulation shield (semi-con) = 97mm CATALOG NO. = GIS CRC94A97 Type of electrostatic shield: UD-28

Easy-On II Terminations

Easy-On II Terminations Features Class 1 (outdoor) termination as defined in IEEE 48 standard. For use on all extruded dielectric cables, concentric neutral, metal tape shielded or wire shielded cables without need for additional

More information

PSC Terminations. Features Class 1 (outdoor) termination as defined in IEEE 48 standard. For use on all extruded dielectric cables.

PSC Terminations. Features Class 1 (outdoor) termination as defined in IEEE 48 standard. For use on all extruded dielectric cables. Features Class 1 (outdoor) termination as defined in IEEE 48 standard. For use on all extruded dielectric cables. Sizes are available for all shielded cables in voltage classes from 15kV through 46kV.

More information

Quick Splice II. 35 kv Molded Rubber Inline Splicing Kit Data Sheet. 2. Applications. 1. Product Description

Quick Splice II. 35 kv Molded Rubber Inline Splicing Kit Data Sheet. 2. Applications. 1. Product Description Quick Splice II 5461 (CN) Cable (JCN) Cable 35 kv Molded Rubber Inline Splicing Kit Data Sheet Accessory Splice Jacket 1. Product Description The 3M 5461 Quick Splice II is a 35 kv class inline splice

More information

Quick Splice II 5451R. 25/28 kv Molded Rubber Cable Repair Splicing Kit Data Sheet. 1. Product Description. 2. Applications

Quick Splice II 5451R. 25/28 kv Molded Rubber Cable Repair Splicing Kit Data Sheet. 1. Product Description. 2. Applications Quick Splice II 5451R (CN) Cable (JCN) Cable Accessory Splice Jacket 25/28 kv Molded Rubber Cable Repair Splicing Kit Data Sheet 1. Product Description The 3M 5451R Quick Splice II is a 25/28 kv class

More information

Terminations. 3M Cold Shrink Terminations FAX TERMINATIONS. Glossary of Terminations Terms 263 Cable Types for Terminating 264 3M

Terminations. 3M Cold Shrink Terminations FAX TERMINATIONS. Glossary of Terminations Terms 263 Cable Types for Terminating 264 3M Terminations Glossary of Terminations Terms 263 Cable Types for Terminating 264 3M Cold Shrink QT-III Silicone Rubber Terminations 265 3M Cold Shrink Termination QT-III 69 kv/72,5 kv 270 3M Cold Shrink

More information

Loadbreak Elbows. 3 Loadbreak Elbows. 200 Amp 5-15 kv Industrial pg Loadbreak Elbows. 200 Amp 25 kv Industrial pg. 254.

Loadbreak Elbows. 3 Loadbreak Elbows. 200 Amp 5-15 kv Industrial pg Loadbreak Elbows. 200 Amp 25 kv Industrial pg. 254. 3 Loadbreak Elbows 200 Amp 5-15 kv Industrial pg. 252 Loadbreak Elbows 200 Amp 25 kv Industrial pg. 254 Loadbreak Elbows 200 Amp Industrial pg. 255 Loadbreak Elbows Accessories 3 Loadbreak Elbows 3M 200

More information

Loadbreak Apparatus Connectors

Loadbreak Apparatus Connectors Loadbreak Apparatus Connectors 200 A 25 kv Class POSI-BREAK Loadbreak Elbow Connector with Optional Integral Jacket Seal* Electrical Apparatus 500-29-7 general The POSI-BREAK Loadbreak Elbow Connector

More information

35-kV Thru-Bushings F Series (bolt-in) for Air-Insulated to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

35-kV Thru-Bushings F Series (bolt-in) for Air-Insulated to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp Page 1 2018 Equipment Connection Bus Bar, or Grounded Metal Equipment Plate F Series Mounting Holes ELRIM Cycloaliphatic Epoxy Provides: Nontracking, self-scouring, nonweathering performance Superior dielectric

More information

15 kv and 25 kv Thru-Bushings

15 kv and 25 kv Thru-Bushings Page 1 2001 ELRIM Cycloaliphatic Epoxy Provides: Nontracking, self-scouring, nonweathering performance Superior dielectric strength, dielectric loss and power factor Choice of shapes allows design innovation

More information

3M Cold Shrink QT-III Silicone Rubber Termination Kits 7640-T and 7650-T Series 5, 8, 15, 25/28 and 35 kv

3M Cold Shrink QT-III Silicone Rubber Termination Kits 7640-T and 7650-T Series 5, 8, 15, 25/28 and 35 kv 3M Cold Shrink QT-III Silicone Rubber Termination Kits 7640-T and 7650-T Series 5, 8, 15, 25/28 and 35 kv Data Sheet September 2014 Description 3M Cold Shrink QT-III Silicone Rubber Termination Kits, 7640-T

More information

High Voltage Joints and Terminations up to 72,5 kv 145 kv

High Voltage Joints and Terminations up to 72,5 kv 145 kv High Voltage Joints and Terminations up to 72,5 kv 145 kv 3M Cold Shrink Termination Kits QT-III and Joint Kits are designed to provide high reliability and save you time and money. They install quickly

More information

Loadbreak Apparatus Connectors. 200 A 15 kv Class Loadbreak Elbow Connector with Optional Integral Jacket Seal GENERAL

Loadbreak Apparatus Connectors. 200 A 15 kv Class Loadbreak Elbow Connector with Optional Integral Jacket Seal GENERAL Loadbreak Apparatus Connectors 200 A 15 kv Class Loadbreak Elbow Connector with Optional Integral Jacket Seal Electrical Apparatus 500-10-7 GENERAL The Cooper Power Systems Loadbreak Elbow Connector is

More information

200 A 25 and 28 kv class POSI-BREAK loadbreak elbow connector with optional integral jacket seal-canadian Edition

200 A 25 and 28 kv class POSI-BREAK loadbreak elbow connector with optional integral jacket seal-canadian Edition Loadbreak Connectors CA650101EN Supersedes 500-29-7C November 2011 COOPER POWER SERIES 200 A 25 and 28 kv class POSI-BREAK loadbreak elbow connector with optional integral jacket seal-canadian Edition

More information

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp Page 1 2018 Grounded Metal Equipment Plate Equipment Connection Bus Bar or Other Component 15 kv or 25 kv Separable Insulated Connector (elbow) Equipment Connection Power Cable Power Cable ELRIM Cycloaliphatic

More information

Type M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary

Type M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary 14B-2 Type M3 Hookstick Disconnect Switches Up to 38kV 0 or 900 Amp 40kA Momentary Application The Chance Type M3 Disconnect Switch is a single-phase hookstick operated switch. It is for manual switching

More information

25-kV Apparatus Bushings A Series (clamp-in) for Elbow to Air-Insulated Service 200 Amp and 600 Amp

25-kV Apparatus Bushings A Series (clamp-in) for Elbow to Air-Insulated Service 200 Amp and 600 Amp Page 1 2018 Grounded Metal Equipment Plate Equipment Connection 15 kv or 25 kv Separable Insulated Connector (elbow) Grounded Metal Equipment Plate Equipment Connection Power Cable Power Cable ELRIM Cycloaliphatic

More information

25 kv Apparatus Bushings

25 kv Apparatus Bushings Page 1 2001 ELRIM Cycloaliphatic Epoxy Provides: Nontracking, self-scouring, nonweathering performance Superior dielectric strength, dielectric loss and power factor Choice of shapes allows design innovation

More information

Deadbreak Apparatus. connectors. 600 A 15/25 kv Class GENERAL

Deadbreak Apparatus. connectors. 600 A 15/25 kv Class GENERAL Deadbreak Apparatus Connectors 600 A 15/25 kv Class BOL-T Deadbreak Connector Electrical Apparatus 600-30 GENERAL The Cooper Power Systems 600 A, 15/25 kv Class BOL-T Deadbreak Connector is used to terminate

More information

35-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

35-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp Page 1 2018 Grounded Metal Equipment Plate Equipment Connection Bus Bar or Other Component 35 kv Separable Insulated Connector (elbow) Grounded Metal Equipment Plate Equipment Connection Bus Bar or Other

More information

3M Cold Shrink QS-III Inline Splice Kits 15 kv 5513A, 5514A, 5515A and 5516A

3M Cold Shrink QS-III Inline Splice Kits 15 kv 5513A, 5514A, 5515A and 5516A 3M Cold Shrink QS-III Inline Splice Kits 15 kv Data Sheet June 2014! CAUTION Working around energized high-voltage systems may cause serious injury or death. Installation should be performed by personnel

More information

QS-III. 5513A, 5514A, 5515A and 5516A 15 kv Cold Shrink Inline Splice Kits. Data Sheet CAUTION. 1. Product Description. 2. Applications.

QS-III. 5513A, 5514A, 5515A and 5516A 15 kv Cold Shrink Inline Splice Kits. Data Sheet CAUTION. 1. Product Description. 2. Applications. QS-III 5513A, 5514A, 5515A and 5516A 15 kv Cold Shrink Inline Splice Kits Data Sheet Tape Shield Wire Shield UniShield Kit Contents: 1 Cold Shrink Silicone Rubber Splice Body 1 Cold Shrink Adapter Tube

More information

ACCESSORIES FOR LPOF, HPPT AND XLPE HIGH VOLTAGE CABLE SYSTEMS PRODUCT CATALOGUE

ACCESSORIES FOR LPOF, HPPT AND XLPE HIGH VOLTAGE CABLE SYSTEMS PRODUCT CATALOGUE ACCESSORIES FOR LPOF, HPPT AND XLPE HIGH VOLTAGE CABLE SYSTEMS PRODUCT CATALOGUE hvgrid-tech designs and manufactures high voltage cable accessories for all types of cable systems, ranging from 69 kv to

More information

200 A 25 kv and 28 kv class loadbreak elbow connector with optional integral jacket seal-canadian Edition

200 A 25 kv and 28 kv class loadbreak elbow connector with optional integral jacket seal-canadian Edition Loadbreak Connector CA650099EN Supersedes 500-28-7C November 2011 COOPER POWER SERIES 200 A 25 kv and 28 kv class loadbreak elbow connector with optional integral jacket seal-canadian Edition General Eaton

More information

35-kV 200-kV BIL Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

35-kV 200-kV BIL Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp Page 1 2018 Grounded Metal Equipment Plate Equipment Connection 35 kv Separable Insulated Connector (elbow) Bus Bar or Other Component Grounded Metal Equipment Plate Equipment Connection Bus Bar or Other

More information

200 A 15 kv class loadbreak elbow connector with optional integral jacket seal

200 A 15 kv class loadbreak elbow connector with optional integral jacket seal Loadbreak Connectors Catalog Data CA650062EN Supersedes June 2015 COOPER POWER SERIES 200 A 15 kv class loadbreak elbow connector with optional integral jacket seal General Eaton s Cooper Power series

More information

3M Cold Shrink 3-Conductor Inline Splice Kits QS-III 5786A- MT, 5787A-MT and 5788A-MT 25/28 kv for use with Armored and Non- Armored 3/C Cable

3M Cold Shrink 3-Conductor Inline Splice Kits QS-III 5786A- MT, 5787A-MT and 5788A-MT 25/28 kv for use with Armored and Non- Armored 3/C Cable 3M Cold Shrink 3-Conductor Inline Splice Kits QS-III 5786A- MT, 5787A-MT and 5788A-MT 25/28 kv for use with Armored and Non- Armored 3/C Cable Data Sheet September 2010 Description 3M Cold Shrink 3-Conductor

More information

200 A 15 kv class loadbreak elbow connector with optional integral jacket seal-canadian Edition

200 A 15 kv class loadbreak elbow connector with optional integral jacket seal-canadian Edition Loadbreak Connectors Catalog Data CA650063EN Supersedes 500-10-7C November 2011 COOPER POWER SERIES 200 A 15 kv class loadbreak elbow connector with optional integral jacket seal-canadian Edition General

More information

INSTALLATION PRODUCTION TESTS

INSTALLATION PRODUCTION TESTS Deadbreak Apparatus Connectors 600 A 15/25 kv Class Bol-T Deadbreak Connector Electrical Apparatus 600-10 GENERAL The Cooper Power Systems 600 A, 15/25 kv Class Bol-T Deadbreak Connector is used to terminate

More information

QTII (X) Series Silicone Rubber Cold Shrink Termination Kits

QTII (X) Series Silicone Rubber Cold Shrink Termination Kits QTII (X) Series Silicone Rubber Cold Shrink Termination Kits For MV Armored/Non-Armored Cables up to 36kV DATA SHEET Update: August 2006 1. Product Description The 3M QTII (X) Series are Silicone Rubber

More information

Grounding equipment COOPER POWER SERIES. Temporary Connections CA325004EN. Contents

Grounding equipment COOPER POWER SERIES. Temporary Connections CA325004EN. Contents Temporary Connections CA325004EN Supersedes November 2016 Grounding equipment COOPER POWER SERIES Contents Description Page Grounding elbow products... 2 Grounding elbow and kit product ratings... 5 200

More information

3 Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8 Series

3 Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8 Series 3 Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8 Series Data Sheet 1. Product Description 3M Cold Shrink Termination Kit QT-III 7672-S-8 Series contains one silicone rubber termination

More information

Branch Splice QS-2001B

Branch Splice QS-2001B Branch Splice QS-2001B Data Sheet 1. Product Description The 3M Branch Splice QS-2001B molded rubber splice kits are designed to connect extruded dielectric power cables rated 15 kv. The basic kits handle

More information

Type L Cutouts. UltraSIL Polymer-Insulated and Porcelain Type L Open Distribution Cutout. Description

Type L Cutouts. UltraSIL Polymer-Insulated and Porcelain Type L Open Distribution Cutout. Description Type L Cutouts UltraSIL Polymer-Insulated and Porcelain Type L Open Distribution Cutout Electrical Apparatus 327-30 Description Cooper Power Systems has set a new standard of excellence for polymer distribution

More information

3M Cold Shrink 1/C Transition Splice Kit QS-III, 5510A-1T-PILC Series

3M Cold Shrink 1/C Transition Splice Kit QS-III, 5510A-1T-PILC Series 3M Cold Shrink 1/C Transition Splice Kit QS-III, 5510A-1T-PILC Series Data Sheet March 2011 Description 3M Cold Shrink 1/C Transition Splice Kits QS-III, 5510A-1T-PILC Series (which includes 5513A-1T-PILC,

More information

600A Deadbreak Elbow. K656LR Elbow Connector (with Test Point) Features:

600A Deadbreak Elbow. K656LR Elbow Connector (with Test Point) Features: Issue Date: 07/17/2017 Page: 1 of 5 PSS- K656LR Elbow Connector (with Test ) Applications: The Elastimold K656LR (with test point) is designed to provide fully shielded, dead-front submersible cable connections

More information

MEDIUM VOLTAGE TERMINATIONS

MEDIUM VOLTAGE TERMINATIONS CAT010509- Rev 1. 2009 INERTIA- REPL INC. All rights reserved Printed January 2009 MEDIUM VOLTAGE TERMINATIONS General Information about Heat-shrinkable Terminations 3.00 T50NS Terminations for 5-8 kv,

More information

Cold Shrink QS T Trifurcating Transition Splice Kit

Cold Shrink QS T Trifurcating Transition Splice Kit Cold Shrink QS2012-13-3T Trifurcating Transition Splice Kit Instructions IEEE Std. 404-1993 15 kv Class 110 kv BIL Completed Splice Cable Size Range Requirements PILC 500 kcmil Conductor Size (240 mm 2

More information

25 kv class fused loadbreak elbow connector

25 kv class fused loadbreak elbow connector Loadbreak Connectors Catalog Data CA650070EN Supersedes 500-111 July 2012 COOPER POWER SERIES 25 kv class fused loadbreak elbow connector General Eaton combines a fully-shielded and insulated plug-in termination

More information

Tests are conducted in accordance with IEEE Standard 386. ac 60 Hz 1 Minute Withstand 50

Tests are conducted in accordance with IEEE Standard 386. ac 60 Hz 1 Minute Withstand 50 Deadbreak Apparatus Connectors 600 A 35 kv Class Bol-T Deadbreak Connector Electrical Apparatus 600-50 General The Cooper Power Systems 600 A, 35 kv Class Bol-T Deadbreak Connector is used to terminate

More information

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) 1800 24kV to 550kV up to 5000A IEC 60137-2008 Features If you need any transformer bushing proven in operation conditions around the world, Trench

More information

TYPE BLT DISCONNECT SWITCHES

TYPE BLT DISCONNECT SWITCHES TYPE BLT DISCONNECT SWITCHES OUTDOOR-HOOK OPERATED 8.3KV through 38KV A & A Current Furnished with hooks for loadbreak tool REA/RUS approved S M C O 1 BLT PARALLEL BLADE DISTRIBUTION CLASS DISCONNECT SWITCH

More information

600 A 35 kv class BT-TAP deadbreak connector

600 A 35 kv class BT-TAP deadbreak connector Supersedes 600-55 July 2014 600 A 35 kv class BT-TAP deadbreak connector General Eaton's Cooper Power Systems 600 A 35 kv Class BT-TAP deadbreak connector is used to terminate high-voltage underground

More information

Medium Voltage. Joints & Terminations

Medium Voltage. Joints & Terminations 57 - Cold Shrink Joints Supporting Core Radially shrinkable elastomeric splice Semi-conductive layer High permitivity insulation layer 6.6/11/(12) kv 3M QS1000 is a one-piece cold shrink joint body manufactured

More information

11. CABLE SPECIFICATIONS 5kV, 15kV, AND 35kV RUBBER OR PLASTIC INSULATED CABLE

11. CABLE SPECIFICATIONS 5kV, 15kV, AND 35kV RUBBER OR PLASTIC INSULATED CABLE 11. CABLE SPECIFICATIONS 5kV, 15kV, AND 35kV RUBBER OR PLASTIC INSULATED CABLE 11.1 GENERAL Only single conductor cables as described in this section are acceptable for connection to PECO Energy Company

More information

M-Force three-phase switch

M-Force three-phase switch Supersedes K-SEC 926 December 2012 M-Force three-phase switch Description The M-Force switch from Eaton's Cooper Power Systems is a distribution-class, gangoperated, factory unitized three-phase overhead

More information

Solid Dielectric, Three Phase Reclosers CATALOG VS11

Solid Dielectric, Three Phase Reclosers CATALOG VS11 Solid Dielectric, Three Phase Reclosers Providing electronic, three phase overcurrent protection for systems rated through 38kV, 800A continuous current, 12.5kA symmetrical interrupting Reliable performance

More information

Cold Shrink QS2013-3T-WS Trifurcating Transition Splice Kit

Cold Shrink QS2013-3T-WS Trifurcating Transition Splice Kit Cold Shrink QS2013-3T-WS Trifurcating Transition Splice Kit Instructions for Shielded and Belted PILC Cable IEEE Std. 404-1993 15 kv Class 110 kv BIL Completed Splice UniShield Wire Shielded Longitudinally

More information

3M Cold Shrink QT-III Silicone Rubber 3/C Cabinet Mount Termination Kit

3M Cold Shrink QT-III Silicone Rubber 3/C Cabinet Mount Termination Kit 3M Cold Shrink QT-III Silicone Rubber 3/C Cabinet Mount Termination Kit With High-K Stress Relief For 3-Conductor Copper Tape Shield Cables with or without Ground Wires 7600-T-3RJS Series Instructions

More information

600 A 15 kv class T-OP II deadbreak connector

600 A 15 kv class T-OP II deadbreak connector Deadbreak Apparatus Connectors CA650017EN Supersedes 600-12 February 2010 COOPER POWER SERIES 600 A 15 kv class T-OP II deadbreak connector General Eaton terminates high-voltage underground cable to transformers,

More information

Cold Shrink Silicone Rubber Termination Kit QT-III 7620-S, 7690-S and 7680-S Series kv

Cold Shrink Silicone Rubber Termination Kit QT-III 7620-S, 7690-S and 7680-S Series kv Cold Shrink Silicone Rubber Termination Kit QT-III 7620-S, 7690-S and 7680-S Series 5-34.5 kv Data Sheet 1.0 Product Description 3M Cold Shrink Silicone Rubber Termination Kit QT- III 7620-S, 7690-S and

More information

HUBBELL Type M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary

HUBBELL Type M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary Catalog 14B January 2015 HUBBELL Type M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary Application The Chance Type M3 Disconnect Switch is a single-phase hookstick operated switch.

More information

Surge Arresters. UltraSIL Polymer-Housed Evolution (10 ka) Surge Arresters. General. Construction. features

Surge Arresters. UltraSIL Polymer-Housed Evolution (10 ka) Surge Arresters. General. Construction. features Surge s Electrical Apparatus 235-99 General Cooper Power Systems set the standard for design, manufacturing and delivery of polymeric distribution arresters with the UltraSIL polymerhoused arrester family.

More information

M-Force three-phase switch

M-Force three-phase switch Switches and Disconnects CA008004EN Supersedes May 2015 COOPER POWER SERIES M-Force three-phase switch Description Eaton's Cooper Power series M-Force switch is a distribution-class, gang-operated, factory

More information

Transformer High Current Bushings Type CFPT & CFCT 36kV up to 40kA IEC

Transformer High Current Bushings Type CFPT & CFCT 36kV up to 40kA IEC Transformer High Current Bushings Type CFPT & CFCT 36kV up to 40kA IEC 60137-2008 High current bushings for transformer Features Bushing Type CFPT version Porcelain Insulator Trench RIG technology for

More information

600 A 15 and 25 kv class Cleer grounding elbow

600 A 15 and 25 kv class Cleer grounding elbow Loadbreak/Deadbreak Connectors CA650013EN Supersedes March 2015 COOPER POWER SERIES 600 A 15 and 25 kv class Cleer grounding elbow General Eaton provides a visible ground on its Cooper Power series 600

More information

copper stud. If a 900 A rating is desired, specify a C as the 8th digit when determining your part number (See Table 3, page 3.)

copper stud. If a 900 A rating is desired, specify a C as the 8th digit when determining your part number (See Table 3, page 3.) Molded Rub ber Products 600 A 35 kv Class Separable Splices Electrical Ap pa ra tus 700-31 General Cooper Power Systems 600 A, 35 kv Class Deadbreak Separable Splices are used to splice two, three or four

More information

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) 1800 24kV to 550kV up to 5000A IEC 60137-2008 Features If you need any transformer bushing proven in operation conditions around the world, Trench

More information

IEC Separable Connectors 36 kv and 42 kv, 630A and 1250A Front T-Body / Coupling (Rear) T-Body Connector

IEC Separable Connectors 36 kv and 42 kv, 630A and 1250A Front T-Body / Coupling (Rear) T-Body Connector www.chardongroup.com IEC Separable Connectors 36 kv and 42 kv, 630A and 1250A Front T-Body / Coupling (Rear) T-Body Connector Application Chardon Front T-Body / Coupling (Rear) T-Body connectors are fully

More information

UltraSIL polymer-insulated and porcelain loadbreak Type LB open distribution cutout

UltraSIL polymer-insulated and porcelain loadbreak Type LB open distribution cutout Fusing Equipment Catalog Data CA132035EN Supersedes November 2015 COOPER POWER SERIES UltraSIL polymer-insulated and porcelain loadbreak Type LB open distribution cutout Description Eaton has set a standard

More information

3M Cold Shrink Splice Kits, QS T Series

3M Cold Shrink Splice Kits, QS T Series 3M Cold Shrink Splice Kits, QS-2000-3T Series For 15 kv Trifurcating Transition Splice Kits Data Sheet October 2011 Description 3M Cold Shrink Splice Kits, QS-2000-3T Series for 15 kv Trifurcating Transition

More information

Polymer Insulators A Better Solution

Polymer Insulators A Better Solution Polymer Insulators A Better Solution October 2016 LET S CONNECT POLYMER INSULATORS Design derived from PLP s many years of worldwide experience and tested to adhere to ANSI C29.5 and ANSI 29.6 insulator

More information

11. CABLE SPECIFICATIONS 5kV, 15kV, AND 35kV RUBBER OR PLASTIC INSULATED CABLE

11. CABLE SPECIFICATIONS 5kV, 15kV, AND 35kV RUBBER OR PLASTIC INSULATED CABLE 11. CABLE SPECIFICATIONS 5kV, 15kV, AND 35kV RUBBER OR PLASTIC INSULATED CABLE 11.1 GENERAL Only single conductor cables as described in this section are acceptable for connection to PECO Energy Company

More information

Composite Insulators Suspensions Line Posts Brace Posts Station Posts

Composite Insulators Suspensions Line Posts Brace Posts Station Posts Composite Insulators Suspensions Line Posts Brace Posts Station Posts Quality, reliability and consistency for over four decades As an alternative and complement to our range of proven ceramic insulators,

More information

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide 1ZSE 2750-112 EN, REV. 4 Wall bushings type GSA-AA Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.

More information

Installation Instructions

Installation Instructions 517 Lyons Ave, Irvington, NJ 07111 Phone: 973-371-1771 Fax: 973-371-4304 Installation Instructions Deadbreak Elbow Applicable Current Ratings 600A (Aluminum) 900A (Copper) Applicable Catalog Prefix 35kV

More information

3M Cold Shrink QT-III Silicone Rubber Three-Core Termination Kits

3M Cold Shrink QT-III Silicone Rubber Three-Core Termination Kits 3M Cold Shrink QT-III Silicone Rubber Three-Core Termination Kits With High-K Stress Relief For 3-Conductor Type G (Ground Wire), Copper Tape Shield, Armored Cables 7600-S-3G Series Instructions IEEE Std.

More information

Kuhlman Electric Corporation Volt Instrument Transformers

Kuhlman Electric Corporation Volt Instrument Transformers Kuhlman Electric Corporation 34500 Volt Instrument Transformers 34500 Volt Table of Contents Description Model Page Wound, Dry-Type VT Y (High Accuracy available) PTT-200-9710(H) 3-4 Wound, Oil-Filled

More information

600 A 35 kv class separable splices

600 A 35 kv class separable splices Splices Catalog Data CA650050EN Supersedes 700-31 March 2009 COOPER POWER SERIES General Eaton s Cooper Power series 600 A, 35 kv Class deadbreak separable splices are used to splice two, three or four

More information

Cobra-S. Catalog Cobra-S

Cobra-S. Catalog Cobra-S Cobra-S Solid Dielectric, Three Phase Reclosers Providing electronic three phase overcurrent protection for systems rated through 38kV, 800A continuous current, 12.5/16kA symmetrical interrupting Control

More information

PRODUCT CATALOGUE. Overhead System

PRODUCT CATALOGUE. Overhead System PRODUCT CATALOGUE Overhead System Information Tel : 03-4777547 Fax : 03-4777570 E-mail : overseas@jaker.com.tw Web : www.jaker.com.tw Add : No.787, Xinwen Rd. Xinwu Dist., Taoyuan City 327, Taiwan Contents

More information

GROUP D. Switch & Protective device.

GROUP D. Switch & Protective device. GROUP D Switch & Protective device PYUNGIL Bldg., 147-10, Gwanyang 2-dong, Dongan-gu, Anyang-si, Gyeonggi-do, 431-808, Korea Tel : 82-31-420-0~3 FAX : 82-31-424-7300 www.pyungil.com Pole-mounted SF Insulated

More information

IEC Separable Connectors 17.5 kv/24 kv, 630A

IEC Separable Connectors 17.5 kv/24 kv, 630A IEC Separable Connectors 17.5 kv/24 kv, 630A Front T-Body / Coupling (Rear) T-Body Connector Application The Chardon T-Body connectors are used to terminate polymeric cable to dead front apparatus such

More information

Jumpering and grounding equipment and assemblies

Jumpering and grounding equipment and assemblies Supersedes 325-50 July 2014 Jumpering and grounding equipment and assemblies Contents Description Page Jumpering Equipment Load Pickup Clamps... 2 Jumper Clamps.... 3 Jumper Components.... 4 C-Type Grounding

More information

PNO Condenser Bushings from 52 kv to 420 kv Oil-to-air - Oil-Impregnated Paper

PNO Condenser Bushings from 52 kv to 420 kv Oil-to-air - Oil-Impregnated Paper GE Grid Solutions PNO Condenser Bushings from 52 kv to 420 kv Oil-to-air - Oil-Impregnated Paper PNO bushings are capacitance graded bushings with an oil impregnated paper core. PNO bushings are conform

More information

Surge Arresters. UltraSIL Polymer-Housed VariSTAR Surge Arresters: Normal-Duty (5 ka), Heavy-Duty (10 ka), and Heavy-Duty Riser Pole (10 ka)

Surge Arresters. UltraSIL Polymer-Housed VariSTAR Surge Arresters: Normal-Duty (5 ka), Heavy-Duty (10 ka), and Heavy-Duty Riser Pole (10 ka) Surge s UltraSIL Polymer-Housed VariSTAR Surge s: Normal-Duty (5 ka), Heavy-Duty (10 ka), and Heavy-Duty Riser Pole (10 ka) Electrical Apparatus 235-35 General Cooper Power Systems has set the standard

More information

600 A 25 kv class BT-TAP deadbreak connector

600 A 25 kv class BT-TAP deadbreak connector Deadbreak Connectors Catalog Data CA650001EN Supersedes January 2015 600 A 25 kv class BT-TAP deadbreak connector COOPER POWER SERIES General Eaton terminates high-voltage underground cable to transformers,

More information

3M Cold Shrink Silicone Rubber Termination QT-III 7600-S-3G Series Three-Core Outdoor Termination

3M Cold Shrink Silicone Rubber Termination QT-III 7600-S-3G Series Three-Core Outdoor Termination 3M Cold Shrink Silicone Rubber Termination QT-III 7600-S-3G Series Three-Core Outdoor Termination Instructions IEEE Std. No. 48 Class 1 Termination CAUTION Working around energized electrical systems may

More information

4 AWG to 2000 kcmil at 15 kv, 2 AWG to 1750 kcmil at 25 kv and 1 AWG to 1500 kcmil at 34.5 kv. Stress Control

4 AWG to 2000 kcmil at 15 kv, 2 AWG to 1750 kcmil at 25 kv and 1 AWG to 1500 kcmil at 34.5 kv. Stress Control Quick Term II 5640 and 5650 Series Silicone Rubber Termination Kits Data Sheet ÄÄÄÄ ÄÄÄ Ä ÄÄÄ Ä 15 kv 34.5 kv 1. Product Description 3M 5640 and 5650 Series Quick Term II Silicone Rubber Termination Kits

More information

Jumpers & Load Pickup Tools

Jumpers & Load Pickup Tools Jumpers & Load Pickup Tools Catalog 2300 May 2016 Jumpers & Load Pickup Tools 2300 May 2016 Page 2301 All Chance Insulated Jumpers meet ASTM F 2321 Standard Specification. G4758 15kV 5 5 / 8 " G4765 25kV

More information

SUBMERSIBLE SECONDARY CONNECTORS SSBC350-4LI. Cond. Range H W L

SUBMERSIBLE SECONDARY CONNECTORS SSBC350-4LI. Cond. Range H W L SUBMERSIBLE SECONDARY CONNECTORS -1- Index TYPE SSBC350-L (Wide-Port Spacing) Rubber Insulated Secondary Connectors SURE-SEAL RUS Approved User friendly wide-port spacing (50% more room for cable training).

More information

High Voltage Copper, Smooth Aluminum Shield/Sheath

High Voltage Copper, Smooth Aluminum Shield/Sheath High Voltage Copper, Smooth Aluminum Shield/Sheath XLPE Insulation, HDPE Jacket, 69 kv - 138 kv Features True triple vertical extrusion system for optimum insulation concentricity, and excellent electric

More information

Honeywell Salisbury Outage Protection. Bushing Covers, Conductor Covers, Instant Insulation

Honeywell Salisbury Outage Protection. Bushing Covers, Conductor Covers, Instant Insulation Honeywell Salisbury Outage Protection Bushing Covers, Conductor Covers, Instant Insulation Why You Should Use Outage Protection The cost of animal caused outages to the utilities is preventable. Animals

More information

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide 1ZSE 2750-106 EN, REV. 7 Oil SF 6 bushings type GOEK Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.

More information

Raychem CSJA Safety Instructions. Safety Instructions. Customer Service. Kit Contents. Installation Instructions

Raychem CSJA Safety Instructions. Safety Instructions. Customer Service. Kit Contents. Installation Instructions Raychem CSJA 1521 Cold-Shrinkable Splice for single core polymeric insulated (XLPE-EPR) cables up to 15kV for tape, wire, Unishield, LC shield, JCN, and flat strap neutral cable UniShield is a trademark

More information

3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8-Tape/LC

3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8-Tape/LC 3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8-Tape/LC For Tape Shield or Longitudinally Corrugated (LC) Shielded Cable Instructions IEEE Std. No. 48-1996 Class 1 Termination 69 kv Class, 350

More information

34-SDMS-01 SPECIFICATIONS FOR

34-SDMS-01 SPECIFICATIONS FOR SPECIFICATIONS FOR M V DROPOUT FUSE CUT OUTS This specification is property of SEC and subject to change or modification without any notice CONTENTS C l a u s e s: Page No. 1- SCOPE 3 2- CROSS REFERENCES

More information

A 1.2 kv class externally removable secondary bushing

A 1.2 kv class externally removable secondary bushing OEM Equipment Catalog Data CA800018EN Supersedes July 2015 COOPER POWER SERIES 3010-4515 A 1.2 kv class externally removable secondary bushing General Eaton s Cooper Power series 3010-4515 A externally

More information

3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8(S)-JCN

3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8(S)-JCN 3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8(S)-JCN For Jacketed Concentric Neutral (JCN) Cable Instructions IEEE Std. No. 48-1996 Class 1 Termination 69 kv Class, 350 kv BIL IEC 60840 72,5

More information

Solid Dielectric, Single Phase Reclosers

Solid Dielectric, Single Phase Reclosers Solid Dielectric, Single Phase Reclosers Providing electronic overcurrent protection for single phase operation on systems rated through 38kV, 800A continuous current,12.5ka symmetrical interrupting Reliable

More information

ELB ES. Product Installation Instructions

ELB ES. Product Installation Instructions ELB-25-210-ES 200A 25kV Class Loadbreak Elbow with Integral Jacket Seal for Copper Tape (CT) and Jacketed Concentric Neutral (JCN) cables Product Installation Instructions Safety Instructions When installing

More information

UNDERGROUND TRANSMISSION SOLUTIONS

UNDERGROUND TRANSMISSION SOLUTIONS UNDERGROUND TRANSMISSION SOLUTIONS PRODUCT CATALOG SWC002-6_UndergroundTransmissionCatalog_R.indd SOUTHWIRE SOLUTIONS FOR UNDERGROUND TRANSMISSION CABLES XLPE Cables 69 through 400 kv with Copper and Aluminum

More information

Completing the picture

Completing the picture HIGH VoltaGe cable accessories for 72 kv up to 170 kv Completing the picture based on experience is the future nkt cables GmbH nkt was established in 1891 as cable manufacturer. in 1999 nkt a/s denmark

More information

Disconnect & ByPass Switches

Disconnect & ByPass Switches Disconnect & ByPass Switches Disconnect & Oil Circuit Recloser Bypass Switches; Regulator & Current Transformer Bypass Switches Electrical Apparatus K-SEC 060 & 090 Contents Type D-73 Distribution Class

More information

Product Specifications for Aluminum Vertical Break Switches

Product Specifications for Aluminum Vertical Break Switches 1. General a) This specification covers the design, manufacture, and shipment of aluminum vertical break switches, both air-break and load-break configurations, for substation and transmission switching

More information

3M Cold Shrink QT-III Silicone Rubber Termination

3M Cold Shrink QT-III Silicone Rubber Termination 3M Cold Shrink QT-III Silicone Rubber Termination For Tape-Over-Wire (TOW) or Wire-Over-Tape (WOT) Shielded Cable 7673-S-8(S)-TOW/WOT Instructions IEEE Std. No. 48 Class 1 Termination 69 kv Class, 350

More information

Product Number

Product Number Sealing and Grounding Cold Shrink cable accessory sealing kits are designed to seal the end of JCN cable. Use these kits when installing elbows or other cable accessories that do not include a jacket seal.

More information

16kA Solid Dielectric, Triple Option Reclosers Catalog VLT12

16kA Solid Dielectric, Triple Option Reclosers Catalog VLT12 16kA Solid Dielectric, Triple Option Reclosers Providing electronic overcurrent protection for single or three phase operation on systems rated through 27kV, 630A continuous current, 16kA symmetrical interrupting

More information

Surge Arresters. UltraSIL Housed VariSTAR Station Class Surge Arresters GENERAL CONSTRUCTION

Surge Arresters. UltraSIL Housed VariSTAR Station Class Surge Arresters GENERAL CONSTRUCTION Surge Arresters UltraSIL Housed VariSTAR Station Class Surge Arresters Electrical Apparatus 235-88 GENERAL Cooper Power Systems has set a new standard of excellence for polymerhoused station class surge

More information

3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8-TOW/WOT

3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8-TOW/WOT 3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8-TOW/WOT For Tape-Over-Wire (TOW) or Wire-Over-Tape (WOT) Shielded Cable Instructions IEEE Std. No. 48-1996 Class 1 Termination 69 kv Class, 350

More information

Solid Dielectric, Single Phase Recloser

Solid Dielectric, Single Phase Recloser Solid Dielectric, Single Phase Recloser Catalog O-vsp17 Viper-SP Viper-SP solid dielectric, single phase recloser combines the time-proven reliability of electronically controlled, vacuum fault interrupters

More information